1 Instruction Manual Microprocessor-based Thermocouple Thermometers 9353 K-THERMOCOUPLE THERMOMETER MR ins rum n s MEM- These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with the directives EN and EN TABLE OF CTENTS Preliminary Examination... 3 General Description... 3 Functional Description and Specifications of Functional Description and Specifications of Functional Description and Specifications for Functional Description and Specifications of Functional Description and Specifications of Functional Description and Specifications of Functional Description and Specifications of Operational Guide... Display Codes Guide... 9 Replacement... 0 Calibration... 0 Shockproof Rubber Boots... Accessories... Warranty... 6 CE Declaration of Conformity... 7
2 3 4 PRELIMINARY EXAMINATI Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. If noticeable damage is evident, notify your Dealer. Each thermometer comes supplied with a 9V battery and instruction manual. Note: Save all packing material until you are sure that the instrument functions correctly. All defective items must be returned in the original packing together with the supplied accessories. GENERAL DESCRIPTI 93530, 9353, 9353, and allow temperature measurement using interchangeable K-type thermocouple probes allows temperature measurements with different types of thermocouples (K - J - T). This meter is equipped with a key that switches range from K-type to J-type or T-type thermocouples and are specifically designed for the food industry allows temperature measurement using interchangeable T-type thermocouple probes uses a fixed K-type penetration temperature probe ( 766C) with m (3.3') cable. The non-linearity of the temperature probe is linearized by the built-in microprocessor, in order to achieve high degree accuracy and resolution. It also permits accurate compensation for drifts in the measurement circuit and the reference junction has two built-in K-type probe connectors. By simply pressing a button, the meter switches between the two readings on the display. A " T" button will display the difference between the two probe readings. Standard features include: Interchangeable probes (except ) Clear Liquid Crystal Display Two year Warranty Possibility of switching between the Centigrade and the Fahrenheit scale (for 93530, 9353, 9355, , only) function that freezes the reading on the display (for 93530, 9355 and only) - memory recall function (for 9353, 9355 and only) Low battery detection. All these functions are easily accessible through the keypad. Self-explanatory symbols are used to remind the user of the operating mode or condition. Hanna manufactures several K-type thermocouple probes for different applications. See pages -5 for more details. 3 4
3 5 6 FUNCTIAL DESCRIPTI AND SPECIFICATIS OF FUNCTIAL DESCRIPTI AND SPECIFICATIS OF 9353 ins rum n s ins rum n s K K K-THERMOCOUPLE THERMOMETER K-THERMOCOUPLE THERMOMETER RANGE: -00 to to MR 3 6 MEM Liquid Crystal Display. / Key 3. Reading Hold Key 4. Measuring Scale Key ( or ). Specifications Range to to 500 Resolution 0. (-00.0 to 999.9) (000 to 370) 0. ( to 999.9) (000 to 500) Accuracy ±0.% F.S. for one year, excluding probe error Typical EMC ±3 Deviation ±6 Probe K-thermocouple (optional) (see pages -5) 9V/00 hours of continuous use Environment 0 to 50 (3 to ); 95% RH Dimensions 43x80x38mm (5.6x3.x.5") Weight 30 g (.3 oz.) 5. Liquid Crystal Display. / Key 3. Reading Memory / Hold Key 4. Measuring Scale Key ( or ) 5. Minimum Temperature Recalling Key 6. Maximum Temperature Recalling Key 7. Memory Recalling Key. Specifications Range to to 500 Resolution 0. (-00.0 to 999.9) (000 to 370) 0. ( to 999.9) (000 to 500) Accuracy ±0.% F.S. for one year, excluding probe error Typical EMC ±3 Deviation ±6 Probe K-thermocouple (optional) (see pages -5) 9V/00 hrs of continuous use Environment 0 to 50 (3 to ); 95% RH Dimensions 43x80x38mm (5.6x3.x.5") Weight 30 g (.3 oz.) 6
4 7 8 FUNCTIAL DESCRIPTI AND SPECIFICATIS FOR 9353 FUNCTIAL DESCRIPTI AND SPECIFICATIS OF 9355 ins rum n s ins rum n s K J K-THERMOCOUPLE THERMOMETER (DUAL INPUT) K-THERMOCOUPLE THERMOMETER 7 MR 7 6 T MEM T T KJT Liquid Crystal Display. / Key 3. Reading Memory/Hold Key 4. Measurement Resolution Key (0. or ) 5. Input Probe Selection Key (T or T) 6. Temperatures Difference Key 7. Memory Recalling Key. Specifications Range to 370 Resolution Accuracy Typical EMC Deviation Probe Environment Dimensions Weight 0. (-00.0 to 999.9) (000 to 370) ±0.% F.S. for one year, excluding probe error ±3 ±6 K-thermocouple (optional) (see pages -5) 9V/00 hrs of continuous use 0 to 50 (3 to ); 95% RH 43x80x38mm (5.6x3.x.5") 7 30 g (.3 oz.). Liquid Crystal Display. / Key 3. Reading Memory/Hold Key 4. Thermocouple Type Selection Key (K or J or T) 5. Minimum Temperature Recalling Key 6. Maximum Temperature Recalling Key 7. Measuring Scale key ( or ). Specifications Range K to 370 / to 500 J to / to 650 T to / to Resolution 0. (up to 999.9) 0.(up to 999.9) (over 000) (over 000) Accuracy K= ±0.% F.S. J = ±0.% F.S. T = ±0.5% F.S. for one year, excluding probe error Typical EMC ±3 Deviation ±6 Probe K, J and T thermocouple(optional) (for K-thermocouple see pages -5) 9V/00 hrs of continuous use Environment 0 to 50 (3 to ); 95% RH Dimensions 43x80x38mm (5.6x3.x.5") Weight 30 g (.3 oz.) 8
5 9 0 FUNCTIAL DESCRIPTI AND SPECIFICATIS OF FUNCTIAL DESCRIPTI AND SPECIFICATIS OF ins rum n s ins rum n s K-THERMOCOUPLE THERMOMETER RANGE: to CLEAR RANGE: -50 to Foodcare. Liquid Crystal Display. / Key 3. Reading Hold Key 4. Measuring Scale Key ( or ) 5. Minimum Temperature Recalling Key 6. Maximum Temperature Recalling Key 7. / Temperature erasing key. Specifications Range to 50.0 / -50 to to 30.0 / -58 to 74 Resolution 0. (-50.0 to 50.0) (-50 to 950) 0. (-58.0 to 30.0) (-58 to 74) Accuracy ±0.% for one year, excluding probe error Typical EMC ±3 Deviation ±6 Probe K-thermocouple (optional) (see pages -5) 9V/500 hrs of continuous use Environment 0 to 50 (3 to ); 95% RH Dimensions 43x80x38mm (5.6x3.x.5") Weight 30 g (.3 oz.) 9. Liquid Crystal Display. / Key. Range 0 Specifications to 0.0 to 400 Resolution 0. (-50 to 0) (0 to 400) Accuracy ±0.3% for one year, excluding probe error Typical EMC ±3 Deviation Probe T-thermocouple (optional) 9V/500 hrs of continuous use Environment 0 to 50 (3 to ); 95% RH Dimensions 43x80x38mm (5.6x3.x.5") Weight 30 g (.3 oz.)
6 FUNCTIAL DESCRIPTI AND SPECIFICATIS OF OPERATIAL GUIDE INITIAL PREPARATI Remove the battery cover on the rear of your thermometer, unwrap the battery and connect it to the clip. Insert the battery in its compartment and replace the cover. 9 VOLT BATTERY Compartment SLIDE To switch on, press / on the front of the unit.. Liquid Crystal Display. / Key 3. Measuring Scale Key ( or ). Specifications Range to 50.0 / -50 to to 30.0 / -58 to 74 Resolution 0. (-50.0 to 50.0) (-50 to 950) 0. (-58.0 to 30.0) (-58 to 74) Accuracy ±0.% for one year, excluding probe error Typical EMC ±3 Deviation ±6 Probe 766C K-thermocouple (included) 9V/500 hrs of continuous use Environment 0 to 50 (3 to ); 95% RH Dimensions 43x80x38mm (5.6x3.x.5") Weight 30 g (.3 oz.) Your thermometer will carry ºC out a self diagnostic test. The ºF BAT LCD shows all the segments K J T at once, to make sure none is missing. After the test, the thermometer will switch to the measurement mode. If a temperature probe is plugged in, the unit will display the temperature. For 93530, 9353, 9353, 9355 If the probe is not plugged in, the display will show "----". For and If the probe is not plugged in, the display will show "Er". To switch your thermometer off, press / again.
7 3 4 MEASURING SCALE (/)(for 93530, 9353, 9355, , only) When the meter is turned on, it automatically defaults to the scale. Measurements can be performed on either the Centigrade or the Fahrenheit scale. To change the scale, press / once. MODE (for 93530, 9355 and only) The reading hold function is activated by the key. For and 9355 only To freeze the measured temperature on the display, press and hold the key. "" is displayed when this key is pressed. MEASUREMENT RESOLUTI When switched on, 93530, 9353, 9353 and 9355 default to a 0. digit resolution (see specifications). These instruments automatically change the resolution to degree when the measured temperature is higher than (or 0 for ). For and only When switched on, and default to d e g r e e resolution. Press / again to change the resolution to 0. or 0.. As soon as the key is released, the meter returns to the normal operational mode. For only The temperature is frozen on the display until the button is pressed a second time. The blinking symbol "M" appears on the display when is activated. Press again to return to the normal operational mode. - FUNCTI (9353, 9355 and only) Maximum and minimum temperatures are monitored throughout a continuous measuring process. M 3 4
8 5 6 The values may be recalled or cleared at any time during the measurement. Check the highest or lowest measured temperature by pressing the respective or key. The appropriate display indicator, "" or "", will light up together with the value retrieved from memory. Release the key to resume normal operation. MEMORY FUNCTI (9353 and 9353 only) The memory & hold function is activated by MEM. The measured temperature is stored in memory and frozen on the display when this function key is pressed. The memory value will be overridden each time the memory & hold function is activated. A blinking "MEM" on display indicates the operating mode. MEM MEM CLEAR - FUNCTI ( 9353, 9355 and only) By pressing and simultaneously (for 9353 and 9355) or CLEAR (for ) the present measurement reading is assigned to the highest and lowest temperature memories, i.e. both memories have equal temperature reading. The "" and "" display indicators (for only) will blink twice to notify the user that the clearing process is in progress. Press MR to recall previously stored temperature reading. In this mode of operation, the display indicator "MEM" is shown. MR If no data is found, "----" will be displayed. MEM + CLEAR 5 THERMOCOUPLE TYPE SELECTI ( 9355 only) By pressing KJT the user is allowed to set the thermometer according to the connected thermocouple type, and the related symbol will be displayed, i.e.: 6
9 7 8 K for K-Type, J for J-Type, T for T-Type. KJT PROBE INPUT SELECTI ( 9353 only) When switched on, the instrument automatically shows the temperature measured by Probe and a "K" appears K on the LCD display. To view the input temperature of Probe, press T/T and "K" will be displayed. T T K J T K W BATTERY DETECTI When the battery is low the user is prompted by the appearance of the word "BAT" (for 93530, 9353, 9353, 9355) or "Eb" for , and to substitute the battery (see page 0). AUTO-SHUT To save battery life, will switch off after 5 minutes and 93530, 9353, 9353, 9355, and after 60 minutes. The switch located in the battery compartment enables this feature (for all models except of ). Remove the battery cover and slide the switch to the right. The thermometer's auto-off feature will be disabled. If the switch is to the left, the meter will shut off automatically. BAT TEMPERATURE DIFFERENCE (for 9353 only) The difference between the temperature measured by the two probes can be displayed by simply pressing T. A " " will appear on the left-hand of the display to indicate this function. 9 VOLT BATTERY AUTO- SWITCH BATTERY BATTERY COVER T 7 8
10 9 0 Display DISPLAY CODES GUIDE Description 93530, 9353, 9353, 9355: ---- The probe is not connected to the instrument or the reading is out of range BAT Weak battery, needs to be replaced , and : Er Eb The probe is not connected to the instrument or the reading is out of range Weak battery, needs to be replaced 93530, 9353, 9355, , : The instrument is reading in the Centigrade scale The instrument is reading in the Fahrenheit scale 9353, 9355 and : Displays the highest measured temperature Displays the lowest measured temperature and 9355: : Freezes current reading on display M Indicates the value of the temperature frozen on the display 9353 and 9353: Freezes current reading on display and stores MEM the reading into memory MEM Indicates the value of the temperature stored into memory 9353: K or K Temperature at probe or respectively Difference between temperatures at the two probes 9355: K,J or T Thermocouple probe type in use 9 CALIBRATI All Hanna Instruments thermometers have been accurately pre-calibrated at the factory. It is generally recommended to have all thermometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center. BATTERY REPLACEMENT When the battery is low the user is warned by the word "BAT" (for 93530, 9353, 9353, 9355) or "Eb" (for , and ) on the instrument's display. Replace immediately the battery. BAT replacement must only take place in a non hazardous area using a 9V battery. Remove the battery compartment cover on the rear of the meter and replace 9 VOLT BATTERY the 9V battery with a new one. Make sure the battery Compartment contact is tight before replacing the cover. The meter will turn on automatically when a new bat- SLIDE tery is connected. You can turn it off by pressing /. 0
11 SHOCKPROOF RUBBER BOOTS These rubber boots are specially made to prolong the life of your instruments and to prevent damage due to accidental falls. They measure 55 x 90 x 45 mm (6.x3.5x.8") and are available in two different colors: = blue colored = orange colored. Select the proper color according to your preference. ACCESSORIES K-Type Thermocouple Probes with detachable handle & mini-connector (to be plugged into 766HD probe handle): 766PA Roller surface probe, max 30/ PB Surface probe, max 650/00 K MR MEM 766PC Penetration probe, max 900/650 55mm 6." 3mm 0." 766PD Air probe, max 300/570 50mm 9.8" 3mm 0."
12 PE General use probe, max 900/650 55mm 6." 3mm 0." 766B 90 surface probe, max 450/ mm.8" 30mm." 766PE General use probe, max 900/650 00mm 7.8" 5mm 0.0" 766B Surface probe, max 900/650 30mm 5." 8mm 0.3" 766B3 Small surface probe with insulated shaft, max 00/ HD Rugged thermocouple probe handle with m (3.3' ) cable fitted with a miniconnector 30mm 5." 5mm 0." 766C Penetration probe, max 900/650 with integral handle, m cable & miniconnector: 766A Roller surface probe, max 30/ D Air probe, max 300/ B Surface probe, max 650/00 766E General use probe, max 900/
13 E General use probe, max 900/650 WARRANTY 766F High temperature wire probe without handle, max 00/ F Flexible probe without handle, max 480/900 m TV Pipe clamp probe, max 00/ mm 0" 35mm.4".5mm 0.06" mm 0.08" Max. Other accessories: Soft carrying case measuring 50x90x30mm Blue rubber boot measuring 55 x 90 x 45 mm Orange rubber boot measuring 55 x 90 x 45 mm 7003 Rugged carrying case MANK93R3 Instruction manual All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 4 days from the date of purchase. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 6
14 7 8 CE DECLARATI OF CFORMITY PRINTED IN ITALY MANK93R3 04/98 Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. In particular cases the instruments could turn off. In such cases they can be turned on by pressing the / key. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 4VAC or 60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens. h t t p : / / w w w. h a n n a i n s t. c o m 7
HI HI HI HI Portable Microprocessor Thermistor Thermometers
1 2 Instruction Manual HI 93501 - HI 93502 HI 93503 - HI 93510 Portable Microprocessor Thermistor Thermometers LO HI CLEAR F HOLD ins rum n s ON OFF Dear Customer, Thank you for choosing a Hanna product.
More informationHI 8751 HI 8752 HI 8753 Portable Thermistor Thermometers
Instruction Manual HI 8751 HI 8752 HI 8753 Portable Thermistor Thermometers http://www.hannacan.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna
More informationHI HI N HI HI
Instruction Manual HI 935005 - HI 935005N HI 935002 - HI 935009 Portable K-Thermocouple Thermometers www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you
More informationHI HI N HI HI
Instruction Manual HI 935005 - HI 935005N HI 935002 - HI 935009 Portable K-Thermocouple Thermometers w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna product. Please read this
More informationHI8564 HI Portable Thermo-Hygrometers. Instruction Manual. These Instruments are in Compliance with the CE Directives
2... 140 hygrometer ºC 0 to 0 ºF 2 to 140 Instruction Manual HI854 HI 940 Portable Thermo-Hygrometers % ins rum n s e THERMOHYGROMETER % ins rum n s e HI 854 thermo RANGE: 5 to 95 RANGES HI940 ºF ºC ºC
More informationHI ma Simulator
Instruction Manual HI 931002 4-20 ma Simulator http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please
More informationHI ma Simulator
Instruction Manual HI 931002 4-20 ma Simulator http://www.hannacan.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please
More informationHI HI HI HI Portable Microprocessor Printing and Logging PT-100 Thermometers
1 2 Instruction Manual HI 955201 - HI 955202 HI 955301 - HI 955302 Portable Microprocessor Printing and Logging PT-100 Thermometers Dear Customer, Thank you for choosing a Hanna Instruments Product. Please
More informationInstruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.
Instruction Manual HI 9033 HI 9034 Waterproof Multi-Range EC and TDS Meters for Field Applications www.hannainst.com PRELIMINARY EXAMINATION Dear Customer, Thank you for choosing a HANNA instruments product.
More informationType K/J Thermometers
Type K/J Thermometers 800005 CONTENTS INTRODUCTION....2 FRONT PANEL DESCRIPTION...3 LCD DISPLAY....4 OPERATION INSTRUCTION...5 Power Up....5 Connecting the Thermocouples....5 Selecting Temperature Scale....5
More informationTEMPERATURE
S E C T I O N 11 C O N T E N T S N A V I G A T I O N Introduction....................11.2 K-Type Thermocouple Thermometers..................11.7 K, J, T-Type Thermocouple Thermometers................11.15
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850070 Mini Environmental Quality Meter 850070 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More information4-Channel Thermometer
4-Channel Thermometer 800023 4-Channel Thermometer - 800023 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in
More informationINSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs
INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,
More informationHI 2300 Auto-ranging Microprocessor EC/TDS/NaCl/ºC Bench Meter
/ LOCK C Instruction Manual HI 2300 Auto-ranging Microprocessor EC/TDS/NaCl/ºC Bench Meter T Functions Select Measurement RANGE Range ALT GLP ATC TC SETUP Start Calibration LOCK Lock Current Range Change
More informationManual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER
Manual No. 9835 Revision 0-401 MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER Please read this instruction manual carefully before using the instrument. This manual will provide you with all
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More information4-Channel Datalogging Thermometer
4-Channel Datalogging Thermometer 800024 4-Channel Datalogging Thermometer - 800024 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced
More informationUser s Guide. 600A AC Clamp Meter. Model 38387
User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationTC100 Precision Thermocouple Calibrator
TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6
More informationDatalogging Conductivity/ TDS Meter. Instruction Manual
Datalogging Conductivity/ TDS Meter 850039 Instruction Manual 1 TABLE OF CONTENTS 1. INTRODUCTION...3 2. PANEL DESCRIPTION...4 3. MEASURING PROCEDURE...5 3-A General Measurement...5 3-B Auto and Manual
More informationOperation Manual. Hand-held ph/mv/temperature Meter. ph6810
Operation Manual Hand-held ph/mv/temperature Meter ph6810 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4
More informationUSER GUIDE. Differential Thermometer Datalogger. Model HD200
USER GUIDE Differential Thermometer Datalogger Model HD200 Introduction Congratulations on your purchase of the Extech HD200 Differential Thermometer Datalogger. The HD200 supports differential temperature
More informationUser's Guide. Model Laser Photo Tachometer
User's Guide Model 461920 Laser Photo Tachometer Introduction Congratulations on your purchase of Extech's Mini Laser Photo Tachometer, Model 461920. This Tachometer provides non-contact RPM and Revolution
More informationPT2000-PT2100 User Manual
1450 First Ave. Page 1 of 5 PT2000 & PT2100 User Manual 1450 First Ave. Page 2 of 5 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after
More informationUser Manual. Thermocouple Datalogging Thermometer. Model EA15
User Manual Thermocouple Datalogging Thermometer Seven (7) Thermocouple input types K, J, T, E, R, S, N Dual thermocouple Input with PC Interface Model EA15 Additional User Manual Translations available
More informationModel R2400. Instruction Manual. Digital Thermocouple Thermometer. reedinstruments
Model R2400 Digital Thermocouple Thermometer Instruction Manual reedinstruments com 1-877-849-2127 info@reedinstruments.com.reedinstruments.com Table of Contents Safety... 2 Features... 3 Specifications...3-4
More informationUser's Manual. Model Heavy Duty Datalogging Module with Windows Software
User's Manual Model 380340 Heavy Duty Datalogging Module with Windows Software Stores data for later recall and analysis Can be used with any Extech Heavy Duty meter Selectable recording interval Battery
More informationInstruction Manual Temp JKT Temperature Meter Series
Instruction Manual Temp JKT Temperature Meter Series 68X243615 Technology Made Easy... Rev. 2 11/03 Preface This manual serves to explain the use of the Temp JKT temperature meter. This manual functions
More informationAnemometer/Thermometer
Anemometer/Thermometer 840003 840003 Anemometer/ Thermometer measures both air speed and temperature in a light weight, compact unit. Measures air velocity in 5 scales: m/s, km/hr, mile/ hr, knots, or
More informationHI HI HI HI HI HI 98185
Instruction Manual HI 98180 HI 98181 HI 98182 HI 98183 HI 98184 HI 98185 Calibration Check Waterproof ph/mv/ise/temperature Meters www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments
More informationWalkLAB ph mv/orptemperature
16,1,16,1,2,15,2,15,14,3,14,3,4,13,4,13,12,5,12,5,6,11,6,11,10,7,10,7,8,9,8,9 WalkLAB ph mv/orptemperature meter HP9000 Operations Manual TABLE OF CONTENTS PAGE 1. INTRODUCTION 1 1.1 Features 1 1.2 Technical
More informationph 300 ph 301 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ C Meters Instruction Manual
Instruction Manual ph 300 ph 30 ph 302 Microprocessor GLP Bench-top ph/mv/ise/ Meters Rel mv ppm ph DATE TIME MEM mv ppm ph INTV WRONG m BUF 2 s LOG 3 ON OFF PAPER PRINT ph302 ph METER RANGE / TIME PGM
More informationINSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage
INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero
More informationHeavy Duty Mini Vane CFM Thermo Anemometer
User's Manual Heavy Duty Mini Vane CFM Thermo Anemometer Model 407117 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three years from
More informationPIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics
PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850025 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com Mini Environmental Quality Meter 850025 Copyright
More informationModel ST-610B. Instruction Manual. Digital Thermocouple Thermometer. reedinstruments. www. com
Model ST-610B Digital Thermocouple Thermometer Instruction Manual reedinstruments com Table of Contents Safety... 2 Features... 3 Specifications...3-4 Operating Instructions... 5 Additional Functions...
More informationMini Environmental Quality Meter
Mini Environmental Quality Meter 850025 Mini Environmental Quality Meter 850025 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced
More informationOperation Manual. Hand-held ph/orp/temperature Meter 6010M
Operation Manual Hand-held ph/orp/temperature Meter 6010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......3 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4
More information1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.
CONTENTS TITLE PAGE 1. Introduction.. 1 2. Specifications... 1 3. Symbol Definition and Button Location... 2 4. Operation Instructions.... 3 4.1 Power-Up...3 4.2 Connection of the Temperature Probe...
More informationInstruction Manual HI Autoranging & Logging Portable Waterproof Microprocessor EC/TDS/NaCl/ C Meter
Instruction Manual HI 98360 Autoranging & Logging Portable Waterproof Microprocessor EC/TDS/NaCl/ C Meter www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments product. Please read
More informationAdvanced Datalogging Thermometer. Instruction Manual
Advanced Datalogging Thermometer 800008 Instruction Manual Advanced Datalogging Thermometer - 800008 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity
More informationInstruction Manual HI HI Portable Microprocessor Printing and Logging Multi-Range Conductivity Meters
Instruction Manual HI 933300 HI 933301 Portable Microprocessor Printing and Logging Multi-Range Conductivity Meters These Instruments are in Compliance with the CE Directives http://www.hannainst.com Dear
More informationUser Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP
0 User Guide ExStik TM Model RE300 Waterproof ORP Meter Patent Pending 500 MV 1000 TM RE300 ORP ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE button 4. CAL
More informationOperations Manual EcoSense ph100
Operations Manual EcoSense ph100 Portable ph, mv and Temperature Instrument English Français Español Deutsch Italiano WARRANTY The EcoSense ph100 Instrument is warranted for one year from date of purchase
More informationAPO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2
User s Guide Dual Input, 3-Display Thermometer/Datalogger Model 421509 Accepts J, K, T, E, R, S, & N thermocouples Internal Memory stores up to 16 data sets, with 1024 maximum data capacity Backlit Electro-luminescent
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationRH/Temperature SD Card Datalogger. Instruction Manual
RH/Temperature SD Card Datalogger 800021 Instruction Manual RH/Temperature SD Card Datalogger 800021 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual
More informationUser's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented
User's Guide 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your
More informationDual Input, 3-Display Thermometer/Datalogger Model
USER GUIDE Dual Input, 3-Display Thermometer/Datalogger Model 421509 Accepts J, K, T, E, R, S, & N thermocouples Internal Memory stores up to 16 data sets, with 1024 maximum data capacity Backlit Electro-luminescent
More informationOperation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller
Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3
More informationUser's Guide. Heavy Duty Vane Thermo-Anemometer. Model
User's Guide Heavy Duty Vane Thermo-Anemometer Model 407112 407112 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date
More informationCL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual
SIMPLE LOGGER RMS CLAMP-ON MODULE CL600 E N G L I S H User Manual Owner s Record The serial number for the Simple Logger Model CL600 is located on the back of the instrument. Please record this number
More informationSoilStik ph Meter PRODUCT MANUAL
SoilStik ph Meter PRODUCT MANUAL Item # 2105 2 Contents General Overview...3 LCD Display...4 LCD Display Messages...5 Meter Components...6 Calibration...7 Changing the Temperature Units...8 Taking Liquid/Soil
More informationUSER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at
USER MANUAL Heavy Duty Manifold Pressure Gauge Model HD780 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech Instruments Heavy
More informationHANDHELD CALIBRATOR-MULTIMETER OC502-t
OC502-t_GBM_21311 HANDHELD CALIBRATOR-MULTIMETER OC502-t Owner s Manual ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch
More informationRS Stock No Instruction Manual RS Input Data Logging Thermometer
RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2
More informationPIECAL 520B & 521B Thermocouple Source Operating Instructions
PIECAL 520B & 521B Thermocouple Source Operating Instructions (Shown without optional boot) Product Description (Shown with optional boot) Easy to use With the PIECAL 520B/521B you can check & calibrate
More informationVacuum Meter Instruction Manual
Vacuum Meter 840064 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...2 2. METER DESCRIPTION...3 3. OPERATING INSTRUCTIONS 3-A PRECAUTIONS - READ BEFORE FIRST USE...4 3-B MEASUREMENT PROCEDURE...4
More informationMC1000 Multi-Function Calibrator
MC1000 Multi-Function Calibrator Table of Contents 1. Introduction 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2 2. Quick Start Instructions
More informationAnemometer SD Card Datalogger. Instruction Manual
Anemometer SD Card Datalogger 850023 Instruction Manual 1 Anemometer SD Card Datalogger 850023 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not
More informationOperation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller
Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3
More informationL610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual
SIMPLE LOGGER THERMOCOUPLE MODULE L610 L620 L630 E N G L I S H User Manual Owner s Record The serial number for the Models L610, L620 and L630 is located on the side of the case. Please record this number
More informationPlatinum RTD Thermometer MODEL NO
Platinum RTD Thermometer MODEL NO. 93410-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com
More informationOperation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter
Operation Manual MODEL ph6175 Microcomputer Based ph/orp/temperature Benchtop Meter ph6175 0 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 POWER INPUT.......2 INSTALLING THE BATTERIES.....3
More informationInstruction Manual C 102. Multiparameter Turbidity & Ion Specific Meter. This Instrument is in Compliance with the CE Directives.
Instruction Manual C 102 Multiparameter Turbidity & Ion Specific Meter This Instrument is in Compliance with the CE Directives www.hannainst.com Dear Customer, Thank you for choosing a Hanna Product. Please
More informationUSER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements
USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting
More informationInstruction Manual HI Portable Logging Haze Meter
Instruction Manual HI 93124 Portable Logging Haze Meter w w w. h a n n a i n s t. c o m 1 Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using
More informationDatalogging Hot Wire CFM Anemometer
Datalogging Hot Wire CFM Anemometer 840002 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS 1. INTRODUCTION... 3 2. PANEL DESCRIPTION... 4-5 3. MEASURING PROCEDURE... 5 3-A Air Velocity and Ambient
More informationOwner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español
Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationHI HI 8314 HI HI 8915 HI HI HI 9622 Portable ph Meters
HANNA LITERATURE Hanna publishes a wide range of catalogs and handbooks for an equally wide range of applications. The reference literature currently covers areas such as: Water Treatment Process Swimming
More informationHeavy Duty Psychrometer + IR Thermometer Model HD500
User Guide Heavy Duty Psychrometer + IR Thermometer Model HD500 Introduction Congratulations on your purchase of the Extech HD500 Psychrometer. This handheld meter measures and displays Air Temperature,
More informationLight Meter with Bar Graph
Light Meter with Bar Graph 840020 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 MEASUREMENT PROCEDURES... 3-4 ZERO ADJUSTMENT... 4 BATTERY REPLACEMENT...
More informationDigital Vane Thermo-Anemometer Model
User's Guide Digital Vane Thermo-Anemometer Model 451104 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment
More informationTrue RMS AC Voltage/Current Datalogger
User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long
More informationThermocouple Thermometers
Thermocouple s, Datalogger, Printer Extech offers a selection of thermometers with datalogging and printing capabilities for data storage analysis and report generation. Featuring Model HD200 Dual Input
More informationVisible Light SD Card Datalogger
Visible Light SD Card Datalogger 850007 Instruction Manual Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand Tel: 66-3844-6117 sale@ete.co.th www.eastern-energy.com Visible
More informationOxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA
Oxygen Pen 800047 Oxygen Pen - 800047 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means
More informationOperations Manual EcoSense ph100a
Operations Manual EcoSense ph100a Portable ph, mv and Temperature Instrument English CONTENTS GENERAL INTRODUCTION... 3 INITIAL INSPECTION... 3 THE INSTRUMENT... 3 BATTERY INSTALLATION... 3 Battery Disposal...
More informationLaser Photo/ Contact Tachometer. m/min. ft/min
User's Manual Model 461995 Laser Photo / Contact Tachometer Laser Photo/ Contact Tachometer 461995 MEMORY rpm PHOTO CONTACT ft/min m/min Introduction Congratulations on your purchase of Extech's Laser
More informationPlatinum RTD Thermometer MODEL NO
Platinum RTD Thermometer MODEL NO. 93410-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationCA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free
THERMO-HYGROMETER CA846 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com ENGLISH User Manual Statement of Compliance Chauvin Arnoux,
More informationModel A Current / Voltage Calibrator. User's Guide
Model 412355A Current / Voltage Calibrator User's Guide Introduction Congratulations on your purchase of the Extech Current/Voltage Calibrator. The Model 412355A can measure and source current and voltage.
More informationAquaShock ph Meter K
AquaShock ph Meter 850057K 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com AquaShock ph Meter 850057K Copyright 2011 by Sper Scientific
More informationINSIDE-OUTSIDE THERMOMETER WITH MIN/MAX MEMORY USER S MANUAL
INSIDE-OUTSIDE THERMOMETER WITH MIN/MAX MEMORY USER S MANUAL DTR900 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction...................... 3 4
More informationOperation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M
Operation Manual Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS
More informationSound Level Pen Instruction Manual
Sound Level Pen 840018 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...................2 2. DESCRIPTION.................... 3 3. OPERATING INSTRUCTIONS........... 4 PRECAUTIONS AND MAINTENANCE.......4
More informationLight Meter (Foot Candles)
Light Meter (Foot Candles) 821 Light Meter (Foot Candles) - 821 Copyright 215 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
More informationHI HI 9034 HI HI 9130 HI HI 9635 Portable Waterproof Multi-Range Conductivity/TDS/ Fertilizer Meters
CONDUCTIVITY CFM BUF Instruction Manual HI 9033 - HI 9034 HI 9039 - HI 9130 HI 933100 - HI 9635 Portable Waterproof Multi-Range Conductivity/TDS/ Fertilizer Meters ins rum n s ms HI 933100 MICROPROCESSOR
More informationWide Range Pressure Meter Instruction Manual
Wide Pressure Meter 840065 Instruction Manual Wide Pressure Meter - 840065 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or
More informationUser's Guide. Hot Wire Thermo-Anemometer Model Introduction
User's Guide Hot Wire Thermo-Anemometer Model 407123 Introduction Congratulations on your purchase of the Extech Hot Wire Anemometer. This meter measures air flow and temperature by placing the sensor
More informationUser Guide. ExStik FL700. Fluoride Meter
User Guide ExStik FL700 Fluoride Meter Introduction The model FL700 is a system specifically designed for the quick and accurate measurement of fluoride ions in drinking water and other aqueous samples.
More informationUser's Guide. EasyView K-Type Thermometer. Model EA11A
User's Guide EasyView K-Type Thermometer Model EA11A Introduction Congratulations on your purchase of the Extech EasyView Thermometer. This device offers a single K-type thermocouple input with multifunction
More informationThermocouple Calibrator
USER GUIDE 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Thermocouple Calibrator Model PRC20 Introduction Thank you for selecting
More informationP OCKET POWER 9000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT
P OCKET POWER 9000 T M Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT HALO POCKET POWER 9000 Thank you for choosing HALO. Innovative, fashionable and easy to use, the HALO
More informationTorque Meter. Instruction Manual
Torque Meter 840062 Instruction Manual CONTENTS I. Introduction... 4 II. Meter Description... 4 III. Operating Instructions 1. Measuring Procedures... 5 2. Automatic Shut Off... 6 3. Battery Replacement...
More information