Use of OBX-11/OBR-25 in IHE LAB3 context. IHE-PaLM 13 Nov Filip Migom

Size: px
Start display at page:

Download "Use of OBX-11/OBR-25 in IHE LAB3 context. IHE-PaLM 13 Nov Filip Migom"

Transcription

1 Use of OBX-11/OBR-25 in IHE LAB3 context. IHE-PaLM 13 Nov Filip Migom

2 Order Results Management [LAB-3] Shall we apply S or O? 20/12/ CliniSys Group Commercial in Confidence 2

3 OBX-11 : Observation Result Status IHE : LAB-3: uses Reference HL7 V2.5.1 Refer to HL7 table Observation result status codes interpretation for valid values (source HL7 V2.7) A record may have an empty OBX-5? Shall we apply S or O 20/12/ CliniSys Group Commercial in Confidence 3

4 IHE Pathology & Laboratory Medicine Technical Framework, Vol. 2x (PaLM TF-2x): Transactions Shall we apply S or O C Result still final and verified!!! 20/12/ CliniSys Group Commercial in Confidence 4

5 Shall we replace a diagram with a table view Can we agree on this Table view? 20/12/ CliniSys Group Commercial in Confidence 5

6 OBX-11 OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM CASE : A correction is required To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL? FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] 20/12/ CliniSys Group Commercial in Confidence 6

7 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL? FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL? FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL? FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL? FM A result is validated and verified as a final value for the report 20/12/ CliniSys Group Commercial in Confidence 7

8 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL P FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL F FM A result is validated and verified as a final value for the report I is not allowed after F 20/12/ CliniSys Group Commercial in Confidence 8

9 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL P FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL F FM A result is validated and verified as a final value for the report W Is not supported by IHE LAB-3 20/12/ CliniSys Group Commercial in Confidence 9

10 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL P FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is validated and verified as a final value for the report W Is not supported by IHE LAB-3 20/12/ CliniSys Group Commercial in Confidence 10

11 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is validated and verified as a final value for the report W Is not supported by IHE LAB-3 C? The result is not Final. What is best? 20/12/ CliniSys Group Commercial in Confidence 11

12 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is validated and verified as a final value for the report W Is not supported by IHE LAB-3 C? The result is not Final. What is best? 20/12/ CliniSys Group Commercial in Confidence 12

13 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL W FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL W FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is validated and verified as a final value for the report W Is not supported by IHE LAB-3 20/12/ CliniSys Group Commercial in Confidence 13

14 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL C FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL C FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is validated and verified as a final value for the report C? Shall we allow C when no result is available C? The result is not Final. What is best? 20/12/ CliniSys Group Commercial in Confidence 14

15 OBX-11 : Observation Result Status OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL D FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. What status should we report in? [W] or [I] or [C] or [D] OBX 8 NM 82310^CALCIUM^GH 8 MG/DL D FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL D FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL C FM A result is validated and verified as a final value for the report D Is supported by IHE LAB-3 D? The value should remain empty 20/12/ CliniSys Group Commercial in Confidence 15

16 Shall we replace a diagram with a table view Can we agree on this Table view? 20/12/ CliniSys Group Commercial in Confidence 16

17 Shall we replace a diagram with a table view Can we agree on this Table view? 20/12/ CliniSys Group Commercial in Confidence 17

18 What do we have to change in IHE-PaLM Technical Framework A NEW CP 20/12/ CliniSys Group Commercial in Confidence 18

19 CP : Agreed to the message OBX 8 NM 82310^CALCIUM^GH 8 MG/DL I FM OBX 8 NM 82310^CALCIUM^GH MG/DL P FM OBX 8 NM 82310^CALCIUM^GH MG/DL F FM To discuss a CORRECTION OBX 8 NM 82310^CALCIUM^GH 8 MG/DL C FM The result has been re-opened for examination. The result itself is initial. A new report can be triggered. OBX-11 = C OBX 8 NM 82310^CALCIUM^GH 8 MG/DL C FM A result is available but not yet confirmed OBX 8 NM 82310^CALCIUM^GH MG/DL <?> C FM A result is confirmed and available for the report, but it is not verified OBX 8 NM 82310^CALCIUM^GH MG/DL <?> C FM A result is validated and verified as a final value for the report OBR-25 = C ORC-5 = A OBX-5 = OBX-8 = clear the flag ORBX-11 = C OBR-25 = C ORC-5 = CM 20/12/ CliniSys Group Commercial in Confidence 19

20 CP Replace the meaning of C Old : New (as in HL7 2.7 definition): Check if OBX-5 can be when OBX-11 = C? Change the diagram to use Status O for the first message Replace S with O 20/12/ CliniSys Group Commercial in Confidence 20

21 CP Change the diagram (make it more comprehensive) 20/12/ CliniSys Group Commercial in Confidence 21

22 CP??? ORC-5 correlated to OBR-25 OBX-11 Add a row A / C / C : for none final corrected results Correct (CM) into CM 20/12/ CliniSys Group Commercial in Confidence 22

CWLAB File Format Version 1.3

CWLAB File Format Version 1.3 Jeff Murray s Programming Shop, Inc. CWLAB File Format Version 1.3 Overview Although CAREWare already imports laboratory data through specific HL7 specifications controlled by major US laboratories, these

More information

Search the EHR-S FM. Search the EHR-S FM in EA, called Search in Model, can be done as follows:

Search the EHR-S FM. Search the EHR-S FM in EA, called Search in Model, can be done as follows: Search the EHR-S FM The EHR-S FM is a comprehensive standard, in particular the function list. If you are looking for certain functions it can be difficult to find them in the function list. EA can help

More information

HIMSS and RSNA. IHE Technical Framework Version 4.6. Errata

HIMSS and RSNA. IHE Technical Framework Version 4.6. Errata HIMSS and RSNA Integrating the Healthcare Enterprise IHE Technical Framework Version 4.6 Errata - 1 - Introduction The errata in this document are listed by section in the IHE Technical Framework. Each

More information

Page 1 w: e: T: (203)

Page 1 w:  e: T: (203) Quest Diagnostics - Lab Orders & Results interface development using nhapi Description: The purpose of this document is to define the scope of the project and the solution provided to the client. Requirements:

More information

MICROMD PM SETUP SPECIFICATIONS FOR SCHUYLER LAB IMPORT

MICROMD PM SETUP SPECIFICATIONS FOR SCHUYLER LAB IMPORT MICROMD PM SETUP SPECIFICATIONS FOR SCHUYLER LAB IMPORT This document contains information regarding data format for the above interface. If you need any in-depth information about any of the fields within

More information

THE HEALTH INFORMATION TECHNOLOGY SUMMIT

THE HEALTH INFORMATION TECHNOLOGY SUMMIT THE HEALTH INFORMATION TECHNOLOGY SUMMIT 2.05 Community-Based Collaborations: Developing Your Technical Strategy for Mobilizing Healthcare Data October 22 1:30 PM 60 minutes Wes, Hlamka and me Clinical

More information

Quest Diagnostics - Lab Orders & Results interface development using nhapi

Quest Diagnostics - Lab Orders & Results interface development using nhapi Quest Diagnostics - Lab Orders & Results interface development using nhapi Our client wanted to create a solution to interface its existing system with Quest Diagnostics. Basic integration requirement

More information

Mach7 Enterprise Imaging Platform v HL7 Conformance Statement

Mach7 Enterprise Imaging Platform v HL7 Conformance Statement Mach7 Enterprise Imaging Platform v11.7.2 2018 Manufacturer: Mach7 Technologies 480 Hercules Drive Colchester VT 05446 USA +1 802 861 7745 - phone +1 802 861 7779 - fax European Authorized Representative:

More information

IHE Radiology Technical Framework Supplement. Draft for Public Comment

IHE Radiology Technical Framework Supplement. Draft for Public Comment Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Imaging Clinical Decision Support Workflow (ICDSW) 15 Draft for Public Comment 20 Date: February 19, 2015 Author:

More information

Comparing a Standard (NAACCR Volume V) with a Draft Standard (HL7 version Implementation Guide: ELR Reporting to Public Health, Release 2)

Comparing a Standard (NAACCR Volume V) with a Draft Standard (HL7 version Implementation Guide: ELR Reporting to Public Health, Release 2) Comparing a Standard (NAACCR Volume V) with a Draft Standard (HL7 version 2.5.1 Implementation Guide: ELR Reporting to Public Health, Release 2) Jovanka Harrison, Ph.D., Lead for the NAACCR ELR Messaging

More information

KARL STORZ AIDA V1. HL7 Interface Description

KARL STORZ AIDA V1. HL7 Interface Description V1. HL7 Interface Description PRODUCT INFO OR1 OR1 111 1.0 01/2018/PI-E 1/12 2 Table of Contents Change History... 2 Table of Contents... 3 1 Introduction... 4 1.1 Purpose of the Document... 4 1.2 Abbreviations...

More information

ELINCS v1.1 to HL7R1 Change Summary

ELINCS v1.1 to HL7R1 Change Summary ELINCS v1.1 to HL7R1 Change Summary The California HealthCare Foundation (CHCF) has produced this document to provide Laboratory and EHR implementers of the ELINCS HL7-R1 implementation guide a means of

More information

KARL STORZ OR1 FUSION V1.4 HL7 Interface Description PRODUCT INFO OR1 OR /2018/PI-E 1/12

KARL STORZ OR1 FUSION V1.4 HL7 Interface Description PRODUCT INFO OR1 OR /2018/PI-E 1/12 HL7 Interface Description PRODUCT INFO OR1 OR1 105 1.1 02/2018/PI-E 1/12 Change History Version Date Changes Reason Editor BC-02 2017-03-09 Whole document Review findings TZ BC-01 2017-02-20 Whole document

More information

Introduction to HL7 Standards: v 2.x. W. Ed Hammond February 25, 2008

Introduction to HL7 Standards: v 2.x. W. Ed Hammond February 25, 2008 Introduction to HL7 Standards: v 2.x W. Ed Hammond February 25, 2008 Why use data interchange standards? Use of standards is becoming more universal. HL7 standards are likely to be in use already EHRVA

More information

HIE Participant Onboarding: Best Practices September 7, 2016

HIE Participant Onboarding: Best Practices September 7, 2016 HIE Participant Onboarding: Best Practices September 7, 2016 You have been automatically muted. Please use the Q&A panel to submit questions during the presentation Agenda Introductions Background Understanding

More information

IHE Radiology (RAD) Technical Framework. Volume 2 IHE RAD TF-2 Transactions

IHE Radiology (RAD) Technical Framework. Volume 2 IHE RAD TF-2 Transactions Integrating the Healthcare Enterprise 5 IHE Radiology (RAD) Technical Framework 10 Volume 2 IHE RAD TF-2 Transactions 15 20 Revision 16.0 Final Text August 4, 2017 25 Please verify you have the most recent

More information

Vianeta Communications OUTBOUND HL7 Interface Specifications

Vianeta Communications OUTBOUND HL7 Interface Specifications OUTBOUND HL7 Interface pecifications 1 Purpose The purpose of this document is to outline the Vianeta s requirements for OUTBOUND data with a standard HL7 interface. Message Type - ORU (Observational Report

More information

APSR 2.0 Public Comment

APSR 2.0 Public Comment APSR 2.0 Public Comment Remarks 1 Comments on IHE platform Vol. 1, section 10.3: In table 10.3_1 the heading of the 1st column is referring to XD-LAB actor Change this heading to " APSR Actor Vol. 3, section

More information

Laboratory- Clinical Communica1ons LCC Profile

Laboratory- Clinical Communica1ons LCC Profile Laboratory- Clinical Communica1ons LCC Profile IHE Laboratory Domain College of American Pathologists Jim Harrison, Univ. of Virginia The Problem The tradi1onal order- result paradigm does not include

More information

Pacific Knowledge Systems RippleDown User Guide: Administrator

Pacific Knowledge Systems RippleDown User Guide: Administrator Pacific Knowledge Systems RippleDown User Guide: Administrator This document focuses on the options and tasks available to RippleDown administrators and how to utilise these tools. Copyright Notice The

More information

Candelis, Inc. ImageGrid HL7 Conformance Statement Von Karman Ave. Newport Beach, CA Phone: Fax: Version 3.1.

Candelis, Inc. ImageGrid HL7 Conformance Statement Von Karman Ave. Newport Beach, CA Phone: Fax: Version 3.1. 4701 Von Karman Ave Newport Beach, CA 92660 Phone: 800.800.8600 Fax: 949.752.7317 Candelis, Inc. ImageGrid HL7 Conformance Statement Version 3.1.0 Copyright 2017 Candelis, Inc. Issued in U.S.A. http://www.candelis.com

More information

HL7 Interface Specification Merge RadSuite v

HL7 Interface Specification Merge RadSuite v Interface Specification Merge RadSuite v. 8.30.1 Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 877.44.MERGE Copyright 2011 Merge Healthcare. All rights reserved. This document, the information

More information

Results Reporting Interface Specifications For Results Sent from IntelliPath

Results Reporting Interface Specifications For Results Sent from IntelliPath The standard format for sending patient related information from one system to another is the HL7 (Health Level Seven) protocol. The HL7 protocol defines various types of messages that are composed of

More information

Slide 1. Slide 2. Slide 3. Component 9 - Networking and Health Information Exchange. Objectives. Why Use Data Interchange Standards?

Slide 1. Slide 2. Slide 3. Component 9 - Networking and Health Information Exchange. Objectives. Why Use Data Interchange Standards? Slide 1 Component 9 - Networking and Health Information Exchange Unit 5-1 - Health Data Interchange Standards This material was developed by Duke University, funded by the Department of Health and Human

More information

IHE Radiology Technical Framework Supplement. Clinical Decision Support Order Appropriateness Tracking (CDS-OAT) Rev. 1.3 Trial Implementation

IHE Radiology Technical Framework Supplement. Clinical Decision Support Order Appropriateness Tracking (CDS-OAT) Rev. 1.3 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Clinical Decision Support Order Appropriateness Tracking (CDS-OAT) 15 Rev. 1.3 Trial Implementation 20 Date: July

More information

IHE Cardiology Technical Framework Supplement. Evidence Documents Profile. Cardiology Options: Stress Testing CT/MR Angiography

IHE Cardiology Technical Framework Supplement. Evidence Documents Profile. Cardiology Options: Stress Testing CT/MR Angiography Integrating the Healthcare Enterprise 5 IHE Cardiology Technical Framework Supplement Evidence Documents Profile 10 Cardiology Options: Stress Testing CT/MR Angiography 15 Trial Implementation Date: October

More information

OtoAccess HL7 Interface. HL7 Specification

OtoAccess HL7 Interface. HL7 Specification OtoAccess HL7 Interface HL7 Specification SPO - 18/07/2012 Contents Usage guide for OtoAccess HL7 Interface 1 Introduction... 2 2 QRY/ADR Patient Query (Event A19)... 2 2.1 QRY_A19... 2 2.1.1 Sample message:

More information

Storage Peak. Version 5.3. HL7 Interface Specification

Storage Peak. Version 5.3. HL7 Interface Specification Storage Peak Version 5.3 HL7 Interface Specification Product: StoragePeak Version 5.1 Version 04.02 Document: HL7 Interface Specification 2013-07-11 Contents 1.INTRODUCTION... 2 1.1Revision History...

More information

Adding EHR-S FM components

Adding EHR-S FM components Adding EHR-S FM components This document describes the way new components, sections, headers, functions and/ or conformance criteria can be add to a Functional Model or Profile with support of the EHR-S

More information

HL7 Conformance Statement

HL7 Conformance Statement HL7 Conformance Statement Product Image-Arena 4.6 (or higher) Product No.: T.08.0122-09 (or higher) Originator: Document rev.: 09 Stefan Frohnapfel D.32.0083-09 HL7 Conformance Table of contents 1 GENERAL

More information

Jovanka N. Harrison, Ph.D., Chair For the NAACCR Pathology Data Work Group, and the NAACCR Supplement WG/Task Force

Jovanka N. Harrison, Ph.D., Chair For the NAACCR Pathology Data Work Group, and the NAACCR Supplement WG/Task Force Jovanka N. Harrison, Ph.D., Chair For the NAACCR Pathology Data Work Group, and the NAACCR Supplement WG/Task Force North American Association of Central Cancer Registries Annual Conference Austin, Texas

More information

PRT segment use to support Unique Device Identifiers in the PCD Profiles

PRT segment use to support Unique Device Identifiers in the PCD Profiles PRT segment use to support Unique Device Identifiers in the PCD Profiles 3 PRT segment use to support Unique Device Identifiers in the PCD Profiles Because of the importance of the recently defined Unique

More information

IHE Radiology Technical Framework Supplement. Imaging Object Change Management Extension (IOCM Extension) Rev. 1.6 Trial Implementation

IHE Radiology Technical Framework Supplement. Imaging Object Change Management Extension (IOCM Extension) Rev. 1.6 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Imaging Object Change Management Extension (IOCM Extension) 15 Rev. 1.6 Trial Implementation 20 Date: July 14, 2017

More information

Laboratory Technical Framework

Laboratory Technical Framework GMSIH, HPRIM and JAHIS Integrating the Healthcare Enterprise Laboratory Technical Framework 10 Volume 2 (LTF-2) Transactions 20 Revision 1.2 Final Text February 27, 2005 Copyright 2003: GMSIH, HPRIM, IHE-J,

More information

DICOM Correction Item

DICOM Correction Item DICOM Correction Item Correction Number CP-668 Log Summary: Type of Modification Addition Name of Standard PS 3.3, 3.17 2006 Rationale for Correction The term axial is common in practice, but is incorrectly

More information

The NGAL Test Application Note for Abbott Architect c8000

The NGAL Test Application Note for Abbott Architect c8000 The NGAL Test Application Note for Abbott Architect c8 General parameters Name: NGAL Assay number: *1 Assay version: 1 Assay type: Photometric Assay availability: Enabled Cal version: 1 Reaction definition

More information

Ensuring Quality Terminology Mappings in Distributed SOA Environments

Ensuring Quality Terminology Mappings in Distributed SOA Environments Ensuring Quality Terminology Mappings in Distributed SOA Environments SOA in Healthcare Chicago Illinois April 16, 2008 Russell Hamm Informatics Consultant Apelon, Inc. 1 Outline Data standardization Goals

More information

IHE Radiology Technical Framework Volume 2 (IHE RAD TF-2) Transactions

IHE Radiology Technical Framework Volume 2 (IHE RAD TF-2) Transactions Integrating the Healthcare Enterprise IHE Radiology Technical Framework Volume 2 (IHE RAD TF-2) Transactions Revision 10.0 Final Text February 18, 2011 _ Contents 1 INTRODUCTION... 3 1.1 OVERVIEW OF TECHNICAL

More information

IHE Radiology Technical Framework Supplement. Import Reconciliation Workflow (IRWF.b) Rev Trial Implementation

IHE Radiology Technical Framework Supplement. Import Reconciliation Workflow (IRWF.b) Rev Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Import Reconciliation Workflow (IRWF.b) 15 Rev. 1.2 - Trial Implementation 20 Date: September 9, 2016 Author: IHE

More information

python-hl7 Documentation

python-hl7 Documentation python-hl7 Documentation Release 0.2.4 John Paulett August 18, 2014 Contents 1 Usage 3 2 MLLP network client - mllp_send 5 3 Contents 7 3.1 python-hl7 API..............................................

More information

Implementing Automated Pathology Report Case Identification In a Cancer Registry

Implementing Automated Pathology Report Case Identification In a Cancer Registry Implementing Automated Pathology Report Case Identification In a Cancer Registry Ann Griffin, PhD, CTR, UCSF Comprehensive Cancer Center San Francisco, California Chris Rogers C/NET Solutions Berkeley,

More information

IHE Radiology Technical Framework Supplement. Results Distribution (RD) Rev. 1.0 Draft for Public Comment

IHE Radiology Technical Framework Supplement. Results Distribution (RD) Rev. 1.0 Draft for Public Comment Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Results Distribution (RD) 15 Rev. 1.0 Draft for Public Comment 20 Date: June 21, 2017 Author: IHE Radiology Technical

More information

HL7 TOOLS NEWBORN SCREENING HEALTH IT GUIDE AND TOOLKIT

HL7 TOOLS NEWBORN SCREENING HEALTH IT GUIDE AND TOOLKIT HL7 TOOLS NEWBORN SCREENING HEALTH IT GUIDE AND TOOLKIT This publication was developed by J Michael Consulting, LLC, in cooperation with the Virginia Division of Consolidated Laboratory Services (DCLS)

More information

HL7 Conformance Claim

HL7 Conformance Claim HL7 Conformance Claim Vitrea Connection 7.0 February 20, 2018 Vital Images Incorporated 5850 Opus Parkway Suite 300 Minnetonka, MN USA 55343 Vital Images shall not be liable for errors contained herein

More information

HL7 Conformance Claim

HL7 Conformance Claim HL7 Conformance Claim VioArchive 2.7 September 28, 2017 Vital Images Incorporated 5850 Opus Parkway Suite 300 Minnetonka, MN USA 55343 Vital Images shall not be liable for errors contained herein or for

More information

Beckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117

Beckman Coulter System Reagent, AU400/AU400 e URINE CALCIUM ARSENAZO Cat. No.: OSR6x117 Reagent ID: 117 Beckman Coulter System Reagent, AU400/AU400 e Test Name: CALA Type: Urine Operation: Yes Sample: Volume 2.0 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 25 L Dilution 225 L Min OD Max OD R2

More information

Beckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021

Beckman Coulter System Reagent, AU400/AU400 e URINE GLUCOSE Cat. No.: OSR6x21 Reagent ID: 021 Beckman Coulter System Reagent, AU400/AU400 e Test Name: GLU Type: Urine Operation: Yes Sample: Volume 3 L Dilution 0 L Pre-Dilution Rate: 1 Reagents: R1 Volume 50 L Dilution 150 L Min OD Max OD R2 Volume

More information

Clarification of HL7 V2 Conformance Profile Usage Codes and their Relationship to Testing

Clarification of HL7 V2 Conformance Profile Usage Codes and their Relationship to Testing Clarification of HL7 V2 Conformance Profile Usage Codes and their Relationship to ing For improving Meaningful Use HL7 V2 ing understanding UPDATED with comments from I/C Cambridge Meeting Robert Snelick,

More information

HIMSS and RSNA Integrating the Healthcare Enterprise IHE/MESA Image Manager/Archive Tests

HIMSS and RSNA Integrating the Healthcare Enterprise IHE/MESA Image Manager/Archive Tests HIMSS and RSNA Integrating the Healthcare Enterprise IHE/MESA Image Manager/Archive Tests Electronic Radiology Laboratory Mallinckrodt Institute of Radiology 510 South Kingshighway Blvd. St. Louis, MO

More information

Beckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078

Beckman Coulter System Reagent, AU400/AU400 e URINE CREATININE Cat. No.: OSR6x78 Reagent ID: 078 Beckman Coulter System Reagent, AU400/AU400 e Test Name: CRE < > Type: Urine Operation: Yes Sample: Volume 8 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 120 μl Dilution 90 μl Min OD Max OD

More information

IHE Pharmacy Technical Framework Supplement. Rev. 1.7 Trial Implementation

IHE Pharmacy Technical Framework Supplement. Rev. 1.7 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Pharmacy Technical Framework Supplement 10 Community Medication and Dispense (CMPD) 15 Rev. 1.7 Trial Implementation 20 Date: October 11, 2017 Author: IHE Pharmacy

More information

HL7 Conformance Statement for Image Management Family of Products: vnaplus and imagegateway

HL7 Conformance Statement for Image Management Family of Products: vnaplus and imagegateway HL7 Conformance Statement for Image Management Family of Products: vnaplus and imagegateway Doc#: 20120106.1 Last updated: July 05, 2018 Copyright Leafsprout Technologies Inc. Page 1 This page is blank

More information

SNOMED CT, FHIR, and more

SNOMED CT, FHIR, and more SNOMED CT, FHIR, and more François Macary Phast-Services: manager of international projects IHE International: co-chair of Pathology and Laboratory Medicine (PaLM) committee Interop Santé: chair of HL7

More information

Problem Set 4: Streams and Lazy Evaluation

Problem Set 4: Streams and Lazy Evaluation Due Friday, March 24 Computer Science (1)21b (Spring Term, 2017) Structure and Interpretation of Computer Programs Problem Set 4: Streams and Lazy Evaluation Reading Assignment: Chapter 3, Section 3.5.

More information

MT at NetApp This is how we do it

MT at NetApp This is how we do it MT at NetApp This is how we do it Edith Bendermacher Pablo Vázquez October 2015 Proceedings of MT Summit XV, vol. 2: MT Users' Track Miami, Oct 30 - Nov 3, 2015 p. 1 1 Agenda 1) The journey of quality

More information

Laboratory Code Set Distribution (LCSD)

Laboratory Code Set Distribution (LCSD) GMSIH, HL7 France H, HL7 Germany, IHE-J, JAHIS, SFIL, IHE Italy Integrating the Healthcare Enterprise IHE Laboratory Technical Framework Supplement 2004-2005 10 Laboratory Code Set Distribution (LCSD)

More information

SPECIFICATION FINAL. Electronic Medical Records. Appendix E EMR/OLIS Interface Requirements. OntarioMD Inc. Date: January 17, 2011 Version: 4.

SPECIFICATION FINAL. Electronic Medical Records. Appendix E EMR/OLIS Interface Requirements. OntarioMD Inc. Date: January 17, 2011 Version: 4. OntarioD Inc. Electronic edical Records SPECIFICATIO Appendix E ER/OLIS Interface Requirements FIAL Date: January 17, 2011 Version: 4.0 2007-2011 OntarioD Inc. All rights reserved TABLE OF COTETS 1. ITRODUCTIO...

More information

Standards for Cancer Registries Volume V: Pathology Laboratory Electronic Reporting Supplement Version 1

Standards for Cancer Registries Volume V: Pathology Laboratory Electronic Reporting Supplement Version 1 North American Association of Central Cancer Registries, Inc. Standards for Cancer Registries Volume V: Pathology Laboratory Electronic Reporting Supplement Version 1 Edited by Lori A. Havener Suggested

More information

IHE Radiology Technical Framework Supplement. Multiple Image Manager/Archive (MIMA) Trial Implementation

IHE Radiology Technical Framework Supplement. Multiple Image Manager/Archive (MIMA) Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement Multiple Image Manager/Archive (MIMA) 10 Trial Implementation 15 20 Date: September 30, 2010 Author: David Heaney Email:

More information

IHE Endoscopy Technical Framework Supplement. Endoscopy Image Archiving (EIA) Rev. 1.1 Trial Implementation

IHE Endoscopy Technical Framework Supplement. Endoscopy Image Archiving (EIA) Rev. 1.1 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Endoscopy Technical Framework Supplement 10 Endoscopy Image Archiving (EIA) 15 Rev. 1.1 Trial Implementation 20 Date: November 28, 2018 Author: IHE Endoscopy

More information

IHE Laboratory (LAB) Technical Framework. Volume 2 (LAB TF-2) Transactions

IHE Laboratory (LAB) Technical Framework. Volume 2 (LAB TF-2) Transactions Integrating the Healthcare Enterprise 5 IHE Laboratory (LAB) Technical Framework 10 Volume 2 (LAB TF-2) Transactions 15 Revision 3.0 Final Text May 19, 2011 20 25 30 35 40 45 50 55 60 65 70 Contents: 1

More information

MINNESOTA DEPARTMENT OF HEALTH ELECTRONIC LABORATORY REPORTING (ELR)

MINNESOTA DEPARTMENT OF HEALTH ELECTRONIC LABORATORY REPORTING (ELR) MINNESOTA DEPARTMENT OF HEALTH ELECTRONIC LABORATORY REPORTING (ELR) MDH Implementation guide for ELR v2.0 Date: MDH-ELR OLF 2C, 625 Robert St N P.O Box 64975 Saint Paul, MN 55164 Email: Health.MDHELR@state.mn.us

More information

GET-IT Specifications v External Documentation v1.01 powered by DXTi

GET-IT Specifications v External Documentation v1.01 powered by DXTi GET-IT Specifications v1.01.003 External Documentation v1.01 powered by DXTi This document contains information relating to the formatting and structure of the base GDML results HL7 specification for external

More information

Electronic Laboratory Reporting - Format

Electronic Laboratory Reporting - Format Overview The CDC s Implementation Guide for Transmission of Laboratory-Based Reporting of Public Health Information using Version 2.3.1 of the HL7 Standard Protocol dated April 21, 2003 and the HL7 Version

More information

IHE Eye Care Technical Framework Supplement. Unified Eye Care Workflow Refractive Measurements. Rev. 1.2 Trial Implementation

IHE Eye Care Technical Framework Supplement. Unified Eye Care Workflow Refractive Measurements. Rev. 1.2 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Eye Care Technical Framework Supplement 10 Unified Eye Care Workflow Based upon JOIA 1.5 Release 15 Rev. 1.2 Trial Implementation 20 Date: June 29, 2016 Author:

More information

Data Anonymisation and Transformation Testing Process - TSFT to Deepmind

Data Anonymisation and Transformation Testing Process - TSFT to Deepmind Data Anonymisation and Transformation Testing Process - TSFT to Deepmind Taunton & Somerset NHS Foundation Trust Document Control This document is available in two forms, controlled and uncontrolled. The

More information

CAUTION: NEVER LOOK DIRECTLY INTO THE LASER BEAM.

CAUTION: NEVER LOOK DIRECTLY INTO THE LASER BEAM. LABORATORY 12 PHYSICAL OPTICS I: INTERFERENCE AND DIFFRACTION Objectives To be able to explain demonstrate understanding of the dependence of a double slit interference pattern on slit width, slit separation

More information

Timestamping and Time Synchronization

Timestamping and Time Synchronization A.1.1 Timestamping and Time Synchronization Timestamps associated with observations sent over the Continua WAN shall be referenced to a single consistent Coordinated Universal Time (UTC) timeline to facilitate

More information

Fundamentals, Design, and Implementation, 9/e Copyright 2004 Database Processing: Fundamentals, Design, and Implementation, 9/e by David M.

Fundamentals, Design, and Implementation, 9/e Copyright 2004 Database Processing: Fundamentals, Design, and Implementation, 9/e by David M. Chapter 5 Database Design Elements of Database Design Fundamentals, Design, and Implementation, 9/e Chapter 5/2 The Database Design Process Create tables and columns from entities and attributes Select

More information

IHE EYECARE Technical Framework Supplement

IHE EYECARE Technical Framework Supplement Integrating the Healthcare Enterprise IHE EYECARE Technical Framework Supplement Extensions to the Eye Care Workflow Integration Profile Public Comment Date: April 30, 2009 Author: Don Van Syckle Email:

More information

IHE Patient Care Device (PCD) Technical Framework. Volume 2 IHE PCD TF-2 Transactions

IHE Patient Care Device (PCD) Technical Framework. Volume 2 IHE PCD TF-2 Transactions Integrating the Healthcare Enterprise 5 IHE Patient Care Device (PCD) Technical Framework 10 Volume 2 IHE PCD TF-2 Transactions 15 20 Revision 7.0 - Final Text November 9, 2017 25 Please verify you have

More information

IHE Radiology Technical Framework Supplement. Scheduled Workflow.b (SWF.b) Trial Implementation

IHE Radiology Technical Framework Supplement. Scheduled Workflow.b (SWF.b) Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Scheduled Workflow.b (SWF.b) 15 Trial Implementation 20 Date: July 30, 2014 Author: IHE Radiology Technical Committee

More information

IHE EYECARE Technical Framework Supplement

IHE EYECARE Technical Framework Supplement Integrating the Healthcare Enterprise IHE EYECARE Technical Framework Supplement Extensions to the Eye Care Workflow Integration Profile Trial Implementation Date: June 12, 2009 Author: Email: Don Van

More information

CAIR2 HL7 v2.5.1 Bi-Directional (QBP/RSP) Data Exchange Implementation Guide

CAIR2 HL7 v2.5.1 Bi-Directional (QBP/RSP) Data Exchange Implementation Guide CAIR2 HL7 v2.5.1 Bi-Directional (QBP/RSP) Data Exchange Implementation Guide California Immunization Registry Version 1.02 Consistent with HL7 Version 2.5.1 Implementation Guide for Immunization Messaging,

More information

IHE Radiology (RAD) Technical Framework. Volume 3 IHE RAD TF-3 Transactions (continued)

IHE Radiology (RAD) Technical Framework. Volume 3 IHE RAD TF-3 Transactions (continued) Integrating the Healthcare Enterprise 5 IHE Radiology (RAD) Technical Framework 10 Volume 3 IHE RAD TF-3 Transactions (continued) 15 20 Revision 16.0 Final Text August 4, 2017 25 Please verify you have

More information

Beckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524

Beckman Coulter System Reagent, AU400/AU400 e ETHYL ALCOHOL EMIT II PLUS Cat. No.: OSR9K229 Reagent ID: 524 Beckman Coulter System Reagent, AU400/AU400 e Test Name: ETOH+ < > Type: Urine Operation: Yes Sample: Volume 4 μl Dilution 0 μl Pre-Dilution Rate: 1 Reagents: R1 Volume 210 μl Dilution 0 μl Min OD Max

More information

IHE Patient Care Device Technical Framework Supplement. Point-of-Care Identity Management (PCIM) Revision 1.1 Trial Implementation

IHE Patient Care Device Technical Framework Supplement. Point-of-Care Identity Management (PCIM) Revision 1.1 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Patient Care Device Technical Framework Supplement 10 Point-of-Care Identity Management (PCIM) 15 Revision 1.1 Trial Implementation 20 Date: December 7, 2018

More information

Healthcare Claim Attachment Overview and Progress. HIPAA Summit West II San Francisco, CA March 13, 2002

Healthcare Claim Attachment Overview and Progress. HIPAA Summit West II San Francisco, CA March 13, 2002 Healthcare Claim Attachment Overview and Progress HIPAA Summit West II San Francisco, CA March 13, 2002 Claim Attachments Overview and Progress Presented by: Gale Carter fp Technologies, Inc. Co Chair

More information

IHE Patient Care Device (PCD) Technical Framework. Volume 2 IHE PCD TF-2 Transactions

IHE Patient Care Device (PCD) Technical Framework. Volume 2 IHE PCD TF-2 Transactions Integrating the Healthcare Enterprise 5 IHE Patient Care Device (PCD) Technical Framework 10 Volume 2 IHE PCD TF-2 Transactions 15 20 Revision 5.0 - Final Text October 14, 2015 25 Please verify you have

More information

IHE Radiology Technical Framework Supplement. Cross-Enterprise Remote Read Workflow Definition (XRR-WD) Rev. 1.1 Trial Implementation

IHE Radiology Technical Framework Supplement. Cross-Enterprise Remote Read Workflow Definition (XRR-WD) Rev. 1.1 Trial Implementation Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Cross-Enterprise Remote Read Workflow Definition (XRR-WD) 15 Rev. 1.1 Trial Implementation 20 Date: January 13, 2017

More information

Workshop 2. > Interoperability <

Workshop 2. > Interoperability < Workshop 2 21 / 08 / 2011 > Interoperability < Heiko Zimmermann R&D Engineer, AHI CR Santec Heiko.Zimmermann@tudor.lu Interoperability definition Picture from NCI-Wiki (https://wiki.nci.nih.gov) 2 Interoperability

More information

PROTECTION. Vishwas Patil. Dipartimento di Informatica Universitá degli Studi di Roma La Sapienza Via Salaria 113, Roma, Italy

PROTECTION. Vishwas Patil. Dipartimento di Informatica Universitá degli Studi di Roma La Sapienza Via Salaria 113, Roma, Italy Dipartimento di Informatica Universitá degli Studi di Roma La Sapienza Via Salaria 113, 00198 Roma, Italy http://www.dsi.uniroma1.it/ patil Protection? A mechanism to control the access Protection? A mechanism

More information

2003 LXI H, 42F2H ; this instruction store 42F2 in to the HL pair POP H ; store data from top of the stack to HL pair

2003 LXI H, 42F2H ; this instruction store 42F2 in to the HL pair POP H ; store data from top of the stack to HL pair (1) What is stack? Explain stack related instruction with example OR Give function of stack. OR What is stack? Explain the stack operations using examples. The stack is a group of memory location in the

More information

TMY PACS HL7 Conformance Statement

TMY PACS HL7 Conformance Statement Rev.: 01 Pg. 1 of 7 Written or Updated by: Name Title Date Signature Erdal Orak technical department 11-v-2013 Rev.: 01 Pg. 2 of 7 Contents 1. INTRODUCTION... 3 1.1. Purpose and Intended Audience of this

More information

Master the implementation and management of a Cybersecurity Program based on ISO/IEC 27032

Master the implementation and management of a Cybersecurity Program based on ISO/IEC 27032 Master the implementation and management of a Program based on ISO/IEC 27032 Why should you attend? Manager training enables you to acquire the expertise and competence needed to support an organization

More information

Merge HL7 Toolkit Segment Map User Interface (UI) Sample Application Guide v.4.7.0

Merge HL7 Toolkit Segment Map User Interface (UI) Sample Application Guide v.4.7.0 OM Toolkit Merge HL7 Toolkit Segment Map User Interface (UI) Sample Application Guide v.4.7.0 Merge Healthcare 200 E. Randolph Street, Chicago, IL USA, 60601 877.44.MERGE Copyright 2012 Merge Healthcare

More information

Ritsumeikan University Researcher s Database Batch Registration Manual

Ritsumeikan University Researcher s Database Batch Registration Manual Ver. 2013.3.1 Ritsumeikan University Researcher s Database Batch Registration Manual The new Researcher s Database is complete. This Batch Registration manual is to be used as a reference when conducting

More information

Interfacing the PACS and the HIS: Results of a 5-year Implementation

Interfacing the PACS and the HIS: Results of a 5-year Implementation inforad Interfacing the PACS and the HIS: Results of a 5-year Implementation 1 883 Thomas V. Kinsey, MEd, BSRT, RT(R) Maria C. Horton, MSN Tom E. Lewis, MSE An interface was created between the Department

More information

This document describes the command line interface (CLI) functionality provided in the Application Framework for RF4CE-based applications.

This document describes the command line interface (CLI) functionality provided in the Application Framework for RF4CE-based applications. APPLICATION FRAMEWORK COMMAND LINE INTERFACE FOR RF4CE This document describes the line interface (CLI) functionality provided in the Application Framework for RF4CE-based applications. New in This Revision

More information

Find-A-Code Finding Codes Table of Contents

Find-A-Code Finding Codes Table of Contents Find-A-Code Finding Codes Table of Contents General Introduction...2 Using Find-A-Code Search...3 Using Click-A-Dex...7 Using Build-A-Code...9 Using Browse-A-Code...11 Using Cross-A-Code...14 General Introduction

More information

MyCodingTools Finding Codes Table of Contents

MyCodingTools Finding Codes Table of Contents MyCodingTools Finding Codes Table of Contents General Introduction...2 Using MyCodingTools Search...3 Using Click-A-Dex...7 Using Build-A-Code...9 Using Browse-A-Code...12 Using Cross-A-Code...15 General

More information

40 AND 100 GIGABIT ETHERNET TESTING SERVICE

40 AND 100 GIGABIT ETHERNET TESTING SERVICE 40 AND 100 GIGABIT ETHERNET TESTING SERVICE Clause 95 100GBASE-SR4 PMD Test Plan Version 1.1 Technical Document Last Updated: January 23, 2018 40 and 100 Gigabit Ethernet Testing Service 21 Madbury Road,

More information

Robert Snelick, NIST Sheryl Taylor, BAH. October 11th, 2012

Robert Snelick, NIST Sheryl Taylor, BAH. October 11th, 2012 Test Tool Orientation for International Society for Disease Surveillance (ISDS): 2014 Edition 170.314(f)(3) Transmission to Public Health Agencies - Syndromic Surveillance Robert Snelick, NIST Sheryl Taylor,

More information

Designing robust and reliable timestamps for remote patient monitoring

Designing robust and reliable timestamps for remote patient monitoring Designing robust and reliable timestamps for remote patient monitoring Malcolm Clarke, Senior Member, IEEE, Paul Schluter, Member, IEEE, Barry Reinhold, Member, IEEE, and Brian Reinhold, Member, IEEE Abstract

More information

Using SNOMED CT in an International Clinical Information System

Using SNOMED CT in an International Clinical Information System Using SNOMED CT in an International Clinical Information System RN- BC, MSN, MSCS Principal Scientist, Clinical Software Architect Philips Healthcare Objectives Describe the benefits of using SNOMED CT

More information

IHE Cardiology Technical Framework Supplement. Stress Testing Workflow (STRESS) Trial Implementation

IHE Cardiology Technical Framework Supplement. Stress Testing Workflow (STRESS) Trial Implementation Integrating the Healthcare Enterprise 5 IHE Cardiology Technical Framework Supplement 10 Stress Testing Workflow (STRESS) 15 Trial Implementation 20 Date: August 29, 2013 Author: IHE Cardiology Technical

More information

Hash Tables. Hashing Probing Separate Chaining Hash Function

Hash Tables. Hashing Probing Separate Chaining Hash Function Hash Tables Hashing Probing Separate Chaining Hash Function Introduction In Chapter 4 we saw: linear search O( n ) binary search O( log n ) Can we improve the search operation to achieve better than O(

More information

IHE Radiology Technical Framework Supplement. Import Reconciliation Workflow (IRWF.b) Trial Implementation

IHE Radiology Technical Framework Supplement. Import Reconciliation Workflow (IRWF.b) Trial Implementation Integrating the Healthcare Enterprise 5 10 IHE Radiology Technical Framework Supplement Import Reconciliation Workflow (IRWF.b) 15 Trial Implementation 20 Date: June 15, 2012 25 Authors: Email: David Heaney

More information

Health Engine HL7 Conformance Statement. Internal document number: Date:

Health Engine HL7 Conformance Statement. Internal document number: Date: Health Engine HL7 Conformance Statement Version: 1.0 Rev A Internal document number: 31011234711 Date: 20160530 the i-engineers AG May 2016 Abstract Manufacturer Support This document provides information

More information

LAB INFORMATION SYSTEMS MESSAGE STANDARD SUMMARY

LAB INFORMATION SYSTEMS MESSAGE STANDARD SUMMARY Health Information Messaging Specification HEALTH INFORMATION STANDARDS COMMITTEE FOR ALBERTA LAB INFORMATION SYSTEMS MESSAGE STANDARD SUMMARY HL7 V2.4 LAB TEST RESULT DELIVERY SPECIFICATION AND HL7V3

More information