Cemar Electro Inc. MAXX-1100Laser Positioning System. Installation and Set-up Manual

Size: px
Start display at page:

Download "Cemar Electro Inc. MAXX-1100Laser Positioning System. Installation and Set-up Manual"

Transcription

1 Cemar Electro Inc. MAXX-1100Laser Positioning System Installation and Set-up Manual Cemar Electro Inc th Avenue Lachine, QC H8T 3J8 Canada Phone: Fax: Toll free:

2 WARNING This manual contains the latest information at the time of publication. Cemar Electro Inc. reserves the right to revise this manual without notice. The MAXX-1100 Moving Laser Patient Positioning System is intended for use only by physicians qualified in diagnostic radiology and radiation therapy and experienced in marking patients utilizing patient positioning lasers or by therapists at the specific direction of such a qualified physician. It is the sole responsibility of the physician to judge whether the use of the MAXX-1100 Moving Laser Patient Positioning System is clinically appropriate. Page 2

3 TABLE OF CONTENTS Section 1: Introduction - Pg.7 Section 2: System Overview - Pg.8 Section 3: Laser Safety Considerations for MAXX-1100 Units - Pg General Safety 3.2 Safety and Functionality, and Maintenance 3.3 Safety Labels Required for MAXX-1100 Units 3.4 Technical Specifications 3.5 Protective Eyewear 3.6 Storage Section 4: System Components Pg MAXX-1100 Unit Laser Line Adjustment Tilt Adjustment Rotation Adjustment 4.2 System Controller Controller Connections Section 5: Treatment Room Preparation Pg General Room Layout 5.2 Mounting Base Plates 5.3 Maxx-1100 Mounting Options Ceiling Mount Wall Mount Floor Mount 5.4 Cable Routing 5.5 Power Requirements Section 6: Laser Installation Pg Establishing IsoCentre Reference Marks 6.2 Finding the Treatment Room Radiographic Centre 6.3 Using the Rotating Laser 6.4 Installing Lasers Page 3

4 6.4.1 Floor Mounting Wall Mounting Ceiling Mounting Section 7: System Connection Pg Maxx-1100 Unit Power-up 7.2 System Cable Connections 7.3 System Controller Power-up Section 8: System Alignment Pg Basic Laser Alignment Concepts Laser Origin Point must be in the Correct Plane Tilt the Laser Plane to the Correct Alignment Y Plane X Plane Z Plane Rotate the Laser Plane to the Correct Alignment Y Plane X Plane Z Plane 8.2 Specific Laser Alignment Procedures Locating the LOP for all Maxx-1100 System Lasers in the Correct Plane Lop Location of Maxx-1100 Using the Rotating Laser Z Plane Y Plane Aligning Lasers in the Y Plane Align the Fixed Laser Aligning Lasers in the Z Plane Align the Moving Lasers Aligning the Laser in the X Plane Final Alignment Verification Section 9: Remote Control User Guide Pg Powering Up the System Charging Remote Control Powering Up Remote Control Page 4

5 9.1.3 Laser Unit Displays 9.2 Remote Control Operation Pan ID Box Laser Operations Icon Remote Control Settings Icon General Use of Remote Control 9.3 Linking and Status Checking Wireless Communication Status Laser Status Indicators Check Status Icon 9.4 Laser Unit Status Laser Status Indicators Laser Operations Icons 9.5 Home/CT Zero Operations Current Zero Box Unit-Axis Selection Current Laser Position Laser Moving Icons CT Zero Function Icons Set CT Zero Point Homing Lasers to CT Zero Changing Zero Settings Zero Settings Icons Switching from CT Zero to Patient Zero Switching from CT Zero/Patient Zero to Reset Zero Switching from Patient Zero/Reset Zero to CT Zero 9.6 Laser Configuration/Adjustment Navigation Icons Unit Selection Icons Power Level Grid Power Function Icons Laser Speed Adjustment Speed Bar Speed Function Icons 9.7 Laser Line Positioning Navigation Icons Page 5

6 9.7.2 Axis Selection Icon Current Laser Position User Input Icons Laser Positioning 9.8 Express Points Operations Navigation Icons Express Points Function Icons Unit Number Icons Position Fields Express Points Main Operations 9.9 Remote Control Settings Revision Number Box Battery Capacity Indication Local Function Icons Low Battery Warning Power Saving Settings LCD-off Timer Setting Sleep Timer Setting Save Changes Icon Wake-up Methods 9.10Network ID Configuration Password Input Other Icons 9.11 Troubleshooting Appendix A: Warranty Pg-72 Page 6

7 SECTION 1: INTRODUCTION This Installation and User s Guide includes all the information you need to safely and efficiently install, operate and maintain your MAXX-1100 Laser Alignment System. The Treatment Room Moving Laser Patient Positioning System consists of one to three MAXX-1100 units; the Maxx-1100 Unit(s) is connected to a central system controller. Operators interface with the controller using a remote control. The controller can also be configured for a network interface to the treatment planning system. The purpose of this manual is to provide instructions on the installation and setup of the moving lasers within the treatment room. This manual also includes basic operating instructions for the MAXX-1100 Unit, its Controller, and its computer software system. This Installation and Set-up Manual pertains to Revision 1.1.4, of the MAXX-1100 Unit. Please make sure that your remote control and all the documents have the same revision number. Page 7

8 SECTION 2: SYSTEM OVERVIEW The MAXX-1100 laser system consists of several moveable crosshair lasers, a handheld remote control, and a PC controller, operated by a comprehensive software system. The lasers within the MAXX-1100 define the planes of the treatment room. Within an appropriately established treatment room, the MAXX-1100 permits the successful preparation and treatment of patients via radiation therapy. The lasers are adjusted to the offset point of the treatment room. Offset points allow medical personnel easy access to the patient for marking purposes. This system allows medical personnel and system operators to directly identify tumour locations and mark patients for treatment. Note: Use of the MAXX-1100 laser system other than its intended use is carried out entirely at the user's risk. Page 8

9 SECTION 3: LASER SAFETY CONSIDERATIONS 3.1 GENERAL SAFETY To help ensure safe operation of your MAXX-1100 system, please read this section carefully and follow the instructions and procedures in this manual before installing and operating the units. At all times during installation, operation, or adjustment of a MAXX-1100 unit avoid staring into the beams or other sources of bright light emanating from the unit. The MAXX-1100 is a class ll 1mW laser. The American National Standards Institute (ANSI) notes that Class 2 lasers are CW and repetitively pulsed lasers with wavelengths between 0.4 µm and 0.7 µm that can emit energy in excess of the Class 1 AEL, but do not exceed the Class 1 AEL for an emission duration less than 0.25 seconds and have an average radiant power of 1mW or less. Should adjustment or alignment be necessary at any time once the laser is activated the patient s eyes should be protected. 3.2 SAFETY, FUNCTIONALITY, and MAINTENANCE For accuracy integrity, Isocentre of diagnostic and treatment equipment must match the Isocentre of alignment lasers. All positioning equipment in the treatment room should be measured at least twice: once upon initial installation and once before service to ensure that construction materials in the walls, floor, and ceiling have settled into position. Realign lasers to Isocentre before use, if they have moved. Testing the alignment of lasers to Isocentre of diagnostic or treatment equipment is based on hospital procedures. The MAXX-1100 is a class ll 1mW laser. Replace laser diode only with assembly provided by Cemar Electro Inc. to ensure that laser power levels do not exceed class ll 1mW limits. The Maxx-1100 unit is virtually maintenance free requiring only visual inspection and cleaning of the encoder glass annually (with a dry lint free cloth) the exterior can be cleaned with a damp cloth. Page 9

10 3.3SAFETY LABELS FOR MAXX-1100 UNITS The labels on all MAXX-1100 units are required for compliance with federal regulations. Do not remove these labels. Safety labels are located on the laser unit: Figure 3.1 Safety label. Figure 3.2 Class II laser product label. (North America and EU) Page 10

11 3.4TECHNICAL SPECIFICATIONS Specifications for MAXX-1100 used in treatment rooms are as follows: Technical Specifications for Treatment Room Category Feature Specification Laser control Number of axes 4 Electrical Remote X axis: Horizontal movement Y axis: Vertical movement Z-axis: X axis line Roll axis: Horizontal rotation Micro-step Course Accuracy Power supply Fuse (line) Fuse (internal) Charging Base MAXX-1100RC Remote Battery (Not serviceable return to Cemar Electro for service or disposal) *Do not attempt to change battery. Do not attempt to charge nonrechargeable Batteries. 600mm total travel +/- 25mm 600mm from encoder zero 1mm=25 steps; degrees 0.2 mm Continuous movement 0.1 mm V AC, 2.0A, 47-63Hz, 120W 2.0A Auto Recovery fuse Input: V AC, 50-60Hz, 0.8A(Output 5Vdc.8A) Rated Capacity Min. 2300mAh Nominal Voltage 3.7V Charging CC CV, Std. <2.4A, 4.20V, 3.0 hrs. Weight 48.0g Temperature Charge: 0 to +45 Deg. C Discharge: 20 to +60 Deg. C Storage: <35 Deg. C Mechanical Laser unit dimensions Length: mm (57.7 in) Weight Width: mm (7.79in) Height: mm ( in) 34.0 kg (74.95lbs.) Environmental Operating temperature 5 C - 35 C (40-95 F) Operating humidity Others Cleaning Instructions 0% - 85 % relative humidity Ensure no dew or condensation IP20No flammable anaesthetics No corrosives, (no ammonia); use a soft lint free cloth to wipe down encoder annually or when errors occur and a moist cloth for the unit. Page 11

12 3.5 PROTECTIVE EYEWEAR Protective eyewear is not necessary for typical applications where direct papillary impingement by the beams is a random momentary event. Under typical conditions requiring more protracted ocular exposure, protective eyewear or other protective measures may be required. Consult the user standards of the ANSI for further guidance ( 3.6STORAGE To ensure optimal functionality of the MAXX-1100 unit, ensure the following: Do not drop Store all components in a non-corrosive environment Maintain storage temperature between -20 C and +75 C (-4 F and167 F) Maintain storage humidity between 20% and 85% relative humidity. Do not permit dew condensation Page 12

13 SECTION 4: SYSTEM COMPONENTS The overview of the system configuration for the MAXX-1100 is shown in Figure 4.1. The configuration table should be completed at the time of purchase. Before beginning installation of the laser system, verify that all components shown on the system configuration chart have been provided. If any required system components are missing, please contact Cemar Electro Inc. immediately for assistance. A description of the major system components in a moving laser patient positioning system is given in the following paragraphs. Figure 4.1 shows the typical system components. Figure 4.1 System Components 4.1 MAXX-1100 Unit Each Maxx-1100 unit can generate three orthogonal laser lines, one perpendicular to the long axis of the Maxx-1100 unit frame, and two parallel to the long axis of the Maxx-1100 unit frame Page 13

14 Moving laser: The line perpendicular to the long axis of the Maxx-1100 unit frame is generated by a diode that can be moved along the long axis of the actuator. It has a linear movement of +/-300mm from the laser travel zero. (Figure 4.2) Fixed laser(s): (Optional) The line(s) parallel to the long axis of the Maxx-1100 unit frame is generated by a laser diode that is fixed in position at one (or both ends) end of the actuator. Also has a manual linear adjustment of +/-10mm from the centre point. (Figure 4.2) Each Maxx-1100 unit has an identity in the system, and can be used as a single unit system, a two unit system, or a complete three unit system. (Figure 4.1) Z Actuator: The Z actuators are located on either side of the treatment couch, and are referred to Maxx-1100 unit 1 or Maxx-1100 unit 2. X Actuator: The X actuator is mounted directly over the isocenter point, and is referred to Maxx-1100 unit LASER LINE ADJUSTMENT Proper alignment of the laser lines requires precise adjustment of the laser lines within the confines of the treatment room. Two adjustments are possible for each laser diode, namely, tilt adjustment and rotation adjustment. (Figure 4.2) TILT ADJUSTMENT Tilt adjustment allows the laser line to pivot from end to end for the moving laser, adjusting the positioning relative to the moving axis of the Maxx-1100 unit, and side to side for the fixed laser relative to the moving axis of the Maxx-1100 unit. (Figure 4.2) ROTATION ADJUSTMENT For the moving laser the rotation adjustment alters the angle of the laser line to be parallel to the moving axis of the Maxx-1100 unit by rotating the laser diode. The rotation adjustment alters the fixed laser line angle so that it is perpendicular to the moving laser. (Figure 4.2) 4.2 SYSTEM CONTROLLER PC. (Optional) The system controller (PC) can control multiple-axis configurations, allowing the movement of up to three Maxx-1100 units. All controllers include a Monitor, a router, and all necessary cabling. (Figure 7.1) Page 14

15 4.2.1 CONTROLLER CONNECTIONS The system controller has a multiple output router; this is used to communicate with each Maxx-1100 unit which are connected to the router with a Cat6 cable. (Figure 7.1) Figure 4.2 Lasers Layout and Adjustments SECTION 5: TREATMENT ROOM PREPARATION Correct treatment room set-up is crucial to the successful installation of a patient positioning system. Preparation work on the treatment room should be completed before the system components are shipped to the installation site. Necessary preparation work comprises: Establishing where various system components will be located within the room Determining the mounting configuration for each laser unit Providing an adequate structure to mount all the laser units in the system Page 15

16 Determining routings for cables Establishing necessary power for the system In the case where the treatment room is not yet constructed, Cemar Electro Inc. recommends that a rigid steel support frame for the Maxx-1100 units is incorporated into the room construction. (Figure 5.1) Figure 5.1 Typical Room Layout and Ceiling Mounting Figure 5.1 Typical Room Layouts and Ceiling Mounting Page 16

17 5.1 GENERAL ROOM LAYOUT The treatment room must meet the following specifications to permit for installation of the MAXX-1100 unit. Treatment Room Specifications Category Feature Specification Electrical Power supply V AC, 3A, 50-60Hz Mechanical Environmental Laser unit dimensions Wall/Ceiling Mount Floor Mount Weight Room size Operating temperature Operating humidity Length: mm (57.7in) Width: mm (7.79 in) Height: mm (9.44 in) Incl. mount. Length:250 Width:260 Height: kg (64 lbs) 3M(9.84ft) x 5M(16.4ft) x 2.3M(7.84ft) 5 C - 35 C (40-95 F) 10% - 85 % relative humidity Ensure no dew or condensation Others No flammable anaesthetics No corrosives Room layout begins by identifying the location of the point in the room that will be the isocenter for the patient positioning system. (Figure 5.1) Note: The radiographic centre point of the room is not the same as the isocenter of the laser positioning system. Both the radiographic centre and the isocenter typically have the same X and Z coordinate, their Y coordinates differ. In this manual, the isocenter will always be referred to as such. Page 17

18 Figure 5.2 Isocentre position. Once the isocenter location has been determined, the installation location of the system lasers can be determined. (Figure 5.2) The X actuator (Maxx-1100 Unit #3) should ideally be mounted directly over the isocenter point, using a ceiling mount configuration with the Laser Travel Zero near to the centre of the treatment couch. This permits the X line to be viewed at consistent intensities, and full laser travel on treatment couch. The Z actuators (Maxx-1100 Unit #1 and Unit #2) should be located on either side of the treatment couch, aligned perpendicularly to the long side of the treatment couch, with the Laser Travel Zero near to the isocenter. 5.2 MOUNTING BASE PLATES Steel or aluminum base plates (Hospital Contractor supplied and installed) can be located in the walls and ceiling where the laser units are to be mounted or a reasonable alternative like U-Channel. The location, size, and stability of these base plates or Channels are critical to a satisfactory installation of a moving laser system. (Figure 5.1) Page 18

19 ** This rigid structure is required because any movement of the mounting structure for the Maxx-1100 unit will result in movement of the laser lines. 5.3 Maxx-1100 MOUNTING OPTIONS Two mounting options are available for the X actuator (Unit #3) in the system. (Figure 4.1) Option 1. The preferred option is a ceiling mount directly over the treatment couch. This allows the optional fixed laser(s) in the X actuator (Unit #3) to be aligned as part of the Y plane in the system. This permits the X line to extend unobstructed over the full length of the patient s body. Option 2. A second option for the X actuator (Unit #3) is a Gantry system. In this case, the X actuator (Unit #3) is mounted to the tops of the Z actuators (Unit #1 and Unit#2), but the lasers are positioned closer to the treatment couch. There are three mounting options available for the Z actuators (Unit #1 and Unit#2) in the system. (Figure 4.1) Option 1. If the walls of the treatment room are within 3 meters of the treatment couch, the actuators can be mounted directly to the walls. Option 2. A second option for the Z actuators (Unit #1 and Unit#2) is a Gantry system. In this case, the Z actuators are mounted under the X actuator (Unit#3), but the lasers are positioned closer to the treatment couch. Option 3. If the treatment couch is located far from the walls of the treatment room, a floor mount could be used for the Z actuators (Unit #1 and Unit#2). The laser lines are pre-focused to a distance of 2 to 3 meters from the actuator. If the Z actuators must be mounted at an angle relative to the wall, or at a distance closer to the treatment Couch re-focusing may be necessary. Finally, consider mounting the Z actuators (Unit #1 and Unit#2) on or as close to the walls as possible; this avoids possible interference with treatment room personnel CEILING MOUNT The ceiling mount arrangement is shown in Figure 4.1. The ceiling must feature a rigid structure (Hospital Contractor supplied and installed) within its construction. Typically, this rigid structure is a metal plate built into or affixed on the ceiling or a channel mounting system. It is to this installation that the pivot-bracket mountings (Supplied with Maxx-1100 Unit) will be connected. Page 19

20 5.3.2 WALL MOUNT As with the ceiling, the walls must feature a rigid structure (Hospital Contractor supplied and installed) within their construction. Typically, this rigid structure is a metal plate built into or affixed to the wall or a channel mounting system to which the pivot-bracket mountings (Supplied with Maxx-1100 Unit) will be attached. The wall mount arrangement is shown in Figure 4.1. For a wall mounting, a rigid structure is affixed to each wall FLOOR MOUNT A Maxx-1100 unit can be secured to the floor in a vertical configuration using a floor mount pedestal (Supplied with Maxx-1100 Unit). The floor mount arrangement is shown (Figure 5.1) Floor mounting allows lasers to be mounted vertically, but attached to the floor. This configuration is advantageous in allowing the user to easily orient the Z actuator (Unit #1 or Unit #2) at any distance with respect to the treatment couch. This is particularly convenient in treatment rooms where the couch is installed at a long distance from the walls of the room. 5.4 CABLE ROUTING (For the Optional controller) Maxx-1100 unit in the system must be connected to the computer controller by an Ethernet cable. Cables are provided at specified lengths. Provisions should be made in the treatment room to route these cables as directly as possible to the system controller while not posing any hazard to personnel working in the room. (Figure 5.1) Maxx-1100 unit cables may also be routed through conduit. If this is done, the conduit should be of a minimum inside diameter and any bends should be a large and gradual enough to allow the cable connectors to be pulled through the conduit without undue stress. 5.5 POWER REQUIREMENTS For the MAXX-1100 System, a separate power outlet is required for each Maxx-1100 unit. Each Maxx-1100 unit requires VAC 1A, 50-60Hz. The Maxx-1100 unit is equipped with a power on/off switch, but if the treatment room configuration allows, it may be desirable to install a single switch to control outlets to the units. (Figure 5.1) If the optional system controller is used, one power outlet is required for the system controller PC. The system controller PC requires V AC 8/4A, 50-60Hz power Detachable mains supply cords are provided, use of other detachable mains supply cord must meet adequate ratings, (see technical Specification table). Page 20

21 SECTION 6: LASER INSTALLATION Before the Maxx-1100 units can be correctly installed in the treatment room, the system isocenter must first be identified. Once identified, templates (Supplied with Maxx-1100 Unit) should be placed on the wall to determine the precise location of the mounting. In the following sections on laser installation, it is assumed that a mounting base plate or alternately a Channel system (Hospital Contractor supplied and installed) has already been installed in the correct location to mount the lasers. 6.1 ESTABLISHING ISOCENTRE REFERENCE MARKS The primary task in patient positioning system installation is establishing reference marks for each of the three planes for the lasers. (Figure 6.1) Ideally, the X actuator and Z actuator coordinates of the laser system centre will correspond with the radiographic zero of the treatment room. Y-axis of the laser system is typically offset some distance from the centre of the radiographic scan plane (i.e., 600 mm). This offset value should be noted for future use in patient setup. (Figure 5.2) 6.2 FINDING THE TREATMENT ROOM RADIOGRAPHIC CENTRE Three options are possible for determining the treatment room radiographic centre; options are listed in order of accuracy: 1. Using a scan to find the radiographic centre 2. Using treatment equipment s internal lasers to find the radiographic centre 3. Using physical measurement to find the radiographic centre Figure 6.1 Phantom overview Page 21

22 6.3 USING THE ROTATING LASER A rotating laser can be used to establish the Y, Z, and X planes for the Maxx-1100 system based on the scan of the installation phantom. (Figure 4.1) and (Figure 6.1) Note: When moving the phantom side to side, be careful not to change the angle of the phantom, or else the steps to align the phantom with the scan plan will need to be repeated. While performing the above scan procedures, the grooves on the sides of the phantom may not line up with the grid on the scan image (i.e., the image of the phantom is rotated relative to the grid). If this occurs, verify that the phantom is level and adjust and re-scan as necessary. The patient positioning lasers should be installed in a coplanar orientation with no Parallax. If the image in the CT simulator is not oriented correctly with respect to the horizontal plane, it will be difficult or impossible to correctly mark and position the patient for treatment. 6.4 INSTALLING LASERS FLOOR MOUNTING A floor mount requires four studs to be installed in the floor, a floor template (Supplied with Maxx-1100 Unit) is used; wall/ceiling mounting template cannot be used. In order for the laser centre to be located in the Y reference plane, the Floor Mount Pedestal for the Maxx unit must be mounted in the correct location. (Figure 4.1) The holes in the base plate of the pedestal are elongated to allow for some adjustment of both angle and the lateral position. Step 1. Position the floor template so that the reference line for the centre of the laser corresponds with the line determined by the marks made on the floor to define the Maxx-1100 unit s Y reference plane. Step 2. Mark, drill and install mounting studs. Step 3. Place and loosely secure the Floor Mount Pedestal. Step 4. Remove front covers for the Floor Mount Pedestal and Maxx-1100 unit. Step 5. Position and mount the Maxx-1100 unit to the top of the Floor Mount Pedestal, and secure them together using the provided 8mm bolts. Step 6. Align to the Y plane of the room; shim under the base plate as required so all plate holes are in contact with the floor. Step 7. Tighten in this position. Repeat for other unit. Step 8. To verify that the Laser Travel Zero of the two Maxx-1100 units is aligned, use any line-generating device to project a line on the Laser Travel Zero indicator stickers. This projected line should intersect the reference stickers, if not shims may be required if the different is more than 5mm. Step 9. The Maxx-1100 unit is now ready to have power turned on. (Section 7) Page 22

23 Step 10. Step 11. Adjust the lasers to Z and Y planes using tilt and rotation adjustments. (Section 8.2) Replace front covers. Note: Before applying power to the system, remove the Maxx-1100 unit cover from each actuator and confirm that the strapping tape that secures the laser carriage during shipment has been removed WALL MOUNTING For Pivot-bracket mounting, the laser(s) must be placed in the correct laser reference plane. The pivot-brackets included have pivoting angles in two directions and linear adjustment slots in two directions, and an adjustment channel located in the frame of the Maxx-1100 unit. (Figure 4.1) Step 1. Place the pivot-bracket mounting template (with Laser Travel Zero) aligned +/-5mm to isocenter. Step 2. Mark, drill and tap holes for pivot-bracket mounting hardware (M6 bolts), if mount plate was installed. If U-channel was installed, use a M6 channel nut / strut nut to connect pivot-bracket. Step 3. Split the pivot-bracket by removing the middle bolt. So one part is still connected to the Maxx-1100 unit and the second half is free to mount to the wall. Step 4. After mounting the half pivot bracket to the wall, position the Maxx-1100 unit and reconnect the halves of the pivot-bracket. Step 5. Adjust the pivot-brackets so that the Maxx-1100 unit is square and level, and that the Laser Travel Zero is aligned to the opposite Maxx-1100 unit. Step 6. Tighten the pivot-brackets in this position. Repeat for other unit. Step 7. To verify that the Laser Travel Zero of the two Maxx-1100 units is aligned, use any line-generating device to project a line on the Laser Travel Zero indicator stickers. This projected line should intersect the reference stickers, if not repeat Step 5. Step 8. The Maxx-1100 unit is now ready to have power turned on. (Section 7) Step 9. Remove front cover. Step 10. Adjust the lasers to Z and Y planes using tilt and rotation adjustments. (Section 8.2) Step 11. Replace front covers. Note: Before applying power to the system, remove the Maxx-1100 unit cover from each actuator and confirm that the strapping tape that secures the laser carriage during shipment has been removed. Page 23

24 6.4.3 CEILING MOUNTING A ceiling mount system is required, the recommended system is U channel mount which can be installed so that its long axis is parallel to the Y line in the system and an X-Axis will give full flexibility, also a plate could be mounted to the U-channel for added support (Hospital Contractor Installed). (Figure 5.1) The pivot-brackets included have pivoting angles in two directions and linear adjustment slots in each plate and an adjustment channel in the frame of the Maxx-1100 unit. Step 1. Use a M6 channel nut/strut nut to connect pivot brackets. Step 2. Split the pivot-bracket by removing the middle bolt. So one part is still connected to the Maxx-1100 unit and the second half is free to mount to the U channel. Step 3. After mounting the half pivot bracket to the U channel, position the Maxx unit and reconnect the halves of the pivot-bracket. Step 4. Adjust the pivot-brackets so that the Maxx-1100 is level in both directions, and that the Laser Travel Zero is aligned to the treatment couch centre. Step 5. Tighten the pivot-brackets in this position. Step 6. The Maxx-1100 unit is now ready to have power turned on. (Section 7) Step 7. Remove front cover. Step 8. Adjust the lasers to X and Y planes using tilt and rotation adjustments. (Section 8.2) Step 9. Replace front cover. Note: Before applying power to the system, remove the Maxx-1100 unit cover from each actuator and confirm that the strapping tape that secures the laser carriage during shipment has been removed. SECTION 7: MAXX-1100 CONNECTIONS 7.1 MAXX-1100 UNIT POWER-UP Each Maxx-1100 unit has a detachable main power supply cord; the on switch is located near the entry point of this cord. Plug in unit with the switch in the off position then switch unit on. Refer to Section for the Maxx-1100 unit start sequence at power-up. Automatic powerup procedures are executed any time power is applied to the Maxx-1100 unit. Note: The power input also contains a replaceable fuse which Cemar Electro recommends replacing with a rated 2.0A fuse. Page 24

25 Before applying power to the system, remove the Maxx-1100 unit cover from each actuator and confirm that the strapping tape that secures the laser carriage during shipment has been removed. 7.2 SYSTEM CABLE CONNECTIONS (With Optional Computer for Dicom Protocol) Before you can finalize the install of the Maxx-1100 system the following system connections must be made, the Maxx-1100 unit(s) be powered on, and their position appropriately situated. The power cords connect to the power connection on the controller (PC) and router. The Maxx-1100 unit(s) and controller (PC); connected to the router. The system cable connections can be seen in Figure 7.1. Figure 7.1 System connection 7.3 SYSTEM CONTROLLER POWER-UP The system controller provides control to the entire MAXX-1100 system. Power is applied by turning on the power switch on the control enclosure (PC); then run the Maxx-1100 control software. Power-up operations for the system controller and for the remote control are outlined in Section Page 25

26 SECTION 8: SYSTEM ALIGNMENT 8.1 BASIC LASER ALIGNMENT CONCEPTS The following basic principles apply to alignment of laser lines independent of the model or application. For each individual laser line, the following steps must be followed in sequence LASER ORIGIN POINT MUST BE IN THE CORRECT PLANE The Laser Origin Point (LOP) is the point where the laser line exits the line-generating optics on the laser module. This is typically a point at the end of the laser module, in the centre of the laser diode barrel. If more than one laser line defines a particular plane, then the LOP for each of the lasers must lie in that plane before other alignment adjustments can be made effectively TILT THE LASER PLANE TO THE CORRECT ALIGNMENT The tilt adjustment (Figure 4.2) for each laser allows the laser diode barrel to be tilted about the LOP. The LOP does not change position as a result of this adjustment. The requirements for this adjustment are slightly different for each plane in the system. Tilt adjustment cannot be made correctly until the LOP has been located accurately in the correct plane Y PLANE Lasers that form the Y plane (Figure 4.1) in the Maxx-1100 system (e.g., the fixed lasers in the Z actuators (Maxx-1100 unit#1, unit#2) and fixed laser in the X actuator (Maxx-1100 unit#3) must be tilted to be coplanar. This can be accomplished by using the tilt control on the fixed laser to move the laser line until it passes through the LOP of the laser on the opposite wall. Note: If the rotation adjustment of the two opposing lasers is not correct, then the tilt adjustment described above may not be correct. Therefore, in the case of the Y plane, it may be more efficient to adjust rotation before tilt is adjusted X PLANE The X plane (Figure 4.1) is a vertical plane. The moving laser on the ceiling mounted X actuator (Maxx-1100 unit#3) defines the X plane. The tilt control for this laser is used to adjust the X plane so that it is perfectly vertical (plumb). Page 26

27 Z PLANE The Z plane (Figure 4.1) is a horizontal plane formed by two moving lasers (e.g., the moving lasers on the Z actuators (Maxx-1100 unit#1, unit#2) mounted on either side of the treatment room couch) must be in the same horizontal plane (i.e., level across the room). If the two opposing lasers have been correctly located with their LOP in the Z plane, then the tilt control can be used to move the projected laser line until it passes through the LOP of the opposing laser ROTATE THE LASER PLANE TO THE CORRECT ALIGNMENT When the first two adjustments have been made correctly, rotation (Figure 4.2) of the laser plane should be the final required adjustment. This adjustment consists of rotating the laser line about its long axis. In the case of the Y plane, laser alignment is most effectively accomplished if rotation adjustment of the fixed lasers precedes the tilt adjustment of these lasers. Again, the requirements for this adjustment are slightly different for each plane of the system, as described in the following sections Y PLANE In the case of the two fixed lasers on either side of the couch (Z actuators Maxx-1100 unit#1, unit#2) that help define the Y plane (Figure 4.1), the laser lines must be rotated so that the lines are vertical (plumb). In the case of the optional fixed laser(s) in the ceiling mounted X actuator (Maxx-1100 unit#3) that helps define the Y plane, the line must be rotated until it is parallel with the Y plane defined in the room X PLANE (Figure 4.1) Rotation of the X line (generated by the moving laser in the ceiling mounted X actuator (Maxx-1100 unit#3)) allows it to be made perpendicular to the Y plane Z PLANE The rotation adjustment for the two moving lasers (Maxx-1100 unit#1, unit#2) that define the Z plane (Figure 4.1) for the Maxx-1100 system allow these lines to be adjusted so that the line that is generated is horizontal (level) from end to end, parallel to the treatment couch. Page 27

28 8.2 SPECIFIC LASER ALIGNMENT PROCEDURES Once power to the Maxx-1100 units has been established (see Section 7 for more details on system and power connections) and the moving lasers are positioned to the Laser Travel Zero position, final system alignment can take place as follows: Step 1. Locate each moving laser or fixed laser in the system so that the LOP for each laser is accurately located in the correct plane. Step 2. Use tilt and rotation controls to align laser lines so that the vertical and horizontal lines are aligned with their respective counterpart. Step 3. Adjust the zero position of the moving laser on each actuator so that the laser corresponds with the isocenter and that the Maxx-1100 unit#1 and Maxx-1100 unit#2 are aligned at the same zero position LOCATING THE LOP FOR ALL MAXX-1100 SYSTEM LASERS IN THE CORRECT PLANE The purpose of this task is to physically move the lasers so that the LOP of each laser is in the correct plane. Once the LOP of all the lasers are correctly positioned, the rotation and tilt of each fixed laser can be adjusted so that all the laser lines in the room fall within the correct plane. Note: This task must be completed accurately; otherwise subsequent adjustment(s) cannot be made correctly. The procedures for this task vary depending on the equipment that is being used to align the Maxx-1100 system LOP LOCATION OF MAXX-1100 USING A ROTATING LASER The primary purpose of the rotating laser in this procedure is to locate the fixed lasers and moving lasers in all units in the correct plane. (Figure 4.1) Z PLANE Is easiest done using a rotating laser, set up at the isocenter Z plane (horizontal orientation) on the treatment room couch. (Figure 4.1) Position the Z actuators (Maxx-1100 unit#1, unit#2) laser line in the correct vertical position. The vertical position of the moving lasers must be adjusted so that the rotating laser passes through their LOP. After positioning use the remote control to set this as the new zero position. (When using the save feature all three Maxx-1100 units positions are updated.) Page 28

29 Y PLANE A rotating laser can be used to locate the LOP for the fixed lasers that form the Y plane in the Maxx-1100 system. For a Maxx-1100 Unit#3, with no fixed laser, or with three Maxx-1100 units that includes the fixed laser. This is accomplished as follows: Step 1. Set up the rotating laser at the isocenter in the Y plane. (Figure 4.1) Step 2. Reposition linearly (+/-10mm from its centre point) the fixed laser(s) until the rotating laser passes directly through the LOP. Repeat for each fixed laser ALIGNING LASERS IN THE Y PLANE Aligning lasers in the Y plane(figure 4.1) is usually the most difficult part of Maxx-1100 system alignment because you must align all three fixed lasers in this plane (If Maxx-1100 unit#3 is equipped with a fixed laser). Again, this can only be accomplished successfully if the LOP for these three lasers has been located correctly in the Y plane, as described in the previous procedures (Section 8.2.1). Once this LOP is correct for all three lasers, use the tilt and rotation controls for the lasers for final alignment ALIGN THE FIXED LASER Depending on the alignment tools that are being used, some of the steps outlined below may have been completed in previous procedures. Step 1. Set up the rotating laser at the isocenter in the Y plane. (Figure 4.1) Step 2. Use the rotation controls on the fixed lasers of Maxx-1100 unit#1 and unit#2 to make both project lines vertical. This can be done by making the lines parallel to the rotating laser line, or to the marks for the Y plane on the opposite wall, or using a plumb bob. Step 3. Use the tilt control on the fixed lasers of Maxx-1100 unit#1 and unit#2 to move the line until it is directly on top the rotating laser line, or marks on the floor that identified the Y plane. Step 4. Use a plumb bob to verify that the plane of the laser is vertical. If the plane is vertical and the plumb bob is held in the laser plane, the laser will simultaneously illuminate the entire length of the plumb bob string. Step 5. If the laser line is not vertical, then the LOP of the fixed laser is not located in the same vertical plane as the isocenter, and corrective steps must be taken to locate the LOP of this laser correctly (Section 8.2.1). Step 6. Use the rotation control on the Maxx-1100 unit#3 fixed laser to adjust the line until it is parallel with the two lines from unit#1 and unit#2. Page 29

30 Step 7. Use the tilt control on the Maxx-1100 unit#3 fixed laser to move the line until it is directly on top of the lines from unit#1 and unit#2 and the rotating laser line, or passes through marks on the floor that identified the Y plane. At this point, all three fixed lasers that define the Y plane for the Maxx-1100 system should be coplanar. This can be confirmed with a piece of white paper, and verifying that when one laser is obstructed at any given time or position in the room, the position of the line on the paper does not change. If this is not the case, revisit the preceding alignment steps to determine which was not carried out correctly or with sufficient accuracy ALIGNING LASERS IN THE Z PLANE Only two lasers are involved in aligning lasers in the Z plane (Figure 4.1); the process is thus simpler than that required for aligning lasers in the Y plane. The same principles do apply. Once the LOP for the two lasers involved is correct, then only rotation and tilt adjustments need to be made ALIGN THE MOVING LASERS Correct laser alignment requires that the laser LOP is first correctly set. The ability to move the Z lasers on the Maxx-1100 will be used, some of the steps outlined below may have been completed in previous procedures. Step 1. Set up rotating laser at the isocenter Z plane (horizontal orientation) on the treatment room couch. (Figure 4.1) Step 2. Start with both moving lasers (Maxx-1100 Unit#1 and Unit#2) at the laser travel zero, move each laser until the rotating laser passes through their LOP. Use the remote control to set this as the new zero position. (When using the save feature all three Maxx-1100 units positions are updated.) Step 3. Use the rotation control on the moving laser in the Maxx-1100 unit#1 to adjust the line parallel to the rotating laser line defining the Z plane, or so that it is parallel to the marks on the opposite wall. Step 4. Use the tilt control on the moving laser in the Maxx-1100 unit#1 to move the line until it is directly on top the rotating laser line that defines the Z plane, or both marks on the opposite wall. Step 5. Use the rotation control on the moving laser in the Maxx-1100 unit#2 to adjust the line parallel to the rotating laser line defining the Z plane, or so that it is parallel to the marks on the opposite wall. Step 6. Use the tilt control on the moving laser in the Maxx-1100 unit#2 to move the line until it is directly on top the rotating laser line that defines the Z plane, or marks on the opposite wall and through the LOP of the Maxx-1100 unit#1 moving laser, and are coplanar with each. Page 30

31 At this point, the two moving lasers that define the Z plane for the Maxx-1100 system should be coplanar. If the two Z lasers are not co-planar at this point, you must determine which of the preceding alignment steps was not carried out correctly or carefully enough ALIGNING THE LASER IN THE X PLANE There is only a single moving laser to align, the moving laser in the ceiling-mounted Maxx unit#3. This process is as follows: Step 1. Set up rotating laser at the isocenter X plane defined by a line on the installation phantom that is marked perpendicular to the Y plane in the system. (Figure 4.1) Step 2. Start with the moving laser (Maxx-1100 Unit#3) at the laser travel zero, move the laser s LOP close to the centre of the treatment couch, and use the remote control to set this as the new zero position (When using the save feature all three Maxx-1100 units positions are updated. Make sure that Maxx-1100 unit#1 and unit#2 moving lasers have not been moved from the isocentre). Step 3. Use the rotation control to rotate the laser until it is parallel to the X plane in the system. Step 4. Use the tilt control on the Maxx-1100 unit#3 moving laser to adjust the laser until it is vertical. Use a rotating laser line, or a plumb bob to verify that the plane is vertical; the laser will simultaneously illuminate the entire length of the plumb bob string FINAL ALIGNMENT VERIFICATION All lasers that define the X plane, Y plane, and Z plane for the Maxx-1100 system should be coplanar. This can be confirmed with a piece of white paper, and verifying that when one laser is obstructed at any given time or position in the room, the position of the line on the paper does not change. If this is not the case, revisit the preceding alignment steps to determine which was not carried out correctly or with sufficient accuracy. Page 31

32 SECTION 9: REMOTE CONTROL USER GUIDE 9.1 POWERING UP THE SYSTEM Each Maxx-1100 has a detachable mains supply cord, replacement cords should have A minimum 10 A Rating grounded 18AWG cord. The on switch is located near the entry point of this cord. Plug in unit with the switch in the off position then switch unit on. The power input also contains a replaceable fuse which Cemar Electro recommends replacing with a rated 1.0A fuse. The following instructions outline how to initialize power to the remote control CHARGING REMOTE CONTROL The remote control is a battery-powered handheld electronic device. Before first time use, charge the remote as follows: Step 1. Place the charging board on a flat, clean surface and plug it in to a power outlet. Step 2. Gently insert the remote control into the charging slot. The charging LED will turn red. Step 3. Leave remote control in charger until the charging LED turns green. This may take several hours. Once the LED is green, the remote control battery is fully charged. Note: The remote control uses a 3.6 Volt Lithium ion battery return damaged or no longer used Remotes to Cemar Electro for proper disposal. Note: Whenever possible, rest the remote control on the charging board to ensure the battery is constantly charged POWERING UP REMOTE CONTROL Power the remote control on by toggling down the switch at the bottom of the remote control. Allow approximately 10 seconds before the Start page appears on the screen. Page 32

33 9.1.3 LASER UNIT DISPLAYS Figure 9-1. LED Display Panel on top of MAXX-1100 unit. These LEDs indicate status of different modules of the unit. WARNING: Repeatedly turning on and off the laser units can cause damage to your laser units. Unit Number Display: This 8-segment LED displays the unit number, which should be 1, 2, or 3 for this revision. No two units can have the same unit number in a single room. System LED: The green LED indicates the system status of the unit. It is dark during calibration at power up and turns solid green when calibration is successfully completed. It blinks in different patterns indicating errors encountered during calibration or regular operation. Refer to Table 9-1 for details about System LED blinking. Ethernet LED: The amber LED indicates status of Ethernet connection between the unit and the router. Solid amber indicates the connection is correctly established. A dark LED indicates there is no valid Ethernet connection between the router and the unit. It starts blinking when Ethernet initialization and static IP address assignment cannot be completed. Zigbee LED: The red LED indicates status of Zigbee wireless connection between the unit and the remote control. Solid red indicates the connection is correctly established. A blinking LED means the connection cannot be established. During power up, the following events should occur in order. Step 1. Lighting Unit Number Display will become illuminated. Step 2. Establishing wireless connection: Zigbee LED starts blinking, indicating the unit firmware is searching for a remote control with the same PAN ID. Zigbee LED turns solid red once it is connected to the remote control. Step 3. Starting laser beams: Both the fixed and movable lasers start beaming. If laser beams cannot be started, the subsequent events will not occur. Step 4. Establishing Ethernet connection: Ethernet LED is solid amber if the unit is connected to a router via Ethernet cable; otherwise, the Ethernet LED is off. If neither wireless connection nor Ethernet connection can be established, the subsequent events will not occur. Page 33

34 Step 5. Encoder checking and calibration: The movable laser starts moving in the negative direction (i.e., moving further away from the fixed laser). It changes direction when it hits the stopper on the negative end. The movable laser will travel the length of the encoder rail and hits the stopper on the positive end, close to the fixed laser. If no error is detected during the process, System LED becomes solid green indicating the calibration was successful. Step 6. Moving to CT zero: The movable laser keeps moving towards CT zero, if available. At initial power up, the laser will remain at the positive end as CT zero has not yet been established. Refer to Section for instructions on how to set up CT Zero of MAXX-1100 system. Step 7. Following successful completion of the above steps, the laser unit is ready to accept commands from desktop application via the Ethernet interface and/or from remote control via the Zigbee interface. Table 9-1. Summary of LED blinking patterns during laser unit power up Code Blinking LED Blinking Pattern (per second) Cause Z0 E0 Zigbee LED Ethernet LED Zigbee module in the laser unit cannot connect to remote control Fails to assign static IP address based on unit number E1 System LED Fails to detect encoder zero E2 System LED Receives bad data signal from encoder E3 System LED Motor has jammed Note: In case of code E0, E1, E2, or E3, and/or associated blinking, contact Cemar Electro Inc. immediately to provide error information to technical support personnel. Page 34

35 9.2 REMOTE CONTROL OPERATION The Start page (Figure 9-2) is the entry point to all the operations on the remote control. Figure 9-2. Start page PAN ID BOX Each remote control and all the laser units in the same room share a network ID. If multiple rooms are equipped with MAXX-1100 units, each room has a unique network ID. The network ID of each remote control is displayed at the bottom of the screen. Page 35

36 Figure 9-2. Start page. Depicts a PAN ID Box noting PAN 11, which means this remote control has a network ID of 11. The PAN ID of remote control is configurable. Refer to Section for more details LASER OPERATIONS ICON The remote control must verify connection to a laser unit via Zigbee protocol before sending any commands. Refer to Section to learn how to check wireless connection and to laser units and retrieve status data from connected units. Refer to Section 9.2 to learn how to use the remote control to perform various operations on connected units REMOTE CONTROL SETTINGS ICON You may also check status and update important configurations of the remote control itself. Section 9.2 provides more details. Page 36

37 9.2.4 GENERAL USE OF REMOTE CONTROL Remote Control Elements Name Navigation icons Icons and Descriptions Located at the upper left corner of the screen. previous page Appears at the up right corner of the screen and indicates status of operation on the selected laser units. The remote control and lasers are ready. Status bar The latest laser operation is in process. IMPORTANT: DO NOT touch the screen while the remote is in this state. If it lingers in this state much longer than the estimated time, restart the remote control. The latest laser operation has succeeded. The latest laser operation has failed. Refer to Section Error! Reference source not found. for troubleshooting instructions. For all the operations, wait until the status bar turns from yellow to green or red before you click the next icon. Note: It takes about one second for a single unit to process and reply to a non-lasermoving command. If a command is sent to all the connected units, it takes up to three seconds for the remote control to receive and process replies from all the units. For laser-moving commands, the responding time naturally depends on the distance that lasers have to travel. 9.3 LINKING AND STATUS CHECKING The following details how to link units and check their status WIRELESS COMMUNICATION STATUS There are three laser units in a fully equipped MAXX-1100 Laser System. The remote control checks laser units in the same network automatically every time when it enters the Connection page from the Start page. The Laser Status Checking page on the remote control will display as shown in Figure 9-3if any of the following cases applies: Page 37

38 Remote control has just been powered up PAN ID of the remote control has just been changed Laser connection status has just changed (e.g. new units have joined network or existing units have left network) Figure 9-3. Connection page; all lasers are connected LASER STATUS INDICATORS The most important information on Connection page are the Laser Status indicators. These indicators can display the following: : This laser is connected. : This laser is not connected. Figure 9-4 shows all three MAXX-1100 laser units connected in the wireless network of remote control. If only Unit #3 is connected, the Laser Status Indicators will display as. Laser operations will be available only on the Unit #3 laser. If none of the lasers are connected, the Laser Status indicators will display as. No operation is available if none of the three lasers is connected CHECK STATUS ICON Click Check Status icon to update status of laser units, including the current position, speed and power settings, and zero-point settings of every connected unit. This icon is always available regardless the status of wireless connections. 9.4 LASER UNIT STATUS If at least one laser is connected, click Check Status icon to bring up the Laser Operation icons on the Laser Operation page, as shown in Figure 9-4. Page 38

39 Figure 9-4. Laser Operation page LASER STATUS INDICATORS Laser status indicators are updated based on the result of status checking. : This laser has reported its status and it is calibrated. All the operations are available on this unit. : This laser has failed to report its status or it is not calibrated. All the position-related operations are disabled on this unit. Laser power and speed configuration is still available. Page 39

40 9.4.2 LASER OPERATIONS ICONS Click one of the following Laser Operation icons to open the corresponding laser operation page. Each icon is referenced to a section where group operations are detailed in full. Home/CT Zero operations (Section 9.5) Zero Point settings (Section ) Laser Configuration(Section 9.6) Laser Line Positioning (Section9.7) Express Points operations (Section 9.8). These operations are only available when the current reference system is based on CT Zero (See details in Section 9.5). You may refresh laser status at any time. 9.5 HOME/CT ZERO OPERATIONS Figure 9-5 shows an example of CT Zero page of the remote control. This page shares many common elements with other position-related pages including Zero Settings page, Laser Position page, and Express Point page. These elements are explained in detail in this section. Figure 9-5. CT Zero page: Reset zero. Page 40

41 9.5.1 CURRENT ZERO BOX The Current Zero box displays the current setting of the reference system. Three possible reference systems are based on a zero-point setup: CT Zero: Zero point of MAXX-1100 system is aligned with CT machine zero. PAT Zero: Zero point of MAXX-1100 system is set to be a temporary point other than CT machine zero. Reset Zero: Zero point of MAXX-1100 system is set to be reset zero, which is the absolute zero point in the middle of the encoder rail. A group of operations are dedicated to switching between different zero systems, as introduced in Section Current Zero box can also be found at the same location on Zero Settings page, Laser Position page, and Express Point page. Any zero setting change on one of these pages will update Current Zero box on all of these pages UNIT-AXIS SELECTION Click the Unit-Axis Selection icon multiple times to work with all the connected units one by one. The same icon also appears on Zero Settings page and Laser Position page for unit-axis selection. In a fully-installed MAXX-1100 system, there are three possible unit-axis selections. 1-Z1: the movable laser on Unit #1. 2-Z2: the movable laser on Unit #2. 3-X: the movable laser on Unit #3. Click the Unit-axis Selection icon repeatedly to go through the above unit-axis selections sequentially. If one laser unit is not connected to the remote control, the corresponding unit-axis selection will be skipped CURRENT LASER POSITION This text field shows the current position of selected unit-axis, relative to current zero setting. The following rules apply to all the laser position displays on the remote control. All the position values are in unit of millimetre (mm). A positive position value means the laser is closer to the fixed laser on the same unit compared to current zero point. A negative value means the laser is further away from the fixed laser compared to current zero point. A value of zero means the laser is right at current zero point. The position text becomes >>>>>> while the lasers are moving. Page 41

42 9.5.4 LASER MOVING ICONS These icons send commands to the selected laser only. Current Laser Position will be updated upon completion of any movements. The same group of icons also appear on the Zero Settings page. Click the icon once to move the selected laser one step towards the negative direction. Click the icon once to move the selected laser one step towards the positive direction. Press and hold the icon to move the selected laser towards the negative direction; release the icon to stop the movement. Press and hold the icon to move the selected laser towards the positive direction; release the icon to stop the movement. Note: The remote control will ignore the command if the operator clicks the icons faster than twice per second. It takes about one second from sending a command to a unit to getting a positive reply from the unit, excluding time of laser movement. Clicking laser moving icons too fast does not speed up the process CT ZERO FUNCTION ICONS Save CT Zero: Save current position as CT Zero point on all connected lasers. Go Home: Move all connected lasers back to CT Zero point. This icon is hidden if CT Zero point is not set SET CT ZERO POINT All MAXX-1100 units from Cemar Electro Inc. have been set to Reset Zero before shipping. At the first power-up after installation, the movable laser stops at the furthest positive end of the rail after calibration. The first step to complete immediately following mechanical installation is to set CT Zero on all the installed units. On the remote control, Figure 9-6 shows the CT Zero page at the first power up. Current Zero box displays Reset Zero. Current Laser Position shows the position relative to the mechanical zero point. This value is the distance from the mechanical zero point to the stopper at the fixed laser side, where the movable laser is stopped after encoder calibration. This distance is slightly different on each unit. Page 42

43 Figure 9-6. CT Zero page: First power up. Figure 9-7. CT Zero page: Laser 1-Z1 is aligned to CT Zero. The operations to set a new CT Zero point include two steps: Moving lasers to the desired coordinate and saving the coordinate as the new CT Zero. Step 1. Align lasers to CT machine zero. Select a unit-axis, and use the laser moving icons to align this laser to CT machine zero on the corresponding axis (Figure 9-6). Select next unit-axis and repeat until all the connected lasers are aligned to CT machine zero (Figure 9-7). Step 2. Save current laser position as CT Zero. Click the Save CT Zero icon to save the current coordinate as CT Zero point of the reference system (Figure 9-8). The Save CT Zero command is sent to all connected laser units (Figure 9-9). This command overwrites the existing CT Zero settings on laser unit firmware, if any. Figure CT Zero page: Saving new CT Zero. Figure CT Zero page: New CT Zero has been set. Page 43

44 Upon successful completion the status bar will turn green. Current Laser Position becomes 0.0 mm for all connected lasers. The Current Zero box displays CT Zero. The previously hidden Go Home icon appears. Now CT Zero has been set. CT Zero can be updated as many times as needed. The procedure is the same HOMING LASERS TO CT ZERO At any point lasers need be returned to CT Zero point, simply open Laser Home page and click Go to Homeicon(Figures 9-10, 9-11). The Go to CT Zero command is sent to all connected lasers; each moveable laser will return to the saved CT Zero position and stop. The remote control updates Current Laser Position to be 0.0 mm for all lasers. Figure CT Zero page: Away from CT Zero. Figure CT Zero page: Back to CT Zero CHANGING ZERO SETTINGS Laser reference system can be switched between CT Zero, Patient Zero, and Reset Zero. Note: Remember that the MAXX-1100 system works in CT Zero reference system by default at power up, if CT Zero has been set. Any Patient Zero settings will be lost at power cycle. If you wish to keep certain coordination persistent after power cycle, use the Express Point settings (Section 9.8). Page 44

45 Figure Zero Settings page. The Zero Settings page (Figure 9-12) is very similar to the Laser Home page. The only difference is the Zero Settings icons ZERO SETTINGS ICONS Switch to CT Zero. See details in Section Switch to PAT Zero. See details in Section Reset Lasers. See details in Section Page 45

46 SWITCHING FROM CT ZERO TO PATIENT ZERO The procedure to switch reference system from CT Zero to Patient Zero is similar to setting new CT Zero point. Figure Zero Settings page: Moving lasers to desired coordination. Figure Zero Settings page: New PAT Zero saved. Step 1. Move lasers to a designated coordination. Select the laser axis with the Axis Selection icon. Move the selected laser to desired position with Laser Moving icons on this page or specifying target position on Laser Position page (Section 9.7). Repeat until all the lasers have moved to the future zero point. In the example of Error! Reference source not found.figure 9-13, the movable laser of Unit #1 is moved to mm on the X axis in the CT Zero reference system. We assume that the movable lasers on the other two units have also been moved to the designated coordination. Step 2. Save current laser position as PAT Zero point and switch reference system to PAT Zero. Click the Switch to PAT Zero icon; the Switch to PAT Zero command is sent to all three units. Each unit updates their own zero settings and current laser position based on new zero point. Upon receiving positive replies from the units, the remote control updates related UI components on Zero Settings page: PAT Zero in Zero Settings box and 0.0 mm in Current Laser Position (Figure 9-14). The operator can click the Axis Selection icon to check position updates of other lasers. From now on, all the position values are based on the saved PAT Zero point, until the operator switches the reference system to be based on another zero point. Page 46

47 SWITCHING FROM CT ZERO/PATIENT ZERO TO RESET ZERO During installation or maintenance procedure, it may be necessary to move lasers to their Reset Zero positions. One click on Reset icon will drive all connected lasers to the middle point of their rails. The time duration for this operation depends on where the CT Zero is from Reset Zero. Figure Zero Settings page: CT Zero. Figure Zero Settings page: Lasers are at Reset Zero. When lasers are at CT Zero point (Figure 9-15), the operator will click the Reset Lasers icon, and the movable lasers start to move towards the mechanical zero point. Once the lasers arrive at the zero point, the units send replies to the remote control, which updates related UI elements on Zero Settings page (Figure 9-16). At this time, the Zero Settings box will display Reset Zero; the current position is 0.0 mm relative to Reset Zero. The Reset Lasers and Switch to PAT Zero icons are hidden because these functions are not applicable when the reference system is based on Reset Zero. Page 47

48 SWITCHING FROM PATIENT ZERO/RESET ZERO TO CT ZERO To switch back to CT Zero reference system, click Switch to CT Zero icon and wait for the command to be completed. Figure Zero Settings page: Lasers are at Reset Zero. Figure Zero Settings page: Reference system is switched back to CT Zero. When the movable lasers are at Reset Zero point and the reference system is based on Reset Zero point, the operator will click the Switch to CT Zero icon, and the remote control sends the Switch to CT Zero command to all lasers (Figure 9-17). The firmware on each unit switches the reference system to CT Zero, and calculates the current position relative to CT Zero. The remote control updates the UI upon receiving positive replies from the units. The updated position of movable laser will be displayed (Figure 9-18). The Reset Lasers and Switch to PAT Zero icons appear again because the lasers are in the CT Zero reference system, indicated in Zero Settings box. Note: Lasers will not move during the switch from Patient Zero/Reset Zero to Ct Zero. Only the reference system is switched. The operation is the same to change reference system from PAT Zero to CT Zero. Page 48

49 9.6 LASER CONFIGURATION / ADJUSTMENT Click the Laser Configuration icon to open the Laser Power page(figure 9-19). Figure Laser Power page NAVIGATION ICONS Return to Laser Functions page. Jump to Laser Speed page UNIT SELECTION ICONS This unit is connected and selected. This unit is connected but not selected. This unit is not connected. By default, all the connected units are selected. Click the Unit Selection icon to select the current unit only; click the icon a second time to select all the connected units POWER LEVEL GRID The number of green cells in the power level grid corresponds to the power level setting of the lasers on this unit. By default, all lasers are powered up at level 4 (Figure 9-19). Power level can only be adjusted individually on the selected unit. Page 49

50 POWER FUNCTION ICONS Note: Power of multiple lasers on the same unit cannot be independently adjusted or switched. Power-on: Turn on the laser beam of selected unit(s), available when at least one selected laser is off. Power-off: Turn off laser beam of selected unit(s), available when at least one selected laser is on. Power-down: Decrease laser power by one level on selected unit, only available when a single unit is selected and its lasers are beaming. Power-up: Increase laser power by one level on selected unit, only available when a single unit is selected and its lasers are beaming. Typical laser power functions are illustrated below. Switch laser power on all units. Click the Power-on icon to turn on all connected lasers (Figure 9-20). Click the Poweroff icon to turn off all connected lasers (Figure 9-21). Figure Laser Power page: All lasers are beaming. Figure Laser Power page: No laser is beaming. Page 50

51 Switch laser power on a single unit. Click the Unit Selection icon to select the unit (Figure 9-22) and click the Power-off icon or the Power-on icon to switch power of the lasers on the selected unit (Figure 9-23). Figure Laser Power page: Unit #3 is selected. Figure Laser Power page: Lasers on Unit #3 are beaming. Adjust laser power level on a single unit. The two power adjustment icons will appear if the selected laser is currently beaming. The effect is immediate and persistent (i.e. this laser will beam at the same level of brightness even after a power cycle). The remote control always displays the updated information on laser power status. In the example of Figure 9-24, the lasers on Unit #3 are beaming at power level 4. The operator clicks the Power-up icon twice to increase the power level to 6, as shown in Figure The same procedure applies if the laser power level needs to be reduced. Figure Laser Power page: Lasers on Unit #3 are beaming at level 4. Figure Laser Power page: Lasers on Unit #3 are beaming at level 6. Page 51

52 9.6.3 LASER SPEED ADJUSTMENT Click the Laser Configuration icon to open the Laser Speed page (Figure 9-26). Figure Laser Speed page: Factory settings SPEED BAR Laser moving speed can be set to five different levels. The default speed is medium, about 40 mm/second. Laser moving speed can be adjusted individually on the selected unit or on all the connected units (Figure 9-26). If a laser unit is not connected, the speed bar is hidden SPEED FUNCTION ICONS Speed-up: Increase moving speed of movable laser on selected unit(s) by one level. Slow-down: Decrease moving speed of movable laser on selected unit(s) by one level. Save Changes: Send any speed adjustment command to selected unit(s). Page 52

53 Typical usages of laser power functions are explained and illustrated below. Adjust moving speed of movable lasers on all connected units. With all the unit icons in selected mode, click Speed-up or Slow-down icon to change the moving speed. The Save Changes icon appears when there is any change. Then click Save Changes icon to send command to all connected units to actually change the speed settings on laser unit firmware. Any unsaved changes will be ignored. In the example of Figure 9-27, the operator will click the Speed-up icon twice to change moving speed to Fastest. There is no color change in status bar because these changes are only on remote control side for now. The Speed-up icon is hidden because the tentative speed is already at the maximum value. Similarly, Slow-down icon will be hidden if the current or tentative speed is at the minimum value. The operator will click the Save Changes icon to send commands to all the units to complete the operation. As shown in Figure 9-28 the movable lasers on all the units will move at the highest speed from now on. Figure Laser Speed page: Changing speed to fastest. Figure Laser Speed page: Speed change is saved. Page 53

54 Adjust moving speed of movable laser on a single unit. Click the Unit Selection icon to select a single unit; click the Speed-up or Slow-down icon to set value of desired speed. Finally click the Save Changes icon to send the Save Changes command to the selected unit to complete the operation. If the operation is successful, the movable laser on the selected unit will move at the new speed in the future. In the example of Figure 9-29, Unit #3 is selected. The current speed is Highest. The operator changes the setting to Slower, as shown in Figure Figure Laser Speed page: Figure Laser Speed page: Unit #3 is selected. Set new speed for Unit #3 9.7 LASER LINE POSITIONING The operator can specify a target position for the movable lasers and fine tune the final positions with micro-stepping functions (Figure 9-31). Figure Laser Position page. Page 54

55 9.7.1 NAVIGATION ICONS Return to Laser Functions page. Jump to Express Points page. Move Lasers. Click this icon to send the Move to Target command to all connected lasers if input target position value is valid for each selection. All lasers that receive this command will move to target position and send reply message to the remote control, reporting their current position. Micro-stepping. These icons are not available for axis selection Z1 = Z AXIS SELECTION ICON Click the Axis Selection icon to select next available laser-axis in order to input target position value or use micro-stepping icons to adjust the final position of the selected laser-axis. There are four possible Axis Selection options: Z1=Z2, 1-Z1, 2-Z2, and 3-X. In most cases, Z1 and Z2 are both aligned to the Z axis of CT Zero. The operator can therefore specify one target position for both Z1 and Z2. However, it is also possible to specify different target positions for Z1 and Z CURRENT LASER POSITION The current position value is based on current zero setting, which is shown in the Zero Setting box on the Laser Home page. If Z1 and Z2 are not at the same position, the Current Position shows N/A when axis selection is Z1 = Z2. For all the other axis selections, the Current Position shows a valid position value or N/A if the remote control has no knowledge of valid position value of the selected laser-axis. In the example of Error! Reference source not found.figure 9-31, the movable laser of Unit #1 is at position 0.0mm (i.e., aligned with CT Zero). Page 55

56 9.7.4 USER INPUT ICONS The operator can use the digits, negative sign, and dot icons on the remote control to enter a positive or negative value as the target position for selected laser. Clear Input icon: This icon will clear all the input LASER POSITIONING Typical usages of laser position functions are explained and illustrated below. Move lasers to a target position. Select a laser-axis, and provide a valid target position. Repeat this step until target positions are specified for all the available selections of laser-axis. Click Move Lasers icon to move all connected lasers. Wait until the remote control receives replies from all lasers. Figure Laser Position page: Figure Laser Position page: Z1 = Z2 selected. Input for Z1 = Z2. In the example of Figure 9-32, Z1 and Z2 are initially at CT Zero point. The operator will enter the target position 79.5for the Z axis, as shown in Error! Reference source not found.figure The operator will click the Axis Selection icon twice, to check that target position for Z1 and Z2 are both Clicking the Axis Selection icon again will select 3-X, as shown in Error! Reference source not found. Figure Page 56

57 Figure Laser Position page: Input for 3-X. Figure Laser Position page: All lasers moving to target. The operator will then click the Move Lasers icon to start moving the lasers. Figure 9-35 illustrates the Laser Position page while lasers are moving towards the target. The status bar will turn yellow; Current Position will appear as >>>>>> because the remote control has no knowledge of lasers current position while lasers are moving. Figure Laser Position page: Z1 and Z2 at target position. Figure Laser Position page: 3-X at target position When lasers successfully arrive at their destinations, the status bar turns green. The current position is updated to the actual value; due to calibration, this may not be exactly the same value as the input number. The difference between the target position and the actual position is ± 0.2 mm, as shown in Figure 9-36 and Figure Invalid input for target position. If the input value is not a valid target position, the input field will show tips on how to enter a valid target position value when the Move Lasers icon is clicked. There are two types of invalidity: Input is in wrong format and input is out of range. Page 57

58 Option 1. Input is in wrong format. The input value should be a valid positive or negative decimal number. Only one digit after the decimal point is permitted because the accuracy of laser positioning is 0.1 mm. Figure Laser Position page: Input in wrong format. Figure Laser Position page: Correct input format. In the example of Figure 9-38, the operator entered an invalid target position then clicked the Move Lasers icon. The remote control checked the input string and detected the input was in the wrong format. The correct format will then display onscreen, as shown in Figure The operator will need to click the Clear Input icon to clear the input box before entering the correct target position. Option 2. Input is out of range. The moving range of each laser is 600 mm. Depending on zero-point setup, input range is calculated and given as [ zero offset, zero offset]. Figure Laser Position page: Input is out of range. Figure Laser Position page: Current input range. In the example of Figure 9-40, the operator entered a large number as the target position then clicked the Move Lasers icon. The remote control shows the current input range in the input box (Figure 9-41). The operator needs to click the Clear Input icon to clear the input box before entering the correct target position. Page 58

59 Adjust laser position in micro steps. The micro-stepping icons can be used to adjust laser positions at high accuracy of less than 0.3 mm. Each micro-step is approximately 0.2 mm of distance. Note: The first few steps after changing direction of movement may not result in any actual position updates because of motor backlash. Save current position as an Express Point. If it is necessary to move lasers to a certain position multiple times, the operator can save this position as an Express Point, allowing the lasers to move to this exact positioning the next time. Click the Go to Express Point icon to open Express Point page and follow instructions in the next section to set and visit Express Points. 9.8 EXPRESS POINTS OPERATIONS An Express Point is a user-defined point that is saved in the system. System operators can move lasers to an Express Point on one-click operation, rather than adjusting lasers to specific positions every time. You may save up to five points in the current MAXX-1100 system. You may define or clear an Express Point at any time by visiting the Express Points page (Figure 9-42) from the Laser Functions page or the Laser Position page. Figure Express Points page. Note: All Express Point positions mentioned in this section are based on CT Zero, as the Express Points operations are only available when reference system is based on CT Zero. Page 59

60 9.8.1 NAVIGATION ICONS Return to Laser Functions page. Jump to Laser Position page. Point Selection. Use these icons to select the Express Point to be manipulated. Express Points are labelled as P1, P2, etc EXPRESS POINTS FUNCTION ICONS Point Save. Point Clear. Move Lasers to Point UNIT NUMBER ICONS This unit is connected and selected. This unit is connected but not selected. This unit is not connected. By default, all the connected units are selected. Click on the Unit Selection icon to select this unit, and click it again to select all the connected units POSITION FIELDS Current Laser Position (in blue) illustrates the current position of the corresponding laser axis. Current Point Position (in red) illustrates the position value of the current point for the corresponding laser axis. If the current Point is not defined yet, Current Point Position is /, as shown in Figure Otherwise, Current Point Position displays the saved position of this Point, as shown in Figure Page 60

61 Figure P3 is selected. If a unit is not connected, Current Laser Position and Current Point Position fields are hidden EXPRESS POINTS MAIN OPERATIONS Retrieving Express Points. The remote control retrieves and displays Express Point information automatically when the operator has selected an Express Point. The remote control will retrieve Express Point information from each connected laser unit, if it is the first time the Express Points page is loaded, or the operator has clicked the Laser Status icon ( ) on the Laser Operations page (Figure 9-43). In these cases, the operator should expect a short delay when a defined Point is selected, while the remote control is loading data from laser firmware. Once the information is loaded, there should be no delay when switching between different points. Setting up Express Points on all lasers. Follow the three steps below to set up an Express Point. The operation is the same for both defining a new point and overwriting an existing point. Step 1. Move lasers into the position to be saved as an Express Point. Position the laser at the desired coordinates, following the positioning instructed detailed in Section Step 2. Select an Express Point. Open the Express Points page, and use the Point Selection icon to select an Express Point. In the example of Figure 9-44, Express Point P3 is selected. The current laser coordination is (Z1=50, Z2=50, X=-100). Page 61

62 Figure Express Points page: P3 is saved. Step 3. Save the position to the selected Express Point. Click the Point Save icon to save the current position to the selected Express Point. The Save Point command is sent to all connected lasers. Lasers do not move upon receiving this command. Each laser saves the current position to the selected Express Point and replies to the remote control to confirm the result of this operation. The Point Position fields are updated accordingly if the remote control receives positive replies from all the connected lasers. In the example of Figure 9-44, P3 is successfully defined. From now on, the lasers can move to P3 (Z1=50, Z2=50, X=-100) on one click. Moving Lasers to Express Points. The purpose of setting up an Express Point is to move lasers quickly to the position later. Follow these two steps to move laser to a defined Express Point. Step 1. Select an Express Point. Follow the same protocol as Setting up an Express Point (Section 9.8.3). Step 2. Move all lasers to the selected Point. Click Move Lasers to Point icon to send command Move Lasers to Point to all connected lasers. The lasers move to the selected Point and report the current position to remote control. In the example of Figure 9-45, the lasers are at CT Zero point and P3 is selected as the target Express Point. In Figure 9-46, all lasers have moved to P3 at one click of Move Lasers to Point icon; positioning via this function is within ±0.2 mm of the target value. If the exact position is required, use the micro-stepping functions on Laser Position page to do fine adjustment. Page 62

63 Figure P3 is selected as the Figure Laser has moved to target point. P3. Setting up Express Points on selected laser axis. In case only one laser axis needs to be defined or modified for an Express Point, the operator can set up Express Point on the selected unit only. Step 1. Move lasers into the position to be saved as an Express Point. Please use laser positioning functions on other pages, such as the Laser Position page, to move laser to the desired position. In the example of Figure 9-47, laser 3-X has been moved to position mm. Step 2. Select an Express Point. Open the Express Points page, and use the Point Selection icons to select an Expression Point. In Figure 9-48, Express Point P3 is selected. The existing position value of P3 for laser 3-X is mm. Step 3. Select a unit. Click one of the Unit Number icons to select the laser unit and its movable laser. Page 63

64 Figure Express Points page: Laser 3-X at new position. Figure Express Points page: Laser 3 is selected. Figure Express Points page: P3 of Laser 3-X is updated. Step 4. Save the position to the selected Express Point Click Point Save icon to save the current position of the selected laser to the selected Express Point. The Save Point command is only sent to the selected laser, which saves the current position to the selected Express Point and sends reply to remote control indicating the result of operation. The Point Position field of the selected laser is updated accordingly if the remote control receives positive reply. No laser movement is triggered during this operation. In the example of Figure 9-49, P3 has been updated on Laser 3-X from to Moving selected laser axis to Express Points It is also possible to move only one laser axis to a saved position without affecting other lasers. Step 1. Select an Express Point. Step 2. Select a unit. The first two steps of this operation are the same as Steps 2 and 3 of the previous operation. Page 64

65 Step 3. Move selected laser to selected Point. Click Move Lasers to Point icon to send command Move Lasers to Point to the selected laser only. The laser moves to the selected point and reports its current position to the remote control. The other lasers are not affected. In the example of Figure 9-50, the operator selects Express Point P2 on laser 3-X (i.e., the movable laser on Unit #3). The current position of laser 3-X is The operator clicks the Move Lasers to Point icon and laser 3-X moves to its P2 position of As shown in Figure 9-51, the updated position of laser 3-X is Lasers Z1 and Z2 stay at the initial position. Figure Express Points page: Figure Express Points page: P2 on laser 3-X selected. Laser 3-X arrives at P2. Clearing an Express Point definition A defined Express Point can be cleared. Please note that this operation is not available for individual laser. Step 1. Select an Express Point. Step 2. Clear the selected Point. Click Point Clear icon to clear the definition of the selected Point. In the example shown in Figure 9-52 and Figure 9-53, the definition of P3 has been cleared. No laser movement is triggered by this command. Page 65

66 Figure Express Points page: P3 is selected. Figure Express Points page: P3 has been cleared. 9.9 REMOTE CONTROL SETTINGS Click the Remote Control Settings icon on the Start page, and the remote control will open the Remote Control Settings page (Figure 9-54) immediately. Figure Remote Control Settings REVISION NUMBER BOX This box shows the revision number of remote control software. This User Guide pertains to Revision Please make sure that your remote control and all the documents have the same revision number. Page 66

67 9.9.2 BATTERY CAPACITY INDICATION Battery Capacity Indication informs users how much capacity is remaining in the battery. Both the battery capacity percentage and the battery image are updated every 30 seconds. The battery image shows green blocks if the capacity is greater than 25%. The last remaining block turns yellow if the capacity is between 20% and 25%. The last remaining block turns red if the capacity is below 20%. Low Battery Warning starts to pop up. Please refer to Section for more information about Low Battery Warning LOCAL FUNCTION ICONS There are two categories of remote control-oriented settings: Power saving settings and PAN ID configuration. Power Saving Settings: Click this icon to open Power Saving Settings page. See details in Section PAN ID Configuration: Click this icon to open Password page to enter password for PAN ID configuration. See details in Section LOW BATTERY WARNING The Low Battery Warning, as shown in Figure 9-55, starts popping up every five seconds if the battery capacity is below 20%. All the regular operations are not affected as long as the icons are not blocked by the popup. You may click the Close Popup icon to dismiss the warning, or wait five seconds until it disappears automatically. We strongly suggest that you put the remote control to a charger immediately as soon as the first Low Battery Warning shows up. If you ignore the warning and continue using the remote control without charging, the remote control will enter sleep mode automatically as soon as the remaining capacity is below 15%, which may cause service disruption and unexpected results. Page 67

68 Figure Low battery warning popup POWER SAVING SETTINGS Minimize power consumption will maximize the operation time of the remote control. Two power-saving configurations are available on the remote control (Figure 9-56):LCD-off Timer and the Sleep Timer. Figure Power Saving settings LCD-OFF TIMER SETTING The LCD-off Timer will begin counting whenever there is no user activity on the LCD screen. The backlight of the LCD screen will shut off if the LCD-off Timer expires. The default value of LCD-off Timer is 2 minutes. The operator can change it to any integer value between 1 and 10 by clicking the and icons. Page 68

69 SLEEP TIMER SETTING The Sleep Timer will begin counting whenever there is no user activity on the LCD screen. The remote control will enter sleep mode if the Sleep Timer expires. The default value of Sleep Timer is 15 minutes. The operator can change it to any integer value between 10 and 30 by clicking the and icons SAVE CHANGES ICON If any of the timer settings are changed, the Save Changes icon will appear to enable saving changes to the remote control. The new settings take effect immediately WAKE-UP METHODS Option 1. LCD-off: Tapping the touch screen at the top right corner will reactivate the LCD screen and allow users to resume previous operation. WARNING: Do not touch anywhere else to wake up the screen, control icons may inadvertently be activated, causing unwanted laser movements. Option 2. Sleep: Toggling the power switch upwards will reactivate the remote control and allow users to resume previous operation NETWORK ID CONFIGURATION This function allows operators to change PAN ID of the remote control. Cemar Electro Inc. recommends permanently associating one remote control to one set of lasers. It may, however, be practical to use one remote control to adjust lasers in multiple rooms in such cases as: If a remote control is dysfunctional. Operators may temporarily use another remote control in place of the original to ensure uninterrupted medical service. Some operators prefer to use one remote control to set up and adjust laser units in all rooms to ensure better equipment management. In any of the above cases, PAN ID of the remote control must be changed before it can be used to control lasers in the room. Please follow the steps below to switch PAN ID of a remote control. Page 69

70 PASSWORD INPUT Click corresponding digit icons to input password. All the input digits will be displayed as * in the Password Input field. Click the PAN ID Configuration icon on the Remote Control Settings page to open the Password page (Figure 9-57). The system will permit three chances to enter the correct password. After three unsuccessful trials, the remote control will disable this function and jump back to Remote Control Settings page (Figure 9-54) automatically. Figure PAN ID Configuration Password page. Step 1. Enter password. Note: Improper use of this function may cause communication chaos in multiple rooms equipped with MAXX-1100 laser units. This function is password-protected. Please contact Cemar Electro Inc. for more information. Step 2. Change PAN ID number. If password input was correct, the PAN ID Configuration page will open, as shown in Figure Figure PAN ID Configuration page. Page 70

71 Step 3. PAN ID Configuration Area The current PAN ID of the remote control is displayed on the page (Figure 9-58). Valid values of PAN ID for MAXX-1100 system include 11, 21, 31, 41, 51, 61, 71, 81, 91, A1, B1, C1, D0, E1, and F1. Contact Cemar Electro Inc. if you have more than 15 rooms to be equipped with MAXX-1100 laser systems. Step 4. Save Changes Click this icon to make the actual changes of PAN ID. The saving procedure should finish within five seconds. The status bar turns green on success and the Save Changes icon will be hidden until new changes are made, as shown in Figure Figure PAN ID Configuration page: Change is saved. Step 5. Verify new PAN ID. The new PAN ID can be verified by returning to the Main page and checking PAN ID there. Figure 9-60 shows that the current PAN ID is 31. Once this set-up is complete, the remote control is ready to send commands to laser units in the new PAN network. Figure Main page: PAN ID is updated. Page 71

Cemar Electro Inc. MAXX-1100 Laser Positioning System. Installation and Set-up Manual

Cemar Electro Inc. MAXX-1100 Laser Positioning System. Installation and Set-up Manual Cemar Electro Inc. MAXX-1100 Laser Positioning System Installation and Set-up Manual Cemar Electro Inc. 1370 55 th Avenue Lachine, QC H8T 3J8 Canada Phone: 514-631-5807 Fax: 514-631-7505 Toll free: 1-800-298-5273

More information

Centralite CT Moving Laser Patient Positioning System (MRR-1)

Centralite CT Moving Laser Patient Positioning System (MRR-1) Centralite CT Moving Laser Patient Positioning System (MRR-1) Installation and Setup Manual DIACOR, INC. 2550 DECKER LAKE BLVD., SUITE 26, WEST VALLEY CITY, UTAH 84119 800 342-2679 / 801 467-0050 / 801

More information

A NEW LASER FOCUS ON PATIENT SAFETY

A NEW LASER FOCUS ON PATIENT SAFETY A NEW LASER FOCUS ON PATIENT SAFETY PATIENT SAFETY STARTS HERE During CT Simulation, clinics rely on moveable lasers to mark where radiation will enter a patient s body to target the tumor. Fixed lasers

More information

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+ LASER SOLUTIONS Ensure Accurate Setup from Simulation to Treatment MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+ THE LEADER IN LASER ALIGNMENT Gammex was the first company to replace incandescent lightbulbs

More information

LA 90L / LA 180L. Operating instructions

LA 90L / LA 180L. Operating instructions L 90L / L 80L en Operating instructions L 80L 7 3a 5 6 4 3b 8 d b c b a a C L 80 L L 90 L D D >,8m > ft 90 Y Y m 3 3 ft E E E3 F Y D ± 5 D X D3 G,8m ft G G3 S > 5 m > 6 3 ft G4 G5 3 3 en Operating instructions

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

LDM M LASER DISTANCE MEASURER

LDM M LASER DISTANCE MEASURER LDM120 120M LASER DISTANCE MEASURER INSTRUCTION MANUAL SAFETY Read the following safety instructions before attempting to operate this product. SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE.!

More information

The Nureva Span ideation system. Installation guide. Single panoramic system

The Nureva Span ideation system. Installation guide. Single panoramic system The Nureva Span ideation system Installation guide Single panoramic system Important SAFETY WARNINGS Prior to the installation of this product, the installation instructions should be completely read and

More information

Blue Weapon Laser. User manual UK. Version 1.0

Blue Weapon Laser. User manual UK. Version 1.0 Blue Weapon Laser User manual 152.754UK Version 1.0 CAUTION 15. Disposal : Please disposal of the unserviceable device according to the current statutory requirements. Please read this manual fully before

More information

LaserLyte-Flex Red & Green Alignment System

LaserLyte-Flex Red & Green Alignment System LaserLyte-Flex Red & Green Alignment System LaserLyte-Flex The LaserLyte-Flex is an entry-level laser alignment system. It uses interchangeable optics and a semiconductor laser diode to project a highly

More information

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level Operating Manual AdirPro HV8RL Red Beam Horizontal/Vertical Laser level Maintenance and Safety The HV8RL is a class II laser according to 21CFR1040. Be careful not to expose your eyes to the laser beam.

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

Laserlyte Alignment System

Laserlyte Alignment System Laserlyte Alignment System A Global Laser Brand The LaserLyte alignment system is a unique, user adjustable, plug and play system suitable for a wide range of applications, i.e. alignment and these applications

More information

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement. www.lightware.co.za info@lightware.co.za The InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement. Able to measure to any solid surface, at any angle,

More information

icore Kiosk system Installation Guide

icore Kiosk system Installation Guide icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

Product Documentation

Product Documentation Product Documentation Emanate PowerPath TM TempTag PPT-300 Date: April 12, 2016 Document Number: PPT200-001 R1.4 Emanate Wireless, Inc. 11145 Windsor Rd. Ijamsville, MD 21754 Telephone: 844-EMANATE Email:

More information

Spectrum Laser. User manual UK. Version 1.0

Spectrum Laser. User manual UK. Version 1.0 Spectrum Laser User manual 152.753UK Version 1.0 CAUTION 15. Disposal : Please disposal of the unserviceable device according to the current statutory requirements. Please read this manual fully before

More information

TEL: / FAX:

TEL: / FAX: Self-leveling Rotary Laser FRE-211 Operating Manual P.R.Engineering Ltd UK www.laser-level.co.uk TEL: 01246 269 777 / FAX: 01246 260 007 SAFETY PRECAUTIONS: During instrument operation, be careful not

More information

SPL-100 BATTERY-OPERATED LASER OPERATOR S MANUAL

SPL-100 BATTERY-OPERATED LASER OPERATOR S MANUAL SPL-100 BATTERY-OPERATED LASER OPERATOR S MANUAL BinMaster: Division of Garner Industries 7201 N. 98 th St., Lincoln,NE 68507 402-434-9102 info@binmaster.com www.binmaster.com INSTALLATION AND OPERATION

More information

LED Edge-Lit Flat Panels CCT Adjustable

LED Edge-Lit Flat Panels CCT Adjustable ASD LED Edge-Lit CCT Adjustable Panels have eliminated the need to settle on a single color temperature. These groundbreaking panels offer the ability to change color temperature (3K-5K) with the push

More information

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , , 4411H-English_Manuals 3/11/11 1:13 PM Page 1 Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos. 40-6526, 40-6529, 40-6544 Instruction Manual Congratulations on your choice of

More information

HD40H(X) Performance Series Camera. User Guide

HD40H(X) Performance Series Camera. User Guide HD31H(X) HD30H(X) HD40H(X) Performance Series Camera User Guide Document 1 2 HD40H(X)/HD30H(X)/HD31H(X) Camera User Guide Thank you for purchasing our product. If there are any questions, or requests,

More information

MBE Mounts and Adapters

MBE Mounts and Adapters MBE Mounts and Adapters MBE Series en Installation Guide MBE Mounts and Adapters Table of Contents en 3 Table of Contents 1 Important safety instructions 4 2 MBE Series Mounts and Adapters 6 2.1 Unpacking

More information

Serial No. OWNER S MANUAL. Installation & Operation

Serial No. OWNER S MANUAL. Installation & Operation Serial No. OWNER S MANUAL Installation & Operation Table of Contents Safety & Warranty Warnings 01 Parts List 02 GhostBed Electronics Quick Reference Guide... 03 Installation Guide 04 GhostBed Remote Control

More information

LED Edge-Lit Flat Panels CCT Adjustable

LED Edge-Lit Flat Panels CCT Adjustable ASD LED Edge-Lit CCT Adjustable Panels have eliminated the need to settle on a single color temperature. These groundbreaking panels offer the ability to change color temperature (3K-5K) with the push

More information

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE... 2 1.0 General Information... 3 1.1 System Components... 3 1.2 Specifications... 3 1.2.1 Torque Ranges... 3 1.2.2 Electrical Specifications...

More information

ITA100 MKII 100mW green DMX laser

ITA100 MKII 100mW green DMX laser ITA100 MKII 100mW green DMX laser User manual Safety instructions WARNING! Always keep this device away from moisture and rain! Hazardous electrical shocks may occur! WARNING! Only connect this device

More information

RS-422/485 to Fiber Industrial Converter

RS-422/485 to Fiber Industrial Converter RS-422/485 to Fiber Industrial Converter (IRF-612) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual 1676H-English 10/3/08 10:46 AM Page 1 Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No. 40-6602 Instruction Manual Congratulations on your choice of this Self-Leveling Cross Line Laser

More information

PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL

PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL HF80/15+DLP PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0 CONTENTS PAGE NO. NOTICE FOR SAFE OPERATION 2 INTRODUCTION... 3 NOTES TO USERS. 3 COMPONENTS.. 4 OPERATING CONDITIONS. 5 MAIN

More information

PHOS 20/40 downlight OWNER'S MANUAL

PHOS 20/40 downlight OWNER'S MANUAL PHOS 20/40 downlight OWNER'S MANUAL TABLE OF CONTENTS Safety Instructions...4 Electrical Safety... 4 Lamp Safety...4 Burns and Fire Safety... 5 Safety During Installation And Operation... 5 Technical Overview...

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

1. Safety instructions

1. Safety instructions AX-904 1. Safety instructions Failure to follow the instructions listed below may cause personal injury. Read and understand all instructions prior to any operation. Do not remove any label from the tool.

More information

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera INSTALLATION MANUAL ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera PACKAGE CONTENTS This package contains: One ST-BTWD650IR2812 camera with Black or White housing One extension tube

More information

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B Safety Tips Please read this manual carefully before installing the camera. Keep the camera away from violent vibration, physical stress, moisture, extreme

More information

Green Rotary Laser Level

Green Rotary Laser Level Owner s Manual Green Rotary Laser Level Model No. 320. XXXXX CAUTION: Before using this product, read this manual and follow all its Safety Rules and Operating Instructions. Safety Operation Maintenance

More information

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No 6274H-1_Manuals 9/26/12 10:44 AM Page 1 Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No. 40-6582 Instruction Manual Congratulations on your choice of this Electronic Self-Leveling

More information

ACCESSORIES FOR SAFETY DEVICES

ACCESSORIES FOR SAFETY DEVICES ACCESSORIES FOR SAFETY DEVICES - SE-DM: series: deviating mirrors - SE-LP: series: laser pointer - SE-S: series: floor stand - SE-SR2 series: safety relay - SE-SRT series: connection box INSTALLATION SE-DM

More information

Self-leveling Laser Marker (4V1HXL)

Self-leveling Laser Marker (4V1HXL) Self-leveling Laser Marker (4V1HXL) Congratulations on your choice of this Self-leveling Laser Marker. For the purpose of long-term use of this instrument, we suggest you to read this instruction manual

More information

CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL

CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL CONTENDER LED FRESNEL SPOT FOCUSING LIGHT USER MANUAL Contender INTRODUCTION THANK YOU FOR CHOOSING GENARAY The Genaray Contender is a compact and versatile light that s ideal for still and tabletop photography,

More information

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116 INSPECTION CAMERA MODEL NO: CIC2410 PART NO: 6470385 OPERATION & SAFETY INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Inspection Camera. Before attempting to use this product, please

More information

LED BEAM MOVING HEAD FL x3W User Manual

LED BEAM MOVING HEAD FL x3W User Manual LED BEAM MOVING HEAD FL-101 36x3W User Manual www.flash-butrym.pl Page 1 1. Preface 1.1 Packing list Product name moving head light Power -line User manual quantity 1 pcs 1 base 1 pcs 1.2 Unpacking instructions

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Complete Barrel Measuring and Inspection System. PS Series. User s manual

Complete Barrel Measuring and Inspection System. PS Series. User s manual Complete Barrel Measuring and Inspection System PS Series User s manual SAFETY PRECAUTIONS... 3 ELECTROMAGNETIC COMPATIBILITY... 3 LASER SAFETY... 3 GENERAL INFORMATION... 3 BASIC DATA AND PERFORMANCE

More information

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

SpectroLED STUDIO 800/1200 LED LIGHT USER MANUAL

SpectroLED STUDIO 800/1200 LED LIGHT USER MANUAL SpectroLED STUDIO 800/1200 LED LIGHT USER MANUAL SpectroLED INTRODUCTION THANK YOU FOR CHOOSING GENARAY The Genaray SpectroLED Studio Lights provide bright, continuous light with flicker-free dimming for

More information

Installation Manual. Alpha 4000 RGB Signs. Before you begin

Installation Manual. Alpha 4000 RGB Signs. Before you begin Installation Manual Alpha 4000 RGB Signs signs are indoor, two-line, full matrix LED displays. These signs can display both text and graphics and can be networked together. Before you begin 1. This manual

More information

Escort LED LIGHTS USER MANUAL

Escort LED LIGHTS USER MANUAL Escort LED LIGHTS USER MANUAL Escort INTRODUCTION THANK YOU FOR CHOOSING GENARAY The Escort series of LED light fixtures provides photographers and videographers with flicker-free continuous light. They

More information

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL SAFETY Read the following safety instructions before attempting to operate this product. Keep these instructions in a safe place or store in the carry case

More information

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement. www.lightware.co.za info@lightware.co.za The InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement. Able to measure to any solid surface, at any angle,

More information

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide USB 2.0 RG2324/2344 4-Port USB 2.0 Fiber Optic Extender System User Guide Thank you for purchasing the USB 2.0 RG2324 or RG2344. This document applies to the following part numbers: Please read this guide

More information

FlashMax P4 Ortho Manual

FlashMax P4 Ortho Manual FlashMax P4 Ortho Manual FlashMax P4 Ortho orthodontic light pen Page 3 Content WARNINGS 4 Technical description Technical specifications Environmental conditions for intended use 5 Preparing to use the

More information

Revo 120. User Manual

Revo 120. User Manual Revo 120 User Manual GENERAL INFORMATION Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The Revo 120 has been designed to perform

More information

High Precision Quad Output DC Power Supply

High Precision Quad Output DC Power Supply User's Guide High Precision Quad Output DC Power Supply Model 382270 Introduction Thank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use,

More information

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS... Thank you for your purchase of this product. Before operating the product, please read this instruction manual carefully to ensure proper use of the product. Please store this instruction manual in a safe

More information

Light as soft as a cloud.

Light as soft as a cloud. Light as soft as a cloud. As part of Luxli s Softi series, the LED Ring Light with Camera Mount provides soft, flattering light without harsh shadows. Control the intensity when illuminating your subject

More information

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

QUAD 1000 OWNERS MANUAL OPERATION GUIDE QUAD 1000 OWNERS MANUAL OPERATION GUIDE Built in Redmond Oregon USA COMPONENTS 4001-0000 Quad 1000 5 arc second zenith laser featuring electronic servo self-leveling with variable temperature compensation

More information

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2

More information

USER MANUAL MODEL: TDPB-2V1AD Dual square table box with HDMI, VGA, 3.5mm audio, and RJ45 inputs

USER MANUAL MODEL: TDPB-2V1AD Dual square table box with HDMI, VGA, 3.5mm audio, and RJ45 inputs USER MANUAL MODEL: TDPB-2V1AD Dual square table box with HDMI, VGA, 3.5mm audio, and RJ45 inputs Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Recycling Products

More information

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI DE EN FR Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI www.geo-fennel.de www.geo-fennel.com www.geo-fennel.fr Dear Customer, Thank you for your confidence in us, having purchased a geo-fennel

More information

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes. 1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations

More information

Xero A1/A1i. Owner s Manual

Xero A1/A1i. Owner s Manual Xero A1/A1i Owner s Manual 2018 Garmin Ltd. or its subsidiaries All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Garmin.

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

Specifications, Installation, and Operating Instructions

Specifications, Installation, and Operating Instructions Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.

More information

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS H-2304 Manual Stretch Wrap Machine 1-800-295-5510 uline.com SYSTEM SpecificationS IMPORTANT! Read this manual thoroughly and familiarize yourself with ALL controls and operating features. Keep this manual

More information

VRP5045W1045W 24 VAC Powered ZigBee Repeater For Schneider-Electric Wireless Networks Applications

VRP5045W1045W 24 VAC Powered ZigBee Repeater For Schneider-Electric Wireless Networks Applications 1 24 VAC Powered ZigBee For Wireless Networks Applications Product overview The wireless repeater has been specifically designed to be used within a wireless ZigBee network, for wireless controllers. The

More information

Robot Light V2. User Manual

Robot Light V2. User Manual Robot Light V2 User Manual 2 Please read over this manual before operating the light. Introduction Unpacking: Thank you for purchasing the Robot Light V2. Every Robot Light V2 has been thoroughly tested

More information

FengMi Wemax One Laser Projection TV

FengMi Wemax One Laser Projection TV FengMi Wemax One Laser Projection TV User`s Manual About electrical ground Transportation Use this device only with a compulsory grounding condition. It is recommended that you use the original packaging

More information

3D OBJECTS RGB LASER. Order ref: UK User Manual

3D OBJECTS RGB LASER. Order ref: UK User Manual TECHNICAL SPECIFICATION Voltage : 230Vac, 50/60Hz Blue : 300mW 455nm Fuse : 2A Slow blow DMX Channels : 20 Dimensions : 220 x 176 x 99mm Laser Class : 3B Red Laser: 100mW 638nm Power Consumption : 45W

More information

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use Ostar Eye K6 Beam and Kaleido Effects User manual Please read the instructions carefully before use TABLE OF CONTENTS 1. Safety Instructions... 2 2. Technical Specifications... 4 3. How To Control The

More information

Ground Master Monitor Installation, Operation and Maintenance

Ground Master Monitor Installation, Operation and Maintenance USER GUIDE TB-9078 Ground Master Monitor Installation, Operation and Maintenance Made in the United States of America The Ground Master Monitor and its accessories are available as the following item numbers:

More information

Infrared Thermometer User Manual

Infrared Thermometer User Manual Infrared Thermometer User Manual Contents 1. Introduction... 2 2. Features... 2 3. Application... 2 4. Safety...3 5. Field of View...4 6. Specifications... 5 7. Meter Description...6 8. LCD Display Description...6

More information

Serial No. OWNER S MANUAL. Installation & Operation

Serial No. OWNER S MANUAL. Installation & Operation Serial No. OWNER S MANUAL Installation & Operation Table of Contents Safety & Warranty Warnings 01 Parts List 02 BT1000 Electronics Quick Reference Guide 03 BT2000 Electronics Quick Reference Guide 04

More information

Omni Verifier User s Manual

Omni Verifier User s Manual Omni Verifier User s Manual 363325 Rev. 01 Page 1 of 9 Packing List (see Figure 1) 1. Omni Verifier 2. Docking Station 3. Universal Power Supply 4. Mounting Hardware (2 screws and 2 wall anchors shown

More information

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Version 1.06 Metertech Inc. provides this publication as is without warranty of any kind, either express or implied, including, but

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

DUAL LASER PACK & CONTROLLER USERS MANUAL

DUAL LASER PACK & CONTROLLER USERS MANUAL DUAL LASER PACK & CONTROLLER USERS MANUAL www.venuelightingeffects.com 89.0 Venue PP laser Instr.indd 5//08 6:09:5 PM SAFETY INFORMATION Never operate this unit if it has a damaged cord or plug. Keep the

More information

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI DEUTSCH NEDERLANDS NORSK ČEŠTINA ENGLISH FRANÇAIS ITALANIO Hersteller Wörlein GmbH Tel.: +49 9103/71670 Gewerbestrasse 12 Fax.: +49 9103/716712 D 90556 Cadolzburg Email. info@woerlein.com GERMANY Web:

More information

Overview 2. Technical data 3. Instrument Set-up 4. Operations 7. Message Codes 9. Accuracy Check 10. Care 13. Warranty 14. Safety instructions 15

Overview 2. Technical data 3. Instrument Set-up 4. Operations 7. Message Codes 9. Accuracy Check 10. Care 13. Warranty 14. Safety instructions 15 Leica Lino L4P1 Overview 2 Technical data 3 Instrument Set-up 4 Operations 7 Message Codes 9 Accuracy Check 10 Care 13 Warranty 14 Safety instructions 15 Leica Lino L4P1 1 Overview Ov e rv ie w The Leica

More information

Use the ML830 Smart laser System only as directed.

Use the ML830 Smart laser System only as directed. I. INTRODUCTION This manual provides operators with step-by-step instructions for use, precautions, warnings, care. and maintenance procedures. Please read this manual thoroughly and familiarize yourself

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

INTRODUCTION CT87E FEATURES AND CONTROLS

INTRODUCTION CT87E FEATURES AND CONTROLS INTRODUCTION The CT87E is a precision instrument used to monitor and record the presence or absence of voltage, light, or sound level such as what would be produced by an operating electric motor or compressor.

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

1500V - Vacuum Rated

1500V - Vacuum Rated Preliminary 8/20/2008 Mercury Digital Output Encoder System Installation Manual and Reference Guide 1500V - Vacuum Rated Customer Controller Vacuum Wall Manual No. IM-M1500V Rev S7 Introduction MicroE

More information

FCC Regulatory Information

FCC Regulatory Information DVW32C Advanced Wireless Voice Gateway - Safety and Installation Product Insert Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the

More information

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Limited Warranty All NOYES test equipment products

More information

PHOS mini OPERATING INSTRUCTIONS

PHOS mini OPERATING INSTRUCTIONS PHOS mini OPERATING INSTRUCTIONS TABLE OF CONTENTS Safety Instructions...4 Electrical Safety... 4 Burns and Fire Safety... 5 Lamp Safety...5 Safety during installation and operation... 6 Technical Overview

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

Weatherproof IR Color Day/Night Cameras

Weatherproof IR Color Day/Night Cameras Weatherproof IR Color Day/Night Cameras Products: CFC6042IR, CFC6042IR2, CFC6042IR3, CFC6043IR, CFC6043IR2, CFC6043IR3 Please read this manual before installing and using this camera and always follow

More information

Vertiv Local Rack Access 18.5" LED LCD Console

Vertiv Local Rack Access 18.5 LED LCD Console Vertiv Local Rack Access 18.5" LED LCD Console With Integrated Keyboard, Touchpad and Dual USB 2.0 Ports Installer/User Guide Technical Support Site If you encounter any installation or operational issues

More information

Aligning Parallelism of Rolls Has Never Been Faster. L-732 Precision Dual-Scan Roll Alignment System

Aligning Parallelism of Rolls Has Never Been Faster. L-732 Precision Dual-Scan Roll Alignment System Aligning Parallelism of Rolls Has Never Been Faster L-732 Precision Dual-Scan Roll Alignment System Why the L-732 Roll Alignment System is Better Roll parallelism accuracy of.00018 in/ft (0.015 mm/m) Up

More information

SAFETY WARNINGS AND GUIDELINES

SAFETY WARNINGS AND GUIDELINES 1 SAFETY WARNINGS AND GUIDELINES Please read this entire manual before using this device, paying extra attention to these safety warnings and guidelines. Please keep this manual in a safe place for future

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS CONTENTS Important safety instructions... Specified Conditions of Use... Error Code Table... Overview... Change batteries...4 Corner Pin...4 Belt Clip...4 Function Switch, Pythagoras, Measuring Reference...5

More information

Handheld Video Magnifier

Handheld Video Magnifier Zoomax TM Snow Handheld Video Magnifier V1.1 1 Contents Description...3 Accessories...3 Compositions:...4 Operation...5 Battery installation...5 Charging the battery...6 Install short strap...6 Operation

More information

Motorized Curtain Tracks Progress 50 Motor Set

Motorized Curtain Tracks Progress 50 Motor Set Troubleshooting Before you decide that the trouble is a malfunction, perform the following check. Condition Not operating Unstable operation Moves adversely and in opposite direction Operation speed is

More information