Best Practice of HUAWEI OceanStor T Series Solutions for Key VMware Applications

Size: px
Start display at page:

Download "Best Practice of HUAWEI OceanStor T Series Solutions for Key VMware Applications"

Transcription

1 Best Practice of HUAWEI OceanStor T Series Solutions for Key VMware Applications

2 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Website: Huawei Industrial Base Bantian, Longgang Shenzhen People's Republic of China support@huawei.com i

3 About This Document About This Document Purpose This document describes the best practice for using HUAWEI OceanStor T series on the VMware vshpere 5.0 platform, including network design, configuration method and performance tuning for storage systems and VMware virtual machines (VMs). The best practice in this document can meet the requirements of configuration optimization in a variety of application scenarios. Intended Audience This document is intended for: Marketing engineers Technical support engineers Maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results. NOTICE is used to address practices not related to personal injury. ii

4 About This Document Symbol Description Calls attention to important information, best practices and tips. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. iii

5 Contents Contents About This Document... ii 1 Overview Component Introduction Introduction to HUAWEI OceanStor T Series Storage Systems Introduction to VMware vsphere Storage Network Design Reliability Design Bandwidth Design Load Balancing Design Network Design Optimizing Storage System Configuration Configuration Process Selecting Disks Configuring RAID Groups RAID Group Levels RAID Group Capacity Hot Spare Disk and Reliability RAID Group Performance Evaluation LUN Configuration Owning Controller Stripe Depth Prefetch Policies Write-Back Policies Host Mappings VM Configuration Optimization VMFS and RDM Suggestion on VMFS Volume Configuration Suggestion on Capacity Configuration VMFS Volume Expansion Exclusive Volume or Shared Volume Suggestion on Virtual Disk Configuration iv

6 Contents Choosing a Virtual Disk Format Virtual Disk Modes SCSI Bus Sharing Methods Configuring Partition Alignment Suggestion on RDM Configuration Configuring I/O Queue Depth DRS and HA Are Recommended Summary A Glossary v

7 1 Overview 1 Overview With the advent of virtualization, companies are falling over themselves to deploy VMware VM-based applications. HUAWEI OceanStor T series storage systems have been optimized for VMware VMs and offer comprehensive solutions in the infrastructure, service key applications, and backup and disaster recovery of virtual data centers. This document introduces how to select the proper storage system on the VMware vsphere 5.0 platform, including storage system selection, storage system network design, storage system configuration optimization, and the configuration optimization of the VMware vsphere platform. You can achieve the best performance and reliability by configuring the storage system as recommended in this document. If you are deploying storage systems on the VMware platform, you are advised to configure the storage systems as recommended in this document. 1

8 2 Component Introduction 2 Component Introduction About This Chapter 2.1 Introduction to HUAWEI OceanStor T Series Storage Systems 2.2 Introduction to VMware vsphere 2.1 Introduction to HUAWEI OceanStor T Series Storage Systems Targeted at high-level storage applications, HUAWEI OceanStor T series is developed on industry-leading hardware, high-density disk design, TurboModule high-density I/O modules, and the hot swap design. Besides, HUAWEI OceanStor T series integrated a variety of advanced technologies, including the TurboBoost three-level performance acceleration technology and multi-data redundancy technology. These technologies not only meet the requirements of big database OLTP/OLAP, high-performance computing, digital media, Internet operation, integrated storage, backup, disaster recovery, and data transfer, but also ensure service security and continuity. Figure 2-1 HUAWEI OceanStor T series storage systems 2

9 2 Component Introduction More importantly, Huawei S5500T/S5600T/S5800T/S6800T comes with such features as high performance, high reliability, high scalability, and low power consumption. Table 2-1 Features provided by HUAWEI OceanStor T series storage systems High Performance SmartCache Cache intelligent prefetch Dual-controller dynamic load balancing VAAI VM performance acceleration The SmartCache resource pool consists of one or multiple SSDs. By collecting the real-time information about the access frequency of the data blocks in the storage system, SmartCache dynamically transfers the hotspot data blocks with high access frequency from the HDD to the SmartCache resource pool. Because an SSD has a faster access speed, SmartCache improves the read-performance and the access efficiency of the host. Cache intelligent prefetch can identify the current I/O sequence and enable/disable the Cache prefetch function based on different service models. Based on different application scenarios, you can set the optimized prefetch length by using Cache intelligent prefetch. In addition to significantly improving the host read performance, Cache intelligent prefetch reduces disk access frequency, prolonging disk lifespan. Working in an Active-Active mode, the two controllers can concurrently process the I/O requests from the host and share the data storage loads. This avoids the situation that one controller is over loaded but the other one is left unused. The dual-controller dynamic load balancing not only reduces the load on a single controller, but also utilizes system resources more properly, improving both system efficiency and performance. The VMware VAAI technology is supported. VAAI can significantly improve the usage effectiveness of the storage space in S5600T on the VMware platform and balances loads between the server on the VMware platform and the storage system, reducing load on the host and improving storage efficiency. 3

10 2 Component Introduction High Reliability Built-in BBUs+data coffers Disk pre-copy Critical data protection The built-in BBUs+data coffers design is used. Small, low-cost, redundant, and hot swappable, built-in BBUs can supply power to controllers and the coffer after the external power fails. Data in caches can be written into disks after the external power failure, and data integrity and reliability are protected. After obtaining the firsthand disk status information by using the disk predicting technology, disk pre-copy uses the pre-copy algorithms to analyze disk running status to calculate the probability of disk failure. If some disks are predicted to fail, disk pre-copy copies the data in those disks to a hot spare disk. This predicting act not only shortens the time needed for reconstruction or eliminates the necessity for reconstruction after disk failure but also reduces the possibility of disk failing again during reconstruction, improving storage security. HyperImage (virtual snapshot), HyperCopy (LUN copy), HyperMirror/S (synchronous copy), and HyperMirror/A (asynchronous copy) are used to meet the requirements of backup, disaster recovery, and data transfer. 2.2 Introduction to VMware vsphere By using the virtualization products offered by VMware, you can run multiple operating systems in one physical machine. For each operating system, you can set virtual partitions and configuration and switch one operating system to another. VMware vsphere is a suite released by VMware for data centers. VMware vsphere transfers data centers to a simplified cloud computing infrastructure by using virtualization, enabling IT departments to provide flexible and reliable IT services. In addition to vitalizing and integrating basic physical hardware resources, VMware vsphere provides abundant virtual resources for data centers. VMware vsphere consists of the following component layers: Table 2-2 VMware vsphere components Name Infrastructure service Description Infrastructure service The basic architecture service is a service set used for collecting, integrating, and allocating hardware basic architecture resources. It includes vcomputer, vstorage, and vnetwork, which are responsible for vitalizing computing resources, storage resources, and network resources respectively and integrating the resources in a virtual environment for unified management. 4

11 2 Component Introduction Name VMware vcenter Server Client Description VMware vcenter Server provides a unified management platform for data centers and basic data center services, such as access control, performance monitoring, and configuration. You can access the VMware vsphere data center management platform using vsphere Client or Web Access (on a Web browser). In addition to solving the problems of over-complexity, low efficiency, and inflexibility occurring in data center deployment, VMware reduces the cost of physical basic architecture, reduces the operating expenses of data centers, and improves work efficiency, flexibility, and response speed. Besides, VMware vsphere provides a host of high-availability technologies, such as HA, DRS, and FT. The latest 5.0 VMware vsphere provides powerful capacities in basic architecture virtualization and extension. 5

12 3 Storage Network Design 3 Storage Network Design About This Chapter 3.1 Reliability Design 3.2 Bandwidth Design 3.3 Load Balancing Design 3.4 Network Design 3.1 Reliability Design A SAN network design must support link redundancy, switch redundancy, controller redundancy and prevents single points of failure (SPOFs). Figure 3-1shows a typical network diagram used by OceanStor T series in a virtual environment. In the network, there are at least two data channels between each host and LUN, and the data access must pass different switches and controllers. Figure 3-1 Typical network diagram used by OceanStor series in a virtual environment 6

13 3 Storage Network Design 3.2 Bandwidth Design When designing an SAN network, you must choose the proper OceanStor T series storage systems based on the bandwidth requirements of application systems (for details about bandwidth performance, see the white papers and brochures of Huawei storage systems) and configure enough physical channels for ESX cluster to prevent the front-end links from becoming a performance bottleneck. 3.3 Load Balancing Design In a SAN network design, load balancing on controllers and links must be supported. Figure 3-1 shows the typical network which allocates LUNs equally on controllers. The proper multipathing configuration of OceanStor T series must be selected on ESX Server, and the fixed mode is recommended for VM path selection strategy to ensure link redundancy and load balancing on transmission paths. 3.4 Network Design FC network FC network is a relatively mature storage network configured on the VM platform. To establish connection between ESX servers and storage systems, HBAs must be configured on the ESX host. Each HBA has a WWN as their unique identifier. The following configurations are recommended for FC network configuration: When using an FC network, you must use the HBAs with at least two ports to ensure link redundancy. You are advised to use only the FC Zone function and to assign links of the same type to the same FC Zone to prevent cross-network effects. SCSI network Both HUAWEI OceanStor and VMware vsphere support 10GE network configuration. Because performance of a single port is improved, the number of network ports can be considerably reduced, especially for blade severs. The following configurations are recommended for ISCSI configuration: On the ESX server, the flow control function can be configured for each network port. You are advised to disable the flow control function to maximize the performance of the storage system. HUAWEI OceanStor T series and VMware vsphere 5.0 support Jumbo frame. You are advised to enable the Jumbo frame function to significantly improve network performance. (The network switch also needs to support the Jumbo frame function.) Because the IP network may conflict with the management network, you are advised to separate the iscsi network from the port management network by configuring them to different network segments or VLANs. 7

14 4 Optimizing Storage System Configuration 4 Optimizing Storage System Configuration About This Chapter 4.1 Configuration Process 4.2 Selecting Disks 4.3 Configuring RAID groups 4.4 Configuring LUN 4.5 Configuring Host Mappings 4.1 Configuration Process Figure 4-1 shows the configuration process of HUAWEI OceanStor T series, and this section describes configuration optimization from the following perspectives: Figure 4-1 Storage system configuration process Select disks Configure RAID groups Configure LUNs Configure and use LUNs on the VMware platform Configure host mappings 4.2 Selecting Disks Because OceanStor T series supports a variety of disks with different capacities and supports the mixture use of different disks, you can choose proper disks to configure the VM storage based on the requirements of your services. Table 4-1 lists the random access IOPS empirical 8

15 4 Optimizing Storage System Configuration values of some disk capacities and small data blocks, and the values can serve as references for you. Table 4-1 Disk capacity and performance Disk Type Capacity Random IOPS Application Scenario SATA 7.2k rpm 1 TB / 2 TB Backup and archiving SAS 15k rpm 300 GB / 450 GB / 600 GB SATA SSD 50 GB / 100 GB / 200 GB Video, file service, and database Database and service 4.3 Configuring RAID Groups RAID Group Levels You need configure the RAID groups based on the data features of different transactions, and Table 4-2 lists the suggestion. Table 4-2 RAID group configuration for different transactions Transaction Category Data Characteristic Configured RAID Level Configured Disk Type Sequential I/Os in transaction log disks Sequential I/Os, requiring high reliability RAID 10 SAS/FC OLTP database data Exchange Server data database RAID 10 SAS/FC Backup and archiving Large capacity RAID 5/RAID 6 SATA Java applications and Web applications File services and video applications Non-dense I/Os RAID 5 SAS/FC Random big I/Os RAID 5 SAS/FC VM boot disk Low I/O load, requiring swift response RAID 5 SAS/FC CAUTION Do not use RAID 3 except for large-block sequential reads, such as non-linear editing. Do not use RAID 0 unless otherwise specified. 9

16 4 Optimizing Storage System Configuration RAID Group Capacity Recommended configuration: The number of disks in a RAID group should range from 5 to 12. If the number is smaller than 5, the performance of the RAID group is relatively poor, followed by the requirement for more RAID groups and the increase in maintenance cost. For a RAID 5, RAID 6, or RAID 3 group, this may result in a waste of storage space. On the contrary, if the number is greater than 12, the RAID group is reconstructed when disk failure occurs. When more disks are required, the probability of multi-disk failure becomes higher and the system reliability will decrease accordingly. An odd number of disks are recommended for a RAID 5 group, and five or nine disks are preferred. An even number of disks is recommended for a RAID 6 group, and six or ten disks are preferred. Dual-disk mirroring is recommended for a RAID 10 group except for the applications that demand ultra-high reliability. Eight or twelve disks are recommended for a RAID 10 group with dual-disk mirroring Hot Spare Disk and Reliability Any disk may fail in use. Therefore, for data security, you must create hot spare disks for an OceanStor storage system and determine the number of hot spare disks based on the reliability requirement, maintenance cost, and number of RAID groups. You are advised to configure at least one hot spare disk in each disk enclosure RAID Group Performance Evaluation The random read and write performance of a RAID group can be evaluated by the random performance of a single disk, and the bandwidth of a RAID group is determined by the front-end host channels and back-end storage channels. The following formulas are used to compute the random performance of different RAID groups. You can refer to these formulas in actual application scenarios. RIOPS RAID indicates the random read IOPS performance of a RAID group.wiops RAID indicates the random write IOPS performance of a RAID group. IOPS DISK indicates the random IOPS performance of a single disk (with no notable difference between HDD random read and write performance). RMBPS RAID indicates the sequential read bandwidth performance of a RAID group. RMBPS RAID indicates the sequential write bandwidth performance of a RAID group. MBPS PATH indicates the bandwidth at the back-end channels of a RAID group. MBPS DISK indicates the sequential bandwidth performance of a single disk. N stands for the number of member disks in a RAID group (5 N 12) with the hypothesis that the front-end channels are not the performance bottleneck. RAID 0 RAID 0: a striped volume of hard disks. The sequential bandwidth is equal to the channel bandwidth performance or the total bandwidth performance of all disks. The random read and write performance is equal to the total random performance of all disks. RMBPSRAID0 = WMBPSRAID0 = MIN (MBPSPATH, MBPSDISK x N) RIOPSRAID0 = W IOPSRAID0 = IOPSDISK x N 10

17 4 Optimizing Storage System Configuration RAID 10 RAID 10: a stripe of mirrored hard disks. RMBPSRAID10 = MIN (MBPSPATH, MBPSDISK x N) WMBPSRAID10 = 1/2 x MIN (MBPSPATH, MBPSDISK x N) RIOPSRAID10 = IOPSDISK x N W IOPSRAID10 = 1/2 x IOPSDISK x N RAID 5 RAID 5: block-level striping with parity data distributed across all member disks. RMBPSRAID5 = MIN (MBPSPATH, MBPSDISK x N) WMBPSRAID5 = (N-1)/N x MIN (MBPSPATH, MBPSDISK x N) RIOPSRAID5 = IOPSDISK x N WIOPSRAID5 = 1/4 x IOPSDISK x N RAID 6 RAID 6: block-level striping with two copies of parity data distributed across all member disks. RMBPSRAID6 = MIN (MBPSPATH, MBPSDISK x N) WMBPSRAID6 = (N-2)/N x MIN (MBPSPATH, MBPSDISK x N) RIOPSRAID6 = IOPSDISK x N WIOPSRAID6 = 1/6 x IOPSDISK x N CAUTION The random IOPS formulas in the preceding formulas are not applicable to an SSD, because there is notable difference between the random read performance and random write performance of an SSD. IOPS DISK in RIOPS RAID and WIOPS RAID formulas can be replaced with RIOPS SSD and WIOPS SSD respectively for rough computation. Note that because SSDs have high random performance, the maximum IOPS of the storage system must be considered when you are computing the random performance of a RAID group. The preceding formulas are used to compute the bandwidth and IOPS of a 9-disk RAID 5 and an 8-disk RAID 10. Suppose IOPS DISK = 200, MBPS DISK = 150 MB/s, and the back-end storage uses one 4 Gbit/s SAS/FC loop, then MBPS PATH = 4 x 1000 x 1/8 x 8/10 = 400 MB/s (1/8 is the conversion from bit to byte and 8/10 is the bandwidth loss in the 8 bit/10 bit conversion). For a 9-disk RAID 5group: RMBPSRAID5 = MIN (400, 150 x 9) = 400 MB/s WMBPSRAID5 = 8/9 x MIN (400, 150 x 9) = 355 MB/s RIOPSRAID5 = 200 x 9 = 1800 WIOPSRAID5 = 1/4 x 200 x 9 = 450 For an 8-disk RAID10 group: RMBPSRAID10 = MIN (400, 150 x 8) = 400 MB/s WMBPSRAID10 = 1/2 x MIN (400, 150 x 8) = 200 MB/s RIOPSRAID10 = 200 x 8 = 1600 WIOPSRAID10 = 1/2 x 200 x 8 =

18 4 Optimizing Storage System Configuration 4.4 LUN Configuration Owning Controller The OceanStor T series storage systems use two controllers that work in the active-active mode, and each LUN has its owning controller. Under normal circumstances, the I/O operations on a LUN are processed by its owning controller, and the other controller takes over services only when the host access path or the owning controller fails. You are advised to assign the LUNs with heavy loads to both controllers equally to ensure load balancing and improve application performance Stripe Depth OceanStor T series storage systems offer multiple striping policies that bring great flexibility in application configuration. The LUN stripe depth must be determined based on the I/O size. Table 4-3 lists the typical configurations. Table 4-3 Typical stripe depths RAID Level RAID 0 RAID 5 RAID 10 Stripe Depth 256k / 512k 64k / 128 k 256k / 512k Prefetch Policies In addition, you must take the server system stripe into consideration when configuring stripes. For example, if you use ASM disks (whose default stripe depth is 1 MB) in Oracle databases, you must configure the stripe of the storage system to a value that can be exactly divided by 1 MB. The stripe depth of 256 KB is recommended for an 8-disk RAID 10, and 128 KB is recommended for a 9-disk RAID5. OceanStor T series storage systems offer four prefetch policies which can be applied to most applications. If applications have high randomicity, configure non-prefetch for them. Constant prefetch: prefetches a constant size of data from hard disks when hit fails and applies to large-block sequential read. Multiplied prefetch: prefetches a certain amount (a multiple of missed I/O amount) of data from hard disks when hit fails and applies to small-block sequential read. Intelligent prefetch: automatically determines whether to prefetch data according to the load characteristics when hit fails. OceanStor T series intelligently calculates the amount of the data to be pre-fetched. Intelligent prefetch applies to most applications. Non-prefetch: does not prefetch data and applies to random services. Intelligent prefetch is recommended for common OLTP database applications. 12

19 4 Optimizing Storage System Configuration Write-Back Policies OceanStor T series provides sound power failure protection and uses the write-back technology, which greatly shortens I/O delay and improves application performance. The write-back with mirroring mechanism applies to most applications. For those applications that demand high reliability, use write-through not write-back without mirroring for LUNs. Write-back with mirroring: After receiving a write I/O request from the host, the current controller writes this I/O request into the cache of the other controller, then writes this I/O request into its own cache, and then notifies the host that the write I/O operation is completed. The current controller flushes the cache data onto hard disks by using a policy, ensuring that the cache always has enough space for new write I/O requests. The write-back with mirroring mechanism ensures data reliability when a controller fails. Write-through: After receiving a write I/O request from the host, the current controller first writes this I/O request into its memory, then writes this I/O request into its disk, and then notifies the host that the write I/O operation is completed. The write-through mechanism applies to the application scenarios that demand ultra-high data reliability. Write-back without mirroring: After receiving a write I/O request from the host, the current controller first writes this I/O request into its memory, and then notifies the host that the write I/O operation is completed. Because the write-back without mirroring mechanism may cause data loss, it is not recommended for LUNs. Write-back with mirroring is recommended to ensure high performance and high reliability of storage systems. 4.5 Host Mappings You can map host configuration to a host or host group. You must consider the following situations when configuring mappings: 1. If such high-availability functions as HA and DRS are enabled on the VMware platform, all ESX hosts must be able to see the same storage system. Therefore, you need to add all ESX hosts to the host group and map LUNs to the host group. 2. If some host cluster functions need to use quorum disks, such as the Oracle RAC quorum disk and Microsoft cluster quorum disk, multiple ESX hosts can access the same disk. Therefore, you need to add the ESX hosts to the host group and map LUNs to the host group. 13

20 5 VM Configuration Optimization 5 VM Configuration Optimization About This Chapter 5.1 VMFS and RDM 5.2 Suggestion on VMFS Volume Configuration 5.3 Suggestion on Virtual Disk Configuration 5.4 Suggestion on RDM Configuration 5.5 Configuring I/O Queue Depth 5.6 DRS and HA Are Recommended 5.1 VMFS and RDM As a clustered file system with high performance, VMware Virtual Machine File System (VMFS) enables multiple VMs to access an integrated clustered storage pool, significantly improving resource utilization rate. By using VMFS, you can create a small number of LUNs with a big capacity and allocate the LUNs to different VMs. Figure 5-1 displays the schematic drawing of VMFS. Figure 5-1 VMFS schematic drawing 14

21 5 VM Configuration Optimization Two VMFSs are available in VMware VMs: VMFS-3 and VMFS-5. VMFS-5 optimized VMFS-3 performance, such as supporting disks with a bigger capacity. You are advised to adopt VMFS-5 to use its new features. VMFS-3 Supports up to a 2 TB disk volume. Supports master boot record (MBR) partition. Data block sizes include 1 MB, 2 MB, 4 MB, and 8 MB. The smallest sub-block size is 64 KB. The maximum number of files is The largest VMDK file size is 2 TB. Supports up to 256 LUNs. Uses the SCSI reservation mechanism to lock the whole LUN. VMFS-5 Supports up to a 60 TB disk volume, including RAW Device Mapping (RDM) disks. GUID partition table (GPT) supports a bigger capacity. Has a unified data block size of 1 MB and supports 256 GB or larger files. The sub-block size is 8 KB, occupying smaller space. Each volume supports over 100,000 files. The largest VMDK file size is 2 TB. Supports up to 256 LUNs. Uses VAAI hardware-assisted locking to reduce disk access conflicts. VMFS supports RDM.RDM can use a VM to access the physical sub-storage system, but the sub-storage system can only use FC or iscsi. Figure 5-2 displays RDM schematic drawing. VMFS provides a basic symbolic link which is used in VM configuration. When the VM needs to open an RDM device, it first opens the symbolic link. After the symbolic link file.vmdk resolves the address and finds the mapped physical device, follow-up read and write operations do not have to go through VMFS volume, and the physical device is operated by the VM. 15

22 5 VM Configuration Optimization Figure 5-2 RDM schematic drawing There is no notable difference between the performance of VMFS and RDM. For random I/O loads, VMFS and RDM have similar performance in throughput. As for sequential I/O loads, RDM has relatively better performance than VMFS. For details about the performance of VMFS and RDM, see the Performance Characterization of VMFS and RDM Using a SAN. Application scenarios of MFS and RDM: The VMFS is preferred unless otherwise specified. RDM applies to the following application scenarios: Choose RDM for P2V or V2P. Choose RDM when physical machines and VMs are used for cluster. RDM disks with physical compatibility are recommended for VMs that use Microsoft Cluster Services (MSCS). 16

23 5 VM Configuration Optimization 5.2 Suggestion on VMFS Volume Configuration Suggestion on Capacity Configuration VMFS-5 uses 1 MB data block and 8 KB sub-block and supports 256 GB or larger files, with smaller files occupying less space. The VMFS volume supports a maximal capacity of 60 TB. You are not advised to create a RAID group with an excessively large capacity, because if a physical hard disk fails, the RAID group needs to be reconstructed, and the reconstruction may affect services VMFS Volume Expansion The expansion function allows the VMFS to cross multiple LUNs. The expansion function allows the VMFS to cross multiple LUNs. In this application scenario, LUNs are arranged linearly. Space in the first LUN is used first, and space in the following LUNs will be used only when space in the first LUN is used up. As a result, the VMFS cannot balance I/O load among the LUNs to improve the application performance, but can simplify storage management and realize thin-provisioning at the application layer. If the application has a light I/O load but demands large storage space, you can create a VMFS volume across multiple LUNs; if the application has a heavy I/O load, you are advised to create multiple virtual disks for the VM and assign them to multiple VMFS volumes. Figure 5-3 VMFS volume expansion 17

24 5 VM Configuration Optimization Exclusive Volume or Shared Volume ESX administrators' top concerns may involve how many VMs a VMFS volume is assigned to and how to assign VMFS volumes to VMs of different applications. A lot of factors must be considered when determining whether to allow multiple VMs to share a big VMFS volume or allow each VM to have its own relatively smaller VMFS volume. Figure 5-4 VMFS exclusive volumes and shared volume Table 5-1lists the advantages and disadvantages of the two volume types. Choose the proper type for your configuration based on management cost, performance, and extensibility. Table 5-1 Advantages and disadvantages of exclusive VMFS and shared VMFS Exclusive VMFS Maps one VMFS volume to one VM. Poor resource utilization. Deployed in isolation. Requires more management cost. Applicable to applications with big I/Os. Shared VMFS Multiple VMs share one VMFS volume. Improved resource utilization. Easy deployment. Requires lower management cost. Resource competition may exist, compromising I/O performance. If shared storage with exclusive volumes is used, a large number of disks with high I/O workloads are configured exclusively to ensure the performance of applications with high throughput. Shared storage can be used to configure other storage systems. 18

25 5 VM Configuration Optimization 5.3 Suggestion on Virtual Disk Configuration Choosing a Virtual Disk Format The VMFS supports the following virtual disk formats: Thin: assigns space on demand. Thick: assigns a fixed amount of space. The Thick format includes the following sub-formats: Zeroed Thick: generates VMDK files with a fixed size and does not write data into disks. Eager Zeroed Thick: generates VMDK files with a fixed size and writes 0 into disks. Figure 5-5 shows that there is no notable difference between the performance of Thin and Zeroed Thick. (For details, see Performance Study of VMware vstorage Thin Provisioning.) Compared with the other two formats, Eager Zeroed Thick has better performance in sequential write and has no notable performance difference in other I/O modes. Virtual disks of each format can be expanded to a larger capacity, but no virtual disk can decrease the actual used space. Figure 5-5 Comparison of the performance of different VMFS disk formats Remarks: The figure above is from Performance Study of VMware vstorage Thin Provisioning. Zeroing: All VMFS blocks must be zeroed out before data is written into them. Post-zeroing: All VMFS blocks have been zeroed out before data is written into them. 19

26 5 VM Configuration Optimization Virtual Disk Modes 1. Choose Thin if capacity is your top concern. 2. Choose Eager Zeroed Thick if performance is your top concern. 3. If the VMFS volume is shared by different ESXs, you are advised to choose Eager Zeroed Thick to prevent faults during VM startup. VMFS supports the following virtual disk modes: Independent: The disk is not included when a snapshot is created for the VM. The Independent mode includes the following sub-modes: Persistent: The data updates are persistently saved on the virtual disk. Non-persistent: The data updates are discarded when the virtual machine is powered off or the VM snapshot is restored. Dependent: A snapshot for the virtual disk is created when a snapshot for the VM is created. In the Dependent mode, the data updates are persistently saved on the virtual disk. There is no notable virtual disk performance difference between the two modes. In the Non-persistent mode, VMware creates the REDO file in the root directory of the VM and all read operations of the virtual disk are saved in the file. If the VM is powered off or the VM snapshot is restored, this file is discarded, so this mode seriously affects virtual disk performance. The independent mode is the default mode of the system. Do not use the dependent mode unless otherwise specified SCSI Bus Sharing Methods VMware supports three SCSI bus sharing methods: None: The virtual disk cannot be shared by VMs. Virtual: The virtual disk can be shared by the VMs on the same server. Physical: The virtual disk can be shared by VMs on any server. Figure 5-6 VMware bus sharing methods 20

27 5 VM Configuration Optimization 1. If RDM volumes are used and shared by VM clusters on different servers, you are advised to choose the Physical mode for SCSI bus. 2. If VMFS volumes are used and are shared by VMs on different servers, you can choose either the Physical mode or the None mode. Use the None mode only in specific application scenarios. For details, see Disabling Simultaneous Write Protection Provided by VMFS using the Multi-Writer Flag Configuring Partition Alignment In Linux or Windows, data on a disk (or LUN) is organized in the legacy Cylinder, Head, and Sector (CHS) mode. When a partition is created, 63 sectors are reserved on the head to store the partition structure information and the main boot record, causing storage layers to be out of alignment and affecting application performance. The VMFS volume improves this storage method by reserving 64 KB data on the head when being created, but storage layers are still out of alignment with the data structure in the storage systems. Figure 5-7shows the storage structures of the VMDK, VMFS, and LUN. When the cluster, block, and chunk are out of alignment, reading/writing a cluster causes multiple blocks to be read or written. In the VMFS-5, if clusters and blocks are out of alignment, multiple block operations may be caused, resulting in read and write operations of more blocks. In the VMFS-5, the impact on the block layer is negligible, but performance may still get compromised if the clusters are out of alignment with blocks. Figure 5-7 Storage structures out of alignment VMDK file (NTFS) Cluster Cluster Cluster Cluster Cluster Cluster VMFS volume Block Block Block SAN LUN Chunk Chunk Chunk Attempt to read one disk cluster may cause read of up to three SAN chunks. Block Chunk Cluster Block Chunk Chunk Remarks: The figure above is from Recommendation for Aligning VMFS Partitions. You are advised to use the Fdisk command line tool in ESX and Linux and the Diskpart command line tool in Windows. Configure partition alignment for disks that require partition alignment, and for details about configuring partition alignment, see Recommendation for Aligning VMFS Partitions. 21

28 5 VM Configuration Optimization 5.4 Suggestion on RDM Configuration RDM supports two compatibility modes, and the two modes have no notable difference in performance. Under normal circumstances, you are advised to choose the Physical mode. Physical compatibility: allows the client to directly access the hardware. The disk is not included when a snapshot of the client is created. Virtual compatibility: allows the virtual disk to use the VMware snapshot and other advanced capabilities. 5.5 Configuring I/O Queue Depth Because there are limitations on the I/O queue depth on HBA ports, I/O queue depth of VMs, and I/O queue depth of LUNs, you are advised to perform the following configuration to improve system performance: FC HBA: A single path has a maximum I/O queue depth of 32. Run the esxcfg-module command to configure the HBA driver and set the maximum concurrence. Virtual machine: A single VM has a maximum I/O queue depth of 32 by default. Modify the depth by changing the value of the ESX advanced parameter Disk.SchedQuantum to 64. Figure 5-8 Adjusting the I/O queue depth of a VM LUN: A single LUN has a maximum I/O queue depth of 64 by default. Modify the depth by changing the value of the ESX advanced parameter Disk.SchedQuantum to 256. Figure 5-9 Modifying the I/O queue depth of a single LUN A single virtual disk or SCSI controller has a limited I/O queue depth. Create multiple virtual disks for the VM and use multiple SCSI controllers to increase the utilization ratio of storage resources. 22

29 5 VM Configuration Optimization 5.6 DRS and HA Are Recommended The VMware DRS enables the intelligent allocation of computing resources, and the VMware HA ensures the reliability of virtualized environment and service continuity. The VMware DRS provides three levels of automation: Manual: The vcenter presents suggestion on virtualization. Partially automated: VMs are automatically placed on the host and the vcenter presents suggestion on the migration of the virtual machines. Fully automated: Based on the resource usage, VMs are automatically placed on the host and automatically migrated. VMware has five migration thresholds and offers suggestion on the migration according to the selected threshold. In DRS Performance and Best Practices, VMware elaborates on how the VMware DRS improves the performance. Figure 5-10 shows how the two migration levels improve performance under an undesirable initial deployment of VMs, and Figure 5-11 shows how the two DRS migration levels improve performance under a fully balanced initial deployment of VMs. You are advised to create an ESX cluster with multiple servers and use the VMware DRS function to dynamically allocate resources. In addition, you are advised to enable the VMware HA function to ensure service reliability, performance, and continuity in the virtualized environment. Figure 5-10 Performance improvement made by DRS under an undesirable initial deployment of VMs 23

30 5 VM Configuration Optimization Figure 5-11 Performance enhancement made by DRS under a fully balanced initial deployment of VMs Remarks: The figures above are from DRS Performance and Best Practices 24

31 6 Summary 6 Summary Huawei is committed to providing customers with quality storage products and solutions, and HUAWEI OceanStor T series embodies this concept. Based on the VMware platform, HUAWEI OceanStor T series offers comprehensive solutions and best practice with high-availability, high-performance, and easy management. Drawing from the key application solutions on the VMware platform, Huawei integrates its storage systems with VMware vsphere's high availability and easy management features to offer integrated architecture. This document describes the best practice of the configuration of Huawei storage systems (based on VMware vsphere) and can serve as a reference for solution configuration. 25

32 A Glossary A Glossary Acronym ASM TCO IT DBA OLTP OLAP RAC OCR AU SAS/FC LUN RAID SAS SATA SSD SCSI ERP Full Name Automated Storage Management Total Cost of Ownership Information Technology Database Administrator Online Transaction Processing On-Line Analysis Processing Real Application Clusters Oracle Cluster Registry Allocation Unit Fibre Channel Logical Unit Number Redundant Array of Independent Disks Serial Attached SCSI Serial Advanced solid state disk Small Computer System Interface Enterprise Resource Planning 26

Cloud-Oriented Converged Storage

Cloud-Oriented Converged Storage Cloud-Oriented Converged Storage 5600, and 5800 V3 mid-range storage systems are next-generation unified storage products specifically designed for enterprise-class applications. Employing a storage operating

More information

Cloud-Oriented Converged Storage

Cloud-Oriented Converged Storage 5600, and 500 V3 Storage Systems Cloud-Oriented Converged Storage 5600, and 500 V3 mid-range storage systems are next-generation unified storage products specifically designed for enterprise-class applications.

More information

The Best Choice for SMBs

The Best Choice for SMBs The Best Choice for SMBs Huawei OceanStor 2600 V3 storage system are flash-oriented storage products specifically designed for enterprise-class applications. Employing a storage operating system built

More information

OceanStor 5300F&5500F& 5600F&5800F V5 All-Flash Storage Systems

OceanStor 5300F&5500F& 5600F&5800F V5 All-Flash Storage Systems OceanStor 5300F&5500F& 5600F&5800F V5 Huawei mid-range all-flash storage systems (OceanStor F V5 mid-range storage for short) deliver the high performance, low latency, and high scalability that are required

More information

OceanStor 6800F V5 Mission-Critical All-Flash Storage Systems

OceanStor 6800F V5 Mission-Critical All-Flash Storage Systems OceanStor 6800F V5 Mission-Critical s OceanStor 6800F V5 all-flash storage system (OceanStor 6800F V5 for short) is Huawei's next-generation mission-critical all-flash array. It has incorporated all of

More information

OceanStor T Series Configuration and Quotation Guide. Security Level:

OceanStor T Series Configuration and Quotation Guide. Security Level: OceanStor T Series Configuration and Quotation Guide Security Level: Contents 1 Product Overview 2 Configuration Instructions 3 Configuration Instances Overview of the T Series V001R005 Unified storage

More information

HUAWEI OceanStor Enterprise Unified Storage System. HyperReplication Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI OceanStor Enterprise Unified Storage System. HyperReplication Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OceanStor Enterprise Unified Storage System HyperReplication Technical White Paper Issue 01 Date 2014-03-20 HUAWEI TECHNOLOGIES CO., LTD. 2014. All rights reserved. No part of this document may

More information

Lightning Fast Rock Solid

Lightning Fast Rock Solid Lightning Fast Rock Solid OceanStor Dorado V3 all-flash storage is the ideal storage solution to handle mission-critical businesses for TM enterprises and organizations. Based on Huawei's unique FlashLink

More information

Huawei OceanStor ReplicationDirector Software Technical White Paper HUAWEI TECHNOLOGIES CO., LTD. Issue 01. Date

Huawei OceanStor ReplicationDirector Software Technical White Paper HUAWEI TECHNOLOGIES CO., LTD. Issue 01. Date Huawei OceanStor Software Issue 01 Date 2015-01-17 HUAWEI TECHNOLOGIES CO., LTD. 2015. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without

More information

EMC Business Continuity for Microsoft Applications

EMC Business Continuity for Microsoft Applications EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All

More information

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Application notes Abstract These application notes explain configuration details for using Infortrend EonStor DS Series iscsi-host

More information

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN White Paper VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN Benefits of EMC VNX for Block Integration with VMware VAAI EMC SOLUTIONS GROUP Abstract This white paper highlights the

More information

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS A detailed overview of integration points and new storage features of vsphere 5.0 with EMC VNX platforms EMC Solutions

More information

White Paper Features and Benefits of Fujitsu All-Flash Arrays for Virtualization and Consolidation ETERNUS AF S2 series

White Paper Features and Benefits of Fujitsu All-Flash Arrays for Virtualization and Consolidation ETERNUS AF S2 series White Paper Features and Benefits of Fujitsu All-Flash Arrays for Virtualization and Consolidation Fujitsu All-Flash Arrays are extremely effective tools when virtualization is used for server consolidation.

More information

White Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft

White Paper. A System for  Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS

More information

The Fastest Scale-Out NAS

The Fastest Scale-Out NAS The Fastest Scale-Out NAS The features a symmetric distributed architecture that delivers superior performance, extensive scale-out capabilities, and a super-large single file system providing shared storage

More information

Best Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3. Huawei Enterprise BG, IT Storage Solution Dept Version 1.

Best Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3. Huawei Enterprise BG, IT Storage Solution Dept Version 1. Best Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3 Huawei Enterprise BG, IT Storage Solution Dept 2017-7-31 Version 1.0 Contents 1 About This Document... 3 1.1 Overview... 3 1.2 Purpose...

More information

VMware vsphere with ESX 4.1 and vcenter 4.1

VMware vsphere with ESX 4.1 and vcenter 4.1 QWERTYUIOP{ Overview VMware vsphere with ESX 4.1 and vcenter 4.1 This powerful 5-day class is an intense introduction to virtualization using VMware s vsphere 4.1 including VMware ESX 4.1 and vcenter.

More information

The Oracle Database Appliance I/O and Performance Architecture

The Oracle Database Appliance I/O and Performance Architecture Simple Reliable Affordable The Oracle Database Appliance I/O and Performance Architecture Tammy Bednar, Sr. Principal Product Manager, ODA 1 Copyright 2012, Oracle and/or its affiliates. All rights reserved.

More information

Best Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager. Huawei Enterprise BG, IT Storage Solution Dept Version 1.

Best Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager. Huawei Enterprise BG, IT Storage Solution Dept Version 1. Best Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager Huawei Enterprise BG, IT Storage Solution Dept 2017-8-20 Version 1.0 Contents 1 About This Document... 3 1.1 Overview...

More information

Assessing performance in HP LeftHand SANs

Assessing performance in HP LeftHand SANs Assessing performance in HP LeftHand SANs HP LeftHand Starter, Virtualization, and Multi-Site SANs deliver reliable, scalable, and predictable performance White paper Introduction... 2 The advantages of

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (FC/iSCSI) enables SAN tiering Balanced performance well-suited for

More information

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

EMC Integrated Infrastructure for VMware. Business Continuity

EMC Integrated Infrastructure for VMware. Business Continuity EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.

More information

UltraPath Technical White Paper

UltraPath Technical White Paper HUAWEI OceanStor Enterprise Unified Storage System Issue 01 Date 2014-04-02 HUAWEI TECHNOLOGIES CO, LTD Copyright Huawei Technologies Co, Ltd 2014 All rights reserved No part of this document may be reproduced

More information

Data center requirements

Data center requirements Prerequisites, page 1 Data center workflow, page 2 Determine data center requirements, page 2 Gather data for initial data center planning, page 2 Determine the data center deployment model, page 3 Determine

More information

Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems

Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems NETAPP TECHNICAL REPORT Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems A Performance Comparison Study of FC, iscsi, and NFS Protocols Jack McLeod, NetApp

More information

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage A Dell Technical White Paper Dell Database Engineering Solutions Anthony Fernandez April 2010 THIS

More information

5300F, 5500F, 5600F, 5800F, 6800F,

5300F, 5500F, 5600F, 5800F, 6800F, Huawei OceanStor 5300F, 5500F, 5600F, 5800F, 6800F, Issue 01 Date 2017-11-30 HUAWEI TECHNOLOGIES CO., LTD. 2017. All rights reserved. No part of this document may be reproduced or transmitted in any form

More information

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results Dell Fluid Data solutions Powerful self-optimized enterprise storage Dell Compellent Storage Center: Designed for business results The Dell difference: Efficiency designed to drive down your total cost

More information

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE White Paper EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE EMC XtremSF, EMC XtremCache, EMC Symmetrix VMAX and Symmetrix VMAX 10K, XtremSF and XtremCache dramatically improve Oracle performance Symmetrix

More information

EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using FCP and NFS. Reference Architecture

EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution. Enabled by EMC Celerra and Linux using FCP and NFS. Reference Architecture EMC Unified Storage for Oracle Database 11g/10g Virtualized Solution Enabled by EMC Celerra and Linux using FCP and NFS Reference Architecture Copyright 2009 EMC Corporation. All rights reserved. Published

More information

Surveillance Dell EMC Storage with Digifort Enterprise

Surveillance Dell EMC Storage with Digifort Enterprise Surveillance Dell EMC Storage with Digifort Enterprise Configuration Guide H15230 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published August 2016 Dell believes the

More information

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure Nutanix Tech Note Virtualizing Microsoft Applications on Web-Scale Infrastructure The increase in virtualization of critical applications has brought significant attention to compute and storage infrastructure.

More information

Dell EMC SAN Storage with Video Management Systems

Dell EMC SAN Storage with Video Management Systems Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for

More information

Huawei FusionCloud Desktop Solution 5.1 Resource Reuse Technical White Paper HUAWEI TECHNOLOGIES CO., LTD. Issue 01.

Huawei FusionCloud Desktop Solution 5.1 Resource Reuse Technical White Paper HUAWEI TECHNOLOGIES CO., LTD. Issue 01. Huawei FusionCloud Desktop Solution 5.1 Resource Reuse Technical White Paper Issue 01 Date 2014-03-26 HUAWEI TECHNOLOGIES CO., LTD. 2014. All rights reserved. No part of this document may be reproduced

More information

HUAWEI Tecal X8000 High-Density Rack Server

HUAWEI Tecal X8000 High-Density Rack Server HUAWEI Tecal X8000 High-Density Rack Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. HUAWEI Tecal X8000 High-Density Rack Server (X8000) High density and innovative architecture

More information

NEC M100 Frequently Asked Questions September, 2011

NEC M100 Frequently Asked Questions September, 2011 What RAID levels are supported in the M100? 1,5,6,10,50,60,Triple Mirror What is the power consumption of M100 vs. D4? The M100 consumes 26% less energy. The D4-30 Base Unit (w/ 3.5" SAS15K x 12) consumes

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

Cisco HyperFlex All-Flash Systems for Oracle Real Application Clusters Reference Architecture

Cisco HyperFlex All-Flash Systems for Oracle Real Application Clusters Reference Architecture Cisco HyperFlex All-Flash Systems for Oracle Real Application Clusters Reference Architecture 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of

More information

SAP HANA. HA and DR Guide. Issue 03 Date HUAWEI TECHNOLOGIES CO., LTD.

SAP HANA. HA and DR Guide. Issue 03 Date HUAWEI TECHNOLOGIES CO., LTD. Issue 03 Date 2018-05-23 HUAWEI TECHNOLOGIES CO., LTD. Copyright Huawei Technologies Co., Ltd. 2019. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any

More information

VMware vsphere VMFS First Published On: Last Updated On:

VMware vsphere VMFS First Published On: Last Updated On: First Published On: 10-24-2017 Last Updated On: 10-24-2017 1 Table of Contents 1. Introduction 1.1.Introduction 2. Background 2.1.Background 3. VMFS Technical Overview 3.1.VMFS Technical Overview 4. Features

More information

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Best practices Roland Mueller IBM Systems and Technology Group ISV Enablement April 2012 Copyright IBM Corporation, 2012

More information

Stellar performance for a virtualized world

Stellar performance for a virtualized world IBM Systems and Technology IBM System Storage Stellar performance for a virtualized world IBM storage systems leverage VMware technology 2 Stellar performance for a virtualized world Highlights Leverages

More information

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3. EMC Backup and Recovery for Microsoft Exchange 2007 SP1 Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.5 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

Recommendations for Aligning VMFS Partitions

Recommendations for Aligning VMFS Partitions VMWARE PERFORMANCE STUDY VMware ESX Server 3.0 Recommendations for Aligning VMFS Partitions Partition alignment is a known issue in physical file systems, and its remedy is well-documented. The goal of

More information

VMware VAAI Integration. VMware vsphere 5.0 VAAI primitive integration and performance validation with Dell Compellent Storage Center 6.

VMware VAAI Integration. VMware vsphere 5.0 VAAI primitive integration and performance validation with Dell Compellent Storage Center 6. VMware vsphere 5.0 VAAI primitive integration and performance validation with Dell Compellent Storage Center 6.0 Document revision Date Revision Comments /9/0 A Initial Draft THIS GUIDE IS FOR INFORMATIONAL

More information

VMware vsphere 5.5 Professional Bootcamp

VMware vsphere 5.5 Professional Bootcamp VMware vsphere 5.5 Professional Bootcamp Course Overview Course Objectives Cont. VMware vsphere 5.5 Professional Bootcamp is our most popular proprietary 5 Day course with more hands-on labs (100+) and

More information

"Charting the Course... VMware vsphere 6.7 Boot Camp. Course Summary

Charting the Course... VMware vsphere 6.7 Boot Camp. Course Summary Description Course Summary This powerful 5-day, 10 hour per day extended hours class is an intensive introduction to VMware vsphere including VMware ESXi 6.7 and vcenter 6.7. This course has been completely

More information

Chapter 10: Mass-Storage Systems

Chapter 10: Mass-Storage Systems Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space

More information

DELL EMC UNITY: BEST PRACTICES GUIDE

DELL EMC UNITY: BEST PRACTICES GUIDE DELL EMC UNITY: BEST PRACTICES GUIDE Best Practices for Performance and Availability Unity OE 4.5 ABSTRACT This white paper provides recommended best practice guidelines for installing and configuring

More information

Huawei OceanStor 2200 V3 and 2600 V3 Storage Systems. Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Huawei OceanStor 2200 V3 and 2600 V3 Storage Systems. Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD. Systems Technical White Paper Issue 01 Date 2016-04-30 HUAWEI TECHNOLOGIES CO., LTD. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without

More information

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp Agenda The Landscape has Changed New Customer Requirements The Market has Begun to Move Comparing Performance Results Storage

More information

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1 Copyright 2011, 2012 EMC Corporation. All rights reserved. Published March, 2012 EMC believes the information in this publication

More information

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition

Chapter 10: Mass-Storage Systems. Operating System Concepts 9 th Edition Chapter 10: Mass-Storage Systems Silberschatz, Galvin and Gagne 2013 Chapter 10: Mass-Storage Systems Overview of Mass Storage Structure Disk Structure Disk Attachment Disk Scheduling Disk Management Swap-Space

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

Surveillance Dell EMC Storage with FLIR Latitude

Surveillance Dell EMC Storage with FLIR Latitude Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information

More information

VMware vsphere with ESX 4 and vcenter

VMware vsphere with ESX 4 and vcenter VMware vsphere with ESX 4 and vcenter This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere suite including VMware ESX 4 and vcenter. Assuming no prior virtualization

More information

Configuring and Managing Virtual Storage

Configuring and Managing Virtual Storage Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

Microsoft Office SharePoint Server 2007

Microsoft Office SharePoint Server 2007 Microsoft Office SharePoint Server 2007 Enabled by EMC Celerra Unified Storage and Microsoft Hyper-V Reference Architecture Copyright 2010 EMC Corporation. All rights reserved. Published May, 2010 EMC

More information

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved. VMware Virtual SAN Technical Walkthrough Massimiliano Moschini Brand Specialist VCI - vexpert 2014 VMware Inc. All rights reserved. VMware Storage Innovations VI 3.x VMFS Snapshots Storage vmotion NAS

More information

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Configuration Guide H14001 REV 1.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2015 Dell believes

More information

Virtualization of the MS Exchange Server Environment

Virtualization of the MS Exchange Server Environment MS Exchange Server Acceleration Maximizing Users in a Virtualized Environment with Flash-Powered Consolidation Allon Cohen, PhD OCZ Technology Group Introduction Microsoft (MS) Exchange Server is one of

More information

Infortrend VMware Solutions

Infortrend VMware Solutions Infortrend VMware Solutions Best Practice Version: 1.2 Updated: Nov., 2017 Abstract: This document describes the best practices for using Infortrend storage in VMware environment. Infortrend storage provides

More information

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow

More information

Increase Scalability for Virtual Desktops with EMC Symmetrix FAST VP and VMware VAAI

Increase Scalability for Virtual Desktops with EMC Symmetrix FAST VP and VMware VAAI White Paper with EMC Symmetrix FAST VP and VMware VAAI EMC GLOBAL SOLUTIONS Abstract This white paper demonstrates how an EMC Symmetrix VMAX running Enginuity 5875 can be used to provide the storage resources

More information

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS

Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and VMware s Distributed

More information

VX3000-E Unified Network Storage

VX3000-E Unified Network Storage Datasheet VX3000-E Unified Network Storage Overview VX3000-E storage, with high performance, high reliability, high available, high density, high scalability and high usability, is a new-generation unified

More information

Storage Solutions for VMware: InfiniBox. White Paper

Storage Solutions for VMware: InfiniBox. White Paper Storage Solutions for VMware: InfiniBox White Paper Abstract The integration between infrastructure and applications can drive greater flexibility and speed in helping businesses to be competitive and

More information

Huawei OceanStor 9000 Scale-Out NAS. Technical White Paper. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD.

Huawei OceanStor 9000 Scale-Out NAS. Technical White Paper. Issue 05. Date HUAWEI TECHNOLOGIES CO., LTD. Issue 05 Date 2017-01-20 HUAWEI TECHNOLOGIES CO., LTD. 2017. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of

More information

VMware vsphere 6.5 Boot Camp

VMware vsphere 6.5 Boot Camp Course Name Format Course Books 5-day, 10 hour/day instructor led training 724 pg Study Guide fully annotated with slide notes 243 pg Lab Guide with detailed steps for completing all labs 145 pg Boot Camp

More information

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise Virtualization with VMware ESX and VirtualCenter SMB to Enterprise This class is an intense, five-day introduction to virtualization using VMware s immensely popular Virtual Infrastructure suite including

More information

SvSAN Data Sheet - StorMagic

SvSAN Data Sheet - StorMagic SvSAN Data Sheet - StorMagic A Virtual SAN for distributed multi-site environments StorMagic SvSAN is a software storage solution that enables enterprises to eliminate downtime of business critical applications

More information

Automated Storage Tiering on Infortrend s ESVA Storage Systems

Automated Storage Tiering on Infortrend s ESVA Storage Systems Automated Storage Tiering on Infortrend s ESVA Storage Systems White paper Abstract This white paper introduces automated storage tiering on Infortrend s ESVA storage arrays. Storage tiering can generate

More information

HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers

HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers Technical White Paper HUAWEI SAN Storage Host Connectivity Guide for VMware ESXi Servers OceanStor Storage VMware Huawei Technologies Co., Ltd. 2017-09-28 Copyright Huawei Technologies Co., Ltd. 2017.

More information

How to Speed up Database Applications with a Purpose-Built SSD Storage Solution

How to Speed up Database Applications with a Purpose-Built SSD Storage Solution How to Speed up Database Applications with a Purpose-Built SSD Storage Solution SAN Accessible Storage Array Speeds Applications by up to 25x Introduction Whether deployed in manufacturing, finance, web

More information

Optimizing the Data Center with an End to End Solutions Approach

Optimizing the Data Center with an End to End Solutions Approach Optimizing the Data Center with an End to End Solutions Approach Adam Roberts Chief Solutions Architect, Director of Technical Marketing ESS SanDisk Corporation Flash Memory Summit 11-13 August 2015 August

More information

SSD Architecture Considerations for a Spectrum of Enterprise Applications. Alan Fitzgerald, VP and CTO SMART Modular Technologies

SSD Architecture Considerations for a Spectrum of Enterprise Applications. Alan Fitzgerald, VP and CTO SMART Modular Technologies SSD Architecture Considerations for a Spectrum of Enterprise Applications Alan Fitzgerald, VP and CTO SMART Modular Technologies Introduction Today s SSD delivers form-fit-function compatible solid-state

More information

Using EMC FAST with SAP on EMC Unified Storage

Using EMC FAST with SAP on EMC Unified Storage Using EMC FAST with SAP on EMC Unified Storage Applied Technology Abstract This white paper examines the performance considerations of placing SAP applications on FAST-enabled EMC unified storage. It also

More information

UCS Invicta: A New Generation of Storage Performance. Mazen Abou Najm DC Consulting Systems Engineer

UCS Invicta: A New Generation of Storage Performance. Mazen Abou Najm DC Consulting Systems Engineer UCS Invicta: A New Generation of Storage Performance Mazen Abou Najm DC Consulting Systems Engineer HDDs Aren t Designed For High Performance Disk 101 Can t spin faster (200 IOPS/Drive) Can t seek faster

More information

Functional Testing of SQL Server on Kaminario K2 Storage

Functional Testing of SQL Server on Kaminario K2 Storage Functional Testing of SQL Server on Kaminario K2 Storage September 2016 TABLE OF CONTENTS 2 3 4 11 12 14 Executive Summary Introduction to Kaminario K2 Functionality Tests for SQL Server Summary Appendix:

More information

VMware vsphere 5.5 Advanced Administration

VMware vsphere 5.5 Advanced Administration Format 4-day instructor led training Course Books 630+ pg Study Guide with slide notes 180+ pg Lab Guide with detailed steps for completing labs vsphere Version This class covers VMware vsphere 5.5 including

More information

A Dell Technical White Paper Dell Virtualization Solutions Engineering

A Dell Technical White Paper Dell Virtualization Solutions Engineering Dell vstart 0v and vstart 0v Solution Overview A Dell Technical White Paper Dell Virtualization Solutions Engineering vstart 0v and vstart 0v Solution Overview THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES

More information

EMC CLARiiON Backup Storage Solutions

EMC CLARiiON Backup Storage Solutions Engineering White Paper Backup-to-Disk Guide with Computer Associates BrightStor ARCserve Backup Abstract This white paper describes how to configure EMC CLARiiON CX series storage systems with Computer

More information

Huawei OceanStor Dorado V3 All Flash Storage Reference Architecture for Performance Optimization and Data Migration of VMware Horizon View

Huawei OceanStor Dorado V3 All Flash Storage Reference Architecture for Performance Optimization and Data Migration of VMware Horizon View Huawei OceanStor Dorado V3 All Flash Storage Reference Architecture for Performance Optimization and Data Migration of VMware Horizon View OceanStor Dorado V3 series products (Dorado V3 for short) are

More information

IBM System Storage DCS3700

IBM System Storage DCS3700 IBM System Storage DCS3700 Maximize performance, scalability and storage density at an affordable price Highlights Gain fast, highly dense storage capabilities at an affordable price Deliver simplified

More information

SAP Applications on IBM XIV System Storage

SAP Applications on IBM XIV System Storage SAP Applications on IBM XIV System Storage Hugh Wason IBM Storage Product Manager SAP Storage Market - Why is it Important? Storage Market for SAP is estimated at $2Bn+ SAP BW storage sizes double every

More information

Storage Optimization with Oracle Database 11g

Storage Optimization with Oracle Database 11g Storage Optimization with Oracle Database 11g Terabytes of Data Reduce Storage Costs by Factor of 10x Data Growth Continues to Outpace Budget Growth Rate of Database Growth 1000 800 600 400 200 1998 2000

More information

EonStor DS 3000 Series

EonStor DS 3000 Series EonStor DS 000 Series High speed flexible storage delivers robust reliability and management Turbo charged storage DS 000T Gen Up to 1.M IOPS and,00 MBps throughput High IOPS solutions ideal for database

More information

V. Mass Storage Systems

V. Mass Storage Systems TDIU25: Operating Systems V. Mass Storage Systems SGG9: chapter 12 o Mass storage: Hard disks, structure, scheduling, RAID Copyright Notice: The lecture notes are mainly based on modifications of the slides

More information

Performance Testing of SQL Server on Kaminario K2 Storage

Performance Testing of SQL Server on Kaminario K2 Storage Performance Testing of SQL Server on Kaminario K2 Storage September 2016 TABLE OF CONTENTS 2 3 5 14 15 17 Executive Summary Introduction to Kaminario K2 Performance Tests for SQL Server Summary Appendix:

More information

By the end of the class, attendees will have learned the skills, and best practices of virtualization. Attendees

By the end of the class, attendees will have learned the skills, and best practices of virtualization. Attendees Course Name Format Course Books 5-day instructor led training 735 pg Study Guide fully annotated with slide notes 244 pg Lab Guide with detailed steps for completing all labs vsphere Version Covers uses

More information

VX1800 Series Unified Network Storage

VX1800 Series Unified Network Storage Datasheet VX1800 Series Unified Network Storage Overview VX1800 series storage, with high performance, high reliability, high density, high scalability and high usability, is a new-generation unified network

More information

HP P6000 Enterprise Virtual Array

HP P6000 Enterprise Virtual Array HP P6000 Enterprise Virtual Array The HP P6000 Enterprise Virtual Array (P6000 EVA) is an enterprise class virtual storage array family for midsized organizations at an affordable price. With built in

More information

S Series Switch. Cisco HSRP Replacement. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

S Series Switch. Cisco HSRP Replacement. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD. Cisco HSRP Replacement Issue 01 Date 2013-08-05 HUAWEI TECHNOLOGIES CO., LTD. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior

More information

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4 W H I T E P A P E R Comparison of Storage Protocol Performance in VMware vsphere 4 Table of Contents Introduction................................................................... 3 Executive Summary............................................................

More information

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March IOmark- VM HP MSA P2000 Test Report: VM- 140304-2a Test Report Date: 4, March 2014 Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VM, IOmark- VDI, VDI- IOmark, and IOmark are trademarks

More information

Huawei MZ110 NIC V100R001. White Paper. Issue 07 Date HUAWEI TECHNOLOGIES CO., LTD.

Huawei MZ110 NIC V100R001. White Paper. Issue 07 Date HUAWEI TECHNOLOGIES CO., LTD. V100R001 Issue 07 Date 2016-11-21 HUAWEI TECHNOLOGIES CO., LTD. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent

More information

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide.   support.dell.com VMware Infrastructure 3.0.2 Update 1 for Dell PowerEdge Systems Deployment Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

Technical Note P/N REV A01 March 29, 2007

Technical Note P/N REV A01 March 29, 2007 EMC Symmetrix DMX-3 Best Practices Technical Note P/N 300-004-800 REV A01 March 29, 2007 This technical note contains information on these topics: Executive summary... 2 Introduction... 2 Tiered storage...

More information