PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!
|
|
- Beverly Mathews
- 5 years ago
- Views:
Transcription
1 PRODUCT DESCRIPTI The DL is a dialer module, which contains a Digital Alarm Communicator Transmitter (DACT). The dialer sends alarm, supervisory, and trouble information to a compatible Digital Alarm Communicator Receiver (DACR) through one or two dial-up telephone lines (two per NFPA ). The dialer supports PPS / format and Dual Tone Multi-Frequency (DTMF) or Pulse mode dialing. Every hours, the dialer performs an automatic test call to verify communications between the fire alarm panel and the Central Monitoring Station (CMS). INSTALLATI Disconnect external ac power and battery power to cabinets before installing or removing components. Failure to do so may result in serious injury or loss of life.! Carefully match mounting holes up with spacers to ensure proper connector mating. Mounting the DL Install three metal spacers (P/N 69) in the three locations indicated below. Mount the DL on the three metal spacers. Mate connector P on the DL with connector JE on the Main Controller Module. Secure the DL to the spacers with the screws provided. JE Warning! Caution! Observe static-sensitive material handling practices. Install metal spacers here. with the screws provided Input power Supervisory Active Mounting Phone line Wall connector Line supervision Communications protocol CMS telephone numbers FCC registration number Dialing retries Clock accuracy Compliance Programming phone Environmental conditions Temperature range Humidity range Event SPECIFICATIS ma ma Mounts on the Main Controller Module One/two loop start lines on public switched telephone network, pulse or DTMF dialing. Party, ground start, and PBX start lines are not acceptable. NFPA requires two phone lines. Standard RJX or RJ8X phone jack Trouble when line voltage less than V and line current less than ma. SIA pulse format PPS / double round, Hz handshake, 9 Hz carrier Two -digit numbers ZUSA-9-AL-E five to ten Within one hour/year Communications Canada, CS-; FCC/CFR parts and 68; NFPA ; UL 86; ULC S-M8 Any tone dial phone with an RJ plug to F ( to 9 C) to 9%, non-condensing Dialer codes Code Fire alarm report codes - Fire alarm restore codes - Normal hr check-in 9 Abnormal hr check-in 9 Supervisory alarm 9 Trouble 9 Trouble / supervisory restore 9 AC power fail 96 Battery trouble 9 Telephone line trouble 98 Dialer disabled 99 PRODUCT DIAGRAM Main Controller Module P Dialer DL -X Metal spacer P JE -X /6 panhead screw INSTALLATI SHEET: DL Dialer Module Digital Alarm Communicator Transmitter INSTALLATI SHEET P/N: 8 REVISI LEVEL:. DATE: AUG FILE NAME: 8.CDR APPROVED BY: M. Slack CREATED BY: B. Graham Main Controller Module EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 9-9- FAX CHESHIRE, CT: FAX OWEN SOUND, CANADA: 9-6- FAX INTERNATIAL, CANADA: 9-- FAX 9--9
2 WIRING Notes Connect J and J to RJX or RJ8X telephone jacks installed by an authorized telephone company representative (CAA or CA8A in Canada). Install the RJX (RJ8X) jacks within ft (. m) of the control panel and allow two extra feet of cable for a total of ft (. m). The dialer installation kit includes a protective bushing (P/N 66) for enclosure knockouts. Before programming can proceed, the dialer will notify the central monitoring station (CMS) for any previously entered numbers. Ring (red) RJX 8 pin modular connector for phone line Tip (green) Black Surge protector Yellow To phone line wired same as phone line Premises phones Ring (red) RJX 6 8 pin modular connector for phone line No T-taps! Surge protector ft (. m) Use J when using only one phone circuit Tip (green) J J J # Programming phone The phone key pad is only for module programming. Rotary dial phones will not work. See dialer programming, on the following pages, for more information. Enable/disable switch Dialer Status LED FCC information The dialer complies with Part 68 of the FCC rules. The Dialer's FCC registration number and Ringer Equivalence Number (REN) are on the back of the dialer. This information must be provided to the telephone company if requested. An FCC compliant telephone cord and modular plug cord is supplied with the dialer. The dialer is designed to be connected to the telephone network using the supplied cord and an RJX or RJ8X jack, which must also comply with FCC Part 68 rules. The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of RENs should not exceed five (). To be certain of the number of devices that may be connected to a line as determined by the total RENs, contact the local telephone company. If the dialer causes harm to the telephone network, the telephone company will notify you an advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify you as soon as possible. You will also be advised of your right to file a complaint with the FCC, if you believe it is necessary. The telephone company may make changes in it's facilities, equipment, operations, or procedures that could affect the operation of the dialer. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. 6 If trouble is experienced with the dialer, for repair or warranty information, contact GS Building Systems Corp. 6 Parkland Drive, Sarasota, Florida USA. If the dialer is causing harm to the telephone network, the telephone company may request you disconnect the dialer until the problem is resolved. No repairs may be performed on the dialer by the user. IMPORTANT INFORMATI 8 The dialer can not be used on public coin phones or party line service provided by the telephone company. Canada DOC information Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. Notice: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading. The temination on a loop may consist of any combination of devices subject only to the requirements that the sum of the Load Numbers of all devices does not exceed. P/N: 8 REV:. Page of
3 A confirmation tone indicates the correct entry of a program item. DIALER PROGRAMMING Phone lines must be loop start on a public-switched network. PBX, party lines, and ground start lines are not acceptable. The dialer does not place calls, monitor the panel, or monitor the phone lines during the programming process. After initial programming, the dialer notifies the central monitoring station that it is disabled before programming can proceed. Two phone lines are required to comply with NFPA. Notes 6 The dialer will automatically switch to pulse dialing after three consecutive failures using tone mode. It will switch back to tone dialing after failing to connect using pulse mode, upon re-programming, or upon enabling disconnect switch. Entering the programming mode Connect the phone to J. Take the handset off the hook. J The status LED will display two rapid green flashes, and then turn solid green. J J Entering the password When the Status LED turns solid green, press (GSBS) on the telephone keypad. Entering the dialer data Listen for the confirmation tone to verify that the dialer has accepted the password. Note: Enter the required information for all 8 programming items in sequence. Before programming can proceed, the dialer will notify the CMS for any previously entered numbers. The status LED will display a slow green flash during the dialing process. The status LED will display a steady green LED to indicate that the dialer is ready for programming. Programming the primary site ID number (item ) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays a steady green pattern entered. interrupted by amber flashes. Enter the -digit ID number on the telephone keypad. Use leading zeroes as required. Programming the primary CMS number (item ) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays a steady red pattern entered. interrupted by amber flashes. Enter a to -digit number on the telephone keypad to specify the primary CMS number. Programming the secondary site ID number (item ) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays a steady green pattern entered. interrupted by double amber flashes. Enter the -digit ID number on the telephone keypad. Use leading zeroes as required. Programming the secondary CMS number (item ) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays a steady red pattern entered. interrupted by double amber flashes. - Continued - P/N: 8 REV:. Page of Enter a to -digit number on the telephone keypad to specify the secondary CMS number.
4 Programming or line operation (item ) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays a steady green pattern entered. interrupted by rapid amber flashes. Enter or on the telephone keypad. The default setting is. Programming the number of CMS retry calls (item 6) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays rapid green flashes. entered 6. 6 Enter, 6,, 8, 9, or on the telephone keypad. The default is (). Programming the retry interval (item ) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays double green flashes. entered. Enter,, or 6 on the telephone keypad to specify the number of seconds. The default is. Programming the daily supervision delay (item 8) Press the following telephone keys: Listen for the confirmation Make sure that the status LED displays a slow amber flash. entered 8. 8 Enter a -digit number on the telephone keypad to specify the delay period (in hours). The default is. Exiting the programming mode Disconnect the phone from J. J J J Put the handset on the hook. Status LED indications during dialer operations Color Green Green Amber Pattern Rapid flash Single flashes Single flashes Description Waiting for password entry Call to CMS in progress Dialer in trouble Amber Double flashes Dialer disabled Restoring default values Enter the password Press the following telephone keys: according to the preceding instructions on this installation sheet. Verifying programmed entries Enter the password according to the preceding instructions on this installation sheet. Press the following telephone keys: Programming item number # Make sure that the status LED displays a steady green pattern. Listen for the confirmation tone to verify that it sounds the contents of the selected item through the handset. The dialer resets to its default values and returns it to item of the programming mode. Testing the dialer Activate and open an SDC and an NAC to verify that the CMS receives the proper signal. Verify that failure of the primary signal path results in the transmission of a trouble signal through the secondary signal path within minutes. Verify that failure of the secondary signal path results in the transmission of a trouble signal through the primary signal path within minutes. Notes The primary signal path is along the phone line connected to J. The secondary signal path is along the phone line connected to J. P/N: 8 REV:. Page of
5 INSTALLATI Mount the LED/switch modules. Inner door (side view) Inner door (rear view) Plunger Grommet Note: Do not try to insert the plunger and grommet into the mounting holes at the same time. Insert the grommet first and then the plunger to avoid damaging them. LED/switch module (side view) LED/switch module (rear view) Dip switch J J J J J J J J J J J J J J -LCD To Main Controller Module Connect the LED/Switch Module ribbon cables Connect the ribbon cable from J on the -LCD to J on the first module. Connect the ribbon cable from J on the first module to the J on the second module. Repeat step until you reach the last module. Note: White indicates the correct dipswitch position. Set the dip switches on the LED/switch modules. Dip switch setting LED addresses Switch addresses PRODUCT DESCRIPTI The front panel LED/switch modules consist of 6 individual LEDs for point annunciation. The LED/switch modules provide eight groups of two LEDs combined with a switch. See the specifications for available LED color options. The protected slip-in label next to each LED/switch identifies its function. Communication with the Main Controller Module requires no point to point wiring, because it is multiplexed using plug-in ribbon cables. Any combination of three annunciator and switch modules may be mounted on the panel's inner door. Blank Plates (model -FBP) fill unused inner door spaces. Models -RY -6G -6R -6Y -8RY -FBP Models -6G8S -6R8S -6Y8S -8GYS -8RYS SPECIFICATIS LED/switch options Model Description -RY red LEDs over yellow LEDs -6G 6 green LEDs -6G8S 6 green LEDs and 8 switches -6R 6 red LEDs -6R8S 6 red LEDs and 8 switches -6Y 6 yellow LEDs -6Y8S 6 yellow LEDs and 8 switches -8RY 8 red LEDs over 8 yellow LEDs -8RYS 8 red / 8 yellow alternating LED/switch pairs -8GYS 8 green / 8 yellow alternating LED/switch pairs Blank plate option Switches Temperature range Humidity range -FBP Momentary push button to F ( to 9 C) to 9%, non-condensing INSTALLATI SHEET: Front Panel LED(/Switch) Modules INSTALLATI SHEET P/N: REVISI LEVEL:. DATE: JUN Related documentation: -LCD installation sheet EDWARDS SYSTEMS TECHNOLOGY, INC. SARASOTA, FL: 9-9- FAX CHESHIRE, CT: FAX OWEN SOUND, CANADA: 9-6- FAX INTERNATIAL, CANADA: 9-- FAX 9--9 FILE NAME:.CDR APPROVED BY: J. Massing CREATED BY: B. Graham
6
Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)
Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL
More informationMODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300
Model CMX-300 Technical Practice October 2015 Issue 6 MODEL CMX-300 Service Observing System 1. GENERAL 1.1 The Dees CMX-300, installed with the Dees CM-30, increases the number of stations to be observed
More informationWIRESPEED ADSL MODEM (MODEL 2000) User Guide
WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...
More informationDIAMOND ELITE SERIES USERS GUIDE
DIAMOND ELITE SERIES USERS GUIDE COVERS MODELS L2-E L2S-E L2-5E L2S-5E L2-10E L2S-10E DIAMOND ELITE SERIES TELEPHONE DIAGRAM Hold Key Line 1 Line 2 Conference Key Handset Holder Ringer Volume Control Data
More informationSuperBus 2000 Phone Interface/Voice Module Installation Instructions
SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module
More informationUSER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 552 Series High Speed Telco Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M552-E Rev. G Revised 01/27/10 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
More informationWS must be used in a temperature controlled place. It is compliant to ETS Class T
Important Information about the Sagemcom F@ST 2705 WS: Operational working: F@ST2705 WS must be used in a temperature controlled place. It is compliant to ETS 300 019-1-3 Class T 3.2 standard: 1. Temperature
More informationUT3620 Triple NT1 Installation Guide
UT3620 Triple NT1 Installation Guide UT3620 Triple NT1 Installation Guide Revision 1.00 1/3/2000 Information in this guide is subject to change without notification. Copyright 2000 Alpha Telecom, Inc.
More informationAREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.
AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,
More informationOpen Applications Interface (OAI) Installation and Setup
Open Applications Interface (OAI) Installation and Setup Link Wireless Telephone System Link 3000 MCU Part Number: 72-0059-07 Issue A NOTICE SpectraLink Corporation has prepared this document for use by
More informationHomeWorks Telephone Interface. Instructions for Installation and Use Please Read Before Installing. HWI-TEL9 18 V 60 Hz 300 ma
Instructions for Installation and Use Please Read Before Installing General Description The HWI-TEL9 Single Line Telephone Interface provides access to up to ten different functions or events in the HomeWorks
More informationSuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions
6512 PWR ALM TST LINE ETHERNET SuperLine IAD Models 6501, 6502, 6510, 6511, and 6512 Installation Instructions Document Number 6500-A2-GN10-00 September 1999 SuperLine TM IAD Front View Rear View BASE
More informationEX-UBT AVB/USB EXPANDER OPERATION MANUAL
EX-UBT AVB/USB EXPANDER OPERATION MANUAL SEPTEMBER 2018 EX-UBT PRODUCT DESCRIPTION The EX-UBT is an AVB/USB expander for use in Tesira systems. It provides reliable digital audio I/O via USB in installations
More informationSERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.
WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone
More informationSERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA
WPP-531-X-ADA OR SSP-511-X-ADA-SPK1.07-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA HANDS FREE EMERGENCY WEATHERPROOF TELEPHONE OR MODEL SSP-511- X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED
More informationSERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)
SSP-363-E-(SSP-365-E)-ADT1.03-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-363-E (FORMERLY SSP-365-E) STAINLESS STEEL PANEL TELEPHONE WITH 12 BUTTON AUTOMATIC DIALER EQUIPPED WITH ADT1.03 FIRMWARE Serving the
More informationG.SHDSL NTU DECEMBER 2006 LB510A
DECEMBER 2006 LB510A G.SHDSL NTU CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500
More informationG.SHDSL NTU with Fixed Serial Interfaces
DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,
More informationBig button Speakerphone MODEL: FC-8814
FUTURE CALL Big button Speakerphone MODEL: FC-8814 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT SAFETY INSTRUCTIONS
More informationBIG BUTTON PHONE WITH ONE TOUCH DIALING AND
FUTURE CALL LLC BIG BUTTON PHONE WITH ONE TOUCH DIALING AND 40db HANDSET VOLUME MODEL: FC-1507 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of
More informationSERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE
WPP(HOB)-531-D2 OR SSP-511-D2-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE OR MODEL SSP-511-D2 STAINLESS STEEL PANEL
More informationSERVICE MANUAL MODEL SSW-521-D2-ADA
SSW-521-D2-ADA-SPK1.07UNVLr3-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-D2-ADA STAINLESS STEEL HANDS FREE WALL TELEPHONE WITH OPTIONAL ADA FEATURE AND OPTIONAL SECOND-NUMBER AUTO-DIAL FEATURE EQUIPPED
More informationZM24x Quick-Connect Industrial Modem. User s Manual
ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of
More informationPICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613
FUTURE CALL PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT
More informationGN 4170 headset telephone Hands-free ease with sleek, space-saving phone
For more information and technical specifications: www.gnnetcom.com CORPORATE HEADQUARTERS Northeastern Blvd. Nashua, NH 002 1-00-2-1-0--1100 Fax: 1-0--1122 2002 GN Netcom, Inc. All rights reserved. -0A
More informationThis document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.
Hotwire 6205 ADSL Modem Installation Instructions Document Number 6205-A2-GZ40-10 September 2004 Introduction Congratulations on becoming the owner of a Hotwire ADSL USB Modem. You will now be able to
More informationNT1B-300 Rack Installation Instructions
The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies
More informationOwner s Instruction Manual
Owner s Instruction Manual Advanced Healthcare Telephone Model 5150 Contents IMPORTANT SAFETY INSTRUCTIONS...3 BOX CONTENTS...4 FEATURES...4 ON/OFF SWITCH...4 DIAL BUTTONS...4 RECEIVER VOLUME CONTROL...4
More informationTCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone
TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone OPERATION MANUAL APRIL 2018 TCM-1, TCM-1A & TCM-1EX PRODUCT
More informationSERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE
WPP-531-D OR SSP-511-D-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE WITH OPTIONAL ADA
More informationTemperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions
Temperature Guard Models VM500-3 & VM500-3HT Home Guard Model VM500-2 Operating Manual and Installation Instructions Index Temperature Guard model VM500-3 Description 3 Programming Overview 3 Programming
More informationSERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)
SSW-521-F-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-F (FORMERLY SSW-521-FS) STAINLESS STEEL HANDS FREE WALL TELEPHONE OPTIONAL ADA FEATURE AVAILABLE EQUIPPED WITH SPK1.07UNVL FIRMWARE Serving
More information2GI. Touch Screen Wireless Keypad
2GI Touch Screen Wireless Keypad For Remote Control of the 2GIG Security System INSTALL INSTRUCTIONS This document describes the basic installation information for the 2GIG TS1 and the steps necessary
More informationTemperature Guard Models VM500-3 & VM500-3HT. Home Guard Model VM Operating Manual and Installation Instructions
Temperature Guard Models VM500-3 & VM500-3HT Home Guard Model VM500-2 Operating Manual and Installation Instructions Index Temperature Guard model VM500-3 Description 3 Programming Overview 3 Programming
More informationFour IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty
Warranty Four IFB is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the Four IFB needs repair, you must call us to get an authorization, and then carefully
More informationSERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE
WPP(HOB)-531-D OR SSP-511-D-SPK1.07UNVLADA-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE
More informationSERVICE MANUAL MODEL SSP-561-X-ADA
SSP-561-X-ADA- SPK1.07r2-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-561-X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH BRAILLE EMERGENCY PLATE AND SPK1.07r2 FIRMWARE Serving the Telephone Industry
More informationSmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide
SmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide Approval Models that are equipped with telecom interfaces have been approved for connection to the public telecommunication
More informationSERVICE MANUAL. MODEL SSW-321-Fr1
SSW-321-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL SSW-321-Fr1 MINI WALL TELEPHONE EQUIPPED WITH RECEIVER-OPERATED MAGNETIC HOOKSWITCH; INTERNAL VOLUME CONTROL AND NOISE REDUCTION CIRCUIT; XFD PCB. Serving
More informationQuickTap. JK Audio. Telephone Handset Tap. User Guide
QuickTap Telephone Handset Tap User Guide JK Audio Welcome Thank You Thank you for purchasing the JK Audio QuickTap. Please read this guide for instructions on using it. Getting Assistance If you have
More informationSERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE
MHW-341-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE EQUIPPED WITH VOLUME CONTROL, BACKGROUND NOISE ELIMINATION, XFD PRINTED CIRCUIT, AND RECEIVER- OPERATED
More informationFUTURE CALL USER MANUAL PICTURE PHONE WITH SPEAKERPHONE MODEL: FC-1007 SP / PD
FUTURE CALL PICTURE PHONE WITH SPEAKERPHONE MODEL: FC-1007 SP / PD USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of device except specified. IMPORTANT
More informationSERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE
WPP(HOB)-331-D or SSP-311-D ATD-11 Issue 5.00 SERVICE MANUAL FOR MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE EQUIPPED
More informationService Modem Installation Instructions
4100-6030 Service Modem Installation Instructions Introduction This publication describes the installation procedure for the 4100-6030 Service Modem Card, and describes the difference between the service
More informationSERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD
SSC-500-F-(501-FSZ)-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry
More informationInstalling And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems
R Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems The Analog Terminal Interface The ATI-D-1PT is a multipurpose, on-premise accessory
More informationSERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)
SSC-303-D(303DS)-ADI2.01-650-541-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-303-D (FORMERLY 303-DS) STAINLESS STEEL AUTOMATIC DIALING TELEPHONE EQUIPPED WITH ADI2.01 FIMWARE Serving the Telephone Industry Since
More informationPAGEPAC 6 V INSTALLATION There are several ways to connect PagePac 6 to your telephone system.
PagePac by Issue 2 PAGEPAC 6 V-5323006 INTRODUCTION PagePac 6 is a compact, 6 watt, voice-paging system that integrates single-zone paging capability to your telephone system. Dimensions/Weight 6.0 W x
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
SSP-3-F -ISSUE 4.0 Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 0, or 5 -BK Braille Keypad -PBVC Pushbutton
More informationTE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer
TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer INTSTALLATION & PROGRAMMING MANUAL Alpha Communiations www.alphacommunications.com 42 Central Drive Farmingdale NY 11735 Phone: 631-777-5500
More informationOPAL 1010S. The Teledex one-line. speakerphone specifically MANUAL OWNER S. designed for the international. hospitality industry.
OPAL 1010S The Teledex one-line MANUAL OWNER S speakerphone specifically designed for the international hospitality industry. INCLUDED IN YOUR PACKAGE Handset Base Unit Coiled Handset Cord Line Cord Clear
More informationDSU 5600 Data Service Unit USER MANUAL
DSU 5600 Data Service Unit USER MANUAL 61200.078L1-1D May 1997 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 Phone: (205) 963-8000 1997 ADTRAN, Inc. All rights reserved. Printed in USA.
More information0 # ES&P VENTURES CORP. Engineering Services & Products
1 4 7 * 2 3 5 6 8 9 0 # 1 4 7 * 2 3 5 6 8 9 0 # ES&P VENTURES CORP. Engineering Services & Products SYSTEM FEATURES Capacity for up to 1000 Tenants. Simple Upgrade from Autodialer to No Telephone Line
More informationOwner s Manual. Models: ECO650LCD, ECO850LCD. Not suitable for mobile applications
Warranty Registration Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual ECO-UPS Systems with LCD Models: ECO650LCD, ECO850LCD Not suitable for
More informationSERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)
SSC-301-F OR BLC-301-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-301-F (FORMERLY 301-FS) OR MODEL BLC-301-F (FORMERLY 301-F) CHARGE-A-CALL TELEPHONE Serving the Telephone Industry Since 1930 Communication
More informationALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply
October 2012 IL42-4031C ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply General This leaflet contains general installation instructions for ALPHA Plus and A3 ALPHA meters with the
More informationOPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR
1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 10, or 15 -BK Braille Keypad -PBVC Pushbutton volume control
More information345 Encinal Street Santa Cruz, CA
Printed in the U.S.A. 69047-01 (11 04) 2000 2004 Plantronics, Inc. All rights reserved. Plantronics, the logo design, Plantronics and the logo design combined are trademarks or registered trademarks of
More informationULTRALINE HOME DSL ROUTER (MODEL 7401) ULTRALINE HOME DSL ROUTER WITH USB (MODEL 7400) USER GUIDE
ULTRALINE HOME DSL ROUTER (MODEL 7401) ULTRALINE HOME DSL ROUTER WITH USB (MODEL 7400) USER GUIDE Copyright 2004 Westell, Inc. 030-300381 Rev. A This User Guide provides information about Westell s UltraLine
More informationAudio Cable (For CD Players Only) Sensor Board Cable
"Telecommunication Products to solve Telecommunication Problems" Audio Cable (For CD Players Only) CK-1P Promotion- On-Hold Adapter For the KX-TG4500, KX-TG4000 & KX- TG2000 Phones Sensor Board Power Cube
More informationTelephone Entry System
Telephone Entry System TE-200-II C-0902 (PCB w/ mounting plate) 234 FISCHER AVENUE COSTA MESA, CA 92626 (714) 424-6500 (800) 840-0288 (714) 424-6510 FAX HTTP://WWW.CHANNELVISION.COM E-MAIL: SALES@CHANNELVISION.COM
More informationD56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7
D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 SECTION 4 - FRONT PANEL INDICATORS...8 SECTION 5 - INTERFACE SIGNALS...9 SECTION 6 -
More informationQH2 BLUETOOTH PHONE HUB SYSTEM USER'S GUIDE QH2 BLUETOOTH PHONE HUB SYSTEM USER'S GUIDE
QH2 BLUETOOTH PHONE HUB SYSTEM USER'S GUIDE QH2 BLUETOOTH PHONE HUB SYSTEM USER'S GUIDE Welcome! Thank you for purchasing the ClearSounds QH2 Bluetooth Phone Hub System. We hope that you enjoy the hands-free
More informationSERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F
SSW-321-F OR BLW-321-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-F OR MODEL BLW-321-F MINI WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering
More informationSERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)
SSC-303-F-650-521-CAC6.00-ISSUE4.1 SERVICE MANUAL FOR MODEL SSC-303-F (FORMERLY 303-FS) CHARGE-A-CALL TELEPHONE EQUIPPED WITH CAC6.00 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment
More informationSetting up your modem s connections
Setting up your modem s connections The PowerBook G3 Internal Modem is already installed in your PowerBook. To use the modem you need m the single-line telephone cord supplied with your PowerBook, which
More informationSERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)
SSP-550-X-(SSP-510-X)-LPSPKRPCB-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-550-X (FORMERLY SSP-510-X) HANDS FREE ELEVATOR PHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry Since
More informationSERVICE MANUAL MODEL SSW-321-X
SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,
More informationSERVICE MANUAL MODEL SSW-321-D
SSW-321-D-XFD-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-D MINI WALL TELEPHONE EQUIPPED WITH XFD PRINTED CIRCUIT BOARD Communication Equipment & Engineering Company Serving the Telephone Industry Since
More informationInstalling And Programming The Off-Premise Extension Interface On The Digital Communications System
R Installing And Programming The Off-Premise Extension Interface On The Digital Communications System 1.0 Introducing The Off-Premise Extension Interface This publication describes the features, applications,
More informationUser's Guide MD 14.4L Industrial Grade Dial Modems Book 1 of 2
User's Guide MD 14.4L Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No. 49-0002-001 Rev.A TABLE of CONTENTS 1. STANDARDS...Page 2 2. PRODUCT OVERVIEW...Page 3 3. GENERAL
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationEnterprise Session Border Router, IAD
SmartNode 5480/5490 Series Enterprise Session Border Router, IAD Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Part Number: 07MSN5480-90-QS, Rev.
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More informationUser Manual Back-UPS BE650MC
User Manual Back-UPS BE650MC Inventory Back-UPS ES 650 bu075b This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive
More informationSecond Phone Line Kit Manual for sx1480/fx2080
Second Phone Line Kit Manual for sx1480/fx2080 Contents Regulatory information...i Users in United States of America... i FCC Part 15... ii Users in Canada...iii Canadian ICES-003...iii Setting up...1-1
More informationMultiple Digital Messaging Unit
HARRIS DRACON DIVISION Multiple Digital Messaging Unit Installation and Configuration Copyright 994 Harris Dracon All Rights Reserved Written/Printed in U.S.A. 0II7404-00 Issue, Nov. 994 Notice Every effort
More informationTelephone Line Monitor USER GUIDE
Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone
More informationIC+ 56k External Data Fax Voice Modem IP568x User s Guide
IC + 56k External Data Fax Voice Modem IP568x FCC Requirements This equipment complies with Part 68 of the FCC Rules. On the bottom of this equipment is a label that contains, among other information,
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationUser's Guide MD 14.4 Industrial Grade Dial Modems Book 1 of 2
User's Guide MD 14.4 Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No. 49-0002-001 Rev.A TABLE of CONTENTS 1. STANDARDS...Page 2 2. PRODUCT OVERVIEW...Page 3 3. GENERAL
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More information4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.
K5484 7/00 /
More informationCIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB
CIB 3125 (122A) Off-Premises Range Extender Installation Instructions Installed By Qualified Technician Only CIB 3125 106793441 1992 AT&T All Rights Reserved Printed in USA Issue 3 August 1992 NOTICE Every
More informationClarity P400 TM. Featuring Clarity Power Technology. Clarity P400 User Guide P A ~ F R A N Ç A I S
Clarity P400 TM Featuring Clarity Power Technology Clarity P400 User Guide E N G L I S H E S P A ~ N O L F R A N Ç A I S TABLE OF CONTENTS SAFETY INSTRUCTIONS...4 INTRODUCTION...7 PACKAGE CHECKLIST...8
More informationSERVICE MANUAL MODEL SSW-520-F
SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West
More informationFDS / FDS-R / FDS-PS
FDS / FDS-R / FDS-PS USER MANUAL For use with 120V 60Hz input. Output is 120V 60Hz at 5amps 600W MAX. switched. ETL LISTED Conforms to UL STD 1241 3091594 79-15167-00 REV. A www.fiberstars.com Page 1 of
More informationService Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches
Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 10, or 15 -IVC Internal Volume Control & Background Noise Reduction
More informationADSL GATEWAY (MODEL 2410) USER GUIDE
ADSL GATEWAY (MODEL 2410) USER GUIDE Copyright 2002 Westell, Inc. 030-300205 Rev. C Printed in the United States of America January 2003 CONTENTS 1. Product Description...1 2. Safety Instructions...1 3.
More informationProduct Documentation on the World Wide Web
TM 9000 Series Access Carrier with AC Power Supply Installation Instructions Document Number 9000-A2-GN1D-60 June 1999 The 9000 Series Access Carrier with an ac power supply is a metal enclosure that supports
More informationChapter 2. Installing the Chapter 2. Contents
Contents Chapter 2 Installing the 3512 Overview... 2-2 Unpacking... 2-2 Telephone Equipment... 2-3 Customer-Provided Telephone Equipment... 2-3 Telephone Company Procedures and Regulatory Requirements...
More informationDS1 USER GUIDE. For Technical Assistance call the Manufacturers direct Ph AM - 5PM West Coast Pacific Time
DS1 USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code :NC TABLE OF CONTENTS Description Pages
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationTHANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3
THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.
More informationLeased Line. NIONs. NCB Routers. Typical Application of NCB Routers
NCB/IM Router Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding configuration on the
More informationUSER GUIDE. BLUETOOTH HEADSET system
USER GUIDE Plantronics VOYAGER 510-USB BLUETOOTH HEADSET system 0 0 0 TABLE OF CONTENTS PACKAGE CONTENTS Package Contents 3 Features 4 Charging 5 Powering 6 Pairing 7 Installing PerSono Suite Software
More informationVE8012A/VE8012AR DUAL NETWORKED STATION PORT
ISSUE 3 VE8012A/VE8012AR DUAL NETWORKED STATION PORT INTRODUCTION The VE8012A/VE8012AR Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.
More informationSecond Line Option. User's Manual. For use with DL170
Second Line Option User's Manual For use with DL170 Table of contents Setting up...............................................1 Get the Second phone line module installed..................1 Enter settings
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More information