1 POP-Net Essential DICOM Conformance Statement Revision 4.0 Software Version 4.0 and after Date: February 9, 2005 Prepared for Page 1

2 Copyright EBM Technologies, Inc. Head office Japan office EBM Technologies, Inc. 5Fl., No.516, Sec.1, Neihu Rd., Taipei, 114 Taiwan Phone: Fax: URL: EBM Technologies Japan, Inc Ozakudai, Hamura-shi, Tokyo, Japan Phone: Fax: URL: Page 2

3 1. DICOM COMFORMANCE STATEMENT OVERVIEW POP-Net Essential supports display of DICOM image objects obtained over the network, from interchange media, or from PS 3.10 files loaded from the local file system. POP-Net Essential supports querying a remote system for a list of DICOM objects that may then be retrieved to the local system. It also supports sending locally loaded images across the network to another system. Most storage SOP Classes defined as of DICOM 2004 can be received, stored and transmitted by POP-Net Essential, but some may not be loaded and viewed. All single and multi-frame with grayscale and color images may be displayed. Both hierarchical and relational queries are supported. SOP Classes Table 1-1 NETWORK SERVICES Instance Transfer and Verification User of Service (SCU) Provider of Service (SCP) Verification Yes Yes Commitment Push Model Yes No Computed Radiography Image Stored and Viewed Yes Digital X-Ray Image For Stored and Viewed Yes Presentation Digital X-Ray Image For Processing Stored and Viewed Yes Digital Mammography X-Ray Image Stored and Viewed Yes For Presentation Digital Mammography X-Ray Image Stored and Viewed Yes For Processing Digital Intra-oral X-Ray Image For Stored and Viewed Yes Presentation Digital Intra-oral X-Ray Image For Stored and Viewed Yes Processing CT Image Stored and Viewed Yes Enhanced CT Image Stored only Yes Ultrasound Multi-frame Image Stored and Viewed Yes (Retired) Ultrasound Multi-frame Image Stored and Viewed Yes MR Image Stored and Viewed Yes Enhanced MR Image Stored only Yes MR Spectroscopy Stored only Yes Nuclear Medicine Image (Retired) Stored and Viewed Yes Ultrasound Image (Retired) Stored and Viewed Yes Page 3

4 Ultrasound Image Stored and Viewed Yes Secondary Capture Image Stored and Viewed Yes Multi-frame Grayscale Byte Secondary Stored and Viewed Yes Capture Image Multi-frame Grayscale Word Secondary Stored and Viewed Yes Capture Image Multi-frame True Color Secondary Capture Stored and Viewed Yes Image Standalone Overlay Stored only Yes Standalone Curve Stored only Yes 12-lead ECG Waveform Stored only Yes General ECG Waveform Stored only Yes Ambulatory ECG Waveform Stored only Yes Hemodynamic Waveform Stored only Yes Cardiac Electrophysiology Waveform Stored only Yes Basic Voice Audio Waveform Stored only Yes Standalone Modality LUT Stored only Yes Standalone VOI LUT Stored only Yes Grayscale Softcopy Presentation State Stored and Viewed Yes SOP Class with images X-Ray Angiographic Image Stored and Viewed Yes X-Ray Radiofluoroscopic Image Stored and Viewed Yes X-Ray Angiographic Bi-Plane Image Stored and Viewed Yes (Retired) Nuclear Medicine Image Stored and Viewed Yes VL Endoscopic Image Stored and Viewed Yes Video Endoscopic Image Stored and Viewed Yes VL Microscopic Image Stored and Viewed Yes Video Microscopic Image Stored and Viewed Yes VL Slide-Coordinates Microscopic Image Stored and Viewed Yes VL Photographic Image Stored and Viewed Yes Video Photometric Image Stored and Viewed Yes Ophthalmic Photography 8 Bit Image Stored and Viewed Yes Ophthalmic Photography 16 Bit Image Stored and Viewed Yes Basic Text SR Stored and Viewed Yes (Note 1) Enhanced SR Stored and Viewed Yes (Note 1) Comprehensive SR Stored only Yes Mammography CAD SR Stored only Yes Key Object Selection Document Stored and Viewed Yes with images Chest CAD SR Stored only Yes Positron Emission Tomography Image Stored and Viewed Yes RT Image Stored and Viewed Yes Page 4

5 Query/Retrieve Study Root Information Model FIND Yes (Note 2) No Study Root Information Model MOVE Yes No Note 1: Viewing SR objects requires optional Report Reader software, POP-Net SR. Note 2: Relational Queries is supported. Media Application Profile Table 1-2 MEDIA SERVICES Write Files (FSC or FSU) Read Files (FSR) Compact Disk - Recordable General Purpose CD-R Yes Yes Basic Cardiac XA on CD-R Yes Yes 1024 XA on CD-R Yes Yes CT and MR on CD-R Yes Yes DVD General Purpose DVD-RAM Yes Yes MOD Ultrasound - Image Display / Spatial Calibration / Combined Calibration - Single Frame / Multi-frame Yes Yes Page 5

6 2. TABLE OF CONTENTS 1. DICOM COMFORMANCE STATEMENT OVERVIEW TABLE OF CONTENTS INTRODUCTION Revision History Audience Remarks Abbreviations and Acronyms: NETWORKING Implementation Model Application Data Flow Functional Definitions of AE s ECHO-SCP STORAGE-SCP STORAGE-SCU FIND-SCU MOVE-SCU PRINT-SCU Sequencing of Real-World Activities AE Specifications ECHO-SCP SOP Classes Association Policies General Number of Associations Asynchronous Nature Implementation Identifying Information Association Initiation Policy Association Acceptance Policy Activity Receive Echo Request Description and Sequencing of Activities Accepted Presentation Contexts Extended Negotiation SOP Specific Conformance SOP Specific Conformance to Verification SOP Class Presentation Context Acceptance Criterion Page 6

7 Transfer Syntax Selection Policies STORAGE-SCP SOP Classes Association Policies General Number of Associations Asynchronous Nature Implementation Identifying Information Association Initiation Policy Association Acceptance Policy Activity Receive Request Description and Sequencing of Activities Accepted Presentation Contexts Extended Negotiation SOP Specific Conformance SOP Specific Conformance to SOP Classes Presentation Context Acceptance Criterion Transfer Syntax Selection Policies Response Status STORAGE-SCU SOP Classes Association Policies General Number of Associations Asynchronous Nature Implementation Identifying Information Association Initiation Policy Activity Send Request Description and Sequencing of Activities Proposed Presentation Contexts Extended Negotiation SOP Specific Conformance SOP Specific Conformance for Verification SOP Class SOP Specific Conformance to SOP Classes SOP Specific Conformance for Commitment Push Model (N-ACTION) Page 7

8 Association Acceptance Policy Activity Receive N-Event Report Request Description and Sequencing of Activities Accepted Presentation Contexts Extended Negotiation SOP Specific Conformance SOP Specific Conformance to Commitment SOP Class Presentation Context Acceptance Criterion Transfer Syntax Selection Policies FIND-SCU SOP Classes Association Policies General Number of Associations Asynchronous Nature Implementation Identifying Information Association Initiation Policy Activity Query Remote AE Description and Sequencing of Activities Proposed Presentation Contexts Extended Negotiation SOP Specific Conformance SOP Specific Conformance to C-FIND SOP Classes Association Acceptance Policy MOVE-SCU SOP Classes Association Policies General Number of Associations Asynchronous Nature Implementation Identifying Information Association Initiation Policy Activity Retrieve From Remote AE Description and Sequencing of Activities Proposed Presentation Contexts...43 Page 8

9 Extended Negotiation SOP Specific Conformance SOP Specific Conformance to C-MOVE SOP Classes Association Acceptance Policy Print SCU SOP Classes Association Establishment Policy General Number of Associations Asynchronous Nature Implementation Identifying Information Association Initiation Policy Activity Film Images Description and Sequencing of Activities Proposed Presentation Contexts Common SOP Specific Conformance for all Print SOP Classes SOP Specific Conformance for the Printer SOP Class Printer SOP Class Operations (N-GET) SOP Specific Conformance for the Film Session SOP Class Film Session SOP Class Operations (N-CREATE) Film Session SOP Class Operations (N-ACTION) Film Session SOP Class Operations (N-DELETE) SOP Specific Conformance for the Presentation LUT SOP Class Presentation LUT SOP Class Operations (N-CREATE) SOP Specific Conformance for the Film Box SOP Class Film Box SOP Class Operations (N-CREATE) Film Box SOP Class Operations (N-ACTION) Film Box SOP Class Operations (N-DELETE) SOP Specific Conformance for the Basic Grayscale Image Box SOP Class Basic Grayscale Image Box SOP Class Operations (N-SET) SOP Specific Conformance for the Basic Color Image Box SOP Class Basic Color Image Box SOP Class Operations (N-SET) Association Acceptance Policy...60 Page 9

10 4.3 Physical Network Interfaces Supported Communications Stacks TCP/IP Stack Physical Network Interface Additional Protocols Configuration AE Title/Presentation Address Mapping Local AE Titles Remote AE Title/Presentation Address Mapping Parameters MEDIA Implementation Model Application Data Flow Functional Definitions of AE s MEDIA-FSR MEDIA-FSC MEDIA-FSU Sequencing of Real-World Activities AE Specifications Application Entity Specifications File Meta Information Media Application Profiles Augmented and Private Profiles Augmented Profiles Private Profiles Configuration SUPPORT OF EXTENDED CHARACTER SETS SECURITY Security Profiles Association level security Application level security ANNEXES IOD Contents Created SOP Instances Usage of attributes from received IOD s Attribute Mapping...69 Page 10

11 8.1.4 Coerced/Modified fields Data Dictionary of Private Attributes Coded Terminology and Templates Grayscale Image Consistency Standard Extended/Specialized/Private SOP Classes Private Transfer Syntaxes...69 Page 11

12 3 INTRODUCTION 3.1 Revision History Document Version Date of Issue Author Description 4.0 February 9, 2005 M. Kobayashi Revised per DICOM 2004 Part Audience This document is intended for hospital staff, health system integrators, software designers or implementers. It is assumed that the reader has a working understanding of DICOM. 3.3 Remarks DICOM, by itself, does not guarantee interoperability. However, the Conformance Statement facilitates a first-level validation for interoperability between different applications supporting the same DICOM functionality. This Conformance Statement is not intended to replace validation with other DICOM equipment to ensure proper exchange of information intended. The scope of this Conformance Statement is to facilitate communication between the POP-Net Essential and other DICOM systems. The Conformance Statement should be read and understood in conjunction with the DICOM Standard [DICOM]. However, by itself it is not guaranteed to ensure the desired interoperability and a successful interconnectivity. The user should be aware of the following important issues: The comparison of different Conformance Statements is the first step towards assessing interconnectivity between POP-Net Essential and other DICOM conformant equipment. Test procedures should be defined to validate the desired level of connectivity. Page 12

13 3.4 Abbreviations and Acronyms: AE CR CT DICOM IE IOD ISO MR PDU SC SCP SCU SOP SR TCP/IP UID US VM VL VR Application Entity Computerized Radiography Computerized Tomography Digital Imaging and Communications in Medicine Information Entity Information Object Definition International Standards Organization Magnetic Resonance Protocol Data Unit Secondary Capture Service Class Provider Service Class User Service-Object Pair Structured Reporting Transmission Control Protocol/Internet Protocol Unique Identifier Ultrasound Value Multiplicity Visible Light Value Representation Page 13

14 4 NETWORKING 4.1 Implementation Model Application Data Flow Local User requests Send STORAGE-SCU Application Entity Requested Images Received by Remote Application Entity Local User requests Print PRINT-SCU Application Entity Requested Images Received by Remote Application Entity Local User requests Query FIND-SCU Application Entity Remote Application Entity Receives Query or Retrieve Command Local User requests Retrieval MOVE-SCU Application Entity Remote Application Entity Receives Query or Retrieve Command STORAGE-SCP Application Entity Unsolicited or Requested Instances Sent by Remote Application Entity ECHO-SCP Application Entity Verification Requested by Remote Application Entity DICOM Standard Interface Figure IMPLEMENTATION MODEL POP-Net Essential is a single Windows XP application that provides both a user interface, internal database and network listener that spawns additional threads as necessary to handle incoming connections, as well as media support. Conceptually the network services may be modeled as the following separate AEs, though in fact all the AEs share a single (configurable) AE Title: ECHO-SCP, which responds to verification requests STORAGE-SCP, which receives incoming images and other composite instances STORAGE-SCU, which sends outbound images and other composite instances FIND-SCU, which queries remote AEs for lists of studies, series and instances MOVE-SCU, which retrieves selected studies, series or instances Page 14

15 PRINT-SCU, which sends outbound images and other composite instances to a printing device Functional Definitions of AE s ECHO-SCP ECHO-SCP waits in the background for connections, will accept associations with Presentation Contexts for SOP Class of the Verification Service Class, and will respond successfully to echo requests STORAGE-SCP STORAGE-SCP waits in the background for connections, will accept associations with Presentation Contexts for SOP Classes of the Service Class, and will store the received instances to the local database where they may subsequently be listed and viewed through the user interface STORAGE-SCU STORAGE-SCU is activated through the user interface when a user selects instances from the local database or a DICOMDIR, or the currently displayed instance, and requests that they be sent to a remote AE (selected from a pre-configured list) FIND-SCU FIND-SCU is activated through the user interface when a user selects a remote AE to query (from a pre-configured list), then initiates a query. Queries are performed recursively from the study through the series and instance levels until all matching instances have been listed MOVE-SCU MOVE-SCU is activated through the user interface when a user selects a study, series or instance for retrieval. A connection to the remote AE is established to initiate and monitor the retrieval and the STORAGE-SCP AE receives the retrieved instances PRINT-SCU PRINT-SCU is activated through the user interface when a user selects instances from the currently displayed instances, and requests that they be printed by a remote AE (selected from a pre-configured list). Page 15

16 4.1.3 Sequencing of Real-World Activities All SCP activities are performed asynchronously in the background and not dependent on any sequencing. All SCU activities are sequentially initiated in the user interface, and another activity may not be initiated until the prior activity has completed. Page 16

17 4.2 AE Specifications ECHO-SCP SOP Classes ECHO-SCP provides Standard Conformance to the following SOP Class: Table SOP CLASSES SUPPORTED BY ECHO-SCP SOP Class Name SOP Class UID SCU SCP Verification SOP Class No Yes Association Policies General ECHO-SCP accepts but never initiates associations. Table MAXIMUM PDU SIZE RECEIVED AS A SCP FOR ECHO-SCP Maximum PDU size received 64k bytes Number of Associations Table NUMBER OF ASSOCIATIONS AS A SCP FOR ECHO-SCP Maximum number of simultaneous associations Asynchronous Nature ECHO-SCP will only allow a single outstanding operation on an Association. All Association requests must be completed and acknowledged before a new operation can be initiated Implementation Identifying Information Table DICOM IMPLEMENTATION CLASS AND VERSION FOR ECHO-SCP Implementation Class UID Implementation Version Name EBM_DICOM_ Association Initiation Policy ECHO-SCP does not initiate associations. Page 17

18 Association Acceptance Policy If the Called AE Title does not match the pre-configured AE Title shared by all the SCPs of POP-Net Essential, the association may be rejected Activity Receive Echo Request Description and Sequencing of Activities The ECHO-SCP AE accepts Associations only if they have valid Presentation Contexts. If ECHO-SCP AE receives an echo (C-ECHO) request then the response(s) will be sent over the same Association used to send the C-ECHO-RQ Accepted Presentation Contexts Table ACCEPTABLE PRESENTATION CONTEXTS FOR ECHO-SCP AND RECEIVE ECHO REQUEST Presentation Context Table Abstract Syntax Transfer Syntax Role Extended Name UID Name UID Negotiation Verification Implicit VR Little Endian SCP None Verification Explicit VR Little Endian SCP None Extended Negotiation No extended negotiation is performed SOP Specific Conformance SOP Specific Conformance to Verification SOP Class ECHO-SCP provides standard conformance to the Verification Service Class Presentation Context Acceptance Criterion ECHO-SCP will always accept any Presentation Context for the supported SOP Classes with the supported Transfer Syntaxes. More than one proposed Presentation Context will be accepted for the same Abstract Syntax if the Transfer Syntax is supported, whether or not it is the same as another Presentation Context Transfer Syntax Selection Policies If multiple Transfer Syntaxes are proposed per Presentation Context, then only the first supported Transfer Syntax is accepted. Page 18

19 4.2.2 STORAGE-SCP SOP Classes STORAGE-SCP provide Standard Conformance to the following SOP Class(es): Table SOP CLASSES SUPPORTED BY STORAGE-SCP SOP Class Name SOP Class UID SCU SCP Computed Radiography Image No Yes Digital X-Ray Image For Presentation Digital X-Ray Image For Processing Digital Mammography X-Ray Image For Presentation Digital Mammography X-Ray Image For Processing Digital Intra-oral X-Ray Image For Presentation Digital Intra-oral X-Ray Image For Processing No Yes No Yes No Yes No Yes No Yes No Yes CT Image No Yes Enhanced CT Image No Yes US Multi-frame (Retired) No Yes US Multi-frame No Yes MR Image No Yes Enhanced MR Image No Yes MR Spectroscopy No Yes Nuclear Medicine Image (Retied) No Yes US Image (Retired) No Yes US Image No Yes Secondary Capture Image No Yes Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image Multi-frame True Color Secondary Capture Image No Yes No Yes No Yes Standalone Overlay No Yes Standalone Curve No Yes Page 19

20 12-lead ECG Waveform No Yes General ECG Waveform Strage No Yes Ambulatory ECG Waveform No Yes Hemodynamic Waveform No Yes Cardiac Electrophysiology Waveform Basic Voice Audio Waveform No Yes No Yes Standalone Modality LUT No Yes Standalone VOI LUT No Yes Grayscale Softcopy Presentation State No Yes X-Ray Angiographic Image No Yes X-Ray Radiofluoroscopic Image X-Ray Angiographic Bi-Plane Image (Retired) No Yes No Yes Nuclear Medicine Image No Yes VL Endoscopic Image No Yes Video Endoscopic Image No Yes VL Microscopic Image No Yes Video Microscopic Image No Yes VL Slide-Coordinates Microscopic Image No Yes VL Photographic Image No Yes Video Photometric Image No Yes Opthalmic Photography 8 Bit Image Opthalmic Photography 16 Bit Image No Yes No Yes Basic Text SR No Yes Enhanced SR No Yes Comprehensive SR No Yes Mammography CAD SR No Yes Key Object Selection Document No Yes Chest CAD SR No Yes Positron Emission Tomography Image No Yes RT Image No Yes Page 20

21 Association Policies General STORAGE-SCP accepts but never initiates associations. Table MAXIMUM PDU SIZE RECEIVED AS A SCP FOR STORAGE-SCP Maximum PDU size received 64k bytes Number of Associations Table NUMBER OF ASSOCIATIONS AS A SCP FOR STORAGE-SCP Maximum number of simultaneous associations Asynchronous Nature STORAGE-SCP will only allow a single outstanding operation on an Association. All Association requests must be completed and acknowledged before a new operation can be initiated Implementation Identifying Information Table DICOM IMPLEMENTATION CLASS AND VERSION FOR STORAGE-SCP Implementation Class UID Implementation Version Name EBM_DICOM_ Association Initiation Policy STORAGE-SCP does not initiate associations Association Acceptance Policy The STORAGE-SCP AE accepts Associations only if they have valid Presentation Contexts. If the Called AE Title does not match the pre-configured AE Title shared by all the SCPs of POP-Net Essential, the association may be rejected Activity Receive Request Description and Sequencing of Activities As instances are received they are copied to the local file system and a record inserted into the local database. If the received instance is a duplicate of a previously received instance, the old file and database record will be overwritten Page 21

22 with the new one Accepted Presentation Contexts Table ACCEPTABLE PRESENTATION CONTEXTS FOR STORAGE-SCP AND RECEIVE STORAGE REQUEST Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg. Name UID Table Computed Radiography SCP None Image Digital X-Ray Image For Presentation Digital X-Ray Image For Processing Digital Mammography X-Ray Image For Presentation Digital Mammography X-Ray Image For Processing Digital Intra-oral X-Ray Image For Presentation Digital Intra-oral X-Ray Image For Processing SCP None SCP None SCP None SCP None SCP None SCP None CT Image SCP None Enhanced CT Image SCP None US Multi-frame (Retired) SCP None US Multi-frame SCP None MR Image SCP None Enhanced MR Image SCP None MR Spectroscopy SCP None Nuclear Medicine Image (Retied) SCP None US Image (Retired) SCP None US Image SCP None Secondary Capture Image SCP None Page 22

23 Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image Multi-frame True Color Secondary Capture Image Presentation Context Table Abstract Syntax Transfer Syntax Role Ext. Neg SCP None SCP None SCP None Standalone Overlay SCP None Standalone Curve SCP None 12-lead ECG Waveform General ECG Waveform Strage Ambulatory ECG Waveform Hemodynamic Waveform Cardiac Electrophysiology Waveform Basic Voice Audio Waveform Standalone Modality LUT SCP None SCP None SCP None SCP None SCP None SCP None SCP None Standalone VOI LUT SCP None Grayscale Softcopy Presentation State X-Ray Angiographic Image X-Ray Radiofluoroscopic Image X-Ray Angiographic Bi-Plane Image (Retired) Nuclear Medicine Image VL Endoscopic Image Video Endoscopic Image SCP None SCP None SCP None SCP None SCP None SCP None SCP None Page 23

24 VL Microscopic Image Presentation Context Table Abstract Syntax Video Microscopic Image VL Slide-Coordinates Microscopic Image VL Photographic Image Video Photometric Image Opthalmic Photography 8 Bit Image Opthalmic Photography 16 Bit Image Transfer Syntax Role Ext. Neg SCP None SCP None SCP None SCP None SCP None SCP None SCP None Basic Text SR SCP None Enhanced SR SCP None Comprehensive SR SCP None Mammography CAD SR SCP None Key Object Selection Document SCP None Chest CAD SR SCP None Positron Emission Tomography Image SCP None RT Image SCP None TRANSFER SYNTAX COMBINATION FOR NON-IMAGE STORAGE SOP CLASSES Transfer Syntax Name UID Implicit VR Little Endian Explicit VR Little Endian Page 24

25 TRANSFER SYNTAX COMBINATION FOR IMAGE STORAGE SOP CLASSES Transfer Syntax Name UID Implicit VR Little Endian Explicit VR Little Endian JPEG 8 Bit Image Compression JPEG 12 Bit Image Compression JPEG Lossless Image Compression JPEG 2000 Image Compression (Lossless Only) JPEG 2000 Image Compression RLE Lossless Extended Negotiation No extended negotiation is performed, though STORAGE-SCP: is a Level 2 SCP (Full does not discard any data elements) does not support digital signatures does not coerce any received data elements SOP Specific Conformance SOP Specific Conformance to SOP Classes STORAGE-SCP provides standard conformance to the Service Class. When displaying an image in the viewing application, the newest Grayscale Softcopy Presentation State containing references to the image will be automatically applied and the GSPS Presentation Label and Presentation description will be displayed in the status bar. The user has the option to select any other Presentation States that also references the image. If no Presentation State references the image then no Presentation State will be applied by default. The Mask Subtraction transformation contained in Mask Subtraction Sequence (0028,6100) in Presentation State is also supported. Grayscale images in all of the Image SOP Classes listed in Table are supported as references from instances of the Grayscale Softcopy Presentation State SOP Class Presentation Context Acceptance Criterion STORAGE-SCP will always accept any Presentation Context for the supported SOP Classes with the supported Transfer Syntaxes. More than one proposed Presentation Context will be accepted for the same Abstract Syntax, if the Transfer Syntax is Page 25

26 supported, whether or not it is the same as another Presentation Context Transfer Syntax Selection Policies If offered a choice of Transfer Syntaxes in a Presentation Context, it will apply the following priority to the choice of Transfer Syntax: a. First encountered Transfer Syntax, if it is one of the Transfer Syntax s listed in Table or b. DICOM default Transfer Syntax, which is Implicit VR Little Endian. STORAGE-SCP will accept duplicate Presentation Contexts, that is, if it is offered multiple Presentation Contexts, each of which offers acceptable Transfer Syntaxes, it will accept all Presentation Contexts, applying the same priority for selecting a Transfer Syntax for each Response Status STORAGE-SCP will behave as described in Table when generating the C-STORE response command message. Table RESPONSE STATUS FOR STORAGE-SCP AND RECEIVE STORAGE REQUEST Service Status Further Meaning Error Code Behavior Success Success 0000 The Composite SOP Instance was successfully received. Refused Error Out of Resources Data Set does not match SOP Class A700 A900 Indicates that there was not enough disk space to store the image or resource to process storage. Indicates that the Data Set does not encode a valid instance of the SOP Class specified. This status is returned if the DICOM Object stream can be successfully parsed but does not contain values for one or more mandatory Elements of the SOP Class. Page 26

27 4.2.3 STORAGE-SCU SOP Classes STORAGE-SCU provide Standard Conformance to the following SOP Class(es): Table SOP CLASSES SUPPORTED BY STORAGE-SCU SOP Class Name SOP Class UID SCU SCP Verification Yes No Commitment Push Model Yes No Computed Radiography Image Yes No Digital X-Ray Image For Presentation Digital X-Ray Image For Processing Digital Mammography X-Ray Image For Presentation Digital Mammography X-Ray Image For Processing Digital Intra-oral X-Ray Image For Presentation Digital Intra-oral X-Ray Image For Processing Yes No Yes No Yes No Yes No Yes No Yes No CT Image Yes No Enhanced CT Image Yes No US Multi-frame (Retired) Yes No US Multi-frame Yes No MR Image Yes No Enhanced MR Image Yes No MR Spectroscopy Yes No Nuclear Medicine Image (Retied) Yes No US Image (Retired) Yes No US Image Yes No Secondary Capture Image Yes No Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image Multi-frame True Color Secondary Capture Image Yes No Yes No Yes No Page 27

28 Standalone Overlay Yes No Standalone Curve Yes No 12-lead ECG Waveform Yes No General ECG Waveform Strage Yes No Ambulatory ECG Waveform Yes No Hemodynamic Waveform Yes No Cardiac Electrophysiology Waveform Basic Voice Audio Waveform Yes No Yes No Standalone Modality LUT Yes No Standalone VOI LUT Yes No Grayscale Softcopy Presentation State Yes No X-Ray Angiographic Image Yes No X-Ray Radiofluoroscopic Image X-Ray Angiographic Bi-Plane Image (Retired) Yes No Yes No Nuclear Medicine Image Yes No VL Endoscopic Image Yes No Video Endoscopic Image Yes No VL Microscopic Image Yes No Video Microscopic Image Yes No VL Slide-Coordinates Microscopic Image Yes No VL Photographic Image Yes No Video Photometric Image Yes No Opthalmic Photography 8 Bit Image Opthalmic Photography 16 Bit Image Yes No Yes No Basic Text SR Yes No Enhanced SR Yes No Comprehensive SR Yes No Mammography CAD SR Yes No Key Object Selection Document Yes No Chest CAD SR Yes No Positron Emission Tomography Image Yes No RT Image Yes No Page 28

29 Association Policies General STORAGE-SCU initiates and accepts associations. Table MAXIMUM PDU SIZE RECEIVED AS A SCP FOR STORAGE-SCU Maximum PDU size received 64k bytes Number of Associations Table NUMBER OF ASSOCIATIONS AS A SCP FOR STORAGE-SCU Maximum number of simultaneous Associations proposed by STORAGE-SCU Maximum number of simultaneous Associations requested by peer AEs Asynchronous Nature STORAGE-SCU will only allow a single outstanding operation on an Association. Therefore, STORAGE-SCU will not perform asynchronous operations window negotiation Implementation Identifying Information Table DICOM IMPLEMENTATION CLASS AND VERSION FOR STORAGE-SCU Implementation Class UID Implementation Version Name EBM_DICOM_ Association Initiation Policy STORAGE-SCU attempts to initiate a new association for each instance it attempts to transfer Activity Send Request Description and Sequencing of Activities For each instance selected from the user interface to be transferred, a single attempt will be made to transmit it to the selected remote AE. If the send fails, for whatever reason, no retry will be performed, and an attempt will be made to send the next instance. Page 29

30 Proposed Presentation Contexts Table Proposed Presentation Contexts by the STORAGE-SCU AE Presentation Context Table Abstract Syntax Transfer Syntax Name UID Table Role Ext. Neg. Verification SCU None Commitment Push SCU None Model Computed Radiography Image Digital X-Ray Image For Presentation Digital X-Ray Image For Processing Digital Mammography X-Ray Image For Presentation Digital Mammography X-Ray Image For Processing Digital Intra-oral X-Ray Image For Presentation Digital Intra-oral X-Ray Image For Processing SCU None SCU None SCU None SCU None SCU None SCU None SCU None CT Image SCU None Enhanced CT Image US Multi-frame (Retired) SCU None SCU None US Multi-frame SCU None MR Image SCU None Enhanced MR Image SCU None MR Spectroscopy SCU None Nuclear Medicine Image (Retied) SCU None US Image (Retired) SCU None US Image SCU None Page 30

31 Secondary Capture Image Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image Multi-frame True Color Secondary Capture Image Standalone Overlay Abstract Syntax Presentation Context Table Transfer Syntax SCU None SCU None SCU None SCU None SCU None Standalone Curve SCU None 12-lead ECG Waveform General ECG Waveform Strage Ambulatory ECG Waveform Hemodynamic Waveform Cardiac Electrophysiology Waveform Basic Voice Audio Waveform Standalone Modality LUT Standalone VOI LUT Grayscale Softcopy Presentation State X-Ray Angiographic Image X-Ray Radiofluoroscopic Image X-Ray Angiographic Bi-Plane Image (Retired) Nuclear Medicine Image SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None Page 31

32 VL Endoscopic Image Video Endoscopic Image VL Microscopic Image Video Microscopic Image VL Slide-Coordinates Microscopic Image VL Photographic Image Video Photometric Image Opthalomic Photography 8 Bit Image Opthalomic Photography 16 Bit Image Abstract Syntax Presentation Context Table Transfer Syntax SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None SCU None Basic Text SR SCU None Enhanced SR SCU None Comprehensive SR SCU None Mammography CAD SR SCU None Key Object Selection Document SCU None Chest CAD SR SCU None Positron Emission Tomography Image SCU None RT Image SCU None Page 32

33 Table TRANSFER SYNTAX COMBINATION FOR NON-IMAGE STORAGE SOP CLASSES Transfer Syntax Name UID Implicit VR Little Endian Explicit VR Little Endian Table TRANSFER SYNTAX COMBINATION FOR IMAGE STORAGE SOP CLASSES Transfer Syntax Name UID Implicit VR Little Endian Explicit VR Little Endian JPEG 8 Bit Image Compression JPEG 12 Bit Image Compression JPEG Lossless Image Compression JPEG 2000 Image Compression (Lossless Only) JPEG 2000 Image Compression RLE Lossless STORAGE-SCU will propose Presentation Contexts only for the SOP Class of the instance that is to be transferred. For that SOP Class, STORAGE-SCU will propose a single Presentation Context with one or two Transfer Syntaxes. The first Transfer Syntax proposed is identical to the Transfer Syntax in which the instance is being stored on the local storage. If it is not Implicit VR Little Endian, STORAGE-SCU proposes DICOM default Transfer Syntax, Implicit VR Little Endian, as the second Transfer Syntax Extended Negotiation No extended negotiation is performed SOP Specific Conformance SOP Specific Conformance for Verification SOP Class Standard conformance is provided to the DICOM Verification Service Class as an SCU. The Verification Service as an SCU is actually only supported as a diagnostic service tool for network communication issues SOP Specific Conformance to SOP Classes STORAGE-SCU provides standard conformance to the Service Class. Page 33

34 Service Status TABLE STORAGE-SCU AE C-STORE Response Status Handling Behavior Further Meaning Error Code Behavior Success Success 0000 The SCP has successfully stored the exported SOP Instance. Refused Error Warning Out of Resources Data Set does not match SOP Class Cannot Understand Coercion of Data Elements Data Set does not match SOP Class Elements Discarded Attribute List Error Attribute Value Out of Range A700 A7FF A900 A9FF C000 - CFFF B000 B007 B006 * * Any other status code. This is treated as a permanent Failure. This is treated as a permanent Failure. This is treated as a permanent Failure. Image transmission is considered successful with warning. Image transmission is considered successful with warning. Image transmission is considered successful with warning Image transmission is considered successful with warning Image transmission is considered successful with warning. This is treated as a permanent Failure SOP Specific Conformance for Commitment Push Model (N-ACTION) STORAGE-SCU can request storage commitment for instances of Image SOP Class and Grayscale Softcopy Presentation State SOP Class, if user indicates request for it though user interface and the Remote AE accepts presentation context for the Commitment Push Model. STORAGE-SCU does not send the optional Media File Set ID and UID Attributes or the Referenced Study Component Sequence Attribute in the N-ACTION. The behavior of AE when encountering status codes in a N-ACTION response is summarized in the Table below. Page 34

35 Service Status Table STORAGE COMMITMENT N-ACTION RESPONSE STATUS HANDLING BEHAVIOR Further Meaning Error Code Behavior Success Success 0000 The request for storage comment is considered successfully sent. * * Any other status code. The Association is aborted using AP-ABORT Association Acceptance Policy If the Called AE Title does not match the pre-configured AE Title shared by all the SCPs of POP-Net Essential, the association may be rejected Activity Receive N-Event Report Request Description and Sequencing of Activities The STORAGE-SCU AE accepts Associations only if they have valid Presentation Contexts for Commitment Push Model SOP Class. If STORAGE-SCU AE receives a report request (N-EVENT-REPORT-RQ) then the response will be sent over the same Association used to send the N-EVENT-REPORT-RQ. STORAGE -SCU Image Manager Manager 1. Open Association 2. N-EVENT-REPORT ( Commitment Response) 3. Close Association Figure SEQUENCING OF ACTIVITY - RECEIVE STORAGE COMMITMENT RESPONSE A possible sequence of interactions between the STORAGE-SCU and an Image Manager (e.g. a storage or archive device supporting Commitment SOP Classes as an SCP) is illustrated in Figure : 1. The Image Manager opens a new association with the STORAGE-SCU. Page 35

36 2. The Image Manager sends an N-EVENT-REPORT request notifying the STORAGE-SCU of the status of a previous Commitment Request. The STORAGE-SCU replies with a N-EVENTREPORT response confirming receipt. 3. The Image Manager closes the association with the STORAGE-SCU Accepted Presentation Contexts Table ACCEPTABLE PRESENTATION CONTEXTS FOR STORAGE-SCU AND RECEIVE N-EVENT REPORT REQUEST Presentation Context Table Abstract Syntax Transfer Syntax Role Name UID Name UID Commitment Push Model Implicit VR Little Endian Explicit VR Little Endian Extended Negotiation SCU SCP Role SCU SCP Role Extended Negotiation STORAGE-SCU accepts extended negotiation for SCP Role SOP Specific Conformance SOP Specific Conformance to Commitment SOP Class STORAGE-SCU provides standard conformance to the Commitment Push Model SOP Class Presentation Context Acceptance Criterion STORAGE-SCU will always accept any Presentation Context for the supported SOP Classes with the supported Transfer Syntaxes. More than one proposed Presentation Context will be accepted for the same Abstract Syntax if the Transfer Syntax is supported, whether or not it is the same as another Presentation Context Transfer Syntax Selection Policies If multiple Transfer Syntaxes are proposed per Presentation Context, then only the first encountered and supported Transfer Syntax is accepted. Page 36

37 4.2.4 FIND-SCU SOP Classes FIND-SCU provides Standard Conformance to the following SOP Class: Table SOP CLASSES SUPPORTED BY FIND-SCU SOP Class Name SOP Class UID SCU SCP Study Root Query/Retrieve Information Model FIND Yes No Association Policies General FIND-SCU initiates but never accepts associations. Table MAXIMUM PDU SIZE RECEIVED AS A SCP FOR FIND-SCU Maximum PDU size received 64k bytes Number of Associations Table NUMBER OF ASSOCIATIONS AS A SCP FOR FIND-SCU Maximum number of simultaneous associations Asynchronous Nature FIND-SCU will only allow a single outstanding operation on an Association. Therefore, FIND-SCU will not perform asynchronous operations window negotiation Implementation Identifying Information Table DICOM IMPLEMENTATION CLASS AND VERSION FOR FIND-SCU Implementation Class UID Implementation Version Name EBM_DICOM_ Association Initiation Policy FIND-SCU attempts to initiate a new association when the user performs the query action from the user interface. If this involves recursive queries for lower query levels in the hierarchy, these will be performed on the same association. Page 37

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009 Version 7 DICOM Conformance Statement Document Version 3.02, June 2009 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of

More information

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

Version 9 DICOM Conformance Statement. Version 3.05, September 2015 Version 9 DICOM Conformance Statement Version 3.05, September 2015 1 Conformance Statement Overview The application described in this conformance statement, VEPRO EMR Manager PACS, is a collection of processes

More information

ClearCanvas Workstation DICOM Conformance Statement

ClearCanvas Workstation DICOM Conformance Statement ClearCanvas Workstation DICOM Conformance Statement Document Version: 2.1 Product Name(s): Component Name(s): Edition(s): ClearCanvas RIS/PACS ClearCanvas Workstation Chiropractic Version: 3.7 Date: July

More information

Punctual Dicom Workstation

Punctual Dicom Workstation DICOM Conformance Statement Punctual Dicom Workstation Company Name Product Name Product Version 2.0 Document number 2008-1001 Date June 1, 2009 Punctual Software Inc. Punctual Dicom Workstation TABLE

More information

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5

ClearCanvas Workstation DICOM Conformance Statement. Document Version: 1.5 ClearCanvas Workstation DICOM Conformance Statement Document Version: 1.5 Product Name(s): Release: ClearCanvas Workstation 2.0 SP1 Date: February 22, 2010 1 CONFORMANCE STATEMENT OVERVIEW 1.1 OVERVIEW

More information

Caseaccess 1.0 DICOM Conformance Statement

Caseaccess 1.0 DICOM Conformance Statement Caseaccess 1.0 DICOM Conformance Statement 1 Introduction 1.1 Integration and Features The integration of medical devices may require functions that are beyond the scope of the DICOM standard. Consequently,

More information

ClearCanvas Workstation DICOM Conformance Statement

ClearCanvas Workstation DICOM Conformance Statement ClearCanvas Workstation DICOM Conformance Statement Document Version: 3.7 Product Name(s): Component Name(s): Edition(s): ClearCanvas RIS/PACS ClearCanvas Workstation Personal Version: 13.1 Date: February

More information

Conformance Statements for DICOM PaCentric Connect / Traveler

Conformance Statements for DICOM PaCentric Connect / Traveler for DICOM Connect / Traveler Role Name / Title Signature / Date Author Svein Fimreite 21 Dec 2009 Approved Torbjørn Ånestad E-signature given by label date Document Type Engineering (ENG) Please note:

More information

DICOM 3.0 Conformance Statement

DICOM 3.0 Conformance Statement applies to Version 1.11 DICOM 3.0 Conformance Statement 1 Conformance Statement Overview SOP Classes Query and Retrieve Study Root Query/Retrieve Information Model Find Study Root Query/Retrieve Information

More information

Digital Lightbox 1.0

Digital Lightbox 1.0 Technical Publication DICOM Conformance Statement 1.0 Document Revision 1 June 3, 2008 2008 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software.

More information

Image Display DICOM Conformance Statement EasyViz 7.2

Image Display DICOM Conformance Statement EasyViz 7.2 Image Display DICOM Conformance Statement EasyViz 7.2 April 11, 2016 Document ID: 2016.04.035 Prepared By: Karos Health Table Of Contents 1. Document History... 5 2. Conformance Statement Overview... 6

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement for (Epic BP) Version 2.2.0 and later Document N. DCS2006001, Rev. 1 20 October 2006 2006 Marco Grampa - All rights reserved Page 1 1. OVERVIEW Epic Burn&Print (Epic BP) is

More information

Image Display DICOM Conformance Statement

Image Display DICOM Conformance Statement Image Display DICOM Conformance Statement EasyViz 7.5 Version 1.3 February 21, 2018 Document ID: 2017.03.006 Karos Health Incorporated 7 Father David Bauer Drive Suite 201 Waterloo, ON N2L 0A2 Canada info@karoshealth.com

More information

1 CONFORMANCE STATEMENT OVERVIEW

1 CONFORMANCE STATEMENT OVERVIEW PMOD Technologies Ltd PMOD v3.9 Version 1.0 Date: 2017.11.02 1 CONFORMANCE STATEMENT OVERVIEW This document is a DICOM Conformance statement for PMOD application version 3.9xx, where xx denotes the build

More information

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement CoActiv EXAM-PACS DICOM Conformance Statement Page 1 of 40 0. COVER PAGE CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement The information contained in this document is subject

More information

Echology Server. DICOM Conformance Statement Volume 1. <Storage and Query/Retrieve Server> Revision 1.0 Software Version 5.

Echology Server. DICOM Conformance Statement Volume 1. <Storage and Query/Retrieve Server> Revision 1.0 Software Version 5. Echology Server DICOM Conformance Statement Volume 1 Revision 1.0 Software Version 5.0 and after Date: January 17, 2008 Prepared for Page 1 Copyright 2005-2008 EBM Technologies

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001304 Page 1 of 49 AGFA HEALTHCARE DICOM Conformance Statement IMPAX Data Center 2.0 Document No. 001304 Revision: 1.1 When printed, this is NOT a controlled copy HE/001304 Page 2 of 49 Document Information

More information

DICOM Conformance Statement

DICOM Conformance Statement RADIOLOGY WORKFLOW SOLUTIONS DICOM Conformance Statement V3.11.0, 2015-10-05 Copyright 2015 medavis GmbH. All rights reserved. Software version: 3.11.0 For feedback or questions please contact: medavis

More information

Visage. DICOM Conformance Statement

Visage. DICOM Conformance Statement Visage 7 DICOM Conformance Statement Information about manufacturer and distribution contacts as well as regulatory status of the product can be found in the User Manual. Some of the specifications described

More information

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics DICOM Conformance Statement isite PACS 4.1 CREF4.09-80 2011 Nov 23 Philips Healthcare Informatics isite PACS 4.1 CREF4.09-80 2011 Nov 23 Philips Healthcare is part of Royal Philips Electronics www.medical.philips.com

More information

MediPlus TM PACS&RIS Version 2.6

MediPlus TM PACS&RIS Version 2.6 Revision 2.0, Publication #7143-202 MediPlus TM PACS&RIS Version 2.6 DICOM 3.0 Conformance Statement June 2007 Revision 2.0, Publication #7143-202 MediPlus PACS&RIS V2.6 DICOM Conformance Statement Revision

More information

DICOM Conformance Statement

DICOM Conformance Statement Rev. 10.10 DICOM Conformance Statement CPS10M10DCS005BS rev. 5 date : 14-12-2015 (d.m.y) MediMatic S.r.l. Viale Cembrano 4C 16148 Genova ITALY Notice MediMatic shall not be liable for errors contained

More information

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS PACSMail DICOM Conformance Statement Version 1.05 January 2009 Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS Telephone: 01223 421996 Web: www.sybermedica.com Email: info@sybermedica.com

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement McKesson Cardiology Release 13.2.1 June 2016 Doc ID DCM-10018 Doc Revision 1.0 Produced in Cork, Ireland Revision History Revision Revision Date Summary of Changes Rev. 1.0

More information

McKesson Radiology EXP1

McKesson Radiology EXP1 McKesson Radiology 12.1.1 EXP1 DICOM CONFORMANCE STATEMENT McKesson Technology Solutions 130 10711 Cambie Road, Richmond, BC, Canada V6X 3G5 Telephone: 604.279.5422 Toll-Free: 1-800-661-5885 Fax: 1.800.261.5432

More information

SIEMENS. DICOM Conformance Statement

SIEMENS. DICOM Conformance Statement SIEMENS Siemens Medical Solutions USA, SY CARD, Ann Arbor DICOM Conformance Statement Revision: 9.0 11-12-10 Table of Contents 1. Introduction... 4 1.1 Purpose of this Document... 4 1.2 Sources for this

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001391 Page 1 of 51 AGFA HEALTHCARE DICOM Conformance Statement IMPAX EE Server version 2.17.0 PR01 When printed, this is NOT a controlled document. HE/001391 Page 2 of 51 Document Information Service-related

More information

VM PACS DICOM Conformance Statement

VM PACS DICOM Conformance Statement VM PACS DICOM Conformance Statement Visual Medica 06/06/2014 1 Content 1. INTRODUCTION... 4 1.1. Conformance Statement Overview... 4 1.2. Field of Application... 5 1.3. References and Definitions... 6

More information

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement Document Revision 1 November 17, 2009 2009 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001480.1 Page 1 of 79 AGFA HEALTHCARE DICOM Conformance Statement 2014.1 Document No. 001480.1 Revision: 1.0 When printed, this is NOT a controlled copy. HE/001480.1 Page 2 of 79 Document Information

More information

Sep, th Edition 897N101668H

Sep, th Edition 897N101668H DICOM Conformance Statement Console Advance DR-ID 300CL/700CL 800CL/900CL for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage DICOM Dose

More information

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG

Technical Publication. DICOM Conformance Statement. Patient Browser 2.1. Document Revision 2. April 13, Copyright BrainLAB AG Technical Publication DICOM Conformance Statement 2.1 Document Revision 2 April 13, 2011 2011 Copyright BrainLAB AG 1 Conformance Statement Overview This is a conformance statement for the BrainLAB software.

More information

DICOM Conformance Statement. Version: 2.X

DICOM Conformance Statement. Version: 2.X dcm4chee DICOM Conformance Statement Version: 2.X Eng. Marco Bortolozzo, A-thon s.r.l. www.a-thon.it 2 Table of Contents Preface... 6 1 Overview... 7 2 Introduction... 10 2.1 Revision History... 10 2.2

More information

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration

GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration GEMINI DICOM Conformance Statement 16 Power PET/CT Imaging System Configuration Positron Emission Tomography (PET) Technical Information Software Version 9.1 1 DICOM CONFORMANCE STATEMENT OVERVIEW 1.1

More information

ImageBroker 4.1. DICOM Conformance Statement V 1.0. As of Copyright medigration GmbH All rights reserved

ImageBroker 4.1. DICOM Conformance Statement V 1.0. As of Copyright medigration GmbH All rights reserved ImageBroker 4.1 DICOM Conformance Statement V 1.0 As of 17.07.2009 Copyright medigration GmbH All rights reserved medigration GmbH, Schuhstr. 30, 91052 Erlangen Tel: +49 (0) 9131/69087-40, Fax: +49 (0)

More information

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010

Technical Publication. DICOM Conformance Statement. Trauma 3.0. Document Revision 2. October 5 th, 2010 Technical Publication DICOM Conformance Statement 3.0 Document Revision 2 October 5 th, 2010 2010 Copyright BrainLAB AG October 6, 2010 Document Revision 1 Page 1 of 23 1 Conformance Statement Overview

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement Page 1 of 77 AGFA HEALTHCARE DICOM Conformance Statement IMPAX 6.4 Solution Document No. 001264 Revision: 1.1 When printed, this is NOT a controlled document. Page 2 of 77 Document Information Service-related

More information

Inobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x

Inobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x Inobitec DICOM Server (PACS) Conformance Statement Version: 1.4.x Table of Contents Preface...3 1. Overview...4 2. Introduction...6 2.1 Revision History...6 2.2 Audience...6 2.3 Definitions...6 2.4 References...6

More information

Medical Imaging Consultants, Inc.

Medical Imaging Consultants, Inc. IA2000 Conformance Statement 1 Medical Imaging Consultants, Inc. Conformance Statement IA2000 Document: MICI-210-01 Revision: 6.0 Document Status: Approved When printed, this is NOT a controlled copy Reviewers

More information

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG

Technical Publication. DICOM Conformance Statement. DICOM Proxy 4.0. Document Revision 11. May 18, Copyright Brainlab AG Technical Publication DICOM Conformance Statement Document Revision 11 May 18, 2017 2017 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software

More information

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F DICOM Conformance Statement ***** FDR-1000AWS CR-IR363AWS for DICOM Storage DICOM Storage Commitment DICOM MWM DICOM MPPS DICOM Print DICOM Query / Retrieve DICOM Media Storage (Standard) August, 2010

More information

AVIA (Dx MM) DICOM 3.0 Conformance Statement

AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) DICOM 3.0 Conformance Statement AVIA (Dx MM) is a product of Medasys Digital Systems. Table of Contents 1INTRODUCTION... 4 1.1SCOPE AND AUDIENCE... 4 1.2REFERENCES... 4 1.3ACRONYMS AND ABBREVIATIONS...

More information

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED STaR DICOM Conformance Statement September 2009 Version 1.8.6 ETIAM NO COPIES PERMITTED ETIAM / DICOM STaR Version 1.8.6 DICOM Conformance Statement September 2009 Table 1: Revision History Date Version

More information

DICOM Conformance Statement Radiotherapy Document Revision 2 July 1, Copyright Brainlab AG

DICOM Conformance Statement Radiotherapy Document Revision 2 July 1, Copyright Brainlab AG Document Revision 2 July 1, 2014 2014 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab system. This system dependent from purchased licenses and

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement MOSAIC and MOSAIC HP PETView Version 9.40 Koninklijke Philips Electronics N.V. 2008 All rights are reserved. 4535 674 85871 Rev. A April 2008 DICOM Conformance Statement Issued

More information

Software Version 6.0 DICOM Conformance Statement

Software Version 6.0 DICOM Conformance Statement Software Version 6.0 DICOM Conformance Statement Related Products: PowerServer, Gateway, Gateway Router, PowerCache, RapidResults ReadFromAnywhere.com All Information provided in this document and in the

More information

DICOM Conformance Statement

DICOM Conformance Statement 10.01.80.01 Rev. 03 Customer Information Bulletin Title DICOM Conformance Statement Scope Rogan View Pro-X Target Group Service Engineers Page 2 of 2 CIB 10.01.80.01 Rev. 03 How To Contact Rogan-Delft

More information

Patterson DICOM Imaging. DICOM Conformance Statement

Patterson DICOM Imaging. DICOM Conformance Statement Patterson DICOM Imaging DICOM Conformance Statement Notice The software described in this document has been validated in accordance with the governing DICOM standard at the time of this document's release.

More information

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED

No. MIIMS0009EA DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED DICOM CONFORMANCE STATEMENT FOR MODEL TFS-3000 (MIIMS0009EA) TOSHIBA CORPORATION 2001 ALL RIGHTS RESERVED IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without

More information

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions

StellarPACS DICOM Conformance Statement. Version 1.3, August 2008 SoftTeam Solutions StellarPACS DICOM Conformance Statement Version 1.3, August 2008 SoftTeam Solutions www.softteam.com Table of Contents 1 INTRODUCTION... 3 1.1 REFERENCE... 3 1.2 DEFINITIONS... 3 1.3 ACRONYMS, ABBREVIATIONS

More information

DICOM Conformance Statement Surgery Document Revision 4 August 26, Copyright Brainlab AG

DICOM Conformance Statement Surgery Document Revision 4 August 26, Copyright Brainlab AG Document Revision 4 August 26, 2014 2014 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab system. This system dependent from purchased licenses and

More information

PACSware Migration Toolkit (MDIG)

PACSware Migration Toolkit (MDIG) PACSware Migration Toolkit (MDIG) DICOM Conformance Statement 1 MDIG DICOM Conformance Statement (061-00-0024 A) MDIG DICOM Conformance Statement.doc DeJarnette Research Systems, Inc. 401 Washington Avenue,

More information

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED Company Name: Vital Images Product Name: Vitrea Advanced Visualization 7.5 DICOM Conformance Statement Internal Document Number: VLC-09529 Rev A Date: March, 2017 COPYRIGHT 1997-2017 VITAL IMAGES, INC

More information

efx Software DICONDE Conformance Statement

efx Software DICONDE Conformance Statement efx Software DICONDE Conformance Statement Version 1.2 9/29/2015 North Star Imaging, Inc. 1 DICOM conformance statement overview The North Star Imaging s efx Software is an imaging viewing software with

More information

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED

COPYRIGHT VITAL IMAGES, INC ALL RIGHTS RESERVED Company Name: Vital Images Product Name: Vitrea Enterprise Suite V6.3 DICOM Conformance Statement Internal Document Number: VLC-07154Rev B Date: 25/04/2012 COPYRIGHT 1997-2012 VITAL IMAGES, INC ALL RIGHTS

More information

Technical Publications

Technical Publications DIRECTION 5177444-100 REV 02 Technical Publications Direction 5177444-100 Revision 02 LOGIQ e version 4.x.x for DICOM Copyright 2006 By General Electric Co. g Do not duplicate GE Ultrasound DIRECTION 5177444-100

More information

NumaLink-3.0 DICOM 3.0 Conformance Statement

NumaLink-3.0 DICOM 3.0 Conformance Statement External Distribution Revision 3 October 5, 2001 NumaLink-3.0 Revision 3 Date October 5, 2001 Author Bill Kilgore Revision History Revision Date By Comment 1 July 2, 2001 Bill Kilgore First draft 2 July

More information

Mirada XD DICOM Conformance Statement

Mirada XD DICOM Conformance Statement Mirada XD DICOM Conformance Statement mm1050-3 1 Conformance Statement Overview Mirada XD implements the necessary DICOM services to read DICOM images and other objects from the file system and save secondary

More information

iconnect Cloud Gateway V. 1.2

iconnect Cloud Gateway V. 1.2 iconnect Cloud Gateway V. 1.2 DICOM CONFORMANCE STATEMENT Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA Copyright 2017 Merge Healthcare Incorporated, an IBM Company. The content of this

More information

Technical Publications

Technical Publications Technical Publications Direction DOC0637451 Revision 1 Vivid i version 10 for DICOM Copyright 2009 By General Electric Co. g Do not duplicate GE Ultrasound THIS PAGE LEFT INTENTIONALLY BLANK TABLE OF CONTENTS

More information

Technical Publications

Technical Publications Technical Publications Direction 5141741-100 Revision 01 LOGIQ5 Expert version 4.x.x for DICOM Copyright 2005 By General Electric Co. g Do not duplicate GE Ultrasound THIS PAGE LEFT INTENTIONALLY BLANK

More information

ETIAM Nexus. DICOM Conformance Statement.

ETIAM Nexus. DICOM Conformance Statement. ETIAM Nexus DICOM Conformance Statement www.etiam.com Product Version: 5.42 Date: June 2015 ETIAM Head Office in Europe : ETIAM S.A.S.U. 2, rue du Pierre-Joseph Colin 35000 Rennes France Phone : +33.(0)2.99.14.33.88

More information

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0 DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM TM MODEL SSA-640A V5.0 TOSHIBA MEDICAL SYSTEMS CORPORATION 2015 ALL RIGHTS RESERVED Trademarks Viamo is a trademark of Toshiba Medical Systems

More information

DICOM Conformance Statement

DICOM Conformance Statement Date: 2017 10 02 DICOM Conformance Statement VideoStation Version 3.50 Softneta K. Barsausko str. 59 LT-51423 Kaunas Lithuania Page 1 of 38 1 Conformance Statement Overview VideoStation is an image acquisition

More information

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4

1 Introduction Scope and audience References Acronyms and abbreviations 3. 2 Implementation model... 4 NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet CONFORM TO ORIGINAL Revision

More information

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0 Technical Publication DICOM CONFORMANCE STATEMENT BrainLAB PatientBrowser 1.0 Revision 1.0 BrainLAB AG last change: 21.02.01 11:57 Page 1 of 12 Table of contents DICOM Conformance Statement 0. INTRODUCTION...

More information

DICOM Conformance Statement. cvi 42. Version 5.6. Workstation for Cardiovascular MR and CT

DICOM Conformance Statement. cvi 42. Version 5.6. Workstation for Cardiovascular MR and CT DICOM Conformance Statement cvi 42 Version 5.6 Workstation for Cardiovascular MR and CT 2017-02-24 CIRCLE Cardiovascular Imaging Inc Panarctic Plaza Suite 250, 815 8 th Avenue SW Calgary, Alberta, Canada

More information

Mirada XD DICOM Conformance Statement

Mirada XD DICOM Conformance Statement Mirada XD DICOM Conformance Statement mm1050-4 1 Conformance Statement Overview Mirada XD implements the necessary DICOM services to read DICOM images and other objects from the file system and save secondary

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT Document No.: S517-1087 Revision: B DAR-7500 DICOM CONFORMANCE STATEMENT MEDICAL SYSTEMS DIVISION Revision History History Date Revision Description 1 st Edition July 2007 - A July.2008 Entirely recreated.

More information

Technical Publications

Technical Publications Technical Publications Direction EP250409 Revision 21 EchoPAC PC version 5 for DICOM (From version 5.2.2) Copyright 2008 By General Electric Co. Do not duplicate GE Ultrasound THIS PAGE LEFT INTENTIONALLY

More information

Perennity AccessBox DICOM Conformance Statement

Perennity AccessBox DICOM Conformance Statement Perennity AccessBox DICOM Conformance Statement Version: 3.00 Perennity AccessBox Page 1 of 17 DICOM conformance 3.00 1. Table of contents 1. Table of contents 2 2. Preface 3 3. Perennity DICOM server

More information

Technical Publications

Technical Publications Technical Publications Direction FC250039 Revision 16 Vivid7 version 6 for DICOM Copyright 2007 By General Electric Co. g Do not duplicate GE Ultrasound THIS PAGE LEFT INTENTIONALLY BLANK TABLE OF CONTENTS

More information

Perennity DICOM edition DICOM Conformance Statement

Perennity DICOM edition DICOM Conformance Statement Perennity DICOM edition DICOM Conformance Statement Version: 4.50 Perennity DICOM edition Page 1 of 18 DICOM conformance 4.50 1. Table of contents 1. Table of contents 2 2. Preface 3 3. Introduction 4

More information

NumaStore 1.0 DICOM 3.0 Conformance Statement

NumaStore 1.0 DICOM 3.0 Conformance Statement External Distribution Revision 2 February 19, 2001 NumaStore 1.0 Revision 2 Date February 19, 2001 Author Bill Kilgore, George Panousis Revision History Revision Date By Comment 1 January 13, 2001 Bill

More information

DICOM Conformance Statement

DICOM Conformance Statement iemens syngo MR B15 XXXXXXXXXXXXxxXXXXXXXXXXXXXXXXXXXX MR 15-February-2008 Version 8.0 Siemens AG 2008 All rights reserved Siemens AG, Medical Solutions, Henkestr. 127, D-91050 Erlangen, Germany Siemensstr.

More information

RamSoft. PowerServer. DICOM Conformance Statement

RamSoft. PowerServer. DICOM Conformance Statement RamSoft PowerServer DICOM Conformance Statement PowerServer PACS DICOM Conformance Statement PowerServer PACS DICOM Conformance Statement... 2 1 Introduction... 4 2 Implementation Model... 4 2.1 Application

More information

Technical Publications

Technical Publications Technical Publications Direction DOC0913087 Revision 1.0 VOLUSON Voluson S6/S8 11.x.x Copyright 2011 by General Electric Co. Do not duplicate GE Medical Systems THIS PAGE LEFT INTENTIONALLY BLANK REVISION

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement HE/001128 Page 1 of 43 AGFA HEALTHCARE DICOM Conformance Statement IMPAX ES Release 5.2.x & 5.3.x Document No. 001128 Revision: 1.4 When printed, this is NOT a controlled copy HE/001128 Page 2 of 43 26

More information

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd.

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd. InstaPACS / InstaRISPACS / InstaViewer (v3.0.22 Release) DICOM Conformance Statement Meddiff Technologies Pvt. Ltd. Table of Contents 1. Introduction... 3 1.1 Scope and Field of Application:... 3 1.2 References

More information

Technical Publications

Technical Publications GE HEALTHCARE DIRECTION 5184517-100REV 3.0 LOGIQ A5 3.X.X Technical Publications Direction 5184517-100 Revision 3.0 LOGIQ A5 version 3.x.x for DICOM Copyright 2009 By General Electric Co. Do not duplicate

More information

Technical Publications

Technical Publications GE HEALTHCARE DIRECTION 5178040-100REV 2.0 LOGIQ P5 2.X.X Technical Publications Direction 5178040-100 Revision 2.0 LOGIQ P5 version 2.x.x for DICOM Copyright ª 2007 By General Electric Co. g Do not duplicate

More information

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract

Abstract DCV DICOM CONFORMANCE. XrayVision DCV DICOM Conformance Statement. Abstract Apteryx Inc. 313 S. High St. Suite 200 Akron, OH 44308 DCV DICOM CONFORMANCE 330-376-0889 voice 330-376-0788 fax sales@apteryx.com www.apteryx.com XrayVision DCV DICOM Conformance Statement Abstract Abstract

More information

Merge iconnect Enterprise Archive V. 9.4

Merge iconnect Enterprise Archive V. 9.4 Merge iconnect Enterprise Archive V. 9.4 DICOM CONFORMANCE STATEMENT Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA 2014 Merge Healthcare. The information contained herein is confidential

More information

DICOM Conformance Statement Product Name HCP DICOM Net Version

DICOM Conformance Statement Product Name HCP DICOM Net Version Title DICOM Conformance Statement Product Name HCP DICOM Net Version 5.00.00 Copyright - 2000-2013 SoftLink International Pvt. Ltd. SoftLink International Pvt. Ltd. Page 1 of 37 2, Anand Park, Aundh, Pune

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Vitrea Connection 7.1 April 16, 2018 Vital Images Incorporated 5850 Opus Parkway Suite 300 Minnetonka, MN USA 55343 support@vitalimages.com Vital Images shall not be liable

More information

Technical Publications

Technical Publications DIRECTION 2390126-100REV2 Technical Publications Direction 2390126-100 Revision 2 LOGIQ3 /Expert/Pro version 4.x.x for DICOM Copyright 2005 By General Electric Co. g Do not duplicate GE Ultrasound DIRECTION

More information

AG Mednet Agent DICOM Conformance Statement Version 1.3

AG Mednet Agent DICOM Conformance Statement Version 1.3 AG Mednet Agent DICOM Conformance Statement Version 1.3 AG Mednet, Inc. Page 2 CONTENTS 1 INTRODUCTION...5 1.1 REVISION HISTORY...5 1.2 AUDIENCE...5 1.3 REMARKS...5 2 NETWORKING...7 2.1 IMPLEMENTATION

More information

JiveX Web-enabled solutions for medical imagecommunication

JiveX Web-enabled solutions for medical imagecommunication JiveX Web-enabled solutions for medical imagecommunication and processing JiveX Mammo Screening Manager Conformance Statement - DICOM Version: 4.5.3 As of 2012-12-17 VISUS Technology Transfer GmbH Universitätsstr.

More information

DICOM Conformance Statement. isite PACS 3.6. CREF Apr Philips Medical Systems Radiology Informatics

DICOM Conformance Statement. isite PACS 3.6. CREF Apr Philips Medical Systems Radiology Informatics DICOM Conformance Statement isite PACS 3.6 CREF4.09-81 Apr 29 2008 Philips Medical Systems Radiology Informatics Radiology Informatics DICOM Conformance Statement isite PACS 3.6 CREF4.09-81 Apr 29 2008

More information

Application Launcher 2.2 DICOM Conformance Statement

Application Launcher 2.2 DICOM Conformance Statement Contents mm761-0 Application Launcher 2.2 DICOM Conformance Statement 1 Introduction... 3 1.1 Integration and Features... 3 1.2 Definitions... 3 2 NETWORKING... 4 2.1 Implementation Model... 4 2.1.1 Application

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement VioArchive 2.7 September 28, 2017 Vital Images Incorporated 5850 Opus Parkway Suite 300 Minnetonka, MN USA 55343 support@vitalimages.com Vital Images shall not be liable for

More information

DICOM Conformance Statement IDS5 7.2, WISE 7.2, ImageServer/s 7.2

DICOM Conformance Statement IDS5 7.2, WISE 7.2, ImageServer/s 7.2 DICOM Conformance Statement IDS5 7.2, WISE 7.2, ImageServer/s 7.2 DICOM Conformance Statement, IDS5 7.2, WISE 7.2, ImageServer/s 7.2 As part of our commitment to providing the highest quality products

More information

Documento n Revision 1.5 Dicom Conformance Statement del sistema PACS di AGFA

Documento n Revision 1.5 Dicom Conformance Statement del sistema PACS di AGFA Allegato 1A.B AZIENDA U.L.S.S. N. 20 DI VERONA FORNITURA DI UN ANGIOGRAFO FINALIZZATO ALLA RIVASCOLARIZZAZIONE POLIDISTRETTUALE - MULTIDISCIPLINARE CON ALLEGATO CAPITOLATO TECNICO PROCEDURA APERTA Documento

More information

dicom PACS 5 Version 5.2

dicom PACS 5 Version 5.2 dicompacs 5 Version 5.2 TABLE OF CONTENTS 1. Introduction... 3 1.1. Revision History... 3 1.2. Abbreviations and Acronyms... 4 2. Implementation Model... 5 2.1. Application Data Flow Diagram... 5 2.2.

More information

SecurView RT/TechMate Workstation DiCom Conformance statement

SecurView RT/TechMate Workstation DiCom Conformance statement breast imaging solutions DICOM Standard Interface SecurView RT/TechMate Workstation DiCom Conformance statement Software Version 8.4 man-03818 revision 002 SecurView RT/TechMate 8.4 Workstation DICOM

More information

DICOM Conformance Statement RT Elements Document Revision 3 January 19, Copyright Brainlab AG

DICOM Conformance Statement RT Elements Document Revision 3 January 19, Copyright Brainlab AG Document Revision 3 January 19, 2017 2017 Copyright Brainlab AG 1 Conformance Statement Overview This is a Conformance Statement for the Brainlab Radiotherapy system. This system dependent from purchased

More information

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL

More information

Health Engine DICOM Conformance Statement. Internal document number: Date:

Health Engine DICOM Conformance Statement. Internal document number: Date: Health Engine DICOM Conformance Statement Version: 1.1 Rev A Internal document number: 31011232509 Date: 20160603 the i-engineers AG June 2016 Abstract Manufacturer Support This document provides information

More information

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement Dx Server for Windows NT DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL

More information

SonoWin Picture Archiving System

SonoWin Picture Archiving System Page 1 of 12 SonoWin Picture Archiving System DICOM SSCP Module Version 4.5 DICOM Conformance Statement Page 2 of 12 Table of Contents 1 DOCUMENT HISTORY... 4 2 INTRODUCTION... 4 2.1 SOURCES OF INFORMATION...

More information