Beckman Coulter Professional Development 2014 Beckman Coulter, Inc. 1of 50
|
|
- Daniel Atkins
- 6 years ago
- Views:
Transcription
1 THE BECKMAN COULTER logo, COULTER, DxH, TruColor, and UniCel are trademarks of Beckman Coulter, Inc; COULTER and UniCel are registered in the USPTO. 1of 50
2 Objectives Flags Codes Messages CBC Parameters Cellular Interference Differential Parameters NRBC Parameters Retic Parameters 2of 50
3 Flags * These Flags are also associated with System Messages. See System Messages in HELP for more information. 3of 50
4 Codes 4of 50
5 Messages Messages Results related: Suspect: messages are generated by internal algorithms to convey that a clinical condition may exist with a specimen based on an abnormal cell population or distribution. System: messages indicate an event that may affect the operation of a system, requires operator notification and or entry into a History Log. Most accompanied by an R (review) flag Some are accompanied by N or P flags Definitive: defined by the Operator 5of 50
6 Messages Exception or System Status Messages Exception: anything with an exception may or may not be released depending on your lab s release rules criteria. An exception is the default test order. System Status: an event that may affect system operation. Accompanied by operator notification and entry into log. 6of 50
7 Examples 7of 50
8 CBC Parameters 8of 50
9 Data Fusion 9of 50
10 Cellular Interference System message Cellular Inter WBC & associated parameters, or TNC, flagged with R The results are only flagged if we are uncertain of the correction, or can t correct (not just because a correction occurred). Suspect message Cellular Inter WBC & associated parameters, or TNC, flagged with R For CBC or CBC/Retic panels only, when NRBC are detected but not reported. 10 of 50
11 Red Cell Messages Suspect message Dimorphic Reds Data pattern consistent with the presence of multiple red cell populations Suspect message Red Cell Agglut Data pattern consistent with the presence of agglutinated red cells 11 of 50
12 RBC Fragments/Microcytes Suspect message RBC Frag/Micro Pattern observed consistent with the presence of RBC fragments and/or microcytic red cells. 12 of 50
13 Giant Platelets Suspect message Giant Platelet May be accompanied by System message specific to platelet results Giant Platelet data pattern observed 13 of 50
14 Platelet Clumps System message Platelet Clumps PLT & associated parameters flagged with R Clumped platelet data pattern observed 14 of 50
15 Platelet Messages System message PLT Inter: Debris PLT & associated parameters flagged with R PLT requires review due to the possible presence of an interference with small platelets System message RBC-PLT Overlap PLT & associated parameters flagged with R PLT histogram shows a possible interference with larger platelets 15 of 50
16 WBC Interference from HGB System message WBC Inter: HGB HGB & associated parameters flagged with R HGB may not be adequately corrected for WBC interference 16 of 50
17 Differential Parameters 17 of 50
18 One Cell at a Time... WBCs are hydrodynamically focused FLOW CELL S H E A T H -F L U ID IN SAMPLE DILUTION SENSING AREA SHEATH FLUID SHEATH-FLUID IN SAMPLE IN 18 of 50
19 Flow Cytometric Digital Morphology Multiple angles of light scatter, captures 10X more data than previously possible AL2 (axial light loss) LALS (lower angle LS) LMALS (lower med angle LS) UMALS (upper med angle LS) MALS (median angle LS) 19 of 50
20 Flow Cytometric Digital Morphology 20 of 50
21 Differential Parameters MONO NEUTS EOS LYMPH BASO 21 of 50
22 Abnormal Cell Distribution MO Blasts 2 NE Blasts 3 Immature Granulocytes 4 Band Neutrophils 5 LY Blasts 6 Variant Lymphocytes 7 Small Lymps / Low Opacity 8 Non-White Cells 8 22 of 50
23 LY Blast 5PD1 5PD2 Normal 5PD1 Suspect message LY Blast Blasts suspected in the LY area of the dataplot Data pattern consistent with possible presence of very immature cells 23 of 50
24 MO Blast 5PD1 5PD2 Normal 5PD1 Suspect message MO Blast Blasts suspected in the MO area of the dataplot Data pattern consistent with possible presence of very immature cells 24 of 50
25 NE Blast 5PD1 5PD2 Normal 5PD1 Suspect message NE Blast Blasts suspected in the NE area of the dataplot Data pattern consistent with possible presence of very immature cells 25 of 50
26 Immature Granulocytes 5PD1 5PD2 Normal 5PD1 Suspect message Imm Grans [Metamyelocytes, myelocytes &/or promyelocytes] or [myelocytes & promyelocytes] Variable sensitivity with default set at high 26 of 50
27 Left Shift 5PD1 5PD2 Normal 5PD1 Suspect message Left Shift Metamyelocytes, without more immature granulocytes Variable sensitivity with default at high Can be disabled 27 of 50
28 Variant LY 5PD1 5PD2 Normal 5PD1 Suspect message Variant LY Variant (viral), atypical or abnormal LY suspected Variable sensitivity with default at high 28 of 50
29 Abnormal Diff Pattern 5PD1 5PD2 Normal 5PD1 System message Abn Diff Pattern Results do not match any known template All Diff results accompanied by R flag 29 of 50
30 NRBC 5PD1 5PD2 Normal 5PD1 Suspect message NRBC NRBC suspected in the signature position of the dataplot Only in condition where the NRBC module is disabled and the panel includes a Diff 30 of 50
31 Aged Sample 5PD1 5PD2 Normal 5PD1 System message Aged Sample All Diff results accompanied by R flag The results are only flagged if we are unable to give a correct differential, not just because aging is present. 31 of 50
32 Excessive Debris 5PD1 5PD2 System message Excessive Debris: D All Diff results accompanied by R flag 32 of 50
33 NE-EO Overlap 5PD1 5PD2 System message NE-EO Overlap All Diff results flagged with R Population shift observed (NE and EO not in correct spatial location) 33 of 50
34 MO-NE Overlap 5PD1 5PD2 System message MO-NE Overlap All Diff results flagged with R Population shift observed (MO and NE not in correct spatial location) 34 of 50
35 Low Events: D 5PD1 5PD2 System message Low Events: D Not enough events available for differential 35 of 50
36 High Opacity Events 5PD1 5PD2 System message High OP Events All Diff results accompanied by R flag Interference in Opacity that has been observed with bone marrow samples or specimens with platelet clumps. 36 of 50
37 Low RMALS Events 5PD1 5PD2 System message Low RMALS Events All Diff results flagged with R RMALS mode value is too low 37 of 50
38 NRBC Parameters PLT/DEBRIS WBC NRBC 38 of 50
39 Abnormal NRBC Pattern NRBC1 NRBC2 System message Abn NRBC Pattern NRBC & associated parameters flagged with R Fits no known pattern Normal nrbc 39 of 50
40 NRBC-LY Overlap System message NRBC-LY Overlap NRBC & associated parameters flagged with R Couldn t separate NRBC from small LY during analysis Normal nrbc NRBC1 NRBC2 40 of 50
41 NRBC Interference System message NRBC Inter NRBC & associated parameters flagged with R Significant amount of interference in NRBC regions that are not NRBC Normal nrbc NRBC1 NRBC2 41 of 50
42 Miscellaneous NRBC Messages Detected by Hardware, not algorithm Flow Cell Clog: N System Event: N 42 of 50
43 Reticulocyte Parameters WBC S MATURE RBC S RETICS PLT/DEBRIS 43 of 50
44 Abnormal Hemoglobin Normal Retic Suspect message Abn Hemoglobin Others category = green (~ platelets) & orange (not cleared) particles. Indicates a possible clearing problem in the presence of abnormal hemoglobin 44 of 50
45 Sickled Cells Suspect message Sickled Cells Data pattern consistent with sickled cells Normal Retic 45 of 50
46 Retic System Messages System message RET-RBC Overlap RET & associated parameters flagged with R. Unclear separation of retics & mature red cells. System message RET Inter: PLT RET & associated parameters flagged with R. The platelet population may have interfered with the RET. 46 of 50
47 Nucleated Cells System message Nucleated Cells RET & associated parameters flagged with R NRBC or small WBC (especially small LY as in CLL) are visible in the dataplot (blue) and may have interfered with RET measurement 47 of 50
48 Flow Cell Clog System message Flow Cell Clog: R RET and associated parameters flagged with R Hardware detected a flow cell clog during analysis It is possible to have a flow cell clog that is severe enough to inhibit data [:::::]. 48 of 50
49 System Event During Retic Examples include (but are not limited to): Laser Offset Voltage failure Temperature Out of Range System message System Event: R RET & associated parameters flagged with R Hardware parameters were out of limit for an item that could affect RET analysis (e.g. voltage, temperature, pressure). 49 of 50
50 THE END! 50 of 50
Unicel DxH 600 System
SETUP MODULES Setup Unicel DxH 600 System Troubleshooting System Overview Additional Topics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU).
More informationIntelligent Automation
Intelligent Automation Using Automation, Middleware and Digital Imaging to Transform Hematology Workflow and Outcomes UTMB Major Academic Health Science Center 6 hospitals Level 1 trauma center 24-room
More informationProcessing haematological data on a network environment
Malaysian J Pathol 1995; 17(2): 77-81 Processing haematological data on a network environment ZAINAL AG DMLT* and SK CHEONG FRCP,FRCPA Department of Pathology and Medicine*, Faculty of Medicine, Universiti
More informationADVIA 360, ADVIA 560, and ADVIA 560 AL Systems
Siemens Solutions for Hematology ADVIA 360, ADVIA 560, and ADVIA 560 AL Systems Answers for life. The ADVIA Hematology Family Siemens can now offer a total solution with the ADVIA 360, ADVIA 560, ADVIA
More informationLab ID 406. Your Parameters. Institution: Analyte. WBC Siemens Advia 120 Siemens 10 9 /L. RBC Siemens Advia 120 Siemens /L
Your Parameters Institution: Analyzer Reagent Cat N Reagent Manufacturer Method Group Calibrator Cat n Calibrator Cal Lot # Unit WBC Siemens Advia 12 Siemens 1 9 /L RBC Siemens Advia 12 Siemens 1 12 /L
More informationSysmex WAM v4.1 Rule Overview Workshop
Sysmex WAM v4.1 Rule Overview Workshop Intermountain Health Care User Group Meeting April 22, 2014 Agenda Rule Overview Common Rule Types Rule Creation Procedures Intermountain Health Rule Examples 1 Sysmex
More informationCELL-DYN Sapphire TM Interface Set-up Procedure for Accelerator DM Application Software Version 1.0
Abbott Accelerator TM Decision Manager TM Page 1 of 20 CELL-DYN Sapphire TM Interface Set-up Procedure for Accelerator DM Application Software Version 1.0 Purpose Prepare the Accelerator Decision Manager
More informationUniCel DxH 600 Coulter Cellular Analysis System Training Modules
UniCel DxH 600 Coulter Cellular Analysis System Training Modules This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions
More informationDecember 2002 CAP TODAY / 37
December 2002 CAP TODAY / 37 Part 1 of 9 Abbott Diagstics Hematology Business Unit 5440 Patrick Henry Dr. Santa Clara, CA 95054 800-933-5535 www.abbott.com Cell-Dyn 3200 1997/1997 >700/>1,500/$16 standard
More informationCOULTER STKS Analyzer with Reticulocyte Analysis. Operator s Guide. PN B (March 1995) COULTER CORPORATION Miami, Florida 33196
COULTER STKS Analyzer with Reticulocyte Analysis Operator s Guide PN 4237188B (March 1995) COULTER CORPORATION Miami, Florida 33196 READ ALL PRODUCT MANUALS AND CONSULT WITH COULTER-TRAINED PERSONNEL BEFORE
More informationNo./DMER/Tender Notice/Equip.Pur/16-17/Corri.(04)/7M Date :- 28/07/2016
No./DMER/Tender Notice/Equip.Pur/16-17/Corri.(04)/7M Date :- 28/07/2016 E-Tender Notice CORRIGENDUM REGARDING SPECIFICATIONS FOR 1. EQ-C-74/16-17 Automated 5 part Deferential Cell Counter 2. EQ-C-93/16-17
More informationThe right PLT count when it matters. 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe
The right PLT count when it matters 20/4/2016 Sysmex Användarmöte Sverige Pieter Steenhuis Sysmex Europe Agenda 01 02 03 Introduction Identify samples with unreliable PLT counts due to platelet clumps
More informationBoule Medical AB CA620-CellGuard Page Usermanual V3.7
1 File : 620-CellGuard -30-370 Software version V3.7x Article number of this manual : 1504038 Table of contents 1 Identification of hazards & interpretation of results...5 1.1 Interpretation of results...6
More informationELECTIVES MODULES. Implement. Electives. Setup. Troubleshooting. Basics
ELECTIVES MODULES Implement Electives Setup Troubleshooting Basics This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions
More informationBC Auto Hematology Analyzer. Pleasant Experience in Hematology Testing
BC-3600 Auto Hematology Analyzer Pleasant Experience in Hematology Testing BC-3600 Auto Hematology Analyzer Labs today are facing a multitude of challenges including limited laboratory budgets, increasing
More informationUniCel DxH 800 Coulter Cellular Analysis System Training Modules
Training Modules This document is not intended to replace the information in your Instrument Instructions for Use Manual (IFU). Information in the Instructions for Use Manual supersedes information in
More informationNext Generation Hematology Analyzer. BeneSphera H33s. Minimum Size, Maximum Capability
Next Generation Hematology Analyzer BeneSphera H33s Minimum Size, Maximum Capability H33s BeneSphera BeneSphera H33s Next Generation Hematology Analyzer What a 3-part should be Avantor s new line of hematology
More informationRAA040AEN OUTPUT FORMATS PENTRA 80 / XL80
RAA040AEN OUTPUT FORMATS PENTRA 80 / XL80 Table of Contents -> Introduction page 3 -> Connection, page 4 -> ASTM Format page 6 -> ABX Format page 22 RAA040AEN HORIBA ABX PROPERTY 2 Introduction ASTM Format
More informationOutput format for haematology analyzers Pentra 60/Pentra 60C+/Pentra 80/Pentra 80 XL/Pentra 120 Micros/Micros 60/Micros CRP
HORIBAABX Montpellier Output format for haematology analyzers Pentra 60/Pentra 60C+/Pentra 80/Pentra 80 XL/Pentra 120 Micros/Micros 60/Micros CRP RAA024HA Chapter 4: ABX Format ASTM Format is recommended
More informationHA-86 (89) Auto Hematology Analyzer User s Manual
HA-86 (89) Auto Hematology Analyzer User s Manual 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.7.17 HA-86 (89) User's Manual How to use this Manual Thank you for
More informationUsermanual Release
Usermanual Release 1.2.21 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com 1 agile - affordable - accurate Usermanual
More informationKit Contents FH9-06 FH9-10 BCP-11 BCP-20 CD-ROM. Important: Before You Begin. New for this Mailing
Comprehensive Hematology Survey Automated Differential FH9 FH9P 2FH9 FH9-B 2014 Kit Instructions CAP 2014 Table of Contents Kit Contents Kit Contents... 1 Important: Before You Begin... 1 Detailed Testing
More informationINDEX TECHNICAL SERVICE BULLETIN
CELL-DYN 3200/SL (109) Index ABBOTT ADD INDEX TECHNICAL SERVICE BULLETIN PRODUCT: CELL-DYN 3200/SL (109) DATE: 29-JUL-98 TSB # IMPLEMENTATION SUBJECT EFFECTIVITY DATE 109-010 I - See TSB CELL-DYN 3200/SL
More informationAutomated Red Blood Cell Differential Analysis on a Multi-Angle Light Scatter/Fluorescence Hematology Analyzer
Cytometry Part B (Clinical Cytometry) 56B:43 54 (2003) Automated Red Blood Cell Differential Analysis on a Multi-Angle Light Scatter/Fluorescence Hematology Analyzer Young Ran Kim, 1 * Ronny van t Oever,
More informationContents. Preface Safety Instruction Specifications Measuring Principles Parameter Flags... 33
User s Manual Medonic CA620 + MPA + AD Medonic CA620 + MPA Medonic CA620 Medonic CA530 + MPA + AD Medonic CA530 + MPA Medonic CA530 Medonic CA620-CellGuard + MPA + AD Medonic CA620-CellGuard + MPA Contents
More informationOUTPUT FORMATS. Pentra DX / DF Nexus RAA048AEN
OUTPUT FORMATS Pentra DX / DF Nexus RAA048AEN Revisions Table of contents -> Introduction, page 3 Table 1: Revisions Index Software revision Chapter, page Date A V1.2.0 All 15/08/2013 -> Physical connection
More informationDifftote 12 A sophisticated microprocessor based counter for the counting of Leucocyte cells when performing the Differential count.
Difftote 12 A sophisticated microprocessor based counter for the counting of Leucocyte cells when performing the Differential count. Operation Manual Index page 22 1 INTRODUCTION The Difftote 12 is a sophisticated
More informationFast Facts. for Operating the scil Vet abc Plus. Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education
Fast Facts for Operating the scil Vet abc Plus Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education SCIL Vet ABC Plus Fast Facts Table of Contents Start Up Cycle pg. 2 Reagents Status
More informationWorld-class veterinary hematology system
World-class veterinary hematology system New Exigo H400 CBC from one drop of blood Easy-to-use interface 12 pre-installed animal profiles Robust and reliable Exigo when quality counts! Exigo H400 is a
More informationTotal WBC count and differential WBC count HemoCue WBC DIFF system
TLM_PRO_029 and Version No. 001 Page 1 of 6 Department: Clinical Sciences Unit: Tropical Laboratory Medicine Total WBC count and differential WBC count HemoCue WBC DIFF system Project/study: Not applicable
More informationAPS (Automatic Population Separator)
Infinicyt provides a list of very powerful tools for research and diagnosis of haematological diseases through flow cytometry data analysis. The features that most distinguish Infinicyt software from other
More informationRemisol Advance for Hematology Customers
Remisol Advance for Hematology Customers This Training Guide belongs to: Rev. C (June 2015) i of iv Beckman Coulter Professional Development WARNINGS AND PRECAUTIONS This training guide is not intended
More informationParameter / Paramètre. (1) Assay values provided by EUROCELL Diagnostics, France. Valeurs fournies par EUROCELL Diagnostics, France.
CBC- Plus IBRATION VALUES AND ACCEPTABLE RANGES VALEURS DE IBRATION ET LIMITES 1 s : ABX (1) ABX WBC/GB 10 3 /µl & 10 9 /L 9,3 9,1-9,5 Pentra 60 Series RBC/GR 10 6 /µl & 10 12 /L 4,81 4,73-4,89 Pentra
More informationBD FACSMelody Cell Sorter Quick Reference Guide
BD FACSMelody Cell Sorter Quick Reference Guide This guide contains instructions for using the BD FACSMelody cell sorter with BD FACSChorus software version. and later. Workflow Overview The following
More informationHematology Program (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) Cycle 11: March 2016 February Sample No: 1 Sample Date: 14 Apr 16
Exceptions (BC90A/BC90B/BC90C/BC90D/CS90A/CS90B/CS90C/CS90D) : March 206 February 207 None at this time. Legend: No Warnings Missing Result Late Results < < > * Amended Result (per participant s request)
More informationDate Name Signature Issued 06-MAY-2011 Csaba Magyar Checked and approved 17-MAY-2011 Gábor Farkas
Revision history OM-ACS30-01-1110 Rev. Date Edited by Sections affected Approved by 1.0 2009-06-02 Arpad Gyetvai Initial revision Csaba Magyar 1.1 2010-03-25 Gabor Farkas First review, new GUI screenshots
More informationBoule Page 1/36 Service manual BM800 Doc No Section 9 Version 02
Page 1/36 Section overview 9. General (V02)... 2 9.1 Serial output (hardware)... 2 9.2 Serial output format... 3 9.3 XML serial output format description... 8 9.4 Upgrading software... 35 Page 2/36 9.
More informationOM-A Revision history Rev. Date Edited by Sections affected Approved by
OM-A380-01-115 Revision history Rev. Date Edited by Sections affected Approved by 1.0 2010.05.14 Gabor Farkas Initial revision 1.1 2010.07.27. Gabor Farkas Reagent Lock System added, Profile settings added,
More information0.1-4 mg/dl or μmol/l or mmol/l 152 Upper limit of normal for your institution creatinine
s Recipient Baseline Data (Form 2000) 141 AST (SGOT) 0-200 U/L or 0-3.2 μkat/l 144 Total serum bilirubin 0.2-15 mg/dl or 3.5-263 μmol/l 146 Upper limit of normal for your institution - bilirubin 0.2-2.5
More informationOutput format. 1. ABX format principles PIN assignments ARGOS format principles ASTM Specifications...
Output format 1. ABX format principles...6-2 1.1. Message structure...6-2 1.2. Details about the structure... 6-2 1.3. Identifier list and their formats...6-3 1.4. Pathology...6-5 1.5. Histograms and matrix...6-8
More informationHematology Analyzer. User s Manual. Revision 2.17
Abacus junior 5 Hematology Analyzer User s Manual Revision 2.17 TABLE OF CONTENTS 1 INTRODUCTION... 1-1 1.1 Intended Use... 1-1 1.2 General Description... 1-1 1.2.1 The Instrument... 1-1 1.2.2 Patient
More informationCellaVision Proficiency Software
CellaVision Proficiency USER S MANUAL 2.3 CellaVision Proficiency Preface CellaVision is a trademark of CellaVision AB. All other trademarks used in this document are property of their respective owners.
More informationCELL-DYN 1800 Field Service Training Workbook
CELL-DYN 1800 Field Service Training Workbook Abbott Laboratories Abbott Park, IL. 60064 2003 Abbott Laboratories 96919-101 04/09/03 Proprietary Statement Copyright 2003, Abbott Laboratories Diagnostics
More informationMedonic M-series M32 Innovation built on total quality
Medonic M-series M32 Innovation built on total quality FOR TODAY S HEMATOLOGY LABS Full CBC from one drop of blood Maintenance-free shear valve Unique walk-away Autoloader Make way for Medonic! Packed
More informationUser Definable Settings
User Definable Settings Section 1: User Definable Print Format Settings...1 Section 2: Parameter Unit Selection...7 Section 3: Setup Menu 2...8 Section 4: Setup Menu 3...11 Section 1: User Definable Print
More informationResveratrol mitigates lipopolysaccharide-mediated acute. inflammation in rats by inhibiting the TLR4/NF-κBp65/MAPKs.
Resveratrol mitigates lipopolysaccharide-mediated acute inflammation in rats by inhibiting the TLR4/NF-κBp65/MAPKs signaling cascade Guangxi Wang a,1, Zhiqiang Hu b,1, Qiuting Fu a,1, Xu Song a,1, Qiankun
More informationINTERFACE SPECIFICATION
INTERFACE SPECIFICATION CELL-DYN 1800 SYSTEM LIST NO. 07H79-01 REVISION A ABBOTT DIAGNOSTICS DIVISION Abbott Laboratories Abbott Park, IL 60064, USA INTERFACE SPECIFICATION CELL-DYN 1800 SYSTEM Abbott
More informationAbacus plus. Hematology Analyzer. User s Manual release
Abacus plus Hematology Analyzer User s Manual 1.00 release Revision history: Revision Section Modification By At 0.03 All Parallel printer version Support team 19.06.2006. 1.00 1, 7 USB printer version
More informationBlood Microscopic Image Analysis for Acute Leukemia Detection
I J C T A, 9(9), 2016, pp. 3731-3735 International Science Press Blood Microscopic Image Analysis for Acute Leukemia Detection V. Renuga, J. Sivaraman, S. Vinuraj Kumar, S. Sathish, P. Padmapriya and R.
More informationCommunication Links Between the Data Manager and a Host Computer
T ADVIA 120 Hematology System Communication Links Between the Data Manager and a Host Computer Publication No. TN9-7865-02 / June 2000 Publication Change Record Publication Number Date TN9-7865-00 December
More informationUM-AJV Abacus Junior Vet User s Manual
UM-AJV-01-276 Abacus Junior Vet User s Manual REVISION-HISTORY Date Name Signature Issued 06/10/2009 Ildiko Losonczi Checked and approved 06/10/2009 Csaba Magyar Abacus Junior Vet Hematology Analyzer User
More informationA Bright Cytometer Easy to use
BriCyte E6 Flow Cytometer A Bright Cytometer Easy to use BriCyte E6 Flow Cytometer Flow cytometer is an essential tool to analyze cells, so it s used for diagnosis as well as research in laboratories worldwide.
More informationBD CellQuest Pro Acquisition Tutorial
BD CellQuest Pro Acquisition Tutorial Introduction This tutorial guides you through a CellQuest Pro Acquisition run like the one demonstrated in the CellQuest Pro Acquisition Movie on the BD FACStation
More informationRT-7600 Auto Hematology Analyzer User s Manual
RT-7600 Auto Hematology Analyzer User s Manual Copyright: Rayto Life and Analytical Sciences Co., Ltd. Address: C&D/4F, 7 th Xinghua Industrial Bldg, Nanhai Rd, Nanshan, Shenzhen 518067, P.R. China Rev:
More information5.7. Quick Guide to Fusion Settings
5.7 Quick Guide to Fusion Settings Quick Guide to Fusion Settings Fusion 5.7 This publication may not be reproduced, in whole or in part, in any form or by any electronic, manual, or other method now known
More informationMicrosEmi CRP External Output Manual (English)
MicrosEmi CRP External Output Manual (English) CODE:I2002276000 3200306471 GZ0000215455 HORIBA. Ltd. 2 Miyanohigashi, Kisshoin Minami-ku kyoto 601-8510 Japan EC REP HORIBA ABX S.A.S. Rue du Caducée - Parc
More informationContinuous Imaging Fluid Particle Analysis: A Primer
Continuous Imaging Fluid Particle Analysis: A Primer Lew Brown Fluid Imaging Technologies Edgecomb, ME Introduction: Many scientific endeavors involve the use of particulate matter suspended within a liquid.
More informationSpherotech, Inc Irma Lee Circle, Lake Forest, IL
New flow cytometers, with fluorescent channels from the UV to Far Red, and corresponding fluorescent conjugates are now available. As a result, we have developed the Ultra Rainbow Fluorescent Particles
More informationAUTOMATIC WHITE BLOOD CELL SEGMENTATION BASED ON IMAGE PROCESSING. Juma Al-Muhairy, Yousef Al-Assaf
AUTOMATIC WHITE BLOOD CELL SEGMETATIO BASED O IMAGE PROCESSIG Juma Al-Muhairy, Yousef Al-Assaf School of Engineering, American University of Sharjah juma.almuhairy@dwtc.com ; yassaf@ausharjah.edu Abstract:
More informationServicemanual Release
Hemolyzer 5 Servicemanual Release 1.0.20 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com 1 agile - affordable
More informationIntensive Care Unit and Paediatric Intensive Care Unit Essential Toolbar Buttons
Intensive Care Unit and Paediatric Intensive Care Unit Essential Toolbar Buttons The following buttons are situated on the PowerChart Toolbar which are commonly used throughout the Digital Release. Care
More informationFACCalibur Users Guide
FACCalibur Users Guide FACSCalibur Start Up Procedure If the Instrument is OFF: 1. Check the sheath and waste tanks. Open the fluidics drawer (front of instrument) and check the levels of sheath fluid
More informationPOWER EXPRESS CLINICAL AUTOMATION SOLUTION
Power Express POWER EXPRESS CLINICAL AUTOMATION SOLUTION INTRODUCTION Power Express is a connected clinical automation solution that provides industry-leading capacity and scalability with custom-tailored
More informationRecording Vital Signs and Test Results in Med-Center
Recording Vital Signs and Test Results in Med-Center Introduction This technical note discusses Med-Center s ability to record and plot lab test results or patient vital signs. This capability is a new
More informationLEUKEMIA PREDICTION USING RANDOM FOREST ALGORITHM
International Journal of Computer Science Engineering and Information Technology Research (IJCSEITR) ISSN (P): 2249-6831; ISSN (E): 2249-7943 Vol. 8, Issue 3, Aug 2018, 1-8 TJPRC Pvt. Ltd. LEUKEMIA PREDICTION
More informationCellaVision. Ola Andersson Peter Wilson. Siemens Belgium
CellaVision Ola Andersson Peter Wilson Siemens Belgium CellaVision in short Headquarters in Lund, Sweden Around 80 employees globally Market support offices in the Nordic countries, the US, Canada, Japan,
More informationClinical data acceptance testing procedure
Sunil Gupta With the recent news from FDA to push tighter safety reviews due to increased patient deaths caused by Viox, pharmaceutical companies need to develop systems for early detection of safety and
More informationFACSAria Fusion SORP QUICK REFERENCE GUIDE
FACSAria Fusion SORP QUICK REFERENCE GUIDE INSTRUMENT: 1. The computer is left on at all times. Note: If not Username: Admin Password: BDIS 2. Ensure the flow cell access door is open. You will want to
More informationscil Technical Support
Vet ABC Hematology Analyzer Calibration ** Before Calibration is performed run a concentrated cleaning and make sure your Photometer is within range. After both are completed run a Startup by pressing
More informationAddendum. COULTER GEN S System. PN C (May 1999) COULTER CORPORATION. A Beckman Coulter Company Miami, Florida USA GEN S
TM TURBO RESET R POWER COULTER GEN S System Addendum TM * SYSTEM RUN * 05/03/95 0000 COPYRIGHT 1989-1995 COULTER CORPORATION STATUS : READY ALERT: BP CBC DIFF RETICS MAIN GEN S PN 4237411 C (May 1999)
More informationApplied Biosystems Attune Cytometric Software version 1.2 Release Notes
Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune Cytometric Software version 1.2 ( Attune Software
More informationQuick Instruction Guide for Operating the scil Vet abc Plus
Quick Instruction Guide for Operating the scil Vet abc Plus Hematology Chemistry Digital Radiography Ultrasound Orthopedics Education Table of Contents Start Up Cycle... pg. 2 Reagents....pg.2-3 User Profiles......pg.4-5
More informationHematology Analyzer. Serial Communication Protocol. 1.7 release
Abacus Arcus Hematology Analyzer Serial Communication Protocol 1.7 release DIATRON Messtechnik Ges.m.b.H. A-1141 Wien, Ameisgasse 49-51/2. AUSTRIA Tel.: (431) 914-85-00, 911-38-48 Fax: 914-85-07-15 Web:
More informationMEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34)
WORLDCLASS GLOBAL SUPPORT AUSTRALIA (61) 2 9844 6000 GERMANY (49) 2151 333 625 MEXICO (52) 5 559 1635 SWEDEN (46) 8 564 85900 CANADA (1) 905 819 1234 HONG KONG (852) 2814 7431 NETHERLANDS (31) 2972 30630
More informationHaematology/Blood Transfusion. Uncertainty of Measurement values. Haemoglobin g/l / g/l
Haematology/Blood Transfusion Uncertainty of Measurement values Full Blood Count WBC
More informationHemolyzer. 5 NG (closed mode) User Manual. Version 1.35
Hemolyzer 5 NG (closed mode) User Manual Version 1.35 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com agile -
More informationAcute Lymphocytic Leukemia Detection from Blood Microscopic Images
Acute Lymphocytic Leukemia Detection from Blood Microscopic Images Sulaja Sanal M. Tech student, Department of CSE. Sree Budhha College of Engineering for Women Elavumthitta, India Lashma. K Asst. Prof.,
More informationAPPLICATION INFORMATION
A-1994A APPLICATION INFORMATION Particle Characterization USING LASER DIFFRACTION ANALYSIS IN PIGMENT SIZING Introduction Pigments and paints are an important class of industrial materials. They play an
More informationKaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION.
Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION. KALUZA C ANALYSIS SOFTWARE Kaluza C Flow Cytometry Analysis Software is built upon our successful Kaluza Analysis research use platform.
More informationInsight Program Modification
Document Number 61-1075 11/2006 Insight Program Modification Attention: Hematology Laboratory Director Analyzer Operators for Sysmex XE-Series, XT-Series and SE-Series Introduction The Insight Interlaboratory
More informationHow to Use the Lab and Pathology Portlet
The Lab and Pathology Results portlet displays consolidated diagnostic laboratory tests from Ontario Laboratories Information System (OLIS) for patients with an Ontario Health Number. 1. In the Patient
More informationUNIVERSITY OF CALGARY. Chronic Lymphocytic Leukaemia Cell Classification. Emad Amin Mohammed A THESIS SUBMITTED TO THE FACULTY OF GRADUATE STUDIES
UNIVERSITY OF CALGARY Clinical Decision Support System with Adaptive Software Framework for Chronic Lymphocytic Leukaemia Cell Classification by Emad Amin Mohammed A THESIS SUBMITTED TO THE FACULTY OF
More informationHealthInfoNet CLINICAL PORTAL USER REFERENCE GUIDE. Revised: Page 1 of 24
HealthInfoNet CLINICAL PORTAL USER REFERENCE GUIDE Revised: 6.3.2015 Page 1 of 24 HealthInfoNet User Reference Guide INSIDE: Accessing HealthInfoNet (HIN) 3-5 Clinical Portal 6-11 Notifications and Worklists
More informationA Comparative Study of White Blood cells Segmentation using Otsu Threshold and Watershed Transformation
` VOLUME 3 ISSUE 3 A Comparative Study of White Blood cells Segmentation using Otsu Threshold and Watershed Transformation Noorhan M Sobhy, Nancy M Salem and Mohamed El Dosoky Department of Biomedical
More informationRequirements Definition Document (RDD)
Requirements Definition Document (RDD) Revision History Date Version Created By/Revised By: Reason for Revision: 20 Jan 2012 1.0 Tauhid Siddiqui 27 Jan 2012 1.0 Tauhid Siddiqui Incorporating changes suggested
More informationServiceManual. COULTER STKSAnalyzer COULTER STKSAnalyzerwithReticulocyteAnalysis COULTER STKSAnalyzerwithCD4andCD8Lymphocyte Analysis
COULTER COULTER STKSAnalyzer COULTER STKSAnalyzerwithReticulocyteAnalysis COULTER STKSAnalyzerwithCD4andCD8Lymphocyte Analysis ServiceManual STKS PN4235915J (April 1996) COULTERCORPORATION Miami,Florida33196
More informationEdge Detection based Classification of Leukocytes in Blood
Available Online at www.ijcsmc.com International Journal of Computer Science and Mobile Computing A Monthly Journal of Computer Science and Information Technology ISSN 2320 088X IMPACT FACTOR: 5.258 IJCSMC,
More informationBLOOD SMEAR ANALYSIS FOR ACUTE LEUKEMIA DETECTION-MACHINE LEARNING APPROACH
BLOOD SMEAR ANALYSIS FOR ACUTE LEUKEMIA DETECTION-MACHINE LEARNING APPROACH BIJI G Electrical Department, Govt Engineering College, Barton Hill, Thiruvananthapuram, Abstract Whenever the normal functioning
More informationCEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680
Microgenics Corporation Part of Thermo Fisher Scientific CEDIA METHADONE APPLICATION Beckman Coulter AU480 & AU680 Catalog No. 100088, 100097, 1730916 Intended for the Qualitative and Semiquantitative
More informationNear UV Laser System Performance on the CytoFLEX S
Near UV Laser System Performance on the CytoFLEX S APPLICATION NOTE Authors: Jeffrey Cobb James Tung Affiliation: Life Science, Beckman Coulter, Inc., Miami, FL, United States Introduction Material and
More informationHow To Switch Primary And Secondary Axis In
How To Switch Primary And Secondary Axis In Excel 2007 How-to Close the Gaps Between Chart Series in an Excel Stacked Clustered Then change the Series Options Plot Series On to Secondary Axis: image. You
More informationCerner 2015 Upgrade. Tagging. Tagging via the Table of Contents
Cerner 2015 Upgrade This document will demonstrate how to utilize the tagging feature, favorite a note template and carbon copy/forward to a provider a progress note as part of the Cerner 2015 upgrade.
More informationA&S 320: Mathematical Modeling in Biology
A&S 320: Mathematical Modeling in Biology David Murrugarra Department of Mathematics, University of Kentucky http://www.ms.uky.edu/~dmu228/as320/ These slides were modified from Matthew Macauley s lecture
More informationHemolyzer 3 NG. User Manual. Version 1.35
Hemolyzer 3 NG Version 1.35 Analyticon Biotechnologies AG Am Muehlenberg 10 35104 Lichtenfels - Germany info@analyticon-diagnostics.com www.analyticon-diagnostics.com agile - affordable - accurate Contents
More informationDRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800
Microgenics Corporation Part of Thermo Fisher Scientific DRI OXYCODONE APPLICATION BECKMAN COULTER AU480, AU680, AU5800 Catalog No. 100248, 100249, 10015632 The DRI Oxycodone Enzyme Immunoassay is intended
More informationBD CellQuest Pro Software Acquisition Tutorial
BD CellQuest Pro Software Acquisition Tutorial This tutorial guides you through a typical acquisition using BD CellQuest Pro software. If you are already familiar with previous versions of BD CellQuest
More informationAddendum to S.U.N. for version 3.00
Filename: SUN for DTS v3.00 Addendum.doc Doct. Version No: 1 Date: August 2003 Author: M.T.Connah Product Software suite Product Zetasizer Nano series PartNo.-Issue PSS0012-01 PartNo./Version PSW0085/3.00
More informationCEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680
CEDIA BARBITURATES APPLICATION Beckman Coulter AU480, AU680 Catalog No. 100084, 100093, 1661213, 10017365 Microgenics Corporation Part of Thermo Fisher Scientific Intended for the Qualitative and Semiquantitative
More informationTraining Guide. SurgiNet Anesthesia. What's Inside this Guide:
What's Inside this Guide: Table of Contents Tips and Tricks Getting Started Select a Case Starting a Macro Medications Intakes and Outputs Monitored Values Actions Personnel Finalize a Record Training
More informationValley Irrigation Run Time App Version 1.1
Valley Irrigation Run Time App Version. User Guide 09805_0 07 Valmont Industries, Inc., Valley, NE 6806 USA. All rights reserved. www.valleyirrigation.com Table of Contents Valley Irrigation Run Time App
More information