MC Lot A MW

Size: px
Start display at page:

Download "MC Lot A MW"

Transcription

1

2 MC-2302 N 6 -Benzyladenine, [benzyl ring- 14 C]- Lot A MW A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration was 0.5 mg/ml. N 6 -Benzyladenine, [benzyl ring- 14 C]- concentration was 52.0 µci/ml. Volume of standard alone injection was 1.0 µl Volume of N 6 -Benzyladenine, [benzyl ring- 14 C]- alone injection was 1.0 µl. Co-injection solution consisted of 1.0 µl N 6 -Benzyladenine, [benzyl ring- 14 C] µl standard. Volume of co-injection was 2.0 µl. Volume of blank injection was 1.0 µl. B) Mass spectrometry - Positive mode C) NMR

3 2/18/ :06 AM Chromatogram L:\int42300.PRM Page 1 of 2 Chromatogram Info: MC-2302 N6-Benzyladenine, [benzyl ring-14c]- Lot A M W File Name : L:\int42300 File Created : 2/18/ :55:30 AM Origin : Acquired, Acquisition started 3/11/2010 4:14:45 PM Acquired Date : 3/11/2010 4:54:44 PM Project : Test By : Administrator Method : Unit4-40minrun By : Administrator Description : Radiochemical trace of 14C material alone Created : 6/12/ :30 AM Modified : 2/18/ :06 AM Column : Detection : Radiochemical Mobile Phase : Temperature : Flow Rate : Pressure : Note : L:\ int Unit 4 Radio Voltage Time [min.]

4 2/18/ :06 AM Chromatogram L:\int42300.PRM Page 2 of 2 Compound Name Reten. Time [min] [mv.s] Result Table (Uncal - L:\int Unit 4 Radio) Efficiency [th.pl] Eff/l [t.p./m] Symmetry/Taili ng Response Factor Resolution Total

5 2/18/ :05 AM Chromatogram L:\int42300.PRM Page 1 of 2 Chromatogram Info: MC-2302 N6-Benzyladenine, [benzyl ring-14c]- Lot A M W File Name : L:\int42300 File Created : 2/18/ :55:30 AM Origin : Acquired, Acquisition started 3/11/2010 4:14:45 PM Acquired Date : 3/11/2010 4:54:44 PM Project : Test By : Administrator Method : Unit4-40minrun By : Administrator Description : UV trace of 14C material alone Created : 6/12/ :30 AM Modified : 2/18/ :59 AM Column : Detection : UV 254nm Mobile Phase : Temperature : Flow Rate : Pressure : Note : L:\ int Unit 4 UV Voltage Time [min.]

6 2/18/ :05 AM Chromatogram L:\int42300.PRM Page 2 of 2 Compound Name Reten. Time [min] [mv.s] Result Table (Uncal - L:\int Unit 4 UV) Efficiency [th.pl] Eff/l [t.p./m] Symmetry/Taili ng Total Response Factor Resolution

7 2/18/ :07 AM Chromatogram L:\int42301.PRM Page 1 of 2 Chromatogram Info: MC-2302 N6-Benzyladenine, [benzyl ring-14c]- Lot A M W File Name : L:\int42301 File Created : 2/18/ :55:29 AM Origin : Acquired, Acquisition started 3/12/ :52:49 AM Acquired Date : 3/12/ :32:48 AM Project : Test By : Administrator Method : Unit4-40minrun By : Administrator Description : UV trace of standard alone Created : 6/12/ :30 AM Modified : 2/18/ :00 AM Column : Detection : UV 254nm Mobile Phase : Temperature : Flow Rate : Pressure : Note : L:\ int Unit 4 UV 300 Voltage Time [min.]

8 2/18/ :07 AM Chromatogram L:\int42301.PRM Page 2 of 2 Compound Name Reten. Time [min] [mv.s] Result Table (Uncal - L:\int Unit 4 UV) Efficiency [th.pl] Eff/l [t.p./m] Symmetry/Taili ng Response Factor Resolution Total

9 2/18/ :09 AM Chromatogram L:\int42302.PRM Page 1 of 2 Chromatogram Info: MC-2302 N6-Benzyladenine, [benzyl ring-14c]- Lot A M W File Name : L:\int42302 File Created : 2/18/ :55:29 AM Origin : Acquired, Acquisition started 3/12/ :11:49 PM Acquired Date : 3/12/ :51:48 PM Project : Test By : Administrator Method : Unit4-40minrun By : Administrator Description : Radiochemical trace of 14C material co-injected with standard Created : 6/12/ :30 AM Modified : 2/18/ :08 AM Column : Detection : Radiochemical Mobile Phase : Temperature : Flow Rate : Pressure : Note : 500 L:\ int Unit 4 Radio Voltage Time [min.]

10 2/18/ :09 AM Chromatogram L:\int42302.PRM Page 2 of 2 Compound Name Reten. Time [min] [mv.s] Result Table (Uncal - L:\int Unit 4 Radio) Efficiency [th.pl] Eff/l [t.p./m] Symmetry/Taili ng Response Factor Resolution Total

11 2/18/ :08 AM Chromatogram L:\int42302.PRM Page 1 of 2 Chromatogram Info: MC-2302 N6-Benzyladenine, [benzyl ring-14c]- Lot A M W File Name : L:\int42302 File Created : 2/18/ :55:29 AM Origin : Acquired, Acquisition started 3/12/ :11:49 PM Acquired Date : 3/12/ :51:48 PM Project : Test By : Administrator Method : Unit4-40minrun By : Administrator Description : UV trace of 14C material co-injected with standard Created : 6/12/ :30 AM Modified : 2/18/ :07 AM Column : Detection : UV 254nm Mobile Phase : Temperature : Flow Rate : Pressure : Note : 600 L:\ int Unit 4 UV Voltage Time [min.]

12 2/18/ :08 AM Chromatogram L:\int42302.PRM Page 2 of 2 Compound Name Reten. Time [min] [mv.s] Result Table (Uncal - L:\int Unit 4 UV) Efficiency [th.pl] Eff/l [t.p./m] Symmetry/Taili ng Response Factor Resolution Total

13 2/18/ :09 AM Chromatogram L:\int42299.PRM Page 1 of 2 Chromatogram Info: MC-2302 N6-Benzyladenine, [benzyl ring-14c]- Lot A M W File Name : L:\int42299 File Created : 2/18/ :55:29 AM Origin : Acquired, Acquisition started 3/11/2010 3:09:59 PM Acquired Date : 3/11/2010 3:49:58 PM Project : Test By : Administrator Method : Unit4-40minrun By : Administrator Description : UV trace of blank injection Created : 6/12/ :30 AM Modified : 2/18/ :59 AM Column : Detection : UV 254nm Mobile Phase : Temperature : Flow Rate : Pressure : Note : 8 L:\ int Unit 4 UV 6 4 Voltage Time [min.]

14 2/18/ :09 AM Chromatogram L:\int42299.PRM Page 2 of 2 Result Table (Uncal - L:\int Unit 4 UV) Compound Name Reten. Time [min] [mv.s] No peak to report Efficiency [th.pl] Eff/l [t.p./m] Symmetry/Taili ng Response Factor Resolution

15 C:\Xcalibur\data\MC MW 3/8/2010 4:31:41 PM MC MW RT: Relative Abundance Time (min) NL: 2.56E8 TIC F: MS MC MW MC MW #1-199 RT: AV: 199 NL: 8.00E7 T: + c Q3MS [ ] MC MW#1-199 RT: AV: T: + c Q3MS [ ] m/z= m/z Intensity Relative Relative Abundance m/z

16 NAME MC MW EXPNO 1 PROCNO 1 Date_ Time INSTRUM spect PROBHD 5 mm PABBO BB PULPROG zg30 TD SOLVENT MeOD NS 1000 DS 2 SWH Hz FIDRES Hz AQ sec RG 4 DW usec DE 6.50 usec TE K D sec TD0 1 ======== CHANNEL f1 ======== NUC1 1H P usec PL db PL1W W SFO MHz SI SF MHz WDW no SSB 0 LB 0.00 Hz GB 0 PC 1.00 MC2302 1H NMR in MeOD Batch MW ppm

MT Thymidine, [methyl- 3 H]- Lot A THN

MT Thymidine, [methyl- 3 H]- Lot A THN MT-6036 Thymidine, [methyl- 3 H]- Lot 846-160-065-A-20110826-THN A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration

More information

MC Prochloraz, [phenyl- 14 C]- Lot A JH

MC Prochloraz, [phenyl- 14 C]- Lot A JH Prochloraz, [phenyl- 14 C]- Lot 48-12-492-A-29131-JH A) All chromatograms were run using the HPLC method described on the Product Data Sheet. Concentrations and volumes: Standard solution concentration

More information

NUSRAT HUSSAIN/DR.IQBAL/NH-ST-1 1H

NUSRAT HUSSAIN/DR.IQBAL/NH-ST-1 1H Electronic Supplementary Material (ESI) for RSC Advances. This journal is The Royal Society of Chemistry 2018 1.21 1.48 1.47 0.88 0.88 1.39 1.69 2.66 1.45 1.54 1.66 1.51 1.31 1.482 1.538 1.543 1.549 1.577

More information

ΔM15 ΔlacX74 reca1 enda1 arad139 Δ(ara,

ΔM15 ΔlacX74 reca1 enda1 arad139 Δ(ara, Nucleotidylation of Unsaturated Carbasugar in Validamycin Biosynthesis Jongtae Yang, 1 Hui Xu, 1,2 Yirong Zhang, 2 Linquan Bai, 2 Zixin Deng, 2 Taifo Mahmud 1, * 1 Department of Pharmaceutical Sciences,

More information

FOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9

FOCUS. Image Based Automatic Shimming Using B 0 Gradients. Installation and Users Guide Version 0.9 FOCUS Image Based Automatic Shimming Using B 0 Gradients Installation and Users Guide Version 0.9 FOCUS - Field Optimization by Computed Update of Shims Joost A. B. Lohman, Bruker Spectrospin ltd, U.K.

More information

TOCSY 15. Goto. Introduction Pulse Sequence Diagram AVANCE User s Guide Bruker 167

TOCSY 15. Goto. Introduction Pulse Sequence Diagram AVANCE User s Guide Bruker 167 Chapter TOCSY 15 Introduction 15.1 Goto TOtal Correlation SpectroscopY provides a different mechanism of coherence transfer than COSY for 2D correlation spectroscopy in liquids. In TOCSY, cross peaks are

More information

Agilent GC/MSD Instructions

Agilent GC/MSD Instructions Agilent GC/MSD Instructions GC/MS SAMPLE PREPARATION: Sample Components to Avoid Completely: The following should never be injected: metals, strong acids or bases, salts, oligomeric and polymeric material.

More information

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Familiarization Guide Before you begin 3 Prepare your system 3 Prepare the samples required for data acquisition

More information

In-line purification of equilibrium mixtures. Melissa Graewert June 25 th

In-line purification of equilibrium mixtures. Melissa Graewert June 25 th In-line purification of equilibrium mixtures Melissa Graewert June 25 th The odd one out Polydisperse samples Aggregates intrinsic property of the sample eg. monomer-dimer-oligomer equilibrium or incomplete

More information

Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence

Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence Supporting Information for Supramolecular Approach to Enzyme Sensing on Paper Discs Using Lanthanide Photoluminescence Tumpa Gorai and Uday Maitra* Department of Organic Chemistry, Indian Institute of

More information

2 Dimensional NMR User s Brief Guide

2 Dimensional NMR User s Brief Guide 2D NMR Handout 7/17/18 Weiguo Hu 2 Dimensional NMR User s Brief Guide (This handout presumes your thorough familiarity with the 1D handout commands and their use!) Options There are a vast number of 2D

More information

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12 Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12 DOSY Diffusion Ordered SpectroscopY. NMR diffusion experiments, like DOSY, are used to determine the diffusion coefficients of solute

More information

Agilent 1260 Infinity Diode Array Detector

Agilent 1260 Infinity Diode Array Detector Agilent 126 Infinity Diode Array Detector Features, Technical Details, Specifications and Ordering Details 1 x higher sensitivity for HPLC and RRLC The Agilent 126 Infinity Diode Array Detector (DAD) features

More information

Automated Fraction Re-Analysis Does it really make sense?

Automated Fraction Re-Analysis Does it really make sense? Automated Fraction Re-Analysis Does it really make sense? Presented by: Udo Huber 1995 PHD in organic chemistry from the University Karlsruhe/Germany 1996-97 Postdoctoral fellow at the University of Hawai

More information

Introduction to the HPLC ChemStation and Acquisition

Introduction to the HPLC ChemStation and Acquisition Introduction to the HPLC ChemStation and Acquisition In This Section, We Will Discuss: How to work in the Microsoft Windows Environment The structure of the ChemStation Software. How to set up an acquisition

More information

OpenLynx User's Guide

OpenLynx User's Guide OpenLynx User s Guide OpenLynx User's Guide Version 4.0 Waters part No 715000405 Micromass Part No - 6666670 5 February, 2002 i OpenLynx User s Guide OpenLynx User s Guide The software described in this

More information

GEARMOTORS AF MOTORS FOR INVERTER C-1

GEARMOTORS AF MOTORS FOR INVERTER C-1 C-1 C-2 C-3 C-4 R R C-5 C-6 C-7 1.47 14.7 584Hz 438Hz 318Hz 270Hz 234Hz 206Hz 167Hz 140Hz 121Hz 100Hz 81.4Hz 68.6Hz 59.4Hz 49.2Hz 40.2Hz 33.7Hz 28.9Hz 24.5Hz 21.2Hz 17.9Hz 15.2Hz 12.8Hz 3.11 4.15 5.70

More information

Agilent RapidFire 300 High-throughput Mass Spectrometry System

Agilent RapidFire 300 High-throughput Mass Spectrometry System Agilent RapidFire 300 High-throughput Mass Spectrometry System Data Analysis Guide Installation 2 To install Agilent RapidFire Integrator software 2 Preparing Data Collected in Plates Mode for RapidFire

More information

TraceFinder Analysis Quick Reference Guide

TraceFinder Analysis Quick Reference Guide TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in the Thermo TraceFinder 3.0 analytical software. For detailed descriptions

More information

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph Agilent 1100 ; VWD, DAD, FLD and RID Scientific Equipment Center, Prince Of Songkla University Operating Manual High Performance Liquid Chromatograph

More information

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser. The UltiMate Solvent Organizer 3.9 Specifications 3.9.1 Solvent Organizer Reservoirs Solvent Degassing Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter.

More information

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751) Dissimilar This manual is intended to be only a very brief introduction for using the Bruker 400 MHz NMR spectrometer (PS751) at the California State University LA NMR Facility. For complete information

More information

Introduction to Time-of-Flight Mass

Introduction to Time-of-Flight Mass Introduction to Time-of-Flight Mass Spectrometry and Deconvolution Nicholas Hall Speaker Mark Libardoni, Pete Stevens, Joe Binkley Life Science & Chemical Analysis Centre St. Joseph, Michigan, USA e-seminar

More information

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide

Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide What is the MassHunter Personal Pesticide Database Kit? 1 Kit Content 2 Where to find more information 3 Before You Begin 4

More information

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

3 Starting the chiral HPLC and logging into LC Real Time Analysis. Edition: 1.2 Date: 7-Oct-11 Page 1 of 5 1 Responsibilities. First person responsible: Mariëlle Delville. Second person responsible: Helene I.V. Amatdjais-Groenen. 2 Definitions. Read the information on

More information

KJM Proton T1 Spectra on the AVI-600 and AVII-600. Version 1.0

KJM Proton T1 Spectra on the AVI-600 and AVII-600. Version 1.0 KJM 9250 Proton T1 Spectra on the AVI-600 and AVII-600 Version 1.0 Professor Emeritus Alistair Lawrence Wilkins, University of Waikato, New Zealand. February 2018 Proton T1 Spectra on the AVI-600 and AVII-600

More information

Thermo Xcalibur Getting Started (Quantitative Analysis)

Thermo Xcalibur Getting Started (Quantitative Analysis) Thermo Xcalibur Getting Started (Quantitative Analysis) XCALI-97207 Revision B September 2010 2010 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur, Surveyor, and Accela are registered trademarks

More information

Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize.

Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize. Standard Operating Procedure Remcho Research Group P a g e 1 Agilent 1100 HPLC ChemStation 1) Turn on all the modules for HPLC system (CapPump G1376A, DAD G1315B) and allow for system to initialize. 2)

More information

Steps for LCMS-8040 Triple Quadrupole

Steps for LCMS-8040 Triple Quadrupole Steps for LCMS-8040 Triple Quadrupole June 2017 Version 2 A. Data Acquisition 1. Check lights on MS. There should be a total of three lights lit by LED. One of them is blinking. Power Blinking Gas Status

More information

NMR Training VNMRJ 4.2A/VNMRS 400

NMR Training VNMRJ 4.2A/VNMRS 400 NMR Training VNMRJ 4.2A/VNMRS 400 The VNMRS/new 400 MHz NMR uses VNMRJ 4.2A. Although VNMRJ is different than VNMRalmost ALL typed commands that you know from VNMR should work. LOGIN: Your username is

More information

1D and 2D Experiments Step-by-Step Tutorial

1D and 2D Experiments Step-by-Step Tutorial 1D and 2D Experiments Step-by-Step Tutorial Basic Experiments User Guide Version 004 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken

More information

Cat. # Lot #'s A & A058670

Cat. # Lot #'s A & A058670 Analytical Reference Materials Retention Time Marker Standard Cat. # 31637 Lot #'s A5895 & A5867 11 Benner Circle Bellefonte, PA 1683-881 (81) 353-13 FOR LABORATORY USE ONLY. READ MSDS PRIOR TO USE. MANUFACTURED

More information

MNova Version Installation Instructions.

MNova Version Installation Instructions. MNova Version 12.0.0 Installation Instructions. Note: This Document contains information for a new NMR user. Carefully read and accomplish each section before moving to the next. If you can t finish a

More information

Quick Guide to the Star Bar

Quick Guide to the Star Bar Saturn View Saturn Writer Quick Guide to the Star Bar Last active Chromatogram in SaturnView Last active method in the Method Editor Click with the right mouse button on the Star Bar to get this menu Sample,

More information

Technical Overview. Introduction

Technical Overview. Introduction Performance characteristics of the Agilent 12 Infinity Series Variable Wavelength Detectors Faster results, improved sensitivity and absolute data security Technical Overview Introduction The Agilent 12

More information

Xcalibur Library Browser

Xcalibur Library Browser Thermo Xcalibur Library Browser User Guide Creating and Searching Spectral Libraries Software Version 3.0 XCALI-97552 Revision A June 2013 2013 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur

More information

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods? Retention Time Locking with the MSD Productivity ChemStation Technical Overview Introduction A retention time is the fundamental qualitative measurement of chromatography. Most peak identification is performed

More information

Title. Author(s)Kato, Eisuke; Uenishi, Yuta; Inagaki, Yosuke; Kuroka. CitationBioscience biotechnology and biochemistry, 80(11): 2. Issue Date

Title. Author(s)Kato, Eisuke; Uenishi, Yuta; Inagaki, Yosuke; Kuroka. CitationBioscience biotechnology and biochemistry, 80(11): 2. Issue Date Title Isolation of rugosin A, B and related compounds as d Author(s)Kato, Eisuke; Uenishi, Yuta; Inagaki, Yosuke; Kuroka CitationBioscience biotechnology and biochemistry, 80(11): 2 Issue Date 2016-08

More information

Statistical Process Control in Proteomics SProCoP

Statistical Process Control in Proteomics SProCoP Statistical Process Control in Proteomics SProCoP This tutorial will guide you through the installation of SProCoP and using it to perform statistical analysis on a sample Skyline file. Getting Started

More information

SIMAT: GC-SIM-MS Analayis Tool

SIMAT: GC-SIM-MS Analayis Tool SIMAT: GC-SIM-MS Analayis Tool Mo R. Nezami Ranjbar September 10, 2018 1 Selected Ion Monitoring Gas chromatography coupled with mass spectrometry (GC-MS) is one of the promising technologies for qualitative

More information

Performing Internal Standard Calibration using PeakSimple version 3.51

Performing Internal Standard Calibration using PeakSimple version 3.51 For this example, we will create a 5 point calibration curve for Glycerin using Butanetriol as the Internal Standard. Load the level 1 chromatogram into channel 1. ( File/Open ) Identify the Butanetriol

More information

15. HOMONUCLEAR COSY

15. HOMONUCLEAR COSY Homonuclear COSY Page 67 15. HOMONUCLEAR COSY by cg fry: created 12/27/94 updated 11/26/00 In COrrelational SpectroscopY (COSY), a fast 2D spectrum is usually obtained first. This initial set of data takes

More information

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400 1 DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400 400: The Bruker DPX 400 has a broadband probe with 1 H Channel and X-Channel tunable from (30-300 MHz). Both Channels may be tuned researchers.

More information

NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES. 08/8/2005 rajan paranji

NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES. 08/8/2005 rajan paranji NMR FACILITY DEPARTMENT OF CHEMISTRY University of Washington XWINNMR 3.5 TRAINING NOTES 08/8/2005 rajan paranji CONTENTS Views of XWINNMR INTERFACE 4 Operating the Bruker Spectrometer FLOW CHART 5 LOGON

More information

TopSpin is the successor to a program called XWinNMR, which appeared in the mid- 90s (I believe) and was used to run Bruker spectrometers until it

TopSpin is the successor to a program called XWinNMR, which appeared in the mid- 90s (I believe) and was used to run Bruker spectrometers until it 1 2 TopSpin is the successor to a program called XWinNMR, which appeared in the mid- 90s (I believe) and was used to run Bruker spectrometers until it was replaced by TopSpin in 2005 or so. While much

More information

Quadri-channel receiver RD10 (v.1.01_101215)

Quadri-channel receiver RD10 (v.1.01_101215) (v.1.01_101215) User manual TRIKDIS, JSC Draugystes St. 17, LT-51229 Kaunas, Lithuania Phone: +370 37 408040 Fax: + 370 37 760554 E-mail.: info@trikdis.lt Web: www.trikdis.lt Table of Contents 1 Introduction...

More information

Inolux Surface Mount High Power Ultraviolet LED IN-3531SCUV

Inolux Surface Mount High Power Ultraviolet LED IN-3531SCUV Inolux Surface Mount High Power Ultraviolet LED Official Product Product: Data Sheet No. Tentative Product **************** Sept. 5, 2016 Version of 1.3 Page 1/13 DISCLAIMER... 3 LABEL SPECIFICATIONS...

More information

Agilent G6855AA MassHunter Personal

Agilent G6855AA MassHunter Personal Agilent G6855AA MassHunter Personal Forensic Toxicology Database Kit Quick Start Guide What is the MassHunter Personal Forensic Toxicology Database Kit? 1 Kit Content 2 Where to find more information 4

More information

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin. TopSpin QuickStart Preliminaries Sign Up Sign up for instrument time at calendar.yahoo.com/hmcnmr The password is nmr. During the summer, 1100-1200 and 1600-1700 are reserved for walk-on use (15 min maximum

More information

Agilent Splitter Kits

Agilent Splitter Kits Agilent Splitter Kits Installation and Configuration This technical note describes the installation and configuration of the Agilent Splitter Kits in an Agilent 1260 Infinity Series System or an Agilent

More information

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation Automated Submission for Analysis Processing (ASAP) Operator s Guide 2002 Dionex Corporation Document No. 031843 Revision 01 May 2002 2002 by Dionex Corporation All rights reserved worldwide. Printed in

More information

Q Exactive HF-X QuickStart Guide

Q Exactive HF-X QuickStart Guide Q Exactive HF-X QuickStart Guide About this Guide Q Exactive HF-X Tune This Q Exactive HF-X QuickStart Guide gives an introduction on setting up and using the Thermo Scientific Q Exactive HF-X mass spectrometer.

More information

Unprecedented In Water Imidazole- Carbonylation: Paradigm shift for Preparation of Urea and Carbamate

Unprecedented In Water Imidazole- Carbonylation: Paradigm shift for Preparation of Urea and Carbamate Unprecedented In Water Imidazole- Carbonylation: Paradigm shift for Preparation of Urea and Carbamate Kamlesh J. Padiya* Sandip Gavade, Bhavana Kardile, Manojkumar Tiwari, Swapnil Bajare, Madhav Mane,

More information

Getting Started. Environmental Analysis Software

Getting Started. Environmental Analysis Software Getting Started Environmental Analysis Software Environmental Software Overview The Environmental software is a data acquisition and data analysis package designed to assist you in complying with United

More information

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy PINMRF Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy INCLUDING: AV-III-400-HD w/ 5mm BBFO SmartProbe 369 WTHR AV-III-500-HD w/ 5mm BBFO

More information

SCP for Plastics Processing

SCP for Plastics Processing Measure & Analyze MCS SCP for Plastics Processing Modules for Signal Conditioning System Type 2853A..., 2207A..., 5063A..., 5227A..., 5613A... The SCP is a modular system for conditioning measuring signals

More information

PD2CAEPIPE - Plant Design-to-CAEPIPE Translator

PD2CAEPIPE - Plant Design-to-CAEPIPE Translator PD2CAEPIPE - Plant Design-to-CAEPIPE Translator (for converting PCF files) 1.0 Installing Program To install PD2CAEPIPE on Windows NT, load the product CD supplied by InfoPlant and run the program "SETUP.EXE"

More information

Estimating the signal-to-noise ratio of the spin-noise signal in the glucose solution. where the following factors are taken into account:

Estimating the signal-to-noise ratio of the spin-noise signal in the glucose solution. where the following factors are taken into account: SNR SN = SNR eb r N r µ r LW r SW, Estimating the signal-to-noise ratio of the spin-noise signal in the glucose solution The SNR of the spin- noise signal (SNR SN) can be estimated via the SNR of the ethylbenzene

More information

Aqueous GPC Instructions - Detailed

Aqueous GPC Instructions - Detailed Aqueous GPC Instructions - Detailed Waste Bottle Columns PL Datastream Injection Port GPC Computer UV Detector GPC Pump Eluent Bottle The Aqueous GPC Set Up RI Detector Important The points below must

More information

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP) 500 MHz Solution-state NMR Procedure (Bruker AVANCE Machines running TopSpin under WINDOWS XP) Jerry Hu, x7914, jghu@mrl.ucsb.edu Shamon Walker, x6079 shamonwalker@mrl.ucsb.edu Materials Research Laboratory

More information

North Carolina State University Department of Chemistry Varian NMR Training Manual

North Carolina State University Department of Chemistry Varian NMR Training Manual North Carolina State University Department of Chemistry Varian NMR Training Manual by J.B. Clark IV & Dr. S. Sankar 1 st Edition 05/15/2009 Section 1: Essential Operations for Basic 1D Spectra Preparing

More information

Agilent VnmrJ 3.2. Quick Start Guide

Agilent VnmrJ 3.2. Quick Start Guide Agilent VnmrJ 3.2 Quick Start Guide VnmrJ 3.2 Interface 3 Overview 4 Prepare Sample 5 Load Sample 6 Enter Sample Information 7 Build Study Queue 8 Run Study Queue 8 Process Data 9 Plot Data 10 This Quick

More information

Real-time Data Compression for Mass Spectrometry Jose de Corral 2015 GPU Technology Conference

Real-time Data Compression for Mass Spectrometry Jose de Corral 2015 GPU Technology Conference Real-time Data Compression for Mass Spectrometry Jose de Corral 2015 GPU Technology Conference 2015 Waters Corporation 1 Introduction to LC/IMS/MS LC/IMS/MS is the combination of three analytical techniques

More information

70 SERIES. Line monitoring relay

70 SERIES. Line monitoring relay 70 SRIS 70 SRIS lectronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window Mode, Phase

More information

C190-E092A Prominence Gel Permeation Chromatography System Shimadzu High Performance Liquid Chromatograph

C190-E092A Prominence Gel Permeation Chromatography System Shimadzu High Performance Liquid Chromatograph C90-E092A Prominence Gel Per meation Chromatography System Shimadzu High Per for mance Liquid Chromatograph Prom i n e n c e G e l Pe r m e a t i o n Chromatography System Gel permeation chromatography

More information

New Features of Deconvolution Reporting Software Revision A.02 Technical Note

New Features of Deconvolution Reporting Software Revision A.02 Technical Note New Features of Deconvolution Reporting Software Revision A.2 Technical Note Authors Mike Szelewski Chin-Kai Meng Agilent Technologies, Inc. 28 Centerville Road Wilmington, DE 1988-161 USA Abstract Deconvolution

More information

Sepacore X10 / X50 system Technical data sheet

Sepacore X10 / X50 system Technical data sheet Sepacore X10 / X50 system Technical data sheet Sepacore X10 and X50 flash chromatography systems address most requirements for the purification of organic compounds. Whether a crude synthesis mixture or

More information

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION MESR321 Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway Three-way Isolation Ethernet-Enable Modbus RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves

More information

NANO SPECTROPHOTOMETER

NANO SPECTROPHOTOMETER PRODUCT CATALOG NANO SPECTROPHOTOMETER www.biolabscientific.com NANO SPECTROPHOTOMETER Biolab Nano spectrophotometer is a compact, micro volume UV Visible Spectrophotometer with enhanced sensitivity that

More information

PeakSimple Calibration Tutorial August 2008

PeakSimple Calibration Tutorial August 2008 Launch PeakSimple software. You do not need the A/D hardware connected, but it is OK if it is. Load an example chromatogram from the PeakSimple folder. If you have installed PeakSimple version 3.65, then

More information

Intro to 2D NMR: Homonuclear correlation COSY, lr-cosy, and DQ-COSY experiments

Intro to 2D NMR: Homonuclear correlation COSY, lr-cosy, and DQ-COSY experiments Homework 9 Chem 636, Spring 2014 due at the beginning of lab April 8-10 updated 8 Apr 2014 (cgf) Intro to 2D NMR: Homonuclear correlation COS, lr-cos, and DQ-COS experiments Use Artemis (Av-400) or Callisto

More information

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Getting low-resolution GC-MS data on the JEOL GCMate Introduction Getting low-resolution GC-MS data on the JEOL GCMate Introduction GC-MS is a technique that combines gas phase separation and mass-based detection/characterization of analytes. It s a very sensitive method

More information

Content. Getting data organized Good data processing Plotting

Content. Getting data organized Good data processing Plotting 1 Content Getting data organized Good data processing Plotting 2 Documentation: Software Manuals available in TopSpin Software manuals are accessible from within TopSpin under the icon. A good place to

More information

Soprane II Documentation

Soprane II Documentation Soprane II Documentation p. 1 / 198 Table of contents 1. INTRODUCTION 6 2. INSTALLATION 6 3. ANALYZER CONFIGURATION 8 3.1. Creation 9 3.1.1. Analyzer creation with network connection 11 3.1.2. Analyzer

More information

Pulse Programming. Reference for TopSpin 2.0 Version 2.0.0

Pulse Programming. Reference for TopSpin 2.0 Version 2.0.0 Pulse Programming Reference for TopSpin 2.0 Version 2.0.0 Copyright (C) 2006 by Bruker BioSpin GmbH All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

More information

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR 1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR Spectrometer without the Sample Changer and IconNMR Scheduling NMR Time: Any use of the 700 MHz NMR spectrometer requires prior

More information

TraceFinder Administrator Quick Reference Guide

TraceFinder Administrator Quick Reference Guide TraceFinder Administrator Quick Reference Guide This quick reference guide discusses the application configuration tasks assigned to the ITAdmin and LabDirector roles when user security is activated in

More information

HiQ sil TM HPLC Columns

HiQ sil TM HPLC Columns www.kromatek.co.uk KYA Technologies of Japan KYA Technologies Corporation, Tokyo, Japan established in 1998 to develop a range of HPLC products. The latest product HiQ sil HS is a high performance silica

More information

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD

Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD Agilent Max-Light Cartridge Cell Information for G4212A/B DAD and G7117A/B DAD Information about the Max-Light Cartridge Cells 2 Specifications 2 Description of the dispersion volume V(σ) 2 Recommendations

More information

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable 70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring

More information

Optimizing System Dispersion on the Agilent 1290 Infinity II LC

Optimizing System Dispersion on the Agilent 1290 Infinity II LC Optimizing System Dispersion on the Agilent 1290 Infinity II LC The Agilent Ultralow Dispersion Kit Technical Overview Authors Bettina Schuhn and Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

More information

Vanderbilt Small Molecule NMR Center

Vanderbilt Small Molecule NMR Center Vanderbilt Small Molecule NMR Center Instructions for Using TOPSPIN version 2.0 DRX 400: Setting up 1H, 13C (1H decoupled), and 31P NMR Experiments Getting started: Sample Preparation: Make sure your sample

More information

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP)

500 MHz Solution-state NMR Procedure. (Bruker AVANCE Machines running TopSpin under WINDOWS XP) 500 MHz Solution-state NMR Procedure (Bruker AVANCE Machines running TopSpin under WINDOWS XP) Jerry Hu, x7914, jghu@mrl.ucsb.edu Shamon Walker, x3248 shamonwalker@mrl.ucsb.edu Materials Research Laboratory

More information

General Information for Automated Inova 500 MHz NMR (Indy)

General Information for Automated Inova 500 MHz NMR (Indy) General Information for Automated Inova 500 MHz NMR (Indy) Primary Contacts: NMR Facility Manager: David VanderVelde, x3004, davidv@caltech.edu GLA: Pamela Tadross, x6131, 646-220-5789 (cell), 204 Church,

More information

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009 MSQ Plus Chromeleon / MSQ Plus Operator s Guide Document No. 065322 Revision 03 October 2009 Chromeleon / MSQ Plus Operator s Guide 2009 by Dionex Corporation All rights reserved worldwide. Printed in

More information

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution

Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution Agilent 1200 Infinity Series High Dynamic Range Diode Array Detector Solution User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2014 No part of this manual may be reproduced in any form

More information

Inolux Surface Mount High Power Ultraviolet LED IN-3531ACUV

Inolux Surface Mount High Power Ultraviolet LED IN-3531ACUV Inolux Surface Mount High Power Ultraviolet LED Official Product Product: Data Sheet No. Tentative Product **************** Aug. 21, 2015 Version of 1.1 Page 1/13 DISCLAIMER... 3 LABEL SPECIFICATIONS...

More information

New features and Workflow Enhancements Empower 3 Software

New features and Workflow Enhancements Empower 3 Software New features and Workflow Enhancements Empower 3 Software Mogens Hallas Nordic User Training 2011 Långvik, September 6th to 9th, 2011 2011 Waters Corporation 1 Empower 3 Architecture and operating systems

More information

GX5295 DIGITAL I/O DYNAMIC DIGITAL I/O WITH PER CHANNEL PROGRAMMABLE LOGIC LEVELS AND PMU PXI CARD DESCRIPTION FEATURES

GX5295 DIGITAL I/O DYNAMIC DIGITAL I/O WITH PER CHANNEL PROGRAMMABLE LOGIC LEVELS AND PMU PXI CARD DESCRIPTION FEATURES DYNAMIC WITH PER CHANNEL PROGRAMMABLE LOGIC LEVELS AND PMU PXI CARD 32 input / output channels, dynamically configurable on a per channel basis 4 control / timing channels with programmable levels 256

More information

MassHunter File Reader

MassHunter File Reader MassHunter File Reader vers 1.0.0 2015 Quadtech Associates, Inc. All Rights Reserved Release date: November 18, 2015 www.quadtechassociates.com MassHunter File Reader Welcome to MassHunter File Reader.

More information

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows wwwdataapexcom e-mail: clarity@dataapexcom DESCRIPTION DataApex Clarity 32bit multi instrument chromatography station for Windows Multi-detector instruments Easy to install and easy to use Graphical user

More information

TopSpin 3.5 Tips and Tricks. Nicole Kruse US Applications Pre PANIC Workshop February 20 th 2017

TopSpin 3.5 Tips and Tricks. Nicole Kruse US Applications Pre PANIC Workshop February 20 th 2017 TopSpin 3.5 Tips and Tricks Nicole Kruse US Applications Pre PANIC Workshop February 20 th 2017 Non-Uniform Sampling Incorporated into TopSpin 3.0 Higher Resolution NUS HSQC NS = 2 TD = 2048 NUS @ 10 %

More information

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2.

Quick Setup Instructions for the Knauer HPLC-System. Quick Setup Instructions for the Knauer HPLC-System For windows XP (using CHANCE vers. 2. For windows XP (using CHANCE vers. 2.0) Compiled by P. Madl Vers. 1.0 June 2011 1 / 9 1. Hardware Setup: Result 1.1. Attach RS 232 interface cable (designated as PC) to COM-port-1 of the laptop. 1.2. connect

More information

Quick Start. Model 203 Single Channel PeakSimple Data System. STEP 2 (optional) STEP 4 STEP 5 STEP 1. STEP 3 (optional)

Quick Start. Model 203 Single Channel PeakSimple Data System. STEP 2 (optional) STEP 4 STEP 5 STEP 1. STEP 3 (optional) The may be used with any brand or model of GC or HPLC offering an analog detector output signal ranging from 0-5V. It includes two independent, programmable controls (0-5V analog output) for temperature

More information

MassLynx 4.1 SCN 804. Release Notes. SQ Detector 2

MassLynx 4.1 SCN 804. Release Notes. SQ Detector 2 R E L E A S E N O T E S MassLynx 4.1 SCN 804 Release Notes SQ Detector 2 43464 Rev 01 Copyright Waters Corporation 2011. All rights reserved. Copyright 2011 Waters Corporation 43464_1. Waters is a registered

More information

Using SIMDIS Expert 9 (Separation Systems) with Clarity

Using SIMDIS Expert 9 (Separation Systems) with Clarity Using SIMDIS Expert 9 (Separation Systems) with Clarity The SIMDIS Expert 9 may be used with Clarity or Clarity Lite software to process the acquired chromatograms according to Simulated Distillation.

More information

UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X

UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X TABLE OF CONTENTS UC DAVIS NMR FACILITY BRUKER SHORT MANUAL FOR TOPSPIN 3.X VERSION 3 February, 2016 Disclaimer... 2 Conventions... 2 Routine 1D NMR Experiments Procedure for acquiring 1D Proton spectrum...

More information

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples

ANALYTICAL SYSTEMS. L3320 Autosampler with excellent accuracy and linearity. System configuration examples ANALYTICAL SYSTEMS Modular HPLC system can be configured according to customer needs from components as follows: PDA Detector with wavelength range 200-800 nm with scanning possibility or UV-VIS Detector

More information

TraceFinder Analysis Quick Reference Guide

TraceFinder Analysis Quick Reference Guide TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in Thermo TraceFinder analytical software. For detailed descriptions

More information

Tutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa

Tutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA 94598-1675/usa Saturn GC/MS Workstation Version 5.4 Tutorials Varian, Inc. 1999 03-914765-00:Rev. 1 1 Contents How to Exercises...1 Overview...1

More information