Reference Guide. Remote Control

Size: px
Start display at page:

Download "Reference Guide. Remote Control"

Transcription

1 Remote Control Reference Guide Remote control enables you to operate the buttons on the front panel of the MVS-12 from an external device. This document describes how to operate the unit remotely via MIDI, RS-232C interface, or over the LAN. Copyright 2010 ROLAND CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION. 1PS

2 Contents Connecting External Equipment...3 Connecting a Video Mixer... 3 About MIDI Setup...3 Connecting the LVS Connecting the V-1600HD...6 Connecting RS-232C devices... 7 About Baud Rate Setting...7 Connecting Network Devices... 8 About Networking Setup...8 MVS-12 Command Reference Overview of Commands...10 Commands Transmitted from External Equipment...11 Commands Transmitted from MVS MIDI Implementation Message received at MIDI IN...16 Channel Voice Message...16 System Exclusive Message...17 Message transmitted from MIDI OUT...18 System Exclusive Message...18 Parameter Address Map...18 Appendices...19 Default Settings of MIDI In/Out...21 MIDI Implementation Chart

3 Connecting External Equipment Connecting a Video Mixer You can use the MIDI OUT of a video mixer to remotely control the MVS-12. To do this, connect a MIDI cable from MIDI OUT/THRU connector of your video mixer to the MIDI IN connector of your MVS-12. About MIDI Setup To enable MIDI control, you will need to make some settings in the MVS-12 s MIDI SETUP menu. Press the [EDIT] button of [MIDI SETTING] in SYSTEM SETTING menu to open the screen below. fig.midi-setting-screen.eps\ MIDI OUT/THRU This sets the status of MVS-12's MIDI OUT/THRU connector. By default, this is set to [THRU]. When you wish to receive responses from the MVS-12, set this to [OUT]. CTRL CH This selects the channel for MIDI transmission. Set this to the same channel as the connected video mixer. DEVICE ID Set this to same value as the connected video mixer. LVS-800 ver. Set this according to the system version of the connected LVS-800. Set this to [1.0] if system version of the LVS-800 is 1.0. In this case, some functions are limited (p. 5) and a message of Works with A/B Mode only appears. If the system version of the connected LVS-800 is 1.1 or later, this value must be set to [1.1-]. If you set this to [1.0], the remote control function may not work properly. 3

4 Connecting External Equipment Connecting the LVS-800 When controlled remotely by the LVS-800 video mixer, the input select, Preview and Program status of the LVS-800 can be viewed on a video monitor connected to MULTI-OUT (MENU) connector of the MVS Connect output of the LVS-800 Connect the Monitor Outputs or the Program/Preview Outputs from the LVS-800 to the VIDEO INPUT connectors on the MVS-12. Connections shown on the chart below are recommended. fig.lvs800-in-out-connect.eps\ LVS-800 MVS-12 MONITOR OUT 1-8 VIDEO INPUT 1-8 A/B MIX PVW VIDEO INPUT 9 A/B MIX OUT VIDEO INPUT 10 PGM PVW PGM OUT VIDEO INPUT 11 VIDEO INPUT Connect the LVS-800 and the MVS-12 using MIDI Connect the MIDI output from the LVS-800 to the MIDI IN connector on the MVS-12. * By default, MIDI OUT on the LVS-800 is set to [THRU]. Change the setting to [OUT]. LVS-800 MENU > [MIDI SETUP] > [MIDI OUT/THRU SWITCH] > Select [OUT] * Set the MIDI channels and device IDs to matching values, and set the MVS-12 to receive MIDI signals from the LVS-800. MVS-12 : MAIN MENU > [SYSTEM SETTINGS] > [MIDI SETTING] LVS-800 : [MENU] > [MIDI SETUP] Make sure the settings of MIDI CH and DEVICE ID are the same on both units. * Other MIDI settings of the LVS-800 should be unchanged from default status. fig.connect-lvs-800-midi.eps MVS-12 LVS-800 4

5 Connecting External Equipment Operations on the LVS-800 and the display of MVS-12 When responding to operations on the LVS-800, the display of the MVS-12 changes as below. Preview Output Select a preview channel on LVS-800. A green box will displayed around that input s display box on the MVS-12 s output. * If you have connected LVS-800 s PGM PVW output to MVS-12 s VIDEO INPUT 11, whatever input has been selected on the preview bus will appear in the [CH 11] position of the MVS-12 s monitor. fig.pvw-output.eps Green Green Program Output When you operate the LVS-800 s video fader (T-bar) or [AUTO] button, the video you selected on the preview bus will be sent to the PGM bus and be output from the LVS-800 s PGM OUT connector. The corresponding channel box on your MVS-12 s monitor will change color from green to red to indicate that it s now live. * If you are connecting the LVS-800 s PGM OUT to the MVS-12 s VIDEO INPUT 12, the picture you selected on the LVS-800 is shown on the [CH 12] position of the monitor connected to the MVS-12. * If you select a different channel on the LVS-800 s preview bus, a green box will appear on the corresponding channel in the MVS-12 s monitor. fig.pgm-output.eps Red Red If the same channel is selected for Preview and Program, the two boxes overlap. Both boxes will go red in the MVS-12 s monitor. The red and green boxes are not displayed at multiple locations even when the MVS-12 has been set to display a single channel at multiple locations. Only a single box of each color is displayed. When the system version of the LVS-800 is 1.0, only operation in the A/B mode is supported. With system version 1.1 or later, PGM-PST mode, LVS mode and Picture in Picture are also supported. The system version of your LVS-800 mixer is displayed during startup on a monitor connected to the LVS-800 s A/B MIX PVW jack. If you activate the V-LINK of your external controller device, you can remotely select which source channel will be routed to MATRIX OUT 1 of the MVS-12. Refer to "Connecting the V-1600HD" (p. 6). If you do not wish to switch source channels from external equipment, turn V-LINK to [OFF]. 5

6 Connecting External Equipment Connecting the V-1600HD You can use the MVS-12 as a source for expanded SD video inputs to feed to the V-1600HD. In this case, the MVS-12 can be operated as a matrix switcher that is controlled remotely by the V-1600HD. 1. Connect output of the MVS-12 to the V-1600HD Connect cameras and other source devices to VIDEO INPUT 1 through 12 on the MVS-12. Connect MATRIX OUT 1 on the MVS-12 to SD IN (channel 13) on the V-1600HD. fig.coonnect-v1600hd-input.eps 2. Connect the V-1600HD and the MVS-12 using MIDI Connect the MIDI output from the V-1600HD to the MIDI IN connector on the MVS-12. * Set the MIDI channels and device IDs to matching values, and set the MVS-12 to receive MIDI signals from the V-1600HD. * Use the menu on the V-1600HD to switch on V-LINK. Select [Master Switch] in [MIDI] of SYSTEM menu and turn it to [ON]. Then turn [V-LINK Master] to [ON]. fig.connect-v1600hd-midi.eps MVS-12 V-1600HD Operations on the V-1600HD Hold down PST/EFFECT [13] and press a PGM buttons [1] through [12]. This will cause the desired MVS-12 input to route to channel 13 of the V-1600HD. PGM buttons [1] through [12] correspond to VIDEO INPUT 1 through 12 on the MVS-12. fig.opeprating-v1600hd.eps 6

7 Connecting External Equipment Connecting RS-232C devices Connect an RS-232C capable device such as a computer or touch panel to MVS-12 s RS-232C connector. This will allow you to perform panel control operations remotely. fig.connect-pc.eps\ Specifications of RS-232C Connector Transmission Format Start-stop synchronization (asynchronous), full duplex Transmission Rate 9600/19200/38400/ Parity None Data Length 8 bits Stop Bit Length 1 bit Encoding ASCII Flow Control None Here is the pin assignments of the MVS-12 s RS-232C connector. fig.pin-assign.eps\ Pin No Signal DCD RXD TXD DTR GND DSR RTS CTS RI Cable Connection MVS-12 DCD RXD TXD DTR GND DSR RTS CTS RI PC etc. DCD RXD TXD DTR GND DSR RTS CTS RI Refer to MVS-12 Command Reference (p. 10) for the commands to remote control the MVS-12. About Baud Rate Setting Press [EDIT] button of [RS-232C SETTING] in SYSTEM SETTING menu to open the screen below. You can set the baud rate in this screen. fig.baud-rate-setting.eps 7

8 Connecting External Equipment Connecting Network Devices Connect the MVS-12 to a network via a router or other network devices. You can remote control the MVS-12 from a web browser or TCP Control commands from your computer. fig.connect-network.eps\ About Networking Setup Press [EDIT] button of [NETWORK SETTING] in SYSTEM SETTING menu to open the screen below. You can set appropriate networking parameters in this screen. fig.network-screen.eps DHCP If your network has a router or other device that provides DHCP, turn this [ON] and DHCP device will automatically assign the appropriate network settings to the MVS-12. * When DHCP is turned to [ON], you cannot change IP ADDRESS, SUBNET MASK or DEFAULT GATEWAY values. CTRL PORT You can select port number (for TCP control). * When you are using the MVS-12 in a network environment, such as on a company LAN, an available port number must be assigned. Check with the network administrator to determine what port numbers are available for use. IP ADDRESS Allows you to manually assign an IP Address. SUBNET MASK Allows you to manually assign the subnet mask. DEFAULT GATEWAY Allows you to manually assign a Gateway IP address. MAC ADDRESS This displays the MAC (Media Access Control) number unique to the LAN connector of your MVS-12. 8

9 Connecting External Equipment Operations Over the Network (web browser) By typing your network-enabled MVS-12 s IP address into the address bar of a web browser, you can remotely control the units panel functions. Be sure to include the prefix. In the example, the web address is fig.browser-screen.eps\ Clicking [to Edit Mode], you can switch to the Edit Mode screen below. You can perform functions like [NAME EDIT] or [INPUT ASSIGN]. Set Name Input name and click [Input 1] through [Input 12] or [Matrix Out 1] through [Matrix Out 4]. The name you have input will be reflected to the selected channel. (You cnnot use [%] name input.) Input Assign Click a button of [Input 1] through [Input 12] on lines of 1 through 12. You can select a channel to be assigned to each Multi-Viewer window (1-12). fig.edit-screen.eps * Clicking [to Panel Mode], you can return to Panel Mode screen. Refer to "MVS-12 Command Reference"(p. 10) for TCP control. 9

10 MVS-12 Command Reference The MVS-12 can be remote controlled from external equipment like a computer via RS-232C, LAN or MIDI. Overview of Commands A command consists of an ASCII code sequence containing "stx," three uppercase letters of, and a semicolon (";"). The three letters indicate the command type. If the command has an argument, a colon (":") is inserted between the command letters and the argument. When multiple arguments occur, they are separated by commas (","). * Never use spaces in commands or arguments. * Example : stxmtx:2,0; will route Input 1 ( 0 ) to Matrix Out 3 ( 2 ). "stx" This is the ASCII code signal name (code number 02H [hexadecimal]) and code that signals the command start. * Your device s stx command may not be the ASCII letters stx or 02H. Refer to your RS-232C controller s manual to send proper command. ":" This is the code to separate the command and its argument. ";" This is the code to make MVS-12 recognize the end of a command. MVS-12 uses common commands for remote control via RS-232C, LAN (Ethernet TCP Control) and MIDI. Via RS-232C The specifications of RS-232C transmissions are as follows. Transmission Format Start-stop synchronization (asynchronous), full duplex Transmission Rate 9600/19200/38400/ bps Parity None Data Length 8 bits Stop Bit Length 1 bit Encoding ASCII Flow Control None * Refer to Specifications of RS-232C Connector (p.xx) for signal assignments to pins. Via LAN Transmission is performed using TCP via the specified PORT (50000 through 50009) under Ethernet TCP control. Via MIDI Transmission is performed using MIDI System Exclusive messages. * Connect MIDI OUT of external device to MVS-12 s MIDI IN. * If you wish to use response commands like those shown below, you need to connect MVS-12 s MIDI OUT to MIDI IN of external device. Set the MVS-12 s [MIDI OUT/THRU] to [OUT] in this case. RPS RVA RIN RMN RVN Data Byte F0H Exclusive Status 41H ID Number (Roland) dev Device ID (dev:10h-1fh) 00H MVS-12 Model ID 00H MVS-12 Model ID 4FH MVS-12 Model ID 12H Command ID (DT1) Command Data SSH Checksum F7H 10

11 MVS-12 Command Reference Commands Transmitted from External Equipment If you are sending commands from a remote device to the MVS-12, make sure the MVS-12 s menu is OFF. The MVS-12 cannot receive external commands while the menu is ON. Also, the MVS-12 may not properly understand external commands if they are sent continuously. Try to include a short interval between each remote command. The following commands can be sent to the MVS-12. They are shown in RS-232C (ASCII) and hexadecimal (MIDI). MLD : Memory Select Activate the specified memory number. stxmld:a; a : Memory Number (0-3) stx M L D : a ; O2H 4DH 4CH 44H 3AH * 3BH * = 30H-33H MSV : Memory Write Write current status to specified memory number. stxmsv:a; a : Memory Number (0-3) stx M S V : a ; O2H 4DH 53H 56H 3AH * 3BH * = 30H-33H MTX : Matrix Out Select Route an input channel to Matrix Out 1 through 4. stxmtx:a,b; a : Matrix Out (0-3) b : Input (0-9, A, B) stx M T X : a, b ; O2H 4DH 54H 58H 3AH *1 2CH *2 3BH *1 = 30H-33H *2 = 30H-39H,41H,42H MVL : Mutil-Out Layout Select Select the layout of Multi-Out. stxmvl:a; a : Multi-Out Layout (0-4) 0=Split 12, 1=Split 9, 2=Split 10, 3=Split 4 4=No Split stx M V L : a ; O2H 4DH 56H 4CH 3AH * 3BH * = 30H-33H MVA : Multi-Out Assign Select Select input for each window of multi-out layout. stxmva:a,b; a : Window Position (0-9, A, B) b : Input (0-9, A, B) stx M V A : a, b ; O2H 4DH 56H 41H 3AH * 2CH * 3BH * = 30H-39H,41H,42H 11

12 MVS-12 Command Reference INA : Naming for Inputs Set name for specified input. Fixed to 8 characters. stxina:a,nnnnnnnn; a : Input (0-9, A, B) n : Name (8 characters 20H-7EH) stx I N A : a, n n n n n n n n ; O2H 49H 4EH 41H 3AH *1 2CH *2 *2 *2 *2 *2 *2 *2 *2 3BH *1 = 30H-39H,41H,42H *2 = 20H-7EH * If the name is shorter than 8 characters, fill the remaining part with space (20H). MVS-12 automatically deletes unnecessary space. MNA : Naming for Matrix Out Set name for each matrix out. Fixed to 8 characters. stxmna:a,nnnnnnnn; a : Matrix Out (0-3) n : Name (8 characters 20H-7EH) stx M N A : a, n n n n n n n n ; O2H 4DH 4EH 41H 3AH *1 2CH *2 *2 *2 *2 *2 *2 *2 *2 3BH *1 = 30H-39H,41H,42H *2 = 20H-7EH * If the name is shorter than 8 characters, fill the remaining part with space (20H). MVS-12 automatically deletes unnecessary space. TLY : Set Tally (AB) Specify Tally AB indicator status. stxtly:a,b,c,d; a: A input number (0-9, A, B) b: A display (0-2) 0=none, 1=green, 2=red c: B input number (0-9, A, B) d: B display (0-2) 0=none, 1=green, 2=red stx T L Y : a, b, c, d ; O2H 54H 4CH 59H 3AH *1 2CH *2 2CH *1 2CH *2 3BH *1 = 30H-39H,41H,42H *2 = 30H-32H STL : Set Tally Specify Tally indicators. stxstl:a,b, c; a: TALLY(0-2) 0=A, 1=B, 2=C b: InputÅi0-9,A,B) c: Display (0-2) 0=none, 1=green, 2=red stx S T L : a, b, c ; O2H 53H 54H 4CH 3AH *1 2CH *2 2CH *1 3BH *1 = 30H-32H *2 = 30H-39H,41H,42H * You cannot use display = green when set to TALLY=C(2). 12

13 MVS-12 Command Reference RPS : Request for Status Information Returns current memory number, multi-out layout and matrix out status. stxrps; stx R P S ; O2H 52H 50H 53H 3BH Refer to IPS : Status Information in Commands Transmitted from MVS-12 for codes to be returned. RVA : Request for Multi-Out Assign Information Returns input channel information for each window of current multi-out layout. stxrva; stx R V A ; O2H 52H 56H 41H 3BH Refer to IVA : Multi-Out Assign Information in Commands Transmitted from MVS-12 for codes to be returned. RIN : Request for Names of Inputs Returns name of specified input. stxrin:a; a : Input (0-9, A, B) stx R I N : a ; O2H 52H 49H 4EH 3AH * 3BH * = 30H-39H,41H,42H Refer to IIN : Names of Inputs in Commands Transmitted from MVS-12 for codes to be returned. RMN : Request for Names of Matrix Out Returns name of specified matrix out. stxrmn:a; a : Matrix Out (0-3) stx R M N : a ; O2H 52H 4DH 4EH 3AH * 3BH * = 30H-33H Refer to IMN : Names of Matrix Out in Commands Transmitted from MVS-12 for codes to be returned. RVN : Request for Version Information Returns version information of MVS-12. stxrvn; stx R V N ; O2H 52H 56H 4EH 3BH Refer to IVN : Version Information in Commands Transmitted from MVS-12 for codes to be returned. 13

14 MVS-12 Command Reference Commands Transmitted from MVS-12 The following commands are sent from the MVS-12 to your remote device. IPS : Status Information Sends current memory number, multi-out layout and matrix out status. (response to RPS command) stxips:a,b,c,defg; a : Memory Number (0-3) b : Multi-Out Layout (0-4) c : Matrix Select (0-3) d : Matrix Out 1 (0-9, A, B) e : Matrix Out 2 (0-9, A, B) f : Matrix Out 3 (0-9, A, B) g : Matrix Out 4 (0-9, A, B) stx I P S : a, b, c, d e f g ; O2H 49H 50H 53H 3AH *1 2CH *1 2CH *1 2CH *2 *2 *2 *2 3BH *1 = 30H-33H *2 = 30H-39H,41H,42H IVA : Multi-Out Assign Information Sends input channel information for each window of current multi-out layout. (response to RVA command) stxiva:abcdefghijkl; a : Multi-out window 1 input (0-9, A, B) b : Multi-out window 2 input (0-9, A, B) c : Multi-out window 3 input (0-9, A, B) d : Multi-out window 4 input (0-9, A, B) e : Multi-out window 5 input (0-9, A, B) f : Multi-out window 6 input (0-9, A, B) g : Multi-out window 7 input (0-9, A, B) h : Multi-out window 8 input (0-9, A, B) i : Multi-out window 9 input (0-9, A, B) j : Multi-out window 10 input (0-9, A, B) k : Multi-out window 11 input (0-9, A, B) l : Multi-out window 12 input (0-9, A, B) stx I V A : a b c d ef g h i j kl ; O2H 49H 56H 41H 3AH * * * * * * * * * * * * 3BH * = 30H-39H,41H,42H IIN : Names of Inputs Sends names of inputs (response to RIN command). stxiin:a,nnnnnnnn; a: Input (0-9, A, B) n: Name (8 characters) stx I I N : a, n n n n n n n n ; O2H 49H 49H 4EH 3AH *1 2CH *2 *2 *2 *2 *2 *2 *2 *2 3BH *1 = 30H-39H,41H,42H *2 = 20H-7EH * If the name is shorter than 8 characters, remaining part is automatically filled with space (20H). 14

15 MVS-12 Command Reference IMN : Names of Matrix Out Sends names of matrix out (response to RMN command). stximn:a,nnnnnnnn; a: Matrix Out (0-3) n: Name (8 characters) stx I M N : a, n n n n n n n n ; O2H 49H 4DH 4EH 3AH *1 2CH *2 *2 *2 *2 *2 *2 *2 *2 3BH *1 = 30H-33H *2 = 20H-7EH * If the name is shorter than 8 characters, remaining part is automatically filled with space (20H). IVN : Version Information Sends version information of MVS-12 (response to RVN command). stxivn: a, b, c ; a: Model name (MVS-12) b: Version c: Reserved Version information is ASCII text string. stx I V N : a, b, c ; O2H 49H 56H 4EH 3AH * 2CH * 2CH * 3BH * = Text string using 20H-7EH 15

16 MIDI Implementation Model: MVS-12 Version: 1.00 Date: Jul Symbol Item Setting Range n: MIDI Channel 0H-FH (ch.1 - ch.16) vv: Control Value 00-7FH (0-127) Message received at MIDI IN If MIDI Thru is ON, MIDI message received at MIDI IN will be re-transmitted without change from MIDI OUT. Channel Voice Message Control Change Bank Select MSB (controller number 0) Status 2nd Byte 3rd Byte BnH 00H mmh MSB (BnH 20H llh ) LSB is ignored. Fixed to 00H. mm,ll =bank number : 00 00H - 7F 00H (bank.1 - bank.16257) * Processing of a Bank Select message is suspended until a subsequent Program Change is received. * Bank Select data that is received will be maintained until a subsequent Program Change is received. * BnH 20H llh (Bank Select LSB) is ignored. * This is received only when [LVS-800 ver.] is set to [1.0]. Controls corresponds to bank select messages are as follows Bank Select Program No. Control MSB LSB TALLY H 00H (bank.1) 00H - 0BH A-BUS.INPUT 1-12 TALLY H 00H (bank.129) 00H - 0BH B-BUS.INPUT 1-12 TALLY Expression (controller number 11) Status 2nd Byte 3rd Byte BnH 0BH vvh vv = Fader : 00H - 7FH * This is used to change color of Tally Indicators. * This is received only when [LVS-800 ver.] is set to [1.0]. Program Change Status 2nd Byte CnH pph pp = Program Number : 00H - 0BH (prog.1 - prog.12) * Refer to Bank Select items for details * When the V-LINK On is received, Program Change command works as Input Select for Matrix Out 1 (Bank Select is ignored in this case). 16

17 MIDI Implementation System Exclusive Message Exclusive Message of MVS-12 (Model ID = 00H 00H 4FH) Byte Explanation F0H 41H dev 00H 00H 4FH 12H Exclusive Status ID Number (Roland) Device ID (dev:10h-1fh) Upper Byte of Model ld (MVS-12) Model ld (MVS-12) Lower Byte of Model ld (MVS-12) Command ID (DT1) aah : nnh Actual Data : Tally Information, Remote Command SSHChecksum F7H V-LINK ON/OFF (Model ID = 00H 51H) Byte Explanation F0H 41H dev 00H 51H 12H Exclusive Status ID Number (Roland) Device ID (dev:10h-1fh) Upper Byte of Model ID (V-LINK message) Lower Byte of Model ID (V-LINK message) Command ID (DT1) 10H 00H 00H aah SSH F7H V-LINK Enable address - Upper V-LINK Enable address V-LINK Enable address - Lower 00H=off, 01H=on Checksum * When the V-LINK On is received, Program Change command works as Input Select for Matrix Out 1 (Bank Select is ignored in this case). * The address or data other than V-LINK On will be ignored. Refer to Exclusive message examples and checksum calculation (p. 20) for data and checksum. The MVS-12 cannot operate properly if you continuously transmit data without appropriate intervals. 17

18 MIDI Implementation Message transmitted from MIDI OUT If MIDI Out/Thru is Thru, MIDI messages received at MIDI IN will be re-transmitted without change from MIDI OUT. The exclusive messages of MVS-12 will not be transmitted. System Exclusive Message Exclusive Message of MVS-12 (Model ID = 00H 00H 4FH) Byte Explanation F0H Exclusive Status 41H ID Number (Roland) dev Device ID (dev:10h-1fh) 00H Upper Byte of Model ld (MVS-12) 00H Model ld (MVS-12) 4FH Lower Byte of Model ld (MVS-12) 12H Command ID (DT1) aah : nnh SSH F7H Actual data : Remote command Checksum Parameter Address Map MIDI Exclusive Address Map Start Address Description H 00H 00H TALLY Indicator 00H 00H 05H H 00H 06H reserved : 01H 7fH 7fH H Control Command H 00H 00H reserved : 7fH 7fH 7fH TALLY Indicator * 00H 00H 00H TALLY A input# 00H-0BH 00H 00H 01H color 00H-03H 0=off, 1=Green, 2=Red, 3=ignore * 00H 00H 02H TALLY B input# 00H-0BH 00H 00H 03H color 00H-03H 0=off, 1=Green, 2=Red, 3=ignore * 00H 00H 04H TALLY C input# 00H-0BH 00H 00H 05H color 00H-03H 0=off, (1=off), 2=Red, 3=ignore * The addresses with asterisks can be set. * The input # and color specification must be combined as a data to transmit. The data length must be even numbered. Control Commands Control commands start with 02H(stx). Refer to MVS-12 Command Reference (p. 10). 18

19 MIDI Implementation Appendices Decimal and hexadecimal conversion table (The letter H follows numbers in hexadecimal notation.) MIDI uses hexadecimal notation in 7-bit units to indicate data values, addresses and sizes within an exclusive message. Hexadecimal and decimal numbers corresponds as follows. Deci Hexa Deci Hexa Deci Hexa Deci Hexa 0 00H 32 20H 64 40H 96 60H 1 01H 33 21H 65 41H 97 61H 2 02H 34 22H 66 42H 98 62H 3 03H 35 23H 67 43H 99 63H 4 04H 36 24H 68 44H H 5 05H 37 25H 69 45H H 6 06H 38 26H 70 46H H 7 07H 39 27H 71 47H H 8 08H 40 28H 72 48H H 9 09H 41 29H 73 49H H 10 0AH 42 2AH 74 4AH 106 6AH 11 0BH 43 2BH 75 4BH 107 6BH 12 0CH 44 2CH 76 4CH 108 6CH 13 0DH 45 2DH 77 4DH 109 6DH 14 0EH 46 2EH 78 4EH 110 6EH 15 0FH 47 2FH 79 4FH 111 6FH 16 10H 48 30H 80 50H H 17 11H 49 31H 81 51H H 18 12H 50 32H 82 52H H 19 13H 51 33H 83 53H H 20 14H 52 34H 84 54H H 21 15H 53 35H 85 55H H 22 16H 54 36H 86 56H H 23 17H 55 37H 87 57H H 24 18H 56 38H 88 58H H 25 19H 57 39H 89 59H H 26 1AH 58 3AH 90 5AH 122 7AH 27 1BH 59 3BH 91 5BH 123 7BH 28 1CH 60 3CH 92 5CH 124 7CH 29 1DH 61 3DH 93 5DH 125 7DH 30 1EH 62 3EH 94 5EH 126 7EH 31 1FH 63 3FH 95 5FH 127 7FH * Decimal expressions used for MIDI channels, bank select, program change and device ID are 1 greater than the decimal value shown on above table. 19

20 MIDI Implementation Exclusive message examples and checksum calculation Roland exclusive messages (RQ1, DT1) contain a checksum following the data (after F7), which can be used to check whether the message was received correctly. The checksum value is derived from the address and data (or size) of the transmitted exclusive message. Calculating the checksum (`H' is appended to hexadecimal numbers) The checksum is a value that produces a lower 7 bits of zero when the address, size, and checksum itself are summed. If the exclusive message to be transmitted has an address of aah bbh cch and the data is ddh eeh, the actual calculation would be as follows: aa + bb + cc + dd + ee = sum sum / 128 = quotient o o o remainder remainder = checksum <Example 1> When setting Tally Indicators to A=input#1/red, B=input#3/green, C=input8/red :- F0H 41H 10H 00H 00H 4FH 12H 00H 00H 00H 00H 02H 02H 01H 07H 02H??H F7H (1) (2) (3) (4) (5) (6) (7) (8) (9) From "Parameter Address Map", the start address of Tally Indicator is 00H 00H 00H, and values are A=00H 2H, B= 02H 01H, C=07H 02H. Therefore, those should be transmitted sequentially. (1) Exclusive Status (2) ID Number (Roland) (3) Device ID (17) (4) Model ID (MVS-12) (5) Command ID (DT1) (6) Address (7) Data (8) Checksum (9) EOX Next, calculate the checksum. 00H+00H+00H + 00H+02H+ 02H+01H + 07H+02H = = 14 (sum) 14 (sum) / 128 = 0 (quotient)...14 (remainder) Checksum = (remainder) = 114 = 72H Thus, the message to transmit is :- F0H 41H 10H 00H 00H 4FH 12H 00H 00H 00H 00H 02H 02H 01H 07H 02H 72H F7H <Example 2> Locate 10 windows (2) in multi-out layout using stxmvl command. F0H 41H 10H 00H 00H 4FH 12H 02H 4DH 56H 4CH 3AH 32H 3BH??H F7H (1) (2) (3) (4) (5) (6) (7) (8) (9) (1) Exclusive Status (2) ID Number (Roland) (3) Device ID (17) (4) Model ID (MVS-12) (5) Command ID (DT1) (6) Command (stxmvl:) (7) Data (2;) (8) Checksum (9) EOX Next, calculate the checksum 02H+4DH+56H+4CH+3AH +32H+3BH = = 408 (sum) 408 (sum) /128 = 3 (quotient)...24 (remainder) Checksum = (remainder) = 104 = 68H Thus, the message to transmit is :- F0H 41H 10H 00H 00H 4FH 12H 02H 4DH 56H 4CH 3AH 32H 3BH 68H F7H 20

21 MIDI Implementation Default Settings of MIDI In/Out MIDI OUT/THRU This sets the MIDI output parameter. By default, this is set to [Thru]. CTRL CH This sets MIDI Rx channel of MVS-12. By default this is set to [1]. Device ID This is the ID for transmission of System Exclusive Message. By default, this is set to 0x10 (17). LVS-800 ver. This selects Tally information to receive. By default, this is set to [1.0]. * Depending on [LVS-800 ver.] setting and receipt of V-LINK on/off message, the operation of MVS-12 differs as below. MVS_operation_E.eps When booted or received V-LINK OFF message When received V-LINK ON message [LVS-800 ver.] setting [1.0] [1.1-] [1.0] [1.1-] Control Command Yes Yes Yes Yes MIDI-EX TALLY Yes Yes Yes Yes PC, CC(00H), CC(0BH), TALLY Yes No No No PC Matrix 1 Input Select No No Yes Yes 21

22 MIDI Implementation Chart fig.midi-chart.eps Model MVS-12 Date : Jul Version : 1.00 Function Transmitted Recognized Remarks Basic Channel Mode Note Number Velocity ON Velocity OFF After Touch KEY After Touch CH Pitch Bend Default Changed Default Message Altered Mode 3 Control Change 00H,0BH TALLY Information Display (*1) Program Change 00H-0BH TALLY Information Display (*1) Matrix Out Input Switch (*2) Exclusive Common Real-Time Others Remote Control TALLY Information Display V-LINK On/Off Mode 1 : OMNI ON, POLY Mode 3 : OMNI OFF, POLY Mode 2 : OMNI ON, MONO Mode 4 : OMNI OFF, MONO *1 When [LVS-800 ver] is set to [1.0]. *2 When MVS-12 receives V-LINK On message. 22

DIGITAL PIANO Date: Oct. 5, 2000 Model HP 147R MIDI Implementation Version: 1.00

DIGITAL PIANO Date: Oct. 5, 2000 Model HP 147R MIDI Implementation Version: 1.00 DIGITAL PIANO Date: Oct. 5, 2000 Model HP 147R MIDI Implementation Version: 1.00 1. Receive Data Channel Voice Messages Note off 8nH kkh vvh 9nH kkh 00H kk = note number: 00H-7FH (0-127) vv = note off

More information

MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI

MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI EN DE FR ES MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI 1. NOTE ON/OFF 3. MODE MESSAGES Data format: [9nH] -> [kkh] -> [vvh] Data format: [BnH] -> [cch] -> [vvh]

More information

PX-360M/PX-560M MIDI Implementation

PX-360M/PX-560M MIDI Implementation PX360M/PX560M MIDI Implementation CASIO COMPUTER CO., LTD. Contents I Overview 3 1 Product Configuration as a MIDI Device 3 1.1 System Section.......................................... 3 1.2 Performance

More information

DIGITAL PIANO Date: June. 1, 2000 Model HP-557R MIDI Implementation Version: 1.00 KR-277/377/577/977/1077

DIGITAL PIANO Date: June. 1, 2000 Model HP-557R MIDI Implementation Version: 1.00 KR-277/377/577/977/1077 DIGITAL PIANO Date: June. 1, 2000 Model HP-557R MIDI Implementation Version: 1.00 KR-277/377/577/977/1077 1. Receive data * Messages for which [model name] is indicated are applicable only to that specific

More information

MIDI Implementation. Model VE-GS Pro Version 1.00 '99.3. Section 1. Receive data. Channel Voice Messages

MIDI Implementation. Model VE-GS Pro Version 1.00 '99.3. Section 1. Receive data. Channel Voice Messages The VE-GS Pro implements additional functionality and parameters over and above the SC-88, which itself was an expansion of the GS sound source format. These functions and parameters are marked by a [Pro]

More information

MIDI Reference CLP- 525

MIDI Reference CLP- 525 MIDI Reference CLP- 525 Table of Contents MIDI Functions... 2 MIDI Transmit/Receive Channel Selection...2 Local Control ON/OFF...2 Program Change ON/OFF...3 Control Change ON/OFF...3 MIDI Data Format...

More information

CLP-370/340/330 CLP-S308/S306

CLP-370/340/330 CLP-S308/S306 CLP-370/340/330 CLP-S308/S306 MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI MIDI Channel Message : Can be transmitted and recognized. : Cannot be transmitted by

More information

F 0 2 M I D I R e f e r e n c e EN

F 0 2 M I D I R e f e r e n c e EN F02 MIDI Reference EN MIDI Channel Message : Can be transmitted and recognized. : Cannot be transmitted by the panel operations, but can be transmitted by song playback data. : Cannot be transmitted or

More information

DATA LIST Daten-Liste Liste des données Lista de datos

DATA LIST Daten-Liste Liste des données Lista de datos DATA LIST Daten-Liste Liste des données Lista de datos EN DE FR ES MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI MIDI Channel Message : Can be transmitted and recognized.

More information

2008 ROLAND CORPORATION

2008 ROLAND CORPORATION Digital Piano Model: RD-700GX MIDI Implementation Date: Feb. 1, 2008 Version: 1.00 1. Receive data Channel Voice Messages Note off 8nH kkh vvh 9nH kkh 00H kk = note number: 00H - (0-127) vv = note off

More information

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE COMMUNICATION INSTRUCTION MANUAL THT-500-A/R (C5) No. THT5CE2 2018.04 This manual contains instructions for communication functions of the THT-500-A/R. 1. System Configuration 1.1 When Using USB Communication

More information

Sender Receiver Sender

Sender Receiver Sender EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other

More information

2006 ROLAND CORPORATION

2006 ROLAND CORPORATION sampling groovebox Model: MC-808 MIDI Implementation Date: December. 14, 2006 Version: 1.00 1. Receive data (Sound Source Section) Channel Voice Messages Note off 8nH kkh vvh 9nH kkh 00H kk = note number:

More information

PX-3 MIDI Implementation

PX-3 MIDI Implementation PX-3 MIDI Implementation CASIO COMPUTER CO., LTD. Contents Part I MIDI Message Overview 1 Product Configuration as a MIDI Device... 6 1.1 System Section... 6 1.2 Sound Generator Section... 6 1.2.1 Sound

More information

Roland GW-7 MIDI Implementation

Roland GW-7 MIDI Implementation Model: GW-7 Date: Nov.24, 2004 Version: 1.00 1. Receive data Channel Voice Messages Note off 8nH kkh vvh 9nH kkh 00H kk = note number: 00H - (0-127) vv = note off velocity: 00H - (0-127) * For Drum Parts,

More information

CT-X700/CT-X800/CTX-870IN MIDI Implementation

CT-X700/CT-X800/CTX-870IN MIDI Implementation CT-X700/CT-X800/CTX-870IN MIDI Implementation CASIO COMPUTER CO., LTD. Contents I Overview 4 1 Product Configuration as a MIDI Device 4 1.1 System Section.......................................... 4 1.2

More information

C1098 JPEG Module User Manual

C1098 JPEG Module User Manual C1098 JPEG Module User Manual General Description C1098 is VGA camera module performs as a JPEG compressed still camera that can be attached to a wireless or PDA host. Users can send out a snapshot command

More information

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422

More information

JCL-33A (C5) Warning. 1. System Configuration COMMUNICATION INSTRUCTION MANUAL

JCL-33A (C5) Warning. 1. System Configuration COMMUNICATION INSTRUCTION MANUAL COMMUNICATION INSTRUCTION MANUAL JCL-33A (C5) No.JCL3CE3 2018.11 This manual contains instructions for the communication functions, operations and notes when operating the JCL-33A. To prevent accidents

More information

COMMUNICATION INSTRUCTION MANUAL Temperature Controller KT4R

COMMUNICATION INSTRUCTION MANUAL Temperature Controller KT4R COMMUNICATION INSTRUCTION MANUAL Temperature Controller KT4R No. KT4RCE1 2015.06 This manual contains instructions for communication functions of the KT4R. To prevent accidents arising from the misuse

More information

Projector Control Command Reference Manual

Projector Control Command Reference Manual Projector Control Reference Manual NEC Display Solutions, Ltd. 2014-2017 BDT140013 Revision 6.1 Introduction This manual describes the commands used to control an NEC-made projector from a PC or other

More information

ES-8 Bulk Dump Messages Date: Apr. 22, 2015

ES-8 Bulk Dump Messages Date: Apr. 22, 2015 ES-8 Bulk Dump Messages Date Apr. 22, 2015 Versin 1.00 Intrductin This dcument eplains hw the ES-8 bulk dump messages are structured. Nte The bulk dump messages f the ES-8 handle the unit s internal data

More information

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E

INSTRUCTION MANUAL FOR GCS-300 COMMUNICATION [OPTION CODE: C5] GCSC3E INSTRUCTION MANUAL FOR COMMUNICATION [OPTION CODE C5] GCSC3E1 2002.04 To prevent the accidents by mishandling of this controller, please arrange to give this manual into the hands of the operator who actually

More information

Status. 2. Transmitted data. (*)Control Change. (*)Program Change Status 2nd Byte CnH pph. (*)Timing Clock. Status F8H. (*)Start.

Status. 2. Transmitted data. (*)Control Change. (*)Program Change Status 2nd Byte CnH pph. (*)Timing Clock. Status F8H. (*)Start. MIDI Implementation Model: GT-1000 Date: September 05, 2018 Version: 1.20 1. Recognized data If "MENU:MIDI:MIDI SETTING:MIDI IN THRU" and "MENU:MIDI:MIDI SETTING:USB IN THRU" are set to anything other

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

VC-C50i COMMUNICATION CAMERA PROGRAMMER'S MANUAL

VC-C50i COMMUNICATION CAMERA PROGRAMMER'S MANUAL VC-C50i COMMUNICATION CAMERA PROGRAMMER'S MANUAL Contents 1. Getting Started... 6 2. Connection with your Computer... 6 2.1 Connection... 6 2.2 Connector & Pin Assignment... 7 3. Communication Format...

More information

REMOTE SERIAL COMMUNICATION CONTROLLER LAN NODE PCB (RSC) Part No. 46S For use on MicroTrac DSD Local Area Network

REMOTE SERIAL COMMUNICATION CONTROLLER LAN NODE PCB (RSC) Part No. 46S For use on MicroTrac DSD Local Area Network REMOTE DEVICE USER REFERENCE SHEET FOR REMOTE SERIAL COMMUNICATION CONTROLLER LAN NODE PCB (RSC) Part No. 46S02790-0030 For use on MicroTrac DSD Local Area Network Effective 9/25/90 1 CONTENTS INTRODUCTION...3

More information

Model LM-1000/ 1000P/ 1200

Model LM-1000/ 1000P/ 1200 AUTO LENSMETER Model LM-1000/ 1000P/ 1200 RS-232C INTERFACE MANUAL December, 2008 Pages in total: 60 31001*RTZ001E/E NIDEK CO., LTD. : 34-14, Maehama, Hiroishi-cho, Gamagori, Aichi 443-0038, Japan (Manufacturer)

More information

TABLE OF CONTENTS. Communication Functions

TABLE OF CONTENTS. Communication Functions TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................

More information

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual HOME AUTOMATION, INC. Model 93A00-1 Serial Server User s Manual Document Number 93I00-1 Rev. A December, 2009 Introduction The 93A00-1 is a RS232/RS485 to TCP/IP converter integrated with a robust system

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

2001 ROLAND CORPORATION

2001 ROLAND CORPORATION Model: SH-32 Date: Dec. 12, 2001 Version: 1.00 1. Receive Data Channel Voice Messages Note ff 8nH kkh vvh 9nH kkh 00H kk = note number: 00H - 7FH (0-127) vv = note off velocity: 00H - 7FH (0-127) Note

More information

JX-3P MIDI Expansion Kit. User manual

JX-3P MIDI Expansion Kit. User manual J-3P MIDI Expansion Kit User manual Language: English Manual Version: 3.01 Date: January 5, 2018 Website: http://www.riversynths.com Email: info@riversynths.com Please note: * Roland is a registered trademark

More information

VC-C4 COMMUNICATION CAMERA PROGRAMMER'S MANUAL

VC-C4 COMMUNICATION CAMERA PROGRAMMER'S MANUAL VC-C4 COMMUNICATION CAMERA PROGRAMMER'S MANUAL Contents 1. Getting Started... 5 2. Connection with your Computer... 5 2.1 Connection... 5 2.2 Connector & Pin Assignment... 5 3. Communication Format...

More information

C1182 Video Compression Module User Manual. Release Note: 1 st Release : Aug 01, 2012

C1182 Video Compression Module User Manual. Release Note: 1 st Release : Aug 01, 2012 C1182 Video Compression Module User Manual Release Note 1 st Release Aug 01, 2012 General Description This is a series of camera modules which perform video compression and output video stream through

More information

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter APCON100 series Operation Manual RS-232 to Ethernet Converter Page 1 of 24 APCON100 series Operation Manual Index Chapter 1 Specifications 2 Chapter 2 Introduction 3 Chapter 3 Easy Installation 4 Chapter

More information

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring

More information

COMMUNICATION INSTRUCTION MANUAL PC-935, PC-955 (OPTION CODES: C, C5, SVTC)

COMMUNICATION INSTRUCTION MANUAL PC-935, PC-955 (OPTION CODES: C, C5, SVTC) COMMUNICATION INSTRUCTION MANUAL PC-935, PC-955 (OPTION CODES: C, C5, SVTC) --- CONTENTS --- 1. System configuration 1.1 System configuration (1) RS-232C (option C) -------------------------------------------------------------

More information

INVERTER E510. Communication Addendum. ModbusRTU/ASCI. DOCUMENT-TECO-E510-AC001 Ver01:

INVERTER E510. Communication Addendum. ModbusRTU/ASCI. DOCUMENT-TECO-E510-AC001 Ver01: INVERTER E510 Communication Addendum ModbusRTU/ASCI DOCUMENT-TECO-E510-AC001 Ver01:2015.03 Table of Contents 1.0 Modbus Protocol Description... 1-1 1.0.1 Communication Connection and Data Frame... 1-1

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

TOA IC-100 Institutional Intercom. Remote Control and Monitoring Programmer's Guide

TOA IC-100 Institutional Intercom. Remote Control and Monitoring Programmer's Guide TOA IC-100 Institutional Intercom Remote Control and Monitoring Programmer's Guide Overview IC-100 security installations often require integration with touch-screen control systems, graphic annunciator

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

1. System configuration

1. System configuration COMMUNICATION INSTRUCTION MANUAL ACD/R-3A, ACD/R-5A (C, C5) No. ACDRCE2 2008.08 This manual contains instructions for communication functions of the ACD-3A, ACR-3A, ACD-5A and ACR-5A. Serial communication

More information

Controlling the projector using a personal computer

Controlling the projector using a personal computer DLP Projector EX320U/EW330U/EX320U-ST Controlling the projector using a personal computer This projector can be controlled by connecting a personal computer with RS-232C terminal. PC-controllable functions:

More information

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485) Application Notes (003) Serial Interface (RS232/RS422/RS485) Version 2.0 Sollae Systems Co., Ltd. 1. Overview supports three serial interfaces: RS232, RS422, and RS485. You can select the interface you

More information

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1) COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER No.KTC3E2 2006.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. For this product

More information

MIDI Note Numbers Assigned to Pads

MIDI Note Numbers Assigned to Pads ELECTRONIC DRUM KIT DTX402K DTX432K DTX452K MIDI Reference How to Use This Manual This MIDI Reference will prove useful when transferring MIDI data between the drum module that came with your DTX402K,

More information

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page Title page GE Digital Energy D90 Plus Line Distance Protection System Communications guide D90 Plus firmware revision:.9x GE publication code: 60-9070-F (GEK-3469) GE Digital Energy 650 Markland Street

More information

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.

THERMO-CON. Model No. HECR002-A5. Keep available whenever necessary. HEC-OM-S008 Aug.2014 Communication Manual THERMO-CON Model No. HECR002-A5 Keep available whenever necessary. This manual is copyrighted and all rights are reserved by SMC Corporation, and may not, in whole

More information

Last sine waveform is output constantly to allow test of audio output. Board must be reset to exit test mode and return in normal mode.

Last sine waveform is output constantly to allow test of audio output. Board must be reset to exit test mode and return in normal mode. DREAM Special NRPN Controls NRPN sending method: CTRL#99=high byte, CTRL#98=low byte, CTRL#6=vv Example: In order to set General Master Volume (NRPN 3707h) to value 64 (40h), send CTRL#99=56 (37h) (MIDI

More information

BMV Text Protocol. Table of contents

BMV Text Protocol. Table of contents BMV Text Protocol Table of contents Introduction... 2 Physical interface... 2 Serial port configuration... 2 Message format... 3 Data integrity... 3 Units... 3 Other statistics... 4 Since firmware version

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration

More information

ATID UHF RFID READER Protocol. July 2009 ATID900F - V0.0.3

ATID UHF RFID READER Protocol. July 2009 ATID900F - V0.0.3 Specification for RFID Reader Host Interface ATID UHF RFID READER Protocol July 2009 ATID900F - V0.0.3 Copyright c 2009, ATID Inc. All rights reserved 1-28 Document Version Ø 2008.11.26 Ver 0.0.1 The protocol

More information

Controlling the projector using a personal computer

Controlling the projector using a personal computer DLP Projector EX320U/EW330U/EX320U-ST/EX321U-ST/EW331U-ST/EX321U Controlling the projector using a personal computer This projector can be controlled by connecting a personal computer with RS-232C terminal.

More information

DIGI-HD-8X8. 8 input by 8 output Matrix Switcher. This Manual is Optimized for Version 2.0 Matrices

DIGI-HD-8X8. 8 input by 8 output Matrix Switcher. This Manual is Optimized for Version 2.0 Matrices DIGI-HD-8X8 8 input by 8 output Matrix Switcher This Manual is Optimized for Version 2.0 Matrices Table of Contents Overview... 4 Installation... 5 Operation... 8 Technical Specifications... 14 Appendix

More information

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax: Description of options TCP/IP Ethernet module user s manual DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189320029B Legal information

More information

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual Communication Instruction Manual IM3523 IM3533 IM3533-01 IM3536 LCR METER IM3570 IM7580 IMPEDANCE ANALYZER IM3590 CHEMICAL IMPEDANCE ANALYZER November 2014 Revised edition 6 IM3570A983-06 14-11H i Contents

More information

CDP-230R MIDI Implementation

CDP-230R MIDI Implementation CDP-230R MIDI Implementation CASIO COMPUTER CO., LTD. Contents I MIDI Message Overview 5 1 Product Configuration as a MIDI Device 5 1.1 System Section.......................................... 5 1.2 Performance

More information

Sequential Event Recorder

Sequential Event Recorder DESCRIPTION Sequential Event Recorder Product Specifications and Installation Data The Sequential Event Recorder (SER) is an intelligent Genius I/0 block that resides directly on the Genius LAN. The primary

More information

User Guide AV-HS6000 Series Plug-in Software

User Guide AV-HS6000 Series Plug-in Software User Guide AV-HS6000 Series Plug-in Software W0615HM2098 -PS ENGLISH VQT5L80-2 Contents Introduction... 3 Registration and Launch Setting... 3 AUX_IP(V3.XX)... 4 ... 4 ... 4 ...

More information

Universal Asynchronous Receiver Transmitter Communication

Universal Asynchronous Receiver Transmitter Communication Universal Asynchronous Receiver Transmitter Communication 13 October 2011 Synchronous Serial Standard SPI I 2 C Asynchronous Serial Standard UART Asynchronous Resynchronization Asynchronous Data Transmission

More information

I/O Interface DNA300

I/O Interface DNA300 DNA300 OPERATIONS MANUAL 1 Ring Communications, Inc. Crisis Alert System I/O Interface DNA300 2 DNA300 OPERATIONS MANUAL 2006/06/13 DNA300 OPERATIONS MANUAL 3 Contents INTRODUCTION... 5 INSTALLATION...

More information

WIE485 and WIE232. Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers

WIE485 and WIE232. Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers 24. srpna 2016 w w w. p a p o u c h. c o m WIE485 and WIE232 Product Data Sheet Created: 5.10.2010 Last

More information

ShenZhen Top Create Electronic Co.,Ltd. Website: Tel: CJ - CAM User Manual.

ShenZhen Top Create Electronic Co.,Ltd. Website:  Tel: CJ - CAM User Manual. ShenZhen Top Create Electronic Co.,Ltd Website: www.szccge.cn.alibaba.com Tel: +86-755-25937185-85 CJ - CAM User Manual OV528 Protocol OV528 PROTOCOL Serial Interface Single-byte Timing Diagram RS232 single-byte

More information

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer Chapter 11: Input/Output Organisation Lesson 05: Asynchronous RS232C Serial Port data transfer Objective Understand the RS232C asynchronous data transfer and signals Learn the RS232C serial port communication

More information

8 8 HDMI over CAT5e/6/7 Matrix - ID# 15122

8 8 HDMI over CAT5e/6/7 Matrix - ID# 15122 8 8 HDMI over CAT5e/6/7 Matrix - ID# 15122 Operation Manual Introduction Features Applications The HDBaseT Lite 8 by 8 HDMI Matrix over CAT5e/6/7 supports the transmission of video (resolutions up to 1080p

More information

JCS, JCM, JCR, JCD-33A (C5)

JCS, JCM, JCR, JCD-33A (C5) COMMUNICATION INSTRUCTION MANUAL JCS, JCM, JCR, JCD-33A (C5) No.JC3CE11 2013.01 This manual contains instructions for the communication functions, operations and notes when operating the JCS, JCM, JCR

More information

DN-700C / DN-501C MIDI Command Guide

DN-700C / DN-501C MIDI Command Guide DN-700C / DN-501C September 10 th, 2014 Ver.1.00 1 Contents 1. General... 3 2. Specification... 4 2-1. RS-232C Control... 4 2-2. IP Control (Ethernet) * DN-700C only... 6 3. Communication Protocol... 7

More information

1 port RS-232 Device Server

1 port RS-232 Device Server 1 port RS-232 Device Server Ethernet RJ45 1 Port Transmit and receive and Ethernet Link and 100/10M LED drive. 10/100 Mbps, auto MDI/MDIX Gateway IP address Serial Interface 1 Port 15 KV ESD protection

More information

Vorne Industries. 87/708 Master Clock Display User's Manual

Vorne Industries. 87/708 Master Clock Display User's Manual Vorne Industries 87/708 Master Clock Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 www.vorne.com Chapter 1 Setting Up Your Display For Operation...

More information

User Guide. AV-HS6000 Series Plug-in Software ENGLISH

User Guide. AV-HS6000 Series Plug-in Software ENGLISH User Guide AV-HS6000 Series Plug-in Software ENGLISH W0214NS1104 YI VQT5K78 1 The AV-HS6000 series 2ME Live Switcher supports plug-in software that can be registered to include additional

More information

PCL Port RS-232 Interface Card

PCL Port RS-232 Interface Card PCL-858 8-Port RS-232 Interface Card Copyright Notice This documentation and the software included with this product are copyrighted 2001 by Advantech Co., Ltd. All rights are reserved. Advantech Co.,

More information

8-OUTPUT MIDI-CONTROLLED RELAY ARRAY

8-OUTPUT MIDI-CONTROLLED RELAY ARRAY 8-OUTPUT MIDI-CONTROLLED RELAY ARRAY MIDI Solutions R8 Operating Instructions M326 c 2001 MIDI Solutions, Inc. All Rights Reserved Printed in Canada MIDI Solutions, Inc. P.O. Box 3010 Vancouver, BC Canada

More information

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3 TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:

More information

INSTRUCTION MANUAL FOR PC LINK UNIT CLT-20S

INSTRUCTION MANUAL FOR PC LINK UNIT CLT-20S INSTRUCTION MANUAL FOR PC LINK UNIT PREFACE Thank you for your purchase of our PC link unit. This manual contains instructions for the mounting, functions, operations and notes when operating the. For

More information

RS232/LAN Serial Communication Control. Specification for A3112 (MDT701S/LDT701V)

RS232/LAN Serial Communication Control. Specification for A3112 (MDT701S/LDT701V) RS232/LAN Serial Communication Control Specification for A3112 (MDT701S/LDT701V) 1. Application This document defines the communication protocols for serial control of the A3112(MDT701S/LDT701V). A3112:

More information

Communication Protocol Guide Version 1.4.0

Communication Protocol Guide Version 1.4.0 VideoReQuest Series Communication Protocol Guide Version 1.4.0 IR, RS-232, and Ethernet Interface Guide Table of Contents Table of Contents...I Revision History...II Introduction...1 Conventions Used...1

More information

Serial Interfacing. Asynchronous Frame

Serial Interfacing. Asynchronous Frame Serial Interfacing Serial Data Transfer used by keyboards, plotters, modems and other peripherals with low data transfer rates (low bandwidth) 2 Types: Asynchronous CPU and device are not using a common

More information

A-01 Supplementary Manual

A-01 Supplementary Manual A-01 Supplementary Manual Cpyright 2016 ROLAND CORPORATION 01 CONTROLLER Mde Yu can assign the fllwing messages t the ribbn cntrllers (C1, C2) and rtary encders (R1 R4) and use them fr cntrl. Display Eplanatin

More information

ABLELink. Modbus Gateway MB5000 Series User s Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual ABLELink MB5000 Series User s Manual Version 1.1 Updated in March, 2010 TEL: 886-3-5508137 FAX: 886-3-5508131 http://www.atop.com.tw Table of Contents Table of Contents... 2 Introduction... 4 Features...

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

4K LASER FRONT PROJECTOR REMOTE CODES

4K LASER FRONT PROJECTOR REMOTE CODES 4K LASER FRONT PROJECTOR REMOTE CODES Changes Dreamvision provides this manual as is without warranty of any kind, either expressed or implied, including but not limited to the implied warranties or merchantability

More information

ECOV-110 User s Manual

ECOV-110 User s Manual ECOV-110 User s Manual 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ECOV-110 Firmware upgrade ECOV-110 1. ECOV-110 Product Introduction: 1.1.

More information

COMLI. System Description

COMLI. System Description COMLI System Description COMLI System Description Copyright 1998 ABB Satt AB. The contents of this document can be changed by ABB Satt AB without prior notice and do not constitute any binding undertakings

More information

1. System Configuration

1. System Configuration COMMUNICATION INSTRUCTION MANUAL PCB1 (C5W, C5) No. PCB1CE1 2017.07 This manual contains instructions for communication functions of the PCB1. Serial communication and Console communication cannot be used

More information

Communication. Outline of Communication. Merits

Communication. Outline of Communication. Merits Communication Outline of Communication You can connect up to MINAS-A series with your computer or NC via serial communication based on RS and RS, and can execute the following functions. () Change over

More information

Grandstage 88/73 MIDI Guide

Grandstage 88/73 MIDI Guide Grandstage 88/73 MIDI Guide E 1 Table of contents MIDI settings----------------------------------------------------------------------------------------2 About MIDI--------------------------------------------------------------------------------------------2

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

BF-430 User Manual Document Version 1.0 Web Version realcom Firmware Version ,Apr

BF-430 User Manual Document Version 1.0 Web Version realcom Firmware Version ,Apr BF-430 User Manual Document Version 1.0 Web Version realcom 2009-02-07 Firmware Version 1.13.00,Apr 4 2011 Index Ⅰ Hardware Introduction...1 Ⅱ Product Overview...3 Ⅲ WEB Login...4 Ⅳ Web Instruction...10

More information

Controlling the projector using a personal computer

Controlling the projector using a personal computer AUDIO OUT AUDIO IN-1 AUDIO IN-2 AUDIO IN-3L AUDIO IN-3R S-VIDEO VIDEO SERIAL MONITOR OUT COMPUTER / COMPONENT VIDEO IN-1 IN-2 USB-B USB-A DLP TM MODEL Projector XD550U/XD560U/WD570U/XD360U-EST/WD380U-EST/XD365U-EST/WD385U-EST

More information

10. RS-232C communication

10. RS-232C communication 10. RS-232C communication PB9200(P5XMLA) Connecting the cable (1) Turn off the projector and the computer power supplies. (2) Connect the CONTROL port of the projector with a RS-232C port of the computer

More information

Controlling the projector using a personal computer

Controlling the projector using a personal computer MODEL UD740U Controlling the projector using a personal computer This projector can be controlled by connecting a personal computer with RS-232C terminal. PC-controllable functions: Turning the power ON

More information

Digital Projector X30N/X35N

Digital Projector X30N/X35N Digital Projector X30N/X35N Operator's Guide TECHNICAL Warranty 3M warrants that when the 3M Product is used according to 3M s Intended Use Statement (www.3m.com/meetings), it will perform satisfactorily

More information

====================================================================== Control Commands for LV series Rev1.0.4

====================================================================== Control Commands for LV series Rev1.0.4 ====================================================================== Control Commands for LV series Rev1.0.4 Copyright (C) NEC Display Solutions, Ltd. 2006-2010 ----- Updated on January 25, 2010 -----

More information

Back to. Communication Products Group. Technical Notes. Local/Remote Control and Functional Description, 1:1 Redundant Switching Unit, One Rack Unit

Back to. Communication Products Group. Technical Notes. Local/Remote Control and Functional Description, 1:1 Redundant Switching Unit, One Rack Unit Back to Communication Products Group Technical Notes 25T008 Local/Remote Control and Functional Description, 1:1 Redundant Switching Unit, One Rack Unit MITEQ TECHNICAL NOTE 25T008 MAY 1997 REV D LOCAL/REMOTE

More information

Preliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM

Preliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM Preliminary Single-Chip USB to UART Bridge SINGLE-CHIP USB to UART DATA TRANSFER - Integrated USB Transceiver; No External Resistors Required - Integrated Clock; No External Crystal Required - Integrated

More information

1. Communication Data Frame

1. Communication Data Frame Page : 1 1. Communication Data Frame EDX series inverter can be communication controlled by the PC or other controller with the communication protocol, Modbus ASCII Mode & Mode RTU, RS485 or RS232. Frame

More information

Dot Matrix Printer. SP300 Series. Programmer s Manual

Dot Matrix Printer. SP300 Series. Programmer s Manual Dot Matrix Printer SP300 Series Programmer s Manual TABLE OF CONTENTS 1. CONTROL PANEL... 1 1-1. Basic Operation... 1 1-2. Switch Operation (Combined Switch Operation)... 2 2. SERIAL INTERFACE... 7 2-1.

More information

Version 2.0 Manual Supplement

Version 2.0 Manual Supplement E AW4416 This manual supplement explains the functions and specifications that have been added or changed in version 2.0 of the AW4416 s system software. Operation explains how to use the new functionality,

More information