Model Number Structure

Size: px
Start display at page:

Download "Model Number Structure"

Transcription

1 Temperature Controllers Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for temperature alarm applications. Universal-input (thermocouple/platinum resistance thermometer) models also available. Clearly visible digital display with character height of. mm. Models available with black in addition to white cases. RoHS compliant. Model Number Structure Refer to Safety Precautions for All Temperature Controllers. Refer to ECS/ Operation for operating procedures. CSM DS_E Model Number Legend Models with Terminal Blocks Control Outputs R: Relay Q: Voltage for driving SSR. Alarm Outputs Blank: No alarm : alarm : alarms. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input). Power Supply Voltage Blank: to VAC D: VAC/VDC. Case Color Blank: Black W: Light gray Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to Ordering Information when ordering. Examples Relay control output, without alarm, thermocouple input, light gray case: -RKJ-W Relay control output, one alarm output, platinum resistance thermometer input, black case: -RP-W

2 Ordering Information List of Models Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: to VAC Size Type Control modes mm Terminal block ON/OFF or PID Alarms Outputs Model with thermocouple Model with platinum resistance thermometer Relay -RKJ-W -RP-W Voltage (for driving SSR) -QKJ-W -QP-W Case Color: Light Gray, Thermocouple, Power Supply Voltage: VAC/VDC Size Type Control modes mm Terminal block ON/OFF or PID Alarms Outputs Model with thermocouple Relay -RKJD-W Case Color: Light Gray, Universal-input, Power Supply Voltage: to VAC Size Type Control modes mm Terminal block ON/OFF or PID Alarms Outputs Model with universalinput (thermocouple or platinum resistance thermometer) Relay -RT Voltage (for driving SSR) -QT Relay -RT Voltage (for driving SSR) -QT (See note.) Relay -RT Voltage (for driving SSR) -QT Note: There is no alarm output mode switch. The default setting for alarm output is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output in initial setting level. For details, refer to the /ECS-U Digital Temperature Controller User s Manual (Cat. No. H-E-). Case Color: Black, Universal-input, Power Supply Voltage: VAC/VDC Size Type Control modes mm Terminal block ON/OFF or PID Alarms Outputs Model with universalinput (thermocouple or platinum resistance thermometer) Relay -RTD Voltage (for driving SSR) -QTD Relay -RTD Voltage (for driving SSR) -QTD (See note.) Relay -RTD Voltage (for driving SSR) -QTD Note: There is no alarm output mode switch. The default setting for alarm output is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output in initial setting level. For details, refer to the /ECS-U Digital Temperature Controller User s Manual (Cat. No. H-E-). Accessories (Order Separately) Protective Cover Rubber Packing Type Model Hard Protective Cover YA-B Terminal Cover YS- Model Note: The Rubber Packing is provided with the Digital Controller. Model E-COV

3 Specifications Ratings Note:. Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.). Models for VAC/DC can also be manufactured. Characteristics Note:. The following exceptions apply to thermocouples. U, L: ± C ± digit max. R: ± C ± digit max. at C or less. The following exceptions apply to platinum resistance thermometers. Input set values,,, for :.% FS ± digit max. Supply voltage to VAC, / Hz VAC, / Hz; VDC Operating voltage range % to % of rated supply voltage Power consumption to VAC: VA VAC: VA, VDC: W Sensor input Thermocouple input type: K, J, L Platinum resistance thermometer input type: Pt, JPt Universal-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt, JPt Control Relay output SPST-NO, VAC, A (resistive load) output Voltage output (for driving the SSR) VDC, ma (with short-circuit protection circuit) Control method ON/OFF or -PID (with auto-tuning) Alarm output SPST-NO, VAC, A (resistive load) Setting method Digital setting using front panel keys Indication method -segment digital display (character height:. mm) and deviation indicators Other functions Setting change prohibit (key protection) Input shift Temperature unit change ( C/ F) Direct/reverse operation Temperature range, Sensor switching (K/J/L, Pt/JPt) Switching is performed between a thermocouple and platinum resistance thermometer for universal-input models. Control period switching -mode alarm output Sensor error detection Ambient operating temperature to C (with no condensation or icing); with -year guarantee: to C Ambient operating humidity % to % Storage temperature to C (with no condensation or icing) Setting accuracy Thermocouple (See note.): (±.% of indication value or ± C, whichever is greater) ± digit max. Indication accuracy Platinum resistance thermometer (See note.): (±.% of indication value or ± C, whichever is greater) ± digit max. (ambient temperature of C) Influence of temperature R thermocouple inputs: (±% of PV or ± C, whichever is greater) ± digit max. Influence of voltage Other thermocouple inputs: (±% of PV or ± C, whichever is greater) ± digit max. Platinum resistance thermometer inputs: (±% of PV or ± C, whichever is greater) ± digit max. Hysteresis (for ON/OFF control).% FS (.% FS for universal-input (thermocouple/platinum resistance thermometer) models) Proportional band (P) to C (automatic adjustment using auto-tuning/self-tuning) Integral time (I) to, s (automatic adjustment using auto-tuning/self-tuning Derivative time (D) to, s (automatic adjustment using auto-tuning/self-tuning) Alarm output range Absolute-value alarm: Same as the control range Other: to input setting range full scale ( C or F) Alarm hysteresis:. C or F (fixed) Control period / s Sampling period ms Insulation resistance MΩ min. (at VDC) Dielectric strength, VAC, / Hz for min between current-carrying terminals of different polarity Vibration Malfunction to Hz, m/s for min each in X, Y, and Z directions resistance Destruction to Hz,.-mm single amplitude for hr each in X, Y, and Z directions Shock resistance Malfunction m/s min., times each in directions Destruction m/s min., times each in directions Life expectancy Electrical, operations min. (relay output models) Weight Approx. g (Controller only) Degree of protection Front panel: Equivalent to IP; Rear case: IP; Terminals: IP Memory protection EEPROM (non-volatile memory) (number of writes:,,) EMC EMI Radiated: EN Group Class A EMI Conducted: EN Group Class A ESD Immunity: EN --: kv contact discharge (level ) kv air discharge (level ) Radiated Electromagnetic Field Immunity: EN --: V/m (- MHz,.-. GHz amplitude modulated) (level ) V/m ( MHz pulse modulated) Conducted Disturbance Immunity: EN --: V (. to MHz) (level ) Noise Immunity (First Transient Burst Noise): EN -- Burst Immunity: kv power-line (level ), kv I/O signal-line (level ) Surge Immunity: EN --: Power line: Normal mode kv; Common mode kv Output line (relay output): Normal mode kv; Common mode kv Voltage Dip/Interrupting Immunity: EN --. cycle, % (rated voltage) Approved standards UL - (listing) CSA C. No.- Conformed standards EN, EN -, IEC - VDE Part (finger protection), when the terminal cover is mounted.

4 Temperature Range Thermocouple Input Models Temperature range (selected using switch) (Default setting: ) Input K J/L, Setting number Minimum setting unit C C Platinum Resistance Thermometer Input Models Temperature range (selected using switch) (Default setting: ) Input.. JPt/Pt.... Setting number Minimum setting unit C. C C. C C. C The shaded value indicates the default setting status. The shaded value indicates the default setting status. Universal-input (Thermocouple/Platinum Resistance Thermometer) Models Using Thermocouple Sensors, Control Mode Switch : OFF Input K J L T U N R,,,, Temperature range,,,,,, (selected, using switch) (Default setting: ) Setting number Minimum setting unit C. C C. C C. C C Using Platinum Resistance Thermometers, Control Mode Switch : ON Temperature range (selected using switch) (Default setting: ) Input Pt JPt,.... Setting number Minimum setting unit C. C C. C C The shaded value indicates the default setting status. The shaded value indicates the default setting status.

5 External Connection Diagram Voltage output models (See note.) Relay output models Alarm output Voltage output Relay output VDC, ma Alarm output (See note A Alarm output (See note B B to VAC, / Hz ( VAC/VDC) (See note.) Platinum resistance thermometer input Thermocouple input Thermocouple/ platinum resistance thermometer universal-input Note:. The voltage output ( VDC, ma) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not connect output terminals or to ground. Otherwise, unwanted current paths will cause measurement errors.. Models with to VAC and VAC/VDC are separate. Models using VDC have no polarity.. The number of alarm outputs depends on the model. Nomenclature Models with Terminal Blocks Deviation indicators Mode indicators Output indicator Temperature display Alarm indicators Mode Key Lock Release Key Up Key Down Key

6 Dimensions Note: All units are in millimeters unless otherwise indicated. Controller Panel Cutout Dimensions +. L min. + L = ( N.) Mounting side-by-side (group mounting of N Controllers) Note: Terminals cannot be removed. + Adapter for Flush Mounting (Provided) Adapter for flush mounting Panel YF- Adapter for flush mounting. Tightening screws. Note:. The recommended panel thickness is to mm.. Group mounting is possible in one direction only. Accessories (Order Separately) Hard Protective Cover The YA-B Protective Cover (hard type) is available for the following applications. To protect the set from dust and dirt. To prevent the panel from being accidentally touched causing displacement of set values. To provide effective protection against water droplets. C A-B Terminal Cover Rubber Packing E-COV.. YS- (for DIN ) Order the Rubber Packing separately if it becomes lost or damaged. The Rubber Packing can be used to achieve an IP degree of protection for models with terminal blocks. (Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Rubber Packing does not need to be attached if a waterproof structure is not required.

7 Safety Precautions Refer to Safety Precautions for All Temperature Controllers. Refer to ECS/ Operation for operating procedures. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.. To convert grams into ounces, multiply by.. In the interest of product improvement, specifications are subject to change without notice.

8 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation All Right Reserved.

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input) Temperature Controllers CSM DS_E Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. s with two alarms added to Series, ideal for temperature

More information

Model Number Structure

Model Number Structure Temperature Controllers ECS CSM_ECS_DS_E Simple Functions in DIN mm-size Plug-in Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for applications requiring

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Model Number Structure

Model Number Structure Temperature Controller CSM DS_E_5_1 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_1 I/O SSRs That Mount to OMRON s G7TC I/O Block Input and output modules are available in wide variety. Snaps easily into P7TF I/O Terminals and can be used together with

More information

Model Number Structure

Model Number Structure Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_4_2 International Standards for G3F Series, Same Profile as MY Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (model numbers

More information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2. Terminal SSR G3S CSM_G3S_DS_E_7_ Compact Terminal SSR with Outputs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Easy wiring with separate I/O terminal

More information

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Solid-state Timer Solid-state Timer with Variable Time Ranges Four time ranges are selectable per timer unit. Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer

More information

Model Number Structure

Model Number Structure Solid-state Twin Timers CSM DS_E_1_5 DIN 48 48-mm Twin Timers Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. ON- and OFF-times can be set independently and so combinations of

More information

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm Digital Amplifier Ultrasonic Sensor CSM DS_E_1_1 A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Compact with a Broad Selection of Side-view Heads Slim with analog outputs

More information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21 Solid-state timer CSM DS_E_3_2 Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

NPN output. 200 mm. Type Cable length Model Remarks

NPN output. 200 mm. Type Cable length Model Remarks Retroreflective Photomicrosensor with Lens CSM DS_E_5_2 Photomicrosensor with light modulation for reduced external light interference. Easy adjustment and optical axis monitoring with a light indicator.

More information

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4. PCB Sensors ES-LS@ CSM_ES-LS DS_E_5_2 Reliable Detection Unaffected by PCB Holes or Notches High-limit ES-LS@ is suitable for incorporation in devices. Wide-range ES-LS@W is ideal for detecting tall components

More information

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure Mechanical Touch Switch D5B CSM_D5B_DS_E_3_2 Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics Slow-action switching mechanism used. Gold-plated contact with coil spring

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0. Incremental 25-mm-dia. Rotary Encoder CSM DS_E_5_1 Compact Encoder with External Diameter of 25 mm Incremental model External diameter of 25 mm. Resolution of up to ppr. Be sure to read Safety Precautions

More information

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor Flat Capacitive Sensor with Separate Amplifier Ideal for Mounting on Robot Hands. Flat head is only 5.5-mm thick. Robotics cable ensures

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Small General-purpose Photoelectric Sensor with Built-in Power Supply Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only 50 x 50 x

More information

E2K-X4ME1 2M E2K-X4ME2 2M

E2K-X4ME1 2M E2K-X4ME2 2M Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Sensor That Detects Metals and Non-metals Alike Detects both metallic and nonmetallic objects (water, oil, glass, plastic, etc.).

More information

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2 Thumbwheel Switch ABS/ABL CSM_ABS_ABL_DS_E Wide Range of Locking-type s Available Character height of. or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated High-precision Optical Switch D5F CSM_D5F_DS_E_2_2 Optical System Achieves 1-μm Operating Position Repeatability in this 4-way Switch No-contact structure for high reliability. Ceramic materials in measuring

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_4_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC Solid State Relay G3MC Compact, Thin-profile, Low-cost SSR with Reinforced Insulation Small bottom surface area (approx. 80% of the conventional G3MB s), ideal for close PCB mounting. DC input and AC output

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal.

More information

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC Solid-state Timer CSM DS_E_4_1 Miniature Timer Compatible with the MY Relay Semi-multi power supply voltage. Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver

More information

Handheld Reader Writer

Handheld Reader Writer Handheld Reader Writer CH1D-V2 A Compact Lightweight Easy-to-use Pen-type Reader Writer. Connects directly to a personal computer or PLC via RS-232C. The Reader Writer s protective construction is IP63

More information

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series CJ/CS Series ID Sensor Unit CJ1W-V680C11/-V680C12 CS1W-V680C11/-V680C12 CSM_C_1W-V680C1_DS_E_1_1 Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series Communication

More information

Intelligent Flag Amplifier

Intelligent Flag Amplifier V0 RFID System V0-HAM42-DRT Intelligent Flag Amplifier for CompoBus/D System Configuration Master Unit Master Unit CompoBus/D ( -compatible) I/O I/O V0-HAM42-DRT (Amplifier) V0-HS@@ (Sensors) V0-D@@ (Data

More information

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series Ordering Information Sets of Sensor Head and Amplifier Unit Type NPN Narrow View/Single Function ZFV-R1010 ZFV-R1015 Narrow View/Standard ZFV-R1020

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs. CJ-series Interrupt Input Units CSM DS_E 1 High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 3 Interrupt Inputs. Receive inputs to start I/O interrupt tasks. When the

More information

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Aluminum-detecting Proximity Sensor (Separate Amplifier Type) Aluminum-detecting Proximity Sensor (Separate Amplifier Type) ECY Simple Teaching Function for Simple Adjustment. Easy-to-see Excess Gain Level Indicators. Detects aluminum, copper, and other non-ferrous

More information

Model Number Structure

Model Number Structure Temperature Meter CSM DS_E_6_1 Highly Visible LCD Display with 2-color (Red and Green) LEDs Wide input range - select from two types of platinum-resistance thermometers and ten types of thermocouples.

More information

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure Safety Relay Unit G9 CSM_G9_DS_E The G9 Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay

More information

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor. Slot-type Photomicrosensor EE-SX CSM_EE-SX_DS_E Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. A built-in connector minimizes the shape and dimensional

More information

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE SYSMAC Option CSM DS_E_1_1 The RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. The connects directly to a CS/CJ-series RS-232C port and converts RS-232C to RS-422A/485. Features

More information

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information Photomicrosensor with Slim Cable (Non-modulated) EE-SX77/87 CSM_EE-SX77_87_DS_E_7_2 Slim, Compact Photomicrosensor that is still easy to use. Compact, thin profile enables dense mounting. Indicator is

More information

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC Reverse Protection Relay CS DS_E Uses Voltage Detection to Determine Reverse Revolution of Three-phase otor Detects motor reversal due to incorrect wiring. Direction of motor revolution is detected as

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G@-VD CSM_GH_GHD_DS_E_6_ New Models with International Standards Added to GH Series (-VD in model number). Same Profile as LY and LY Bi-power Relays Certified by UL, CSA, and VDE (models

More information

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models Interface Converter CSM DS_E 1 A compact converter that allows communications between /USB and RS-/ devices. Ideal for industrial applications. Allows communications between /USB (Universal Serial Bus)

More information

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_5_3 International Standards for G3F Series, Same Profile as MY Power Relays Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier Small Spot/Mark Sensor with Built-in Amplifier CSM_E3S-GS_VS_DS_E_2_1 Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors Be sure to read Safety Precautions on page. Ordering

More information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22. Measuring and Monitoring Relays CSM_K8AB_series_Outline_DS_E_3_2 Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions.

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Model NPN output PNP output Standard. configuration

Model NPN output PNP output Standard. configuration Slot-type Photomicrosensor (Non-modulated) *1 EE-SX4/6 CSM_EE-SX4_6_DS_E 1 Global Standard Slot-type photomicrosensors with 0- to 100-mA direct switching capacity. Series includes models that enable switching

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend. Switch Mode Power Supply (3/7.5/15/30/50/90/100-W Models) CSM DS_E_3_1 Ultimate DIN-rail-mounting Power Supply with a Power Range of 3 to 100 W EMI: EN 61204-3 class B Input: 85 to 264 VAC (except 90-W

More information

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch. Indicator (Cylindrical 16-dia.) CSM DS_E_6_1 Cylindrical 16-dia. Indicator Same basic design as the A16 Pushbutton Switch. Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions

More information

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units. Sensor Communications Unit CSM DS_E_1_1 The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation Low initial cost achieved by distributed

More information

Model Number Structure

Model Number Structure Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with analogue setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12 ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12 Integrate Supply Chain Management with Work-in-Process Data Collection by RFID on the PLC Rack These Modules can be combined with OMRON s comprehensive

More information

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information Cable Amplifier Proximity Sensor EEC CSM_EEC_DS_E High-sensitivity DC -Wire Sensors and Subminiature Sensors with Long-distance Detection Shielded Sensor Heads from -mm to M diameters that can be embedded

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Switching Frequency Test Conditions (AC3/AC4/AC53-a) Information Common to the G3J-T, G3J-S, and G3J CSM_G3J-T_G3J-S_G3J_common_DS_E_2_2 Engineering Data Load Current vs. Ambient Temperature Load current Io (A) G3J-T217BL G3J-T211BL G3J-S211BL G3J-211BL

More information

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Name No. of I/O points Model Safety inputs: 12, test outputs: 4 Safety I/O s DST1 Series CSM_DST1 Series_DS_E_7_3 Distributed Safety s That Reduce Wiring. Lineup includes four models to accommodate various I/O types and number of I/O points. Monitor the safety system

More information

Limit Switch Connectors

Limit Switch Connectors CSM_LimitSwitch DS_E s (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s also

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_1 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.

More information

Limit Switch Connectors

Limit Switch Connectors CSM_LimitSwitch_Connector_DS_E Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

Model A7BS

Model A7BS Thumbwheel Switch ABS/ABL CSM_ABS/ABL_DS_E Wide Range of Locking-type s Available Character height of.8 or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time Ground Fault Relay CSM DS_E_9_3 Economical, Compact, High-performance, DIN 8 8-mm Ground Fault Relay for Low Voltages Performs continuous monitoring and detection of ground faults in low-voltage circuits

More information

Peripheral Devices for Environment-resistive Slaves

Peripheral Devices for Environment-resistive Slaves Peripheral Devices for Environment-resistive Slaves Peripheral Devices for DeviceNet Communications Ordering Information Environment-resistive Connection Products (for Thin Cable, M Micro Connectors) Product

More information

Three-phase Phase-sequence Phase-loss Relay

Three-phase Phase-sequence Phase-loss Relay Three-phase Phase-sequence Phase-loss Relay K8AB-PM Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. Monitor overvoltages, undervoltages, phase sequence, and phase loss

More information

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model Small Spot/Mark (Separate Amplifier) EC-VS/VM CSM_EC-VS/VM_DS_E_6_ Extremely thin beam ideal for detection of minute objects and marks Ideal for detection of small objects and slight color differences

More information

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A High-precision Switch CSM DS_E_2_2 High-precision Switch for Detecting Micron-unit Displacement Ideal for detecting and measuring wear of cutting tools or for original point of work. Ceramic plungers on

More information

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output Solid-state Timer H3FA Please read and understand this catalog before purchasing the products. Please consult OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1 Common to all H3CR Note: The undermentioned is common for all H3CR models. Basic Setting Setting of Selectors The s can be turned clockwise and counterclockwise to select the desired time unit, time range,

More information

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models Interface Converter CSM DS_E 1 A compact converter that allows communications between /USB and RS-22/8 devices. Ideal for industrial applications. Allows communications between /USB (Universal Serial Bus)

More information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H Solid-state Timer CSM DS_E_3_1 DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display Dual power supplies for free AC/DC. Eight operation modes selectable with one unit. Any desired

More information

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1 Switch Mode Power Supply (10/25/50/100/150/300/600-W Models) CSM DS_E_3_1 Low-cost Global Power Supply with CE Marking Safety standards: UL: UL508 (Class 2), No.60950-1, cul: CSA C22.2 No. 14 (Class 2),

More information

Model Number Structure

Model Number Structure Analogue Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0 Safety Network Controller CSM_NE1A-SCPU0_-EIP_DS_E_1_1 Directly Connected to SYSMAC CS/CJ Series via EtherNet/IP Monitors safety systems via EtherNet/IP. Equipped with master functions of DeviceNet Safety.

More information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information Cable Amplifier Proximity Sensor EEC CSM_EEC_DS_E_8_ Subminiature Sensors with Long-distance Detection Shielded Sensor Heads from -mm to M diameters that can be embedded in metal. Robotics cables provided

More information

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure Multi-beam, finger and hand protection safety sensor Multi-beam, finger- and hand protection safety sensor The multi-beam sensors are available in Type 2 (PL c) and Type 4 (PL e) with integrated muting

More information

Model Number Structure

Model Number Structure Motor Timer CSM DS_E_2_2 DIN-sized 48 x 48 Motor Timer with Simple Operation for Switching Time Specifications Three Motor Timers cover the wide time range of 6 s to 30 h with easy operation from the operation

More information

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001 NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O

More information

Model Number Structure

Model Number Structure Process Meter CSM DS_E_3_1 Highly Visible LCD Display with 2-color (Red and Green) LEDs Multi-range DC voltage/current input. Front-panel key operation for easy setting. Average processing function suppresses

More information

CSM_PYF S/P2RF- -S_DS_E_2_5

CSM_PYF S/P2RF- -S_DS_E_2_5 Screwless Clamp Terminal Sockets PYF@@S/P2RF-@@-S CSM_PYF S/P2RF- -S_DS_E_2_5 New Screwless Terminal Sockets Added for MY and G2R Relays. Simplified wiring without tightening screws. Two wires can be independently

More information

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction. All Metals and Long- Types CSM DS_E and Both Detectable from Long Distances times the aluminum detection of previous models Twice the max. Equipped with a function to prevent the detection of aluminum

More information

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W Axial Interface Unit CK3W-AX Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W-AX Features One CK3W-AX Unit controls up to four axes Analog input type

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C Proximity Ideal for High Temperatures and Cleaning Processes EEH CSM_EEH_DS_E Proximity Ideal for the Food and Beverage Industry SUS6L Body, IP69K Protection, Resistant to High Temperatures and Detergents

More information

Single-phase Voltage Relay

Single-phase Voltage Relay Single-phase Voltage Relay K8AB-VW Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages and undervoltages simultaneously. Separate settings and outputs supported

More information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information Grooved-type with Built-in Amplifier EZ-G CSM_EZ-G_DS_E_9_ with Grooved Design and Easy Settings Groove-type with groove width of 5 mm. Models are available with one or two light axes. Models are available

More information

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure Indicator (Cylindrical 22/25-dia.) CSM DS_E_3_4 Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Same type as the A22-series Pushbutton Switches. Use 25-dia. ring to install in 25-dia.

More information

DeviceNet Communications Unit Enables Program-free Communications with Temperature Controllers. DeviceNet Communications Unit E5ZN-DRT

DeviceNet Communications Unit Enables Program-free Communications with Temperature Controllers. DeviceNet Communications Unit E5ZN-DRT ommunications Unit -DRT SM_-DRT_DS_E_3_1 Streamlined ommunications from Temperature ontroller to PL The Modular Temperature ontroller is connected to the network. The I/O link function allows setting and

More information

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs I/O Terminal Socket PTF-IS/OS/OS CSM_PTF-IS_OS_OS_DS_E I/O Terminal Sockets to Flexibly Build Systems Mount either GT I/O Relays or GTA SSRs. Compact size for both Input and Output I/O Terminal Sockets:

More information

E4C-UDA CSM_E4C-UDA_DS_E_12_2

E4C-UDA CSM_E4C-UDA_DS_E_12_2 Digital Amplifier Ultrasonic Sensor E4C-UDA CSM_E4C-UDA_DS_E_12_2 Compact, Cylindrical Reflective Ultrasonic Sensor with Easy Setting Stable operation for a variety of objects regardless of color, transparency,

More information