IL 800D LED SFL/TIL System
|
|
- Samantha Cooper
- 6 years ago
- Views:
Transcription
1 IL 800D LED SFL/TIL System Approach Sequential Flash (SFL) - Threshold Identification (TIL) System Compliance with Standards ICAO IEC TS FAA Annex 14, Vol. I, Aerodrome Design Manual Part-6, Frangibility EB 67D STANAG 3316 Uses LED light used for approach sequential flash and threshold identification for CAT I, II and III operations. Features Dynamic system configuration by parameter setting Single light monitoring even in standby mode Dynamic operation mode in 3 brightness steps (100%, 10% and 3%) Flash frequency switchable between 2 or 1 Hz Optional lights with high intensity Optional lights with anti-moisture heater Service local control at control unit possible Optional comfort control panel for service local control lucdmc Service Software Over voltage and lighting current protection of power and data lines 1 parallel remote control interface 2 CAN-bus remote control interface (redundant) 2 serial remote control interface (redundant) with RS-485 MODBUS/RTU Optional remote control interface with Ethernet MODBUS/TCP or PROFIBUS DP Light power supply with SELV System Design The approach sequential flash light system consists of a control unit, main chain (SFL - light 1..30), threshold identification (TIL - light ) and power distribution units (1..32). 32 Kableplan Cable Layout m Slave n V Control Unit Load Center 50/60 Hz Remote Control Steuerschrank MCU8000D-SFL COM SYS-800D 1
2 32 Position Runway 31 optional 300 m 900 m 30 m The SFL800D system enables following static (installation) or dynamic (configuration settings) system configurations: Full main chain with TIL (light 1..32) Reduced main chain with TIL (light ) TIL without main chain (light ) Main chain without TIL light (1..30) could be realized as special solution Elevated, single inset or double inset lights available for installation. Principle terminal diagram of the approach flash lighting system SYS-800D 2
3 Technical Data Power supply Power consumption Fuse Communication interface remote control Communication interface comfort local control Communication interface service computer Communication interface flash lights Control Unit Power circuit: 400 VAC, 3 Ph., 50/60 Hz 1,4 kva, asymmetric load, main load at L1/L2 Internal fuse automat 10A fuse characteristic K 2 CAN-BUS 2 MODBUS/RTU 8 24VDC Input parallel interface 5 24VDC Output parallel interface I2C USB 2-wire power line Environmental temperature -25 to +45 C Relative humidity, not condensed 10 to 90% International Protection class IP 43 Altitude over NN (operation) Housing Dimensions Weight -100 to m Metal housing wall mounted mm (B H D) 22 kg Power supply Max. Power consumption Communication interface control unit Flash Light 36 VAC, 50/60 Hz (SELV) EL = 20 VA IL = 20 VA 2-wire power line (SELV) Environmental temperature -25 to +85 C Relative humidity, not condensed 10 to 100% International Protection class Altitude over NN (operation) Dimension (Packaging) (W H D) Weight LED power (SFL configuration settings general) Standard (EL dimmed) High LED power (SFL configuration settings general) Standard (EL dimmed) High Nominative life time Color temperature, typical IP to +2'500 m EL = mm IL = mm EL = 7.5 kg IL = 6.9 kg EL 12'.500 cd eff. 21' 000 cd eff. IL 7' 500 cd eff. 7' 500 cd eff. * > h Cold Notes * For harmonization of the visual impression the use of double inset flash lights is recommended. Power Distribution Unit Power circuit Primary circuit: 400 VAC, 50/60 Hz Primary circuit: 36 VAC (SELV) Data communication Environmental temperature -40 to +55 C Relative humidity, not condensed 10 to 100% International Protection class Altitude over NN (operation) Housing Dimension Wight Primary circuit: Powerline Primary circuit: Powerline (SELV) IP 68, 1m immersion depth -100 to m Full potted PU housing mm (D L) without cable 6,5 kg SYS-800D 3
4 Dimension Elevated Flash Light*: Standard *Base plate and frangible pedestal are not shown and are not part of the flash light. These articles can be ordered separately from accessory. Dimension Inset Flash Light*: *12 shallow base and deep base can with transformer shown for complete view only but not part of the flash light. These articles can be ordered separately from accessory. Installation Refer to manual SYS-800D 4
5 APPROACH LIGHTING Isocandela Diagram Elevated Flash Light Values according to Ie = 5 * Idt (Formula (4) ICAO Aerodrome Designe Manual Part 4 Chapter ) Isocandela Diagram Inset Flash Light Values present measured average impulse intensity. Calculated effective intensity* is cd. * Ie = 5 * Idt (Formula (4) ICAO Aerodrome Design Manual Part 4 Chapter ) SYS-800D 5
6 Order Codes Part Number * Order Code Description MCU800D-SFL/TIL Control unit OLP800D-SFL/TIL Overvoltage and lightning current protection unit PDU800D-SFL/TIL Power distribution unit lucdmc Service Software EL 817D-SFL/TIL-EFC-w Elevated flash light with FAA style 1/8 connector, delivery content (1) EL 817D-SFL/TIL-w Elevated flash light Phoenix Contact connector, delivery content (2) IL 868D-SFL/TIL-w Inset flash light with Phoenix Contact connector, delivery content (3) Set 2x IL 868D-SFL/TIL-w Set with double inset flash light with Phoenix Contact connector, delivery content (4) IL 868D-SFL/TIL-EFC-w Inset flash light with FAA style 1/7 connector, delivery content (5) Set 2x IL 868D-SFL/TIL-EFC-w Set with double inset flash light with FAA style 1/7 connector, delivery content (6) MF1932 Base plate 2 /NPS STF-N30 Frangible pedestal Shallow Base standard Standard shallow base Shallow Base with O-ring Shallow base waterproof with O-ring PE Kit For potential equalization of double inset light, 1 per shallow base 2 PSD800D-SFL Dongle for parameterization of inset lights Notes * Supply of required electric and installation parts (joint, T-joint, cabling) is not part of ERNI AGL AG delivery but responsibility of the installer. For more details refer to manual. 1 Refer to manual. 300 Ohm termination resistor of data lines delivered with MCU. 2 Delivery without cable. Please mount before applying the shallow base. Delivery Content Flash Lights (1) 4-Pin FAA Style mm (3) 5-Pin Phoenix Contact mm (5) 5-Pin FAA Style 1 5-Pin FAA Style mm 4-Pin FAA Style 1 (2) (4) (6) 5-Pin Phoenix Contact mm (1 Pin not used) Product specifications may be subject to change, and specifications listed here are not binding. Confirm current specifications at time of order SYS-800D 6
Clearance Bar - TCB. IL 880D LED Inset Light 8. IL 882D Bi-directional / Non switchable. IL 883D Bi-directional / Directional switchable
IL 880D LED Inset Light 8 IL 882D Bi-directional / Non switchable IL 883D Bi-directional / Directional switchable IL 887D Unidirectional Colors yellow - red Application Inset LED light used for intermediate
More informationFCU, FFL, UEL APPROACH LIGHTING. Approach and/or RTILS Capacitor Discharge Flashing System. Compliance with standards. Uses. General description
Approach and/or RTILS Capacitor Discharge Flashing System Compliance with standards ICAO: FAA: Annex 14, Vol. I, para. 5.3 (current edition) L-849 A/C/E as per AC-150/5345-51 E-2159, E-2325, E-2628, E-2689
More informationDIAM to 15 kva
www.ocem.com DIAM4200 1 to 15 kva IGBT controlled Sinusoidal Single-Phase Constant Current Regulator COMPLIANCES ICAO: Annex 14 - Volume I, Aerodrome Design Manual Part 5 IEC: 61822 FAA: L-828/L-829 AC150/5345-10
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationIB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B
INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area Data Sheet 5764B 09/2000 # % $ This data sheet is only valid in association with the INTERBUS Inline System Manual IB IL SYS
More informationETT 312 Build-In Touch Terminal
ETT 312 Build-In Touch Terminal Date of creation: 01.02.2016 Version date: 23.01.2017 Article number: 01-230-312-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
More information8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW
1 General information Connections for supplying external 24 V devices Extensive protective measures 2 Order data Model number Short description Figure Wall mounting ACOPOSmulti auxiliary supply module,
More informationSmart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway
Smart Energy & Power Quality Solutions ProData datalogger Datalogger and Gateway Smart and compact: Our most universal datalogger ever saves power costs Ethernet connection Modbus-Ethernet-Gateway 32 MB
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationICAO Low-intensity Type A Obstruction Light (10cd) with infrared ICAO Low-intensity Type B Obstruction Light (32cd) with infrared
DATASHEET 05 Feb 2016 Key features - Night Vision Goggles compatible - Based on LED-technology - Extremely reliable with long lifetime - Suitable for off-shore use - Very low power consumption - Wide input
More informationSmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out
SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)
More informationLow-Intensity Infrared SAL
Low-intensity infrared SAL Page 1 6 Optical characteristics 10cd fixed or flashing 32cd fixed or flashing Colour aviation RED Horizontal beam 360 Vertical beam +6 +10 Low-Intensity 10 and 32cd with Stand-alone
More information16-Channel Input Digital Input Termination Card
TDI16EIA 16-Channel Input Digital Input Termination Card (TDI16EIA) Issue 3 October 2005 Introduction Purpose The TDI16EIA 16-channel digital input termination card acts as an interface between the digital
More informationSmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output
SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,
More informationInstallation Manual for D244X Series 24-volt Power Supplies
Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power
More informationACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction
ACOPOSinverter P74 User's Manual Version: 2.20 (August 2016) Model no.: MAACPIP74-ENG Original instruction All information contained in this manual is current as of its creation/publication. We reserve
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationString Inverter (SUN2000-8/12KTL)
String Inverter (SUN2000-8/12KTL) 2 MPPTs for versatile adaptions to different module types or quantities built up with different alignments 4 strings intelligent monitoring and 80% time saving for fault
More informationICAO Low-intensity Type A (10cd) + Infrared 850nm ICAO Low-intensity Type B (32cd) + Infrared 850nm
DATASHEET ICAO Low-intensity Type A (10cd) + Infrared 850nm 05 Feb 2016 Low-Intensity 10cd and 32cd with Infrared 850nm Stand-alone LED Aviation Obstruction Lights Low-intensity red aviation warning light
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationTechnical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B
Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories
More information16-Channel Digital Input Termination Card 24Vdc
TDI16BIA 16-Channel Digital Input Termination Card 24Vdc (TDI16BIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16BIA16-channel digital input termination card acts as an interface between the digital
More informationRT4B-110V/12A RECTIFIER
The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs
More informationRT4F-120V/20A-WAC RECTIFIER
The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationASO. Automatic Switch-Over. GOLLAND Sp. z o.o.
ASO Automatic Switch-Over Compliance Standards ICAO Aerodrome design manual, part 5 IEC (61820, 61821, 61822) Applications The ASO Automatic Switch Over has been designed to detect any failure or breakdown
More informationWP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement
All control functions are integrated Integrated realtime grid measurement Gigabit Ethernet, Serial RS232/RS422/RS485 Direct integration with safety system Advanced data collection and storage Mechanically
More information16-Channel Digital Input Termination Card 24Vdc
TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital
More informationRT7-48V/6kW Specification
The RT7-48V/6kW is a 3 phase, active power factor corrected, switched mode rectifier (SMR) module designed to provide up to 6kW of output power (100A nominal) into a 48V nominal system. This rectifier
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationSD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A
Characteristics motion control stepper motor drive - SD328 -
More informationDIRIS Digiware D and C Communication and control power interfaces
Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data
More informationRT4F-48V/50A-WAC RECTIFIER
The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been
More informationTSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC
Characteristics 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC Main Range of product Product or component type I/O modularity Mar 05, 2018 Modicon Premium Automation platform
More informationAirmux-400, Airmux-5000 Optional Accessories
Data Sheet, Optional Accessories Airmux-IDU-H Airmux-HSSU Airmux-OPOE/DC Aimux-MHS-kit Airmux-PoE/GbE Airmux-Lightning-Protection Aimux-PoE/GBE/DC Aimux-PoE/DC Airmux-GSU Airmux-FE-Repeater , Optional
More informationModular PDU Smart metering for your IT
Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationOTB1C0DM9LP I/O distributed module OTB - CANopen bus m
Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More informationSTBEHC3020KC counter kit STB - 1 CH Hz - 2 I
Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency
More informationIBS IL 24 BK RB-T-2MBD
IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the
More informationS SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationTime Counters mini "h", DC Version
Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable
More informationConverter Box Data Sheet
Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to
More informationFieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway
Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety
More informationRT12-240V/2.4kW Rectifier Specification
The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between
More informationThe 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.
The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant
More informationICPDAS FSM-510G Series Ethernet Management Switch Quick Start
ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed
More informationPCM SLK- Series Inverter Specification
PCM SLK- Series Inverter Specification Page 1 of 7 General Specification Introduction Environment The inverters are designed to be outdoor types. Models In field applications, the power demands from 1.5kW
More informationTemposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm
R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Measuring length 5-7600 mm Advanced Communication... offers Multi-Position Measurement Rugged Industrial Sensor
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationTemposonics. R-Series Profibus. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm
Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH Stroke length 25 7600 mm Advanced Communication offers Multi-Position Measurement Rugged industrial sensor Linear and absolute
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationdigiclip Data sheet DF31DP Special features B en
digiclip DF31DP Data sheet Special features Digital amplifier for industrial automation tasks and production process monitoring 600 Hz CF measurement technology with TEDS sensor detection for SG full bridges
More informationThe TRSUN is the complete solution for the remote monitoring of photovoltaic plants.
The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system
More informationCIR-e 3. Portable power analyzer. Portable power analyzer M8-27. Features. Description. Application
CIR-e 3 Portable power analyzer Features Measure in 2 quadrants the main parameters for single-phase and three-phase electrical networks with 3 and 4 wires. True root mean square measure Energy meter.
More informationInterface converter for VAV compact controllers
s 5 852 OpenAir (Optional) Interface converter for VAV compact controllers AST11 The interface converter is used to convert the PPS2 into an RS-232 or USB interface signal. It is suited for use with the
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX
User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationStatus display unit with P-bus connection
8 917 DESIO TM I/O modules with P-bus connection PHM1.36TL for connections to automation stations with P-bus for status indication of up to 24 messages for remote control of up to 12 operating points in
More informationATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)
Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component
More informationVL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features
Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationSwitching Power Supply
Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input
More informationXPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Sep 11, 2018 Preventa Safety automation Kit configurable
More informationOutput Voltage* (nom.)(adjustable)
Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 59,5mm Suitable for mounting in domestic installation panels Low output ripples and spikes Fully compliance to ECO-Standard
More informationAC-DC Converter REC K10
Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationWP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments
CPU module for small and medium sized wind turbines Safe operation in harsh environments Maintenance free - no fans and no batteries that need replacement Advanced event based data logging and storage
More informationPower Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41
6. 6.1 Order Data Model Number 4P3040.00-490 1) 0AC201.9 0MC111.9 0MC211.9 4A0034.00-000 4EX101.00 7TB712.9 7TB712.91 7TB712:90-02 7TB712:91-02 Short Description, 5.7 inch QVGA black/white LC display,
More informationxin 4, xio 4x4 and xout 4
Data Sheets xin 4, xio 4x4 and xout 4 T +1.425.778.7728 F +1.425.778.7727 www.symetrix.co xin 4 xin 4 Audio input (A/D) expander for SymNet systems that capitalizes on the surplus DSP of a Dante-enabled
More information6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots
Product Overview 6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots Description Unmanaged Industrial PoE Ethernet switch with P.S.E. function. The MS655203PX switch supports Power-over-
More informationDouble-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional
Double measurement of free chlorine and ph -optionally with additional ORP measurement Easy and safe operation by plain text menu guidance Log book function Graphical trend display of the last 3 h applications
More informationOTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m
Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage
More informationTM3DI16 module TM3-16 inputs
Characteristics module TM3-16 inputs Main Range of product Product or component type Range compatibility Jun 30, 2018 Modicon TM3 Discrete input module Modicon M241 Modicon M251 Modicon M221 Discrete input
More informationMCR 3. POWER EQUIPMENT MCR 3 I Constant Current Regulator. Microprocessor Controlled Constant Current Regulator. Compliance with Standards.
MCR 3 Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: AC 150/5345-10 (current edition), L-828, L-829. ICAO: Aerodrome Design Manual Part 5, para. 3.2 (current edition)
More informationTM3AI4 module TM3-4 analog inputs
Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
More informationVARAN Splitter Module VSV 041
VARAN SPLITTER MODULE VSV 041 VARAN Splitter Module VSV 041 With its 4 VARAN Out ports, the VARAN VSV 041 splitter module allows a VARAN bus system to be configured in a tree structure. At the Ethernet
More informationUMG 96RM. UMG 96RM Universal measurement instrument. Areas of application
UMG 96RM UMG 96RM Universal measurement instrument The UMG 96RM is a very compact and powerful universal measurement device designed for use in low and medium voltage distribution systems. In addition
More informationF150 Vision Controller with integrated PROFIBUS-DP unit. 9-pin female sub-d connector (RS-485 ProfiBus) Bus termination
PNSPO F150 Vision Controller PROFIBUS-DP Unit F150-C15E-3-PRT F150 Vision Controller with integrated PROFIBUS-DP unit Main features PROFIBUS setting fully integrated into F150 user menu Auto-detection
More informationPowermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control
Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac
More informationOperating and mounting instructions
General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore
More informationTruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationEvolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series
www.eaton.com _ Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series 34008235EN/AC - Page 2 Introduction Thank you for selecting an EATON
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Product datasheet Characteristics OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication
More information5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line
Product Overview 5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line Description The new Gigabit Ethernet industrial switch offers the full Gigabit performance on all ports. This offers, beside
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationiopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission
iopac 8020 Series Rugged modular RTU controllers Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain
More informationOTB1C0DM9LP I/O distributed module OTB - CANopen bus m
Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Complementary Topology Main Range of product Product or component type Integrated connection type Bus type Number of slave 0...63 Bus
More informationATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)
Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product
More informationInstallation Unit Primary Switched Power Supply 1500 W EXW /OP1 adjustable V/I
Ordering Information Type Output Input Voltage Housing Dimensions see drawing Article No.* EXW 6.50 / OP V = 4 V 6 V* 40 V I = 8 A 50 A* 00 40 Vac 70x50x08 mm 750-4-00 * Housing chrome plated on the inside
More information