Contents. Preface Safety Instruction Specifications Measuring Principles Parameter Flags... 33

Size: px
Start display at page:

Download "Contents. Preface Safety Instruction Specifications Measuring Principles Parameter Flags... 33"

Transcription

1 User s Manual Medonic CA620 + MPA + AD Medonic CA620 + MPA Medonic CA620 Medonic CA530 + MPA + AD Medonic CA530 + MPA Medonic CA530 Medonic CA620-CellGuard + MPA + AD Medonic CA620-CellGuard + MPA

2

3 Contents Preface Safety Instruction Intended Use Counter Indications Warranty Limitations General Warnings Emergency Procedure Warning Signs in Manual Signs on Equipment Specifications General Description of Available Parameters Short-List of Specifications Parameter Ranges Reagents and Reagent Consumption Limitations Differences between CA620 and CA530 (9,16,20 parameters) Measuring Principles RBC,WBC and PLT Concentration Detection Sizing RBC, WBC and PLT Counting Time RBC & WBC WBC Differentials MCV (Mean Cell Volume RBCs) RDW% (Red Cell Distribution Width) RDWa (Red Cell Distribution Width Absolute) HCT (Hematocrit) PLT (Platelets) MPV (Mean Platelet Volume) PDW (Platelet distribution width) LPCR (Large Platelets) PCT (Packed Platelet Volume) HGB (Hemoglobin Concentration) MCH (Mean Cell Hemoglobin) MCHC (Mean Cell Hemoglobin Concentration) Parameter Flags TU (Time-out Upper Detector) TL (Time-out Lower Detector) SE (Statistical Error) DE (Distribution Error) FD (Floating Discriminator) OF (Offset error HGB) LO (Low blank level HGB) HI (High blank level HGB) NG (Negative HGB) SE (Statistical error HGB) TB (Air bubbles)

4 4.12 NM, OM, TM, BD (WBC Differential Flags) RP (Red Cells Present) EC (Expired control) Comments on Flagging Capabilities Installation Unpacking the Instrument Working Conditions Mechanical Check and Set-Up Front Panel and Command Keys Filling the system with reagents Initial System Configuration CA620-CellGuard Setting up the CA620-CellGuard for Pre-Donor Screening Setting up the CA620-CellGuard for PLT Concentrate CA620/ Setting Date and Time Printer Configuration Select Language Select Units Routine Operation Background Check Analysing the Sample (Open Tube) Analyzing the Sample (Pre-Dilute) Analysing the Sample (Micro Pipette Adapter, MPA) Analysing the Sample (Cap Piercing Device) Advanced User Options (CA620-CellGuard) User Interface Sample Memory Setup Menu Setup Menu Warning Displays Warnings Related to the MPA and Pre-Dilute Inlet Stand-By Mode Reagent Empty Printer and Serial Output Auxiliary Warnings/Messages Calibration and controls Introduction Use of Calibrators and Controls Calibration on a Known Sample Calibration Through a Certified Calibrator Calibration on Pre-Diluted Capillary Blood Calibration of the MPA Calibration of RDW, LYMF and GRAN

5 11 QC and Blood Controls Introduction Initializing the Levey-Jennings Plots and Functions Use of Blood Controls and Levey-Jennings Plots Initialization and Use of X-B Function Display of Blood Control Data Printer and Serial Output Selecting the Correct Printer Type The Serial Output/Hardware Connections The Serial Output Format Maintenance, Shut-Down & Transport Daily Maintenance Monthly Maintenance Three (3) Month Maintenance Short Term Transport Re-packaging and Long Term Transport Permanent Shut-Down and Storing the Instrument Disposal information Trouble Shooting Counting Time HI (TU & TL) Counting Time LO HGB Value Flagged with LO HGB Value Flagged with HI HGB Value Flagged with OF High Background PLT Indication Number XXX Displayed Cell Diff. Only on a Few Samples Cap Piercing Device Clogging in Aspiration Tube Index

6

7 Preface Name of product, serial number and software version This manual describes: CA620, CA530 and CA620-CellGuard as well as the optional devices Closed Tube Adapter (Cap Percing Device) and MPA (Micro Pipette Adapter) Serial number of the instrument is found on the serial plate on the rear of the instrument. Software version is displayed on the main menu in the upper right corner of the display, see picture below marked A A 1177en.gif Other documentation related to this manual: Additional applications and notes, as well as service manual, product data sheets on reagents and calibrators are available from your local distributor and listed on the Boule support server, which is exclusively available to your authorized distributor. Specimen, special conditions of collection and storage conditions General instructions for (human) blood collection, handling, storage of samples etc. are described in the booklet Hematology for sales and service engineers which is available from your authorized distributor. Operator training Additonal operator training is not required under the following conditions: 1. The operator must have basic scills in working under laboratory conditions. 2. The operator must have basic scills in hematology. 3. The operator must be aware of IVD(EU) and FDA(USA) requirements regarding laboratory equipment for In Vitro Diagnostic purposes. 4. The operator must read and understand this manual. Component lists, tools and other consumables These are listed, including their special functions, in the Service Manual distributed on CD-ROM and available via the Interrnet on-line to your authorized distributor. 1176en

8 Name and address of manufacturer: Boule Medical AB P.O. Box SE Stockholm Sweden Telephone: Fax: info@bm.boule.se Name and address of distributor Distributors are listed on: http.// Standards EN591:2001 IVD 98/79/EG SSEN (Low Voltage 73/23/EEC) EN (1997) with amendment EN 61326/A1 (1998) (EMC 89/336/EEC) Standards harmonized with FDA/UL Manual number en Date of issue August en01

9 1 Safety Instruction 1.1 Intended Use CA620/530 and CA620-CellGuard The CA620/530 is a fully automated hematology analyser used for in vitro diagnostic testing of whole blood specimens under laboratory conditions. The user must have basic skills in laboratory practice and must be aware of the guidelines in Good Laboratory Practice. The CA620-CellGuard is intended to be used especially in blood banks as pre donor screening as well as a quality control tool for PLT concentrates in a blood bank production facility. During the installation and set-up, the CA620-CellGuard can be configured either for pre-donor screening, in which the instrument is fully identical to the CA620, or for quality control to measure PLT concentrates. 1.2 Counter Indications Do not use the instrument outdoors. Usage outside the specified temperature and humidity range might result in instrument malfunction or short circuit. - Turn off the power immediately and contact your service department. Do not modify the instrument. Modification without written instructions from the manufacturer might cause erroneous results or risk for electrical shock. Do not remove the cover. Only authorized service personnel is allowed to open the instrument. Do not use the instrument for other purposes then as indicated in this manual. 1.3 Warranty Limitations Service and instrument maintenance must be performed by Boule Medical AB or authorized service personnel. (Referred to hereafter in this manual as Boule). Use only original spare parts and by Boule authorized reagents, blood, calibrators and cleaners. Boule has designed the Medonic instruments as systems for optimal performance. Substituting reagents, calibrators, controls, and components not recommended by Boule may adversely affect the performance of the instrument. If the substituted products are defective or adversely affect the performance of the instrument it may void your warranty. Each Boule system is tested at the factory using our recommended reagents, calibrators and controls, all performance claims are generated as part of this complete system. System operators and laboratory supervisors are responsible that Boule products are operated and maintained in accordance to the procedures described in the Product Labelling (manuals, package inserts and bulletins of any kind). They are also responsible for determining that product performance conforms to the applicable claims. 1070en

10 Safety Instruction If, under these prescribed conditions of operation and maintenance, an aberrant or abnormal result occurs, as defined by the laboratory protocol, laboratory personnel should first make certain that the system is performing and is being operated in accordance with the Product Labelling. The laboratory protocol should than be followed to advise the clinician in case a result appears to have deviated from the norms established by the laboratory. Boule products do not make diagnosis on patients. Boule intends its diagnostic products (systems, software and hardware) to be used to collect data reflecting the patient's hematological status at a certain point of time. Such data may be used in conjunction with other diagnostic information and with the attending physicians evaluation of the patients condition to arrive at a diagnosis and a clinical course of treatment. 1.4 General Warnings Boule incorporates safety features within the instrument in order to protect the operator from injury, the instrument from damage and the test results from inaccuracies. Electrical hazard Do not spill blood, reagent, drop metal objects such as wire staples or paper clips into the instrument. This might cause a short circuit. If this should occur, turn off the power immediately and contact your service department. Note: The cover should only be opened/removed by authorised service personnel. Do not touch the electrical circuits inside the cover. There is a hazard of electrical shock. Note: The cover should only be opened/removed by authorised service personnel. Potentially biohazardous material Because no test method can offer complete assurance that HIV, Hepatitis B or C viruses, or other infectious agents are absent, these products should be handled at the Biosafety Level 2 as recommended for any infectious human blood specimens in Protection of Laboratory Workers From Infectious Disease Transmitted by Blood, Body Fluids and Tissues- 2nd Edition, Tentative Guidelines(1991) Document M29-T2 promulgated by the National Committee for Clinical Lab. Standards in the U.S.A. (NCCLS) Contamination hazard Always wear protective gloves and/or goggles when handling infectious or potentially infectious materials. Handle samples with great care. There is a risk of infection if contaminated blood splashes. - If blood splashes, enter your eye or a cut, wash it off with plenty of water. Do not touch the waste liquid when discarding waste or disassembling/assembling the related parts outside the instrument. Risk of infection from contaminated blood. -If you should touch the waste liquid inadvertently, wash off with disinfectant first, then wash it off with soap en01

11 Safety Instruction When handling reagents. - If a reagent happens to enter your eye, wash it off immediately using plenty of water and take action to seek medical treatment at once. - If it happens to adhere to the hand or skin of other body parts, wash it off using plenty of water. - If you should swallow it inadvertently, take action to seek medical treatment at once. Crush hazard Always switch off the instrument when opening the front door. crush hazard can occur if the option Cap Piercing Device is installed in the equipment. See Signs on Equipment on page 12. Note: The cover should only be opened/removed by authorised personnel during operation. 1.5 Emergency Procedure In case of emergency due to an obvious malfunction of the instrument e.g. smoke or liquid coming out from the inside, proceed as follows: 1. Switch off the instrument immediately by: Pulling out the mains cord from the mains supply. 2. Contact your authorized distributor s service department immediately. 1.6 Warning Signs in Manual These warning signs in the manual are used to identify possible hazards and to call the operators attention to the existence of this condition. Warning Caution Important Indicates operating procedures, practices and so on, that could result in personal injury or loss of life if not correctly followed. Indicates operating procedures, practices and so on that could result in damage or destruction of equipment if not strictly observed. Emphasizes operating procedures, practices and so on that must be followed to avoid erroneous results. 1070en

12 Safety Instruction 1.7 Signs on Equipment 1 Front/side view of the Instrument jpg Open door view of the Instrument jpg Back view of the Instrument jpg 1. This label indicates that the safety instructions in the manual must be read before opening the front door of the instrument. 2. This label indicates a potential bio hazard due to blood exposure or possible contaminated waste. 3. This label indicates a potential crush hazard. Disconnect the instrument from the mains outlet before opening the front door. Only authorized personell are allowed to open front door. 4. Serial Number, Voltage/Fuse specifications and CE / UL markings en01

13 2 Specifications 2.1 General The operator works with a menu from which the desired program is chosen, e.g. discriminator settings, calibration, cleaning etc. Two external reagent reservoirs are used: Isotonic diluent. Hemolyzing reagent. Whenever one of these external reservoirs is empty, this is indicated on the display. The instrument also performs a 3-part WBC differential by means of a cyanidefree hemolyzing reagent. A sample memory is available, protected against mains power failures. Sample search, selective printing and QC options are available. The instrument is a fully automated hematology analyser designed to measure up to 20 parameters using whole blood from an open inlet, closed tubes, micro pipettes 20µl or pre-diluted blood. 2.2 Description of Available Parameters The number of Red Blood Cells (RBC) The number of White Blood Cells (WBC) The number of Platelets (PLT) The Mean Cell Volume of Red Cells (MCV) The Mean Platelet Volume (MPV) The Hemoglobin Concentration (HGB) The size distributions of PLT, RBC and WBC are measured at the same time as the above-mentioned parameters. Hematocrit (HCT) The Mean Cell Hemoglobin (MCH) The Mean Cell Hemoglobin Concentration (MCHC) The Red Cell Distribution Width (RDW%) The Lymphocyte concentration in absolute number and percentage The MID-sized Cells (e.g.monocytes) in absolute number and percentage The Granulocytes concentration in absolute number and percentage (LYMF) (MID) (GRAN) The Red Cell Distribution Width (Absolute) (RDWa) 1001en

14 Specifications The Platelet Distribution Width (Absolute) (PDW) The Platelet Macro Range > 12 fl in% (LPCR) The Platelet Packed Volume (PCT) The instrument employs the electronic impedance principle for cell counting and sizing, and a colorimetric method for measuring hemoglobin. A microprocessor is used to measure the parameters and to size the cells. During the count the processor is checking the analysing process for any irregularities. Size distributions are printed for all populations (RBC, PLT and WBC). The instrument has as standard a parallel and a serial output, which is user programmable. From a built-in selectable program the user can choose between different print formats. A bar-code reader (scanner), available as an option, can be connected to enter the sample ID automatically. The instrument is fully automatic, which means that, the system is always powered on and performs automatically preforms check- and cleaning cycles to minimize user maintenance. Note: PCT, LPCR, RDWa and PDWa are not established parameters. Their use should be restricted to research or investigational use only. 2.3 Short-List of Specifications Measuring principle RBC, WBC, PLT Measuring principle HGB Discriminator Sampling system Parameters reported Impedance Size distributions printed for Aspirated blood volume (open tubes) Aspirated blood volume approx. 200 µl (closed tubes) 1 Blood volume using the 20 µl Micro Pipette Adapter Pre-diluted mode CA530 Screen CA620 Screen Keyboard Total cycle time Cyanide free method 540nm Floating programmable Closed shear valve RBC, MCV, HCT, PLT, MPV HGB, MCH, MCHC, WBC, RDW%, LYMF abs, MID abs, GRAN abs., LYMF%, MID%, GRAN% RDW abs, PDW abs, LPCR, PCT RBC, PLT and WBC diff. approx. 125µl 1:200 to 1:250 using min. 20µl blood e.g. 20 µl to 5 µl diluent 30 µl to 6 µl diluent 40 µl to 8 µl diluent 2x40 character LCD Graphic LCD display Numerical approx. 73 seconds Important Applicable for CA620- CellGuard: The MPA is intended to be used for pre-donor screening. Using the MPA for PLT concentrate may reduce the accuracy of the result en01

15 Specifications Sample display and print after approx. 53 seconds Printer External, IBM proprinter, Epson format, HP-PCL or DPU411-type II /DPU414 supplied by Boule-Medical CA530 Memory >350 samples CA620 Memory >200 samples and 600 control samples CA530 QC capability SD, CV, Xm CA620 QC capability SD, CV, Xm, Levey-Jennings plots and X-B with approx samples history HGB correction on high Yes WBC counts Warning flags on parameter abnormalities Yes Floating discriminator RBC/ PLT Yes (position printed) Mathematical 3-part diff. WBC calc. Yes Automatic HGB blank on each Yes sample Carry Over < 1% Bar-code reader input Yes Serial output 2 Yes Mains voltage / Fuses 230V Fuse 5x20mm T2A 120V Fuse 5x20mm T4A Mains voltage tolerances +15% / -15% Power consumption max 250 VA Power consumption (stand-by) max 50 VA Frequency 50/60 Hz Built-in test /adjustment programs Yes Temperature 18-32C, 64-90F Humidity (none condensing) 20-80% Dimensions H= 350,W=420, D=460 (mm), H= 13.8, W=16.5, D=18.1 (inch) Weight (net) approx. 22 Kg, 48.5 Lbs 1. Optional device 2. Computer & connection must conform to standard EN en

16 Specifications 2.4 Parameter Ranges Linearity +/-1% within the following range: WBC RBC MCV PLT HGB PLT-Concentrate mode (RBC < 0.3 and measured on a Latex solution) Measuring range: (applicable on CA620-Cellguard only) WBC RBC (CA620-Cellguard) RBC (CA620/530) MCV PLT HGB PLT Concentrate mode (applicable on CA620-Cellguard only) Correlation 1 RBC, WBC R > 0.97 PLT R > 0.90 HGB R > 0.99 MCV R > 0.90 Reproducibility (typical): Measured as an average of 10 measurements each of 10 different vein K2- EDTA collected normal samples: Parameter X-mean (CGS units) CV(%) WBC RBC MCV PLT HGB Using Coulter AcT and Abbot CD1600 as reference en01

17 Specifications Caution Use only by Boule authorized reagents. Erroneous results and damage of the system may occur if other reagents are used. 2.5 Reagents and Reagent Consumption The reagent consumption is depending on the total number of samples/day. Using the system for more than ca. 50 samples/day; the reagent consumption will be: Diluent Lyzer approx. 19 ml/sample approx. 9.5 ml/sample The approximate consumption can be calculated from the graph below and is depending on the number of samples/day. The figures stated are indicative only and assumes maximum 2 blank counts per day. As seen from the graph, the relation Diluent/Lyzer is 2:1 in case of 50 samples/day or more. Hence, using the instrument for less number of samples/day, less Diluent is consumed in relation to the lyzer Diluent consumption CA620 vs # samples Diluent consumption / sample (ml) Number of Blood_samples/Day 1014.eps Diluent Consumption Lyzer consumption CA620 vs # Samples Lyzer consumption / sample (ml) Number of Blood_samples/Day 1015.eps Lyzer consumption For additional information regarding cleaning solutions; please refer to Maintenance, Shut-Down & Transport on page en

18 Specifications 2.6 Limitations Verification of any abnormal test result (including flagged results or results outside of the normal range) should be performed using reference methods or other standard laboratory procedures for the conclusive verification of results. The section below list known limitations of automated blood cell counters in general as well as specific issues for cell counters using the impedance technology. WBC White Blood Cells (Leukocytes) WBC that exceeds the linearity limits of the system will require dilution of the blood sample. Re-assaying the diluted sample will help to obtain the correct assay value. NRBC Immature Nucleated Red Blood Cells will be counted in the WBC parameter. If the number of the NRBC is sufficient to activate the DE alarm, such interference will be detected. However, the manual differential blood cell count, performed on a stained blood film, will reveal the presence of NRBCs. Unlyzed Red Cells In particularly rare instances, the RBC in the blood sample may not completely lyze. These non-lyzed cells may be detected on the WBC histogram with a DE alarm or as an elevated baseline on the side of the lymphocyte population. Nonlyzed RBCs will cause a falsely elevated WBC count. (See also NRBC above) Multiple myeloma The precipitation of proteins in multiple myeloma patients may give elevated WBC counts. Hemolyzis Hemolyzed specimen contains red cell stroma (debris), which may elevate the WBC and/or PLT count. Leukemias This disease state may result in a spurious low WBC count because of the possible increased fragility of the leukocytes leading to some destruction of these cells during counting. The cell fragments will also interfere with the white cell partial differential parameters (LYMF, GRAN and MID). A spurious low WBC count may also be seen in patients with lymphocytic leukemias due to the presence of abnormally small lymphocytes, which may not be counted by the instrument. Chemotherapy Cytotoxic and immunosuppressive drugs may increase the fragility of the leukocytes, which may cause low WBC counts. Cryoglobulins Increased levels of cryoglobin that may be associated with myeloma, carcinoma, leukemias, macroglobulinemia, lymphoproliferative disorders, metastatic tumours, auto immune disorders, infections, idiopathic disease, aneurism, pregnancy, thromboembolic phenomena, diabetes etc. and may cause elevated levels of WBC, RBC or PLT counts as well as HGB. The specimen can be warmed up to 37 C and re-analysed immediately or a manual WBC, RBC or PLT count can be performed en01

19 Specifications RBC Red Blood Cells (Erythrocytes) The red blood cell dilution contains all the cellular elements of the blood, RBC, WBC and PLT. During the counting platelets, are not counted since the size falls below the threshold (discriminator). Leukocytes however, are always included in the RBC count. Since the concentration ratio between RBC and WBC is normally ca. 1000, the introduced error is almost negligible. In case of high WBC counts with low RBC, the RBC count may be corrected by simply subtracting the WBC from RBC. Agglutinated red blood cells This might cause a falsely decreased RBC count. Blood samples containing the agglutinated red blood cells may be identified by observing abnormal MCH and MCHC values as well as by examination of the stained blood film. Cold agglutinins IgM immunoglobulins which are elevated in cold agglutinin disease may lower RBC and PLT counts and increase the MCV. HGB (hemoglobin) Turbidity of the blood sample due to any number of physiological and/or therapeutic factors may produce falsely elevated HGB results. The CA620/530 however is compensated for this effect with high WBC counts up to WBC approx e3/µl. In case of extreme WBC counts, the following is recommended: 1. Elevated WBC The diluted sample should be centrifuged and the supernatant fluid checked on a spectrophotometer for turbidity. 2. Elevated lipids Elevated lipids in the blood sample will give the plasma a milky appearance. This condition can occur with hyperlipidemia, hyperproteinemia and hypobilirubinemia. Accurate HGB determination can be achieved by using reference methods and a plasma blank. Increased turbidity may also be seen in cases where the red blood cells are resistant to lyzing. This condition will cause a falsely elevated HGB result but can be detected by monitoring the MCHC. Fetal blood The mixing of fetal and maternal bloods may produce a falsely elevated HGB value. HCT (Hematocrit) As HCT is the product of MCV x RBC, any erroneous result in MCV and/or RBC will produce an equal error in the HCT parameter. Red blood cell agglutination May produce an erroneous MCV value and therefore a false HCT WBC An excessive number of WBCs might cause interference within the RBC population and therefore a false MCV value. PLT Excessive numbers of PLT, in most cases, do not interfere with the MCV parameter due to the use of the floating discriminator technology in the instrument. 1001en

20 Specifications RDW (Red Cell Distribution Width) The red cell distribution width is a function of the RBC count and derived from the RBC histogram. In most cases, any error introduced in the MCV may also cause the RDW to be erroneous. Especially blood transfusions may raise the RDW significantly due to the presence of bi-modal populations. PLT (Platelets or Thrombocytes) Very small RBCs might elevate a PLT count. This effect is minimized in the instrument due to the use of a floating threshold (discriminator). By observing the PLT and RBC histograms, this effect is seen as an overlapping PLT/RBC area. Agglutinated RBCs Agglutinated RBCs might trap platelets and may give an erroneous low PLT count. The presence of agglutinated RBCs is detected by monitoring the MCHC parameter and by careful examination of the stained blood film. Giant platelets in excessive numbers This may cause a low PLT count since they might fall within the RBC threshold range. Chemotherapy Cytotoxic and immunosuppressive drugs may increase the fragility of these cells, which may cause low PLT counts. Reference (manual) methods may be necessary to obtain an accurate platelet count. Hemolyzis Hemolyzed specimens contain red cell stroma, which may elevate platelet counts. A.C.D. blood Blood anti coagulated with Acid Citrate Dextrose may contain platelet aggregates, which could depress the platelet count. RBC inclusions Erythrocyte inclusions may also produce a spuriously increased platelet count. (e.g. Howell-Jolly bodies, siderotic and basophilic granules) Platelet agglutination Clumped platelets due to poor collection techniques or platelet satellitosis caused by EDTA activation of immunoglobulins may cause a decreased platelet count and/or an elevated WBC count. The specimen should be recollected in sodium citrate anticoagulant and re analyzed for only the platelet count. The final PLT result must be corrected for the sodium citrate dilution effect en01

21 Specifications MPV (Mean Platelet Volume) Giant platelets Large platelets counted as RBCs will fall outside the PLT range and therefore lower the MPV. Small erythrocytes Very small RBCs might fall into the PLT region and might be counted as PLTs and therefore influence the MPV parameter. (This effect is minimized in the instrument due to its floating threshold system) Agglutinated erythrocytes This may trap platelets and therefore affect the MPV parameter. Note that agglutinated erythrocytes may be detected by carefully examine the MCHC parameter and/or the stained blood film. Chemotherapy May also effect the size of the PLTs EDTA Note that all samples collected in EDTA will not maintain a stable MPV. The PLTs will swell as a function of time and temperature. LYMF (Lymphocytes) The lymphocyte count is derived from the WBC count. The presence of nucleated red cells (NRBC), certain parasites and erythrocytes that are resistant to lysis may interfere with LYMF count. MID (MID sized area) The mid size area consists mainly of Monocytes. The presence of large Lymphocytes, atypical lymphocytes, blasts, and excessive number of basophils may interfere with the MID area. GRAN (Granulocytes) The granulocyte cell count is derived from the WBC count. The presence of excessive numbers of metamyelocytes, myelocytes, promyelocytes, blasts and plasma cells may interfere with an accurate granulocyte count. 1001en

22 Specifications 2.7 Differences between CA620 and CA530 (9,16,20 parameters) The CA620 and CA530 have identical parameter performances in all respects. The differences are the following: -The INTRA mode, see section Analysing the Sample (Open Tube) on page 54 and Block parameters see section Block parameters on page 72 are not available on the CA530. The CA620 has an extended calibration menu, see Calibration Through a Certified Calibrator on page 83. The CA620 has an extended QC function including X-B and Levey-Jennings Plots. See Introduction on page 87. The CA530 employs a 2 x 40 alphanumeric display and the CA620 is equipped with a graphic display making, a graphic display of the size-distribution curves, possible. Extended print format is available on the CA620 only. See appendix available from your authorized distributor. The CA620-CellGuard can be configured as a donor screening device or as a tool to determine the PLT concentrations in PLT bags. In case the instrument is used for donor screening, it is fully identical to a CA parameter machine. The CA620 differs from the CA530 by the specially designed front panel and keyboard en01

23 Specifications The menu numbering for the CA620, CA620-CellGuard and CA530 is identical. This user manual is therefore applicable for both type of instruments. The following table shows which parameters are available on the 9, 16 and 20 parameter models: CA530-9 CA CA CA CA RBC yes yes yes yes yes MCV yes yes yes yes yes HCT yes yes yes yes yes WBC yes yes yes yes yes HGB yes yes yes yes yes PLT yes yes yes yes yes MPV yes yes yes yes yes MCH yes yes yes yes yes MCHC yes yes yes yes yes RDW% no yes yes yes yes LYMF% no yes yes yes yes MID% no yes yes yes yes GRAN% no yes yes yes yes LYMF no yes yes yes yes MID no yes yes yes yes GRAN no yes yes yes yes RDWa no no yes no yes PCT no no yes no yes PDW no no yes no yes LPCR no no yes no yes 1001en

24 Specifications en01

25 3 Measuring Principles 3.1 RBC,WBC and PLT Concentration Detection Detection is accomplished using the electronic impedance principle and occurs in the orifice of the transducer. The blood is diluted to 1:400 (WBC & HGB) and 1:40000 (RBC & PLT) through a precise shear valve system. The shear valve (sampling valve, marked in the figure below) cuts a very reproducible volume (25 µl) from the aspirated blood and dilute with an equal precise volume of diluent (or lyzer) to achieve the final dilution rates. Sampling valve 1017.wmf Two separate measuring chambers and transducers are used, one for RBC/PLT and one for WBC/HGB analysis. This excludes any possibility of cross contamination between the lyzer and the RBC/PLT dilution. A pressure is applied on top of the diluted sample and the diluted sample is pressed through an orifice (aperture) of 80 µm diameter. Each side of the orifice is equipped with a platinum electrode and an electrical current is applied between the electrodes. When a cell is drawn into a constant current, flowing from an electrode through the orifice to a second electrode, the electrical conductivity changes. This generates an equivalent voltage pulse. The amplitude of the pulse is directly proportional to the volume of the represented cell. The number of pulses corresponds to the number of cells detected. Coincidence corrections are made within the software of the instrument, giving the instruments a full linear range within the specifications. 1016en

26 Measuring Principles electrical current electrodes A cells Flow direction A=Aperture 1018.tif The PLT, RBC and WBC parameters are measured on a precise aliquot of the sample. The amount of sample measured is determined by the volume of a precise glass column; called a metering tube. Two optical detectors are used to start and stop detection. The start detector is activated by the flow of the isotonic diluent through the metering tube. As the meniscus passes the optical path it causes a voltage change that activates the count and sizing circuitry of the system. As the isotonic diluent continues to flow upward into the metering tube it passes the stop detector. This action stops the count and analysing process and the parameters and distribution curves are displayed (and automatically printed if so programmed by the user). Due to this principle, the CA instruments perform absolute counts related to fixed volumes. glass tube stop detector flow fixed volume start detector 1019.tif The instruments use a lower discriminator level at approx. 2.5 fl. All cells over this level are analyzed and the counts are stored. The user defines, by means of setting the discriminator level(s), which cell is seen as a PLT or as a RBC cell. A red blood cell is defined as a cell with a volume larger than the upper PLT programmable discriminator level en01

27 Measuring Principles All cells smaller than the upper PLT discriminator level will not be recognised as red cells. In case the user has selected a floating discriminator; RBC cells are counted from the set-point of this variable discriminator, which varies from sample to sample between the volume limits set by the user. The number of cells for determining RBC is counted from a suspension of 1: dilution ratio of whole blood. Let us suppose that a sample contains cells/µl. A dilution of 1: then give a final concentration of divided by = 125 cells/µl, so each µl drawn through the aperture generates 125 pulses. The measured volume drawn through the aperture is 270 µl (factory calibrated), so the system will count 270*125 = pulses. The analyzer uses a fixed division factor of 67.5, so the display will show /67.5 = 500, which is the correct value. With the size of the orifice and the concentration of cells, there will be a certain coincidence in the orifice system. However this is a constant system factor and compensated within the software by a correcting algorithm to make the RBC count linear within the stated specifications. Hence, the total number of cells passing through the aperture when determining the RBC is the value on the display multiplied by the factor Therefore, a sample which gives 5.00 in the RBC display field has been analyzed by measuring 500 * 67.5 = cells. The reproducibility is directly related to the total number of cells entering the orifice. The higher the concentration, the better the reproducibility. The instrument has a dilution ratio for RBC of 1: and the CV will therefore be less than 1% for samples with an RBC number within the normal range. 3.2 Sizing RBC, WBC and PLT The sizing is done in a matrix with the volume on the horizontal (x-) axis and the number of cells on the vertical (y-) axis. (The x-axis is divided into 2048 channels) As stated above, a size distribution is performed for both PLT and RBC simultaneously. The 'RBC' distribution however, is the distribution with a higher volume than the upper discriminator level which is marked on the display and printer as a dotted vertical bar. The maximum (RBC) cell size that can be analyzed is 250 fl. Clumps of cells larger than this volume are analyzed as being 250 fl and are 'collected' in the highest channel. As the curves are 'normalised', the height of the distribution curve is not necessarily related to the number of RBC cells counted. The reproducibility of the curve is also dependent upon the concentration of cells in the sample. In cases with a low number of RBC cells there might be some slight differences in the shape of the curve from one count to another due to statistical sampling. Sizing of the WBC population is done simultaneously in an equal second matrix. The highest channel represents a volume of ca. 400 fl. As with the RBC/PLT sizing, the reproducibility of the curve is dependent upon the concentration of (WBC) cells in the dilution. 1016en

28 Measuring Principles 3.3 Counting Time RBC & WBC The microprocessor system checks the counting time for the RBC and PLT counting process. The counting time is defined as being the time needed for the sample to be drawn from the start- to the stop detector in the metering unit. See RBC,WBC and PLT Concentration Detection on page 25. A counting time, which is 'HI', may be caused by a blockage in the aperture. In such case, the system rinses the aperture (orifice) automatically. It is advisable to check the counting time by using isotonic diluent as a new sample. (To save the original blood sample). The counting time limits on the RBC/PLT process are 10.5 and 17.5 seconds respectively. Normal counting time is 13.5+/- 2 seconds. If the counting time is outside the limits, the text LO or HI will be displayed. The counting time can be displayed using the left/right arrow keys and is shown as: - RBC-Time= - WBC-Time= Note: The 'Counting time' is not related to the actual result. Atmospheric pressure variations, protein built-up within the orifice (aperture) and other secondary effects that might cause pressure changes will NOT influence the counted parameters RBC, PLT and WBC. 3.4 WBC Differentials Within the 3-part diff. technology a general problem is found how to define the correct settings of the discriminators for the lymphocyte, MID sized cell (mainly Monocytes) and Granulocytes areas. Many analyzers are using a fixed discriminator analogue where fixed thresholds are used to separate the 3 populations. The 3 part. diff. technology is based on the reaction of the lyzer reagent(s) to each specific cell type. Lymphocytes are more lyzed compared to the Granulocytes, resulting in 2 main populations whereof the Lymphocytes will be the smallest. The main problem is related to the Granulocyte population. The cytoplasma surrounding the cells is slowly dissolved in the surrounding plasma in whole blood. This means that the Granulocyte population is slowly collapsing and finally interferes with the Lymphocytes. Refer to the figure below where the same sample is analyzed after approx. 4, or more, hours. It is clearly seen that a fixed discriminator technology is unreliable whenever analysing blood exposed to time, high temperature or other factors that reduce the cytoplasma surrounding the Granulocytes en01

29 Measuring Principles n fixed discriminators 4 hours old fresh blood LYMF GRAN Volume (fl) 1020.tif To overcome the above mentioned problem, the instrument utilizes a so-called mathematical differential, where the curves are analyzed within the software and 3 separate curves are built through a curve fitting method. Hence, the software of the instrument is building an artificial matching distribution around the main populations. To do so, after the analysing process, the instrument finds 2 main modes (= peaks) within the total distribution. Then matching of the 2 main populations takes place including extrapolation to the base line. The remaining area that was not covered by the 2 main populations is now classified as being the MID cell area which mainly consists of the Monocytes. A third population is now calculated, representing this area. The final picture below consists of 3 curves and will be printed exactly this way. It is obvious that this approach is not dependent on the actual position of the 2 main populations and therefore superior to a system using a fixed discriminator technology. n MID cells LYMF GRAN Volume (fl) 1021.tif 1016en

30 Measuring Principles 3.5 MCV (Mean Cell Volume RBCs) The MCV parameter is derived from the RBC distribution curve. As the distribution curve has a maximum volume range of 250fl, the maximum channel also contains clumps of cells that are larger than this volume. Therefore this channel is excluded from the MCV calculation. The MCV is calculated from the volume position of the discriminator to 249 fl. Be aware that the discriminator might be floating or fixed by the user in menu 5.6.x. In general, RBC counts that are lower than 0.60 (displayed value) do not give a MCV/HCT value due to low statistical significance. If the MCV is calibrated by using the Calibration program, found in the Setup menu; the whole curve is recalculated and moved in a correct way that reflects the new calibration setting. The printed curve will therefore always be correct in respect to the actual MCV value. 3.6 RDW% (Red Cell Distribution Width) The RDW% parameter is calculated from the RBC distribution curve. The CV of the curve is calculated. However, the CV is only calculated on a portion of the curve. This avoids that other populations might interfere. The RDW% value is therefore only measured on a portion of the RBC size distribution curve. I.e. not all particles are included in the RDW% calculation. The RDW% parameter is only valid if the MCV value is not zero. 3.7 RDWa (Red Cell Distribution Width Absolute) The RDWa parameter (absolute) is calculated from the RBC distribution curve at a fixed level. In contrast to the RDW% parameter, which is expressed in CV, the RDWa parameter measures the absolute width of the curve. The RDWa parameter is only displayed if the MCV value is not zero. The RDWa parameter is for investigational purposes only. No normal ranges are given. 3.8 HCT (Hematocrit) The HCT is defined as being the packed volume of red cells in whole blood and is calculated through MCV * RBC. If no MCV is derived from a sample due to too low a number of RBC cells, no HCT is calculated. 3.9 PLT (Platelets) Platelets are defined (for the purpose of discrimination) as cells in a range from 2.5fl to the discriminator level that is either set on a fixed volume or floating and determined by the software on each sample. The setting of the upper discriminator is done in the set-up menu 5.6. The platelets are determined from the same dilution as the RBC, in fact, the system is counting just cells during the RBC/PLT counting process. The determination of which cell is a PLT or RBC is done at the end of the counting procedure and fully determined by the setting of the user defined discriminator behaviour (floating or fixed) en01

31 Measuring Principles Let us suppose that a sample contains platelets/µl in whole blood. After a dilution of 1: the sample contains divided by = 5 cells/ µl. So, each µl drawn through the aperture gives 5 pulses. As the counting volume (the volume of the metering glass tube) is 270 µl, the total number of cells that are analyzed will be 5*270=1350 cells. In other words, the total number passing through the orifice when determining the PLT is the value shown on the display screen without decimals multiplied by the factor The reproducibility is directly dependent on the total number of cells entering the orifice. In the instrument, measuring PLT from the same dilution as RBC, the CV will be less than 3.5% for most of the samples within normal range. The CV will be lower for most samples, but on some samples it might be slightly higher. A 'mean' CV of about 3.2% is expected for well-treated fresh EDTA whole blood samples within the range of /µl. As the system uses an orifice size of 80 µm diameter, coincidence losses will take place with extreme sample RBC/ PLT counts. The system has a software with a well-balanced mathematical correction algorithm to minimize these effects Please note that if a floating discriminator is used and no well-defined minimum is found between the RBC and PLTs, the reproducibility of mainly the PLT is affected. To check the reproducibility of the low PLTs, it might be wise to put the analyzer in a fixed discriminator mode to exclude any error introduced by an illdefined RBC-PLT population. CA620-CellGuard PLT (Platelets) In case the CA620-CellGuard is programmed and used for PLT concentrates, the reproducibility is better than the stated CV figures above, as CV is a concentration dependent parameter. Note: In case high numbers of RBCs are present using the PLT concentrate mode, PLT will show a flag RP (Red cells Present) to warn the operator that the PLT parameter may not be correctly analyzed MPV (Mean Platelet Volume) The mean cell volume of the platelets is determined from the PLT size distribution curve. The MPV is defined as being the mean value of the PLT size distribution curve from the lower discriminator (2.5 fl) to the position of the upper discriminator which might be programmed as floating or fixed as set in menu 5.6.x. MPV is not displayed in case of extreme low PLT counts due to high statistical inaccuracy of such a population PDW (Platelet distribution width) The PDW parameter is calculated from the PLT distribution curve at a fixed level. The calulation of the PDW parameter is analogue to the RDWa parameter for RBC. The PDW parameter is only valid if the MPV value is not zero. This parameter is for investigatory purposes only. No normal range is supplied. 1016en

32 Measuring Principles 3.12 LPCR (Large Platelets) The LPCR (Large Platelets Concentration Ratio) parameter is calculated from the PLT distribution curve. Platelets that are larger than 12 fl up to the (floating) discriminator are expressed in % of the total PLT count. The LPCR parameter is only valid if the MPV value is not zero PCT (Packed Platelet Volume) The PCT is calculated as being PCT= PLT x MPV and expressed in % HGB (Hemoglobin Concentration) The hemoglobin is determined from the same dilution as the WBC. For each sample a blank is measured as a reference, this means that any drift in reagentand cuvette-absorption or lamp is eliminated. The photometer system consists of a tungsten lamp, a cuvette with a length of 15 mm and a filter at a wavelength of 535nm (bandwidth 20nm). The HGB readings are slightly corrected for turbidity in case of extreme WBC counts. The lamp is switched off if the instrument is in stand-by-mode, giving it an extended lifetime MCH (Mean Cell Hemoglobin) The MCH is a calculated value and is defined as HGB/RBC giving the mean HGB concentration in each red cell MCHC (Mean Cell Hemoglobin Concentration) The MCHC is a calculated value and is defined as HGB/HCT. The MCHC is calculated from 3 measured parameters and therefore an excellent instrument stability check. MCHC=HGB/HCT HGB/(MCVxRBC). In general it could be stated that if a daily mean value is found outside the range g/dl, the instrument might have been wrongly calibrated. The daily mean value of the MCHC parameter should be /- 1.5 g/dl en01

33 4 Parameter Flags The instrument has several indication- and warning flags related to the measured parameters. The flags are shown on the display as well as printed on the connected printer. An error flag should be seen as parameter value error. The sample should be re-analyzed. A warning flag might indicate a pathological sample. If on the same parameter both an error and a warning flag occurs; the error flag has always a priority and is displayed and printed in the first place. Note that a parameter that is outside the Normal Range which is set in menu 5.4 is either marked with H or L on the connected printer to indicate if the value is Higher or Lower than the pre-set Normal Range values. The display will in such a case show a * in front of the parameter value. The following flags are seen as Error flags or Warning flags Flag Cause Action Service call Comment TU Blockage in aperture Re-run sample If persist See TU (Time-out Upper Detector) on page 34. TL Blockage in aperture Re-run sample If persist See TL (Time-out Lower Detector) on page 34. SE Irregular count Re-run sample See SE (Statistical Error) on page 34. DE Interference between 2 populations FD Insufficient cell separation RBC/PLT OF HGB photometer offset out of range. LO HGB photometer lamp intensity too low HI HGB photometer lamp intensity too high Examine size distribution RBC/PLT or WBC Examine size distribution RBC/PLT Wait minutes and restart instrument. NG Negative HGB value Run Prime from menu 8.1 SE irregular HGB Re-run sample measurement TB Air bubbles in system Run Prime from menu 8.1 NM, OM, TM, BD RP WBC differential abnormality Red cells present in PLT concentrate (CA620-Cell- Guard only) If persist See DE (Distribution Error) on page 34. See FD (Floating Discriminator) on page 35. See OF (Offset error HGB) on page 35. See comment If persist See LO (Low blank level HGB) on page 35. See comment If persist See HI (High blank level HGB) on page 35. Examine sample by reference method Disregard PLT parameter result EC Blood control expired Use new blood control If persist If persists on all samples If persist See NG (Negative HGB) on page 35. See SE (Statistical error HGB) on page 36. See TB (Air bubbles) on page 36. See NM, OM, TM, BD (WBC Differential Flags) on page 36. See RP (Red Cells Present) on page 36. See EC (Expired control) on page en

34 Parameter Flags 4.1 TU (Time-out Upper Detector) The error flag TU might be displayed on the following parameters: RBC, PLT and/or WBC. This error is related to the counting time. It means that the counting time is outside the limits and displayed as HI or LO. Note: The instrument performs an auto-clean of the orifice after a TU is displayed; a re-analyze of the sample might cancel this warning in most cases. See Maintenance, Shut-Down & Transport on page 95. See also Trouble Shooting on page TL (Time-out Lower Detector) The error flag TL might be displayed on the following parameters: RBC, PLT and/or WBC. If the system is unable to move the liquid level in the metering unit up to the lower detector, this error is reported. No counting time is displayed in this case. Most probably this is caused by a clogged aperture (orifice). Note: That the orifice is cleaned automatically and that in most cases a re-analyze of the sample will cancel this clogging. See Maintenance, Shut-Down & Transport on page 95. See also Trouble Shooting on page SE (Statistical Error) The error flag SE might be displayed on RBC/PLT /WBC and/or HGB. During the analysing process, clumps of cells, partial blockages or other disturbances might affect the statistical accuracy of the displayed number of cells. Therefore the analyzer checks the count/time ratio continuously and if this number/time ratio is strongly fluctuating, the parameter will be flagged with the SE mark. 'SE' on the HGB parameter is related to an unstable extinction during the blank and/or sample measurement. Most probably the shown result will not be correct and the sample should be reanalyzed. See SE (Statistical error HGB) on page DE (Distribution Error) This warning flag is related to the floating upper discriminator of the PLT size distribution curve. The software analyzes the number of cells on the right-hand side of the position of the upper discriminator in respect to the total number within the size distribution curve. If a large population of cells is found in this area, it usually means that no correct minimum can be found between the RBC and PLT distribution. The reason for this might be an incorrect setting of the floating discriminator or an incorrect setting of a fixed discriminator as done in the Discriminator set-up in the set-up menu. However, on pathological samples with low PLT values this effect might occur even if the analysis is correct. The PLT values are probably correct within 20% of the actual value. In case of extremely low PLT values, this DE mark can be seen as a warning. In case of normal PLT values, it should be seen more as an error flag. A DE flag is also possible on the WBC parameter. In such case the size-distribution curve is too far shifted left, probably due to pathological sample. Another possibility is the presence of aggregated PLTs, which might interfere with the LYMF region. See Limitations on page en01

35 Parameter Flags 4.5 FD (Floating Discriminator) If the discriminator, between the upper volume of PLT and the lowest volume of RBC, has been set as floating (see set-up menu) the instrument tries to find a minimum on the PLT / RBC curve. At this point, the floating discriminator will be set. If no minimum can be found between the two limits that have been set in the discriminator set-up menu; the floating discriminator will locate itself on the limit where the lowest number of cells are found. This is a warning and NOT an error flag. On low PLT values, where often a non log-fitting PLT curve is found, this warning might occur frequently. Usually, with correct settings of the discriminator limits, the PLT parameter is still measured correctly. Important Let the analyzer warm up ca. 1-2 hours and proceed with the installation procedure. In case the OF flag persists, HGB values will be incorrect. Call your authorized service department. 4.6 OF (Offset error HGB) This error flag is related to the HGB parameter only. During a Power On or an exit from the Stand-by mode the offset voltage in the photometer system is measured. If the offset limits are violated, this flag is set. The OF flag might also occur during the installation process. In such case, the analyzer was probably exposed to high temperature changes and condensation may have occurred. 4.7 LO (Low blank level HGB) This error flag is related to the HGB parameter. During each sample a blank is measured as a reference, if the blank level is too low in intensity, due to a bad lamp or a contaminated cuvette, the automatic blank adjustment cannot work reliably. Go to the menu 6.2 an press digit [1]. The HGB photometer will now perform a self-adjustment. This process takes ca. 5 minutes. See HGB Value Flagged with LO on page HI (High blank level HGB) During each sample a blank is measured as a reference, however if the blank level is too high in intensity, due to a bad lamp or a previously cleaned cuvette, the automatic blank adjustment cannot work reliable. How to correct the HGB photometer See HGB Value Flagged with HI on page NG (Negative HGB) This error flag is related only to the HGB parameter. During each sample a blank is measured as a reference, however, if a sample has a lower absorption than the measured auto-blank; this error flag is set. The reason might be: a) Heavy fluctuations in stray light. b) Strongly coloured lyzer-reagent. c) No diluent or lyzer in the system or air bubbles. To cancel this error, perform a Prime from menu en

36 Parameter Flags 4.10 SE (Statistical error HGB) This error flag is related to a statistical check that is made on the HGB parameter. The blank and sample is measured 25 times and the SD is calculated from the photometer output values. If the SD exceeds a certain limit, the SE flag is displayed on the HGB parameter. The reason might be: a) Bad mixing in the WBC/HGB cuvette. b) Air bubbles or large particles in the cuvette. c) Heavy mains disturbance (contact your authorized distributor). In case this warning occurs occasionally, just re-analyze the sample TB (Air bubbles) This error flag is related to the start detector. If during the raise of the diluent column in the glass tube, an air bubble should pass the start detector; this warning is displayed. To cancel this error, perform a Prime from menu NM, OM, TM, BD (WBC Differential Flags) If no WBC Differential is displayed; the following warning flags are valid: NM'No Mode' No significant population was found. There is no valid 3 part WBC population. OM'One Mode' Only one population is found. This flag might be displayed in case of Granulocytosis or Lymphocytosis or if the Granulocytes are collapsed into the Lymphocytes (old blood). TM'Triple Mode' There are more than 2 main populations. This flag might be displayed in case of Monocytosis, heavy mains disturbance or wrong installation due to poor grounding of the instrument and/or connected printer. BD'Bad Distribution' The LYMF and GRAN population are too overlapped. This flag is displayed if the Granulocyte population is collapsed into the Lymphocyte area. The reason might be: Old blood or extremely fragile Granulocytes See Limitations on page RP (Red Cells Present) This flag is only displayed in case the CA620-CellGuard is used for PLT concentrates. If the concentration of Red Blood Cells is > 0.3 in the PLT concentrate, both RBC and PLT are flagged with 'RP' to indicate that Red Cells are present and that the PLT value may not be correct en01

37 Parameter Flags 4.14 EC (Expired control) This warning is displayed in case a Boule certified blood control is entered and the current date is more recent than the expiry date of the control. Note: The control must have been defined previously with the bar-code reader in menu Comments on Flagging Capabilities All anomalies and/or abnormal distributions signalled by the instrument should be verified manually for the presence of pathological elements. As a result of the differences in stability towards lyzing of cytoplasmic membranes in the different cell types, pathological elements can be found in a number of different zones. This also applies to the presence of normal or non-pathological cells that have been subject to chemotherapy or some other form of treatment. This might result in false flagging. See Limitations on page en

38 Parameter Flags en01

39 5 Installation Important The following procedures must be followed exactly. Boule has no responsibility in case of faulty or erroneous installation. Possible errors that may occur are: - Indication numbers - Erroneus parameter results - Excessive service needs Warning Electrical shock hazard Installation of external electrical equipment such as CVT must only be carried out by authorized service engineers. Violating this might result in injuries and/or loss of life and/or erroneous parameter results. Warning Electrical shock hazard The instrument must only be connected to a grounded mains supply. Violating this, might result in injuries and/or loss of life and/or erroneous parameter results. 5.1 Unpacking the Instrument The instrument is packed as standard in a especially designed protective box. Before the box is opened, check for any physical damages on the outside and notify your carrier immediately in case of such. Unpack the instrument and check that the following items are included: List of materials included in delivery Users Manual 1 Waste tube 1 Inlet tube with detector for Isotonic diluent. 1 Inlet tube with detector for hemolyzing reagent. 1 Mains cable 1 Check that the instrument and the accessories are not physically damaged. If there is any damage or accessories are missing, contact distributor and carrier immediately. Installation checklist (to be sent back to the return ). List of materials not included in standard delivery Printer and printer- or computer connection cable. Printer paper. Additional software for patient sample managing systems. Barcode reader. Reagents, blood controls, calibrators and cleaners. 5.2 Working Conditions Mains Supply Environment The instrument should be operated at an indoor location only. The instrument is designed to be safe for transient voltage as defined in IEC In case higher transient voltage, or mains voltage that exceed + 15% of the marking at the serial number plate are expected (e.g. within tropical areas), a CVT (Constant Voltage Transformer, also called Magnetic Stabilizer or Ferro-Resonant Transformer ) must be installed to protect the instrument against damage. Guidelines are given in the Service Manual section Installation auxilliary devices. Contact your authorized distributor in such a case. An abrupt interruption of the mains supply will not damage the instrument as all calibration constants and other parameters necessary for the correct working of the instrument are protected against mains supply loss. 1003en

40 Installation Location The instrument should be placed on a clean and level table or work station. Avoid exposure to sunlight. Make sure that the instrument has access to proper ventilation and that at least ca. 10 cm free space must be left at the rear of the analyser, marked as A in the picture below.. Place the instrument with easy access to the mains outlet and the mains cord. In case that emergency shut-down is needed, due to an obvious malfunction of the instrument and the instrument needs to be powered off follow the instructions below: 1. Switch off the instrument immediately by: Pulling out the mains cord from the mains supply. 2. Contact your authorized distributor s service department immediately. The instrument can work correctly within the stated temperature and humidity range however, to minimize the risk of bacterial growth in the reagent packages, it is strongly recommended to keep the laboratory at a temperature of approx. +22 C (72 F). ) Important Operating the instrument in an environment over +32 C (90 F) increases service-needs as well as degradation of sample specimen. A 1178.bmp Reagent packages Reagent packages are preferably placed at the same level as the instrument (e.g. the same table). In case such conditions cannot be met, place the Diluent container at the floor level (maximum1 meter below the instrument level) but keep the Lyzer container preferably at the same level as the instrument (e.g. the same table). Waste connection The instrument has an open waste outlet and can be connected to a central waste system within the laboratory. The waste outlet, or container, must always be at a lower level than the instrument. National and/or local regulations must be followed in all cases. Warning Contamination hazard Because no test method can offer complete assurance that HIV, Hepatitis B or C viruses, or other infectious agents are absent, the waste should be handled at the Biosafety Level 2 as recommended for any infectious human blood specimens in Protection of Laboratory Workers From Infectious Disease Transmitted by Blood, Body Fluids and Tissues- 2nd Edition, Tentative Guidelines (1991) Document M29-T2 promulgated by the National Committee for Clinical Lab. Standards in the U.S.A. (NCCLS) en01

41 Installation 5.3 Mechanical Check and Set-Up Recommendation Installation of the instrument should be carried out by the authorized distributor. Instrument installation 1. Lift the instrument and place it on the chosen location as shown below. Be careful not to stress the front door of the instrument tif 2. Open the front door of the instrument. 3. Locate the cover plate of the tubing system tif 4. Unlock the screw at the left hand-side as shown below. 5. Lift up the screen slightly and remove it forwards. 1003en

42 Installation 6. Remove the grounding wire at the rear of the cover plate tif 7. Remove all transport guides at the pinch valves. These guides are red coloured plastic clamps inserted in each valve. Save them for later use in case of a re-installation. Transport guides 1026.tif 8. Re-assemble the front cover in reverse order. Be sure to reconnect the ground-wire! Reagent pack installation 1. Place the reagent pack in the proper place. See Reagent packages on page Put the probes as shown below (the example shows the lyzer container). Important One valve is located behind the pre-dilute start lever MPA. Do not forget to remove the transport guides in this valve. The instrument will not operate correctly in case a transport guide is not removed. Possible consequences of not removing all transport guides are: Indication numbers, incorrect parameter results and/ or incorrect counting times bmp en01

43 Installation 3. Locate the reagent inlets at the rear of the instrument, see picture below tif 4. Connect the corresponding tubes from the reagent probes and the level detector cables as shown in the picture below. Caution Bio hazard The end of the waste tube must be at a lower level than the instrument itself. Not following this might lead to improper instrument functions and/or waste liquid flowing backwards into the instrument. 5. Connect the waste outlet to a proper container or open drain. See Waste connection on page tif Final set-up 1. Locate the serial number plate at the rear and check that the mains voltage and frequency corresponds to your local mains supply outlet. 2. Insert the power cable and connect to the mains supply. A short beep is heard where after the instrument will perform a self-check that normally takes 2 minutes. (Maximum15 minutes in case of condensation). 1003en

44 Installation Printer installation (optional) In case the DPU411-type II/DPU414 printer is used as supplied through Boule, connect the printer to the print outlet as shown below tif Follow the instructions as shown in the DPU411-type II/DPU414 user manual how to insert paper and how to set the printer 'on-line' In case an IBM compatible printer Epson or HP printer is used, please refer to Printer and Serial Output on page Front Panel and Command Keys The front panel of the instrument consists of: 1. Numerical keyboard 2. Display 3. [Print] 4. [Menu] button 5. Arrow keys, tif en01

45 Installation Using the keyboard Numerical keys are used to enter ID, calibration factors, normal ranges and other entries that need numerical identification. [CE] always clears a previous entry unless the [Enter] validation key has been pressed tif [Print] will send the sample data to either the printer and/or serial output, depending on how the instrument is configured by the end-user. [Menu-Operate] is used to switch between Menus and the operational mode. The operational mode is defined as the instrument status where the next sample can be entered at the aspiration pipette tif The arrow keys are used to scroll through the Menu system, switch between different display modes and to display alternative parameters. The right arrow key is also used to enter either a + or a - within the calibration menu tif Note that the [Power-On] indicator is an indicator only and no key! tif 1003en

46 Installation Note: Aspiration command keys are not located on the keyboard. Aspiration of a sample is started by pressing the start-lever behind the aspiration needle. 5.5 Filling the system with reagents After power-on, the instrument will perform a self-check which lasts for ca. 2 minutes. During this period, no key entry is accepted by the instrument. 1. Press [Menu]until the main menu is displayed on the LCD screen. 2. Scroll with the up-arrow key to 8 and press [Enter]. 3. Scroll to 8.2 and press [Enter]. 1036en.gif 1037en.gif The system is now filled with reagents. This cycle lasts for ca. 6 minutes. When the system is finished with this cycle, the cursor field returns to the field 8.2. Press [Menu] to return to the main menu en01

47 6 Initial System Configuration 6.1 CA620-CellGuard The CA620-CellGuard is configured as default in blood mode, in other words; as a pre-donor screening instrument. The end-user however, must decide if the CA620-CellGuard is used for pre-donor screening or if it is mainly used to monitor PLT concentrates. Default settings of the instrument can be printed out after the installation procedure by selecting menu Setting up the CA620-CellGuard for Pre-Donor Screening The CA620-CellGuard used for pre-donor screening accepts whole blood at the open aspiration pipette, micro capillary collected blood through the MPA device or pre-diluted blood entered at the pre dilute aspiration probe. In case the optional cap-piercing device is installed, closed tubes can be entered as well. Normal range values, floating discriminator settings are set as default to the most common and correct settings. All available parameters are set as default to be reported on the LCD screen as well as on the connected printer. Hence, no extra settings are needed except that the instrument is programmed to default in 'blood mode' To do so: Press [Menu] until the main menu is displayed. 4. Scroll with the up-down arrow keys to line 5 [Set up]. 5. Press [Enter]. 6. Scroll to line Press [Enter] 8. Press digit [1] 9. Press [Enter]. This sets the CA620-CellGuard to blood operational mode as default and the configuration is identical to the CA en.gif 1039en.gif 1004en

48 Initial System Configuration 6.3 Setting up the CA620-CellGuard for PLT Concentrate The CA620-CellGuard used as a monitor for PLT concentrates, accepts the sample at the open aspiration pipette. Normal range values andl floating discriminator settings are as default the most common and correct settings. Parameters that are not valid are as default blocked from the display (e.g. HGB and related parameters are not displayed and printed). Hence, no extra settings are needed except that the instrument must be programmed as default in 'PLT concentrate mode'. To do so: 1. Press [Menu] until the main menu is displayed. 2. Scroll with the up-down arrow keys to line Press [Enter] 4. Scroll to line Press [Enter] 6. Press digit [2] 7. Press [Enter] This sets the CA620-CellGuard to PLT concentrate operational mode as default. 1038en.gif 1041en.gif 6.4 CA620/530 The CA620/530 is configured as default to the most common use. This applies to Normal Ranges, Floating Discriminator Settings and Units. Default settings of the instrument can be printed out after the installation procedure by selecting menu 5.9. Menu 5.8 is set to 1 as shown in Setting up the CA620-CellGuard for Pre- Donor Screening on page en01

49 Initial System Configuration 6.5 Setting Date and Time 1. Press [Menu] until the main menu is displayed and select menu Scroll to line Press [Enter] 1042en.gif 1043en.gif As seen on the LCD screen, 4 different date formats can be set. For EU, set date format 0, for the U.S. set date format Use the up-down arrow keys to scroll to the date format field. 2. Enter the correct setting. 3. Scroll to the line Date' and enter the correct date using the previous set date format. 4. Scroll to the line Time and set the correct time in 24 hours notation. In case a different date separator is required: 1. Scroll to the line Date separator. 2. Press [Enter] From the following menu, different date separator signs can be chosen. 3. Use the scroll arrow keys to select. 4. Press [Enter] to validate. 1044en.gif 6.6 Printer Configuration In case a printer is connected to the instrument, which is strongly recommended, the print command as well as the print format needs to be set. 1. Press [Menu] until the main menu is displayed. See below. 1045en.gif Point 2, 3 and 4 describes the settings of the print commands and format. 1004en

50 Initial System Configuration Make sure that the printer is connected and put on-line. 2. Scroll to line Press [Print] A list is printed with several options. In case an automatic printout after each sample is required including the size histograms: 4. Select 2 5. Press [Enter] Setting 0 will disable the auto-print of the instrument. 6. Scroll to line 3. This entry selects what and where to print the parameter results if the [Print] key is pressed. 7. Press [Print] again, an equal list is printed. 8. Select 2 9. Press [Enter] to activate the [Print] key function to print all parameters including the histograms. 10. Scroll to line Press [Print] A list is printed with available pre-programmed formats. In case a DPU411-type II/DPU414 printer is connected (recommended) only formats can be chosen which are indicated as 'DPU411'. The print format function describes the order of parameters on the printout as well as the font style. As default, format 8 is set (DPU). 1046en.gif Note: If no external computer is connected to the instrument, do not select settings 3-8 on the Main Menu. For detailed information regarding printers and printing options, please refer to section Printer setup menu CA620 on page 73 and Printer and Serial Output on page 93. For advanced printer options, refer to appendix available from your distributor (in English only) en01

51 Initial System Configuration 6.7 Select Language The instrument can be programmed to show the displayed text in different languages, e.g. English, German, Spanish etc. (depending on program version). To change language: 1. Scroll to Setup menu from the main menu. 2. Press [Enter] 3. Scroll (up) to Setup menu2. 4. Press [Enter]. 5. Type the number corresponding to the selected language 6. Press [Enter] to validate to new setting. (e.g. # 1 = English) 1047en.gif 6.8 Select Units The instrument has six different unit modes, based on SI- and CGS units. To change, choose: 1. Select menu Choose the required unit expression from the table below. 1048en.gif 1004en

52 Initial System Configuration Select number: HGB expr g/dl mmol/l g/l g/l g/dl g/dl HCT expr. % l/l % l/l % % WBC 10 3 /mm /l 10 9 /l 10 9 /l 10 3 /µl 10 9 /l RBC 10 6 /mm /l /l /l 10 6 /µl /l HGB g/dl mmol/l g/l g/l g/dl g/dl HCT % l/l % l/l % % MCV µm 3 fl fl fl fl fl MCH pg fmol pg pg pg pg MCHC g/dl mmol/l g/l g/l g/dl g/dl PLT 10 3 /mm /l 10 9 /l 10 9 /l 10 3 /µl 10 9 /l MPV µm 3 fl fl fl fl fl RDW(CV) % % % % % % RDWa fl fl fl fl fl fl PDW fl fl fl fl fl fl PCT % % % % % % LPCR % % % % % % LYMF 10 3 /mm /l 10 9 /l 10 9 /l 10 3 /µl 10 9 /l GRAN 10 3 /mm /l 10 9 /l 10 9 /l 10 3 /µl 10 9 /l MID 10 3 /mm /l 10 9 /l 10 9 /l 10 3 /µl 10 9 /l LYMF% % % % % % % GRAN% % % % % % % MID% % % % % % % en01

53 7 Routine Operation The instrument should always be connected to the mains supply and will automatically perform an auto-checking/cleaning cycle every fourth hour. This unique feature protects the instrument from bacterial growth, checks electronic and mechanical settings automatically and eliminates virtually all user maintenance. If the instrument is not used within 45 minutes (no key has been pressed or no sample has been run), the instrument will automatically enter a Stand-by-mode 1. Press [Menu] and the instrument is operational after the auto prime cycle is finished. 2. Press [Menu] again to enter the operational mode and the last run sample will be displayed. See pictures below. In case the instrument was powered-on and menu 8.1 or 8.2 was chosen, the sample screen will display no parameter results. 1049en.gif 1050en.gif 1051en.gif Applicable for CA620-CellGuard The operation is identical if the system is programmed for pre-donor screening or used as a PLT concentrate control, however, the displayed number of parameters will be different if used in PLT concentrate mode. 7.1 Background Check The following sequence is performed to check that the background is low enough, before each series of counts: Use isotonic diluent as the sample and aspirate by pressing the whole blood start lever which is located behind the whole blood aspiration needle. Note that the aspiration time of diluent will be ca. 10 seconds in case the CA620/530 is set up for normal use on blood specimen. The CA620/530 applies a blood detector, which is an optical device that stops the blood flow when blood is detected after the shear valve system. Therefore, running in blood mode and entering diluent as a sample, the system will time-out after ca. 10 seconds and continue its cycle. 1005en

54 Routine Operation The background should not be higher than the figures below, assuming that at least 2 blanks are run after a sample. ( CGS units) ( Units =1 : RBC 0.01 WBC 0.1 HGB 0.1 PLT en.gif 7.2 Analysing the Sample (Open Tube) Choose the operational mode with [Menu-Operate] so that the last run sample is displayed. Aspirate the sample through the aspirating pipette by pressing the start lever behind the aspiration needle. See picture below. The display shows the following sequences: Last Sample (= blank) Aspirating sequence 1053.bmp Warning Contamination hazard if contaminated blood enters into open cut. Always wear protective gloves when handling blood samples. (Gloves in the picture are not shown for clarity reasons only.) 1052en.gif 1055en.gif en01

55 Routine Operation The instrument switches now to the following menu. Important Remove the sample from the open inlet aspiration needle when the display has changed from Aspirating to Counting cycle in progress. Not removing the sample could result in incorrect washing sequence of the aspiration needle. 1056en.gif Although not mandatory, enter the ID of the sample with the numerical keys. Note that a positive identification of a sample is highly recommended to avoid erroneous patient parameter reporting. A maximum of 15 digits are allowed in the ID field. In case the optional Bar-Code reader is installed, simply scan in the ID barcode from the sample tube. After approx. 30 seconds; the CA620 will switch to the INTRA mode as shown below: 1057en.gif Note: The INTRA mode is only available on the CA620-series The display shows the counting rate on each counted parameter in real-time. The horizontal lines in the boxes represent the parameter normal range as set for PROG1 in menu 5.4.1, which is assigned to 'blood mode'. The drawn line during the analysis is slightly irregular due to the counting statistics. However if the drawn line is within the parameter limit lines, the sample is probably within the normal range. In case the drawn line is outside the limits, the sample is probably pathological. With this tool, the operator is alerted of a suspected pathological case before the sample is analyzed completely. The vertical dotted lines represent the expected normal counting time. See below. Upper normal range setting Rate Lower normal range setting 1058.gif 1005en

56 Routine Operation Sample displayed after ca. 53 seconds from aspiration: 1059en.gif 7.3 Analyzing the Sample (Pre-Dilute) Any dilution rate between 1:200 and 1:250 can be used under the condition that the minimum total volume is 5ml and the maximum volume 8 ml. It is obvious that always the same dilution rate must be chosen as any reproducibility error in an external dilution will directly affect the counted parameters. Important The instrument is ready to accept the next sample after the flashing display cursor in the upper left display corner disappears. Entering the next sample before the flashing cursor disappears will result in erroneus parameter results for the next sample. Examples: 20 µl and 5 ml diluent, 30 µl and 6 ml diluent or 40 µl and 8 ml diluent The sample should be analyzed as soon as possible. Prolonged waiting increases the inaccuracy of the MCV and WBC differential parameters. Place the cup with the pre-diluted sample under the aspiration pipette for pre-diluted samples and press the lever behind the pre-dilute aspiration pipette. Note that the instrument aspirates more than 5 ml. Volumes over 5ml are not specified. This means that in most cases the whole sample (volume) is aspirated into the analyzer. Remove the sample cup after aspiration. The display sequence on the LCD screen is identical to the description in Routine Operation on page 53 above. If no sample was entered and the pre-dilute start lever was pressed anyhow, the system will recognise this and restore the liquid flow system automatically. 1060en.gif en01

57 Routine Operation 7.4 Analysing the Sample (Micro Pipette Adapter, MPA) The Micro Pipette Adapter (MPA) is a device that allows the operator to use direct capillary samples without any pre-dilution. This is suitable in case the patient is nearby the instrument, like small care-stations or private doctor's offices and especially when used as a pre-donor screening device at blood banks. Capillary tubes used are high precision 20 µl (+/- 1%) EDTA tubes supplied by Boule. 1. Press [Menu] so that the instrument is in operational mode. (The previous sample is displayed). 2. Pull out the MPA adapter, remove the previous sample capillary pipette and place the adapter on the table in the supplied MPA holder. The display shows: Warning Contamination hazard if contaminated blood enters into open cut. Always wear protective gloves when handling blood samples. (Gloves in the picture are not shown for clarity reasons only). 3. Puncture, using the Boule Micro Lancet. 1061en.gif 1062.jpg 4. Aspirate the sample as shown below. Caution Always insert the capillary tube in the longest metal tube of the MPA. Inserting the capillary tube in the shortest metal tube of the MPA might damage the MPA or break the capillary jpg 5. Insert the micro pipette (capillary) in the longest tube of the MPA device jpg 1005en

58 Routine Operation 6. Insert the MPA into its holder and the instrument will automatically start the analyzing sequence jpg Note: 7. Detailed movie shots are available on Boule s support server how to use the MPA system in detail. Please put your browser to the following address and download the MPEG movie shots. The movie shot shows also how to clean the Micro Pipette before it is loaded into the MPA Analysing the Sample (Cap Piercing Device) The cap piercing device model 220 is an optional built-in unit that enables the instrument to be used with several types of closed tubes. A tube selector is used with 6 positions giving the operator the ability to use 6 different kinds of tubes. A motor driven needle is penetrating the closed tube and aspirating the sample after which the needle and aspiration tube is cleaned and dried. The closed tube might be of a vacuum or zero pressure type. The adapter handles even a slight over pressure in the closed tube in a correct way. The minimum volume in the closed tube should be ca. 1 ml using a standard B&D tube with a length of ca. 73 mm. 1. Rotate the wheel to a position that fits the dimension of the tubes you are using. The positions can hold auxiliary adapter devices that can be ordered from Boule to fit your local needs. Important Fill the micro pipette completely and wipe off the excessive blood on the outside surface. Ignoring this instruction might cause incorrect and non-reproducable results. Important Maximum length of tube 77 mm. Lengths exceeding this dimension will not fit into the adapter. Use only tubes with a maximum length of 77 mm 1066.bmp Warning Contamination hazard if contaminated blood enters into open cut. Always wear protective gloves when handling blood samples (Gloves in these pictures are not shown for clarity reasons only.) en01

59 Routine Operation 2. Push (rotate) the protection cover to the left and insert the tube up-side down. Caution Insert the sample tube with lid facing downwards. Ignoring this instruction may damage the aspiration needle bmp Caution Avoid using the same tube more than twice in the cap piercing device. Not doing so might increase the risk that rubber particles from the lid clogs the instrument which leads to incorrect results and/or excessive service. 3. Push (rotate) the protection cover to the right bmp The aspiration cycle is now started following the sequence as described in Analysing the Sample (Open Tube) on page 54. Remove the tube after the sample parameters are displayed in reversed order. The adapter is ready to accept the next tube when the sample parameters are displayed and the flashing cursor in the parameter-field of the display disappears. 1005en

60 Routine Operation 7.6 Advanced User Options (CA620-CellGuard) In section Routine Operation on page 53, the normal use of the instrument is described. The system was either used for Blood mode or PLT concentrate mode. It is possible however to switch between these 2 modes without altering menu 5.8. Suppose the following: In case the CA620-CellGuard was set up for PLT concentrate mode as default but it is required to analyze some whole blood samples. Proceed as follows. 1. Press the up/down -keys until PROG 1 is displayed within the Operational mode Note that the text PROG1 might have been replaced with the text Blood. See Set PROG names on page 71. The LCD display shows the following. 1069en.gif 2. Aspirate the sample by pressing the start lever or pull out the MPA. 3. After the aspiration of the sample or insertion of the MPA, enter the sample ID if required. The sample is now processed as Blood and all PROG 1 settings are applied to this sample. Note: The next sample will fall back to the default PROG mode unless again changed by the user en01

61 8 User Interface This section describes the function of each available menu in the instrument that is not described in any other section of this manual. The service menu is described in the service manual and is available in English only to your authorized distributor. The main menu is used to directly select the most commonly used functions. Direct access to the Sample memory, as well as easy access to the System flow menu, is provided. 1071en.gif 8.1 Sample Memory Entering position 1 from the main-menu gives access to the sample memory. View, print Statistical calculations and delete functions are selected by ID#, SEQ #, Date or PROG in any combination. In case the memory is full, the oldest sample is automatically deleted. As default, the current date is used, giving direct access to all samples during the current day. 1072en.gif In the display example above it is seen that a total of 19 samples are in memory but none (0) during the current date. The whole memory, in this example 19 samples, is selected by just pressing [Enter] at the From Date line in menu en.gif Use the arrow down key to select other condition-selections. The selected number of samples is always displayed as well as the total number in memory. Press [Menu] to return to the previous menu 1.4 to 1.8. Please find below some examples how the sample memory can be used. 1006en

62 User Interface Question 1 (example): To-days date is 20 July We have a sample in memory tagged as ID = This sample was analyzed 9 times during this day. We want to determine the CV of this sample. Answer: 1. Enter the Sample Memory. 2. Scroll to ID = 3. Type Press [Enter] Now, the display shows SEL 9 of 75, confirming that 9 samples with this ID were found in memory of total 75 samples. 5. Scroll down to Statistical Calculations. 6. Press [Enter] 7. Press [Print] if a printout is required. Note: Statistical calculations are done on both Normal+Abnormal and Normal parameter values only. Abnormal parameter values are defined as being all values except 0 or out of measuring range. Normal parameter values are values within the parameter normal range as set in menu 5.4. SD, CV, X and n are displayed for each parameter. Use the left/right - keys to scroll between the parameters and use the up/ down -keys to select SD, CV, X or n for NORM+ABN or NORM values only. Pressing [Print] will print all available data to the selected printer. This is the recommended way of listing the statistical calculations. Below is an example of a Statistical calculations display with no specific ID selection: 1074en.gif 1075en.gif The example above shows that on RBC, 16 samples are present in the selected memory whereof 9 within the normal range. Question 2 (example) We want to have access to all samples in memory and scroll backwards through all samples en01

63 User Interface Answer: 1. Enter the Sample Memory menu Scroll down to line 1.4 and press [Enter]. 3. Scroll to line From Date= and press [Enter]. Now, the bottom line will change to 198 OF 198, confirming that all samples in memory are selected. (the number 198 is an example only). 4. Press [Menu] to return the menu 1 5. Scroll to line 1.5 and press [Enter]. The display shows now the last sample in memory. 1. Use the up/down keys to scroll through the sample memory. 2. Use the right/left keys to display different parameters. The [Print] key can be used to print a specific sample. 1076en.gif The letter 'M' is displayed in the upper right corner to indicate that the display shows a sample in memory and not the last run. Question 3 (example) CA620-CellGuard We want to check the mean value of all PLT concentrate samples in memory. Answer: Enter the Sample Memory from the main menu Scroll down to line 1.4 and press [Enter]. 2. Scroll to the line From Date= and press [Enter]. 3. Scroll down with the up/down key to the line PROG and select 2. As 2 is assigned to PLT concentrate mode. The display might change to 22 OF 200 confirming that 22 samples were tested in PLT concentrate mode. 4. Press [Menu]to return to the sample memory menus. 5. Scroll down to Q/C calculations and press [Enter]. 6. Press [Print] to get a print out of the statistics. 1006en

64 User Interface 8.2 Setup Menu Within the setup menus all user settings are defined, calibration, normal range settings etc. Scroll to line 5 in the main menu and press [Enter]. Scroll with the up/down keys to display the second page of the set-up menu. 1077en.gif 1078en.gif Set parameter normal ranges In this menu the normal range for each parameter can be defined. Parameter values outside these limits are marked with '*' on the LCD display and H (high) or L (low) on the printout. Normal ranges for each parameter might vary considerably between populations and should be established using local population mean values. The default values are set according to medium values within the EU and US and can be listed on the connected printer by choosing menu 5.9. The instrument has the possibility to set 9 different normal range settings assigned to PROG1-9. Within the CA620/530, PROG 1 is assigned to 'human blood mode' and PROG 8 is assigned to blood controls. PROG 3 to 9 (except 8) are not assigned to any particular application but could be used to set Normal ranges, for example male/ female or children. Scroll with the arrow keys to menu 5.4 and press Enter. The following is displayed. 1081en.gif 1082en.gif Enter the required ranges by using the numerical key pad. 1. Validate with [Enter]. 2. Scroll through this menu using the arrow keys. 3. Press [Menu] to return. Note: Each PROG has its own set of Normal Range settings, Floating PLT/RBC discriminator settings and WBC differential settings. The Calibration is the same for all PROGs en01

65 User Interface CA620-CellGuard 1. Enter PROG 1 to set normal ranges for Blood mode as shown above. or 2. Enter PROG 2 to set normal ranges for PLT concentrate mode. The following example sets the normal range limits for PLT concentrate mode. 1083en.gif 1084en.gif Note that several parameters do not have normal ranges set as they are blocked from being displayed and printed. See also menu 'Block parameters'. Enter the required ranges by using the numerical key pad. 3. Validate with [Enter]. 4. Scroll through this menu using the arrow keys. 5. Press [Menu] to return. Set floating discr. PLT/RBC Scroll with the arrow keys to menu 5.6 and press [Enter]. In this menu the floating range for the discriminator (also called threshold) is set for each PROG. It is not advisable to alter the PROGs default settings. The default is set to values that are strongly recommended. Blood mode In the example below, PROG 1 is shown by pressing [Enter] and the settings for the floating discriminator are displayed. 1085en.gif 1086en.gif The displayed fields are: a) PLT-L. The lowest possible setting for the floating threshold between PLT and RBC in fl (= µm 3 ). As default this is set to 15 fl. b) PLT-H. The highest possible setting for the floating threshold between PLT and RBC in fl (=µm 3 ). As default this value is set to 30 fl, which is the maximum level available in this menu. Note: Applicable for CA620-CellGuard 1006en

66 User Interface c) PLT conc. mode is set to 0 as PROG 1 is assigned to Blood mode only. PLT concentrate mode The example below shows the default values set for PROG 2, which is assigned to PLT concentrate mode. 1083en.gif 1088en.gif The displayed fields are: a) PLT-L. The lowest possible setting for the floating threshold between PLT and RBC in fl (=µm 3 ). As default this is set to 15 fl b) PLT-H. The highest possible setting for the floating threshold between PLT and RBC in fl (=µm 3 ). As default this value is set to 60 fl, which is the maximum level available in this menu. c) PLT conc. Mode is set to 1 as PROG 2 is assigned to PLT concentrate mode only. Setting this menu to 1 enables the PLT-H setting to a maximum level of 60 fl. This setting (60fl) is chosen as default in PLT concentrate mode to include possible macro PLTs in the total PLT count. This setting 1 also enables the aspiration mode to switch to a time aspiration instead of using the Blood detector. Also, if PLT-H is set to 30 fl instead of 60 fl, all PLTs larger than 30 fl will be reported by the system as RBCs, which might introduce a slightly false RBC parameter value. Therefore, it is recommended not to change this setting without a compelling reason. Important Do not alter PLT conc. mode. This must be 1 to enable the correct sample aspiration mode. Setting PLT conc. mode to 0 will aspirate the sample for 10 seconds and macro Platelets up to 60fl will not be counted. Set discr. WBC Scroll with the arrow keys to menu 5.6 and press [Enter]. In this menu the total range is set in fl, for which the mathematics are applied to check for a valid LYMF and GRAN population within the 3 part differential. The settings in all PROGs are the same and set as default to fl. Hence, the software will look for a valid population where 2 main modes (peaks in the histogram) is found within this volume range. It is not recommended to alter these settings without written instructions from Boule. The following is displayed. 1089en.gif 1090en.gif en01

67 User Interface The displayed fields are: a) LYM-L. The lowest possible mode (peak on the histogram) where Lymphocytes might be detected. b) GRAN-H. The highest possible mode (peak on the histogram) where Granulocytes might be detected. In case any of the modes (peaks on the histogram) are outside these limits, the 3- part differential is aborted and a NM or OM differential flag is displayed. See further Parameter Flags on page 33. Set default discr. program CA620/530 This menu sets the default mode of the instrument, which PROG setting is used whenever a sample is aspirated. Setting menu 5.8 to 1 will select all PROG 1 settings, which equals Blood mode as default with any aspiration of a sample. Setting menu 5.8 to 2 will select all PROG 2 settings, as default with any aspiration of a sample. 1091en.gif Print all settings 1. Scroll with the up-down arrow key to menu press [Enter]. The connected printer will list all settings that are user programmable. It is advisable to do so after the installation procedure is finished to backup and save the original settings of the instrument. Detailed information of each printed value is listed in the CA620/CA530 Service Manual. The printed list is listed in the English language only to simplify service, maintenance and failure reporting to the manufacturer. 1092en.gif 1006en

68 User Interface 8.3 Setup Menu 2 1. Scroll with the up-down arrow key to Setup menu 2 (menu 5.10). 2. press [Enter]. The following is displayed. 1093en.gif Within setup menu 2, less common functions are displayed and altered, such as language, units etc. To set language and units; please refer to Initial System Configuration on page 47. Machine ID Refer to Setup Menu 2 on page 68 above and scroll down with the arrow keys to the line Machine ID. This menu is only of use in case the instrument is connected to a computer system. On the serial output a Machine ID number is sent to the connected computer to identify the instrument in case that several Boule analyzers are used in a lab. In such an environment the Machine ID can be set to the serial number of the instrument to give the host a positive identification from which system data was sent. Blood detector setup. Refer to Setup Menu 2 on page 68 above and scroll down with the up/down arrow keys to the line Blood det. Norm, see below. 1094en.gif 1095en.gif The CA620/530 aspiration of samples in Open tubes and Cap piercing is stopped when the sample (blood) reaches a blood detector, which is located after the shear valve system. This blood detector consists of a (green) LED and a photocell. Within 10 seconds after the aspiration command, this device should detect blood. In case no blood is detected, the system will proceed anyhow. Setting this menu to 0 will enable the blood detector function of the CA620/530. This means that if the instrument is used in Blood mode, the setting must be 0 at this line en01

69 User Interface Applicable for CA620 CellGuard Scroll down with the arrow key to menu line In this menu line Blood det. PLT-C the aspiration time is set in seconds. As the Blood detector cannot detect PLT concentrate, this function is disabled and the aspiration of the sample is based on a time set in this menu. To check that this time is correct, observe the flow of the PLT-concentrate during the sample aspiration. The aspiration should stop when the PLT concentrate has passed the blood detector with at least 3 cm. If not, adjust the setting accordingly. An aspiration time of 1.5 seconds is set as default as seen above. Hence; the text 0=ON means that the blood detector is enabled. If set to a value > 0, the aspiration timer is enabled and the display shows the aspiration time in seconds. Serial port setup In case the instrument is connected to an external computer, the serial data flow has to be set. Scroll to this menu line with the arrow keys and press [Enter]. The following is displayed. 1096en.gif Change the setting, if required, by using the left/right arrow keys and jump to another line within this menu with the up/down arrow keys. See further in section Printer and Serial Output on page 93. Barcode reader In case a Barcode reader is connected (available from Boule as optional device), the device must be enabled in this menu. 1097en.gif Scroll with the up/down arrow keys to line If no Barcode reader is connected, this line must read 0. The available Barcode reader from Boule is enabled by setting this line to 2. In case the ISBT code is used as standard in blood banks, select 4 instead. This will cancel all leading = and & signs. 1006en

70 User Interface PLT offs and High altitude comp In menu the PLT background can be set. This entered value is subtracted from all PLT readings. This menu should be handled with care and only used if the diluent background on PLT is stable and not higher than 10. The menu is used whenever the instrument is installed at levels higher than 1500 meter (4500 feet) above MSL (Medium Sea Level). 1098en.gif Scroll down to this line using the arrow keys and set '1' in case the instrument is located above 1500 meters (4500 feet) MSL. This setting will only extend some of the washing sequences in the instrument due to the capacity reduction of the waste (drain) pump when used at high altitudes. No other instrument specifications will be affected. Print control blood id:s 1000en.gif This menu prints out a list of defined quality control-blood types. Type [Enter] at this menu line to print out the list. As quality control-blood is not comparable with human blood regarding the structure of the WBC differential mainly, certain discrepancies in the total WBC count and/or differential count might occur whenever using such fixed cells as a normal sample. Entering the defined ID numbers as obtained from the list, terminated with a + sign (right arrow key), will instruct the instrument to shift it's discriminator range automatically so that it fits the specific control-blood see also section Calibration and controls on page 81, in this manual. Example of a printout: 777+ Boule Low 888+ Boule Norm 999+ Boule High Thus; entering one of the above defined control-blood Product-numbers as ID#, will be shown on the display (only) in clear text as a confirmation that the controlblood mode was selected. E.g.: 888+ will display Boule Norm., but is stored in memory as en01

71 User Interface Hence, enter such control blood by typing 888 and press the right arrow key. Note: Entering a specific control blood Using 777+ to 999+ Boule control bloods, are stored as default in PROG 8. Reagent type This menu line is only used to initialise the basic set up at the factory. It defines for which purpose the instrument is used and stores the correct default values. This menu is password protected and cannot be altered by the user. It should show 15 for the CA620-CellGuard and 11 for the CA620/530, in all cases. CA620-CellGuard CA620/ en.gif 1014en.gif Set PROG names As described in previous sections, the instrument is equipped with 9 preset- table programs which are linked to Floating discr. RBC/PLT, Set parameter normal range and WBC discr. Program. Assigning the PROG numbers to a name, that is shown on the display as well the printout at each sample, will simplify the identification of in which mode the sample was run. Example on how to assign a name to a PROG # The CA620-CellGuard has 2 defined programs PROG1 and PROG2. PROG1 is assigned to Blood and PROG 2 is assigned to PLT concentrate. Therefore, it is advisable to set the name for PROG1 to Blood and the name for PROG 2 to PLT-C. To do so, 1. Scroll down with the arrow keys to the line Set PROG names. 2. Press [Enter] The following is displayed: 1101en.gif 1102en.gif In the above example, we want to set the name Blood for PROG1. Press [Enter] and the sub menu is displayed asking to define the text to be shown on the display and printer. 1006en

72 User Interface Press [Enter] to set the required text on the display or scroll to the next line to alter the printed name on the printout instead. The following is displayed. 1103en.gif 1. Scroll with the up/down arrow keys through the displayed field. 2. Press any digit to select the required character. 3. Press [Enter] to return. Changing both PROG1 and PROG2; the list will now show: CA620-CellGuard CA620/ en.gif 1146en.gif Note That the PROG names are not changed in any menu to Blood or PLT-C but clarified only as shown above. The display and printout however will show Blood or PLT-C instead of PROG1 or PROG2. Block parameters The CA620 allows the operator to block certain parameters to be displayed and printed. This is especially useful when the instrument is used for PLT concentrate control only. Several parameters are of no interest in such case, like HGB, HCT, MCHC etc. To do so: 1. Scroll with the arrow keys to line Block parameters. 2. Press [Enter] en01

73 User Interface The following is displayed. 1105en.gif 1. Scroll down to the line PROG 2 in case some of the parameters in the PLT concentrate mode should be blocked. See below. 2. Press [Enter] and the next sub menu is displayed. 1106en.gif 1107en.gif In this menu, setting a 1 to a parameter means that it will be displayed and printed. Setting 0, will block the parameter from the display and printout. In the above example it is seen that all parameters are blocked except RBC, PLT, MPV, WBC and LPCR whenever the CA620-CellGuard is used in PLT concentrate mode. Printer setup menu CA620 This menu is used for advanced printer options and user definable printout programming. 1108en.gif Detailed information is available in appendix Please contact your local distributor in case special printer functions are required. This appendix is available in the English language only and requires basic knowledge about printing protocol, formats, font setups etc. Block pre-dilute start This menu is used to delay the pre-dilute start switch with 5 seconds. Set '1' to enable this function. To minimize the risk that a user enters whole blood at the pre-dilute inlet, this mode might be enabled. 1006en

74 User Interface In such a case, one must keep the pre-dilute start lever pressed for 5 seconds to start the pre-dilute aspiration. 1109en.gif Service menus Service menus, starting at line 6 of the main menu, are used by your authorized distributor to check and maintain the instrument. These menus are described in the Service Manuals available to your authorized distributor on CD-ROM. Several of these menus are password protected. For clarity reasons and back reporting to the manufacturer, service menus and the proper description of each is available in the English language only en01

75 9 Warning Displays Warnings are displayed in clear text in case of any abnormal situation.this section shows the available texts if not mentioned in other sections of this manual. This section lists all available warning texts. 9.1 Warnings Related to the MPA and Pre-Dilute Inlet 1110en.gif This is a normal warning and indicates that the MPA was pulled out. The instrument is waiting for the MPA to be inserted where after a count cycle starts automatically. 1111en.gif The MPA cycle was aborted by pressing the [CE] key. Push back the MPA. The system will not start a count cycle. 1112en.gif 1113en.gif The MPA was pulled out before the cycle was finished. Push back the MPA adapter and the instrument will restore the flow system with a prime cycle. See menu message above. 1114en.gif 1008en

76 Warning Displays The MPA was pulled out in a wrong mode (a menu was displayed). The MPA may only be pulled out in Operational mode where the last run sample is displayed. The operational mode is selected by pressing the [Menu/Operate] key. 1115en.gif The above warning indicates that the Pre dilute Sample inlet was activated but no sample was aspirated. This might be caused by: a) No sample is entered. b) An attempt is made to run on distilled water in the pre-dilute inlet. 9.2 Stand-By Mode This warning is displayed after a 45 minutes idle situation. The instrument will go to stand-by mode after a further 2 minutes. The operator may cancel this by pressing [Menu]. 1116en.gif 1117en.gif If the instrument is in Stand-by mode, the text displayed might not be clear as the back lighter of the LCD display is switched off. The instrument will now perform an auto check and cleaning cycle every 4th hour. 1118en.gif 1119en.gif en01

77 Warning Displays In case one of the reagent containers are empty within the Stand-by mode, one of the above warnings will be displayed. It is essential that new reagent containers are installed, as the 4-hour checking cycle cannot be performed by the instrument. 1120en.gif This warning indicates that an error indication occurred and it was not cleared by the user before the system entered the Stand-by mode. Restart the instrument, cancel indications by pressing [CE] and perform a Prime from menu en.gif When the instrument is in Stand-by mode, and the [Menu] key is pressed, the system will perform a Prime cycle to restore the flow system. This lasts for approx. 2 minutes. 9.3 Reagent Empty 1122en.gif 1123en.gifs The above warnings are displayed in case of an empty reagent container. Replace and perform a Start prime cycle menu 8.1 from the System flow menu, menu en

78 Warning Displays 9.4 Printer and Serial Output 1124en.gif 1125en.gif The warning messages above are related to the connected printer. Either the printer is not connected or busy. 1126en.gif 1127en.gif The above warnings indicate that no printer is connected or no computer is available on the serial output. The Print-key functions were incorrectly programmed. E.g. the serial output was selected but no computer was connected. 1127en.gif The above warning is displayed in case the connected computer serial line is busy and not ready to accept data en01

79 9.5 Auxiliary Warnings/Messages Warning Displays 1129en.gif 1130en.gif The above messages are displayed from the sample memory only. Printing of 19 samples is selected. The second warning shows a question in case a deletion of 19 samples is requested from memory. 1131en.gif The above is displayed during a [Power-On]. The instrument performs a selfcheck, which might last for maximum 15 minutes in case the instrument was exposed to extreme temperature or humidity changes. Normal self check time is 2 minutes. The indicated figures are examples only. 1008en

80 Warning Displays en01

81 10 Calibration and controls Important Do not calibrate the MCV parameter using commercial controls with values given for other analyzers, unless approved by Boule. Not following this might lead to incorrect MCV values on processed samples Important Use the special ID function to identify the specific control blood. See Print control blood id:s on page 70. Not doing so might lead to incorrect WBC values Introduction The instrument has been calibrated at the factory. This applies to all measured parameters. As the instrument has a mechanical fixed metering unit and fixed mechanical micro-volumes; the numerical calibration for the RBC/WBC and PLT are basically stable at all time. Good laboratory practice however, requires regular checks and calibration of the measured parameters. The software calibration factors for all measured parameters can be changed by the user within a large range. This is done to match other analyzers, methods or applications in the laboratory. It is advisable that the performance of the CA620/530 system is checked daily (not calibrated) with a certified control blood. Special attention should be paid to the calculated MCHC parameter (MCHC = HGB/(MCV*RBC)). Recommended calibration periods are twice a year with an 'Hematology Blood Calibrator' certified by Boule. The MCHC parameter can be used as an excellent check on the relation between HGB and HCT. This parameter should be in the range of g/dl. Daily mean values of the samples should always be g/dl. RBC, WBC and PLT Calibration of the above-mentioned parameters is done at the factory with reference standard instruments and volumetric measuring methods. The metering tube is mechanically constant and will remain stable. MCV Calibration of the MCV parameter may be necessary if the temperature environment of the laboratory has changed significantly. (> 10 C) 10.2 Use of Calibrators and Controls The calibration of the instrument can be verified by counting pre-assayed commercial reference control samples or by counting retained patient samples with known reference values from another reference instrument. To ensure the accuracy of the values obtained whenever commercial controls are used: 1. Always re-suspend according to the manufacturer's recommendations. 2. Never use an open vial longer than recommended by the manufacturer or subject any vial to excessive heat or agitation. 3. Verify the condition of controls when received. Make sure that they are cold and not leaking. 4. Do not use a commercial control for calibrating the instrument, use only Calibrators. 1009en

82 Calibration and controls In order not to contaminate the calibrator or control with cleaning solution, be sure to dry the aspiration pipette manually on the outside at each control blood run. Not following this discipline might give dropping values over time on the concentration parameters like RBC, HGB, WBC and PLT. See picture below. Dry the aspiration pipette manually Warning Contamination hazard if contaminated blood enters into open cut. Always wear protective gloves when handling blood samples 1132.bmp 1133.bmp 1134.bmp. Do not push the sample tube against the washing device Correct sample handling 1135.bmp 1136.bmp 10.3 Calibration on a Known Sample The following procedure can be used in case no Hematology Blood Calibrator is available or if the recommended transport conditions of such cannot be met. The RBC, WBC and PLT values can be obtained by using a reference analyzer or a microscope method. The hematocrit should be checked with a micro centrifuge method and the hemoglobin with the cyan meta-hemoglobin method on a reference photometer system. Calculate the MCV by: MCV =HCT/RBC. Important Dry the aspiration pipette manually on the outside at each control blood run and do not push the control or calibrator tube against the upper washing device. See pictures. Not following this discipline might give dropping values for the RBC, HGB, PLT and WBC parameters. Procedure: 1. Make at least 3 HCT determinations with a micro centrifuge and calculate the mean value. 2. Make at least 3 HGB determinations with the cyan meta-hemoglobin method and calculate the mean value. 3. Perform blank counts on the instrument and check that the background is according to the limits stated in chapter Analysing the Sample (Open Tube) on page Aspirate and analyze the known sample at least six times. Print the parameter results of each count en01

83 Calibration and controls 5. Check that the CV values 1 of the measured parameters are within the following ranges: WBC < 2.8% RBC < 1.2% PLT < 5.5% MCV < 0.8% HGB < 1.2% 6. Calculate the difference as per cent between the mean of the results obtained by the instrument and the known values of the sample. 7. Select Calibration Whole Blood from the Setup menu. 8. Scroll to the parameter that has to be adjusted and enter the percentage that was calculated. Use the -/+ key (=right arrow key) to select a - or a + correction. In the example below, the RBC is adjusted with +2.0% 1137en.gif 1138en.gif Hence, the direct calibration method is performed by selecting the parameter to be adjusted with the arrow keys, move the cursor to the field New (cursor field in case of a CA530) and enter the calculated percentage. 9. The last run sample will be recalculated and can be printed on the selected printer output. Important Do not calibrate the instrument using commercial controls or calibrators with values given for other analyzers. This might lead to incorrect calibration of the instrument Calibration Through a Certified Calibrator Recommended calibration periods is twice a year with a Hematology Blood Calibrator certified by Boule. Good laboratory practice involves regular daily checks with blood controls to assure the analyzer and reagents are fully functional. Calibration procedures are carried out to minimize any possible drift caused by tolerances in reagents, environment- changes or instrument. Please note that calibration is only possible on measured parameters e.g.: RBC, WBC, MCV, HGB and PLT. Use a Boule certified PLT-Concentrate calibrator to calibrate the CA620-Cell- Guard for PLT concentrates on the PLT-C and MPV-C parameters. The procedure is identical as described below. 1. The CV values are stated higher than the typical CV of the instrument due to the limited number of sample runs. 1009en

84 Calibration and controls The following calibration procedure is used for the CA620 and the CA620-Cell- Guard, using a Boule certified whole blood calibrator: 1. Run the calibrator 5 times at the open tube inlet. Follow the guidelines shown in Use of Calibrators and Controls on page 81 above. Enter the ID 888+ for each run; entered as 888 and terminated with the right-arrow key. See Print control blood id:s on page 70. In case the calibrator was read by a bar-code reader as outlined in Initializing the Levey-Jennings Plots and Functions on page 87, use the calibrator ID instead of the 888+ entry. To display a quick overview which controls and calibrators are defined, go to menu and press [Enter] to print a list with control/calibrator definitions. 2. Go to menu 5.1. The following is displayed: 1139en.gif The mean value and CV of the last 5 samples are shown. 3. Scroll with the left/right key to the parameter that has to be calibrated and check that the shown CV values 1 are less than: WBC < 4% RBC < 1.8% PLT < 6% MCV < 1% HGB < 1.8% MPV < 5% (if applicable) In case one run should be excluded from the auto calibration to reduce the CV, move the cursor to the specific sample and press [Enter]. The display of Use will show 0 on such sample, indicating that it is not included in the auto calibration. It is also possible to print out a sample by moving the cursor to a sample line and pressing the [Print] button. 1. The CV values are stated higher than the typical CV of the instrument due to the limited number of sample runs en01

85 Calibration and controls 4. Enter the target value read from the assay sheet in the field Target and press [Enter]. The analyzer will calculate the new calibration factor and display this in the field New. 1140en.gif 1141en.gif In the example above, a RBC target value of 4.40 is entered, resulting in a new calibration factor of +1.8%. Next time this menu is recalled, the field Cal% org. will show 1.8%. 5. Scroll to the next parameter to be calibrated using the arrow keys and repeat the above point 4. Note: Sample runs with (SE, DE etc.) are not included in the 5 samples displayed in menu This is shown in the calibration menus as =0 at the sample display Calibration on Pre-Diluted Capillary Blood Calibration for the capillary blood inlet is done in the same way as at the whole blood inlet. Dilute the capillary blood 1:200 e.g. 25 (alternative 20) µl in 5ml diluent, 30µl into 6ml or 40µl in 8ml. Anything between these values is accepted as long as the total volume is between 5 and 8 ml with a dilution ratio of 1:200 to 1:250 and is reproducible. Enter the calibration-menu for pre-diluted capillary blood from menu 5.2 and set the calibration factors. A practical method is to first calibrate the whole-blood inlet. Secondly, run a normal sample at the open tube inlet and note down the parameter values, then use this sample to calibrate the pre-dilute-inlet of the instrument. Note that the predilute-inlet is not factory calibrated, as the setting is dependent on locally used capillaries and dilution ratio Calibration of the MPA The calibration of the Micro Pipette Adapter parameters is similar to the whole blood and/or pre-diluted blood calibration. The recommended calibration method is to run a vein blood sample in the (calibrated) whole blood inlet and to compare the results of the same blood at the MPA inlet. Note that some discrepancies might be observed when comparing to venous blood and Micro Pipette collected blood from a finger puncture (same patient). This is a pre-analytical error that might occur especially if the finger puncture is not done according to the specifications. PLTs might aggregate in case of a bad blood collection procedure. This may also give erroneous results in the total WBC and 3 part differential count. Typical differences between vein and finger puncture collected samples are listed in a report available from your authorized distributor. Please point your browser to: and down load the movie sequences how to operate the MPA with the Micro Lancet as supplied by Boule to minimize such pre-analytical errors. 1009en

86 Calibration and controls 10.7 Calibration of RDW, LYMF and GRAN The calibration of the RDW parameter is performed in a different way due to the calculation of this parameter. The RDW is calibrated only on the last run sample. In case no calibrator with known RDW values is available it is recommended to run 5 normal samples and to calculate the mean of the RDW values. Adjust the RDW calibration menu 5.1 so that the mean value of these 5 samples is %. If RDW values for the calibrator are available, set the RDW to the target value. An example of the CA620 display: 1142en.gif In the example above, the last sample showed RDW=13.8. The new target value is entered as 12.5%. The last sample is recalculated to the target value. Please note that RDW% obtained from blood samples is depending on: a) How the blood was collected. b) Temperature conditions in the lab. c) Mixing conditions of the sample. d) Type and condition of EDTA in the sample tube. It is therefore recommended to adjust the RDW calibration within the local environment. LYMF and GRAN calibration In this menu line a correction factor for LYMF/GRAN can be entered. For example if we want to increase all GRAN readings with +10%, enter +10 and press [Enter]. Lymphocytes will be than be adjusted with -10% and Granulocytes to +10% in respect to the original settings. It is not recommended to use this 'calibration' without instructions from the manufacturer en01

87 11 QC and Blood Controls 11.1 Introduction The CA620 is equipped with a QC memory capable of displaying and printing X- B and Levey-Jennings plots. The X_B algorithm is defined as the Bull's weighted moving average model. Long term drift in the sample parameters MCV, MCH and MCHC are monitored. Levey-Jennings Plots are used to monitor the short term stability of the instrument using blood controls. To use the L-J function, Boule's blood controls must be used and the bar-code reader must be installed to define the parameter ranges and to identify the control. 1157en.gif 1158en.gif Important Do not forget to dry the aspiration pipette manually on the outside at each control blood run and do not push the control sample tube against the upper washing device. Not following this discipline might give dropping values for the RBC, HGB, PLT and WBC parameters. Note: Refer to section Calibration how to handle the blood control and how to dry the aspiration pipette manually in order not to contaminate the blood controls. See Use of Calibrators and Controls on page 81. CA620 and CA530 without bar-code reader. Blood controls must be identified with the ID number 777+ (low), 888+(norm) and 999+ (high). The + sign is entered by pressing the right arrow key. PROG8 (CNTRL8) is used for the definition of discriminator settings and normal range settings. Note that the Levey-Jennings plots are not available in case the bar-code reader is not installed Initializing the Levey-Jennings Plots and Functions To initialize the L-J functions for the blood control(s), the bar-code reader must be installed. Enter menu 7.4 and Follow the instructions on the control assay sheet how to read the blood control data. 1159en.gif 1160en.gif 1156en

88 QC and Blood Controls After the blood control data is read from the assay sheet. Go to menu to view the blood control assay values. See example below. Use the left or right arrow keys to switch between the 2 displays, see picture below. 12 different blood controls from Boule can be defined and stored simultaneously. Use the up/down arrow keys to display another defined control blood en.gif 1162en.gif Press [Enter] at menu to print out all blood control definitions or press [Enter] at menu 5.9 to obtain a short list. Note: In case all 12 control blood definitions/pages are in use, the next control that is read via the bar-code scanner will ask the operator to delete the oldest control samples first before continuing. Also, proper warnings are displayed in case a wrong bar-code is read or if a bar-code is read out of sequence Use of Blood Controls and Levey-Jennings Plots Note: Refer to section Use of Calibrators and Controls on page 81 how to handle the blood control and how to dry the aspiration pipette manually in order not to contaminate the control. Enter the control by reading the ID with the bar-code scanner from the sample tube or enter the blood control ID manually and terminate with the + sign entered with the right arrow key. Aspirate the control sample and wait for the results. The CA620 will identify this ID and match the results with the previous defined control data, see Initializing the Levey-Jennings Plots and Functions on page 87 above. In case a parameter is outside the defined range, a * sign is displayed in front of the parameter value. Press [Print] to print out the results. The printout will show either L or H ' indicating that the parameter result is lower or higher than the assay data. To display the L-J plots, go to menu 7.2 and enter the requested control in the ID field with the bar-code scanner or type the number manually and terminate the control ID with the + sign entered with the right arrow key. A third and most comfortable option is to select the control by using the left/right arrow keys. The display will show the number of control samples selected in line Important Do not forget to dry the aspiration pipette manually on the outside at each control blood run and do not push the control sample tube against the upper washing device. Not following this discipline might give dropping values for the RBC, HGB, PLT and WBC parameters en01

89 QC and Blood Controls To refine the search and selection criteria of the control, enter menu See example below. 1163en.gif 1164en.gif After the select conditions are defined, enter menu to display an overview of the blood control. Use the left or right arrow keys to display the L-J plots. See example below. The L-J plots are displayed for all parameters defined in the control assay sheet except the WBC differential parameter MID. 1165en.gif 1166en.gif To print out the L-J plots, go to menu and press [Enter]. The number of points printed will be depending on the type and resolution of the installed printer. The figures printed on the vertical scale points to the first plotted horizontal line. E.g. in the HGB plot in the figure above, the mean value is The first horizontal line above the mean value is 13.1 (the max limit for this control) and the second horizontal line above the mean value is The number of control runs displayed or printed is always counted from today's date back in time. In the example above, the last run 167 control runs are displayed. Note: In case a control shows an error or warning flag SE, DE, FD, OF, LO, HI, NG, TU, TL or TB; the parameter values of such control run will not be included in the L-J plots Initialization and Use of X-B Function The X-B function in the CA620 follows strictly the Bull algorithm for the parameters MCV, MCH and MCHC. The above parameters should not drift as a function of time within a large patient population. The recommended range setting is +/- 3% from the expected mean value of these parameters. 1156en

90 QC and Blood Controls Enter menu to alter the expected mean values for the MCV, MCH and MCHC. It is recommended that at least the MCV and MCH parameters are set to the expected patient mean values with a range of +/- 3%. 1167en.gif 1168en.gif To display the X-B Plots, enter menu 7.3 see example below. 1169en.gif 1170en.gif By default, all sample data is selected. Refine the display criteria if requested by entering a date window in menu 7.3. Go to menu to display the X-B data summary and use the left or right arrow key to display the plots. 1171en.gif 1172en.gif The data points displayed are always from today's date back in time. In other words, the last data points are displayed. In the example above, 200 points are displayed giving the mean of 4000 samples as each point is the mean value of 20 samples. The figures printed on the vertical scale points to the first plotted horizontal line. E.g. in the MCHC plot in the figure above, the mean value is The first horizontal line above the mean value is 35.0 (the max limit set in menu 7.4.4) and the second horizontal line above the mean value is Go to menu and press [Enter] to printout the X-B Plots. The number of points printed will be depending on the type and resolution of the installed printer. Note: Samples with an error or warning flag SE, DE, OF, LO, HI, NG, TU, TL or TB are not included in the X-B Plots en01

91 QC and Blood Controls 11.5 Display of Blood Control Data To display blood control data, enter menu 7.1 which is analogue to (main) menu 1 but exclusively for control blood. Use the left/right arrow key to display a defined control or type in the control ID manually and use the + sign as the terminator. The + sign is entered with the right arrow key. Line will show the number of control samples selected. Enter menu to refine the search with a date or SEQ (Sequential number) window See example below. 1173en.gif 1174en.gif Enter menu to view the controls and use the up/down arrow keys to scroll through the control memory. Size distributions are not saved and displayed for blood controls. Go to menu to display the mean, SD and CV of the selected data and use menu to print out the selected controls. Menu is used to delete the selected control samples from memory. 1156en

92 QC and Blood Controls en01

93 12 Printer and Serial Output Following is a description of the printer and data outputs of the CA620/530 and the CA620-CellGuard analyzers. The system has 2 outputs. One is of a Centronics format and the second a serial output with RS232 specifications. A standard Centronics cable should be used and connected to a proper printer. The SEIKO DPU 411-typeII /DPU 414, IBM pro-printer compatible, Epson or HP - PCL printer is supported. Note: A printer or serial connection must conform to EN Selecting the Correct Printer Type Press [Menu] until the main menu is displayed and scroll with the arrow keys to line 4. Important If an IBM, Epson or HP compatible printer is used, it is of great importance for the correct printing that the actual printer is supporting the selected data format. Incorrect printing might follow if an improper format or printer is selected. 1150en.gif Press [Print] to printout a list of available formats. Note: Extended printer format settings and user definable print layouts are available. Please refer to appendix for detailed information how to set up a user definable format. This appendix is available from your authorized distributor in the English language only and requires basic understanding of printer protocol, formats and font definitions The Serial Output/Hardware Connections The instrument has an output for connection to a computer (network). The serial output has a male 9 pin DSUB. It fulfils the RS232 specifications. The pinning of the male 9-PIN-DSUB is as follows: 1. N. C. 2. TX-OUTPUT 3. RX-INPUT 4. N.C. 5. GND 6. N.C. 7. CTS-INPUT 8. RTS-OUTPUT 9. N.C. 1010en

94 Printer and Serial Output Use a correct cable that is specified for RS232 data transmission and don't use unnecessary high-speed set-ups on the output. This to avoid checksum errors and to secure a correct data transfer. Enter the menu and select the proper data transmission speed and hand shaking protocol. Note: To enable the serial output of the instrument, the Print functions in point 2 and/ or 3 of the main-menu must be set properly see Printer Configuration on page 49. Connections: PC Computer using a 25 pin RS232 Cable end instrument 9 Pin Female DSUB PC Computer using a 9 pin RS The Serial Output Format The data format is of such an extent that the connected computer system also can trace abnormalities in samples or instrument. On the user-support site, with the http address stated below, an example is given of a typical sample including some error marks. Note that the parameter transmission is independent on language settings. The data transmission is always in English. Preferably, use a computer in terminal mode connected to the instrument to visualize the data and to get familiar with the format. Please put your browser at: And download the available information, such as: 1. Data format description 2. Programming notes Cable end PC 25 Pin Female DSUB Cable end instrument 9 Pin Female DSUB Cable end PC 9Pin 9 DSUB en01

95 13 Maintenance, Shut-Down & Transport Warning Contamination hazard if contaminated blood enters into open cut. Always wear protective gloves when handling blood samples or parts of the instrument that might be contaminated with blood Daily Maintenance The instrument has most of its cleaning procedures automated. This means that the user maintenance is kept to an absolute minimum. Daily user maintenance is therefore limited to a cleaning procedure only on the outside of the instrument. 1. Clean the outside of the aspiration pipette with a pure alcohol solution. This removes possible traces of proteins, bacteria or viruses and increases the effectiveness of the pipette auto-cleaning procedure. 2. Remove possible traces of salt crystals or blood with a disinfecting solution Monthly Maintenance The monthly cleaning procedure has the purpose of securing the correct functioning of the instrument. 1. Switch off the instrument by pulling out the mains cord from the mains supply. 2. Open the front 'door' of the analyzer and inspect the instrument for any trace of salt crystals around aspiration pipette or other directly visible parts. 3. Remove any salt crystal with ONLY distilled water and dry carefully afterwards. 4. Clean the outside cover with a soft detergent. 5. Close the front door and switch on the instrument. 6. Fill a cup with 10 ml 3-5% hypochlorite (bleach), certified by Boule, and enter this as a sample at the pre dilute inlet. Caution Do not disconnect the instrument from the mainssupply as the analyzer performs automatic selfcheck cycles every 4th hour to prevent clogging and bacterial growth in the system. Please call your authorised distributor in case the instrument has to be powered off during a period longer than 4 days. Not doing so might lead to bacterial growth or blockages in the system. 7. Run 2 blank samples of 10ml diluent at the pre-dilute inlet. Report any unusual salt crystal built-up to your authorized dealer Three (3) Month Maintenance To increase the life time of the tubes in the instrument, the following cleaning procedure is strongly recommended. 1. Put both reagent probes in a bottle with Enzymatic Cleaner, authorized by Boule. 2. Execute Menu 8. 2 (Fill system). 3. Wait ca. 30 minutes. 4. Remove the reagent probes from the Enzymatic cleaner and start menu 8.3 (Empty system). 5. Put both probes back in the original reagents and perform menu 8.2 (Fill system). 1011en

96 Maintenance, Shut-Down & Transport 13.4 Short Term Transport The instrument can be transported over short distances without performing any special procedure. Just follow the daily cleaning procedure before the instrument is transported. Take care that the instrument is lifted at the base chassis. Do not stress the front-door. see Mechanical Check and Set-Up on page 41. Pack the instrument in its original package and put it in an upright position during the transport. Make sure that the instrument is never exposed to excessive heat or cold during transport. It is important that the ambient temperature is never below 5 C (41 F). Temperatures below the freezing point (of water) can easily destroy essential parts of the instrument. Humidity over 95% can also cause serious damage to the instrument when it is switched on directly after transport. If condensation has occurred, the instrument should be warmed up at normal ambient temperature for at least 3 hours before it is switched on again. The above transport procedure may only be carried out if the instrument is going to be installed within 12 hours. If the above conditions cannot be met, follow the instructions below to transport the instrument under secure conditions. Caution The transport according to this procedure should only be carried out if the instrument is going to be reinstalled within 12 hours. Not following these guidelines might lead to blockages in the system and/or incorrect functioning during the re-installation Re-packaging and Long Term Transport Whenever the instrument has to be transported over a longer distance or if the system has to be switched off over a period longer than one week, it is necessary to follow the instructions below. 1. Remove the reagent aspiration tubes from their external container/bottle and put them in a bottle with clean distilled water. 2. Press [Menu] so that the main menu is displayed and select menu 8.2. The system is now filled with distilled water, this procedure lasts for approx. 7 minutes. 3. Remove the distilled water bottle. 4. Press Empty system from the System flow menu. The instrument is now emptied from distilled water. Some traces of water will be left however. This is common and correct. 5. Repeat 1 to 4 above. 6. Disconnect the mains supply cable. 7. Insert the valve transport guides that were removed during the installation, see Mechanical Check and Set-Up on page Pack the instrument using the original wooden shipping containers. 9. Mark the containers with DELICATE INSTRUMENT, FRAGILE and THIS SIDE UP en01

97 Maintenance, Shut-Down & Transport 13.6 Permanent Shut-Down and Storing the Instrument To store the instrument follow the packing instructions See Re-packaging and Long Term Transport on page 96. and the following conditions must be met: a) Temperature between 5 and 30 C (41-86 F). b) Humidity should be less than 80%. Warning Contamination hazard. Always wear protective gloves and/or goggles when handling infectous or potentially infectous materials Disposal information Manufacturers recommendation Place the instrument close to a waste container suitable for disposal of used reagents. Check that the drainage is suitable for disposal of chemical and biological waste. Check that the waste tubing is securely fastened in the drain. Note: Customers are advised to be knowledgeable of applicable local, state and federal requirements, and the contents of effluent streams, before disposing of waste in public sewer systems. The disposal material are: used reagents reagents mixed with infectious specimen instrument components of the instrument controls and calibration material 1011en

98 Maintenance, Shut-Down & Transport en01

99 14 Trouble Shooting This chapter gives hints to simplify trouble shooting of the instrument and to minimise external service actions. Also the user might trace a problem to a userrecoverable error or a case where an external service action might be necessary Counting Time HI (TU & TL) A counting time displayed as HI means usually a clogging in the orifice of the analyzer. The counted parameter will have a TU or TL displayed as well. Re-analyze the sample, as the instrument will rinse the orifice automatically. If a counting time HI is displayed frequently, scroll to menu 6.8 and press [Enter] This program will clean the orifice several times. If the above doesn't help, proceed as follows: 1. Put both aspiration tubes in a container with an enzymatic cleaner approved by Boule. 2. Select menu 8.2. Wait minutes and refill the system with diluent and lyzer the same way. Note: In case frequently a TU or TL warning is displayed on the WBC parameters, this might indicate that the pre-dilute inlet is clogged. 1. Attach a syringe with hypochlorite, approved by Boule, to the pre-dilute aspiration inlet and rinse from any possible clogs. 2. Afterwards, enter menu 8.1 (Prime) to restore the flow system. Note: In case the MPA is installed, such blockage might be caused by broken capillary tubes within the MPA and/or connecting tubes. Call your service dept. in such case, see also Analysing the Sample (Micro Pipette Adapter, MPA) on page Counting Time LO A counting time displayed as LO means that there is air in the metering unit of the analyzer. Select menu 8.1 (Prime). The metering units are emptied and refilled with clean diluent HGB Value Flagged with LO The LO indication means that the blank reference during the HGB measurement was too low. This might indicate a bad lamp or a contaminated cuvette. Follow the instructions as shown in Three (3) Month Maintenance on page 95 how to clean the system. In menu 6.2 help functions are available to analyze the HGB system. The lamp voltage and the output of the photometer will be displayed in this menu. 1012en

100 Trouble Shooting The lamp voltage is usually ca. 4.5 Volts and the photometer output ca. 3.5 volts. These values are not critical as long as the photometer output voltage is between 3.2 and 3.8 volts. If the photometer output voltage is lower than 2.5 volt, a LO indication will follow on the HGB parameter value. An automatic adjustment will be performed when digit [1] is pressed on the keyboard. The system will measure the offset, blank and automatically adjust the lamp voltage to obtain a correct reference. This procedure takes ca. 5 minutes HGB Value Flagged with HI The 'HI' indication means that the blank reference voltage in the HGB system is out of range. (The reference voltage is > 3.8 Volts). See HGB Value Flagged with LO on page 99 how to correct this warning HGB Value Flagged with OF This flag is caused by a wrong offset voltage in the HGB system. During an exit from the stand-by mode the HGB offset is measured. If the offset value exceeds 1.0 Volt or if this voltage is < 0.02 Volt, this error mark will be displayed. Cause might be: 1. Heavy stray light in the photometer system. 2. Electronic failure. 3. Mains supply disturbance. The most common failure is that condensation has occurred in the instrument due to transport or heavy variations in the laboratory temperature combined with a high humidity environment. Let the system warm up for at least 1 hour in Stand-by mode High Background PLT High PLT backgrounds are usually found at installation only. Due to transport and having the instrument exposed to the outside air; it is occasionally necessary to make excessive 'blanks' to get the PLT background below 10. Please note that the longer the instrument is in use, the lower the PLT background. If the instrument has been used for a long period of time, a high PLT background might be caused by bacterial growth in the Diluent container. Diluent containers should be stored at temperatures as indicated on the Diluent container label(s) A recommended check to trace the background problem: 1. Replace the diluent container with an unopened fresh vial. 2. Perform a Fill system from menu 8.2 at least 2 times. Select the Noise Test from menu 6.6 to check if any external disturbance is present. All displayed figures (AMPL and FREQ) must be zero. If these values are zero, there is NO line disturbance of any significance and high PLT blank counts are most probably caused by the Diluent en01

101 Trouble Shooting 3. In case the above does not help to reduce the PLT background to acceptable limits, contact your authorized distributor and request bulletin where instructions are given how to decontaminate the instrument Indication Number XXX Displayed In case an indication number is displayed, the sample memory can still be read. Any printout can be performed as well. Note: An indication number is cancelled by pressing the [CE] key. Detailed instructions regarding Indication numbers are given in the service manual at your authorized distributor. Note: The instrument will stop immediately. Further sample processing is disabled until the instrument is disconnected and reconnected to the mains outlet and the error is cancelled as described below. Indication numbers in the instrument can be caused by: 1. A mains power failure during any instrument cycle (count, prime etc.). 2. Turning valve motor failure. 3. Syringe motor failure. 4. Waste pump capacity too low. 5. Blockage due to large particles in the mixing cup device. The following will give the user a first-aid in case an Indication number is displayed: Indication = 1 Date and Time not set. Set within the SETUP Menu. Indication = 2 The Cap Piercing Device was started and immediately aborted by turning the safety cover Counter-Clock-Wise. Press [CE] and the instrument will be operational. Indication = 9 Auto HGB adjustment failed. The cause might be a broken lamp. Contact service department. Indication = One of the internal motors or motor drivers failed. Restart the instrument, cancel any indication with [CE]. If error remains, contact service department. In case of a wrong installation (no CVT in use) this indication might occur due to excessive variation of the mains supply. See Mains Supply Environment on page 39. Indication = The diluent status in the internal mixing cup was incorrect. Restart the instrument, cancel any indication with [CE] and do a Prime from menu 8.1 These errors might be displayed in case there was an Indication previously. Indication = There was a power failure in a cycle, or a cycle was aborted due to a previous indication. 1012en

102 Trouble Shooting Restart the instrument by disconnecting the power and switch on again. Cancel the indication with [CE] and do a Prime from menu 8.1. Indication = Memory failure. Call the service department. Indication = and Hardware or software failure. Contact the service department Cell Diff. Only on a Few Samples To be sure that most of the samples are differentiated into a 3-part WBC differential, the following conditions must be met: 1. Use fresh EDTA blood between 30 min. to 4 hours from sampling. 2. If using pre-diluted samples, they should be analyzed within 5 minutes. 3. The correct reagents should be used, authorized by Boule. 4. The WBC diff. discriminator settings should be correct as advised in section Set discr. WBC on page Cap Piercing Device In case of a needle clogging which occurs occasionally and is dependent on the quality of the used tubes and processed samples, the needle needs to be cleaned. Clogs consist of aggregated cells and/or rubber particles from the rubber stopper of the used tube. Avoid penetrating the same closed tube more than twice as rubber particles from the sample tube cover might contaminate the needle. Cleaning / Replacing the needle If blood never arrives at the blood detector during the sample aspiration, a timeout situation occurs and the instrument warns the operator with a beep signal (10 seconds from the start of aspiration). The results displayed will be zero or far too low on the counted RBC/WBC/HGB and PLT parameters. This may indicate a blockage in the aspiration needle of the Cap Piercing device or a clog in the tubing connected to the needle. Run one blank sample from the Cap Piercing device and connect a syringe as shown in the movie shots at the following address. Select movie shot 2 and 3 for down load en01

103 Trouble Shooting Replacing the needle In case the needle needs to be removed or replaced, proceed as follows: 1. Go to menu 6.2 and select as shown below. Warning Contamination hazard if contaminated blood enters into open cut. Always wear protective gloves when handling blood samples or parts of the instrument that might be contaminated with blood. 1143en.gif 2. Press digit [1]The motor will now move the needle to its far down position (if it was not there already). 3. Switch off the instrument and open the front door. 4. Remove the upper needle locking ring only as indicated below. 1144en.gif Needle Upper locking ring Aspiration tube 1145.bmp 5. Pull the needle down and forwards to remove. 6. Clean or exchange the needle and remount in reverse order. Be sure to reconnect the aspiration tube the correct way. Note: In the displayed menu 6.9.3, the positions 1, 2 and 3 stand for: 1 = Lowest position equals to open tube selection. 2 = Middle position equals to closed tube selection (Can only be reached from position 3). 3= Upper position equals to penetrating position. 1012en

104 Trouble Shooting Clogging in Aspiration Tube In case the sample is not aspirated, a clogging within the aspiration tube might be the source. To minimize these problems, inspect always the sample for visible clogs before aspiration. Please go to and download the movie sequence #1 how to rinse the aspiration tube with a syringe. 1. Switch off the instrument and open the front door. 2. Remove the tube from the shear valve towards the blood detector device. 3. Connect a syringe filled with hypochlorit (ca. 4%) at the shear valve. 4. Move the syringe plunger for- and backwards. 5. Restart the instrument and run a blank. Warning Pin hazard Always make sure that the instrument is switched off when unclogging the aspiration tube. Ignoring this may result in personal injury from moving parts in the instrument en01

105 Index A A.C.D. blood 20 address of distributor 8 address of manufacturer 8 Agglutinated erythrocytes 21 B Barcode reader 69 basophils 21 BD 36 Blood Controls 87, 88 Blood detector setup 68 C CA530 Memory 15 CA620 Memory 15 Chemotherapy 18 Cold agglutinins 19 control sample 15 Controls 81 Cryoglobulins 18 D Date of issue 8 DE 34 discr. program 67 discriminator level 26 discriminator setting 87, 102 Discriminator set-up 34 Disposal 97 E Empty system 95, 96 F FD (Floating Discriminator) 35 Fill system 95, 100 Filling the system with reagents 46 floating discriminator 65 Floating discriminator RBC/ PLT 15 Floating Discriminator Settings 48 Floating PLT/RBC discriminator settings 64 Fuse 12, 15 G GRAN 21, 23, 29, 36, 52, 86 Granulocytes 21 H HCT 19, 30, 52 Hematocrit 13, 19, 30 Hemolyzis 18, 20 HGB 19, 32, 35, 36, 52, 54, 100 HGB measurement 99 HI 99, 100 L Leukemias 18 Levey-Jennings Plots 88 List of materials included in delivery 39 List of materials not included in standard delivery 39 LO 99 LPCR 32 Lymphocyte 21 M MCH 32 MCHC 32 MCV 30, 81 Mean Cell Hemoglobin 13 Mean Cell Volume 13, 30 Mean Platelet Volume 13, 21, 31 Micro Pipette 14, 57 MID 21, 23, 52, 89 MPA 75, 85 MPV 21, 31 Multiple myeloma 18 N needle 102, 103 NG 35 NM 36 NRBC 18 O OF 100 Offset 35 OM 36 P Parameter Flags 33 PCT 32 PDW 31 photometer 33 Platelet Distribution Width 14 Platelet distribution width 31 PLT 14, 16, 19, 20, 23, 25, 27, 30, 31, 48, 65, 66, 70, 100 Print all settings 67 Printer 15, 44, 49, 73, 78, 93 Printer setup menu CA Q QC memory 87 R RBC 16, 19, 20, 25, 27, 28, 30, 52, 65, 81 RDW 20, 86 RDW% 30 RDWa 30 Reagent 17, 40, 42, 71, 77 Red Cell Distribution Width 20, 30 Red Cell Distribution Width (Absolute) 13 RP

106 S Sample Memory 61 SE 34, 36 Serial port setup 69 Setup Menu 64 Stand-By Mode 76 Statistical calculations 61, 62 storage conditions 7 T TB 36 Thrombocytes 20 TL 34, 99 TM 36 Transport 95, 96 TU 34, 99 tubing 102 U Units 51 W Warning flags 15, 33 Warranty 9 Waste connection 40 waste container 97 waste liquid 10, 43 waste outlet 43 Waste pump 101 Waste tube 39 WBC 18, 19, 25, 27, 28, 36, 66, 81 WBC discr. Program 71 whole blood

107

108 Boule Medical AB, P.O. Box 42056, SE Stockholm, Sweden Telephone: , Telefax: mail@boule.se, Web: Article no

Boule Medical AB CA620-CellGuard Page Usermanual V3.7

Boule Medical AB CA620-CellGuard Page Usermanual V3.7 1 File : 620-CellGuard -30-370 Software version V3.7x Article number of this manual : 1504038 Table of contents 1 Identification of hazards & interpretation of results...5 1.1 Interpretation of results...6

More information

Medonic M-series M32 Innovation built on total quality

Medonic M-series M32 Innovation built on total quality Medonic M-series M32 Innovation built on total quality FOR TODAY S HEMATOLOGY LABS Full CBC from one drop of blood Maintenance-free shear valve Unique walk-away Autoloader Make way for Medonic! Packed

More information

User Definable Settings

User Definable Settings User Definable Settings Section 1: User Definable Print Format Settings...1 Section 2: Parameter Unit Selection...7 Section 3: Setup Menu 2...8 Section 4: Setup Menu 3...11 Section 1: User Definable Print

More information

BC Auto Hematology Analyzer. Pleasant Experience in Hematology Testing

BC Auto Hematology Analyzer. Pleasant Experience in Hematology Testing BC-3600 Auto Hematology Analyzer Pleasant Experience in Hematology Testing BC-3600 Auto Hematology Analyzer Labs today are facing a multitude of challenges including limited laboratory budgets, increasing

More information

Next Generation Hematology Analyzer. BeneSphera H33s. Minimum Size, Maximum Capability

Next Generation Hematology Analyzer. BeneSphera H33s. Minimum Size, Maximum Capability Next Generation Hematology Analyzer BeneSphera H33s Minimum Size, Maximum Capability H33s BeneSphera BeneSphera H33s Next Generation Hematology Analyzer What a 3-part should be Avantor s new line of hematology

More information

Hematology Analyzer. User s Manual. Revision 2.17

Hematology Analyzer. User s Manual. Revision 2.17 Abacus junior 5 Hematology Analyzer User s Manual Revision 2.17 TABLE OF CONTENTS 1 INTRODUCTION... 1-1 1.1 Intended Use... 1-1 1.2 General Description... 1-1 1.2.1 The Instrument... 1-1 1.2.2 Patient

More information

Abacus plus. Hematology Analyzer. User s Manual release

Abacus plus. Hematology Analyzer. User s Manual release Abacus plus Hematology Analyzer User s Manual 1.00 release Revision history: Revision Section Modification By At 0.03 All Parallel printer version Support team 19.06.2006. 1.00 1, 7 USB printer version

More information

ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems

ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems Siemens Solutions for Hematology ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems Answers for life. The ADVIA Hematology Family Siemens can now offer a total solution with the ADVIA 360, ADVIA 560, ADVIA

More information

Date Name Signature Issued 06-MAY-2011 Csaba Magyar Checked and approved 17-MAY-2011 Gábor Farkas

Date Name Signature Issued 06-MAY-2011 Csaba Magyar Checked and approved 17-MAY-2011 Gábor Farkas Revision history OM-ACS30-01-1110 Rev. Date Edited by Sections affected Approved by 1.0 2009-06-02 Arpad Gyetvai Initial revision Csaba Magyar 1.1 2010-03-25 Gabor Farkas First review, new GUI screenshots

More information

UM-AJV Abacus Junior Vet User s Manual

UM-AJV Abacus Junior Vet User s Manual UM-AJV-01-276 Abacus Junior Vet User s Manual REVISION-HISTORY Date Name Signature Issued 06/10/2009 Ildiko Losonczi Checked and approved 06/10/2009 Csaba Magyar Abacus Junior Vet Hematology Analyzer User

More information

OM-A Revision history Rev. Date Edited by Sections affected Approved by

OM-A Revision history Rev. Date Edited by Sections affected Approved by OM-A380-01-115 Revision history Rev. Date Edited by Sections affected Approved by 1.0 2010.05.14 Gabor Farkas Initial revision 1.1 2010.07.27. Gabor Farkas Reagent Lock System added, Profile settings added,

More information

World-class veterinary hematology system

World-class veterinary hematology system World-class veterinary hematology system New Exigo H400 CBC from one drop of blood Easy-to-use interface 12 pre-installed animal profiles Robust and reliable Exigo when quality counts! Exigo H400 is a

More information

ELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics

ELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics ELECTIVES MODULES Implement Electives Setup Troubleshooting Basics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions

More information

Total WBC count and differential WBC count HemoCue WBC DIFF system

Total WBC count and differential WBC count HemoCue WBC DIFF system TLM_PRO_029 and Version No. 001 Page 1 of 6 Department: Clinical Sciences Unit: Tropical Laboratory Medicine Total WBC count and differential WBC count HemoCue WBC DIFF system Project/study: Not applicable

More information

HA-86 (89) Auto Hematology Analyzer User s Manual

HA-86 (89) Auto Hematology Analyzer User s Manual HA-86 (89) Auto Hematology Analyzer User s Manual 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.7.17 HA-86 (89) User's Manual How to use this Manual Thank you for

More information

Beckman Coulter Professional Development 2014 Beckman Coulter, Inc. 1of 50

Beckman Coulter Professional Development 2014 Beckman Coulter, Inc. 1of 50 THE BECKMAN COULTER logo, COULTER, DxH, TruColor, and UniCel are trademarks of Beckman Coulter, Inc; COULTER and UniCel are registered in the USPTO. 1of 50 Objectives Flags Codes Messages CBC Parameters

More information

Usermanual Release

Usermanual Release Usermanual Release 1.2.21 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com 1 agile - affordable - accurate Usermanual

More information

FULLY AUTOMATED 2 MICROPLATE ANALYZER

FULLY AUTOMATED 2 MICROPLATE ANALYZER FULLY AUTOMATED 2 MICROPLATE ANALYZER The new Personal Lab,(Plab) is an integration between our unique extensive expertise and information gathered from thousands of installations. The new Plab is innovative

More information

Ultrospec 10 User Manual. English. Deutsch. Français. Español. Italiano

Ultrospec 10 User Manual. English. Deutsch. Français. Español. Italiano English Deutsch Ultrospec 10 User Manual Français Español Italiano Biochrom US Telephone: 1-508-893-8999 84 October Hill Road Toll Free: 1-800-272-2775 Holliston, MA Fax: 1-508-429-5732 01746-1388 support@hbiosci.com

More information

1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader

1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader Specifications & more Elisys Uno > > System Specifications > > Consumables > > Accessories System Overview Cat.. 17350 Analyzer type 1 plate fully automated ELISA analyzer Reagent system Open (Human tests

More information

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34)

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34) WORLDCLASS GLOBAL SUPPORT AUSTRALIA (61) 2 9844 6000 GERMANY (49) 2151 333 625 MEXICO (52) 5 559 1635 SWEDEN (46) 8 564 85900 CANADA (1) 905 819 1234 HONG KONG (852) 2814 7431 NETHERLANDS (31) 2972 30630

More information

Protein Quantification Kit (BCA Assay)

Protein Quantification Kit (BCA Assay) Protein Quantification Kit (BCA Assay) Booklet Item NO. KTD3001 Product Name Protein Quantification Kit (BCA Assay) ATTENTION For laboratory research use only. Not for clinical or diagnostic use Version

More information

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

LIGHT SOURCE Quartz-iodine lamp 12V-20W. SPECIFICATIONS THROUGHPUT Up to 180 tests per hour; Up to 300 tests per hour with ISE unit. REAGENT SYSTEM Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can

More information

RT-7600 Auto Hematology Analyzer User s Manual

RT-7600 Auto Hematology Analyzer User s Manual RT-7600 Auto Hematology Analyzer User s Manual Copyright: Rayto Life and Analytical Sciences Co., Ltd. Address: C&D/4F, 7 th Xinghua Industrial Bldg, Nanhai Rd, Nanshan, Shenzhen 518067, P.R. China Rev:

More information

Hemo Control Analyzer. Point of care device providing immediate, lab quality results for hemoglobin and hematocrit from one simple test

Hemo Control Analyzer. Point of care device providing immediate, lab quality results for hemoglobin and hematocrit from one simple test Hemo Control Analyzer Point of care device providing immediate, lab quality results for hemoglobin and hematocrit from one simple test Product features Easy to use Small sample size (ca. 8μl) Step by step

More information

Magnetic Immunoassay Reader Operator Manual

Magnetic Immunoassay Reader Operator Manual Page 1 of 8 Magnetic Immunoassay Reader Operator Manual Table of contents 1 Introduction...1 2 Magnetic Immunoassay Reader...1 2.1 Contact information and spare parts...1 3 Contents of delivery...1 4 Technical

More information

Products for Health Care

Products for Health Care www.medicacorp.com \EDIC@ Products for Health Care easy inside and out Medica s EasyStat analyzer measures ph, PCO 2, PO 2, Na +, K +, Ca ++, and Hct and calculates additional parameters. Patient parameters,

More information

Fast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education

Fast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education Fast Facts for Operating the scil Vet abc Plus Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education SCIL Vet ABC Plus Fast Facts Table of Contents Start Up Cycle pg. 2 Reagents Status

More information

Hemolyzer 3 NG. User Manual. Version 1.35

Hemolyzer 3 NG. User Manual. Version 1.35 Hemolyzer 3 NG Version 1.35 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com agile - affordable - accurate Contents

More information

Hematology Program (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) Cycle 11: March 2016 February Sample No: 1 Sample Date: 14 Apr 16

Hematology Program (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) Cycle 11: March 2016 February Sample No: 1 Sample Date: 14 Apr 16 Exceptions (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) : March 206 February 207 None at this time. Legend: No Warnings Missing Result Late Results < < > * Amended Result (per participant s request)

More information

Swelab Alfa. A new definition of cell counter precision.

Swelab Alfa. A new definition of cell counter precision. Swelab Alfa. A new definition of cell counter precision. Basic Swelab Alfa Basic gives you a big cell counter for the price of a small one. Featuring many of the attributes of the larger Alfa models, it

More information

EO+ User s Manual. Swelab AC920 EO+ Swelab AC920 EO+ with cap piercer Swelab AC970 EO+

EO+ User s Manual. Swelab AC920 EO+ Swelab AC920 EO+ with cap piercer Swelab AC970 EO+ Swelab EO+ AC970 / AC920 EO+ User s Manual Swelab AC920 EO+ Swelab AC920 EO+ with cap piercer Swelab AC970 EO+ Contents Preface... 5 1 Safety Instruction...7 1.1 Intended Use...7 1.2 Intended user...7

More information

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system Specifications & more > > System Specifications > > Consumables > > Accessories System Overview Cat. No. 16300 Analyzer type 4 plate fully automated ELISA analyzer Reagent system Open (Human tests predefined)

More information

Deckblatt von Marketing / Foto fehlt

Deckblatt von Marketing / Foto fehlt R-Biopharm AG RIDA QUICK SCAN II (V2.5) Deckblatt von Marketing / Foto fehlt Bedienungsanleitung 2017-11-04 2 All rights reserved. This manual may be used only for its intended purpose. It may not be reproduced

More information

Unicel DxH 600 System

Unicel DxH 600 System SETUP MODULES Setup Unicel DxH 600 System Troubleshooting System Overview Additional Topics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU).

More information

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Version 1.06 Metertech Inc. provides this publication as is without warranty of any kind, either express or implied, including, but

More information

USER S MANUAL TULIP DIAGNOSTICS (P) LTD. Gitanjali, Tulip Block, Dr. Antonion De Rego Bagh, Alto Santacruz Bambolim P.O GOA.

USER S MANUAL TULIP DIAGNOSTICS (P) LTD. Gitanjali, Tulip Block, Dr. Antonion De Rego Bagh, Alto Santacruz Bambolim P.O GOA. USER S MANUAL TULIP DIAGNOSTICS (P) LTD. Gitanjali, Tulip Block, Dr. Antonion De Rego Bagh, Alto Santacruz Bambolim P.O GOA. Pin: 403202 Phone: +91 832-2458546/51; Fax: +91 832-2458544; Email: sales@tulipgroup.com

More information

EasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design

EasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design EasyElectrolytes With EasyElectrolytes, Medica has redefined electrolyte analyzer design Simple yes/no prompted operation, combined with a modular design makes EasyElectrolytes reliable and economical.

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Table of Contents 1. PRINCIPLE, APPLICATION AND FEATURES PRINCIPLE APPLICATION FEATURES SPECIFICATIONS AND ACCESSORIE

Table of Contents 1. PRINCIPLE, APPLICATION AND FEATURES PRINCIPLE APPLICATION FEATURES SPECIFICATIONS AND ACCESSORIE 752N UV-Visible Spectrophotometer Operating Instructions This Operating Instructions provides details on the operation, maintenance and troubleshooting of 752N UV-visible spectrophotometer. Please read

More information

COBAS INTEGRA 400 plus

COBAS INTEGRA 400 plus COBAS INTEGRA 400 plus COBAS INTEGRA 400 plus is designed to consolidate testing and increase efficiency while reducing total running costs of the laboratory. The COBAS INTEGRA systems extensive assay

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information

HemoPoint H2. Hemoglobin Analyzer. User Manual. Diagnostics for life

HemoPoint H2. Hemoglobin Analyzer. User Manual. Diagnostics for life HemoPoint H2 Hemoglobin Analyzer User Manual Diagnostics for life HemoPoint H2 Hemoglobin Analyzer User Manual The copyright of this document is protected! Copying and distribution to third parties only

More information

Abacus Arcus. Service Manual. Rev. 2.4

Abacus Arcus. Service Manual. Rev. 2.4 Abacus Arcus Hematology Analyzer Service Manual Rev. 2.4 DIATRON Messtechnik Ges.m.b.H. A-1141 Wien, Ameisgasse 49-51/2. AUSTRIA Tel.: (41) 914-85-00, 911-8-48 Fax: 914-85-07-15 Web: www.diatronltd.com

More information

COULTER STKS Analyzer with Reticulocyte Analysis. Operator s Guide. PN B (March 1995) COULTER CORPORATION Miami, Florida 33196

COULTER STKS Analyzer with Reticulocyte Analysis. Operator s Guide. PN B (March 1995) COULTER CORPORATION Miami, Florida 33196 COULTER STKS Analyzer with Reticulocyte Analysis Operator s Guide PN 4237188B (March 1995) COULTER CORPORATION Miami, Florida 33196 READ ALL PRODUCT MANUALS AND CONSULT WITH COULTER-TRAINED PERSONNEL BEFORE

More information

B5W-LD0101-1/2 B5W- L D Air Quality Sensor. Highly Sensitive and Compact Air Quality Sensor. Model Number Structure. Ordering Information

B5W-LD0101-1/2 B5W- L D Air Quality Sensor. Highly Sensitive and Compact Air Quality Sensor. Model Number Structure. Ordering Information Air Quality Sensor Highly Sensitive and Compact Air Quality Sensor Detection of particles down to 0.5 m in diameter is possible while using an LED light source Features a unique flow path structure that

More information

User manual Code: ORG Name: Alegria

User manual Code: ORG Name: Alegria User manual Code: ORG 300-00 Name: Alegria ORG 300-00_user manual_en_qm113123_2017-07-11_3 page 1 of 51 Content 1. MANUFACTURER... 4 2. IDENTIFICATION... 4 3. INTENDED USE AND PURPOSE... 4 4. CONDITIONS

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

S800 Spectrawave Visible Diode Array Spectrophotometer

S800 Spectrawave Visible Diode Array Spectrophotometer 6 SCANNING VISIBLE INSTRUMENT FOR EDUCATION OPTIMISED FOR THE TEACHING LABORATORY S800 Spectrawave Visible Diode Array Spectrophotometer ABSORBANCE, % TRANSMISSION, CONCENTRATION AND KINETICS LARGE, EASY

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

AnaPrep 12. Instruction Manual. BioChain Institute Inc. Automated Nucleic Acid Preparation System

AnaPrep 12. Instruction Manual. BioChain Institute Inc. Automated Nucleic Acid Preparation System BioChain Institute Inc. Instruction Manual Automated Nucleic Acid Preparation System AnaPrep 12 Catalog No.: Z1321001 Rev. Date: April 30, 2015 Manual No. Z1001 Version: Z1321001UA (MV1.14) For General

More information

Boule Page 1/36 Service manual BM800 Doc No Section 9 Version 02

Boule Page 1/36 Service manual BM800 Doc No Section 9 Version 02 Page 1/36 Section overview 9. General (V02)... 2 9.1 Serial output (hardware)... 2 9.2 Serial output format... 3 9.3 XML serial output format description... 8 9.4 Upgrading software... 35 Page 2/36 9.

More information

FACA-1240 Auto Chemistry Analyzer User s Manual

FACA-1240 Auto Chemistry Analyzer User s Manual FACA-1240 Auto Chemistry Analyzer User s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.01-4.12 I How

More information

Premium Continuous Ink Supply Systems.

Premium Continuous Ink Supply Systems. Premium Continuous Ink Supply Systems. Instruction Manual For Epson Printers R200, R210, R230, R300, R310, RX650 RX510, RX630 157 Union Road, Ascot Vale Victoria 3032 Phone: (+613) 9005 5555 2 Installation

More information

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L Your Parameters Institution: Analyzer Reagent Cat N Reagent Manufacturer Method Group Calibrator Cat n Calibrator Cal Lot # Unit WBC Siemens Advia 12 Siemens 1 9 /L RBC Siemens Advia 12 Siemens 1 12 /L

More information

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-920, IA001723 Nov. 2005 OPERATION MANUAL High Voltage Digitalmeter 149-30A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Electrolyte analyzer i-smart 30

Electrolyte analyzer i-smart 30 Electrolyte analyzer i-smart 30 Overview i-sens electrolyte analyzer, i-smart 30 uses 60 μl of blood sample to measure ions such as Na+, K+, Cl- and hematocrit automatically. Unlike other competitors products,

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

DPP Micro Reader. The DPP Micro Reader is maintenance-free, not configurable by the user and is operated with a single, multi-function button.

DPP Micro Reader. The DPP Micro Reader is maintenance-free, not configurable by the user and is operated with a single, multi-function button. Read this User Guide completely before using the product. Storage conditions: Store between -20 to 80 C (-4 to 176 F) DPP Micro Reader For use under Emergency Use Authorization (EUA) only. For In Vitro

More information

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C Benchmark Plus Microplate Reader User Manual This Instrument for Laboratory Use Only 4100172 Rev C 4100172 Rev C Benchmark Plus System with Incubator Catalog Number 170-6930 Benchmark Plus Reader with

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

The NGAL Test Application Note for Abbott Architect c8000

The NGAL Test Application Note for Abbott Architect c8000 The NGAL Test Application Note for Abbott Architect c8 General parameters Name: NGAL Assay number: *1 Assay version: 1 Assay type: Photometric Assay availability: Enabled Cal version: 1 Reaction definition

More information

VITROS TDM Performance Verifier is prepared from bovine serum to which therapeutic drugs, inorganic salts, and preservatives have been added.

VITROS TDM Performance Verifier is prepared from bovine serum to which therapeutic drugs, inorganic salts, and preservatives have been added. VITROS Chemistry Products TDM Performance Verifier I, II, and III TDM Performance Verifier I, II, and III 896 2540 179 2357 818 2172 Rx ONLY Intended Use For in vitro diagnostic use only. VITROS Chemistry

More information

icore Kiosk system Installation Guide

icore Kiosk system Installation Guide icore Kiosk system Installation Guide The reproduction, transmission or use of this document or its contents is not permitted without express authority. Offenders will be liable for damages. All rights,

More information

DEN-1 Densitometer Suspension turbidity detector

DEN-1 Densitometer Suspension turbidity detector Medical Biological Research & Technologies DEN-1 Densitometer Suspension turbidity detector Operating Manual Certificate for version V.1AW Contents 1. Safety Precautions 2. General Information 3. Getting

More information

INTERFACE SPECIFICATION

INTERFACE SPECIFICATION INTERFACE SPECIFICATION CELL-DYN 1800 SYSTEM LIST NO. 07H79-01 REVISION A ABBOTT DIAGNOSTICS DIVISION Abbott Laboratories Abbott Park, IL 60064, USA INTERFACE SPECIFICATION CELL-DYN 1800 SYSTEM Abbott

More information

TABLE OF CONTENTS. Table of Contents. Table of Figures

TABLE OF CONTENTS. Table of Contents. Table of Figures TABLE OF CONTENTS Table of Contents Table of Figures 1 2 1 Introduction 3 2 Installation 4 2.1 Installation Precautions 4 2.2 Environmental Requirements 4 3 Specifications 4 4 Precautions 4 5 Materials

More information

PerkinElmer Life and Analytical Sciences, Inc. USING THE ALPHASCREEN OMNIBEADS CATALOG NUMBERS: D, M, R

PerkinElmer Life and Analytical Sciences, Inc. USING THE ALPHASCREEN OMNIBEADS CATALOG NUMBERS: D, M, R PerkinElmer Life and Analytical Sciences, Inc. USING THE ALPHASCREEN OMNIBEADS CATALOG NUMBERS: 6760626D, 6760626M, 6760626R For Laboratory Use Only Research Chemicals for Research Purposes Only 2 Precautions

More information

-bio. Densitometer DEN-1B Operating instructions

-bio. Densitometer DEN-1B Operating instructions -bio Densitometer Contents 1 Safety...4 2 General Information...6 3 Getting started...8 4 Operation of...10 5 Maintenance...12 6 Specifications...13 7 Guarantee and service...14 Version 1.01 - May 2012

More information

Product Correction Urgent Immediate Action Required

Product Correction Urgent Immediate Action Required Abbott GmbH & Co. KG Max Planck Ring 2 65205 Wiesbaden, Germany DIAGNOSTICS Urgent Field Safety Notice Product Correction Urgent Immediate Action Required Date d March 8, 2019 Product Product Name List

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

High-end pressure controller Model CPC8000

High-end pressure controller Model CPC8000 Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration

More information

ATOM. Instruction Manual. Head. from software version: 8.

ATOM. Instruction Manual. Head. from software version: 8. Instruction Manual from software version: 8 ATOM Head support@glp.de www.glp.de Contents 1 Description of Device... 3 2 Safety Instructions... 4 3 Mounting... 6 3.1 Operating on the Floor (Upright)...

More information

Objectives 6/15/2015. Review of Customer Communications. Benefits of Immucor s Website

Objectives 6/15/2015. Review of Customer Communications. Benefits of Immucor s Website Review of Customer Communications Presented by: Chris Beritela, MS, BSMT(ASCP)SBB Area Technical Consultant- East Immucor, Inc. The content of this slide presentation is for information and illustration

More information

Blood Hemolysis Detector User Manual

Blood Hemolysis Detector User Manual Blood Hemolysis Detector User Manual Written by: Kayla Marquis, Jordan Seekins, Hanna Anderson, Marie-Louise Doe April 2017 Table of Contents OVERVIEW... 3 GETTING STARTED... 4 CONTENTS IN BOX... 4 ADDITIONAL

More information

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National

More information

USER S MANUAL Madell Technology Corp Walnut Ave. Suite V Buena Park, CA USA Phone:

USER S MANUAL Madell Technology Corp Walnut Ave. Suite V Buena Park, CA USA Phone: DNM-9602A Microplate Reader USER S MANUAL Madell Technology Corp. 7372 Walnut Ave. Suite V Buena Park, CA 90620 USA Phone: 1-877-670-9023 http://www.madelltech.com 1 CONTENTS 1.Introduction 1.1 Characteristics

More information

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured

More information

High-speed peumatic pressure controller Model CPC3000

High-speed peumatic pressure controller Model CPC3000 Calibration technology High-speed peumatic pressure controller Model CPC3000 WIKA data sheet CT 27.55 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

ARRAYMATE. Operating Manual

ARRAYMATE. Operating Manual ARRAYMATE Operating Manual Version 2.1 Alere Technologies 2013 Table of Contents: 1. 1.1 Introduction... 3 Instrument Overview... 3 2. 2.1 Safety Information... 4 Important Operation Notes... 4 2.2 Sign

More information

The right PLT count when it matters. 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe

The right PLT count when it matters. 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe The right PLT count when it matters 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe Agenda 01 02 03 Introduction Identify samples with unreliable PLT counts due to platelet clumps

More information

FACSAria Fusion SORP QUICK REFERENCE GUIDE

FACSAria Fusion SORP QUICK REFERENCE GUIDE FACSAria Fusion SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Admin Password: BDIS 2. Ensure the flow cell access door is open. You will want to

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software Spectrophotometers with Vernier Data Acquisition Software The absorbance of a sample is given as A = log I o I, where I o is the intensity without sample present and I is the intensity with the sample

More information

User Manual MagniLink One

User Manual MagniLink One User Manual MagniLink One LVI Low Vision International Verkstadsgatan 5 Tel: +46 470-727700 info@lvi.se SE-352 46 Växjö Faks: +46 470-727725 www.lvi.se Table of Contents 1 About LVI... 5 2 Introduktion

More information

UV / VIS SPECTROPHOTOMETER

UV / VIS SPECTROPHOTOMETER www.mapada.com.cn A Professional Manufacturer Shanghai Mapada Instruments Co., Ltd. Add: Building D-10, 261# Sanbang Rd., Songjiang Export Processing Zone,Shanghai, 201611 Tel: +86-21-5488 1172 +86-21-5488-0273

More information

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number Operating Manual FSM-2 Field Strength Measuring Gauge Part Number 133033 CONTENTS 1 Application 1 1.1 Safety information 1 2 Identifying parts 2 2.1 Supply 3 2.2 Technical data 3 3 Operation 4 3.1 Switching

More information

DOT MATRIX PRINTER SP6000 SERIES

DOT MATRIX PRINTER SP6000 SERIES DOT MATRIX PRINTER SP6000 SERIES Hardware Manual < Approval: CEL > Trademark acknowledgments SP6000 : Star Micronics Co., Ltd. Notice All rights reserved. Reproduction of any part of this manual in any

More information

Smart Grid Tie Microinverter User Manual

Smart Grid Tie Microinverter User Manual Smart Grid Tie Microinverter User Manual Thanks for choosing Smart Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified by this user

More information

Semi-auto Chemistry Analyzer User s Manual SACA-19900

Semi-auto Chemistry Analyzer User s Manual SACA-19900 Semi-auto Chemistry Analyzer User s Manual SACA-19900 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.010.14 How

More information

3D Printer DIO PROBO. User Guide. Maximizing the clinic operational excellence

3D Printer DIO PROBO. User Guide. Maximizing the clinic operational excellence 3D Printer DIO PROBO User Guide Maximizing the clinic operational excellence 3D Printer DIO PROBO User Guide 3D Printer DIO PROBO User Guide CONTENTS Greetings General Information 10 Applications 11 Workflow

More information

The Martin Experience. Martin Audio CMX1A Cinema Controller MARTIN AUDIO. All material Martin Audio Ltd. Subject to change without notice.

The Martin Experience. Martin Audio CMX1A Cinema Controller MARTIN AUDIO. All material Martin Audio Ltd. Subject to change without notice. CONTENTS () Page No 1 INTRODUCTION 2 2 UNPACKING 2 3 MAINS CONNECTION 3 4 INPUT CONNECTIONS 4 5 OUTPUT CONNECTIONS 4 6 CMX1A OPERATION 5 7 SCREEN COMPENSATION EQ 5 8 WARRANTY 5 9 TECHNICAL SPECIFICATIONS

More information

EXCLUSIVE. Validated for chemical/ biological hazards* egross pro-x. Simply the most innovative, safe grossing workstation MILESTONE

EXCLUSIVE. Validated for chemical/ biological hazards* egross pro-x. Simply the most innovative, safe grossing workstation MILESTONE EXCLUSIVE Validated for chemical/ biological hazards* egross pro-x Simply the most innovative, safe grossing workstation MILESTONE H E L P I N G P A T I E N T S ERGONOMIC The egross pro-x This all-in-one

More information

1. Safety Precautions

1. Safety Precautions 2 Contents 1. Safety Precautions... 4 2. General Information... 5 3. Getting started... 6 4. Operation... 7 5. Specifications... 8 6. Maintenance... 9 7. Warranty and Claims... 10 8. EU Declaration of

More information

Sartorius XQ 6100, XQ 6100 B.

Sartorius XQ 6100, XQ 6100 B. Sartorius XQ 6100, XQ 6100 B. Electronic Paint Mixing Scales Installation and Operating Instructions Sartorius XQ 6100, XQ 6100 B. Please read these installation and operating instructions carefully before

More information

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual Part No. MANSRV411i_171114 Page 1 of 16 S by S Instruments, Inc. SRV411i Small Animal Floor Scale Operating and Service Manual Part No. MANSRV411i_171114 Page 2 of 16 TABLE OF CONTENTS TABLE OF FIGURES...2

More information

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd. W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd. 1 2 Safety Information Please read the following safety information carefully before operating the machine. Information includes

More information

Hematology Analyzer. Service Manual. 3.0 release

Hematology Analyzer. Service Manual. 3.0 release Abacus junior Abacus junior vet Abacus junior B Hematology Analyzer Service Manual.0 release DIATRON Messtechnik Ges.m.B.H. A-4 Wien, Ameisgasse 49-5/2. AUSTRIA Tel.: (4) 94-85-00, 9-8-48 Fax: 94-85-07-5

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information

Hemolyzer. 5 NG (closed mode) User Manual. Version 1.35

Hemolyzer. 5 NG (closed mode) User Manual. Version 1.35 Hemolyzer 5 NG (closed mode) User Manual Version 1.35 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com agile -

More information