Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Size: px
Start display at page:

Download "Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT"

Transcription

1 Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller, then click the magnifying glass icon. Once found, the controller can be identified by its MAC address (e.g. 00:13:48:02:F6:94 which is also printed on the controller). For reliability, you MUST subsequently assign a Static IP Address using the i-net Configurator tool Iss 5

2 2 Contents Contents Introduction 3 Cable Specification 3 Step 1: Fit the Controller to the wall 5 Step 2: Install the Readers 5 Step 3: Connect the RS485 6 Step 4: Connect the Inputs 6 Step 5 Connect the Outputs 6 Step 6: Select the Switch Settings 7 i-net Wiring Diagram 8 Step 7: Connect the LAN 10 Step 8: Power the i-net ACU 10 Step 9: Check LED Indication 11 FAQs 12 Wiring for Sigma Lite Readers 13 i-net Configuration Table 14

3 Introduction / Cable Specification 3 Introduction The i-net Intelligent Access Control Unit from Controlsoft provides a single board solution for one or two doors, which is expandable compatible with Controlsoft s Identity Access software. In addition, other i-net Access Control Units (ACU), CS- AC-3151 Reader Expansion Boards, CS-AC-1100 RS485 Readers and CS-AC-4311 I/O Expansion Boards can be added on the i-net s RS485 ports to expand its capabilities. through the use of additional i-net controllers up to 32 doors. The i-net is compatible with Controlsoft s Identity Access software for further expansion. The i-net controller is available in 4 versions: IA-PCB: i-net controller, PCB only IA-ACB: i-net controller in metal box IA-ACU: i-net controller in metal box with 12V 3A power supply IA-KIT: i-net controller in metal box with 12V 3A power supply with IA-R10P reader. For further information, please refer to the Controlsoft Product Reference Guide available to download from the products page of our website Cable Specification For RS485 connections between ACUs we recommend using Belden 8723 or equivalent. This is a 2 twisted pair cable, with each pair screened as well as an overall screen. Do not use twisted pair CAT5 or CAT6 cables for RS485 connections. Note: the RS485 + and connections must be run on either side of the same twisted pair (e.g. Green and White), with a separate core (e.g. Black) used for the reference. The total distance of an RS485 bus must not exceed 1000m. From the i-net ACU to Wiegand readers we recommend using Belden 9538 (or equivalent). This is an untwisted 8 core cable with an overall screen. Do not use twisted pair CAT5 or CAT6 cables to connect readers to the i-net ACU. The maximum length of the Wiegand reader cable is 80m but if this exceeds 25m we recommend using a local power supply for the reader. Between the i-net ACU and Locks/Exit Buttons we recommend a 22 AWG or thicker gauge alarm cable. We recommend cables with spare cores in case a core breaks. Do not use CAT5 or CAT6 cables to connect locks or exit buttons.

4 4 i-net Configuration Types Example Configurations Standalone i-net Controllers Each i-net Controller has its own IP connection/address, and controls 2 doors (or 1 door with in/out readers). Communication to the PC is over the TCP/IP network. NOTE: The i-net will continue to operate in stand alone mode if the PC is shut down or disconnected. Any events that subsequently occur are stored in the i-net and are automatically sent to the Identity Access software when the PC is back on-line. i-net to i-net The Master i-net Controller is connected to the PC via TCP/IP. Additional Slave i-net Controllers are daisy-chained on the RS485 Port B data line, up to a maximum of 15. These Slave i-nets have fully distributed intelligence, so they continue to operate even if the RS485 data line is broken. When the RS485 data line is restored, the Slave i-nets transfer events to the Master i-net which forwards them to the Identity Access Server software. The RS485 bus must be wired in a daisy-chain topology as shown above and not a STAR topology. NEVER wire additional i-net Controllers on a spur to create a third end. For maximum flexibility, the system can be wired as a combination of the above techniques, allowing system expansion for more than 32 doors

5 Fitting the ACU / Installing the Readers 5 Step 1: Fit the Controller to the Wall Using the base as a template, mark the wall and drill the required mounting and cable entry holes. Plug the mounting holes and fit the housing to the wall. If the controller housing contains a power supply, wire mains to the power supply using an unswitched fused spur. Step 2: Install the Readers The i-net ACU supports the standard Wiegand protocol. See Page 3 for cable requirements. The maximum length of the Wiegand reader cable is 80m but if this exceeds 25m we recommend using a local power supply for the reader. Always check the manufacturer s specifications in the reader manual, as recommendations will vary from manufacturer to manufacturer. Biometric readers When wiring a Morpho fingerprint reader to an i-net reader port, please note the following: Always power the Morpho reader from a power supply, do not power from the i-net reader port. The Morpho reader can be powered via Power over Ethernet (PoE). If using PoE, do not connect the Morpho reader to PoE AND 12Vdc at the same time. For more information, please refer to Appendix A

6 6 Connecting the RS485 / Inputs & Outputs Step 3: Connect the RS485 Bus The RS485 bus must be wired with a twisted pair screened cable. Please refer to the cable specifications on Page 3 The RS485 + and must be on the same pair (example Green & White). The REF terminal and the cable screen must be connected to the GND terminal (0V) at the Master ACU ONLY, as shown in the full wiring diagram (see centre pages). A correctly wired RS485 data line is shown in the diagram below. Step 4: Connect the Inputs The default function of each input is indicated on the i-net cover (for example, Input 0 = Request to Exit for Door 1). Using these defaults will make system configuration in the Identity Access software very much quicker. These defaults, however, are not mandatory as inputs are fully programmable so any door contact, alarm signal, REX etc. can be connected to any input. The function of each input is then programmed via the software (Refer to relevant manuals) Refer to the wiring diagram on the centre pages Step 5: Connect the Outputs The default function of each output is indicated on the i-net cover (for example, Output 0 = Lock for Door 1). Using these defaults will make system configuration in the Identity Access software very much quicker. All outputs are fully programmable so any maglock etc. can be connected to any output. The function of each output is then programmed via the software.

7 7 Step 6: Select the Switch Settings Bank of 2 ACU is NOT at the end of the bus ACU is at the end of the bus When terminating an i-net ACU, ensure that both DIP switches 1 & 2 are in the ON position on the bank of 2 dip switches. By default these are OFF. Bank of 4 On-board (Wiegand) Readers Enabled Master i-net connected to Slave i-nets on Port B On-board (Wiegand) Readers Disabled Master i-net connected to Slave i-nets on Port B On-board (Wiegand) Readers Enabled Master i-net connected to Slave Expanders on Port A On-board (Wiegand) Readers Disabled Master i-net connected to Slave Expanders on Port A Switch 3 MUST always be OFF. Switch 4 MUST always be OFF Each device on the RS485 bus must be assigned with an individual address. The RS485 bus supports up to 16 devices, so the i-net has a 16 position rotary switch marked 0 to F. The table below shows how the switch position relates to the address: Rotary Value A B C D E F 485 Address An i-net connected to the TCP/IP network is regarded as the Master, and must be given address 0. Slave i-nets (or ACUs) must be given addresses other than 0. Always keep a record of the address for each device to avoid duplication.

8 8 i-net Wiring Diagram RS485 Connect GND to cable screen and to REF on appropriate RS485 port Cable Distances Ethernet: 100 metres point to point RS485: Total length 1 kilometre Wiegand: 80 metres Important To prevent back EMF damaging the ACU, ALWAYS install a MOV or diode across the coil of the every lock

9 i-net Wiring Diagram 9 Note Connections for second door not shown

10 10 RJ-45 TCP/IP Cable Wiring Step 7: Connect the LAN The ACU must be connected with CAT5 or CAT6 cable utilising an RJ-45 connector (standard patch lead) into the TCP/IP network via a hub or switch. If you are connecting the PC directly then a crossover cable should be used. Step 8: Connect Power IA-PCB and IA-ACB Connect a power supply to the +12Vdc IN and GND terminals on the i-net controller as shown in the diagram on the centre pages. The power supply must provide a voltage greater than 11.0Vdc on full load, and less than 15.0Vdc on no load. IA-ACU The power supply is pre-wired to the +12Vdc IN and GND terminals of the controller. NOTE: To avoid communications problems, ensure that the GND terminal is connected to the RS485 REF terminal on the i-net Master ACU ONLY as shown in the wiring diagram (see centre pages)

11 Connect Power / Check LED Indications 11 Step 9: Check LED Indications In the top left corner of the i-net there are 3 LEDs (2 red and 1 green) to indicate power. These are all lit solidly during normal operation. 12V - ON if the overall power for the ACU is OK 5V - ON if power for RS485 and Wiegand is OK 3.3V - ON if power for the processor board is OK Each relay output (numbered 0-3) has its own corresponding green LED. When the relay activates, the LED is illuminated. Similarly, each input (numbered 0-4) has its own corresponding red LED. When the input is shorted, the LED is illuminated. The Ethernet (TCP/IP) port has a green LAN Activity LED, this should flash rapidly when the i-net is connected to the network. Group of 4 LEDs Top pair These indicate the RS485 B send and receive data (red LED flashes when data is sent, green flashes when data is received). Bottom pair These indicate the RS485 A send and receive data (red LED flashes when data is sent, green flashes when data is received).

12 12 Frequently Asked Questions Frequently Asked Questions Why are my RS485 devices not polling? What DIP Switches do I need on? How do I reset the IP address of the ACU? When the door unlocks the ACU becomes unresponsive How do I reboot my i-net ACU? Ensure that the Master i-net controller is connected to Slave i-net controllers using RS485 Port B OR to I/O Expanders using RS485 Port A. The GND terminal MUST be connected to the RS485 REF terminal and the cable screen at the i-net Master ACU ONLY as shown in the wiring diagram (see centre pages). Ensure that the 4-way DIP switch is set correctly. Ensure that each device has a unique address on the bus, where address 0 is reserved for the Master i-net ACU. This depends on how the system has been expanded on the RS485 port. Please refer to Page 7. There is a reset button on the right hand side of the board, press and hold for 30 seconds. The i-net should reboot twice, and the IP address returns to its default address ( ). When the Lock changes state, it can generate back EMF, which can damage the ACU. Make sure that every lock has a suppression device (MOV) installed across the power at the lock There is a Power Jumper located just above the Power Input on the ACU Board. If this is removed the board will lose power in a safe manner. Replace the jumper to power the unit up again. Spares Pack The IA-ACU is supplied with a spares pack containing the following items: 4 x MOVs (see page 6 and centre pages) 1 x Battery Leads The IA-PCB and IA-ACB are supplied with a spares pack containing 4 x MOVs (see page 6 and centre pages)

13 Appendix A 13 Wiring for Sigma Lite Readers SIGMA Lite, SIGMA Lite Plus, SIGMA and SIGMA Extreme Readers Signal Connection Colour GND Power GND BLACK +12v Power +12V RED (Optional *) Data 0 Wiegand_Out0 GREEN Data 1 Wiegand_Out1 WHITE Green LED Wiegand LED 2 BLUE * Sigma Series readers can be powered from a +12v source OR can be powered via PoE. The Black MUST be connected whichever method is used to power the reader Always use BELDEN 9538 or equivalent cable between the Morpho wiring and the ACU.

14 14 i-net Configuration Table Master i-net ACU Name IP assigned RS485 Address 0 Channel / Node Door Name RS485 Address Lock Relay (Output) Push Button (Input) Door Contact Reader Port

15 i-net Configuration Table 15 Master i-net ACU Name IP assigned RS485 Address 0 Channel / Node Door Name RS485 Address Lock Relay (Output) Push Button (Input) Door Contact Reader Port

16 i-net Cover Pictograms Caution: The crossed out wheeled bin logo on Controlsoft products indicates that this product should not be disposed of via the normal household waste stream. To prevent possible harm to the environment or human health, please separate this product from other waste streams. For further information, contact your local government office or the retailer where you purchased product. This information only applies to customers in European Union. For other countries, please contact your local government to investigate the possibility of recycling your product. Controlsoft Limited +44 (0) controlsoft.uk.support Information on all our products can be found on our website

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

_ Access control SISTEMAS DE SEGURIDAD

_ Access control SISTEMAS DE SEGURIDAD _ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams

More information

IEI emerge MicroNode Install and Setup Guide. Contents

IEI emerge MicroNode Install and Setup Guide. Contents IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and

More information

ievo ULTIMATE INSTALLATION GUIDE

ievo ULTIMATE INSTALLATION GUIDE ievo ULTIMATE INSTALLATION GUIDE DOC0066 ISSUE: 03 26th April 2017 ievo READER INSTALLATION GUIDE Issue 03 2 ievo READER INSTALLATION GUIDE Issue 03 Contents 1. Introduction 1-1 1.1 Advice on User Registration

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

AX200. Installation Guide

AX200. Installation Guide Axxess Identification Ltd 27-28 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN6 8TZ United Kingdom Tel: +44 (0)1793 784002 Fax: +44 (0)1793 784005 Email: info@axxessid.com May 2008

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

Quick Installation Manual

Quick Installation Manual Quick Installation Manual Please Note: Full Technical guide is located on the DVD if this is your first time installing a Hartmann Controls Access Control System. It is strongly recommended you review

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

WAC-IPMG200 IP Based Access Control System

WAC-IPMG200 IP Based Access Control System WAC-IPMG200 IP Based Access Control System 1. Technical Specifications 2 Door Controller Size (box) 350mm x 360mm x 85mm Temperature -5 C to +50 C Power Main Power : 220-240VAC, 50/50Hz, Power for main

More information

Installation Guide. Avigilon ACM Embedded Controller

Installation Guide. Avigilon ACM Embedded Controller Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM

More information

WELCOME. Network: Only use Shielded CAT5 cable for network communication.

WELCOME. Network: Only use Shielded CAT5 cable for network communication. WELCOME ievo would like to thank you for purchasing our product. This manual is designed to make your installation of our superior biometric reader quick, easy and efficient. Please ensure you check all

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following: ins-016 160499 TOUCHLOCK compact 100-050 TOUCHLOCK compact kit Instructions for the following: 526-886 TOUCHLOCK compact keypad 100-050 TOUCHLOCK compact kit Master code: Document Contents About this product...2

More information

Slimline CW & WW Series

Slimline CW & WW Series Slimline CW & WW Series 1 x 20W COB LED User Manual Convection cooled, no fan! Optional IR remote Order ref: LEDJ90E White housing versions Order codes: LEDJ61-1CW20 Black housing LEDJ61A - 1CW20 White

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic

More information

Controlsoft Identity and Access Management Software Controlsoft Identity Access Management Software

Controlsoft Identity and Access Management Software Controlsoft Identity Access Management Software Controlsoft Identity Access Management Software IA Server Software Installation Guide v8.0.229 2018 Controlsoft Ltd 9010-0050 Issue 6 Page 1 of 39 29/10/2018 Contents 1. Introduction... 3 1.1. PC Specifications...

More information

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Key Switch. Document version: 1.5 (Updated 02 May 2017) Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling

More information

BIO-PRO Standalone / Weigand fingerprint reader

BIO-PRO Standalone / Weigand fingerprint reader BIO-PRO Standalone / Weigand fingerprint reader www.locksonline.co.uk Tel 0845 30 0 0 v 4 x Master Card x0 User Card IP5 DEEE -0 C to +50 C The BIOSYS product complies with Directive 999/5/CE REMINDERS

More information

4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement.

4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement. WELCOME ievo would like to thank you for purchasing our product. This manual is designed to make your installation of our superior biometric reader quick, easy and efficient. Please ensure you check all

More information

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM RTD-RA Installation Instructions 37.50 LEDS 4 3 2 1 D English Installation Instructions 80.00 80.00 ALL DIMENSIS IN MM C realtime Control Systems A B LEDS 4 3 2 1 D S21 J3 J6 1 2 3 4 J5 5 6 7 0V S1 0V

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing Party Par User Manual Order codes: EQLED015 - Black housing EQLED015B - Polished housing Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP!

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

Cluster Controller. Impro (CCM) Cluster Controller Module INSTALLATION MANUAL

Cluster Controller. Impro (CCM) Cluster Controller Module INSTALLATION MANUAL roxyb00t5 MODEL NUMBERS: HCM720-0-0-NN-XX HCM721-0-0-NN-XX HCM722-0-0-NN-XX HCM723-0-0-NN-XX HCM724-0-0-NN-XX HCM726-0-0-NN-XX Cluster Controller SPECIFICATIONS Impro (CCM) Cluster Controller Module INSTALLATION

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

721EX Access Controller Installation

721EX Access Controller Installation 721EX Access Controller Installation 721EX Controller Standalone Controller Specifications Max Card Capacity: 3000 What is included in the box B-Id 721EX controller board RS485/Serial converter USB/Serial

More information

A list of distributors can be found on our website at -

A list of distributors can be found on our website at - 8/04/203 Ins-30075-EX Net2 nano control unit Paxton For technical help please contact your distributor A list of distributors can be found on our website at - http://paxton.info/508 Documentation on all

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Metra NET Network Installation Manual

Metra NET Network Installation Manual Metra NET Network Installation Manual Table of contents Metra NET Network Installation Manual... 4 Metra NET Network description... 4 Terminology... 5 Network installation products... 6 Network Splitter...

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR-

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series One Door TCP/IP Web Server Controller Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- Table of Contents 3 01- Introduction 4 02 - Overview 4 02.1

More information

Saturday from 09:00-13:00 (GMT) Documentation on all Paxton products can be found on our website -

Saturday from 09:00-13:00 (GMT) Documentation on all Paxton products can be found on our website - 26/0/200 Ins-30075 Net2 nano control unit Paxton Technical Support 0273 80 support@paxton.co.uk Technical help is available: Monday - Friday from 07:00-9:00 (GMT) Saturday from 09:00-3:00 (GMT) Documentation

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

Access Terminal IF-800

Access Terminal IF-800 95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

Keep all manuals as a product component during the life span of the product. Pass all manuals to future users / owners of the product.

Keep all manuals as a product component during the life span of the product. Pass all manuals to future users / owners of the product. KC1 Quick Start Edition: June 2012, Revision A Valid for Hardware Revision A Patents Pending Part Number 903-400000-00 Keep all manuals as a product component during the life span of the product. Pass

More information

RTD-NET Installation Instructions

RTD-NET Installation Instructions LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND

More information

What is Zip? Zip Modules... 6 Zip Network... 6 Zip Master Quick Start... 7

What is Zip? Zip Modules... 6 Zip Network... 6 Zip Master Quick Start... 7 Zip Manual Control systems need connections to the real world -- inputs to measure the environment and outputs to control equipment. Zip is North s measurement and control system. This document relates

More information

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

Installation Instructions (KF-2000)

Installation Instructions (KF-2000) VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

UV Spectra Batten 12 x 5W UV LEDs

UV Spectra Batten 12 x 5W UV LEDs UV Spectra Batten 12 x 5W UV LEDs User Manual Convection cooled, no fan! Optional IR remote Order ref: LEDJ90E Order code: LEDJ98 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL

More information

Lab 5: Access Control Training Station

Lab 5: Access Control Training Station Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand

More information

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras

More information

BioPointe Reader Installation Guide

BioPointe Reader Installation Guide BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial

More information

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01 Comfort, the Intelligent Home System Comfort Fingerprint Reader Interface FPR01 Introduction to the Comfort Fingerprint Reader Interface... 1 Specifications... 2 Equipment... 2 Settings... 2 Connections...

More information

Simple Card Reader for Door Access & Time Attendance System. User Guide

Simple Card Reader for Door Access & Time Attendance System. User Guide Simple Card Reader for Door Access & Time Attendance System User Guide 3 CHAPTER 1 GETTING STARTED Viewing the User Guide in the Internet Included Accessories Included Printed Materials Activating m-kadex

More information

Agenda. August 23, 2017 Slide 2

Agenda. August 23, 2017 Slide 2 Welcome IP Basic Agenda 01 Product portfolio 02 Planning (1) power consumption rule (2) distance rule 03 Commissioning (1) device detail (2) commission overview a. addressing b. programming access 04 Typical

More information

Blitzer Strobe. User Manual. Order code: EQLED366

Blitzer Strobe. User Manual. Order code: EQLED366 Blitzer Strobe User Manual Order code: EQLED366 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

User Manual SOLOgarde

User Manual SOLOgarde User Manual SOLOgarde Stand Alone Access Control System To Register your Product, Visit http://www.tdsi-product-registration.co.uk HELP US TO HELP YOU Every effort has been made to provide you with error

More information

MRC350 Card Capture Reader

MRC350 Card Capture Reader MRC350 Card Capture Reader INSTALLATION GUIDE REF No.: DOC0071 ISSUE: 1.3 6th Aug 2015 2 Contents MRC350 INSTALLATION GUIDE 1. OVERVIEW 1-1 1.1 Card Types and Controller Interfaces 1-1 1.2 Basic Operation

More information

TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24

TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24 TKL19 (RTUL19) Installation Manual Tema1.0_L19_IM_1.0_EN Pagina 1 di 24 CONTENTS 1.1 Wall Set Up for the Cable Trays... 3 1.2 Electrical Connections... 4 1.3 LONWORKS Data Cables... 6 1.4 Mounting the

More information

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING

More information

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.

More information

Installation & User Manual V2.08

Installation & User Manual V2.08 YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

CA111x-series Arming Station

CA111x-series Arming Station GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4

More information

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

Zodiac FR100 TM INSTALLATION MANUAL

Zodiac FR100 TM INSTALLATION MANUAL Zodiac FR100 TM INSTALLATION MANUAL June 2014 Table of Contents INTRODUCTION... 3 SPECIFICATIONS... 4 Diodes... 5 Terminal Strips and Cable... 5 READER LAYOUT... 6 READER INSTALLATION... 7 Mounting Plate...

More information

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi. SETUP GUIDE INSTALLATION HANDBOOK For Integrators, Installers and Administrators Everything on how to get Kisi up and running getkisi.com 1 TABLE OF CONTENT 13 14 INSTALLING KISI AS A STAND-ALONE SYSTEM

More information

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

installation quick guide integrated access control & environmental monitoring

installation quick guide integrated access control & environmental monitoring installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

USB 3.1 CAT6A/7 EXTENDER

USB 3.1 CAT6A/7 EXTENDER USER MANUAL ICU504A USB 3.1 CAT6A/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM Power Mode Config Status Link Video USB 2 USB 3 Power Mode Config Status Link Video USB 2 USB 3 TABLE OF CONTENTS PRODUCT OPERATION

More information

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire

More information