1 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016 Enabled by Hyper-V Virtualization on Windows Server 2016, PowerEdge R740 Servers, and Unity 400 Hybrid Flash Storage January 2018 Abstract This deployment guide describes requirements, configuration details, and steps for deploying SQL Server 2016 and Windows Server 2016 with Hyper-V virtualization on PowerEdge R740 servers and Unity 400 Hybrid Flash storage. H16851R This document is not intended for audiences in China, Hong Kong, Taiwan, and Macao. DEPLOYMENT GUIDE

2 Copyright The information in this publication is provided as is. Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright 2018 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Intel, the Intel logo, the Intel Inside logo, and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries. Other trademarks may be the property of their respective owners. Published in the USA 01/18 H16851R. Dell Inc. believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 2 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

3 Contents Contents Chapter 1 Overview 5 About this guide... 6 Deployment overview... 6 Additional resources... 6 We value your feedback... 7 Chapter 2 Solution Architecture and Requirements 8 Solution architecture... 9 Solution requirements Chapter 3 Network Connectivity 12 End-to-end I/O connectivity Cabling requirements Chapter 4 Pre-Virtualization Configuration 16 Introduction Configuring Dell EMC Networking S4048-ON switches Configuring the idrac IPv4 address Configuring the BIOS Configuring Brocade 6505 Fibre Channel switches Configuring Unity 400 Hybrid Flash storage Chapter 5 Virtualization Configuration 23 Introduction Configuring a virtual disk for OS deployment on the PowerEdge 740 server Configuring prerequisites to install Windows Server Installing Windows Server 2016 OS on the PowerEdge R740 server Installing Broadcom network driver files on Windows Server Enabling Hyper-V, failover clustering, and multipath features in Windows Server Setting up NIC teaming in Windows Server Chapter 6 Post-Virtualization Configuration 28 Configuring SAN switches and Fibre Channel array for Hyper-V Storage specifications Configuring the network in Windows Server Configuring the vethernet switch in Windows Server Renaming and adding servers to the domain DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

4 Contents Installing Dell EMC PowerPath software Adding volumes in the PowerEdge R740 server Chapter 7 Cluster Configuration 35 Creating a cluster Establishing VM-to-SAN connectivity Chapter 8 Deployment Verification 38 Verifying the deployment Chapter 9 SQL Server 2016 Failover Cluster Installation 40 Prerequisites for installing a SQL Server 2016 failover cluster Configuring database VMs Initializing and formatting the storage volumes Installing the failover cluster DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

5 Chapter 1: Overview Chapter 1 Overview This chapter presents the following topics: About this guide... 6 Deployment overview... 6 Additional resources... 6 We value your feedback... 7 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

6 Chapter 1: Overview About this guide Audience and purpose This guide is for IT professionals who want to deploy a virtualized Microsoft SQL Server 2016 solution using Microsoft Hyper-V virtualization on Microsoft Windows Server 2016, Dell EMC PowerEdge R740 servers, and Dell EMC Unity 400 Hybrid Flash storage. Scope This guide provides instructions for deploying the solution. It describes how to set up and configure the following hardware components and to test the infrastructure deployment for component failures: Dell EMC Networking S4048-ON switch Dell EMC PowerEdge R740 server Brocade 6505 switch Dell EMC Unity 400 Hybrid Flash storage Deployment overview This guide also provides information about the installation and configuration of Hyper-V virtualization on Windows Server 2016 and SQL Server The complete deployment sequence for this solution is as follows: 1. Gather all the hardware components according to the solution requirements. 2. Set up the cabling. 3. Perform pre-virtualization configuration. 4. Configure virtualization. 5. Perform post-virtualization configuration. 6. Configure the cluster. 7. Verify the deployment. 8. Install the SQL Server failover cluster. Additional resources Dell EMC Services and Dell EMC certified channel partners provide consulting solutions to help you plan, deploy, and manage even the most advanced and complex virtualized configurations. Additional resources include: Dell EMC Support, which is dedicated to meeting customer requirements with proven services Dell EMC TechCenter, where you can connect with Dell EMC customers and Dell EMC employees to share knowledge, best practices, and information about Dell EMC products and services 6 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

7 Chapter 1: Overview We value your feedback Dell EMC and the authors of this document welcome your feedback on the solution and the solution documentation. Contact with your comments. Authors: Sanjeev Ranjan, Karen Johnson DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

8 Chapter 2: Solution Architecture and Requirements Chapter 2 Solution Architecture and Requirements This chapter presents the following topics: Solution architecture... 9 Solution requirements DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

9 Chapter 2: Solution Architecture and Requirements Solution architecture This solution uses Microsoft SQL Server 2016 architectural design principles and guidelines to achieve balanced virtualization on the PowerEdge R740 server and Unity 400 Hybrid Flash storage arrays. The solution employs Hyper-V virtualization on Windows Server 2016 to build an efficient infrastructure for SQL Server databases. Figure 1 shows the architectural design of the solution. It might not accurately depict all the required hardware components in terms of quantity or sizing. Figure 1. Architecture design DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

10 Chapter 2: Solution Architecture and Requirements Solution requirements Hardware requirements Table 1 lists the solution hardware requirements. Table 1. Hardware requirements Component Servers Specifications Dell EMC PowerEdge R740 Switches Dell EMC Networking S4048-ON Brocade 6505 Network Daughter Card SAN storage Dell Quad Port Broadcom (2 x 10 Gb SFP , 2 x 1 Gb Base-T, rndc) Dell EMC Unity 400 Hybrid Flash Software requirements Table 2 lists the solution software requirements. Table 2. Software requirements Component Specifications Hypervisor Microsoft Hyper-V on Microsoft Windows Server 2016 Guest OS Microsoft Windows 2016 Datacenter Edition Database Microsoft SQL Server 2016 SP 1 Firmware requirements Table 3 and Table 4 list the firmware that we used to deploy and validate the solution. Table 3. Firmware for PowerEdge R740 server Component Version BIOS CPLD idrac9 Enterprise Lifecycle Controller PERC H330 Mini Network Controller Dell Quad Port Broadcom Emulex LightPulse LPe31002-M6-D 2-port 16 Gb Fibre Channel Network drivers Dell Quad Port Broadcom network drivers: (downloaded from Dell.com/support/drivers) 10 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

11 Chapter 2: Solution Architecture and Requirements Table 4. Firmware for switches and Unity 400 Hybrid Flash storage Component Dell EMC Networking S4048-ON Brocade 6505 Dell EMC Unity 400 Hybrid Flash Version 9.8 or later or later OE v or later DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

12 Chapter 3: Network Connectivity Chapter 3 Network Connectivity This chapter presents the following topics: End-to-end I/O connectivity Cabling requirements DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

13 Chapter 3: Network Connectivity End-to-end I/O connectivity The end-to-end I/O connectivity, as shown in Figure 2, consists of multiple port channels and VLT configurations for LAN connectivity. Networking S4048-ON switches provide 10 GbE network connectivity between the compute cluster and the rest of the data center. According to Microsoft SQL Server 2016 best practices and Dell EMC infrastructure design principles, each application network is deployed as a separate workload VLAN that is defined in the data-center core network. All the workload VLANs are created as virtual network adapters on the converged virtual switch across all network connections. The Emulex LightPulse LPe31002 Fibre Channel adapters are used for Fibre Channel connectivity in the host operating system, and virtual Fibre Channel adapters are used for the virtual machines (VMs) that require in-guest Fibre Channel connectivity. Figure 2. End-to-end I/O connectivity DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

14 Chapter 3: Network Connectivity Cabling requirements Connectivity between server and Brocade switches Figure 3 shows the port assignments for Fibre Channel connectivity. Ports 4 and 5 are used to connect Dell EMC storage. The rest of the ports that are marked are used to connect the PowerEdge R740 servers. Connect the cables of the dual-port Emulex LightPulse LPe31002 cards on the PowerEdge R740 server as follows: From the first port of each Emulex card, connect to the first Brocade 6505 switch on ports 0 and 1 respectively. From the second port of each Emulex card, connect to the second Brocade 6505 switch on ports 0 and 1 respectively. Figure 3. Connectivity between server and Brocade switches Connectivity between Unity 400 Hybrid Flash storage and Brocade switches Unity 400 Hybrid Flash storage has two 16 Gb/s Fibre Channel ports from each controller for the front-end connectivity. Connect one port from each controller to switch 1 and connect the remaining port from each controller to switch 2. Figure 4 and Figure 5 illustrate the connections between the storage and the switches. Figure 4. Connections between Unity 400 Hybrid Flash storage and Brocade switches 14 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

15 Chapter 3: Network Connectivity Figure 5. Connectivity between Unity 400 Hybrid Flash storage and Brocade switches DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

16 Chapter 4: Pre-Virtualization Configuration Chapter 4 Pre-Virtualization Configuration This chapter presents the following topics: Introduction Configuring Dell EMC Networking S4048-ON switches Configuring the idrac IPv4 address Configuring the BIOS Configuring Brocade 6505 Fibre Channel switches Configuring Unity 400 Hybrid Flash storage DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

17 Chapter 4: Pre-Virtualization Configuration Introduction Before you set up Hyper-V virtualization on Windows Server 2016 on the virtual infrastructure, configure the following components, as described in this chapter: Dell EMC Networking S4048-ON switches idrac IPv4 address BIOS Brocade 6505 Fibre Channel switches Dell EMC Unity storage Configuring Dell EMC Networking S4048-ON switches Configure the Networking S4048-ON top and S4048-ON bottom switches, one at a time, as follows: 1. Connect to the serial console port on the switch via the CLI. To access the console, connect one end of the serial cable to the console port on the S4048-ON switch, and the other end to the terminal server (laptop). 2. Use HyperTerminal to open the switch console. 3. Configure the following: Hostname: Syntax: hostname <name> configure hostname <name> exit System username and password to access the system remotely: Syntax: username <username> password <password> privilege <privilege level> configure username admin password <password> privilege 15 exit Management IP address for the switches: configure interface ManagementEthernet 1/1 ip address <xxx.xxx.xxx.xxx/xx> no shutdown exit DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

18 Chapter 4: Pre-Virtualization Configuration Login credentials: FTOS(conf) username admin privilege 15 password 0 <yourpassword> FTOS(conf) enable password level 15 0 <yourpassword> 4. Enable the following: Switch ports: FTOS configure FTOS(conf)interface range tengigabitethernet 1/1 1/48 FTOS(conf-if-range-te-1/1-1/48) switchport FTOS(conf-if-range-te-1/1-1/48) no shutdown FTOS(conf-if-range-te-1/1-1/48) exit FTOS(conf) exit MTU Settings frames: FTOS configure FTOS(conf) interface range tengigabitethernet 1/1 1/48 FTOS(conf-if-range-te-1/1-1/48) mtu Configure spanning tree on edge ports: FTOS(conf-if-range-te-1/1-1/48) spanning-tree rstp edge-port FTOS(conf-if-range-te-1/1-1/48) exit 6. Configure the port channel for a link aggregation group (LAG) by typing the following commands to configure the switch interconnect as a LAG: FTOS (conf) interface Port-channel 1 FTOS (conf-if-po-1) mtu FTOS (conf-if-po-1) switchport FTOS(conf-if-po-1) no shutdown FTOS(conf-if-po-1) exit 7. Configure the QSFP ports for the LAG by typing the following commands to assign the 40 Gb QSFP ports to the port channel: FTOS(conf) interface range fortygige 1/49-1/50 FTOS (conf-if-range-fo-1/49-1/50) no ip address FTOS (conf-if-range-fo-1/49-1/50) mtu FTOS (conf-if-range-fo-1/49-1/50) no shutdown FTOS (conf-if-range-fo-1/49-1/50) flowcontrol rx on tx off FTOS (conf-if-range-fo-1/49-1/50) port-channel-protocol lacp FTOS (conf-if-range-fo-1/49-1/50-lacp) port-channel 1 mode active FTOS (conf-if-range-fo-1/49-1/50-lacp) exit FTOS (conf-if-range-fo-1/49-1/50) exit FTOS (conf) exit 18 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

19 Chapter 4: Pre-Virtualization Configuration 8. Configure VLANs: VLAN 10 for the host management network: configure interface vlan 10 description hostmanagement ip address <xxx.xxx.xxx.xxx/xx> tagged port- channel 1 tagged tengigabitethernet 1/1 1/4 no shutdown exit VLAN 20 for the cluster network: configure interface vlan 20 description Cluster ip address <xxx.xxx.xxx.xxx/xx> tagged port- channel 1 tagged tengigabitethernet 1/5 1/8 no shutdown exit VLAN 30 for the live migration network: configure interface vlan 30 description Live Migration ip address <xxx.xxx.xxx.xxx/xx> tagged port- channel 1 tagged tengigabitethernet 1/9 1/12 no shutdown exit VLAN 50 for the application network: configure interface vlan 50 description Application Network ip address <xxx.xxx.xxx.xxx/xx> tagged port-channel 1 tagged tengigabitethernet 1/13 1/16 no shutdown exit VLAN 60 for the front-end network: configure interface vlan 60 description Front End Network ip address <xxx.xxx.xxx.xxx/xx> tagged port-channel 1 tagged tengigabitethernet 1/17 1/20 no shutdown exit VLAN 70 for the SQL private network: configure interface vlan 70 description SQL Private Network ip address <xxx.xxx.xxx.xxx/xx> tagged port-channel 1 tagged tengigabitethernet 1/21 1/24 no shutdown exit DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

20 Chapter 4: Pre-Virtualization Configuration 9. Save the configuration: FTOS copy running-config startup-config Verifying Networking S4048-ON switch configuration Verify the Networking S4048-ON switch configuration as follows: 1. Confirm that the VLT domain status is Up: show vlt brief 2. Confirm that port-channel 100 status is Up: show interfaces port-channel Confirm that port-channel 100 is tagged on the VLAN interfaces (10, 20, 30): show vlan 4. Confirm that the port-channel interfaces are Up, port-channel 100 consists of interfaces 1/2, 1/4, and 1/6, and the interface statuses are Up: show interfaces port-channel 100 brief Configuring the idrac IPv4 address Configure the idrac IPv4 address: 1. Turn on or restart the server. 2. At F2=System Setup, press F2. 3. In the System Setup Main Menu, click idrac Settings, and then click Network. 4. In IPv4 SETTINGS, type the following information: Starting IP Address Starting Gateway Starting Subnet Mask 5. Click Back, and then in System Setup, click Finish. 6. When the confirmation message appears, click Yes. Configuring the BIOS Configure the BIOS: 1. Turn on or restart the server. 2. At F2=System Setup, press F2. 3. Ensure that the logical processor is enabled: In System Setup Main Menu, click System BIOS > Processor Settings. In Processor Settings, verify that Processor Settings is set to Enabled. 20 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

21 4. Ensure that Virtualization Technology is enabled: Chapter 4: Pre-Virtualization Configuration In System Setup Main Menu, click System BIOS > Processor Settings. In Processor Settings, verify that Virtualization Technology is set to Enabled. Configuring Brocade 6505 Fibre Channel switches After racking and cabling the SAN switches, configure the switches by performing the following tasks: 1. Assign the management IP address for the switch. 2. Access the Brocade switch through Web Tools. 3. Enable Dynamic Ports on Demand. Assigning the management IP address to the SAN switches Assign the management IP address to the SAN switches: 1. Connect one end of the serial cable to the RJ-45 serial port on the switch, and the other end to the serial port on the server (workstation). 2. Use HyperTerminal to open the switch console. 3. In the console, configure the serial connection settings as follows: Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None 4. Log in to the switch by using the default username and password. 5. Assign the management IP address for the switch: switch: admin> ipaddrset Ethernet IP Address <IP address> Ethernet Subnetmask <subnet mask> Gateway IP Address <gateway> DHCP [Off]: off Accessing the Brocade switch through Web Tools Brocade Web Tools is an embedded UI that enables administrators to monitor and manage single or small fabrics, switches, and ports. Launch Web Tools directly from a web browser: 1. Open the web browser, type the IP address of the switch in the address field, and press Enter. 2. In the Please Login dialog box, type the username and password, and then click OK. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

22 Chapter 4: Pre-Virtualization Configuration Enabling Dynamic Ports on Demand The Dynamic Ports on Demand (POD) feature automatically assigns POD licenses from a pool of available licenses that is based on the server blade or switch installation. Enable the Dynamic POD feature: 1. Connect to the switch and log in as an administrator. 2. Type the following command to change the license assignment method to dynamic: switch: admin> licenseport --method dynamic 3. Type the following command to restart the switch: switch: admin> reboot Configuring Unity 400 Hybrid Flash storage Dell EMC Professional Services or Certified Channel Partners perform the initial setup of Unity 400 Hybrid Flash storage. 22 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

23 Chapter 5: Virtualization Configuration Chapter 5 Virtualization Configuration This chapter presents the following topics: Introduction Configuring a virtual disk for OS deployment on the PowerEdge 740 server Configuring prerequisites to install Windows Server Installing Windows Server 2016 OS on the PowerEdge R740 server Installing Broadcom network driver files on Windows Server Enabling Hyper-V, failover clustering, and multipath features in Windows Server Setting up NIC teaming in Windows Server DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

24 Chapter 5: Virtualization Configuration Introduction To set up virtualization, perform the following tasks, as described in this chapter: 1. Configure a virtual disk for OS deployment on the PowerEdge R740 server. 2. Configure prerequisites to install Windows Server. 3. Install the Windows Server 2016 operating system on the PowerEdge R740 server. 4. Install Broadcom network driver files on Windows Server Enable Hyper-V and multipath features in Windows Server Set up NIC teaming in Windows Server Configuring a virtual disk for OS deployment on the PowerEdge 740 server Configure a virtual disk for OS deployment on the PowerEdge 740 server: 1. Log in to idrac and launch the virtual console. 2. From the Power menu, select Power on the system. 3. When the following message appears, click Yes: You are about to execute a server control action. Are you sure you want to continue? The system restarts. 4. To run the RAID configuration utility, press Ctrl-R when the following message appears: press CTRL + R to Run configuration utility 5. In the configuration utility, select PERC H730 Mini, and then press F2 to enable operations. 6. From the list box, select Create New VD. 7. Set RAID Level to RAID-1, select physical disks, set the basic settings, use default virtual disk size, virtual disk name, and then click OK. Note: The OS partition is not I/O intensive. RAID 1 is recommended for OS partitions so that they have hardware redundancy. 8. When the following message appears, click OK: It is recommended that all newly created logical drives be initialized unless you are attempting to recreate a previous configuration and recover data as initialization is a destructive process. Are you sure you want to skip initialization? The virtual disk is created. 9. Exit Setup and restart the server. 24 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

25 Configuring prerequisites to install Windows Server Configure the prerequisites to install Windows Server: 1. Map the virtual disk: Chapter 5: Virtualization Configuration In the virtual console, click Connect Virtual Media, and then click Map CD/DVD. In the Drive/Image File dialog box, provide the drive location, and then click Map Device. 2. Set the boot device and load the OS executable files: In the virtual console, select Next Boot, and then select Virtual CD/DVD/ISO. When the following message appears, click OK: The selected device is set as the boot device for the next boot until another user changes the selected boot device. Therefore, it is recommended to reboot the server immediately after saving this selection. Click OK to save the selection. Virtual CD/DVD/ISO is set as the boot device. Restart the server. Installing Windows Server 2016 OS on the PowerEdge R740 server Install Windows Server 2016 on the PowerEdge R740 server: 1. Power on the server and press any key after you see the following message: Booting from Virtual CD Press any key to boot from CD or DVD. The Windows Server setup appears. 2. Select language preference, time and currency format, and keyboard or input method, and then click Next. 3. In Windows Setup, click Install now. 4. Type the product key, and then click Next. 5. Select OS - Windows Server 2016 Datacenter (Server with GUI), and then click Next. 6. In License terms, select I accept the license terms, and then click Next. 7. In Installation type, select Custom: Install windows only (advanced). 8. Select Drive0 Unallocated Space and click New to create the partition, and then click Next > Next. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

26 Chapter 5: Virtualization Configuration 9. When the following message appears, click OK: To ensure that all Windows features work correctly, Windows might create additional partitions for system files 10. After the installation is complete, on the Settings page, set the username and password. Installing Broadcom network driver files on Windows Server 2016 Install the Broadcom network driver files on Windows Server 2016: 1. Log in to the PowerEdge R740 server. 2. Copy the Broadcom network driver for 64-bit Windows to a location on the PowerEdge R740 server. 3. Run the network driver installer. 4. On the welcome screen, click Next. 5. At the License Agreement, select I accept the terms in the license agreement, and then click Next. 6. In Custom Setup, select the default settings, and then click Next. 7. At Ready to Install the Program, click Install. 8. In InstallShield Wizard, click Finish. 9. To view the network card, on the Windows desktop, click Start, select Run, and then type ncpa.cpl. The Network Connections page displays all the NIC cards. Enabling Hyper-V, failover clustering, and multipath features in Windows Server 2016 Type the following Windows PowerShell command to install Windows features. Note: In Windows Server 2016, run the Windows PowerShell command as an administrator. This step requires a restart. Install-WindowsFeature Name Failover-Clustering, Multipath-IO, Hyper-V IncludeManagementTools Restart Setting up NIC teaming in Windows Server 2016 Set up NIC teaming in Windows Server 2016: 1. In Server Manager, select Local Server. 2. In Properties, click NIC Teaming status Disabled. 3. In NIC Teaming, from TASKS, select New Team. 26 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

27 Chapter 5: Virtualization Configuration 4. In New team, type the team name, for example ConvergedNet Team, and select the NICs that you want to include in the team. 5. In Additional properties, set Teaming mode to Switch Independent and Load balancing mode to Dynamic, and then click OK. Note: The dynamic mode is a new feature of Windows Server The load balancing algorithm, which balances traffic using flowlets, can spread both inbound and outbound traffic. The Hyper-V port algorithm forces all VM traffic only through one physical NIC, whereas the dynamic mode spreads traffic across all the NICs, regardless of workload. 6. Verify that the NICs are active. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

28 Chapter 6: Post-Virtualization Configuration Chapter 6 Post-Virtualization Configuration This chapter presents the following topics: Configuring SAN switches and Fibre Channel array for Hyper-V Storage specifications Configuring the network in Windows Server Configuring the vethernet switch in Windows Server Renaming and adding servers to the domain Installing Dell EMC PowerPath software Adding volumes in the PowerEdge R740 server DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

29 Chapter 6: Post-Virtualization Configuration Configuring SAN switches and Fibre Channel array for Hyper-V To map storage volumes to the Hyper-V cluster, perform the following tasks, as described in this section: 1. Create a zone configuration. 2. Create a zone alias to easily manage the zone configuration. 3. Create zones. 4. Enable the zone configuration. 5. Create a storage pool. 6. Add the host to the Unity 400 storage. 7. Create a LUN and map it to the host. Creating a zone configuration Creating a zone alias Create and enable a zone configuration: 1. In Web Tools, select the switch from the Fabric tree. 2. Click Configure, and then click Zone Admin. 3. In Zone Administration, from the New list box, select New Zone Config. 4. In the Create New Config dialog box, type a name for the new configuration, and then click OK. Create a zone alias: 1. In Web Tools, select the switch from the Fabric tree. 2. Click Configure > Zone Admin. 3. In the Zone Administration window, from the New list box, click New Alias. 4. In the Create New Alias dialog box, type a name for the new alias and click OK. For example, server ports, storage ports. 5. Expand the Member Selection List to view the nested elements. 6. Click the ports that are connected. 7. Click the World Wide Name (WWN) of the card, and then click the right arrow to add the WWN to alias members. 8. Repeat the preceding steps to create an alias for all the servers and storage physical ports and virtual ports. 9. Click Action > Save Config to save the configuration changes. Note: You can also view the WWN of the servers from the idrac console. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

30 Chapter 6: Post-Virtualization Configuration Creating zones Enabling the zone configuration Create zones: 1. In Web Tools, select the switch from the Fabric tree. 2. Click Configure > Zone Admin. 3. In the Zone Administration window, from the New list box, click New Zone. 4. In the Create New Zone dialog box, type a name for the new zone, and click OK. 5. Expand Member Selection List to view the nested elements. 6. In Member Selection List, select the storage virtual ports and server ports alias that you want to include in the zone. 7. Click the right arrow to add the zone members to the zone alias. 8. Select Zoning Actions > Save Config to save the configuration changes. 9. Repeat the preceding steps to create zones for all the servers and storage virtual ports. Enable the zone configuration: 1. In Web Tools, select the switch from the Fabric tree. 2. Click Configure > Zone Admin. 3. In the Zone Administration window, click the Zone Config tab. 4. Expand Member Selection List to view the nested elements. 5. In Member Selection List, select the zones that you have created. 6. Click the right arrow to add the zones. 7. Select Zoning Actions > Save Config to save the configuration changes. 8. On the toolbar, click Enable Config. 9. In the Choose Zone Config to be enabled dialog box, select the config, and click OK. 10. Click Yes to confirm that you want to enable the configuration. The Brocade switch for SAN connectivity is configured and enabled. Creating a storage pool Create a storage pool: 1. Log in to the Unisphere DBUnity 400 dashboard. 2. In the left panel, go to Storage > Pools, and click the plus sign (+). 3. In the Create Pool window, type the name of the pool and then click Next. 4. Select the type of tier from the available options Extreme Performance, Performance, and Capacity. 5. Select Use FAST Cache if you want to enable FAST cache for this pool. 6. Select a RAID configuration for the drives. 7. Click Next. 30 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

31 Chapter 6: Post-Virtualization Configuration 8. In the Summary window, select the drives to be included in the pool. 9. Verify the total capacity of the pool. 10. Click Finish. Adding the host to the Unity 400 Add the host to the Unity 400: 1. Log in to the Unisphere DBUnity 400 dashboard. 2. In the left panel, go to Access > Hosts, click the plus sign (+), and then select Host. 3. In the Add a Host window, type the following details: Hostname Operating system Network address (IP of the host) 4. Click Next. 5. In the Initiators window, select Initiator WWN, and then click Next. 6. In the Summary window, click Finish. Creating a LUN and mapping it to the host Create a LUN and map it to the host: 1. Log in to the Unisphere DBUnity 400 dashboard. 2. In the left panel, go to Storage > Block, and click the plus sign (+). The Create LUN window opens. 3. In the Configure tab, type or select the following details: Number of LUNs Name of the LUN Pool (select the pool that you created from the list of pools) Tiering policy (choose one of the options Start High Then Auto-Tier, Highest Available Tier, and Lowest Available Tier) Size of the pool Host I/O limit (select No Limit) 4. In the Access tab, click the plus sign (+). 5. In the Select Host Access window, select the hostname that you configured earlier. 6. Click OK. 7. Click Next. 8. In the Summary window, click Finish. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

32 Chapter 6: Post-Virtualization Configuration Storage specifications Typically, you can enhance SQL Server performance by placing the database and transaction log files on separate drives. Read I/O for database files is typically random while the I/O for the transaction log is typically sequential. Table 5 lists the storage specifications for the Hyper-V cluster and the SQL Server databases. Table 5. Storage specifications Storage specification Number of volumes Size of each volume Hyper-V cluster Clustered shared volume for hosting VMs 1 2 TB Quorum volume 1 1 GB SQL Server database servers SQL Server datafile 1 1 TB SQL Server log file GB tempdb GB Quorum volume (guest clustering) 1 1 GB Configuring the network in Windows Server 2016 On the PowerEdge R740 server, start Windows PowerShell and configure the network: 1. Create a VM switch: New-VMSwitch AllowManagementOS 1 Name ConvergedNetSwitch MinimumBandwidthmode weight Verbose NetAdapterName: ConvergedNet Team 2. Create a VM network adapter for the cluster: Add-VMNetworkAdapter ManagementOS SwitchName ConvergedNetSwitch Name Cluster Verbose 3. Create a VM network adapter for a live migration: Add-VMNetworkAdapter ManagementOS SwitchName ConvergedNetSwitch Name LiveMigration Verbose 4. Set VLAN access properties for the management network adapter: Set-VMNetworkAdapterVlan ManagementOS VMNetworkAdapterName ConvergedNetSwitch Access VlanId Set VLAN access properties for the cluster network adapter: Set-VMNetworkAdapterVlan ManagementOS VMNetworkAdapterName Cluster Access VlanId DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

33 6. Set VLAN access properties to LiveMigration: Chapter 6: Post-Virtualization Configuration Set-VMNetworkAdapterVlan ManagementOS VMNetworkAdapterName LiveMigration Access VlanId Set the minimum bandwidth reservation for the management network adapter: Set-VMNetworkAdapter -ManagementOS -Name ConvergedNetSwitch -MinimumBandwidthWeight 5 8. Set the minimum bandwidth reservation for the cluster network adapter: Set-VMNetworkAdapter -ManagementOS -Name Cluster - MinimumBandwidthWeight Set the minimum bandwidth reservation for the live migration network adapter: Set-VMNetworkAdapter -ManagementOS -Name LiveMigration - MinimumBandwidthWeight 20 Note: In Network Connections, you can view vethernet (ConvergedNetSwitch) and adapters for the cluster and live migration networks. Configuring the vethernet switch in Windows Server 2016 Configure the vethernet switch: 1. In Network Connections, right-click vethernet (ConvergedNetSwitch), and select Properties from the list box. 2. In vethernet (ConvergedNetSwitch) Properties, configure IPV4 protocol properties, include the IP address and DNS server details, and then click OK. 3. Ping the VLAN 10 network to test the network connection. Renaming and adding servers to the domain Rename and add servers to the domain: 1. Type the following Windows PowerShell command: Add-Computer -DomainName <domainname> -NewName <Hostname> Restart -Force 2. At the Windows prompt, type the credentials of the domain controller. Installing Dell EMC PowerPath software Install Dell EMC PowerPath software: 1. Download the PowerPath software from the Dell EMC website. 2. Follow the instructions in the installation wizard to install the software. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

34 Chapter 6: Post-Virtualization Configuration 3. Activate the PowerPath software using the license key that you received when you purchased it. Adding volumes in the PowerEdge R740 server Add volumes in the PowerEdge R740 server: 1. Log in to the PowerEdge R740 server and, in Run, type: diskmgmt.msc 2. In Disk Management: Right-click New Disk and select Online. Right-click the disk and select Initialize disk. Right-click the disk and select New Simple Volume. 3. In the New Simple Volume wizard, click Next. 4. In Specify volume size in MB, use the default disk size, and then click Next. 5. In Assign Driver Letter or Path, select Do not assign a driver letter or driver path, and then click Next. 6. In Format Partition: Select Format this volume with the following settings. Set File system to NTFS, Allocation unit size to 64fK, and Volume label to Quorum. Select perform a quick format. Click Next. 7. In the Completing the New Simple Volume wizard, click Finish. 8. Repeat the preceding steps to create the second volume for storing the VHD files of the VMs. 34 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

35 Chapter 7: Cluster Configuration Chapter 7 Cluster Configuration This chapter presents the following topics: Creating a cluster Establishing VM-to-SAN connectivity DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

36 Chapter 7: Cluster Configuration Creating a cluster Overview Perform the following tasks on any one of the nodes that you are going to add to the cluster: 1. Validate configuration. 2. Create a Hyper-V host cluster. Perform the tasks as described in this section only once. Prerequisite Ensure that you are logged in with a domain account that has administrative privileges. Validating the configuration The following command initiates a series of tests to verify if the configuration meets the guidelines for failover clustering: Test-Cluster Node "Node1", "Node2" -Include "Storage", Inventory, Network, "System Configuration" After the test is complete, the tool displays the results. If any messages indicate failures with the tests, resolve the issues before proceeding. Creating a Hyper-V host cluster The following command creates a two-node cluster with a static IP address, which is used for the cluster s management connection: New-Cluster Name <"ClusterName"> Node "Node1", "Node2" StaticAddress <IPaddress> Establishing VM-to-SAN connectivity Overview The Virtual Fibre Channel feature in Hyper-V makes it possible for a VM to connect directly to a SAN through a virtualized Fibre Channel adapter. Establishing connectivity to the SAN by using a virtual Fibre Channel adapter is a two-step process. Create a VMware vsan, and then add a virtual Fibre Channel adapter to the VM and connect it to the vsan. Creating a vsan Create a vsan: 1. On the Windows Start screen, click Server Manager. 2. Click Tools, and then click Hyper-V Manager. 3. In the Action panel, click Virtual SAN Manager. 4. Click Create. 5. In the Name field, type the name for the new vsan. 6. In the Notes field, type any notes that are important for the vsan. 7. Ensure that you select at least one available WWN for the vsan to be used by the virtual Fibre Channel adapter. 36 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

37 Chapter 7: Cluster Configuration 8. Click OK to create the vsan. 9. In Hyper-V Manager, click Virtual SAN Manager to see the new vsan. Adding and connecting a virtual Fibre Channel adapter to vsan Add and connect a virtual Fibre Channel adapter: 1. On the Windows Start screen, click Server Manager. 2. Click Tools, and then click Hyper-V Manager. 3. In Hyper-V Manager, under Virtual Machines, click the name of the VM that you want to add. 4. In the Action panel, click Settings. In Add Hardware, you can view a list of hardware options that you can add to the VM. 5. Click Fibre Channel Adapter, and then click Add. 6. In Settings, connect the virtual Fibre Channel adapter to a vsan that you previously created: Click the Virtual SAN list box that shows Not connected. Click the name of the required vsan. 7. Configure the WWNs (Set A and Set B) for the virtual Fibre Channel adapter. You can use the automatically generated default WWNs or manually assign them. Configure both WWN sets to ensure a successful live migration of the VM. Creating a VM Create a VM, running the PowerShell commands as an administrator: 1. Create fixed VHD for better I/O performance: $VHDPath="C:\ClusteredStorage\volume1\HDD\<HDDname>.vhdx" New-VHD -SizeBytes <size> Path $VHDPath Fixed 2. Create a VM: $VMPath="C:\ClusteredStorage\volume1\VMs\<VMname>" New-VM -Name SP -Path $VMPath -MemoryStartupBytes <Memory> - BootDevice CD -SwitchName <switchname> -VHDPath $VHDPath 3. Configure the VM: Set-VMProcessor -VMName DB -Count <vcpu count> Add-VMNetworkAdapter -VMName <VMName> -Name <Virtual Network adapter> Set-VMNetworkAdapterVlan -VMName <VMName> -VMNetworkAdapterName <Virtual Network adapter> - Access -VlanId <VLANID> 4. Add the vsan switches to the VM: Add-VMFibreChannelHba VMName <VMName> SanName <vsan switch name1> Add-VMFibreChannelHba VMName <VMname> SanName <vsan switch name2> DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

38 Chapter 8: Deployment Verification Chapter 8 Deployment Verification This chapter presents the following topics: Verifying the deployment DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

39 Chapter 8: Deployment Verification Verifying the deployment After you complete the deployment, verify the solution as follows: 1. Create VMs. 2. Migrate VMs across the cluster and check to see if the migration is progressing without any interruption. 3. Shut down one of the hosts and check to see if the VMs on that host are migrating within the cluster. 4. Power off one of the S4048-ON network switches and ensure that the VMs are running without any network loss. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

40 Chapter 9: SQL Server 2016 Failover Cluster Installation Chapter 9 SQL Server 2016 Failover Cluster Installation This chapter presents the following topics: Prerequisites for installing a SQL Server 2016 failover cluster Configuring database VMs Initializing and formatting the storage volumes Installing the failover cluster DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

41 Chapter 9: SQL Server 2016 Failover Cluster Installation Prerequisites for installing a SQL Server 2016 failover cluster Before you install a SQL Server 2016 failover cluster, ensure that you have completed these steps: 1. Created a VM 2. Installed the operating system 3. Renamed and added a guest Windows server to the domain 4. Installed PowerPath software Configuring database VMs 5. Installed and configured Windows failover clustering Table 6 lists the specifications for the database VMs. Table 6. Configuring database VMs Component Specification vcpus 24 Memory Memory for database Size of database LUN Size of log LUN Size of tempdb LUN 160 GB 128 GB 600 GB 100 GB 100 GB Initializing and formatting the storage volumes The storage volumes are formatted with a 64 KB allocation unit to maximize the disk performance. Initialize and format the storage volumes on all the database server nodes by running the PowerShell commands in the following procedure. Note: Ensure that both the database servers are assigned the same drive letter for a LUN. 1. Get newly added storage volumes: Get-Disk where-object Isoffline -eq $True 2. Initialize the disk: Initialize-Disk -Number 1 -PartitionStyle MBR 3. Partition the disk: New-Partition -DiskNumber 1 -DriveLetter 'E' UseMaximumSize DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

42 Chapter 9: SQL Server 2016 Failover Cluster Installation 4. Format the volume: Format-Volume -DriveLetter 'E' -FileSystem NTFS - AllocationUnitSize Confirm:$false 5. Repeat the preceding steps for all the storage volumes that are assigned to the server. Installing the failover cluster Before you install the failover cluster, ensure that the SQL Server installation media is ready to start the installation. Install a SQL Server cluster instance by first running the setup in the first node. After the initial installation in the first node, run setup.exe in all the other nodes where you want to install the SQL Server clustered instance. Installing the SQL Server failover cluster in the first node Install the SQL Server failover cluster in the first node: 1. Initiate the installation: Run Setup.exe as an administrator. In the SQL Server Installation Center window, select Installation in the left panel, and then click New SQL Server failover cluster installation. In Product key, type the product key, and then click Next. In License Terms, select I Accept the license terms, and then click Next. The installation wizard identifies any issues in the Global Rules window and reports them. In Microsoft Update, select Use Microsoft Update to check for updates (recommended), and then click Next. 2. Click Next and continue with the installation: In Install Failover Cluster Rules, review and resolve any reported errors, and then click Next. In Setup Role, select SQL Server Feature Installation, and then click Next. In Feature Selection, select Database Engine Services and Management Tools - Basic, and then click Next. In Feature Rules, ensure that all the rules have passed, and then click Next. In Instance Configuration, type the SQL Server instance network name in SQL Server Network Name, and then click Next. In Cluster Resource Group, type the SQL Server cluster resource group name in SQL Server Cluster Resource Group Name, and then click Next. In Cluster Disk Selection, select the default cluster disk, and then click Next. In Cluster Network Configuration, select the IPv4 network and configure the IP address. 42 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

43 In Server Configuration: i ii iii Chapter 9: SQL Server 2016 Failover Cluster Installation On the Service Accounts tab, specify the domain accounts and passwords for the SQL Server agent and SQL Server engine. On the Collation tab, click Customize, and then select SQL_Latin1_General_CP1_CI_AS for the SQL collation. Select Grant Perform Volume Maintenance Task privilege to SQL Server Database Engine Service. In the Server Configuration tab of Database Engine Configuration, select Windows authentication mode, and then click Add to enter the SQL server administrators. In Database Engine Configuration: i ii Click the Data Directories tab. To store the SQL database files, define the paths for disks or paths of the root for the following: System databases directory User databases Log files Backup files tempdb Click Next. In Feature Configuration, click Next. In Ready to Install, review all the displayed configurations, and then click Install. The wizard displays the installation progress. 3. In the Complete window, verify that all the items have been successfully installed, and then click Close. 4. Add the other nodes to the SQL Server failover clustered instance. Installing SQL Server 2016 failover cluster in the second node Install the SQL Server failover cluster in the second node: 1. Initiate the installation: Run Setup.exe as an administrator. In the SQL Server Installation Center window, select Installation in the left panel, and then click Add node to a SQL Server failover cluster. In Product key, verify the product key, and then click Next. In License Terms, select I Accept the license terms, and then click Next. The installation wizard identifies any issues in the Global Rules window and reports them. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

44 Chapter 9: SQL Server 2016 Failover Cluster Installation In Microsoft Update, select Use Microsoft Update to check for updates (recommended), and then click Next. 2. Continue with the installation: In Node Rules, review and resolve any reported errors, and then click Next. In Cluster Nodes Configuration, select the SQL Server instance that you want to add to the node. In Cluster Network Configuration, select the IPv4 network and configure the IP address. In Service Accounts, type and confirm the SQL Server agent and SQL Server engine passwords. In Feature Rules, review all the displayed rules, and then click Next. In Ready to Add Node, confirm the settings, and then click Install. The wizard displays the installation progress and prompts you with the completed window after the installation is over. 3. Click Close to exit the installation wizard. The SQL Server failover cluster installation is now complete. Configuring SQL Server 2016 To get the best database performance, perform these steps: 1. Open SQL Server Management Studio and click New Query. 2. Set the maximum memory by typing the following SQL query: sp_configure 'show advanced options', 1; GO RECONFIGURE; GO sp_configure 'max server memory', <'Memory in MB'>; GO RECONFIGURE; GO 3. Set MAXDOP to 0 by typing the following SQL query: USE Master: GO EXEC sp_configure 'show advanced options', 1; GO RECONFIGURE WITH OVERRIDE; GO EXEC sp_configure 'max degree of parallelism', 0; GO RECONFIGURE WITH OVERRIDE; GO 44 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

45 Chapter 9: SQL Server 2016 Failover Cluster Installation 4. Move the tempdb to a different volume to isolate the tempdb I/O operations from other databases: Open SQL Server Management Studio, and click New Query. Type the following SQL query to move the tempdb files: USE master; GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp, FILENAME = 'E:\SQLData\tempdb.mdf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp2, FILENAME = 'E:\SQLData\tempdb_mssql_2.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp3, FILENAME = 'E:\SQLData\tempdb_mssql_3.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp4, FILENAME = 'E:\SQLData\tempdb_mssql_4.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp5, FILENAME = 'E:\SQLData\tempdb_mssql_5.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp6, FILENAME = 'E:\SQLData\tempdb_mssql_6.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp7, FILENAME = 'E:\SQLData\tempdb_mssql_7.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = temp8, FILENAME = 'E:\SQLData\tempdb_mssql_8.ndf'); GO ALTER DATABASE tempdb MODIFY FILE (NAME = templog, FILENAME = 'E:\SQLLog\templog.ldf'); GO 5. Restart the SQL Server service. DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER

Microsoft SharePoint Server 2013 on Dell PowerEdge R630 with Microsoft Hyper-V Virutalization Deployment Guide

Microsoft SharePoint Server 2013 on Dell PowerEdge R630 with Microsoft Hyper-V Virutalization Deployment Guide Microsoft SharePoint Server 2013 on Dell PowerEdge R630 with Microsoft Hyper-V Virutalization Deployment Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

Deploying the 200TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R940 and SC9000

Deploying the 200TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R940 and SC9000 Deploying the 200TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R940 and SC9000 Deployment guide with step-by-step instructions Abstract This

More information

Deploying the 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020

Deploying the 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020 Deploying the 60TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2016 using Dell EMC PowerEdge R730 and SC5020 Deployment guide with step-by-step instructions Abstract This

More information

Deploying the 8TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R740 and SCv3020

Deploying the 8TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R740 and SCv3020 Deploying the 8TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using Dell EMC PowerEdge R740 and SCv3020 Deployment guide with step-by-step instructions Abstract This

More information

17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S

17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S 17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S Deployment Guide Dell Engineering December 2015 A Dell Deployment and

More information

Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage

Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage January 2019 H17514 Abstract This deployment guide describes how to implement a converged infrastructure for Microsoft

More information

Dell EMC vsan Ready Nodes for VDI

Dell EMC vsan Ready Nodes for VDI Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016 DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016 Enabled by Hyper-V on Windows Server 2016, PowerEdge R740 Servers, and Unity 400 Hybrid Flash Storage January 2018 Abstract This design guide describes

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Dell Storage Engineering December 2015 A Dell Deployment and

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

Dell EMC Ready Solutions for Oracle with Dell EMC XtremIO X2 and Data Domain

Dell EMC Ready Solutions for Oracle with Dell EMC XtremIO X2 and Data Domain Dell EMC Ready Solutions for Oracle with Dell EMC XtremIO X2 and Data Domain November 2018 Abstract This deployment guide describes the design and deployment of the mixed Oracle database environments that

More information

21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide

21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide 21 TB Data Warehouse Fast Track for Microsoft SQL Server 2014 Using the PowerEdge R730xd Server Deployment Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

Dell EMC Ready Solutions for Microsoft WSSD QuickStart Configurations for ROBO and Edge Environments. Integration and Deployment Guidance

Dell EMC Ready Solutions for Microsoft WSSD QuickStart Configurations for ROBO and Edge Environments. Integration and Deployment Guidance Dell EMC Ready Solutions for Microsoft WSSD QuickStart Configurations for ROBO and Edge Environments Integration and Deployment Guidance Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for Citrix XenDesktop and XenApp for Dell EMC XC Family September 2018 H17388 Deployment Guide Abstract This deployment guide provides instructions for deploying

More information

Installation and Configuration Guide for Microsoft Exchange Server 2013

Installation and Configuration Guide for Microsoft Exchange Server 2013 Installation and Configuration Guide for Microsoft Exchange Server 2013 Last update: 25 January 2016 Designed for organizations implementing Exchange 2013 in a virtual environment Includes step-by-step

More information

Dell EMC Ready System for VDI on VxRail

Dell EMC Ready System for VDI on VxRail Dell EMC Ready System for VDI on VxRail Citrix XenDesktop for Dell EMC VxRail Hyperconverged Appliance April 2018 H16968.1 Deployment Guide Abstract This deployment guide provides instructions for deploying

More information

Dell Force10 S4810 Switch

Dell Force10 S4810 Switch Rapid EqualLogic Configuration Series Dell Force10 S4810 Switch Implementation Guide June 2012 SISfeedback@Dell.com Revisions Date April 2012 June 2012 Description initial release Added optional stack

More information

Dell Force10 S4810 Switch

Dell Force10 S4810 Switch Dell Force10 S4810 Switch Rapid EqualLogic Configuration Series Implementation Guide February 2013 Revisions Date April 2012 June 2012 Description initial release Added optional stack configuration October

More information

Dell EMC Ready Stack Deployment Guide for VMware vsphere and Unity

Dell EMC Ready Stack Deployment Guide for VMware vsphere and Unity Dell EMC Ready Stack Deployment Guide for VMware vsphere and Unity January 2019 H17588 A Dell EMC Deployment and Configuration Guide The information in this publication is provided as is. Dell Inc. makes

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE Design Guide APRIL 0 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

Dell EMC Ready Solution for VMware vcloud NFV 3.0 OpenStack Edition Platform

Dell EMC Ready Solution for VMware vcloud NFV 3.0 OpenStack Edition Platform Dell EMC Ready Solution for VMware vcloud NFV 3.0 OpenStack Edition Platform Deployment Automation Operations Guide for VMware NFV 3.0 with VMware Integrated OpenStack 5.0 with Kubernetes Dell Engineering

More information

VMware vsphere Storage Appliance Installation and Configuration

VMware vsphere Storage Appliance Installation and Configuration VMware vsphere Storage Appliance Installation and Configuration vsphere Storage Appliance 1.0 vsphere 5.0 This document supports the version of each product listed and supports all subsequent versions

More information

Dell Networking S60 and Dell Force10 S60

Dell Networking S60 and Dell Force10 S60 Dell Networking S60 and Dell Force10 S60 Switch Configuration Guide for EqualLogic SANs Dell Storage Engineering September 2013 SISfeedback@Dell.com Revisions March 2013 Initial release September 2013

More information

Dell EMC Networking S6010-ON

Dell EMC Networking S6010-ON Dell EMC Networking S6010-ON Switch Configuration Guide for Dell PS Series SANs Abstract This document illustrates how to configure Dell EMC Networking S6010-ON switches for use with Dell PS Series storage

More information

Dell Networking S6000

Dell Networking S6000 Dell Networking S6000 Switch Configuration Guide for PS Series SANs Dell Storage Engineering February 2016 A Dell Deployment and Configuration Guide Revisions Date November 2013 Revision Initial release

More information

Dell Networking S4048-ON

Dell Networking S4048-ON Dell Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering August 2015 A Dell Deployment and Configuration Guide Revisions Date August 2015 Description Initial

More information

Dell EMC Ready Stack: VMware IaaS on PowerEdge MX Servers and PowerMax Storage

Dell EMC Ready Stack: VMware IaaS on PowerEdge MX Servers and PowerMax Storage Dell EMC Ready Stack: VMware IaaS on PowerEdge MX Servers and PowerMax Storage February 2019 H17534 Abstract This deployment guide describes the requirements, configuration, and deployment of a converged

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes the steps required to deploy a Microsoft Exchange Server 2013 solution on

More information

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME) Dell EMC Engineering February 2018 A Dell EMC Technical White Paper Revisions Date August 2017

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7 and Microsoft Hyper-V for up to 2,000 Virtual Desktops Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract

More information

Dell EMC Ready System for VDI on XC Series

Dell EMC Ready System for VDI on XC Series Dell EMC Ready System for VDI on XC Series Citrix XenDesktop for Dell EMC XC Series Hyperconverged Appliance March 2018 H16969 Deployment Guide Abstract This deployment guide provides instructions for

More information

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information... Installation Checklist HP ProLiant Cluster F500 for Enterprise Virtual Array 4000/6000/8000 using Microsoft Windows Server 2003, Enterprise Edition Stretch Cluster May 2005 Table of Contents ProLiant Cluster

More information

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 6.0 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Data Protection EMC VSPEX Abstract This describes

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes

More information

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide.   support.dell.com VMware Infrastructure 3.0.2 Update 1 for Dell PowerEdge Systems Deployment Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740 Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740 A performance study of 14 th generation Dell EMC PowerEdge servers for Microsoft SQL Server Dell EMC Engineering September

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

Storage Manager 2018 R1. Installation Guide

Storage Manager 2018 R1. Installation Guide Storage Manager 2018 R1 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide.   support.dell.com VMware Infrastructure 3.0.2 Update 1 for Dell Systems Deployment Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your

More information

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

Dell EMC SC Series Storage and SMI-S Integration with Microsoft SCVMM

Dell EMC SC Series Storage and SMI-S Integration with Microsoft SCVMM Dell EMC SC Series Storage and SMI-S Integration with Microsoft SCVMM Dell EMC Engineering February 2017 A Dell EMC Deployment and Configuration Guide Revisions Date May 2012 February 2013 December 2013

More information

Installing VMware vsphere 5.1 Components

Installing VMware vsphere 5.1 Components Installing VMware vsphere 5.1 Components Module 14 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

Dell Networking S3048-ON

Dell Networking S3048-ON Dell Networking S3048-ON Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering July 2015 A Dell Deployment and Configuration Guide Revisions Date July 2015 Description Initial release

More information

Surveillance Dell EMC Storage with FLIR Latitude

Surveillance Dell EMC Storage with FLIR Latitude Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information

More information

Microsoft Windows Server 2016 for Dell EMC PowerEdge Systems. Important Information Guide

Microsoft Windows Server 2016 for Dell EMC PowerEdge Systems. Important Information Guide Microsoft Windows Server 2016 for Dell EMC PowerEdge Systems Important Information Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Citrix XenServer with Dell SC Series Storage Configuration and Deployment

Citrix XenServer with Dell SC Series Storage Configuration and Deployment Citrix XenServer with Dell SC Series Storage Configuration and Deployment Dell Storage Engineering January 2017 A Dell EMC Deployment and Configuration Guide Revisions Date January 2016 Description Initial

More information

Implementing SharePoint Server 2010 on Dell vstart Solution

Implementing SharePoint Server 2010 on Dell vstart Solution Implementing SharePoint Server 2010 on Dell vstart Solution A Reference Architecture for a 3500 concurrent users SharePoint Server 2010 farm on vstart 100 Hyper-V Solution. Dell Global Solutions Engineering

More information

iscsi Boot from SAN with Dell PS Series

iscsi Boot from SAN with Dell PS Series iscsi Boot from SAN with Dell PS Series For Dell PowerEdge 13th generation servers Dell Storage Engineering September 2016 A Dell Best Practices Guide Revisions Date November 2012 September 2016 Description

More information

ECDS MDE 100XVB Installation Guide on ISR G2 UCS-E and VMWare vsphere Hypervisor (ESXi)

ECDS MDE 100XVB Installation Guide on ISR G2 UCS-E and VMWare vsphere Hypervisor (ESXi) ECDS MDE 100XVB Installation Guide on ISR G2 UCS-E and VMWare vsphere Hypervisor (ESXi) Revised: November, 2013 Contents Overview, page 1 Guidelines and Limitations, page 1 Prerequisites, page 2 Installation

More information

Dell EMC SAN Storage with Video Management Systems

Dell EMC SAN Storage with Video Management Systems Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE Design Guide APRIL 2017 1 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

Dell EMC Microsoft Storage Spaces Direct Ready Nodes for VDI

Dell EMC Microsoft Storage Spaces Direct Ready Nodes for VDI Dell EMC Microsoft Storage Spaces Direct Ready Nodes for VDI Microsoft Remote Desktop Services for Dell EMC Microsoft Storage Spaces Direct Ready Nodes May 2018 H17099 Deployment Guide Abstract This deployment

More information

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing & Configuring a SQL JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5

Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 Title: Getting Started with ESX Server 3i Embedded Revision: 20071022 Item: VMW-ENG-Q407-430 You can

More information

Reference Architecture - Microsoft SharePoint Server 2013 on Dell PowerEdge R630

Reference Architecture - Microsoft SharePoint Server 2013 on Dell PowerEdge R630 Reference Architecture - Microsoft SharePoint Server 2013 on Dell PowerEdge R630 A Dell reference architecture for 5000 Users Dell Global Solutions Engineering June 2015 A Dell Reference Architecture THIS

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

EMC CLARiiON CX3 Series FCP

EMC CLARiiON CX3 Series FCP EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2008

More information

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Cisco VDS Service Broker Software Installation Guide for UCS Platforms Cisco VDS Service Broker 1.0.1 Software Installation Guide for UCS Platforms Revised: May 2013 This document provides detailed instructions for installing the Cisco Videoscape Distribution Suite Service

More information

Surveillance Dell EMC Storage with Digifort Enterprise

Surveillance Dell EMC Storage with Digifort Enterprise Surveillance Dell EMC Storage with Digifort Enterprise Configuration Guide H15230 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published August 2016 Dell believes the

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE VSAN INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE VSAN INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE VSAN INFRASTRUCTURE Design Guide APRIL 2017 1 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

Dell EMC Networking S4148-ON and S4128-ON

Dell EMC Networking S4148-ON and S4128-ON Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs Abstract This document illustrates how to configure Dell EMC Networking S4148-ON and S4128-ON switches for use

More information

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018 One Stop Virtualization Shop StarWind Virtual SAN HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2 MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the

More information

Personal vdisk Implementation Guide. Worldwide Technical Readiness

Personal vdisk Implementation Guide. Worldwide Technical Readiness Worldwide Technical Readiness Table of Contents Table of Contents... 2 Overview... 3 Implementation Guide... 4 Pre-requisites... 5 Preparing PVS vdisk to be used with Personal vdisk... 6 Creating a Desktop

More information

Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110

Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110 Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110 A Dell EqualLogic Reference Architecture Dell Storage Engineering July 2013 2013 Dell Inc. All Rights Reserved. Dell,

More information

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 DECEMBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software

More information

Reference Architecture

Reference Architecture EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com

More information

Dell Active Fabric Manager for Microsoft Cloud Platform System 2.2(0.0)

Dell Active Fabric Manager for Microsoft Cloud Platform System 2.2(0.0) Rev. A06 2017-04 Dell Active Fabric Manager for Microsoft Cloud Platform System 2.2(0.0) This document describes the new features, enhancements, and fixed issues for Active Fabric Manager for Microsoft

More information

VMware Infrastructure 3.5 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure 3.5 for Dell PowerEdge Systems. Deployment Guide.   support.dell.com VMware Infrastructure 3.5 for Dell PowerEdge Systems Deployment Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell Flexible Computing Solutions: Deploying On-Demand Desktop Streaming

Dell Flexible Computing Solutions: Deploying On-Demand Desktop Streaming Dell Flexible Computing Solutions: Deploying On-Demand Desktop Streaming Product Group November 2007 Dell White Paper November 2007 Contents Introduction... 3 Overview... 4 Planning the Deployment... 5

More information

Microsoft SharePoint Server 2010 on Dell Systems

Microsoft SharePoint Server 2010 on Dell Systems Microsoft SharePoint Server 2010 on Dell Systems Solutions for up to 10,000 users This document is for informational purposes only. Dell reserves the right to make changes without further notice to any

More information

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN A Dell EqualLogic best practices technical white paper Storage Infrastructure and Solutions Engineering Dell Product Group November 2012 2012

More information

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays Dell EMC Engineering December 2016 A Dell Best Practices Guide Revisions Date March 2011 Description Initial

More information

Dell EMC Microsoft Storage Spaces Direct Ready Node

Dell EMC Microsoft Storage Spaces Direct Ready Node Dell EMC Microsoft Storage Spaces Direct Ready Node Deployment Guide for scalable hyper-converged infrastructure with PowerEdge R440, R740xd and R640 Storage Spaces Direct Ready Nodes Notes, cautions,

More information

Active System Manager Version 8.0 User s Guide

Active System Manager Version 8.0 User s Guide Active System Manager Version 8.0 User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

DSI Optimized Backup & Deduplication for VTL Installation & User Guide DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:

More information

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN of HyperConverged 2 Nodes with Hyper-V Cluster AUGUST 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and

More information

Cisco vwlc on Microsoft Hyper-V Deployment Guide

Cisco vwlc on Microsoft Hyper-V Deployment Guide Cisco vwlc on Microsoft Hyper-V Deployment Guide Introduction 2 Advantages of the vwlc 2 Hardware Requirement 2 Download Cisco Virtual Wireless LAN Controller 2 Prerequisite 5 HYPER-V Requirement 5 Product

More information

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE Reference Architecture EMC STORAGE FOR MILESTONE XPROTECT CORPORATE Milestone multitier video surveillance storage architectures Design guidelines for Live Database and Archive Database video storage EMC

More information

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture. Deploying VMware View in the Enterprise EMC Celerra NS-120 EMC NAS Product Validation Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2009 EMC Corporation.

More information

Creating a 2 node virtual SQL Server 2008 Cluster Configuration Using Windows 2003 MSCS

Creating a 2 node virtual SQL Server 2008 Cluster Configuration Using Windows 2003 MSCS Creating a 2 node virtual SQL Server 2008 Cluster Configuration Using Windows 2003 MSCS Reference No: Date: 10/08/2010 File Name: Creating a 2 node SQL Server 2008 Cluster Configuration using Windows 2003

More information

Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA

Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA Design Guide Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA VMware vsphere 5.1 for up to 2000 Virtual Desktops EMC VSPEX Abstract This guide describes required components and a configuration

More information

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Configuration Guide H14001 REV 1.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2015 Dell believes

More information

PROFITstar & PROFITability Release Hardware Sizing Recommendations For Optimal Performance

PROFITstar & PROFITability Release Hardware Sizing Recommendations For Optimal Performance PROFITstar & PROFITability Hardware Sizing Recommendations For Optimal Performance Navigating the Hardware Sizing Process FAQs... 1 How Do We Know If We Should Upgrade Our Hardware?... 1 We Want to Upgrade

More information

Quest VROOM Quick Setup Guide for Quest Rapid Recovery for Windows and Quest Foglight vapp Installers

Quest VROOM Quick Setup Guide for Quest Rapid Recovery for Windows and Quest Foglight vapp Installers Quest VROOM Quick Setup Guide for Quest Rapid Recovery for Windows and Quest Foglight vapp Installers INTRODUCTION Setup of Quest VROOM requires installation of Rapid Recovery and Foglight for Virtualization

More information

Dell R740 Backup Solution Deployment Guide

Dell R740 Backup Solution Deployment Guide Dell R740 Backup Solution Deployment Guide April 2018 A Dell EMC Backup Document Table of contents 1 Server/Environment Introduction... 3 1.1 Dell PowerEdge 740 Overview... 3 1.2 Configuration Details...

More information

Virtual Appliance User s Guide

Virtual Appliance User s Guide Cast Iron Integration Appliance Virtual Appliance User s Guide Version 4.5 July 2009 Cast Iron Virtual Appliance User s Guide Version 4.5 July 2009 Copyright 2009 Cast Iron Systems. All rights reserved.

More information

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure Generational Comparison Study of Microsoft SQL Server Dell Engineering February 2017 Revisions Date Description February 2017 Version 1.0

More information

Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center

Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center Dell Compellent Solution Guide Kris Piepho, Microsoft Product Specialist October, 2013 Revisions Date Description 1/4/2013

More information

Dell Storage Manager 2016 R3 Installation Guide

Dell Storage Manager 2016 R3 Installation Guide Dell Storage Manager 2016 R3 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

Dell EMC Networking S4148-ON and S4128-ON

Dell EMC Networking S4148-ON and S4128-ON Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs Abstract This document illustrates how to configure Dell EMC Networking S4148-ON and S4128-ON switches for

More information

Dell Storage with Microsoft Storage Spaces Deployment Guide

Dell Storage with Microsoft Storage Spaces Deployment Guide Dell Storage with Microsoft Storage Spaces Deployment Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the product described herein without notice. Before installing and using the product, please review the readme files,

More information

A Principled Technologies deployment guide commissioned by QLogic Corporation

A Principled Technologies deployment guide commissioned by QLogic Corporation A Principled Technologies deployment guide commissioned by QLogic Corporation Table of contents Executive summary... 2 Introduction... 2 QLogic QConvergeConsole... 3 Overview of the procedure... 4 Initial

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 3 Virtual Machine Resource and Performance Checks,

More information

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode) Dell Networking Solutions Engineering July 2011 A Dell EMC Deployment and Configuration Guide Revisions Date Description

More information

Consolidating Microsoft SQL Server databases on PowerEdge R930 server

Consolidating Microsoft SQL Server databases on PowerEdge R930 server Consolidating Microsoft SQL Server databases on PowerEdge R930 server This white paper showcases PowerEdge R930 computing capabilities in consolidating SQL Server OLTP databases in a virtual environment.

More information