DS6300 QUICK REFERENCE GUIDE

Size: px
Start display at page:

Download "DS6300 QUICK REFERENCE GUIDE"

Transcription

1 DS600 QUICK REFERENCE GUIDE

2 CONTENTS DS MASTER/SLAVE MODEL... DS PROFIBUS MODEL...8 DS ETHERNET MODEL... DS DEVICENET MODEL...8 DS XX OSCILLATING MIRROR MODEL... COMMON FEATURES...5 NOTE For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product. SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to and click on the links indicated for further information including: PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - Genius a utility program, which allows device configuration using a PC. It provides RS interface configuration. SERVICES & SUPPORT - Datalogic Services - Warranty Extensions and Maintenance Agreements - Authorised Repair Centres CONTACT US form and listing of Datalogic Subsidiaries

3 DS600 MASTER/SLAVE MODEL DS MASTER/SLAVE MODEL Figure A Laser Beam Output Window 5 Figure B Figure C Programming Keypad Power On LED (Red) Main/Aux. Interface 5-pin D-sub Male Connector TX Data LED (Green) 5 LCD Display Lonworks 9-pin Male Connector Phase On LED (Yellow) Lonworks 9-pin Female Connector Available Models: Optical Model 0 = Standard 5 = Oscillating Mirror DS600-0X - 0YY Decoder Model 0 = Master/Slave = Profibus = Ethernet 5 = Devicenet Technical Features: ELECTRICAL FEATURES OPTICAL FEATURES Supply Voltage 5-0 Vdc Light Receiver Avalanche photodiode Power Consumption 5 W typical 0 W Max. (including startup current) Wavelength 60 to 680 nm Safety Class Class -EN 6085-; Class II-CDRH Communication Main (isolated) Baud Rate Interfaces RS Laser Control Security system to turn laser RS85 full-duplex 00 to 500 off in case of motor slow down RS85 half-duplex READING FEATURES 0 ma C.L. (INT-0 with C-BOX 00 only) 900 Scan Rate scans/s Auxiliary Max. Resolution RS 00 to 50 Max. Read. Distance Other Max. Read. Width (see reading diagram) Lonworks.5 Mb/s Max. Depth of Field Inputs Ext. Trigger, aux. digital (optocoupled NPN or PNP) USER INTERFACE inputs LCD Display lines by 6 characters LCD Outputs Keypad keys software LED Indicators Power ON (red) programmable (optocoupled) Phase ON (yellow) digital outputs TX Data (green)

4 DS600 MASTER/SLAVE MODEL SOFTWARE FEATURES ENVIRONMENTAL FEATURES Readable Codes Interleaved /5 Operating 0 to +0 C Code 9 standard Temperature (+ to +0 F) Codabar -0 to +70 C Storage Temperature Code 8 (- to +58 F) EAN 8 Humidity 90% non condensing Code 9 (Standard & Full ASCII) Ambient Light EAN/UPC (including Add-on and Immunity 500 lux Add-on 5) Vibration Resistance to 0Hz Code Selection Up to 0 codes during one reading IEC test FC.5 to 55 Hz phase 70 to 00 Hz hours on each axis Headers and Up to 8-byte headers and8- Shock Resistance 0 g; ms Terminators byte terminators IEC test EA shocks on each axis Operating Protection Class IP6 On Line, Automatic, Test Modes Config. Mode Genius utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Std Models Oscill. Mirror Dimensions mm (inch) 0xx99 (.x.5x.9) x80x0.5 (.5x7.08x.) Weight.5 kg (. lb).0 kg (. lb) Accessories: Name Description Part Number CAB-600 Cable to C-BOX00 m 9A0590 CAB-600 Cable to C-BOX00 m 9A0500 CAB-6005 Cable to C-BOX00 5 m 9A050 CAB-600 Cable to C-BOX00 0 m 9A057 CAB-60 Cable master/slave m 9A050 CAB-60 Cable master/slave m 9A050 CAB-605 Cable master/slave 5 m 9A050 CAB-6 Cable master/slave no power m 9A05 CAB-65 Cable master/slave no power 5 m 9A055 CAB-605 Power cable Fam 6k 5 m 9ACC768 CAB-60 Power cable Fam 6k 0 m 9ACC75 C-BOX 00 Passive connection box 9ACC50 INT-0 0 ma C.L. interface board for C-BOX 00 9A50 GFC mirror 9A000 GFC mirror close distance 9A00 GFX-60 X-pattern mirror 9ACC70 PWR-0 Power unit 0/0 V AC - V DC 9ACC50 BTK-6000 Terminator kit (5 pcs) 9ACC70 PG600 Single unit power supply US 9ACC78 PG600 Single unit power supply UK 9ACC79 PG6000 Single unit power supply EU 9ACC70 FBK-6000 Fast bracket kit ( pcs) 9ACC7 US-60 Mounting bracket kit (5 pcs) for multisided stations 9ACC79 PH- Photocell kit - PNP 9ACC79 MEP-5 Photocell kit - NPN 9ACC78 OEK- Optical encoder (0 m cable + spring) 9ACC770 OEK- Optical encoder kit + 0 m cable 9ACC600 Electrical Connections: The DS600 reader provides a 5-pin male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. Two 9-pin connectors provide access to the scanner s local Lonworks network used for both input and output connections to build a multi-sided or omni-station system.

5 DS600 MASTER/SLAVE MODEL The details of the connector pins are indicated in the following table: 5-pin D-Sub Connector Pinout Pin Name Function CHASSIS Chassis - internally connected to GND Cable shield connected to chassis 0 RXAUX Receive data of auxiliary RS (referred to GND) TXAUX Transmit data of auxiliary RS (referred to GND) 8 OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin 6 OUT A Configurable digital output polarity insensitive 7 OUT B Configurable digital output polarity insensitive 8 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 9 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN/ENC A Input signal (polarity insensitive) for Encoder 0 IN/ENC B Input signal (polarity insensitive) for Encoder INA Input signal (polarity insensitive) 5 INA Input signal (polarity insensitive) IN_REF Common reference of IN and IN (polarity insensitive) 9, VS Supply voltage positive pin, 5 GND Supply voltage negative pin Pin RS RS85 Full-Duplex RS85 Half-Duplex TX TX85+ RTX85+ RX * RX85+ RTS TX85- RTX85-5 CTS * RX85-7 GND_ISO GND_ISO GND_ISO * Do not leave floating, see Reference Manual for connection details. 5 5-pin male D-sub Connector 0 ma C.L. (INT-0 with C-BOX 00 only) see INT-0 instructions 9-pin Lonworks Connector Pinout Pin Name Function CHASSIS Cable shield internally connected by capacitor to chassis 9 VS Supply voltage positive pin GND Supply voltage negative pin 6 VS_I/O Supply voltage of I/O circuit Ref_I/O Reference voltage of I/O circuit SYS_ENC_I/O System signal 5 SYS_I/O System signal 7 LON A Lonworks line (polarity insensitive) 8 LON B Lonworks line (polarity insensitive) Female Male 9-pin Local Lonworks Connectors Network Termination: When building a local Lonworks system the network must be properly terminated by positioning a BTK-6000 terminator on the DS600 master reader (BTK-6000 female side) and on the last slave reader (BTK-6000 male side). to Master to Slave 9-pin female 9-pin male BTK-6000 Network Terminator

6 DS600 MASTER/SLAVE MODEL Connectivity: Point-to-Point Layout DS600 CAB-600X C-BOX 00 Local Host *P.S. PG6000 * P.S. (Presence Sensor) connected to External Trigger/PS input. Pass Through Layout *P.S. *P.S. Gryphon DS600 ENT DS600A ENT DS600A CAB-600X C-BOX 00 C-BOX 00 C-BOX 00 MAIN AUX *P.S. Local Host PWR-0 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input.

7 DS600 MASTER/SLAVE MODEL *P.S. *P.S. Multiplexer Layout *P.S. DS600 ENT DS600A ENT DS600A PWR-0 CAB-600X C-BOX 00 C-BOX 00 C-BOX 00 MX000 # #0 # Local Host RS85 HD Main Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. RS Master/Slave Layout DS600 Master CAB-600X C-BOX 00 DS600A Slave ENT *P.S. Local Host C-BOX 00 DS600A Slave ENT PWR-0 C-BOX 00 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. 5

8 DS600 MASTER/SLAVE MODEL Local Lonworks Network CAB-60X CAB-60XX BTK-6000 C-BOX 00** Master Encoder*** BTK-6000 Slave *P.S. Local Host CAB-6XX PWR-0 Small Synchronized Network with Readers * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 00 modified to accept scanner power. *** Encoder connected to IN/ENC input. Slave Slave Local Lonworks Network Master CAB-60X CAB-60X BTK-6000 C-BOX 00** CAB-600X *P.S. CAB-60X Encoder*** CAB-60X CAB-60X Host BTK-6000 CAB-6XX Slave 5 Slave Slave PWR-0 CAB-6XX Small Synchronized Network with more than Readers and Single Power Unit * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 00 modified to accept scanner power. *** Encoder connected to IN/ENC input. 6

9 DS600 MASTER/SLAVE MODEL Large Synchronized Network ** * * P.S. (Presence Sensor) connected to External Trigger/PS input. ** Encoder connected to ENC input. Large Synchronized Network with DX6X00 and DS6XXX Scanners 7

10 DS600 PROFIBUS MODEL DS PROFIBUS MODEL Figure A Laser Beam Output Window 5 Figure B Figure C Programming Keypad Power On LED (Red) Profibus 9-pin Female Connector (white) TX Data LED (Green) 5 LCD Display Lonworks 9-pin Female Connector Phase On LED (Yellow) Main/Aux. Interface 6-pin D-Sub Male Connector Available Models: Optical Model 0 = Standard 5 = Oscillating Mirror DS600-0X - 0YY Decoder Model 0 = Master/Slave = Profibus = Ethernet 5 = Devicenet Technical Features: ELECTRICAL FEATURES OPTICAL FEATURES Supply Voltage 5-0 Vdc Light Receiver Avalanche photodiode Power Consumption 5 W typical 0 W Max. (including startup current) Wavelength 60 to 680 nm Communication Interfaces Main (isolated) RS RS85 full-duplex RS85 half-duplex 0 ma C.L. (INT-0 with C-BOX 00 only) Auxiliary Baud Rate 00 to 500 RS 00 to 500 Other Lonworks.5 Mb/s Profibus Mb/s Safety Class Class -EN 6085-; Class II-CDRH Laser Control READING FEATURES Security system to turn laser off in case of motor slow down 900 Scan Rate scans/s Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field (see reading diagram) Inputs Ext. Trigger, aux. digital (optocoupled NPN or PNP) USER INTERFACE inputs LCD Display lines by 6 characters LCD Outputs Keypad keys software LED Indicators Power ON (red) programmable (optocoupled) Phase ON (yellow) digital outputs TX Data (green) 8

11 DS600 PROFIBUS MODEL SOFTWARE FEATURES ENVIRONMENTAL FEATURES Readable Codes Interleaved /5 Operating 0 to +0 C Code 9 standard Temperature (+ to +0 F) Codabar -0 to +70 C Storage Temperature Code 8 (- to +58 F) EAN 8 Humidity 90% non condensing Code 9 (Standard & Full ASCII) Ambient Light EAN/UPC (including Add-on and Immunity 500 lux Add-on 5) Vibration Resistance to 0Hz Code Selection Up to 0 codes during one reading IEC test FC.5 to 55 Hz phase 70 to 00 Hz hours on each axis Headers and Up to 8-byte headers and8- Shock Resistance 0 g; ms Terminators byte terminators IEC test EA shocks on each axis Operating Protection Class IP6 On Line, Automatic, Test Modes Config. Mode Genius utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Std Models Oscill. Mirror Dimensions mm (inch) 0xx99 (.x.5x.9) x80x0.5 (.5x7.08x.) Weight.5 kg (. lb).0 kg (. lb) Accessories: Name Description Part Number CAB-60 Cable to C-BOX00 m 9A05 CAB-60 Cable to C-BOX00 m 9A05 CAB-605 Cable to C-BOX00 5 m 9A05 C-BOX 00 Passive connection box 9ACC50 INT-0 0 ma C.L. interface board for C-BOX 00 9A50 GFC mirror 9A000 GFC mirror close distance 9A00 GFX-60 X-pattern mirror 9ACC70 PWR-0 Power unit 0/0 V AC - V DC 9ACC50 BTK-6000 Terminator kit (5 pcs) 9ACC70 PG600 Single unit power supply US 9ACC78 PG600 Single unit power supply UK 9ACC79 PG6000 Single unit power supply EU 9ACC70 FBK-6000 Fast bracket kit ( pcs) 9ACC7 US-60 Mounting bracket kit (5 pcs) for multisided stations 9ACC79 PH- Photocell kit - PNP 9ACC79 MEP-5 Photocell kit NPN 9ACC78 OEK- Optical encoder (0 m cable + spring) 9ACC770 OEK- Optical encoder kit + 0 m cable 9ACC600 Electrical Connections: The DS600 Profibus reader provides a 6-pin male D-sub connector for connection to power supply and input/output signals. An 9-pin Profibus connector is used for connection to the remote Host, while a local Lonworks 9-pin female connector connects the Profibus master to the first slave reader of the system. The details of the connector pins are indicated in the following table: 9

12 DS600 PROFIBUS MODEL 6-pin D-Sub Connector Pinout Pin Name Function CHASSIS Chassis - internally connected to GND Cable shield connected to chassis 0 RXAUX Receive data of auxiliary RS (referred to GND) TXAUX Transmit data of auxiliary RS (referred to GND) 8 OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin 9 6 OUT A Configurable digital output polarity insensitive OUT B Configurable digital output polarity insensitive EXT_TRIG/PS A External trigger (polarity insensitive) for PS 9 EXT_TRIG/PS B External trigger (polarity insensitive)for PS 6-pin male D-sub Connector 6 IN/ENC A Input signal (polarity insensitive) for Encoder 0 IN/ENC B Input signal (polarity insensitive) for Encoder INA Input signal (polarity insensitive) 5 INA Input signal (polarity insensitive) IN_REF Common reference of IN and IN (polarity insensitive) 9, VS Supply voltage positive pin, 5, 6 GND Supply voltage negative pin Pin RS RS85 Full-Duplex RS85 Half-Duplex TX TX85+ RTX85+ RX * RX85+ RTS TX85- RTX85-5 CTS * RX85-7 GND_ISO GND_ISO GND_ISO * Do not leave floating, see Reference Manual for connection details. 0 ma C.L. (INT-0 with C-BOX 00 only) see INT-0 instructions 9-pin Lonworks Connector Pinout Pin Name Function CHASSIS Cable shield internally connected by capacitor to chassis 9 VS Supply voltage positive pin GND Supply voltage negative pin 6 VS_I/O Supply voltage of I/O circuit Ref_I/O Reference voltage of I/O circuit SYS_ENC_I/O System signal 5 SYS_I/O System signal 7 LON A Lonworks line (polarity insensitive) 8 LON B Lonworks line (polarity insensitive) pin female Local Lonworks Connector 9-pin Profibus Connector Pin Name Function Shield Shield, Protective Ground resp. (optional) Free B-LINE (RxD/TxD-P) Received/Transmitted Data-P CNTR-P Repeater Control Signal (optional, RS85 level) 5 DGND Data Ground (M5V) 6 +5 V Voltage Plus (P5V) 7 Free 8 A-LINE (RxD/TxD-N) Received/Transmitted Data 9 CNTR-N Repeater Control Signal pin female Profibus Connector (white) 0

13 DS600 PROFIBUS MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS600 C-BOX 00 CAB-60X *P.S PG6000 * P.S. (Presence Sensor) connected to External Trigger/PS input. Remote Host Pass Through Layout *P.S. *P.S. Gryphon DS600 Fieldbus Network ENT DS600A ENT DS600A CAB-60X C-BOX 00 C-BOX 00 AUX C-BOX 00 *P.S. PWR-0 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input.

14 DS600 PROFIBUS MODEL Local Lonworks Network Remote Host Fieldbus Network Slave *** Slave *** Master C-BOX 00** CAB-60X CAB-60X CAB-60X CAB-60XX P.S.* CAB-60X BTK-6000 CAB-60X CAB-6XX Encoder**** Slave 5*** Slave *** Slave *** PWR-0 CAB-6XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 00 modified to accept scanner power. *** The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN/ENC input.

15 DS600 ETHERNET MODEL DS ETHERNET MODEL Figure A Laser Beam Output Window 5 Figure B Figure C Programming Keypad Power On LED (Red) RJ5 Modular Connector for Ethernet Interface TX Data LED (Green) 5 LCD Display Lonworks 9-pin Female Connector Phase On LED (Yellow) Main/Aux. Interface 6-pin D-Sub Male Connector Available Models: Optical Model 0 = Standard 5 = Oscillating Mirror DS6500-0X - 0YY Decoder Model 0 = Master/Slave = Profibus = Ethernet 5 = Devicenet Technical Features: ELECTRICAL FEATURES OPTICAL FEATURES Supply Voltage 5-0 Vdc Light Receiver Avalanche photodiode Power 5 W typical Wavelength 60 to 680 nm Consumption 0 W Max. (including startup current) Safety Class Class -EN 6085-; Class II- Communication Main (isolated) Baud Rate CDRH Interfaces RS Laser Control Security system to turn laser RS85 full-duplex 00 to 500 off in case of motor slow down RS85 half-duplex READING FEATURES 0 ma C.L. (INT-0 with C-BOX 00 only) 900 Scan Rate scans/s Auxiliary RS 00 to 500 Max. Resolution Other Lonworks.5 Mb/s Max. Read. Distance Max. Read. Width (see reading diagram) Ethernet 0 or 00 Mb/s Max. Depth of Field Inputs Ext. Trigger, aux. digital (optocoupled NPN or PNP) USER INTERFACE inputs LCD Display lines by 6 characters LCD Outputs Keypad keys software programmable digital outputs (optocoupled) LED Indicators Power ON (red) Phase ON (yellow) TX Data (green)

16 DS600 ETHERNET MODEL SOFTWARE FEATURES ENVIRONMENTAL FEATURES Readable Codes Interleaved /5 Operating 0 to +0 C Code 9 standard Temperature (+ to +0 F) Codabar -0 to +70 C Storage Temperature Code 8 (- to +58 F) EAN 8 Humidity 90% non condensing Code 9 (Standard & Full ASCII) Ambient Light EAN/UPC (including Add-on and Immunity 500 lux Add-on 5) Vibration Resistance to 0Hz Code Selection Up to 0 codes during one reading IEC test FC.5 to 55 Hz phase 70 to 00 Hz hours on each axis Headers and Up to 8-byte headers and8- Shock Resistance 0 g; ms Terminators byte terminators IEC test EA shocks on each axis Operating Protection Class IP50 On Line, Automatic, Test Modes Config. Mode Genius utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Std Models Oscill. Mirror Dimensions mm (inch) 0xx99 (.x.5x.9) x80x0.5 (.5x7.08x.) Weight.5 kg (. lb).0 kg (. lb) Accessories: Name Description Part Number CAB-60 Cable to C-BOX00 m 9A05 CAB-60 Cable to C-BOX00 m 9A05 CAB-605 Cable to C-BOX00 5 m 9A05 C-BOX 00 Passive connection box 9ACC50 INT-0 0 ma C.L. interface board for C-BOX 00 9A50 GFC mirror 9A000 GFC mirror close distance 9A00 GFX-60 X-pattern mirror 9ACC70 PWR-0 Power unit 0/0 V AC - V DC 9ACC50 BTK-6000 Terminator kit (5 pcs) 9ACC70 PG600 Single unit power supply US 9ACC78 PG600 Single unit power supply UK 9ACC79 PG6000 Single unit power supply EU 9ACC70 FBK-6000 Fast bracket kit ( pcs) 9ACC7 US-60 Mounting bracket kit (5 pcs) for multisided stations 9ACC79 PH- Photocell kit - PNP 9ACC79 MEP-5 Photocell kit NPN 9ACC78 OEK- Optical encoder (0 m cable + spring) 9ACC770 OEK- Optical encoder kit + 0 m cable 9ACC600 Electrical Connections: The DS600 Ethernet reader provides a 6-pin male D-sub connector for connection to power supply and input/output signals. An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the system. The details of the connector pins are indicated in the following table:

17 DS600 ETHERNET MODEL 6-pin D-Sub Connector Pinout Pin Name Function CHASSIS Chassis - internally connected to GND Cable shield connected to chassis 0 RXAUX Receive data of auxiliary RS (referred to GND) TXAUX Transmit data of auxiliary RS (referred to GND) 8 OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin 9 6 OUT A Configurable digital output polarity insensitive OUT B Configurable digital output polarity insensitive EXT_TRIG/PS A External trigger (polarity insensitive) for PS 9 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6-pin male D-sub Connector 6 IN/ENC A Input signal (polarity insensitive) for Encoder 0 IN/ENC B Input signal (polarity insensitive) for Encoder INA Input signal (polarity insensitive) 5 INA Input signal (polarity insensitive) IN_REF Common reference of IN and IN (polarity insensitive) 9, VS Supply voltage positive pin, 5, 6 GND Supply voltage negative pin Pin RS RS85 Full-Duplex RS85 Half-Duplex TX TX85+ RTX85+ RX * RX85+ RTS TX85- RTX85-5 CTS * RX85-7 GND_ISO GND_ISO GND_ISO * Do not leave floating, see Reference Manual for connection details. 0 ma C.L. (INT-0 with C-BOX 00 only) see INT-0 instructions 9-pin Lonworks Connector Pinout Pin Name Function CHASSIS Cable shield internally connected by capacitor to chassis 9 VS Supply voltage positive pin GND Supply voltage negative pin 6 VS_I/O Supply voltage of I/O circuit Ref_I/O Reference voltage of I/O circuit SYS_ENC_I/O System signal 5 SYS_I/O System signal 7 LON A Lonworks line (polarity insensitive) 8 LON B Lonworks line (polarity insensitive) pin female Local Lonworks Connector DS600 HUB / SWITCH RJ5 Modular Connector TX+ TX- RX+ 8 n. c. n. c. 5 5 RX- 6 6 n. c. n. c RJ5 Modular Connector n. c. = not connected 5

18 DS600 ETHERNET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS600 C-BOX 00 CAB-60X *P.S PG6000 * P.S. (Presence Sensor) connected to External Trigger/PS input. Remote Host Pass Through Layout *P.S. *P.S. Gryphon DS600 Fieldbus Network ENT DS600A ENT DS600A CAB-60X C-BOX 00 C-BOX 00 AUX C-BOX 00 *P.S. PWR-0 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input. 6

19 DS600 ETHERNET MODEL Local Lonworks Network Remote Host Fieldbus Network Slave *** Slave *** Master C-BOX 00** CAB-60X CAB-60X CAB-60X CAB-60XX P.S.* CAB-60X BTK-6000 CAB-60X CAB-6XX Encoder**** Slave 5*** Slave *** Slave *** PWR-0 CAB-6XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 00 modified to accept scanner power. *** The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN/ENC input. 7

20 DS600 DEVICENET MODEL DS DEVICENET MODEL Figure A Laser Beam Output Window 5 Figure B Figure C Programming Keypad TX Data LED (Green) Phase On LED (Yellow) 5 Power On LED (Red) LCD Display Main/Aux. Interface 6-pin D-sub Male Connector Lonworks 9-pin Female Connector DeviceNet 5-pin Male Connector Available Models: Optical Model 0 = Standard 5 = Oscillating Mirror DS600-0X - 0YY Decoder Model 0 = Master/Slave = Profibus = Ethernet 5 = Devicenet Technical Features: ELECTRICAL FEATURES OPTICAL FEATURES Supply Voltage 5-0 Vdc Light Receiver Avalanche photodiode Power Consumption Wavelength 60 to 680 nm Communication Interfaces 5 W typical 0 W Max. (including startup current) Safety Class Class -EN 6085-; Class II-CDRH Main (isolated) Baud Rate Laser Control Security system to turn laser RS RS85 full-duplex 00 to 500 RS85 half-duplex 0 ma C.L. (INT with C-BOX 00 only) Auxiliary RS 00 to 500 Other Lonworks.5 Mb/s DeviceNet 5 or 50 Kb/s Inputs Ext. Trigger, aux. digital inputs (optocoupled NPN or PNP) Outputs software programmable digital outputs (optocoupled) off in case of motor slow down READING FEATURES Scan Rate scans/s Max. Resolution Max. Read. Distance Max. Read. Width Max. Depth of Field USER INTERFACE LCD Display Keypad LED Indicators (see reading diagram) lines by 6 characters LCD keys Power ON (red) Phase ON (yellow) TX Data (green) 8

21 DS600 DEVICENET MODEL SOFTWARE FEATURES ENVIRONMENTAL FEATURES Readable Codes Interleaved /5 Operating 0 to +0 C Code 9 standard Temperature (+ to +0 F) Codabar -0 to +70 C Storage Temperature Code 8 (- to +58 F) EAN 8 Humidity 90% non condensing Code 9 (Standard & Full ASCII) Ambient Light EAN/UPC (including Add-on and Immunity 500 lux Add-on 5) Vibration Resistance to 0Hz Code Selection Up to 0 codes during one reading IEC test FC.5 to 55 Hz phase 70 to 00 Hz hours on each axis Headers and Up to 8-byte headers and8- Shock Resistance 0 g; ms Terminators byte terminators IEC test EA shocks on each axis Operating Protection Class IP6 On Line, Automatic, Test Modes Config. Mode Genius utility program Param. Storage Non-volatile internal FLASH PHYSICAL FEATURES Std Models Oscill. Mirror Dimensions mm (inch) 0xx99 (.x.5x.9) x80x0.5 (.5x7.08x.) Weight.5 kg (. lb).0 kg (. lb) Accessories: Name Description Part Number CAB-60 Cable to C-BOX00 m 9A05 CAB-60 Cable to C-BOX00 m 9A05 CAB-605 Cable to C-BOX00 5 m 9A05 C-BOX 00 Passive connection box 9ACC50 INT-0 0 ma C.L. interface board for C-BOX 00 9A50 GFC mirror 9A000 GFC mirror close distance 9A00 GFX-60 X-pattern mirror 9ACC70 PWR-0 Power unit 0/0 V AC - V DC 9ACC50 BTK-6000 Terminator kit (5 pcs) 9ACC70 PG600 Single unit power supply US 9ACC78 PG600 Single unit power supply UK 9ACC79 PG6000 Single unit power supply EU 9ACC70 FBK-6000 Fast bracket kit ( pcs) 9ACC7 US-60 Mounting bracket kit (5 pcs) for multisided stations 9ACC79 PH- Photocell kit - PNP 9ACC79 MEP-5 Photocell kit NPN 9ACC78 OEK- Optical encoder (0 m cable + spring) 9ACC770 OEK- Optical encoder kit + 0 m cable 9ACC600 Electrical Connections: The DS600 DeviceNet reader provides a 6-pin male D-sub connector for connection to power supply and input/output signals. A DeviceNet connector is used for connection to the remote Host, while a local Lonworks 9-pin female connector connects the DeviceNet master to the first slave reader of the system. NOTE When using DeviceNet, the Main serial interface is disabled and must not be physically connected. 9

22 DS600 DEVICENET MODEL The details of the connector pins are indicated in the following table: 6-pin D-Sub Connector Pinout Pin Name Function CHASSIS Chassis - internally connected to GND Cable shield connected to chassis 0 RXAUX Receive data of auxiliary RS (referred to GND) TXAUX Transmit data of auxiliary RS (referred to GND) 8 OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin OUT + Configurable digital output positive pin OUT - Configurable digital output negative pin 9 6 OUT A Configurable digital output polarity insensitive OUT B Configurable digital output polarity insensitive EXT_TRIG/PS A External trigger (polarity insensitive) for PS 9 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6-pin male D-sub Connector 6 IN/ENC A Input signal (polarity insensitive) for Encoder 0 IN/ENC B Input signal (polarity insensitive) for Encoder INA Input signal (polarity insensitive) 5 INA Input signal (polarity insensitive) IN_REF Common reference of IN and IN (polarity insensitive) 9, VS Supply voltage positive pin, 5, 6 GND Supply voltage negative pin Pin RS RS85 Full-Duplex RS85 Half-Duplex TX TX85+ RTX85+ RX * RX85+ RTS TX85- RTX85-5 CTS * RX85-7 GND_ISO GND_ISO GND_ISO * Do not leave floating, see Reference Manual for connection details. Pin Name Function 9-pin Lonworks Connector Pinout CHASSIS Cable shield internally connected by capacitor to chassis 9 VS Supply voltage positive pin GND Supply voltage negative pin 6 VS_I/O Supply voltage of I/O circuit Ref_I/O Reference voltage of I/O circuit SYS_ENC_I/O System signal 5 SYS_I/O System signal 7 LON A Lonworks line (polarity insensitive) 8 LON B Lonworks line (polarity insensitive) 5-pin DeviceNet Connector Pinout Pin Name Function V+ Supply voltage positive pin 5 CAN_L CAN bus data line L SHIELD Shield CAN_H CAN bus data line H V- Supply voltage negative pin ma C.L (INT-0 with C-BOX 00 only) see INT-0 instructions 9-pin female Local Lonworks Connector 5 5-pin male DeviceNet Connector NOTE The power supplied on pin V+ and V- is used only to propagate power to the section of the DeviceNet board directly connected to the Bus. It is completely isolated from the DS600 power which must be supplied on pin 9, and pin, 5 of the 6-pin Main/Aux connector. 0

23 DS600 DEVICENET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS600 C-BOX 00 CAB-60X *P.S PG6000 * P.S. (Presence Sensor) connected to External Trigger/PS input. Remote Host Pass Through Layout *P.S. *P.S. Gryphon DS600 Fieldbus Network ENT DS600A ENT DS600A CAB-60X C-BOX 00 C-BOX 00 AUX C-BOX 00 *P.S. PWR-0 Main Serial Interface Auxiliary Serial Interface * P.S. (Presence Sensor) connected to External Trigger/PS input.

24 DS600 DEVICENET MODEL Local Lonworks Network Remote Host Fieldbus Network Slave *** Slave *** Master C-BOX 00** CAB-60X CAB-60X CAB-60X CAB-60XX P.S.* CAB-60X BTK-6000 CAB-60X CAB-6XX Encoder**** Slave 5*** Slave *** Slave *** PWR-0 CAB-6XX Fieldbus Small Synchronized Network * P.S. (Presence Sensor) connected to External Trigger/PS input. ** C-BOX 00 modified to accept scanner power. *** The Slave scanners are Master/Slave models, which allow Lonworks network propagation. **** Encoder connected to IN/ENC input.

25 0 DS XX OSCILLATING MIRROR MODEL DS600 OSCILLATING MIRROR MODEL Figure A Laser Beam Output Window Oscillating mirror models are used when coverage of a large reading area is required, mainly in picket fence applications. The DS600 scanner mounts a dedicated optic head with integrated oscillating mirror driven by a linear motor. The speed, precision, repeatability, and reliability of this driving technology assure high level performance. The new oscillating mirror is completely software controlled and software programmable. The Genius software tool allows adjusting the linear motor speed (oscillating frequency) and the upper and lower limits of the oscillation by defining the top and bottom line limit angles. When the oscillating mirror is programmed to read barcode labels at very small angles, position the reader to assure at least 0 for the Skew angle (see DS600 Reference Manual). This angle refers to the most inclined or external laser line, so that all other laser lines assure more than 0 Skew. This avoids the direct reflection of the laser light emitted by the reader. Oscillating Mirror Skew Angle Otherwise, the scanner can be mounted at an angle of inclination of 7.5 in order to attain symmetrical deflection ranges Oscillating Mirror Reading Position In the above case, the zone where the scan line is perpendicular to the reflecting surface corresponds to a neutral zone at the center of the reading field.

26 DS600 OSCILLATING MIRROR MODEL The mirror can be deflected up to 0. Oscillation with respect to the output window median axis is asymmetrical (see figure below) Oscillating Mirror Maximum Aperture and Asymmetry By configuring the oscillating speed up to the maximum value of 9 Hz, raster emulation can be performed for reading fast moving objects. Hz Max. Aperture NOTE By limiting the raster width to the minimum necessary, the number of scans on the reading surface is increased. Oscillating angles are selected in software where the minimum and maximum angles correspond to.5 and The scanner can be tilted in order for the 7.5 software setting to correspond with the 0 horizontal plane Oscillating Mirror Extreme Angle Positions These models provide higher scanning speed (00 scans/sec) compared to standard models and the reading performance is not adversely effected by the oscillating mirror. The example represents the selection of an angle of +0 for the bottom line and an angle of +0 for the top line (see figure beside) Oscillating Mode

27 COMMON FEATURES COMMON FEATURES C-BOX 00 Pinout for DS600: The table below gives the pinout of the C-BOX 00 terminal block connectors. Use this pinout when the DS600 reader is connected in a network by means of the C-BOX 00: C-BOX 00 Terminal Block Connectors Power,, 5 VS,, 6 GND 7, 8 EARTH GROUND 0, 0 Reserved Inputs 7 EXT TRIG/PS A (polarity insensitive) for PS 8 EXT TRIG/PS B (polarity insensitive) for PS 9 IN /ENC A (polarity insensitive) for Encoder 0 IN /ENC B (polarity insensitive) for Encoder, IN A (polarity insensitive), IN A (polarity insensitive) 6 IN B/IN B Reference (polarity insensitive) Outputs OUT + OUT - OUT + OUT - 5 OUT A (polarity insensitive) 6 OUT B (polarity insensitive) Auxiliary Interface 5 TX AUX 7 RX AUX 8, 9 GND Main Interface RS RS85 Full-Duplex RS85 Half-Duplex, 5 TX TX 85+ RTX 85+, 6 RTS TX 85- RTX 85-7 RX * RX CTS * RX 85-0,, 9 SGND Main Isolated SGND Main Isolated SGND Main Isolated 9, RS85 Cable Shield RS85 Cable Shield 0 ma C.L. (with INT-0 only) see INT-0 instructions * Do not leave floating, see Reference Manual for connection details. 5

28 COMMON FEATURES Mechanical Installation: The DS600 reader can be positioned and installed in the best way possible as a result of the Step-A-Head TM feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position. The reading head and the decoder base can be rotated independently from each other allowing the installation even in the most critical locations. To rotate the head follow the given procedure:. detach the head from the base by unscrewing the four fixing screws; Head Screws. rotate the head in the desired position;. loosen but don't remove the two screws on top of the head;. affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half-way; 5. completely tighten the two screws on top of the head; 6. completely tighten the four fixing screws. Step-A-Head Feature The following diagrams give the overall dimensions of the reader standard model, oscillating mirror model and mounting bracket. They may be used for their installation: Fixing Screw () N N SLOTS 0.8 N SLOTS Ø. N Ø0.6 N = = = = mm inch 8.5 N SLOTS 0. N SLOTS Ø8.5 Ø0. mm inch 0. DS600 Overall Dimensions ST-7 Mounting Bracket Overall Dimensions Ø R R R mm inch R Ø mm inch DS600 Oscillating Mirror Model Overall Dimensions ST-0 Mounting Bracket Overall Dimensions 6

29 COMMON FEATURES Typical Installations: Standard Installation The DS600 scanner is mounted on the ST-7 06 mounting bracket which guarantees a built-in Skew angle (S in the figure below) of 6 with respect to the frame plane (typically the Skew angle should be between 0-0 ). This avoids the direct reflection of the laser light emitted by the scanner. Furthermore, the bracket guides allow adjusting the Tilt angle (T in the figure below, which is typically 0 ) for the best scanner orientation: T S Conveyor Direction 5 Skew Installation The DS600 scanner is mounted on the ST-0 90 mounting bracket. By adjusting the mounting bracket guides, reach 5 for the Skew angle (S in the figure below) to avoid the direct reflection of the laser light emitted by the scanner: 5 S ATTENTION If using the 5 Skew installation, the scanner reading performance is not guaranteed to match that measured for the standard installation with Skew angle between 0-0 (see reading diagram section). The ST-0 mounting bracket is an accessory of the DS600 standard model available in the US-60 kit (order no ). NOTE WARNING When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved. 7

30 COMMON FEATURES Adjustment: The DS600 provides a manual adjustment of the optics to optimize the reading performance by choosing the best focus between two extreme positions. The focus adjustment is continuous and not by step; thus, allowing an optimum adjustment around the selected position. The relative focus positions range from 0 to 00. The adjustment can be simply made through an external screw placed on the back of the optic HEAD and protected by a cap. The screw may be rotated either clockwise or counterclockwise in order to move the scanner internal lenses. In particular, a clockwise rotation causes a farther focus from the scanner, while a counterclockwise rotation causes a nearer focus to the scanner. An internal sensor tracks the exact laser beam focusing position allowing it to be shown on the reader display or through the Genius software program. WARNING Do not stare at the laser beam output window during this operation to avoid hazardous visible laser light. Refer to the following instructions when adjusting the focus: ) Remove the regulation screw protecting cap (see following Figure) positioned on the back of the optic Head; ) Press and hold both the (up arrow) and (down arrow) key for about seconds to enter the Main menu; ) Use the (up arrow) or (down arrow) key to select Test Mode item, then press the ENT (enter) key to confirm. The reader enters Test Mode; ) Press the ENT (enter) key to toggle between the graphical (default) and numerical visualization of the focus position; Display Visualization The first line of the display shows the read code and Good Read percentage. Possible suspending commas at the end of the code mean that the code is too long to be displayed. The second line of the display indicates the value of the focus position according to the table below. The indications Too Near or Too Far are represented for values outside the focus range. Graphical Visualization A ---^ where ^ indicates the focus position B N where N indicates that the focus position is Too Near C F where F indicates that the focus position is Too Far Numerical Visualization Fxxx where xxx ranges from 000 to 00 TooNear Fxxx* where xxx is greater than 00 CodeRead 00% ^ CodeRead 09% F0 Graphical Visualization Normal Visualization 5) Rotate the focus adjustment screw to reach the desired focus position. The display is refreshed with the new values; 6) Press the (up arrow) key to exit the Test Mode; To avoid breakage, do not use excessive force when rotating the focus adjustment screw. 8

31 COMMON FEATURES 7) Use the (up arrow) and (down arrow) key to select the Exit item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode. Adjustment Screw NOTE The reader display shows the focus position only when the laser beam is activated. It is possible to visualize the focus position and the reading percentage on the terminal tool provided by the Genius configuration program (see Genius Help On-Line for details). Reading Conditions: ANSI Grade B minimum 800 scans/sec The following tables describe the requirements for standard applications. Minimum Code Height for ACR Reading (mm) 5 0 Conveyor Speed (m/s) /5 Interleaved Code Resolution (mm) Ratio : Table Minimum Code Height for ACR Reading (mm) 5 0 Conveyor Speed (m/s) Code 9 Code Resolution (mm) Ratio :; Interdigit = Module Size Table 9

32 COMMON FEATURES Minimum Code Height for ACR Reading (mm) 5 0 Conveyor Speed (m/s) Code 8 Ean 8 Code Resolution (mm) Table Minimum Code Height for ACR Reading (mm) 5 0 Conveyor Speed (m/s) Codabar Code Resolution (mm) Ratio :; Interdigit = Module Size Table Minimum Code Height for ACR Reading (mm) 5 0 Conveyor Speed (m/s) EAN 8-, UPC-A Code Resolution (mm) Table 5 0

33 COMMON FEATURES Reading Diagrams: In the following reading diagrams (0,0) is the center of the laser beam output window. DS XX Resolution: 0.0 mm/8 mils (in) (cm) Position = 0 Position = CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = 0-0 Tilt angle = (in) (cm) DS XX Resolution: 0.0 mm/ mils (in) (cm) Position = 0 CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = Position = 0 Tilt angle = (in) -5-0 (cm) Position = 60

34 COMMON FEATURES Reading Diagrams: DS XX Resolution: 0.8 mm/5 mils (in) (cm) Position = CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = 0-0 Tilt angle = Position = Position = (in)(cm) DS XX Resolution: 0.50 mm/0 mils (in) (cm) Position = 00 CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = 0-0 Tilt angle = (in) (cm) Position = 60 Position = 0

35 COMMON FEATURES Reading Diagrams: DS XX (Oscillating Mirror) Resolution: 0.0 mm/8 mils (in) (cm) Position = 0 Position = CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = 0-0 Tilt angle = (in) (cm) DS XX (Oscillating Mirror) Resolution: 0.0 mm/ mils (in) (cm) 0 5 CONDITIONS Code = Interleaved /5 or Code Position = 0 Position = 0 PCS = 0.90 Pitch angle = 0 Skew angle = Tilt angle = (in) -5-0 (cm) Position = 60

36 COMMON FEATURES Reading Diagrams: DS XX (Oscillating Mirror) Resolution: 0.8 mm/5 mils (in) (cm) Position = CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = 0-0 Tilt angle = Position = Position = (in)(cm) DS XX (Oscillating Mirror) Resolution: 0.50 mm/0 mils (in) (cm) 60 Position = 00 CONDITIONS Code = Interleaved /5 or Code 9 PCS = 0.90 Pitch angle = 0 Skew angle = 0-0 Tilt angle = Position = Position = 0 - (in) -60 (cm)

37 COMMON FEATURES User Interface: 5 RS PC-side connections pin male connector 5-pin male connector Pin Name Pin Name RX RX TX TX 5 GND 7 GND 7 RTS RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS COM port connections. 5-pin D-sub female 9-pin D-sub female 0 TXAUX RXAUX RX TX PC GND 5 GND VS DS600 5 GND 9 VS 8 EXT TRIG A 9 EXT TRIG B Power Supply VS (5 0 VDC) Power GND Trigger Compliance: Laser Safety Figure A Laser Safety Label Figure B Warning and Device Class Label Identification Label 5

38 COMMON FEATURES Figure C Laser Safety Label The scanner is classified as a Class laser product according to EN regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius Help On-Line). AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE Laser Safety Label for Oscillating Mirror and Standard Models CAUTION-CLASS B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM LASER LIGHT DO NOT STARE INTO BEAM CLASS LASER PRODUCT MAX. OUTPUT RADIATION mw EMITTED WAVE LENGTH 60 ~ 680 nm EN6085-:00 Warning and Device Class Label DATALOGIC S.p.A. Via Candini, 00 LIPPO DI CALDERARA DI RENO (BO) ITALY MANUFACTURED VOLT Amp. JANUARY DC MODEL No. SERIAL No. N68 This product conforms to the applicable requirements of CFR 00 at the date of manufacture. Device Identification Label The laser diode used in this device is classified as a Class B laser product according to EN regulations and as a Class IIIb laser product according to CDRH regulations. Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (5 mw at 60 ~ 680 nm). Power Supply - This product is intended to be installed by Qualified Personnel only. - All DS600 Models: This device is intended to be supplied by a UL Listed Power Unit marked Class or LPS power source which supplies power directly to the scanner via the 5/6-pin connector. CE Compliance Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 6

39 DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l. Via S. Vitalino 00 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS600-XXX-XXX, Laser Scanner; e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/6/EEC EMC Directive e 9//EEC, 9/68/EEC emendamenti successivi and further amendments et ses successifs amendements und späteren Abänderungen y succesivas enmiendas 006/95/EC Low Voltage Directive Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 550 (Class A ITE), August 99: Amendment A (Class A ITE), October 000: EN , October 00: LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT ELECTROMAGNETIC COMPATIBILITY (EMC) PART 6-: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS EN , December 00: INFORMATION TECHNOLOGY EQUIPMENT SAFETY PART : GENERAL REQUIREMENTS EN 6085-, June 99: SAFETY OF LASER PRODUCTS Amendments A (996), A (00): PART : EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER'S GUIDE Lippo di Calderara, April nd, 007 Lorenzo Girotti Product & Process Quality Manager (Rev. I)

DS1100. LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1mW EMITTED WAVE LENGTH nm TO EN :2001

DS1100. LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1mW EMITTED WAVE LENGTH nm TO EN :2001 DS00 QUICK GUIDE General View: DS00 Laser Safety: The scanner is classified as a Class laser product according to EN 608- regulations and as a Class II laser product according to CDRH regulations. For

More information

DS6400 QUICK REFERENCE GUIDE

DS6400 QUICK REFERENCE GUIDE DS QUICK REFERENCE GUIDE CONTENTS DS-00-00 MASTER/SLAVE MODEL... DS-00-0 PROFIBUS MODEL...8 DS-00-0 ETHERNET MODEL...3 DS-00-05 DEVICENET MODEL...8 DS-05-0XX OSCILLATING MIRROR MODEL...3 COMMON FEATURES...5

More information

DX6400 QUICK REFERENCE GUIDE

DX6400 QUICK REFERENCE GUIDE DX6400 QUICK REFERENCE GUIDE CONTENTS DX6400-00-00 MASTER/SLAVE MODEL... DX6400-00-0 ETHERNET MODEL...9 COMMON FEATURES...5 NOTE For further details on product installation, see the complete Reference

More information

C-BOX 200. Installation Manual

C-BOX 200. Installation Manual C-BOX 200 Installation Manual C-BOX 200 INSTALLATION MANUAL dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX 200, active connection box DATALOGIC S.p.A., Via

More information

Matrix-2000 QUICK REFERENCE GUIDE

Matrix-2000 QUICK REFERENCE GUIDE Matrix-2000 QUICK REFERENCE GUIDE 1 5 9 10 11 4 3 2 6 7 8 1 2 3 4 Reading Window Positioning LED Keypad button Calibration LED Figure A 5 Communication LED 8 6 Main/Auxiliary Interface 9 7 Ethernet Interface

More information

IDENTIFICATION DS8100A ADVANTAGES APPLICATIONS

IDENTIFICATION DS8100A ADVANTAGES APPLICATIONS DS1A Configuration Sw Tool ACR technology PackTrack ASTRA Technology IDENTIFICATION APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems Airport baggage

More information

IDENTIFICATION DX8200A

IDENTIFICATION DX8200A Configuration SW Tool ACR technology PackTrack ASTRA technology IDENTIFICATION APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems Airport baggage sorting

More information

Touch 65/90 Pro CONTACT READERS

Touch 65/90 Pro CONTACT READERS Touch 65/90 Pro CONTACT READERS QUICK REFERENCE 820001260 (Rev. A) USING TOUCH PRO SERIES READERS scanning line trigger button Touch Pro readers scan barcodes on contact. All models have a hardware trigger

More information

DS2400N QUICK REFERENCE GUIDE

DS2400N QUICK REFERENCE GUIDE DS2400N QUICK REFERENCE GUIDE 4 5 6 2 3 7 1 11 10 9 8 Figure A 1 Warning and Device Class Labels 7 Laser Beam Output Window 2 "POWER ON" LED 8 "COM" LED 3 Mounting Holes 9 "STATUS" LED 4 "READY" LED 10

More information

DS2200. Reference Manual

DS2200. Reference Manual Reference Manual Datalogic Automation Srl Via S. Vitalino, 13 4001 - Lippo di Calderara di Reno Bologna - Italy Reference Manual Ed.: 08/008 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications

More information

DX8200A. Reference Manual

DX8200A. Reference Manual Reference Manual REFERENCE MANUAL DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy Reference Manual Ed.: 07/2006 ALL RIGHTS RESERVED Datalogic reserves the right to make

More information

DS2200. Reference Manual

DS2200. Reference Manual Reference Manual REFERENCE MANUAL DATALOGIC S.p.A. Via Candini 4001 - Lippo di Calderara di Reno Bologna - Italy Reference Manual Ed.: 4/006 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications

More information

DS4800 OM QUICK REFERENCE GUIDE

DS4800 OM QUICK REFERENCE GUIDE DS4800 OM QUICK REFERENCE GUIDE 4 3 5 2 1 6 Figure A 1 "POWER ON" LED 4 Display 2 Focus Adjustment 5 Laser Beam Output Window 3 Indicator LEDs 6 Push Button NOTE This manual illustrates a Stand Alone application.

More information

DS1100. Reference Manual. Phone: Fax: Web: -

DS1100. Reference Manual. Phone: Fax: Web:  - Reference Manual Datalogic Automation Srl Via S. Vitalino, 13 40012 - Lippo di Calderara di Reno Bologna - Italy Reference Manual Ed.: 07/2008 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications

More information

CBX500 INSTALLATION MANUAL

CBX500 INSTALLATION MANUAL CBX500 INSTALLATION MANUAL 1 2 3 4 5 Figure A 1 2 3 Indicator LEDs Cover Screws (4) Fieldbus Interface Panel 4 5 Compression Connectors (5) 25-pin Device Connector 6 7 8 9 10 5 11 4 3 12 13 2 1 14 1 Figure

More information

IDENTIFICATION DS4800 APPLICATIONS ADVANTAGES

IDENTIFICATION DS4800 APPLICATIONS ADVANTAGES Enhanced Connectivity Ease of use Configuration SW Tool ACR4 technology Smart focus adjustment IDENTIFICATION APPLICATIONS Automated warehousing Reading on pallets Picking systems Automated shop floor

More information

Matrix 400 QUICK REFERENCE GUIDE

Matrix 400 QUICK REFERENCE GUIDE Matrix 400 QUICK REFERENCE GUIDE 1 2 3 4 5 2 10 7 8 2 9 Figure A 6 1 Device Class Label 6 HMI X-PRESS Interface 2 Mounting Holes (12) 7 "POWER ON" LED 3 Lens Cover 8 Power - Serial Interfaces - I/O Connector

More information

DS2100N. Reference Manual

DS2100N. Reference Manual DS2100N Reference Manual Datalogic Automation Srl Via S. Vitalino, 13 40012 - Lippo di Calderara di Reno Bologna - Italy DS2100N Reference Manual Ed.: 03/2008 ALL RIGHTS RESERVED Datalogic reserves the

More information

DS4300 INSTALLATION MANUAL

DS4300 INSTALLATION MANUAL INSTALLATION MANUAL We DATALOGIC S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product -XXXX, Laser Scanner and all its models to which

More information

CBX800 INSTALLATION MANUAL

CBX800 INSTALLATION MANUAL CBX800 INSTALLATION MANUAL 1 2 3 4 5 Figure A 1 2 3 Indicator LEDs Cover Screws (4) Host Interface Module Panel 4 5 Compression Connectors (5) 25-pin Device Connector NOTE For a complete Gateway configuration

More information

DS2100N QUICK REFERENCE GUIDE

DS2100N QUICK REFERENCE GUIDE DS00N QUICK REFERENCE GUIDE 4 5 6 3 7 0 9 8 Figure A Warning and Device Class Labels 7 Laser Beam Output Window "POWER ON" LED 8 "COM" LED 3 Mounting Holes 9 "STATUS" LED 4 "READY" LED 0 Push Button 5

More information

DS2400N QUICK REFERENCE GUIDE

DS2400N QUICK REFERENCE GUIDE DS2400N QUICK REFERENCE GUIDE 11 4 5 6 3 7 2 1 10 9 8 Figure A 1 Warning and Device Class Labels 7 Laser Beam Output Window 2 "POWER ON" LED 8 "COM" LED 3 Mounting Holes 9 "STATUS" LED 4 "READY" LED 10

More information

DS41. Installation Manual

DS41. Installation Manual Installation Manual INSTALLATION MANUAL We DATALOGIC S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product -XX, Laser Scanner and all its

More information

Heron D130 READERS QUICK REFERENCE

Heron D130 READERS QUICK REFERENCE Heron D130 READERS QUICK REFERENCE 820001203 (Rev. D) UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to : www.datalogic.com

More information

Formula USER MANUAL * * ENGLISH

Formula USER MANUAL * * ENGLISH Formula 630 - USER MANUAL *200023993120* ENGLISH DATALOGIC S.p.A. Secondary Unit - IDWare Division Via Guglielmo Marconi, 161-31021 Mogliano Veneto (TV) - Italy Tel. +39 (041) 5986511 - Fax +39 (041) 5986550

More information

FACTORY AUTOMATION MANUAL VB14N BARCODESCANNER

FACTORY AUTOMATION MANUAL VB14N BARCODESCANNER FACTORY AUTOMATION MANUAL VB14N BARCODESCANNER With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541) Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or

More information

FACTORY AUTOMATION MANUAL BARCODE SCANNER VB14A

FACTORY AUTOMATION MANUAL BARCODE SCANNER VB14A FACTORY AUTOMATION MANUAL BARCODE SCANNER VB14A VB14A With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

Formula USER MANUAL * * ENGLISH

Formula USER MANUAL * * ENGLISH Formula 8500 - USER MANUAL *200175985020* ENGLISH Datalogic S.p.A. Via Guglielmo Marconi 161-31021 Mogliano Veneto (TV) - Italy Tel. (int+) 041-598 6511 - Fax (int+) 041-598 6550 Formula 8500 - USER MANUAL

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

REFERENCE MANUAL > DS2400N. Phone: Fax: Web:

REFERENCE MANUAL > DS2400N. Phone: Fax: Web: REFERENCE MANUAL > DS2400N Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy DS2400N Reference Manual Ed.: 11/2013 2007 2013 Datalogic Automation S.r.l. ALL RIGHTS RESERVED.

More information

A30 QuickStart Guide. Publication # (Rev D)

A30 QuickStart Guide. Publication # (Rev D) A30 QuickStart Guide Publication # 821002024 (Rev D) DATALOGIC S.r.l. Via S. Vitalino 13-40012 Calderara di Reno - Italy www.datalogic.com A30 QuickStart Guide Edited: 7-Jun-17 2013-2017 Datalogic S.p.A.

More information

DS1500. Reference Manual

DS1500. Reference Manual Reference Manual Datalogic Automation S.r.l. Via Lavino, 65 40050 - Monte S. Pietro Bologna - Italy Reference Manual Ed.: 07/011 006 011 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the

More information

Matrix 300 QUICK REFERENCE GUIDE. Bracket Mounting Holes (4) Good Read LED (green) Lens Cover HMI X-PRESS Interface. Lens Internal Illuminator

Matrix 300 QUICK REFERENCE GUIDE. Bracket Mounting Holes (4) Good Read LED (green) Lens Cover HMI X-PRESS Interface. Lens Internal Illuminator 1 2 2 Matrix 300 QUICK REFERENCE GUIDE 1 Device Class Label 3 4 5 2 Bracket Mounting Holes (4) 6 3 Good Read LED (green) 4 Lens Cover 5 HMI X-PRESS Interface 6 7 Lens Internal Illuminator 11 13 12 8 9

More information

AUTOMOTIVE HEALTHCARE - PHARMACEUTICAL FOOD - BEVERAGE - TOBACCO ELECTRONICS & SOLAR GENERAL MANUFACTURING TRANSPORTATION & LOGISTICS

AUTOMOTIVE HEALTHCARE - PHARMACEUTICAL FOOD - BEVERAGE - TOBACCO ELECTRONICS & SOLAR GENERAL MANUFACTURING TRANSPORTATION & LOGISTICS D A T A L O G I C A U T O M A T I O N F O R I N D U S T R I A L A U T O M A T I O N Datalogic Automation is one of the worldwide leading producers of automatic identification, detection and marking solutions

More information

CBX800 INSTALLATION MANUAL

CBX800 INSTALLATION MANUAL CBX800 INSTALLATION MANUAL 1 2 3 4 5 Figure A 1 2 3 Indicator LEDs Cover Screws (4) Host Interface Module Panel 4 5 Compression Connectors (5) 25-pin Device Connector NOTE For a complete Gateway configuration

More information

CBX800 INSTALLATION MANUAL

CBX800 INSTALLATION MANUAL CBX800 INSTALLATION MANUAL 1 2 3 4 5 Figure A 1 2 3 Indicator LEDs Cover Screws (4) Host Interface Module Panel 4 5 Compression Connectors (5) 25-pin Device Connector NOTE For a complete Gateway configuration

More information

SC4000. Reference Manual

SC4000. Reference Manual SC4000 Reference Manual Datalogic Automation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy SC4000 ID-NET TM Controller Reference Manual Ed.: 06/2009 2009 Datalogic Automation

More information

FACTORY AUTOMATION MANUAL CBX800

FACTORY AUTOMATION MANUAL CBX800 FACTORY AUTOMATION MANUAL CBX800 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical

More information

A30 QuickStart Guide. Publication # (Rev C)

A30 QuickStart Guide. Publication # (Rev C) A30 QuickStart Guide Publication # 821002023 (Rev C) Datalogic Automation, Inc. 5775 West Old Shakopee Rd Suite 160 Bloomington MN 55437 USA A30 QuickStart Guide Edited: 26-Jun-15 2013-2015 Datalogic Automation,

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

FACTORY AUTOMATION. PROGRAMMING SOFTWARE VisoSetup

FACTORY AUTOMATION. PROGRAMMING SOFTWARE VisoSetup FACTORY AUTOMATION PROGRAMMING SOFTWARE VisoSetup VISOSETUP PROGRAMMING To suit your specific application, the Standard Application program may be configured from a PC using the VisoSetup interface utility

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

MATRIX 410. Reference Manual

MATRIX 410. Reference Manual MATRIX 410 Reference Manual Datalogic Automation S.r.l. Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy Matrix 410 Reference Manual Ed.: 10/2010 2007 2010 Datalogic Automation S.r.l. ALL RIGHTS

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression S3Z Advanced line of miniature Asian style of photoelectric sensors 5-25 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 15 m through beam Standard 3-wire output

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) XPSMCMx Fieldbus Expansion Modules EAV8283001 12/2014 XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) 12/2014 EAV8283001.00 www.schneider-electric.com The information provided

More information

F3EM Measuring lightcurtain in robust aluminium housing

F3EM Measuring lightcurtain in robust aluminium housing Measuring lightcurtain in robust aluminium housing F3EM Measuring lightcurtain in robust aluminium housing The F3EM provides easy to install and set up height and profile measurement. The analog output

More information

REFERENCE MANUAL > DX8210. Omnidirectional Barcode Scanner

REFERENCE MANUAL > DX8210. Omnidirectional Barcode Scanner REFERENCE MANUAL > DX8210 Omnidirectional Barcode Scanner Datalogic Automation Srl Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy DX8210 Omnidirectional Barcode Scanner Reference Manual Ed.: 8/2016

More information

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more EN LZR - U920/-U92 LASER MEASUREMENT DEVICE with bidirectional bus communication User s Guide for product version 0500 and more 2 LASER MEASUREMENT DEVICE Other use of the device is outside the permitted

More information

Modular controllers CECX

Modular controllers CECX Key features At a glance Versatile The controller is functionally designed as a master and motion controller. It is a powerful control unit that can Economical simultaneously execute both comprehensive

More information

T4x-Series Hardware Guide. Publication # (Rev B)

T4x-Series Hardware Guide. Publication # (Rev B) T4x-Series Hardware Guide Publication # 843-0149 (Rev B) Datalogic Automation, Inc. 5775 West Old Shakopee Rd Suite 160 Bloomington MN 55437 USA T4x-Series Hardware Guide Edited: 02/2014 2014 Datalogic

More information

HEC. General Operating, Maintenance and Installation Manual

HEC. General Operating, Maintenance and Installation Manual HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version

More information

Online data sheet. V2D654R-MEWKA6 Lector65x IMAGE-BASED CODE READERS

Online data sheet. V2D654R-MEWKA6 Lector65x IMAGE-BASED CODE READERS Online data sheet V2D654R-MEWKA6 Lector65x A B C D E F Ordering information Type Part no. V2D654R-MEWKA6 1068680 Other models and accessories www.sick.com/lector65x H I J K L M N O P Q R S T Detailed technical

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

Diagnostics (Physical)

Diagnostics (Physical) DeviceNet Spanner Rugged, Fully Potted Stations IP 67 Protection Communicate Between s Connect Two DeviceNet Networks FDN-DN1 Electrical Operating Current: 125 ma from segment A, 30 ma from segment B Power

More information

TM221CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet Characteristics controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Jan 6, 2019 Modicon M221 Logic controller 100...240 V AC Discrete input number

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

Fixed mount CCD bar code reader NFT Specification Ver. 1.0

Fixed mount CCD bar code reader NFT Specification Ver. 1.0 Fixed mount CCD bar code reader NFT-2100 Specification Ver. 1.0 Version Control number : Model : SS05011 NFT-2100 Version Date Revisions Description Ver 1.0 2005/06/09 - First registration 1. About this

More information

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual 5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed. Assembly Instructions scancontrol 2600/2650/2900/2950 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply

More information

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10

More information

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2. Product datasheet Characteristics TM241CEC24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Discrete output type Discrete output number Discrete output

More information

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21- Innovation, Quality, Performance 21- imove 50SR User Guide Professional Entertainment Technology EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following

More information

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression S3Z Advanced line of miniature Asian style of photoelectric sensors 5-25 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 15 m through beam Standard 3-wire output

More information

Online data sheet. V2D654R-MEBHF6 for Systems Lector65x IMAGE-BASED CODE READERS

Online data sheet. V2D654R-MEBHF6 for Systems Lector65x IMAGE-BASED CODE READERS Online data sheet V2D654R-MEBHF6 for Systems Lector65x A B C D E F Ordering information Type Part no. V2D654R-MEBHF6 for Systems 1070743 Other models and accessories www.sick.com/lector65x H I J K L M

More information

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19- SAMURAI SCAN 50 LED-SC50D Innovation, Quality, Performance User Guide Professional Entertainment Technology 19- EC Declaration of Conformity We declare that our products (lighting equipments) comply with

More information

Rotary Measurement Technology Absolute Encoders, Singleturn

Rotary Measurement Technology Absolute Encoders, Singleturn -40 to 80 C IP Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable

More information

Mounting possibilities (threaded M5)

Mounting possibilities (threaded M5) L-LAS Series L-LAS-LT-55-RA-HS (High Speed) - Operates in an angle of total reflection (distance measurement) - Suitable for high-glossy objects (e.g. glass) - Line laser

More information

Assembly Instructions scancontrol 2700/2750 (500)

Assembly Instructions scancontrol 2700/2750 (500) Assembly Instructions scancontrol 2700/2750 (500) 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply

More information

MATRIX 210. Reference Manual

MATRIX 210. Reference Manual MATRIX 210 Reference Manual Datalogic Automation S.r.l. Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy Matrix 210 Reference Manual Ed.: 01/2014 2011-2014 Datalogic Automation S.r.l. ALL RIGHTS

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

SAFETY & MESUREMENT SERIE SG-BODY BIG

SAFETY & MESUREMENT SERIE SG-BODY BIG safety BODY PROTECTION LIGHT CURTAINS SERIE SG-BODY BIG reflector The new SG BODY BIG safety light curtain series thanks to its new housing together with the innovative design optical-electronic platform

More information

TCF-142-RM Series Hardware Installation Guide

TCF-142-RM Series Hardware Installation Guide TCF-142-RM Series Hardware Installation Guide Third Edition, March 2015 2015 Moxa Inc. All rights reserved. P/N: 1802001420622 *1802001420622* Overview Introduction The TCF-142-RM series fiber converters

More information

LaserLyte-Flex Red & Green Alignment System

LaserLyte-Flex Red & Green Alignment System LaserLyte-Flex Red & Green Alignment System LaserLyte-Flex The LaserLyte-Flex is an entry-level laser alignment system. It uses interchangeable optics and a semiconductor laser diode to project a highly

More information

Perle Gigabit Media Converter Module. Installation Guide P/N

Perle Gigabit Media Converter Module. Installation Guide P/N Perle Gigabit Media Converter Module Installation Guide Unmanaged Managed C-1000-M2SC05 C-1000-M2LC05 C-1000-S2LC10 C-1000-S2SC10 C-1000-S2LC40 C-1000-S2SC70 C-1000-S2LC70 C-1000-S1SC10U C-1000-S1SC10D

More information

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories 2D-code hand-held scanner Dimensioned drawing 4-14 V DC We reserve the right to make changes BP_IT4600_4800_GB.fm Part No. 501 06667! Hand-held scanner for Data-Matrix Codes and Bar Codes! Large reading

More information

TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN Characteristics controller M251 Ethernet CAN Price* : 278.88 GBP Main Range of product Product or component type [Us] rated supply voltage Complementary Number of I/O expansion module Supply voltage limits

More information

Inclination sensors 1-dimensional, measuring range

Inclination sensors 1-dimensional, measuring range Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R

More information

TM241C40U controller M IO transistor NPN

TM241C40U controller M IO transistor NPN Characteristics controller M241 40 IO transistor NPN Main Range of product Product or component type [Us] rated supply voltage 15/12/2018 Modicon M241 Logic controller 24 V DC Discrete input number 24

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measurement Technology Absolute Encoders, Multiturn -40 to 80 C IP Mechanical drive Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection

More information

MATRIX 450. Reference Manual

MATRIX 450. Reference Manual MATRIX 450 Reference Manual Datalogic Automation S.r.l. Via Lavino, 265 40050 - Monte S. Pietro Bologna - Italy Matrix 450 Reference Manual Ed.: 02/2013 2012-2013 Datalogic Automation S.r.l. ALL RIGHTS

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

270 MHz Control Modules

270 MHz Control Modules 2400 / 2420 / 2450 Performance Drives A D D E N D U M 270 MHz Control Modules Notices 2000.40(A2) 01 11/08 Copyright 2002-2008 by Unico, Incorporated. All rights reserved. No part of this publication may

More information

PHOTOSWITCH Distance Measurement Sensor

PHOTOSWITCH Distance Measurement Sensor Installation Instructions Original Instructions Catalog Numbers 45DMS-B8LAT-D4, 45DMS-B8LGT-D5 Topic Description Save these instructions for future use. Description Features Sensor Configuration Precision

More information

AC 800M for Compact Product Suite Outline of all modules

AC 800M for Compact Product Suite Outline of all modules DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet Characteristics controller M241 40 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage 18 Nov, 2018 Modicon M241 Logic controller 24 V DC Discrete input

More information

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24U controller M IO transistor NPN Ethernet Characteristics controller M241 24 IO transistor NPN Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 24 V DC Discrete input

More information

Installation and operation manual EPIC

Installation and operation manual EPIC Installation and operation manual EPIC Table of contents Cap. Pag. 1 EPIC presentation 4 2 Safety warnings 4 3 Installation 4 4 Technical characteristics 4 5 Electrical connections 5 6 Mains protection

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Characteristics controller M241 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 100...240 V AC Discrete input number

More information

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg. Safety Selection Guide... 430 Type 2 SG2 Series (Basic & Extended Models)... 431 Type 4 SG4 Series... 435 Mounting Brackets and Accessories... 439 www.idec.com/safety Light Curtains Overview XW Series

More information

TM221M16TG controller M IO transistor PNP spring

TM221M16TG controller M IO transistor PNP spring Characteristics controller M221 16 IO transistor PNP spring Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information