CS121 AUX Adapter for AS 400 UPS interface CS 121 AUX RJ11 6-pol Layout:

Size: px
Start display at page:

Download "CS121 AUX Adapter for AS 400 UPS interface CS 121 AUX RJ11 6-pol Layout:"

Transcription

1 Version: CS121 AUX Adapter for AS 400 UPS interface CS 121 AUX RJ11 6-pol Layout: Pin1: -> +5V Pin2: -> Input 1 Pin3: -> Input 2 Pin4: -> Input 3 Pin5: -> Input 4 Pin6: -> GND Adapter for AS 400 : Connect this adapter directly to your AS 400 UPS interface. Connect the Adapter with a RJ11 cable (max. 10 meters) to your CS121 AUX port. AS 400 RS232 / DB9 male CS 121 AUX RJ 11 6pol Pin 5 / Ground Pin 9 / AUX 1 Pin 6 / AUX 2 Pin 7 / AUX 3 Pin 2 / AUX 4 Phototransistor Ground AUX1 AUX 2 AUX 3 AUX 4 AS 400 UPS interface DB 9: Pin 9 Powerfail Pin 6 Bypass Pin 7 Battery Low Pin 2 Summary Alarm (only iseries, not AS400) Copyright of the European Union is effective (Copyright EU) (c) 2018 GENEREX GmbH, Hamburg, Germany, All rights reserved

2 On the newer iseries (as of 2014) the connection between the CS121_AUX_Adapter and the AS400 system will be establish via USB port. For this, IBM provide a UPS RS232 converter, which will be directly connected to the CS121_AUX_Adapter: To get a permanent joint between the CS121_AUX_Adapter and the IBM UPS RS232 Converter, please use the provided union nut: 2

3 On the older 9406 iseries model 520, the UPS connector is P1-T2: Serial port to UPS conversion cable: The new cable is a short converter cable. It physically attaches to one of the serial ports at the back of iseries models 520/550/570. The 1827 converter cable is a 140mm (5.5 in.) serial port to UPS cable for iseries models 520, 550 and 570. These models have no longer the J14 UPS connector. Instead, UPS communications to the iseries is supported through a designated serial port via the 1827 converter cable. The serial port supports two models: RS232 serial port mode and UPS mode. Only one mode is supported at a time. The service processor will detect the presence of an UPS attached through serial port via the 1827 cable when the server is started and set the control hardware to condition the signals for the UPS. The mode cannot be changed unless the system is started again. The following figure shows the converter cable wiring: 3

4 Please see the following screenshots how to setup your CS121 AUX interface for usage with this AS 400/AUX adapter: Generally the AS400AUX plug has to be connected to the J14 UPS interface of the AS 400. The configuration of the UPS service at the AS 400, please refer to the AS 400 manual. The CS121/CS141 has to be configured as follows: 1. Go to CS121 configuration page COM2 & AUX and set the AUX Port as OUTPUT: 2. SETUP in the EVENT configuration the Event POWERFAIL (AUX1), BATTERY LOW (AUX3), BYPASS Alarm of (AUX 2) to High : (Example POWERFAIL below, other EVENTS accordingly) 4

5 Example for AUX 1 3. Generally the following settings in the EVENTS of the CS121/CS141 have to be made: EVENT name AUX Logic Powerfail = AUX 1 = High Powerfail restored = AUX 1 = Low Bypass on = AUX 2 = High Bypass off = AUX 2 = Low Battery low = AUX 3 = High General Alarm = AUX 4 = High 4. Now save your settings and reboot the CS121. As soon as the adapter shows a green flashing LED, connect the AS 400 adapter to the UPS interface on your AS 400 Finish NOTE: You can safely test your configuration via the AUX and TEMPMAN webpage in the CS121 STATUS group. If you click on the OUTPUT ON/OFF buttons you can set the alarms manually to test your installation. 5

Version: LED2-Matrix Display. LED2 Matrix Display. User Manual

Version: LED2-Matrix Display. LED2 Matrix Display. User Manual Version: 2016-08-18 LED2-Matrix Display LED2 Matrix Display User Manual www.generex.de Revision History Date -001-011 -012-013 -014-015 -016 First Release. New Release. Updated LED_2 screenshots Updated

More information

LED-Matrix Display. LED2 Matrix Display. User Manual. Version 2.0

LED-Matrix Display. LED2 Matrix Display. User Manual. Version 2.0 LED-Matrix Display LED2 Matrix Display User Manual Version 2.0 www.generex.de Revision History Date -001 First Release. 09/2006 Legal Information This documentation as well as the software and hardware

More information

SITEMONITOR II. User Manual English. Version:

SITEMONITOR II. User Manual English. Version: Version: 2008-04-02 SITEMONITOR II User Manual English Limited Warranty: This software and the enclosed materials are provided without warranty of any kind. The entire risk as to software quality, performance

More information

Bluetooth RS-232 Dongle. User s Manual BTS-100

Bluetooth RS-232 Dongle. User s Manual BTS-100 Bluetooth RS-232 Dongle User s Manual BTS-100 Table of Contents 1. INTRODUCTION... 2 2. PHYSICAL DIAGRAM... 3 3. BLUETOOTH PAIRING AND CONNECTING... 4 4. RS-232 INSTALLATION... 10 5. HYPERTERMINAL SETTING

More information

MMI6070 Quick Start Guide

MMI6070 Quick Start Guide MMI6070 Quick Start Guide Introduction If at any time more information is required on HMI safety and protection ratings, HMI Power, and HMI communication, please refer to the MMI6070 Installation Guide

More information

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer) Version: 2016-08-18 Multi-IQ Firmware: (Serial Number / Seriennummer) RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable User manual MANUAL ENGLISH... 2 GENERAL PROPERTIES:... 2

More information

TORRIX M12. Technical Documentation. TORRIX Configuration Tool. Edition: Version: 1 Article no.:

TORRIX M12. Technical Documentation. TORRIX Configuration Tool. Edition: Version: 1 Article no.: Technical Documentation TORRIX M12 Edition: 2017-06 Version: 1 Article no.: 350258 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Tel.: +49 /40 / 39 82 07-0 Fax: +49 / 40 / 390 63 39 Table

More information

Hookingupacomputertothe3-wireSimplicity bus.

Hookingupacomputertothe3-wireSimplicity bus. Simplicity Hookingupacomputertothe3-wireSimplicity bus. Purpose OneofthemajoradvantagesoftheSimplicity control is its ability to be connected to a computer. The computer can be used to modify the control

More information

Older Compaq UPS Family - Identifying Serial Communication Cables

Older Compaq UPS Family - Identifying Serial Communication Cables Older Compaq UPS Family - Identifying Serial Communication Cables In this document: Overview Cables Supplied 6 Ft. Communication Cable 12 Ft. Communication Cable Older Compaq UPS Family Communication Port

More information

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.: Technical Documentation VISY-Output 8 8-Channel relay output module Version: 3 Edition: 2016-09 Art. no.: 350072 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07 0 Fax:

More information

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information USB/RS232 to CcTalk COMMUNICATION BOARD 18/04/2016 Manual code: 81043530 ATTENTION: Read this technical manual carefully before installing

More information

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication. 3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series

More information

Cube II/Cube Pro with Go2Nova 8408 Hand Controller Firmware Upgrade

Cube II/Cube Pro with Go2Nova 8408 Hand Controller Firmware Upgrade Cube II/Cube Pro with Go2Nova 8408 Hand Controller Firmware Upgrade The firmware of a Cube II/Cube Pro mount and Go2Nova 8408 hand controller can be upgraded by a customer. Please check ioptron s website,

More information

Starter Guide Version Sphinx Access Control System

Starter Guide Version Sphinx Access Control System TC3XYMT/TC3XYNT Starter Guide Version 1.04.1 Sphinx Access Control System Page 1 1. Controller and Reader wiring...3 2. Connect the controller to PC...4 2.1. Setup the ID of Controller...4 2.2. Connect

More information

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual Model:UT-8814 USB/RS-232 Commercial interface converter Instruction Manual Contents 1. Overview....3 2. Main Features...3 3. Hardware installation and application....3 4. Performance parameters... 4 5.

More information

USB to RS-485/RS-422 Interface Converter. User Manual

USB to RS-485/RS-422 Interface Converter. User Manual USB to RS-485/RS-422 Interface Converter User Manual CONTENTS I. Summary 3 II. Functions..3 III. Hardware installment and application... 3 IV. Performance parameters........4 V. Connector and signal.......4

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS This page contains instructions that will guide you through the process of updating the DiabloSport Predator to the latest software revision available.

More information

Hardware Manual RM CANview

Hardware Manual RM CANview Hardware Manual RM CANview 1998-2005 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cv_hw_e.doc Table of Contents 1 Legal Regulations...3 2 About the CANview...4 3 Important

More information

Code Dynamics, Inc. Port Splitter

Code Dynamics, Inc. Port Splitter Code Dynamics, Inc. Port Splitter Thank you for purchasing the Port Splitter. With this product, you can utilize a single Andover port for both the modem and PC connections. This device connects to the

More information

USB RS485/RS422 Converter INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8

USB RS485/RS422 Converter  INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8 NOVUS AUTOMATION 1/8 USB DRIVER INSTALLATION USB-i485 The following installation steps may be slightly different depending on your PC configuration and Windows version. Follow the Wizard instructions and

More information

ZEQ25GT with Go2Nova 8408 Hand Controller Firmware Upgrade

ZEQ25GT with Go2Nova 8408 Hand Controller Firmware Upgrade ZEQ25GT with Go2Nova 8408 Hand Controller Firmware Upgrade The firmware of a ZEQ25GT, including Go2Nova 8408 hand controller, R.A. and DEC motor drive boards, can be upgraded by a customer. Please check

More information

Dataliner DL40 Plus Message Displays

Dataliner DL40 Plus Message Displays Release Note Dataliner DL40 Plus Message Displays The Dataliner DL40 Plus Message Displays, the next generation of Allen-Bradley message displays, directly replace the Dataliner DL40, DL20 and DL10 Series

More information

RC1170-RC232 USER MANUAL

RC1170-RC232 USER MANUAL RC1170-RC232 USER MANUAL Overview: Introducing RC11XX-RC232 RF Transceiver boards for the data transmission using RF. Where RC11xx transceiver modules are compact surface-mounted high performance modules

More information

Commercial-grade Interface Converter User Manual

Commercial-grade Interface Converter User Manual Suzhou Huarui Thermal Control Co.,Ltd Commercial-grade Interface Converter User Manual Read this manual carefully before installation and use! The document is the exclusive property of SUZHOU HUARUI Thermal

More information

WiFi to RS-232 adapter user manual

WiFi to RS-232 adapter user manual WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126

More information

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX. STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Package Includes/System Requirements PACKAGE INCLUDES

More information

LCD KVM Module. Quick Installation Guide DS DS DS DS DS-72217

LCD KVM Module. Quick Installation Guide DS DS DS DS DS-72217 LCD KVM Module Quick Installation Guide DS-72212 DS-72213 DS-72214 DS-72216 DS-72217 Introduction This is a KVM module, which must work with LCD KVM console (17 DS-72210/19 DS-72211) The modular design

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide

FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide Accuthermo Technology Corp. Safety Note Please read this entire document before you begin connecting cables and assembling your system Failure

More information

CRIBS Installation and User Guide

CRIBS Installation and User Guide CRIBS Installation and User Guide CRIBS Installation and User Guide Multiple Access Communications Ltd Delta House Southampton Science Park Southampton Hants, SO16 7NS UK MAC-UMAN-23-101-02 Page 2 of 12

More information

Hardware technical specifications Front Face of the 512 / 1024 channels interfaces LED 7-segments display operation:...

Hardware technical specifications Front Face of the 512 / 1024 channels interfaces LED 7-segments display operation:... SUMMARY Hardware technical specifications... 4 Front Face of the 512 / 1024 channels interfaces... 5 LED 7-segments display operation:... 5 LED 7-segments Sleep option:... 6 selection Mode button... 6

More information

USB to RS-422/485 Serial Adapter

USB to RS-422/485 Serial Adapter USB to RS-422/485 Serial Adapter User Manual Ver. 4.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

Power Monitor / Power Monitor 51A. Quick guide to set up a connection with the Power Monitor devices through the Weidmüller Serial/Ethernet Converter

Power Monitor / Power Monitor 51A. Quick guide to set up a connection with the Power Monitor devices through the Weidmüller Serial/Ethernet Converter Power Monitor / Power Monitor 51A Quick guide to set up a connection with the Power Monitor devices through the Weidmüller Serial/Ethernet Converter 1.1 Revision history Version Date Change 0.0 11/2013

More information

SmartEQ Pro+ with Go2Nova 8408 Hand Controller Firmware Upgrade

SmartEQ Pro+ with Go2Nova 8408 Hand Controller Firmware Upgrade SmartEQ Pro+ with Go2Nova 8408 Hand Controller Firmware Upgrade The firmware of a SmartEQ Pro+ main board and Go2Nova 8408 hand controller can be upgraded by a customer. Please check ioptron s website,

More information

Installation Guide of Hi-Speed USB Industrial I/O Adapter

Installation Guide of Hi-Speed USB Industrial I/O Adapter Introduction Installation Guide of Hi-Speed USB Industrial I/O Adapter The USB-COMi Industrial I/O Adapter is designed to make industrial communication port expansion quick and simple. Connecting to a

More information

Product Manual. Mini USB to Terminal RS422 RS485 FTDI Plug-in Adapter. Coolgear, Inc. Version 1.1 April 2018 Model Number: USBG-422MiNi

Product Manual. Mini USB to Terminal RS422 RS485 FTDI Plug-in Adapter. Coolgear, Inc. Version 1.1 April 2018 Model Number: USBG-422MiNi Mini USB to Terminal RS422 RS485 FTDI Plug-in Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USBG-422MiNi 2 USBG-422MiNi Product Manual Revision History Revision Date Author

More information

Furman F1000, F1500 Panamax M4320, MB1000, MB1500

Furman F1000, F1500 Panamax M4320, MB1000, MB1500 Manufacturer: Model Number(s): Core Module Version: Document Revision Date: 2/1/2013 Furman, Panamax OVERVIEW AND SUPPORTED FEATURES Furman F1000, F1500 Panamax M4320, MB1000, MB1500 g! 5.6 or newer Integration

More information

Supports extended runtime with optional external battery packs BP72V15-2U or BP72V28RT-3U

Supports extended runtime with optional external battery packs BP72V15-2U or BP72V28RT-3U Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Supports extended runtime with optional external battery packs BP72V15-2U or BP72V28RT-3U 72VDC 3-6 years, depending

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information

WLAN-100 and ETH-100 add-on module

WLAN-100 and ETH-100 add-on module WLAN-100 and ETH-100 add-on module Technical Manual Version 1.1 09 Infranet Technologies Introduction The WLAN-100 / ETH-100 add-on module for modules (RTCU) allows connection to the GPRS Gateway Professional

More information

Instructions manual / DPC Touch Firmware Upgrade 1. DPC Touch Firmware Upgrade SERVICE MANUAL

Instructions manual / DPC Touch Firmware Upgrade 1. DPC Touch Firmware Upgrade SERVICE MANUAL Instructions manual / DPC Touch Firmware Upgrade 1 DPC Touch Firmware Upgrade SERVICE MANUAL Instructions manual / DPC Touch Firmware Upgrade 2 IMPORTANT The tool delivered with this manual may have been

More information

Ethernet Interface Module

Ethernet Interface Module Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)

More information

SP-7 AHRS. Firmware upgrade instructions. Installation and calibration

SP-7 AHRS. Firmware upgrade instructions. Installation and calibration SP-7 AHRS Firmware upgrade instructions Installation and calibration General This document describes the firmware upgrade procedure and new functionality of the SP-7 Firmware release. The firmware upgrade

More information

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS Serial Communications Accessories SITRANS RD200/300 Operating Instructions 05/2013 SITRANS Siemens Auto SIT SITRANS RD300RANS RD300 Safety Guidelines: Warning notices must be observed to ensure personal

More information

Procedure to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU)

Procedure to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU) to Upgrade from SYSCON+ to SYSCON2 and Implement Release 5.0 in a Working Maxum Network Access Unit (NAU) Difficulty Level: High Estimated time to execute: 2 Hours Revision History Issue Date Reason 001

More information

Data Cable for GSP-2900 Fixed Satellite Phone. Installation Instructions. Revised July 2004

Data Cable for GSP-2900 Fixed Satellite Phone. Installation Instructions. Revised July 2004 Data Cable for GSP-2900 Fixed Satellite Phone Installation Instructions Revised July 2004 1 This document provides step-by-step instructions enabling the user to install the GSP- 2900 Data Cable Kit. 1.

More information

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1 STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1 SUMMARY Hardware technical specifications... 3 Front Face of the 512 / 1024 channels interfaces... 4 Side Faces of the 512 / 1024 channels interfaces...

More information

USB-C to RJ45 FTDI Console Cable USB-A to RJ45 FTDI Console Cable

USB-C to RJ45 FTDI Console Cable USB-A to RJ45 FTDI Console Cable USB-C to RJ45 FTDI Console Cable USB-A to RJ45 FTDI Console Cable Quick Start Guide Model 201065 Model 202065 OS Support: Windows 7/8/10 and macos 10.9 and up Download the latest FTDI drivers at cablematters.com/downloads

More information

Chapter. In This Chapter...

Chapter. In This Chapter... SureStep TM Communications Chapter 9 In This Chapter... Connecting to a Host Using RS-485...................9 2 Four-Wire Configuration...............................9 2 Two-Wire Configuration...............................9

More information

On-line, double-conversion power conditioning maintains output within 2% of 100/110/120 volts at all times

On-line, double-conversion power conditioning maintains output within 2% of 100/110/120 volts at all times Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge Runtime is expandable with BP48V24-2U (limit 1) or BP48V60RT3U (multi-pack compatible)

More information

CEM120 Firmware Upgrade

CEM120 Firmware Upgrade CEM120 Firmware Upgrade The firmware of both 8407 hand controller (HC) and mount can be upgraded. The upgrading is only supported by Windows. Please check ioptron s website, www.ioptron.com, under Support,

More information

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization Hall Research Technologies, Inc. Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization UMA1127 Rev B Copyright 2007. Hall Research Technologies, Inc. All rights 1163 Warner

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

ieq45 with 8407 Hand Controller Firmware Upgrade

ieq45 with 8407 Hand Controller Firmware Upgrade ieq45 with 8407 Hand Controller Firmware Upgrade The firmware of an 8407 hand controller, as well as the main control board, R.A. and DEC motor control boards can be upgraded by the customer. Please check

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

Installation Instructions for: Channel Thermocouple Amplifier

Installation Instructions for: Channel Thermocouple Amplifier Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier The Advanced Engine Management (AEM) 4 channel thermocouple amplifier revolutionizes temperature measurements by providing laboratory

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

LBI Mobile Communications S825 FLASH PROGRAMMING. Programming Instructions

LBI Mobile Communications S825 FLASH PROGRAMMING. Programming Instructions LBI-38991 Mobile Communications S825 FLASH PROGRAMMING Programming Instructions TABLE OF CONTENTS INTRODUCTION...3 INSTALLATION...3 REQUIREMENTS...3 MAKING BACKUPS...3 SYSTEM HOOK-UP...4 S825 Control Unit...4

More information

Technical Documentation

Technical Documentation Technical Documentation for metratec QuasarMR1 HF Mid-Range-Reader Date: April 2015 Version: 2.2 Technical Documentation metratec QuasarMR1 Page 1 of 13 Table of Contents 1 General Information / Security

More information

DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY We, the undersigned Company: Address: TE-GROUP nv Kapelsestraat 61, 2950 Kapellen - BELGIUM declare, that the following equipment: Product Name: Blue TWIN Product Type: Bluetooth

More information

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by

More information

ROHS AND WEEE COMPLIANCE

ROHS AND WEEE COMPLIANCE 210Z ROHS AND WEEE COMPLIANCE All lead-free products offered by the company comply with the requirements of the European law on the Restriction of Hazardous Substances (RoHS) directive, which means our

More information

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999 Hardware Manual 232 232232 PCMCIA 1 Port RS232 1.1 EDITION APRIL 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided

More information

Quick Guide. Extra Communication Card

Quick Guide. Extra Communication Card Quick Guide Extra Communication Card Uninterruptible Power Supply System Version: 1.0 Table of Contents 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4.

More information

CodeLoader. Users Guide. P/N: Rev: OCT04

CodeLoader. Users Guide. P/N: Rev: OCT04 CodeLoader Users Guide P/N: 3100788 Rev: 1.0 04OCT04 DEVELOPED BY COPYRIGHT NOTICE TRADEMARKS CREDITS Edwards Company 6411 Parkland Drive Sarasota FL 34243 (941) 739-4300 Copyright 2004 Edwards Company

More information

BB-303 Manual Baseboard for TMCM-303

BB-303 Manual Baseboard for TMCM-303 BB-303 Manual Baseboard for TMCM-303 Trinamic Motion Control GmbH & Co. KG Sternstraße 67 D 20357 Hamburg, Germany http://www.trinamic.com BB-303 Manual (V1.04 / Jul 9th, 2007) 2 Contents 1 Features...

More information

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor. 289H M LSS Installation & Operations Manual Overview Section 1 INTRODUCTION This manual provides procedures for installing and operating the 289H M Loop Surveillance System (LSS) monitor. It addresses

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

UTS485 & ULOG485 USB Converter Owner's Manaul

UTS485 & ULOG485 USB Converter Owner's Manaul UTS485 & ULOG485 USB Converter Owner's Manaul UTS485-002 CONTENTS Chapter 1. Introduction 1-1 Introduction...1 Chapter 2. System Setup 2-1 Introduction...2 2-2 RS422/RS485 interface setting...2 2-3 Installation

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

Peter Norberg Consulting, Inc. Professional Solutions to Professional Problems P.O. Box Ferguson, MO (314)

Peter Norberg Consulting, Inc. Professional Solutions to Professional Problems P.O. Box Ferguson, MO (314) Professional Solutions to Professional Problems P.O. Box 10987 Ferguson, MO 63135-0987 (314) 521-8808 Information and Instruction Manual for the RS232 to TTL-Serial Conversion Board By Copyright 2005-2007

More information

Testing RS232/RS485 Data Radio Modem with Serial Port Tool V1.10

Testing RS232/RS485 Data Radio Modem with Serial Port Tool V1.10 Testing RS232/RS485 Data Radio Modem with Serial Port Tool V1.10 This document demonstrates how to test the communication of RS232/RS485 interface data radio modem DRF4432D20I-043L1/2, DRF1278DL1/2 and

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater For additional information contact matedev@outbackpower.com Page 1 of 14 Revision History Revision 2.0:

More information

How to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect

How to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect How to connect PlusConfig How to connect with the Luxom system There are 3 different ways of connecting your computer to the Luxom system: - LOCAL - IP - MODEM LOCAL This means that we use a Luxom serial

More information

Integration Note OVERVIEW AND SUPPORTED FEATURES INSTALLATION OVERVIEW. Model Number(s): V883, V85

Integration Note OVERVIEW AND SUPPORTED FEATURES INSTALLATION OVERVIEW. Model Number(s): V883, V85 Manufacturer: ELAN Home Systems Model Number(s): V883, V85 Core Module Version: 4.0.1288 and newer (V883) 4.0 1587 and newer (V85) Document Revision Date: 1/15/2013 Integration Note OVERVIEW AND SUPPORTED

More information

UTS400 series USB Converter

UTS400 series USB Converter UTS400 series USB Converter Owner's Manual UTS400-004 CONTENTS ======== Chapter 1. Introduction...1 1-1 Introduction...1 1-2 interface type & order information...1 Chapter 2. System Setup...2 2-1 Introduction...2

More information

Apantac Tahoma Multiviewers - TSL interface

Apantac Tahoma Multiviewers - TSL interface Apantac Tahoma Multiviewers - TSL interface All Apantac Tahoma Multiviewers provide TSL protocol support for dynamic Labels and Tally Management as standard. With the current Tahoma FW version, the Version

More information

ALDL Bluetooth Adapter with USB (MK2)

ALDL Bluetooth Adapter with USB (MK2) 1320 Electronics LLC for: ALDL Bluetooth Adapter with USB (MK2) Contents Warnings 3 Specifications 4 Quick Start Instructions 5 Installing the 'ALDL Bluetooth adapter' 6 Operating the ALDL Bluetooth Adapter

More information

LPC1788 Mio Board. The functional details of the board are as follows-

LPC1788 Mio Board. The functional details of the board are as follows- INTRODUCTION : The LPC1788 Mio is based on Cortex M3 Core, running at up to 120MHz. The Mio lets you quickly start with your development on LPC1788 based designs. The functional details of the board are

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS Multi-port Coax + 2-port 10/100/1000T + 2-port 100/1000X SFP Long Reach PoE over Coaxial Managed Switch LRP-822CS / LRP-1622CS Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements...

More information

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE 7I74 MANUAL 8 CHANNEL RS-422 INTERFACE V1.2 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................

More information

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100 Manufacturer: DSC Integration Note Model Number(s): DSC POWER SERIES / IT-100 Core Module Version: 6.4.209 Comments: Document Revision Date: 9/11/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series

More information

Quick Start Guide. Data Logger TrueLog100

Quick Start Guide. Data Logger TrueLog100 Quick Start Guide Data Logger TrueLog100 Antenna Port 3 Port 4 1 1 1 1 Port 1 1 Port 2 RSSI PC Measure SIM + Battery + Solar Power Supply Figure 1: Top view of the data logger TrueLog100. All ports and

More information

USB-COM Plus ISO (USB-COMi SI-M)

USB-COM Plus ISO (USB-COMi SI-M) VS Vision Systems GmbH / Part Number 603 Features 1 x RS232/422/485 port USB 2.0 Full Speed interface 2.5kV isolation per serial port USB and serial ports ESD protected Robust metal case Jumperless, DIP

More information

Description UPS Management Software

Description UPS Management Software UPSMAN UPSMON/UPSVIEW UPSMON CUSTOM Version: 2016-08-18 UPS MANAGEMENT SOFTWARE UPSMAN/UPSMON/UPSVIEW, and UNMS II Comprehensive UPS Administration and Alerting UNMS II Firewall UPSMAN Server + 2 Sender

More information

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.

More information

IMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information.

IMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information. Manufacturer: GE NetworX Integration Note Model Number(s): NX-4,6,8 Core Module Version: Document Revision Date: 01/09/2016 OVERVIEW AND SUPPORTED FEATURES The NetworX NX-4,6,8 security panels integrate

More information

SitePORTAL Lite TA-SPL32-R48

SitePORTAL Lite TA-SPL32-R48 SitePORTAL Lite TA-SPL32-R48 Quick Connect Guide The TA-SPL32-R48 is a 19 inch, 2 RU rack mountable siteportal Lite (spl). It comes with 8 analog inputs, 8 temperature inputs (sensors sold separately),

More information