HCC-CW-201A. CWDM Analyzer. Operation Guide
|
|
- Rosaline Griffith
- 5 years ago
- Views:
Transcription
1 CWDM Analyzer Operation Guide
2 Table of Contents Description... 3 Features... 3 Specifications... 4 Safety Information... 5 Preparing for Operation... 6 Unpacking the instrument... 6 Front keys definition... 6 Rear panel definition... 7 Function Modules Description of functions Menu Mode CWDM Parameters / CWDM Parameter setting Back light setting Time setting OPM Parameters/OPM setting View History Auto off Name File Name Open File About Warranty
3 Description HCC-CW-201A Handheld CWDM Analyzer is specially designed for CWDM installation, maintenance and troubleshooting, which is able to measure and monitor power values of 10 CWDM channels. HCC-CW-201A can replace high-cost Spectrometers and conduct quick and reliable measurements in all environments. Thanks for its light, compact and sturdy design, HCC-CW-201A is the ideal tool for CWDM installation and maintenance technicians. Features: Hand-held, more compact and easy to operate TFT LCD display Inner timing system Threshold configuration: can preset threshold value 10CH wavelength testing: 1431nm-1611nm Data Transfer to PC via USB Histogram or list data display modes Back light function Can work as the normal power meter 10 hours continuous work data storage & download Result display in histogram and list straight forward result display for easy understanding Histogram mode X axis represents the channels 1-10 from 1431nm to 1611 nm. Y axis represents the power value (dbm). The red value of channel number represents cannot get through the threshold value. List mode 10 Channels list 3 kinds of unit: mw / uw / dbm / db (REF). The red value represents failure to pass. General Power Meter There are six wavelengths 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm
4 Specifications Wavelength (nm) 1431 ~ 1611 Power Range (dbm) -40 ~ +10 Channel Number 10 Channel Spacing Central Wavelength Channel Band-pass Channel Power Resolution Channel Power Accuracy Maximum Input Power Return Loss Close Channels Insulation Non-close Channels Insulation Units of Measurement Data Storage Connector 20nm ITU ITU ±6.5nm ±0.01 db ±0.5 db 13 dbm >45 db 25 db 30 db mw/uw/db (REF) 1,000 Operations FC/PC (Interchangeable SC, ST) Power Meter Calibrated Wavelengths (nm) 850, 1300, 1310, 1490, 1550, 1625 Power Range (dbm) -60 ~ +10 Unit mw/uw/nw/dbm/db (REF) Resolution ±0.25 db 25 ºC General Power Supply Battery Capacity NiMH Rechargeable Battery / AC Adaptor Continuous Operation 10 Hours Operating Temperature 32º F ~ 122º F (0º C ~ 50º C) Environmental Conditions 0 ~ 95% (Humidity) Weight & Dimensions(HxWxD) 7.5 x 4 x 2 / 1.5 lbs. (191 x 102 x 51 mm / 680 g)
5 Safety Information Warnings! Never look directly into optical outputs or a fiber while the equipment is on because invisible laser radiation may damage your eyes. Do not short-circuit the terminal of AC adapter, charger or the batteries. Excessive electrical current may cause personal injury due to fumes, electric shock or equipment damage. Connect AC power cord with the equipment and wall socket properly. While inserting the AC plug, make sure there is no dust or dirt on the terminals and both plugs are fully seated. Incomplete engagement may cause fuming, electric shock or equipment damage and may result in personal injury. Do not operate the equipment near hot objects, in hot environments, in dusty/ humid atmosphere or when condensation is present on the equipment. This may result in electric shock, product malfunction or poor performance. Discharged batteries Remarks: 1) When the battery power is almost out, there will be a warning of indicator keeps blinking, then please replace the batteries or plug in AC adapter to charge batteries. 2) Please make sure that you have turned the instrument on before charge the batteries, unplug the AC adapter when the batteries are fully charged. 3) Please make sure the batteries are well placed before charging them. 4) To eliminate the possibility of acid leakage, please take out the batteries if the unit will not be used for a long time. AC operation If the instrument is mainly used at one location, e.g. in a laboratory or test department, the AC adapter can be used to power it instead of batteries. There is a DC input jack on the left side of the HCC-CW-201A instrument casing into which the output cable of the AC adapter is plugged. And when the AC adapter is plugged in, the AC Indicator on the LCD will be displayed. Note: 1) Power is supplied by the AC adapter even if battery is fitted. And the battery indicator is not displayed on the screen when AC adapter is plugged. 2) Make sure that the operating voltage of the AC Adapter/Charger is the same as the local AC line voltage
6 Preparing for Operation Unpacking the instrument Packing material We suggest that you keep the original packing material. Using the original packing material is your guarantee of protecting the instrument during transit. Checking the package contents The standard accessories of HCC-CW-201A are as follows: Main unit Quality Check Report Carrying Case User's Guide 4*Ni-MH Batteries Checking for damage in transit After unpacking the instrument, check to see whether it was damaged in transit. This is particularly likely if the outer casing is clearly damaged. If there is damage, do not attempt to operate the instrument or to repair it without authorization. Doing so can cause further damage and you may lose your warranty qualification. Front keys definition ON/OFF key ; Long press for 2-5 seconds to turn on the meter Menu key; Testing mode, press to go into the menu; Menu mode, Press to get back to the former menu Units switch key ;CWDM mode, press to switch the units dbm/db/mw ; OPM mode, press to switch the wavelengths Save key; Save the important data of CWDM values Direction selecting key Insertion key
7 Rear panel definition 1 9V Power adaptor interface 2 USB Interface 3 OPM Interface 4 CWDM Interface 5 Battery Auto power off. You can set the function through the menu Internal clock. Display the real time Adaptor connection display The margin of battery The series number of fiber The name of saved data
8 Function Operation Interface ON/OFF Press to turn on or off the meter The starting interface is CWDM testing mode to Power meter function display the dbm value. Press to switch the units: dbm/db/mw; Press left/right key to switch among the CWDM value list, histogram figure, OPM power value. Save CWDM value You can save the power value of CWDM according to your requirement. Menu With testing mode, press to get into the menu mode. Press it again back to the former menu or testing mode. With menu mode, configuration. Press wavelength; to get into the CWDM to switch the CWDM Parameters Press up/down keys to set threshold value, refer value, and rectify value; Then to save the configuration Press former menu. to go back to the Back light In menu mode, to get into the backlight setting. Press up/down keys to adjust the brightness of backlight. After the setting, press to exit menu
9 Time In the menu mode, press setting mode and press time setting, please press configuration, press to go into the time to set the time. After to save the to exit the menu. In the menu mode, press to set the OPM OPM Parameters parameters. Press to change the wavelength and press up/down key to set reference value, rectify value. After setting, press to save the configuration. to exit the menu. View History Check the saved data Auto off In menu mode, press to open or close this function. Create a new file New File Open or delete the saved file Open File About In the menu mode, to display the related information
10 Function Modules: Two modes: Testing Mode and Menu Mode The testing mode includes CWDM power meter, OPM power meter mode. Menu mode includes the following 9 items. 1) CWDM Parameters 2) Back light 3) Time 4) OPM Parameters 5) View History 6) Auto off 7) New File 8) Open File 9) About After boot-up, the meter automatically displays the testing mode. As shown in Fig. 2, in the testing mode, press to get into the menu mode. Press to choose the needed menu. The chosen menu is in the red color, as shown in Fig. 3. Fig 2 Fig
11 Description of functions Auto power off Auto power off function is that no operation for 10 mins, it will auto power off. In the menu mode, press to: choose auto off mode, press to open or close this function. CWDM power meter mode: 10 channels CWDM power display. Press to choose the power unit: dbm/ db/ mw. If it displays "LOW" or "HIGH, the value exceeds the testing range. If the NO is red, the value is beyond the threshold value. For the detail information, you need to check the CWDM parameter setting. Fig 4 Fig 5 Fig 6 Save the CWDM value You can save the CWDM values according to your requirement. Choose the CWDM display mode: List mode / Histogram mode / General power meter After boot-up, it will display the CWDM power mode. Press 6, 7, 8. to choose the display mode. As shown in Fig. Fig 6 Fig 7 Fig
12 Save the CWDM value As it is shown in Fig. 9, in the OPM mode, Press up/down keys to choose the needed wavelength: 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm. It will display the power of the real wavelength in dbm/ db/mw. If it displays "LOW" or "HIGH, it exceeded the testing range. Menu Mode As is shown in Fig. 12, in the testing mode, please press to get into the menu mode. You can press to choose the menu you need. The chosen item will display red. CWDM Parameters / CWDM Parameter setting CWDM parameter setting includes three items: Threshold setting, reference value setting, rectifies value setting. Threshold setting: Compare the testing power value with the threshold values and identifies it by the display color (Red represents failure; blue represents pass). The function make testing is so direct viewing that it can be used in some special requirement areas. The function is suitable in some special areas. The testing range is -30dBm +20dBm. So the minimum threshold should >-30dBm and the maximum threshold should <+20dBm (- 30<Threshold Min<Threshold Max<+20). If the "P" represents the real power: 1) P<-30, it will display "Low" and the CH No is red. 2) -30<P<Threshold Min, it will display the power value and be in red color. 3) Threshold Min<P<Threshold Max, it will display the normal power value. 4) Threshold Max<P<+20, it will display the power value and be in red color. 5) P> +20, it will display" HIGH" and the CH No is red. As it is shown in Fig. 11, the NO 1, 2, 7 power is beyond the set threshold. As it is shown in Fig.12, the NO 1, 2, 4, 6 channels is beyond the set threshold. Fig 10 Fig 11 Fig
13 Reference value setting: Take the dbm as the unit and it will display the real value of power; Take db as the unit and it will display a reference value according to the saved reference value. Reference value: Display value=testing value Reference value Rectify value setting: the original value is zero. Please set the rectify value according to your requirement. Operation is as follows: As shown in Fig.13, 14, after entering the CWDM parameter setting menu, press wavelengths among the 10 wavelengths. Press to switch the right/left keys to move the cursor to the designated position. Then press up/down keys to set the parameters. Press to save the setting. Press to exit the menu. Fig 13 Fig 14 Back light setting Move to the back light setting menu, as is shown in Fig.15, press up/down keys to adjust the intensity of the back light. Press to exit the menu. Fig 15 Time setting Get into the time setting menu, as is shown in Fig. 16. Press left/right to move cursor to the designated position; Press up/down keys to set the time. After setting, press to save the setting. Then press to exit the time setting
14 Fig 16 OPM Parameters/OPM setting Reference value setting: Take the dbm as the unit and it will display the real value of power; Take db as the unit and it will display a reference value according to the saved reference value. Reference value: Display value =Testing value, Reference value Rectify value setting: The original value is zero. Please set the rectify value according to your requirement. As is shown in Fig. 17, 18, after entering the OPM setting menu, press switch the 6 wavelengths; Press left/right to move cursor to the designated menu; Press up/down to adjust the value. After setting, press to save the current value. Press to exit the menu. View History Fig 17 Fig 18 In the "Open File" menu, choose the needed file, then get into the testing mode; to get into the menu mode; choose View History menu it will display the latest saved power value, as is shown in Fig.19, 20. Press up key to refer the last one. Press down key to display next one. Press to back to the View History menu. Fig 19 Fig
15 Auto off As is shown in Fig.21, after choosing Auto off menu, press to open/close this function. Name File Name Fig 21 Get into the New file menu, as is shown in Fig. 22, press left/right to move cursor to the designated position; Press up/down keys to write the file name ; Press to save the file, in the meanwhile the screen will flash "Save File!" for one second. If you create the same name as the former file, the screen will flash "The Saved File!" for one second. You need to rewrite the file name to save. Note: The maximum number of files is 8. Fig 22 Open File As shown in Fig. 23, get into the Open File menu; Press up/down keys to the designated file; The chosen file is in orange color; Press left/right keys to open or delete the file; The chosen file is in blue color. Delete file: When the Delete is in blue color, press to delete the file. Open file: "Open" is in blue color; Press to get into the testing mode; Press to get into the menu mode; choose the "View History" menu, then press to open the chosen file. Fig
16 Note: As shown in Fig. 24, 25, if you need to save a series of CWDM power value into a file. Firstly you need to create a file or open the existing file, then in the testing mode, press to check the CWDM values dbm/db/mw. Press to save the value. It can save one hundred testing values. About Fig 24 Fig 25 After entering the About menu, press 8 to check the version information. Daily Maintenance: 1) Shut down the power in time after using the meter. Cover the fiber connector protection cap and put it in a ventilation dry place. 2) Clean the fiber connectors regularly, keep the optical channel clean. 3) Calibrate the meter once a year to assure the testing accuracy. 4) Pick the battery out if there is a long period of no operation. 5) Don't disassemble the instrument by yourself; it could result in a permanent damage and loss of the maintenance qualification
17 Warranty Three Years Limited Warranty Precision Rated Optics products are warranted against the defective components and workmanship for a period of three years from the date of delivery to the original customer. Any product found to be defective within the warranty period would be returned to Precision Rated Optics authorized service center for repair, replacement and calibration. Exclusions The warranty on your equipment shall not apply to defects resulting from the following: Unauthorized repair or modification Misuse, negligence, or accident Returning Product To return product, you may contact Precision Rated Optics to obtain additional information if necessary. To serve you better, please specify the reasons for the return. All delivery and mails should be sent to the following address: 9999 Hamilton Blvd Breinigsville, PA
18 Precision Rated Optics, Inc. Corporate Office Billing & Processing PO Box 877 Trexlertown, PA Precision Rated Optics, Inc. Product Distribution Center Manufacturing & Testing 9999 Hamilton Blvd Breinigsville, PA 18031
PM-204A/B. Power Meter. Operation Guide
Power Meter Operation Guide Contents 1. Introduction...3 2. Warranty...3 3. Safety Information...3 4. Preparing for Operation...4 4.1. Unpacking the instrument...4 4.2. Discharged batteries...4 4.3. AC
More informationPM-100 SERIES. Operation Guide. Power Meter V
PM-100 SERIES Power Meter Operation Guide V5.27.16 Contents 1 Introduction...2 2 Warranty...2 3 Safety Information...3 4 Preparing for Operation...3 4.1 Unpacking the instrument...3 4.2 Discharged batteries...3
More informationPPM-30 PON Power Meter. User s Manual. Shineway Technologies, Inc. All rights reserved.
PPM-30 PON Power Meter User s Manual Shineway Technologies, Inc. All rights reserved. PPM-30 PON Power Meter Safety Instructions Safety Terms Used in This Manual WARNING identifies any procedure or practice
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications
More informationKI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter
User Manual KI6501 series Optical CWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher
More informationKI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter
User Manual KI6503 series 48-Channel Optical DWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against
More informationAQ2170 Optical Power Meter
User s Manual AQ270 Optical Power Meter User s Manual Yokogawa Meters & Instruments Corporation IM AQ270-0EN st Edition Notes. The contents of this manual are subject to change without prior notice as
More informationOperation Manual for OPM-1315 Optical Power Meter
Operation Manual for OPM-1315 Optical Power Meter www.tonercable.com Table of Contents 1. Introduction... 1,2 1.1 Summary... 1 1.2 Product Features... 2 1.3 Technical Parameters... 2 1.4 Main Applications...
More informationFIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual
FIBER WP-TEST-FIBER-400 Optical Power Meter Owner s Manual Technical Support: p. 866.838.5052 2017 Wirepath Ver. 170419-1000 Contents Chapter 1. Standard Configuration... 2 Chapter 2. Overview... 2 Chapter
More informationRA3301Optical Multimeter
RA3301Optical Multimeter 1.Overview Handheld Optical multimeter is for the installation, operation and maintenance of a fiber optic network designed accurate, durable and portable instrumentation. It is
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide Warranty All NOYES test equipment products are warranted for a period of (1) one year from the
More informationOptical Power Meter MT-7603
Optical Power Meter English USER'S GUIDE Optical Power Meter English WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate
More informationHandheld Optical Power Meter. Model SSF-TKITP-400 OPTICAL POWER METER. Manual
Model SSF-TKITP-400 OPTICAL POWER METER Manual August 2016 Contents Chapter 1. Standard Configuration.....2 Chapter 2. Overview...........2 Chapter 3. Data Sheet.....3 Chapter 4. Function.........4 4.1
More informationFTE-6000 Hand Held Tuneable Laser Source
FTE-6000 Hand Held Tuneable Laser Source USER S MANUAL Avoid Exposure Laser Radiation Emitted From The Aperture This product conforms to CDRH standards for laser product Per 21 CFR 1040.10 & 1040.11 Table
More informationOPM-50 Optical Power Meter User s Manual
OPM-50 Optical Power Meter User s Manual Shineway Technologies, Inc. All rights reserved. 0BSafety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like,
More informationUser's Guide. Mini Microscope. Model MC108
User's Guide Mini Microscope Model MC108 Introduction Congratulations on your purchase of this Extech Meter. This digital microscope with 7 to 27X optical magnification, 4X digital zoom, image capture
More informationUSER MANUAL FOT-PM Optical Power Meter
USER MANUAL FOT-PM Optical Power Meter CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu, Taipei 114 Taiwan Tel: +886-2-26591021
More informationOperation Manual for OLS-1315 Optical Light Source
Operation Manual for OLS-1315 Optical Light Source www.tonercable.com Table of Contents 1. Introduction... 1,2 1.1 Summary... 1 1.2 Product Features... 2 1.3 Technical Parameters... 2 1.4 Main Applications...
More informationPON Optical power meter USER'S GUIDE
PON Optical power meter USER'S GUIDE English WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate this equipment. To reduce
More informationHandheld Video Microscope
Handheld Video Microscope SAFETY SUMMARY Personnel concerned with the operation of this instrument must thoroughly understand and follow the safety guidelines below. The manufacturer assumes no liability
More informationOptical CWDM Power Meter
User Manual Optical CWDM Power Meter TheFibers Inc. A-1109 Keumkang Penterium IT Tower, 282 Hagui-ro, Dongan-gu, Anyang-City, Korea Tel: +82-31-381-6108 Fax: +82-31-381-6109 Email: sales@thefibers.com
More informationFlexScan OTDR With SmartAuto and LinkMap
FlexScan OTDR With SmartAuto and LinkMap User s Guide Test & Inspection Contents Safety Information...5 Hardware Overview...7 Controls, Display, Interfaces...7 Front Panel Buttons and Indicators...9 Battery
More informationRA3211 PON optical power meter
1. Overview RA3211 PON optical power meter is a tester designed for design, operation and maintenance of FTTX network. It is able to concurrently measure the optical power values of voice, data and video
More informationUser Manual. Optical DWDM Power Meter ODPM-48
User Manual Optical DWDM Power Meter TheFibers Inc. A-1109 Keumkang Penterium IT Tower, 282 Hagui-ro, Dongan-gu, Anyang-City, Korea Tel: +82-31-381-6108 Fax: +82-31-381-6109 Email: sales@thefibers.com
More informationTC100 Precision Thermocouple Calibrator
TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6
More informationVIP-55. Operation Guide. Video Inspection Probe V
Video Inspection Probe V.9.6.17 Operation Guide Table of Contents 1. VIP-55 Video Inspection Probe...3 FB Connect...4 2. Highlights...4 3. APP installation and use...5 App installation...5 4. USB Cable
More informationFOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide
Test & Inspection FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Table of Contents Safety Information....3 How to View Device
More informationInstruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,
4411H-English_Manuals 3/11/11 1:13 PM Page 1 Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos. 40-6526, 40-6529, 40-6544 Instruction Manual Congratulations on your choice of
More information10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan
10G SFP+ Checker Page 1 of 9 Copyright 2012, reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features..... 3 2. Specification..... 4 3. Element & Operating
More informationCSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide
CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Limited Warranty All NOYES test equipment products
More informationOptical Power Meter With VFL. User Manual
With VFL User Manual Contents 1. Summary...1 2. Functions...2 3. Specifications...3 4. Layout...4 5. Operation...5 6. Maintenance...9 7. Charge battery...9 8. Faults & Solutions...10 9. Software...10 1
More informationMT-7610 Optical Time Domain Reflectometer USER'S GUIDE
MT-7610 Optical Time Domain Reflectometer USER'S GUIDE English Test Equipment Depot - 800.517.8431-99 Washington Street - Melrose, MA 02176 TestEquipmentDepot.com AVOD EYE OR SKIN EXPOSURE TO DIRECT OR
More informationTechnical Specification. for. 10 Gbps SFP+ Checker
Technical Specification for 10 Gbps SFP+ Checker Contents 1. General Description...1 2. Features...1 3. Applications...2 4. Specification...2 5. Elements & Operating Instructions...3 6. Maintenance...5
More informationOptical Time Domain Reflectometer USER'S GUIDE
Optical Time Domain Reflectometer USER'S GUIDE AVOD EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION AVOD EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION WARNING You are cautioned that changes
More informationAE3100 Series User Manual. Version 1.02
AE3100 Series User Manual Version 1.02 Preface Thanks for purchasing the AE3100 series OTDR (Optical Time Domain Reflectometer). This manual contains useful information about AE3100 series OTDR s functions
More informationTable of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...
General Warranty OWON warrants that the product will be free from defects in materials and workmanship for a period of 2 years (1 year for accessories) from the date of purchase of the product by the original
More informationOTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL
OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com www.olsontech.com 025-000521 Rev. X1 10/01/2012 SAFETY WARNINGS LASER
More informationPV Remote Unit A 1378 Instruction manual Version 2.1, Code no
PV Remote Unit A 1378 Instruction manual Version 2.1, Code no. 20 752 010 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul Slovenia web site: http://www.metrel.si e-mail: metrel@metrel.si
More informationUser's Manual Sound Level Alert Model SL130
User's Manual Sound Level Alert Model SL130 Meets ANSI and IEC Type 2 Sound Level Meter Standards Settable High Limit with large bright High/Low indication and Alarm Output Wall or Desk mountable Extra
More informationUSER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power
Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland
More informationInstruction Manual RS-1660
Instruction Manual RS-1660 Transformer Turns Ratio Meter This unit passes the following tests: Safety Symbols EN 61010-1: 2010 EN 61010-2-030: 2010 CAT IV 50V Pollution Degree 2 EN 61326-1: 2013 (CISPR
More informationHandheld Laser Particle Counter. Model: P311. Operation Manual. Ver: 1.50 AIRY TECHNOLOGY INC
Handheld Laser Particle Counter Model: P311 Operation Manual Ver: 1.5 AIRY TECHNOLOGY INC 1 Warranty AIRY TECHNOLOGY INC warrants to the original user that this instrument shall be free from defects in
More informationLED-Illumination with Control Unit Ident.-No
A HAAG-STREIT COMPANY MÖLLER-WEDEL OPTICAL GmbH, Rosengarten 10, D-22880 Wedel with Control Unit Ident.-No. 773 190 01 Valid from Hardware / Software Rev. / SN 1.0 IDENT.-NO. 217 321 09 Document Version
More informationFT-20 Fire Training Fog Machine User Manual English
FT-20 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating
More informationOTS-400 Series Optical Meters, Sources and Testers A LANscape Solutions Product
OTSK-4MDSD Specs Provided by www.aaatesters.com OTS-400 Series Applications Installation, testing and troubleshooting of LAN, telco, CATV and FTTx networks Description The OTS-400 Series of intelligent
More informationHuddlePod Air DUO Dual Wireless Audio Pods Installation and Operation Manual
HuddlePod Air DUO Dual Wireless Audio Pods Installation and Operation Manual Please visit www.huddlecamhd.com/ for the most up to date version of this manual Precautions Safety Tips Please be aware any
More informationAQ2180 Optical Power Meter
User s Manual AQ2180 Optical Power Meter User s Manual Yokogawa Meters & Instruments Corporation IM AQ2180-01EN 1st Edition Notes 1. The contents of this manual are subject to change without prior notice
More informationAirborne Particle Counter
985 Airborne Particle Counter Getting Started PN 4136462 March 2012 2012 Fluke Corporation. All rights reserved. Printed in U.S.A. Specifications are subject to change without notice. All product names
More informationOperating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level
Operating Manual AdirPro HV8RL Red Beam Horizontal/Vertical Laser level Maintenance and Safety The HV8RL is a class II laser according to 21CFR1040. Be careful not to expose your eyes to the laser beam.
More informationUser Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2
User Manual 4K HDMI Splitter 1x4 All Rights Reserved Version: SHSP14_2016V2 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save
More informationLBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM
LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability
More informationAF-OLK5A Series Fiber Optic Test kit
AF-OLK5A Series Fiber Optic Test kit Description The AF-OLK5A series test kits are the complete solution necessary for the installer to test, terminate and trouble shoot fiber optic systems. These test
More informationSCT2000 and SCT1500 Structured Cable Testers
SCT2000 and SCT1500 Structured Cable Testers USER MANUAL ENGLISH 1 SAFETY WARNINGS Read First: Safety and Operational Information The international symbols used on the instrument or in this manual are
More informationOTS-400 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities A LANscape Solutions Product
Applications Testing and troubleshooting of various telecommunication networks Description The Corning Cable Systems OTS-400 Series of intelligent and versatile optical meters, sources and testers offers
More informationBENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL
BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...
More informationVIP-45-WIFI. Operation Guide. Video Inspection Probe V *VIP-45 Probe Not Included With Wi-Fi Module
Video Inspection Probe *VIP-45 Probe Not Included With Wi-Fi Module Operation Guide V.04.27.17 Foreword Thank you for purchasing from PRECISION RATED OPTICS. Before assembly and use, make certain that
More informationPrecise Fiber Couple Laser Light Source
Precise Fiber Couple Laser Light Source User Guide User Guide Document No. AEO-LD1480-0001 1. SAFTEY REQUIREMENT... 2 Precise Laser Light Source Page 1 / 15 1.1 User esponsibility...3 2. Description..
More informationEPS Power Supply
EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------
More informationOTEB-CO-B Series. Booster EDFA OPERATING MANUAL
OTEB-CO-B Series Booster EDFA OPERATING MANUAL 24926 Highway 108 Sierra Village, CA 95346 Phone: (800) 545-1022 Fax: (209 586-1022 025-000533 Rev X6 E-Mail: sales@olsontech.com 27 Apr 2010 TABLE OF CONTENTS
More informationOperation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.
Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1
More informationInstallation and Operation Back-UPS Pro BR700G-TW
Installation and Operation Back-UPS Pro BR700G-TW Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Do not connect a laser printer or hair
More informationFT-20 Fire Training Fog Machine User Manual English
FT-20 Fire Training Fog Machine User Manual English 2017 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating
More informationUser Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size
User Manual 1U LCD Keyboard Drawer KwikDraw - A Series - With KVM options - 15", 17, 19 screen size 1.1 Important Safeguards Please read all of these instructions carefully before you use the device. Save
More informationUser Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series
User Manual RKD-KVM-20 / RKDS-KVM-20 Series - 1U 20" LCD keyboard drawer - Resolution up to 1600 x 1200 - Full range KVM options WRKD-KVM-19 / WRKDS-KVM-19 Series - 1U widescreen 19" LCD keyboard drawer
More informationManometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,
Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI 840080, 840081, 840082 840083, 840085 Manometers 840080, 840081, 840082, 840083, 840085 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the
More informationPM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL
PM-212-SI3 Pocket Optical Power Meter INSTRUCTION MANUAL Revision 2.4 is the registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective
More informationPM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL
PM-212-MPO Pocket Optical Power Meter INSTRUCTION MANUAL Revision 1.2 is the registered trademark of OPTOKON, a.s. Other names and trademarks mentioned herein may be the trademarks of their respective
More informationC2000 POWER METER With Data Storage
C2000 POWER METER With Data Storage Operation Instructions CONTENT 1. Features 2. Functions 3. Operation 4. Specification 2 1. Features The Appointech C2000 handheld power meter has calibrated readings
More informationUSER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:
USER MANUAL DV-HAS HDMI Audio Separator 244 Bergen Boulevard, Woodland Park, NJ 07424 Tel 973-785-4347 FAX 973-785-3318 Web: www.fsrinc.com LIT1460 Proprietary Information All information in this manual
More informationModel OI-9100 Signal Strength Meter The View
Model OI-9100 Signal Strength Meter The View Operation Manual Revision 1.1 2 Product Overview The WireFree Gen II View OI-9100 is a hand held signal strength meter specifically engineered to show the status
More informationTrue RMS AC Voltage/Current Datalogger
User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long
More informationOPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM
OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF
More informationLDM M LASER DISTANCE MEASURER
LDM120 120M LASER DISTANCE MEASURER INSTRUCTION MANUAL SAFETY Read the following safety instructions before attempting to operate this product. SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE.!
More informationDatalogging Conductivity/ TDS Meter. Instruction Manual
Datalogging Conductivity/ TDS Meter 850039 Instruction Manual 1 TABLE OF CONTENTS 1. INTRODUCTION...3 2. PANEL DESCRIPTION...4 3. MEASURING PROCEDURE...5 3-A General Measurement...5 3-B Auto and Manual
More informationOLP-55 Sm a r t Optical Power Meter A Sm a r t, Future-Proof Optical Power Meter
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS OLP-55 Sm a r t Optical Power Meter A Sm a r t, Future-Proof Optical Power Meter Key features Industry s first auto-zeroing function provides outstanding accuracy
More informationSmartPocket Optical Power Meter OLP-34/35/38
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS SmartPocket Optical Power Meter OLP-34/35/38 Key features Cost-effective, rugged and high performance solution 3 year recalibration period Universal wavelength
More information1-36V, 0-3A DC Power Supply
1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,
More informationVIAVI. OLA-54 and OLA-55. SmartClass. Data Sheet. Optical Level Attenuator. VIAVI SmartClass optical handhelds go beyond the basics.
Data Sheet VIAVI TM SmartClass Optical Level Attenuator OLA-54 and OLA-55 VIAVI Solutions VIAVI SmartClass optical handhelds go beyond the basics With more than 100,000 optical handhelds already in use,
More informationIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation
More informationAOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE
AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate this equipment.
More informationSHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual
FG-7000T Digital Torque Gauge Operation Manual SHIMPO INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the
More informationAudio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2
Audio DVI 3GSDI ELR Lite Embedder Extender over one CAT-5 EXT-DVI-1CAT5-SR User Manual Release A2 DVI ELR Lite Extender over one CAT-5 Important Safety Instructions 1. Read these instructions. 2. Keep
More informationUser Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0
User Manual SP2-4K 4K HDMI Splitter 1x2 All Rights Reserved Version: SP2-4K_2016V1.0 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device.
More informationTwo Channel 48 Volt Phantom Power Supply. Artcessories. User's Manual
Two Channel 48 Volt Phantom Power Supply Artcessories User's Manual IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage
More information7 Digital Photo Frame
7 Digital Photo Frame Instruction manual L7DPF17 12 month manufacturer's warranty -------------------------------------------------------------------------- --------------------------------------------------------------------------
More informationPOL-001 Fiber-Optic In-Line Polarizer. Operation Manual
POL-001 Fiber-Optic In-Line Polarizer Operation Manual Feb. 18, 2002 General Photonics Corp. Ph: (909) 590-5473 5228 Edison Ave. Fax: (909) 902-5536 Chino, CA 91710 USA www.generalphotonics.com Document
More informationDear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.
Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it. Contents 1. Features and Functions 2. User Safety 3. Nomenclature 4. Operation
More informationRev. F January 13, 1999 Part Number: OFL Operations Manual for the OFL 100 Mini-OTDR
Rev. F January 13, 1999 Part Number: OFL1-00-1000 Operations Manual for the OFL 100 Mini-OTDR Contents Page 1.0 General Information... 1 1.1 Unpacking and Inspection... 1 1.2 Precautions... 1 1.3 Recommended
More informationThanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference.
CONTENTS Thanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference. 01Read This First...01 Product Information...01 Standard Package Contents...02
More informationDTW 400/DTW Digital Torque Tester/Screwdriver User s Guide
DTW 400/DTW 405 - Digital Torque Tester/Screwdriver User s Guide LIST OF EQUIPMENT 1. Digital Torque Tester/Screwdriver (DTW 400 with CW and CCW ratchet (1/4 female hex) 2. 2 Phillips tips (DTW 405 with
More informationPORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL. Handheld Microphone Headset Transmitter
PORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL X1 Headset Microphone AWX6042H VHF Wireless Headset Transmitter Handheld Microphone Headset Transmitter Thank you
More informationENVIRONMENTAL PROTECTION
ENVIRONMENTAL PROTECTION Do not dispose of this product with the normal household waste at the end of its life cycle. Return it to a collection point for the recycling of electrical and electronic devices.
More informationSLA Battery Capacity Analyzer
Model: 601B SLA Battery Capacity Analyzer USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation,
More informationInstallation and Operation Back-UPS BR1000G-IN / BR1500G-IN
Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service
More informationVIS Video Inspection Scope
User s Guide VIS 300 - Video Inspection Scope VIS1-00-2000, Rev A, 6-09-10 Specifications subject to change without notice Contents Section 1 - General Overview A. Contact ODM for customer service B. Unpacking
More informationEOS-6000 Series Optical A/B Switch User Manual DC Version
EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2
More informationEQUIPMENT Operation Manual
EQUIPMENT Operation Manual 7700 Label # 988830 Loctite Handheld LED Light Sources Part Number 1427231 Model 7700 Light Source II Part Number 98595 Model 7703 Light Source TABLE OF CONTENTS 1. PLEASE OBSERVE
More informationDigital Torque Wrenches
2 YEAR WARRANTY (RESTRICTIONS APPLY) Imada, Inc. warrants its products to the original purchaser to be free from defects in workmanship and material under normal use and proper maintenance for two years
More informationTABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...
TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...
More information