PSI-GPRS/GSM-MODEM/RS232- QB
|
|
- Clare Johnson
- 5 years ago
- Views:
Transcription
1 PSI-GPRS/GSM-MODEM/RS232- QB Serial mobile communication modem for GSM and GPRS Data sheet _en_03 PHOENIX CONTACT Description The DIN-rail-mountable PSI-GPRS/GSM-MODEM/RS232- QB mobile communication modem is specifically designed to meet industrial requirements for remote communication and alarm generation. It provides global access to machines and systems via GSM connections. Comprehensive security functions prevent unauthorized access. The configurable warning and alarm inputs are a particularly useful feature for remote system monitoring. If these inputs are activated, the modem calls user-defined numbers and sends stored text messages by fax and/or SMS. You can also control additional functions using SMS messages on the switching output via the DIN rail connector. The focus is on EMC, electrical isolation, and surge protection for reliable and secure communication. The automatic sleep function ensures efficient battery operation. Features GPRS/EDGE quad band (850 MHz / 900 MHz / 1800 MHz / 1900 MHz) GPRS-TCP/IP connection: connection establishment via IP addresses Integrated TCP/IP stack for TCP and UDP connections Firewall GSM dial-up connection: connection establishment via user-defined numbers (CSD) Connection establishment with password protection, selective user-defined numbers, call-back function RS-232 interface that can be freely parameterized Two digital switching inputs: Sending of freely configurable text messages (SMS, FAX, ) Switching output via DIN rail connector Encryption of SIM card PINs Convenient configuration software Configuration via SMS Operation of the wireless system is only permitted when using accessories available from Phoenix Contact. The use of any other components can lead to the withdrawal of the operating license. You can find the approved accessories for this wireless system listed with the item at phoenixcontact.net/products. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This data sheet is valid for all products listed on the following page:
2 2 Table of contents 1 Description Table of contents Ordering data Technical data UL Notes Structure Function elements Text and telephone number memory _en_03 PHOENIX CONTACT 2
3 3 Ordering data Description Type Order No. Pcs./Pkt. Industrial GPRS/GSM modem for mounting on EN DIN rails. GSM and GPRS MHz. Serial V.24 (RS-232) interface. TCP/IP stack. Alarm input and output. 24 V DC supply voltage. PSI-GPRS/GSM-MODEM/RS232-QB Accessories Type Order No. Pcs./Pkt. GSM/UMTS antenna, with omnidirectional characteristic, 2 m antenna cable with SMA round connector GSM/UMTS antenna cable, 5 m long; SMA (male) -> SMA (female), 50 Ohm impendence GSM/UMTS antenna cable, 10 m long; SMA (male) -> SMA (female), 50 Ohm impendence GSM antenna for direct assembly on the device, angled antenna connector (90, SMA round connector). The antenna is suitable for installations in plastic control cabinets that are not visible externally. Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Plug component, Nominal current: 8 A, Nominal current (Ex): 8 A, Nominal voltage (Ex): 125 V, Number of positions: 5, Pitch: 3.81 mm, Articles with gold-plated contacts, bus connectors for connecting with electronic housings PSI-GSM/UMTS-QB-ANT PSI-CAB-GSM/UMTS- 5M PSI-CAB-GSM/UMTS-10M PSI-GSM-STUB-ANT MINI-SYS-PS AC/24DC/ ME 22,5 TBUS 1,5/ 5-ST-3,81 GN RS-232 cable, 9-pos. D-SUB socket on 9-pos. D-SUB socket, 9-wire, 1:1 PSM-KA9SUB9/BB/2METER RS-232 cable, 9-pos. D-SUB socket on 9-pos. D-SUB socket, 9-wire, 1:1 PSM-KA9SUB9/BB/0,5METER Connecting cable D-9-SUB to USB, with adapter D-9-SUB to D-25-SUB. CM-KBL-RS232/USB Adapter cable to connect the IB IL RS232 and IB IL RS232-PRO Inline communication terminals to the interface converter, e.g. modem, Com server, Bluetooth or fiber optics. PSM-KAD-IL RS232/9SUB/B/0,8M V.24 (RS-232) zero modem connector PSM-AD-D9-NULLMODEM Attachment plug with Lambda/4 technology as surge protection for coaxial signal interfaces. Connection: Male/female SMA connectors. Multiband mobile phone antenna with mounting bracket for outdoor installation. 5 m antenna cable with SMA round plug 4 Technical data CSMA-LAMBDA/4-2.0-BS-SET TC ANT MOBILE WALL 5M Supply Supply voltage range Nominal supply voltage Typical current consumption Electrical isolation Test voltage data interface/power supply 10 V DC V DC (via pluggable COMBICON screw terminal block) 24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply) < 350 ma (24 V DC) < 80 ma (stand by) VCC // RS-232 // GSM 1.5 kv (50 Hz, 1 min.) _en_03 PHOENIX CONTACT 3
4 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN Connection method Data format/encoding Transmission speed Transmission length Data flow control/protocols Compatibility Wireless interface Interface description Frequency Data rate D-SUB-9 plug Serial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length 1,2/2,4/9,6/19,2/38,4/57,6/115,2 kbit/s (can be set manually and automatically) 15 m Software handshake, Xon/Xoff or hardware handshake RTS/CTS AT standard and extended command set V.250 basic command set GSM / GPRS 850 MHz (2 W (EGSM)) 900 MHz (2 W (EGSM)) 1800 MHz (1 W (EGSM)) 1900 MHz (1 W (EGSM)) 85.6 kbps Antenna 50 impedance SMA antenna socket SIM Interface 1.8 volt, 3 volt GPRS Class 10, Class B CS1... CS4 Network function 4 time slots for receiving data, 2 time slots for transmitting data. The PIN is saved in the modem. After a voltage interruption, there is automatic redialing into the network Integrated TCP/IP stack, independent connection establishment. GSM CSD 9.6/14.4 kbps Compatibility V.34, V.32, V.22 bis, V.110 Network check LED to show data signal quality Input/output Description of the input Digital input Number of inputs 2 Voltage input signal 9 V DC V DC Current input signal 5 ma Output description Digital output Number of outputs 1 Voltage output signal 10 V DC V DC Current output signal 80 ma (24 V) General data Degree of protection Pollution degree 2 Dimensions (W/H/D) 22.5 mm x 99 mm x mm Housing material PA V0 green Free fall in acc. with IEC m Vibration resistance in acc. with EN /IEC g in each space direction Shock in acc. with EN /IEC Operation: 15g, 11 ms period, half-sine shock pulse Shock in acc. with EN /IEC Noise emission according to IP20 Storage: 30g, 11 ms period, half-sine shock pulse EN Noise immunity according to EN :2005 Electromagnetic compatibility Conformance with R&TTE directive 1999/5/EC _en_03 PHOENIX CONTACT 4
5 Ambient conditions Ambient temperature (operation) -25 C C Altitude Approvals / Certificates 5000 m (For restrictions see manufacturer's declaration) 2000 m (With UL approval) Conformance CE-compliant UL, USA / Canada culus listed UL 508 Class I, Zone 2, AEx na IIC T4 Class I, Zone 2, Ex na IIC T4 Gc X Conformance with R&TTE directive 1999/5/EC Noise immunity according to EN Electrostatic discharge EN Contact discharge ± 6 kv (Test intensity 3) Discharge in air ± 8 kv (Test intensity 3) Electromagnetic HF field EN Frequency range Test intensity 3 Field intensity 10 V/m Criterion A Fast transients (burst) EN Input ± 2 kv (Test intensity 3) Signal ± 1 kv (Test intensity 3) Surge current loads (surge) EN Input ± 2 kv Signal ± 1 kv Conducted interference EN Voltage 10 V Criterion A Emitted interference in acc. with EN Noise emission EN Class A, industrial applications Criterion A Normal operating behavior within the specified limits Temporary impairment of operating behavior that is corrected by the device itself R&TTE Directive 1999/5/EC EMC - immunity to interference (electromagnetic compatibility of wireless systems) Safety - protection of personnel with regard to electrical safety EN EN Generic standard for the industrial sector Health - limitation of exposure of the population to electromagnetic fields EC Gazette 1999/519/EC EC Council recommendation of July 12, 1999 Radio - effective use of the frequency spectrum and prevention of radio interference DIN EN _en_03 PHOENIX CONTACT 5
6 4.1 UL Notes INDUSTRIAL CONTROL EQUIPMENT 11AE Wire Range: AWG Cu Copper Wire, 60/75C Torque: 5-7 (Lbs-Ins) Environmental designation: "Open Type Device" "Pollution Degree 2 Installation Environment" Open Type - Process Control Equipment for use in Zone Classified Hazardous Locations A This equipment is suitable for use in Class I, Zone 2, AEx na IIC T4; Ex na IIC T4 Gc X or non-hazardous locations only. B Provision shall be made to prevent transient disturbances of more than 140 % of the rated supply voltage. C The device must be installed in a Class I, Zone 2 certified overall enclosure rated IP54 with tool-accessible only cover or door and in pollution degree 2 environment only. D Unit shall be supplied by Limited Energy circuit according to clause 9.4 of UL rd edition of Limited Power Source according to clause 2.5 of UL or NEC Class 2. E Conductor temperature rating must be 77 C or higher. F Maximum relative humidity 80 % for temperatures up to 31 C decreasing linearly to 50 % relative humidity at 40 C. G Antennas installed in end use are subject to the installation conditions of NEC 505, and inspection by the Authority Having Jurisdiction. Nominal voltage: 24 V DC, current: 190 ma Signaling output: RS-232, 2x V DC, 50 ma _en_03 PHOENIX CONTACT 6
7 5 Structure NOTE: device damage The device is only intended for operation in the control cabinet and with SELV according to IEC 60950/EN 60950/VDE The device may only be connected to devices, which meet the requirements of EN Function elements Status and diagnostics indicators 7 SIM Red ON SIM card not inserted Flashing PIN entry required 8 DCD Yellow ON Data carrier detected, connection established with partner 9 NET Yellow ON Very good network reception On, briefly flashing Good network reception Off, briefly flashing Moderate network reception OFF No network reception 10 ALR Red ON Alarm message was sent successfully Flashing Alarm message being sent 11 TD Green Transmit GSM interface data 12 RD Yellow Receive GSM interface data 13 VCC Green Flashing Supply voltage present 5.2 Text and telephone number memory Text memory SMS 160 characters Fax 160 characters Telephone number memory 10 telephone numbers with a maximum of 36 digits Figure 1 Function elements Plug-in screw terminal blocks 1 / 2 Supply voltage 3 Switching input 1 ( V DC) 4 Switching input 2 ( V DC) Interfaces 5 Antenna connection (SMA socket) 6 V.24 (RS-232) interface, 9-pos. D-SUB _en_03 PHOENIX CONTACT GmbH & Co. KG Blomberg Germany 7 phoenixcontact.com
PSI-GPRS/GSM-MODEM/RS232-QB
Extract from the online catalog PSI-GPRS/GSM-MODEM/RS232-QB Order No.: 2313106 Industrial GPRS/GSM modem for assembly on EN DIN rail. GSM and GPRS. 850 + 900 + 1800 + 1900 MHz. Serial RS-232 interface.
More informationPSI-MODEM-SHDSL/SERIAL
PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices
More informationPSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.
PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS
More informationTC MGUARD RS2000/4000 3G VPN
Industrial 3G (UMTS/HSPA/CDMA) security mobile phone router with integrated firewall, switch, and VPN Data sheet 105654_en_01 PHOENIX CONTACT 2015-02-11 1 Description The TC MGUARD RS2000/RS4000 3G VPN
More informationPSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description
Repeater for RS-485 2-wire bus systems Data sheet 100273_en_06 PHOENIX CONTACT 2016-09-09 1 Description The PSM-ME-RS485/RS485-P RS-485 repeater was developed for the high requirements of fieldbus systems.
More informationPSI-MODEM-SHDSL/SERIAL Copper Extender
PSI-MODEM-SHDSL/SERIAL Copper Extender perle.com /products/serial-extenders/psi-modem-shdsl-serial-extender.shtml RS232/422/485 over copper wire Transmit serial data up to 20km [12.4 mi] Two SHDSL ports
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationonlinecomponents.com
Repeater for RS-485 2-Wire Systems INTERFACE Data Sheet 102964_C01_en 1 Description The PSI-REP-RS485W2 DIN-rail mountable, modular RS-485 repeater is designed to meet the high requirements associated
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationRAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description
I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless
More informationMINI MCR-SL-UI-REL(-SP)
Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More informationMINI MCR-SL-PT100-UI(-SP)(-NC)
Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection
More informationTRIO-DIODE/12-24DC/2X10/1X20
Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy
More informationRAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description
I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline
More informationPSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems
Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch
More informationQUINT-BUFFER/24DC/24DC/40
Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module
More informationPSI-MOS-PROFIB/FO 850 T
Extract from the online catalog PSI-MOS-PROFIB/FO 850 T Order No.: 2708261 FO converter with integrated optical diagnosis, alarm contact, for PROFIBUS up to 12 MBit/s, T-coupler with two FO interfaces
More informationFL COMSERVER /422/485
Serial RS-232/RS-422/RS-485 device server for industrial 10/100 BASE-T(X) networks Data sheet 103827_en_08 PHOENIX CONTACT 2014-12-11 1 Description The FL COMSERVER... 232/422/485 enables the integration
More informationPHOENIX CONTACT - 04/2008
Serial Bluetooth adapter for a wireless connection of a serial interface to a Bluetooth access point AUTOMATION Data Sheet 7660_en_01 PHOENIX CONTACT - 04/2008 1 Description The FL BLUETOOTH Serial Port
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationPHOENIX CONTACT
SMS relay INTERFACE Data sheet 103892_en_03 PHOENIX CONTACT - 2011-06-17 1 Description The PSI-MODEM-SMS-REL... is a compact remote control and signaling system. Six digital or configurable analog/digital
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description
(-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase
More informationTU531, TU532 Terminal Unit
Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,
More informationMINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:
Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration
More informationVL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features
A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.
More informationINTERFACE. User Manual UM EN PSI-GPRS/GSM-MODEM/ RS232-QB. GPRS/GSM Modem
INTERFACE User Manual UM EN PSI-GPRS/GSM-MODEM/ RS232-QB GPRS/GSM Modem INTERFACE User Manual GPRS/GSM Modem 10/2008 Designation: Revision: UM EN PSI-GPRS/GSM-MODEM/RS232-QB B Order No.: This user manual
More informationPHOENIX CONTACT - 11/2008
The small form-factor pluggable module (SFP module) is a plug-in input/output module for fiber optics that is used in Gigabit Ethernet AUTOMATION Data Sheet 7762_en_01 PHOENIX CONTACT - 11/2008 1 Description
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationMINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description
3-way signal conditioner Data sheet 106012_en_02 PHOENIX CONTACT 2016-02-19 1 Description The standard signal 3-way signal conditioner with pluggable connection technology is used to electrically isolate,
More informationRAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description
WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C 1 Description PHOENIX CONTACT 2011-06-07 2 Features The RAD-WHG/WLAN-XD is a WirelessHART gateway with integrated 802.11b/g
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationMINI MCR-SL-CVS NC
Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also
More informationDI572 Digital Input Module
Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968
More informationPSI-MOS-RS422/FO 850 T
Extract from the online catalog PSI-MOS-RS422/FO 850 T Order No.: 2708397 FO converter with integrated optical diagnosis, alarm contact, for RS-422/RS-485 4-wire/ INTERBUS to 2 Mbit/s, T-coupler with two
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationEZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V
EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation
More informationFL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm)
FO converter with SC duplex fiber optic connection (300 nm), for converting 0/00Base-T(X) to single-mode fiberglass (9/25 μm) Data sheet 04980_en_02 PHOENIX CONTACT 203-2-7 Description The FL MC EF 300
More informationVL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.
A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationPower Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5
Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationPHOENIX CONTACT - 10/2009
Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used
More informationFL MC 10/100BASE-T/FO-660
Extract from the online catalog FL MC 10/100BASE-T/FO-660 Order No.: 2708193 FO converter, for converting 10/100Base-T to polymer and HCS fiber, (660 nm), SCRJ FO connection (PROFINET standard), rail-mountable,
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationAI561 Analog Input Module
Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968
More informationAO561 Analog Output Module
Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal
More informationPower Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1
Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationPSR-PS21. SIL coupling relay. Data sheet. 1 Description
SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand
More informationXPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term
Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W
More informationDI561 Digital Input Module
Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital
More informationAO523 Analog Input Module
Ordering Data DATA SHEET AO523 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 200 R0001 1SAP 450 200 R0001 AO523, analog output module, 16 AO, U/I, 12 bits
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationUNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description
Primaryswitched power supply unit Data sheet 105549_en_00 PHOENIX CONTACT 20130405 1 Description The UNO POWER power supply unit impresses in worldwide use thanks to maximum energy efficiency. Low noload
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationFL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C
16-Port Standard Function Ethernet Switches for Normal and Extreme Environments AUTOMATION Data Sheet 2806_en_C 1 Description PHOENIX CONTACT 2011-06-28 2 Features and Benefits The FL SWITCH SFN(T) 16(15)(14)TX
More informationMINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial
More informationCM597 Ethernet Communication Module
Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet
More informationDC561, digital input/output module,
Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,
More informationDC562, digital input/output module,
Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationValueline Industrial PC
A configurable industrial computer platform AUTOMATION Data Sheet 2643_en_F 1 Description PHOENIX CONTACT 2011-07-15 2 Features The Valueline Industrial PC (VL IPC) product line is a configurable industrial
More informationPSI-MOS-PROFIB/FO 850 T
Extract from the online catalog PSI-MOS-PROFIB/FO 850 T Order No.: 2708261 FO converter with integrated optical diagnosis, alarm contact, for PROFIBUS up to 12 MBit/s, T-coupler with two FO interfaces
More informationRE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O
Characteristics On-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts
More informationRE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O
Characteristics Off-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts
More informationRE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O
Characteristics Star-Delta Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts
More informationIBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B
Controller Board for PC Systems With PCI Bus Data Sheet 6039B 01/2002 Product Description INTERBUS Generation 4 controller board with a host interface for the PCI bus. Features INTERBUS protocol (IEC 6
More informationFL MC EF 1300 MM ST. FO converter with B-FOC (ST ) connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm)
FO converter with B-FOC (ST ) connection (300 nm), for converting 0/00Base-T(X) to multi-mode fiberglass (50/25 µm) Data sheet 0494_en_02 PHOENIX CONTACT 203-2-6 Description The FO converter provides a
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationDX561 Digital Input/Output Module
Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI
More informationFL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.
Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches
More informationAI531 Analog Input Module
Ordering Data DATA SHEET AI531 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 600 R0001 AI531, analog input module, 8 AI, U/I/Pt100, TC, 15 bits + sign, 4-wires
More informationPSR-PC20. SIL coupling relay. Data sheet. 1 Description
SIL coupling relay Data sheet 106255_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The PSR-PC20 SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand
More informationOutput Voltage* (nom.)(adjustable)
Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to
More informationTM3DI16 module TM3-16 inputs
Characteristics module TM3-16 inputs Main Range of product Product or component type Range compatibility Jun 30, 2018 Modicon TM3 Discrete input module Modicon M241 Modicon M251 Modicon M221 Discrete input
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationRAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.
I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs INTERFACE Data sheet 104832_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DAIO6-IFS I/O extension module can be
More informationQUINT-PS-3x AC/24DC/10
3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range
More informationCM592 PROFIBUS Communication Module
Ordering Data DATA SHEET CM592 PROFIBUS Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 200 R0001 1SAP 373 200 R0001 CM592-DP, communication module PROFIBUS
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector
Characteristics expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More information