E55C. Communication Industrial and Commercial. PLAN+ Modem. User Manual

Size: px
Start display at page:

Download "E55C. Communication Industrial and Commercial. PLAN+ Modem. User Manual"

Transcription

1 Communication Industrial and Commercial PLAN+ Modem E55C User Manual Date: File name: D E55C PLAN Plus Modem User Manual en.docx Landis+Gyr D en a

2 2/22 Revision history Revision history Version Date Comments a First edition Nothing in this document shall be construed as a representation or guarantee in respect of the performance, quality or durability of the specified product. Landis+Gyr accepts no liability whatsoever in respect of the specified product under or in relation to this document. Subject to change without notice. Landis+Gyr D en a E55C PLAN+ Modem User Manual

3 About this document 3/22 About this document Range of validity Purpose Target group Reference documents Typographical conventions The present user manual applies to the E55C PLAN+ modem. This user manual contains instructions and information related to the installation, operation, exchange, etc. of the E55C PLAN+ modem. This includes: Information about the characteristics, construction and function of the E55C PLAN+ modem. Information about possible dangers and how they can be avoided. Detailed descriptions of all tasks performed by the utility throughout the entire life-cycle of the E55C PLAN+ modem (installation, operation, maintenance, shutting down and disposal). This user manual is intended for technically qualified personnel of energy supply companies responsible for system planning, installation and commissioning, operation, maintenance, decommissioning and disposal of meters and associated devices. The following documents contain additional information about the E55C PLAN+ modem: Technical Data E55C PLAN+ modem, D Functional Description E55C PLAN+ modem, D The following typographical conventions are used in this document: Font Bold Italics Description Font style used for menu items and buttons in the user interface and for keyboard keys. Font style used for captions and new terminology. Symbol for additional information, hints and other important notifications. Terms and abbreviations A list of terms and abbreviations used in this document is available at the end of this document. D en a E55C PLAN+ Modem User Manual Landis+Gyr

4 4/22 Table of contents Table of contents Revision history... 2 About this document... 3 Table of contents Safety Safety information Responsibilities Safety regulations Device description Scope of application Characteristics Functions Mechanical description Overview Faceplate Connections Installation/de-installation Preparing the E55C PLAN+ modem for installation Fitting and connecting the E55C PLAN+ modem Commissioning and functional check Removing/exchanging the E55C PLAN+ modem Operation LED "PLC Tx/Rx" in normal operating mode LED "RS485 Tx/Rx" in normal operating mode LED "PLC Registered" in normal operating mode Configuration mode Maintenance Service Troubleshooting Repairing the E55C PLAN+ modem Decommissioning and disposal Terms and abbreviations Index Landis+Gyr D en a E55C PLAN+ Modem User Manual

5 Safety 5/22 1 Safety 1.1 Safety information The following symbols are used to draw your attention to the relevant danger level, i.e. the severity and probability of any danger, in the individual sections of this document. Warning Used to indicate a dangerous situation that could cause bodily injury or death. Caution Used to indicate a situation/action that could result in material damage or loss of data. Note Used to indicate general guidelines and other useful information. 1.2 Responsibilities In addition to the danger level, safety information also describes the type and source of the danger, its possible consequences and measures for avoiding the danger. The owner of the meters usually the utility company is responsible for assuring that all persons engaged in working with meters: Have read and understood the relevant sections of the user manual. Are appropriately qualified for the work to be performed. Strictly observe the safety regulations (laid down in section 1.3) and the operating instructions as specified in the individual sections. In particular, the owner of the meters bears responsibility for the protection of persons, prevention of material damage and the training of personnel. For this purpose, Landis+Gyr provides training on a variety of products and solutions. Please contact your local Landis+Gyr representative if interested. D en a E55C PLAN+ Modem User Manual Landis+Gyr

6 6/22 Safety 1.3 Safety regulations The following safety regulations must be observed at all times: The device connections must be disconnected from all voltage sources during installation or when opening. Contact with live parts can be fatal. The main fuses should, therefore, be removed and kept in a safe place until the work is completed so that other persons cannot replace them unnoticed. Local safety regulations must be observed. Only technically qualified and appropriately trained personnel are authorised to install the devices. Only appropriate tools shall be used for the job. This means, e.g. that the screwdriver must be of the correct size for the screws, and the handle of the screwdriver must be insulated. The devices must be held securely during installation. They can cause injuries if dropped. Devices that have been dropped must not be installed, even if no damage is apparent, but must be returned to the service and repair department (or the manufacturer) for testing. Internal damage may result in malfunctions or short-circuits. The devices must never be cleaned under running water or with compressed air. Water ingress can cause short-circuits. Landis+Gyr D en a E55C PLAN+ Modem User Manual

7 Device description 7/22 2 Device description 2.1 Scope of application 2.2 Characteristics E55C PLAN+ modems provide PLC (Power Line Carrier) communication between the connected meter and a central AMM system. The E55C PLAN+ modem is intended for the use with the following Landis+Gyr meters: E650 (ZxD) meters, series 3 E650 (ZxD) meters, series 2 with firmware B23 or B24 E550 (ZxG) meter, series 2 It is preferably installed on a specific meter terminal cover (part number ) with the corresponding adapter. In exceptional cases it can also be wall mounted using 3 screws or a DIN-rail. The E55C PLAN+ modem has the following basic characteristics: PLC interface for remote communication between the connected E550 or E650 meter and a central AMM system (PLAN transmission rate 1200 or 2400 bits per second) via a data concentrator such as the DC450. If no meter is connected, the device will operate as a PLC repeater. RS485 interface for local communication with an E550 or E650 meter. 3 LEDs as status indications 1 push button for basic configurations 2.3 Functions PLAN+ modem A functional description of the E55C PLAN+ modem is provided separately. The following main functions are briefly summarised below: The E55C includes a complete modem implementing both the physical and link layer of the PLAN+ standard as defined in IEC The modem allows transmission speeds of 1200 bits per second and 2400 bits per second using the distribution lines as the communication media in low voltage networks using spread frequency shift keying (S_FSK). RS485 interface The RS485 interface is standardized according to ISO And can be used to connect to a single meter with an RS485 interface using the included cable. The E55C is the master of the bus and the meter is the slave. Only a single meter can be supported by one E55C PLAN+ Modem. Protocol gateway The E55C implements all protocol conversions necessary to allow logical name addressing of the meter that only supports short name addressing at the COSEM application layer level. The logical name addressing is used on the PLAN+ network while the short name addressing is used on the RS485 interface. In addition, the E55C encapsulates DLMS messages in HDLC frames for presentation to the meter on the RS485 interface. D en a E55C PLAN+ Modem User Manual Landis+Gyr

8 8/22 Mechanical description 3 Mechanical description 3.1 Overview The E55C PLAN+ modem is a unit complete in itself with its own plastic case. The cover is transparent. The mains connections and the interface connections to the meter are situated under the modem terminal cover Fig. 1: E55C PLAN+ modem with and without terminal cover 1 Adapter (used to attach to meter terminal cover) 2 Plastic case 3 Transparent cover 4 LED "PLC Tx/Rx" (bicolour: red and green) 5 LED "RS485 Tx/Rx" (bicolour: red and green) 6 LED "PLC Registered" (green) 7 Sealable terminal cover screw 8 Terminal cover 9 Push button 10 PLC/Mains terminal screws 11 DIN release latch 3.2 Faceplate The transparent cover is labelled with some basic information. This includes the Landis+Gyr logo, product name, CE mark, double isolated marking, line voltage, line frequency, firmware version and serial number. Landis+Gyr D en a E55C PLAN+ Modem User Manual

9 Mechanical description 9/ Connections 1 2 Fig. 2 Connections 1 PLC/Mains connection (screw tightened terminals) 2 RS485 interface (RJ12 socket) PLC/Mains connection RS485 interface The PLC/Mains connection of the E55C PLAN+ modem is made via the two screw tightened terminals on the front side of the case (under the terminal cover). The PLC/Mains connection line is polarity independent, i.e. it does not matter which wire of the cable (phase and neutral) is connected to which screw tightened terminal. The RS485 connection of the E55C PLAN+ modem to the meter is made via an RJ12 socket with the following pin assignment: Pin No. Signal 1 GND 2 UP (Data a) 3 UN (Data b) 4 UN (Data b) 5 UP (Data a) 6 GND The pins of the RJ12 socket are numbered as follows: 1 6 Fig. 3 Pin numbering of RJ12 socket D en a E55C PLAN+ Modem User Manual Landis+Gyr

10 10/22 Installation/de-installation 4 Installation/de-installation The preferred method to install the E55C PLAN+ modem is to mount the modem on a specific meter terminal cover with the provided adapter. In cases where there is no room to mount the modem on top of the terminal cover, the modem can also be wall mounted using 3 screws or a DIN-rail mounted (not described in this user manual). This is done by detaching the adapter plate by pulling the DIN release latch fully. Wall mounting and DINrail mounting is the typical method for using the E55C PLAN+ modem as a PLAN repeater. 4.1 Preparing the E55C PLAN+ modem for installation Before starting work check that the materials required are all present: E55C PLAN+ modem Adapter RJ12 connection cable FTT4/5 for RCR meter terminal cover (part number ordered as part of meter or as a separate part) 1. Cut two connecting wires (not included) to the required length (approx. 250 mm) and strip their ends by approximately 4 mm. If stranded wire is used instead of a wire, it has to be provided with ferrules. The length of the wire may vary if it is installed using wall mounting or DIN-rail mount. Wires of less than 2.5 mm 2 can be used. 2. Remove the small terminal cover of the E55C by turning the plastic screw counter-clockwise. 4.2 Fitting and connecting the E55C PLAN+ modem Disconnect the meter from mains before fitting and connecting the E55C PLAN+ modem In order to avoid hazardous electric shocks, ensure there is no voltage applied to the meter when fitting and connecting the E55C PLAN+ modem. Fit the E55C PLAN+ modem as follows: 1. Ensure that the meter is disconnected from mains. 2. Remove the utility seals on the meter terminal cover. 3. Remove the meter terminal cover. 4. If the E55C PLAN+ modem is used with an E550 (ZxG) meter, insert the two connecting wires in the appropriate phase and neutral screw tightened terminals of the E550 meter (voltage outputs on top row of terminals, terminal numbers see connection diagram) and carefully tighten the terminal screws (torque max. 0.6 Nm). If the E55C PLAN+ modem is used with an E650 (ZxD) meter, insert the two connecting wires in the appropriate phase and neutral screwless spring-loaded terminals of the E650 meter (voltage outputs on centre row of terminals, terminal numbers see connection diagram) as shown in Fig. 4 below. Landis+Gyr D en a E55C PLAN+ Modem User Manual

11 Installation/de-installation 11/22 ca. 4 mm Fig. 4 A B C E55C mains connection to an E650 meter 5. Insert one end of the RJ12 connection cable in the RS485 RJ12 socket of the meter until the connector engages. 6. Feed the wires and the RJ12 cable through the big hole of the FTT4/5 terminal cover. 7. Put the terminal cover on the meter and tighten the two silver screws firmly (torque max. 3 Nm). 8. Hold the E55C to the terminal cover while feeding through the wires and the RJ12 cable through the meter terminal cover with E55C. 9. Fasten the three 15.9 mm screws firmly to secure the E55C to the terminal cover. 10. Insert the free end of the RJ12 connection cable in the RJ12 socket of the E55C PLAN+ modem until the connector engages. 11. Insert the free end of the wires into the terminals of the E55C. For wires with small conductor cross-sections the connecting wire must be placed carefully in the middle of the terminal, so that it cannot move sideways when tightening the terminal screws. When tightening, ensure that the connecting line remains between the copper inside the terminal and the screw. 12. Check the installation as described in section 4.3 "Commissioning and functional check". 4.3 Commissioning and functional check The installed E55C PLAN+ modem should be put into service and checked when used with a meter as follows: 1. Insert the main fuses removed before installation. The meter and the E55C PLAN+ modem should be powered up. 2. Check whether the LED "RS485 Tx/Rx" on the E55C PLAN+ modem is either on (steady green) or is blinking green or red (in case a communication between meter and E55C PLAN+ modem is taking place). If the LED "RS485 Tx/Rx" remains off, the RS485 connection is not properly connected or the RS485 interface on the meter is not configured properly. 3. If necessary, press and hold down the push button on the E55C PLAN+ modem for longer than 3 seconds to enter the configuration mode. Cycle through all possible combinations of repeater modes or transmission rates. LED "RS485 Tx/Rx" indicates the repeater status value setting: - Red = Always repeater - Green = Dynamic repeater - Off = Never repeater D en a E55C PLAN+ Modem User Manual Landis+Gyr

12 12/22 Installation/de-installation LED "PLC Registered" indicates the transmission rate setting: - Green = 2400 bits per second - Off = 1200 bits per second 4. Long press the push button on the E55C PLAN+ modem (> 3 s) to save the setting and exit the configuration mode. 5. Normally, the E55C is installed on a network with PLC concentrator that has been commissioned. Depending on the configuration of the concentrator, the time that it takes for a metering point to be discovered by the concentrator can vary drastically. Typical setting can mean that an installer would have to wait up to one hour before the metering point is discovered. If a definite confirmation of communication is needed before leaving the site, the installer will have to contact the Head End System to initiate a discovery process. Alternatively, some installers simply assume that the installation is correct and that only a small percentage of metering points will need further debugging work. If the concentrator is searching for new meters, check that the LED "PLC Registered" is either blinking (locked, unregistered) or on (locked and registered). If the LED "PLC Registered" remains off, the E55C PLAN+ modem is unlocked and unregistered. PLC concentrators must have been installed Communication check can be performed only if PLC concentrators have already been installed on the network. A PLC concentrator automatically identifies devices operating in its communication area and adds them to the concentrator's topology in the system and automatic reading can begin. See concentrator and system documentation for more information. 6. If the commissioning and functional checks including the communication check are successful, mount the E55C PLAN+ modem small terminal cover by turning the plastic screw clockwise. Seal the E55C PLAN+ modem with utility seals. 4.4 Removing/exchanging the E55C PLAN+ modem Disconnect the meter from mains before dismounting the E55C PLAN+ modem In order to avoid hazardous electric shocks, ensure there is no voltage applied to the meter when removing the E55C PLAN+ modem. The E55C PLAN+ modem is dismounted from the meter in reverse order of the installation (see sections 4.1 and 4.2). Landis+Gyr D en a E55C PLAN+ Modem User Manual

13 Operation 13/22 5 Operation This section describes the significance of the LEDs, the function of the push button and the operating modes of the E55C PLAN+ modem. The modem can be in two modes: normal operating mode or configuration mode. The modem enters normal operating mode at power up. Power on Normal operation PLC communication initialisation Configuration mode T Currently saved value Next value T = short push button press (< 3 s) = long push button press (> 3 s) = timeout after 1 minute without push button press (return without modification of value) Fig. 5: Operating mode diagram 1 Fig. 6: Push button on the E55C PLAN+ modem 1 Push button The push button of the E55C PLAN+ modem is accessible after removing the terminal cover (utility seal must be broken). It can be used to initialise the E55C PLAN+ modem, to enter and exit the configuration mode. The configuration mode allows the setting of the PLC transmission rate and the repeater state. D en a E55C PLAN+ Modem User Manual Landis+Gyr

14 14/22 Operation PLC communication initialisation Configuration mode From normal operation mode the PLC communication initialisation can be started with a short press of the push button (< 3 s). This sets the E55C PLAN+ modem in the unregistered and unlocked mode on the PLC communication (LED "PLC Registered" = off) and afterwards the E55C PLAN+ modem restarts like after a power off. From normal operation mode the configuration mode can be entered with a long press of the push button (> 3 s). The LED "PLC Tx/Rx" is fast blinking green with 10 Hz as long as the configuration mode is active. The currently saved value of "PLC transmission rate" and "Repeater state" are indicated using two LEDs Fig. 7: LEDs on the E55C PLAN+ modem 1 LED "PLC Tx/Rx" 2 LED "RS485 Tx/Rx" 3 LED "PLC Registered" 5.1 LED "PLC Tx/Rx" in normal operating mode The LED "PLC Tx/Rx" (position see Fig. 7) is bicolour (red and green) and has the following meaning during normal operating mode: Status Off Steady green Blinking green Blinking red Description No communication activities Power up sequence is being executed, device is not ready Data is being received by the E55C PLAN+ modem Data is being transmitted by the E55C PLAN+ modem Landis+Gyr D en a E55C PLAN+ Modem User Manual

15 Operation 15/ LED "RS485 Tx/Rx" in normal operating mode The LED "RS485 Tx/Rx" (position see Fig. 7) is bicolour (red and green) and has the following meaning during normal operating mode: Status Off Steady green Blinking green Blinking red Description No meter is connected on the RS485 interface Meter is connected on the RS485 interface Data is being received by the meter Data is being transmitted by the meter 5.3 LED "PLC Registered" in normal operating mode The LED "PLC Registered" (position see Fig. 7) is green and has the following meaning during normal operating mode: Status Off On Blinking Description PLC state = unlocked and unregistered PLC state = locked and registered PLC state = locked and unregistered 5.4 Configuration mode The configuration mode allows for six possible operating modes. These modes are available to the user by cycling through possible modes and then pressing the push button to save the setting. State LED "RS485 Tx/Rx" LED "PLC Registered" Mode 1 Steady red Off Always repeater mode at 1200 bits per second 2 Steady green Off Dynamic repeater mode at 1200 bits per second 3 Off Steady green Never repeater mode at 2400 bits per second 4 Steady red Steady green Always repeater mode at 2400 bits per second 5 Steady green Steady green Dynamic repeater mode at 2400 bits per second 6 Off Off Never repeater mode at 1200 bits per second Typically the modem is used in dynamic repeater mode. This mode is dynamic in the sense that periodically the modem may receive a repeater call from the concentrator that may provide a temporary instruction to repeat or not to repeat. This is intended to improve performance to combat clustering effects. The bit rate is determined by the system and must be known before units can be deployed. D en a E55C PLAN+ Modem User Manual Landis+Gyr

16 16/22 Maintenance 6 Maintenance 6.1 Service 6.2 Troubleshooting The E55C PLAN+ modem has no serviceable parts. Device service is available from the local Landis+Gyr representative. The following points should be checked first if there are problems with the E55C PLAN+ modem: 1. Is the mains voltage present (check display of meter)? 2. Has the maximum ambient temperature not been exceeded? 3. Are any changes or damage visible on the E55C PLAN+ modem? If none of these points contributes to the solution of the problem, check whether one of the measures described below helps solving the problem. If you do not succeed, replace the E55C PLAN+ modem. For details see section 6.3 "Repairing the E55C PLAN+ modem". Situation LED "PLC Tx/Rx" is steady green LED "PLC Tx/Rx" is fast blinking green (10 Hz) LED "PLC Registered" is off or blinking No remote communication possible (LED "PLC Tx/Rx" is continuously off) LED "RS485 Tx/Rx" is continuously off Description/Measure Power up sequence is being executed, device is not ready. Wait until power up sequence is finished. If the LED remains steady green all the time, replace the E55C PLAN+ modem. The E55C PLAN+ modem is in configuration mode. Long press the push button on the E55C PLAN+ modem (> 3 seconds) to save the configuration data and exit the configuration mode or wait 1 minute until the configuration mode is left without saving the modified configuration data. PLC state unregistered. Check whether PLC concentrators have been installed on the network. Check whether the LED "PLC Registered" is on (locked and registered). Check whether the configuration of "PLC transmission rate" and "Repeater state" is ok. Check the E55C PLAN+ modem connections. Check whether PLC concentrators have been installed on the network. No meter is connected on the RS485 interface. Make sure the E55C PLAN+ modem is not in configuration mode (LED "PLC Tx/Rx" is not fast blinking green). Check connection of the RS485 interface to the meter. Landis+Gyr D en a E55C PLAN+ Modem User Manual

17 Maintenance 17/ Repairing the E55C PLAN+ modem E55C PLAN+ modems must only be repaired by an authorised service and repair centre (or by the manufacturer). If the E55C PLAN+ modem needs to be repaired, perform the following steps: 1. Remove the defective E55C PLAN+ modem and install a replacement device. 2. Describe the error found as exactly as possible and state the name and telephone number of the person responsible in case of inquiries. 3. Pack the E55C PLAN+ modem to ensure it can suffer no further damage during transport. Use the original packing if available. Do not enclose any loose components. 4. Send the E55C PLAN+ modem to an authorised service and repair centre. D en a E55C PLAN+ Modem User Manual Landis+Gyr

18 18/22 Decommissioning and disposal 7 Decommissioning and disposal Electronic waste treatment This product must not be disposed of in regular waste. Use a professional electronic waste treatment process. The components used to manufacture the device can, in the main, be broken down into constituent parts and sent to an appropriate recycling or disposal facility. When the product is removed from use, the whole product must be sent to a professional electronic waste treatment process. The waste treatment and disposal plants must be approved by local regulatory authorities. The end processing of the product and recycling of its components must always be carried out in accordance with the rules and regulations of the country where the end processing and recycling are done. On request, Landis+Gyr will provide more information about the environmental impact of the product. Disposal and environmental protection regulations The following are general guidelines and should NOT take priority over local disposal and environmental policies which should be adhered to without compromise. Components Printed circuit boards Metal components Plastic components Disposal Delivered to recycling plants Sorted and delivered to metal recycling plants Sorted and delivered to re-granulation if at all possible Landis+Gyr D en a E55C PLAN+ Modem User Manual

19 Terms and abbreviations 19/22 8 Terms and abbreviations The following terms and abbreviations are used in this document. Term AMM DC GND LED PLAN PLC RTC RX TX UN UP Description Advanced Metering Management. AMM systems provide automated bidirectional communication between the energy meter and the utility. The communication is not limited to meter data but can include information about consumption, tariffs, alerts and complementary services. Data Concentrator Ground Light Emitting Diode Power Line Automation Network Power Line Carrier Real time calendar clock Receiver Transmitter Negative voltage (data b of RS485 interface) Positive voltage (data a of RS485 interface) D en a E55C PLAN+ Modem User Manual Landis+Gyr

20 20/22 Index 9 Index Abbreviations Characteristics... 7 Commissioning Configuration mode... 14, 15 Connecting Connections... 9 Construction... 8 Decommissioning De-installation Device description... 7 Disposal Disposal regulations Electronic waste treatment Environmental protection regulations Exchanging Faceplate... 8 Fitting Functional check Functions... 7 Installation Maintenance Mechanical description... 8 Operating mode diagram Operation Pin numbering of RJ12 socket... 9 PLAN+ modem... 7 PLC communication initialisation PLC/Mains connection... 9 Preparing for installation Protocol gateway... 7 Purpose of this manual... 3 Push button Reference documents... 3 Removing Repairing RJ12 socket pin numbering... 9 RS485 interface... 7, 9 Safety... 5 Information... 5 Regulations... 6 Responsibilities... 5 Scope of application... 7 Service Target group of this manual... 3 Terms Troubleshooting Typographical conventions... 3 Landis+Gyr D en a E55C PLAN+ Modem User Manual

21 Index 21/22 D en a E55C PLAN+ Modem User Manual Landis+Gyr

22 Contact: Landis+Gyr AG Theilerstrasse 1 CH-6301 Zug Switzerland Phone:

E65C CU-E20, E22. User Manual. Communication Industrial and Commercial

E65C CU-E20, E22. User Manual. Communication Industrial and Commercial Communication Industrial and Commercial CU-E20, E22 E65C User Manual E65C CU-E20, E22 communication units provide Ethernet communication between E650 or E850 meters and a central system. Date: 06.11.2009

More information

NXT4 Three phase meter for commercial, industrial and advanced residential applications

NXT4 Three phase meter for commercial, industrial and advanced residential applications EMH metering GmbH & Co. KG Neu-Galliner Weg 1 19258 Gallin GERMANY Tel. +49 38851 326-0 Fax +49 38851 326-1129 E-Mail info@emh-metering.com Web www.emh-metering.com Tel. +49 38851 326-1930 (Technical Support)

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions IO-Link master CabinetLine AL19xx Operating instructions IO-Link master CabinetLine AL19xx 80273036/00 02/2018 1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 2 Safety instructions Read

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Blitzer Strobe. User Manual. Order code: EQLED366

Blitzer Strobe. User Manual. Order code: EQLED366 Blitzer Strobe User Manual Order code: EQLED366 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

UV Power Flood. User Manual. Order code: EQLED029

UV Power Flood. User Manual. Order code: EQLED029 UV Power Flood User Manual Order code: EQLED029 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Operating Manual FPGA-based High-Speed Micro-PLC

Operating Manual FPGA-based High-Speed Micro-PLC ZX20T Operating Manual FPGA-based High-Speed Micro-PLC Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Deutschland info@zander-aachen.de www.zander-aachen.de Part No.: E61-335-10 Edition: H03 This document

More information

Gobo Projector XP 80W

Gobo Projector XP 80W Gobo Projector XP 80W User Manual Order code: EQLED084 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions Mounting and operating instructions Table of contents SFETY ND PRECUTIONS 3 PRODUCT DESCRIPTION 4 RTICLE CODES 4 INTENDED RE OF USE 4 TECHNICL DT 4 STNDRDS 4 WIRING ND CONNECTIONS 5 MOUNTING INSTRUCTIONS

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230 USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious

More information

User Manual Revision English

User Manual Revision English Document code: MN67152_ENG Revision 1.002 Page 1 of 17 User Manual Revision 1.002 English HD67152-A1 DeviceNet Master / Modbus TCP Slave - Converter (Order Code: HD67152-A1 HD67152-B2) for Website information:

More information

Island bus expansion module

Island bus expansion module s 8 184 8184P01 TX-I/O Island bus expansion TXA1.IBE Expand island bus to a distance of up to 2 x 200 meters Compact design per DIN 43 880, requires little space Easy installation and setup Mounted on

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

Installation Manual BAK02

Installation Manual BAK02 Installation Manual BAK02 XXXXXXXX/10-02-2014 Attention. Before installing the equipment, carefully read the SAFETY WARNINGS contained in the package as they provide important instructions regarding the

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

Crossfire. User Manual. Order code: EQLED061

Crossfire. User Manual. Order code: EQLED061 Crossfire User Manual Order code: EQLED061 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A)

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A) Modem/Router INSTRUCTION MANUAL (M179B01-03-17A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could result in personal injury

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Language of the manual

Language of the manual USER S MANUAL INSTALLATION AND Language of the manual Product English Single-phase switching power supply: 24V @ 1.5A Description Contents: 1.0 Disclaimer 2.0 Description and General features Page 2 2

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. Technical Data

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. Technical Data Electricity Meters IEC/MID Residential ZxF100Ax/Cx E350 series 2 Technical Data Building on its tradition of open communication meters, Landis+Gyr is now bringing out the E350, the latest generation of

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Installation manual for for Schleifenbauer DPM3

Installation manual for for Schleifenbauer DPM3 Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014 Mounting Instruction Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family RM Sb MACH104-20TX-F USB V.24 1 3 5 7 9 11 13 15 17 19 21 23 Aufkleber MAC-Adresse P 2 4 6 8 10 12 14 16 18 20 22 24

More information

User Manual Revision English

User Manual Revision English Document code: MN67251_ENG Revision 1.001 Page 1 of 18 User Manual Revision 1.001 English NMEA 2000 / DeviceNet - Converter (Order Code: HD67251-A1 - HD67251-A3 - HD67251-A4) for Website information: www.adfweb.com?product=hd67251-a1

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Electronic Rotational Speed Monitoring Device Type EDO Device Identification No.: 93.045 508.001 /.005 /.007 /.012 OPERATING INSTRUCTIONS 2 CE-Sign an Conformity The device meets the requirements of the

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3. Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices

More information

RGB Power Batten. User Manual. Order code: EQLED032

RGB Power Batten. User Manual. Order code: EQLED032 RGB Power Batten User Manual Order code: EQLED032 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date: Documentation KM10xx Terminal Modules with Digital Inputs Version: Date: 3.1.0 2017-01-23 Product overview KM10xx Product overview KM10xx KM1002, KM1012 [} 11] - 16 inputs, input filter 3 or 0.2 ms KM1004,

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002 S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................

More information

User Manual Revision English

User Manual Revision English Document code: MN67562_ENG Revision 1.005 Page 1 of 14 User Manual Revision 1.005 English PROFIBUS Slave / Modbus Slave - Converter (Order Code: HD67562) for Website information: www.adfweb.com?product=hd67562

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A AC24..230V/5A (6ES7132-4HB50-0AB0) SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A

More information

User Manual Revision English

User Manual Revision English Document code: MN67140_ENG Revision 1.011 Page 1 of 18 User Manual Revision 1.011 English DeviceNet Slave / Modbus TCP Slave - Converter (Order Code: HD67140-A1 HD67140-B2) for Website information: www.adfweb.com?product=hd67140

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008 SENTRON PAC3200 Operating Instructions Read and understand these instructions and the relevant manual before installing, operating, or maintaining the equipment. CAUTION DANGER Hazardous voltage. Will

More information

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About

More information

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001 PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

User Manual. Printer P-52RUE

User Manual. Printer P-52RUE User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4

More information

Rotary version, three-position control

Rotary version, three-position control 4 622 Residential Air damper actuators GXD..31.1 Rotary version, three-position control Electric motor-driven actuators for three-position control 1.5 Nm nominal torque AC 24 V or AC 230 V rated voltage

More information

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC

Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series. Document Number: IN R01 Copyright SCALAMAX, LLC SCALAMAX Protocol LX-10 Series Gateways Teslights Hybrid Lighting SCALAMAX Protocol LX10 Gateway Series Document Number: IN-0000033-R01 Copyright SCALAMAX, LLC 2010-2020 Compliant Index Warning... 2 Disclaimer...

More information

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date: Documentation KM2002, KM2004, KM2008 Terminal modules with digital outputs, 24 V, 0.5 A Version: Date: 3.2.0 2017-01-23 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation...

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006 s SIWAREX JB Aluminum Housing Instruction Manual Edition 03/2006 Table of Contents Table of Contents... 2 Warning and Safety Terms... 3 General... 4 1 Technical Description... 5 1.1 Area of Application...

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

SolConeX Wall-Mounted Socket, 16 A

SolConeX Wall-Mounted Socket, 16 A SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

Communication gateway ihub-l1

Communication gateway ihub-l1 Communication gateway ihub-l1 October 2018 Version 1.00 1 Communication gateway ihub-l1 Communication gateway ihub-l1 User and Installation manual ii Communication gateway ihub-l1 Security Advices and

More information

HEC. General Operating, Maintenance and Installation Manual

HEC. General Operating, Maintenance and Installation Manual HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version

More information

CEM-C6 INSTRUCTION MANUAL (M187B B)

CEM-C6 INSTRUCTION MANUAL (M187B B) Multifunctional Energy Meter INSTRUCTION MANUAL (M187B01-03-18B) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could result

More information

PXR11 PXR12. System controllers DESIGO PX

PXR11 PXR12. System controllers DESIGO PX 9 235 DESIGO PX System controllers PXR11 PXR12 For integration of the room controllers in the DESIGO RXC range into the DESIGO building automation and control system (operates as an interface) For the

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions Introduction 1 Installing/Mounting 2 SITRANS F Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel Hardware Installation Instructions 1/2010 A5E02518333A Revision 04 Legal information Warning notice

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date: Documentation KM2604 and KM2614 Four channel relay module Version: Date: 2.1.0 2017-12-01 Tabel of contents Tabel of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5 ILUMEN PID SOLUTION ILUMEN PIDBOX MINI INSTALLATION MANUAL INDOOR OUTDOOR Ilumen PIDbox mini Version 1.5 1 TABLE OF CONTENT 1 Information on this manual... 3 1.1 Validity... 3 1.2 Target group... 3 1.3

More information

584 5WG AB_1 DELTA

584 5WG AB_1 DELTA Product DELTA profil DELTA style DELTA ambiente Display and control unit 5WG1 585-2AB01 pearl grey 5WG1 585-2AB11 titanium white 5WG1 585-2AB21 anthracite 5WG1 585-2AB71 silver 5WG1 585-2AB11 titanium

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information