1 Dürr Dental VistaCam CL.iX Installation and Operating Instructions / /10

2 2 2009/10

3 Contents Important information 1. General Conformity acceptance procedure General notes Appliance disposal Notes concerning medical appliances MPG Notes concerning electro-magnetic compatibility Correct usage Incorrect usage Using peripheral devices 5 2. Safety General safety notes Electrical safety notes 5 3. Warning and Symbols Model identification plate 6 4. Delivery Contents Special accessories Disposable materials 7 5. Technical data 7 6. Functional diagram 8 7. Functional description 9 Installation 8. Set-up Room for set-up Set up options Installation of handpiece holder (optional) Electrical Connections Connection to base station Connect Commissioning LEDs at base station Channel settings Testing 14 Use of the Appliance 11. Operation Important information concerning the handpiece Using hygienic protective covers Switching VistaCam CL.iX on or off Instructions for using IFC Optic Using distance spacer (optional) Taking images Care of handpiece Disinfection and Cleaning Cleaning the optical lens Cleaning and disinfecting handpiece and other accessories Cleaning, disinfection and sterilisation of distance spacers Maintenance Changing the battery pack Battery care 22 Trouble-shooting 14. Tips for Operators and Service Technician /10 3

4 1. General Important information 1.1 Conformity acceptance procedure This product has, in accordance with the European Union directive 93/42/EWG, been checked for conformity and has been found to fulfill all the requirements of these regulations. 1.2 General notes These Installation and Operating Instructions form an integral part of the unit. They must be kept close to the unit at all times. Precise observance of these instructions is a precondition for use of the unit for the intended purpose and for its correct operation. New personnel must be made aware of the contents, and they should be passed on to future operating staff. Safety for the operator as well as trouble-free operation of the unit are only ensured if use is made of original equipment parts. In addition, only those accessories may be used which are specifically mentioned in the Installation and Operating Instructions or have been authorised by Dürr Dental. If other accessories are used with this appliance, Dürr Dental cannot guarantee safe operation or proper functioning. No liability on the part of the manufacturer will be accepted in the case that damage arises through the use of non-approved accessories. Dürr Dental are only responsible for the equipment with regard to safety, reliability and proper functioning where assembly, resettings, changes or modifications, extensions and repairs have been carried out by Dürr Dental or an agency authorized by Dürr Dental and if the equipment is used in conformity with the Installation and Operating Instructions. These Installation and Operating Instructions conform to the relevant version of the equipment and the underlying safety standards valid at the time of going to press. All switches, processes, trade marks, software programs and appliances named in this document are registered names. The translation of these Installation and Operating Instructions has been carried out in good faith. Dürr Dental will not accept any claims arising from incorrect translation. The enclosed German version of these Installation and Operating Instructions is the final reference - in case of doubt contact the manufacturer or their agent. Any reprinting of the technical documentation, in whole or in part, is subject to prior approval of Dürr Dental being given in writing. Retain the packaging for possible return of the product to the manufacturers. Only the original packaging provides adequate protection during transport of the unit. Should return of the product to the manufacturers be necessary during the guarantee period, Dürr Dental accepts no responsibility for damage occurring during transport where the original packaging was not used! 1.3 Appliance disposal The EU-directive 2002/96/EG - WEEE (Waste Electric and Electronic Equipment) of 27th January 2003 and the current version as adopted by national law states that dental products are covered by this above directive and, within the European Union, must be disposed of according to special waste disposal procedures. If you have any questions concerning the correct way of disposing of this product please contact Dürr Dental or your dental dealer who will be happy to help. 1.4 Notes concerning medical appliances MPG This product is a technical medical appliance and may only be operated by staff who have been specifically trained and instructed how to use it. 1.5 Notes concerning electro-magnetic compatibility Electrical medical appliances are covered by special regulations concerning electro-magnetic compatibility and must be installed while observing all EMC relevant rules and regulations. Portable and mobile HF-communications appliances can interfere with medical electrical appliances. The VistaCam CL.iX should not be operated in the vicinity of other appliances or placed on or under other appliances. When the VistaCam CL.iX is nonetheless operated in the vicinity of /10

5 other appliances the function of the unit must be extra carefully monitored to ensure that it is working as it should be. Detailed information concerning electro-magnetic compatibility of Dürr Dental appliances is set out in our brochure /30 which can be ordered or downloaded from the internet at: Correct usage The wireless camera system "Dürr VistaCam CL.iX" is a radio-controlled camera with manual release. The radio-controlled camera is expressly designed for producing intra and extra-oral images in dental-medical surgeries and clinics. 1.7 Incorrect usage Any use of this appliance above and beyond that laid down in the Installation and Operating Instructions is deemed to be incorrect usage. The manufacturer cannot be held liable for any damage resulting from incorrect usage. The operator will be held liable and bears all risks. 1.8 Using peripheral devices Peripheral appliances (computer, monitor, printer) may only be connected to this unit where they fulfill all the requirements of standard IEC ( ). Thie computer system must be placed outside of the vicinity of the patients (1.5 m from patient treatment zone). If this is not possible, then the PC system must be set up according to the instructions laid down under IEC ( ). 2. Safety 2.1 General safety notes This appliance has been designed and constructed by Dürr Dental so that correct usage of the appliance is virtually free of any possible injury or danger. In spite of this, we feel it is our duty to mention the following safety measures in order to prevent any possible danger. When using this appliance all local and relevant regulations must be observed! Converting or modifying the appliance in any way is strictly prohibited. In such cases, any and all guarantees immediately become invalid. The operation of modified appliances can be punishable by law. In the interests of troublefree operation the operator is responsible for observing these regulations. Before every use the operator must check the functional safety and the condition of the appliance. The operator must be knowledgeable in the operation of the appliance. The product is not designed to be used in medical treatment areas where there exists the danger of explosion. Areas where explosions could occur are those where flammable anesthetic material, skin cleansers, oxygen and skin disinfectants are present. This appliance is not to be used in areas where the atmosphere could cause fire. 2.2 Electrical safety notes The appliance may only be connected to an earthed safety socket. Do not use any multi-socket power outlet which can be changed on-site. The usage of such units could lead to the current to ground being exceeded. Before connecting the appliance, check carefully that the supply voltage and the supply frequency given on the appliance are compatible with the local power supply. Check the appliance and the power supply cables for possible damage before switching on. Damaged cables, plugs and sockets must be replaced before use. Never touch open supply outlets and patients simultaneously. When working on or working with this appliance observe the electrical safety procedures prescribed. 2009/10 5

6 3. Warning and Symbols In the Installation and Operating Instructions use is made of the following terms or symbols to denote information of special importance: Information and/or mandatory regulations or prohibitions for the prevention of personal injury or substantial property damage Special information regarding the economical use of the equipment and other information Only to be used once Symbols on the VistaCam CL.iX Macro Intraoral Extraoral 3.1 Model identification plate The model identification plate can be found to the side by the USB-connector. The model identification plate bears the following signs, symbols or information: CE-labeling Please observe instructions in accompanying documentation Dispose of correctly according to EUdirective (2002/96/EG - WEEE) 1 REF SN Order number Serial number /10

7 4. Delivery Contents VistaCam CL.iX, complete Accessories, complete Handpiece 2,4 Hz Handpiece 5,8 Hz Base station 2,4 Hz Base station 5,8 Hz Power unit V, Hz Mains cable 2x0, USB 2.0 connection cable (1.8 m) Mounting for Base Unit Distance spacer for mounting (2 x) Rubber pads (3 x) Velcro tape 38x330 mm Seal 25x460 mm Dowel S6 (2 x) Wood screws (2 x) Distance spacers (2 x) Pressure sensitive ring (2 x) Prism holder Screws M 4x12 (2 pieces) Distance spacer, short (5 x) Distance spacer, long (5 x) Hygienic protective covers (20 x) FD 350 disinfectant wipes LemonCDF350L1240 DBSWIN Video module FC Installation and Operating Instructions /.. Installation and configuration instructions / Special accessories The following parts are not included in the original Delivery Contents. Please order as required! Optics cleaning set Handpiece holder, free standing with foot TFT Monitor 17" Radio foot-pedal set USB Foot pedal USB cable Disposable materials Hygienic protective covers (500 x) Cleaning set for Optic FD 350 Disinfectant wipes CDF350CO140 Distance spacer, short (5 x) Distance spacer, long (5 x) Pressure sensitive ring Rechargeable battery pack for VistaCam CL.iX Battery-operated radio/operated foot pedal Technical data Electrical Values and Connections Voltage (V) Frequency(Hz)50-60 Signal output USB 2.0 Dimensions (mm) Base station (W x H x D)83 x 115 x 38 Handpiece (length / diameter)213 / 27 Weight (g) Base station 180 handpiece 150 Lighting - 6 LEDs with light collecting lens Battery operation (min) Operating time with freshly charged battery pack ca. 45 Batteries VistaCam CL.iX: NiMH battery pack Radio-controlled foot pedal: Lithium button cell, Li CR2450 System characteristics Colour systempal Automatic brightness control White balance factory set to (K) 3400 Temperature ranges Appliance in operation ( C) +10 to +40 Storage and transport ( C) -15 to +60 Relative humidity Appliance in operation (%) 20 - max.75 Storage and transport (%)max. 90 Air pressure Appliance in operation (hpa) Storage and transport (C)700 to Camera electronics Image sensor 1/4" Color Interline Transfer CCD Pixels PAL Effective pixels (PC) YUV 720 horizontal x 576 vertical IFC (Iris Focus Control) Optic Integrated lighting, freely variable focus using the adjustable ring with three markings: 1) Magnifying glass: Macro 2) 2 Teeth: Intraoral 3) Face: Extraoral Max. magnification 100 Fuse type IP20 Protection class II, Operational parts Type BF 2009/10 7

8 6. Functional diagram 1a 1c 1 1a 9a 9b 9c 9 1b 2 2a b 3a 6 6a (1) VistaCam CLiX handpiece (1a) Manual release (1b) Handpiece rechargeable battery pack (1c) ON / OFF switch (2) Free-standing handpiece holder (optional) (2a) Handpiece holder mounted on base station (optional) (3) Cable to foot pedal unit (3a) Cable operated foot pedal switch unit (optional) (3b) Radio operated foot pedal switch unit (optional) (4) PC (5) USB 2.0 connection cable (6) battery charge station (6a) LED, green (7) Power unit with connection cable (8) Mains cable (9) Basis station (9a) LED, green (9b) LED, blue (9c) LED, yellow /10

9 7. Functional description The Dürr VistaCam CL.iX wireless controlled camera system consists of a base station (8), a handpiece (1) with IFC-Optic (Iris Focus Control) and the handpiece holder (2). If desired either a cable-operated foot pedal (3a), or a radio-operated foot pedal (3b) can be connected to the system. The handpiece is connected via radio with the base station. The base station is supplied with power via mains cable and power unit. A USB 2.0 cable provides the connection between base station and PC. The handpiece switches on automatically as soon as it is removed from its handpiece holder or from the battery charger. Additionally, the handpiece can be operated using the controls at the lower end of the handpiece. Within the handpiece there are 6 white LEDs, which provide sufficient lighting. The special IFC- Optic allows macro, intraoral and extraoral images to be prepared. Within the macro and intraoral ranges the IFC Optic provides a high depth of field. In the extraoral range the IFC Optic has a high light intensity. The image is picked up by the IFC Optic and electronically converted into a video signal. The video signal is then transmitted by radio signal to the base station. The base station now digitalises the image data and transmits this data directly to the PC via the USB 2.0 connection. using the 360 all round manual release manual release its Sensitive Control means images on the monitor can be switched between Live Mode to Freeze Mode, saved or overwritten (depending on software). The manual release functions using a pressure sensitive ring switch and can be operated with the camera at any angle whatever simply by applying pressure with a finger. Operating the manual release causes a short, light vibration and an acoustic signal can be heard at the base station. The base station has several LEDs which serve the following functions: green LED blue LED yellow LED camera is ready there is a radio signal connection between camera (switched on) and base station. transmission of data between camera and PC, e.g. when live images are seen on the monitor. Diagnostics can be followed up using the digital image editing system DBSWIN. 2009/10 9

10 Set-up Installation Ensure that the electrical socket into which the unit is plugged is easily accessible. Danger of a short circuit Do not set the VistaCam CL.iX up in the vicinity of a wash basin, sink or spittoon. Prevent spray water from coming near the camera or the electrical connections. 8.1 Room for set-up The room temperature must not fall below + 10 C in winter and in summer must not rise above + 40 C. 8.2 Set up options Wall mounting Use screws, dowels and the two distance spacers to mount the holder (10) onto a wall. Place the base station into its holder. Pipe mounting The holder (10) can be fixed as required to any available vertical or horizontal pipe (11) using the mounting strap (12). Place the base station into its holder. Table set-up The base station can be set up on a flat surface, e.g. on a table. Stick the rubber pads (13) supplied onto the rear side of the base station /10

11 Installation of handpiece holder (optional) The handpiece holder (2) can be mounted directly onto the base station or any suitable position in the vicinity of the VistaCam CL.iX. (Length of camera cable 2 m.) Use installation set, order number Details of how to attach the handpiece holder are included with the installatio set. Please read these carefully. Damaging the VistaCam CL.iX The handpiece can easily fall out and become damaged if the handpiece holder is set up incorrectly. Position the handpiece holder so that the handpiece can not possibly fall out Electrical Connections Observe requirements IEC ( ; VDE 0750 Section 1-1) on connection to the monitor. If you have any questions concerning suitable peripheral appliances, please consult Dürr Dental or your local dental supply depot Connection to base station 7-1 (9) Base station (7-1) Power supply mains connection, 7.5 V DC (external power unit) 3-1 (3-1) Foot pedal 5-1 (5-1) Video USB Connect The USB 2.0 connection cable (5) should only be actually connected during installation to the PC (not before), see section 10.1 All other cables can be connected as shwon in figs. 8 and 9. (3) foot pedal cable (optional) (5) USB 2.0 connection cable to base station (7) power unit with connection cable (8) mains cable /10 11

12 1 1b 10. Commissioning Do not put the appliance into operation immediately. The appliance should be allowed to reach room temperature. Temperature differences can lead to the build up of condensation which could destroy the electronics when the unit is switched on. The appliance must not be used in any way that gives concern regarding safety! The appliance may only be operated in a safe and functional condition. 10 Always handle the handpiece (1) carefully. It must not be allowed to fall. Scratches or dirt on the optical lens will lead to a high loss in image quality a 1 1c Place the rechargeable battery pack (1b) into the handpiece (1). Place the handpiece into the battery recharging unit (6). green LED (6a) blinks green LED (6a) lit fast charging mode running. battery charged unit ready battery is fully charged after ca. 1.5 h. Switch on PC Switch on monitor. Install software. Refer to "Installation and Configuration of VistaCam CL.iX with manual release", order number /01 Open DBSWIN Remove the handpiece from the battery charger unit (6). The VistaCam CL.iX switches on automatically. Select Video-mode. The live image is now displayed on the monitor. The image is presented in normal viewing mode. The mirror inversion mode can be chosen if reverse imaging is required by activating the monitor imaging as follows: Press switch (1c) 2 x briefly /10

13 9a 9b 9c LEDs at base station green LED (9a) lit blue LED (9b) lit yellow LED (9c) lit camera ready radio signal connection established between camera (switched on) and base station. transmission of data between camera and PC, e.g. when live images are seen on the monitor. The green and yellow LEDs light even if the camera is switched off Channel settings Where more than one treatment unit (i.e. chair) is served or in the event of radio transmission interference channel setting is possible at the handpiece, in DBSWIN and either the cable or the radio-operated foot pedal (optional). The channel setting in DBSWIN must, however, be identical to that at the handpiece DBSWIN channel setting open DBSWIN - folow the display Option - Configuration - Video - Video set up / Settings / Base station Under "Camera Channel" (11) it is possible to set the channel required from 1-5. Choose the same channel on the handpiece, see section Place a tick (check) in the box "Camera Manual Release" (12). 1d 1 1c Handpiece channel setting Switch off handpiece (1) at switch (1c). Press down the switch (1) until the LEDs (1d) blink: 1x blink = channel 1 2x blink = channel 2, 3x blink = channel 3, etc. As soon as the blue LED (9b) at the base station (9) lights then the correct channel has been chosen /10 13

14 Channel selection for cable or radiooperated foot pedal (optional) Under "Foot Pedal Channel" (13) it is possible to set the channel required from 1-8. Place a tick (check) in the box "Radio-operated Foot Pedal" (14), or "Cable operated Foot Pedal" For optimum operation of the camera check that only units being used are checked (i.e. with a tick) Testing After commissioning or set up of the VistaCam CL.iX carry out all testing according to standards IEC , e.g. for patient conductivity, etc, and document /10

15 Use of the Appliance 11. Operation 11.1 Important information concerning the handpiece Damage to handpiece: The handpiece can easily be damaged if it is allowed to fall on the floor. Do not put the handpiece down on a working surface or table top; always replace in the battery charger or handpiece holder (optional). The optical lens can be damaged if it comes into contact with sharp metal objects or similar. Do not place the handpiece between surgical instruments. The quality of the image can be greatly affected by dirt on the optic. Observe the cleaning instructions under section Using hygienic protective covers Hygienic protection For reasons of simple hygiene the VistaCam CL.iX must only be used together with a hygienic protective cover when used for intraoral areas. Hygienic protective covers are disposable items and must not be reused. Hold the handpiece such that the window of the optic itself faces downwards. Hold the disposable protective sheath so that the blue stripe is facing upwards. Lift the white edge of the disposable protective sheath and carefully insert the optic. Once the tip of the optic is completely at the top, the sheath should be stretched a further 2-3 mm so that the cover is tight. Use the tip of a finger to carefully press the sheath tight against the window of the optic itself, in order to remove any small air pockets that may be present between the sheath and the window of the optic. Hold the blue stripe of the disposable protective sheath tightly and pull the upper plastic side of the packaging towards the optic. Unpeel the paper underside off and dispose of. Slide the hygienic protective cover off carefully after use and dispose. 2009/10 15

16 11.3 Switching VistaCam CL.iX on or off 1 Remove the handpiece (1) from its battery charger (6), or from its holder (optional extra) (2). The camera will automatically switch on. Or Pressing the switch (1c) once briefly is sufficient to switch the VistaCam CL.iX on. Press the switch for ca. 5 seconds and the VistaCam CL.iX switches off The camera automatically switches off after 10 minutes continuous operation. The image editing software DBSWIN can be used to switch it back on using the Live/Freeze function keys. 1c /10

17 11.4 Instructions for using IFC Optic Turn the adjusting ring (15) on the handpiece in order to focus the IFC Optic. 15 Because of the very good depth of field of the VistaCam CL.iX, refocussing in the mouth of the patient is not necessary. Macro Intraoral Extraoral Using distance spacer (optional) The special image distance spacer has the advantage of allowing repeat images to be captured. Before use check carefully that the spacer (16) has been correctly disinfected, cleaned and sterilised, see Fix the spacer (over the disposable protective cover) in place: long distance spacer for adults, short distance spacer for children or for some position requirements (inaccessible spot) Keep the distance spacers out of the reach of children! Danger of swallowing! 2009/10 17

18 1a 11.6 Taking images Start DBSWIN and select patient. Select Video-module. The live image is now displayed on the monitor. Images can be recorded a number of ways: 1.Standard setting: operating the manual release (1a). 2.Optional setting: operating the foot pedal (with cable or radio-operated foot pedal) Operating the manual release causes a short, light vibration and an acoustic signal can be heard at the base station. 24 Operating the cable or radio-operated foot pedal causes an acoustic signal at the base station. Images can now be recorded and the monitor can switch between Live Mode and Freeze Mode. Freeze frame images: Press the fingers together on the pressure sensitive operating ring of the manual release. The freeze frame is now displayed on the monitor. Live images: Press the fingers together on the pressure sensitive operating ring of the manual release. The live image is now again displayed on the monitor. 3a 3b Function keys on cable (3a) and radio-operated foot pedals (3b) (optional extras) (17) Select and activate image (18) Switch between freeze frame and live image (19) Save image /10

19 26 1d 6 6a 11.7 Care of handpiece Place the handpiece back in the battery charger or in its holder (optional extra). The handpiece should never be placed on the working table or tray of the treatment unit (danger of it falling) or between surgical instruments (the optical lens can easily be damaged if it makes contact with sharp metalic objects). When the LEDs (1d) blink 6 times, then the battery level is low and sufficient only for approx. 5 minutes operation of the handpiece. Carry out the following procedure in this case: Place the handpiece into the battery recharging unit for at least 5 minutes. green LED (6a) blinks green LED (6a) lit fast charging mode running. battery charged unit ready battery is fully charged after ca. 1.5 h. 2009/10 19

20 Disinfection and Cleaning Only disinfectants and cleaning agents specifically approved by Dürr Dental should be used. Other cleaning and disinfectant agents could damage the VistaCam CL.iX and its accessories. IstaCam 12.1 Cleaning the optical lens We strongly recommend using the cleaning set for Dürr VistaCam-Optic, order number: The use of disinfectant wipes, or a fluid disinfection agent to clean the optic part is NOT recommended. These could have dirt deposits Cleaning and disinfecting handpiece and other accessories The handpiece and accessories can be cleaned and disinfected using a disinfection cloth such as Dürr FD 350. Damage to the handpiece: Do not use any sharp or abrasive cleaning materials. The surface of the appliance may be damaged. Do NOT place the handpiece in an autoclave, immerse in disinfectant or clean using a disinfectant spray. These could all lead to the handpiece being destroyed Cleaning, disinfection and sterilisation of distance spacers Set up according to ISO When cleaning, disinfecting, sterilising and storing the special adapters for spacing (16), observe the relevant national and local regulations! Preparation for cleaning If necessary, remove coarse dirt particles using a disinfected disposable cloth (e.g. FD 350) /10

21 Automatic cleaning and disinfection, Operate the cleaning and disinfection appliance according to the manufacturer's instructions. 1. Place the spacer adapter in the sterilisation unit such that inner surfaces can be wellrinsed and water can drain off. 2. Set the cleaning and disinfection cycles according to the manufacturer's instructions. 3. After the cleaning and disinfection cycles check the spacer for any remaining signs of dirt, if necessary repeat the cleaning cycle. Manual cleaning and disinfection, Cleaning in a wet-chemical method using a disinfectant which is VAH/DGHM listed : Submerge the spacer adapter completely in an Instrument disinfection instrument disinfection cleaning agent, e.g. Dürr ID 212, ID 212 forte or ID 213; observe the manufacturer's instructions. After the cleaning and disinfection cycles check the spacer for any remaining signs of dirt, if necessary repeat the cleaning cycle. Rinse the spacer well. Dry using a hygienic disposable cloth or under the application of compressed air. Visual inspection Frequent use and subsequent cleaning of this part will not have any effect on the spacer. The life expectancy will depend largely on daily wear and whether there is any damage during usage. Check the spacer and, if necessary, dispose of any damaged spacer. Before disposing of a used spacer adapter disinfect and sterilise well. Packaging Sterilise the distance spacer either packed or unpacked in a container or in sterile product packaging. Use suitable sterile product packaging! Sterilisation Before using the distance spacer place it in a vacuum-steriliser unit at 134 C for at least 3 minutes at 3 bar absolute / 0.3 MPa absolute and humidity of 100 %! Do not exceed 134 C! Do not put these spacers into hot air sterilisation units! Place filter paper on the floor of the sterilisation tray. Avoid any metal contact of the distance spacer with other instruments or the edges of the tray. Do not place spacers touching the heating elements or so they can come into contact with the inner edges of the middle tray. Always sterilise the spacers together with other instruments, as this ensures a constant and balanced distribution of heat. Storage Store the spacers with adequate contamination protection. The above instructions for the correct preparation of the distance spacer adapters for reuse has been validated by Dürr Dental as suitable. The user is responsible for ensuring that these steps are carried out using the appropriate equipment, materials and by suitably trained staff in order to achieve the desiraed results. To ensure this, it is necessary to monitor and validate the process. Any deviation from the instructions described above by the operator could lead to negative consequences regarding their effectiveness. 2009/10 21

22 13. Maintenance Only use Original Equipment Manufacturing spare parts for repairs, otherwise guarantees and warranties may be infringed. Provide for a safe and ecologically correct disposal of all replaced parts b 13.1 Changing the battery pack Press the clip contact (20) and extract the rechargeable battery pack (1b). Put fresh rechargeable battery pack in place. Place the handpiece into the battery recharging unit (6). 1 green LED (6a) blinks green LED (6a) lit fast charging mode running. battery charged unit ready battery is fully charged after ca. 1.5 h. Dispose of used rechargeable battery packs correctly. See section 1.3 Appliance disposal 30 1b 13.2 Battery care In order to gain the maximum possible life from the battery it is advisable to completely discharge the battery every 3 months and then completely recharge. In order to minimise damage to the VistaCam CL.iX rechargeable battery pack the rechargeable battery pack should be removed: any break of 4 weeks or longer in use (e.g. holiday) transport (e.g. repair) a /10

23 Trouble-shooting 14. Tips for Operators and Service Technician 14.1 Problem 14.2 Possible cause 14.3 Solution 1. Image is opaque, milky The hygienic protective cover has not been correctly placed See section 11.2 Using the hygienic protective cover IFC Optic is dirty Some sort of fluid has seeped into the optic on the handpiece. See section 12.1 Cleaning the optical lens The handpiece must be sent for repair to Dürr Dental. 2. Image is too dark LEDs are defect. The handpiece must be sent for repair to Dürr Dental. 3. No image Mains cable or USB cable not connected. Cable has not, or not correctly, been connected Monitor not switched on or defect Handpiece not switched on Discharge the battery pack Battery pack does not recharge. The life time of the rechargeable battery pack has been exceeded. See section 9. Electrical connections 10. Inbetriebnahme 11. Bedienung Connect cables correctly Switch on monitor. Press switch (1c). Place battery pack in battery charger Measure the voltage of the battery across the poles V = battery o.k V = battery defect use new rechargeable battery pack (ca. 500 charge cycles) 4. Foot pedal does not function Battery flat Wrong channel selection under DBSWIN "Video Properties/ Base station". Correct source in DBSWIN "Video- Properties/Base station" activated Change battery Set correct channel. Activate source (tick box) 5. Base station does not recognise camera - blue LED of base station not lit. Channel selection under DBSWIN is not identical to that selected on handpiece Set correct channel, see section /10 23

24 Dürr Dental AG Höpfigheimer Strasse Bietigheim-Bissingen Germany Fon:

INSTALLATION AND OPERATING INSTRUCTIONS DÜRR VISTACAM, VISTACAM CL

INSTALLATION AND OPERATING INSTRUCTIONS DÜRR VISTACAM, VISTACAM CL INSTALLATION AND OPERATING INSTRUCTIONS DÜRR VISTACAM, VISTACAM CL VistaCam VISTA CAM VistaCam CL VISTA CAM 2 CONTENT Important information 1. Notes... 4 1.1 Test of conformity... 4 1.2 General Notes...

More information

Manual MADE IN GERMANY

Manual MADE IN GERMANY Manual MADE IN GERMANY Contents Important Information 1. General.............................. 4 1.1 Note on Conformity................ 4 1.2 General Notes..................... 4 1.3 Disposal of appliance.............

More information

Thank you for your purchase USER MANUAL

Thank you for your purchase USER MANUAL Thank you for your purchase USER MANUAL MANUAL ICONS Warning: situations involving injury risk of the user or other persons. Attention: situations, when damage of device or other equipment may be caused.

More information

I-CAM PLUS USER MANUAL

I-CAM PLUS USER MANUAL I-CAM PLUS USER MANUAL 1. I-CAM PLUS Intraoral Camera 1.1 Features The I-CAM PLUS Intraoral Camera provides live video display, freeze, and capture capabilities for dental imaging. Displays live video

More information

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116 INSPECTION CAMERA MODEL NO: CIC2410 PART NO: 6470385 OPERATION & SAFETY INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Inspection Camera. Before attempting to use this product, please

More information

Medimaging Integrated Solution Inc.

Medimaging Integrated Solution Inc. Medimaging Integrated Solution Inc. (MiiS) 1F, No. 7, R&D Rd II, Hsinchu Science Park, Hsinchu, TAIWAN 30076, R.O.C Issued date: Jan. 30, 2012 1 of 20 TABLE OF CONTENTS 1. Category 2. Symbols 3. Warnings

More information

HX1 Bluetooth Stereo Headset

HX1 Bluetooth Stereo Headset HX1 Bluetooth Stereo Headset Ref. nr.: 130.115 INSTRUCTION MANUAL V1.1 ENGLISH Congratulations to the purchase of this Max product. Please read this manual thoroughly prior to using the product in order

More information

User Manual. Please read the Important Instructions for Use overleaf.

User Manual. Please read the Important Instructions for Use overleaf. QUICKLOOK User Manual Please read the Important Instructions for Use overleaf Important Instructions for Use Use only the charger provided. Use of another charger could result in irreparable damage to

More information

QUICKLOOK. User Manual. Please read the Important Instructions for Use overleaf

QUICKLOOK. User Manual. Please read the Important Instructions for Use overleaf QUICKLOOK User Manual Please read the Important Instructions for Use overleaf Important Instructions for Use Use only the charger provided. Use of another charger could result in irreparable damage to

More information

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018 Operating manual Diagnostic adapter VAS 611 009 CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 1 of 11 Imprint Title: Operating manual of diagnostic adapter VAS 611 009 Manufacturer: CAR-connect

More information

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids INSTRUCTIONS FOR USE RECHARGEABLE System for Hearing Aids Limited Warranty ZPower s exclusive limited warranty is available at www.zpowerhearing.com. You may also obtain a copy of ZPower s Limited Warranty

More information

Weatherproof IR Color Day/Night Cameras

Weatherproof IR Color Day/Night Cameras Weatherproof IR Color Day/Night Cameras Products: CFC6042IR, CFC6042IR2, CFC6042IR3, CFC6043IR, CFC6043IR2, CFC6043IR3 Please read this manual before installing and using this camera and always follow

More information

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Konica Minolta s industrial instruments. Safety Precautions

Konica Minolta s industrial instruments. Safety Precautions Konica Minolta s industrial instruments Safety Precautions Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as result of incorrect use of the instrument.

More information

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23 Product Manual ASL Document Ref.: U-0618-0103.doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23 RCS01 RPA Transmitter Charging Station This equipment is designed and manufactured

More information

User Manual MagniLink One

User Manual MagniLink One User Manual MagniLink One LVI Low Vision International Verkstadsgatan 5 Tel: +46 470-727700 info@lvi.se SE-352 46 Växjö Faks: +46 470-727725 www.lvi.se Table of Contents 1 About LVI... 5 2 Introduktion

More information

QUICKLOOK. User Manual. Please read the Important Instructions for Use overleaf

QUICKLOOK. User Manual. Please read the Important Instructions for Use overleaf QUICKLOOK User Manual Please read the Important Instructions for Use overleaf Important Instructions for Use Use only the charger provided. Use of another charger could result in irreparable damage to

More information

Operating Instructions

Operating Instructions Operating Instructions INTERCHANGEABLE LENS FOR DIGITAL CAMERA Model No. H-F007014 Before use, please read these instructions completely. E -1 Contents Information for Your Safety... 2 Precautions... 4

More information

IR Varifocal IP66 Weatherproof Cameras

IR Varifocal IP66 Weatherproof Cameras IR Varifocal IP66 Weatherproof Cameras Products: CFC6067VF, CFC6067VF2 Please read this manual before using your camera, and always follow the instructions for safety and proper use. Save this manual for

More information

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual LED Colour Flood 10W / 30W RGB LED floodlight user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Dr. Benny Electric Nasal Aspirator Medical device INSTRUCTION MANUAL

Dr. Benny Electric Nasal Aspirator Medical device INSTRUCTION MANUAL Dr. Benny Electric Nasal Aspirator Medical device Produced by 8220 Balatonalmádi, Kompolthy utca 9. www.friendlytrade.eu Page 1 of 8 Date: 01. 02. 2013. Read carefully before using the device! Contents

More information

Druck DPI 620 advanced modular calibrator

Druck DPI 620 advanced modular calibrator GE Sensing & Inspection Technologies A1.1 DPI 620: Channel 1 (CH1) Druck DPI 620 advanced modular calibrator safety and quick reference guide - K0454 Measure (M) / Source (S) / Power (P) a ±30 V (M) b

More information

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300. Retain these instructions for future reference

BORESCOPE INSTRUCTIONS INSPECTION CAMERA RANGE RBS100 RBS200 RBS300.  Retain these instructions for future reference BORESCOPE INSPECTION CAMERA RANGE RBS100 RBS200 RBS300 INSTRUCTIONS Retain these instructions for future reference www.ringautomotive.co.uk 1 Instructions for Ring Automotive Borescope Inspection Camera

More information

MX3 BT LED Party Tube

MX3 BT LED Party Tube MX3 BT LED Party Tube Ref. nr.: 130.121 INSTRUCTION MANUAL V1.1 ENGLISH Congratulations to the purchase of this Max product. Please read this manual thoroughly prior to using the product in order to benefit

More information

Network Camera. Quick Guide DC-B1203X. Powered by

Network Camera. Quick Guide DC-B1203X. Powered by Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

FlashMax P4 Ortho Manual

FlashMax P4 Ortho Manual FlashMax P4 Ortho Manual FlashMax P4 Ortho orthodontic light pen Page 3 Content WARNINGS 4 Technical description Technical specifications Environmental conditions for intended use 5 Preparing to use the

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

USER GUIDE. Waterproof Borescope. Models BR300 and BR350

USER GUIDE. Waterproof Borescope. Models BR300 and BR350 USER GUIDE Waterproof Borescope Models BR300 and BR350 Introduction Thank you for selecting the Extech Instruments Model BR300/BR350 Waterproof Borescope. The Waterproof Borescope can be fully immersed

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

TVAC25100 TVAC25110 User manual

TVAC25100 TVAC25110 User manual TVAC25100 TVAC25110 User manual Version 11/2010 Original user manual. Keep for future use. 12 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the

More information

USERS MANUAL DIGI-DOC.COM

USERS MANUAL DIGI-DOC.COM USERS MANUAL DIGI-DOC.COM 800-518-1102 SAFETY INSTRUCTIONS THIS SYMBOL ALERTS THE USER THAT IMPORTANT LITERATURE CONCERNING THE OPERATIONS AND MAINTENANCE OF THIS UNIT HAVE BEEN INCLUDED OR IS AVAILABLE

More information

Axiomet AXB Safety instructions

Axiomet AXB Safety instructions Axiomet AXB350 1. Safety instructions Failure to follow the instructions listed below may result in electric shock or personal injury. Please read this manual carefully and thoroughly before using this

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Variable-Speed Vortex Mixer

Variable-Speed Vortex Mixer Variable-Speed Vortex Mixer User Guide Version 1.1 IEC connector Retort rod fitting Rubber cup Speed control dial Power on/off button Mode button Figure 1: Vortex Mixer Figure 2: Front panel 2 Variable-Speed

More information

Gobo Projector XP 80W

Gobo Projector XP 80W Gobo Projector XP 80W User Manual Order code: EQLED084 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

PV Module Installation Instructions

PV Module Installation Instructions Name 1601A Page 1 / 8 Name 1601A Page 2 / 8 1 Introduction Thanks for purchasing PV modules of HT SOLAR ENERGY JOINT STOCK COMPANY This manual refers to PV modules manufactured and sold by HT Turkey. This

More information

E8431 First Edition Model: T00CP

E8431 First Edition Model: T00CP Quick Start Guide E8431 First Edition Model: T00CP Copyright 2013 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced,

More information

1 Channel Strobe Controller ORDERCODE 40226

1 Channel Strobe Controller ORDERCODE 40226 1 Channel Strobe Controller ORDERCODE 40226 Congratulations! You have bought a great, innovative product from Showtec. The Showtec Strobe Controller brings excitement to any venue. Whether you want simple

More information

BEETLE /Fusion Compact. Installation Guide

BEETLE /Fusion Compact. Installation Guide BEETLE /Fusion Compact Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

Table of contents 2 / 8

Table of contents 2 / 8 Manual Speaker SM5A Table of contents 1. Safety instructions... 3 1.1. Instructions for a safe and efficient operation... 3 1.2. Further safety instructions... 4 1.3. Designated use... 4 2. Introduction...

More information

Digital Night Vision Device Digital+ Series NV-440D3/NV-650D3/NV-760D3

Digital Night Vision Device Digital+ Series NV-440D3/NV-650D3/NV-760D3 Digital Night Vision Device Digital+ Series NV-440D3/NV-650D3/NV-760D3 Instruction Manual Digital Night Vision Device Digital Series NV-440D3 / NV-650D3 / NV-760D3 Before using the device for the first

More information

OMM200 and OMM200T. Metallurgical Microscope

OMM200 and OMM200T. Metallurgical Microscope OMM200 and OMM200T Metallurgical Microscope Instruction Manual (Please read the manual carefully before using the microscope) Contents Safety ----------------------------------------------------------------------------

More information

LED-Illumination with Control Unit Ident.-No

LED-Illumination with Control Unit Ident.-No A HAAG-STREIT COMPANY MÖLLER-WEDEL OPTICAL GmbH, Rosengarten 10, D-22880 Wedel with Control Unit Ident.-No. 773 190 01 Valid from Hardware / Software Rev. / SN 1.0 IDENT.-NO. 217 321 09 Document Version

More information

We congratulate you on the purchase of a Univet illumination system - Made in Italy. To ensure safe use please observe the following notes.

We congratulate you on the purchase of a Univet illumination system - Made in Italy. To ensure safe use please observe the following notes. MANUFACTURER: Univet s.r.l. via Giovanni Prati, 87 25086 Rezzato (BS) Italy www.univet-optic.com We congratulate you on the purchase of a Univet illumination system - Made in Italy. To ensure safe use

More information

BAM Labs Biometric Monitoring System. Instruction Manual

BAM Labs Biometric Monitoring System. Instruction Manual BAM Labs Biometric Monitoring System Instruction Manual 2 Contents Customer Instructions...4 Intended Use...4 IMPORTANT SAFETY INSTRUCTIONS...5 WARNINGS...6 FCC Warning...7 LED Feedback...9 Connecting

More information

COMPACT LED DESK LAMP WITH LCD DISPLAY

COMPACT LED DESK LAMP WITH LCD DISPLAY COMPACT LED DESK LAMP WITH LCD DISPLAY User manual, Operating- and safety instructions, Warranty conditions LED 12 MON Item no.: MROS501 Getting started and operation 1 180 1. Setting up Place the LED

More information

5 B&W Rear View System Camera

5 B&W Rear View System Camera 5 B&W Rear View System Camera Instruction Manual MODEL: CA453 www.lorexcctv.com Copyright 2007 LOREX Technology Inc. Thank you for purchasing the Lorex 5 Black & White Rear View System Camera. This system

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

* When purchased as baby monitor set A , only one manual and warranty card is included. English 16

* When purchased as baby monitor set A , only one manual and warranty card is included. English 16 Congratulations on the purchase of your video monitoring system»mona«. You have chosen highly modern and reliable devices, which will provide valuable service for your home. Please read this manual thoroughly

More information

RGB Power Batten. User Manual. Order code: EQLED032

RGB Power Batten. User Manual. Order code: EQLED032 RGB Power Batten User Manual Order code: EQLED032 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Electro Magnetic Compatibility (EMC)

Electro Magnetic Compatibility (EMC) Electro Magnetic Compatibility (EMC) This equipment complies with the European rules for EMC according to EN5501, EN5500 and EN5008-1. The equipment conforms to the EMC directive and low-voltage directive.

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2017 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

374 FC/375 FC/376 FC. Clamp Meter. Safety Information 374 FC/375 FC/376 FC Clamp Meter Safety Information 3-Year Limited Warranty. Go to www.fluke.com to register your Product, read the Users Manual, and find more information. A Warning identifies conditions

More information

Foot switch. Installation, operation and maintenance manual

Foot switch. Installation, operation and maintenance manual Installation, operation and maintenance manual ST Foot switch Read this manual before installing, operating or maintaining this actuator. Failure to follow safety precautions and instructions could cause

More information

User Guide for the Wireless Clip-on Headset (HS-21W) Issue 1

User Guide for the Wireless Clip-on Headset (HS-21W) Issue 1 User Guide for the Wireless Clip-on Headset (HS-21W) 9236329 Issue 1 DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product HS-21W is in conformity with

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE INSPECTION TOOL Inspection Video Camera with Color LCD Monitor Model: 8802LE,8803LE EU Environmental Protection Waste electrical products should not be disposed of with household waste. Please recycle

More information

IPCB42501 / IPCB42551

IPCB42501 / IPCB42551 IPCB42501 / IPCB42551 Installation manual Version 03/2017 IPCB42501 IPCB42551 English translation of the original German user manual. Retain for future reference. uk Introduction Dear Customer, Thank you

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

Infrared Dome CCD Camera User Manual

Infrared Dome CCD Camera User Manual Infrared Dome CCD Camera User Manual Products: CDC3115IR, CDC3114VF, CDC3114VF2, CDC3114IR2 Please read this manual before installing and using this camera and always follow instructions for proper use.

More information

2 Mesa Ethernet Dock User s Manual

2 Mesa Ethernet Dock User s Manual owner s manual Mesa Ethernet Dock The Mesa Ethernet Dock is an optional accessory that provides an ethernet port for networking, power input jack, USB client port, and a mounting station for the Mesa Rugged

More information

<User Manual> PM-150

<User Manual> PM-150 PM-150 ENGLISH TABLE OF CONTENTS: PREFACE ------------------------------------------------------------ 1 DISCLAIMER ------------------------------------------------------- 1 PRECAUTIONS -----------------------------------------------------

More information

-bio. Densitometer DEN-1B Operating instructions

-bio. Densitometer DEN-1B Operating instructions -bio Densitometer Contents 1 Safety...4 2 General Information...6 3 Getting started...8 4 Operation of...10 5 Maintenance...12 6 Specifications...13 7 Guarantee and service...14 Version 1.01 - May 2012

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

User Guide Microsoft Portable Power (DC-21)

User Guide Microsoft Portable Power (DC-21) User Guide Microsoft Portable Power (DC-21) Issue 1.0 EN-US User Guide Microsoft Portable Power (DC-21) Contents For your safety 3 About your portable charger 4 Keys and parts 5 Charge your portable charger

More information

Technical Manual Room temperature controller

Technical Manual Room temperature controller 1473-1-8563 03.07.2014 Technical Manual Room temperature controller RTC-F-1 ABB-free@home Content 1 Notes on the instruction manual 3 2 Safety 4 2.1 Used symbols 4 2.2 Intended use 5 2.3 Improper use 5

More information

LED SPIDER MOVING HEAD LIGHT

LED SPIDER MOVING HEAD LIGHT LED SPIDER MOVING HEAD LIGHT MJ-1031C (4IN1) INSTRUCTION MANUAL Thank you for choosing our LED spider moving head light. For the sake of your safety, Please read and follow these instructions carefully

More information

xbrick Full-Colour 16 3W LED floodlight user manual

xbrick Full-Colour 16 3W LED floodlight user manual xbrick Full-Colour 16 3W LED floodlight user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (9546) 9223-0 email: info@thomann.de Internet: www.thomann.de 15.11.2011

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

7 Digital Photo Frame

7 Digital Photo Frame 7 Digital Photo Frame Instruction manual L7DPF17 12 month manufacturer's warranty -------------------------------------------------------------------------- --------------------------------------------------------------------------

More information

Ready...Set...Go. Pick a spot and plug it in. Download the Maginon App for Android or ios and install your WiFi Video Camera in a minute.

Ready...Set...Go. Pick a spot and plug it in. Download the Maginon App for Android or ios and install your WiFi Video Camera in a minute. Ready...Set...Go. Pick a spot and plug it in. Download the Maginon App for Android or ios and install your WiFi Video Camera in a minute. Need Help? Download the user manual here: http://www.maginon.com/downloads/usa/user-manual-ipc-30fhd.pdf

More information

DDE-B Robot station Ref. DDRE-B

DDE-B Robot station Ref. DDRE-B DDE-B Robot station Ref. DDRE-B Packing List Features The following items should be included: USB-A connector 2.8 Color TFT screen 2 Tools Control Unit... 1 unit Ref. DDE-1B (120V) DDE-2B (230V) DDE-9B

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

Optional add-on cassette Attachment Instruction manual

Optional add-on cassette Attachment Instruction manual E6580774 Optional add-on cassette Attachment Instruction manual 1. INTRODUCTION 3 2. CONNECTION TO THE INVERTER 4 2.1 Fixing the option alone 4 2.2 Connection to the inverter 6 3. SPECIFICATION 8 4. WARRANTY

More information

User manual Model: VIU-800 Brand:

User manual Model: VIU-800 Brand: User manual Model: VIU-800 Brand: - 1 - This manual s main purpose is to introduce the correct way of using the Voter Identification Unit / Electronic Voting Machine (hereinafter referred to as "the device").

More information

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket

Version 1.0 December isappos 4 / isappos 5 Scanner Jacket User Manual Version 1.0 December 2016 isappos 4 / isappos 5 Scanner Jacket Copyright Copyright 2016 All Rights Reserved Manual Version 1.0 The information contained in this document is subject to change

More information

DC-D2212R / DC-D2212WR

DC-D2212R / DC-D2212WR Network Camera Quick Guide / DC-D2212WR Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

WIRELESS POWERLINK USER MANUAL

WIRELESS POWERLINK USER MANUAL WIRELESS POWERLINK USER MANUAL Contents General... 3 Wireless Powerlink... 3 Package Contents... 4 Disposal of Old electrical Devices... 6 Installation... 7 Pairing Function... 7 Connecting the Devices...

More information

Starlit Dance Floor. User Manual

Starlit Dance Floor. User Manual Starlit Dance Floor User Manual Order codes: 500W Power Supply - LEDJ405 750W Power Supply - LEDJ427 1000W Power Supply - LEDJ428 1500W Power Supply - LEDJ429 White Remote Control Pack - LEDJ406 White

More information

CX1 Outdoor Color-Changing Wireless Bluetooth Speaker Please fully charge the speaker prior to first use!

CX1 Outdoor Color-Changing Wireless Bluetooth Speaker Please fully charge the speaker prior to first use! CX1 Outdoor Color-Changing Wireless Bluetooth Speaker 130.109 Please fully charge the speaker prior to first use! 1 ENGLISH Congratulations to the purchase of this Max product. Please read this manual

More information

Octostrip ORDERCODE 42220

Octostrip ORDERCODE 42220 Octostrip ORDERCODE 42220 Congratulations! You have bought a great, innovative product from Showtec. The Showtec LED Octostrip brings excitement to any venue. Whether you want simple plug-&-play action

More information

GPS167 Portable CD Radio User Guide

GPS167 Portable CD Radio User Guide GPS167 Portable CD Radio User Guide IMPORTANT: Please read all instructions carefully before use and keep for future reference Introduction Thank you for choosing this Goodmans Portable CD Radio. You can

More information

ARGO LAB SKO-D XL Orbital and Linear digital shaker. User manual

ARGO LAB SKO-D XL Orbital and Linear digital shaker. User manual ARGO LAB SKO-D XL Orbital and Linear digital shaker User manual 1 Contents 1. Warranty... 2 2. Safety instruction... 3 3. Proper use... 3 4. Receiving Inspection... 3 4.1 Listing of Items... 3 5. Trial

More information

EC Series. Safety Guide

EC Series. Safety Guide EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support

More information

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.

More information

Large Police Light 100W ORDERCODE 80361

Large Police Light 100W ORDERCODE 80361 Large Police Light 100W ORDERCODE 80361 Congratulations! You have bought a great, innovative product from Showtec. The Showtec Large Police Light brings excitement to any venue. You can rely on Showtec,

More information

PAR-WT50R-E PAR-WR51R-E

PAR-WT50R-E PAR-WR51R-E Wireless Remote Controller and Receiver PAR-WT50R-E PAR-WR51R-E This manual explains installation of the PAR-WR51R-E wireless receiver and the PAR-WT50R-E wireless remote controller, and settings of these

More information

DC-D4213RX DC-D4213WRX

DC-D4213RX DC-D4213WRX Network Camera Quick Guide DC-D4213RX DC-D4213WRX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Thanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference.

Thanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference. CONTENTS Thanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference. 01Read This First...01 Product Information...01 Standard Package Contents...02

More information

LIGHT BRICK - 12 X 3W TRI-COLOUR

LIGHT BRICK - 12 X 3W TRI-COLOUR www.prolight.co.uk LIGHT BRICK - 12 X 3W TRI-COLOUR (Order code: LEDJ162) USER MANUAL Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep

More information

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Blitzer RGB Strobe. User Manual. Order code: EQLED365 Blitzer RGB Strobe User Manual Order code: EQLED365 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Magnetic Immunoassay Reader Operator Manual

Magnetic Immunoassay Reader Operator Manual Page 1 of 8 Magnetic Immunoassay Reader Operator Manual Table of contents 1 Introduction...1 2 Magnetic Immunoassay Reader...1 2.1 Contact information and spare parts...1 3 Contents of delivery...1 4 Technical

More information