Beckman Coulter Professional Development 2014 Beckman Coulter, Inc. 1of 50

Size: px
Start display at page:

Download "Beckman Coulter Professional Development 2014 Beckman Coulter, Inc. 1of 50"

Transcription

1 THE BECKMAN COULTER logo, COULTER, DxH, TruColor, and UniCel are trademarks of Beckman Coulter, Inc; COULTER and UniCel are registered in the USPTO. 1of 50

2 Objectives Flags Codes Messages CBC Parameters Cellular Interference Differential Parameters NRBC Parameters Retic Parameters 2of 50

3 Flags * These Flags are also associated with System Messages. See System Messages in HELP for more information. 3of 50

4 Codes 4of 50

5 Messages Messages Results related: Suspect: messages are generated by internal algorithms to convey that a clinical condition may exist with a specimen based on an abnormal cell population or distribution. System: messages indicate an event that may affect the operation of a system, requires operator notification and or entry into a History Log. Most accompanied by an R (review) flag Some are accompanied by N or P flags Definitive: defined by the Operator 5of 50

6 Messages Exception or System Status Messages Exception: anything with an exception may or may not be released depending on your lab s release rules criteria. An exception is the default test order. System Status: an event that may affect system operation. Accompanied by operator notification and entry into log. 6of 50

7 Examples 7of 50

8 CBC Parameters 8of 50

9 Data Fusion 9of 50

10 Cellular Interference System message Cellular Inter WBC & associated parameters, or TNC, flagged with R The results are only flagged if we are uncertain of the correction, or can t correct (not just because a correction occurred). Suspect message Cellular Inter WBC & associated parameters, or TNC, flagged with R For CBC or CBC/Retic panels only, when NRBC are detected but not reported. 10 of 50

11 Red Cell Messages Suspect message Dimorphic Reds Data pattern consistent with the presence of multiple red cell populations Suspect message Red Cell Agglut Data pattern consistent with the presence of agglutinated red cells 11 of 50

12 RBC Fragments/Microcytes Suspect message RBC Frag/Micro Pattern observed consistent with the presence of RBC fragments and/or microcytic red cells. 12 of 50

13 Giant Platelets Suspect message Giant Platelet May be accompanied by System message specific to platelet results Giant Platelet data pattern observed 13 of 50

14 Platelet Clumps System message Platelet Clumps PLT & associated parameters flagged with R Clumped platelet data pattern observed 14 of 50

15 Platelet Messages System message PLT Inter: Debris PLT & associated parameters flagged with R PLT requires review due to the possible presence of an interference with small platelets System message RBC-PLT Overlap PLT & associated parameters flagged with R PLT histogram shows a possible interference with larger platelets 15 of 50

16 WBC Interference from HGB System message WBC Inter: HGB HGB & associated parameters flagged with R HGB may not be adequately corrected for WBC interference 16 of 50

17 Differential Parameters 17 of 50

18 One Cell at a Time... WBCs are hydrodynamically focused FLOW CELL S H E A T H -F L U ID IN SAMPLE DILUTION SENSING AREA SHEATH FLUID SHEATH-FLUID IN SAMPLE IN 18 of 50

19 Flow Cytometric Digital Morphology Multiple angles of light scatter, captures 10X more data than previously possible AL2 (axial light loss) LALS (lower angle LS) LMALS (lower med angle LS) UMALS (upper med angle LS) MALS (median angle LS) 19 of 50

20 Flow Cytometric Digital Morphology 20 of 50

21 Differential Parameters MONO NEUTS EOS LYMPH BASO 21 of 50

22 Abnormal Cell Distribution MO Blasts 2 NE Blasts 3 Immature Granulocytes 4 Band Neutrophils 5 LY Blasts 6 Variant Lymphocytes 7 Small Lymps / Low Opacity 8 Non-White Cells 8 22 of 50

23 LY Blast 5PD1 5PD2 Normal 5PD1 Suspect message LY Blast Blasts suspected in the LY area of the dataplot Data pattern consistent with possible presence of very immature cells 23 of 50

24 MO Blast 5PD1 5PD2 Normal 5PD1 Suspect message MO Blast Blasts suspected in the MO area of the dataplot Data pattern consistent with possible presence of very immature cells 24 of 50

25 NE Blast 5PD1 5PD2 Normal 5PD1 Suspect message NE Blast Blasts suspected in the NE area of the dataplot Data pattern consistent with possible presence of very immature cells 25 of 50

26 Immature Granulocytes 5PD1 5PD2 Normal 5PD1 Suspect message Imm Grans [Metamyelocytes, myelocytes &/or promyelocytes] or [myelocytes & promyelocytes] Variable sensitivity with default set at high 26 of 50

27 Left Shift 5PD1 5PD2 Normal 5PD1 Suspect message Left Shift Metamyelocytes, without more immature granulocytes Variable sensitivity with default at high Can be disabled 27 of 50

28 Variant LY 5PD1 5PD2 Normal 5PD1 Suspect message Variant LY Variant (viral), atypical or abnormal LY suspected Variable sensitivity with default at high 28 of 50

29 Abnormal Diff Pattern 5PD1 5PD2 Normal 5PD1 System message Abn Diff Pattern Results do not match any known template All Diff results accompanied by R flag 29 of 50

30 NRBC 5PD1 5PD2 Normal 5PD1 Suspect message NRBC NRBC suspected in the signature position of the dataplot Only in condition where the NRBC module is disabled and the panel includes a Diff 30 of 50

31 Aged Sample 5PD1 5PD2 Normal 5PD1 System message Aged Sample All Diff results accompanied by R flag The results are only flagged if we are unable to give a correct differential, not just because aging is present. 31 of 50

32 Excessive Debris 5PD1 5PD2 System message Excessive Debris: D All Diff results accompanied by R flag 32 of 50

33 NE-EO Overlap 5PD1 5PD2 System message NE-EO Overlap All Diff results flagged with R Population shift observed (NE and EO not in correct spatial location) 33 of 50

34 MO-NE Overlap 5PD1 5PD2 System message MO-NE Overlap All Diff results flagged with R Population shift observed (MO and NE not in correct spatial location) 34 of 50

35 Low Events: D 5PD1 5PD2 System message Low Events: D Not enough events available for differential 35 of 50

36 High Opacity Events 5PD1 5PD2 System message High OP Events All Diff results accompanied by R flag Interference in Opacity that has been observed with bone marrow samples or specimens with platelet clumps. 36 of 50

37 Low RMALS Events 5PD1 5PD2 System message Low RMALS Events All Diff results flagged with R RMALS mode value is too low 37 of 50

38 NRBC Parameters PLT/DEBRIS WBC NRBC 38 of 50

39 Abnormal NRBC Pattern NRBC1 NRBC2 System message Abn NRBC Pattern NRBC & associated parameters flagged with R Fits no known pattern Normal nrbc 39 of 50

40 NRBC-LY Overlap System message NRBC-LY Overlap NRBC & associated parameters flagged with R Couldn t separate NRBC from small LY during analysis Normal nrbc NRBC1 NRBC2 40 of 50

41 NRBC Interference System message NRBC Inter NRBC & associated parameters flagged with R Significant amount of interference in NRBC regions that are not NRBC Normal nrbc NRBC1 NRBC2 41 of 50

42 Miscellaneous NRBC Messages Detected by Hardware, not algorithm Flow Cell Clog: N System Event: N 42 of 50

43 Reticulocyte Parameters WBC S MATURE RBC S RETICS PLT/DEBRIS 43 of 50

44 Abnormal Hemoglobin Normal Retic Suspect message Abn Hemoglobin Others category = green (~ platelets) & orange (not cleared) particles. Indicates a possible clearing problem in the presence of abnormal hemoglobin 44 of 50

45 Sickled Cells Suspect message Sickled Cells Data pattern consistent with sickled cells Normal Retic 45 of 50

46 Retic System Messages System message RET-RBC Overlap RET & associated parameters flagged with R. Unclear separation of retics & mature red cells. System message RET Inter: PLT RET & associated parameters flagged with R. The platelet population may have interfered with the RET. 46 of 50

47 Nucleated Cells System message Nucleated Cells RET & associated parameters flagged with R NRBC or small WBC (especially small LY as in CLL) are visible in the dataplot (blue) and may have interfered with RET measurement 47 of 50

48 Flow Cell Clog System message Flow Cell Clog: R RET and associated parameters flagged with R Hardware detected a flow cell clog during analysis It is possible to have a flow cell clog that is severe enough to inhibit data [:::::]. 48 of 50

49 System Event During Retic Examples include (but are not limited to): Laser Offset Voltage failure Temperature Out of Range System message System Event: R RET & associated parameters flagged with R Hardware parameters were out of limit for an item that could affect RET analysis (e.g. voltage, temperature, pressure). 49 of 50

50 THE END! 50 of 50

Unicel DxH 600 System

Unicel DxH 600 System SETUP MODULES Setup Unicel DxH 600 System Troubleshooting System Overview Additional Topics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU).

More information

Intelligent Automation

Intelligent Automation Intelligent Automation Using Automation, Middleware and Digital Imaging to Transform Hematology Workflow and Outcomes UTMB Major Academic Health Science Center 6 hospitals Level 1 trauma center 24-room

More information

Processing haematological data on a network environment

Processing haematological data on a network environment Malaysian J Pathol 1995; 17(2): 77-81 Processing haematological data on a network environment ZAINAL AG DMLT* and SK CHEONG FRCP,FRCPA Department of Pathology and Medicine*, Faculty of Medicine, Universiti

More information

ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems

ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems Siemens Solutions for Hematology ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems Answers for life. The ADVIA Hematology Family Siemens can now offer a total solution with the ADVIA 360, ADVIA 560, ADVIA

More information

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L

Lab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L Your Parameters Institution: Analyzer Reagent Cat N Reagent Manufacturer Method Group Calibrator Cat n Calibrator Cal Lot # Unit WBC Siemens Advia 12 Siemens 1 9 /L RBC Siemens Advia 12 Siemens 1 12 /L

More information

Sysmex WAM v4.1 Rule Overview Workshop

Sysmex WAM v4.1 Rule Overview Workshop Sysmex WAM v4.1 Rule Overview Workshop Intermountain Health Care User Group Meeting April 22, 2014 Agenda Rule Overview Common Rule Types Rule Creation Procedures Intermountain Health Rule Examples 1 Sysmex

More information

CELL-DYN Sapphire TM Interface Set-up Procedure for Accelerator DM Application Software Version 1.0

CELL-DYN Sapphire TM Interface Set-up Procedure for Accelerator DM Application Software Version 1.0 Abbott Accelerator TM Decision Manager TM Page 1 of 20 CELL-DYN Sapphire TM Interface Set-up Procedure for Accelerator DM Application Software Version 1.0 Purpose Prepare the Accelerator Decision Manager

More information

UniCel DxH 600 Coulter Cellular Analysis System Training Modules

UniCel DxH 600 Coulter Cellular Analysis System Training Modules UniCel DxH 600 Coulter Cellular Analysis System Training Modules This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions

More information

December 2002 CAP TODAY / 37

December 2002 CAP TODAY / 37 December 2002 CAP TODAY / 37 Part 1 of 9 Abbott Diagstics Hematology Business Unit 5440 Patrick Henry Dr. Santa Clara, CA 95054 800-933-5535 www.abbott.com Cell-Dyn 3200 1997/1997 >700/>1,500/$16 standard

More information

COULTER STKS Analyzer with Reticulocyte Analysis. Operator s Guide. PN B (March 1995) COULTER CORPORATION Miami, Florida 33196

COULTER STKS Analyzer with Reticulocyte Analysis. Operator s Guide. PN B (March 1995) COULTER CORPORATION Miami, Florida 33196 COULTER STKS Analyzer with Reticulocyte Analysis Operator s Guide PN 4237188B (March 1995) COULTER CORPORATION Miami, Florida 33196 READ ALL PRODUCT MANUALS AND CONSULT WITH COULTER-TRAINED PERSONNEL BEFORE

More information

No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(04)/7M Date :- 28/07/2016

No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(04)/7M Date :- 28/07/2016 No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(04)/7M Date :- 28/07/2016 E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR 1. EQ-C-74/16-17 Automated 5 part Deferential Cell Counter 2. EQ-C-93/16-17

More information

The right PLT count when it matters. 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe

The right PLT count when it matters. 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe The right PLT count when it matters 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe Agenda 01 02 03 Introduction Identify samples with unreliable PLT counts due to platelet clumps

More information

Boule Medical AB CA620-CellGuard Page Usermanual V3.7

Boule Medical AB CA620-CellGuard Page Usermanual V3.7 1 File : 620-CellGuard -30-370 Software version V3.7x Article number of this manual : 1504038 Table of contents 1 Identification of hazards & interpretation of results...5 1.1 Interpretation of results...6

More information

ELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics

ELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics ELECTIVES MODULES Implement Electives Setup Troubleshooting Basics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions

More information

BC Auto Hematology Analyzer. Pleasant Experience in Hematology Testing

BC Auto Hematology Analyzer. Pleasant Experience in Hematology Testing BC-3600 Auto Hematology Analyzer Pleasant Experience in Hematology Testing BC-3600 Auto Hematology Analyzer Labs today are facing a multitude of challenges including limited laboratory budgets, increasing

More information

UniCel DxH 800 Coulter Cellular Analysis System Training Modules

UniCel DxH 800 Coulter Cellular Analysis System Training Modules Training Modules This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions for Use Manual supersedes information in

More information

Next Generation Hematology Analyzer. BeneSphera H33s. Minimum Size, Maximum Capability

Next Generation Hematology Analyzer. BeneSphera H33s. Minimum Size, Maximum Capability Next Generation Hematology Analyzer BeneSphera H33s Minimum Size, Maximum Capability H33s BeneSphera BeneSphera H33s Next Generation Hematology Analyzer What a 3-part should be Avantor s new line of hematology

More information

RAA040AEN OUTPUT FORMATS PENTRA 80 / XL80

RAA040AEN OUTPUT FORMATS PENTRA 80 / XL80 RAA040AEN OUTPUT FORMATS PENTRA 80 / XL80 Table of Contents -> Introduction page 3 -> Connection, page 4 -> ASTM Format page 6 -> ABX Format page 22 RAA040AEN HORIBA ABX PROPERTY 2 Introduction ASTM Format

More information

Output format for haematology analyzers Pentra 60/Pentra 60C+/Pentra 80/Pentra 80 XL/Pentra 120 Micros/Micros 60/Micros CRP

Output format for haematology analyzers Pentra 60/Pentra 60C+/Pentra 80/Pentra 80 XL/Pentra 120 Micros/Micros 60/Micros CRP HORIBAABX Montpellier Output format for haematology analyzers Pentra 60/Pentra 60C+/Pentra 80/Pentra 80 XL/Pentra 120 Micros/Micros 60/Micros CRP RAA024HA Chapter 4: ABX Format ASTM Format is recommended

More information

HA-86 (89) Auto Hematology Analyzer User s Manual

HA-86 (89) Auto Hematology Analyzer User s Manual HA-86 (89) Auto Hematology Analyzer User s Manual 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.7.17 HA-86 (89) User's Manual How to use this Manual Thank you for

More information

Usermanual Release

Usermanual Release Usermanual Release 1.2.21 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com 1 agile - affordable - accurate Usermanual

More information

Kit Contents FH9-06 FH9-10 BCP-11 BCP-20 CD-ROM. Important: Before You Begin. New for this Mailing

Kit Contents FH9-06 FH9-10 BCP-11 BCP-20 CD-ROM. Important: Before You Begin. New for this Mailing Comprehensive Hematology Survey Automated Differential FH9 FH9P 2FH9 FH9-B 2014 Kit Instructions CAP 2014 Table of Contents Kit Contents Kit Contents... 1 Important: Before You Begin... 1 Detailed Testing

More information

INDEX TECHNICAL SERVICE BULLETIN

INDEX TECHNICAL SERVICE BULLETIN CELL-DYN 3200/SL (109) Index ABBOTT ADD INDEX TECHNICAL SERVICE BULLETIN PRODUCT: CELL-DYN 3200/SL (109) DATE: 29-JUL-98 TSB # IMPLEMENTATION SUBJECT EFFECTIVITY DATE 109-010 I - See TSB CELL-DYN 3200/SL

More information

Automated Red Blood Cell Differential Analysis on a Multi-Angle Light Scatter/Fluorescence Hematology Analyzer

Automated Red Blood Cell Differential Analysis on a Multi-Angle Light Scatter/Fluorescence Hematology Analyzer Cytometry Part B (Clinical Cytometry) 56B:43 54 (2003) Automated Red Blood Cell Differential Analysis on a Multi-Angle Light Scatter/Fluorescence Hematology Analyzer Young Ran Kim, 1 * Ronny van t Oever,

More information

Contents. Preface Safety Instruction Specifications Measuring Principles Parameter Flags... 33

Contents. Preface Safety Instruction Specifications Measuring Principles Parameter Flags... 33 User s Manual Medonic CA620 + MPA + AD Medonic CA620 + MPA Medonic CA620 Medonic CA530 + MPA + AD Medonic CA530 + MPA Medonic CA530 Medonic CA620-CellGuard + MPA + AD Medonic CA620-CellGuard + MPA Contents

More information

OUTPUT FORMATS. Pentra DX / DF Nexus RAA048AEN

OUTPUT FORMATS. Pentra DX / DF Nexus RAA048AEN OUTPUT FORMATS Pentra DX / DF Nexus RAA048AEN Revisions Table of contents -> Introduction, page 3 Table 1: Revisions Index Software revision Chapter, page Date A V1.2.0 All 15/08/2013 -> Physical connection

More information

Difftote 12 A sophisticated microprocessor based counter for the counting of Leucocyte cells when performing the Differential count.

Difftote 12 A sophisticated microprocessor based counter for the counting of Leucocyte cells when performing the Differential count. Difftote 12 A sophisticated microprocessor based counter for the counting of Leucocyte cells when performing the Differential count. Operation Manual Index page 22 1 INTRODUCTION The Difftote 12 is a sophisticated

More information

Fast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education

Fast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education Fast Facts for Operating the scil Vet abc Plus Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education SCIL Vet ABC Plus Fast Facts Table of Contents Start Up Cycle pg. 2 Reagents Status

More information

World-class veterinary hematology system

World-class veterinary hematology system World-class veterinary hematology system New Exigo H400 CBC from one drop of blood Easy-to-use interface 12 pre-installed animal profiles Robust and reliable Exigo when quality counts! Exigo H400 is a

More information

Total WBC count and differential WBC count HemoCue WBC DIFF system

Total WBC count and differential WBC count HemoCue WBC DIFF system TLM_PRO_029 and Version No. 001 Page 1 of 6 Department: Clinical Sciences Unit: Tropical Laboratory Medicine Total WBC count and differential WBC count HemoCue WBC DIFF system Project/study: Not applicable

More information

APS (Automatic Population Separator)

APS (Automatic Population Separator) Infinicyt provides a list of very powerful tools for research and diagnosis of haematological diseases through flow cytometry data analysis. The features that most distinguish Infinicyt software from other

More information

Remisol Advance for Hematology Customers

Remisol Advance for Hematology Customers Remisol Advance for Hematology Customers This Training Guide belongs to: Rev. C (June 2015) i of iv Beckman Coulter Professional Development WARNINGS AND PRECAUTIONS This training guide is not intended

More information

Parameter / Paramètre. (1) Assay values provided by EUROCELL Diagnostics, France. Valeurs fournies par EUROCELL Diagnostics, France.

Parameter / Paramètre. (1) Assay values provided by EUROCELL Diagnostics, France. Valeurs fournies par EUROCELL Diagnostics, France. CBC- Plus IBRATION VALUES AND ACCEPTABLE RANGES VALEURS DE IBRATION ET LIMITES 1 s : ABX (1) ABX WBC/GB 10 3 /µl & 10 9 /L 9,3 9,1-9,5 Pentra 60 Series RBC/GR 10 6 /µl & 10 12 /L 4,81 4,73-4,89 Pentra

More information

BD FACSMelody Cell Sorter Quick Reference Guide

BD FACSMelody Cell Sorter Quick Reference Guide BD FACSMelody Cell Sorter Quick Reference Guide This guide contains instructions for using the BD FACSMelody cell sorter with BD FACSChorus software version. and later. Workflow Overview The following

More information

Hematology Program (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) Cycle 11: March 2016 February Sample No: 1 Sample Date: 14 Apr 16

Hematology Program (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) Cycle 11: March 2016 February Sample No: 1 Sample Date: 14 Apr 16 Exceptions (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) : March 206 February 207 None at this time. Legend: No Warnings Missing Result Late Results < < > * Amended Result (per participant s request)

More information

Date Name Signature Issued 06-MAY-2011 Csaba Magyar Checked and approved 17-MAY-2011 Gábor Farkas

Date Name Signature Issued 06-MAY-2011 Csaba Magyar Checked and approved 17-MAY-2011 Gábor Farkas Revision history OM-ACS30-01-1110 Rev. Date Edited by Sections affected Approved by 1.0 2009-06-02 Arpad Gyetvai Initial revision Csaba Magyar 1.1 2010-03-25 Gabor Farkas First review, new GUI screenshots

More information

Boule Page 1/36 Service manual BM800 Doc No Section 9 Version 02

Boule Page 1/36 Service manual BM800 Doc No Section 9 Version 02 Page 1/36 Section overview 9. General (V02)... 2 9.1 Serial output (hardware)... 2 9.2 Serial output format... 3 9.3 XML serial output format description... 8 9.4 Upgrading software... 35 Page 2/36 9.

More information

OM-A Revision history Rev. Date Edited by Sections affected Approved by

OM-A Revision history Rev. Date Edited by Sections affected Approved by OM-A380-01-115 Revision history Rev. Date Edited by Sections affected Approved by 1.0 2010.05.14 Gabor Farkas Initial revision 1.1 2010.07.27. Gabor Farkas Reagent Lock System added, Profile settings added,

More information

0.1-4 mg/dl or μmol/l or mmol/l 152 Upper limit of normal for your institution creatinine

0.1-4 mg/dl or μmol/l or mmol/l 152 Upper limit of normal for your institution creatinine s Recipient Baseline Data (Form 2000) 141 AST (SGOT) 0-200 U/L or 0-3.2 μkat/l 144 Total serum bilirubin 0.2-15 mg/dl or 3.5-263 μmol/l 146 Upper limit of normal for your institution - bilirubin 0.2-2.5

More information

Output format. 1. ABX format principles PIN assignments ARGOS format principles ASTM Specifications...

Output format. 1. ABX format principles PIN assignments ARGOS format principles ASTM Specifications... Output format 1. ABX format principles...6-2 1.1. Message structure...6-2 1.2. Details about the structure... 6-2 1.3. Identifier list and their formats...6-3 1.4. Pathology...6-5 1.5. Histograms and matrix...6-8

More information

Hematology Analyzer. User s Manual. Revision 2.17

Hematology Analyzer. User s Manual. Revision 2.17 Abacus junior 5 Hematology Analyzer User s Manual Revision 2.17 TABLE OF CONTENTS 1 INTRODUCTION... 1-1 1.1 Intended Use... 1-1 1.2 General Description... 1-1 1.2.1 The Instrument... 1-1 1.2.2 Patient

More information

CellaVision Proficiency Software

CellaVision Proficiency Software CellaVision Proficiency USER S MANUAL 2.3 CellaVision Proficiency Preface CellaVision is a trademark of CellaVision AB. All other trademarks used in this document are property of their respective owners.

More information

CELL-DYN 1800 Field Service Training Workbook

CELL-DYN 1800 Field Service Training Workbook CELL-DYN 1800 Field Service Training Workbook Abbott Laboratories Abbott Park, IL. 60064 2003 Abbott Laboratories 96919-101 04/09/03 Proprietary Statement Copyright 2003, Abbott Laboratories Diagnostics

More information

Medonic M-series M32 Innovation built on total quality

Medonic M-series M32 Innovation built on total quality Medonic M-series M32 Innovation built on total quality FOR TODAY S HEMATOLOGY LABS Full CBC from one drop of blood Maintenance-free shear valve Unique walk-away Autoloader Make way for Medonic! Packed

More information

User Definable Settings

User Definable Settings User Definable Settings Section 1: User Definable Print Format Settings...1 Section 2: Parameter Unit Selection...7 Section 3: Setup Menu 2...8 Section 4: Setup Menu 3...11 Section 1: User Definable Print

More information

Resveratrol mitigates lipopolysaccharide-mediated acute. inflammation in rats by inhibiting the TLR4/NF-κBp65/MAPKs.

Resveratrol mitigates lipopolysaccharide-mediated acute. inflammation in rats by inhibiting the TLR4/NF-κBp65/MAPKs. Resveratrol mitigates lipopolysaccharide-mediated acute inflammation in rats by inhibiting the TLR4/NF-κBp65/MAPKs signaling cascade Guangxi Wang a,1, Zhiqiang Hu b,1, Qiuting Fu a,1, Xu Song a,1, Qiankun

More information

INTERFACE SPECIFICATION

INTERFACE SPECIFICATION INTERFACE SPECIFICATION CELL-DYN 1800 SYSTEM LIST NO. 07H79-01 REVISION A ABBOTT DIAGNOSTICS DIVISION Abbott Laboratories Abbott Park, IL 60064, USA INTERFACE SPECIFICATION CELL-DYN 1800 SYSTEM Abbott

More information

Abacus plus. Hematology Analyzer. User s Manual release

Abacus plus. Hematology Analyzer. User s Manual release Abacus plus Hematology Analyzer User s Manual 1.00 release Revision history: Revision Section Modification By At 0.03 All Parallel printer version Support team 19.06.2006. 1.00 1, 7 USB printer version

More information

Blood Microscopic Image Analysis for Acute Leukemia Detection

Blood Microscopic Image Analysis for Acute Leukemia Detection I J C T A, 9(9), 2016, pp. 3731-3735 International Science Press Blood Microscopic Image Analysis for Acute Leukemia Detection V. Renuga, J. Sivaraman, S. Vinuraj Kumar, S. Sathish, P. Padmapriya and R.

More information

Communication Links Between the Data Manager and a Host Computer

Communication Links Between the Data Manager and a Host Computer T ADVIA 120 Hematology System Communication Links Between the Data Manager and a Host Computer Publication No. TN9-7865-02 / June 2000 Publication Change Record Publication Number Date TN9-7865-00 December

More information

UM-AJV Abacus Junior Vet User s Manual

UM-AJV Abacus Junior Vet User s Manual UM-AJV-01-276 Abacus Junior Vet User s Manual REVISION-HISTORY Date Name Signature Issued 06/10/2009 Ildiko Losonczi Checked and approved 06/10/2009 Csaba Magyar Abacus Junior Vet Hematology Analyzer User

More information

A Bright Cytometer Easy to use

A Bright Cytometer Easy to use BriCyte E6 Flow Cytometer A Bright Cytometer Easy to use BriCyte E6 Flow Cytometer Flow cytometer is an essential tool to analyze cells, so it s used for diagnosis as well as research in laboratories worldwide.

More information

BD CellQuest Pro Acquisition Tutorial

BD CellQuest Pro Acquisition Tutorial BD CellQuest Pro Acquisition Tutorial Introduction This tutorial guides you through a CellQuest Pro Acquisition run like the one demonstrated in the CellQuest Pro Acquisition Movie on the BD FACStation

More information

RT-7600 Auto Hematology Analyzer User s Manual

RT-7600 Auto Hematology Analyzer User s Manual RT-7600 Auto Hematology Analyzer User s Manual Copyright: Rayto Life and Analytical Sciences Co., Ltd. Address: C&D/4F, 7 th Xinghua Industrial Bldg, Nanhai Rd, Nanshan, Shenzhen 518067, P.R. China Rev:

More information

5.7. Quick Guide to Fusion Settings

5.7. Quick Guide to Fusion Settings 5.7 Quick Guide to Fusion Settings Quick Guide to Fusion Settings Fusion 5.7 This publication may not be reproduced, in whole or in part, in any form or by any electronic, manual, or other method now known

More information

MicrosEmi CRP External Output Manual (English)

MicrosEmi CRP External Output Manual (English) MicrosEmi CRP External Output Manual (English) CODE:I2002276000 3200306471 GZ0000215455 HORIBA. Ltd. 2 Miyanohigashi, Kisshoin Minami-ku kyoto 601-8510 Japan EC REP HORIBA ABX S.A.S. Rue du Caducée - Parc

More information

Continuous Imaging Fluid Particle Analysis: A Primer

Continuous Imaging Fluid Particle Analysis: A Primer Continuous Imaging Fluid Particle Analysis: A Primer Lew Brown Fluid Imaging Technologies Edgecomb, ME Introduction: Many scientific endeavors involve the use of particulate matter suspended within a liquid.

More information

Spherotech, Inc Irma Lee Circle, Lake Forest, IL

Spherotech, Inc Irma Lee Circle, Lake Forest, IL New flow cytometers, with fluorescent channels from the UV to Far Red, and corresponding fluorescent conjugates are now available. As a result, we have developed the Ultra Rainbow Fluorescent Particles

More information

AUTOMATIC WHITE BLOOD CELL SEGMENTATION BASED ON IMAGE PROCESSING. Juma Al-Muhairy, Yousef Al-Assaf

AUTOMATIC WHITE BLOOD CELL SEGMENTATION BASED ON IMAGE PROCESSING. Juma Al-Muhairy, Yousef Al-Assaf AUTOMATIC WHITE BLOOD CELL SEGMETATIO BASED O IMAGE PROCESSIG Juma Al-Muhairy, Yousef Al-Assaf School of Engineering, American University of Sharjah juma.almuhairy@dwtc.com ; yassaf@ausharjah.edu Abstract:

More information

Servicemanual Release

Servicemanual Release Hemolyzer 5 Servicemanual Release 1.0.20 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com 1 agile - affordable

More information

Intensive Care Unit and Paediatric Intensive Care Unit Essential Toolbar Buttons

Intensive Care Unit and Paediatric Intensive Care Unit Essential Toolbar Buttons Intensive Care Unit and Paediatric Intensive Care Unit Essential Toolbar Buttons The following buttons are situated on the PowerChart Toolbar which are commonly used throughout the Digital Release. Care

More information

FACCalibur Users Guide

FACCalibur Users Guide FACCalibur Users Guide FACSCalibur Start Up Procedure If the Instrument is OFF: 1. Check the sheath and waste tanks. Open the fluidics drawer (front of instrument) and check the levels of sheath fluid

More information

POWER EXPRESS CLINICAL AUTOMATION SOLUTION

POWER EXPRESS CLINICAL AUTOMATION SOLUTION Power Express POWER EXPRESS CLINICAL AUTOMATION SOLUTION INTRODUCTION Power Express is a connected clinical automation solution that provides industry-leading capacity and scalability with custom-tailored

More information

Recording Vital Signs and Test Results in Med-Center

Recording Vital Signs and Test Results in Med-Center Recording Vital Signs and Test Results in Med-Center Introduction This technical note discusses Med-Center s ability to record and plot lab test results or patient vital signs. This capability is a new

More information

LEUKEMIA PREDICTION USING RANDOM FOREST ALGORITHM

LEUKEMIA PREDICTION USING RANDOM FOREST ALGORITHM International Journal of Computer Science Engineering and Information Technology Research (IJCSEITR) ISSN (P): 2249-6831; ISSN (E): 2249-7943 Vol. 8, Issue 3, Aug 2018, 1-8 TJPRC Pvt. Ltd. LEUKEMIA PREDICTION

More information

CellaVision. Ola Andersson Peter Wilson. Siemens Belgium

CellaVision. Ola Andersson Peter Wilson. Siemens Belgium CellaVision Ola Andersson Peter Wilson Siemens Belgium CellaVision in short Headquarters in Lund, Sweden Around 80 employees globally Market support offices in the Nordic countries, the US, Canada, Japan,

More information

Clinical data acceptance testing procedure

Clinical data acceptance testing procedure Sunil Gupta With the recent news from FDA to push tighter safety reviews due to increased patient deaths caused by Viox, pharmaceutical companies need to develop systems for early detection of safety and

More information

FACSAria Fusion SORP QUICK REFERENCE GUIDE

FACSAria Fusion SORP QUICK REFERENCE GUIDE FACSAria Fusion SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Admin Password: BDIS 2. Ensure the flow cell access door is open. You will want to

More information

scil Technical Support

scil Technical Support Vet ABC Hematology Analyzer Calibration ** Before Calibration is performed run a concentrated cleaning and make sure your Photometer is within range. After both are completed run a Startup by pressing

More information

Addendum. COULTER GEN S System. PN C (May 1999) COULTER CORPORATION. A Beckman Coulter Company Miami, Florida USA GEN S

Addendum. COULTER GEN S System. PN C (May 1999) COULTER CORPORATION. A Beckman Coulter Company Miami, Florida USA GEN S TM TURBO RESET R POWER COULTER GEN S System Addendum TM * SYSTEM RUN * 05/03/95 0000 COPYRIGHT 1989-1995 COULTER CORPORATION STATUS : READY ALERT: BP CBC DIFF RETICS MAIN GEN S PN 4237411 C (May 1999)

More information

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune Cytometric Software version 1.2 ( Attune Software

More information

Quick Instruction Guide for Operating the scil Vet abc Plus

Quick Instruction Guide for Operating the scil Vet abc Plus Quick Instruction Guide for Operating the scil Vet abc Plus Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education Table of Contents Start Up Cycle... pg. 2 Reagents....pg.2-3 User Profiles......pg.4-5

More information

Hematology Analyzer. Serial Communication Protocol. 1.7 release

Hematology Analyzer. Serial Communication Protocol. 1.7 release Abacus Arcus Hematology Analyzer Serial Communication Protocol 1.7 release DIATRON Messtechnik Ges.m.b.H. A-1141 Wien, Ameisgasse 49-51/2. AUSTRIA Tel.: (431) 914-85-00, 911-38-48 Fax: 914-85-07-15 Web:

More information

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34)

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34) WORLDCLASS GLOBAL SUPPORT AUSTRALIA (61) 2 9844 6000 GERMANY (49) 2151 333 625 MEXICO (52) 5 559 1635 SWEDEN (46) 8 564 85900 CANADA (1) 905 819 1234 HONG KONG (852) 2814 7431 NETHERLANDS (31) 2972 30630

More information

Haematology/Blood Transfusion. Uncertainty of Measurement values. Haemoglobin g/l / g/l

Haematology/Blood Transfusion. Uncertainty of Measurement values. Haemoglobin g/l / g/l Haematology/Blood Transfusion Uncertainty of Measurement values Full Blood Count WBC

More information

Hemolyzer. 5 NG (closed mode) User Manual. Version 1.35

Hemolyzer. 5 NG (closed mode) User Manual. Version 1.35 Hemolyzer 5 NG (closed mode) User Manual Version 1.35 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com agile -

More information

Acute Lymphocytic Leukemia Detection from Blood Microscopic Images

Acute Lymphocytic Leukemia Detection from Blood Microscopic Images Acute Lymphocytic Leukemia Detection from Blood Microscopic Images Sulaja Sanal M. Tech student, Department of CSE. Sree Budhha College of Engineering for Women Elavumthitta, India Lashma. K Asst. Prof.,

More information

APPLICATION INFORMATION

APPLICATION INFORMATION A-1994A APPLICATION INFORMATION Particle Characterization USING LASER DIFFRACTION ANALYSIS IN PIGMENT SIZING Introduction Pigments and paints are an important class of industrial materials. They play an

More information

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION.

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. KALUZA C ANALYSIS SOFTWARE Kaluza C Flow Cytometry Analysis Software is built upon our successful Kaluza Analysis research use platform.

More information

Insight Program Modification

Insight Program Modification Document Number 61-1075 11/2006 Insight Program Modification Attention: Hematology Laboratory Director Analyzer Operators for Sysmex XE-Series, XT-Series and SE-Series Introduction The Insight Interlaboratory

More information

How to Use the Lab and Pathology Portlet

How to Use the Lab and Pathology Portlet The Lab and Pathology Results portlet displays consolidated diagnostic laboratory tests from Ontario Laboratories Information System (OLIS) for patients with an Ontario Health Number. 1. In the Patient

More information

UNIVERSITY OF CALGARY. Chronic Lymphocytic Leukaemia Cell Classification. Emad Amin Mohammed A THESIS SUBMITTED TO THE FACULTY OF GRADUATE STUDIES

UNIVERSITY OF CALGARY. Chronic Lymphocytic Leukaemia Cell Classification. Emad Amin Mohammed A THESIS SUBMITTED TO THE FACULTY OF GRADUATE STUDIES UNIVERSITY OF CALGARY Clinical Decision Support System with Adaptive Software Framework for Chronic Lymphocytic Leukaemia Cell Classification by Emad Amin Mohammed A THESIS SUBMITTED TO THE FACULTY OF

More information

HealthInfoNet CLINICAL PORTAL USER REFERENCE GUIDE. Revised: Page 1 of 24

HealthInfoNet CLINICAL PORTAL USER REFERENCE GUIDE. Revised: Page 1 of 24 HealthInfoNet CLINICAL PORTAL USER REFERENCE GUIDE Revised: 6.3.2015 Page 1 of 24 HealthInfoNet User Reference Guide INSIDE: Accessing HealthInfoNet (HIN) 3-5 Clinical Portal 6-11 Notifications and Worklists

More information

A Comparative Study of White Blood cells Segmentation using Otsu Threshold and Watershed Transformation

A Comparative Study of White Blood cells Segmentation using Otsu Threshold and Watershed Transformation ` VOLUME 3 ISSUE 3 A Comparative Study of White Blood cells Segmentation using Otsu Threshold and Watershed Transformation Noorhan M Sobhy, Nancy M Salem and Mohamed El Dosoky Department of Biomedical

More information

Requirements Definition Document (RDD)

Requirements Definition Document (RDD) Requirements Definition Document (RDD) Revision History Date Version Created By/Revised By: Reason for Revision: 20 Jan 2012 1.0 Tauhid Siddiqui 27 Jan 2012 1.0 Tauhid Siddiqui Incorporating changes suggested

More information

ServiceManual. COULTER STKSAnalyzer COULTER STKSAnalyzerwithReticulocyteAnalysis COULTER STKSAnalyzerwithCD4andCD8Lymphocyte Analysis

ServiceManual. COULTER STKSAnalyzer COULTER STKSAnalyzerwithReticulocyteAnalysis COULTER STKSAnalyzerwithCD4andCD8Lymphocyte Analysis COULTER COULTER STKSAnalyzer COULTER STKSAnalyzerwithReticulocyteAnalysis COULTER STKSAnalyzerwithCD4andCD8Lymphocyte Analysis ServiceManual STKS PN4235915J (April 1996) COULTERCORPORATION Miami,Florida33196

More information

Edge Detection based Classification of Leukocytes in Blood

Edge Detection based Classification of Leukocytes in Blood Available Online at www.ijcsmc.com International Journal of Computer Science and Mobile Computing A Monthly Journal of Computer Science and Information Technology ISSN 2320 088X IMPACT FACTOR: 5.258 IJCSMC,

More information

BLOOD SMEAR ANALYSIS FOR ACUTE LEUKEMIA DETECTION-MACHINE LEARNING APPROACH

BLOOD SMEAR ANALYSIS FOR ACUTE LEUKEMIA DETECTION-MACHINE LEARNING APPROACH BLOOD SMEAR ANALYSIS FOR ACUTE LEUKEMIA DETECTION-MACHINE LEARNING APPROACH BIJI G Electrical Department, Govt Engineering College, Barton Hill, Thiruvananthapuram, Abstract Whenever the normal functioning

More information

CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680

CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Microgenics Corporation Part of Thermo Fisher Scientific CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Catalog No. 100088, 100097, 1730916 Intended for the Qualitative and Semiquantitative

More information

Near UV Laser System Performance on the CytoFLEX S

Near UV Laser System Performance on the CytoFLEX S Near UV Laser System Performance on the CytoFLEX S APPLICATION NOTE Authors: Jeffrey Cobb James Tung Affiliation: Life Science, Beckman Coulter, Inc., Miami, FL, United States Introduction Material and

More information

How To Switch Primary And Secondary Axis In

How To Switch Primary And Secondary Axis In How To Switch Primary And Secondary Axis In Excel 2007 How-to Close the Gaps Between Chart Series in an Excel Stacked Clustered Then change the Series Options Plot Series On to Secondary Axis: image. You

More information

Cerner 2015 Upgrade. Tagging. Tagging via the Table of Contents

Cerner 2015 Upgrade. Tagging. Tagging via the Table of Contents Cerner 2015 Upgrade This document will demonstrate how to utilize the tagging feature, favorite a note template and carbon copy/forward to a provider a progress note as part of the Cerner 2015 upgrade.

More information

A&S 320: Mathematical Modeling in Biology

A&S 320: Mathematical Modeling in Biology A&S 320: Mathematical Modeling in Biology David Murrugarra Department of Mathematics, University of Kentucky http://www.ms.uky.edu/~dmu228/as320/ These slides were modified from Matthew Macauley s lecture

More information

Hemolyzer 3 NG. User Manual. Version 1.35

Hemolyzer 3 NG. User Manual. Version 1.35 Hemolyzer 3 NG Version 1.35 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com agile - affordable - accurate Contents

More information

DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800

DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Microgenics Corporation Part of Thermo Fisher Scientific DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Catalog No. 100248, 100249, 10015632 The DRI Oxycodone Enzyme Immunoassay is intended

More information

BD CellQuest Pro Software Acquisition Tutorial

BD CellQuest Pro Software Acquisition Tutorial BD CellQuest Pro Software Acquisition Tutorial This tutorial guides you through a typical acquisition using BD CellQuest Pro software. If you are already familiar with previous versions of BD CellQuest

More information

Addendum to S.U.N. for version 3.00

Addendum to S.U.N. for version 3.00 Filename: SUN for DTS v3.00 Addendum.doc Doct. Version No: 1 Date: August 2003 Author: M.T.Connah Product Software suite Product Zetasizer Nano series PartNo.-Issue PSS0012-01 PartNo./Version PSW0085/3.00

More information

CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680

CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 Catalog No. 100084, 100093, 1661213, 10017365 Microgenics Corporation Part of Thermo Fisher Scientific Intended for the Qualitative and Semiquantitative

More information

Training Guide. SurgiNet Anesthesia. What's Inside this Guide:

Training Guide. SurgiNet Anesthesia. What's Inside this Guide: What's Inside this Guide: Table of Contents Tips and Tricks Getting Started Select a Case Starting a Macro Medications Intakes and Outputs Monitored Values Actions Personnel Finalize a Record Training

More information

Valley Irrigation Run Time App Version 1.1

Valley Irrigation Run Time App Version 1.1 Valley Irrigation Run Time App Version. User Guide 09805_0 07 Valmont Industries, Inc., Valley, NE 6806 USA. All rights reserved. www.valleyirrigation.com Table of Contents Valley Irrigation Run Time App

More information