MEDICAL INSTRUMENTS. AVL 9120, 9130, 9140, 9180, 9181 Electrolyte Analyzers. Service Manual

Size: px
Start display at page:

Download "MEDICAL INSTRUMENTS. AVL 9120, 9130, 9140, 9180, 9181 Electrolyte Analyzers. Service Manual"

Transcription

1 MEDICAL INSTRUMENTS AVL 90, 90, 90, 980, 98 Electrolyte Analyzers Service Manual

2 Tenth Edition vember 99 Copyright, 99, AVL Scientific Corporation. All rights reserved. Unless otherwise noted, no part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form without the written permission of AVL Scientific Corporation. For information contact: AVL Scientific Corporation AVL MEDICAL INSTRUMENTS AG AVL LIST GmbH 50 Mansell Court Stettemerstrasse 8 Kleiststrasse 8 P.O. Box CH-80 Schaffhausen A-800 Graz Roswell, Georgia USA 00 Switzerland Austria Printed in USA US085 REV K ii

3 Important Information! This Operator s Manual contains important warnings and safety information to be observed by the user. This instrument is only intended for one area of application which is described in the instructions. The most important prerequisites for application, operation and safety, are explained to ensure smooth operation. warranty or liability claims will be covered if the instrument is applied in areas other than those described or if the necessary prerequisites and safety measures are not observed. The instrument is only to be operated by qualified personnel capable of observing these prerequisites. Only accessories and supplies either delivered by or approved by AVL are to be used with the instrument. Due to the operating principle of the instrument, analytical accuracy not only depends on correct operation and function, but also upon a variety of external influences beyond the manufacturers control. Therefore, the test results from this instrument must be carefully examined by an expert, before further measures are taken based on the analytical results. Instrument adjustment and maintenance with removed covers and connected power mains are only to be performed by a qualified technician who is aware of the dangers involved. Instrument repairs are only to be performed by the manufacturer or qualified service personnel. Symbol Explanation Attention symbol - Refer to the Operator's Manual or Service Manual for further instructions. This symbol is located on the inside of the instrument. Type B instrument symbol - An instrument of the B type falls under safety categories I, II, or III, or has an internal power supply providing the required insulation against discharge current and reliable ground connections. Important Information! iii

4 Operating Safety Information This instrument falls under Safety Category I. This instrument is a Class B instrument. This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference s, and () this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. te: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 5 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio TV technician for help Caution: The instrument is designed as a conventional device (closed, not waterproof type). Do not operate the instrument in an explosive environment or in the vicinity of explosive anesthetic mixtures containing oxygen or nitrous oxide. This instrument is suitable for continuous operation. The power plug is to be plugged into a ground socket only. When using an extension cord, make sure that it is of the proper size and is properly grounded. Any breakage of the ground lead inside or outside the instrument or a loose ground connection can cause a hazardous condition when operating the instrument. Intentional disconnection of the grounding is not permitted. When replacing the fuses, make sure that they are of the same type and rating as the original fuses. Never use repaired fuses or short-circuit the fuse holders. Operating Safety Information iv

5 Contents Introduction... General Description.... Reported Parameters.... Operating Parameters... Software System Software Flow Charts 90, 0, System Software Flow Charts System Software Flow Charts Service Functions... Description of Modules Mechanical Assemblies Fluidic Module Electronics Maintenance and Troubleshooting Maintenance Procedures Error Messages and Troubleshooting Adjustments Sample Sensor Adjustment Temperature Adjustment... Electronic Diagrams... System Block Diagram 90, 0, 0, System Block Diagram System Interconnect 90, 0, SBC PCB - Power Supply 90, 0, 0... SBC PCB - Valve Drivers 90, 0, SBC PCB - Pump Motor Driver/Door Detect 90, 0, SBC PCB - Input Amplifiers 90, 0, SBC PCB - Temperature Circuit 90, 0, SBC PCB - Analog Selector and A/D Converter 90, 0, v

6 SBC PCB - Microprocessor 90, 0, SBC PCB - Printer/Display Drivers 90, 0, Printer Daughter PCB 90, 0, 0, 80, Lamp PCB 90, 0, Display Daughter PCB 90, 0, System Interconnect 980/ SBC PCB - Power Supply 980/ SBC PCB - Valve Drivers 980/ SBC PCB - Pump Motor Driver/Door Detect 980/ SBC PCB - Input Amplifiers 980/ SBC PCB - Temperature Circuit 980/ SBC PCB - Analog Selector and A/D Converter 980/ SBC PCB - Microprocessor 980/ SBC PCB - Printer/Display Drivers 980/ SBC PCB - Fluid Pack Detector 980/ Lamp PCB 980/ Display Daughter PCB Parts List Main Assembly Front... 0 Main Assembly Rear... 0 Electrode Holder Assembly... 0 Needle Unit Assembly... 0 Rear Panel Assembly Front Door Assembly Interface Specifications Interface Information Example Data String Information Data Link Information vi

7 Introduction The Service Manual for the 90, 0, 0, 80, and 8 Electrolyte Analyzers contains the technical information needed to ensure easy fault identification. This manual is intended to be complementary to the Operator's Manual where detailed instructions for operation, maintenance and troubleshooting are provided. As for all clinical instrumentation, a thorough understanding of the principles of operation is prerequisite to attempting service of this product. Training along with experience will enhance the use of this manual. Service and repair of 90, 0, 0, 80, and 8 analyzers should be performed only by qualified repair technicians. Care should be taken when removing the covers as hazardous voltages are exposed. Use only accepted electronic test procedures and static protection when replacing and handling all electronic parts. This manual is divided into 9 chapters to facilitate location of technical information. Chapter provides specifications and operating parameter information. Chapter includes flow charts for all system functions and detailed operation of system test procedures. In Chapter, all mechanical, fluidic and electronic assemblies are described. Chapter 5 outlines routine maintenance and troubleshooting procedures. Chapter 6 includes electronic adjustments and Chapter provides the system block diagram and all circuit schematic diagrams and wiring interconnection information. In Chapter 8, part identification, location and description is provided by the illustrated parts list. Finally, in Chapter 9 interface specifications are provided for the RS output.

8 General Description Specifications. Reported Parameters Measuring Range Resolution Whole Blood Serum Plasma Sodium Na mmol/l 0. mmol/l Potassium K mmol/l 0.0 mmol/l (0.8-5 mmol/l dialysate) Chloride Cl mmol/l 0. mmol/l Calcium Ca mmol/l 0.0 mmol/l Lithium Li mmol/l 0.00 mmol/l Urine Sodium Na mmol/l.0 mmol/l Potassium K mmol/l 0. mmol/l (60-0 mmol/l w. addit. dilution) Chloride Cl mmol/l.0 mmol/l Calcium and Lithium are not measured in urine samples. Lithium is not measured in dialysate samples.. Operating Parameters Sample type Whole blood, serum, plasma, urine, dialysate (acetate or bicarbonate) Sample device Syringe, sample cup, collection tube, capillary Sample size 95 µl Analysis time 50 seconds Sample rate 5 per hour with printout 60 per hour without printout

9 Measurement Sodium (Na + ) sensor Potassium (K + ) sensor Chloride (Cl - ) sensor Calcium (Ca ++ ) sensor Lithium (Li + ) sensor Reference System Calibration Standby Mode Warm-up time Temperature Humidity Data management Diagnostic Programs Electronics Display Printer Autosampler (98 only) Ion-selective, flow-through, glass capillary electrode Ion-selective, flow-through, liquid membrane electrode Ion-selective, flow-through, liquid membrane electrode Ion-selective, flow-through, liquid membrane electrode Ion-selective, flow-through, liquid membrane electrode Open liquid junction, flow-through electrode Fully automatic point with each sample point every hours (980/98 every hrs.) suspends calibrations minute Room temperature, 5 - C, F maximum 85% relative humidity, non-condensing Quality Control memory storage, levels, 5 values; calculation of mean, standard deviation, and coefficient of variation (CV) user-controlled diagnostics, / operation via the display Microprocessor-controlled LCD dot-matrix, line, 6 characters per line Integral thermal printer, 6 character width Integral turntable - 8 positions, ml or 0.5 ml sample cups

10 Interface RSC Serial Port Data Link Data link to Compact / (980/98) Electrical requirements minal power consumption 00-0 V~, 50/60 Hz,. A max. Self-adjusting 0 W Dimensions height width depth weight."; 5mm."; 5m.0"; 95mm approx. lbs; 6kg Classifications Safety category I Device type B (according to ÖVE-MG/EN 6060-, IEC 60-) Mode of operation continuous operation Protection classification IP 0 Explosion protection the device is not designed for operation in explosive environments. Approvals CSA, CE, FCC Class B CLIA Complexity Category: Moderate Test System Code: 09 FDA 50(k) number: K96 Analyte Codes: Na + : 5805 K + : 90 Cl - : 08 ica ++ : 00 Li + : Data subject to change without notice. Technical information is supplied for general informational purposes only.

11 Software Operation. Software Operation - 90, 90, 90 Software operation of the 90, 90, 90 analyzers can be accessed by / selection on the analyzer front panel. The following flow chart diagrams are provided to identify operating sequences of the 90, 90, 90 Analyzers:. Overall Program Operating Flow. Main Menu. Measurement Sequence. Print Functions Menu 5. QC/Standard/Urine Sample Menu 6. Daily Maintenance Menu. Operator Functions Menu 8. Program Instrument Menu 9. Service Functions Menu 0. Calibration Sequence. Software Operation Overall Program Operating Flow. Main Menu. Measurement Sequence. Print Functions Menu 5. QC/Std/Dialysate/Urine Sample Menu 6. Daily Maintenance Menu. Operator Functions Menu 8. Program Instrument Menu 9. Service Functions Menu 0. Calibration Sequence. Power-up Sequence 5

12 . Software Operation Overall Program Operating Flow. Main Menu. Measurement Sequence. Print Functions Menu 5. QC/Std/Dialysate/Urine Sample Menu 6. Daily Maintenance Menu. Operator Functions Menu 8. Program Instrument Menu 9. Service Functions Menu 0. Calibration Sequence. Power-up Sequence The Service Functions Menu is also provided with a more detailed description of each test parameter for use in testing instrument subassemblies. 6

13 . Software Operation - 90, 0, 0 Overall Program Operating Flow - 90, 0, 0 R E ADY :5 PRINT FUNCTIONS? Yes P rint las t Sample Report? Print Cal. R eport? Print QC Values and S tatis tics? Yes R emain in P rint Functions? QC/S T ANDAR D/ URINE SAMPLE? DAILY MAINT E NANCE? OP E R AT OR FUNCTIONS? PROGRAM INS T R U ME NT? SERVICE FUNCTIONS? CALIBR AT ION? Yes Yes Yes Yes Yes Yes QC L evel Sample? Daily Cleaning? Check/Change SnapPak? Enter Code: AAA Test E lectrodes? CALIB R AT E.. QC L evel Sample? Daily Conditioning? Go to S tandby Mode? Program QC Level Ranges? Test Sample Sensor? QC L evel Sample? Yes R emain in Daily Maintenance? Set Time/Date? Program QC Level Ranges? Test S ample Door? Standard Sample? CALIB R AT E Reset Sample Number? Program QC Level Ranges? Test Pump? Urine Sample? Take Out of Operation? Program rmal R anges? Test Valves? Remain in QC/ Yes Std/Urine Sample? Yes R emain in Operator F unc.? Program Corr. F actors? Test Interface? Jump Pins & Program P rinter S etup? Test Amplifier? Yes R emain in Program Func.? Enter S ervice Code? Yes R emain in Service Func.?.

14 Main Menu - 90, 0, 0 MAIN MENU READY :5 LEGEND Display prompt PRINT FUNCTIONS? Action performed by analyzer QC/STANDARD/ URINE SAMPLE? -second display prompt DAILY MAINTENANCE? Decision-making by analyzer OPERATOR FUNCTIONS? PROGRAM INSTRUMENT? SERVICE FUNCTIONS? CALIBRATION? 8

15 Measurement Sequence - 90, 0, 0 READY :5 OPEN FLAP PRINT FUNCTIONS? Open Sample Door Introduce Sample DOOR OPENED WITHIN s? Please Introduce Sample CHECK SS VOLTAGE < air voltage > air voltage Remove Sample and Wipe Probe Remove Sample and Wipe Probe s Please Close Sample Door FLAP CLOSED Serum Sample in Process 9 s Please Close Sample Door FLAP CLOSED Blood Sample in Process 9 Na K Cl 5 5. / min. Na K Cl 5 5. / min. 9

16 Print Functions Menu - 90, 0, 0 PRINT FUNCTIONS? QC/STANDARD/ URINE SAMPLE? Print Last Sample Report? PRINTING... Print Cal. Report? PRINTING... READY :5 Print QC Values and Statistics? PRINTING... Remain in Print Functions? READY :5 0

17 5 QC/Standard/Urine Sample Menu - 90, 0, 0 QC/STANDARD/ URINE SAMPLE? DAILY MAINTENANCE? min. QC Level Sample? OPEN Introduce SAMPLE Open Sample Door Wipe Probe/Close Sample Introduce Sample Sample Door IN s VALUES REJECTED! s Store Values? CLOSED s QC Level in Process 9 Na K Cl s VALUES ACCEPTED! min READY :5 min. QC Level Sample? OPEN Introduce SAMPLE Open Sample Door Sample Introduce Sample IN s VALUES REJECTED! Wipe Probe/Close Sample Door s Store Values? CLOSED s QC Level in Process 9 Na K Cl s VALUES ACCEPTED! min READY :5 min. QC Level Sample? Open Sample Door OPEN Introduce SAMPLE Sample Introduce Sample IN s VALUES REJECTED! Wipe Probe/Close Sample Door s Store Values? CLOSED s QC Level in Process 9 Na K Cl s VALUES ACCEPTED! min READY :5 min. min. Standard Sample? Urine Sample? 5s OPEN Introduce SAMPLE Open Sample Door Sample Introduce Sample IN 5s OPEN Introduce SAMPLE Open Sample Door Sample Introduce Sample IN Wipe Probe/Close Sample Door Wipe Probe/Close Sample Door CLOSED CLOSED Standard Sample in Process 9 Urine Sample in Process 9 Na K Cl min. / Na K Cl min. / Remain in QC/ Std/Urine Sample? / min. READY :5

18 6 Daily Maintenance Menu - 90, 0, 0 DAILY MAINTENANCE? OPERATOR FUNCTIONS? Daily Cleaning? OPEN Open Sample Door Introduce Sample OPEN Wipe Probe/CloseCLOSE Cleaning Solution Sample Door detected? CLEAN Cleaning Solution not detected! Daily Conditioning? OPEN Open Sample Door Introduce Sample OPEN Wipe Probe/Close CLOSE Condition. Solution Sample Door detected? CONDITION Condition. Solution not detected! Remain in Daily Maintenance? /min. CLEANING AND/OR COND. PERFORMED? 0 SECOND STABILIZATION CALIBRATE READY :5 Calibration due?

19 Operator Functions Menu - 90, 0, 0 OPERATOR FUNCTIONS? Check/Change SnapPak? PROGRAM INSTRUMENT? % remaining Change SnapPak? New SnapPak installed? Fluid Counter reset to 00% Go to Standby Mode ***STANDBY!*** -> READY Maint. due? / New Pack Prime... Leave Standby Mode? CALIBRATE Set Time/Date? IS PRESS CALIBRATION WITHIN s DUE? Daily Cleaning? Date: 0-FEB-9 Time: :00 ok? Date: 0-FEB-9 Time: :00 ok CLEAN READY :5 Daily Conditioning? CONDITION 0 SECOND STABILIZATION CALIBRATE READY :5 Remain in Daily Maintenance? min/ IS CALIBRATION DUE? Reset Sample Number? Take out of Operation? Remain in Operator Func? Are you sure? Shutdown Plug / Water installed? ShutdownComplete Turn Power Off / SET SAMPLE NUMBER TO 0 Transp Housing Remove Water Ref installed? and Press Do You Wish to DELETE all Data? Pump Windings Relieved? All Electrodes & Plug Removed? Relief Clamps Inserted?

20 8 Program Instrument Menu - 90, 0, 0 PROGRAM INSTRUMENT? SERVICE FUNCTIONS? Enter Code: AAA CORRECT Program QC Level Ranges? IN- CORRECT CODE ERROR! RETRY? Current Lot: 0000 Print old Values New Lot! Change Lot? and Statistics? Delete old Data? Enter last Dig of Lot#: 0000 Cl low = 050 Cl high = 00 K low =.5 K high = 5.0 Na low = 00 Na high = 05 Lot Number ok? Program QC Level Ranges? Program QC Level Ranges? "see Level " "see Level " Program rmal Ranges? Na low = 5.0 K low =.50 Cl low = 95.0 Na high = 50.0 K high = 5.50 Cl high = 08.0 Program Corr Factors Reset Corr Factor (default)? Input/Verify Corr Factors? Remain in Corr Factors? Cl (b) = Cl (m) =.000 K (b) = K (m) =.000 Na (b) = Na (m) =.000 Program Printer Setup? Patient Report off? Print two Patient Reports? / Automatic Cal Report? / Remain in Program Func? READY :5

21 9 Service Functions Menu - 90, 0, 0 SERVICE FUNCTIONS? CALIBRATION? Test Electrodes? Test Standard A? Std. A: Na =0000 K =0000 Cl =0000 Test Standard B? Std. B: Na =0000 K =0000 Cl =0000 Test External Sample? Open Door and Introduce Sample OPEN Introduce Sample Remain in Test Electrodes? Ext.: Na =0000 K =0000 Cl =0000 CLOSED Wipe Probe and Close Sample Door Test Sample Sensor? DRY: 80-0: 0 =Pump/=Exit External: 0 Pump: =OFF wash... Test Sample Door? Sample Door: C C:Closed O:Open Test Pump? Test Pump! Very slow speed s Test Pump! s Test Pump! s Slow speed Medium speed Test Pump! Fast speed s Test Valves? Test Valve A: /=ON/OFF Test Valve B: Test Valve V: /=ON/OFF /=ON/OFF Test Valve R: /=ON/OFF Test Interface? Jump Pins & -- Test Interface -- Interface ok! Remain in Test Interface? Test Amplifier? Na=-00 K=-00 Cl = -09 Ground = -500mV = -96 Enter Service Code? Enter Code: Is Code AAA ok? valid? Code Accepted! Enter Other Service Code? Code Error! Remain in Service Func? Calibration? Calibrate... READY :5 5

22 0 Calibration Sequence - 90, 0, 0 CALIBRATION? A Calibration in Process Asp. Std. A into Meas. Chamber Clear Sample Path Standard A detected? **STANDARD A** T DETECTED Calibrate Sample Sensor Obtain Electrode Voltages Std. A Sample Sensor Voltage ok? ***CHECK*** SAMPLE SENSOR Std. A Values obtained? Prime Standard B Are Values reproducible? 6 Aspir. of Std.A performed? Standard B detected? **STANDARD B** T DETECTED Aspir. Std. B into Meas. Chamber ***CHECK*** ELECTRODES Prime Standard A Standard B detected? **STANDARD B** T DETECTED Standard A detected? **STANDARD A** T DETECTED Obtain Electrode Voltages Std. B Pressurize Ref. Asp. Std. A into Meas. Chamber Perform Wash Cycle Reference Housing ok? ***CHECK*** REF HOUSING Aspir. Std. A into Meas. Chamber A Standard A detected? **STANDARD A** T DETECTED Calculation of Std.A-Std.B (slope) Slope of all Electrodes in Range? At least slope in Range? ***CHECK*** ELECTRODES READY :5 READY :5 XX T CAL'D 6

23 . Software Operation Overall Program Operating Flow Na K Cl READY PRINT FUNCTIONS? Yes Print last Sample Report? Print Cal. Report? Print QC Values and Statistics? Yes Remain in Print Functions? Yes QC/STD/DIALYSATE /URINE SAMPLE? DAILY MAINTENANCE? OPERATOR FUNCTIONS? PROGRAM INSTRUMENT? SERVICE FUNCTIONS? CALIBRATION? Yes Yes Yes Yes Yes Yes QC Level Sample? Perform Daily Cleaning? Check/Change SnapPak? Enter Code: AAA Test Electrodes? CALIBRATE... QC Level Sample? Perform Daily Conditioning? Go to Standby Mode? Program QC Level Ranges? Test Sample Sensor? QC Level Sample? Yes Remain in Daily Maintenance? Set Time/Date? Program QC Level Ranges? Test SnapPak Sensor? Standard Sample? CALIBRATE... Select Parameter Configuration? Program QC Level Ranges? Test Language Switch? Bicarbonate Sample? Reset Sample Number? Program rmal Ranges? Test Sample Door? Acetate Sample? Take Out of Operation? Program Corr. Factors? Test Pump? Urine Sample? Remain in QC/ Std/Urine Sample? Yes Remain in Operator Func.? Program Bicarb. Corr Factors? Program Acetate Corr Factors? Test Valves? Test Interface? Jump Pins & Program Urine Corr Factors? Test Amplifier? Program Printer Setup? Enter Service Code? Program Interface? Yes Remain in Service Func.? Yes Remain in Program Func.?

24 Main Menu MAIN MENU NA K CL READY LEGEND Display prompt PRINT FUNCTIONS? Action performed by analyzer QC/STD/DIALYSATE /URINE SAMPLE? -second display prompt DAILY MAINTENANCE? Decision-making by analyzer OPERATOR FUNCTIONS? PROGRAM INSTRUMENT? SERVICE FUNCTIONS? CALIBRATION? 8

25 Measurement Sequence NA K CL READY OPEN FLAP PRINT FUNCTIONS? Open Sample Door Introduce Sample DOOR OPENED WITHIN s? Please Introduce Sample CHECK SS VOLTAGE < air voltage > air voltage Remove Sample and Wipe Probe Remove Sample and Wipe Probe s Please Close Sample Door Serum Sample in Process 9 FLAP CLOSED s Please Close Sample Door Blood Sample in Process 9 FLAP CLOSED / min. Na K Cl 5 5. Na K Cl 5 5. / min. 9

26 Print Functions Menu PRINT FUNCTIONS? QC/STD/DIALYSATE /URINE SAMPLE? Print Last Sample Report? PRINTING... Print Cal. Report? PRINTING... NA K CL READY Print QC Values and Statistics? PRINTING... Remain in Print Functions? NA K CL READY 0

27 5 QC/Standard/Dialysate/Urine Sample Menu QC/STD/DIALYSATE /URINE SAMPLE? DAILY MAINTENANCE? min. QC Level Sample? OPEN SAMPLE Open Sample Door Introduce Sample Introduce Sample IN OPEN s VALUES REJECTED! Wipe Probe/Close Sample Door s Store Values? CLOSED s QC Level in Process 9 Na K Ca s VALUES ACCEPTED! min NA K CA READY min. QC Level Sample? OPEN SAMPLE Open Sample Door Introduce Sample Introduce Sample IN OPEN s VALUES REJECTED! Wipe Probe/Close Sample Door s Store Values? CLOSED s QC Level in Process 9 Na K Ca s VALUES ACCEPTED! min NA K CA READY min. QC Level Sample? Open Sample Door OPEN Introduce Sample SAMPLE Introduce Sample IN OPEN s VALUES REJECTED! Wipe Probe/Close Sample Door s Store Values? CLOSED s QC Level in Process 9 Na K Ca s VALUES ACCEPTED! min NA K CA READY min. min. min. min. Standard Sample? Bicarbonate Sample? Acetate Sample? Urine Sample? 5s Open Sample Door OPEN Introduce Sample SAMPLE Introduce Sample OPEN IN 5s Open Sample Door OPEN Introduce Sample SAMPLE OPEN Introduce Sample IN 5s Open Sample Door OPEN Introduce Sample SAMPLE Introduce Sample OPEN IN 5s Open Sample Door OPEN Introduce Sample SAMPLE Introduce Sample OPEN IN Wipe Probe/Close Sample Door Wipe Probe/Close Sample Door Wipe Probe/Close Sample Door Wipe Probe/Close Sample Door CLOSED CLOSED CLOSED CLOSED Standard Sample in Process 9 Bicarb. Sample in Process 9 Acetate Sample in Process 9 Urine Sample in Process 9 Na K Ca min. / Na K Ca min. / Na K Ca min. / Na K Cl min. / Remain in QC/ Std/Urine Sample? / min. NA K CA READY

28 6 Daily Maintenance Menu DAILY MAINTENANCE? OPERATOR FUNCTIONS? Perform Daily Cleaning? OPEN Open Sample Door Introduce Sample OPEN Wipe Probe/Close CLOSE Cleaning Solution Sample Door detected? CLEAN Cleaning Solution not detected! Perform Daily Conditioning? OPEN Open Sample Door Introduce Sample OPEN Wipe Probe/Close CLOSE Condition. Solution Sample Door detected? CONDITION Condition. Solution not detected! Remain in Daily Maintenance? /min. CLEANING AND/OR COND. PERFORMED? 0 SECOND STABILIZATION CALIBRATE NA K CA READY Calibration due?

29 Operator Functions Menu *****STATUS***** ** SnapPak** OPERATOR FUNCTIONS? Check/Change SnapPak? PROGRAM INSTRUMENT? % remaining Change SnapPak? Pack detected? GLOBAL* New SnapPak installed? *Background check in all menus except "Take out of Operation?" Fluid Counter reset to 00% Go to Standby Mode ***STANDBY!*** -> READY Maint. due? / New Pack Prime... Set Time/Date? Select Parameter Configuration? Reset Sample Number? Take out of Operation? Remain in Operator Func? Leave Standby Mode? PRESS IS CALIBRATION WITHIN s DUE? Date: 0-FEB-9 Time: :00 ok? Date: 0-FEB-9 Time: :00 ok Are you sure? Shutdown Plug and Water installed? Shutdown Complete Turn Power Off / NA K Daily Cleaning? CLEAN READY SET SAMPLE NUMBER TO 0 Transp Housing Ref installed? Do You Wish to DELETE all Data? Daily Conditioning? CONDITION 0 SECOND STABILIZATION CALIBRATE Sel. Parameter: Sel. Parameter: Sel. Parameter: [Na] [K] [ ] ok? [Na] [K] [Cl] ok? [Na] [K] [Ca] ok? Sel. Parameter: ([Na]) [ ] [Li] ok? Remove Water and Press Pump Windings Relieved? CALIBRATE Na K READY Remain in Daily Maintenance? min/ IS CALIBRATION DUE? New Parameter added? Electrodes in place? Sel. Parameter: [Na] [K] [Li] ok? Sel. Parameter: [Na] [ ] [Li] ok? All Electrodes & Plug Removed? 5 Relief Clamps Inserted?

30 8 Program Instrument Menu PROGRAM INSTRUMENT? SERVICE FUNCTIONS? Enter Code: AAA IN- CORRECT CODE ERROR! RETRY? CORRECT Program QC Level Ranges? Current Lot: 0000 Print old Values New Lot! Change Lot? and Statistics? Delete old Data? Enter last Dig of Lot#: 0000 Additional Parameters? K low =.5 K high = 5.0 ok? Na low = 00 Na high = 05 ok? Enter last Dig of Lot#: 0000 ok? Cl low = 050 Cl high = 00 ok? Ca low = 0. Ca high = 5.0 ok? Li low = 0. Li high = 6.0 ok? Program QC Level Ranges? Program QC Level Ranges? "see Level " "see Level " Program rmal Ranges? Na low = 6 K low = 0.5 Na high = 5 ok? K high = 05. ok? Program Corr Factors Reset Corr Factor (default)? Input/Verify Corr Factors? Remain in Corr Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Bicarb. Corr Factors Reset Bicarb. Factor (default)? Input/Verify Bicarb. Factors? Remain in Bicarb Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Acetate Corr Factors Reset Acetate Factor (default)? Input/Verify Acetate Factors? Remain in Acetate Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Urine Corr Factors Reset Urine Factor (default)? Input/Verify Urine Factors? Remain in Urine Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Printer Setup? Patient Report off? Print two Patient Reports? / Automatic Cal Report? / Enter Comment Line? Enter Comment: _ Program Interface? Activate Data Link? / Remain in Program Func? NA K READY

31 9 Service Functions Menu SERVICE FUNCTIONS? CALIBRATION? Test Electrodes? Test Standard A? Std. A: Na = 0000 K = 0000 Ca = 0000 Test Standard B? Std. B: Na = 0000 K = 0000 Ca = 0000 Test Standard C? Std. C: Na = 0000 K = 0000 Ca = 0000 Test External Sample? Open Door and Introduce Sample OPEN Introduce Sample Remain in Test Electrodes? Ext.: Na = 0000 K = 0000 Ca = 0000 CLOSED Wipe Probe and Close Sample Door Test Sample Sensor? DRY: 80-0: 0 =Pump/=Exit External: 0 Pump: =OFF wash... Test SnapPak Sensor? SnapPak: I I=In O=Out / Test Language Switch? Language Switch English / Test Sample Door? Sample Door: C C:Closed O:Open Test Pump? Test Pump! Very slow speed s Test Pump! s Test Pump! s Slow speed Medium speed Test Pump! Fast speed s Test Valves? Test Valve A: /=ON/OFF Test Valve B: Test Valve C: /=ON/OFF /=ON/OFF Test Valve V: /=ON/OFF Test Interface? Jump Pins & -- Test Interface -- Interface ok! Remain in Test Interface? Test Valve R: /=ON/OFF Test Amplifier? Na = -00 K = -00 Cl = -09 Ground = -500mV = -96 Temp (mv) = -60 Temp ( C) = 6. Enter Service Code? Enter Code: Is Code AAA ok? valid? Code Accepted! Enter Other Service Code? Code Error! Retry? Remain in Service Func? Calibration? Calibrate... NA K CA READY 5

32 0 Calibration Sequence () (Example Na/K/Li Calibration) CALIBRATION? A Calibration in Process Asp. Std. A into Meas. Chamber Clear Sample Path Standard A detected? **STANDARD A** T DETECTED Calibrate Sample Sensor Obtain Electrode Voltages Std. A Sample Sensor Voltage ok? ***CHECK*** SAMPLE SENSOR Std. A Values obtained? Prime Standard B Are Values reproducible? 6 Aspir. of Std.A performed? Prime Standard C Aspir. Std. B into Meas. Chamber At least Channel reprod.? Prime Standard A Standard B detected? **STANDARD B** T DETECTED ***CHECK*** ELECTRODES All Standards not detected? *********CLOG******** CHECK FLUID PATH Obtain Electrode Voltages Std. B Two Standards not detected? **STANDARD X/Y** T DETECTED Calc. of Std.A- Std.B (slope) Standard A,B,C not detected? **STANDARD X** T DETECTED At least slope in Range? ***CHECK*** ELECTRODES Pressurize Ref. Asp. Std. A into Meas. Chamber Perform Wash Cycle st try Reference Housing ok? nd try ***CHECK*** REF HOUSING B A 6

33 0 Calibration Sequence () B C Aspir. Std. A into Meas. Chamber At least slope in Range? ***CHECK*** ELECTRODES Standard A detected? **STANDARD A** T DETECTED Slope A-B and A-C ok for all Electrodes? NA K LI READY XX, XX T CAL'D Aspir. Std. C into Meas. Chamber All Std.A volt. reprod.? NA K LI READY XX, XX T CAL'D Standard C detected? **STANDARD C** T DETECTED NA K LI READY Obtain Electrode Voltages Std. C Perform Wash Cycle Aspir. Std. A into Meas. Chamber Standard A detected? **STANDARD A** T DETECTED Obtain Electrode Voltages Std. A Calculation of Std.A-Std.C (Use last Std. A) C

34 Power-up Power-up AVL980 A80X.AA WARM UP All dots lit for / sec. Cold start? Set Time/Date Date: -JAN-95 Time: :00 Power Fail -v-95 : (Print) Pack in place? Global* *Background check in all menus except "Take out of Operation" and "Service Functions" *****PLEASE***** *******WAIT******* (Wash) Perform Daily Cleaning? Perform Daily Conditioning? Remain in Daily Maintenance? min Is Calibration due? Clean/Cond. needed? Clean... Condition... Stabilizing 0 sec. AVL980 A80X.AA WARM UP 59 Clean/Cond. needed? Calibration... Pack in place? Global* Pack inserted? New SnapPak Global* installed? ****STATUS**** ** SnapPak** NA K CA READY *Background check in all menus except "Take out of Operation" and "Service Functions" PRINT FUNCTIONS? Reset counter to 00% QC/STD/DIALYSATE/ URINE SAMPLE? DAILY MAINTENANCE? CALIBRATION? SERVICE FUNCTIONS? PROGRAM INSTRUMENT? OPERATOR FUNCTIONS? 8

35 . Software Operation - 98 Overall Program Operating Flow - 98 Na K Cl READY AUTOMATED MEASUREMENT? Yes Yes * PRINT FUNCTIONS? Yes CALIBRATION? QC/STD/DIALYSATE /URINE SAMPLE? DAILY MAINTENANCE? OPERATOR FUNCTIONS? PROGRAM INSTRUMENT? SERVICE FUNCTIONS? Yes Yes Yes Yes Yes Yes MANUAL MEAS. AUTOM. MEAS. Print last Sample Report? QC Level Sample? Perform Daily Cleaning? Check/Change SnapPak? Enter Code: AAA Test Electrodes? CALIBRATE... Yes Print Last Automated Run? Print Cal. Report? Print QC Values and Statistics? Remain in Print Functions? Yes QC Level Sample? QC Level Sample? Standard Sample? Bicarbonate Sample? Acetate Sample? Urine Sample? Remain in QC/ Std/Urine Sample? Yes Perform Daily Conditioning? Remain in Daily Maintenance? CALIBRATE... Yes Go to Standby Mode? Set Time/Date? Select Parameter Configuration? Reset Sample Number? Take Out of Operation? Remain in Operator Func.? Program QC Level Ranges? Program QC Level Ranges? Program QC Level Ranges? Program rmal Ranges? Program Corr. Factors? Program Bicarb. Corr Factors? Program Acetate Corr Factors? * * Test Sample Sensor? Test SnapPak Sensor? Test Language Switch? Test Probe? Test Sampler? Test Pump? Test Valves? * * Program Urine Corr Factors? Test Interface? Jump Pins & * only with Autosampler plugged in * with Li + off Yes Program Printer Setup? Program Interface? Remain in Program Func.? Yes Test Amplifier? Enter Service Code? Remain in Service Func.? 9

36 Main Menu - 98 MAIN MENU NA K CL READY LEGEND Display prompt AUTOMATED MEASUREMENT? Action performed by analyzer PRINT FUNCTIONS? -second display prompt QC/STD/DIALYSATE/ URINE SAMPLE? Decision-making by analyzer DAILY MAINTENANCE? OPERATOR FUNCTIONS? PROGRAM INSTRUMENT? SERVICE FUNCTIONS? CALIBRATION? 0

37 Manual Measurement Sequence - 98 Na K Cl READY AUTOMATED MEASUREMENT? Probe moves to upper position Please Wait Introduce Sample > air voltage CHECK SS VOLTAGE < air voltage Remove Sample and Wipe Probe Remove Sample and Wipe Probe Retract Probe -> Probe retracts automatically in 0 sec. Retract Probe -> Probe moves to lower position Probe moves to lower position Thank You! Thank You! Serum Sample in Process 9 Blood Sample in Process 9 / min. Na K Cl 5 5. Na K Cl 5 5. / min.

38 Automated Measurement Sequence - 98 Na K Cl READY AUTOMATED MEASUREMENT? Manual Measurement Probe moves to upper position Tray homes Probe moves to upper position Tray moves to applicable cup position Probe moves down to cup position Probe moves to upper position Turntable moves to mid position Probe moves to lower position sample < sample = SAMPLE! CHECK SS VOLTAGE End of Run Sample * in Process Home Tray Na K Cl 5 5. Na K Cl READY * applicable sample number

39 5 Print Functions Menu - 98 PRINT FUNCTIONS? QC/STD/DIALYSATE/ URINE SAMPLE? Print Last Sample Report? PRINTING... Print Last Automated Run? PRINTING... Na K Cl READY Print Cal. Report? PRINTING... Print QC Values and Statistics? PRINTING... Remain in Print Functions? Na K Cl READY

40 6 QC/Standard/Dialysate/Urine Sample Menu - 98 QC/STD/DIALYSATE /URINE SAMPLE? DAILY MAINTENANCE? QC Level * Sample? Probe moves to upper position Please Wait! Introduce Sample Remove Sample Wipe Probe Retract Probe -> Probe moves to lower position min. * same for level - s s VALUES REJECTED! VALUES ACCEPTED! min Store Values? NA K CA READY Na K Ca QC Level * in Process 9 Thank You! Standard Sample? Automated Measurement? Probe moves to upper position Please Wait! Introduce Sample Remove Sample Wipe Probe Retract Probe -> min. Na K Ca Standard Sample in Process 9 Thank You! Probe moves to lower position Bicarbonate Sample? Automated Measurement? Probe moves to upper position Please Wait! Introduce Sample Remove Sample Wipe Probe Retract Probe -> min. Na K Ca Bicarb. Sample in Process 9 Thank You! Probe moves to lower position Acetate Sample? Automated Measurement? Probe moves to upper position Please Wait! Introduce Sample Remove Sample Wipe Probe Retract Probe -> min. Na K Ca Acetate Sample in Process 9 Thank You! Probe moves to lower position Urine Sample? Automated Measurement? Probe moves to upper position Please Wait! Introduce Sample Remove Sample Wipe Probe Retract Probe -> min. Na K Ca Urine Sample in Process 9 Thank You! Probe moves to lower position Remain in QC/ Std/Urine Sample? / min. NA K CA READY

41 Daily Maintenance Menu - 98 DAILY MAINTENANCE? OPERATOR FUNCTIONS? Perform Daily Cleaning? Probe moves to upper position Introduce Sample Cleaning Solution detected? CLEAN Cleaning Solution not detected! Perform Daily Conditioning? Probe moves to upper position Introduce Sample Condition. Solution detected? CONDITION Condition. Solution not detected! Remain in Daily Maintenance? /min. CLEANING AND/OR COND. PERFORMED? 0 SECOND STABILIZATION CALIBRATE NA K CA READY Calibration due? 5

42 8 Operator Functions Menu - 98 *****STATUS***** ** SnapPak** OPERATOR FUNCTIONS? Check/Change SnapPak? PROGRAM INSTRUMENT? % remaining Change SnapPak? Pack detected? GLOBAL* New SnapPak installed? *Background check in all menus except "Take out of Operation?" Fluid Counter reset to 00% Go to Standby Mode ***STANDBY!*** -> READY Maint. due? / New Pack Prime... Set Time/Date? Select Parameter Configuration? Reset Sample Number? Take out of Operation? Remain in Operator Func? Leave Standby Mode? PRESS IS CALIBRATION WITHIN s DUE? Date: 0-FEB-9 Time: :00 ok? Date: 0-FEB-9 Time: :00 ok Are you sure? Shutdown Plug and Water installed? Shutdown Complete Turn Power Off / NA K Daily Cleaning? CLEAN READY SET SAMPLE NUMBER TO 0 Transp Housing Ref installed? Do You Wish to DELETE all Data? Daily Conditioning? CONDITION 0 SECOND STABILIZATION CALIBRATE Sel. Parameter: Sel. Parameter: Sel. Parameter: [Na] [K] [ ] ok? [Na] [K] [Cl] ok? [Na] [K] [Ca] ok? Sel. Parameter: ([Na]) [ ] [Li] ok? Remove Water and Press Pump Windings Relieved? CALIBRATE Na K READY Remain in Daily Maintenance? min/ IS CALIBRATION DUE? New Parameter added? Electrodes in place? Sel. Parameter: [Na] [K] [Li] ok? Sel. Parameter: [Na] [ ] [Li] ok? All Electrodes & Plug Removed? 5 Relief Clamps Inserted? 6

43 9 Program Instrument Menu - 98 PROGRAM INSTRUMENT? SERVICE FUNCTIONS? Enter Code: AAA IN- CORRECT CODE ERROR! RETRY? CORRECT Program QC Level Ranges? Current Lot: 0000 Print old Values New Lot! Change Lot? and Statistics? Delete old Data? Enter last Dig of Lot#: 0000 Additional Parameters? K low =.5 K high = 5.0 ok? Na low = 00 Na high = 05 ok? Enter last Dig of Lot#: 0000 ok? Cl low = 050 Cl high = 00 ok? Ca low = 0. Ca high = 5.0 ok? Li low = 0. Li high = 6.0 ok? Program QC Level Ranges? Program QC Level Ranges? "see Level " "see Level " Program rmal Ranges? Na low = 6 K low = 0.5 Na high = 5 ok? K high = 05. ok? Program Corr Factors Reset Corr Factor (default)? Input/Verify Corr Factors? Remain in Corr Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Bicarb. Corr Factors Reset Bicarb. Factor (default)? Input/Verify Bicarb. Factors? Remain in Bicarb Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Acetate Corr Factors Reset Acetate Factor (default)? Input/Verify Acetate Factors? Remain in Acetate Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Urine Corr Factors Reset Urine Factor (default)? Input/Verify Urine Factors? Remain in Urine Factors? Na (b) = Na (m) =.000 K (b) = K (m) =.000 Program Printer Setup? Patient Report off? Print two Patient Reports? / Automatic Cal Report? / Enter Comment Line? Enter Comment: _ Program Interface? Activate Data Link? / Remain in Program Func? NA K READY

44 0 Service Functions Menu - 98 SERVICE FUNCTIONS? CALIBRATION? *same for Std. A, B, C Test Electrodes? Test Standard A *? Std. A*: Na = 0000 K = 0000 Ca = 0000 Test External Sample? Introduce Sample Retract Probe -> Remain in Test Electrodes? Ext.: Na = 0000 K = 0000 Ca = 0000 Test Sample Sensor? DRY: 80-0: 0 =Pump/=Exit External: 0 Pump: =OFF wash... Test SnapPak Sensor? SnapPak: I I=In O=Out / Test Language Switch? Language Switch English / Test Probe? U = 0 L = Sample Position? Probe moves to extended position U = 0 L = 0 Upper Position? Probe moves to upper position U = 0 L = 0 Cup Position? Tray moves to mid position Probe moves to upper position U = 0 L = 0 Lower Position? Probe moves to cup position Tray moves to cup position Probe moves to lower position U = 0 L = Exit Probe Test? Probe moves to upper position Tray homes Probe moves to lower position Test Sampler? Test Pump? Test Pump! Very slow speed s Test Pump! s Test Pump! s Slow speed Medium speed Test Pump! Fast speed s Test Valves? Test Valve A: /=ON/OFF Test Valve B: Test Valve C: /=ON/OFF /=ON/OFF Test Valve V: /=ON/OFF Test Interface? Jump Pins & -- Test Interface -- Interface ok! Remain in Test Interface? Test Valve R: /=ON/OFF Test Amplifier? Na = -00 K = -00 Cl = -09 Ground = -500mV = -96 Temp (mv) = -60 Temp ( C) = 6. Enter Service Code? Enter Code: Is Code AAA ok? valid? Code Accepted! Enter Other Service Code? Code Error! Retry? Remain in Service Func? Calibration? Calibrate... NA K CA READY 8

45 Calibration Sequence - 98 () (Example Na/K/Li Calibration) CALIBRATION? A Calibration in Process Asp. Std. A into Meas. Chamber Clear Sample Path Standard A detected? **STANDARD A** T DETECTED Calibrate Sample Sensor Obtain Electrode Voltages Std. A Sample Sensor Voltage ok? ***CHECK*** SAMPLE SENSOR Std. A Values obtained? Prime Standard B Are Values reproducible? 6 Aspir. of Std.A performed? Prime Standard C Aspir. Std. B into Meas. Chamber At least Channel reprod.? Prime Standard A Standard B detected? **STANDARD B** T DETECTED ***CHECK*** ELECTRODES All Standards not detected? *********CLOG******** CHECK FLUID PATH Obtain Electrode Voltages Std. B Two Standards not detected? **STANDARD X/Y** T DETECTED Calc. of Std.A- Std.B (slope) Standard A,B,C not detected? **STANDARD X** T DETECTED At least slope in Range? ***CHECK*** ELECTRODES Pressurize Ref. Asp. Std. A into Meas. Chamber Perform Wash Cycle st try Reference Housing ok? nd try ***CHECK*** REF HOUSING B A 9

46 Calibration Sequence - 98 () B C Aspir. Std. A into Meas. Chamber At least slope in Range? ***CHECK*** ELECTRODES Standard A detected? **STANDARD A** T DETECTED Slope A-B and A-C ok for all Electrodes? NA K LI READY XX, XX T CAL'D Aspir. Std. C into Meas. Chamber All Std.A volt. reprod.? NA K LI READY XX, XX T CAL'D Standard C detected? **STANDARD C** T DETECTED NA K LI READY Obtain Electrode Voltages Std. C Perform Wash Cycle Aspir. Std. A into Meas. Chamber Standard A detected? **STANDARD A** T DETECTED Obtain Electrode Voltages Std. A Calculation of Std.A-Std.C (Use last Std. A) C 0

47 Power-up - 98 Power-up AVL980 A80X.AA WARM UP All dots lit for / sec. Cold start? Set Time/Date Date: -JAN-95 Time: :00 Power Fail -v-95 : (Print) Pack in place? Global* *Background check in all menus except "Take out of Operation" and "Service Functions" *****PLEASE***** *******WAIT******* (Wash) Perform Daily Cleaning? Perform Daily Conditioning? Remain in Daily Maintenance? min Is Calibration due? Clean/Cond. needed? Clean... Condition... Stabilizing 0 sec. AVL980 A80X.AA WARM UP 59 Clean/Cond. needed? Calibration... Pack in place? Global* Pack inserted? New SnapPak Global* installed? ****STATUS**** ** SnapPak** NA K CA READY *Background check in all menus except "Take out of Operation" and "Service Functions" PRINT FUNCTIONS? Reset counter to 00% QC/STD/DAILYSATE /URINE SAMPLE? DAILY MAINTENANCE? CALIBRATION? SERVICE FUNCTIONS? PROGRAM INSTRUMENT? OPERATOR FUNCTIONS?

48 . Service Functions The Service Functions mode provides a menu of service test functions to assist in failure diagnosis and identification. A logic flow chart is provided for reference of the sequences included in the Service Functions mode. TEST ELECTRODES This mode allows for the measurement and display of electrode voltages. Standard A, Standard B or an external sample can be measured to determine electrode performance and provide measurement data useful in locating electrode calibration faults. Each electrode parameter will be displayed and the electrode voltage associated with the sample type selected can be observed. Example Displays: Std. A: Na=58 Std. B: Na= K= 65 Cl=-90 K=-988 Cl=6 Ext: Na= K=-598 Cl= - TEST SAMPLE SENSOR In this mode, the sample sensor output is displayed which is useful for electrical adjustment or for troubleshooting sample sensor faults. A dry sample sensor should display a value of 00 with a range of 80 to 0. After verifying a dry sensor, aspiration of a clear fluid (i.e., water) should increase the displayed value by at least 0 units. Example Display: DRY 80-0: 0 External: 5 =Pump/=Exit Pump: =OFF

49 TEST SnapPak SENSOR (980 and 98 only) In this test, the SnapPak Sensor detects whether the ISE SnapPak is in place. "I" indicates that the ISE SnapPak is in place, "O" indicates that it is either not present or not completely seated. Example Display: SnapPak: I I = IN O = OUT TEST LANGUAGE SWITCH (980 and 98 only) This mode displays the language selected for display and printout. To change the selection, set the language switch (located behind printer) to the desired language. The display will indicate the language choice according to the switch setting. To activate a new language, turn the analyzer off and back on with the switch set to the desired language. Example Display: Lanugage Switch English TEST SAMPLE DOOR (except 98) This test verifies the operation of the sample door light gate and its associated circuitry. The display indicates an O or C depending on the position of the door. Example Display: Sample Door: C C:Closed/O:Open

50 TEST PROBE (98 only) This test verifies the operation of the sample probe motor, position sensor and associated circuitry. The "U" represents the output of the upper position sensor, the "L" represents the output of the lower position sensor. Example Display: U = 0 L = Sample Position? TEST AUTOSAMPLER (98 only) This test verifies the operation of the Autosampler turntable assembly. The display indicates the output of both the position and home sensors. te: If the Autosampler is not plugged in or the TABLE PRESENT bit is not activated, this test will not appear under the SERVICE FUNCTIONS menu. Example Display: Home: 0 Pos = TEST PUMP This test turns on the peristaltic pump at each of the four pump speeds. The display indicates for two seconds each pump speed while each pump speed is being tested. Observe that the peristaltic pump changes speed as is indicated on the display. *** Pump Test *** *** Pump Test *** Very Slow Speed Slow Speed *** Pump Test *** *** Pump Test *** Medium Speed Fast Speed

51 TEST PINCH VALVES This test turns on/off each solenoid valve as indicated and is useful to verify both electronic control and mechanical operation of each solenoid valve. TEST INTERFACE The Interface Test can be used to verify correct operation of the RSC serial port. To operate this test, jumper pin and pin of the rear interface connector prior to invoking the test. During the interface test, the analyzer sends out a test string and checks if it is received within a set period of time. If correct operation is observed after completion of the test, INTERFACE OK will be displayed. TEST AMPLIFIER The Amplifier Test displays ground, reference and output voltage of each input amplifier. The values displayed for each electrode channel will be dependent on the electrode inputs and may vary. Display of the ground should read between -0mV and +0mV with the reference voltage reading between -90mV and -50mV. With all inputs open, the display should read +/- 095 for each channel. On the 90/ 980/98, an additional display indicating the temperature voltage and temperature in degrees C is available to verify the temperature adjustment. ENTER SERVICE CODE Service Codes are available and allow additional programming features. Following is a listing of the available Service Codes and functions: Set Reset Service Code Description ALL LLA This service code will enable the Ca ++ value during auto- (98 only) matic serum/blood measurement. Special precautions are necessary to obtain the correct Ca ++ value due to sample exposure to room air. CDC Clears all Service Codes. 5

52 DEC CED Provides one additional digit of resolution for each measured parameter for blood and serum samples. QC and Standard samples are always displayed with high resolution. Urine samples are always displayed in low resolution. ECO OCE Allows the operator to run the instrument in the economy mode. The instrument will enter the STANDBY MODE. This occurs at the time of the next -point calibration when no samples have been analyzed since the last -point calibration. FIF IFI Allows printing of electrode voltages during printout of measurements and calibrations. (not available for 90) LEM MEL This service code will print the last 0 error messages (980/98 only) with the date and time of occurrence. MGL LGM This service code is available only in the model 90/ 980/98 analyzer and enables Ca ++ values to be displayed in mg/dl. The normal mode displays values in mmol/l. QC and Standard results are always displayed in mmol/l. B BON (980 /98only) QCC CCQ This service code disables the beep. When this code is enabled, QC values will be reported in direct ISE measurement instead of flame-equivalent values. In this mode, correlation factors are T applied to the measured values. SFC This code allows the input of a percentage for the ISE (980/98 only) SnapPak TM counter. SLC CLS When this code is set, the current setting of the leasing (980/98 only) counter, which cannot be reset by the operator, is printed on the calibration report. SSC CSS This code toggles needle height to accommodate smaller (98 only) sample cups. In the default setting, the analyzer works with.0 ml cups. To select 0.5 ml sample cups, SSC has to be activated. To return to the default setting, CSS has to be activated. 6

53 CODE FUNCTION ALL Enables Ca ++ during autom. X blood/serum measurement CDC Clears all Service Codes X X X X X DEC Additional display resolution X X X X X ECO Economy Mode X X X X X FIF Cal voltages on display X X X X LEM Last 0 error messages X X printed MGL Display mg/dl X X X B beep X X QCC QC values direct X X X X X ISE measurement SFC SnapPak Counter input X X SLC Set "Leasing Counter" X X SSC Small Sample Cups X ANALYZER RESET WARM-UP BYPASS Press and keys simultaneously and turn power off and back on to provide a total reset of the instrument software. CAUTION! All QC Data and Instrument Programming will be lost. Press and keys simultaneously during instrument warm-up.

54 Description of Modules. Mechanical Assemblies.. Front Door Assembly For the 90, 0, 0 and 80 analyzers, the front door can be removed by moving the analyzer to the edge of a work surface so the analyzer door, when opened, will extend past the edge of the work surface. With one hand, hold the analyzer door near the right side hinge pin and, with the other hand, gently apply pressure to the middle rear area of the door. This will allow the right hinge pin to clear the retaining hole in the main chassis. The door can then be removed from the analyzer. The 98 front panel can be removed by tilting it slightly away from the analyzer and lifting it straight up. The plastic window can also be replaced in the field by gently pressing from the rear of the window and snapping the plastic window out toward the front of the analyzer door. The door magnets cannot be replaced in the field as they are glued in place with conductive adhesive... Needle Unit Assembly Both sample needle and fill port are designed for easy replacement by the user. To remove the fill port assembly for replacement, pull the fill port holder towards the front for easy access. Then, press the two plastic tabs on the fill port to allow removal of the fill port from the fill port holder. The sample needle can also be removed and is supplied as a one-piece assembly including the intake tubing. To remove the sample needle, grasp the needle near the white holder block and pull up to unsnap the sample needle from its position. To replace the assembly, align a replacement sample needle and press the replacement assembly into place. Three screws located on the left side of the assembly hold the needle unit assembly in place. To access the two rear screws, turn power off and remove the rear panel. The rear panel can be moved away from the unit for easier access by unplugging the wire harness from the power supply. The SBC board can now be removed by removing the screws which secure the SBC board and disconnecting the cables on the SBC board. Disconnect the connector to the lamp board which supplies the Door Open signal. The two rear screws which secure the needle unit can now be removed using an Allen wrench. Then, remove the front securing screw, the sample intake tubing and the reagent supply tubing (red tag) from the fill port. The needle unit can now be removed from the front of the analyzer for replacement. Reference the Illustrated Parts diagram in Section 8 for a detailed parts diagram of the needle unit. 8

EasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design

EasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design EasyElectrolytes With EasyElectrolytes, Medica has redefined electrolyte analyzer design Simple yes/no prompted operation, combined with a modular design makes EasyElectrolytes reliable and economical.

More information

Wa r n i n g-wa r n i n g-wa r n i n g

Wa r n i n g-wa r n i n g-wa r n i n g Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment

More information

Products for Health Care

Products for Health Care www.medicacorp.com \EDIC@ Products for Health Care easy inside and out Medica s EasyStat analyzer measures ph, PCO 2, PO 2, Na +, K +, Ca ++, and Hct and calculates additional parameters. Patient parameters,

More information

Contents Attentions... 2 Preparation... 4 Technical Specification... 7

Contents Attentions... 2 Preparation... 4 Technical Specification... 7 Contents Attentions... 2 SAFETY GUIDE... 2 SAFETY PRECAUTIONS... 2 SERVICING... 2 INSPECTION OF ALL ATTACHMENTS... 3 Preparation... 4 FRONT PANEL... 4 REAR PANEL... 4 REMOTE CONTROLLER... 5 USAGE TIPS...

More information

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC: MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC: 4076656 TL-SF1005D TL-SF1008D TL-SF1016D 10/100Mbps Desktop Switch REV: 1.0.0 1910010004 COPYRIGHT & TRADEMARKS Specifications are subject to change without

More information

Documentation on all Paxton products can be found on our web site -

Documentation on all Paxton products can be found on our web site - 08/20/2012 Ins-30019-US Net2 I/O board Paxton Technical Support 1.800.672.7298 Technical help is available: supportus@paxton-access.com Monday - Friday from 02:00 AM - 8:00 PM (EST) Documentation on all

More information

LED FOLDING WORKLIGHT TM

LED FOLDING WORKLIGHT TM LED FOLDING WORKLIGHT TM LED LIGHT POWERSTRIP USB CHARGING ITM. / ART. 689211 Model: LM55812 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide For Network Attached Storage Ver.1.1.0.0320 Table of Contents Notices... 3 Safety Precautions... 4 1. Package Contents... 5 2. Hardware Installation Guide... 6 2.1. Hard Disk Installation...

More information

OPTRON mobile. User Guide. magnified vision. Vers. 2.1AL Magnified Vision, Inc. 2013

OPTRON mobile. User Guide. magnified vision. Vers. 2.1AL Magnified Vision, Inc. 2013 OPTRON mobile User Guide Vers. 2.1AL Magnified Vision, Inc. 2013 magnified vision 2 Before operating this device, please read this user guide thoroughly and retain it for future reference. For questions,

More information

GUIDELINES LAID DOWN BY FCC RULES FOR USE OF THE UNIT IN THE U.S.A. (not applicable to other areas). NOTICE

GUIDELINES LAID DOWN BY FCC RULES FOR USE OF THE UNIT IN THE U.S.A. (not applicable to other areas). NOTICE GUIDELINES LAID DOWN BY FCC RULES FOR USE OF THE UNIT IN THE U.S.A. (not applicable to other areas). NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device,

More information

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A pool/spa control system IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller User s and Installation Guide P/N 520886 - Rev A *520886* i MobileTouch Wireless Controller kit contents The

More information

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev: User Guide TL-SG1005D TL-SG1008D 5/8-Port Gigabit Desktop Switch Rev:2.0.2 7106503707 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide For Network Attached Storage Ver.1.1.0.0517 Table of Contents Notices... 3 Safety Precautions... 4 1. Package Contents... 5 2. Hardware Installation Guide... 6 2.1. Hard Disk Installation...

More information

POWER + - + + - INPUT 2010 INNOVAGE LLC All Rights Reserved. Project Name: ProjectorS35_IM Designer/Studio: INNOVAGE Revision: SET UP AND INSTALLATION RCA cables generally cannot be connected to a TV (unless

More information

PANTONE Formula Scale 3

PANTONE Formula Scale 3 PANTONE Formula Scale 3 Operating Manual Models: PFS3-5-22, PFS3-5-12 PANTONE is the property of Pantone, Inc. Copyright Cherlyn Electronics Limited, 2006 Portions Pantone, Inc., 2000 Introduction The

More information

Perle MCR200 Installation Guide

Perle MCR200 Installation Guide Perle MCR200 Installation Guide P/N 5500322-10 Introduction The Perle MCR200 Chassis is a 2 slot chassis able to accommodate up to 2 Perle Media Converter modules or 1 Media Converter Module and an MCR-MGT

More information

f200 English User Manual Contents

f200 English User Manual Contents f200 English User Manual Contents About this Guide...3 FCC Statement...3 WEEE Notice...3 CE Regulatory Notice...4 Notes on Installation...4 Caution...4 1 Introduction...5 1.1 Features...5 1.2 Package Contents...5

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide Applicable Models: AS6004U Ver.3.0.0 (2017-4-13) Table of Contents Notices... 3 Safety Precautions... 4 1. Package Contents... 5 2. Optional Accessories... 6 3. Hardware Installation

More information

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1 Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1 Warning: To reduce risk of injury, the user must read and understand this user manual before using the laser

More information

BLUETOOTH CLOCK RADIO

BLUETOOTH CLOCK RADIO BLUETOOTH CLOCK RADIO SCR1989BT OPERATING INSTRUCTIONS Please read and follow this instruction manual carefully before using the unit and retain it for future reference SYLVANIA is a registered trademark

More information

Technical Note Series

Technical Note Series Technical Note Series pir SENSOR (T2600) S TN0012-0 0 p I R S e n s o r Page 2 IMPORTANT OPERATION INFORMATION Type BF Equipment Internally powered equipment Continuous operation WARNING Explosion Hazard;

More information

Now with Picture Memory

Now with Picture Memory Intrasonic Technology, Inc. Color Video Door Phone / Intercom Installer s Manual Model No.V304KIT-R Now with Picture Memory Please read this manual carefully before the products are installed.technical

More information

Ball Probe Moisture Meter With Bluetooth

Ball Probe Moisture Meter With Bluetooth User Manual Ball Probe Moisture Meter With Bluetooth Model MR59 Table of Contents 1. Advisories... 3 1.1 Copyright... 3 1.2 Quality Assurance... 3 1.3 Documentation... 3 1.4 Disposal of Electronic Waste...

More information

Port PCI Quick Installation Guide

Port PCI Quick Installation Guide 1394 3-Port PCI Quick Installation Guide Introducing the 1394 3-Port PCI The 1394 3-Port PCI is designed to connect DV camcorders, hard disk drives, scanners, printers and other 1394 audio/video devices

More information

Table of Contents. Federal Communications Commission (FCC) Statement...2

Table of Contents. Federal Communications Commission (FCC) Statement...2 Contents Table of Contents Federal Communications Commission (FCC) Statement...2 Important Safety Instructions...3 Chapter 1 Introduction Features...6 Package Contents...7 Front View and Controls...8 Installing

More information

16-SLOT IN-BAND MANAGEMENT CHASSIS

16-SLOT IN-BAND MANAGEMENT CHASSIS FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS User's Guide. Version 1.6 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

LCD monitor $ *- & 86 LR60441

LCD monitor $ *- & 86 LR60441 LCD monitor B286HK MHL USB 2 USB Acer LCD Monitor Quick Start Guide (QSG) Important safety instructions Please read the following instructions carefully. 1. To clean the LCD monitor screen: Turn off the

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

MODEL : LK-P21B MOBILE PRINTER

MODEL : LK-P21B MOBILE PRINTER SEWOO TECH CO.,LTD. 374-2, Gajang-dong, Osan-si, Gyeonggi-do, 447-210, Korea TEL : +82-31-459-8200 FAX : +82-31-459-8880 www.miniprinter.com MODEL : LK-P21B MOBILE PRINTER P21B Rev. C 11/14 All specifications

More information

5 B&W Rear View System Camera

5 B&W Rear View System Camera 5 B&W Rear View System Camera Instruction Manual MODEL: CA453 www.lorexcctv.com Copyright 2007 LOREX Technology Inc. Thank you for purchasing the Lorex 5 Black & White Rear View System Camera. This system

More information

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! 1170 POS SYSTEM 1170 INSTALLATION GUIDE Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution! This Installation Guide will help you efficiently install the 1170 POS. The document

More information

Bluetooth Karaoke Stage with Dual Microphones and Light Effects

Bluetooth Karaoke Stage with Dual Microphones and Light Effects KSAI567 Bluetooth Karaoke Stage with Dual Microphones and Light Effects Owner s Manual Please keep these instruction for future reference as they contain important information CAUTION: THIS IS NOT A TOY!

More information

USB Port Hub HO

USB Port Hub HO USB 2.0 7-Port Hub INSTRUCTION MANUAL HO97916 www.jascoproducts.com Table of Contents I. INTRODUCTION 3 II. OVERVIEW 4 III. SAFETY INSTRUCTIONS 5 IV. POWER MODE SETTING 6 V. HUB STAND ASSEMBLY 7 VI. HARDWARE

More information

3190 Series Touch Screen POS Workstation

3190 Series Touch Screen POS Workstation 3190 Series Touch Screen POS Workstation INSTALLATION GUIDE Congratulations on your purchase of UTC RETAIL s innovative 3190 Series Touch Screen POS Workstation. The 3190 Series is designed for use in

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

OPERATING INSTRUCTIONS POWERSMART 10 10,000 MAH PORTABLE POWER PLEASE READ BEFORE OPERATING THIS EQUIPMENT

OPERATING INSTRUCTIONS POWERSMART 10 10,000 MAH PORTABLE POWER PLEASE READ BEFORE OPERATING THIS EQUIPMENT POWERSMART 10 10,000 MAH PORTABLE POWER OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT HALO POWERSMART 10 Thank you for choosing HALO. Innovative and easy to use, the HALO POWERSMART

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

CNK600 Cable-Nook Interconnect Box

CNK600 Cable-Nook Interconnect Box CNK600 Cable-Nook Interconnect Box Welcome! We greatly appreciate your purchase of the CNK600 Cable-Nook Interconnect Box. We are sure you will find it reliable and simple to use. Superior performance

More information

User s Manual BeamPod User Manual

User s Manual BeamPod User Manual User s Manual BeamPod General Safety Information 1. Keep the device and packaging materials out of reach of infants and children. 2. Keep the power adapter and other contacts from water, Dry your hands

More information

Optoma NuForce NuForce STA200 STA200 Stereo Amplifier Power Amplifier UserUser s Manual s Manual ALSTANZZ

Optoma NuForce NuForce STA200 STA200 Stereo Amplifier Power Amplifier UserUser s Manual s Manual ALSTANZZ NuForce Optoma NuForce STA200 STA200 Power Stereo Amplifier Amplifier User s User s Manual Manual ALSTANZZ FCC STATEMENTS This device has been tested and found to comply with the limits for a Class B digital

More information

1101 Universal Transmitter

1101 Universal Transmitter INSTALLATION SHEET 1101 Universal Description The 1101 is a two input transmitter that is typically used for door/window applications. The 1101 provides two internal magnetic reed switches and an on-board

More information

PL1500M LCD Monitor USER'S GUIDE.

PL1500M LCD Monitor USER'S GUIDE. PL1500M LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Quick Installation...6

More information

Deluxe In/Out Remote Thermometer with Trend Chart

Deluxe In/Out Remote Thermometer with Trend Chart Deluxe In/Out Remote Thermometer with Trend Chart MODEL: JTR-168LR USER'S MANUAL INTRODUCTION Congratulations on your purchase of the JTR-168LR Deluxe In/ Out Remote Thermometer. The basic package comes

More information

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0429-001 TNP121UL Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the UL Listed TNP121UL, Tilt N Plug Jr. Interconnect Box is greatly appreciated.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Adaptor Model No. CZ-CFUNC1U For your safety Read the following instructions carefully, and carry out secure installation and electrical work. The precautions given in this manual

More information

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter 1 Introduction Thank you for selecting the DDS-12DW benchtop conductivity meter.

More information

USER MANUAL. Model NAME : Anker USB 2.4G Wireless Vertical Mouse MODEL NO. : A VERSION : 0.1 DATE : A User Manual VER: 0.

USER MANUAL. Model NAME : Anker USB 2.4G Wireless Vertical Mouse MODEL NO. : A VERSION : 0.1 DATE : A User Manual VER: 0. USER MANUAL Model NAME : Anker USB 2.4G Wireless Vertical Mouse MODEL NO. : A7809012 VERSION : 0.1 DATE : 2015.10.16 Page 1 of 8 Version. Revised Date PIC Remark # 0.1 16/10/2015 Bob Preliminary Page 2

More information

ENG. LCD Monitor Series Prestigio P TFT Active Matrix LCD Panel User s Manual. Prestigio P1910 1

ENG. LCD Monitor Series Prestigio P TFT Active Matrix LCD Panel User s Manual. Prestigio P1910 1 LCD Monitor Series Prestigio P1910 19.0 TFT Active Matrix LCD Panel User s Manual Prestigio P1910 1 I. Federal Communications Commission (FCC) Statement: This Equipment has been tested and found to comply

More information

User Manual Infinity:One

User Manual Infinity:One User Manual Infinity:One For the latest updates and information, please visit: support.one-education.org Notice The information in this user s manual is protected by copyright laws, all parts of this manual,

More information

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS North American Version REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. 918-290e 09/22/09 The FireGenie TM Remote Control

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will

More information

LP3 Multipurpose Laser Presenter

LP3 Multipurpose Laser Presenter LP3 Multipurpose Laser Presenter User Manual Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS 2 2. PACKAGE CONTENTS 4 3. PART NAMES AND FUNCTIONS 4 4. SETUP AND INSTALLATION 5 5. BASIC OPERATION 5 6.

More information

Monochrome Camera. Features. User manual

Monochrome Camera. Features. User manual Monochrome Camera LTC0330/11 LTC0330/21 LTC0350/11 LTC0350/21 LTC0330/51 LTC0330/61 LTC0350/51 LTC0350/61 Features To obtain the best results from your new camera, read these instructions carefully before

More information

TABLET PC. Quick Start Guide. Model: TVE100 I

TABLET PC. Quick Start Guide. Model: TVE100 I TABLET PC Quick Start Guide Model: TVE100 I Safety Precautions 1. This production is suitable for use in non-tropic areas below 2,000 meters, and the mark in the nameplate indicates the product is suitable

More information

AUD-340 Installation Guide

AUD-340 Installation Guide F0123456789ABC DE AUD-340 Installation Guide INPUTS CONTROL OUTPUT 24V DC 48V LINE 2 AUDIO IR RS232 COM 70V 100V 1 3 DIGITAL L R AUDIO 2.5A MAX TX RX 1 2 3 INPUT SELECT LINE BASS TREBLE MUTE 1 Safety Precautions

More information

CNK200 Cable-Nook Interconnect Box

CNK200 Cable-Nook Interconnect Box CNK200 Cable-Nook Interconnect Box Welcome! We greatly appreciate your purchase of the CNK200 Cable-Nook Interconnect Box. We are sure you will find it reliable and simple to use. Superior performance

More information

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital

More information

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide 888385_01 Install.book Page 1 Wednesday, November 11, 1998 2:45 PM SMDR6 Installation Guide 888385_01 Install.book Page 2 Wednesday, November 11, 1998 2:45 PM 888385_01 Install.book Page i Wednesday, November

More information

PR3400 Series 1.4Mp USB Cameras Hardware Guide

PR3400 Series 1.4Mp USB Cameras Hardware Guide PR3400 Series 1.4Mp USB Cameras Hardware Guide Manufactured by: SPOT Imaging Solutions, a division of Diagnostic Instruments, Inc. 6540 Burroughs Ave. Sterling Heights, MI 48314-2133 USA Toll-Free: 866-604-SPOT

More information

BINDOMATIC 101 DFS Document Finishing System

BINDOMATIC 101 DFS Document Finishing System BINDOMATIC 101 DFS Document Finishing System Operator s Manual Version 2 (2003-02-17) Contents 1. Safety instructions... 3 2. Installation... 4 3. Description... 5 4. How to use the Bindomatic 101 DFS...

More information

HiTi P310W. user manual V_0.1.

HiTi P310W. user manual V_0.1. HiTi P310W user manual www.hiti.com V_0.1 TABLE OF CONTENTS Chapter 1. Important Safety Instruction Environments 1-1 Handling Instruction 1-2 Handling Instruction for Consumable and Printed Output 1-3

More information

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide HARDWARE GUIDE Water Loop Controller C1000 Series Specifications and Operational Guide www.proloncontrols.com info@proloncontrols.com 17 510, rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV. 6.1.6 PL-HRDW-WLC-C1000-C/F-EN

More information

SPK User Manual. 900MHz Wireless Stereo Headphones INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

SPK User Manual. 900MHz Wireless Stereo Headphones INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION INTRODUCTION Thank you for purchasing our 900Mhz compact cordless stereo headphone system that takes advantage of the very latest advances in wireless transmission technology so you SPK-9100 900MHz Wireless

More information

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM PACKAGE CONTENTS After receiving the product, please inventory the contents to ensure you have all the proper parts, as listed below. If anything is missing or damaged, please contact Monoprice Customer

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide Applicable Models: AS3102T/AS3104T/AS3202T/AS3204T Ver.2.5.0128 (2016-1-28) Table of Contents Notices... 3 Safety Precautions... 4 1. Package Contents... 5 2. Optional Accessories...

More information

Electrolyte analyzer i-smart 30

Electrolyte analyzer i-smart 30 Electrolyte analyzer i-smart 30 Overview i-sens electrolyte analyzer, i-smart 30 uses 60 μl of blood sample to measure ions such as Na+, K+, Cl- and hematocrit automatically. Unlike other competitors products,

More information

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

EZ Switch EZ Connect N SMCFS1601/SMCFS2401 EZ Switch EZ Connect N Draft 16/24-Port 11n Wireless Fast Ethernet USB2.0 Adapter Switch SMCFS1601/SMCFS2401 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered

More information

MODEL PORTI-T. (Kiosk&Ticket Printer) Rev. 2.0

MODEL PORTI-T. (Kiosk&Ticket Printer) Rev. 2.0 MODEL PORTI-T (Kiosk&Ticket Printer) Rev. 2.0 WOOSIM SYSTEMS Inc. #501, Daerung Technotown 3th, 448, Gasan-Dong, GeumChun-Ku, Seoul, Korea Tel : +82-2-2107-3700 Fax : +82-2-2107-3707 URL: http://www.woosim.com

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

4 Message Paging System

4 Message Paging System 4 Message Paging System Thank you for choosing Pagertec Thank you for choosing Pagertec as your provider for your wireless paging requirements. We greatly appreciate your confidence in our products. At

More information

Brite Star Symphony of Lights Projector Light Show

Brite Star Symphony of Lights Projector Light Show Page 1 Brite Star Symphony of Lights Projector Light Show Page 2 - Search Symphony of lights projector on Google Play Store/I-tunes to download the app. How to connect your device to projector 1. click

More information

KEYBOARD and MOUSE RECEIVER FROM FIBER OPTIC USER S GUIDE

KEYBOARD and MOUSE RECEIVER FROM FIBER OPTIC USER S GUIDE MANUAL PART NUMBER: 400-0398-002 KEYBOARD and MOUSE RECEIVER FROM FIBER OPTIC USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 INSTALLATION...2 CLEANING...2 FCC / CE NOTICE...2

More information

User Guide. Version 2.

User Guide. Version 2. User Guide Version 2 www.rmepad.com RM epad TM User Guide Please read all instructions carefully before using Please retain these instructions for future reference RM epad TM contains replaceable, rechargeable

More information

Low Profile PCI I/O Quick Installation Guide

Low Profile PCI I/O Quick Installation Guide Low Profile PCI I/O Quick Installation Guide Introducing the Low Profile PCI I/O The Low Profile PCI I/O conforms to the new PCI card form factor standard made for space constrained system designs. Since

More information

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL Model K2500-001 1 THE PECO WAVEPRO WIRELESS SYSTEM Thank you for choosing the PECO WavePRO TM Wireless System (Model K2500-001).

More information

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE PNP415 PNP417 with tabletop cutout installed. MANUAL PART NUMBER: 400-0427-002 PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2

More information

Always there to help you. Register your product and get support at SPA1330. Question? Contact Philips.

Always there to help you. Register your product and get support at   SPA1330. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/welcome Question? Contact Philips SPA1330 User manual Contents 1 Important 2 Safety 2 Notice 3 English 2 Your multimedia

More information

N331 Wireless Mini Optical Mouse User s Guide

N331 Wireless Mini Optical Mouse User s Guide N331 Wireless Mini Optical Mouse User s Guide Mouse 1. Left mouse button 2. Right mouse button 3. Scroll wheel 4. Charge port 5. Battery cover 6. Receiver storage compartment 7. Battery cover release button

More information

icore Kiosk system Installation Guide

icore Kiosk system Installation Guide icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

PrintPAD MC65. User Guide

PrintPAD MC65. User Guide 110288-000 PrintPAD MC65 User Guide TABLE OF CONTENTS PrintPAD MC65 Printer Views...1 Open View...1 Closed View...1 Using Batteries: General Guidelines...1 Installing and/or Replacing Batteries...2 Charging

More information

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch Rev: 1.0.0 7106503213 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES

More information

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual Nature Power Inverters Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w Owner s Manual Modified Sinewave Series True Sinewave Series For safe and optimum performance, the Power Inverter must be

More information

Wireless Inspection Camera and LCD Display Instruction Manual

Wireless Inspection Camera and LCD Display Instruction Manual Wireless Inspection Camera and LCD Display Instruction Manual Caution: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.

More information

Fixed Network Camera Hardware User Manual

Fixed Network Camera Hardware User Manual Fixed Network Camera Hardware User Manual FCS-0032 Ver. 2013/12/04 Table of Contents Precautions 3 Safety Instructions... 5 Introduction 6 List of Models... 6 Package Contents... 6 Physical Description...

More information

AUD-220 Installation Guide

AUD-220 Installation Guide AUD-220 Installation Guide STEREO MONO BRIDGE IR RS232 TX RX MIC 48V LINE L R MIC 1 2 INPUTS 24V DC 1 x 40W @ 8Ω 2 x 20W @ 4Ω LOOP OUTPUTS The Intelix AUD-220 is a 2x20 watt Class D amplifier with 8Ω speaker

More information

PeopleNet Display.4. User Manual

PeopleNet Display.4. User Manual PeopleNet Display.4 User Manual Revision A August, 2013 Important Notice PeopleNet. All rights reserved. PeopleNet. reserves the right to alter the equipment specifications and descriptions in this publication

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

Quick Install Guide. Compex 8 Port Dual Speed Fast Ethernet Switch PS2208B. Version 1.1C

Quick Install Guide. Compex 8 Port Dual Speed Fast Ethernet Switch PS2208B. Version 1.1C Quick Install Guide Compex 8 Port Dual Speed Fast Ethernet Switch PS2208B Version 1.1C R 3 1 Figure 1: PS2208B Top View 2 4 Figure 2: Back Panel View of PS2208B Normal Uplink 7.5V/1.5A 5 6 Figure 3: Side

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

mart atch B502 User Manual

mart atch B502 User Manual mart watch B502 User Manual Congratulations on your new ownership of a Polaroid smart watch. Please read the manual carefully for full understanding of all operations and functions of your new smart watch.

More information

PORTI-SP MODEL. (Panel Printer) Rev. 2.0

PORTI-SP MODEL. (Panel Printer) Rev. 2.0 MODEL PORTI-SP (Panel Printer) Rev. 2.0 WOOSIM SYSTEMS Inc. #501, Daerung Technotown 3th, 448, Gasan-Dong, GeumChun-Ku, Seoul, Korea Tel : +82-2-2107-3700 Fax : +82-2-2107-3707 URL: All specifications

More information

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A Copyright Z-Wave 4-in-1 Multi Sensor Copyright 2015 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system,

More information

IP Set-top Box (STB) Model No.: SP-110. Rev

IP Set-top Box (STB) Model No.: SP-110. Rev IP Set-top Box (STB) Model No.: SP-110 Rev. 1.0 2017.05 1 Contents Attentions... 3 SAFETY GUIDE... 3 SAFETY PRECAUTIONS... 3 SERVICING... 3 INSPECTION OF ALL ATTACHMENTS... 4 Preparation... 5 FRONT PANEL...

More information

KP7 Keypad Quick Install Guide

KP7 Keypad Quick Install Guide KP7 Keypad Quick Install Guide English Thank you for including the KP7, 7 button keypad, as part of the user interface strategy for your customer. The KP7 has been designed to provide years of trouble

More information

Owner s Manual. 5200mAh Mobile Power Bank

Owner s Manual. 5200mAh Mobile Power Bank Owner s Manual 5200mAh Mobile Power Bank Model: UPB-05K2-1U PROTECT YOUR INVESTMENT! Register your product for quicker service and ultimate peace of mind. You could also win an ISOBAR6ULTRA surge protector

More information

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT Lotus DX assembly and operation instructions sit-stand workstation MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT safety warnings 13.6 Kg 30 lbs. 2.2 Kg 5 lbs. safety instructions/warning Read and follow all instructions

More information

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION The Solution Multi-Input Module INSTALLATION INSTRUCTIONS Model: MIM-62 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION MIM-62 connects up to 6 monitored entrapment protection

More information

Cube Camera with Fixed Lens Hardware Manual D11, D12. Ver. 2013/05/17

Cube Camera with Fixed Lens Hardware Manual D11, D12. Ver. 2013/05/17 Cube Camera with Fixed Lens D11, D12 Ver. 2013/05/17 Table of Contents Precautions 3 Safety Instructions... 5 Introduction 6 List of Models... 6 Features and Benefits... 7 Package Contents... 8 Physical

More information

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses.

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses. Camera Quick Install Guide VDMINIIRCB Series Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses. Thank you for purchasing a VDMINIIRCB Series CCTV Surveillance Camera. This Quick Install

More information