Supplementary Manual for Model 287a Ionizer Performance Analyzer. 287a-1/100A V1.12 P/N

Size: px
Start display at page:

Download "Supplementary Manual for Model 287a Ionizer Performance Analyzer. 287a-1/100A V1.12 P/N"

Transcription

1 Supplementary for Model 287a Ionizer Performance Analyzer 287a-1/100A V1.12 P/N

2 IPA 287a Display and Operational Chart Press [On/Off] to turn on the unit ME MONROE 287a Version 1.12 Press [On/Off] or wait for 5 seconds MemUsed A30%M50% ClrData Y/N? N Press and hold [ON/OFF] between 2-4 seconds Memory used: Auto-sequence tests 30%. tests 50%. If no data in memory (I.e. A=0%M=0%), this screen is not shown. to make the choice. Then press [Enter] to select and exit. Or press [ON/OFF] for not to do anything and exit. Temperature=28C, Battery=9.0V, Humidity=34%RH longer than 4 seconds Off Set-Up Review data Press [^] or [v] : scroll through the menu [Enter] : select the menu item [ON/OFF]: back to Main Clear data RvwData A30%M50% ClrData A30%M50% ClrData N Y/N? A30%M50% See Page 2 Auto Sequence Auto Seq Auto Seq Test delay test duration Tst delay 5 sec Bal (Y/N) Y Bal dur 22 sec Tst delay 5 sec 0-30 sec Bal (Y/N) Y Y/N? Bal dur 22 sec sec to scroll through the choices. Then press [Enter] to select and exit. Or press [ON/OFF] for not to do anything and exit. Auto shut down AutoShtDwn 10min AutoShtDwn 10min 0=disabl 1-15min Restore factory defaults: AutoSeq= Tst delay = 5 = Y duration= 30 sec. AutoShtDwn= 1 minute Fac. Default Exit Fac. Default N Y/N? or [ON/OFF] back to Main IPA287Supplement Page 1 Monroe Electronics, Inc.

3 From Page 1 M1D+ 6.8s M1TH 25C 31%RH M1D + 6.8s test Test #1 (1-0) + test time in seconds test Test #1 (1-0) Temperature Humidity M1TH 25C 31%RH M2D- 7.3s M2TH 25C 31%RH M3B+0016v -0010v M3TH 25C 31%RH M2D - 7.3s test Test #2 (1-0) - test time in seconds M3B+0012v -0003v test Test #3 (1-0) + and - Voltage peaks M4D+ 10.6s M4TH 23C 30%RH MDA+08.7s -07.3s 11D+07.3s -08.9s 12D+09.3s -06.2s 13D+20.1s -12.9s 1AD+09.3s -06.2s MDA+08.7s -07.3s Averages + and - averages 11D+07.3s -08.9s AutoSeq. group #1 (1-0) Test #1 (1-3) test + and - decay time in seconds 1AD+09.3s -06.2s AutoSeq. group #1 (1-0) Average + and - decay average of the group 1Ba+0017v -0005v 1TH 25C 30%RH AutoSeq. group #1 (1-0) test + and - voltage peaks or [ON/OFF] back to Main 1Ba+0017v -0005v IPA287Supplement Page 2 Monroe Electronics, Inc.

4 Plus Test (press [^] button ) The 287 unit will start by zeroing then Charge to over +1050V, then. The decay timer starts at +1000V and stops at +100V. Test (press and hold [^] or [v] button for 2-4 seconds) The 287 will start by zeroing, then for the time duration. Start recording Min and Max voltage levels after 5 seconds. Up to 10 test results can be stored in memory. They are named M1 thru M0 where M0 is the 10 th test. Press [+] and hold longer than 4 seconds + between 2-4 seconds + 950V +Charge +1030V V 3.6s Test #1 (1-0) + Timer starts at 1000V and stops at 100V 28C 9.0V 34% M2B + 1V 5.2s +0002mx 0004mn Test #2 (1-0) will abort any on-going test. After the test complete, review data begins. will scroll through the data. or [ON/OFF] back to Main Voltage update duration timer Min and Max voltages start recording after 5 seconds. IPA287Supplement Page 3 Monroe Electronics, Inc.

5 Minus Test (press [v] button ) The 287 unit will start by zeroing then Charge to over +1050V, then. The decay timer starts at +1000V and stops at +100V. Test (press and hold [^] or [v] button for 2-4 seconds) The 287 will start by zeroing, then for the time duration. Start recording Min and Max peaks after 5 seconds. Press [-] and hold longer than 4 seconds - between 2-4 seconds - 950V -Charge -1030V V 3.6s Test #3 (1-0) - 28C 9.0V 34% M4B +1V 5.2s +0002mx 0004mn Test #4 (1-0) will abort any on going test. After the test complete, review data begins. will scroll through the data. or [ON/OFF] back to Main Voltage update duration timer min and max voltages start recording after 5 seconds. Timer starts at 1000V and stops at 100V IPA287Supplement Page 4 Monroe Electronics, Inc.

6 Auto Sequence Group Test (press [AUTO] button ) The 287 unit will perform up to 10 groups of automatic test sequences and store the results in memory. Groups are named 1 thru 0 where 0 is the 10 th. Each group has 3 +decay, 3-decay, and an optional balance test. The sequence can be set in the Set-Up Menu. test : Zeroing to <5V, Charge to over +/-1050V, then. The decay timer starts at +/-1000V and stops at +/-100V. Test: Zeroing to <5V, then for the time duration. Start recording Voltage peaks after 5 seconds. The delay time between the tests can be set in the Set-Up Menu. Auto Sequence Test Press [AUTO] and hold longer than 2 seconds AUTO + 950V +Charge Group #1 (1-0) Test #1 (1-3) V V 3.6s + 20V 8.6s Delay 6 sec go on for the other 5 decay tests... Timer starts at 1000V and stops at 100V. 28C 9.0V 34% 1Ba + 1V 5.2s +0002mx 0004mn Review test results Group #1 (1-0) test Voltage update duration timer Max and min voltages start recording after 5 seconds. will abort any on going test and back to Main. After the test complete, review data begins. will scroll through the data. or [ON/OFF] back to Main IPA287Supplement Page 5 Monroe Electronics, Inc.

7 Error Messages What to do... Battery Low 6.2V Off in 5 sec. Change the battery. 28C 9.0V Er%RH Humidity is out of 10% - 90% range or sensor failure. If sensor failure, contact factory for repair V +Charge Unable to charge Unable to charge to 1050V. Make sure nothing is contacting the charge plate and the standoffs underneath are clean. This may also be caused by too much load on the plate. Press enter to return to the main screen. Remove the 287 from the ionizer and recheck. If problem persists contact the manufacturer for calibration V 200.s failed time out at 200 seconds, and the plate reading is still above 100V. Check your ionizer. Recommend using Monroe Model 288 EEProm Fail Contact factory. IPA287Supplement Page 6 Monroe Electronics, Inc.

Model 287a Ionizer Performance Analyzer

Model 287a Ionizer Performance Analyzer Operator s Manual Model 287a Ionizer Performance Analyzer P/N 0340172 287a-1/100 V1.13 06222017 100 Housel Ave PO Box 535 Lyndonville NY 14098 585-765-2254 fax: 585-765-9330 monroe-electronics.com CONTENTS

More information

1366 INSTRUCTION MANUAL

1366 INSTRUCTION MANUAL RS Humidity / Temperature Meter 1366 INSTRUCTION MANUAL R ULL C WET DEW C TABLE O CONTENTS TITLE PAGE 1. SPECIICATIONS... 1 2. RONT PANEL DESCRIPTION... 2 3. MEASURING PROCEDURE... 4 4. MAINTENANCE...

More information

Operators Manual Monroe Electronics, Inc. Model 288B Charge Plate Monitor P/N /100 V

Operators Manual Monroe Electronics, Inc. Model 288B Charge Plate Monitor P/N /100 V Operators Manual Monroe Electronics, Inc. Model 288B Charge Plate Monitor P/N 0340174 288-1/100 V2.07 042111 CONTENTS Specifications Section 1 Specifications Page 4 Accessories included Page 5 What this

More information

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL ISF-1DF SERIES-E www.insize.com ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL V0 Attention Description Regardless of whether the unit is ON or OFF, Don t exceed the capacity of the gauge. At 110%

More information

IONIZATION SOLUTIONS

IONIZATION SOLUTIONS IONIZATION SOLUTIONS Charge Plate Monitor Model 280A User s Manual About Simco-Ion Simco-Ion serves the semiconductor, mass storage, flat panel display (FPD), general electronics, automotive, medical device,

More information

High Accuracy Gloss Meter Operation Manual. This manual is only suitable for our single angle and multi-angles gloss meters.

High Accuracy Gloss Meter Operation Manual. This manual is only suitable for our single angle and multi-angles gloss meters. Content Introduction... 1 Cautions... 1 1. External structure description... 2 2. Switch on/off... 3 2.1 Startup... 3 2.2 Shutdown... 4 3. Basic operation... 4 3.1 Menu Operation... 4 3.2 Enter the main

More information

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6. CONTENTS TITLE PAGE 1. Introduction.. 1 2. Specifications... 1 3. Symbol Definition and Button Location... 2 4. Operation Instructions.... 3 4.1 Power-Up...3 4.2 Connection of the Temperature Probe...

More information

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT 3 3 User Manual Thermohygrometer with NIST-Traceable Calibration Model 20250-11 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Thermohygrometer (Model 20250-11) offers fast response

More information

Operators Manual Monroe Electronics, Inc. Model 300 Charge Plate Monitor

Operators Manual Monroe Electronics, Inc. Model 300 Charge Plate Monitor Operators Manual Monroe Electronics, Inc. Model 300 Charge Plate Monitor P/N 0340193 Console Firmware Rev 1.05 Plate Assembly Firmware Rev 1.02 01302015 100 Housel Ave PO Box 535 Lyndonville NY 14098 1-800-821-6001

More information

FG-3000R Digital Force Gauge Operation Manual

FG-3000R Digital Force Gauge Operation Manual FG-3000R Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

Type K/J Thermometers

Type K/J Thermometers Type K/J Thermometers 800005 CONTENTS INTRODUCTION....2 FRONT PANEL DESCRIPTION...3 LCD DISPLAY....4 OPERATION INSTRUCTION...5 Power Up....5 Connecting the Thermocouples....5 Selecting Temperature Scale....5

More information

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0]

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0] KERN & Sohn GmbH Ziegelei 1 Tel: 0049-[0]7433-9933-0 D-72336 Balingen-Frommern Fax: 0049-[0]7433-9933-149 E-Mail: info@kern-sohn.de Internet: www.kern-sohn.de E Service Manual Electronic Precision Balances

More information

www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk

More information

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS DTM-321 T1 T2 K-TYPE REL HOLD C F TEMP: ( ) HUMIDITY: 20 C 4 F 200 328 0 C F POWER-UP OPTIONS 60 C 140 F 1370 2498 100 %RH C F CONTENTS TITLE PAGE I. Safety Information... 1 II. Introduction...... 1 III.

More information

-auto Power Off- T1/T2/T1-T2

-auto Power Off- T1/T2/T1-T2 -auto Power Off- T1/T2/T1-T2 CONTENTS 1. Safety Information...1 2. Product Overview...3 3. Recognize Meter..... 4 3.1 Component...4 3.2 Display...5 3.3 Keys Description...6 4. Setting Meter...8 4.1 SETUP

More information

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments Model R8050 Sound Level Meter Instruction Manual reedinstruments www com REED 1-877-849-2127 info@reedinstruments.com www.reedinstruments.com Table of Contents Safety... 2 Specifications... 3 Instrument

More information

Technical manual for HP8480 Main battery switch with current monitor. + Low power output for rain light. + Battery discharge warning output.

Technical manual for HP8480 Main battery switch with current monitor. + Low power output for rain light. + Battery discharge warning output. Technical manual for HP8480 Main battery switch with current monitor. + Low power output for rain light. + Battery discharge warning output. Date: 2018-03-27\KT Page 1 of 10 Table of content 1) Product

More information

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL USERS INFORMATION MANUAL Heating & Cooling Systems MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. I2:34 72 72 Heat only, or Cool

More information

FG-3000 Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual FG-3000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

True RMS AC Voltage/Current Datalogger

True RMS AC Voltage/Current Datalogger User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long

More information

GOLD SERIES DVD/CD Duplicator Manual

GOLD SERIES DVD/CD Duplicator Manual GOLD SERIES DVD/CD Duplicator Manual User s Manual Version 3.0 0 TABLE OF CONTENTS Introduction 2 Setup 11 LCD Front Panel Overview 2 o Auto Start Time 11 Menu Overview 3-5 o Display Mode 12 Functions

More information

PLAYBACK MODE. Blue: Manual Record. Red: White: Motion Detection Record Schedule Record

PLAYBACK MODE. Blue: Manual Record. Red: White: Motion Detection Record Schedule Record PLAYBACK MODE SEARCH AND PLAY To access the search playback list go to Menu and select Search and Play The Search and Play list will come up and list off all of the recordings you have starting with the

More information

I. PANEL DESCRIPTION... 1

I. PANEL DESCRIPTION... 1 Table of Contents I. PANEL DESCRIPTION... 1 II. OPERATING INSTRUCTION... 7 1. MA OUTPUT... 7 1A. GENERAL OPERATION 4-20MA... 7 1B. SELECT 0-20MA OR 0-24MA... 8 1C. ENTER A VALUE LESS THAN 1... 9 2. % (PERCENTAGE)

More information

DPM-3221 Digital DC Power Meter with data logging capability.

DPM-3221 Digital DC Power Meter with data logging capability. Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),

More information

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual Blu-ray/DVD/CD Duplicator Control Manual User s Manual 0 TABLE OF CONTENTS Introduction 2 Setup 12 LCD Front Panel Overview 2 o Auto Start Time 12 HDD Manager o Select Image o Disc => Controller Connection

More information

4-Channel Thermometer

4-Channel Thermometer 4-Channel Thermometer 800023 4-Channel Thermometer - 800023 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced or transmitted in

More information

CFM/CMM Hot-Wire Thermoanemometer

CFM/CMM Hot-Wire Thermoanemometer User Manual CFM/CMM Hot-Wire Thermoanemometer with NIST-Traceable Calibration Model 20250-16 Max Min Flow Temp THE STANDARD IN PRECISION MEASUREMENT 2 Introduction The Digi-Sense CFM/CMM Hot-Wire Thermoanemometer

More information

Multifunction Calibrator

Multifunction Calibrator Multifunction Calibrator Model CL TC - - - C V _ TECPEL CO., LTD. Features:. - (KΩ load, V Loop Supply). -.,-.V, -.V. K, J, E, T Thermocouple ( C and ). Frequency -.. Basic Accuracy. Easy Key-pad Operation.

More information

NIDEC-SHIMPO INSTRUMENTS

NIDEC-SHIMPO INSTRUMENTS Series FGE-HXY Force Gauges Operation Manual NIDEC-SHIMPO INSTRUMENTS Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the

More information

Heavy Duty Datalogging Light Meter

Heavy Duty Datalogging Light Meter User's Guide Heavy Duty Datalogging Light Meter with PC Interface Model HD450 Introduction Congratulations on your purchase of the Extech HD450 Digital Light Meter. The HD450 measures illuminance in Lux

More information

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual HDT-318 Thermo-Hygrometer with Data Logger (Air Humidity/Temperature) Instruction Manual CONTENTS 1. SAFETY INFORMATION... 2 2. GENERAL DESCRIPTION... 2 3. FEATURES... 2 4. SPECIFICATIONS... 3 5. SYMBOL

More information

DPM Digital DC Power Meter with Data logging capability. User Manual

DPM Digital DC Power Meter with Data logging capability. User Manual DPM-3232 Digital DC Power Meter with Data logging capability User Manual Introduction As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-60A), Watt, and it also displays

More information

Light Meter with Bar Graph

Light Meter with Bar Graph Light Meter with Bar Graph 840020 Instruction Manual SPER SCIENTIFIC LTD. TABLE OF CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 MEASUREMENT PROCEDURES... 3-4 ZERO ADJUSTMENT... 4 BATTERY REPLACEMENT...

More information

User Manual Video Borescope Model

User Manual Video Borescope Model User Manual Video Borescope Model 20250-27 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Video Borescope (Model 20250-27) is ideal for the inspection of ductwork, wiring locations,

More information

RS Stock No Instruction Manual RS Input Data Logging Thermometer

RS Stock No Instruction Manual RS Input Data Logging Thermometer RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2

More information

User Manual. Thermocouple Datalogging Thermometer. Model EA15

User Manual. Thermocouple Datalogging Thermometer. Model EA15 User Manual Thermocouple Datalogging Thermometer Seven (7) Thermocouple input types K, J, T, E, R, S, N Dual thermocouple Input with PC Interface Model EA15 Additional User Manual Translations available

More information

USER MANUAL Video Particle Counter with built in Camera Model VPC300

USER MANUAL Video Particle Counter with built in Camera Model VPC300 USER MANUAL Video Particle Counter with built in Camera Model VPC300 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model VPC300

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850025 Mini Environmental Quality Meter 850025 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced

More information

4-Channel Datalogging Thermometer

4-Channel Datalogging Thermometer 4-Channel Datalogging Thermometer 800024 4-Channel Datalogging Thermometer - 800024 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced

More information

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

Heavy Duty Datalogging Light Meter

Heavy Duty Datalogging Light Meter User's Guide Extech HD450 Datalogging Heavy Duty Light Meter Extech HD450-NIST Datalogging Heavy Duty Light Meter Heavy Duty Datalogging Light Meter with PC Interface Model HD450 Introduction Congratulations

More information

C F MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH HOLD TIMER T2 T1 RS-232 DC9V. h:m:m:s HUMIDITY TEMPERATURE METER POWER - UP OPTIONS

C F MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH HOLD TIMER T2 T1 RS-232 DC9V. h:m:m:s HUMIDITY TEMPERATURE METER POWER - UP OPTIONS HOLD INSTRUCTION MANUAL T2 T1 RS-232 DC9V RS232 HUMIDITY TEMPERATURE METER K y m-d T1 h:m:m:s T2 C F HOLD TIMER MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH POWER - UP OPTIONS + Disable AUTO

More information

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,

More information

USB Temperature and Humidity Data Logger Instruction Manual

USB Temperature and Humidity Data Logger Instruction Manual USB Temperature and Humidity Data Logger Instruction Manual 1 4 2 3 5 1. Display 2. Set key 3. + key 4. - key 5. USB port - 1 - 1. Temperature 4 2. MAX/MIN value 5 3. Humidity 1 2 3 4. Memory status 6

More information

Series FGE-XY Force Gauges Operation Manual

Series FGE-XY Force Gauges Operation Manual Series FGE-XY Force Gauges Operation Manual Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the temperatures can exceed 104

More information

EM10 TEMPERATURE / HUMIDITY /DEW POINT METER

EM10 TEMPERATURE / HUMIDITY /DEW POINT METER EM10 TEMPERATURE / HUMIDITY /DEW POINT METER User Manual - 1 - Introduction Thank you for purchasing the temperature/humidity/dew point meter from SUPCO. Please take a few minutes to browse through this

More information

Standard Model Digital Force Gauge ZTS series

Standard Model Digital Force Gauge ZTS series Standard Model Digital Force Gauge ZTS series Feature 1 Clear display / Easy setting. Feature 2 You can capture peak value precisely due to high sampling. Feature 3 Easy data management on PC with included

More information

User Manual. Borescope. Model THE STANDARD IN PRECISION MEASUREMENT

User Manual. Borescope. Model THE STANDARD IN PRECISION MEASUREMENT User Manual Model 20250-28 Borescope THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Borescope (Model 20250-28) is ideal for the inspection of ductwork, wiring locations, piping, vehicles,

More information

C2000 POWER METER With Data Storage

C2000 POWER METER With Data Storage C2000 POWER METER With Data Storage Operation Instructions CONTENT 1. Features 2. Functions 3. Operation 4. Specification 2 1. Features The Appointech C2000 handheld power meter has calibrated readings

More information

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,

More information

Hand held use More precise force measurement Force-displacement measurement

Hand held use More precise force measurement Force-displacement measurement High functioning/high performance Digital Force Gauge ZT Series High sampling rate: Captures force value more precisely. Multifunction and easy set up with languages. New I/O function: Continuous data

More information

NOTES TABLE OF CONTENTS

NOTES TABLE OF CONTENTS NOTES TABLE OF CONTENTS 1.0 Introduction.................................................... 04 1.1 Standard Features 1.2 Accessories Included 2.0 Overview.....................................................

More information

-Direct.com FG-3000 Digital Force Gauge Operation Manual

-Direct.com FG-3000 Digital Force Gauge Operation Manual FG-3000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual Single-Input Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-91 Thermistor Meter Model 20250-93 RTD Meter Model 20250-95 THE STANDARD IN PRECISION

More information

TC41-Thermocouple Thermometers User Manual

TC41-Thermocouple Thermometers User Manual TC41-Thermocouple Thermometers User Manual Product Registration cs@perfect-prime.com Product Introduction This thermometer can be used to measure up to 4 different temperatures simultaneously, and with

More information

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof Temperature/Rh Data logger Users Manual USB Datalogger IP 65 Water Proof TABLE OF CONTENTS FEATURES & SPECIFICATIONS... 3 START UP AND GENERAL OPERATION... 7 LCD Display... 8 Sampling Rate... 9 Recording

More information

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide DTW 400/DTW 405 - Digital Torque Tester/Screwdriver User s Guide LIST OF EQUIPMENT 1. Digital Torque Tester/Screwdriver (DTW 400 with CW and CCW ratchet (1/4 female hex) 2. 2 Phillips tips (DTW 405 with

More information

ARCTIC AIR DC OLED. Digital Control Operations Manual

ARCTIC AIR DC OLED. Digital Control Operations Manual ARCTIC AIR DC OLED Digital Control Operations Manual Micro Air Corporation Phone (609) 259-2636 124 Route 526 WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Before you start: 1. Applying power:

More information

TEMPERATURE / HUMIDITY /DEW POINT METER

TEMPERATURE / HUMIDITY /DEW POINT METER TEMPERATURE / HUMIDITY /DEW POINT METER Users Manual . Introduction Thank you for purchasing the temperature/humidity/dew point meter from us. Please take a few minutes to browse through this user manual

More information

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2 POWER SERIES Plus 3 in 1 AC Voltage Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful

More information

TA 888 Hot Wire Anemometer

TA 888 Hot Wire Anemometer TA 888 Hot Wire Anemometer Max Min Temp Your purchase of this HOT WIRE ANEMOMETER makes a step forward for you into the field of precision measurement. Although this ANEMOMETER is a complex and delicate

More information

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2.

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2. OFFSET SETUP READ REC HOLD TC2100 Digital Thermometer User s Manual T1 T2 K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN K INTERVAL hour:min T1 T2 : F CAL min:sec C POWER MAX AVG MIN HOLD SETUP THERMOMETER

More information

FH125/FT121. Temperature / Humidity LCD Graphing Logger FH125 SET CURSOR. 1 Hour/Div 1 1 : 12 : 23 01/03/02 (ESC)

FH125/FT121. Temperature / Humidity LCD Graphing Logger FH125 SET CURSOR. 1 Hour/Div 1 1 : 12 : 23 01/03/02 (ESC) 72. 1 F- 27.8 H-- 1 Hour/Div 1 1 : 12 : 23 01/03/02 DICKSON FH125/FT121 Temperature / Humidity LCD Graphing Logger 100 80 60 40 20 0 SET CURSOR (ESC) FH125 FH121 Specifications FH121 Temperature Scales:

More information

+91-8048764953 Countronics http://www.processcontrols.co/ An ISO 9001:2008 certified company, we are a leading manufacturer and exporter of electronic process control instruments for industrial use. We

More information

IV-18 (ИВ-18) VFD Tube Clock. Instructions. Contents. v Energy Pillar

IV-18 (ИВ-18) VFD Tube Clock. Instructions. Contents. v Energy Pillar IV-18 (ИВ-18) VFD Tube Clock Energy Pillar Instructions v1.2.0 Designer: Yan Zeyuan. China Website: E-mail: yanzeyuan@163.com Contents Attention..... 2 Functional Features.. 2 Technical Specifications....

More information

Standard Model Digital Force Gauge ZTS series

Standard Model Digital Force Gauge ZTS series Standard Model Digital Force Gauge ZTS series Feature 1 Clear display / Easy setting. Feature 2 You can capture peak value precisely due to high sampling. Feature 3 Easy data management on PC with included

More information

M4-ATX-HV 6-34V Intelligent ATX Power Supply

M4-ATX-HV 6-34V Intelligent ATX Power Supply M4-ATX-HV 6-34V Intelligent ATX Power Supply Installation Guide Version 1.0e P/N M4-ATX-HV-01 Before you start Please take a moment and read this manual before you install the M4-ATX-HV in your vehicle.

More information

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160 USER GUIDE Dual Input True RMS AC Voltage/Current Datalogger Model DL160 Introduction Congratulations on your purchase of this Dual Input Voltage / Current datalogger. With this meter, you can monitor

More information

Installation Instructions

Installation Instructions SPECIFICATIONS TS-400 InteliSwitch Digital Time Switch 20/277VAC Voltages... 20/277VAC, 50/60Hz Requirements @ 20VAC... 0-800W ballast @ 277VAC... 0-200W ballast @ 25VAC.../6 hp Time-Out Adjustment...

More information

SATA DVD/CD Duplicator Controller User s Manual

SATA DVD/CD Duplicator Controller User s Manual SATA DVD/CD Duplicator Controller User s Manual Version 2.0 TABLE OF CONTS Chapter 1 Introduction 1 10. Setup 11 11. HDD Manager 13 LCD Front Panel Overview 1 o Start-up Menu 11 o Select Image 13 Hardware

More information

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter User Manual KI6501 series Optical CWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher

More information

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC Mini Sound Meter 850014 Instruction Manual SPER SCIENTIFIC CONTENTS 1. INTRODUCTION... 2 2. PANEL DESCRIPTION... 3 3. OPERATING INSTRUCTIONS... 4 3-A. Measuring Procedures... 4 3-B. Hold Function... 5

More information

SuperHeat Psychrometer Models RH350 and RH355 (kit)

SuperHeat Psychrometer Models RH350 and RH355 (kit) User's Guide SuperHeat Psychrometer Models RH350 and RH355 (kit) Introduction Congratulations on your purchase of the Extech RH350 SuperHeat Psychrometer. This device measures Differential Temperature

More information

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual CONTENTS 1. GENERAL DESCRIPTION... 2 2. SAFETY INFORMATION... 2 3. FEATURES... 2 4. SPECIFICATIONS...

More information

INSTRUCTION MANUAL. Handy Polaris 2

INSTRUCTION MANUAL. Handy Polaris 2 INSTRUCTION MANUAL Handy Polaris 2 **This page is left blank** Table of Contents 1 General... 4 2 Menus... 5 2.1 Calibrate... 5 2.2 Set Salinity... 5 2.3 View Log... 5 2.4 Setup Menus... 5 2.4.1 User Interface...5

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Single-Input Thermometers with NIST-Traceable Calibration Thermocouple

More information

AFMS, Garmin G5 AML STC Rev. 1 FAA APPROVED Page 2 of 7

AFMS, Garmin G5 AML STC Rev. 1 FAA APPROVED Page 2 of 7 LOG OF REVISIONS Date of Rev Page Description FAA Approval Approval 1 All Original Issue See Cover See Cover FAA APPROVED Page 2 of 7 TABLE OF CONTENTS SECTION 1. GENERAL... 4 SECTION 2. LIMITATIONS...

More information

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1 POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.

More information

RTG-3 2-Tone RETURN PATH TEST GENERATOR

RTG-3 2-Tone RETURN PATH TEST GENERATOR RETURN PATH TEST GENERATOR Features 2-Tone output mode. Both channels can be individually toggled on/off. Extended frequency range (5-204MHz) for compatibility with EuroDOCSIS 3.1 Channel and frequency

More information

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual HygroPalm 0 Portable Humidity Temperature Indicator Instruction Manual v 3 20040211 - 2 Contents Overview... 3 General Description... 3 Power Source... 3 Optional Docking Station (PD1-ACA)... 3 Unit System...

More information

SecureShot HC Quick Start Instruction Page

SecureShot HC Quick Start Instruction Page SecureShot HC Quick Start Instruction Page Your new SecurShot HC has been factory pre-programmed and tested to fit most applications. It is ready-to-go right out of the box. An SD card is installed, and

More information

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Cup Thermo-Anemometer. Model AN400 User's Guide Cup Thermo-Anemometer Model AN400 Introduction Congratulations on your purchase of the Extech Cup Thermo-Anemometer. The AN400 measures air velocity in five units of measure: feet per minute

More information

Datalogging ph Meter

Datalogging ph Meter Specifications Range Resolution Accuracy ph 0.00 ~ 14.00 ph 0.01 ph ±0.02 ph mv -999.9 ~ 999.9mV 0.1 mv ±0.2 mv @ -99.9 ~ 99.9mV ±2 mv @ other ranges Temperature -23 ~ 176 F (-5 ~ 80 C) 0.1 F( 0.1 C) Compensation

More information

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR 1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com

More information

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual DPM-3321 Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model User Manual Bi-Directional DC Power Meter with built-in USB data logger & adapter. The new DPM-3321

More information

Mini Environmental Quality Meter

Mini Environmental Quality Meter Mini Environmental Quality Meter 850025 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com Mini Environmental Quality Meter 850025 Copyright

More information

Datasheet: K-33 BLG Sensor

Datasheet: K-33 BLG Sensor Datasheet: K-33 BLG Sensor The K- 33 BLG (bio- logger) sensor is designed to measure percentage of carbon dioxide up to 30%, as well as temperature and humidity. This makes it an excellent sensor for enclosed

More information

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications. / Handheld Temperature and Temperature / RH Indicators Contents: Applications and Accessories Warranty / This versatile temperature indicator accepts J, K and T thermocouple probes with mini-connectors.

More information

HANDHELD CALIBRATOR-MULTIMETER OC502-t

HANDHELD CALIBRATOR-MULTIMETER OC502-t OC502-t_GBM_21311 HANDHELD CALIBRATOR-MULTIMETER OC502-t Owner s Manual ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch

More information

NIDEC-SHIMPO INSTRUMENTS

NIDEC-SHIMPO INSTRUMENTS Series FGE-XY Force Gauges Operation Manual NIDEC-SHIMPO INSTRUMENTS Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the

More information

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model User Manual Dual-Input Data Logging Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-92 Thermistor Meter Model 20250-94 RTD Meter Model 20250-96 THE STANDARD

More information

Indoor Air Quality Meter/Datalogger

Indoor Air Quality Meter/Datalogger User Manual Indoor Air Quality Meter/Datalogger Model EA80 CC Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EA80 Indoor Air

More information

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT User Manual Data Logging Light Meter with NIST-Traceable Calibration Model 20250-00 THE STANDARD IN PRECISION MEASUREMENT Introduction The Digi-Sense Data Logging Light Meter (Model 20250-00) is designed

More information

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter 10 Series Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) 0.01kV (0 to ±0.99 kv) RoHS IZE Check

More information

FERGUSON BEAUREGARD. User Manual

FERGUSON BEAUREGARD. User Manual FERGUSON BEAUREGARD inodeconfig ic User Manual FERGUSON BEAUREGARD inodeconfig ic User Manual The Ferguson Beauregard AUTO-CYCLE and inodeconfig ic program and manuals are Copyright by Ferguson Beauregard.

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com Model 8706 Digital Pocket Psychrometer Instruction Manual reedinstruments com Table of Contents Features... 3 Specifications... 4 Instrument Description... 5 Measuring Procedures... 6--9 Auto Power Off...

More information