1 The Host Server Oracle Solaris Configuration Guide October 2018 This guide provides configuration settings and considerations for Hosts running Oracle Solaris with SANsymphony. Basic Oracle Solaris storage administration skills are assumed including how to connect to iscsi and Fibre Channel target ports and the discovering, mounting and formatting of disk devices. The authority on real-time data

2 Table of contents Changes made to this document 3 Oracle Solaris compatibility list 4 Oracle Solaris operating system versions 4 Oracle Solaris Cluster versions 5 The DataCore Server's settings 7 Port roles 7 Multipathing ALUA support 7 7 Serving Virtual Disks 7 The Solaris Host's settings 9 Disk device settings 9 MPxIO support Solaris 11.x 10 MPxIO support Solaris 10.x 11 Known Issues 12 Appendix A 13 Preferred Server & Preferred Path settings 13 Appendix B 14 Reclaiming Storage from Disk Pools 14 Previous changes 16

3 Changes made to this document The most recent version of this document is available from here: All changes since February 2018 General This document has been reviewed for SANsymphony 10.0 PSP 8. No additional settings or configurations are required. For previous changes made to this document please see page 16 Page 3

4 Oracle Solaris compatibility list Oracle Solaris operating system versions SANsymphony 9.0 PSP 4 Update 4 (1) SANsymphony 10.0 (all versions) SOLARIS WITH ALUA WITHOUT ALUA WITH ALUA WITHOUT ALUA 9.0 or earlier Not Supported Not Supported Not Supported Not Supported 10.0 Not Supported Not Qualified Not Supported Qualified 11.0 Not Supported Qualified Not Supported Not Qualified 11.1 Not Supported Qualified Not Supported Qualified 11.2 Not Supported Not Qualified Not Supported Qualified 11.3 Not Supported Not Supported Not Qualified [2] Qualified Notes: Qualified vs. Not Qualified vs. Not Supported See page 6 for definitions. DataCore Server Front-End Port connections Fibre Channel connections are supported. ISCSI connections are not supported. With Oracle Solaris Cluster See next page for the Oracle Solaris Cluster versions that can be used. SCSI UNMAP There is no support for SCSI UNMAP from Solaris hosts. 1 Earlier versions are End of Life. See: 2 A fix by Oracle for Solaris 11.3 was added in Package Update 3 (11.3.3) that allows ALUA on Solaris to work with DataCore Servers. Users who wish to 'Self Qualify' with ALUA can do so, but must be on at least Oracle Solaris to run the self-qualification tests. Page 4

5 Solaris compatibility lists Oracle Solaris Cluster versions Oracle Solaris Operating System Version CLUSTER 9.x AND EARLIER 10.x 11.x 2.x Not Supported Not Supported Not Supported 3.x Not Supported Supported Not Supported 4.x Not Supported Not Supported Supported Notes: See the previous page for Oracle Solaris / SANsymphony combinations that are qualified. Page 5

6 Solaris compatibility lists Qualified vs. Not Qualified vs. Not Supported Qualified This combination has been tested by DataCore and all the host-specific settings listed in this document applied using non-mirrored, mirrored and Dual Virtual Disks. Not Qualified This combination has not yet been tested by DataCore using Mirrored or Dual Virtual Disks types. DataCore cannot guarantee 'high availability' (failover/failback, continued access etc.) even if the host-specific settings listed in this document are applied. Self-qualification may be possible please see Technical Support FAQ #1506 Mirrored or Dual Virtual Disks types are configured at the users own risk; however, any problems that are encountered while using AIX versions that are 'Not Qualified' will still get root-cause analysis. Non-mirrored Virtual Disks are always considered 'Qualified' - even for 'Not Qualified' combinations of AIX/SANsymphony. Not Supported This combination has either failed 'high availability' testing by DataCore using Mirrored or Dual Virtual Disks types; or the operating System's own requirements/limitations (e.g. age, specific hardware requirements) make it impractical to test. DataCore will not guarantee 'high availability' (failover/failback, continued access etc.) if the host-specific settings listed in this document are applied. Mirrored or Dual Virtual Disks types are configured at the users own risk. Self-qualification is not possible. Mirrored or Dual Virtual Disks types are configured at the users own risk; however, any problems that are encountered while using AIX versions that are 'Not Supported' will get best-effort Technical Support (e.g. to get access to Virtual Disks) but no root-cause analysis will be done. Non-mirrored Virtual Disks are always considered 'Qualified' even for 'Not Supported' combinations of AIX/SANsymphony. AIX versions that are End of Service Self-qualification may be possible for versions that are considered Not Qualified by DataCore but only if there is an agreed support contract with IBM. Please contact DataCore Technical Support before attempting any self-qualification of For any problems that are encountered while using AIX versions that are EOS with DataCore Software, only best-effort Technical Support will be performed (e.g. to get access to Virtual Disks). Root-cause analysis will not be done. Non-mirrored Virtual Disks are always considered 'Qualified'. Page 6

7 The DataCore Server's settings Operating System Type See the Registering Hosts section from the SANsymphony Help: When registering the Host for the first time, choose the 'Oracle (SUN) Solaris' menu option. Port roles Ports used for serving Virtual Disks to Hosts should only have the Front End (FE) role enabled. Mixing other Port Role types may cause unexpected results as Ports that only have the FE role enabled will be turned off when the DataCore Server software is stopped (even if the physical server remains running). This helps to guarantee that any Hosts do not still try to access FE Ports, for any reason, once the DataCore Software is stopped but where the DataCore Server remains running. Any Port with the Mirror and/or Back End role enabled do not shut off when the DataCore Server software is stopped but still remain active. Multipathing The Multipathing Support option should be enabled so that Mirrored Virtual Disks or Dual Virtual Disks can be served to Hosts from all available DataCore FE ports. Also see the Multipathing Support section from the SANsymphony Help: WebHelp/Hosts.htm Non-mirrored Virtual Disks and Multipathing Non-mirrored Virtual Disks can still be served to multiple Hosts and/or multiple Host Ports from one or more DataCore Server FE Ports if required; in this case the Host can use its own multipathing software to manage the multiple Host paths to the Single Virtual Disk as if it was a Mirrored or Dual Virtual Disk. ALUA support Please refer to the Solaris Compatibility List on page 4. Serving Virtual Disks For the first time DataCore recommends that before serving Virtual Disks for the first time to a Host, that all DataCore Front-End ports on all DataCore Servers are correctly discovered by the Host first. Then, from within the SANsymphony Console, the Virtual Disk is marked Online, up to date and that the storage sources have a host access status of Read/Write. To more than one Host port DataCore Virtual Disks always have their own unique Network Address Authority (NAA) identifier that a Host can use to manage the same Virtual Disk being served to multiple Ports on the same Host Server and the same Virtual Disk being served to multiple Hosts. Page 7

8 The DataCore Server's settings While DataCore cannot guarantee that a disk device's NAA is used by a Host's operating system to identify a disk device served to it over different paths generally we have found that it is. And while there is sometimes a convention that all paths by the same disk device should always using the same LUN 'number' to guarantees consistency for device identification, this may not be technically true. Always refer to the Host Operating System vendor s own documentation for advice on this. DataCore's Software does, however always try to create mappings between the Host's ports and the DataCore Server's Front-end (FE) ports for a Virtual Disk using the same LUN number where it can. The software will first find the next available (lowest) LUN 'number' for the Host- DataCore FE mapping combination being applied and will then try to apply that same LUN number for all other mappings that are being attempted when the Virtual Disk is being served. If any Host-DataCore FE port combination being requested at that moment is already using that same LUN number (e.g. if a Host has other Virtual Disks served to it from previous) then the software will find the next available LUN number and apply that to those specific Host-DataCore FE mappings only. Also See Registering Hosts Changing Virtual Disk Settings - SCSI Standard Inquiry Page 8

9 The Solaris Host's settings Disk device settings Disk IO timeout /kernel/system Add the following line to set the Disk IO Timeout to 60 seconds. set sd:sd_io_time = 0x3c Disk retry settings /kernel/drv/sd.conf or /kernel/drv/ssd.conf Depending on your architecture edit either /kernel/drv/sd.conf or /kernel/drv/ssd.conf and add the following entries: sd-config-list = "DataCoreVirtual Disk", "retries-busy:60"; sd-config-list = "DataCoreSANsymphony", "retries-busy:60"; sd-config-list = "DataCoreSANmelody", "retries-busy:60"; Notes A reboot of the Solaris server will be needed for the setting to take effect. If the sd_io_time entry already exists, make sure the value is set as above. The value must be entered as a hexadecimal value. The lines for "DataCoreSANsymphony" and "DataCoreSANmelody" disk devices may only necessary if the Virtual Disk served to the Solaris Host was created using DataCore's SANmelody or SANsymphony 7.x and earlier software versions. Page 9

10 The Solaris Host's settings MPxIO support Solaris 11.x /etc/driver/drv/scsi_vhci.conf Add the following entries: scsi-vhci-failover-override = "DataCoreVirtual Disk", "f_sym"; scsi-vhci-failover-override = "DataCoreSANsymphony", "f_sym"; scsi-vhci-failover-override = "DataCoreSANmelody", "f_sym"; In the Load balancing global configuration section set the following entry: load-balance="none"; Notes The lines for "DataCoreSANsymphony" and "DataCoreSANmelody" disk devices may only be necessary if the Virtual Disk served to the Solaris Host was created using DataCore's SANmelody or SANsymphony 7.x and earlier software versions. 'stmsboot e' and 'stmsboot u' commands will be needed to enable multipathing (if not previously run) and the vfstab will need to be updated as well. In either case a reboot will be needed. Refer to Oracle for advice. Also See Managing SAN Devices and Multipathing in Oracle Solaris 11.3 Configuring Oracle Solaris I/O Multipathing Features 'Configuring Third-Party Storage Devices' 'Configuring Load Balancing Policy for Oracle Solaris I/O Multipathing' Oracle s Solaris Administration Guide How to Customize a Driver Configuration System Administration Commands stmsboot Changing Virtual Disk Settings - SCSI Standard Inquiry Page 10

11 The Solaris Host's settings MPxIO support Solaris 10.x /etc/driver/drv/scsi_vhci.conf Add the following entries: device-type-scsi-options-list = "DataCoreVirtual Disk", "symmetric-option"; "DataCoreSANsymphony", "symmetric-option"; "DataCoreSANmelody", "symmetric-option"; symmetric-option=0x ; In the Load balancing global configuration section set the following entry: load-balance="none"; Notes The lines for "DataCoreSANsymphony" and "DataCoreSANmelody" disk devices may only be necessary if the Virtual Disk served to the Solaris Host was created using DataCore's SANmelody or SANsymphony 7.x and earlier software versions. 'stmsboot e' and 'stmsboot u' commands will be needed to enable multipathing (if not previously run) and the vfstab will need to be updated as well. In either case a reboot will be needed. Refer to Oracle for advice. Also See Managing SAN Devices and Multipathing in Oracle Solaris 11.3 Configuring Oracle Solaris I/O Multipathing Features 'Configuring Third-Party Storage Devices' 'Configuring Load Balancing Policy for Oracle Solaris I/O Multipathing' Oracle s Solaris Administration Guide How to Customize a Driver Configuration System Administration Commands stmsboot Changing Virtual Disk Settings - SCSI Standard Inquiry Page 11

12 Known Issues The following is intended to make DataCore Software users aware of any issues that affect performance, access or may give unexpected results under particular conditions when SANsymphony is used in configurations with Oracle Solaris Hosts. These Known Issues may have been found during DataCore s own testing but others may have been reported by our users when a solution was found that was not to do with DataCore s own products. DataCore cannot be held responsible for incorrect information regarding another vendor s products and no assumptions should be made that DataCore has any communication with these other vendors regarding the issues listed here. We always recommend that the vendor s should be contacted directly for more information on anything listed in this section. For Known issues that apply to DataCore Software s own products, please refer to the relevant DataCore Software Component s release notes. Two or more Disk Devices are listed for the same DataCore Virtual Disk Check for mistakes in the scsi_vhci.conf file see page 9, Make sure that multipathing has been enabled via the 'stmsboot e' command Make sure that the Host has been rebooted after using the 'stmsboot u' command. All paths to DataCore Virtual Disk are considered primary There is no simple way to determine an Oracle Solaris Host s current active path (for example using the 'luxadm' command) so use either Oracle Solaris own system messages - which may indicate the current path being used and/or SANsymphony s Live Performance UI to see IO being sent to/from Host Ports. Also see: Live Performance Page 12

13 Appendix A Preferred Server & Preferred Path settings Without ALUA enabled If Hosts are registered without ALUA support, the Preferred Server and Preferred Path settings will serve no function. All DataCore Servers and their respective Front End (FE) paths are considered equal. It is up to the Host s own Operating System or Failover Software to determine which DataCore Server is its preferred server. With ALUA enabled ALUA is not supported for Oracle Solaris Hosts. Also see Preferred Servers and Preferred Paths from: Page 13

14 Appendix B Reclaiming Storage from Disk Pools How much storage will be reclaimed? This is impossible to predict. SANsymphony can only reclaim Storage Allocation Units that have no block-level data on them. If a Host write its data all over its own filesystem, rather than contiguously, the amount of storage that can be reclaimed may be significantly less than expected. Defragmenting data on Virtual Disks It may be possible to use a Host s own defragmentation tools to consolidate data spread out all over the host s filesystem but care should be taken as even more storage may be allocated while the existing data is defragmented. Once any defragmentation is completed then additional steps will need to wipe the free filesystem space on the host and then use SANsymphony s Manual Reclamation. Notes on SANsymphony's Reclamation feature Automatic Reclamation SANsymphony checks for any zero write I/O as it is received by the Disk Pool and keeps track of which block addresses they were sent to. When all the blocks of an allocated SAU have received zero write I/O, the storage used by the SAU is then reclaimed. Mirrored and replicated Virtual Disks will mirror/replicate the zero write I/O so that storage can be reclaimed on the mirror/replication destination DataCore Server in the same way. Manual Reclamation SANsymphony checks for zero block data by sending read I/O to the storage. When all the blocks of an allocated SAU are detected as having zero data on them, the storage used by the SAU is then reclaimed. Mirrored Virtual Disks will receive the manual reclamation request on all DataCore Servers involved in the mirror configuration at the same time and each DataCore Server will read from its own storage. The Manual reclamation request is not sent to replication destination DataCore Servers from the source. Replication destinations will need to be manually reclaimed separately. Page 14

15 Appendix B Reclaiming storage from Disk Pools Reclaiming storage on the Host manually A suggestion would be to create a sparse file of an appropriate size and write zeroes it using the dd command. Here is an example with a 2TB sparse file: dd if=/dev/zero of=my_sparse_file bs=1024 count= Also see Auto-reclamation of unused SAUs Reclaiming Unused Virtual Disk Space in Disk Pools: Page 15

16 Previous changes General This document has been reviewed for SANsymphony 10.0 PSP 7. No additional settings or configurations are required. February 2018 Removed Appendix B Configuring Disk Pools The information here has been removed as it is now superseded by the information in: The DataCore Server- Best Practice Guidelines What was previously 'Appendix C' has now been moved to 'Appendix B'. List of qualified Oracle Solaris Versions Solaris 11.3 is now qualified with SANsymphony-V 10.x without ALUA. October 2017 This document has been reviewed for SANsymphony 10.0 PSP 6 (including all updates). No additional technical information was required. May 2017 Appendix C - Reclaiming storage Automatic and Manual reclamation These two sections have been re-written with more detailed explanations and technical notes. November 2016 This document has been reviewed for SANsymphony 10.0 PSP 5. No updates were required. July 2016 Host Settings - Configuring MPxIO support for DataCore Virtual Disks March 2016 Oracle Solaris 10.x Two more lines have been added for the 'scsi_vhci.conf 'file. Previously the required setting was documented as this: device-type-scsi-options-list = "DataCoreVirtual Disk", "symmetric-option"; symmetric-option=0x ; The setting is now documented as: device-type-scsi-options-list = "DataCoreVirtual Disk", "symmetric-option"; "DataCoreSANsymphony", "symmetric-option"; "DataCoreSANmelody", "symmetric-option"; symmetric-option=0x ; Oracle Solaris 11.x Two more lines have been added for the scsi-vhci-failover-override file. Previously the required setting was documented as this: scsi-vhci-failover-override = "DataCoreVirtual Disk", "f_sym"; Page 16

17 Previous changes The setting is now documented as: scsi-vhci-failover-override = "DataCoreVirtual Disk", "f_sym"; scsi-vhci-failover-override = "DataCoreSANsymphony", "f_sym"; scsi-vhci-failover-override = "DataCoreSANmelody", "f_sym"; Existing users that have never had to upgrade from either SANsymphony 7 or SANmelody 3 can ignore adding these additional lines. Use Solaris's 'format' command and then the 'inquiry' option from the menu to obtain the DataCore Virtual Disk's SCSI Information (including the Vital Product Data (VPD) that will determine if you need to add these additional lines or not). Added List of qualified Oracle Solaris Versions Added Oracle Solaris version February 2016 SANsymphony-V 8.x and all versions of SANsymphony 9.x before PSP4 Update 4 are now End of Life. Please see: End of Life Notifications April 2015 Added List of qualified Oracle Solaris Versions - Notes on qualification This section has been updated and new information added regarding the definitions of all qualified, unqualified and not supported labels. A new section on Oracle Solaris versions that are no longer in development has also been added at the end of this section. Added Host Settings All Versions of Oracle Solaris SCSI Disk Setting A new entry in the sd.conf/ssd.conf file (depending on your architecture) is required: sd-config-list ="DataCoreVirtual Disk", "retries-busy:60"; March 2015 Host Settings Configuring MPxIO support for DataCore Virtual Disks Oracle Solaris 10.x and 11.x An edit in the scsi_vhci.conf file is required in the Load balancing global configuration section: load-balance="none"; February 2015 List of qualified Oracle Solaris Versions Solaris 10.x is now qualified with SANsymphony-V 10.x (also with Oracle Solaris Cluster 3.x) using non-alua settings. Note: iscsi is still not considered qualified at this time; all qualified versions are with Fibre Channel only. Page 17

18 Previous changes 2014 and earlier December 2014 List of qualified Oracle Solaris Versions Footnotes have been added with additional information about supported Oracle Solaris Cluster configurations with the different versions of the base operating system. November 2014 List of qualified Solaris Versions the table include Solaris Not Supported has now been changed to mean explicitly Not Supported for Mirrored or Dual Virtual Disks. Single Virtual Disks are now always considered supported. Host Settings Oracle Solaris 10.x - Configuring MPxIO support for DataCore Virtual Disks The required edit for the scsi_vhci.conf file was not clear enough. It previously said to edit the "defaults" section. This was not accurate enough and so the description and example has been updated to say to edit the "device-type-scsioptions-list" section. Oracle Solaris 11.x - Configuring MPxIO support for DataCore Virtual Disks The required edit for the scsi_vhci.conf file was not clear enough. It previously said to edit the "defaults" section. This was not accurate enough and so the description and example has been updated to say to edit the "scsi-vhci-failoveroverride" section. Added an additional Note to run the stmsboot e command to enable Multipathing (including a reference to Oracle s own SAN Configuration and Multipathing Guide) August 2014 This document combines all of DataCore s Oracle Solaris-related information from older Technical Bulletins into a single document including: Technical Bulletin 3: "Oracle/SUN Hosts with StorEdge SAN Foundation Software with Traffic Manager" Technical Bulletin 8: "Formatting Host s File Systems on Virtual Disks created from Disk Pools" Technical Bulletin 11: "Disk Timeout Settings on Hosts" Technical Bulletin 16: "Reclaiming Space in Disk Pools" Added Which Distributions are qualified? Added new tables to show which versions are explicitly qualified, unqualified and not supported with either SANsymphony-V 8.x or 9.x, and if the configuration is with or without ALUA enabled Hosts. Note that the minimum requirement for SANsymphony-V 8.x is now 8.1 PSP1 Update 4 to guarantee expected behavior for qualified versions of Oracle Solaris Oracle Solaris 11 has now been added. Appendix A This section gives more detail on the Preferred Server and Preferred Path settings with regard to how it may affect a Host. Appendix B This section incorporates information regarding "Reclaiming Space in Disk Pools" (from Technical Bulletin 16) that is specific to Oracle Solaris Hosts. Host Settings - Improved explanations to most of the required Host Settings and DataCore Server Settings generally. Technical Bulletin 3: "Oracle/SUN Hosts with StorEdge SAN Foundation Software with Traffic Manager" July 2013 Removed all references to SANmelody as this product is now end of life. How to determine the Active IO Path in the troubleshooting section. July 2012 Update steps to allow for the product ID to be used Page 18

19 Previous changes July 2012 Added SANsymphony-V 9.x. No additional Appserver/Host changes required. April 2012 DataCore Server and Host minimum requirements. Removed all references to End of Life SANsymphony and SANmelody versions that are no longer supported as of December copyright. DataCore Server and Host minimum requirements. DataCore Server and Host configuration settings. January 2011 Added note for load-balance=none. June 2010 Not supported for iscsi Failover. Added Oracle Solaris 10. July 2007 Initial publication of Technical Bulletin. Tested on Solaris 9 and STMS version Page 19

20 The authority on real-time data Copyright 2018 by DataCore Software Corporation. All rights reserved. DataCore, the DataCore logo and SANsymphony are trademarks of DataCore Software Corporation. Other DataCore product or service names or logos referenced herein are trademarks of DataCore Software Corporation. All other products, services and company names mentioned herein may be trademarks of their respective owners. ALTHOUGH THE MATERIAL PRESENTED IN THIS DOCUMENT IS BELIEVED TO BE ACCURATE, IT IS PROVIDED AS IS AND USERS MUST TAKE ALL RESPONSIBILITY FOR THE USE OR APPLICATION OF THE PRODUCTS DESCRIBED AND THE INFORMATION CONTAINED IN THIS DOCUMENT. NEITHER DATACORE NOR ITS SUPPLIERS MAKE ANY EXPRESS OR IMPLIED REPRESENTATION, WARRANTY OR ENDORSEMENT REGARDING, AND SHALL HAVE NO LIABILITY FOR, THE USE OR APPLICATION OF ANY DATACORE OR THIRD PARTY PRODUCTS OR THE OTHER INFORMATION REFERRED TO IN THIS DOCUMENT. ALL SUCH WARRANTIES (INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT, FITNESS FOR A PARTICULAR PURPOSE AND AGAINST HIDDEN DEFECTS) AND LIABILITY ARE HEREBY DISCLAIMED TO THE FULLEST EXTENT PERMITTED BY LAW. No part of this document may be copied, reproduced, translated or reduced to any electronic medium or machinereadable form without the prior written consent of DataCore Software Corporation

This guide provides configuration settings and considerations for SANsymphony Hosts running Oracle's Solaris.

This guide provides configuration settings and considerations for SANsymphony Hosts running Oracle's Solaris. The Host Server Oracle Solaris Configuration Guide October 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running Oracle's Solaris. Basic Solaris administration

More information

The Host Server. HPUX Configuration Guide. August The authority on real-time data

The Host Server. HPUX Configuration Guide. August The authority on real-time data The Host Server HPUX Configuration Guide August 2018 This guide provides configuration settings and considerations for Hosts running HPUX with SANsymphony. Basic HPUX storage administration skills are

More information

The Host Server. AIX Configuration Guide. August The Data Infrastructure Software Company

The Host Server. AIX Configuration Guide. August The Data Infrastructure Software Company The Host Server AIX Configuration Guide August 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running IBM's AIX. Basic AIX administration skills are assumed including

More information

The Host Server. HPUX Configuration Guide. May The Data Infrastructure Software Company

The Host Server. HPUX Configuration Guide. May The Data Infrastructure Software Company The Host Server HPUX Configuration Guide May 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running HPUX. Basic HPUX administration skills are assumed including

More information

The Host Server. Citrix XenServer Configuration Guide. May The authority on real-time data

The Host Server. Citrix XenServer Configuration Guide. May The authority on real-time data The Host Server Citrix XenServer Configuration Guide May 2018 This guide provides configuration settings and considerations for Hosts running XenServer with SANsymphony. Basic XenServer storage administration

More information

The Host Server. Linux Configuration Guide. August The authority on real-time data

The Host Server. Linux Configuration Guide. August The authority on real-time data The Host Server Linux Configuration Guide August 2018 This guide provides configuration settings and considerations for Hosts running Linux with SANsymphony. Basic Linux storage administration skills are

More information

The Host Server. Citrix XenServer Configuration Guide. November The Data Infrastructure Software Company

The Host Server. Citrix XenServer Configuration Guide. November The Data Infrastructure Software Company The Host Server Citrix XenServer Configuration Guide November 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running Citrix XenServer. Basic Citrix XenServer administration

More information

The Host Server. Microsoft Windows Configuration Guide. February The Data Infrastructure Software Company

The Host Server. Microsoft Windows Configuration Guide. February The Data Infrastructure Software Company The Host Server Microsoft Windows Configuration Guide February 2018 This guide provides configuration settings and considerations for SANsymphony Hosts running Microsoft Windows. Basic Microsoft Windows

More information

The Host Server. Microsoft Windows Configuration Guide. September The Data Infrastructure Software Company

The Host Server. Microsoft Windows Configuration Guide. September The Data Infrastructure Software Company The Host Server Microsoft Windows Configuration Guide September 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running Microsoft Windows. Basic Microsoft Windows

More information

The Host Server. Linux Configuration Guide. October 2017

The Host Server. Linux Configuration Guide. October 2017 The Host Server Linux Configuration Guide October 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running Linux. Basic Linux administration skills are assumed including

More information

The DataCore and Host servers

The DataCore and Host servers The DataCore and Host servers Qualified Hardware Components February 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. In general

More information

The DataCore and Host servers

The DataCore and Host servers The DataCore and Host servers Qualified Hardware Components May 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. In general DataCore

More information

Qualified Hardware Components

Qualified Hardware Components For DataCore and Host Servers October 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. The authority on real-time data Changes

More information

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi.

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. The Host Server VMware ESXi Configuration Guide February 2018 This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. Basic VMware administration skills

More information

Qualified Hardware Components

Qualified Hardware Components DataCore and Host Servers November 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. Also see Minimum Hardware Requirements https://www.datacore.com/products/software-defined-storage/tech/prerequisites/

More information

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi.

This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. The Host Server VMware ESXi Configuration Guide October 2017 This guide provides configuration settings and considerations for SANsymphony Hosts running VMware ESX/ESXi. Basic VMware administration skills

More information

This guide provides configuration settings and considerations for Hosts running VMware ESXi.

This guide provides configuration settings and considerations for Hosts running VMware ESXi. The Host Server VMware ESXi Configuration Guide May 2018 This guide provides configuration settings and considerations for Hosts running VMware ESXi. Basic VMware storage administration skills are assumed

More information

SANmelody TRIAL Quick Start Guide

SANmelody TRIAL Quick Start Guide Page 1 SANmelody TRIAL Quick Start Guide From Installation to Presenting Virtual Storage Download the trial software at: SANmelody Trial Software SANmelody TRIAL Quick Start Guide Change Summary August,

More information

Shared Multi Port Array (SMPA)

Shared Multi Port Array (SMPA) Shared Multi Port Array (SMPA) Tested Configurations October 2018 This document lists all storage arrays that have been tested using DataCore s own SMPA validation tests. Entries that are marked as passed

More information

Shared Multi Port Array (SMPA)

Shared Multi Port Array (SMPA) Shared Multi Port Array (SMPA) Tested Configurations July 2018 This document lists all storage arrays that have been tested using DataCore s own SMPA validation tests. Entries that are marked as passed

More information

Lenovo Storage DX8200D System Installation Guide (Additional Appliances in Existing Server Group)

Lenovo Storage DX8200D System Installation Guide (Additional Appliances in Existing Server Group) Lenovo Storage DX8200D System Installation Guide (Additional Appliances in Existing Server Group) First Edition (December 2016) Copyright Lenovo 2016. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software

More information

Quick Start Guide: Creating HA Device with StarWind Virtual SAN

Quick Start Guide: Creating HA Device with StarWind Virtual SAN One Stop Virtualization Shop Quick Start Guide: August 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

USING ISCSI MULTIPATHING IN THE SOLARIS 10 OPERATING SYSTEM

USING ISCSI MULTIPATHING IN THE SOLARIS 10 OPERATING SYSTEM USING ISCSI MULTIPATHING IN THE SOLARIS 10 OPERATING SYSTEM Aaron Dailey, Storage Network Engineering Scott Tracy, Storage Network Engineering Sun BluePrints OnLine December 2005 Part No 819-3730-10 Revision

More information

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.0 This paper describes how to implement a Fibre Channel (FC) SAN

More information

Brocade Fabric OS DATA CENTER. Target Path Selection Guide October 17, 2017

Brocade Fabric OS DATA CENTER. Target Path Selection Guide October 17, 2017 October 17, 2017 DATA CENTER Brocade Fabric OS Target Path Selection Guide Brocade Fabric OS (Brocade FOS) Target Path releases are recommended code levels for Brocade Fibre Channel switch platforms. Use

More information

OSIG Change History Article

OSIG Change History Article OSIG Change History Article Change history The OSIG has moved The OSIG is now available as a web application. See http://lenovopress.com/osig 21 September 2016 Windows Server 2016 is Certified on x3850

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CD-TE Third edition: August 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CE-TE Third edition: December 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P.

More information

Veritas Storage Foundation in a VMware ESX Environment

Veritas Storage Foundation in a VMware ESX Environment Veritas Storage Foundation in a VMware ESX Environment Linux and Solaris x64 platforms January 2011 TABLE OF CONTENTS Introduction... 3 Executive Summary... 4 Overview... 5 Virtual Machine File System...

More information

Veritas Storage Foundation In a VMware ESX Environment

Veritas Storage Foundation In a VMware ESX Environment Veritas Storage Foundation In a VMware ESX Environment Linux and Solaris x64 platforms December 2008 TABLE OF CONTENTS Introduction... 3 Executive Summary... 4 Overview... 5 Virtual Machine File System...

More information

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V MAY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

IBM XIV Provider for Microsoft Windows Volume Shadow Copy Service Version Release Notes

IBM XIV Provider for Microsoft Windows Volume Shadow Copy Service Version Release Notes IBM XIV Provider for Microsoft Windows Volume Shadow Copy Service Version 2.4.0 Release Notes Second Edition (July 2013) This edition applies to version 2.4.0 of the IBM XIV Provider for Microsoft Windows

More information

HP StorageWorks Continuous Access EVA 2.1 release notes update

HP StorageWorks Continuous Access EVA 2.1 release notes update HP StorageWorks Continuous Access EVA 2.1 release notes update Part number: T3687-96038 Third edition: August 2005 Legal and notice information Copyright 2005 Hewlett-Packard Development Company, L.P.

More information

Oracle VM. Getting Started Guide for Release 3.2

Oracle VM. Getting Started Guide for Release 3.2 Oracle VM Getting Started Guide for Release 3.2 E35331-04 March 2014 Oracle VM: Getting Started Guide for Release 3.2 Copyright 2011, 2014, Oracle and/or its affiliates. All rights reserved. Oracle and

More information

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V.

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. MARCH 2015 TECHNICAL PAPER Trademarks StarWind,

More information

The DataCore Server. Best Practice Guidelines. February The Data Infrastructure Software Company

The DataCore Server. Best Practice Guidelines. February The Data Infrastructure Software Company The DataCore Server February 2018 The Data Infrastructure Software Company Table of contents Changes made to this document 3 Design objectives 5 The server hardware 7 BIOS 7 CPUs 8 Power 9 System memory

More information

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN of HyperConverged 2 Nodes with Hyper-V Cluster AUGUST 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and

More information

IBM Systems. IBM Virtual Machine Manager Release Notes

IBM Systems. IBM Virtual Machine Manager Release Notes IBM Systems IBM Virtual Machine Manager 2.0.1 Release Notes IBM Systems IBM Virtual Machine Manager 2.0.1 Release Notes Note Before using this information and the product it supports, read the general

More information

May 2014 Product Shipping Configuration Change Notice

May 2014 Product Shipping Configuration Change Notice May 2014 Product Shipping Configuration Change Notice Engineering Advisory 92278 This engineering advisory provides details about shipping configuration changes planned for May 2014 to Polycom Unified

More information

Optimus.2 Ascend. Rev A August, 2014 RELEASE NOTES.

Optimus.2 Ascend. Rev A August, 2014 RELEASE NOTES. RELEASE NOTES Rev A August, 2014 Optimus.2 Ascend 951 SanDisk Drive, Milpitas, CA 95035 2014 SanDIsk Corporation. All rights reserved www.sandisk.com ESD Caution Handling Static electricity may be discharged

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

An Oracle White Paper June StorageTek In-Drive Reclaim Accelerator for the StorageTek T10000B Tape Drive and StorageTek Virtual Storage Manager

An Oracle White Paper June StorageTek In-Drive Reclaim Accelerator for the StorageTek T10000B Tape Drive and StorageTek Virtual Storage Manager An Oracle White Paper June 2011 StorageTek In-rive Reclaim Accelerator for the StorageTek T10000B Tape rive and StorageTek Virtual Storage Manager Introduction 1 The Tape Storage Space Problem 3 The StorageTek

More information

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN White Paper VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN Benefits of EMC VNX for Block Integration with VMware VAAI EMC SOLUTIONS GROUP Abstract This white paper highlights the

More information

The DataCore Server. Best Practice Guidelines. August The Data Infrastructure Software Company

The DataCore Server. Best Practice Guidelines. August The Data Infrastructure Software Company The DataCore Server August 2017 The Data Infrastructure Software Company Table of contents Changes made to this document 4 Overview 5 Which versions of SANsymphony does this apply to? 6 High level design

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

Stonebranch Solutions

Stonebranch Solutions Stonebranch Solutions Version 4.3.0 Stonebranch Solutions Installation Guide sb-install-4301 Stonebranch Solutions Installation Guide Stonebranch Solutions 4.3.0 Document Name Document ID Stonebranch

More information

Release Notes and User Guide: DataCore SANsymphony Storage Replication Adapter 1.1

Release Notes and User Guide: DataCore SANsymphony Storage Replication Adapter 1.1 Release Notes Cumulative Change Summary Date Original 1.0 release July 11, 2012 Added references to SANsymphony Help Topics, FAQs and other documents; Removed sections to create SRA User Guide August 17,

More information

VMware VMFS Volume Management VMware Infrastructure 3

VMware VMFS Volume Management VMware Infrastructure 3 Information Guide VMware VMFS Volume Management VMware Infrastructure 3 The VMware Virtual Machine File System (VMFS) is a powerful automated file system that simplifies storage management for virtual

More information

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 DECEMBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software

More information

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Dell EMC Engineering February 2018 A Dell EMC Technical White Paper Revisions Date August 2017

More information

CA Unified Infrastructure Management

CA Unified Infrastructure Management CA Unified Infrastructure Management clariion Release Notes All series Copyright Notice This online help system (the "System") is for your informational purposes only and is subject to change or withdrawal

More information

NetApp AltaVault Cloud-Integrated Storage Appliances

NetApp AltaVault Cloud-Integrated Storage Appliances Technical Report NetApp AltaVault Cloud-Integrated Storage Appliances Solution Deployment: AltaVault Christopher Wong, NetApp November 2017 TR-4422 Abstract This solution deployment guide outlines how

More information

HP StorageWorks Enterprise Virtual Array

HP StorageWorks Enterprise Virtual Array Release Notes HP StorageWorks Enterprise Virtual Array Product Version: v3.025 First Edition March, 2005 Part Number: 5697 5237 *5697-5237* This document contains the most recent product information about

More information

Creating Resources on the ZFS Storage Appliance

Creating Resources on the ZFS Storage Appliance Oracle Enterprise Manager Ops Center Creating Non-Global Zones Using a SAN Storage Library 12c Release 3 (12.3.0.0.0) E65613-01 October 2015 This guide provides an end-to-end example for how to use Oracle

More information

IBM XIV Host Attachment Kit for HP-UX Version Release Notes

IBM XIV Host Attachment Kit for HP-UX Version Release Notes IBM XIV Host Attachment Kit for HP-UX Version 1.8.0 Release Notes First Edition (May 2012) This document edition applies to version 1.8.0 of the IBM XIV Host Attachment Kit for HP-UX software package.

More information

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX Fujitsu ETERNUS Storage Center Storage Supported ETERNUS DX100 S3, DX200 S3, DX200F, DX500 S3, DX600 S3, ETERNUS AF250, ETERNUS AF650, ETERNUS DX60, ETERNUS

More information

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE Applied Technology Abstract This white paper is an overview of the tested features and performance enhancing technologies of EMC PowerPath

More information

Technical White Paper August Recovering from Catastrophic Failures Using Data Replicator Software for Data Replication

Technical White Paper August Recovering from Catastrophic Failures Using Data Replicator Software for Data Replication Technical White Paper August 2010 Recovering from Catastrophic Failures Using Data Replicator Software for Data Replication. Recovering from Catastrophic Failures Using Data Replicator Software for Data

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family Version 4.2 Configuring Hosts to Access Fibre Channel (FC) or iscsi Storage 302-002-568 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July

More information

Dell EMC SAN Storage with Video Management Systems

Dell EMC SAN Storage with Video Management Systems Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for

More information

IBM Virtual Machine Manager 2.0

IBM Virtual Machine Manager 2.0 IBM Virtual Machine Manager 2.0 Release Notes Note Before using this information and the product it supports, read the general information in Notices on page 13. Second Edition (August 2005) Copyright

More information

Oracle Enterprise Manager Ops Center. Introduction. Provisioning Oracle Solaris 10 Operating Systems 12c Release 2 ( )

Oracle Enterprise Manager Ops Center. Introduction. Provisioning Oracle Solaris 10 Operating Systems 12c Release 2 ( ) Oracle Enterprise Manager Ops Center Provisioning Oracle Solaris 10 Operating Systems 12c Release 2 (12.2.2.0.0) E47810-03 December 2014 This document provides an end-to-end example for how to use Oracle

More information

iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard

iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard On February 11 th 2003, the Internet Engineering Task Force (IETF) ratified the iscsi standard. The IETF was made up of

More information

IBM XIV Host Attachment Kit for HP-UX Version Release Notes

IBM XIV Host Attachment Kit for HP-UX Version Release Notes IBM XIV Host Attachment Kit for HP-UX Version 2.4.0 Release Notes First Edition (March 2015) This document edition applies to version 2.4.0 of the IBM XIV Host Attachment Kit for HP-UX software package.

More information

IBM. Release Notes November IBM Copy Services Manager. Version 6 Release 1

IBM. Release Notes November IBM Copy Services Manager. Version 6 Release 1 IBM Copy Services Manager IBM Release Notes November 2016 Version 6 Release 1 IBM Copy Services Manager IBM Release Notes November 2016 Version 6 Release 1 Note: Before using this information and the

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (FC/iSCSI) enables SAN tiering Balanced performance well-suited for

More information

OneSign Virtual Appliance Guide

OneSign Virtual Appliance Guide OneSign Virtual Appliance Guide A OneSign Virtual Appliance is a self-contained software implementation of the OneSign server that is functionally equivalent to a OneSign hardware appliance. You host and

More information

Oracle Enterprise Manager Ops Center. Introduction. Creating Oracle Solaris 11 Zones Guide 12c Release 1 ( )

Oracle Enterprise Manager Ops Center. Introduction. Creating Oracle Solaris 11 Zones Guide 12c Release 1 ( ) Oracle Enterprise Manager Ops Center Creating Oracle Solaris 11 Zones Guide 12c Release 1 (12.1.0.0.0) E27336-01 April 2012 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need Oracle Enterprise Manager Ops Center Creating a Server Pool for Oracle VM Server for SPARC 12c Release 2 (12.2.2.0.0) E48147-03 December 2014 This guide provides an end-to-end example for how to use Oracle

More information

November, Executive Summary

November, Executive Summary Bloombase Interoperability Program P1 2011 Bloombase Interoperability of Bloombase StoreSafe and ATTO Celerity Fibre- Channel Host Bus Adapter and ATTO FibreConnect Fibre-Channel Switch for Transparent

More information

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication One Stop Virtualization Shop StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication JUNE 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

Upgrade Express Guide

Upgrade Express Guide ONTAP 9 Upgrade Express Guide December 2017 215-11234_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Cluster software update workflow...

More information

Release Notes P/N REV A03 January 3, 2006

Release Notes P/N REV A03 January 3, 2006 Sun StorEdge Traffic Manager for CLARiiON Release Notes P/N 300-002-978 REV A03 January 3, 2006 These release notes contain supplemental information about Sun StorEdge Traffic Manager for CLARiiON storage

More information

Oracle Enterprise Manager Ops Center E Introduction

Oracle Enterprise Manager Ops Center E Introduction Oracle Enterprise Manager Ops Center Discover an Oracle ZFS Storage Appliance and Configure Storage Libraries 12c Release 2 (12.2.2.0.0) E40770-03 December 2014 This guide provides an end-to-end example

More information

Release Notes and Installation/Upgrade Guide (Release 10.0 PSP6 Update5)

Release Notes and Installation/Upgrade Guide (Release 10.0 PSP6 Update5) Release Notes and Installation/Upgrade Guide (Release 10.0 PSP6 Update5) Cumulative Change Summary Date 10.0 release May 28, 2014 Minor edits to Online Help and Memory Utilization Notes May 30, 2014 Added

More information

iscsi Configuration for ESXi using VSC Express Guide

iscsi Configuration for ESXi using VSC Express Guide ONTAP 9 iscsi Configuration for ESXi using VSC Express Guide May 2018 215-11181_E0 doccomments@netapp.com Updated for ONTAP 9.4 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

IBM XIV Host Attachment Kit for Solaris Version Release Notes

IBM XIV Host Attachment Kit for Solaris Version Release Notes IBM XIV Host Attachment Kit for Solaris Version 2.2.0 Release Notes First Edition (November 2013) This document edition applies to version 2.2.0 of the IBM XIV Host Attachment Kit for Solaris software

More information

Oracle Enterprise Manager Ops Center

Oracle Enterprise Manager Ops Center Oracle Enterprise Manager Ops Center Configure and Install Guest Domains 12c Release 3 (12.3.2.0.0) E60042-03 June 2016 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

Windows Host Utilities Installation and Setup Guide

Windows Host Utilities Installation and Setup Guide IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,

More information

AvePoint Cloud Backup. Release Notes

AvePoint Cloud Backup. Release Notes AvePoint Cloud Backup Release Notes Table of Contents New Features and Improvements... 2 AvePoint Cloud Backup for Office 365 July 2018... 2 AvePoint Cloud Backup for Office 365 June 2018... 2 AvePoint

More information

IBM Storage Host Attachment Kit for HP-UX Version Release Notes IBM

IBM Storage Host Attachment Kit for HP-UX Version Release Notes IBM IBM Storage Host Attachment Kit for HP-UX Version 2.6.0 Release Notes IBM First Edition (April 2016) This document edition applies to version 2.6.0 of the IBM Storage Host Attachment Kit for HP-UX software

More information

IBM XIV Host Attachment Kit for Solaris Version Release Notes IBM

IBM XIV Host Attachment Kit for Solaris Version Release Notes IBM IBM XIV Host Attachment Kit for Solaris Version 2.5.0 Release Notes IBM First Edition (September 2015) This document edition applies to version 2.5.0 of the IBM XIV Host Attachment Kit for Solaris software

More information

OnCommand Unified Manager 7.2: Best Practices Guide

OnCommand Unified Manager 7.2: Best Practices Guide Technical Report OnCommand Unified : Best Practices Guide Dhiman Chakraborty August 2017 TR-4621 Version 1.0 Abstract NetApp OnCommand Unified is the most comprehensive product for managing and monitoring

More information

Technical Committee. ATM User-Network Interface (UNI) Specification Version 4.1

Technical Committee. ATM User-Network Interface (UNI) Specification Version 4.1 Technical Committee ATM User-Network Interface (UNI) Specification Version 4.1 af-arch-0193.000 November 2002 2002 by The ATM Forum. The ATM Forum hereby grants its members the limited right to reproduce

More information

A3800 & A3600. Service Release SR2.1 Release Notes. A-Class. VTrak A-Class firmware version Clients

A3800 & A3600. Service Release SR2.1 Release Notes. A-Class. VTrak A-Class firmware version Clients VTrak A-Class A3800 & A3600 Service Release SR2.1 Release Notes A-Class VTrak A-Class firmware version 1.11.0000.00 Clients VTrak Mac Client Package 1.3.1 42009 VTrak Windows Client Package 1.3.0-40692

More information

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the

More information

Symantec NetBackup Appliance Fibre Channel Guide

Symantec NetBackup Appliance Fibre Channel Guide Symantec NetBackup Appliance Fibre Channel Guide Release 2.6.1.2 NetBackup 52xx and 5330 Symantec NetBackup Appliance Fibre Channel Guide Documentation version: 2.6.1.2 Legal Notice Copyright 2015 Symantec

More information

EMC ViPR Controller. Ingest Services for Existing Environments Guide. Version REV 01

EMC ViPR Controller. Ingest Services for Existing Environments Guide. Version REV 01 EMC ViPR Controller Version 3.5 Ingest Services for Existing Environments Guide 302-003-280 REV 01 Copyright 2013-2016 EMC Corporation. All rights reserved. Published in the USA. Published October 2016

More information

Open-E Data Storage Server. Intel Modular Server

Open-E Data Storage Server. Intel Modular Server Open-E Data Storage Server Intel Modular Server Contents About Open-E Data Storage Server*...4 Hardware Components...5 Installation Software...6 Open-E Data Storage Server* Installation...7 2 www.intel.com/go/esaa

More information

Managing Zone Configuration

Managing Zone Configuration Oracle Enterprise Manager Ops Center Managing the Configuration of a Zone 12c Release 1 (12.1.2.0.0) E27356-01 November 2012 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

Oracle Enterprise Manager Ops Center. Introduction. Creating Oracle Solaris 11 Zones 12c Release 2 ( )

Oracle Enterprise Manager Ops Center. Introduction. Creating Oracle Solaris 11 Zones 12c Release 2 ( ) Oracle Enterprise Manager Ops Center Creating Oracle Solaris 11 Zones 12c Release 2 (12.2.2.0.0) E41230-04 February 2015 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

An Oracle White Paper November Oracle RAC One Node 11g Release 2 User Guide

An Oracle White Paper November Oracle RAC One Node 11g Release 2 User Guide An Oracle White Paper November 2009 Oracle RAC One Node 11g Release 2 User Guide Introduction... 1 Software Installation... 3 How to Configure an Oracle RAC One Node Database... 6 Rolling Patch Application

More information

StarWind Virtual SAN Creating Stand-Alone Image File device

StarWind Virtual SAN Creating Stand-Alone Image File device One Stop Virtualization Shop StarWind Virtual SAN Creating Stand-Alone Image File device JULY 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos

More information

Oracle Enterprise Manager Ops Center. Overview. What You Need. Create Oracle Solaris 10 Zones 12c Release 3 ( )

Oracle Enterprise Manager Ops Center. Overview. What You Need. Create Oracle Solaris 10 Zones 12c Release 3 ( ) Oracle Enterprise Manager Ops Center Create Oracle Solaris 10 Zones 12c Release 3 (12.3.0.0.0) E60027-01 June 2015 This guide provides an end-to-end example for how to use Oracle Enterprise Manager Ops

More information

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs Lenovo ThinkSystem DS2200, DS4200, DS6200 June 2017 David Vestal, WW Product Marketing Lenovo.com/systems Table of Contents Introduction...

More information

IBM XIV Adapter for VMware vcenter Site Recovery Manager 4.x Version User Guide GA

IBM XIV Adapter for VMware vcenter Site Recovery Manager 4.x Version User Guide GA IBM XIV Adapter for VMware vcenter Site Recovery Manager 4.x Version 4.1.0 User Guide GA32-2224-00 Note Before using this document and the product it supports, read the information in Notices on page 35.

More information

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need. Configure and Install Root Domains 12c Release 3 (

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need. Configure and Install Root Domains 12c Release 3 ( Oracle Enterprise Manager Ops Center Configure and Install Root Domains 12c Release 3 (12.3.0.0.0) E60040-01 June 2015 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance

Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance An Oracle Technical White Paper March 2014; v2.1 Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance Introduction... 1 Overview... 2 Prerequisites...

More information