1 WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C 1 Description PHOENIX CONTACT Features The RAD-WHG/WLAN-XD is a WirelessHART gateway with integrated b/g WLAN transceiver. It can connect up to 250 WirelessHART field devices and convert the HART data to Modbus TCP for easy integration into almost any asset management system. The connection can be made via the onboard Ethernet port or the WLAN client transceiver, and the HART to Modbus TCP mapping is automatic. The RAD-WHG/WLAN-XD is configurable via an embedded web server. System diagnostics are also available through the web server or locally, an RF Link relay indicates if the WLAN connection is present, and the strength of the WLAN signal can be measured at the RSSI test point as an analog voltage. The WirelessHART data is protected with 128-bit AES encryption and the WLAN data utilizes WEP, WPA, or WPA2 /802.11i for encryption. WirelessHART gateway supports up to 250 WirelessHART devices Integrated b/g with i security Converts HART to Modbus TCP Simple programming via embedded web server 128-bit AES encryption WEP, WPA or WPA2/802.11i encryption Make sure you always use the latest documentation. It can be downloaded at This data sheet is valid for all products listed on the following page:

2 3 Ordering Data Products Description Type Order No. Pcs./Pkt. Gateway, WirelessHART with integrated b/g and Modbus TCP conversion RAD-WHG/WLAN-XD Accessories Description Type Order No. Pcs./Pkt. Omnidirectional antenna, IP55, 6 dbi gain, linear vertical, N (female) connection RAD-ISM-2400-ANT-OMNI Omnidirectional antenna with vandalism protection, gain 3 dbi, IP55, RAD-ISM-2400-ANT-VAN-3-0-SMA m cable length, SMA (male) connection Parabolic antenna, IP65, 19 dbi gain, linear vertical, N (female) connection RAD-ISM-2400-ANT-PAR Antenna cable, EF 393, with 3 m cable, N (male) connection RAD-CAB-EF393-3M Surge protective device, Lambda/4, N (female) connection CN-LAMBDA/4-5.9-BB Adapter, RSMA female to SMA female RAD-ADP-RSMA/F-SMA/F Technical Data General Data Material Polyamide PA, non-reinforced Degree of protection IP20 Mounting NS 35 Mounting position Any Dimensions (W x H x D) 45 x 99 x mm Weight 215 g Operating temperature C Storage temperature C Relative humidity, non-condensing 10 90% Electrical Data Nominal voltage Supply voltage Power consumption, typical Power consumption, maximum Conductor size, solid, stranded, AWG 24 V DC 9 30 V DC 4.1 W 7.2 W mm², m², AWG WirelessHART Radio Interface Frequency range GHz Channel separation 5 MHz Number of channels 15 Transmission power 0 10 dbm Receiver sensitivity -90 dbm Antenna connection RP-SMA female LEDs Status 2720_en_C PHOENIX CONTACT 2

3 WLAN (802.11) Radio Interface Frequency range GHz Channel separation 5 MHz Number of channels 13 Transmission power b +17 dbm g +17 dbm (6-36 Mbps) +15 dbm (48-54 Mbps) Receiver sensitivity b 1 Mbps -94 dbm 11 Mbps -87 dbm g 6 Mbps -89 dbm 9 Mbps -88 dbm 12 Mbps -86 dbm 18 Mbps -85 dbm 24 Mbps -88 dbm 36 Mbps -78 dbm 48 Mbps -74 dbm 54 Mbps -72 dbm Antenna connection RP-SMA female (2x) Ethernet Interface Port connection Transmission rate HART Interface Connection Signal Indicators (green) (green) (green) DATA (yellow) (red) RF (green) RF DATA (yellow) RF Link (floating N/O contact) Maximum switching voltage Maximum switching current RSSI test voltage range RJ45 female (autocross) Mbps (auto negotiate) Test loops HART FSK Flashing - device initializing On - power/device active On - WirelessHART device(s) connected Off - No WirelessHART devices found On - LAN connected Flashing - Tx/Rx on LAN connection Off - no errors On - internal error On - WLAN connected Flashing - No WLAN link Flashing - Tx/Rx on WLAN connection 30 V DC 150 ma V DC Approval/Conformance Conformance Conformance with R&TTE directive 99/5/EC Conformance with LVD directive 2006/95/EC Conformance with EMC directive 2004/108/EC Conformance with ATEX directive 94/9/EC Conformance with IEC , , Canada: Class I, Division 2 Groups A,B,C,D Ex na IIC T5 USA: Class I, Zone 2, Group IIC; AEx na IIC T5 ATEX Ex na IIC T4 Gc; Sira 10ATEX4252X IECEx Ex na IIC T4; IECEx CSA X c 2720_en_C PHOENIX CONTACT 3

4 RAD-WHG/WLAN-XD 5 Application Examples Ethernet Host B(-) A(+) B(-) A(+) Power RF Link Transmit Transmit FLBL R1 ANT 1 ATUS ANT 2 RS-485 RX RS-485 TX Power RF Link RS-232 RX RS-232 TX RF RF DATA WAN SPEED WAN RSSI RAD XD/HP-BUS WLAN Access Point Power RF Link Figure 1 WirelessHART network with backhaul connection Ethernet Host Power RF Link Figure 2 WirelessHART network connected directly to Ethernet network 2720_en_C PHOENIX CONTACT 4

5 6 Installation Notes Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as general technical regulations, must be observed. Observe the technical data in this data sheet and subsequent documentation ( In order to protect the modules against electrostatic discharge when working on control cabinets, the operating personnel must remove electrostatic discharge before opening control boxes or control cabinets and before touching the modules. The modules are snapped onto a DIN rail within a control cabinet or control box. The control cabinet/box must meet the requirements of EN/IEC :2001 in terms of fire protection shielding. The device must not be opened or modified. Do not repair the device yourself; replace it with an equivalent device. Repairs may only be carried out by Phoenix Contact. The manufacturer is not liable for damage resulting from violation. The IP20 degree of protection (EN/IEC 60529) of the device is intended for use in a clean and dry environment. The device must not be subject to any strain or load, which exceeds the limits described. In the electrical system of the building, a 2-pos. disconnecting device must be provided to isolate the equipment from the supply circuit. The device is designed for installation in zone 2 potentially explosive areas. WARNING: Correct usage in potentially explosive areas. The device is not designed for use in atmospheres with a danger of dust explosions. Observe the specified conditions for use in potentially explosive areas. Install the device in housing (control or distributor box) that meets the requirements of EN/IEC and has at least IP54 protection (EN/IEC 60529). Only passive antennas may be operated on the devices. When installing and connecting the supply and signal circuits, observe the requirements of EN/IEC Only devices which are designed for operation in Ex zone 2 and are suitable for the conditions at the installation location may be connected to the circuits in zone _en_C PHOENIX CONTACT GmbH & Co. KG Blomberg Germany Phone: +49-(0) PHOENIX CONTACT P.O. Box 4100 Harrisburg PA USA Phone:

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

PHOENIX CONTACT - 04/2008

PHOENIX CONTACT - 04/2008 Serial Bluetooth adapter for a wireless connection of a serial interface to a Bluetooth access point AUTOMATION Data Sheet 7660_en_01 PHOENIX CONTACT - 04/2008 1 Description The FL BLUETOOTH Serial Port

More information

MINI MCR-SL-MUX-V8-FLK 16

MINI MCR-SL-MUX-V8-FLK 16 Multiplexer Data sheet 445_en_4 PHOENIX CONTACT 22-5-2 Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6,

More information

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description I/O extension module, analog current inputs Data sheet 1069_en_00 SATEL 015-10-7 1 Description The I/O extension module can be used in conjunction with SATEL-LP wireless modules. In a station structure,

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs INTERFACE Data sheet 104832_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DAIO6-IFS I/O extension module can be

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

3225_en_D Description

3225_en_D Description 3225_en_D 2014-01-21 1 Description 2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 4 5 Safety regulations and installation notes... 6 5.1 Installation

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments AUTOMATION Data Sheet 2806_en_C 1 Description PHOENIX CONTACT 2011-06-28 2 Features and Benefits The FL SWITCH SFN(T) 16(15)(14)TX

More information

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description

RAD-PT100-4-IFS. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description R-PT100-4- I/O extension module, 4 temperature inputs (Pt 100) ata sheet 105366_en_00 PHOENIX CONTCT 2013-12-06 1 escription The R-PT100-4- I/O extension module can be used in conjunction with Radioline

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET WirelessHART components Gateway and accessories 2 Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description 3-way signal conditioner Data sheet 106012_en_02 PHOENIX CONTACT 2016-02-19 1 Description The standard signal 3-way signal conditioner with pluggable connection technology is used to electrically isolate,

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide RAD-80211-XD and RAD-80211-XD-WM 802.11a/b/g Transceiver with Serial Link Quick Start Guide 1 This Quick Start Guide is intended to provide adequate information necessary to get a functional system operating.

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description (-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase

More information

PHOENIX CONTACT - 02/2008

PHOENIX CONTACT - 02/2008 Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

Valueline Industrial PC

Valueline Industrial PC A configurable industrial computer platform AUTOMATION Data Sheet 2643_en_F 1 Description PHOENIX CONTACT 2011-07-15 2 Features The Valueline Industrial PC (VL IPC) product line is a configurable industrial

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT - 10/2009 Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used

More information

PSI-GPRS/GSM-MODEM/RS232- QB

PSI-GPRS/GSM-MODEM/RS232- QB PSI-GPRS/GSM-MODEM/RS232- QB Serial mobile communication modem for GSM and GPRS Data sheet 103144_en_03 PHOENIX CONTACT 2015-05-12 1 Description The DIN-rail-mountable PSI-GPRS/GSM-MODEM/RS232- QB mobile

More information

Technical Information WirelessHART Fieldgate SWG70

Technical Information WirelessHART Fieldgate SWG70 TI00027S/04/EN/14.14 71247524 Products Solutions Services Technical Information WirelessHART Fieldgate SWG70 Intelligent WirelessHART gateway with Ethernet and RS-485 interfaces Application Fieldgate SWG70

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

MACX MCR-SL-(2)I-2)I-ILP(-SP)

MACX MCR-SL-(2)I-2)I-ILP(-SP) Passive isolator, one and two channel Data sheet 106893_en_01 PHOENIX CONTACT 2015-12-07 1 Description The single- or dual-channel input loop powered 2-way isolator with plug-in connection technology is

More information

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PSR-PS21. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description Repeater for RS-485 2-wire bus systems Data sheet 100273_en_06 PHOENIX CONTACT 2016-09-09 1 Description The PSM-ME-RS485/RS485-P RS-485 repeater was developed for the high requirements of fieldbus systems.

More information

QUINT-PS-3x AC/24DC/10

QUINT-PS-3x AC/24DC/10 3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.

More information

SATEL-LP MHz wireless transceiver (transmitter and receiver) with RS-232 and RS-485 interface, can be extended with I/O extension modules

SATEL-LP MHz wireless transceiver (transmitter and receiver) with RS-232 and RS-485 interface, can be extended with I/O extension modules 868 MHz wireless transceiver (transmitter and receiver) with RS-232 and RS-485 interface, can be extended with I/O extension modules Data sheet 106917_en_00 SATEL 2015-10-26 1 Description In addition to

More information

MACX MCR-EX-SL-NAM-R(-SP)

MACX MCR-EX-SL-NAM-R(-SP) Intrinsically safe NAMUR isolating amplifier with relay output INTERFACE Data sheet 03463_en_00 PHOENIX CONTACT - 08/2008 Description The NAMUR MACX MCR-EX-SL-NAM-R(-SP) isolating amplifier has been designed

More information

SATEL-LP product family

SATEL-LP product family SATEL-LP product family 24.11.2015 V1.6 SATEL LP -radio units SATEL-LP24 License free 2.4 GHz (2.4002 GHz... 2.4785 GHz) ISM (Industrial, Scientific and Medical) band, FHSS (Frequency Hopping Spread Spectrum)

More information

MACX MCR-EX-SL-NAM-2RO(-SP)

MACX MCR-EX-SL-NAM-2RO(-SP) Intrinsically safe NAMUR isolating amplifier with two relay outputs INTERFACE Data sheet 03465_en_00 PHOENIX CONTACT - 08/008 Description The NAMUR MACX MCR-EX-SL-NAM-RO(-SP) isolating amplifier has been

More information

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description. Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

elettriche DataSheet Zeus Link_Wi-Fi_EN

elettriche DataSheet Zeus Link_Wi-Fi_EN Zeus Link Wi-Fi Wireless AP Bridge/Client/Router 230 Vac Power supply Small footprint: 1 DIN module only Fast Ethernet Interface USB 2.0 Mass storage interface to connect external 3G modem Firmware upgradable

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

onlinecomponents.com

onlinecomponents.com Repeater for RS-485 2-Wire Systems INTERFACE Data Sheet 102964_C01_en 1 Description The PSI-REP-RS485W2 DIN-rail mountable, modular RS-485 repeater is designed to meet the high requirements associated

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features IGAP-620 / IGAP-620+ Industrial IEEE 802.11 a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 300Mbps link speed Highly Security

More information

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX 1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas -PS-100-240AC/24/5/EX POWER provides: Preventive function monitoring through professional signaling Global use due to a

More information

Honeywell OneWireless Network and Multinode Specifications EP November 2007

Honeywell OneWireless Network and Multinode Specifications EP November 2007 Honeywell OneWireless Network and Multinode Specifications EP03-610-100 1 November 2007 Honeywell s OneWireless Network is a universal and multi-functional wireless mesh network that supports field I/O,

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

General Specifications

General Specifications General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

General Specifications

General Specifications General Specifications YFGW710 Field Wireless Integrated Gateway GENERAL This General Specification (GS) describes the hardware specifications for Field Wireless Integrated Gateway and specifications of

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for IAP-320 / IAP-320+ Industrial IEEE 802.11 a/b/g wireless access point with 2x10/100Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 54Mbps link speed Highly Security Capability:

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

Industrial IEEE b/g/n wireless access point with 2x10/100Base-T(X) Features

Industrial IEEE b/g/n wireless access point with 2x10/100Base-T(X) Features IAP-420 / IAP-420+ Industrial IEEE 802.11 b/g/n wireless access point with 2x10/100Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 150 Mbps link speed Highly Security Capability:

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

SATEL-LP-PT100. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description

SATEL-LP-PT100. I/O extension module, 4 temperature inputs (Pt 100) Data sheet. 1 Description I/O extension module, 4 temperature inputs (Pt 100) ata sheet 106934_en_01 PHOENIX CONTCT 2016-12-07 1 escription The I/O extension module can be used in conjunction with STEL-LP wireless modules. In a

More information

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description Primaryswitched power supply unit Data sheet 105549_en_00 PHOENIX CONTACT 20130405 1 Description The UNO POWER power supply unit impresses in worldwide use thanks to maximum energy efficiency. Low noload

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation.

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation. THE INDUSTRIAL NETWORK COMPANY 700 SERIES Industrial Wireless Radio 702-W The N-TRON 702-W Industrial Wireless Radio provides outstanding performance and extreme reliability under the harshest industrial

More information

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK Siemens AG 2010 Network transitions /2 Transition from Industrial Ethernet to WirelessHART /2 Siemens IK PI News January 2010 Network transitions Overview General data HART (Highway Addressable Remote

More information

Surge protection for transceiver systems

Surge protection for transceiver systems 162 PHOENIX CONTACT Surge protection for transceiver systems Main range 164 Features 166 Selection guide 168 Exposed antenna systems and outdoor cables that extend beyond a building are particularly at

More information

IGAR G is a reliable IEEE a/b/g/n WLAN VPN router with 2 ports 10/100/1000Base-T(X) router where

IGAR G is a reliable IEEE a/b/g/n WLAN VPN router with 2 ports 10/100/1000Base-T(X) router where IGAR-1062+-4G Industrial IEEE 802.11 a/b/g/n 4G LTE Cellular Router with 2x10/100/1000Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 300Mbps link speed Provide 2 port 10/100/1000Base-T(X)

More information

FL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm)

FL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm) FO converter with SC duplex fiber optic connection (300 nm), for converting 0/00Base-T(X) to single-mode fiberglass (9/25 μm) Data sheet 04980_en_02 PHOENIX CONTACT 203-2-7 Description The FL MC EF 300

More information