1 V 2.6 Revised /8/8 RTD Temperature EZO Circuit Reads Temperature Range C 254 C Resolution 0.00 Accuracy +/ (0.0 C x C) Max rate Supported probes Calibration Temperature output Data protocol Default I 2 C address Operating voltage Data format reading per sec Any type & brand PT-00 or PT-000 RTD Single point C, K, or F UART & I 2 C 02 (0x66) 3.3V 5.5V ASCII Electrical Isolation not needed Onboard Data Logger 50 Readings Written by Jordan Press Designed by Noah Press This is an evolving document, check back for updates.

2 This is sensitive electronic equipment. Get this device working in a solderless breadboard first. Once this device has been soldered it is no longer covered by our warranty. This device has been designed to be soldered and can be soldered at any time. Once that decision has been made, Atlas Scientific no longer assumes responsibility for the device s continued operation. The embedded systems engineer is now the responsible party. Get this device working in a solderless breadboard first! Do not embed this device without testing it in a solderless breadboard! A B C D E A B C D E F G H I J F G H I J

3 Table of contents Circuit dimensions Power consumption Absolute max ratings Temperature circuit range Temperature circuit accuracy Atlas Scientific PT-000 probe Using other brand PT-00/PT-000 Operating principle Calibration theory On board data logger Correct wiring Available data protocols UART I 2 C UART mode Default state Receiving data from device Sending commands to device LED color definition UART quick command page LED control Find Continuous reading mode Single reading mode Calibration Export/import calibration Temperature scale Enable/disable data logger Memory recall Memory clear Naming device Device information codes Reading device status Sleep mode/low power Change baud rate Protocol lock Factory reset Change to I 2 C mode Manual switching to I 2 C I 2 C mode Sending commands Requesting data codes LED color definition I 2 C quick command page LED control Find Taking reading Calibration Export/import calibration Temperature scale Enable/disable data logger Memory recall Memory clear Device information Reading device status Sleep mode/low power Protocol lock I 2 C address change Factory reset Change to UART mode Manual switching to UART Circuit footprint Datasheet change log Warranty Copyright Atlas Scientific LLC

4 EZO TM circuit dimensions 3.97mm (0.55 ) 20.6mm (0.79 ) 5.8mm (0.22 ) 8.38mm (0.32 ) 0.8mm (0.4 ) Power consumption Absolute max ratings LED MAX STANDBY SLEEP Parameter MIN TYP MAX 5V 3.3V ON 6 ma 5.4 ma OFF 5.3 ma 5 ma ON 4.3 ma 3.8 ma 0.4 ma 0.09 ma Storage temperature (EZO RTD) Operational temperature (EZO RTD) -65 C 25 C -40 C 25 C 85 C OFF 4 ma 3.6 ma VCC 3.3V 5V 5.5V 4 Copyright Atlas Scientific LLC

5 EZO TM RTD temperature circuit range 000 C 500 C 0 C -26 C 0 C 200 C 400 C 600 C 800 C,000 C,254 C EZO TM RTD temperature circuit accuracy 2 C 0 C -2 C -26 C 0 C 200 C 400 C 600 C 800 C,000 C,254 C 5 Copyright Atlas Scientific LLC

6 Atlas Scientific PT-000 probe Accuracy +/- (0.5 + (0.002*t)) Probe type: class A platinum, RTD Cable length: 8cm (32") Cable material: silicone rubber 30mm sensing area (304 SS) 6mm diameter BNC connector Reaction time: 90% value in 3 seconds Probe output: analog Full sensing range -200 C to 850 C Cable max temp 25 C Cable min temp -55 C The Atlas Scientific EZO RTD Temperature circuit only works with PT-00 and PT-000 probes. To read temperatures above, or below the max cable temperature, an additional probe housing (thermowell) is needed to protect the cable. 00mm Temperature Thermowell 50mm Temperature Thermowell 30mm Temperature Thermowell 6 Copyright Atlas Scientific LLC

7 Using other brand PT-00/PT-000 The EZO RTD Temperature circuit will auto-detect if the connected probe is PT-00 or PT-000. Probe class Accuracy AA +/- (0.0 C x T) A +/- (0.5 C x T) B +/-(0.3 C x T) C +/- (0.6 C x T) It makes no difference which lead of the temperature probe is connected to the two probe pins. 7 Copyright Atlas Scientific LLC

8 Operating principle The Atlas Scientific EZO RTD Temperature circuit is a small footprint computer system that is specifically designed to be used in robotic applications where the embedded systems engineer requires accurate and precise measurements of temperature through a generic PT-00/PT-000 temperature probe. RTD = Resistance Temperature Detector PT = Platinum PT-00 = 00 Ω at 0 C PT-000 = k Ω at 0 C Unlike any other material, platinums correlation between resistance and temperature seems to be woven into the fabric of the universe. It is for this reason, that the platinum RTD temperature sensor is the industrial standard for temperature measurement. Resistance Nickel 78 Pt Platinum Copper Platinum Temperature ºC 8 Copyright Atlas Scientific LLC

9 Calibration theory Calibration can be done at any value, a simple method is to calibrate the probe in boiling water. 00 C Atlas Scientific recommends calibration be done every three years. Elevation and Boiling Point table Elevation in meters Boiling point C C C C C C C Use purified/distilled water For accurate calibration using different temperature vaules, you must use a tool called a "dry block calibrator." 9 Copyright Atlas Scientific LLC

10 On board data logger 50 readings Programmable storage interval Minimum 0 seconds Maximum 320,000 seconds Temperature readings that are stored to the data logger will be retained even if the power is cut When memory becomes full, the data logger will overwrite memory location Copyright Atlas Scientific LLC

11 A B C D E F G H I J A B C D E F G H I J A B C D E F G H I J A B C D E F G H I J ELECTRICAL ISOLATION IS NOT NEEDED. Power and data isolation Copyright Atlas Scientific LLC

12 TM Correct wiring Bread board Bread board via USB Carrier board USB carrier board A B C D E A B C D E A B C D E A B C D E VCC GND TX RX PWR RX TX F G H I J F G H I J F G H I J F G H I J Atlas Scientific Part # COM-04 Part # ISCCB Part # USB-ISO Incorrect wiring Extended leads Sloppy setup Perfboards or Protoboards *Embedded into your device A B C D E F G H I J NEVER use Perfboards or Protoboards *Only after you are familar with EZO TM circuits operation A B C D E F G H I J 2 Copyright Atlas Scientific LLC

13 Available data protocols Default Unavailable data protocols SPI Analog RS-485 Mod Bus 4 20mA 3 Copyright Atlas Scientific LLC

14 UART mode Settings that are retained if power is cut Baud rate Calibration Continuous mode Device name Enable/disable response codes Hardware switch to I 2 C mode LED control Protocol lock Software switch to I 2 C mode Settings that are NOT retained if power is cut Find Sleep mode 0.2

15 UART mode 8 data bits stop bit Baud RX Data in no parity no flow control 300,200 2,400 9,600 default 9,200 38,400 57,600 5,200 TX RX RX TX TX Data out Vcc 3.3V 5.5V TX RX CPU VCC 0V 0V Data format Reading temperature Units C, K, or F Encoding ASCII Format string Terminator carriage return Data type floating point Decimal places 3 Smallest string 4 characters Largest string 399 characters 5 Copyright Atlas Scientific LLC

16 Default state Mode Baud Temperature Readings Speed With probe Without probe LED UART 9,600 C continuous reading per second ttt.ttt on,000 ms Green Standby Cyan Taking reading Transmitting 6 Copyright Atlas Scientific LLC

17 Receiving data from device 2 parts ASCII data string Command Carriage return Terminator 9,600 baud (default) TX RX CPU Receiver Sender Advanced ASCII: Hex: E D Dec: Copyright Atlas Scientific LLC

18 Sending commands to device 2 parts Command (not case sensitive) ASCII data string Carriage return Terminator TX RX CPU Sleep Sender Receiver Advanced ASCII: S l e e p Hex: 53 6C D Dec: Copyright Atlas Scientific LLC

19 LED color definition Green UART standby Cyan Taking reading Purple Changing baud rate Red Command not understood White Find 5V LED ON +0.4 ma 3.3V +0.2 ma 9 Copyright Atlas Scientific LLC r 0.2

20 UART mode command quick reference All commands are ASCII strings or single ASCII characters. Command Function Default state Baud change baud rate pg. 36 9,600 C enable/disable continuous reading pg. 23 enabled Cal performs calibration pg. 25 n/a D enable/disable data logger pg. 28 disabled Export/import export/import calibration pg. 26 n/a Factory enable factory reset pg. 38 n/a Find finds device with blinking white LED pg. 22 n/a i device information pg. 32 n/a I2C change to I 2 C mode pg. 39 not set L enable/disable LED pg. 2 enabled M memory recall/clear pg. 29 n/a Name set/show name of device pg. 3 not set Plock enable/disable protocol lock pg. 37 disabled R returns a single reading pg. 24 n/a S temperature scale ( C, K, F) pg. 27 celsius Sleep enter sleep mode/low power pg. 35 n/a Status retrieve status information pg. 34 n/a *OK enable/disable response codes pg. 33 enable 20 Copyright Atlas Scientific LLC

21 LED control L, L,0 LED off L,? LED on default LED state on/off? L, *OK L,0 *OK L,??L, or?l,0 *OK L, L,0 2 Copyright Atlas Scientific LLC

22 Find This command will disable continuous mode Send any character or command to terminate find. Find LED rapidly blinks white, used to help find device* *This command is only available for firmware version 2.0 and above. Find *OK 22 Copyright Atlas Scientific LLC

23 Continuous reading mode C, C,n C,0 disable continuous readings C,? enable continuous readings once per second default continuous readings every n seconds (n = 2 to 99 sec)* continuous reading mode on/off? *This command is only available for firmware version 2.0 and above. C, *OK C ( sec) C (2 sec) C (n sec) C,30 *OK C (30 sec) C (60 sec) C (90 sec) C,0 *OK C,??C, or?c,0 or?c,30 *OK 23 Copyright Atlas Scientific LLC r 0.2

24 Single reading mode R takes single reading R *OK,000 ms Green Standby Cyan Taking reading Transmitting 600 ms 24 Copyright Atlas Scientific LLC

25 Calibration The EZO TM RTD circuit uses single point calibration. Cal,t Cal,clear Cal,? t = any temperature delete calibration data device calibrated? Cal,00.00 *OK Cal,clear *OK Cal,??Cal, *OK or?cal,0 Cal, C C 25 Copyright Atlas Scientific LLC

26 Export/import calibration Export: Use this command to save calibration settings Import: Use this command to load calibration settings to one or more devices. Export Import Export,? export calibration string from calibrated device* import calibration string to new device* calibration string info* *This command is only available for firmware version 2.0 and above. Export,? 0,20 breakdown 0, 20 # of strings to export # of bytes to export Export strings can be up to 2 characters long, and is always followed by Export Export (7 more) Export Export 59 6F ( of 0) F 6F 6C *DONE (2 of 0) (0 of 0) Disabling *OK simplifies this process Import, n (FIFO) Import, 59 6F ( of 0) 26 Copyright Atlas Scientific LLC

27 Temperature scale ( C, K, F) S,c S,k S,f S,? celsius default kelvin fahrenheit temperature scale? S,c *OK S,k *OK S,f *OK S,??S,c or?s,k or?s,f *OK -26 C,254 C (celsius) 47.5 K,527.5 K (kelvin) F 2,289.2 F (fahrenheit) 27 Copyright Atlas Scientific LLC

28 Enable/disable data logger The time period (n) is in 0 second intervals and can be any value from to 32,000. D,n D,0 disable D,? n = (n x 0 seconds) default data logger storage interval? D,6 *OK D,0 *OK D,??D,6 *OK D,6 60 seconds * * indicates reading has been logged 28 Copyright Atlas Scientific LLC

29 Memory recall Disable data logger to recall memory. M M,all M,? recall sequential stored reading recall all readings in a CSV string display memory location of last stored reading M, ,04.00 *OK M,all 00.00,04.00,08.00,2.00 Oldest Newest M,??M,4 *OK Copyright Atlas Scientific LLC

30 25 25 Memory clear M,clear clear all stored memory M,clear *OK M,clear Copyright Atlas Scientific LLC

31 Naming device Name,n Name,? set name show name n = Up to 6 ASCII characters Name,zzt *OK Name,??Name,zzt *OK Name,zzt Name,? *OK Name,zzt *OK 3 Copyright Atlas Scientific LLC

32 Device information i device information i?i,rtd,2.0 *OK breakdown?i, RTD, 2.0 Device Firmware 32 Copyright Atlas Scientific LLC

33 codes *OK, *OK,0 *OK,? enable response disable response response on/off? default R *OK *OK,0 no response, *OK disabled R *OK disabled *OK,??*OK, or?*ok,0 Other response codes *ER *OV *UV *RS *RE *SL *WA unknown command over volt (VCC>=5.5V) under volt (VCC<=3.V) reset boot up complete, ready entering sleep mode wake up These response codes cannot be disabled 33 Copyright Atlas Scientific LLC

34 Reading device status Status voltage at Vcc pin and reason for last restart Status?Status,P,5.038 *OK breakdown?status, P, Reason for restart Voltage at Vcc Restart codes P powered off S software reset B brown out W watchdog U unknown 34 Copyright Atlas Scientific LLC

35 Sleep mode/low power Send any character or command to awaken device. Sleep enter sleep mode/low power Sleep *SL Any command *WA wakes up device 5V STANDBY SLEEP 5.40 ma 0.4 ma 3.3V 3.80 ma 0.09 ma Sleep Standby 5.40 ma Sleep 3.00 ma 35 Copyright Atlas Scientific LLC

36 Change baud rate TX RX RX TX Baud,n change baud rate TX RX CPU Baud,38400 *OK Baud,??Baud,38400 *OK n = default Baud,38400 (reboot) Standby reen T standby Cyan Taking reading Changing baud rate Purple Changing *OK baud rate Red Command not understood Standby White Find 36 Copyright Atlas Scientific LLC

37 Protocol lock Locks device to UART mode. Plock, Plock,0 Plock,? enable Plock disable Plock Plock on/off? default Plock, *OK Plock,0 *OK Plock,??Plock, or?plock,0 Plock, I2C,00 Short *OK cannot change to I 2 C *ER cannot change to I 2 C 37 Copyright Atlas Scientific LLC Short

38 Factory reset Clears calibration LED on "*OK" enabled Clears data logger Factory enable factory reset Factory *OK Factory (reboot) *OK *RS *RE Baud rate will not change 38 Copyright Atlas Scientific LLC

39 Change to I 2 C mode Default I 2 C address 02 (0x66) I2C,n sets I 2 C address and reboots into I 2 C mode n = any number 27 I2C,00 *OK (reboot in I 2 C mode) Wrong example I2C,39 n > 27 *ER I2C,00 (reboot) Green *OK Blue now in I 2 C mode 39 Copyright Atlas Scientific LLC r 0.2

40 Manual switching to I 2 C Make sure Plock is set to 0 Disconnect ground (power off) Disconnect TX and RX Connect TX to PRB Confirm RX is disconnected Connect ground (power on) Wait for LED to change from Green to Blue Disconnect ground (power off) Reconnect all data and power Connecting TX to PRB only works for the EZO RTD Temperature circuit. Manually switching to I 2 C will set the I 2 C address to 02 (0x66) Short Wrong Short Disconnect RX line 40 Copyright Atlas Scientific LLC

41 I 2 C mode The I 2 C protocol is considerably more complex than the UART (RS 232) protocol. Atlas Scientific assumes the embedded systems engineer understands this protocol. To set your EZO TM device into I 2 C mode click here Settings that are retained if power is cut Calibration Change I 2 C address Hardware switch to UART mode LED control Protocol lock Software switch to UART mode Settings that are NOT retained if power is cut Find Sleep mode r 0.2

42 I 2 C mode I 2 C address (0x0 0x7F) 02 (0x66) default Vcc 3.3V 5.5V Clock speed khz VCC 4.7k resistor may be needed VCC VCC 0V 0V CPU Data format Reading temperature Units C, K, or F Encoding ASCII Format string Data type floating point Decimal places 3 Smallest string 4 characters Largest string 4 characters 42 Copyright Atlas Scientific LLC

43 Sending commands to device 5 parts Start I 2 C address Write Command (not case sensitive) Stop 20 (0x66) ASCII command string Start 02 (0x66) Write Sleep Stop I 2 C address Command CPU Advanced Address bits The entire command as ASCII with all arguments A6 A5 A4 A3 A2 A A0 W ACK First letter of command ACK Last letter of command ACK Start W = low Stop 43 Copyright Atlas Scientific LLC

44 Requesting data from device 7 parts Start I 2 C address Read code Data string Null Stop 02 (0x66) byte "25.04" Terminator (Dec 0) CPU Advanced Address bits N bytes of data All bytes after data are Null R = High A6 A0 R ACK code ACK Data ACK Data N ACK Null ACK Null Start NACK Stop Dec Dec ASCII = Copyright Atlas Scientific LLC

45 codes After a command has been issued, a byte response code can be read in order to confirm that the command was processed successfully. Reading back the response code is completely optional, and is not required for normal operation. Send command CPU Processing delay Receiving data I2C_start; I2C_address; I2C_write(EZO_command); I2C_stop; delay(300); I2C_start; I2C_address; Char[ ] = I2C_read; I2C_stop; Processing delay If there is no processing delay or the processing delay is too short, the response code will always be 254. codes Single byte, not string no data to send still processing, not ready error successful request 45 Copyright Atlas Scientific LLC

46 LED color definition Blue Green Purple Red White I 2 C standby Taking reading 5V LED ON +0.4 ma Changing I 2 C ID# Command not understood Find 3.3V +0.2 ma 46 Copyright Atlas Scientific LLC

47 I 2 C mode command quick reference All commands are ASCII strings or single ASCII characters. Command Baud Cal D Function switch back to UART mode performs calibration enable/disable data logger pg. 63 pg. 5 pg. 54 Export/import export/import calibration pg. 52 Factory Find i I2C L M Plock R S Sleep Status enable factory reset finds devices with white blinking LED device information change I 2 C address enable/disable LED memory recall/clear enable/disable protocol lock returns a single reading temperature scale ( C, K, F) enter sleep mode/low power retrieve status information pg. 62 pg. 49 pg. 57 pg. 6 pg. 48 pg. 55 pg. 60 pg. 50 pg. 53 pg. 59 pg Copyright Atlas Scientific LLC

48 LED control L, LED on default L,0 LED off L,? LED state on/off? 300ms processing delay L, Wait 300ms Dec 0 Null L,0 Wait 300ms Dec 0 Null L,? Wait 300ms?L, 0 Dec ASCII Null or?l,0 0 Dec ASCII Null L, L,0 48 Copyright Atlas Scientific LLC

49 Find 300ms processing delay This command will disable continuous mode Send any character or command to terminate find. Find LED rapidly blinks white, used to help find device* *This command is only available for firmware version 2.0 and above. Find Wait 300ms Dec 0 Null 49 Copyright Atlas Scientific LLC

50 Taking reading 600ms processing delay R return reading R Wait 600ms Dec ASCII 0 Null Green Taking reading Wait 600ms Transmitting Blue Standby 50 Copyright Atlas Scientific LLC

51 Calibration 600ms processing delay Cal,t Cal,clear Cal,? t = any temperature delete calibration data device calibrated? EZO TM RTD circuit uses single point calibration. Cal,t Wait 600ms Dec 0 Null Cal,clear Wait 300ms Dec 0 Null Cal,? Wait 300ms?Cal, Dec ASCII 0 Null or Dec?Cal,0 ASCII 0 Null Cal, C C 5 Copyright Atlas Scientific LLC

52 Export/import calibration Export: Use this command to save calibration settings Import: Use this command to load calibration settings to one or more devices. Export Import Export,? export calibration string from calibrated device* import calibration string to new device* calibration string info* 300ms processing delay *This command is only available for firmware version 2.0 and above. Export,? Wait 300ms Dec 0,20 ASCII 0 Null breakdown 0, 20 # of strings to export # of bytes to export Export strings can be up to 2 characters long Export Wait 300ms Dec 59 6F ASCII 0 Null ( of 0) (8 more) Export Wait 300ms Dec F ASCII 0 Null (0 of 0) Export Wait 300ms Dec *DONE ASCII 0 Null Import, n (FIFO) Import, 59 6F ASCII ( of 0) 52 Copyright Atlas Scientific LLC

53 Temperature scale ( C, K, F) 300ms processing delay S,c S,k S,f S,? celsius default kelvin fahrenheit temperature scale? S,c Wait 300ms Dec 0 Null S,k Wait 300ms Dec 0 Null S,f Wait 300ms Dec 0 Null S,? Wait 300ms Dec?S,f ASCII 0 Null or Dec?S,k ASCII 0 Null or Dec?S,k ASCII 0 Null -26 C,254 C (celsius) 47.5 K,527.5 K (kelvin) F 2,289.2 F (fahrenheit) 53 Copyright Atlas Scientific LLC

54 Enable/disable data logger 300ms processing delay D,n n = (n x 0 seconds) D,0 disable D,? data logger storage interval? The time period (n) is in 0 second intervals and can 300ms be any value Processing from to delay 32,000. D,6 Wait 300ms Dec 0 Null D,0 Wait 300ms Dec 0 Null D,? Wait 300ms Dec?D,6 ASCII 0 Null D,6 (after 60 seconds) Blue Green Purple I 2 C standby 54 Copyright Atlas Scientific LLC Taking reading Changing C

55 Memory recall Disable data logger to recall memory. 300ms processing delay M M,? recall sequential stored reading display memory location of last stored reading M Wait 300ms Dec,00.00 ASCII 0 Null M,? Wait 300ms Dec 4,2.00 ASCII 0 Null Copyright Atlas Scientific LLC

56 25 25 Memory clear 300ms processing delay M,clear clear all stored memory M,clear Wait 300ms Dec 0 Null M,clear Copyright Atlas Scientific LLC

57 Device information 300ms processing delay i device information i Wait 300ms Dec?i,RTD,2.0 ASCII 0 Null breakdown?i, RTD, Device 2.0 Firmware 57 Copyright Atlas Scientific LLC

58 Reading device status 300ms processing delay Status voltage at Vcc pin and reason for last restart Status Wait 300ms Dec?Status,P,5.038 ASCII 0 Null breakdown?status, P, Reason for restart Voltage at Vcc Restart codes P powered off S software reset B brown out W watchdog U unknown 58 Copyright Atlas Scientific LLC

59 Sleep mode/low power Sleep enter sleep mode/low power Send any character or command to awaken device. Sleep no response Do not read status byte after issuing sleep command. Any command wakes up device 5V STANDBY SLEEP 5.40 ma 0.4 ma 3.3V 3.80 ma 0.09 ma Sleep Standby Sleep 59 Copyright Atlas Scientific LLC

60 Protocol lock 300ms processing delay Plock, Plock,0 enable Plock disable Plock default Locks device to I 2 C mode. Plock,? Plock on/off? Plock, Wait 300ms Dec 0 Null Plock,0 Wait 300ms Dec 0 Null Plock,? Wait 300ms Dec?Plock, ASCII 0 Null Plock, Serial, 9600 Short cannot change to UART cannot change to UART 60 Copyright Atlas Scientific LLC

61 I 2 C address change 300ms processing delay I2C,n sets I 2 C address and reboots into I 2 C mode I2C,00 device reboot Warning! Changing the I 2 C address will prevent communication between the circuit and the CPU, until the CPU is updated with the new I 2 C address. n = any number 27 Default I 2 C address is 02 (0x66). I2C,00 (reboot) 6 Copyright Atlas Scientific LLC r 0.2

62 Factory reset Factory reset will not take the device out of I 2 C mode. Factory enable factory reset I 2 C address will not change Factory device reboot Clears calibration LED on codes enabled Clears data logger Factory (reboot) 62 Copyright Atlas Scientific LLC

63 Change to UART mode TX RX Baud,n switch from I 2 C to UART CPU Baud,9600 reboot in UART mode n = S Serial,9600 (reboot) Blue Green Changing to UART mode Purple Red Wh I 2 C standby Taking reading Changing I 2 C ID# Command not understood Fi 63 Copyright Atlas Scientific LLC

64 Manual switching to UART Make sure Plock is set to 0 Disconnect ground (power off) Disconnect TX and RX Connect TX to PRB Confirm RX is disconnected Connect ground (power on) Wait for LED to change from Blue to Green Disconnect ground (power off) Reconnect all data and power Connecting TX to PRB only works for the EZO RTD Temperature circuit. Short Wrong Short Disconnect RX line 64 Copyright Atlas Scientific LLC

65 EZO TM circuit footprint 7.78mm (0.7 ) 2.54mm (0. ) In your CAD software place an 8 position header. 2 Place a 3 position header at both top and bottom of the 8 position. 3 Delete the 8 position header. The two 3 position headers are now 7.78mm (0.7 ) apart from each other. 7.78mm (0.7 ) 65 Copyright Atlas Scientific LLC

66 Datasheet change log Datasheet V 2.6 Updated calibration processing delay time on pg.5 Datasheet V 2.5 Revised Plock pages to show default value. Datasheet V 2.4 Added new commands: "Find" pages 22 & 49. "Export/Import calibration" pages 26 & 52. Added new feature to continous mode "C,n" pg 23. Datasheet V 2.3 Added manual switching to UART information on pg. 59 Datasheet V 2.2 Revised Baud command information on pg 33. Datasheet V 2. Revised entire datasheet 66 Copyright Atlas Scientific LLC

67 Firmware updates V.02 Plock (March 3, 206) Added protocol lock feature Plock V.03 EEPROM (April 26, 206) Fixed glitch where EEPROM would get erased if the circuit lost power 900ms into startup V. Glitch Fix (June 9, 206) Fixed glitch where a blank name would result in garbage ouput V2.0 Update (January, 207) Replaced command response with *OK Replaced command Serial with Baud V2.02 Glitch Fix (February 6, 207) Fixed glitch where calibration would not accept floating point numbers. V2.0 (May 9, 207) Added "Find" command. Added "Export/import" command. Modified continuous mode to be able to send readings every "n" seconds. Sleep current is lowered. 67 Copyright Atlas Scientific LLC

68 Warranty Atlas Scientific Warranties the EZO class RTD circuit to be free of defect during the debugging phase of device implementation, or 30 days after receiving the EZO class RTD circuit (which ever comes first). The debugging phase The debugging phase as defined by Atlas Scientific is the time period when the EZO class RTD circuit is inserted into a bread board, or shield. If the EZO class RTD circuit is being debugged in a bread board, the bread board must be devoid of other components. If the EZO class RTD circuit is being connected to a microcontroller, the microcontroller must be running code that has been designed to drive the EZO class RTD circuit exclusively and output the EZO class RTD circuit data as a serial string. It is important for the embedded systems engineer to keep in mind that the following activities will void the EZO class RTD circuit warranty: Soldering any part of the EZO class RTD circuit. Running any code, that does not exclusively drive the EZO class RTD circuit and output its data in a serial string. Embedding the EZO class RTD circuit into a custom made device. Removing any potting compound. 68 Copyright Atlas Scientific LLC

69 Reasoning behind this warranty Because Atlas Scientific does not sell consumer electronics; once the device has been embedded into a custom made system, Atlas Scientific cannot possibly warranty the EZO class RTD circuit, against the thousands of possible variables that may cause the EZO class RTD circuit to no longer function properly. Please keep this in mind:. All Atlas Scientific devices have been designed to be embedded into a custom made system by you, the embedded systems engineer. 2. All Atlas Scientific devices have been designed to run indefinitely without failure in the field. 3. All Atlas Scientific devices can be soldered into place, however you do so at your own risk. Atlas Scientific is simply stating that once the device is being used in your application, Atlas Scientific can no longer take responsibility for the EZO class RTD circuits continued operation. This is because that would be equivalent to Atlas Scientific taking responsibility over the correct operation of your entire device. 69 Copyright Atlas Scientific LLC

EZO-CO2. Gaseous CO2. Reads. 0 10,000 ppm. Range. Factory calibrated. Calibration. 1 reading per second. Response time. 1 ppm.

EZO-CO2. Gaseous CO2. Reads. 0 10,000 ppm. Range. Factory calibrated. Calibration. 1 reading per second. Response time. 1 ppm. V 1.0 9/12/18 EZO-CO2 Embedded NDIR CO2 Sensor Reads Range Calibration time Resolution Accuracy Warmup time Cable length Data protocol Default I 2 C address Data format Operating voltage Gaseous CO2 0

More information

0.5ml to 105ml/min. Continuous dispensing Volume dispensing Constant flow rate Dose over time mode. Any 5mm O.D. tubing UART & I 2 C

0.5ml to 105ml/min. Continuous dispensing Volume dispensing Constant flow rate Dose over time mode. Any 5mm O.D. tubing UART & I 2 C V.5 Revised 4//8 EZO-PMP Embedded Dosing Pump Flow rate.5ml to 5ml/min Accuracy +/- % Modes of operation Calibration Supplied tubing Tubing size Data protocol Default I 2 C address Operating voltage Pump

More information

RTD. Temperature Circuit EZO TM. Features. PT100 / PT1000 temperature probe circuit V 1.2

RTD. Temperature Circuit EZO TM. Features. PT100 / PT1000 temperature probe circuit V 1.2 RTD PT100 / PT1000 temperature probe circuit Features Reads Extreme sensing range from -126.000 C to 1254 C Accurate temperature readings down to the thousandths place Accuracy ±(0.10 C + 0.0017* T) Automatically

More information

EZO TM class V 2.9. embedded ORP circuit This is an evolving document. ORP Circuit EZO TM. Features

EZO TM class V 2.9. embedded ORP circuit This is an evolving document. ORP Circuit EZO TM. Features class V 2.9 embedded ORP circuit This is an evolving document check back for updates. ORP Circuit Features Reads Wide range ORP readings from -1019.9mV to +1019.9mV Accurate ORP readings down to the tenths

More information

class embedded electrical conductivity circuit EZO TM Conductivity Circuit Features v1.6 This is an evolving document check back for updates.

class embedded electrical conductivity circuit EZO TM Conductivity Circuit Features v1.6 This is an evolving document check back for updates. class embedded electrical conductivity circuit Features Reads Conductivity Total dissolved solids Practical salinity units Specific gravity of sea water Conductivity Circuit v1.6 This is an evolving document

More information

EZO TM class embedded ph circuit

EZO TM class embedded ph circuit class embedded ph circuit V 2.9 This is an evolving document check back for updates. Features Reads Full range ph reading from.001 to 14.000 Accurate ph readings down to the thousandths place (+/- 0.02)

More information

EZO TM class embedded Electrical Conductivity circuit

EZO TM class embedded Electrical Conductivity circuit class embedded Electrical Conductivity circuit Features Reads Conductivity Total dissolved solids Practical salinity units Specific gravity of sea water Accuracy +/- 2% Full E.C. range from 0.07 μs/cm

More information

AtlasScientific. Micro footprint Embedded Data Logging subsystem ENV-32X. Biology Technology

AtlasScientific. Micro footprint Embedded Data Logging subsystem ENV-32X. Biology Technology Micro footprint Embedded Data Logging subsystem ENV-32X Hardware V1.6 Firmware V2.0 Features 32Mb flash memory No drivers required Specifically designed to hold strings of up to 128 characters long Read/

More information

OEM-ORP ORP. Reads mV mV. Range. 1 reading every 420ms. Response time. Any type & brand. Supported probes. Single point.

OEM-ORP ORP. Reads mV mV. Range. 1 reading every 420ms. Response time. Any type & brand. Supported probes. Single point. V 2.3 Revised /23/18 OEM-ORP Embedded ORP Circuit Reads Range Response time ORP -19.9mV 19.9mV 1 reading every 420ms Supported probes Calibration Temp compensation Data protocol Default I 2 C address Operating

More information

8:1 Serial Port Expander

8:1 Serial Port Expander 8:1 Serial Port Expander V 1.3 This is an evolving document check back for updates. Features Expand a single UART (RX / TX) serial port into 8 additional serial ports On-board LEDs indicate which channel

More information

EZO-RGB. Color. Reads. Range True 8-bit RGB format (0 255) 400ms. Response time. Narrow 15 half angle. Sensing area. Yes. Automatic color matching

EZO-RGB. Color. Reads. Range True 8-bit RGB format (0 255) 400ms. Response time. Narrow 15 half angle. Sensing area. Yes. Automatic color matching V 1.6 Revised 10/18/17 EZO-RGB Embedded Color Sensor Reads Color Range True 8-bit RGB format (0 255) Response time Sensing area 400ms Narrow 15 half angle Automatic color matching Cable length Water proof/dust

More information

MICRO-1356 MULTI-PROTOCOL READER

MICRO-1356 MULTI-PROTOCOL READER MICRO-1356 MULTI-PROTOCOL READER The Micro-1356 reader is a miniature multi-protocol RFID reader suited for embedded applications, such as handheld readers or door key card readers. The Micro-1356 has

More information

RN-174 WiFly Super Module

RN-174 WiFly Super Module RN- WiFly Super Module Features Evaluation board for the RN- module Supports chip antenna (RN--C), PCB trace antenna (RN--P), wire antenna (RN--W), and U.FL connector for an external antenna (RN--U) Ultra-low

More information

RN-171-EK Evaluation Board

RN-171-EK Evaluation Board RN -17 1-E K-DS RN-171-EK Evaluation Board Features Ultra-low power: 4-uA sleep, 40-mA Rx, 180-mA Tx at 10 dbm Configurable transmit power: 0 to +12 dbm UART hardware interfaces and SPI slave Up to 1 Mbps

More information

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner

PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION. v1.0 DRAFT Revised Dec 4, 2014 Last Revised by Alex Messner PF2100 MODBUS LOGGER CARD SYSTEM SPECIFICATION Revised Last Revised by Alex Messner This page was intentionally left blank. Table of Contents 1 Overview... 2 2 User Interface... 3 2.1 LEDs... 3 2.2 Buttons...

More information

BV4531U. I2C or Serial 6 Way Relay

BV4531U. I2C or Serial 6 Way Relay BV4533 Date February 2018 11 Feb. 2018 Firmware Revision 1.0.4 Preliminary 1.1.0 Serial Updated I2C or Serial 6 Way Relay 3 Sep. 2018 1.1.0 I2C corrections, trigger is not used Introduction This is an

More information

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags S125 Multi-Purpose 125 KHz RFID Reader 44 mm USER MANUAL MULTI PURPOSE 84 mm ONLINE & OFFLINE MODE BUILT-IN RELAY 125 KHz RFID EM4100/2 Cards & Tags 9V/24V DC Operating Voltage, AC (optional) 3 Online

More information

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

RN-174. WiFly GSX Super Module. Features. Description. Applications.   rn-174-ds v1.1 1/24/2011 www.rovingnetworks.com rn-174-ds v1.1 1/24/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna

More information

keyestudio Keyestudio MEGA 2560 R3 Board

keyestudio Keyestudio MEGA 2560 R3 Board Keyestudio MEGA 2560 R3 Board Introduction: Keyestudio Mega 2560 R3 is a microcontroller board based on the ATMEGA2560-16AU, fully compatible with ARDUINO MEGA 2560 REV3. It has 54 digital input/output

More information

IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board.

IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board. V 3.0 Revised 12/13/17 ph IXIAN Transmitter Reads ph Range.001 14.000 Accuracy Calibration Supported probes Temp probe +/ 0.002 1, 2, 3 point remotely through PLC or directly on board Any type & brand

More information

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

RN-174. WiFly GSX Super Module. Features. Description. Applications.   rn-174-ds v1.1 3/3/2011 www.rovingnetworks.com rn-174-ds v1.1 3/3/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

GP1 LCD RS232 Terminal Kit 2003 by AWC

GP1 LCD RS232 Terminal Kit 2003 by AWC GP1 LCD RS232 Terminal Kit 2003 by AWC AWC 310 Ivy Glen League City, TX 77573 (281) 334-4341 http://www.al-williams.com/awce.htm V1.2 30 Aug 2003 Table of Contents Overview...1 If You Need Help...1 Building...1

More information

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway User s Manual www.icpdas.com 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one

More information

RN-171-XV b/g Wireless LAN Module

RN-171-XV b/g Wireless LAN Module RN-171-XV 802.11 b/g Wireless LAN Module Features Drop-in Wi-Fi solution for existing systems that currently use 802.15.4 modules Based on Roving Networks robust RN-171 Wi-Fi module Based on a pseudo-standard

More information

Arduino Uno R3 INTRODUCTION

Arduino Uno R3 INTRODUCTION Arduino Uno R3 INTRODUCTION Arduino is used for building different types of electronic circuits easily using of both a physical programmable circuit board usually microcontroller and piece of code running

More information

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011 WiSnap M2 Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (RN-174-C), PCB Trace antenna (RN-174-P), wire antenna (RN- 174-W) and

More information

Color 7 click. PID: MIKROE 3062 Weight: 19 g

Color 7 click. PID: MIKROE 3062 Weight: 19 g Color 7 click PID: MIKROE 3062 Weight: 19 g Color 7 click is a very accurate color sensing Click board which features the TCS3472 color light to digital converter with IR filter, from ams. It contains

More information

MOD-RFID125 User Manual. All boards produced by Olimex are ROHS compliant. Rev.A, February 2008 Copyright(c) 2008, OLIMEX Ltd, All rights reserved

MOD-RFID125 User Manual. All boards produced by Olimex are ROHS compliant. Rev.A, February 2008 Copyright(c) 2008, OLIMEX Ltd, All rights reserved MOD-RFID125 User Manual All boards produced by Olimex are ROHS compliant Rev.A, February 2008 Copyright(c) 2008, OLIMEX Ltd, All rights reserved INTRODUCTION: FEATURES: MOD-RFID125 is an RFID station,

More information

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~  rn-134-ds v1. WiFly GSX Super Module SuRF Board Features UART interface with RS232 and TTL signaling Through hole board simplifies system integration Accepts 3-12VDC Status LEDs to show network status and data transfer

More information

I-7570 Serial To HART Converter

I-7570 Serial To HART Converter I-7570 Serial To HART Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original

More information

RADON SS SENSOR pci/l

RADON SS SENSOR pci/l 1. FEATURES Easy to use advanced technology Delivers complete set of information for instantaneous and average Radon concentrations Ideal for portable, fixed and digital applications 2. SPECIFICATION Measuring

More information

melabs Serial LCD Firmware Version 1.1 3/5/07

melabs Serial LCD Firmware Version 1.1 3/5/07 melabs Serial LCD Firmware Version 1.1 3/5/07 The melabs Serial LCD (SLCD) can display serial data from either asynchronous RS232-style or synchronous I 2 C input. A range of baud rates from 2400 to 57,600

More information

Flex Series User Guide

Flex Series User Guide User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents

More information

JMY505G User's Manual

JMY505G User's Manual JMY505G User's Manual (Revision 3.42) Jinmuyu Electronics Co. LTD 2011/6/28 Please read this manual carefully before using. If any problem, please mail to: jinmuyu@vip.sina.com Contents 1 Product introduction...

More information

GreenEye Monitor Specifications

GreenEye Monitor Specifications Number of Channels Power Monitoring Section 32 (expansion available in the future) Measurement POWER: True (or Real) Power using high speed volt and current sampling VOLTAGE: True RMS Accuracy Sampling

More information

VN310 Hardware Integration

VN310 Hardware Integration VN310 Hardware Integration Application Note 08-00041-01 Revision 1.0 December 18, 2012 www.nivis.com Contents 1. INTRODUCTION... 3 2. PIN-OUT AND INTERFACE SUMMARY... 3 3. INTERFACING WITH VN310-I FOR

More information

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]

More information

MOD-RFID125-BOX User Manual

MOD-RFID125-BOX User Manual MOD-RFID125-BOX User Manual All boards produced by Olimex are ROHS compliant Rev.B, May 2011 Copyright(c) 2011, OLIMEX Ltd, All rights reserved Page 1 INTRODUCTION: FEATURES: MOD-RFID125-BOX is an RFID

More information

USB-Based 14-Channel Data-Acquisition Module

USB-Based 14-Channel Data-Acquisition Module USB-Based 14-Channel Data-Acquisition Module DLP-IO14 LEAD FREE FEATURES: 14 IO s: 0-5V Analog, Digital In/Out, Temperature Two Bipolar Analog Inputs; ±5V Input Range Max All Analog Inputs: Up to 30Ksps

More information

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual Rev. 2.5 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors

More information

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0. ECAN-240 (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.0 Page: 1 Table of Contents Table of Contents -----------------------------------------------------------------------------2

More information

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017 DL-10 User Manual RS-485 Remote Temperature and Humidity English Ver. 1.0, Jul. 2017 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of one year from

More information

Dual Interface LCD Display Controller

Dual Interface LCD Display Controller Dual Interface LCD Display & Keypad Controller Product specification Nov 2013 V0.a ByVac Page 1 of 11 Contents 1. Introduction... 3 2. Features... 3 3. BV4618, Comparison... 3 3.1.1. BV4618... 3 3.1.2....

More information

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

RN-174. WiFly GSX Super Module. Features. Description. Applications.   rn-174-ds v1.1 4/20/2011 www.rovingnetworks.com rn-174-ds v1.1 4/20/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna

More information

Dual PT100 RTD to CAN-Bus Converter. v1.0 August 2018

Dual PT100 RTD to CAN-Bus Converter. v1.0 August 2018 Dual PT100 RTD to CAN-Bus Converter v1.0 August 2018 Product name Model number Manufacturer Dual PT100 RTD to CAN-Bus Converter CAN-PT100-DUO SK Pang Electronics Ltd 1 Contents Table of Contents 1. Introduction...

More information

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual Rev. 2.93 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

Bluetooth RS-232 Adapter

Bluetooth RS-232 Adapter BT-232B Bluetooth RS-232 Adapter with Internal Chip Antenna Bluetooth RS-232 Adapter User manual for BT-232B and BT-232B-E models BT Adapter Model BT-232B-E Bluetooth RS-232 Adapter with External Dipole

More information

BV4615. Dual Interface Zero Keypad. Product specification. Dec 2009 V0.a. ByVac Page 1 of 11

BV4615. Dual Interface Zero Keypad. Product specification. Dec 2009 V0.a. ByVac Page 1 of 11 Product specification Dec 2009 V0.a ByVac Page 1 of 11 Contents 1. Introduction...3 2. Features...3 3. Physical Specification...3 3.1. Serial connector...3 3.2. Multiple Devices...4 3.3. I2C...4 4. Output

More information

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter 1. Package content: BLE RS-232 adapter Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232D-E Package Contents: BLE RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box: 11 x 6 x 5 (cm)

More information

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual (Version 1.01) PAGE:1

More information

Features : General Description:

Features : General Description: TTL Bluetooth serial Module Class 1 (Model: BTM-T1-C) Based on the new High power Bluetooth serial modules the new low cost Bluetooth serial adapters allow for simple integration into microcontroller designs

More information

melabs Serial LCD Firmware Version 1.0 2/7/07

melabs Serial LCD Firmware Version 1.0 2/7/07 melabs Serial LCD Firmware Version 1.0 2/7/07 The melabs Serial LCD (SLCD) can display serial data from either asynchronous RS232-style or synchronous I 2 C input. A range of baud rates from 2400 to 57,600

More information

The I-7530A RS-232/485/422 to CAN Converter

The I-7530A RS-232/485/422 to CAN Converter The I-7530A RS-232/485/422 to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery

More information

CF Plug-In. Evaluation Board User Guide. Bulletin Revision Date

CF Plug-In. Evaluation Board User Guide. Bulletin Revision Date CF Plug-In Evaluation Board User Guide Bulletin Revision Date JA03-EBUG 00 06 Dec 2017 Table of Contents I. Introduction------------------------------------------------------------------------- 2 Scope

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

CoLinkEx_LPC11C14 EVB Kit User Guide

CoLinkEx_LPC11C14 EVB Kit User Guide CoLinkEx_LPC11C14 EVB Kit User Guide Rev. 1.0 Release: 2012-05-07 Website: http://www.coocox.org Forum: http://www.coocox.org/forum/forum.php?id=1 Techinal: master@coocox.com Market: market@coocox.com

More information

KNJN I2C bus development boards

KNJN I2C bus development boards KNJN I2C bus development boards 2005, 2006, 2007, 2008 KNJN LLC http://www.knjn.com/ Document last revision on December 5, 2008 R22 KNJN I2C bus development boards Page 1 Table of Contents 1 The I2C bus...4

More information

ZBXYAF Oxygen sensor control circuit board

ZBXYAF Oxygen sensor control circuit board FEATURES Control circuit board for all XYA series oxygen sensors Measuring ranges...5 or... oxygen or custom adjustable range Can be calibrated in normal air or any known O concentration Automatic or manual

More information

WIRELESS RECEIVER WRM-TS. Rev. 1.0c

WIRELESS RECEIVER WRM-TS. Rev. 1.0c WIRELESS RECEIVER WRM-TS U S E R M A N U A L Rev. 1.0c TABLE OF CONTENTS 1. General information 3 2. Technical parameters 4 3. Normal mode of operation 4 4. Command reference 5 4.1. Command get 6 4.2.

More information

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter Bluetooth V4.1 BLE RS-232 Serial Adapter 1. Package content: BLE RS-232 adapter Model: BLE-232B Package Contents: BLE RS-232 adapter x 1 Screw x2, Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 White

More information

SH1030 Rev Introduction. Ultra low power DASH7 Arduino Shield Modem. Applications. Description. 868 MHz. Features

SH1030 Rev Introduction. Ultra low power DASH7 Arduino Shield Modem. Applications. Description. 868 MHz. Features SH1030 Rev. 1.2 Applications Wireless sensor network Data acquisition equipment Security systems Industrial monitor and control Internet of things (IoT) Ultra low power DASH7 Arduino Shield Modem 868 MHz

More information

Datasheet: K-33 BLG Sensor

Datasheet: K-33 BLG Sensor Datasheet: K-33 BLG Sensor The K- 33 BLG (bio- logger) sensor is designed to measure percentage of carbon dioxide up to 30%, as well as temperature and humidity. This makes it an excellent sensor for enclosed

More information

T1K MODBUS Base Controller Specifications

T1K MODBUS Base Controller Specifications Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General

More information

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/ Rev. A 1/25/213 172 Contents Contents Temperature-Humidity Sensor Configuration Tool... 3 Read Sensor Screen... 3 Manual Calibration Screen... 4 Register View Screen... 5 Modbus Registers... 6 Reprogram

More information

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features

CAN / RS485. Product Description. Technical Reference Note. Interface Adapter. Special Features CAN / Interface Adapter For SHP Series Total Power: < 1 Watts Input Voltage: 5V Internal Outputs: CAN,, USB, I 2 C Special Features Input Protocols: 1) using Modbus 2) CAN using modified Modbus Output

More information

BV4626 General Purpose I/O. Product specification. Mar 2010 V0.a. ByVac Page 1 of 13

BV4626 General Purpose I/O. Product specification. Mar 2010 V0.a. ByVac Page 1 of 13 General Purpose I/O Product specification Mar 2010 V0.a ByVac Page 1 of 13 Contents 1. Introduction... 3 2. Features... 3 3. Physical Specification... 3 3.1. JP7... 3 3.2. Control Interface... 4 3.3. Serial

More information

eip-24/100 Embedded TCP/IP 10/100-BaseT Network Module Features Description Applications

eip-24/100 Embedded TCP/IP 10/100-BaseT Network Module Features Description Applications Embedded TCP/IP 10/100-BaseT Network Module Features 16-bit Microcontroller with Enhanced Flash program memory and static RAM data memory On board 10/100Mbps Ethernet controller, and RJ45 jack for network

More information

User Manual V1.1 Date: WiFi RS-232 Adapter. Red LED: IP Address Blue LED: TX/RX 5V Out (Pin 9)

User Manual V1.1 Date: WiFi RS-232 Adapter. Red LED: IP Address Blue LED: TX/RX 5V Out (Pin 9) 1. Package Contents: WiFi RS-232 adapter x 1 Battery power line with connector x 1 User manual x 1 USB Cable x 1 2 dbi Dipole Antenna x 1 WiFi RS-232 Adapter White box: Dimension: 10 x 5.5 x 5 (cm) Weight:

More information

ESPino - Specifications

ESPino - Specifications ESPino - Specifications Summary Microcontroller ESP8266 (32-bit RISC) WiFi 802.11 (station, access point, P2P) Operating Voltage 3.3V Input Voltage 4.4-15V Digital I/O Pins 9 Analog Input Pins 1 (10-bit

More information

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter Rev 1.3, 2018-06 Air-Farm User Manual CO2 / Temperature / Humidity Transmitter Features CO2, Temperature and Humidity measurement Three high sensitivity sensors RS485(MODBUS) Communication Analog Voltage

More information

SFP+ Breakout 2. Data Sheet. Datasheet SFP+ Breakout. 1 Overview. Table of Contents. 2 Features

SFP+ Breakout 2. Data Sheet. Datasheet SFP+ Breakout. 1 Overview. Table of Contents. 2 Features Data Sheet 2 1 Overview The is an interface board designed to connect the high speed lines of an SFP or SFP+ module to SMA connectors for test and evaluation. In addition to high speed breakout, the unit

More information

Web Site: Forums: forums.parallax.com Sales: Technical:

Web Site:  Forums: forums.parallax.com Sales: Technical: Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267

More information

WiFi to RS-232 adapter user manual

WiFi to RS-232 adapter user manual WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126

More information

BV4505. IASI-Keypad Controller. Product specification. January 2009 V0.a. ByVac Page 1 of 13

BV4505. IASI-Keypad Controller. Product specification. January 2009 V0.a. ByVac Page 1 of 13 Product specification January 2009 V0.a ByVac Page 1 of 13 Contents 1. Introduction...3 2. Features...3 3. Electrical Specification...3 3.1. Keypad Interface...3 4. Key Values Returned...3 5. Factory Reset...3

More information

How to Use an Arduino

How to Use an Arduino How to Use an Arduino By Vivian Law Introduction The first microcontroller, TMS-1802-NC, was built in 1971 by Texas Instruments. It owed its existence to the innovation and versatility of silicon and the

More information

Corning Varioptic C-C-39N0-160 Auto Focus Lens Module

Corning Varioptic C-C-39N0-160 Auto Focus Lens Module Corning Varioptic C-C-39N0-160 Auto Focus Lens Module Overview The Corning Varioptic C-C-39N0-160 auto focus lens module is an electronically controllable focus C-Mount lens based on the Corning Varioptic

More information

Figure 1. LCD & Keypad - RS232 Terminal

Figure 1. LCD & Keypad - RS232 Terminal LCD & Keypad - RS Terminal ADVANCE INFORMATION ALL INFORMATION IN THIS USER MANUAL IS PRELIMINARY AND SUBJECT TO CHANGE. LCD & Keypad - RS Terminal (R. Feb 005) 00 by DV Industrial Computer Introduction

More information

ARDUINO INDUSTRIAL 1 01 Code: A000126

ARDUINO INDUSTRIAL 1 01 Code: A000126 ARDUINO INDUSTRIAL 1 01 Code: A000126 The Industrial 101 is a small form-factor YUN designed for product integration. OVERVIEW: Arduino Industrial 101 is an Evaluation board for Arduino 101 LGA module.

More information

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06

last update December 1, 2010 reference smtirin06n page 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06 1/21 SMARTEC INFRARED INTERFACE BOARD SMTIRIN06 1. Introduction 2. Quick start and functional check Table of contents 3. Hardware inside the SMTIRIN06 system 3.1. General 3.2. Input stage 3.3. Calculation

More information

RFT(Robotous Force/Torque Sensor) Series

RFT(Robotous Force/Torque Sensor) Series RFT(Robotous Force/Torque Sensor) Series Installation and Operation Manual REVISION 1.1 1 Contents 1. Caution 4 1.1. Notices 4 1.2. Warning 4 2. Installation 5 2.1. Overview 5 2.2. Power Supply Specifications

More information

BV4501 IASI Twin Relay. Product specification. December 2008 V0.a. ByVac Page 1 of 12

BV4501 IASI Twin Relay. Product specification. December 2008 V0.a. ByVac Page 1 of 12 IASI Twin Relay Product specification December 2008 V0.a ByVac Page 1 of 12 Contents 1. Introduction...4 2. Features...4 3. Electrical Specification...4 4. Factory Reset...4 5. IASI Command set...5 5.1.

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Manual 601: : USB/RS232. Specifications. Contents. Options

Manual 601: : USB/RS232. Specifications. Contents. Options Page 1 ATE-601 601: : USB/RS232 I/O Controller - 8 Inputs, 4/8 Relays The ATE-500/600 series is a range of modular I/O controllers. It uses small standardized boards which allows you to configure the system

More information

SY021 Portable Load/Force Meter User instructions

SY021 Portable Load/Force Meter User instructions SY021 Portable Load/Force Meter User instructions Relates to firmware version 5.2 INTRODUCTION The SY021 is a portable load meter, which can indicate the load present on any attached cell. A dual channel

More information

General. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6

General. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6 General World smallest and economic solid state electrochemical CO 2 sensor has been developed for the production. It holds many patents in the structure and the materials of the sensor as well as the

More information

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14

DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14 DSTCAL Software User Manual 09/16/09 WD1037 Rev E Revised 09/09/14 Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free 800-421-2853 Phone 828-658-3131 Fax 828-658-0728 www.palmerwahl.com

More information

PACSystems* RX3i IC694ALG233

PACSystems* RX3i IC694ALG233 November 2015 PACSystems* RX3i IC694ALG233 Advanced Diagnostics Analog Current Input Module 16 Channel The PACSystems* RX3i 16-Channel Analog Current Input module provides 16 single-ended input channels.

More information

Esbus A sensor bus based on the SPI serial interface

Esbus A sensor bus based on the SPI serial interface Esbus A sensor bus based on the SPI serial interface Dr. Darold Wobschall Esensors, Inc. Amherst, NY 14226,USA Esensors Hari Sai Prasad K. Graduate Student SUNY at Buffalo Amherst, NY 14260,USA 1 Overview

More information

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2 Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2 Package content: BLE RS-232 adapter x 1 Screws for DB9 connector x 2 Nuts for DB9 connector x 2 User

More information

WM1030 Rev Introduction. Ultra low power DASH7 Modem. Applications. Description. 868 / 915 MHz. Features. WIZZILAB Technical datasheet 1/10

WM1030 Rev Introduction. Ultra low power DASH7 Modem. Applications. Description. 868 / 915 MHz. Features. WIZZILAB Technical datasheet 1/10 WM1030 Rev. 1.2 Applications Wireless sensor network Data acquisition equipment Security systems Industrial monitor and control Internet of things (IoT) Ultra low power DASH7 Modem 868 / 915 MHz 1 Introduction

More information

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1 TM HRT-710 User s Manual Version 1.23 HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of

More information

RS485 MODBUS Module 8I8RO

RS485 MODBUS Module 8I8RO Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.

More information

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973) Kanomax USA, Inc. 219 Route 206 PO Box 372 Andover, New Jersey 07821 USA (800) 247-8887 Fax: (973) 786-7586 Model 6813 THERMO-ANEMOMETER User Manual www.kanomax-usa.com Copyright 2008, Kanomax USA, Inc

More information

Owner s Hardware Service Manual Frank Control Computer System

Owner s Hardware Service Manual Frank Control Computer System Owner s Hardware Service Manual Frank Control Computer System Revision 0105 ABOUT THIS MANUAL This section describes the contents of this manual and how to use this manual effectively. It was designed

More information

ICN12. I2C to UART Bridge, ADC,DAC and I/O

ICN12. I2C to UART Bridge, ADC,DAC and I/O Firmware version 1.4 Introduction ICN12 I2C to UART Bridge, ADC,DAC and I/O This is an I2C to UART bridge, designed to give an extra UART to a microcontroller when only I2C is available. It is an I2C device

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information