2016 ROTRONIC AG Bassersdorf Switzerland RMS CONVERTER

Size: px
Start display at page:

Download "2016 ROTRONIC AG Bassersdorf Switzerland RMS CONVERTER"

Transcription

1 2016 ROTRONIC AG Bassersdorf Switzerland RMS CONVERTER

2 Table of Contents 1 Overview RMS system overview RMS Converter Power Supply Interface Device dimension Installation Default configuration Configuration via web interface Configuration via RMS CONFIG Software Integration of the RMS Converter (Pairing) into the RMS WEB Software Add devices via RMS Converter Firmware-Update RMS-Converter Firmware Update via RMS Software Firmware Update per RMS-CONFIG Tool Technical Specification Further documents Document Version ROTRONIC AG Bassersdorf Switzerland Page 2 of 39

3 Scope: This manaul is related to the RMS-Converter Firmware Version V1.2. The small digit represents small changes, bug fixes etc. that do not influence main functions of the device. 1 Overview 1.1 RMS system overview The Rotronic Monitoring System RMS is a network of various devices and RMS server software. The software represents the core piece of the whole RMS. It collects measuring and system data of the devices and stores it into the database. The single devices work as input modules (datalogger) and output moduls (displays, analog outputs, switching outputs. The user can monitor this measuring- and system data by PC, laptop or smart mobiles everywhere and every time. Figure 1: Schematic diagram of the RMS 2016 ROTRONIC AG Bassersdorf Switzerland Page 3 of 39

4 1.2 RMS Converter The aim of the RMS Converter is to provide a simple integration of Rotronic devices and networks of earlier generation into the RMS. The RMS Converter acts as a adaptation between these devices an the RMS - by translation of the propriatary device protocolls to the RMS and back. By this way, measuring- and system are exchanged between devices and RMS. In case of communication interruption between RMS Converter and server software, the converter loggs the collected data into the internal memory (for max. 1 week). As far as the connection is completed again, the data will be synchronized between converter and server. In this manner data loss will be avoided. Beside the Rotronic device integration, the RMS Converter provides the following main function: o Direct integration of digital OEM devices into the RMS o Upgradeable for custom-built software- or device function o FW Update 1.3 Power Supply The RMS Converter is power supplied by a switching power supply 5VDC. It is part of the supplied package. 1.4 Interface The communication of the RMS Converter run via LAN and needs no further interface or plug ROTRONIC AG Bassersdorf Switzerland Page 4 of 39

5 2 Device dimension Figure 2: Device dimension 2016 ROTRONIC AG Bassersdorf Switzerland Page 5 of 39

6 3 Installation To install the RMS Converter, it is necessary to connect the LAN port to the ethernet network and energize it with the power supply. 3.1 Default configuration The RMS Converter is default configured with DHCP active. That means that the RMS Converter gets the IP-address from the DHCP-Server automatically. Fix IP address can be set by a manual configuration via the web browser or via the RMS CONFIG Software see following chapter. 3.2 Configuration via web interface To configure the RMS Converter please type into the address bar of the web browser. Instead of "XXXXXXXX" please use the serial number (see the bottom side of the RMS Converter) Figure 3: Configuration of the RMS Converter via web interface As far as the RMS Converter is configured with a fix IP address, the device can be accessed typing into the web browser (in the expample of Fig. 3 -> ROTRONIC AG Bassersdorf Switzerland Page 6 of 39

7 3.3 Configuration via RMS CONFIG Software The RMS Converter can also be configured by the RMS CONFIG Software. The RMS CONFIG is a configuration software tool that can be downloaded at For configuration please follow the figures below. Figure 4: Search for network devices Figure 5: Choose the RMS Converter 2016 ROTRONIC AG Bassersdorf Switzerland Page 7 of 39

8 After clicking <Add> it appears the following window: Figure 6: Settings of the RMS Converter Modus Figure 7: Modus - for the use of the Rotronic Cloud Server 2016 ROTRONIC AG Bassersdorf Switzerland Page 8 of 39

9 Figure 8: Modus - for the use of a local server In case of local server, the IP address or link of the local server must be entered at IP. Settings Figure 9: Service path In case of local server the WebService path must be adapted to the local settings of the local server. See user manual E-IM-RMS-WEB If the configuration is finished, the RMS Converter can be integrated into the RMS server software for further information please see the manual E-SM-RMS-WEB. For a successful integration of the RMS Converter into the RMS System, the port 80 of the network must be opened. The RMS Converter must be able to send data to the RMS server (local or cloud) Case of DHCP active: A DHCP server must supply an IP address automatically. Case of Fix IP: If no DHCP server is used, a fixed IP address can be set for the RMS Converter by the network administrator manually ROTRONIC AG Bassersdorf Switzerland Page 9 of 39

10 3.4 Integration of the RMS Converter (Pairing) into the RMS WEB Software Integration of a RMS Converter into RMS (Paring) in 7 steps as follows: Login into the RMS Software -> Tools -> Setup -> Devices -> New -> LAN device 1 Figure 10: Add new LAN device Type the serial number of the RMS Converter and click <OK> 3 Figure 11: Enter the serial number Click the link 4 Figure 12: Click the link 2016 ROTRONIC AG Bassersdorf Switzerland Page 10 of 39

11 Click <Pair> and change back to the browser tab Devices RMS Setup 5 Figure 13: Click Pair Configure the device further (device name, intervall, group) 6 Figure 14: Further configuration The configuration / integration of the RMS Converter is finished. 7 Figure 15: Finish of the integration For details of the RMS server software please see the user manual E-SM-RMS-WEB 2016 ROTRONIC AG Bassersdorf Switzerland Page 11 of 39

12 3.5 Add devices via RMS Converter Please click Tools -> Setup Please click the RMS Converter within the device list -> Devices -> Add/Search Figure 16: Dialog window after device search Select your device to implement Figure 17: List of selectable devices 2016 ROTRONIC AG Bassersdorf Switzerland Page 12 of 39

13 The RMS Converter is able to integrate the following devices into the RMS System: Rotronic devices (earlier generation): This devices group contains HF4, HF5, HF6, HF8, HLNT, PF4/5, CRP5, HL-RC (GP FlexGate2 433MHz, GP FlexGate2 US 915MHz) AF1 (RS485) via AC3011 Masterbox BF2 (RS485) via AC3011 Masterbox 3rd party devices: This devices group contains Airy P231 Particle counter Lighthouse ApexR5 Particle counter RMS-8ADC-L-R-A The RMS Converter integrates these devices based on existing networks as ethernet, RS485 and RF Add HF4, HF5, HF6, HF8 Network configuration of the device To add one of these devices into the RMS, it is necessary to discover the individual network configuration of the device as DHCP active / not active (fix IP address) Host name To find and configure the network settings of the device, please connect the device into the LAN and use the Digi Device Discovery Tool. (Download: ROTRONIC AG Bassersdorf Switzerland Page 13 of 39

14 Open and execute DigiDeviceDiscovery.exe -> Device search starts automatically. Figure 18: Digi Device Discovery Tool - device list Double click on the device and login -> a web browser opens (default username: rotronic / default password: wlan) Figure 19: Login Digi Modul Check/change DHCP, Hostname, IP address For further information see the short manual of the Digi Device Discovery tool 2016 ROTRONIC AG Bassersdorf Switzerland Page 14 of 39

15 Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices Select AirChip3000 (See following figure) and click Search Device Figure 20: Device search AirChip family It is possible to type the IP address or host name into the field IP address. It makes the search a bit faster. It appears the device (device name, serial number, IP address) and it's settings 2016 ROTRONIC AG Bassersdorf Switzerland Page 15 of 39

16 Please configure now the device (name, measurement probes, input/output/relais settings etc. see the following figure for HF8 exemplarily). Figure 21: RMS device settings of a HF8 via RMS Converter The device is added now - see following figure Figure 22: Confirmation of the added device 2016 ROTRONIC AG Bassersdorf Switzerland Page 16 of 39

17 3.5.2 Add CRP5 Network configuration of the device CRP5 is only available with fix IP address. Before you add it into the RMS web software, it is necessary to check/change the fixed device IP address. That is possible using the device keys and display or using a service cable (AC3006) and the HW4 SW. Add into the RMS Web Software Same procedure as for HF4, 5, 6, 8 (chapter before) Add PF4/5 Network configuration of the device The device is configurable with DHCP (default) or fix IP address. Please check/change the setup using the device keys and display. For the device version without keys/display but with ethernet plug, a service cable (AC3006) and the HW4 SW is necessary to check/change the device network settings. Add into the RMS Web Software Same procedure as for HF4, 5, 6, 8 (chapter before) 2016 ROTRONIC AG Bassersdorf Switzerland Page 17 of 39

18 3.5.4 Add HL-NT (HygroLogNT) Network configuration of the device Same procedure as for HF4, 5, 6, 8 Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices Select AirChip3000 (See following figure) and click Search Device Figure 23: Select HL-NT 2016 ROTRONIC AG Bassersdorf Switzerland Page 18 of 39

19 Please configure now the device (name, measurement probes, input/output/relais settings etc. see the following figure). Figure 24: RMS device settings of a HL-NT via RMS Converter 2016 ROTRONIC AG Bassersdorf Switzerland Page 19 of 39

20 3.5.5 Add HL-RC (GP FlexGate2 433 and 915 MHz RF) Network configuration of the device To setup the ethernet configuration please Open the HW4 SW Search for master devices -> Search for wireless logger -> Adapters -> Search Set DHCP or fix IP addresses etc. Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices Select HL-RC (See following figure) and click Search Device Figure 25: Select HL-RC Follow the same procedure as for the device above to configure the device properties (name, measurement probes etc.) 2016 ROTRONIC AG Bassersdorf Switzerland Page 20 of 39

21 3.5.6 Add RMS-8ADC-L-R-A Network configuration RMS-8ADC-L-R-A is a device using only a fix IP address. Remark: For the first configuration or for a reset of the default settings of the device, please Setup a point to point ethernet connection between the RMS-8ADC-L-R-A and a PC using a ethernet cable. Change the IP settings of the PC (network adapter settings IP4 ) as follows Figure 26: Fix IP address of the PC Press the button for app. 10seconds until the LED blinks short. Open a web browser and type (the default IP address is ) 2016 ROTRONIC AG Bassersdorf Switzerland Page 21 of 39

22 Login (Default username: Fact_user default password: Fact_pwd) Figure 27: Login Choose the language Figure 28: Language settings 2016 ROTRONIC AG Bassersdorf Switzerland Page 22 of 39

23 Network settings and system configuration: Figure 29: Main menu - networt settings Figure 30: Network settings 2016 ROTRONIC AG Bassersdorf Switzerland Page 23 of 39

24 Figure 31: Main menu - system configuration Figure 32: System configuration 2016 ROTRONIC AG Bassersdorf Switzerland Page 24 of 39

25 Configuration of the analog input 0-7 Figure 33: Main menu - analog inputs Figure 34: Setting and scaling of the analog inputs 2016 ROTRONIC AG Bassersdorf Switzerland Page 25 of 39

26 Add into the RMS Web Software After the finish of the network configuration, please plug the device via ethernet cable into the RMS network Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices Select RMS-8ADC-L-R-A Type the IP address of the device and click Search Device Figure 35: Select RMS-8ADC-L-R-A Please configure now the device (name, inputs etc. see the following figure). Figure 36: RMS device settings of a RMS-8ADC-L-R-A 2016 ROTRONIC AG Bassersdorf Switzerland Page 26 of 39

27 3.5.7 Add Lighthouse ApexR5 Particle counter The Lighthouse ApexR5 Particle counter is a device with an ethernet interface. Network configuration of the Rotronic AC3011 Masterbox For setting of the network configuration (DHCP, IP address, device name etc.), please follow the instructions of Lighthouse ( Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices Select Lighthouse ApexR5 (See following figure) and click Search Device Figure 37: Device select of Lighthouse ApexR ROTRONIC AG Bassersdorf Switzerland Page 27 of 39

28 3.5.8 Use of AC3011 Masterbox The AC3011 Masterbox is a device that is used to add RS485 devices into an ethernet network. To use the AC3011 as such a RS485 <-> LAN converter, it is necessary do know the network settings of the AC3011 as (DHCP, IP address, Device name etc.). To get this information, please use the Digi Device Discovery Tool in the same manner as for HF4, 5, 6, 8 etc. see above Add AF1 AF1 is a device with a RS485 interface. To access the AF1, a RS485 Master as the Rotronic AC3011 Masterbox is necessary. Furthermore the DIP switchs 6-8 of the AF1 need to be set to define the bus address see as follows Figure 38: AF1 Modbus settings Network configuration of the Rotronic AC3011 Masterbox The ethernet configuration of the AC3011 Masterbox need to be set as well in the same manner as for HF4, 5, 6, 8 etc. using the Digi Device Discovery Tool see above. Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices 2016 ROTRONIC AG Bassersdorf Switzerland Page 28 of 39

29 Select AF1, type IP address of the AC3011 master and activate the AC3011 master (See following figure) and click Search Device Figure 39: Device select of AF1 Please configure now the device (name, measurement settings etc. see the following figure). Figure 40: RMS device settings of a AF ROTRONIC AG Bassersdorf Switzerland Page 29 of 39

30 Add BF2 BF2 is a device with a RS485 interface. To access the BF2, a RS485 Master as the Rotronic AC3011 Masterbox is necessary. Network configuration of the Rotronic AC3011 Masterbox The ethernet configuration of the AC3011 Masterbox need to be set as well in the same manner as for HF4, 5, 6, 8 etc. using the Digi Device Discovery Tool see above. Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices Select BF2 and type IP address of the AC3011 master and activate the AC3011 master (See following figure) and click Search Device Figure 41: Device select of BF ROTRONIC AG Bassersdorf Switzerland Page 30 of 39

31 Please configure now the device (name, measurement settings etc. see the following figure). Figure 42: RMS device settings of a BF Add Airy P231 Particle counter Airy P231 Particle counter is a device with a RS485 interface. To access the Airy P231, a RS485 Master as the Rotronic AC3011 Masterbox is necessary. Network configuration of the Rotronic AC3011 Masterbox The ethernet configuration of the AC3011 Masterbox need to be set as well in the same manner as for HF4, 5, 6, 8 etc. using the Digi Device Discovery Tool see above. Add into the RMS Web Software Click on Tools -> Setup Choose RMS Converter -> Click Add/Search at Devices 2016 ROTRONIC AG Bassersdorf Switzerland Page 31 of 39

32 Select Airy P231 and type IP address of the AC3011 master and activate the AC3011 master (See following figure) and click Search Device Figure 43: Device select of an Airy P231 Please configure now the device (name, measurement settings etc. see the following figure). Figure 44: RMS device settings of a Airy P ROTRONIC AG Bassersdorf Switzerland Page 32 of 39

33 4 Firmware-Update RMS-Converter A firmware update of the RMS Converter can be done using the RMS Server Software or the RMS CONFIG. Firmware updates can be downloaded at Firmware Update via RMS Software Main menu -> TOOLS -> SETUP -> select the RMS Converter for the FW update Options -> Firmware Update -> anwählen. Figure 45: Option -> FW update The RMS software compares the actual FW version of the device with the latest FW file version and decides if a FW update is executable. Figure 46: Feedback from the RMS system During FW update: Figure 477: FW update running After successful FW update: Figure 488: FW update successful 2016 ROTRONIC AG Bassersdorf Switzerland Page 33 of 39

34 4.2 Firmware Update per RMS-CONFIG Tool After adding the RMS Converter to the RMS-CONFIG, it appears: Figure 49: RMS Converter FW update via RMS CONFIG 2016 ROTRONIC AG Bassersdorf Switzerland Page 34 of 39

35 Please click Settings Figure 50: RMS Converter FW update via RMS CONFIG Remark: Please check if the RMS Converter is disabled within the RMS web software. Figure 51: RMS Converter disabled 2016 ROTRONIC AG Bassersdorf Switzerland Page 35 of 39

36 Click FW Update -> Dialog windows opens to choose the FW file. The Update starts automatically. Figure 52: Choose the FW file After finish of the FW update Figure 53: FW update sucessful finished 2016 ROTRONIC AG Bassersdorf Switzerland Page 36 of 39

37 5 Technical Specification General Device type Dimensionen RMS device to integrate Rotronic devices (earlier generation) and 3 rd party devices. 94 x 78 x 30 mm Nb. of measuring points Max. 100 Compatible products HF4, HF5, HF6, HF8, HLNT, PF4/5, CRP5, HL-RC (GP FlexGate2 433MHz, GP FlexGate2 US 915MHz) AF1 (RS485) via AC3011 Masterbox BF2 (RS485) via AC3011 Masterbox Airy P231 - Particle counter Lighthouse ApexR5 - Particle counter RMS-8ADC-L-R-A Power supply and plug Power supply voltage Electrical connection 5 VDC Via 230AC/5VDC power supply Digital interface Interface type Protocol Ethernet MODBUS TCP RoASCII Customer specific Konformitäten EMC directive Soldering material FDA / GAMP- directives EMC-directive: 2004/108/EC Lead free (RoHS-directive 2011/65/EU) FDA CFR21 Part 11 / GAMP5 Operating conditions Storage- and transport Operation C / %rf, not condensing C / %rf, not condensing 2016 ROTRONIC AG Bassersdorf Switzerland Page 37 of 39

38 6 Further documents Dokumentname E-IM-RMS-WEB E-SM-RMS-WEB E-OM-RMS-WEB Inhalt System installation manual System startup manual System operation manual 2016 ROTRONIC AG Bassersdorf Switzerland Page 38 of 39

39 7 Document Version Version Date Notes V1.0 February 2017 First version V1.2 January 2018 Sec. version 2016 ROTRONIC AG Bassersdorf Switzerland Page 39 of 39

RMS Mini Wireless Data Logger

RMS Mini Wireless Data Logger RMS Mini Wireless Data Logger 2016 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply...

More information

RMS Analog Input Module

RMS Analog Input Module RMS Analog Input Module 2017 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 WEB SERVER STRUCTURE... 3 2 FUNCTION BUTTON P... 10 3 Integration in the RMS System... 11 4 Document Version... 14 2017

More information

RMS Mini Wireless Data Logger

RMS Mini Wireless Data Logger 2018 ROTRONIC AG Bassersdorf Switzerland Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Mini Data Logger... 5 1.4 Power Supply... 5 1.5 Measured Parameters...

More information

2016 ROTRONIC AG Bassersdorf Switzerland. RMS Data Logger

2016 ROTRONIC AG Bassersdorf Switzerland. RMS Data Logger 2016 ROTRONIC AG Bassersdorf Switzerland RMS Data Logger Table of Contents 1 Overview... 3 1.1 RMS System Overview... 3 1.2 Device Overview... 4 1.3 RMS Data Logger... 5 1.4 Power Supply... 5 1.5 Measured

More information

PCD DIGITAL Differential pressure probe

PCD DIGITAL Differential pressure probe Differential pressure probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information... 6 3.1 Power supply...

More information

Avoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries

Avoid experiments in monitoring important parameters. Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries Avoid experiments in monitoring important parameters Measuring instruments and solutions for the pharmaceutical, medical and healthcare industries ABOUT ROTRONIC Swiss precision at the highest level Founded

More information

Rotronic Monitoring System Technical paper Version 1.0. Rotronic Monitoring System - Technical paper - Understanding RMS from an IT perspective

Rotronic Monitoring System Technical paper Version 1.0. Rotronic Monitoring System - Technical paper - Understanding RMS from an IT perspective Version 1.0 Rotronic Monitoring System - Technical paper - Understanding RMS from an IT perspective 2 Abbreviations CFR CL CS FAT FDA FRS FS Code of Federal Regulations Change Log Configuration Specification

More information

HygroClip DIGITAL Humidity and temperature probe

HygroClip DIGITAL Humidity and temperature probe HygroClip DIGITAL Humidity and temperature probe 2016 ROTRONIC AG Bassersdorf Switzerland Contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Variants... 4 3 General information...

More information

RMS Monitoring Software System Operation

RMS Monitoring Software System Operation RMS Monitoring Software System Operation 2017 ROTRONIC AG Bassersdorf Switzerland 2017 ROTRONIC AG Bassersdorf Switzerland Page 2 of 27 Contents Contents... 3 1 Overview... 4 1.1 System Requirements...

More information

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP Plus-X I/O Units Manual Supplement Configuring Units with and without DHCP Table of Contents Introduction... 1 Initial Connection Using DHCP... 1 Initial Connection Without DHCP... 2 Set a Static IP Address...

More information

RMS Monitoring Software System Operation

RMS Monitoring Software System Operation System Operation 2016 ROTRONIC AG Bassersdorf Switzerland Contents Contents... 2 1 Overview... 3 1.1 System Requirements... 3 1.1.1 Browser... 3 2 System Login... 4 3 Data Views... 5 3.1 Alarm Symbols...

More information

Docking Stations DS-U1, DS-U2, DS-U4, DS-U4-WL and DS-U Adjustment and configuration procedure for the analog inputs

Docking Stations DS-U1, DS-U2, DS-U4, DS-U4-WL and DS-U Adjustment and configuration procedure for the analog inputs Page 1 of 17 Docking Stations DS-U1, DS-U2, DS-U4, DS-U4-WL and DS-U4-4-20 Adjustment and configuration procedure for the analog Page 2 of 17 Table of contents 1 Foreword... 3 2 Configuration examples...

More information

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide VxI Power Ltd. IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide 01/12/2015 Document Number: 14970-020A Issue Number: 2 Contents 1.0 Device Overview... 2 2.0 Getting Started... 3 2.1 Connecting the Device...

More information

HW4 Software version 3. Device Manager TF5 Temperature Transmitter

HW4 Software version 3. Device Manager TF5 Temperature Transmitter Page 1 of 15 HW4 Software version 3 Device Manager 2010; E-M-HW4v3-F2-017_10 Table of contents Page 2 of 15 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 DEVICE MANAGER... 4 3.1 Device Manager

More information

Installation. ProSAFE Wireless Controller Model WC7500 and Model WC7600

Installation. ProSAFE Wireless Controller Model WC7500 and Model WC7600 Installation ProSAFE Wireless Controller Model WC7500 and Model WC7600 Hardware Overview Before you install your wireless controller, familiarize yourself with its LEDs, buttons, and ports. Digital access

More information

RMS Monitoring Software System Installation

RMS Monitoring Software System Installation System Installation 2017 ROTRONIC AG Bassersdorf Switzerland 2017 ROTRONIC AG Bassersdorf Switzerland Page 2 of 40 Contents Contents... 3 1 Overview... 4 1.1 Minimum System Requirements... 4 2 Update to

More information

PCAN-Gateway Quick Start Guide

PCAN-Gateway Quick Start Guide PCAN-Gateway Quick Start Guide Congratulations...... on your new PCAN-Gateway. This guide covers the basic configuration and operation of the PCAN-Gateway product family. Documentation Detailed documentation

More information

Docking Station DS-U4WEB with web server version 1 Instruction Manual

Docking Station DS-U4WEB with web server version 1 Instruction Manual Page 1 of 15 Docking Station DS-U4WEB with web server version 1 Page 2 of 15 Table of contents 1 Overview... 3 2 Description... 3 2.1 Connector identification... 3 2.2 Probe inputs... 4 2.3 Logical inputs

More information

HW4 Software version 3. Device Manager HygroClip DI

HW4 Software version 3. Device Manager HygroClip DI Page 1 of 10 HW4 Software version 3 2010 E-M-HW4v3-F1-003_10 Table of contents Page 2 of 10 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 DEVICE MANAGER... 4 3.1 Device Manager Menu Bar... 5

More information

Cassia E1000/X1000/C1000 Quick Start Guide

Cassia E1000/X1000/C1000 Quick Start Guide Cassia E1000/X1000/C1000 Quick Start Guide Step One Connect your laptop/pc to your Bluetooth router Check your Bluetooth router s MAC address on the bottom of the router, as noted in Figure 1 below. Then

More information

CLEAN ROOM PANEL - CRP5

CLEAN ROOM PANEL - CRP5 RELIABLE MEASUREMENTS IN CLEAN ROOMS Measures differential pressure, humidity and temperature Designed specifically for clean rooms Removable humidity and temperature probes for simpler adjustment and

More information

How to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet

How to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet ABB SOLAR INVERTERS How to connect ABB Ethernet inverters with Data Logger over Ethernet Basic information -05 Data Logger is a monitoring device developed by ABB. -05 Data Logger can be used to monitor

More information

1. Connect the AD375 shaft encoder to the iris350 FX as shown in the diagram below.

1. Connect the AD375 shaft encoder to the iris350 FX as shown in the diagram below. Practical Exercise - SDI-12 connection to iris 350FX 1. Connect the AD375 shaft encoder to the iris350 FX as shown in the diagram below. 2. Connect the iris350fx to a laptop via an RS232 null-modem cable.

More information

BIPAC-5100 / 5100W (Wireless) ADSL Router

BIPAC-5100 / 5100W (Wireless) ADSL Router BIPAC-5100 / 5100W (Wireless) ADSL Router Quick Start Guide Billion BIPAC-5100 / 5100W ADSL Router For more detailed instructions on configuring and using the (Wireless) ADSL Firewall Router, please refer

More information

BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide

BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router with 4-port 10/100M Switch Quick Start Guide Billion BIPAC-6500 / 6500W (Wireless) Broadband VPN Firewall Router For more detailed instructions

More information

RMS WIRELESS MINI LOGGER

RMS WIRELESS MINI LOGGER RMS WIRELESS MINI LOGGER COMPACT, VERSATILE & FLEXIBLE Various models to measure and log humidity, temperature, lux and electrical values Stores up to 10 000 values Fail safe, due to internal battery and

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS S Simplicity Transporter Setup Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS S Simplicity Transporter Setup Instructions 525683-UAI-C-0911 ACCESSORY KIT INSTALLATION INSTRUCTIONS S1-33109119000 Simplicity Transporter Setup Instructions A remote Internet connection to a network of Simplicity control(s) allows you the ability

More information

HW4 Software version 2. Probe Adjustment function Legacy devices

HW4 Software version 2. Probe Adjustment function Legacy devices Page 1 of 12 HW4 Software version 2 Probe Adjustment function Page 2 of 12 Table of contents 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 3 PROBE ADJUSTMENT... 4 3.1 Overview... 5 3.2 Menu Bar...

More information

Data logger systems from ROTRONIC

Data logger systems from ROTRONIC Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485

More information

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video

More information

Quick Installation Guide. Live! Titanium

Quick Installation Guide. Live! Titanium Quick Installation Guide Live! Titanium Contents 1. Live! overview... 2. Installation... 3. Network setup... 4. Wireless setup... 5. Configuring your Live!... 6. Troubleshooting... 2 4 7 8 9 10 1 1. Live!

More information

HygroLog HL20 and HL21 Data Logger. User Guide

HygroLog HL20 and HL21 Data Logger. User Guide Page 1 of 23 HygroLog HL20 and HL21 Data Logger Page 2 of 23 Table of contents: 1. Overview... 4 1.1 General... 4 2. General description... 5 2.1 Models... 5 2.2 Required accessories... 5 2.3 Batteries...

More information

BiPAC 7300VP/ 7300VGP

BiPAC 7300VP/ 7300VGP BiPAC 7300VP/ 7300VGP VoIP/(802.11g) ADSL2+ Router Quick Start Guide Billion BiPAC 7300VGP Series ADSL2+ Router For more detailed instructions on configuring and using the VoIP/802.11g ADSL2+ Router,

More information

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24

MDNET-5W. Wi-Fi/Ethernet/RS485 Converter Operation Manual. Version /03/24 MDNET-5W Wi-Fi/Ethernet/RS485 Converter Operation Manual Version 01.00 2016/03/24 I. Features & Specification Features: Connect RS485 devices to Ethernet or Wi-Fi network Connect Ethernet device to Wi-Fi

More information

PRELIMINARY DESCRIPTION

PRELIMINARY DESCRIPTION RTD to Modbus TCP Phone: +1 561 779 5660 email:datexel@datexel.com www.datexel.com User Guide MODBUS TCP/IP protocol Firmware Version : 8300 PRELIMINARY DESCRIPTION Modbus TCP/IP server 4 isolated channels

More information

HygroLog HL20 and HL21 Data Logger. User Guide

HygroLog HL20 and HL21 Data Logger. User Guide Page 1 of 17 HygroLog HL20 and HL21 Data Logger Page 2 of 17 Table of contents: 1. Overview... 3 1.1 General... 3 2. General description... 4 2.1 Models... 4 2.2 Required accessories... 4 2.3 Batteries...

More information

Quick Start Guide for Standalone EAP

Quick Start Guide for Standalone EAP Quick Start Guide for Standalone EAP CHAPTERS 1. Determine the Management Method 2. Build the Network Topology 3. Log In to the EAP 4. Edit the SSID 5. Configure and Manage the EAP This guide applies to:

More information

Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system.

Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system. Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system. Please follow these steps to ensure that any changes made by your previous

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router FEATURE HIGHLIGHTS GPRS/G/4G Cellular Protocol Gateway with extensive LTE Band support: EU Model: 2100/1800/850/2600/900/800MHz

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual page 2 of 15 Contents: Overview... 2 Models... 3 Power... 4 Probes... 4 Connector identification... 5 Pin-out diagrams... 6

More information

HRM-0800 Instruction Manual

HRM-0800 Instruction Manual HRM-0800 Instruction Manual Table of Contents 1 Highway Addressable Remote Transducer (HART ) 4 2 General Specifications 5 3 Dimensions: 6 4 General Description 7 4.1 Introduction 7 4.2 Purpose 8 4.3 Functions

More information

elan-rs485/ /2017 / rev.0 Page 1 of 19

elan-rs485/ /2017 / rev.0 Page 1 of 19 Page 1 of 19 Introduction... 4 Device description... 4 Examples connection... 5 Installing, IP address... 6 Logging to the web interface... 7 Settings... 8 Settings description of functions... 9 Devices

More information

HygroClip2 ADVANCED Humidity Temperature Probes

HygroClip2 ADVANCED Humidity Temperature Probes Humidity Temperature Probes 2016 ROTRONIC AG Bassersdorf Switzerland Table of contents 1 Overview... 3 1.1 Hardware and software compatibility... 3 2 Models... 4 3 General description... 18 3.1 Power supply...

More information

1 Hardware Installation

1 Hardware Installation 1 Hardware Installation 1.1 Choosing the Best Location for Wireless Operation Many environmental factors may affect the effective wireless function of the DSL Router. If this is the first time that you

More information

WHG311 V1.03. Secure WLAN Controller

WHG311 V1.03. Secure WLAN Controller WHG311 V1.03 Secure WLAN Controller Copyright Notice This document is protected by USA copyright laws and other laws and is the property of 4IPNET, INC. You may not copy, reproduce, distribute, publish,

More information

BiPAC 5200 Series. (802.11g) ADSL2+ Modem/Router. Quick Start Guide

BiPAC 5200 Series. (802.11g) ADSL2+ Modem/Router. Quick Start Guide BiPAC 5200 Series (802.11g) ADSL2+ Modem/Router Quick Start Guide Billion BiPAC 5200 Series ADSL2+ Modem/Router For more detailed instructions on configuring and using the (802.11g) ADSL2+ Modem/Router,

More information

Quick Start Guide. System Release 1.0. Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link

Quick Start Guide. System Release 1.0. Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link Quick Start Guide System Release 1.0 Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link SPECIAL SOFTWARE UPGRADE NOTICE Important! All users of

More information

HW4 Software version 3. HP23 Humidity Temperature Indicator

HW4 Software version 3. HP23 Humidity Temperature Indicator Page 1 of 27 HW4 Software version 3 2010-2011; E-M-HW4v3-F2-012_11 Page 2 of 27 Table of contents 1 ORGANIZATION OF THE HW4 MANUALS... 3 2 OVERVIEW... 4 2.1 Functions and settings overview... 4 2.2 Detecting

More information

GV-I/O Box 4E. Contents

GV-I/O Box 4E. Contents GV-I/O Box 4E Contents 1.1 Key Features... 2 1.2 System Requirements... 2 1.3 Packing List... 2 1.4 Overview... 3 1.5 Connecting to PC... 4 1.5.1 RS-485 Wiring... 4 1.6 Assigning Device ID to GV-I/O Box

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information

More information

TH800DS CONTROLLER MANUAL

TH800DS CONTROLLER MANUAL TH800DS CONTROLLER MANUAL 1 Introduction 3 1.1 Overview 3 1.2 Features 4 1.3 Specifications 4 1.4 Panel 5 1.4.1 Front Panel 5 1.4.2 Rear Panel 6 2 Hardware Installation 7 3 Accessing the Device 8 3.1 Before

More information

Configuring Cisco Mobility Express controller

Configuring Cisco Mobility Express controller There are multiple ways one can configure a Cisco Mobility Express controller. They are as follows: 1 CLI Setup Wizard 2 Over the Air Setup Wizard 3 Network Plug and Play CLI Setup Wizard, page 1 Over-the-Air

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

Installing the Linksys app on your Android device via the Google Play Store and Google Play Website

Installing the Linksys app on your Android device via the Google Play Store and Google Play Website User Guide Installing the Linksys app on your Android device via the Google Play Store and Google Play Website The Linksys app is a free mobile application that allows you to securely access your home

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

Quick Start Guide. 1 Introduction. GV-Box Camera GV-BX120D / 220D / 320D. Packing List

Quick Start Guide. 1 Introduction. GV-Box Camera GV-BX120D / 220D / 320D. Packing List 1 Introduction Welcome to the GV-Box Camera Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Box camera (GV-BX120D / 220D / 320D).

More information

NET-IP-PRO. User Manual. Web-Based Control for Smart-AVI Products

NET-IP-PRO. User Manual. Web-Based Control for Smart-AVI Products NET-IP-PRO User Manual Web-Based Control for Smart-AVI Products Remotely control Smart-AVI product operations over a local area network or via the Internet from anywhere in the world TABLE OF CONTENTS

More information

US-IP2. Monitoring Receiver

US-IP2. Monitoring Receiver US-IP2 Monitoring Receiver (and IP receiver card) Programming Manual 28 / 01 / 2014 CONTENT 1. INTRODUCTION...3 2. SYSTEM STRUCTURE...4 3. FIRST STEPS...4 Connectors and LED signals...5 4. SYSTEM PROGRAMMING

More information

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch...

Contents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch... Contents GV-I/O Box 8 Ports...2 1. Key Features... 2 2. Compatible Software... 2 3. Packing List... 2 4. Overview... 3 5. DIP Switch... 3 6. Connections to PC... 4 6.1 Installing USB Driver... 5 6.2 Assigning

More information

WAP9112/9114 Quick Start Guide

WAP9112/9114 Quick Start Guide WAP9112/9114 Quick Start Guide Release 7.6 NN47252-308 Issue 02.01 March 2016 Contents Chapter 1: Introduction... 3 Chapter 2: Required Software Components... 4 Chapter 3: Installing or Upgrading Wireless

More information

Configuring your MikroTik as a Standard LucidView Enforcer

Configuring your MikroTik as a Standard LucidView Enforcer MANUAL Configuring your MikroTik as a Standard LucidView Enforcer Version 6 Table of Contents STANDARD LUCIDVIEW ENFORCER 2 Guide version 2 About 2 Standard vs. Bolt-On Enforcer 2 GENERATING & DOWNLOADING

More information

QUICK-START EMU M-BUS CENTER ENGLISH

QUICK-START EMU M-BUS CENTER ENGLISH QUICK-START EMU M-BUS CENTER ENGLISH EN QUICK-START INSTRUCTIONS CONTENT INSTALLATION...3 Power supply...3 Network connection...4 Connect meter (M-BUS)...4 START-UP PROCEDURE...5 Default network configuration...5

More information

BiPAC 6404VP/VGP. VoIP/(802.11g) Broadband Firewall Router. Quick Start Guide

BiPAC 6404VP/VGP. VoIP/(802.11g) Broadband Firewall Router. Quick Start Guide BiPAC 6404VP/VGP VoIP/(802.11g) Broadband Firewall Router Quick Start Guide VoIP/(802.11g) Broadband Firewall Router For more detailed instructions on configuring and using the VoIP/(802.11g) Broadband

More information

MTXM2M. Modems, Gateways & Routers for M2M-IoT

MTXM2M. Modems, Gateways & Routers for M2M-IoT MTXM2M Modems, Gateways & Routers for M2M-IoT Wireless M2M-IoT devices Designed and manufactured by Matrix Electronica, awarded 2015 Innovative Company. MTXM2M offers high tech M2M and IoT devices & software

More information

LAB: Configuring LEAP. Learning Objectives

LAB: Configuring LEAP. Learning Objectives LAB: Configuring LEAP Learning Objectives Configure Cisco ACS Radius server Configure a WLAN to use the 802.1X security protocol and LEAP Authenticate with an access point using 802.1X security and LEAP

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway FEATURE HIGHLIGHTS Extensive G and LTE Band Support - EU: 2100/1800/850/2600/900/800MHz (B1/B/B5/B7/B8/B20) - US: 1900/AWS/850/700/700/1900MHz

More information

F650 Firmware Release Notes / History (Rev 10)

F650 Firmware Release Notes / History (Rev 10) 1.00 2.00 First version of the product (Basic Model F1G0) Full protection scheme F650BABF1G0HI August 30 th 2002 1.11 2.00 New model F2G0 (inputs and outputs board type 2) F650BABF2G0HI October 14 th 2002

More information

How to assign an IP address and access your device

How to assign an IP address and access your device User Manual Table of Contents Get started................................................ 3 Browser support................................................ 3 About default IP addresses........................................

More information

BiPAC 7300(G) (802.11g) ADSL2+ Router. Quick Start Guide

BiPAC 7300(G) (802.11g) ADSL2+ Router. Quick Start Guide BiPAC 7300(G) (802.11g) ADSL2+ Router Quick Start Guide Billion BiPAC 7300(G) ADSL2+ Router For more detailed instructions on configuring and using the (802.11g) ADSL2+ Router, please refer to the on-line

More information

310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide

310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide 310 SERIES LAYER 2 MANAGED NETWORK SWITCHES AN-310-SW-F/R-8 AN-310-SW-F/R-16 AN-310-SW-F/R-24 AN-310-SW-F/R-8-POE AN-310-SW-F/R-16-POE AN-310-SW-F/R-24-POE FCC Warning Changes or modifications not expressly

More information

Troubleshooting Lightweight Access Points

Troubleshooting Lightweight Access Points CHAPTER 4 This chapter provides troubleshooting procedures for basic problems with the 1130AG series lightweight access point (model: AIR-LAP1131AG or AIR-LAP1131G). For the most up-to-date, detailed troubleshooting

More information

Intelligence. humidity and temperature probes. Introducing AirChip Digital Technology.

Intelligence. humidity and temperature probes. Introducing AirChip Digital Technology. humidity and temperature probes Unique Sensing Intelligence. Introducing AirChip Digital Technology. Innovation in Humidity and Temperature Measurement Relative humidity, temperature measurement and dew

More information

POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security. Business, Opportunities and Risks

POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security. Business, Opportunities and Risks POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security Business, Opportunities and Risks Overview Cloud, Big Data & Cyber Security Summary Cloud: scalable, adaptable, cost effective but not under

More information

PRELIMINARY DESCRIPTION

PRELIMINARY DESCRIPTION Modbus TCP to Relay output and 8 Digital inputs. Phone: +1 561 779 5660 email:datexel@datexel.com www.datexel.com User Guide MODBUS TCP/IP protocol Firmware Version : 80 PRELIMINARY DESCRIPTION Modbus

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

GCAN-211. WiFi-CAN converter. User Manual. Document version:v3.01 (2017/03/05)

GCAN-211. WiFi-CAN converter. User Manual. Document version:v3.01 (2017/03/05) GCAN-211 WiFi-CAN converter User Manual Document version:v3.01 (2017/03/05) Contents 1. Introduction... 3 1.1 Overview... 3 1.2 Properties at a glance... 3 2. Installation... 4 2.1 Dimension drawings...

More information

HD IP CAMERA USER GUIDE

HD IP CAMERA USER GUIDE HD IP CAMERA USER GUIDE Support US: support@onwote.com EU: eusupport@onwote.com AU: ausupport@onwote.com Feature Lists 7x24 hours online live HD video preview Remote access via multiple web browsers(ie/firefox,

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O

More information

PDU firmware update manual

PDU firmware update manual PDU firmware update manual Page 1 of 5 Introduction 2 Why frequently update the Firmware? 3 Using the tool 3 Notes 5 Introduction Since the beginning of 2015 the Schleifenbauer PDUs are standard equipped

More information

SMA POWER+ SOLUTION TS4

SMA POWER+ SOLUTION TS4 SMA POWER+ SOLUTION TS4 DISCLAIMER IMPORTANT LEGAL NOTICE This presentation does not constitute or form part of, and should not be construed as, an offer or invitation to subscribe for, underwrite or otherwise

More information

Deployment of a new M-Lab site

Deployment of a new M-Lab site Deployment of a new M-Lab site Deployment of a new M-Lab site Scope of the document HW deployment - on-site CHECKLIST for on-site staff, BEFORE going to the site SW configuration - on-site and off-site

More information

Modbus TCP + Ethernet EN

Modbus TCP + Ethernet EN Version 0.10 2015 dieentwickler Elektronik GmbH Linzer Straße 4, 4283 Bad Zell / AUSTRIA Telefon: +43 7263 20900-0, Telefax: +43 7263 20900-4 office@dieentwickler.at, www.dieentwickler.at Preface Table

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

PRELIMINARY DESCRIPTION. (*)Coil (Hex) 0x00A1 0x00A2 0x00A3

PRELIMINARY DESCRIPTION. (*)Coil (Hex) 0x00A1 0x00A2 0x00A3 DigitalinputtoEthernet Phone: +1 561 779 5660 email:datexel@datexel.com www.datexel.com User Guide MODBUS TCP/IP protocol Firmware Version : 8200 PRELIMINARY DESCRIPTION Modbus TCP/IP server 16 Digital

More information

Inmarsat BGAN M2M Hughes 9502 Terminal Setup Guide

Inmarsat BGAN M2M Hughes 9502 Terminal Setup Guide Inmarsat BGAN M2M Hughes 9502 Terminal Setup Guide pivotel.com.au 1300 882 448 Page 1 Inmarsat BGAN M2M Hughes 9502 - Terminal Setup Guide Terminal Setup Steps: Step 1. Insert your Pivotel BGAN M2M SIM

More information

Installation Instructions Fig. 3 Side View. No. Label Operation

Installation Instructions Fig. 3 Side View. No. Label Operation One-Camera IP Video Server In G Out G D+ D- Installation Instructions 1507280 Part Number: CM2002 - One-Camera IP Video Server CM2002 IP Video Server Features In G Out G D+ D- DO G DI G Out In Video In

More information

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

HM4. Humidity and Temperature Probe with Heated Sensor. Instruction Manual E-M-HM4-V1_12. HM4 Humidity and Temperature Probe with Heated Sensor

HM4. Humidity and Temperature Probe with Heated Sensor. Instruction Manual E-M-HM4-V1_12. HM4 Humidity and Temperature Probe with Heated Sensor Page 1 of 41 HM4 Humidity and Temperature Probe with Page 2 of 41 Table of Contents 1 Overview... 4 1.1 Scope... 5 1.2 Background Information on the Principle of Measurement... 5 2 Mechanical Variants

More information

210 SERIES WEBSMART NETWORK SWITCHES Quick Start Guide AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE

210 SERIES WEBSMART NETWORK SWITCHES Quick Start Guide AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE 210 SERIES WEBSMART NETWORK SWITCHES AN-210-SW-F/R-8-POE AN-210-SW-F/R-16-POE AN-210-SW-F/R-24-POE AN-210-SW-F-48-POE Araknis Networks 210 Series Websmart Network Switches FCC Warning Changes or modifications

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Revolabs HD Firmware Release Notes Rev

Revolabs HD Firmware Release Notes Rev Contents: Revolabs HD Firmware Release Notes Rev. 2.6.26 9.10.2012 Purpose...2 Scope...2 About this Release...2 Upgrading...2 Compatible Products...2 References...4 Firmware Enhancements...4 Past Revisions...5

More information

EasyIO FW 08VUser Reference

EasyIO FW 08VUser Reference EasyIO FW 08VUser Reference 1 Document Change Log 26 th Dec 2016 Document created. 2 Disclaimer EasyIO FW 08V is a product by EasyIO Holdings Pte Ltd The EasyIO FW 08V was built on the Sedona Framework.

More information

I-Fly Wireless Broadband Router

I-Fly Wireless Broadband Router with 4 Fast Ethernet ports + 1 Wan port Quick Start Guide A02-WR-54G/G2 (November 2003)V1.00 For more detailed instructions on configuring and using the I- Storm Lan Router ADSL, please refer to the online

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway FEATURE HIGHLIGHTS Extensive G and LTE Band Support - EU: 2100/1800/850/2600/900/800MHz (B1/B/B5/B7/B8/B20) - US: 1900/AWS/850/700/700/1900MHz

More information

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05

WRTU Client User Manual. Date: 29 May, 2014 Document Revision: 1.05 WRTU Client User Manual Date: 29 May, 2014 Document Revision: 1.05 2014 by BiPOM Electronics, Inc. All rights reserved. WRTU Client User Manual. No part of this work may be reproduced in any manner without

More information

Netbiter EC300 Series

Netbiter EC300 Series Netbiter EC300 Series USER MANUAL SCM-1202-012 2.2 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of

More information