Foundry ServerIron Hardware Installation Guide

Size: px
Start display at page:

Download "Foundry ServerIron Hardware Installation Guide"

Transcription

1 Foundry ServerIron Hardware Installation Guide ServerIron 4G Series ServerIronGT C Series ServerIronGT E Series ServerIron 350 & 350-PLUS ServerIron 450 & 450-PLUS ServerIron 850 & 850-PLUS 4980 Great America Parkway Santa Clara, CA Tel December 2006

2 Copyright 2006 Foundry Networks, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means graphic, electronic or mechanical, including photocopying, recording, taping or storage in an information retrieval system without prior written permission of the copyright owner. The trademarks, logos and service marks ("Marks") displayed herein are the property of Foundry or other third parties. You are not permitted to use these Marks without the prior written consent of Foundry or such appropriate third party. Foundry Networks, BigIron, FastIron, IronView, JetCore, NetIron, ServerIron, TurboIron, IronWare, EdgeIron, the Iron family of marks and the Foundry Logo are trademarks or registered trademarks of Foundry Networks, Inc. in the United States and other countries. F-Secure is a trademark of F-Secure Corporation. All other trademarks mentioned in this document are the property of their respective owners.

3 Contents CHAPTER 1 ABOUT THIS GUIDE AUDIENCE ORGANIZATION CONVENTIONS RELATED DOCUMENTATION TECHNICAL ASSISTANCE HOW TO GET HELP WEB ACCESS ACCESS TELEPHONE ACCESS CHAPTER 2 PRODUCT OVERVIEW SERVERIRON 350/450/850 FAMILY SERVERIRON 350 AND 350 PLUS SWITCHES SERVERIRON 450 SWITCH AND 450 PLUS SWITCHES SERVERIRON 850 SWITCH AND 850 PLUS SWITCHES SERVERIRONGT C SERIES SSL FAMILY SERVERIRONGT CGX2 SSL SERVERIRONGT CGC16 SSL SERVERIRONGT C2404CF SSL SERVERIRONGT C SERIES FAMILY SERVERIRONGT CGX SERVERIRONGT CGC SERVERIRONGT C2404CF SERVERIRON GTE SSL FAMILY SERVERIRONGT E SERIES FAMILY SERVERIRONGT E SERIES SERVERIRONGT E SERIES PLUS December Foundry Networks, Inc. iii

4 Foundry ServerIron Hardware Installation Guide SERVERIRONGT 10 GIGABIT ETHERNET SYSTEMS SERVERIRONGT C10GX2P SERVERIRONGT E10GX2P SERVERIRONGT E10GX WEB SWITCHING MODULES OVERVIEW WSM MANAGEMENT MODULES SSL WEB SWITCHING MODULES WSM6-SSL-1 MANAGEMENT MODULE WSM6-SSL-2 MANAGEMENT MODULE SSL SERVICE MODULES SRVC-SSL6-1 SERVICE MODULE SRVC-SSL6-2 SERVICE MODULE JETCORE LINE MODULES GIGABIT ETHERNET MODULES GIGABIT ETHERNET MODULES /1000BASE-T MODULE BASE-FX MODULE J-B2404CF 24-PORT 10/100BASE-TX AND 4-PORT COMBO GIGABIT ETHERNET MODULE /100 MBPS ETHERNET MODULE LEDS RJ-45 PINOUTS POWER CONSUMPTION MATRIX RECOMMENDED SOFTWARE RELEASES TECHNICAL SPECIFICATIONS LOAD BALANCING METHODS LAYER 2 SWITCHING CAPABILITIES PROTOCOL SUPPORT STANDARDS COMPLIANCE NETWORK MANAGEMENT SAFETY AGENCY APPROVALS ELECTROMAGNETIC APPROVALS IMMUNITY ENVIRONMENTAL MOUNTING OPTIONS CHAPTER 3 INSTALLING THE SERVERIRON UNPACKING A SYSTEM PACKAGE CONTENTS GENERAL REQUIREMENTS SUMMARY OF INSTALLATION PROCEDURES INSTALLATION PRECAUTIONS GENERAL PRECAUTIONS POWER PRECAUTIONS iv 2006 Foundry Networks, Inc. December 2006

5 PREPARING THE INSTALLATION SITE CABLING INFRASTRUCTURE INSTALLATION LOCATION INSTALLING OR REMOVING DC POWER SUPPLIES (FOR 4-SLOT CHASSIS DEVICES) INSTALLING A DC POWER SUPPLY REMOVING A DC POWER SUPPLY VERIFYING PROPER OPERATION ATTACHING A PC OR TERMINAL ASSIGNING IP ADDRESSES MOUNTING THE SERVERIRON IN AN EQUIPMENT RACK DESKTOP INSTALLATION FOR A SERVERIRON CHASSIS RACK MOUNT INSTALLATION FOR A SERVERIRON 4-SLOT CHASSIS RACK MOUNT INSTALLATION FOR A SERVERIRON 3-SLOT CHASSIS POWERING ON THE SERVERIRON CONNECTING NETWORK DEVICES CABLE LENGTH CONNECTING TO ETHERNET OR FAST ETHERNET HUBS CONNECTING TO WORKSTATIONS, SERVERS, OR ROUTERS TROUBLESHOOTING NETWORK CONNECTIONS TESTING CONNECTIVITY PINGING AN IP ADDRESS TRACING A ROUTE CHAPTER 4 SERVERIRON 4G SERIES PRODUCT OVERVIEW SERVERIRON 4G SERIES COMMON FEATURES COMMON COMPONENTS INSTALLING SERVERIRON 4G SERIES INSTALLATION OVERVIEW INSTALLATION PRECAUTIONS INSTALLING A REDUNDANT POWER SUPPLY INSTALLING A SERVERIRON 4G SERIES DEVICE POWERING ON THE SYSTEM VERIFYING PROPER OPERATION CHECKING THE POWER STATUS ATTACHING A PC OR TERMINAL ASSIGNING PERMANENT PASSWORDS RECOVERING A LOST PASSWORD CONFIGURING AN IP ADDRESS CONNECTING SERVERIRON 4G SERIES CONNECTING NETWORK DEVICES TESTING CONNECTIVITY TROUBLESHOOTING NETWORK CONNECTIONS December Foundry Networks, Inc. v

6 Foundry ServerIron Hardware Installation Guide MANAGING SERVERIRON 4G SERIES MANAGING TEMPERATURE SETTINGS MANAGING FAN SETTINGS AND TEMPERATURE SENSORS DISPLAYING MANAGEMENT MODULE CPU USAGE TECHNICAL SPECIFICATIONS CHASSIS SPECIFICATIONS POWER SUPPLY SPECIFICATIONS CAUTIONS AND WARNINGS CAUTIONS WARNINGS CHAPTER 5 SERVERIRON 4G SERIES DEPLOYMENT GUIDE DEPLOYMENT OVERVIEW DEPLOYMENT SCENARIOS DESIGN 1: HIGHLY AVAILABLE ONE-ARM DESIGN 2A: INLINE WITH HOT-STANDBY HA DESIGN 2B: INLINE WITH SYM-ACTIVE HA AND MULTI-PORT TRUNKS DESIGN 2C: INLINE WITH SYM-ACTIVE HA AND CROSS CONNECTIONS DESIGN 2D: INLINE WITH SYM-ACTIVE HA AND SYNC LINK DESIGN 3A: SSL APPLIANCE MODE DESIGN 3B: SSL APPLIANCE MODE CONFIGURATION DETAILS CHAPTER 6 UPGRADING TO ROUTER/GSLB SOFTWARE ROUTER/GSLB UPGRADE FOR SERVERIRON 4G OPEN THE DEVICE INSTALL THE EEPROM INSTALL THE SOFTWARE ROUTER/GSLB UPGRADE FOR SERVERIRON WSM6/ UPGRADE OVERVIEW INSTALL THE EEPROM INSTALL THE SOFTWARE APPENDIX A CAUTIONS AND WARNINGS...A-1 CAUTIONS... A-1 WARNINGS... A-4 Index vi 2006 Foundry Networks, Inc. December 2006

7 Chapter 1 About this Guide This preface describes the audience, organization, and conventions used in the Foundry ServerIron Hardware Installation Guide. This preface contains the following sections: Audience on page 1-1 Organization on page 1-1 Conventions on page 1-2 Related Documentation on page 1-2 Technical Assistance on page 1-2 Audience This guide is intended for networking professionals who are responsible for installing the ServerIron Series switches. We assume that you are familiar with the basic concepts and terminology of Ethernet, local area networking, and application switching. Organization This guide contains the following: Chapter 1 About this Guide describes the organization of this book. Chapter 2 Product Overview provides a physical and functional overview of the ServerIron hardware features. It describes the switch modules, ports, LEDs, power consumption, and technical specifications. Chapter 3 Installing the ServerIron describes the procedures for installing, connecting, and powering up the ServerIron chassis switches. Chapter 4 ServerIron 4G Series provides a functional overview and describes the procedures for installing, connecting, and powering up the ServerIron stackable switches. Chapter 5 ServerIron 4G Series Deployment Guide describes network design alternatives for the ServerIron 4G series switches. It also gives guidelines for deploying these designs in the field. Chapter 6 Upgrading to Router/GSLB Software describes how to upgrade the EEPROM on ServerIron chassis and 4G stackable switches. Appendix A lists cautions and warnings in English, German, French, and Spanish. December Foundry Networks, Inc. 1-1

8 Foundry ServerIron Hardware Installation Guide Conventions This guide uses the following typographical conventions to describe information: Italic Bold code Bold Highlights the title of another publication or emphasizes a word or phrase. Indicates code that is entered exactly as shown. Indicates a command or keyword that can be entered exactly as is. NOTE: A note emphasizes an important fact or calls your attention to a dependency. WARNING: A warning calls your attention to a possible hazard that can cause injury or death. CAUTION: A caution calls your attention to a possible hazard that can damage equipment. Related Documentation For more information, refer to the following Foundry Networks ServerIron documentation: ServerIron Chassis L4-7 Software Configuration Guide describes the Layer 4-7 feature technologies supported for the chassis devices (not XL devices) in the ServerIron product line. Foundry ServerIron Firewall Load Balancing Guide provides detailed feature descriptions, procedures, and application examples for Firewall Load Balancing (FWLB). Foundry Security Guide provides procedures for securing management access to Foundry devices and for protecting against Denial of Service (DoS) attacks. Foundry Diagnostic Guide provides descriptions of diagnostic commands that can help you diagnose and solve issues on Foundry devices. Foundry Management Information Base Reference presents the Simple Network Management Protocol (SNMP) Management Information Base (MIB) objects that are supported on Foundry devices. Technical Assistance This section contains the following sections: How to Get Help on page 1-2 Web Access on page 1-2 Access on page 1-3 Telephone Access on page 1-3 How to Get Help Foundry Networks technical support will ensure that the fast and easy access that you have come to expect from your Foundry Networks products will be maintained. Web Access Foundry Networks, Inc. December 2006

9 About this Guide Access Technical requests can also be sent to the following address: Telephone Access TURBOCALL ( ) United States Outside the United States December Foundry Networks, Inc. 1-3

10 Foundry ServerIron Hardware Installation Guide Foundry Networks, Inc. December 2006

11 Chapter 2 Product Overview This chapter contains the following sections: ServerIron 350/450/850 Family on page 2-1 ServerIronGT C Series SSL Family on page 2-4 ServerIronGT C Series Family on page 2-6 ServerIronGT E Series Family on page 2-8 ServerIronGT 10 Gigabit Ethernet Systems on page 2-11 Web Switching Modules on page 2-13 SSL Web Switching Modules on page 2-15 SSL Service Modules on page 2-16 JetCore Line Modules on page 2-17 Power Consumption Matrix on page 2-22 Recommended Software Releases on page 2-24 Technical Specifications on page 2-25 NOTE: ServerIron 4G Series is described in Chapter 4 ServerIron 4G Series on page 4-1. ServerIron 350/450/850 Family This section contains the following sections: ServerIron 350 and 350 PLUS Switches on page 2-2 ServerIron 450 Switch and 450 PLUS Switches on page 2-2 ServerIron 850 Switch and 850 PLUS Switches on page 2-3 ServerIron 350, 450, and 850 switches provide high performance Layer 4 7 application switching and traffic management. These systems feature Foundry's highest performance WSM6/WSM7 management module. A choice of 10/100 Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet modules can be added for high-density connectivity into the network and to the server farms. This family features a choice of 3-, 4- and 8-slot chassis products for a choice of size, port density and future expandability options. December Foundry Networks, Inc. 2-1

12 Foundry ServerIron Hardware Installation Guide NOTE: An SSL service module (SRVC-SSL6-1 or SRVC-SSL6-2) can be added for integrated SSL. ServerIron 350 and 350 PLUS Switches The ServerIron 350 Family is a series of compact, modular, 3-slot, Layer 4 7 application switches that come preequipped with a WSM6 (ServerIron 350) or WSM7 (ServerIron 350 PLUS). The ServerIron 350/350 PLUS switches can be equipped with up to two JetCore line modules and support 10/100 Ethernet, Gigabit Ethernet (copper and fiber media), and 10 Gigabit Ethernet. The ServerIron 350/350 PLUS switches ship with one power supply (rear pluggable) and redundant power supplies are optionally available. This switch features a removable fan tray. NOTE: A second WSM6 management module can be added to double the performance and provide redundancy of a SeverIron 350. A second WSM7 management module can be added to double the performance and provide redundancy of a SeverIron 350 PLUS. WARNING: When removing a fan tray, be careful not to touch the spinning fan. Figure 2.1 shows the front panel of a ServerIron 350 switch. Figure 2.1 ServerIron 350 Switch ServerIron 450 Switch and 450 PLUS Switches The ServerIron 450 Family is a series of 4-slot, Layer 4 7 application switches that come pre-equipped with a WSM6 (ServerIron 450) or WSM7 (ServerIron 450 PLUS). The ServerIron 450/450 PLUS switches can be equipped with up to three JetCore line modules and support 10/ 100 Ethernet, Gigabit Ethernet (copper and fiber media), and 10 Gigabit Ethernet. The ServerIron 450/450 PLUS switch ships with one power supply and redundant power supplies are optionally available. The power supplies are front serviceable. NOTE: A second WSM6 management module can be added to double the performance and provide redundancy of a SeverIron 450. A second WSM7 management module can be added to double the performance and provide redundancy of a SeverIron 450 PLUS. Figure 2.2 shows the front panel of a ServerIron 450 switch Foundry Networks, Inc. December 2006

13 Product Overview Figure 2.2 ServerIron 450 Switch ServerIron 850 Switch and 850 PLUS Switches The ServerIron 850 Family is a series of 8-slot, Layer 4 7 application switches that come pre-equipped with a WSM6 (ServerIron 850) or WSM7 (ServerIron 850 PLUS). The ServerIron 850 switch can be pre-equipped with up to seven JetCore line modules and support 10/100 Ethernet, Gigabit Ethernet (copper and fiber media), and 10 Gigabit Ethernet. The ServerIron 850 switch ships with one power supply and redundant power supplies are optionally available. The power supplies are front serviceable. NOTE: A second WSM6 management module can be added to double the performance and provide redundancy of a SeverIron 850. A second WSM7 management module can be added to double the performance and provide redundancy of a SeverIron 850 PLUS. Figure 2.3 shows the front panel of the ServerIron 850 switch. December Foundry Networks, Inc. 2-3

14 Foundry ServerIron Hardware Installation Guide Figure 2.3 ServerIron 850 Switch ServerIronGT C Series SSL Family The ServerIronGT C Series SSL Family are 3-slot IP application and Web optimization switches that come preequipped with a WSM6-SSL-1 (Web Switching Management module with integrated SSL capabilities) and a JetCore line module. The pre-equipped line modules can support 10/100 Ethernet and Gigabit Ethernet (copper and fiber media). 10 Gigabit Ethernet modules can be added as an option. The ServerIronGT C Series SSL Family features a modular, compact, and resilient design in 2U height. This switch ships with one power supply (rear pluggable) and redundant power supplies are optionally available. The ServerIronGT C Series SSL Family offers expandability and performance upgradability. You can add more line modules, or a second WSM6-SSL-1. The following ServerIronGT-C Series SSL Family base platforms are available: ServerIronGT CGx2 SSL ServerIronGT CGC16 SSL ServerIronGT C2404CF SSL ServerIronGT CGx2 SSL The ServerIronGT CGx2 SSL comes pre-equipped with two Gigabit Ethernet ports that support copper and fiber media options, and one WSM6-SSL-1 management module for integrated SSL acceleration. Figure 2.4 shows the front panel of the ServerIronGT CGx2 SSL Foundry Networks, Inc. December 2006

15 Product Overview Figure 2.4 ServerIronGT CGx2 SSL ServerIronGT CGC16 SSL The ServerIronGT CGC16 SSL comes pre-equipped with sixteen 100/1,000 Mbps Ethernet over copper ports, and one WSM6-SSL-1 management module for integrated SSL acceleration. Figure 2.5 shows the front panel of the ServerIronGT CGC16 SSL. Figure 2.5 ServerIronGT CGC16 SSL ServerIronGT C2404CF SSL The ServerIronGT C2404CF SSL comes pre-equipped with twenty-four 10/100 and four Gigabit Ethernet ports with copper and fiber media options, featuring one WSM6-SSL-1 management module for integrated SSL acceleration Figure 2.6 shows the front panel of the ServerIronGT C2404CF SSL. December Foundry Networks, Inc. 2-5

16 Foundry ServerIron Hardware Installation Guide Figure 2.6 ServerIronGT C2404CF SSL ServerIronGT C Series Family The ServerIronGT C Series are 3-slot IP application and Web optimization switches that come pre-equipped with a WSM6-1 (Web Switching Management Module) and a JetCore line module. The pre-equipped line modules can support 10/100 Ethernet and Gigabit Ethernet (copper and fiber media). 10 Gigabit Ethernet modules can be added as an option. The ServerIronGT C Series switches feature a modular, compact, and resilient design in 2U height. This switch ships with one power supply (rear pluggable) and redundant power supplies are optionally available. The ServerIronGT C Series switches offer expandability and performance upgradability. You can add more line modules, or a second WSM6-1. The following ServerIronGT-C Series base platforms are available: ServerIronGT CGx2 ServerIronGT CGC16 ServerIronGT C2404CF ServerIronGT CGx2 The ServerIronGT CGx2 comes pre-equipped with two Gigabit Ethernet ports that support copper and fiber media options, and one WSM6-1 management module. Figure 2.4 shows the front panel of the ServerIronGT CGx2. Figure 2.7 ServerIronGT CGx Foundry Networks, Inc. December 2006

17 Product Overview ServerIronGT CGC16 The ServerIronGT CGC16 comes pre-equipped with sixteen 100/1,000 Mbps Ethernet over copper ports, and one WSM6-1 management module. Figure 2.5 shows the front panel of the ServerIronGT CGC16. Figure 2.8 ServerIronGT CGC16 ServerIronGT C2404CF The ServerIronGT C2404CF comes pre-equipped with twenty-four 10/100 and four Gigabit Ethernet ports with copper and fiber media options, featuring one WSM6-1 management module. Figure 2.6 shows the front panel of the ServerIronGT C2404CF. Figure 2.9 ServerIronGT C2404CF ServerIron GTE SSL Family The ServerIron GTE SSL Family provides the following two switch models: SI-GT-E1BP-SSL SI-GT-E2BP-SSL These switches come pre-equipped with WSM6-SSL-1 or WSM6-SSL-2 with NO line cards. December Foundry Networks, Inc. 2-7

18 Foundry ServerIron Hardware Installation Guide ServerIronGT E Series Family The ServerIronGT E Series family comes pre-equipped, like the C Series, but features a four slot chassis and front-serviceable power supplies. These switches ship with one power supply and redundant power supplies are optionally available. The ServerIronGT E Series family provides the convenience of an appliance without sacrificing high availability, port expandability, and performance upgradability to accommodate growth. The ServerIronGT E Series family consists of two sub-series that meet a range of price, performance, and port configuration needs: ServerIronGT E Series ServerIronGT E Series Plus ServerIronGT E Series The ServerIronGT E Series includes the following products: ServerIronGT EGx2 ServerIronGT EGC16 ServerIronGT E2404CF ServerIronGT EGx2 The ServerIronGT EGx2 comes pre-equipped with an application switch management module (WSM6-1), featuring one dedicated processor for application traffic management, and a two port Gigabit Ethernet forwarding module (J-B2Gx). Figure 2.10 shows the front panel of the ServerIronGT EGx2. Figure 2.10 ServerIronGT EGx2 ServerIronGT EGC16 The ServerIronGT EGC16 comes pre-equipped with an application switch management module (WSM6-1), featuring one dedicated, processor for application traffic management, and a 16 port 100/1000 Mbps Ethernet over Copper forwarding module (J-B16GC). Figure 2.11 shows the front panel of the ServerIronGT EGC Foundry Networks, Inc. December 2006

19 Product Overview Figure 2.11 ServerIronGT EGC16 ServerIronGT E2404CF The ServerIronGT E2404CF comes pre-equipped with an application switch management module (WSM6-1), featuring one dedicated, processor for application traffic management, and a twenty-four port 10/100 Mbps and four Gigabit Ethernet port forwarding module (J-B2404CF). Figure 2.12 shows the front panel of the ServerIronGT E2404CF. Figure 2.12 ServerIronGT E2404CF ServerIronGT E Series Plus NOTE: The ServerIronGT E Series Plus systems deliver double the performance of the ServerIronGT E Series systems. The ServerIronGT E Series Plus includes the following products: ServerIronGT EGx4P ServerIronGT EGC16P ServerIronGT E2404CFP December Foundry Networks, Inc. 2-9

20 Foundry ServerIron Hardware Installation Guide ServerIronGT EGx4P The ServerIronGT EGx4P comes pre-equipped with an application switch management module (WSM6-2), featuring two dedicated processors for application traffic management, and a four Gigabit Ethernet port forwarding module (J-B4Gx). Figure 2.13 shows the front panel of the ServerIronGT EGx4P. Figure 2.13 ServerIronGT EGx4P ServerIronGT EGC16P The ServerIronGT E16P comes pre-equipped with an application switch management module (WSM6-2), featuring two dedicated processors for application traffic management, and a four Gigabit Ethernet port forwarding module (J-B16Gx). Figure 2.14 shows the front panel of the ServerIronGT EGC16P. Figure 2.14 ServerIronGT EGC16P Foundry Networks, Inc. December 2006

21 Product Overview ServerIronGT E2404CFP The ServerIronGT E10Gx2 comes pre-equipped with an application switch management module (WSM6-2), featuring two dedicated processors for application traffic management, and a twenty-four port 10/100 Mbps and four Gigabit Ethernet port forwarding module (J-B2404CF). Figure 2.18 shows the front panel of the ServerIronGT E2404CFP. Figure 2.15 ServerIronGT E2404CFP ServerIronGT 10 Gigabit Ethernet Systems The ServerIronGT E Series 10 Gigabit Ethernet system are available in three options: ServerIronGT C10Gx2P ServerIronGT E10Gx2P ServerIronGT E10Gx2 ServerIronGT C10Gx2P The ServerIronGT C10Gx2P comes pre-equipped with a WSM7 application switch management module, featuring three dedicated, high-performance, processors for application traffic management, and a two port 10 Gigabit Ethernet forwarding module (B10Gx2). Figure 2.16 shows the front panel of the ServerIronGT C10Gx2P. Figure 2.16 ServerIronGT C10Gx2P ServerIronGT C10Gx2P December Foundry Networks, Inc. 2-11

22 Foundry ServerIron Hardware Installation Guide ServerIronGT E10Gx2P The ServerIronGT E10Gx2P comes pre-equipped with a WSM7 application switch management module, featuring three dedicated, high-performance, processors for application traffic management, and a two port 10 Gigabit Ethernet forwarding module (B10Gx2). Figure 2.18 shows the front panel of the ServerIronGT E10Gx2P. Figure 2.17 ServerIronGT E10Gx2P ServerIron E10Gx2P ServerIronGT E10Gx2 The ServerIronGT E10Gx2 comes pre-equipped with an application switch management module (WSM6), featuring three dedicated, high-performance, processors for application traffic management, and a two port 10 Gigabit Ethernet forwarding module (B10Gx2). Figure 2.18 shows the front panel of the ServerIronGT E10Gx2. Figure 2.18 ServerIronGT E10Gx Foundry Networks, Inc. December 2006

23 Product Overview Web Switching Modules This section contains the following sections: Overview on page 2-13 WSM Management Modules on page 2-14 SSL Web Switching Modules on page 2-15 SSL Service Modules on page 2-16 Overview Based on Foundry multi-processor technology, web switching modules (WSMs) are supported on all of the ServerIron series switches with one management processor (MP) for device management and one, two, or three barrel processors (BPs) for application switched traffic. On the ServerIron 350, 450, E Series, and C Series and the WSM is located in the top slot of the device (slot 1). On the ServerIron 850, the WSM is located in the left-most slot of the device. This section contains the following sections: LEDs on page 2-13 Serial Management Interface on page 2-14 Reset Button on page 2-14 NOTE: Any system can be upgraded to a higher performance management module. NOTE: Dual management modules must be of the same type. NOTE: You cannot mix IronCore and JetCore modules in a single ServerIron device. NOTE: You can install up to two WSM6 modules in a device for double the performance and redundancy. However, using two WSM6 modules reduces the number of slots available for JetCore interface modules. With two WSM6 modules installed, both modules are active and the result is double the performance. NOTE: The WSM6-1 and WSM6-2 do not work with the IronCore line modules. LEDs You can determine the status of a WSM processor by observing its LEDs. Table 2.1 contains information on how to determine the status of each LED. Table 2.1: WSM LEDs LED Position State Status Active Upper LED to the left of the serial interface On Off The MP is active. The MP is not active. Power (Pwr) Lower LED to the left of the serial interface On Off The power status is good. The power status is not good. December Foundry Networks, Inc. 2-13

24 Foundry ServerIron Hardware Installation Guide Table 2.1: WSM LEDs (Continued) LED Position State Status Outbound Upper LED near the middle of the module Blinking The WSM CPU is transmitting data. Inbound Lower LED near the middle of the module Blinking The WSM CPU is receiving data. Serial Management Interface The serial management interface enables you to configure and manage the device using a third-party terminal emulation application on a directly connected PC. A straight-through EIA/TIA DB-9 serial cable (M/F) is shipped with the device. The serial management interface is located in the upper right corner of front panel, above the Gigabit Ethernet uplink ports. Reset Button The reset button allows you to restart the system without switching the power supplies off and on or using the CLI or Web management interface. The button is located to the right of the serial management interface and is recessed to prevent it from being pushed accidentally. A paper clip can make pushing the Reset button much easier. WSM Management Modules This section contains the following sections: WSM7 Management Module on page 2-14 WSM6 Management Module on page 2-14 WSM6-2 Management Module on page 2-15 WSM6-1 Management Module on page 2-15 WSM7 Management Module The WSM7 is a web switching management module with one MP for device management and three BPs with higher performance CPU per barrel for application switched traffic. Figure 2.20 shows the front panel of the WSM7. Figure 2.19 WSM7 Management Module BP LEDs MP LEDs Serial Port WSM 7 Subsystem Active Pwr Console Outbound TxAct Inbound RxAct Active Pwr Mgmt VII WSM6 Management Module The WSM6 is a web switching management module with one MP for device management and three BPs for application switched traffic. Figure 2.20 shows the front panel of the WSM Foundry Networks, Inc. December 2006

25 Product Overview Figure 2.20 WSM6 Management Module BP LEDs MP LEDs Serial Port WSM 6 Subsystem Active Pwr Console Outbound TxAct Inbound RxAct Active Pwr Mgmt VI WSM6-2 Management Module WSM6-2 is a web switching management module with one MP for device management and two BPs for application switched traffic. Figure 2.21 shows the front panel of the WSM6-2. Figure 2.21 WSM6-2 Management Module BP LEDs MP LEDs Serial Port WSM 6-2 Subsystem 1 2 Active Pwr Console Outbound TxAct Inbound RxAct Active Pwr Mgmt VI WSM6-1 Management Module WSM6-1 is a web switching management module with one MP for device management and one BP for application switched traffic. Figure 2.22 shows the front panel of the WSM6-1. Figure 2.22 WSM6-1 Management Module BP LEDs MP LEDs Serial Port WSM 6-1 Subsystem Outbound TxAct Inbound RxAct 1 Active Pwr Console Active Pwr Mgmt VI SSL Web Switching Modules This section contains the following sections: WSM6-SSL-1 Management Module on page 2-16 WSM6-SSL-2 Management Module on page 2-16 December Foundry Networks, Inc. 2-15

26 Foundry ServerIron Hardware Installation Guide WSM6-SSL-1 Management Module WSM6-SSL-1 is a SSL integrated management module with one MP for device management and one BP for application switched traffic and processing SSL. Figure 2.23 shows the front panel of the WSM6-SSL-1. Figure 2.23 WSM6-SSL-1 Management Module BP LEDs MP LEDs Serial Port WSM6-SSL-1 Subsystem Outbound TxAct Inbound RxAct 1 Active Pwr Console Active Pwr Mgmt VI w/ssl WSM6-SSL-2 Management Module WSM6-2 is a web switching management module with one MP for device management and two BPs for application switched traffic and processing SSL. Figure 2.24 shows the front panel of the WSM6-SSL-2. Figure 2.24 WSM6-SSL-2 Management Module BP LEDs MP LEDs Serial Port WSM6-SSL-2 Subsystem Outbound TxAct Inbound RxAct 1 2 Active Pwr Console Active Pwr Mgmt VI w/ssl SSL Service Modules The SSL service modules require a WSM6, WSM6-1, or WSM6-2 for management functions. NOTE: SSL service modules and WSM7 management modules are only compatible with release or later. This section contains the following sections: SRVC-SSL6-1 Service Module on page 2-16 SRVC-SSL6-2 Service Module on page 2-17 SRVC-SSL6-1 Service Module SRVC-SSL6-1 is a dedicated SSL service module with one BP for processing SSL. Figure 2.25 shows the front panel of the SRVC-SSL Foundry Networks, Inc. December 2006

27 Product Overview Figure 2.25 SRVC-SSL6-1 Service Module BP LEDs SRVC6-SSL-1 Subsystem Outbound TxAct Inbound RxAct 1 SRVC-SSL6-2 Service Module SRVC-SSL6-2 is a dedicated SSL service module with two BPs for processing SSL. Figure 2.26 shows the front panel of the SRVC-SSL6-2. Figure 2.26 SRVC-SSL6-2 Service Module BP LEDs SRVC6-SSL-2 Subsystem Outbound TxAct Inbound RxAct 1 2 JetCore Line Modules NOTE: code. All ServerIron modules and optics/gbics require Software Release S/R or a later version of The following JetCore line modules are available for the Foundry ServerIron Family switches: 10 Gigabit Ethernet Modules on page 2-17 Gigabit Ethernet Modules on page /1000Base-T Module on page Base-FX Module on page 2-19 J-B2404CF 24-Port 10/100Base-TX and 4-Port Combo Gigabit Ethernet Module on page /100 Mbps Ethernet Module on page 2-20 See also: LEDs on page 2-21 RJ-45 Pinouts on page Gigabit Ethernet Modules NOTE: Foundry 10 Gigabit Ethernet modules comply with the IEEE 802.3ae draft 3.3. They require optics. The B10Gx1 1-Port 10 Gigabit Ethernet module provides one 10-Gigabit Ethernet ports for XENPAK Multisource Agreement (MSA) optics. Figure 2.27 shows the front panel of the module. December Foundry Networks, Inc. 2-17

28 Foundry ServerIron Hardware Installation Guide Figure 2.27 B10Gx1 1-Port 10 Gigabit Ethernet Module J-B10Gx1 Link Active 1 The B10Gx2 2-Port 10 Gigabit Ethernet module provides two 10 Gigabit Ethernet ports for XENPAK Multisource Agreement (MSA) optics. The ServerIronGT E10Gx2 comes pre-equipped with this module. Figure 2.28 shows the front panel of the module. Figure 2.28 B10Gx2 2-Port 10 Gigabit Ethernet Module J-B10Gx2 Link Link Active 1 Active 2 10-Gigabit Ethernet Ports The 10-Gigabit Ethernet interfaces operate at full duplex. They use GBIC-like XENPAK Multisource Agreement (MSA) optics, which are hot-swappable, allowing you to change the optics without removing the module from the chassis. The following XENPAK optics are supported: 1310nm serial for single-mode fiber 1510nm serial for single-mode fiber For these optics, use the matching fiber type with an SC connector. For example, if you are using the 1310nm serial module for single-mode fiber, attach a 1310nm single-mode fiber cable that has an SC connector. For information about status LEDs, see LEDs on page Gigabit Ethernet Modules The J-B2Gx 2-Port 1000Base-X (mini-gbic) JetCore Line Module provides two Gigabit Ethernet ports. These ports can be equipped with fiber (1000Base-SX or 1000Base-LX) or copper (1000Base-TX) mini-gbic connectors. The ServerIronGT EGx2 comes pre-equipped with this module. Figure 2.29 shows the front panel of the module. Figure 2.29 J-B2Gx 2-Port 1000Base-X (mini-gbic) JetCore Line Module Link BxG 1 Active 2 The J-B4Gx 4-Port 1000Base-X (mini-gbic) JetCore Line Module provides four Gigabit Ethernet ports. These ports can be equipped with fiber (1000Base-SX or 1000Base-LX) or copper (1000Base-TX) mini-gbic connectors. The ServerIronGT EGx4 comes pre-equipped with this module. Figure 2.30 shows the front panel of the module. Figure 2.30 J-B4Gx 4-Port 1000Base-X (mini-gbic) JetCore Line Module Link Link BxG 1 Active 2 3 Active 4 The J-BxG 8-Port 1000Base-X (mini-gbic) JetCore Line Module provides eight 1000Base-X (mini-gbic) fiber ports. Figure 2.31 shows the front panel of the module Foundry Networks, Inc. December 2006

29 Product Overview Figure 2.31 J-BxG 8-Port 1000Base-X (mini-gbic) JetCore Line Module Link Link Link Link BxG 1 Active 2 3 Active 4 5 Active 6 7 Active 8 The J-B16Gx 16-Port 1000Base-X (mini-gbic) JetCore Line Module provides BaseSX or 1000BaseLX fiber ports. Figure 2.32 shows the front panel of the module. Figure 2.32 J-B16Gx 16-Port 1000Base-X (mini-gbic) JetCore Line Module J-F16Gx Link Link Link Link Link Link Link Link Link Link Link Link Link Link Link Link Active Actve Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Gigabit Ethernet Ports The ports can be equipped with fiber (1000Base-SX or 1000Base-LX) or copper (1000Base-TX) mini-gbic connectors. Each port has mini-gbic connectors for 1000 Base-SX or 1000 Base-LX fiber cables. For cabling information, see the "Connecting Network Devices" section in the "Installing the ServerIron" chapter of the Foundry ServerIron Installation and Configuration Guide. For information about status LEDs, see LEDs on page /1000Base-T Module The J-B16GC 16-Port 100/1000Base-T JetCore Line Module provides /1000 Ethernet ports (RJ-45). Figure 2.33 shows the front panel of this module. Figure 2.33 J-B16GC 16-Port 100/1000Base-T JetCore Line Module J-F16GC /1000 Ports Each 100/1000 port has its own RJ-45 connector for Category 5 (Cat5) cabling. You can connect each port to a 100 Mbps or 1000 Mbps segment. The ports automatically detect the speed of the network and configure themselves accordingly. You also can manually configure a port for 100 Mbps or 1000 Mbps. Use a crossover cable to connect to another Layer 2 Switch or Layer 3 Switch. A crossover cable swaps the wires so that the send signal on one port connects to the receive signal on the other port, and so on. Use a straight-through cable to connect to an end station or server. A straight-through cable does not swap the wires. For the pinout information and signalling, see RJ-45 Pinouts on page NOTE: The copper interfaces support auto-negotiation but do not support half-duplex mode. For information about status LEDs, see LEDs on page Base-FX Module The J-B24FX 24-Port 100Base-FX JetCore Line Module provides twenty four 100Base-FX fiber ports. Figure 2.34 shows the front panel of the module. December Foundry Networks, Inc. 2-19

30 Foundry ServerIron Hardware Installation Guide Figure 2.34 J-B24FX 100Base-FX JetCore Line Module J-B24FX Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act Lnk/Act 100BaseFX Fiber Ports The 100BaseFX ports are equipped with MT-RJ connectors for fiber-optic cable and operate at 100 Mbps in fullduplex mode. A single Integrated Packet Controller (IPC) manages the ports. Table 2.2 lists the kinds of media supported on the J-24FX module: Table 2.2: Supported Media for the J-24FX Module Media MM (Multimode) SR (Short Reach) IR (Intermediate Reach) Distance 2 km 15 km 40 km For information about status LEDs, see LEDs on page J-B2404CF 24-Port 10/100Base-TX and 4-Port Combo Gigabit Ethernet Module This module provides twenty four 10/100Base-TX ports and four Gigabit Ethernet ports (copper and fiber combo media). Figure 2.35 shows the front panel of the module. Figure 2.35 J-B2404CF 24-Port 10/100Base-TX and 4-Port Gigabit Ethernet Module J-F2404GMR4 J-B2404CF Link Link Link Link Active Active Active Active NOTE: This double-wide JetCore line module takes two slots in the chassis. For information about ports and status LEDs, see 10/100 Ports on page 2-21 or Gigabit Ethernet Ports on page 2-19, and LEDs on page /100 Mbps Ethernet Module The J-B48E-A 48-Port 10/100 JetCore Line Module provides 48 10/100 Ethernet ports. This double-wide module takes two slots in the chassis. Figure 2.36 shows the front panel of a JetCore 10/100 RJ-45 forwarding module. Figure 2.36 J-B48E-A 48-Port 10/100 JetCore Line Module J-B48E Foundry Networks, Inc. December 2006

31 Product Overview 10/100 Ports Each 10/100 port has its own RJ-45 connector. Each connector supports a 10/100 Ethernet network segment on Category 5 (Cat5) wire. The 10/100 ports use auto-sensing and auto-negotiating to determine the speed (10 Mbps or 100 Mbps) and mode (full-duplex or half-duplex) of the port at the other end of the link and adjust port speed accordingly. Use a crossover cable to connect to another Layer 2 Switch or Layer 3 Switch. A crossover cable swaps the wires so that the send signal on one port connects to the receive signal on the other port, and so on. Use a straight-through cable to connect to an end station or server. A straight-through cable does not swap the wires. For the pinout information, see Pin Assignment and Signalling for 10BaseTX and 100BaseTX Ports on page For information about status LEDs, see LEDs on page LEDs The LEDs listed in the tables provide status information for the supported JetCore Line Modules. All types of Foundry 10 Gigabit Ethernet modules use the same port LEDs. Table 2.3: LEDs for 10 Gigabit Ethernet, 100BaseFX, 1000BaseSX and 1000BaseT Ports LED Position State Meaning Link Top On Port is connected. Off No port connection exists. Activity Bottom On Traffic is being transmitted and received on that port. Off Blinking No traffic is being transmitted. Traffic is being transmitted and received on that port. Table 2.4: 100/1000 Port LEDs LED Position State Meaning Link/Activity Left On Port is connected. Off Blinking No port connection exists. Traffic is being transmitted and received on that port. FDX Right On The port is operating at full-duplex. Off The port is operating at half-duplex. Table 2.5: 10BaseT/100BaseTX LEDs LED Position State Meaning Link Left On Port is connected. Off Port is not connected. December Foundry Networks, Inc. 2-21

32 Foundry ServerIron Hardware Installation Guide Table 2.5: 10BaseT/100BaseTX LEDs LED Position State Meaning Activity Right Blinking Port is transmitting and receiving traffic. Off Port is not transmitting and receiving traffic. RJ-45 Pinouts Figure 2.37 shows the pin assignments and signalling for crossover connections. Figure 2.37 Crossover Pin Assignment and Signalling Pin Assignment 10BaseT Pin Number MDI-X ports 100BaseTX and 1000BaseT Pin Number MDI-X ports RD+ RD- TD+ Not used Not used TD- Not used Not used RD+ RD- TD+ CMT CMT TD- CMT CMT Power Consumption Matrix Use the Power Consumption Matrix to calculate the total power requirements, by adding up the watts for each individual piece of ServerIron hardware in your system. The power supplies have an 80% efficiency rate. So, for example: a C series chassis (50W), a WSM6 (125W), a J-B16GC (100W), and a J-B24FX (80W) would total 355 watts. 355 W * 1.2 (80%) = 426 watts 426 watts / 120 volts out of the power source = 3.5 amps Table 2.6 shows the power required in watts for the ServerIron platforms (empty chassis plus power supply), Web Switching Modules, and JetCore line modules. Table 2.6: Power Consumption Matrix ServerIron Hardware 3-slot Chassis 4-slot Chassis 8-slot Chassis WSM6-SSL-1 WSM6-SSL-2 SRVC-SSL6-1 Power Required (Watts) 50W 125W 125W 84W 119W 77W Foundry Networks, Inc. December 2006

33 Product Overview Table 2.6: Power Consumption Matrix ServerIron Hardware SRVC-SSL6-2 WSM6 WSM6-1 WSM6-2 WSM7 SI-4G B10Gx1 B10Gx2 J-B24FX J-B2404CF J-B48E J-BxG J-B16GC J-B2Gx J-B4Gx J-B16Gx Power Required (Watts) 105W 125W 85W 105W 125W 150W 110W 140W 80W 110W 110W 60W 100W 30W 40W 90W NOTE: The ServerIron 350 supports a 600 watt power supply. NOTE: The ServerIron 450 and 850 support a 500 watt power supply. NOTE: If the total watts is greater than the one power supply, you must add another power supply. Multiple power supplies share the load for the system. December Foundry Networks, Inc. 2-23

34 Foundry ServerIron Hardware Installation Guide Recommended Software Releases Table 2.7 shows the original software releases and minimum recommended software releases for the ServerIron chassis, management modules, and JetCore line modules. Table 2.7: Recommended Software Releases ServerIron Hardware Original Software Release Minimum Release Recommended SI-4G SI-4G-SSL WSM6-SSL WSM6-SSL SRVC-SSL SRVC-SSL slot Chassis WSM J-B2404CF WSM WSM J-B2Gx J-B4Gx B10Gx B10Gx slot Chassis slot Chassis WSM J-B48E-A J-BxG J-B16GC J-B16Gx NOTE: Bundles such as the GT-C and GT-E follow the higher version of their chassis/management module recommendation. NOTE: Foundry recommends running the latest patch release of every software revision Foundry Networks, Inc. December 2006

35 Product Overview Technical Specifications This section describes the technical and physical specifications for the ServerIron family switches. Load Balancing Methods Least connections Response time Response time + least connections Round robin Weighted distribution Bandwidth and Weighted Bandwidth Layer 2 Switching Capabilities 32,000 MAC addresses 802.1d Spanning Tree Protocol 802.1p prioritization Policy-based VLANs Port-based VLANs Layer 3 protocol VLANs Layer 3 protocol and subnet VLANs 802.1q VLAN tagging Protocol Support TCP UDP SSL FTP Telnet SMTP HTTP (1.0 and 1.1) IMAP4 LDAP NNTP POP3 DNS BootP TFTP SNMP VRRP/VRRPe IPSec December Foundry Networks, Inc. 2-25

36 Foundry ServerIron Hardware Installation Guide RADIUS VoIP SIP Windows Terminal Server (WTS) Standards Compliance 802.3,10BaseT 802.3u 100BaseTX,100BaseFX 802.3z 1000BaseSX 802.3z 1000BaseLX 802.1q VLAN Tagging 802.1d Bridging 802.1w RSTP 802.3ad Link Aggregation Ethernet Like MIB Repeater MIB Ethernet Interface MIB SNMP (V2C) SNMP MIB II Network Management Integrated Command Line Interface SSH Web based GUI Telnet SNMP RMON IronView Network Manager (INM) HP OpenView Safety Agency Approvals EN 60950/EN 60825/IEC 60950, Information Technology Equipment Safety Part 1: General Requirements CAN/CSA 22.2 No /UL60950, Information Technology Equipment Safety Part 1: General Requirements CE Mark Low Voltage Directive 73/23/EEC Electromagnetic Approvals FCC Class A ICES-003 Class A (Canada) EN Class A Foundry Networks, Inc. December 2006

37 Product Overview CISPR22 Class A VCCI Class A CE Mark EMC Directive 89/336/EEC Immunity Generic: EN , EN55024 ESD: IEC ; 4 kv CD, 8 kv AD Radiated: IEC ; 3 V/m EFT/Burst: IEC ; 1.0 kv (power line), 0.5 kv (signal line) Conducted: IEC ; 3 V Environmental Operating Temperature: 0 C to 40 C (32 F to 104 F) Relative Humidity: 5 to 90%,@ 40 C (104 F), non-condensing Operating Altitude: 6,000 ft (2,000 m) maximum Storage Temperature: -25 ºC to 70 ºC (-9 ºF to 158 F) Storage Altitude: 15,000 ft (4,500 m maximum Storage Humidity: 95% maximum relative humidity, non-condensing Mounting Options 19" Universal EIA (Telco) Rack Tabletop December Foundry Networks, Inc. 2-27

38 Foundry ServerIron Hardware Installation Guide Foundry Networks, Inc. December 2006

39 Chapter 3 Installing the ServerIron This chapter describes how to install Foundry ServerIrons and attach them to your network. WARNING: The procedures in this manual are for qualified service personnel. Unpacking a System The Foundry ServerIron ships with all the following items. Please review the list below and verify the contents. If any items are missing, contact the place of purchase. Package Contents Foundry ServerIron 115V AC power cable Rack mount brackets and mounting screws CD-ROM containing software and user documentation (including this guide) Warranty card General Requirements To manage the system, you need the following items for serial connection to the ServerIron: A management station, such as a PC running a terminal emulation application. A straight-through EIA/TIA DB-9 serial cable (F/F). The serial cable can be ordered separately from Foundry Networks (part number CC). If you prefer to build your own cable, see the pinout information in Attaching a PC or Terminal on page 3-5. You use the serial connection to perform basic configuration tasks including assigning a management IP address and network mask to the system. This information is required for managing the system using the Web management interface or IronView or using the CLI through Telnet. Summary of Installation Procedures Follow the steps below to install your ServerIron. Details for each step are provided later in this chapter. 1. Ensure that the physical environment that will host the device has the proper cabling and ventilation. See Preparing the Installation Site on page 3-3. December Foundry Networks, Inc. 3-1

40 Foundry ServerIron Hardware Installation Guide 2. Optionally install or remove redundant power supplies. See Installing or Removing DC Power Supplies (for 4- Slot Chassis Devices) on page Verify that the system and module LEDs are registering the proper LED state after power-on of the system. See Verifying Proper Operation on page A terminal or PC serial port connection is all that is required to support configuration on the ServerIron. See Attaching a PC or Terminal on page Before attaching equipment to the device, you need to assign an interface IP address for the sub-net on which the device will be located. Initial IP address assignment is done using the CLI with a direct serial connection. Subsequent IP address assignments can be performed using the Web management interface. See Assigning IP Addresses on page 3-7. NOTE: The ServerIron allows you to configure up to four additional IP sub-net addresses. Depending on the network topology, you might need to configure additional addresses. 6. Foundry devices can be installed on a desktop or in an equipment rack. See Mounting the ServerIron in an Equipment Rack on page Once the device is physically installed, plug the device into a nearby power source that adheres to the regulatory requirements outlined in this guide. See Powering On the ServerIron on page Once you power on the device and assign IP addresses, the system is ready to accept network equipment. See Connecting Network Devices on page Test IP connectivity to other devices by pinging them. See Testing Connectivity on page Configure a system name, contact, and location. 11. Continue configuring the device using the CLI or the Web management interface. Secure access to the device. See Foundry Security Guide. Installation Precautions Follow these precautions when installing the ServerIron: General Precautions WARNING: Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over. WARNING: Mount the devices you install in a rack or cabinet as low as possible, placing the heaviest device at the bottom and progressively placing lighter devices above. WARNING: Disconnect the power cord from all power sources to completely remove power from the device. CAUTION: Do not install the device in an environment where the operating ambient temperature might exceed 40 o C (104 o F). CAUTION: Make sure the air flow around the front, sides, and back of the device is not restricted Foundry Networks, Inc. December 2006

41 Installing the ServerIron Power Precautions CAUTION: Make sure that the power source circuits are properly grounded, then use the power cord supplied with the device to connect it to the power source. If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device. CAUTION: Ensure that the device does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add the ampere ratings of all devices installed on the same circuit as the device. Compare this total with the rating limit for the circuit. The maximum ampere ratings are usually printed on the devices near the AC power connectors. CAUTION: Use separate branch circuits for the power. This provides redundancy in case one of the circuits fails. CAUTION: All devices with DC power supplies are intended for installation in restricted access areas only. A restricted access area is where access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location. CAUTION: For the DC input circuit to a 4-slot or 8-slot Chassis device (DC power supply part number RPS3DC), make sure there is a Listed 20 amp circuit breaker, minimum 48Vdc, double pole, on the input to the power supply. The input wiring for connection to the product should be Listed copper wire, 14 AWG, marked VW- 1, and rated minimum 90 C. CAUTION: For DC power supplies in 4-slot or 8-slot Chassis devices (part number RPS3DC), use a grounding wire of at least 14 American Wire Gauge (AWG). CAUTION: For the DC input circuit to the system (DC power supply part number SI350-DC), make sure there is a 30 amp circuit breaker, minimum -48Vdc, double pole, on the input to the terminal block. The input wiring for connection to the product should be copper wire, 10 AWG, marked VW-1, and rated minimum 90 degrees celcius. CAUTION: For a DC system (DC power supply part number SI350-DC), use a grounding wire of at least 10 American Wire Gauge (AWG). The 10 AWG wire should be attached to an agency-approved crimp connector, crimped with the proper tool. Preparing the Installation Site Cabling Infrastructure Ensure that the proper cabling is installed in the site. See Connecting Network Devices on page 3-11 for a summary of supported cabling types and their specifications. Installation Location Before installing the device, plan its location and orientation relative to other devices and equipment. Allow at least 3" of space at the front of the device for the twisted-pair, fiber-optic, and power cabling. Also, allow a minimum of 3" of space between the sides and the back of the device and walls or other obstructions. December Foundry Networks, Inc. 3-3

42 Foundry ServerIron Hardware Installation Guide Installing or Removing DC Power Supplies (for 4-Slot Chassis Devices) Use the following procedures for DC power supplies in 4-slot Chassis devices. Use power supply model RPS3DC for 4-slot Chassis devices. Figure 3.1 DC power supply for 4-slot or 8-slot Chassis device (part number RPS3DC) Installing a DC Power Supply 1. Prepare the positive, negative, and ground wires by stripping about 1/4" of insulation off the end of each one. (Use at least 14 AWG wire.) 2. Loosen the three screws used to hold the wires in the connector. These are the wires under the following markings: NOTE: If you cannot easily reach the screws and wire openings due to the connector guard, remove the connector guard from the power supply. The guard is fastened to the supply by two Phillips-head screws and is mounted over the connector. 3. Slip the ground wire into the opening under the marking until the wire is fully in place, then tighten the screw to hold the wire in place. 4. Repeat for the negative ( ) and positive (+) wires. 5. Pull gently on each wire to make sure they are securely fastened in the connector. 6. Re-attach the connector guard over the connector. 7. Insert the power supply into the chassis. Seat the supply firmly so that the faceplate of the supply is flush with the chassis surface. WARNING: Metal edges on the power supply may be sharp. 8. Tighten the two thumb screws to secure the power supply to the chassis. 9. After the power supply is properly inserted, connect the power source to the wires to activate the circuit. Removing a DC Power Supply 1. Turn off the DC power source or disconnect it from the power supply. 2. Loosen the three screws used to hold the wires in the connector, then pull out the wires Foundry Networks, Inc. December 2006

43 Installing the ServerIron NOTE: If you cannot easily reach the screws and wire openings due to the connector guard, remove the connector guard from the power supply. The guard is fastened to the supply by two Phillips-head screws and is mounted over the connector. If you remove the connector guard, re-attach it once you are finished removing the wires to prevent the guard from being lost. 3. Loosen the two thumb screws that secure the power supply to the chassis. 4. Pull the power supply completely out of the chassis. WARNING: Metal edges on the power supply may be sharp. Verifying Proper Operation Before mounting the device in its network location, verify that the device is working properly by plugging it into a power source and verifying that it passes its self test. If your device has more than one power supply installed, repeat the following stps for each power supply. 1. Connect the power cord supplied with the ServerIron to the power connector on the power supply at the rear of the device. 2. Insert the other end into a properly grounded electrical outlet. NOTE: The devices do not have power switches. They power on when you connect a power cord to the device and to a power source. If your installation requires a different power cord than that supplied with the device, make sure you obtain a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your assurance that the power cord can be used safely with the device. 3. Check the LEDs on the front of the device. When the system is first powered on, the lights simultaneously light as the system goes through system and module diagnostics. After the initial diagnostics are complete, none of the port LEDs light up until a cable is connected. For more details on specific LED conditions after system start-up, see LEDs on page Attaching a PC or Terminal Foundry devices do not have an IP address when shipped from the factory. You need to assign an IP address using the CLI. To assign an IP address, you must have access to the Command Line Interface (CLI). The CLI is a text-based interface that can be accessed through a direct serial connection to the device and through Telnet connections. The CLI is described in detail in the Foundry ServerIron Command Line Interface Reference. You can attach a serial cable to the Console port. After you assign an IP address, you also can access the system through Telnet and through the Web management interface. To attach to a management station using the serial port: 1. Connect a PC or terminal to the serial port of the ServerIron using a straight-through cable. The serial port has a male DB-9 connector. NOTE: You need to run a terminal emulation program on the PC. 2. Open the terminal emulation program and set the session parameters as follows: Baud: 9600 bps Data bits: 8 Parity: None December Foundry Networks, Inc. 3-5

44 Foundry ServerIron Hardware Installation Guide Stop bits: 1 Flow control: None When you establish the serial connection to the system, press Enter to display the following CLI prompt in the terminal emulation window: ServerIron> If you see this prompt, you are now connected to the CLI and can proceed to Assigning IP Addresses on page 3-7. NOTE: If you are configuring a Foundry switch that you have upgraded with ServerIron code, the command prompt might be different. You can customize the prompt by changing the system name. If you do not see one of these prompts: 1. Make sure the cable is securely connected to your PC and to the Foundry system. 2. Check the settings in your terminal emulation program. In addition to the session settings listed above, make sure the terminal emulation session is running on the same serial port you attached to the Foundry system. The EIA/TIA 232 serial communication port serves as a connection point for management by a PC or SNMP workstation. The ServerIron comes with a standard male DB-9 connector, shown in Figure 3.2. Figure 3.2 Serial port pin and signalling details Pin Assignment Pin Number Switch Signal 1 DB-9 male Reserved TXD (output) RXD (input) Reserved GND Reserved CTS (input) RTS (output) Reserved Most PC serial ports also require a cable with a female DB-9 connector. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between a Foundry switch or router and a PC or terminal are shown in Figure 3.3. NOTE: As indicated in Figure 3.2 and Figure 3.3, some of the wires should not be connected. If you do connect the wires that are labeled Reserved, you might get unexpected results with some terminals Foundry Networks, Inc. December 2006

45 Installing the ServerIron Figure 3.3 Serial port pin assignment showing cable connection options to a terminal or PC DB-9 to DB-9 Female Switch Terminal or PC DB-9 to DB-25 Female Switch Terminal or PC 1 Reserved 1 1 Reserved Reserved 4 4 Reserved Reserved 6 6 Reserved Reserved 9 9 Reserved 22 Assigning IP Addresses Foundry devices are not pre-configured at the factory with IP addresses. You must assign an IP address using the serial connection to the CLI before you can manage the system using the other management interfaces. Foundry devices support both classical IP network masks (Class A, B, and C sub-net masks, and so on) and prefix masks. To enter a classical network mask, enter the mask in IP address format. For example, enter " " for an IP address with a Class-C sub-net mask. To enter a network mask using prefix addressing, enter a forward slash ( / ) and the number of bits in the mask immediately after the IP address. For example, enter " /24" for an IP address that has a network mask with 24 significant ("mask") bits. By default, the CLI displays network masks in classical IP address format (example: ). You can change the display to prefix-addressing format. See the Configuring IP and IP/RIP chapter in the Foundry Switch and Router Installation and Basic Configuration Guide. NOTE: If your network uses a BootStrap Protocol (BootP) server or a Dynamic Host Configuration Protocol (DHCP) server, you can allow the Foundry device to obtain IP information from the server. To assign a management IP Address to a ServerIron: 1. At the opening CLI prompt, enter enable. ServerIron> enable 2. Enter the following command at the Privileged EXEC level prompt (for example, ServerIron#), then press Enter. This command erases the factory test configuration if still present: ServerIron# erase startup-config NOTE: Use this step only for new systems. If you enter this command on a system you have already configured, the command erases the configuration. If you accidentally do erase the configuration on a configured system, enter the write memory command to save the running configuration to the startup-config file. 3. Access the configuration level of the CLI by entering the following command: ServerIron# configure terminal ServerIron(config)# 4. Set the IP and mask addresses. December Foundry Networks, Inc. 3-7

46 Foundry ServerIron Hardware Installation Guide ServerIron(config)# ip address Set a default gateway address for the switch. ServerIron(config)# ip default-gateway Syntax: enable [<password>] Syntax: configure terminal Syntax: ip address <ip-addr> <ip-mask> or Syntax: ip address <ip-addr>/<mask-bits> Syntax: ip default-gateway <ip-addr> NOTE: If you plan to deploy the ServerIron in a multinetted environment, you can add up to four additional source IP addresses. The source IP addresses allow the ServerIron and the real servers, remote access server (RAS), and border access router (BAR) to be on different sub-nets. Mounting the ServerIron in an Equipment Rack This section describes how to install the ServerIron on a desktop or in an equipment rack. This section contains the following sections: Desktop Installation for a ServerIron Chassis on page 3-8 Rack Mount Installation for a ServerIron 4-Slot Chassis on page 3-8 Rack Mount Installation for a ServerIron 3-Slot Chassis on page 3-9 WARNING: Make sure the rack or cabinet housing the ServerIron is adequately secured to prevent it from becoming unstable or falling over. WARNING: Mount the devices you install in a rack or cabinet as low as possible, placing the heaviest device at the bottom and progressively placing lighter devices above. NOTE: If you are installing a ServerIron Chassis device, see the Installing a Foundry Layer 2 Switch or Layer 3 Switch chapter in the Foundry Switch and Router Installation and Basic Configuration Guide for installation instructions for chassis devices. Desktop Installation for a ServerIron Chassis 1. Set the ServerIron on a flat desktop, table, or shelf. Make sure that adequate ventilation is provided for the system a 3-inch clearance is recommended on each side. 2. Go to Testing Connectivity on page Rack Mount Installation for a ServerIron 4-Slot Chassis NOTE: You need a #2 Phillips-head screwdriver for installation. 1. Remove the rack mount kit from the shipping carton. The kit contains two L-shaped mounting brackets and mounting screws. 2. Attach the mounting brackets to the sides of the ServerIron as illustrated in Figure Attach the ServerIron in the rack as illustrated in Figure Foundry Networks, Inc. December 2006

47 Installing the ServerIron 4. Proceed to Testing Connectivity on page Figure 3.4 Installing a ServerIron in an equipment rack Rack Mount Installation for a ServerIron 3-Slot Chassis To get started, you need a #2 Phillips-head screwdriver and the rack mount kit, which was shipped with the switch. The kit contains sixteen screws (eight screws per side) to attach the rackmount brackets to the chassis unit), four screws (two per side) to mount the chassis unit to the rack, and two "long eared" mounting brackets. NOTE: You can torque the screws from 6 to 8 inch-lbs. NOTE: The product has been tested for dual RPS8 and additional weight. To mount the brackets on the switch, follow these steps: 1. Remove the rack mount kit from the shipping carton. 2. Align the brackets with the screw holes on the switch as shown in Figure Attach the mounting brackets to the sides of the ServerIron with the sixteen screws. December Foundry Networks, Inc. 3-9

48 Foundry ServerIron Hardware Installation Guide Figure 3.5 Installing the Mounting Brackets on a ServerIron 3-Slot Chassis To install the switch in the equipment rack, follow these steps: 1. Raise the switch to the level of the equipment rack. 2. Align the brackets with the screw holes on the equipment rack as shown in Figure Attach the mounting brackets to the sides of the ServerIron with the four screws. Figure 3.6 Installing a ServerIron 3-Slot Chassis in an Equipment Rack Foundry Networks, Inc. December 2006

49 Installing the ServerIron Powering On the ServerIron After you complete the physical installation of the ServerIron, you can power on the system. 1. Remove the power cord from the shipping package. 2. Attach the AC power cable to the AC connector on the rear panel. 3. Insert the power cable plug into a 115V/120V outlet. NOTE: Foundry devices are designed to provide uninterrupted service even when you insert or remove modules. Therefore, the systems do not have separate on/off power switches. To turn the system off, simply unplug the power cord(s). The socket should be installed near the equipment and should be easily accessible. If the outlet is not rated 115/120V, stop and get the appropriate cable for the outlet. Connecting Network Devices Foundry devices can support connections to other vendors routers, switches, and hubs as well other Foundry switches and routers. The 8-port, 16-port, and 24-port ServerIrons all use 10BaseT/100BaseTX ports with RJ-45 jacks for standard unshielded twisted pair (UTP/Category 5) cable connections. If you have the optional gigabit uplink, these devices support the following types of interfaces: 10BaseT/100BaseTX ports come with RJ45 jacks for standard unshielded twisted pair (UTP/Category 5) cable connections. 100BaseFX ports come equipped with SC(MMF) connectors. 1000BaseSX ports come equipped with SC(MMF) connectors. 1000BaseLX ports come equipped with SC(SMF) connectors. 1000BaseLH ports come equipped with SC(SMF) connectors. Figure 3.7 Pin Assignment and Signalling for 10BaseTX and 100BaseTX Ports 10BaseT 100BaseTX and 1000BaseT Pin Assignment Pin Number MDI-X ports Pin Number MDI-X ports RD+ RD- TD+ Not used Not used TD- Not used Not used RD+ RD- TD+ CMT CMT TD- CMT CMT December Foundry Networks, Inc. 3-11

50 Foundry ServerIron Hardware Installation Guide Cable Length Table 2.1 Cable length summary table Fiber Type Core Diameter (microns) Modal Bandwidth (MHz*km) Minimum Range (meters) 1000Base-SX MMF a 100BaseTX: Cable length should not exceed 100 meters in keeping with the IEEE standard. 100BaseFX: Cable length should not exceed 2 kilometers. 1000BaseSX: Cable length should not exceed 550 meters when operating with multi-mode cabling. 1000BaseLX: MMF b MMF MMF c 1000Base-LX MMF MMF MMF SMF 9 n/a a. The TIA 568 building wiring standard specifies 160/500 MHz*km MMF (Multi-mode Fiber). b. The international ISO/IEC building wiring standard specifies 200/500 MHz*km MMF. c. The ANSI Fibre Channel specification specifies 500/500 MHz*km 50 micron MMF and 500/500 MHz*km fiber has been proposed for addition to ISO/IEC Cable length of meters is supported on 62.5 µm multi-mode fiber (MMF) cabling. Cable length of meters is supported on 50 µm multi-mode fiber (MMF) cabling. Cable length of meters is supported on 9 µm single-mode fiber (SMF) cabling. 1000BaseLH: Cable length should not exceed 70 kilometers. NOTE: Cable installation and network configuration will affect overall transmission capability. The numbers provided above represent the accepted recommendations of the various standards. For network-specific recommendations, consult your local Foundry reseller system engineer. Connecting to Ethernet or Fast Ethernet Hubs For UTP connections to Ethernet or Fast Ethernet hubs, a 10/100 Mbps switch, or another switch or router, a crossover cable is required (Figure 3.8). If the hub is equipped with an uplink port, it will require a straight-through cable rather than a crossover cable Foundry Networks, Inc. December 2006

51 Installing the ServerIron Figure 3.8 UTP crossover cable UTP Crossover Cable 10/100BaseTX unused unused unused 5 5 unused 6 6 unused 7 7 unused unused 8 8 unused Connecting to Workstations, Servers, or Routers Straight-through UTP cabling is required for direct UTP attachment to workstations, servers, or routers using network interface cards (NICs). Fiber cabling with SC connectors is required for direct attachment to Gigabit NICs or switches and routers. Troubleshooting Network Connections For the indicated port, verify that both ends of the cabling (at the ServerIron and at the connected device) are snug. Verify that the ServerIron and the connected device are both powered on and operating correctly. Verify that you have used the correct cable type for the connection: For twisted-pair connections to an end node, use straight-through cabling. For fiber-optic connections, verify that the transmit port on the ServerIron is connected to the receive port on the connected device, and that the receive port on the ServerIron is connected to the transmit port on the connected device. Verify that the port has not been disabled through a configuration change. You can use the CLI. If you have configured an IP address on the device, you also can use the Web management interface. If the procedures above do not resolve the problem, try using a different port or a different cable. Testing Connectivity After you install the network cables, you can test network connectivity to other devices by pinging those devices. You also can perform trace routes. Pinging an IP Address To verify that a ServerIron can reach another device through the network, enter a command such as the following at any level of the CLI: ServerIron> ping Syntax: ping <ip-addr> <hostname> [count <num>] [timeout <msec>] [ttl <num>] [size <byte>] [no-fragment] [quiet] [verify] [data <1 4 byte hex>] [brief] December Foundry Networks, Inc. 3-13

52 Foundry ServerIron Hardware Installation Guide Tracing a Route To determine the path through which a Foundry device can reach another device, enter a command such as the following at any level of the CLI on the Foundry device: ServerIron> traceroute Syntax: traceroute <host-ip-addr> [minttl <value>] [maxttl <value>] [timeout <value>] [numeric] Foundry Networks, Inc. December 2006

53 Chapter 4 ServerIron 4G Series This chapter describes the ServerIron 4G Series. It contains the following major sections: Product Overview on page 4-1 Installing ServerIron 4G Series on page 4-6 Connecting ServerIron 4G Series on page 4-17 Managing ServerIron 4G Series on page 4-22 Technical Specifications on page 4-24 Cautions and Warnings on page 4-30 Product Overview This section describes an overview of the ServerIron 4G Series. It contains the following sections: ServerIron 4G Series on page 4-1 Common Features on page 4-2 Common Components on page 4-2 ServerIron 4G Series The ServerIron 4G Series introduces two new stackable switches: ServerIron 4G and ServerIron 4G-SSL. Figure 4.1 shows a photo of the ServerIron 4G. Figure 4.1 ServerIron 4G December Foundry Networks, Inc. 4-1

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20 Index Numerics 10/100 mode 8-27 1000BaseLx 7-10 1000BaseSx 7-10 1000BaseT 7-10 100BaseFx 7-10 100BaseFx Ports 7-10 100BaseTx 7-10 10BaseT 7-10 802.3x Gigabit negotiation 8-29 9304M Routing Switch 2-9 9308M

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Foundry FastIron Compact Switch Hardware Installation Guide

Foundry FastIron Compact Switch Hardware Installation Guide Foundry FastIron Compact Switch Hardware Installation Guide FastIron Edge Switch FastIro Edge Switch X Series FastIron Workgroup Switch X Series FES 04.1.00 FSX 05.0.00 Release Date: December 16, 2008

More information

Foundry BigIron RX Series Installation Guide

Foundry BigIron RX Series Installation Guide Foundry BigIron RX Series Installation Guide 2100 Gold Street P.O. Box 649100 San Jose, CA 95164-9100 Tel 408.586.1700 Fax 408.586.1900 January 2006 Copyright 2006 Foundry Networks, Inc. All rights reserved.

More information

Foundry FastIron Stackable Hardware Installation Guide

Foundry FastIron Stackable Hardware Installation Guide Foundry FastIron Stackable Hardware Installation Guide FastIron Edge Switch FastIron Edge Switch X-Series FastIron Workgroup Switch X-Series 2100 Gold Street P.O. Box 649100 San Jose, CA 95164-9100 Tel

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP MS400870M 24 Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP User's Guide. Ver.:0.91 1 CE Mark Warning This is a Class A product. In a domestic environment, this product may cause radio interference

More information

Overview. Switch Features CHAPTER

Overview. Switch Features CHAPTER CHAPTER 1 Overview The 2900 XL series switches are workgroup Ethernet switches that supply autosensing 10BaseT or 100BaseT connections on all ports. Expansion slots on Catalyst 2912MF XL and 2924M XL switches

More information

High Availability Application and Traffic Management Switches

High Availability Application and Traffic Management Switches ServerIronGT E-Series ServerIronGT E-Series Plus ServerIronGT E-Series 10 Gigabit High Availability Application and Traffic Management Switches Features t Purpose-built high-availability and high-performance

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide EL1142 Series IEC 61850 / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter User s Guide All Rights Reserved Dissemination or reproduction of this document, or its contents,

More information

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual Fourth Edition, DEC, 2007 www.korenix.com Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User

More information

XPress-Pro SW User Guide

XPress-Pro SW User Guide XPress-Pro SW 92000 User Guide Part Number 900-505 Revision A May 2007 Copyright & Trademark Contacts 2005, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced

More information

Chapter 7 Hardware Overview

Chapter 7 Hardware Overview Chapter 7 Hardware Overview This chapter provides a hardware overview of the HP 9308M, HP 930M, and HP 6308M-SX routing switches and the HP 6208M-SX switch. For information about specific hardware standards

More information

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER

Product Overview. Switch Features. Catalyst 4503 Switch Features CHAPTER CHAPTER This chapter provides an overview of the features and components of the Catalyst 4500 series switches. The Catalyst 4500 series switches are the Catalyst 4503 switch, the Catalyst 4506 switch,

More information

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports INDEX Numerics 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 10/100 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 1000BASE-T ports C-6 100BASE-FX ports cable lengths 2-4, B-6

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

Product Overview. Features CHAPTER

Product Overview. Features CHAPTER CHAPTER 1 This chapter provides these topics that describe the Catalyst 2900 series XL switches, hereafter referred to as the switches. Switch features, including management options Descriptions of the

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability,

More information

ProCurve Switch 1400 Series

ProCurve Switch 1400 Series The ProCurve Switch 1400 series provides plug-and-play simplicity for high-bandwidth connectivity. The Switch 1400 series consists of two unmanaged switches. The ProCurve Switch 1400-24G is a 24-port 10/100/1000

More information

KFC-200. Installation Guide

KFC-200. Installation Guide KFC-200 10/100BASE-TX to 100BASE-FX Media Converters Installation Guide DOC.121221-1- (C) 2011-2012 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or

More information

SERVERIRONGT E-SERIES

SERVERIRONGT E-SERIES SERVERIRONGT E-SERIES ServerIronGT E10Gx2 ServerIronGT EGx4 ServerIronGT EGx2 High Availability Application and Traffic Management Switches Features t Purpose-built high-availability and high-performance

More information

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch User s Guide FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the

More information

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v IES-0823 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail User Manual v1.00-1206 Preface A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch

More information

Chapter 6 Hardware Overview

Chapter 6 Hardware Overview Chapter 6 Hardware Overview This chapter provides a hardware overview of the HP ProCurve 9308M, 9304M, and 6308M-SX routing switches, and the HP ProCurve 6208M-SX switch. For information about specific

More information

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual 8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a

More information

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services BLACKBOX NETWORK SERVICES one source for worldwide infrastructure services 24 Port 10/100Mbps plus 2 Gigabit TX/FX Auto-MDIX Modular Gigabit Ethernet Switch User s Manual FCC Warning This device has been

More information

XPress-Pro SW User Guide

XPress-Pro SW User Guide XPress-Pro SW 52000 User Guide Part Number 900-509 Revision A May 2007 Copyright & Trademark Contacts 2005, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced

More information

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Product names mentioned in this manual may be trademarks or registered trademarks of those products. FCC Statement The FCC (Federal Communications Commission) restricts the amount of radio frequency emission and radiation coming from computer equipment. The equipment introduced in this manual has been

More information

Quick Start Guide. Physical Description. The Port Status LEDs

Quick Start Guide. Physical Description. The Port Status LEDs Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. Capable of operating at temperature extremes of -40 C to +75 C, this is the switch of choice

More information

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

More information

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual 1 10/100TX + 1 100FX w/ 1 PoE Injector Industrial Switch User Manual CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user

More information

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web:   ; User s Manual Management Converter Chassis Model No.: SP1386 / SP1387 World Wide Web: www.micronet.com.tw ; www.micronet.info Table of Content 1. INTRODUCTION... 2 1.1 PACKAGE CONTENT... 2 1.2 KEY FEATURES...

More information

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX KGC-352 Series Installation Guide DOC.070820-KGC-352-1- (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation

More information

Chassis-based Media Converters

Chassis-based Media Converters Media Converters with Individual Metal Case Housing. DMC-615SC DMC-1002 Management Module DMC-1000 Chassis Chassis-based Media Converters System Overview The Chassis-based Media Converters include a number

More information

FSM-510G Series Ethernet Management Switch Quick Start Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide FSM-510G Series Ethernet Management Switch Quick Start Guide Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed switches are easily

More information

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial 3-Port Fast Ethernet Media Converter Switches Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation

More information

6GK6023-0AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

6GK6023-0AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed 6GK6023-0AS1.-... RUGGEDCOM RSG2300NC Technical Data Product-type designation

More information

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide

TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide TE100-DX16R/DX24R/DX32R 16/24/32 Ports Ethernet/Fast Ethernet Dual-Speed Stackable Hubs User s Guide Rev. 01 (JULY, 1998) 505-0100-004 Printed In Taiwan RECYCLABLE Dual-Speed Stackable Hubs User s Guide

More information

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide January 2005 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 A050130380 The information

More information

Industrial Ethernet Switch

Industrial Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the hardened Ethernet Switch. Capable of operating at temperature extremes of -10 C to +60 C, this is the switch of choice for

More information

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches Product Overview The Cisco Catalyst 2950 Series of fixed configuration, wire-speed Fast Ethernet desktop switches delivers premium

More information

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

FVT Slot Media Converter Chassis w/ Redundant Power User Manual FVT-4000 10-Slot Media Converter Chassis w/ Redundant Power User Manual Ver. 1.00-0609 Table of Contents 1. INTRODUCTION... 1 1.1. FEATURES... 1 1.2. PACKAGE CONTENTS... 2 2. HARDWARE DESCRIPTION... 3

More information

Industrial Gigabit Managed Ethernet Switch

Industrial Gigabit Managed Ethernet Switch HMG-828 HMG-828E Industrial Gigabit Managed Ethernet Switch Features High Performance Network Switching Technology Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3X, IEEE 802.1p, IEEE 802.1q, IEEE 802.1d,

More information

Modular 8-Port Mid-span Power over Ethernet Injector

Modular 8-Port Mid-span Power over Ethernet Injector Modular 8-Port Mid-span Power over Ethernet Injector KPOE-800-1P KPOE-800-2P Installation Guide DOC.090201 1 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide Copyright January 2004 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 A010430357 The information contained in this document

More information

Summit Virtual Chassis Design and Installation Guide

Summit Virtual Chassis Design and Installation Guide Summit Virtual Chassis Design and Installation Guide Extreme Networks, Inc. 10460 Bandley Drive Cupertino, California 95014 (888) 257-3000 http://www.extremenetworks.com Published: June 1998 Part No: 120031-00

More information

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual LNP-0602 series 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A

More information

QuickSpecs. Models HP V1810-8G Switch

QuickSpecs. Models HP V1810-8G Switch Overview Models HP V1810-24G Switch HP V1810-8G Switch J9450A J9449A Key features Web-managed Layer 2 Gigabit switch 8- and 24-port models Fanless switch for silent operation Two dual-personality mini-gbic

More information

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide . Signamax Connectivity Systems Model 065-7405A Series User s Guide 1 Quick Start Guide This quick start guide describes how to install and use the Compact. Capable of operating at temperature extremes

More information

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide Signamax Connectivity Systems Hardened Ethernet Switch Model 065-7405G Series User s Guide 1 Quick Start Guide Hardened Ethernet Switch This quick start guide describes how to install and use the Hardened

More information

Cisco Series Gigabit Ethernet Half-Height Line Card

Cisco Series Gigabit Ethernet Half-Height Line Card Cisco 10000 Series Gigabit Ethernet Half-Height Line Card Figure 1. Cisco 10000 Series Gigabit Ethernet Half-Height Line Card In order to continue to meet customers increasing needs for modularity and

More information

GigaVUE-2404 // Data Sheet

GigaVUE-2404 // Data Sheet Mgmt Console M/S Rdy 10/100/1000 PORTS (SFP) G1 G2 G3 G4 G1 G2 G3 G4 1 1 2 2 3 3 4 5 4 5 6 6 7 7 8 8 SLOT 2 PORTS 9 16 SLOT 1 PORTS G1-G4 PORTS 1-8 SLOT 3 PORTS 17 24 PS ALARM CUTOFF UP WHEN INSTALLED

More information

Rugged MediaConverter

Rugged MediaConverter Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M

Gigabit Ethernet Switch With 10G Uplinks. Hardware Manual MS400860M Gigabit Ethernet Switch With 10G Uplinks Hardware Manual MS400860M Gigabit Ethernet Switch with 10G Uplinks Hardware Manual II About This Guide Purpose Audience Conventions This guide details the hardware

More information

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart PoE (Power over Ethernet) and High Power PoE Ethernet Switch. This is the switch of choice for harsh environments

More information

RGS-7168GCP / RGS-7168GCP-E

RGS-7168GCP / RGS-7168GCP-E RGS-7168GCP / RGS-7168GCP-E Features Industrial 24-port rack-mount managed Gigabit Ethernet switch with 16xGigabit combo ports and 8x100/1000Base-X, SFP socket Support 24 Gigabit ports with 16 x Gigabit

More information

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual 10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual v1.02 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to

More information

ProCurve Switch 2600 Series

ProCurve Switch 2600 Series The ProCurve Switch 2600 series is a collection of low-cost, stackable, multi-layer, managed switches with 48, 24, or 8 auto-sensing 10/100 ports and dual-personality ports for 10/100/1000 or mini-gbic

More information

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual 100Base-FX to 10/100Base-TX PoE Media Converter FCU-1802Px User s Manual Trademarks Copyright Antaira Technologies 2013. Contents subject to revision without prior notice. Antaira is a registered trademark

More information

HPE Port and 48-Port Switches Quick Setup Guide

HPE Port and 48-Port Switches Quick Setup Guide HPE 2530 24-Port and 48-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and

More information

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual 8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...

More information

IKS-G6524A/G6824A Series Quick Installation Guide

IKS-G6524A/G6824A Series Quick Installation Guide IKS-G6524A/G6824A Series Quick Installation Guide Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:

More information

Hardened PoE Ethernet Switch

Hardened PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description

More information

Preface. Managed Media Converter Chassis System

Preface. Managed Media Converter Chassis System Preface The Managed Media Converter Chassis System supports the Media Converter Chassis to monitor the each Media Converter ( CO ) or Chassis Manager status and to configure advanced function of the Managed

More information

Cisco SRW Port Gigabit Switch: WebView Cisco Small Business Managed Switches

Cisco SRW Port Gigabit Switch: WebView Cisco Small Business Managed Switches Cisco SRW2016 16-Port Gigabit Switch: WebView Cisco Small Business Managed Switches Secure, Reliable, Intelligent Switching for Small Businesses Highlights 16 high-speed ports optimized for the network

More information

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP. Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication

More information

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature Feature Summarize Packing list Panel layout IES7110-2GS Series Managed Industrial Ethernet Switch User manual Shenzhen 3onedata Technology Co., Ltd. Tel: +86-755-26702668 Fax: +86-755-26703485 www.3onedata.com

More information

Cisco SGE Port Gigabit Switch Cisco Small Business Managed Switches

Cisco SGE Port Gigabit Switch Cisco Small Business Managed Switches Cisco SGE2000 24-Port Gigabit Switch Cisco Small Business Managed Switches High-Performance, Reliable, Stacking Switch for Small Businesses Highlights 24 high-speed ports optimized for the network core

More information

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001 Installation Guide DOC.050523-EM400X -1- The information contained in this document is subject to change without prior notice. Copyright (C) All

More information

ProCurve Switch 1400 Series

ProCurve Switch 1400 Series The ProCurve Switch 1400 series provides plug-and-play simplicity for high-bandwidth connectivity. The Switch 1400 series consists of two switches. The 1400-24G is a 24-port 10/100/1000 switch with 22

More information

Signamax Connectivity Systems Industrial 10/100BASE-TX Ethernet Extender

Signamax Connectivity Systems Industrial 10/100BASE-TX Ethernet Extender Signamax Connectivity Systems Industrial 10/100BASE-TX Ethernet Extender U S E R S G U I D E Signamax Connectivity Systems Industrial Ethernet Extender Model 065-1167A User s Guide FCC Warning This equipment

More information

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH 8 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH WITH 1 PORT 1000BASE-X UPLINK OR 1 PORT 100/1000BASE-X UPLINK 8 PORTS 10/100/1000BASE-T

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS, Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500 * Fax 724-746-0746 56-80830BB-00 Rev A1 June 2007 JUNE 2007 LGC320A, LGC321A, LGC322A,

More information

6GK6050-0MM Transmission rate. Interfaces

6GK6050-0MM Transmission rate. Interfaces Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches Layer 3 / Routers > RUGGEDCOM RX5000 / MX5000 Multi-Service Platform managed 6GK6050-0MM2.-... RUGGEDCOM

More information

FSW-1609TFX FSW-2409TFX

FSW-1609TFX FSW-2409TFX LevelOne FSW-1609TFX FSW-2409TFX 16/24-Port Fast Ethernet Switch w/ fiber module slot User Manual Version 1.1-0609 FCC Warning This equipment has been tested and found to comply with the regulations for

More information

ex-s1110-xt Gigabit Ethernet Extenders

ex-s1110-xt Gigabit Ethernet Extenders ex-s1110- Gigabit Ethernet Extenders perle.com/products/10-100-1000-industrial-ethernet-extender.shtml 10/100/1000 Industrial Temperature Copper Extender Extends 10/100/1000Base-T Ethernet up to 10,000

More information

Save installation time and money with PoE

Save installation time and money with PoE 8-Port Gigabit Ethernet PoE+ Web-Managed Switch with 2 SFP Ports IEEE 802.3at/af Power over Ethernet (PoE+/PoE) Compliant, 140 W, Endspan, Desktop, 19" Rackmount Part No.: 561167 Save installation time

More information

QuickSpecs. Models. Features and Benefits Connectivity. HP ProCurve Switch 1800 Series. Overview. Retired. HP ProCurve Switch G

QuickSpecs. Models. Features and Benefits Connectivity. HP ProCurve Switch 1800 Series. Overview. Retired. HP ProCurve Switch G Overview HP ProCurve Switch 1800-24G HP ProCurve Switch 1800-8G Models HP ProCurve Switch 1800-8G HP ProCurve Switch 1800-24G J9029A J9028B Key features Web-managed Layer 2 Gigabit switch 8- and 24-port

More information

ProCurve Routing Switch 9300m Series. Overview. ProCurve Routing Switch 9315m. DA Worldwide Version 5 August 18, 2006 Page 1

ProCurve Routing Switch 9300m Series. Overview. ProCurve Routing Switch 9315m. DA Worldwide Version 5 August 18, 2006 Page 1 Overview ProCurve Routing Switch 9315m DA - 11852 Worldwide Version 5 August 18, 2006 Page 1 Overview ProCurve Routing Switch 9308m ProCurve Routing Switch 9304m Models ProCurve Routing Switch 9315m ProCurve

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter

More information

IMC-21GA Quick Installation Guide

IMC-21GA Quick Installation Guide IMC-21GA Quick Installation Guide Moxa Industrial Media Converter Edition 4.0, June 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide MIL-S24002TGxx 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch User Guide Rev.B 08-DEC2005 Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A - EN55024

More information

16-SLOT IN-BAND MANAGEMENT CHASSIS

16-SLOT IN-BAND MANAGEMENT CHASSIS FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS User's Guide. Version 1.6 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

Installation. Package Contents CHAPTER

Installation. Package Contents CHAPTER CHAPTER 2 Installation This chapter describes how to install your Catalyst 3500 XL switches and interpret the power-on self-tests (POST) that ensure proper operation. Read the topics, and perform the procedures

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728 STAT PWR1 PWR2 FAULT MASTER COUPLER LNK/ACT SPEED FDX/HDX MODE COUPLER RING PORT PORT 1 2 3 4 M1 M2 M3 M4 PT-2 PT-2 Series IEC 6150-3 24+4G-port Gigabit modular managed Ethernet switch IEC 6150-3, IEEE

More information

Hardened Web-Smart High Power PoE Ethernet Switch

Hardened Web-Smart High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart High Power PoE (Power over Ethernet) Ethernet Switch. This is the switch of choice for harsh environments

More information

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

Media Converters & Chassis

Media Converters & Chassis Expandable Chassis System The Chassis-based Media Converter product lineup includes various independent media converters and a chassis capable of housing up to 16 media converters. You can start with a

More information

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet 4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet Table of Contents...1 Contents...1 Introduction...1 Ordering Information...1 Key Features/Benefits...2 Flexible and Scalable Switch Clustering Architecture...3

More information

HP ProCurve Switch 1800 Series

HP ProCurve Switch 1800 Series Key features Web-managed Layer 2 Gigabit switch 8- and 24-port models Fanless switch for silent operation Two dual-personality mini-gbic slots (J9028B) Industry-leading warranty Datasheet HP ProCurve Switch

More information