i Note Intrusion Control Panel Solution 64 Release Notes for Version Release Notes March, 2007

Size: px
Start display at page:

Download "i Note Intrusion Control Panel Solution 64 Release Notes for Version Release Notes March, 2007"

Transcription

1 Intrusion Control Panel Solution 64 Release Notes March, 2007 Release Notes for Version In the interest of ongoing product development and improvement, Bosch is proud to release software version 1.50 for the Solution 64 Security Control Panel. This document briefly outlines the new features and improvements added in this release. Please read in conjunction with the current installation manual and other addendums for more detailed information. To coincide with this release, we are pleased to also announce that Version 1.07 of our Solution Link Upload/Download software is now available. Version 1.07 includes increased functionality, as well as support for the additional features in the V1.50 Solution 64 release. Support for up to 128 User PIN Codes Support for up to 128 Token Users Support for up to 128 RF Keyfob Users Support for Multi-Tenant Applications 1) NEW Users Increased to 128. Version 1.50 includes support for up to 128 users. Each user can have a unique PIN number, Token and RF Keyfob if required. Version 1.50 is supplied in all panels produced after March It is not possible to upgrade panels manufactured earlier than this date to 128 user capacity due to hardware differences. The manufacture date can be found on the product identification sticker located on the main PCB. A number of additional options and features in the V1.50 release were originally released in V1.10. To find out more, please take the time to also read the release notes for V ) NEW Multi - Tenant Mode Added. Version 1.50 includes additional support for multi-tennant applications such as self storage garages or school storage lockers etc. When enabled, the new option Multi Tenant Mode option in MENU will lock the first 48 users on the system to the first 48 zones on the system. Each time the user enters their PIN the corresponding zone is automtically bypassed allowing them to access the zone (area). Users 49 to 128 continue to operate as normal users. System > Installer Options > Installer Options MENU Report / Log Entry / Exit Installer Menu N 2 Report / Log Program Data Changed Y 3 Arm Only Installer PIN N 4 Zero Exit Time N 5 Auto Exit Installer Menu In 2 Hours Y 6 Auto Exit Service Mode In 2 Hours Y 7 Multi-tennant Mode N 8 Factory Defaulting Allowed Y Security Systems

2 The following options are included in this release however their functionality has been disabled as they are for future use. Please ignore the following options in this release. MENU 5-5, MY Alarm MENU 5-0-3, Check Web MENU 5-0-4, System Log MENU 5-0-8, Register Customer MENU 5-0-9, Register Installer MENU 5-3-8, User RAS PIN Bosch security Systems BLCC110 N1.50 Issue: FTR1.5 3/07 Release Notes Solution 64

3 Intrusion Control Panel Solution 64 Release Notes March, 2007 Release Notes for Version In the interest of ongoing product development and improvement, Bosch is proud to release software version 1.10 for the Solution 64 Security Control Panel. This document briefly outlines the new features and improvements added in this release. Please read in conjunction with the current installation manual and other addendums for more detailed information. To coincide with this release, we are pleased to also announce that Version 1.07 of our Solution Link Upload/Download software is now available. Version 1.07 includes increased functionality, as well as support for the additional features in the V1.10 Solution 64 release. Support for up to 3 x CM104 Zone Expanders Support for up to 3 x CM110 Output Expanders Support for up to 3 x CM120 LAN Power Supplies Full Area and Output Control via DTMF Support for up to 6 x PR100 Proximity Readers Added End Of Exit Beep when Part Arming Added Option to Arm All User Areas Via Prox Added Option to Expire PIN on a per User Basis Added Zone Trigger Delay Option Added Support For Remote Keypad Simulator 1) NEW Support For 3 x CM104 Zone Expander Modules. Version 1.10 includes support for up to three CM104-8/16 Zone Expansion modules. This allows zones to be located in four separate locations or buildings using individual modules which are then wired back to the control panel via the 4 wire LAN. All zones follow the global EOL setting in MENU regardless of which module they are on. i.e. If Split EOL is selected, then all zones will be configured for Split EOL. Zone numbering is automatically assigned by the panel during power up depending on the module configuration found. For example if Split EOL is selected and 3 x CM104 Zone Expanders are fitted, then Zones 1-16 will be located on the main panel, Zones will be located on CM104 Expander 1 and Zones will be located on CM104 Expander 2. ZONE CONFIGUR ATION TABLE Device Type Single EOL Alarm + Tamper Split EOL Solution 64 Panel RF Zones CM104 Expander CM104 Expander Any CM104 Expander number up to a Total Zones maximum Solution 64 Panel of 64 CM105 Expander zones CM106 Expander CM106 Expander N/A Total Zones If a mixture of hardwired and RF zones are being used, then it is recommended that you assign the RF zones to zone numbers above the maximum number of hardwired zones. In the above example you would assign the first RF zone to Zone 49 which would leave all 48 hardwired zone inputs free. If an RF zone is assigned to a zone which has a physical hardwired input then the RF zone will take precedence and the hardwired zone input will be disabled. At this time the panel supports either CM104 zone expanders OR CM105 zone expanders however is not possible to mix both types on the one system. See the zone configuration table for the various zone configuration options available. RF zones are available regardless of which hardwired zone options are used. 2) NEW Support For 3 x CM110 Output Expander Modules. Version 1.10 includes support for up to three CM110-4 Way Relay Output Expanders. This feature takes the maximum output capacity of the panel to 16 high current outputs. Outputs can be located in up to four different locations or buildings using individual modules which are then wired back to the control panel via the 4 wire LAN. This additional module support also provides for up to 6 external access control doors via the dual proximity reader inputs located on the CM110 Expanders. The CM110 inputs currently support the PR100 External Proximity readers which are compatible with the Proximity Keypads. The total number of access control doors now increases to 14. ACCESS DOOR T YPE / CAPACIT Y Firmware Internal External Total V or lower V or higher Output and Proximity Reader numbering is automatically assigned by the panel during power up depending on the module configuration found. Security Systems

4 For example if 2 x CM110 Output Expanders are fitted then Outputs 1-4 will be located on the main panel, Outputs 5-8 will be located on CM110 Expander 1 and Outputs 9-12 will be located on CM110 Expander 2. OUTPUT AND PROX READER MAPPING Device Type O utput Number Reader Number Solution 64 Panel 1-4 N/A CM110 Expander CM110 Expander CM110 Expander Proximity Readers 1-8 are reserved for Keypad Readers. External readers are addressed as readers 9 to 14. When connected to the panel using either dial up or direct connection modes, the keypad simulator option will be available via the Solution Link tool bar. The keypad simulator allows you to view any keypad on the system as well as perform any available keypad functions via the PC. 5) Output Polarities With Pre Delay. In earlier versions, outputs programmed with output polarity Low With Pre Delay and Open With Pre Delay did not function correctly. The output would operate after the pre delay time expired however the output would then reset rather than remain latched on. This operation has been corrected in this release. 3) NEW Support For 3 x CM120 Power Supply Modules. Version 1.10 includes support for up to three CM120-1 Amp LAN Power Supply Modules. CM120 modules can be located in up to three different locations or buildings to provide LAN voltage regeneration as well as supplying power to other modules, Intrusion Sensors, Door Strikes etc. The CM120 modules are designed to run off a standard plug pack transformer and include built in battery chargers suitable for charging 12V 7Ah batteries. As with all LAN modules, the status of the CM120 is constantly being monitored and reported to the control panel via the system LAN. MODULE CONFIGUR ATION INFORMATION Multiple module support requires that each module is set to a unique address. For example if a system has 1 x CM104 and 1 x CM120 installed, they should both be addressed as module 1. If an extra CM104 was fitted then it should be addressed as module 2. The panel will only look for new devices follwing a power cycle and only if the LAN is not secured. To add new devices, make sure the LAN is unsecured before powering the system down. Set the module Address DIP switches accordingly and complete wiring as per instuctions. Once complete re-power the system. To interrogate devices connected to the LAN you can use LAN Status command, MENU L AN MODULE ADDRESSING Module Nº SW 1 SW 2 SW 3 1 OFF OFF OFF 2 ON OFF OFF 3 OFF ON OFF Each different module type should be addressed starting at address 1. 4) NEW Support For Keypad Simulator Added Version 1.10 includes support for the real time keypad simulator. The keypad simulator is a new feature which can be accessed via the latest version of our Solution Link RAS software. 6) Battery Test On Arming Option. In earlier versions, the system would always perform a battery test on arming regardless of whether or not the Battery Test On Arming Option was selected. This operation has been corrected in this release. See MENU ) Outputs Programmed To Follow Chime Zones. In earlier versions, an output configured to operate when a chime zone was triggered would not reset if the chime function was turned off for that area while a chime alarm was in effect. This operation has been corrected in this release. See Output Event Type 30 - Chime Zone Triggered 8) Outputs Programmed To Follow Auto Arm Pre-Alert. In earlier versions, an output configured to operate when an Auto Arming Pre Alert timer was running would not reset if the Auto Arm Time was delayed buy a user. This operation has been corrected in this release. See Output Event Type 31 - Auto Arm Pre Alert 9) NEW Panel DTMF Control Functions Enhanced. In earlier versions, DTMF control functions were restricted to remote arming of the entire system only. Version 1.10 now includes comprehensive DTMF control of individual areas and outputs with full user PIN and TIMER GROUP access verification. Comms > Remote Access > DTMF Options MENU DTMF Arming Y 2 DTMF Disarming N 3 DTMF User Functions N 4 DTMF Quick Arming Y 5 Reserved N 6 Reserved N 7 Reserved N 8 Reserved N 2 Bosch Security Systems 3/07 FTR1.4

5 Unlike other systems, no additional hardware or modules are required for DTMF control. To configure the desired functions see MENU DTMF Options. See below for DTMF control operating instructions. 1. Once the panel answers the incoming call, if either option 1, 2, 3 or 4 in MENU is enabled, then the panel will play a short welcome jingle. You now have approximately 5 seconds to enter a valid PIN and log onto the panel. 2. Enter PIN followed by the # key. If the PIN is valid the system will respond with two short beeps. If the PIN is invalid then a single long beep will be heard. If a valid PIN is not entered in time, the panel will attempt to establish a modem connection as if connecting to the Solution Link software. If this happens you will need to hang up for approximately 60 seconds before trying again. 3. Once validated, the following commands can be performed. See the table below. If no keys are pressed for 20 seconds then the panel will play the exit jingle before terminating the session and hanging up. Pressing ## at any time while connected will cause the panel to terminate the session. DTMF CONTROL FUNC TIONS Operation Command Response Quick Arm All Areas 0 + # 2 x Beeps Log In OK USER PIN + # Welcome Jingle Log In Failed USER PIN + # Long Beep Turn Area ON 1 + (Area Nº1-8) # Turn Area OFF 1 + (Area Nº1-8) # 2 x Beeps (Low - High) 2 x Beeps (High - Low) Turn Output ON 2 + (Output Nº1-16) # 2 x Beeps (Low - High) Turn Output OFF 2 + (Output Nº1-16) # 2 x Beeps (High - Low) End Session # + # Exit Jingle DTMF EXAMPLES Each example below shows the log on step for clarity. In practise is only necessary to log on once per DTMF control session. To turn Area 1 ON enter the following # = Log ON # = Arm Area 1 To turn Output 10 ON enter the following # = Log ON # = Turn Output 10 ON To turn Output 12 OFF enter the following Solution # = Log ON # = Turn Output 12 OFF If the DTMF Quick Arm option is enabled then it is possible to remotely arm all areas without logging onto the panel. Simply enter 0 + # following the welcome jingle. Make sure that the phone being used to remotely control the panel is set to transmit DTMF tones when keys are pressed during the call. This option is disabled by default on some phones. 10) Send Test Report Menu Changed. In earlier versions, a Guest User or a Non Master Code User could initiate a test report transmission via the hold down function on the keypad yet they had no access to this option via the menu tree. (See MENU 5-9-0) V1.10 now allows Guest / Non Master Users to access this menu. 11) Random A.C. Reports Option Corrected. In earlier versions, the option to randomise A.C. Fail reports (MENU 7-3-0) when selected would only randomise across a 120 second time window instead of a 2 hour time window. This has been corrected in this release. This option can be used to minimise the incoming traffic to the control room in the event that power is lost to large parts of a suburb due to catastrophic equipment failure, storm damage etc. 12) Delay Zone Reports Option Corrected. Each zone can be individually programmed for delay reporting in MENU When enabled, the zone reports will be delayed by the time period set in MENU This option can be set to allow a user to enter their PIN and disable the alarm report in case they have caused a false alarm. In earlier versions, the Delay Zone Reporting Option ignored the delay time and reported the event immediately. This has been corrected in this release. 13) Alarm Memory For Keypad Generated Alarms Added. In earlier versions, when a keypad generated alarm such as a keypad fire, keypad medical or keypad panic alarm was triggered, the keypad would only display the alarm event on the keypad while the sirens were running. In this release, the system will display alarm memory for all keypad generated alarms. 14) Alarm Memory For Telco Line Fail Alarms Added. MENU includes an option for the panel to generate an alarm should a Telco Line Failure occur. This option is enabled by default and will only trigger the alarm event if the panel is in the armed state. Bosch Security Systems 3/07 FTR1.4 3

6 In earlier versions, a Telco Alarm Fail would generate the alarm as programmed however no alarm memory would be displayed on the keypad once the sirens timed out. In this release, the system will display alarm memory for Telco Line Fail alarms. 15) Bypass Reports For Non Burglary Zone Types. In earlier versions, the Report Bypass option in MENU for Non Burglary Zones like Keyswitch, Display Only and 24hr Non Burglary was being ignored and no bypass / un-bypass reports would be sent to the control room for these zone types. In this release all zone types will follow the Report Bypass option programmed in MENU ) NEW End Of Exit Beep In Part Mode Added. In earlier versions, arming in Part Mode 1 or 2 would start the exit timer and count down display however unlike All On arming there was no audible indication. This release now includes an End Of Exit beep indication which will sound when the exit timer expires. To disable this function remove the exit warning option in MENU Beeper Options. 17) NEW Force Alarm On Zone Tamper Option Added. In previous versions, if the area was in the disarmed state and a zone tamper alarms was triggered, the system would report the tamper alarm to the control room and display on the keypad but would not trigger the sirens unless the area was armed. Version 1.10 includes a new Alarm On Tamper input option which when set will force the sirens to trigger regardless of whether or not the area is armed. See MENU Option 6 Alarm On Tamper. 4 Inputs > Global Input Options > Input Options MENU Tamper On Short N 2 Reserved N 3 Response Time 500ms N 4 Reserved N 5 Keyswitch Open/Close Y 6 Alarm On Tamper N 7 Reserved N 8 Reserved N This option only takes effect when the EOL value has been set to Alarm + Tamper monitoring in MENU 3-4-0, Option 11, 12 or 14, or for RF device tampers. 18) Sequential Handover And Bypassed Zones. In previous versions, if the sequential handover option has been selected in MENU and a zone which is in the entry path has been bypassed, the system would generate an alarm because the entry sequence was not sequential. To prevent this scenario from occurring Version 1.10 now excludes bypassed zones from the sequential handover list. 19) Output Timing Parameter Corrected. In earlier versions, outputs which were configured to run or operate for longer than 1 hour would fail to run for the programmed time period. V1.10 includes a correction to the timer function which now allows outputs to run for the programmed time period regardless of length. 20) Menu Text Changes And User Interface Improvements. The following changes have been made to improve clarity for all users. 1. MENU now reads View RF Device ID. 2. MENU 1-4-2,option 6 now reads Always Report Op/Cl. 3. MENU 7-7-0,option 5 now reads Cannot Change Own Pin. 4. The phrase ALLON in some menus has changed to ALL ON. 5. When an output went into a trouble condition, the keypad would display a System Trouble Alert Box and an Output Trouble Alert Box. This release no longer displays the System Trouble Alert Box for faulted outputs as it served no purpose. 21) NEW SMS Reporting To Pager Networks. A new transmission format has been added in this release to cater for SMS reporting to pager networks which do not implement parity such as Link Paging. See Transmission Type 14 - SMS NO PARITY. You should verify the required protocol for your pager company before implementing this option. 22) Area Senior Watch Alarm Reports. (Dead man Alarm) In earlier versions, if Senior Watch in MENU was enabled for an area and the Senior Watch Time Period in MENU was set to 0 (zero) the system could generate spurious dead man reports to the control room. This has been corrected in this release so that Senior Watch alarms will only be generated if the time period is set greater than 0 (zero). 23) Alarm On Exit Error Reporting Corrected. In earlier versions, no report was sent when an Alarm On Exit Error occured if the transmission format was set to Contact ID. SIA and other transmission formats where not effected. This has been corrected in V1.10 and the system now reports CID event 374 when an Alarm On Exit Error occurs. 24) User Duress Reports in SIA Format Corrected. In earlier versions User Duress reports were not being sent if the transmission type was set to SIA format. This has been corrected in V1.10 and the system now reports User Duress alarms when SIA transmission format is selected. Bosch Security Systems 3/07 FTR1.4

7 25) Output Polarity One Shot + Retrigger Corrected. In earlier versions, outputs programmed with a polarity type of One Shot + Retrigger did not operate correctly. The output failed to reset the one shot timer when the event retriggered which meant that output would operate at the specified one shot time rather than being reset for each retrigger. This has been corrected in V1.10 so that each retrigger causes the one shot timer to reset. 26) NEW Zone Trigger Delay Option Added. Version 1.10 includes a new Zone Trigger Delay option which can be used to delay or hold off the alarm for a period of time. This function can be used when monitoring pump alarms, temperature alarm and freezer alarms. This option can also be used to create a Door Open To Long input when implementing access control functionality. The zone delay option is selected under the pulse count option in MENU Option 13, 14 and 15 allow you to select the pulse delay in scale. Options are Seconds, Minutes or Hours. Once the scale is set you can then set the multiplier value under MENU See examples below. ZONE DEL AY TRIGGER EXAMPLES Configure Zone 3 with Delay of 3 minutes (180 seconds). 1. Program zone type etc as per normal. Then set Zone 3 to Pulse delay scale SECONDS in MENU 3-1-3, option Set the zone 3 delay multiplier in MENU to If zone 3 is triggered and it remains open for 180 seconds, then an alarm event will be triggered. If the zone re-seals within the 180 second period then the counter will reset and no alarm will be triggered. Configure Zone 10 with Delay of 1 hour (60 minutes). 1. Program zone type etc as per normal. Then set Zone 3 to Pulse delay scale HOURS in MENU 3-1-3, option Set the zone 3 delay multiplier in MENU to If zone 3 is triggered and it remains open for 1 hour, then an alarm event will be triggered. If the zone re-seals within the 1 hour period, the counter will reset and no alarm will be triggered. The trigger delay multiplier in MENU will always display the number and the word seconds. This is because this this option has a dual function. When setting zone delay you should ignore the word seconds and simply multiply the number by the scale option selected to calculate the actual delay time. 27) Alarm On Output Device Fail. In earlier versions, if the Alarm on Device Fail option in MENU was set and the system was disarmed when the device failure occured the system would send the report to the control room but would not trigger the sirens. This has been corrected in V1.10 release. Solution 64 28) User PIN Expire Option Enhanced. In earlier versions, the user expire option used a common timer for all users which was not practical. The V1.10 release includes a new option which allows you to set any user s pin to expire at specific time. MENU is used to set the Expire Date for each user. To activate the user expire function you also need to set the User Expire option in MENU User Options, PIN Expires for each user. The user expire date in MENU can be changed by master code user allowing them to extend or shorten the expire time if required. 29) NEW Arm All User Areas Via Prox Reader. In earlier versions, it was not possible to set a prox reader to Arm / Disarm all areas which a user belongs to with one presentation of their token. Version 1.10 includes a new reader option in MENU Option 8 called All User Areas. When set the option will cause the system to arm / disarm all areas which the token holder belongs to on a single token presentation. This option can be set per reader. Access > Prox Reader > Reader Options MENU All On Arming Allowed Y 2 Disarming Allowed Y 3 Enable Badging N 4 Zero Exit Time N 5 Part On Arming Allowed N 6 Arm If Single Area User N 7 Reserved N 8 All User Areas N 30) Roaming Keypad Prox Reader Operation Changed. In earlier versions, if a multi-area user presented their token to a roaming keypad reader, the system would disarm the first area which they belonged to and keep them logged on to the system. In Version 1.10 the operation has been changed so that multiarea users will only be logged on when presenting their token to a roaming keypad reader. Once logged on the user can hold down the All On or All Off keys to arm / disarm all areas they belong to or use the arrow keys to navigate to a specific area and then press the On/ Off key as required. 31) RAS Disconnect On Alarm Operation Changed. In earlier versions, if MENU option 3, Abort RAS on Alarm was enabled the panel would terminate the RAS programming session regardless of whether or not the session was a remote or a direct connection. In Version 1.10 this option has been changed and will now only terminate the programming session if it is a remote connection. A direct connection will remain connected. Bosch Security Systems 3/07 FTR1.4 5

8 32) NEW User RAS Security PIN Option Added. A new option has been added in this release to allow for an independant User connection to the panel using our Solution Link End User programming software. MENU 5-3-8, User RAS PIN option is defaulted to and is currently reserved for future use. In Version 1.10 the default event assigment for all outputs has been changed to 0. Outputs > Properties > Event Assignment MENU ) NEW Telephone Ring Count Analysis Changed. The way ring counting is analysed for the Australian ring tone has been changed in V1.10 to make it easy for new users to learn and simpler to use when establishing a remote connection. In earlier versions, the panel would count rings as follows, RING.. RING... RING.. RING would be counted as 1 ring. In V1.10 the panel will now count rings as follows, RING.. RING will be counted as 1 ring. Event Assignment Op Press 0-9 OK to SAVE 36) NEW Keypad Emergency Alarm Trigger s. Version 1.10 introduces a new method for triggering keypad Fire, Medical and Panic alarms. Occasionally you will hear half a ring at the moment the line is switched through to the premises. In this case the panel will count the rings as follows,.. RING...RING.. RING would be counted as 1 ring. 34) NEW Ring Count Default Changed. To allow for the changes in the ring count analysis in V1.10 the default ring count has been changed from 10 rings to 20 rings. The maximum number of rings which can be programmed has also been increased from 15 to 30 rings. Comms > Remote Access > Ring Count MENU = No Answer 20 1 to 30 = Answer Ring Count This menu sets the number of rings the panel will wait until answering an incoming call. Programming a zero will stop the panel from answering any incoming calls. Ring Count P Rings Press 0-9 OK to SAVE 35) Output Event Assignment Default Changed. The output event assignment option allows you to assign or map an Output event to an Area number (1 to 8), a User number (1 to 128), a Zone number (1 to 64) or a Group number (1 to 8) that the output will follow. Programming a zero will assign the output event to follow all areas, users, zones or access groups depending on the event type. Refer to Output Event Type Table in the Installation manual for a complete listing of available options. The new methods are easier for the end user to remember and also allow for labelling to be applied to the keypad further simplifying operation. At this time both old and new methods function. NEW KEYPAD EMERGENCY ALARM TRIGGER S Key Sequence Ë + Ê Hold for 2 seconds Ê + È Hold for 2 seconds È + Â Hold for 2 seconds Event Triggered Keypad Fire Alarm Keypad Panic Alarm Keypad Medical Alarm 37) D Type Receiver Re-named Bosch Serial Receiver. In Version 1.10, Option 4 in MENU has been re-named from D Type Serial Rcvr to Bosch Serial Receiver. Both RF3212 and RF3212E receivers from Bosch are supported by this option. The following options are included in this release however their functionality has been disabled as they are for future use. Please ignore the following options in this release. MENU 5-5, MY Alarm MENU 5-0-3, Check Web MENU 5-0-4, System Log MENU 5-0-8, Register Customer MENU 5-0-9, Register Installer MENU 5-3-8, User RAS PIN Bosch security Systems BLCC110 N1.10 Issue: FTR1.4 3/07 Release Notes Solution 64

9 Intrusion Control Panel Solution 64 Release Notes July, 2006 Release Notes for Version In the interest of ongoing product development and improvement, Bosch is proud to release software version for the Solution 64 Intrusion Control Panel. This document briefly outlines the improvements added in this release. Please read in conjunction with the current installation manual and other addendums for more detailed information. 1) Zone Status Indicator (Green LED) Function Corrected. Normally the Green Status indicator LED on the keypad will flash to indicate that a zone or zones are unsealled and would remain on steady when all zones are sealled. If however the zone is an RF Zone which has been programmed for pulse count and the zone remains open for longer than 10 seconds then the status indicator will continue to flash even if the zone reseals. This issue is only relevant if the Zone is an RF Zone and it has been programmed for pulse count. This has been corrected in V ) RF Zone Pulse Count Function Corrected. In previous versions any RF Zone programmed for pulse count which was left unsealled when the area was armed would cause an alarm to occur the next time the devices supervision signal was received by the panel (approximatly 10 minutes after arming). This has been corrected in V

10 The following options are included in this release however their functionality has been disabled as they are for future use. Please ignore the following options in this release. MENU 55 - MY Alarm MENU Check Web MENU System Log MENU 508 -Register Customer MENU 509 -Register Installer Bosch Security Systems BLCC110N Issue: FTR1.3 7/06 Release Notes Solution 64

11 Intrusion Control Panel Solution 64 Release Notes April, 2006 Release Notes for Version 1.05 In the interest of ongoing product development and improvement, Bosch is proud to release software version 1.05 for the Solution 64 Intrusion Control Panel. This document briefly outlines the numerous new features and improvements added in this release. Please read in conjunction with the current installation manual and other addendums for more detailed information. To coincide with this release, we are pleased to also announce that Version 1.03 of our Solution Link Upload/Download software is now available. Version 1.03 includes increased functionality, as well as support for the additional features in the V1.05 Solution 64 release. Support for Tamper Keypads added Installer Default Lockout Indication added User ID for Keyfob Panic and Low battery added Arming in Part Mode 1 and 2 Via Prox Readers Token Control Via Common Area Keypads 3) Telco Line Fail Reporting Corrected. In previous versions a telco line fail would be reported as a Contact ID event E351 with C001 instead of E351 with C891, where C891 represents panel number 1 in the base station template. The telco line restore reports correctly as event R351 with C891. This has now been corrected in V ) NEW Support Added For Tampered Keypads. Version 1.05 includes support for the recently released tampered keypads which are available with or without built in proximity readers. The Enable Rear Tamper option (MENU 6-1-4, Option 4) needs to be enabled for each tampered keypad fitted to the system. Devices > Keypads > General Options MENU Keypad Extinguish N 2 Greeting On Arm Y 3 Greeting On Disarm Y 4 Enable Rear Tamper N 5 PIN To Change Area N 6 Home Area Only N 7 Report Keypad Temperature Y 8 Display Area Indicators N The above options can be configured independantly for each keypad fitted to the system. 2) NEW Panel Default Lockout Indication. In earlier versions it was difficuilt to determine if panel defaulting had been disabled. When this option has been set via MENU 7-7-4, it is impossible to default the system without knowing the installer code. In this release, if the installer default function has been disabled then the panel will pulse or click the line seize relay 4 times during power up. If this occurs and the installer code is unknown you will need to return the panel to the place of purchase for defaulting. Charges may apply for this service. 4) NEW Keyfob Panic And Low Battery Reports By User In previous versions it was not possible to indiviually report RF keyfob panic alarms or low battery events per user. in V1.05, zones number 301 to 428 have been assigned to represent keyfob events for users 1 through to user 128. This feature now allows the panel to be used in portable duress alarm applications where positive user identification is required. Eg. A keyfob panic alarm triggered by user 26 will report as E120-GG-Zn326. See the Base Station Reporting template V1.04 or higher for more information. 5) NEW Token Control Via Common Area Keypads. In previous versions, if a user who belonged to only one area presented their token to a roaming prox keypad reader, the system would log them on and move the keypad to display the users area. To arm the area the user would need to swipe their token a second time. In this release a new option called Arm If Single Area User has been added to the Reader Options MENU When this option is set, a user who belongs to a single area only needs to present their token once to the keypad for the area to arm. This function only works via keypad readers and for users who only belong to one area. 6) Screen Saver Display Corrected. In previous versions the area armed, disarmed and part armed icons where not being displayed when the keypad was in screen saver mode. In V1.05 the icons are displayed correctly when in screen saver mode.

12 7) NEW Arming In Part Mode Via Prox Readers. In previous versions it was not possible to configure a reader to only allow arming in Part mode as the reader still required the Arming Allowed option to be enabled. In this release the arm in part mode via prox reader feature has been improved and it is now possible to configure a reader to only allow arming and disarming from part mode. To configure the reader for part arming only, select option 5, Part On Arming Allowed and deselect option 1, All On Arming Allowed in the Reader Options MENU Once enabled, swiping the token once will arm the area in part mode 1. If part mode 2 zones have been programmed, swipe the token a second time within 5 seconds and the area will arm in part mode 2. See below for text changes and additional options in the Reader Options Menu. Access > Prox Reader > Reader Options MENU All On Arming Allowed Y 2 Disarming Allowed Y 3 Enable Badging N 4 Zero Exit Time N 5 Part On Arming Allowed N 6 Arm If Single Area User N 7 Reserved N 8 Reserved N The above options can be configured independantly for each prox reader or prox keypad fitted to the system. The following options are included in this release however their functionality has been disabled as they are for future use. Please ignore the following options in this release. MENU 55 - MY Alarm MENU Check Web MENU System Log MENU 508 -Register Customer MENU 509 -Register Installer Bosch Security Systems BLCC110N1.05 Issue: FTR1.2 4/06 Release Notes Solution 64

13 Intrusion Control Panel Solution 64 Release Notes February, 2006 Release Notes for Version In the interest of ongoing product development and improvement, Bosch is proud to release software version for the Solution 64 Intrusion Control Panel. This document briefly outlines the numerous new features and improvements added in this release. Please read in conjunction with the current installation manual and other addendums for more detailed information. To coincide with this release, we are pleased to also announce that Version 1.03 of our Solution Link Upload/Download software is now available. Version 1.03 includes increased functionality, as well as support for the additional features in the V Solution 64 release. Latching Chime Mode added Tone Bypass support for RAS Connection added Automatic Smoke Detector Reset added Installer Code can now be restricted per Keypad Various Panel Defaults Have been Improved Fire Zone Testing Improved AutoArm Multiple areas by Schedule Improved 3) NEW Latching Chime Zone Option Added. It is now possible to select Chime mode to latching on a per area basis. When this option is selected, if a chime zone is triggered then any outputs programmed for chime alarm and or the keypads sounder will trigger and remain on until a valid user code is entered. The keypad will display the zone which triggered the chime alarm. Areas > Commands > Chime Mode MENU ) NEW Automatic Smoke Sensor Reset Option Added. Version includes a new option which when set, will trigger any output that is programmed as event type 49 - Smoke Sensor GND to operate on the next arming cycle, therefore resetting the connected smoke sensors each time the area is armed. If this option is not set then a manual reset will need to be performed via MENU Areas > Properties > Input Options MENU Non Sequential Handover (Entry Path) Y 2 Pulse Count Handover Allowed Y 3 Senior Watch N 4 Reset Smoke on Arming Y 5 Reserved N 6 Reserved N 7 Reserved N 8 Reserved N 2) Keypad Quarantine In earlier versions, if the keypad lockout time was set to 000 seconds and the maximum number of code retries was exceeded, then the keypad siren would sound and the keypad would be quarantined indefinitely. In this release, if the keypad lockout time is set to 000, and the code retry count is exceeded, the keypad siren will sound but the keypad will not be quarantined. Entering a valid code will reset the keypad siren. The Chime Mode option allows you to program how chime zones will operate on an area by area basis. In latching mode a valid PIN will need to be entered to reset the chime alarm. Available options include; Chime Always Chime For 000 Seconds Chime After 000 Seconds Chime Latching 4) Swipe Token Text Changed In Version , the keypad now prompts with the words Present Token instead of Swipe Token when learning a Token or Card into the panel. 5) Keypad Back light Function Changed On previous releases, the keypad back light would occasionally not switch to full brightness when a user token was presented to the keypad reader. In this release the panel will send an awaken command to all keypads when the system is armed forcing the back light to return to full brightness. 6) Zone Status Display Improved The zone status command, MENU has been improved in version and now displays the zone condition as well as the measured EOL resistance value. 7) Call Diversion Function Changed In previous versions, if a call diversion string has been programmed, the panel would activate the call diversion when the panel was armed in either the Part On mode or All On mode. In this version, the call diversion will only activate when the panel is armed in the All On mode.

14 8) NEW Restrict Installer Access Per Keypad Option Added. In installations with multiple keypads, you may want to restrict the installer code access to one or a limited number of keypads. For example you may want to restrict installer access to only the keypad which is located in the communication room. To configure this option, select Installer PIN Not Allowed option for each required Keypad. See MENU 6-1-5, Option 7 below. 9) NEW Prevent PIN Arm/Disarm Per Keypad Option Added. Situations may arise where a keypad is required for access door control only. In this situation to prevent Arm/ Disarm control, set the PIN Arming Not Allowed option for each desired keypad. Valid user codes with the appropriate access level can still be used to operate the door strike from the keypad when this option is set. See MENU 6-1-5, Option 6 below. Devices > Keypads > Beeper Options MENU Trouble Alerts Y 2 Entry Warning Y 3 Exit Warning Y 4 Chime Tone Y 5 Display Temperature N 6 PIN Arming Not Allowed N 7 Installer PIN Not Allowed N 8 Show Alarm When Armed N The above options can be configured independently for each keypad fitted to the system. 10) Manual Output Control with Inverted Polarity In earlier versions, the keypad text prompts did not reflect the correct output polarity for outputs which are configured to be on in the normal state. For example Output 3 is defaulted to polarity type Low One Shot Open, which means that in the normal state the output is on. In version the text prompts now correctly follow the output polarity selected for each output. 11) NEW Zone Testing When Arming When arming, the panel will notify the user about any zones which are currently unsealed. At this point the user can abort the arming process and seal the offending zone, or they can force arm (if allowed) leaving the zone open in which case a trouble will be reported. In version , if the force arm prompt appears when arming, the user can press the ON key again, and the system will re-scan the zones. Any previously open zones that have re-sealed will not trigger the force arm prompt after the re scan. 12) First To Open Last To Close Option Corrected The first to open last to close option, (MENU 7-7-1) did not function correctly in previous versions. This has been corrected in this release and the system now sends a close report when all areas are armed, and an open report when the first area is disarmed. System > System Options > Area Options MENU Area 1 = Common Area N 2 First To Open Last To Close N 3 Reset Siren All Users ( All Areas) Y 4 Power Up In Same State As Powered Down Y 5 Fault Acknowledge All Areas Y 6 Delay Trouble Beeps Y 7 Reserved N 8 Reserved N (*** System Wide Parameter ***) 13) NEW Panel Default Changes A number of system defaults have been changed to better reflect the most commonly chosen options. See below. a) MENU Open Zone On Lost RF This option has been defaulted to NO because when and RF Zone fails it s supervision check, a report is automatically sent to the control room. Device > RF Devices > RF Device Options MENU Display RF Tamper Y 2 Report RF Tamper Y 3 Report RF Low Battery Y 4 Report Lost RF Device Y 5 Open Zone On Lost RF N 6 Audible Keyfob Panic Y 7 Report Keyfob Panic Y 8 Keyfob Function 1 Key = Part On Y b) MENU Alarm On Line Fail If Armed This option has been defaulted to YES because more often than not, if an intruder cuts the telco line you would want the sirens to sound. Comms > Properties > Phone Line Options MENU Display Telephone Line Fail Y 2 Report Telephone Line Fail Y 3 Alarm On Line Fail If Armed Y 4 Alarm On Line Fail If Disarmed N 5 Reserved N 6 Reserved N 7 Reserved N 8 Display Phone In Use N c) MENU Delay Trouble Beeps This option has been defaulted to YES based on customer feedback. When set to YES the system will prevent trouble beeps from the keypad between 10pm and 7am. Bosch Security Systems 2/06 FTR1.1

15 Should the trouble event still be in effect at 7am the keypad beeper will start to sound. At all times the trouble event will be displayed on the keypad and stored into the system log. d) MENU Reset Siren All Users This option has been defaulted to YES because in most cases in a partitioned system you would want all authorised users to be able to reset the sirens. System > System Options > Area Options MENU Area 1 = Common Area N 2 First To Open Last To Close N 3 Reset Siren All Users ( All Areas) Y 4 Power Up In Same State As Powered Down Y 5 Fault Acknowledge All Areas Y 6 Delay Trouble Beeps Y 7 Reserved N 8 Reserved N (*** System Wide Parameter ***) e) MENU Duress Allowed This option has been defaulted to YES as there is very little chance that a user would repeat the last two digits of their code by accident when disarming. Areas > Properties > General Options MENU Exit Time Restart N 2 Reset Alarm Memory On Disarm N 3 Duress Allowed Y 4 Acknowledge All Faults N 5 Single Button Arming - All On Y 6 Single Button Arming - Part On Y 7 Link To Common Area Y 8 Single Button Part Off N f) MENU Service Interval The default Service Interval has been changed to 000 weeks. This means that from default, no service reminder will be given. If you want to take advantage of this feature you will need to program the number of weeks to wait between reminders into this location. Areas > Area Testing > User Test Interval MENU (*** System Wide Parameter ***) DAYS 14) RF Keyfob Panic Operation Corrected In previous versions, triggering an RF Keyfob panic for any user assigned to any area other than area 1, would cause the system to loop on area 1, requiring a system power cycle to recover. This has been corrected in the release and the loop function now increments through all areas on the system. Users assigned to multiple areas are not effected provided they also have access to Area 1. 15) NEW Auto Arming All Areas In earlier versions, auto arming multiple areas required multiple schedules. In version it is now possible to arm all areas using just 1 schedule. To do this select the corresponding auto arm schedule and set it s index to 000. See MENU System > Schedules > Index MENU ) Recurring System Report Linked to Swinger Dialler Count. In previous versions, a recurring system trouble event would send a new report each time the event occurred, without any swinger dialler override. In V System Trouble events have been linked to the swinger dialler setting in MENU This means that a recurring system trouble event will only report until the swinger dialler count is reached and then it will be locked out. The event will reactivate the next time any area is armed or disarmed. System trouble events will only trigger the sirens, if applicable once per arming cycle. Comms > Dialler Reporting > Swinger Dialler MENU (*** System Wide Parameter ***) ) Display Output Status On Keypad Option Changed If the Display Output Status On Keypad option (MENU 4-1-5) has been selected, and the output in question is activated then a message will be displayed in the scroll bar. In previous versions, if you arm the panel while this massage is being displayed then the system will prompt you to force arm the output to complete the arming cycle. In the release, output status display messages are now filtered out and the panel will not consider these messages during the arming cycle. 18) PIN Always Required Option and Pop Up Boxes In Version , when the PIN Always Required option is selected, and a pop up message box is displayed, the system will prompt the user to Enter PIN + OK to acknowledge the message. In previous versions the system would prompt Press OK, however this would not acknowledge the message because no PIN had been entered. 0 Bosch Security Systems 2/06 FTR1.1 3

16 19) Turn Area On / Off Command Corrected In previous versions, the Turn Area On / Off option (MENU 2-0-1) does not filter the user to restrict them from controlling an area they don t belong to. In version the panel filters the user and only provides control for areas they are assigned to. A valid PIN is required in all cases. Areas > Commands > Turn Area On/Off -- MENU ) Domestic Reporting and Pulse Dialling In previous versions, if both the Domestic Reporting format and pulse dialling option have been selected, the system may not dial the complete phone number if it is longer than 6 digits. This is due to the amount of time it takes to dial in pulse format compared to DTMF dialling. All other reporting formats are not effected even if pulse dialling has been selected. In version , the internal dial process timer has been increased to 30 seconds which provides ample time to dial the number in pulse or decadic format. 21) Walk Testing Fire Zones In previous versions, placing a short across the EOL resistor to test a fire zone would not be accepted as a valid test and the zone would remain in the untested zone list. In version the walk testing function has been changed to allow a short across a fire zone EOL resistor to be accepted as a valid test. 23) NEW Tone Bypass Function Implemented It is often difficult to establish a remote connection to a panel if the customer picks up the phone or if a fax or answering machine answers the call before the panel does. While the ultimate solution to this problem is the use the CLI Intelliconnect method, this requires the customer to enable CLI via their telco provider. When enabled, the new Tone Bypass option (MENU 5-3-4) tells the panel to listen to every answered call and to look for a specific sequence of DTMF tones. The tone sequence will be sent by the remote programming software and when the panel recognises them, it will immediately seize the line away from the answering party and the programming session will commence. The feature requires Solution Link remote programming software version 1.03 or higher. Comms > Remote Access > Solution Link RAS Options MENU RAS Allowed Y 2 Call Back Verification Required N 3 Terminate RAS on Alarm Y 4 Answer Bypass Y 5 Answer Incoming Call Only If Armed N 6 Tone Bypass Y 7 Allow User Functions Via Remote Access Software Y 8 Report / Log RAS Start / End Sessions Y 22) RF Keyfob Panic Alarm Reporting In earlier version, panic alarms trigger via RF keyfobs would follow the status route when reporting the alarm. In domestic dialling mode, the status route would typically be disabled and this would prevent the keyfob panic for being transmitted. In version the reporting route for keyfob panic alarms has been changed to the Emergency route which would not normally be disabled when using domestic dialling. The following options are included in this release however their functionality has been disabled as they are for future use. Please ignore the following options in this release. MENU 55 - MY Alarm MENU Check Web MENU System Log MENU 508 -Register Customer MENU 509 -Register Installer Bosch Security Systems BLCC110N Issue: FTR1.1 2/06 Release Notes Solution 64

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

Safecom Solution-16 Quick Reference Guide ISSUE 1.10 Safecom Solution-16 Quick Reference Guide ISSUE 1.10 2 Solution-16 Safecom Quick Reference Guide Safecom Solution-16 Quick Reference Guide Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA8016Q

More information

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide Control Panel ICP-SOL2-P/ICP-SOL3-P en Quick Reference Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 6 2 Programming 7 2.1 ICON LCD Codepad Programming 7 2.2 TEXT LCD Codepad

More information

Bosch solution 6000 cheat sheets

Bosch solution 6000 cheat sheets Adding a token to a user Select add token and user if prompted by keypad select reader Menu 120 Select door/s that the user will have access to (if applicable) Menu 145 Select areas that the user will

More information

Solution 16 plus. User Guide Security System

Solution 16 plus. User Guide Security System Solution 16 plus EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download

More information

Solution 144 Security Systems

Solution 144 Security Systems Security Systems EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download

More information

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0 MCM Electronics MCM Electronics MCM Electronics The Icon Series Installation and Programming Information Icon 8 Version 5.0 TABLE OF CONTENTS 1. 2. 3. Panel Hardware Page 2 Physical Layout. Inputs. Outputs.

More information

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads... HWZRU;;( Control/Communicator Installation Manual Table of Contents General Description... Ordering Information... Feature Definitions... Programming the LED Keypads... Programming the NX-E...9 Types of

More information

2 IDS LCD Keypad User Manual C Issued March 2009

2 IDS LCD Keypad User Manual C Issued March 2009 2 3 4 Contents 1. Introduction to the IDS LCD Digital Keypad...8 2. Arming the Control Panel...8 2.1 Away Arming...8 2.1.1 How to Away Arm...8 2.1.2 Quick Away Arm Shortcut Key...8 2.2 Stay Arming...9

More information

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... P.2 2. STANDARD AND OPTIONAL PARTS LIST..... P.2 3. FEATURE DEFINITIONS... P.3 4. TERMINAL DRAWING AND SPECIAL

More information

Series. NX-8-EUR Control Panel. Installation manual

Series. NX-8-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-8-EUR Control Panel Installation manual NX-8-EUR Installation manual Page 2 23/12/04 CONTENTS CONTENTS...3 GENERAL INFORMATION...5 ORDERING INFORMATION...5 FEATURE DEFINITIONS...6

More information

Control Panel Solution 2000 / 3000

Control Panel Solution 2000 / 3000 Control Panel Solution 2000 / 3000 en Quick Reference Guide Control Panel Table of contents en 3 Table of contents 1 Introduction 6 2 Programming 7 2.1 Alphanumeric Codepad Menu Programming 7 2.2 ICON

More information

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

Integriti User Manual. Elite / EliteX LCD Terminal Keypads Integriti User Manual Elite / EliteX LCD Terminal Keypads INNER RANGE recommends that all INTEGRITI systems are installed & maintained by FACTORY CERTIFIED TECHNICIANS. For a list of Accredited Dealers

More information

D1260/D1260B. Owner's Manual. Keypad

D1260/D1260B. Owner's Manual. Keypad D1260/D1260B EN Owner's Manual Keypad D1260/D1260B Owner's Manual This system includes a telephone line seizure feature. The system may be programmed to communicate with a central monitoring station to

More information

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 FEATURE DEFINITIONS... 3 TERMINAL DRAWING AND SPECIAL

More information

Important Notice. Customer Information. 2 WisDom User Manual

Important Notice. Customer Information. 2 WisDom User Manual User Manual Important Notice This manual is delivered subject to the following conditions and restrictions: This manual contains proprietary information belonging to RISCO Group. The information is supplied

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

IDS.  Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2. INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002 VERSION 2.17 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm

More information

IDS X-Series User Manual E Issued June 2013

IDS X-Series User Manual E Issued June 2013 1 2 Contents 1. Introduction to the IDS X-Series Panels... 6 2. Before Operating Your Alarm System... 6 3. Understanding the Keypad LEDs... 7 3.1 Viewing Data on an LED Keypad... 11 3.2 Entering Data on

More information

Modules Programming Guide. paradox.com

Modules Programming Guide. paradox.com Keypad Modules Annunciator Module Motion Detector Modules Zone Expansion Modules Access Control Module Voice Assisted Modules Accessory Modules Integration Module Internet Module Modules Programming Guide

More information

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring

More information

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above. Please note that this manual has been prepared to highlight the new PD6662, BS8243 and EN50131-1 features. RINS1530-1 CHAPTER

More information

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup) INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

More information

VISTA-128BP/VISTA-250BP Programming Form

VISTA-128BP/VISTA-250BP Programming Form VISTA-128BP/VISTA-250BP Programming Form Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, see the Partition-Specific Fields section

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Exit

More information

Ademco Vista-20SE/First Alert FA-162C Program Sheet

Ademco Vista-20SE/First Alert FA-162C Program Sheet Enter Program 1. 4112 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #) Exit

More information

Colour Graphic Terminal User Manual. Rev 3.1

Colour Graphic Terminal User Manual. Rev 3.1 Integriti. Colour Graphic Terminal User Manual. 1 Colour Graphic Terminal User Manual. Rev 3.1 2013-2014. Inner Range Pty. Ltd. Part Number: 636000U 2 Integriti. Revision 3.1 June 2014. SYSTEM DETAILS

More information

High Security and Access System EVO48 V2.1 EVO192 V2.1

High Security and Access System EVO48 V2.1 EVO192 V2.1 High Security and Access System EVO48 V2.1 EVO192 V2.1 Programming Guide Includes LCD Keypad Programming We hope this product performs to your complete satisfaction. Should you have any questions or comments,

More information

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End RcvrAcct#: Test Date: May, ::PM SYSTEM ENTRY DELAY# [ ] = None, = secs, = secs, = secs, = secs, = secs, = mins [UL installations: The Entry Delay must be set for a maximum of seconds] ENTRY DELAY# [ ]

More information

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote... Contents 1. Introduction to the Watchguard WGAP864 LCD Digital Keypad... 6 2. Viewing Violated Zones... 6 3. Arming the Control Panel... 7 3.1 Away Arming... 7 3.1.1 How to Away Arm... 7 3.1.2 Quick Away

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

VoiceNav User Manual

VoiceNav User Manual r VoiceNav User Manual 1 Table of contents Introduction 2 Drawing 3 Glossary of terms 4 Glossary of terms continued 5 Legend 5 Warranty 5 Indicators, icons and lights 6 Away arming 7 Stay arming 8 Disarming

More information

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. S Y S T E M U S E R G U I D E SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM

More information

MG/SP Series (V4.9/V5.1) What s New

MG/SP Series (V4.9/V5.1) What s New MG/SP Series (V4.9/V5.1) What s New Firmware: SP4000 and SP5 version 5.1 SP5500, SP000, SP7000, and MG5050 version 4.9 (SP5500 pictured) Overview: New Programming Sections New Events New Trouble Display

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program (Locations 034 to 410) 1. Press Program Button on main panel 2. At keypad press 9 + Program Code (9 8 7 6 5) or 1. Power down with black switch on bottom left of panel 2. Power up while holding

More information

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

Created by: Alarm System Store   Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8 Quick Start Guide for Interlogix NetworX NX4, NX6 & NX8 Programming Code = 9713 Master User Code=1234 Program Mode= *8 + 9713 To exit programming hit the Exit key until you reach the home screen If this

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program Master Code + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and #)

More information

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup I-NXV-IM Rev F Dec 00 NetworX Series NX-V Control Panel Installation and Setup Copyright Disclaimer Trademarks and patents Copyright 00, GE Security Inc. All rights reserved. This document may not be copied

More information

PROGRAMMING HELP GUIDE

PROGRAMMING HELP GUIDE DIGIPLEX EVO48-192 PROGRAMMING HELP GUIDE Entering Programming Mode 1) Press and hold the [0] key 2) Enter your [Installer Code] (default-000000) 3) Enter 4-digit [section] you wish to program 4) Enter

More information

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18 IDS12 INSTALLER MANUAL Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Away Arm Quick Stay Arm Quick Stay Arm & Go H old down [ 1] for 1 second H old down [ 5] for 1 second H old down [ 6] for

More information

SUPERPLEX. Superplex s User s Manual Draft. Thank you for purchasing this device CONTENTS

SUPERPLEX. Superplex s User s Manual Draft. Thank you for purchasing this device CONTENTS Superplex s User s Manual Draft CONTENTS 1. Getting to know your Superplex Package List.. Basic Specifications. Appearance.. 2. Setting Up Your Superplex Power On/Off. Battery Charging Interface Port Connection

More information

Property of Monitronics Inc

Property of Monitronics Inc Enter Program 1. Master Code + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute (If exiting programming you can re-enter within 1 minute by pressing * and

More information

Control Panels D9412GV4/D7412GV4. en Owner's Manual

Control Panels D9412GV4/D7412GV4. en Owner's Manual Control Panels D9412GV4/D7412GV4 en Owner's Manual Control Panels Table of Contents en 3 Table of contents 1 Introduction 8 1.1 About documentation 9 2 Keypads overview 11 2.1 Identify your keypad style

More information

4140XMPT2 PROGRAMMING FORM

4140XMPT2 PROGRAMMING FORM 414XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown

More information

eurösec CPX Control Panel User Instructions

eurösec CPX Control Panel User Instructions eurösec CPX Control Panel User Instructions eurösec CPX User Manual Contents User Information... 2 Introduction... 3 User Code Types... 3 Setting The System... 4 Setting & Unsetting via Keyswitch... 4

More information

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2 ATLAS 8 PLUSTM USER GUIDE LED & LCD The equipment has been approved to CTR21for pan-european single terminal connection to the Public Switched Telephone Network (PSTN). However, due to differences between

More information

SigNET 200/300 User Guide

SigNET 200/300 User Guide SigNET 200/300 User Guide Warning: While this system is an advanced design integrated security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system,

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

Dialler HA2000 RTC. Installation & Operating Manual

Dialler HA2000 RTC. Installation & Operating Manual Dialler HA2000 RTC Installation & Operating Manual The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a tabletop before

More information

Installation Instructions

Installation Instructions NX-148E-RF LCD Touchpad w/receiver 466-2198 Rev. B May 2005 Product summary The NX-148E-RF Touchpad w/receiver combines touchpad and receiver capabilities into a single device for use with NetworX NX-4,

More information

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL

More information

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512 en Owner's Manual Control Panels Table of Contents en 3 Table of contents 1 Introduction 8 1.1 About documentation 9 2 Keypads overview 11 2.1 Identify

More information

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 &

Table of Contents. Phone number configuration...15 Alarm Phone numbers, 1, 2 & Divert phone numbers 1, 2 & Table of Contents Introduction... 4 Warning... 5 Warranty... 5 Glossary of terms... 6 Legend... 7 Feature & Benefits... 8 1. Phone Line connection... 8 Phone Line connection, and network connection...9

More information

SUPERPLEX. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.

SUPERPLEX. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2. SUPERPLEX User s Manual Products that work Software Release: V2.5 KE-MOBILEHQ-12- High performance, simplified wireless home security controller Thank you for purchasing this Kingdom Electronics product.

More information

First Alert FA160C/162C Installer Notes M. Leuck

First Alert FA160C/162C Installer Notes M. Leuck First Alert FA160C/162C Installer Notes M. Leuck 1. Programming can only be done by 6139 Alpha keypads, standard 6128 keypad cannot be used to program zones 2. Enter programming: Master Code + 8 + 0 +

More information

VISTA-50P VISTA-50PUL

VISTA-50P VISTA-50PUL VISTA-50P VISTA-50PUL PARTITIONED SECURITY SYSTEM with SCHEDULING Quick Start Step-by-Step Programming Procedure Single And Multiple Partition Programming Forms System Worksheets VISTA50P-PR 8/95 (See

More information

660/960 Installation Guide

660/960 Installation Guide 660/960 Installation Guide Compatible Equipment 660: Any Scantronic control panel. 960: All control panels with the Scantronic plug-on footprint pins. 496354 Issue 1 1 of 16 660/960 Introduction The 660/960

More information

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; 1 for UL. 4140XMPT2 PROGRAMMING FORM Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these fields. Standard default (*97) values are shown

More information

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel: FSK TX CELLULAR PLUS Installation and Programming Guide Tel: 0861 105 962 www.fsk.co.za INTRODUCTION The FSK TX Cellular Plus (TXC+) is a highly featured GSM based unit which is used for the transmission

More information

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE OPERATOR 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13 THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 SECTION I. CHECKING SYSTEM STATUS 3 SECTION II. USING THE MENU 4 SECTION III. ARMING YOUR SECURITY SYSTEM 5 SECTION IV.

More information

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Intelligent Security & Fire Ltd Rins 160 Issue 6

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Intelligent Security & Fire Ltd Rins 160 Issue 6 ATLAS 8 PLUSTM USER GUIDE LED & LCD 8! INSTALLER DETAI LS: 1 3 4 2 5 6 7 8 9 0 OR SET TELEPHO NE: The equipment has been approved to CTR21for pan-european single terminal connection to the Public Switched

More information

CUSTOMER INFORMATION

CUSTOMER INFORMATION CUSTOMER INFORMATION COMPANY NAME & ADDRESS: CONTACT: PHONE: FAX: NOTES: DATE ENTERED: DATE MODIFIED: 11/2/2010 12:41 P 11/2/2010 12:47 P USER_DEFINED_FIELD1: USER_DEFINED_FIELD2: Vista15PSIA-3 PROGRAMMING

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

Security System User Guide

Security System User Guide Security System User Guide Setting the System: 1. Go to the keypad and key in your access code. (Alternatively, if you have a proximity tag, present your tag to the keypad.) Either - Full Set: 2. Press

More information

SOFTWARE VERSION 3.20

SOFTWARE VERSION 3.20 48EPEP-00 SOFTWARE VERSION 3.20 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual AMAX panel AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel 4000 en Operation Manual AMAX panel Table of Contents en 3 Table of contents 1 Safety 5 2 Short information 6 2.1 Introduction

More information

ATS1190 Smart Card Reader Programming Manual

ATS1190 Smart Card Reader Programming Manual ATS1190 Smart Card Reader Programming Manual Version 2.0 Aritech and Tecom are Interlogix Companies 2001 Interlogix B.V.. All rights reserved. Interlogix B.V. grant the right to reprint this manual for

More information

SUPERPLEX 2. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2.

SUPERPLEX 2. User s Manual. High performance, simplified wireless home security controller. Products that work. Software Release: V2. SUPERPLEX 2 User s Manual Products that work Software Release: V2.0 KE-MOBILEHQ-12- High performance, simplified wireless home security controller Thank you for purchasing this Kingdom Electronics product.

More information

Clipsal HomeMinder Home Automation System

Clipsal HomeMinder Home Automation System Clipsal HomeMinder Home Automation System Part A Release 1.0.0 4 June 2000 Copyright 2000 Clipsal Integrated Systems Preface Congratulations on your purchase of HomeMinder. You now own a powerful and

More information

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1) REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1) April 01st, 2016 Identifying the Parts 1. Siren 2. Orange LED: Home Arm Key 3. Red LED: Away Arm Key 4. Panic Alarm (if enabled) - Press both 1 and 3 to

More information

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security System with Scheduling Programming Guide K0376PRV5 2/11 Rev. A Table of Contents Programming Field Settings for UL864 Compliance

More information

NetworX Series NX-8V2 Control Panel Installation and Startup

NetworX Series NX-8V2 Control Panel Installation and Startup NetworX Series NX-V Control Panel Installation and Startup 00 GE Security All rights reserved. These instructions do not purport to cover all details or variations in equipment nor to provide every possible

More information

Programming Default Tables

Programming Default Tables Lynx Plus Control Defaults Lynx Plus Series Installation and Setup Guide *20 Installer code 4112 4112 4112 4112 *21 Quick arm enable 1 1 1 1 *22 Keypad backlight timeout 0 0 0 0 *23 Forced bypass 0 0 0

More information

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING... NX-0 RELAY EXPANDER NX-0 OUTPUT EXPANDER Installation Manual GENERAL DESCRIPTION... WIRING INFORMATION FOR NX-0 AND NX-0... NX-0 TERMINAL DESCRIPTION... NX-0 DRAWING... NX-0 TERMINAL DESCRIPTION... NX-0

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 728PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

Security System. Owner s Manual

Security System. Owner s Manual Security System Owner s Manual What You Need to Know Before using this manual, you should become familiar with the Security System User s Guide. The User s Guide provides step by step instructions for

More information

ADEMCO LYNXR-ENSIA Security System

ADEMCO LYNXR-ENSIA Security System UL K5966-2 9/06 Rev. A ADEMCO LYNXR-ENSIA Security System Quick Start Guide LYNXR-ENSIA is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed.

More information

DSC PowerSeries Neo Integration

DSC PowerSeries Neo Integration DN2120-1015 DSC PowerSeries Neo Integration The purpose of this application note is to explain how to setup the DSC PowerSeries Neo integration with a KT-400 or a KT-1-M (or PCB) using an RS-232 or IP

More information

Contents USER FEATURES... 2 CAN REMOTE CONTROL BE SECURE?... 2 HOW THE SYSTEM WORKS... 2 REMOTE CONTROL BY PHONE... 3

Contents USER FEATURES... 2 CAN REMOTE CONTROL BE SECURE?... 2 HOW THE SYSTEM WORKS... 2 REMOTE CONTROL BY PHONE... 3 Contents USER FEATURES... 2 CAN REMOTE CONTROL BE SECURE?... 2 HOW THE SYSTEM WORKS... 2 REMOTE CONTROL BY PHONE... 3 1. GENERAL RULES FOR REMOTE CONTROL VIA SMS INSTRUCTIONS... 3 2. SETTING (ARMING) BY

More information

Wireless Alarm System User Guide

Wireless Alarm System User Guide Wireless Alarm System User Guide Alarm Panel Time 10:09 c RINS1902 Document SAP: 102015108-03 Contents ProControl+ 4 Setting Devices 5 The Wireless Panel Keypad 5 Wireless Keyfobs 5 Locking the Keyfob

More information

Digiplex EVO High Security and Access System What s New EVO192 V2.7

Digiplex EVO High Security and Access System What s New EVO192 V2.7 Digiplex EVO High Security and Access System What s New EVO192 V2.7 Overview New zone programming and additional zone/system/anti-mask options EN 50131 compliancy Now supports automatic label broadcast

More information

Ademco/Protection One 250P1-1 Programming Form

Ademco/Protection One 250P1-1 Programming Form Ademco/Protection One 250P1-1 Programming Form Local programming requires the use of a 2-line Alpha keypad connected to the keypad terminals on the control. Field Function Programmed Values [ ] = Default

More information

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

VISTA-20SEa. 3-Partition Security System. Programming Form.   V20SEaPRV1 9/98 VISTA-20SEa 3-Partition Security System New style cover to be used Programming Form V20SEaPRV1 9/98 Local programming requires the use of a 2-line Alpha keypad connected to Partition 1 keypad terminals

More information

The Icon Series. Icon 16, Icon 32, Icon 48. Installation and Programming Information. MCM Electronics MCM Electronics MCM Electronics

The Icon Series. Icon 16, Icon 32, Icon 48. Installation and Programming Information. MCM Electronics MCM Electronics MCM Electronics MCM Electronics MCM Electronics MCM Electronics The Icon Series Icon 16, Icon 32, Icon 48 Installation and Programming Information Version 4.5 and 5.0 Icon1648-010999.pm6 Index 1. Inputs. 2. Outputs.

More information

Programming Worksheets

Programming Worksheets Now classified in accordance with ANSI/SIA CP-01-2000 (SIA-FAR) Programming Worksheets PC1555 CP-01 PC1555 CP-01 version 3.2 DLS2002 and higher Page references below are to the accompanying Installation

More information

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

Emergency Dialer DIAL-ALERT MODEL: AD-433S. www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-433S 101A118 FEB, 2000 SKYLINK TECHNOLOGIES INC., 2213 Dunwin Drive, Mississauga, Ontario L5L 1X1 CANADA Tel : (905) 608-9223 (800) 304-1187

More information

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011 LX8 emfone Installation and Configuration TVL No. 336 Issue No. 1 03/10/2011 Thames Valley Controls Unit 15 Manor Farm Industrial Estate Flint Flintshire CH6 5UY T: +44 (0) 1352 793222 F: +44 (0) 1352

More information

NX-2192E PINPOINT SYSTEM

NX-2192E PINPOINT SYSTEM NX-9E PINPOINT SYSTEM INSTALLATION MANUAL TABLE OF CONTENTS. GENERAL DESCRIPTION.... INSTALLATION.... DEVICE ADDRESS CONFIGURATION.... TERMINAL DESCRIPTIONS.... WIRING DIAGRAM.... MAXIMUM NUMBER OF DEVICES

More information

Emergency Dialer DIAL-ALERT MODEL: AD-105.

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :

More information

Challenger Series Administrators Manual

Challenger Series Administrators Manual Challenger Series Administrators Manual P/N MAADMN-TS1016 REV 07 ISS 20AUG15 Copyright Trademarks and patents Manufacturer Agency compliance Contact information 2015 UTC Fire & Security Australia Pty Ltd.

More information

CONCEPT 3000/Access 4000 User Manual UK Supplement

CONCEPT 3000/Access 4000 User Manual UK Supplement CONCEPT 3OOO & Access 4000. 1 CONCEPT 3000/Access 4000 User Manual UK Supplement Revision 5.70 This manual is intended for use in conjunction with the Concept 4000 User Manual, Revision 5.6 or later. CONTENTS

More information

Telephone and Reporting Setup in ElkRP

Telephone and Reporting Setup in ElkRP Telephone and Reporting Setup in ElkRP 1. To add a telephone, right click on Telephones under Folder items on the left side of the screen. Then select New Telephone. 2. On the New Telephone IDs screen,

More information

Modules Programming Guide

Modules Programming Guide Modules Programming Guide Programming Methods The modules can be programmed using the following methods: 1) Through the WinLoad Security Management Software. The modules can be programmed at 19,200 baud

More information

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement

* * ARM MONITOR EXCLUDE MEMORY. HomeSafe Security Panel 5400/16CB. Programming Manual C-Bus Supplement * * ARM 1 2 3 MONITOR 4 5 6 EXCLUDE 7 8 9 MEMORY P 0 E HomeSafe Security Panel 5400/16CB Programming Manual C-Bus Supplement Contents 1.0 Product Range...3 2.0 Features...3 2.1 Control Panel Features...3

More information

EC-11 Ethernet Converter

EC-11 Ethernet Converter EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...

More information

DSC programming for the Alexor and Impassa

DSC programming for the Alexor and Impassa DSC programming for the Alexor and Impassa THERE IS NO REASON TO BE IN ANY SECTION OF YOUR SYSTEM UNLESS IT IS ON THIS QUICK START GUIDE. If you do not see it here, please question if you should be doing

More information

NX-148 LCD KEYPAD INSTALLATION MANUAL

NX-148 LCD KEYPAD INSTALLATION MANUAL NX-148 LCD KEYPAD INSTALLATION MANUAL Table of Contents Entering the Program Mode... 2 Selecting the Module to Program... 2 Programming a Location... 2 NX-148 Library... 3 Loading Factory Defaults... 3

More information

Agility Installation Quick Start Guide 1

Agility Installation Quick Start Guide 1 Agility Installation Quick Start Guide Thank you for purchasing the Agility Flexible Wireless Solution from RISCO Group. This quick start guide will describe the main steps for installing and programming

More information

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER: CMP-DF2V1 7/01 Security Services SALES REPS: PLEASE FILL IN ALL WHITE AREAS. FOCUS 200 PLUS A CUSTOMER SYSTEM INVENTORY AND DATA ENTRY FORMS CCC #: _ / / _ / CUSTOMER CONTROL UNIT TELEPHONE NUMBER: ( _

More information

ELECTRONIC ENGINEERING LTD. OLED Keypad. User s Guide. P/N: Doc Rev-A SW Ver /08/10

ELECTRONIC ENGINEERING LTD. OLED Keypad. User s Guide. P/N: Doc Rev-A SW Ver /08/10 ELECTRONIC ENGINEERING LTD. OLED Keypad User s Guide P/N: 7103670 Doc Rev-A SW Ver-0.65 05/08/10 Crow Limited Warranty Crow warrants this product to be free from defects in materials and workmanship under

More information