General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications GS 32Q01B20-31E Safety Instrumented System Overview (for V net) [Release 3] GENERAL The is a Safety Instrumented System that is certified by the German certification organization, Technische Überwachungs-Verein (TÜV) to meet Safety Integrity Level (SIL) 3 specified in IEC This GS explains the components and system specifications of the system. COMPONENTS AND SOFTWARE The system is composed of the Safety Control Station (), the Safety Engineering PC (SENG). communicates with each of those equipment via V net control network and Ethernet. The performs safety control, and the SENG performs engineering and maintenance for the. The ProSafe- RS can be integrated with the CENTUM VP and CENTUM CS 3000 R3 (hereinafter, ), an integrated production control system. The can be operated and monitored by the HIS (human interface station) of the. For specifications regarding the, refer to its general specifications. For specifications regarding the system on Vnet/IP, refer to the general specifications (GS 32Q01B10-31E) for Safety Instrumented System Overview (for Vnet/IP). Safety Engineering PC (SENG) To configure the ProSafe system, the CHS5100 Safety System Generation and Maintenance Package needs to be installed on a PC (IBM PC/AT-compatible computers). The SENG performs engineering and maintenance. For details on the SENG s functions, refer to the general specifications (GS 32Q04C10-31E) for the CHS5100 Safety System Generation and Maintenance Package. Safety Control Station () The offers a safety control functions, the sequence-of-events-recorder (SOER) function, the integration function, and the Modbus connection function which interfaces the with another system. The consists of a safety control unit (CPU node) and safety node units (I/O node). There are two types of CPU nodes: a standard safety control unit and a wide range temperature safety control unit (equipped with a fan unit). The CPU node can be connected with the I/O node via the ESB bus. I/O modules can be mounted both on the CPU node and I/O node alike. Standard Type SSC10S-S (model name): Safety Control Unit (for V net, Rack Mountable Type, Standard Type) SSC10D-S (model name): Duplexed Safety Control Unit (for V net, Rack Mountable Type, Standard Type) Wide Range Temperature Type SSC10S-F (model name): Safety Control Unit (for V net, Rack Mountable Type, Wide Range Temperature Type) SSC10D-F (model name): Duplexed Safety Control Unit (for V net, Rack Mountable Type, Wide Range Temperature Type) For details, refer to the general specifications Safety Control Units, Duplexed Safety Control Units (for V net, Rack Mountable Type) (GS 32Q06D30-31E). Basic Software CFS1100 Safety Control Functions Package For details of the CFS1100, refer to the general specifications Safety Control Functions Package (GS 32Q03B20-31E). Yokogawa Electric Corporation , Nakacho, Musashino-shi, Tokyo, Japan GS 32Q01B20-31E Copyright July 2011 (YK) 4th Edition Nov. 28, 2012 (YK)

2 2 Peripheral Equipment For details, refer to the general specifications for the respective hardware below. Items Models General Specifications Safety Node Unit SNB10D GS 32Q06K10-31E I/O Modules GS 32Q06K20-31E Communication Modules ALR111, ALR121 GS 32Q06K50-31E Unit for Optical Bus Repeater Module SNT10D GS 32Q06K11-31E Optical ESB Bus Repeater Module SNT401, SNT501 GS 32Q06L16-31E Cables GS 32Q06M10-31E V net Interface Card VF702 GS 33K55C10-50E Optical Bus Repeater for V net YNT511D, GS 33K55D30-50E, GS 33K55D40-50E Bus Repeater for V net YNT512D GS 33K55D50-50E Power Supply Bus Unit AEPV7D GS 33K50K41-50E Related Software For details, refer to the general specifications for the respective software application below. Items Models General Specifications CENTUM VP Integration Engineering Package CHS5200 GS 32Q04D10-31E SOE Viewer Package CHS2100 GS 32Q02D10-31E SOE OPC Interface Package CHS2200 GS 32Q05D10-31E Access Control and Operation History Management Package Document For details, refer to the general specification below. CHS5170 GS 32Q04D30-31E Item Model General Specification Electronic Document CHS5400 GS 32Q01W10-31E

3 3 SYSTEM CONFIGURATION Minimum System Configuration The minimum system configuration is composed of the following equipment: SENG: 1 unit : 1 unit Maximum System Configuration SENG and : 64 units Example Configuration of CENTUM Integrated System Integrated with the, the system can be configured in any size. The number of interconnected domains (*1): 16 The number of connectable stations in one domain: 64 The number of stations in multi-domain system: 256 Hierarchy: three-level (three control-bus levels linked by two bus converters) Connecting device (*2): bus converter (BCV), communication gateway (CGW) and V net Router (AVR10D) *1: A group of system components, which is configured without BCV, CGW and AVR10D, is one domain. *2: For details, refer to the general specifications document for the bus converter (BCV), communication gateway (CGW) and Duplexed V net Router (AVR10D). Domain 4 Ethernet HIS/ENG SENG Domain 2 Ethernet HIS/ENG SENG Vnet/IP FCS Duplexed V net Router AVR10D Domain 1 Solution package CGW Wide area network FCS V net SENG Ethernet HIS Ethernet HIS/ENG CGW V net Repeater YNT512D V net FCS FCS Optical repeater YNT5xxD Optical repeater YNT5xxD V net BCV FCS Domain 3 V net Figure Example Configuration of the and Integration System In the integration of and, refer to the system specifications for the (GS 33K01A20-50E, GS 33Q01B10-31E) and Safety Instrumented System Overview (for Vnet/IP) (GS 32Q01B10-31E). For integration, the version of the CS 3000 must be R3.06 or later. The number of safety control stations are not included in that of control stations of the LHS1100 Standard Operation and Monitoring Function. F01E.ai GS 32Q01B20-31E July 21,

4 4 engineering is performed from SENG. FCS and HIS engineering are performed from ENG which is a PC for engineering. Engineering of CENTUM integration function is performed from both SENG and ENG. SENG functions, ENG functions and HIS functions can be installed together in a single PC(*1) or separately in several PCs. *1: When R2.xx and CENTUM VP R4.02 or later is installed in the same PC, must be R2.03 or later. In the integration of R3 and CS 3000, SENG functions and ENG functions, or SENG functions and HIS functions cannot be installed in the same PC. For more detail, please contact our sales representative or your local distributor. When a project including is connected as lower level project by using Multiple Project Connection Package (GS 33K05K20-50E), the upper level project must be CENTUM VP, or CS 3000 R3.06 or later. Example of the Connection with Another System can communicate with other systems through Modbus connections. The following functions are available using an interference-free serial communication module. Subsystem communication function can communicate as a master station when acts as a Modbus master. Modbus slave communication function can communicate as a slave station when the other system acts as a Modbus master. The subsystem communication and modbus slave communication functions can be executed simultaneously; however, subsystem communication function and modbus slave communication function cannot coexist on one serial communication module. For communication specifications, refer to Safety Control Functions Package (GS 32Q03B20-31E) and ALR111/ ALR121 Serial Communication Module (GS 32Q06K50-31E). An example of the system configuration is shown below: SENG V net... Modbus communication... The other system (DCS, etc.) F02E.ai Cautions for System Configuration The maximum number of units to which Inter- safety communication is possible from one unit is 16 (when any two units perform bidirectional communication each other, the number of units is counted as 2). For the system to employ a bus converter (BCV), a communication gateway (CGW), and Duplexed V net router (AVR10D), the engineering function of the is needed. Setting IT security function The security can be enhanced through the automatic setting at IT security function of. To perform this operation, the integrated CENTUM VP needs to be R4.01 or later, PRM needs to be R3.02 or later.

5 5 NETWORK SPECIFICATIONS The uses V net and Ethernet for communications among configured devices. V net The V net is a real-time control network that connects system stations. Communication Specifications The number of connectable devices: 64 per domain Communication method: read-write communication, message communication, inter- safety communication, link transmission Line access control: token passing method Transmission Network Specifications Network structure: bus type Transmission channel redundancy: dual-redundant type Network speed: 10 Mbits/sec. Network cable: For coaxial cable (YCB111: 10BASE-5; YCB141: 10BASE-2): The SENG and the are connected via the YCB141. When connecting YCB111 and YCB141, use a Bus Adapter Unit (YCB147 and YCB149) or V net Bus Repeater (YNT512D). Fiber-optic cable: The V net optical bus repeater (YNT511D or ) needs to be used. Transmission distance: For coaxial cables (YCB111 and YCB141): Maximum transmission distance: 500 m for the YCB111 and 185 m for the YCB141. When the YCB141 is used alone, the number of connectable stations is 30 per segment. (*1) When the YCB141 and YCB111 are used together, the transmission distance is: (length of YCB141) (length of YCB111) 185 m. In such cases, the maximum number of conversion units is 4 per segment (*1), and the number of connectable stations is 30 per segment. *1: When the V net is connected via bus repeaters or optical bus repeaters, definition of a segment is an area segmented by repeaters. For Bus Repeater and Optical Bus Repeater: Maximum extension distance per bus repeater (YNT512D) is 500 m. Maximum extension distance for a pair of optical bus repeater (YNT511D) is 4 km. Maximum extension distance for a pair of optical bus repeater () is 15 km. Maximum number of bus repeater and optical bus repeater mountable between any two stations is 8. Optical bus repeater; however, must be used in pairs. Transmission distance is limited by the number of bus repeater. L = 24 - n L: transmission distance (km) n: number of bus repeater and optical bus repeater GS 32Q01B20-31E July 21,

6 6 Total transmission distance is the lesser of the sum of the maximum extension distance for each device and coaxial cable length, or L, calculated above. Calculation example of transmission distance in optical bus repeater connection is shown below. SENG/HIS001 SENG/HIS002 YNT511D YNT511D F04E.ai Figure Example of Optical Bus Repeater Connection Example 1: From SENG/HIS001 to 001 When a pair of optical bus repeater for 15 km is mounted, transmission distance depending on the number of bus repeater and optical bus repeater = 24-2 = 22 km, the sum of the maximum extension distance for each device and coaxial cable length = = 16 km. Therefore, the total transmission distance is 16 km. Example 2: From SENG/HIS001 to 004 When 4 optical bus repeaters (one pair of 4 km and one pair of 15 km) are mounted, transmission distance depending on the number of bus repeater and optical bus repeater = 24-4 = 20 km, the sum of the maximum extension distance for each device and coaxial cable length = = 20.5 km. Therefore, the total transmission distance is 20 km. Example 3: From 001 to 004 When 6 optical bus repeaters (one pair of 4 km and two pairs of 15 km) are mounted, transmission distance depending on the number of bus repeater and optical bus repeater = 24-6 = 18 km, the sum of the maximum extension distance for each device and coaxial cable length = = 36 km. Therefore, the total transmission distance is 18 km. GS 32Q01B20-31E July 21,

7 7 Maximum number of pairs for optical bus repeater: It is possible to use four sets of 2 optical bus repeaters. The following indicates an example of optical bus repeater connection. SENG/HIS001 SENG/HIS002 HIS003 HIS FCS001 FCS002 FCS003 F05E.ai Figure Example of Optical Bus Repeater in Star Type Connection GS 32Q01B20-31E July 21,

8 8 Ethernet Ethernet is a network used for file transfer and information communication among SENG, HIS/ENG for CENTUM, and other general-purpose Ethernet instruments. Ethernet communication is usually performed via an Ethernet card mounted a PC or a server. Communication Protocol Based on IEEE802.3 ESB Bus ESB buses are I/O communication buses that connect the safety node units with the safety control unit of the. The Number of Connectable Units The maximum number of I/O nodes (SNB10D) that are connectable with the CPU node using the ESB bus is 9. Transmission Network Specifications Network topology: Bus topology Transmission channel redundancy: dual-redundant Network speed: 128 Mbits/sec. Network cable: dedicated cable (YCB301), Fiber-optic cable (*1) Maximum transmission distance: 10 m (ESB / node area), maximum 5 km (when Optical ESB Bus Repeater is used) *1: Fiber-optic Cable Specifications Connector: LC type (IEC compliant) Recommended cable: Silica-Based Single-Mode Fiber (JIS C6835 SSMA -9.3/125, IEC B1.1) Number of cores: 2 ESB Bus can be extended by using Optical ESB Bus Repeater Module (SNT401, SNT501). Several connecting combinations, including chain type and star type, are available. ESB Bus: Max.10 m ESB Bus CPU Node I/O Node I/O Node Fiber-optic Cable Max. extension distance of fiber-optic Cables I/O Node I/O Node ESB Bus I/O Node I/O Node Connect with fiber-optic Cables: 1st stage Fiber-optic Cable I/O Node I/O Node I/O Node ESB Bus: Max.10 m Connect with fiber-optic Cables: Two stage max. F03E.ai Figure Functional Overview of ESB Bus and Optical ESB Bus Repeater GS 32Q01B20-31E July 21,

9 9 SYSTEM REQUIREMENTS Hardware Requirements The Standard Operation and Monitoring Function runs on a personal computer (IBM PC/AT-compatible) which meets the following requirements: For Windows 7 CPU Core2 Duo minimum 2.13 GHz Xeon dual core minimum 2.0 GHz Main memory 4 GB Free space of minimum 20 GB Hard disc Free space of minimum 40 GB Recommended When the operation history database is stored for access control and operation history management package, free space of minimum 100 GB Display Minimum SXGA (1280 x 1024) resolution, True Color (min million colors) For wide screen Minimum WXGA+ (1440 x 900) resolution, True Color (min million colors) Graphics DirectX 9-class GPU(Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control bus interface (*1) Mouse Optical disc drive DVD-ROM *1: VF702 is required for control network interface card. For Windows Vista CPU Core2 Duo minimum 2.13 GHz Xeon dual core minimum 2.0 GHz Main memory Minimum 2 GB Free space of minimum 20 GB Hard disc Free space of minimum 40 GB Recommended When the operation history database is stored for access control and operation history management package, free space of minimum 100 GB Display Minimum SXGA (1280 x 1024) resolution, True Color (min million colors) For wide screen Minimum WXGA + (1440 x 900) resolution, True Color (min million colors) Graphics DirectX 9-class GPU (Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control bus interface (*1) Mouse Optical disc drive DVD-ROM *1: VF702 is required for control network interface card. For Windows Server 2008 R2 CPU Xeon dual core minimum 2.93 GHz Main memory 4 GB Free space of minimum 20 GB Hard disc Free space of minimum 40 GB Recommended When the operation history database is stored for access control and operation history management package, free space of minimum 100 GB Display Minimum SXGA (1280 x 1024) resolution, True Color (min million colors) For wide screen Minimum WXGA+ (1440 x 900) resolution, True Color (min million colors) Graphics DirectX 9-class GPU(Graphics Processing Unit) that supports A WDDM(Windows Driver Display Model) Driver Pixel Shader 2.0 in hardware 32 bits per pixel 128 MB Graphics memory Expansion slot 1 slot is used for control bus interface (*1) Mouse Optical disc drive DVD-ROM *1: VF702 is required for control network interface card.

10 10 For Windows Server 2008 CPU Core2 Duo minimum 2.13 GHz Xeon dual core minimum 2.0 GHz Main memory Minimum 2 GB Free space of minimum 20 GB Hard disc Free space of minimum 40 GB Recommended When the operation history database is stored for access control and operation history management package, free space of minimum 100 GB Display Minimum SXGA (1280 x 1024) resolution, True Color For wide screen Minimum WXGA + (1440 x 900) resolution, True Color Expansion slot 1 slot is used for control bus interface (*1) Mouse Optical disc drive DVD-ROM *1: VF702 is required for control network interface card. Software Requirements Release No. Windows 7 Professional Windows Vista Business Edition Windows Server 2008 Standard Edition R2 Windows Server 2008 Standard Edition Windows Server 2003 Standard Edition R2 Windows Server 2003 Standard Edition 64 bit 32 bit 64 bit 32 bit 32 bit SP1 SP2 SP1 SP2 SP2 SP2 R to R X X X X (*1) (*1) X: Compatible : Not compatible Note: Service Pack is abbreviated as SP (Example: SP1 stands for Service Pack 1). *1: The Windows Server 2003 is applicable as the file server of the project database.

11 11 CRITERIA FOR THE INSTALLATION ENVIRONMENT The table below presents the criteria for the environment where the safety control unit and the safety node unit are to be installed. For PCs, V net, bus repeaters, optical bus repeaters, and I/O modules, refer to their respective general specifications. Temperature Item Specifications Remarks Normal operation Transportation/storage 40 to 85 C 20 to 50 C (basic safety control unit) 20 to 70 C (wide range temperature safety control unit and safety node unit) 0 to 60 C when the ALR111-S01/ ALR121-S01 is mounted. 0 to 70 C when the ALR121-S0B is mounted. Humidity Temperature change Power supply Withstanding voltage Insulation resistance Normal operation 5 to 95 % RH (non-condensing) 5 to 85 % RH when the SRM53D/ Transportation/storage 5 to 95 % RH (non-condensing) SRM54D/SBM54D is mounted. During operation Transportation/storage Voltage range Frequency Distortion factor Crest factor Momentary failure DC power supply ripple rate Within ±10 C/h Within ±20 C/h 100 to 120 V AC: 15 % to +10 % 220 to 240 V AC: 15 % to +10 % 24 V DC: 10 % to +20 % 50/60 Hz ± 3 Hz 10 % or less 100 V system: 118 V or larger 220 V system: 258 V or larger 20 ms or less (when receiving the rated AC voltage) 1 % P-P maximum 1500 V AC for 1 minute (for 100 to 120/220 to 240 V AC) 20 M ohms at 500 V DC Between power & ground terminals Between power & ground terminals Grounding Independent grounding 100 ohms or less Dust Maximum of 0.3 mg/m 3 Corrosive gas Noise Vibration Impact Altitude Electric field Static electricity Continuous vibration Non-continuous vibration Seismic Transportation ANSI/ISA S71.04 G3 (standard) 10 V/m maximum (80 MHz to 1 GHz) 4 kv or less (direct discharge) 8 kv or less (aerial discharge) Amplitude: 1.75 mm (5 to 9 Hz) Acceleration: 4.9 m/s 2 (9 to 150 Hz) Amplitude: 3.5 mm (5 to 9 Hz) Acceleration: 9.8 m/s 2 (9 to 150 Hz) Acceleration: 4.9 m/s 2 or less Horizontal: 4.9 m/s 2 or less Vertical: 9.8 m/s 2 or less 147 m/s 2, 11 ms 2000 m above sea level or less Excluding SRM53D/SRM54D/ SBM54D When packaged

12 12 APPLICABLE STANDARDS The hardware components of the comply with the standards below. PLC Standard IEC (*1, *2, *3) Functional Safety Standard IEC Application Standards (*1) EN 54 (*4), EN 298 (*3, *5), EN , IEC , IEC 62061, NFPA85, NFPA72 Safety Standards (*6, *13) [CSA] CSA C22.2 No ( V AC power supply specification) [CE Marking] Low Voltage Directive EN ( V AC (*12), V AC and 24 V DC power supply specifications) (*7) EMC Conformity Standards (*1, *2, *6) [CE Marking] EMC Directive EN Class A Group 1 equivalent ( V AC (*12), V AC and 24 V DC power supply specifications) (*8) EN ( V AC (*12), V AC and 24 V DC power supply specifications) (*1) EN ( V AC power supply specification) (*9) EN ( V AC power supply specification) [C-Tick Marking] EN Class A Group 1 ( V AC and 24 V DC power supply specifications) [KC Marking] ( V AC (*12), V AC and 24 V DC power supply specifications) Korea Electromagnetic Conformity Standard Standards for Hazardous Location Equipment (*10) [FM Non-Incendive] Class I, Division 2, Groups A, B, C and D, Temperature Code T4 FM Standard Class Number 3600: 1998 FM Standard Class Number 3611: 2004 FM Standard Class Number 3810: 2005 For V AC, V AC and 24 V DC power supply [Type n ] (*11) II 3G Ex nc[nl] II C T4 Gc EN : 2005 EN : 2009 For 24 V DC power supply Marine Standards (*10) ABS (American Bureau of Shipping) BV (Bureau Veritas) Lloyd s Register Note: According to the New Approach Directive, the manufacturer and the representative office in EU are indicated below: Manufacturer: YOKOGAWA Electric Corporation ( Nakacho, Musashino-shi, Tokyo , Japan.) Representative office in EU Community: Yokogawa Europe B.V. (Euroweg 2, 3825 HD Amersfoort, The Netherlands.) *1: For surge immunity, an external device, such as a lightning arrester, is needed. *2: The 24 V DC and 48 V DC power supply lines from the field power supply to DI and DO needs to be 30 m or less. *3: When 24 V DC (SPW484) is used for the system power supply, a UPS should be attached externally. *4: The clamp filter (A1193MN) needs to be added to the V net cable. *5: The 24 V DC and 48 V DC power supply lines from the field power supply to DI and DO needs to be 10 m or less. *6: For a rack-mounted device to comply with safety standards and EMC standards, it needs to be housed in a lockable metal cabinet. *7: The analog inputs of this system fall into Measurement Category I of IEC For details, refer to the Installation Guidance (TI 32S01J10-01E). *8: A Class A hardware device is designed for use in the industrial environment. Please use this device in the industrial environment only. *9: To restrain the power supply s harmonic waves, a power supply device with harmonic wave restraining capability or an external device with such a capability (e.g. active filter) needs to be connected. *10: See the List of Application Standard. *11: To be compatible with Type n, for example the requirements of cabinet must be met. For details, refer to the Explosion Protection (TI 32S01J30-01E). *12: SSC does not comply with CE Marking and KC Marking requirements of 100 V AC. *13: For ensuring all the hardware devices to satisfy the safety standards, the dedicated breakers in the power supply distribution board must conform to the following specifications. [CSA] CSA C22.2 No.5 or UL 489 [CE Marking] EN and EN

13 13 Models Standards for Hazardous Location Equipment (*1) FM Non- Incendive Type n Table List of Applicable Standard (1/2) Marine Standards (*2) ABS (American Bureau of Shipping) BV (Bureau Veritas) Lloydś Register remarks SSC10D X X X X X Including SCP401, SPW481, SPW482, SPW484 SSC10S X X X X X Including SCP401, SPW481, SPW482, SPW484 SNB10D X X X X X Including SPW481, SPW482, SPW484, SSB401 SAI143 X X X X X Including SCCC01, STA4D, STA4S, STK4A Style code S3 does not comply with Marine Standards. SAV144 X X X X X Including SCCC01, STA4D, STA4S, STK4A SAT145 X X X X X SAR145 X X X X X SAI533 X X X X X Including SCCC01, STA4D, STA4S, STK4A SDV144 X X X X X Including SCCC01, SCCC02, STB4D, STB4S, STD4A SDV144-S C does not comply with Marine Standards. SDV521 X X X X X SDV521-S3C does not comply with Marine Standards. SDV526 SDV531 X X X X X SDV53A X X X X X SDV541 X X X X X SCB100 X X X X X SCB110 X X X X X Including SCCC01, SCCC02, STB4D, STB4S, STD4A SDV531-L complies with Marine Standards from style code S3. SDV531-L C does not comply with Marine Standards. Including SCCC01, SCCC02, STB4D, STB4S, STD4A SDV541-S C does not comply with Marine Standards. SNT10D X X X X X Including SPW481, SPW482, SPW484 SNT401 X X X X X SNT501 X X X X X SEC401 X X X X X ALR111 X X X X X ALR121 X X X X X ALR121-S0B does not comply with Marine Standards. SDCV01 X X X X X SEA4D X X X X X SED2D X X X X X SED3D X X X X X SED4D X X X X X SWD2D SBT4D X X X X X SBR4D X X X X X SBA4D X X X X X SBD2D X X X X X X: Certified : Non-Certified *1: For details, refer to Explosion Protection (for ) (TI 32S01J30-01E). *2: For details, refer to Installation Guidance (TI 32S01B10-01E).

14 14 Table List of Applicable Standard (2/2) Models Standards for Hazardous Location Equipment (*1) FM Non- Incendive Type n Marine Standards (*2) ABS (American Bureau of Shipping) BV (Bureau Veritas) Lloydś Register SBD3D X X X X X SBD4D X X X X X SRM53D X X X SRM54D X X X SBM54D X X X VF702 X X X VF701 X X X YCB301 X X X X X YCB141 X X X X X YCB111 X X X AKB651 X X X X X AKB331 X X X X X AKB136 X X X X X AKB161 X X X X X AKB611 X X X X X KS1 X X X X X YCB148 X X X X X YCB146 X X X YCB128 X X X X X remarks X: Certified : Non-Certified *1: For details, refer to Explosion Protection (for ) (TI 32S01J30-01E). *2: For details, refer to Installation Guidance (TI 32S01B10-01E). TRADEMARKS CENTUM and ProSafe are registered trademarks of Yokogawa Electric Corporation. Windows and Windows Vista are registered trademarks of Microsoft Corporation in the USA and other countries. Ethernet is a registered trademark of XEROX Corporation, USA. Modbus is a registered trademark of Schneider Electric SA. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice.

General Specifications

General Specifications General Specifications GS 32Q01B30-31E ProSafe-RS Safety Instrumented System Overview (for Vnet/IP-Upstream) GENERAL The ProSafe-RS is a Safety Instrumented System that is certified by the German certification

More information

General Specifications

General Specifications General Specifications GS 32Q01B10-31E ProSafe-RS Safety Instrumented System Overview (for Vnet/IP) GENERAL The ProSafe-RS is a Safety Instrumented System that is certified by the German certification

More information

General Specifications

General Specifications General Specifications Safety Instrumented System GS32S01B10-01E GENERAL This GS explains the components and system specifi cations of the system. The is a Safety Instrumented System that is certifi ed

More information

General Specifications

General Specifications General Specifications GS 32Q01B30-31E ProSafe-RS Safety Instrumented System Overview (for Vnet/IP-Upstream) GENERAL The ProSafe-RS is a Safety Instrumented System that is certified by the German certification

More information

General Specifications

General Specifications General Specifications ProSafe-RS Standards Compliant s GS 32P01B60-01EN GENERAL The hardware components of the ProSafe-RS comply with the standards below. Functional Safety Standards IEC 61508, IEC 61511-1,

More information

General Specifications

General Specifications General Specifications GS 32P01B30-01EN ProSafe-RS Safety Instrumented System Overview (for Vnet/IP-Upstream) GENERAL The ProSafe-RS is a safety instrumented system certified by TÜV Rheinland, a German

More information

General Specifications

General Specifications General Specifications GS 32P06K60-01EN ProSafe-RS Outline of I/O Modules (for FIO) GENERAL This GS provides the specifications of I/O modules to be mounted on the safety control unit or the safety node

More information

General Specifications

General Specifications General Specifications GS 32Q06L20-31E Terminal Boards/ Relay Boards (for ProSafe-RS) GENERAL This GS describes the hardware specifications of the terminal boards used for the ProSafe-RS system. STANDARD

More information

General Specifications

General Specifications General Specifications GS 33S01B10-31E Production Control System CENTUM CS 1000 System Overview R3 GENERAL This GS covers the system specifications, components and network specifications of the CENTUM

More information

General Specifications

General Specifications General Specifications GS 32Q06D20-31E Models SSC50S, SSC50D Safety Control Unit, Duplexed Safety Control Unit (for Vnet/IP, Rack Mountable Type) GENERAL This GS provides the hardware specifications of

More information

General Specifications

General Specifications General Specifications Models ALR111, ALR121 Serial Communication Modules GS 32Q06K50-31E GENERAL This document describes about Models ALR111 and ALR121 Serial Communication Modules used with a safety

More information

General Specifications

General Specifications General Specifications GS 32P01B10-01EN ProSafe-RS Safety Instrumented System Overview (for Vnet/IP) GENERAL ProSafe-RS is a safety instrumented system, to meet safety integrity level 3 (SIL3) specified

More information

General Specifications

General Specifications General Specifications GS 33K30D10-50E Model LPC6900, LPC6910, LPC6920, LPC6930 SEM Sequence of Events Manager (for Vnet/IP and FIO) GENERAL This GS (General Specifications) describes the specifications

More information

General Specifications

General Specifications General Specifications Model LHS5100, LHM5100 Standard Builder Function GENERAL The standard builder function package is used for configuring the system of. It creates database necessary for implementing

More information

General Specifications

General Specifications General Specifications Model VP6P6900, VP6P6910, VP6P6920, VP6P6930 SEM Sequence of Events Manager GS 33J30D10-01EN [Release 6] GENERAL This GS (General Specifications) describes the specifications of

More information

General Specifications

General Specifications General Specifications Digital I/O Modules (for FIO) GS 32Q06K40-31E GENERAL This GS provides the hardware specifications of the digital I/O modules that can be installed in the Safety Node Unit and Safety

More information

General Specifications

General Specifications General Specifications Model VP6P6900, VP6P6910, VP6P6920, VP6P6930 SEM Sequence of Events Manager GS 33J30D10-01EN [Release 6] GENERAL This GS (General Specifications) describes the specifications of

More information

General Specifications

General Specifications General Specifications Model VP6P6900, VP6P6910, VP6P6920, VP6P6930 SEM Sequence of Events Manager [Release 6] GENERAL This GS (General Specifications) describes the specifications of the Sequence of Events

More information

General Specifications

General Specifications General Specifications Model VP6P6900, VP6P6910, VP6P6920, VP6P6930 SEM Sequence of Events Manager GS 33J30D10-01EN [Release 6] GENERAL This GS (General Specifications) describes the specifications of

More information

General Specifications

General Specifications General Specifications Automation Design Suite (AD Suite) VP6E5000 Engineering Server Function VP6E5100 Standard Engineering Function GENERAL Automation Design Suite (AD Suite) provides an engineering

More information

General Specifications

General Specifications TM1 READY FUSE RL1 CN1 (PSU-L) TM2 100-120V AC CN2 (PSU-R) General Specifications N-IO System Overview GENERAL The N-IO system is connected to the Field Control Unit (A2FV50 ) via

More information

General Specifications

General Specifications General Specifications Turbomachinery Controller Overview GS 34P02Q04-01E OVERVIEW The General Specifications (GS) describe the features, functions, system configuration examples, engineering environment,

More information

General Specifications

General Specifications General Specifications GS 32P06K51-01EN Model ALE111 Ethernet Communication Module GENERAL This document describes about Model ALE111 Ethernet communication module used with a safety control station ()

More information

General Specifications

General Specifications General Specifications GS 33Q01B10-31E Integrated Production Control System CENTUM System Overview R3 GENERAL This GS covers the system, component and network specifications of the CENTUM integrated production

More information

General Specifications

General Specifications General Specifications Integrated Production Control System System Overview (Vnet/IP Edition) GENERAL This document describes about Production Control System (for Vnet/IP) which controls and monitors industrial

More information

General Specifications

General Specifications General Specifications GS 32P06P10-01EN Models S2BN4D, S2BN5D Base Plates for Barrier (for N-IO) System Models: S2ZN4D, S2ZN5D N-IO I/O Unit GENERAL This General Specifications (GS) provides the specifications

More information

General Specifications

General Specifications General Specifications Cables GS 32Q06M10-31E GENERAL This GS provides the specifications for cables used in the ProSafe-RS system. DIMENSIONS Cables YCB301 ESB Bus Cable 23.8 23.8 37.61 43.5 (2) 39 (41)

More information

General Specifications

General Specifications TM1 READY FUSE RL1 CN1 (PSU-L) TM2 100-120V AC CN2 (PSU-R) General Specifications N-IO System Overview GS 33J62A10-01EN GENERAL The N-IO system is connected to the field control

More information

Technical Information

Technical Information Technical Information Vnet/IP Network Construction Guide Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 TI30A10A05-01E Copyright

More information

General Specifications

General Specifications General Specifications Models AFV10S, AFV10D Field Control Unit Duplexed Field Control Unit (for Vnet/IP, for FIO, 19" Rack Mountable Type) R3 GENERAL This GS covers the hardware specifications of the

More information

General Specifications

General Specifications General Specifications LN90 Interface Adapter GENERAL This General Specification (GS) describes the specification for Interface Adapter. This product is a RS-485 signal relay and power supply for the Field

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

General Specifications

General Specifications General Specifications Models AFF50S, AFF50D Field Control Unit Duplexed Field Control Unit (for FIO, 19" Rack Mountable Type) R3 GENERAL This GS covers the hardware specifications of the Field Control

More information

General Specifications

General Specifications General Specifications Cables (for ProSafe-RS) GENERAL This GS covers the specifi cations for cables used in the ProSafe-RS system. DIMENSIONS Cables YCB301 ESB bus cable 23.8 23.8 37.61 43.5 (2) 39 (41)

More information

General Specifications

General Specifications General Specifications Model Communication Module (for N-IO/FIO) [Release 6] GENERAL This document describes about Model Communication Module (for N-IO/FIO) which performs as the master device (referred

More information

General Specifications

General Specifications General Specifications GS 33K20S10-50E Model SSS7100 Device OPC Server GENERAL This document describes about Model SSS7100 OPC Server which provides data of field wireless gateway to the OPC client via

More information

General Specifications

General Specifications General Specifications GS 33J64E10-01EN Models A2FV70S/A2FV70D Field Control Unit, Model A2CUKT3 Cabinet Utility Kit (For RIO System Upgrade) This document describes the hardware specifications of A2FV70S/A2FV70D

More information

General Specifications

General Specifications General Specifications Cables GENERAL This GS covers the specifications for cables used in the ProSafe-RS system. DIMENSIONS Cables YCB301 ESB bus cable 23.8 23.8 37.61 43.5 (2) 39 (41) L = 0.2 m, 1 m,

More information

General Specifications

General Specifications GR0001 Distillation column 100 100 Column flow AUT NR PV SV M3/H 70.0 M3/H 50.0 MV % 65.0 100.0 80.0 60.0 40.0 20.0 0.0 TDA 37.5 41.4 TDT 53.8 RC-10 23.4 % 38.9 TRC 49.2 LICA 25.4 % 51.3 PAC LICA 45.7

More information

General Specifications

General Specifications General Specifications GS 34P02Q04-02E Turbomachinery Controller Overview (FCN-500/FCN-RTU) OVERVIEW The General Specifications (GS) describe the features, functions, system configuration examples, engineering

More information

General Specifications

General Specifications General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial

More information

General Specifications

General Specifications General Specifications YFGW710 Field Wireless Integrated Gateway GENERAL This General Specification (GS) describes the hardware specifications for Field Wireless Integrated Gateway and specifications of

More information

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system

CO General Specifications GS48D62Z00-00E-N GENERAL. ProSafe-COM extended communication system General Specifications GS48D62Z00-00E-N CO-962-00 ProSafe-COM extended communication system GENERAL Figure 1 ProSafe-COM extended communication system is a multiple protocol communication interface connecting

More information

General Specifications

General Specifications General Specifications AEP7D Primary Power Supply Bus Unit GEERA This hardware GS covers the AEP7D Primary Power Supply Bus Unit which distributes power to equipment mounted in the same cabinet. The AEP7D

More information

General Specifications

General Specifications General Specifications System Overview Outline This General Specifi cations (GS) describes features of a fi eld wireless system, system confi guration a fi eld wireless network, system confi guration devices,

More information

General Specifications

General Specifications General Specifications GS 33J60G20-01EN Model ALF111 Foundation TM fieldbus Communication Module (for N-IO/FIO) [Release 6] GENERAL This document describes about Model ALF111 Foundation fieldbus Communication

More information

General Specifications

General Specifications General Specifications Model LHS1100, LHM1101 Standard Operation and Monitoring Function GENERAL Standard Operation and Monitoring Function has various functions required to monitor plant operation. A

More information

Technical Information

Technical Information Technical Information CENTUM CS 3000 Installation Guidance Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright May 1998

More information

General Specifications

General Specifications General Specifications GS 33K05K20-50E Models LHS5450, LHS4450 Multiple Project Connection Package GENERAL manages Field Control Station (FCS) and Human Interface Station (HIS) engineering data created

More information

CENTUM VP Release 5.01 Integrated Production Control System Order Entry Starts

CENTUM VP Release 5.01 Integrated Production Control System Order Entry Starts Sales News CENTUM VP Release 5.01 Integrated Production Control System Order Entry Starts NO: SPMK11E-135 DATE: August 19, 2011 Yokogawa has released CENTUM VP Release 5.01 (R5.01) integrated production

More information

General Specifications

General Specifications General Specifications GS 36J02A10-01E NTPF100 OPC Interface Package GENERAL As data sharing between information systems increases, the requirement to efficiently access and use plant information to meet

More information

General Specifications

General Specifications General Specifications GS 30B05A21-01EN PM4S7740 PRM Advanced Diagnosis Server GENERAL PRM advanced diagnostic function is an optional feature of plant resource manager (PRM) package. It diagnoses plant

More information

General Specifications

General Specifications General Specifications Model VP6H1100 Standard Operation and Monitoring Function GENERAL Standard Operation and Monitoring Function has various functions required to monitor plant operation. A variety

More information

General Specifications

General Specifications General Specifications Model AW810D Communication Router GENERAL Communication Router () is the hardware equipment to connect domains via (WAN). Operations and monitoring of the /SCS that are distributed

More information

General Specifications

General Specifications General Specifications Model VP6F1250 Generic Subsystem Gateway Package [Release 6] GENERAL is an operation and monitoring station for subsystems that are pre-process and post-process pieces of equipment

More information

General Specifications

General Specifications General pecifications YFGW410 Field Wireless Management tation G 01W02D01-01EN GENERAL This General pecification(g) describes the hardware specifications for Field Wireless Management tation and specifications

More information

General Specifications

General Specifications General Specifications GS 33J10D60-01EN Models VP6E5425, VP6E5426, VP6E5427 Expanded Test Functions Simulator Package Simulator Package [Release 6] GENERAL This document describes about specifications

More information

General Specifications

General Specifications General Specifications Integrated Production Control System CENTUM VP System Overview [Release 6] GENERAL CENTUM VP is an integrated production control system for controlling plants that is used in a wide

More information

General Specifications

General Specifications General Specifications GS 36J02A10-01E Model NTPF100 OPC Interface Package GENERAL As data sharing between information systems increases, the requirement to efficiently access and use plant information

More information

General Specifications

General Specifications General Specifications Models PW601, PW602 24 V DC Output Power Supplies Model AEP9D Secondary Power Supply Bus Unit [Release 6] GENERAL This GS covers the hardware specifications of the 24 V DC Output

More information

General Specifications

General Specifications General Specifications GS 32P06Q10-01EN Models S2NN70D, S2NN60D, S2CB60 N-IO field enclosure (System Models: S2ZN70D, S2ZN60D) GENERAL This General Specifications (GS) covers the hardware specifications

More information

General Specifications

General Specifications General Specifications GS 33J01A10-01EN Integrated Production Control System CENTUM VP System Overview [Release 6] GENERAL CENTUM VP is an integrated production control system for controlling plants that

More information

General Specifications

General Specifications General Specifications Cables R3 GENERAL This General Specification (GS) covers the specifications of cables, signal cables and communication cables used in the buses (V net, RIO bus, and VL net) which

More information

SCS (System Core Server) Model BCY44100M

SCS (System Core Server) Model BCY44100M Specifications General SCS (System Core Server) is a controller that integrates DDC (direct digital controller) and RS (remote station), such as PARAMATRIX -III and Infilex series controllers, into BMS

More information

Communication Devices

Communication Devices User's Manual Communication Devices 4th Edition Introduction i The optical bus repeater and the bus repeater are used to extend the transmission distance of V net. This manual describes the communication

More information

TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN Characteristics controller M251 Ethernet CAN Price* : 278.88 GBP Main Range of product Product or component type [Us] rated supply voltage Complementary Number of I/O expansion module Supply voltage limits

More information

General Specifications

General Specifications General Specifications Terminal Boards (for FIO) GS 33K50H51-50E [Release 5] GENERA This document describes the specifications of terminal boards with DIN rail type used for FIOs of CENTUM VP systems.

More information

General Specifications

General Specifications General Specifications GS 33K05D10-50E Model LHS1100, LHM1101 Standard Operation and Monitoring Function Model LHS1120 Console HIS Support Package for Enclosed Display Style Model LHS1130 Console HIS Support

More information

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module Product datasheet Characteristics TM251MESE Main Range of product Product or component type [Us] rated supply voltage Modicon M251 Logic controller 24 V DC Complementary Number of I/O expansion module

More information

General Specifications

General Specifications General Specifications GS 32Q03B20-31E Model CFS1100 Safety Control Functions Package GENERAL Safety Control Functions Package is a software package that monitors a plant to ensure it is operating safely.

More information

Communications & Networking

Communications & Networking is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

General Specifications

General Specifications General Specifications FCN Autonomous Controller Functions (FCN-500) GENERAL This document describes the system configurations, development/maintenance, software configurations, and network specifications

More information

General Specifications

General Specifications General Specifications GS 33K50G11-50E Model ALE111 Ethernet Communication Module (for FIO) GENERAL This document describes about Model ALE111 Ethernet Communication Module (for FIO) that a field control

More information

TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN Characteristics controller M251 Ethernet CAN Product availability : Stock - Normally stocked in distribution facility Price* : 519.00 USD Main Range of product Product or component type [Us] rated supply

More information

General Specifications

General Specifications General Specifications System Overview Outline This General Specifications (GS) describes features of a field wireless system, system configuration a field wireless network, system configuration devices,

More information

General Specifications

General Specifications General Specifications GS 33Y05P10-33E Models SSS5700, SSS6700 Fieldbus Communication Functions (R5) GENERAL With the Fieldbus Communication Function, a field control station () can be connected via the

More information

General Specifications

General Specifications General Specifications Model NTPA400 Exatas Package Terminal Automation Overview GENERAL A terminal/large depot (hereinafter referred to as a terminal) is a storage area where petroleum products are received

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

General Specifications

General Specifications General Model A2MMM843, A2MDV843 I/O Modules (for N-IO) GS 33J62F20-01EN GENERAL This general specifications (GS) contains hardware specifications of I/O modules (for N-IO) that can be mounted on the base

More information

General Specifications

General Specifications General pecifications YFGW410 Field Wireless Management tation G 01W02D01-01EN GENERAL This General pecification(g) describes the hardware specifications for Field Wireless Management tation and specifications

More information

General Specifications

General Specifications General Specifications GS 33J60G11-01EN Model ALE111 Ethernet Communication Module (for N-IO/FIO) [Release 6] GENERAL This document describes about Model ALE111 Ethernet Communication Module (for N-IO/FIO)

More information

NE1A/DST1. DeviceNet Safety System

NE1A/DST1. DeviceNet Safety System System Omron now offers a DeviceNet compatible Safety System, that can be used 3-ways: as a Standalone controller, as a Safety network expandable with remote I/O blocks, or combined with DeviceNet to form

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

Technical Information

Technical Information Technical Information Virtualization Platform Planning and Implementation Guide TI 30A05B10-01EN Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan TI 30A05B10-01EN Copyright

More information

General Specifications

General Specifications General Specifications Models VP6E5450, VP6H4450 Multiple Connection Package GENERAL manages Field Control Station (FCS) and Human Interface Station (HIS) engineering data created in System Generation

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage

More information

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet Characteristics controller M241 40 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage 18 Nov, 2018 Modicon M241 Logic controller 24 V DC Discrete input

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

General Specifications

General Specifications General Specifications GS 33J05D10-01EN Model VP6H1100 Standard Operation and Monitoring Function GENERAL Standard Operation and Monitoring Function has various functions required to monitor plant operation.

More information

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Characteristics Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Complementary Supply [Us] rated supply voltage Immunity to microbreaks

More information

MindConnect Nano Product Sheet

MindConnect Nano Product Sheet MindConnect Nano Product Sheet MindConnect Nano is a device for transferring data and allows connectivity to MindSphere. Different protocols are supported in order to collect data. The device supports

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM241CE24T controller M241 24 IO transistor PNP Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current

More information

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity PRODUCT OVERVIEW ` CVM1 Series The CVM1D Duplex system s redundancy is a new option in Omron s large controllers. Two redundant CPUs and power supplies ensure that processes will continue operation when

More information

General Specifications

General Specifications General Specifications Analyzer Bus System GS 11B06A02-01E GENERAL Process analyzers have been typically maintained by maintenance personnel from the front of the analyzer. However, with the implementation

More information

TM241C40U controller M IO transistor NPN

TM241C40U controller M IO transistor NPN Characteristics controller M241 40 IO transistor NPN Main Range of product Product or component type [Us] rated supply voltage 15/12/2018 Modicon M241 Logic controller 24 V DC Discrete input number 24

More information

TM3TI8T module TM3-8 inputs temperature

TM3TI8T module TM3-8 inputs temperature Characteristics module TM3-8 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 8 Analogue input type Complementary Analogue input resolution Input

More information

TM241C24T controller M IO transistor PNP

TM241C24T controller M IO transistor PNP Characteristics controller M241 24 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Feb 13, 2018 Modicon M241 Logic controller 24 V DC Discrete input number 14

More information

General Specifications

General Specifications General Specifications GS 33J62F40-01EN Models A2BN3D, A2BN4D, A2BN5D Base Plates (for N-IO) System Models: A2ZN3D, A2ZN4DC, A2ZN5DC N-IO I/O Unit GENERAL This General Specifications (GS) covers the specifications

More information