Rexroth IndraMotion MTX Software Installation

Size: px
Start display at page:

Download "Rexroth IndraMotion MTX Software Installation"

Transcription

1 Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MTX Software Installation R Edition 02 Installation Instruction

2 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Title Type of Documentation Document Typecode Internal File Reference Purpose of Documentation Record of Revision Rexroth IndraMotion MTX Software Installation Installation Instruction DOK-MTX***-SOFTINS*V07-IB02-EN-P RS-c6ed8c5dbb31e7aa0a6846a001c4b6fd-2-en-US-5 This documentation describes the installation and updating of the Rexroth IndraMotion MTX NC control and the network settings. Edition Release Date Notes B354-01/EN First edition for 07VRS B354-02/EN Changes implemented Copyright Validity Published by Note 2006 Bosch Rexroth AG Copying this document, giving it to others and the use or communication of the contents thereof without express authourity, are forbidden. Offenders are liable for the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design (DIN 34-1). The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract. All rights are reserved with respect to the content of this documentation and the availability of the product. Bosch Rexroth AG Bgm.-Dr.-Nebel-Str Lohr a. Main, Germany Phone +49 (0)93 52/ 40-0 Fax +49 (0)93 52/ Dept. for System Development Machine Tools, E. Wirthmann (EgWi/MePe) This document has been printed on chlorine-free bleached paper.

3 Installation Instruction Rexroth IndraMotion MTX Electric Drives Table of Contents Bosch Rexroth AG I/IV Table of Contents 1 General Information About Setup The Setup Program and this Documentation System Requirements Control Modules IndraControl P40 and IndraControl P Brief Description... 1 Performance data Industrial PCs... 2 General... 2 Overview of Industrial PCs... 2 Documentation references Third-Party PCs... 3 Hardware Requirements for Rexroth IndraMotion MTX... 3 Hardware requirements for Rexroth IndraWorks simulation Software Requirements... 3 Software Requirements for Rexroth IndraMotion MTX... 3 Software requirements for Rexroth IndraWorks simulation Before You Start Installing the User Interface Using Virus Scanners Important Instructions for Use Appropriate Use Introduction Areas of Use and Application Inappropriate Use... 6 Page 3 Safety Instructions for Electric Drives Safety Instructions - General Information Using the Safety Instructions and Passing them on to Others How to Employ the Safety Instructions Explanation of Warning Symbols and Degrees of Hazard Seriousness Hazards by Improper Use Instructions with Regard to Specific Dangers Protection Against Contact with Electrical Parts and Housings Protection Against Electric Shock by Protective Extra-Low Voltage Protection Against Dangerous Movements Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting Protection Against Contact with Hot Parts Protection During Handling and Mounting Battery Safety Protection Against Pressurized Systems Carrying Out Installation Administrator Privileges... 17

4 II/IV Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Table of Contents Page General Access Data Log in as Administrator Initial Installation of Rexroth IndraWorks CD-ROM General Local CD-ROM Drive CD-ROM Drive in a Network Installation from Hard Disk Installing Rexroth IndraWorks Installation of System Variant IndraControl L40 (Emulation) Further Steps Before Commissioning an MTX Control Firewall Settings Windows Firewall NFS Server and TeleBugger IndraControl P40/IndraControl P Update Network Driver Firmware Download Parallel Installation Uninstallationof Rexroth IndraWorks Data Archival/Backup Archiving the IndraWorks Project Archiving of Data that are Not Project-Specific Firmware Download Executing a Software Update of IndraWorks Executing an Update of IndraWorks Restoring Data Restoring Data That Are Not Project-Specific Restoring the IndraWorks Project IndraControl P60/P General Introduction Overview General Display of the Startup Phase General Status Information Status Line Tool Bars Main Menu... 44

5 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG III/IV Table of Contents Page Main Menu Startup Startup Mode Data Backup Archive Function Firmware Download Incorporating File Systems (Mount) General Using the Dialog Box Using the USB Stick on the MTX as the Mount Directory General Configuration MTX Boot Parameter NFS Parameters Carrying Out an MTX Soft Reset (SR) Ethernet Interface Boot Parameters User Level Contextual Menu Call Parameters IP Address Overview Configuration of Communication Interface General Setting the IP Address Network Adapter Setting IP Address of IndraControl P60/P40 Plug-in Card Ethernet Connection of Basic PC Device Order of Network Connections Network Settings General Information Enabling a CD Drive in a Network Connecting to a Network Enabled in the CD-ROM Drive Access to the IndraControl P60/P40 from an External PC (Routing) Overview Conditions Entering a Route IndraControl L MTX Compact Firmware Download using IW Engineering Desktop Incorporating File Systems (Mount) Operator Panel Handling / MTX Compact Status Display Additional information Start Settings of Windows XP General... 77

6 IV/IV Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Table of Contents Page Switching off the Windows Logo Autologin Windows XP IndraWorks Operation Autostart Windows XP User privileges Introduction Definition of Terms Setting up an XP User Enabling Required Privileges Enabling Files/Directories Tips and Additional Notes Version Display Calling the Version Display Showing the Version Display Version Information for MTX System Version Information of MTX Interface Components Version Information of MTX NC Kernel Components Version Information about LDX Component Protection from Access by External PCs, Protection against Viruses Operating Virus Scanners in Conjunction with the Bosch Rexroth MTX Control System General Performance of the System as a Whole Proposals for Configuring Virus Scanner Software Operating a Firewall in Conjunction with the Bosch Rexroth MTX Control System General Performance of the System as a Whole Configuration Proposals Service & Support Helpdesk Service Hotline Internet Helpful Information Index... 95

7 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 1/96 General Information About Setup 1 General Information About Setup 1.1 The Setup Program and this Documentation What is installed? Who installs the program? The setup program installs the Rexroth IndraMotion MTX user interface. Installing the user interface requires experience in working with PCs and with the operating system. Administrator privileges are required for installation. Setup may be executed only by an experienced user with knowledge of operating systems and with administrator privileges. Setup program Documentation The setup program decompresses and installs the user interface and the associated files from the CD-ROM onto your hard disk. The user interface cannot be operated without this installation. Furthermore, it is possible to update and uninstall the software. This documentation informs you about how to install and set up the user interface on your hard disk, how to execute an update and how to remove the user interface. 1.2 System Requirements Read these installation instructions and, if necessary, additional documents before you install the software Control Modules IndraControl P40 and IndraControl P60 Brief Description Performance data As a scalable system, the Rexroth IndraMotion MTX control system currently consists of three system variants: IndraMotion MTX compact, based on the IndraControl L40 control module IndraMotion MTX standard, based on the IndraControl P40 control module IndraMotion MTX performance, based on the IndraControl P60 control module All the control modules provide both CNC and PLC functions. The highest configuration provides CNC performance allowing activation of up to 64 axes in 12 independent CNC processing channels. The standard equipment of the control modules includes interfaces allowing the activation of I/Os via PROFIBUS-DP, of intelligent drives via the SERCOS interface and of peripheral assemblies via Ethernet. A high-speed interface permits the module to be supplemented by additional field buses or interfaces. The IndraControl L40 control module in terminal format has been designed on a switch cabinet for top hat rail assembly. The control modules IndraControl P40 and IndraControl P60 are executed as PCI slot modules and will be used in a free slot of an industrial PC. Designation IndraControl L40 IndraControl P40 IndraControl P60 Number of axes max. 8 max. 8 max. 64 thereof spindles max. 2 max. 2 max. 8 Number of interpolated axes/ channel max. 4 max. 4 max. 8

8 2/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction General Information About Setup Designation IndraControl L40 IndraControl P40 IndraControl P60 Number of NC channels max. 2 max. 2 max. 12 SERCOS cycle time min. 6 ms (for 8-axis configuration, 4-axis interpolation) min. 6 ms (for 8-axis configuration, 4-axis interpolation) Block cycle time min. 6 ms min. 6 ms min. 250 µs min. 250 µs (for 8-axis configuration, 4-axis interpolation) Industrial PCs General Overview of Industrial PCs Fig.1-1: Power data, IndraControl L40, P40, P60 Plug-in cards IndraControl P40 and IndraControl P60 are inserted into a free PCI slot in Bosch Rexroth standard industrial PCs and high-end industrial PCs, as well as in third-party PCs. Documentation references Fig.1-2: Overview of industrial PCs Documentation Type Material number Rexroth IndraControl VSP 16.1/40.1 DOK-SUPPL*-VSP*16/40**-PRxx-EN-P R Rexroth IndraControl VDP 16.1/40.1/60.1 DOK-SUPPL*-VDP16/40/60-PRxx-EN-P R Rexroth IndraControl VPP 16.1/40.1/60.1 DOK-SUPPL*-VPP*XX.1***-PRxx-EN-P R Rexroth VSB 40.1 DOK-SUPPL*-VSB*40.1***-PRxx-EN-P R Rexroth IndraControl L40 DOK-CONTRL-IC*L40*****-PRxx-EN-P R Rexroth VAM 11.1/41.1 DOK-SUPPL*-VAM*11/41**-PRxx-EN-P R Rexroth VAM 10.1/40.1 DOK-SUPPL*-VAM*10/40**-PRxx-EN-P R Rexroth VAK 10.1/40.1 DOK-SUPPL*-VAK*40.1***-PRxx-EN-P R

9 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 3/96 General Information About Setup Documentation Type Material number Rexroth VAK 11/41 DOK-SUPPL*-VAK*11/41**-PRxx-EN-P R Rexroth RECO Inline, PROFIBUS-DP DOK-CONTRL-R-IL*PBSSYS-AWxx-EN-P R Rexroth RECO Inline, PROFIBUS-DP Terminal and Module Power Supply Rexroth RECO Inline, Digital Input/Output Terminals DOK-CONTRL-R-IL*PB*-BK-FKxx-EN-P DOK-CONTRL-R-IL*DIO***-FKxx-EN-P R R Rexroth Fieldline, PROFIBUS Devices DOK-CONTRL-RF-FLS-PB**-PRxx-EN-P R Third-Party PCs Fig.1-3: Documentation references Hardware Requirements for Rexroth IndraMotion MTX The following hardware requirements apply for using Rexroth IndraMotion MTX on third-party PCs: IBM-compatible PC, Pentium III or later CPU clock frequency: 933 MHz Main memory: 512 MB Graphics resolution 800x600 pixels Color depth: 16 bits Hardware requirements for Rexroth IndraWorks simulation The following hardware requirements apply for simulating Rexroth IndraWorks on third-party PCs: IBM-compatible PC CPU clock frequency: 966 MHz Main memory: 512 MB Graphics resolution Software Requirements 800x600 pixels Color depth: 16 bits Software Requirements for Rexroth IndraMotion MTX Microsoft Windows XP Professional with Service Pack 2 is required to operate Rexroth IndraMotion MTX. Software requirements for Rexroth IndraWorks simulation The following software requirements apply for simulating Rexroth IndraWorks: Microsoft Windows XP Professional with Service Pack 2 Microsoft Windows 2000 with Service Pack 4 (not supported by all components) Microsoft Windows Server 2003 (not supported by all components)

10 4/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction General Information About Setup 1.3 Before You Start Installing the User Interface If you have ordered a completely configured operator terminal with control modules, the user interface and the related firmware are already installed when the unit is delivered. For user access, the following values are preset (depending on the operating system): Windows XP access: User name: Rexroth Password: Rexroth User interface: User name: Admin Password: Admin 1.4 Using Virus Scanners For the preinstalled operator terminal, you need the following chapters only for updating the software. The user interface must be installed according to the following description if you use the operator terminal or a third-party PC with external control hardware or if you want to use the IndraControl P40/P60 control module on a third-party PC. During the Rexroth IndraMotion MTX system installation, Java scripts are used for special tasks (embedded setups such as.net Framework ServicePatch, IndraLogic, WinStudio). These are executed by MsiExex.exe. Some virus scanners, such as Norton Antivirus, see this as possible virus activity and issue a corresponding message. If such a message appears, it can be ignored.

11 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 5/96 Important Instructions for Use 2 Important Instructions for Use 2.1 Appropriate Use Introduction Areas of Use and Application Bosch Rexroth products represent state-of-the-art developments and manufacturing. They are tested prior to delivery to ensure operating safety and reliability. The products may only be used in the manner that is defined as appropriate. If they are used in an inappropriate manner, then situations can develop that may lead to property damage or injury of personnel. Bosch Rexroth, as manufacturer, is not liable for any damages resulting from inappropriate use. In such cases, the guarantee and the right to payment of damages resulting from inappropriate use are forefeited. The user alone carries all responsibility of the risks. Before using Bosch Rexroth products, make sure that all the pre-requisites for appropriate use of the products are satisfied: Personnel that in a way, shape or form uses our products must first read and understand the relevant safety instructions and be familiar with appropriate use. If the product takes the form of hardware, then they must remain in the original state, in other words, no structural changes are permitted. It its not permitted to decompile software products or alter source codes. Do not mount damaged or faulty products or use them in operation. Make sure that the products have been installed in the manner described in the relevant documentation. The Rexroth IndraMotion MTX control is used to Programming contour and machining technology (feedrate, spindle speed, tool change) or a workpiece. Guiding a machining tool along a programmed bath. Feed drives, spindles and auxiliary axes of a machine tool are activated via SERCOS interface. This additionally requires I/O components for the integrated PLC which, in combination with the actual CNC, controls the machining process as a whole and also monitors this process with regard to technical safety. The unit may be operated only with the explicitly specified hardware component configurations and combinations and only with the software and firmware specified in the appropriate documentations and functional descriptions. The Rexroth IndraMotion MTX has been developed for control tasks in multiaxis installations. Typical applications are: lathes milling machines

12 6/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Important Instructions for Use 2.2 Inappropriate Use machining centers Using the Rexroth IndraMotion MTX outside of the above-referenced areas of application or under operating conditions other than described in the document and the technical data specified is defined as "inappropriate use". The Rexroth IndraMotion MTX may not be used if they are subject to operating conditions that do not meet the above specified ambient conditions. This includes, for example, operation under water, in the case of extreme temperature fluctuations or extreme maximum temperatures or if Bosch Rexroth has not specifically released Rexroth IndraMotion MTX for that intended purpose. Please note the specifications outlined in the general safety instructions!

13 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 7/96 Safety Instructions for Electric Drives 3 Safety Instructions for Electric Drives 3.1 Safety Instructions - General Information Using the Safety Instructions and Passing them on to Others Do not attempt to install or commission this device without first reading all documentation provided with the product. Read and understand these safety instructions and all user documentation prior to working with the device. If you do not have the user documentation for the device, contact your responsible Bosch Rexroth sales representative. Ask for these documents to be sent immediately to the person or persons responsible for the safe operation of the device. If the device is resold, rented and/or passed on to others in any other form, these safety instructions must be delivered with the device in the official language of the user's country. WARNING Improper use of these devices, failure to follow the safety instructions in this document or tampering with the product, including disabling of safety devices, may result in material damage, bodily harm, electric shock or even death! Observe the safety instructions! How to Employ the Safety Instructions Read these instructions before initial commissioning of the equipment in order to eliminate the risk of bodily harm and/or material damage. Follow these safety instructions at all times. Bosch Rexroth AG is not liable for damages resulting from failure to observe the warnings provided in this documentation. Read the operating, maintenance and safety instructions in your language before commissioning the machine. If you find that you cannot completely understand the documentation for your product, please ask your supplier to clarify. Proper and correct transport, storage, assembly and installation, as well as care in operation and maintenance, are prerequisites for optimal and safe operation of this device. Only assign trained and qualified persons to work with electrical installations: Only persons who are trained and qualified for the use and operation of the device may work on this device or within its proximity. The persons are qualified if they have sufficient knowledge of the assembly, installation and operation of the product, as well as an understanding of all warnings and precautionary measures noted in these instructions. Furthermore, they must be trained, instructed and qualified to switch electrical circuits and devices on and off in accordance with technical safety regulations, to ground them and to mark them according to the requirements of safe work practices. They must have adequate safety equipment and be trained in first aid. Only use spare parts and accessories approved by the manufacturer.

14 8/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Safety Instructions for Electric Drives Follow all safety regulations and requirements for the specific application as practiced in the country of use. The devices have been designed for installation in industrial machinery. The ambient conditions given in the product documentation must be observed. Only use safety-relevant applications that are clearly and explicitly approved in the Project Planning Manual. If this is not the case, they are excluded. Safety-relevant are all such applications which can cause danger to persons and material damage. The information given in the documentation of the product with regard to the use of the delivered components contains only examples of applications and suggestions. The machine and installation manufacturer must make sure that the delivered components are suited for his individual application and check the information given in this documentation with regard to the use of the components, make sure that his application complies with the applicable safety regulations and standards and carry out the required measures, modifications and complements. Commissioning of the delivered components is only permitted once it is sure that the machine or installation in which they are installed complies with the national regulations, safety specifications and standards of the application. Operation is only permitted if the national EMC regulations for the application are met. The instructions for installation in accordance with EMC requirements can be found in the section on EMC in the respective documentation (Project Planning Manuals of components and system). The machine or installation manufacturer is responsible for compliance with the limiting values as prescribed in the national regulations. Technical data, connection and installation conditions are specified in the product documentation and must be followed at all times. National regulations which the user must take into account European countries: according to European EN standards United States of America (USA): National Electrical Code (NEC) National Electrical Manufacturers Association (NEMA), as well as local engineering regulations regulations of the National Fire Protection Association (NFPA) Canada: Canadian Standards Association (CSA) Other countries: International Organization for Standardization (ISO) International Electrotechnical Commission (IEC) Explanation of Warning Symbols and Degrees of Hazard Seriousness The safety instructions describe the following degrees of hazard seriousness. The degree of hazard seriousness informs about the consequences resulting from non-compliance with the safety instructions:

15 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 9/96 Safety Instructions for Electric Drives Warning symbol Signal word Danger Degree of hazard seriousness acc. to ANSI Z Death or severe bodily harm will occur. Warning Caution Death or severe bodily harm may occur. Minor or moderate bodily harm or material damage may occur. Fig.3-1: Hazard classification (according to ANSI Z 535) Hazards by Improper Use DANGER High electric voltage and high working current! Risk of death or severe bodily injury by electric shock! Observe the safety instructions! DANGER Dangerous movements! Danger to life, severe bodily harm or material damage by unintentional motor movements! Observe the safety instructions! WARNING High electric voltage because of incorrect connection! Risk of death or bodily injury by electric shock! Observe the safety instructions! WARNING Health hazard for persons with heart pacemakers, metal implants and hearing aids in proximity to electrical equipment! Observe the safety instructions! Hot surfaces on device housing! Danger of injury! Danger of burns! Observe the safety instructions! CAUTION CAUTION Risk of injury by improper handling! Risk of bodily injury by bruising, shearing, cutting, hitting or improper handling of pressurized lines! Observe the safety instructions!

16 10/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Safety Instructions for Electric Drives CAUTION Risk of injury by improper handling of batteries! Observe the safety instructions! 3.2 Instructions with Regard to Specific Dangers Protection Against Contact with Electrical Parts and Housings This section concerns devices and drive components with voltages of more than 50 Volt. Contact with parts conducting voltages above 50 Volts can cause personal danger and electric shock. When operating electrical equipment, it is unavoidable that some parts of the devices conduct dangerous voltage. DANGER High electrical voltage! Danger to life, electric shock and severe bodily injury! Only those trained and qualified to work with or on electrical equipment are permitted to operate, maintain and repair this equipment. Follow general construction and safety regulations when working on power installations. Before switching on the device, the equipment grounding conductor must have been non-detachably connected to all electrical equipment in accordance with the connection diagram. Do not operate electrical equipment at any time, even for brief measurements or tests, if the equipment grounding conductor is not permanently connected to the mounting points of the components provided for this purpose. Before working with electrical parts with voltage potentials higher than 50 V, the device must be disconnected from the mains voltage or power supply unit. Provide a safeguard to prevent reconnection. With electrical drive and filter components, observe the following: Wait 30 minutes after switching off power to allow capacitors to discharge before beginning to work. Measure the electric voltage on the capacitors before beginning to work to make sure that the equipment is safe to touch. Never touch the electrical connection points of a component while power is turned on. Do not remove or plug in connectors when the component has been powered. Install the covers and guards provided with the equipment properly before switching the device on. Before switching the equipment on, cover and safeguard live parts safely to prevent contact with those parts. A residual-current-operated circuit-breaker or r.c.d. cannot be used for electric drives! Indirect contact must be prevented by other means, for example, by an overcurrent protective device according to the relevant standards. Secure built-in devices from direct touching of electrical parts by providing an external housing, for example a control cabinet.

17 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 11/96 Safety Instructions for Electric Drives For electrical drive and filter components with voltages of more than 50 volts, observe the following additional safety instructions. DANGER High housing voltage and high leakage current! Risk of death or bodily injury by electric shock! Before switching on, the housings of all electrical equipment and motors must be connected or grounded with the equipment grounding conductor to the grounding points. This is also applicable before short tests. The equipment grounding conductor of the electrical equipment and the devices must be non-detachably and permanently connected to the power supply unit at all times. The leakage current is greater than 3.5 ma. Over the total length, use copper wire of a cross section of a minimum of 10 mm 2 for this equipment grounding connection! Before commissioning, also in trial runs, always attach the equipment grounding conductor or connect to the ground wire. Otherwise, high voltages may occur at the housing causing electric shock Protection Against Electric Shock by Protective Extra-Low Voltage Protective extra-low voltage is used to allow connecting devices with basic insulation to extra-low voltage circuits. All connections and terminals with voltages between 5 and 50 volts at Rexroth products are PELV systems. 1) It is therefore allowed to connect devices equipped with basic insulation (such as programming devices, PCs, notebooks, display units) to these connections and terminals. WARNING High electric voltage by incorrect connection! Risk of death or bodily injury by electric shock! If extra-low voltage circuits of devices containing voltages and circuits of more than 50 volts (e.g. the mains connection) are connected to Rexroth products, the connected extra-low voltage circuits must comply with the requirements for PELV. 2) Protection Against Dangerous Movements Dangerous movements can be caused by faulty control of connected motors. Some common examples are: improper or wrong wiring of cable connections incorrect operation of the equipment components wrong input of parameters before operation malfunction of sensors, encoders and monitoring devices defective components software or firmware errors Dangerous movements can occur immediately after equipment is switched on or even after an unspecified time of trouble-free operation. 1) "Protective Extra-Low Voltage" 2) "Protective Extra-Low Voltage"

18 12/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Safety Instructions for Electric Drives The monitoring in the drive components will normally be sufficient to avoid faulty operation in the connected drives. Regarding personal safety, especially the danger of bodily harm and material damage, this alone cannot be relied upon to ensure complete safety. Until the integrated monitoring functions become effective, it must be assumed in any case that faulty drive movements will occur. The extent of faulty drive movements depends upon the type of control and the state of operation.

19 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 13/96 Safety Instructions for Electric Drives DANGER Dangerous movements! Danger to life, risk of injury, severe bodily harm or material damage! Ensure personal safety by means of qualified and tested higher-level monitoring devices or measures integrated in the installation. These measures have to be provided for by the user according to the specific conditions within the installation and a hazard and fault analysis. The safety regulations applicable for the installation have to be taken into consideration. Unintended machine motion or other malfunction is possible if safety devices are disabled, bypassed or not activated. To avoid accidents, bodily harm and/or material damage: Keep free and clear of the machine s range of motion and moving parts. Possible measures to prevent people from accidentally entering the machine s range of motion: use safety fences use safety guards use protective coverings install light curtains or light barriers Fences and coverings must be strong enough to resist maximum possible momentum. Mount the emergency stop switch in the immediate reach of the operator. Verify that the emergency stop works before startup. Don t operate the device if the emergency stop is not working. Isolate the drive power connection by means of an emergency stop circuit or use a safety related starting lockout to prevent unintentional start. Make sure that the drives are brought to a safe standstill before accessing or entering the danger zone. Additionally secure vertical axes against falling or dropping after switching off the motor power by, for example: mechanically securing the vertical axes, adding an external braking/ arrester/ clamping mechanism or ensuring sufficient equilibration of the vertical axes. The standard equipment motor brake or an external brake controlled directly by the drive controller are not sufficient to guarantee personal safety! Disconnect electrical power to the equipment using a master switch and secure the switch against reconnection for: maintenance and repair work cleaning of equipment long periods of discontinued equipment use Prevent the operation of high-frequency, remote control and radio equipment near electronics circuits and supply leads. If the use of such devices cannot be avoided, verify the system and the installation for possible malfunctions in all possible positions of normal use before initial startup. If necessary, perform a special electromagnetic compatibility (EMC) test on the installation.

20 14/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Safety Instructions for Electric Drives Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting Magnetic and electromagnetic fields generated by current-carrying conductors and permanent magnets in motors represent a serious personal danger to those with heart pacemakers, metal implants and hearing aids. WARNING Health hazard for persons with heart pacemakers, metal implants and hearing aids in proximity to electrical equipment! Persons with heart pacemakers and metal implants are not permitted to enter following areas: Areas in which electrical equipment and parts are mounted, being operated or commissioned. Areas in which parts of motors with permanent magnets are being stored, repaired or mounted. If it is necessary for somebody with a pacemaker to enter such an area, a doctor must be consulted prior to doing so. The noise immunity of present or future implanted heart pacemakers differs greatly so that no general rules can be given. Those with metal implants or metal pieces, as well as with hearing aids, must consult a doctor before they enter the areas described above. Otherwise health hazards may occur Protection Against Contact with Hot Parts CAUTION Hot surfaces at motor housings, on drive controllers or chokes! Danger of injury! Danger of burns! Do not touch surfaces of device housings and chokes in the proximity of heat sources! Danger of burns! Do not touch housing surfaces of motors! Danger of burns! According to the operating conditions, temperatures can be higher than 60 C, 140 F during or after operation. Before accessing motors after having switched them off, let them cool down for a sufficiently long time. Cooling down can require up to 140 minutes! Roughly estimated, the time required for cooling down is five times the thermal time constant specified in the Technical Data. After switching drive controllers or chokes off, wait 15 minutes to allow them to cool down before touching them. Wear safety gloves or do not work at hot surfaces. For certain applications, the manufacturer of the end product, machine or installation, according to the respective safety regulations, has to take measures to avoid injuries caused by burns in the end application. These measures can be, for example: warnings, guards (shielding or barrier), technical documentation Protection During Handling and Mounting In unfavorable conditions, handling and mounting certain parts and components in an improper way can cause injuries.

21 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 15/96 Safety Instructions for Electric Drives CAUTION Risk of injury by improper handling! Bodily injury by bruising, shearing, cutting, hitting! Observe the general construction and safety regulations on handling and mounting. Use suitable devices for mounting and transport. Avoid jamming and bruising by appropriate measures. Always use suitable tools. Use special tools if specified. Use lifting equipment and tools in the correct manner. If necessary, use suitable protective equipment (for example safety goggles, safety shoes, safety gloves). Do not stand under hanging loads. Immediately clean up any spilled liquids because of the danger of skidding Battery Safety Batteries consist of active chemicals enclosed in a solid housing. Therefore, improper handling can cause injury or material damage. CAUTION Risk of injury by improper handling! Do not attempt to reactivate low batteries by heating or other methods (risk of explosion and cauterization). Do not recharge the batteries as this may cause leakage or explosion. Do not throw batteries into open flames. Do not dismantle batteries. When replacing the battery/batteries do not damage electrical parts installed in the devices. Only use the battery types specified by the manufacturer. Environmental protection and disposal! The batteries contained in the product are considered dangerous goods during land, air, and sea transport (risk of explosion) in the sense of the legal regulations. Dispose of used batteries separate from other waste. Observe the local regulations in the country of assembly Protection Against Pressurized Systems According to the information given in the Project Planning Manuals, motors cooled with liquid and compressed air, as well as drive controllers, can be partially supplied with externally fed, pressurized media, such as compressed air, hydraulics oil, cooling liquids and cooling lubricating agents. Improper handling of the connected supply systems, supply lines or connections can cause injuries or material damage.

22 16/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Safety Instructions for Electric Drives CAUTION Risk of injury by improper handling of pressurized lines! Do not attempt to disconnect, open or cut pressurized lines (risk of explosion). Observe the respective manufacturer's operating instructions. Before dismounting lines, relieve pressure and empty medium. Use suitable protective equipment (for example safety goggles, safety shoes, safety gloves). Immediately clean up any spilled liquids from the floor. Environmental protection and disposal! The agents used to operate the product might not be economically friendly. Dispose of ecologically harmful agents separately from other waste. Observe the local regulations in the country of assembly.

23 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 17/96 Carrying Out Installation 4 Carrying Out Installation 4.1 Administrator Privileges General Access Data Administrator privileges are necessary for making operating system settings and for installing the user interface. Preinstalled operator panels supplied by the manufacturer have the following access data: Windows XP: Log in as Administrator User name: Rexroth Password: Rexroth Log in as administrator: Windows XP: User name: Administrator Password: - (none) 4.2 Initial Installation of Rexroth IndraWorks CD-ROM General Local CD-ROM Drive Internal CD-ROM drive External CD-ROM drive Rexroth IndraWorks software is supplied only on CD-ROM. For this reason, a CD-ROM drive or network connection must be available for setup. Certain Rexroth industrial PCs (e.g. those in a switch cabinet) include a CD- ROM drive. To execute Setup, a portable CD-ROM drive can be connected to the USB port of the industrial PC.

24 18/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation CD-ROM Drive in a Network Fig.4-1: Locally connected CD-ROM drive If the industrial PC is connected to a network, the CD-ROM drive of any PC incorporated in the network can be used for setup (see "Network settings" chapter). 1. Install the Microsoft network. 2. Enable the CD-ROM drive of the connected PC. Fig.4-2: Installation from Hard Disk CD-ROM drive in a network If it is necessary to copy the data carrier (CD1, CD2) to the hard disk and then to install from there, the following must be observed: 1. Create a directory on the hard disk with the name CD1 2. On this level, create another directory with the name CD2 IMPORTANT: The directory names must be CD1 and CD2! 3. Copy the content of the first CD into directory CD1 4. Copy the content of the second CD into directory CD2 5. Start SETUP.EXE from the directory CD1 from the hard disk The installation runs automatically without demanding a CD change.

25 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 19/96 Carrying Out Installation Installing Rexroth IndraWorks In this description, we assume that you use CD-ROM drive "E" for setup. 1. Insert the CD into the CD-ROM drive. 2. Click Execute in the Start menu. 3. Type the letter for the drive together with ":\SETUP.EXE". When you install your system from a CD-ROM, enter, for instance, "E: \SETUP.EXE". Fig.4-3: Windows XP "Run" dialog box 4. Then click OK or confirm with <<Enter>>. This starts the installation wizard. 5. Select the language for the setup program. Fig.4-4: Language selection You are guided through the installation. Press the Next > button to open the next dialog box; pressing < Back brings you back to the previous dialog box. 6. Select the systems that you want to install and press Next >.

26 20/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation Fig.4-5: Selecting the systems to be installed A list of tasks to be executed is shown. Confirm the activities by pressing Next >. 7. A message appears if release notes exist for the current version. If you select "Display Release Notes", the corresponding PDF document opens after you press Next >. Fig.4-6: Message about release notes 8. Exit Acrobat Reader after reading the release notes and heed the remaining setup instructions.

27 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 21/96 Carrying Out Installation 9. Accept the conditions of the license agreement. Fig.4-7: License agreement 10. Confirm by pressing Next >; the "Customer Information" dialog box is displayed. Fig.4-8: Customer information 11. Enter the name and company of the rightful user and press Next >,; this brings you to the selection of the desired setup directory (target folder). 12. In the dialog box, select the drive and the destination folder where the user interface is to be installed.

28 22/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation The hard disk of a standard VPP has two partitions (C: NTFS file system, D: FAT32 file system). The interface must be installed on drive C. Fig.4-9: Selecting the Target Folder When you press the Next > button, the "MTX Additional Configuration" dialog box opens. 13. Input dialog for MTX target name "mtxctrl" is offered as default entry. The MTX target name can have max. 7 characters. Pressing Next > brings you to the IP input dialog box.

29 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 23/96 Carrying Out Installation Fig.4-10: Entering the target name 14. Enter the IP address for the control card. Default: Pressing Next > brings you to the Start dialog box for the actual installation procedure. Fig.4-11: IP address of IndraControl P40/P Start the installation procedure by pressing Install

30 24/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation Fig.4-12: Starting the installation procedure The installation procedure now starts. The progress of installation is displayed in a progress bar. Fig.4-13: Progress of the installation procedure 16. During installation, you are asked to change the CD. 17. When requested, complete the setup by clicking Finish. After completion of the copying process, you will be prompted to restart Windows.

31 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 25/96 Carrying Out Installation Fig.4-14: End of the installation procedure You must restart Windows and/or your computer before you can use the program. After startup, the system files are updated and registrations, if required, are executed. This completes the setup Installation of System Variant IndraControl L40 (Emulation) Rexroth IndraMotion MTX is installed as emulation in connection with Indra Control L40. The installation is executed as described previously. The only difference is that the dialog boxes for entering the target name and the IP address do not appear. 4.3 Further Steps Before Commissioning an MTX Control Firewall Settings Windows Firewall NFS Server and TeleBugger The service "Windows Firewall/ common utilization of internet connection" must not be exited! Otherwise the MTX emulation crashes without an error message after booting the PC. Firewall settings must be made before commissioning. To permit the mounting of directories on third-party computers and to allow remote debugging if errors occur, exceptions must be set for these programs. These programs are "bnfsser.exe" and "TeleBug.exe" in directory...\rexroth\indraworks\mtx\bin. The exceptions are set as follows:

32 26/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation 1. In the Start menu, open Start Settings Control Panels Windows Firewall. 2. Activate tab "Exceptions" and click on "Program...". 3. Click "Browse" and switch to directory "...\Rexroth\IndraWorks\mtx \bin". Fig.4-15: Set "bnfsser.exe" as exception 4. Select file "bnfsser.exe" and open it. 5. Confirm the dialog box by pressing "OK". This transfers the file to the list of exceptions. 6. Use the same procedure for file "TeleBug.exe". This removes these programs from the firewall. IndraControl P40/IndraControl P60 Control card IndraControl P40/P60 must be removed from the firewall manually.

33 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 27/96 Carrying Out Installation 1. In the Start menu, open Start Settings Control Panels Windows Firewall. 2. Select tab "Advanced". Fig.4-16: Update Network Driver Advanced firewall settings 3. Deactivate entry "LAN connection 2" by removing the checkmark. 4. Accept the settings by pressing "OK". This removes the IndraControl P40/P69 from the firewall. The network driver for IndraControl P40/P60 establishes communication between the CPM60 control card and the IPC. The driver for IndraControl P40/ P60 is installed as follows: Open the Windows "Device Manager" via "Start Settings Control Panel System, tab "Hardware". The new hardware "Network adapter" which was detected by Windows should be marked with a yellow exclamation mark in the Device Manager. Click the right mouse button on the network adapter and select menu "Update driver...". The "Hardware update wizard" opens.

34 28/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation Firmware Download 4.4 Parallel Installation Select the option "Install software from a list or certain source" in the hardware update wizard and press "Continue". Then select the option "Find a corresponding driver in this source" in the "Search and installation options" and enter path "LW\Program Files\Rexroth\IndraWorks\MTX\drivers" in "Find also in following sources". Exit the dialog box with "Next". The driver is now installed; after installation, it is entered under Network adapters as "PCC-P Numerical Controller". The control absolutely must be restarted after installation of the network driver. Afterwards, the IP address for the network adapter must be entered. See sections "Network Settings" and "IP Addresses". If the control was started for the first time after installation of the IndraControl P40/P60 control hardware, the "New hardware found" wizard opens automatically (same procedure as described above). After updating the IndraMotion MTX, the network driver should be updated. It is necessary to check if downloading firmware is necessary. The firmware version already installed must be compared with the version to load and, if necessary, the new firmware must be loaded. You can view the currently installed firmware version in the menu of the CMP 60 control under? - Firmware Version. Firmware Download is executed with the CMP 60 control. The control can be opened via Start Program Files Rexroth CMP60 CMP60 Control. Firmware Download can be executed with the menu bar via command Commands - Download. Alternatively, the icon for Firmware Download (topmost icon line, at the extreme left) can be used to call the Download Manager. Select the entry Monitor - Bootloader in the Firmware Download dialog box. The password is "Software". Then exit the dialog by pressing OK. Select the entry "Firmware" in the Firmware Download dialog box. Then exit the dialog box by clicking YES. After a successful download, execute a reset. After the software reset has been triggered, the CMP control starts up and stops at a "red zero". It is possible to install several different versions of the Rexroth IndraWorks software. Proceed as follows if you want to install a version in addition to one you already have. 1. Start installation as described under chapter "Installing Rexroth IndraWorks" on page 19. After the language is selected, a selection dialog box appears.

35 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 29/96 Carrying Out Installation Fig.4-17: Setting the installation type 2. Select "New installation" and close the dialog box by pressing "Next >". This starts the installation. The remaining installation steps are the same as for a new installation. 4.5 Uninstallationof Rexroth IndraWorks Uninstallation Using Operating System Die Deinstallation von Rexroth IndraWorks wird über das Betriebssystem (Aufruf: Start menu - Control panel - Software). Select "IndraWorks" as the program to be uninstalled. The Rexroth IndraWorks installation CDs are not required for this. After uninstallation, you are asked whether ALL the data within the Installation folder are to be moved to the trash. CAUTION Loss of user data! Make sure that you save the user data before uninstalling the software if you want to keep them. Fig.4-18: End of the uninstallation procedure

36 30/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Carrying Out Installation After completion of the uninstallation process, you will be prompted to restart Windows. In order to update the system files, restart Windows and/or your computer. Uninstallation with parallel installations After startup, the system files are updated. This completes the uninstallation process. If several software versions have been installed, uninstallation can also be carried out via Setup. After Setup is started (see chapter "Installing Rexroth IndraWorks" on page 19), a selection dialog box appears. Fig.4-19: Selection dialog box - removing an installation 1. From the list, select the version that you want to remove. 2. Activate the selection "Remove an installation". 3. Press Next > to continue with uninstallation.

37 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 31/96 Data Archival/Backup 5 Data Archival/Backup 5.1 Archiving the IndraWorks Project Archiving the IndraWorks project also includes the archiving of NC data. Start archiving in IndraWorks in Project - Archiving. Select the project to archive (normally the last active project) and press "Continue". Determine the name and path of the archive and press "Continue". Check the details and continue with "Finish" if all settings are correct. MTX archiving is now started. Acknowledge the welcome dialog box with "Continue". Select the portions to be archived and confirm with "Continue". If archive part "Remanent data of PLC" is selected, the PLC should be stopped using the CMP60 control before starting archiving. "Software" is the password to stop the PLC by pressing the "PLC" button. Confirm the information by pressing "Finish". Now the MTX archive is created. Exit the dialog box "Create MTX archive - summary" with "Close". Now the project archive is created. After successful archiving, a dialog box with a summary is displayed. Note: The project path of the archived IndraWorks project, as well as the name and path of the archive, should be noted! This information is necessary for subsequent restoring. 5.2 Archiving of Data that are Not Project-Specific These data are PLC data as well as GSD files and PLC libraries if they are not saved project-specifically but target-specifically. Special GSD files go to folder "C:\Program Files\Rexroth\IndraWorks\ IndraLogic\Targets\<target name>\userconfig" Special PLC libraries go to folder "C:\Program Files\Rexroth\ IndraWorks \IndraLogic\Targets\<target name>\lib" or "C:\Program Files\ Rexroth\IndraWorks\IndraLogic\Targets\Config"

38 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction

39 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 33/96 Firmware Download 6 Firmware Download Firmware Download is used to update the MTX firmware. This is necessary, for example, after you have updated the MTX software on your user panel. The firmware is transferred from the hard disk to the MTX and is saved to the flash EPROM. The user data should be archived before executing Firmware Download. See chapter 5 "Data Archival/Backup" on page 31 to find out how to archive data. All parts programs must be stopped before executing Firmware Download. The PLC must also be brought into the "Stop" state. The Firmware download is carried out in IndraWorks Engineering. Therfore, a project must have been created. Via the context menu (right mouse button), Firmware Management of the node IndraMotion MTX P60/P40/L40, the download is started. Fig.6-1: Calling the Firmware Download dialog box In the dialog Firmware Management, the Firmware available is listed on the left and the Firmare currently loaded on the right.

40 34/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Firmware Download Fig.6-2: Dialog box "Firmware Management" It is necessary to check if downloading firmware is necessary. Compare the current Firmaware in the device with the version to be loaded. The new Firmware can be loaded if necessary. Proceed as follows: 1. Mark the Firmware file to be loaded 2. Start the download via "Download"

41 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 35/96 Executing a Software Update of IndraWorks 7 Executing a Software Update of IndraWorks 7.1 Executing an Update of IndraWorks CAUTION Loss of user data! Save the user data before a software update. In this description, we assume that you use CD-ROM drive "E" for installing the update. Then click OK and confirm with <Enter>>. 1. Insert the CD into the CD-ROM drive. 2. Click Execute in the Start menu. 3. Type the letter for the drive together with ":\SETUP.EXE". When you install your system from a CD-ROM, enter, for instance, "E: \SETUP.EXE". Fig.7-1: Windows XP "Run" dialog box 4. Then click OK and confirm with <Enter>>. 5. Select the language for the setup program. Fig.7-2: Language selection The installation program is loaded; a selection box with the list of existing installations appears.

42 36/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Executing a Software Update of IndraWorks Fig.7-3: Selection dialog box 6. From the list, select the version that you want to update. Activate the selection "Update an installation". Exit the dialog box by pressing Next >. 7. A note indicating that an earlier version of IndraWorks was found appears. Fig.7-4: Message indicating IndraWorks update If you answer the query with Yes, the info screen for executing the update appears. 8. The remaining procedure is the same as for an initial installation. Please follow the instructions on the screen.

43 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 37/96 Executing a Software Update of IndraWorks Fig.7-5: Info screen for updating IndraWorks 9. When requested, complete the setup by clicking Finish. After completion of the update process, you will be prompted to restart Windows. Fig.7-6: End of the update procedure You must restart Windows and/or your computer before you can use the program. After startup, the system files are updated and registrations, if required, are executed.

44 38/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Executing a Software Update of IndraWorks This completes the setup.

45 Installation Instruction Rexroth IndraMotion MTX Electric Drives 8 Restoring Data 8.1 Restoring Data That Are Not Project-Specific 8.2 Restoring the IndraWorks Project These data are PLC data as well as GSD files and PLC libraries if they are not saved project-specifically but target-specifically. Copy these special GSD files from the backup folder to folder "C:\Program Files\Rexroth\IndraWorks\IndraLogic\Targets\<target name>\userconfig". Copy these special PLC libraries from the backup folder to folder "C:\Program Files\Rexroth\IndraWorks\IndraLogic\Targets\<target name>\lib". Start IndraWorks Engineering. In IndraWorks, execute Project - Restore. Select the project to restore and press Continue. Determine the destination directory and press Continue. The destination directory for the IndraWorks project must correspond with the source directory of the archive. The project paths must be identical before archiving and after restoration. See chapter 5 "Data Archival/Backup" on page 31. Check the information and continue with Finish if all settings are correct. Project restoring is now started. After successful restoring, a dialog box with a summary is displayed. Confirm this dialog box with Close. Open the restored project immediately with IndraWorks. In the IW project, start Motion Restore... MTX archive restoring is now started. Confirm the welcome dialog with Continue. Select the MTX archive to restore - only the archive part "User FE PROM" - and confirm with Continue. Confirm the entries with Finish. Now the MTX archive is restored. Exit the "Restore MTX archive - summary" dialog box with Close. In the IW project, activate Motion NC restart. Start "CMP60 Control" after a complete restart. Switch to "Start up mode 66" and trigger a soft reset (SR). Switch to "Start up mode 0" and stop the PLC via the PLC button. The password to stop the PLC is "Software". Exit the CMP60 Control. In the IW project, start Motion Restore... This starts MTX archive restoring. Confirm the welcome dialog with Continue. Bosch Rexroth AG 39/96 Restoring Data

46 40/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Restoring Data Select the MTX archive to restore and all the archive parts except the user FEPROM and confirm with Continue. Confirm the entries with Finish. Now the MTX archive is restored. Exit the "Restore MTX archive summary" dialog box by pressing "Close". In the IW project, activate Motion NC restart. Trigger a download in the IW project under HMI BTV xxxx. Acknowledge the confirmation message by pressing OK. Start IndraLogic in the IW project under Logic. Load the PLC program into the control in IndraLogic.

47 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 41/96 IndraControl P60/P40 9 IndraControl P60/P General Introduction The MTX Control tool is a commissioning and diagnostic program for PC-based IndraMotion MTX CNC controls. It is used to configure, control and monitor the IndraControl P60/P40 CNC module. MTX Control is installed on the user panel as a Windows service; it starts automatically when the PC is switched on. When MTX Control is active, the following symbol appears in the task bar: Overview General Fig.9-1: "MTX Control" symbol MTX Control monitors the status of the control and displays basic status information. MTX Control is opened by: double-clicking the MTX Control symbol in the task bar, or opening the contextual menu by clicking the right mouse button and then choosing menu item View View. After MTX Control is opened, the MTX Control window is displayed as shown below. Display of the Startup Phase General Status Information Fig.9-2: Start window The most important operating and display elements are described in the following: In normal operation (Ready), the display RUN appears on a green background. While the MTX is starting up, the individual phases that the control goes through, and thus the progress of the control startup, are displayed (see sect. chapter "Startup" on page 46). Certain basic status information is summarized in a table and is indicated by green, red or gray LEDs:

48 42/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Status Line MTX Control error In the case of serious errors due to incorrect installation or to a hardware defect, an error code, incl. plain text, is issued. TCP/IP A green LED shows the faultless functioning of TCP/IP. TCP/IP communication problems are indicated by a red LED. Field bus A green LED indicates that the field bus is working properly. Field bus problems are indicated by a red LED. UPS A green LED indicates that the UPS is working properly. A red LED indicates an error. If a UPS does not exist, a gray LED is shown. Backup battery A green LED indicates that the backup battery has the correct status. If the backup battery is discharged or if a backup battery does not exist, a red LED is shown. The following information is displayed in the status bar: IP address The IP address entered in the Windows network configuration is shown. Changes to this address can be made in the Windows control panel. If you want to change the default settings generated during installation, it is recommended that the network administrator carry this out. Working mode Monitor program stuck or does not exist monitor running download active software downloaded software started Monitor program running Firmware download running Firmware download complete Normal operation Tool Bars Fig.9-3: Working mode User level 2 (Service/Development) is required to access the functions of the first tool bar. The functions can be accessed by clicking the mouse or by pressing key combination Shift + F1 to Shift + F5. In some functions, the symbol changes according to the switch state. Firmware Download (see also chapter "Firmware Download" on page 53) Reprogram the firmware. This is done, for example, to update to a newer firmware version. MTX Shutdown The MTX is shut down in a controlled manner. Then the internal data are backed up (option). The data are backed up by creating the two files MtxpRoot.pxf and MtxpSram.dat in the Home directory of the MTX.

49 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 43/96 IndraControl P60/P40 Fig.9-4: Hardware Reset Triggers a hardware reset, which is followed by a startup of the MTX. Backup mode ON (default) After the control is shut down, a data backup is executed. Backup mode OFF Data backup is switched off. If it is determined during the shutdown that the permitted battery voltage is too low, the data are backed up even if this is OFF. UPS mode automatic (default) MTX control executes an automatic recognition of UPS. If a UPS exists, UPS mode is activated; otherwise, UPS mode is deactivated. Bosch Rexroth UPSs are detected automatically. UPS mode ON If a third-party UPS that cannot be detected automatically is used, UPS mode can be switched on manually. UPS mode OFF Startup mode (see also chapter "Startup Mode" on page 47) Functions of the first tool bar The functions of the second tool bar can be accessed mainly in user level 1 or 2 (MTB or Development/Service). The functions can be accessed by clicking the mouse or by pressing function keys F1 to F12. In some functions, the symbol changes according to the switch state. Call online help Detailed display of the MTX firmware version Software reset followed by startup Read archive (see chapter "Archive Function" on page 52) Create archive (see chapter "Archive Function" on page 52) Incorporate (mount) external file systems (see section chapter "Incorporating File Systems (Mount)" on page 53) Configuration of Ethernet interface (see chapter "Ethernet Interface" on page 57) Exiting MTX Control However, the control continues to run. This function should not be used because, if MTX Control is inactive when the user panel is shut down, a shutdown of the MTX is not triggered and the data are not backed up. Remote debugger is activated (green)

50 44/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Remote debugger is exited (red) PLC is started (green) PLC is stopped (red) PLC outputs are disabled PLC outputs are enabled PLC fixing is cancelled (green) PLC is fixed (red) Main Menu Main Menu Fig.9-5: Functions of the second tool bar All the functions that are provided by the two tool bars can also be accessed from the main menu. In addition, the main menu provides a few additional commands. The commands of the main menu, with brief descriptions, can be found in section chapter "Main Menu" on page 44. The MTX Control main menu contains all the functions that are provided by the tool bars, as well as a few additional functions that are required only in exceptional cases. The following table shows the menu structure and explanations for the individual functions:

51 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 45/96 IndraControl P60/P40 Menu entry Commands Submenu Firmware Download Shutdown Hardware Reset Load boot parameters Cleanup Memory Cleanup SRAM Cleanup FE PROM Software Reset Explanation see chapter "Firmware Download" on page 53 Proper shutdown of the MTX followed by data backup. Triggers a hardware reset, which is followed by a startup of the MTX. see chapter "Boot Parameters" on page 58 Deletes the DRAM with the exception of the monitor and boot loader memory areas. This function is required only in exceptional cases in Development. Deletes the SRAM (root file system, permanent CPL variables, residual PLC data, residual system data). This function is required only in exceptional cases. Deletes the FEPROM (firmware, FEPROM file system). This function is required only in exceptional cases. Triggers a software reset, which is followed by a startup of the MTX. Archive restore see chapter "Archive Function" on page 52 Archive create see chapter "Archive Function" on page 52 Mount Integrating the external file systems (see chapter "Incorporating File Systems (Mount)" on page 53) Ethernet Configuration Password Toolbars Tools PLC Run/Stop Clear Force Output Enable/ Disable Show System Errors Set Level 0 Change Developer toolbar MTB toolbar Remote Debugger Configuration of Ethernet interface (see chapter "Ethernet Interface" on page 57) Start and stop the PLC Delete PLC fix Enable or disable PLC outputs Display critical system errors Reset to user level 0 (see chapter "User Level" on page 59) Modification of password (see chapter "User Level" on page 59) Show/hide the tool bar for Service/Development Show/hide the MTB tool bar Activate and exit the remote debuggers Window Hide Window Close MTX Control Foreground Default size Move the MTX Control window to the foreground or the background Reset to default window size

52 46/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Menu entry Submenu Explanation? Info about MTX Control Firmware Version Software Options Hardware Info Online Help Display the software version of MTX Control Detailed display of the firmware version Display the applied software options Hardware information (PCB number, version, serial number) Call online help Startup Fig.9-6: Menu structure in main menu The MTX starts up if the user panel is switched on or if a software or hardware reset is activated. The startup occurs synchronized in 12 phases that are displayed in MTX Control: P: -3 Determines the existing hardware P: -2 RTOS startup, configure file systems P: -1 Start RTOS monitor P: 1 Initialize basic NCS communication P: 2 Initialize TCP/IP P: 3 Initialize BAPAS database P: 4 SERCOS initialization P: 5 Start NCB-TCP server P: 6 Start SERCOS startup P: 7 Mount the NFS file systems P: 8 Synchronization with SERCOS P: 9 Enable NCB-TCP server (communication with user interface) RUN Normal operation Fig.9-7: Display of startup phases The display differs as follows in the case of critical system errors, boot panic errors and an active shutdown of the MTX: SF BP SD A critical system fault has occurred A boot panic error has occurred Shutdown active Fig.9-8: Error status display If the monitor is active, the monitor status is displayed: M: A Ethernet active M: 8 Ethernet inactive M: L Loading active

53 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 47/96 IndraControl P60/P40 M: d Deletion active M: NMI The monitor is in an NMI routine (error or power down) M: E Internal error in monitor M: H Hardware unknown Startup Mode Fig.9-9: Display of active monitor The startup mode determines the behavior of the MTX during startup. A change to the startup mode becomes effective only during the next startup. Startup mode Meaning 0 Normal operation All existing data and file systems are retained. The root file system is checked during startup. If a defective file system is detected, a critical system error is displayed. A new (empty) root file system is automatically created during the next startup. 1 PLC stop The behavior corresponds to startup mode 0 with the difference that the PLC remains in the STOP state and the PLC user program is not processed. 2 Reloading the PLC boot project The PLC boot project is loaded to the user FEPROM. Any PLC boot project that exists in the root file system is discarded. Otherwise, the behavior corresponds to startup mode 0. 3 Protected startup In extreme cases, faulty machine parameter settings can make it impossible to start up a control. Startup mode 3 is used to carry out a startup in this situation, regardless of the set machine parameters. A startup with the minimum configuration occurs and the set machine parameters are ignored. After the startup, the invalid machine parameter settings can be corrected and a new startup with startup mode 0 can be carried out. 4 Deleting the permanent CPL variables The permanent CPL variables will be deleted; otherwise the behavior corresponds to startup mode 0. 5 Cold start The power-up management logic is not run; otherwise, the behavior corresponds to startup mode 0. 6 Bootstrap A new root file system is created; as a result, all the data of the old file system are lost. If an intact user FEPROM file system exists, the PLC boot project and configuration data are loaded from there. 7 Creation of the user FEPROM file system The user FEPROM is created; as a result, all the data of the old file system are lost. This is required, for example, if a user FEPROM file system is defective. The root file system remains. The permanent CPL variables will be deleted.

54 48/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Startup mode Meaning 8 Identical to startup mode 9 9 Debug mode This is the usual debugging mode if the control does not automatically start up after a reset. After the basic monitor is initialized, the boot loader is activated and the subsystems are loaded automatically. 10 Debug mode (without automatic loading) After the basic monitor is initialized, the boot loader is activated. Then loading can take place using TCP/IP. 11 Debug mode (without activating the boot loader) The basic monitor is initialized. Then loading can take place using TCP/ IP. 12 Identical to startup mode Identical to startup mode Identical to startup mode Debug mode (basic monitor start) Only the basic monitor is activated Data Backup Fig.9-10: Startup mode CNC module IndraControl P60/P40 has a non-volatile memory. The flash EPROM memory is permanent; no buffering is required. During the firmware download, the firmware and the FEPROM file system are copied to the flash EPROM. These areas change only during a firmware download; on the other hand, the user FEPROM is designed to be used to store configuration data it can be changed at any time. The SRAM is designed for user data. Residual PLC data, permanent CPL variables and residual system data are stored here. Furthermore, the root file system is located in the SRAM. It contains parts programs and tables as well as any other user data. Since the SRAM is battery-buffered, the data are retained even after the system is switched off. As an additional safety feature, the data in the SRAM are backed up when the MTX is shut down:

55 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 49/96 IndraControl P60/P40 Fig.9-11: Data backup File mtxproot.pxf contains the entire root file system. File mtxpsram.dat contains residual PLC data, permanent CPL variables and residual system data. Backing up the data in the SRAM can be suppressed by switching off backup mode (see section chapter "Tool Bars" on page 42). The consistency of the data in the SRAM is checked when the system is switched back on. The accuracy of the consistency check depends on the existence of a UPS. Normally, UPS mode Automatic (see chapter "Tool Bars" on page 42) is active, i.e. the USV is detected automatically. If a UPS exists, a checksum is generated for the data areas in the SRAM when shutting down. If a UPS does not exist, a checksum is not calculated when shutting down. As a result, a checksum is not checked during the next startup; instead, only a simple consistency check is carried out. If there is no error, the MTX starts up normally. If there is an error, startup does not occur; instead, the user is informed of the error situation:

56 50/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Fig.9-12: Error situation The backup files that were created last are indicated as follows:? File exists and contains no errors --- File does not exist. HW File has a checksum error Hardware incompatibility Can occur after hardware replacement. Fig.9-13: Indication of backup files The interrupted startup can be continued with one of the following options. The password for the user level is required for this: Clean startup: control startup without using the existing backup files. Startup with the last saved data files: control startup with the existing backup files (if these contain no errors). No startup No startup occurs; the monitor is activated.

57 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 51/96 IndraControl P60/P40 If the HELP button is pressed, a note with the following explanations is issued: Fig.9-14: Help dialog box After the desired start options have been selected and the START button is pressed, another message box is displayed: Fig.9-15: Message box

58 52/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 The startup is carried out by pressing the Continue button. WARNING Regardless of the selected start option, check the MTX data after a successful startup. Invalid or expired data can cause personal injury or material damage to the machine, the drives or the workpiece. As a result, it is absolutely required that parts programs, ZO tables, correction tables, tool tables, as well as permanent CPL variables, residual PLC data and system files be checked! Archive Function The archive function allows you to save the MTX user data and to restore them at a later point in time. The archived data are saved to a mounted directory in the form of an archive. If needed, the archive can be read to restore all the data. An archive is generated using the menu Commands/Archive create or directly using symbol. An archive is read to restore data using the menu Commands/Archive restore or using symbol. Parts programs and the PLC must be stopped before an archive can be generated or restored. The data can be archived/restored either wholly or selectively. The data areas are selected in the subsequent window: Fig.9-16: Data area selection User - FEPROM All the files that are stored in the user FEPROM RAM file system All the files that are stored in the root file system Machine parameters MTX machine parameters Tool tables MTX tool tables Permanent CPL variables Permanent CPL variables Remanent PLC data Remanent data of PLC System data MTX system data

59 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 53/96 IndraControl P60/P Firmware Download After pressing the OK button or the Enter key, another dialog box opens in which the name and path of the archive (extension =.tar) is entered. The archive is saved to a mounted directory. The dialog box is closed if the Cancel button or the Esc key is pressed. Pressing OK starts the archiving procedure, which can take a few minutes. Any errors that occur are recorded in a log file, which is automatically displayed when archiving is complete. The Firmware download is carried out via IndraWorks Engineering. See chapter 6 "Firmware Download" on page 33. When calling via MTX Control, the correspondig note appears. Fig.9-17: Incorporating File Systems (Mount) General Note on changed Firmware download In addition to the internal root file system, the MTX offers the possibility of incorporating external file systems using NFS. NFS (Network File System) is a standard used to distribute file system resources in the network. An NFS server provides one or more file systems in the network (exporting) that can be "mounted" (importing) by NFS clients. It is possible to mount any directory onto the hard disk of the local user panel or a USB memory stick, a disk drive or a CD/DVD drive on the USB port of the user panel in the internal directory tree of the MTX. On the other hand, directories on external PCs (e.g. a file server) that are connected via the network to the local user panel can be incorporated. If a standard installation has been made, directory c:\mnt is mounted and the control is attached in the file system under mount point /mnt. Further file systems are incorporated using the menu Commands/Mount or directly using the symbol :

60 54/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Using the Dialog Box Fig.9-18: "Mount" dialog window The left side of the dialog box that then opens contains a list of the currently incorporated directories (MOUNT LIST). The right side (MOUNT PATH) shows the file system of the local PC. Additional directories that are also to be incorporated can be selected by navigating in this area. Arrow Keys Navigation in both areas Double-Clicking the Right Mouse Button In the MOUNT PATH area The selected path is adopted in the list of incorporated directories. The list can contain up to 10 entries. If an existing entry is highlighted before the transfer, it is overwritten by the new path. In the MOUNT LIST area Ctrl+S The selected entry is removed from the list. The same as double-clicking the right mouse button in the MOUNT PATH area. Function Key F2 The properties of the entry highlighted in the list of incorporated directories can be modified. When changing the name, ensure that this always starts with a "/" and that the name does not already exist in another entry. If an error occurs, a corresponding error message is issued. Other properties in addition to the name can be modified: r+ r- c+ c- The selected directory is incorporated in read-only format. The data can be read from the MTX, but they cannot be modified. The selected directory is incorporated in read and write format. Activates the cache for this directory Deactivates the cache for this directory Function Key F5 Updates the display

61 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 55/96 IndraControl P60/P40 Escape Key Exits the dialog box. All changes are discarded. Return Key Adopts the changes and closes the dialog box. Tab Key Switches between the MOUNT PATH and MOUNT LIST areas. Closes the Edit window for the name in table MOUNT LIST. After the dialog box is closed by pressing Enter, the entered data are saved as boot parameters, i.e. the changes are saved in the boot parameter file and transferred to the MTX. The boot parameters are evaluated only during the next startup of the MTX, i.e. you must execute a software or hardware reset to let the new settings go into effect. Incorporating directories on external PCs, such as a file server in the user panel network, can be accomplished only by manually modifying the boot parameter file. You can find more information in section chapter "Boot Parameters" on page Using the USB Stick on the MTX as the Mount Directory General Configuration The root directory of a USB stick should be mounted. The MTX will name the directory "USB". Mounting a subfolder on an USB stick is not recommended. This will lead to various errors in connection with a soft reset when the stick is not inserted.

62 56/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 MTX Boot Parameter Fig.9-19: Root directory of a mounted USB stick 1. Adjust file...\indraworks\mtx\mtxctrl\pccpboot ini as follows. Program: #BPAR #STUPFILE NFSMOUNT :/C/mnt /mnt rw c+ NFSMOUNT Only one mount directory at a time can be cached internally with "c+". All other mounts should be cached with "c-". 1. Select menu item "Load boot parameter" in the MTX control.

63 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 57/96 IndraControl P60/P40 NFS Parameters Fig.9-20: Load boot parameter 1. Adjust file...\indraworks\mtx\bin\export.us as follows: Program: C:\mnt mtxctrl localhost E:\ mtxctrl localhost 1. Reload (right mouse button on symbol in the taskbar) Fig.9-21: Carrying Out an MTX Soft Reset (SR). Reloading "export.us" Ethernet Interface Fig.9-22: Executing a soft reset CNC module IndraControl P60/P40 has an on-board Ethernet interface. The interface is configured using the menu (Commands/Ethernet Configuration or directly using symbol. The current settings are displayed in the following entry screen.

64 58/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Fig.9-23: Entry screen The displayed parameters IP address, Subnet mask standard gateway and transfer rate can be modified. The following 5 values can be entered for the transfer rate: AUTO 10HX 10HX 10HX Boot Parameters 10 Mbits half duplex 100 Mbits half duplex 10 Mbits half duplex 10HX 100 Mbits half duplex The new values are adopted by pressing the OK button. The entered data are saved as boot parameters, i.e. the changes are saved in the boot parameter file and transferred to the MTX. The boot parameter will not be evaluated until the next startup of the MTX. A software or hardware reset must be executed so that the new settings can go into effect. If the entry screen is closed by pressing Cancel, all the changes are discarded and the parameters remain as they were. If the Ethernet interface is not configured, all parameters have a value of zero. The IndraControl P60/P40 is integrated as a network card into the Windows operating system. As a result, from a logic point of view, two interfaces exist. The first interface uses the PCI bus. This interface is used mainly for communication with the MTX interface and with the PLC programming system. It is configured in the Windows Control Panel. The second interface is the Ethernet interface on the IndraControl P60/P40 module (on-board), whose configuration is described here. The MTX boot parameters are located in file mtxpboot<pcb number >.ini in the home directory of the control. (The PCB number can be determined using the menu entry in the main menu also see chapter "Main Menu" on page 44.) In every software or hardware reset, the boot parameters are read from this file and copied to the SRAM. Then startup occurs with the current boot parameters. If the mount parameters or the Ethernet interface configuration is changed, the set values are saved to the boot parameter file and are copied to the SRAM.

65 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 59/96 IndraControl P60/P40 The boot parameter file contains information about the incorporated external file systems and the configuration parameters of the Ethernet interface. #BPAR #STUPFILE NFSMOUNT :/c/mnt /mnt rw c+ #ESTUPFILE #NET IPADDR SNMASK GWADDR #ENET #EBPAR The section starting with #STUPFILE is used to input the mount parameters; it is completed with #ESTUPFILE. An entry with keyword NFSMOUNT exists for every incorporated file system. The listed parameters depend on the entries made during installation. The example above applies to the default installation. Another section is identified by #NET and #ENET. The Ethernet interface parameters are located in this section. To avoid the incorrect setting of parameters, the boot parameter file should not be modified manually. Modifications should be made only with the corresponding MTX Control dialog boxes (see section chapter "Incorporating File Systems (Mount)" on page 53 and chapter "Ethernet Interface" on page 57) User Level Numerous functions are password-protected to prevent access to unauthorized persons. MTX Control administrates three user levels: Level 0 (user): functions that every user may use. Level 1 (machine manufacturer): commands to control the MTX and the integrated PLC. Level 2 (service/developer): commands for specific stopping and starting of the MTX control (data loss possible). Higher user levels automatically also have access to all the functions of the subordinate user level. Changes to the user level always are in effect only until midnight. When the date changes, the user level is automatically reset to 0. An explicit reset can be carried out using the menu Password/Set level 0. If a function that is not permitted in the current user level is selected, a request for entering the password for the required user level appears. The following is an example for user level 2:

66 60/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Fig.9-24: Password entry After the correct password has been entered and confirmed by pressing Enter, the requested function is executed. The entry can be cancelled by pressing Esc; in this case, the requested function is not executed. The passwords defined by Bosch Rexroth can be changed at any time. This is accomplished using the menu Password/Change. Then the following entry screen is displayed: Contextual Menu Fig.9-25: Change password Proceed as follows to change a password: Select box for password level (select the user level) The user level for which the password is to be changed is set here. Enter old password The password can be changed only by entering a valid password. Enter the current valid password here. Enter new password After the new password has been entered, it must be entered again in the same window for confirmation. The text above the entry field changes from Enter new passwordto Verify new password. If the entries agree, the password change goes into effect by pressing the OK button or Enter. If Esc or the Cancel button is pressed, changing the password can be cancelled at any time. If you click the right mouse button on the MTX Control symbol in the taskbar, the MTX Control contextual menu opens. It provides the following possibilities: View

67 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 61/96 IndraControl P60/P Call Parameters MTX control is opened. You can find a description of the most important display and operating elements in section chapter "Overview" on page 41. Help Exit Call online help. Exit MTX Control. The control continues to run anyway. This function should not be used because, if MTX Control is inactive when the user panel is shut down, a shutdown of the MTX is not triggered and the data are not backed up. During installation, MTX Control is installed as a Windows service on the user panel. Starting MTX Control as a Windows application using the command line or using a link is thus not necessary. The following is provided for information purposes only. Call parameters generally begin with the character "/" or "-" (e.g. /install or - install). The individual parameters have the following meanings: install Installs MTX control as a Windows service. This occurs during installation. remove Uninstalls Windows service MTX Control. This occurs, for example, during uninstallation of the MTX software. no service task view Starts MTX Control as an application. The MTX Control symbol is shown in the taskbar if MTX Control is active. Opens the MTX control window. target <IP address or target name> Shows the IP address or the name of the MTX with which MTX Control is connected. If this parameter is missing, a connection is made to the first MTX in the system. h or? Displays the list of parameters described here. 9.2 IP Address Overview Each basic PC device contains a IndraControl P60/P40 plug-in card with an internal network connection in a separate subnet an Ethernet connection. Example:

68 62/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Fig.9-26: Plug-in card in basic PC device Configuration of Communication Interface General Setting the IP Address Network Adapter The data exchange between the basic PC device and the IndraControl P60/ P40 plug-in card takes place using TCP/IP. The IndraControl P60/P40 plug-in card and the network adapter are treated as an internal subnet with fixed IP addresses. During configuration, the IndraControl P60/P40 plug-in card is assigned a fixed IP address which makes it possible for the basic PC device to communicate with this card. In addition, a default setting is assigned to the symbolic name for the IndraControl P60/P40 plug-in card. Check and make note of the settings if changes are to be made to the current IP addresses. All following settings correspond to the Setup defaults. Proceed as follows to check or adjust TCP/IP settings for the network adapter of the IndraControl P60/P40 plug-in card: 1. Select the Windows XP menu: Start Settings Network Connections. 2. Choose LAN connection "PCC-P Numerical Controller".

69 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 63/96 IndraControl P60/P40 3. Choose File Properties. 4. Choose "TCP/IP Internet protocol". 5. Press the "Properties" button. 6. Check the settings for the IP address and the subnet screen: The IP address is: The subnet screen is: Fig.9-27: IP addresses Setting IP Address of IndraControl P60/P40 Plug-in Card If the IP addresses mentioned above differ from the defaults in the standard installation, take note of the current IP addresses for the next software update so that you can adapt your control to the local network. The IndraControl P60/P40 plug-in card is known as "PCC-P Numerical Controller" in the system. Proceed as follows to check or adjust the IP addresses for the IndraControl P60/P40 plug-in card: 1. Select the Windows XP menu: Start Settings Network Connections. 1. Choose LAN connection "PCC-P Numerical Controller". 2. Choose File Properties. 3. Press the "Configure" button.

70 64/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 4. Select tab "Advanced". 5. In the "Property" window, check and, if necessary, adjust the following entries: PCC-P Default Gateway:The default address of the network adapter is: It must always be located in the following subnet. PCC-P IP Address: The default IP address is: PCC-P Name: Symbolic name of the plug-in card installed in "Setup" (default: "mtxctrl"). PCC-P Subnet Mask: The default subnet is: Fig.9-28: Ethernet Connection of Basic PC Device Settings of IndraControl P60/P40 plug-in card If the basic PC device is also connected to a network, communication takes place using the Ethernet connection via TCP/IP. A fixed IP address is also required for this connection. Check and make note of the TCP/IP and network card settings for the existing hardware components if changes are to be made to the current IP addresses. The IP addresses may have to be adjusted if: a search is made for another IP address for the basic PC device during a software update.

71 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 65/96 IndraControl P60/P Order of Network Connections 9.3 Network Settings General Information several basic PC devices are located in a company network and additional basic PC devices will be added using IndraControl P60/P40. the address of the company network has changed. the entries were overwritten after reinstalling Windows on the basic PC device. When Windows XP is installed, a standard network connection which is called "LAN connection" is set up automatically. The basic PC device can be connected to a network with this connection. This "LAN connection" must be first in the order of network connections. If the basic PC device is equipped with an IndraControl P60/P40 control module; after driver installation, another network connection is displayed - this must be the second network connection. The name of the second network connection can be selected freely (e.g. IndraControl P60). The order of network connections can be checked or corrected as follows: Start Settings Network connections "Advanced" tab Advanced settings In the connections window: 1. LAN connection 2. IndraControl P60/P40 3. possibly further network connections Enabling a CD Drive in a Network Access authorizations By highlighting the corresponding network connection and then clicking the "up" or "down" arrow, the order can be modified in the "Connections" window. You can obtain detailed information about the TCP/IP protocol or about the network settings from your network administrator and/or in the Microsoft operating system documentation. It is recommended that your network administrator make all network-related settings. Before a CD-ROM drive can be accessed from another computer (client PC), it must be enabled, i.e. permission to use this unit on the computer in which the drive is installed (server PC) must have been granted. In Windows, the administrator can set up "groups" with a "user profile" for corresponding privileges to enable network drives. If no such "group" has been defined, only the administrator can carry out enablement. 1. Insert the CD with the software into the CD-ROM drive of the server PC. 1. Click the symbol "My Computer" and then "CD-ROM". 2. Select menufile Enabling and safety..."enabled as". 3. Select tab "Enablement". 4. Activate "Enable this folder in the network". 5. Enter "CD" as the enablement name.

72 66/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Fig.9-29: Enabling a network drive The released CD ROM can be identified with the symbol Connecting to a Network Enabled in the CD-ROM Drive The computer to which access to the CD-ROM drive is to be assigned (client PC) must connect the enabled CD-ROM drive of the server PC with its file system (directory). Search for the enabled CD directory "CD" on the server PC: 1. Choose Network environment. 2. Press the "Search" button in the toolbar. 3. Enter the name of the server PC (e.g. IPCREXIND01) and click the "Search" button. 1. Click the symbol of the server PC and search for the enabled drive "CD". 2. Click "CD" and choose File - Network Connect Now assign a drive letter (e.g. "Z:") to "CD". If this is set up by the administrator, access to the server PC requires a password before a network connection can be established.

73 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 67/96 IndraControl P60/P40 4. Insert the CD-ROM into the drive. 5. In Windows Explorer, check whether the contents of the CD are read. Fig.9-30: Connecting a network drive Access to the IndraControl P60/P40 from an External PC (Routing) Overview Applications such as IndraWorks or IndraLogic can access a basic PC device with an IndraControl P60/P40 plug-in card from any network PC via Ethernet. In this case, a route must be entered on the network PC. Conditions Fig.9-31: Example of external access The network PC and the basic PC device must be located in the same subnet. Example (subnet ): Network PC: IP address Basic PC device: IP address "IP forwarding" must be activated in the basic PC device.

74 68/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl P60/P40 Entering a Route Example: Automatic entry in the Registry for installation of the IndraControl P60/ P40software. A route for subnet must be entered on the network PC. To do this, run the following MS-DOS command line: route add -p <subnet address> MASK <subnet mask> <IP address of basic PC device> route add -p MASK (Parameter "-p" stands for permanent route)

75 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 69/96 IndraControl L40 10 IndraControl L MTX Compact Firmware Download using IW Engineering Desktop The firmware of IndraControl L40 can be updated via Engineering Desktop using the Firmware Management dialog box. The dialog box is called using the contextual menu of the device node "IndraMotion MTX L40" or - for the selected device node - with the menu item of the same name: Fig.10-1: Calling the Firmware Download dialog box The device name and IP address of the device are displayed in the "Firmware Management" dialog box. The stored versions of firmware packages are listed in the selected Firmware directory in the left half of the dialog box. The firmware version of the selected device is displayed in the right half. A firmware download is executed as follows: 1. Bring the PLC to STOP; no firmware download is possible otherwise. 2. Select the directory with the firmware packages. 3. Select the desired firmware package using the version designation. 4. Check the checkbox "Restart after download". This checkbox is normally selected to automatically boot the selected firmware package after the firmware download. 5. The download is carried out by pressing the <Download> button. 6. A booting process must be triggered for activation of the firmware. This happens automatically when the checkbox "Restart after download" is selected.

76 70/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl L40 Fig.10-2: The Firmware Management dialog box The progress of the firmware download is shown by a progress bar. The download can be cancelled (e.g. if the wrong firmware package was selected by mistake). After cancellation, a new firmware package should be loaded immediately to ensure that the firmware is complete during the following boot procedure Incorporating File Systems (Mount) In addition to the internal root file system, the MTX offers the possibility of incorporating external file systems using NFS. NFS (Network File System) is a standard used to distribute file system resources in the network. An NFS server provides one or more file systems in the network (export) that can be mounted (import) by NFS clients. It is possible to mount any directory onto the hard disk of the local user panel or a USB memory stick, a disk drive or a CD/DVD drive on the USB port of the user panel in the internal directory tree of the MTX. On the other hand, directories on external PCs (e.g. a file server) that are connected via the network to the local user panel can be incorporated. Add mounted directories or edit existing ones in the Engineering project using menu item "Configure mount directories" on device node "IndraMotion MTX L40". After the required data have been loaded from the control, the following dialog box appears:

77 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 71/96 IndraControl L40 Fig.10-3: Overview of the MTX compact mount directories Here you can see an overview of the directories mounted in the control. The following information is displayed: Target address: address of the server with NFS enablement Target directory: name of enablement Mount name: name of the directory in the file system of the control Read only: +: read access only -: read and write access Cache +: Cache for the directory is activated -: Cache for the directory is deactivated Only one mount directory can be cached. Use the buttons to add an entry or to edit or delete a selected entry. The maximum number of entries is 10. Editing occurs in a separate dialog box:

78 72/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl L40 Fig.10-4: Editing mount directories Ensure that the directories entered here have been enabled properly Operator Panel Handling / MTX Compact Status Display Boot Procedure The operator panel informs the user of the status of control IndraControl L40 during the boot process and during operation. Selected operations are also possible. During booting of the IndraControl L40, the individual phases are shown on the display. The phases are subdivided into the following sections: 1. Starting the operating system: BOOT1.nn After activating the CML40, the display remains dark for a few seconds. Then the start of operating system is displayed by the increasing digits "nn" 2. Starting the Firmware loader: BOOT2.nn 3. Loading the firmware module: BOOT3.nn Loading the firmware module is documented by displaying module number "nn". 4. Loading the control configuration: BOOT4.nn The FEPROM file system and the file "mtxtboot.ini" with the mount point definitions belongs to the control configuration. 5. Booting the control firmware: BOOT-Pnn Boot phases of the IndraControl L40 are defined uniquely in control family IndraMotion MTX : P: -3 Determines the existing hardware P: -2 RTOS startup, configure file systems P: -1 Start RTOS monitor P: 1 Initialize basic NCS communication P: 2 Initialize TCP/IP P: 3 Initialize BAPAS database P: 4 SERCOS initialization P: 5 Start NCB-TCP server

79 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 73/96 IndraControl L40 P: 6 Start SERCOS startup P: 7 Mount the NFS file systems P: 8 Synchronization with SERCOS P: 9 Enable NCB-TCP server (communication with user interface) RUN Normal operation Boot lockout and specification of startup mode Fig.10-5: Display of startup phases The IndraControl L40 boots in the standard case with startup mode 0 (normal mode). If another startup mode should be specified, the boot process must first be prevented (boot lockout). The boot lockout will be active if the <ESC> key is held down after loading the control configuration - i.e. at the end of phase "BOOT4.nn". The IndraControl L40 now expects that the Startup mode be entered. The Startup mode can be selected with the arrow keys. The selected Startup mode can be discarded with <ESC>; the default value 0 is preselected. By pressing the <Enter> key, the boot process is continued with the selected startup mode. The meaning of the startup modes is described in the following table: Startup mode Meaning 0 Normal operation All existing data and file systems are retained. The root file system is checked during startup. If a defective file system is detected, a critical system error is displayed. A new (empty) root file system is automatically created during the next startup. 1 PLC stop The behavior corresponds to startup mode 0 with the difference that the PLC remains in the STOP state and the PLC user program is not processed. 2 Reloading the PLC boot project The PLC boot project is loaded to the user FEPROM. Any PLC boot project that exists in the root file system is discarded. Otherwise, the behavior corresponds to startup mode 0. 3 Protected startup In extreme cases, faulty machine parameter settings can make it impossible to start up a control. Startup mode 3 is used to carry out a startup in this situation, regardless of the set machine parameters. A startup with the minimum configuration occurs and the set machine parameters are ignored. After the startup, the invalid machine parameter settings can be corrected and a new startup with startup mode 0 can be carried out. 4 Deleting the permanent CPL variables The permanent CPL variables will be deleted; otherwise the behavior corresponds to startup mode 0. 5 Cold start The power-up management logic is not run; otherwise, the behavior corresponds to startup mode 0.

80 74/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction IndraControl L40 Startup mode Meaning 6 Bootstrap A new root file system is created; as a result, all the data of the old file system are lost. If an intact user FEPROM file system exists, the PLC boot project and configuration data are loaded from there. 7 Creation of the user FEPROM file system The user FEPROM is created; as a result, all the data of the old file system are lost. This is required, for example, if a user FEPROM file system is defective. The root file system remains. The permanent CPL variables will be deleted. 8 Identical to startup mode 9 9 Debug Mode This is the usual debugging mode if the control does not automatically start up after a reset. After the basic monitor is initialized, the boot loader is activated and the subsystems are loaded automatically. 10 Debug mode (without automatic loading) After the basic monitor is initialized, the boot loader is activated. Then loading can take place using TCP/IP. 11 Debug mode (without activating the boot loader) The basic monitor is initialized. Then loading can take place using TCP/ IP. 12 Identical to startup mode Identical to startup mode Identical to startup mode Debug mode (basic monitor start) Only the basic monitor is activated. Display of PLC status (right half of display) Display of SERCOS Phase (left display half) Fig.10-6: Startup mode After complete startup of the IndraControl L40, the current status of the PLC is displayed in the right half of the display. The following can be displayed: STOP RUN BRK SCYC ERR??? Fig.10-7: PLC is in STOP state. The PLC program was stopped. If this status is directly after startup of the IndraControl L40, no boot project is active. PLC is in RUN state. The loaded PLC program is executed. PLC is on a break point. The PLC program is interrupted because of troubleshooting. PLC operates in single-cycle mode. Every PLC cycle must be enabled manually. PLC program was interrupted because of a runtime error. PLC reports an unknown status. This display refers to a firmware error and should never occur. Operational states of PLC After complete startup of the IndraControl L40, the current status of the SER COS ring is displayed in the left display half. The following can be displayed: P-1 The SERCOS ring is not closed, no drives have been recognized. P0 Am attempt to close the SERCOS ring is made. P1 An attempt is made to identify all participants in the SERCOS ring.

81 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 75/96 IndraControl L40 Error Displays P2 P3 P4 Fig.10-8: The timing in the SERCOS ring is determined and set. The drives were parameterized All SERCOS participants are ready for operation. Displaying the SERCOS phases Severe errors were output on the display during operation. These errors can only be eliminated by a reboot. If necessary, a suitable startup mode must be selected previously. SF BP SD A critical system fault has occurred A boot panic error has occurred Shutdown active Reboot Fig.10-9: Error status display The errors will be specified in more detail by a four-digit number. They are described in detail in the document "Diagnosis messages". Pressing the key <ESC> and < > for approx. 8 seconds can trigger a reboot.

82 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction

83 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 77/96 Additional information 11 Additional information 11.1 Start Settings of Windows XP General Switching off the Windows Logo The following section describes a few settings for optimizing the start of the user interface for production. Some of these settings are impractical during commissioning. Modifications to the Windows XP system should be carried out only by experienced Windows XP users. You need Administrator privileges to change the settings. Proceed as follows to switch off the Windows logo that appears when the Windows XP operating system starts: 1. In Start Execute, enter "msconfig" The system configuration program starts. 2. Select tab " BOOT.INI". Fig.11-1: Autologin Windows XP System configuration program 3. In group "Start options", select the checkbox "/NOGUIBOOT" The Windows logo is now switched off. Proceed as follows to start the Windows XP operating system without logging in: 1. In Start Execute, enter "control userpasswords2" The "User Accounts" dialog box opens.

84 78/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Additional information Fig.11-2: User accounts 2. Select the user, e.g. Rexroth. (Only one user can be selected in the "Users of this computer" list if the checkbox "User must enter user name and password" is checked). 3. Uncheck the "User must enter user name and password" checkbox and exit the "User Accounts" dialog box by pressing <OK>. The login box opens IndraWorks Operation Autostart 4. Here, enter the password for the selected user name and, in the second line, confirm the password (e.g. "Rexroth"). This activates Autologin for Windows XP. The user name that has been set up logs in automatically the next time that Windows XP is started. IndraWorks Operation is to be started automatically when the PC is started. To do this, the Start file of IndraWorks Operation must be transferred to the Autostart group. Proceed as follows to do this: 1. Copy the Start file "Operation" from Start Program Files Rexroth Indraworks Operation and paste it into the folder "<installation path>\indraworks".

85 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 79/96 Additional information Fig.11-3: Copying the Start file for IndraWorks Operation 2. Start the Registration Editor "Regedit" via Start Execute. 3. In the Registration Editor, go to the path "HKEY_LOCAL_MACHINE \SOFTWARE\Microsoft\Windows\CurrentVersion\Run". 4. Add a new key with the name "MTX Operation"via Edit New Key. 5. Using the right mouse button, click Change to enter the path of the copied file. Place the path name between turned commas to avoid problems with spaces in the path name. Fig.11-4: Setting Autostart 6. Close the Registration Editor Windows XP User privileges Introduction When Windows XP is restarted, IndraWorks Operation is started automatically. If you are logged into Windows XP with Administrator privileges, the system becomes susceptible to viruses, Trojan horses and other security risks due to the high-level privileges. The following section describes which settings need to be made on the system to be able to operate the IndraMotion MTX interface with a logged-in user who only has Windows XP user privileges. The following must be carried out by a system administrator.

86 80/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Additional information Definition of Terms The term "user" is used in two ways in Windows XP. Therefore, the following specifications have been made: User: XP user: XP: Setting up an XP User Creating a New User The term "user" is used for the privileges group in Windows XP's user management. According to Microsoft, users may not carry out any random or intentional modifications to the system. Users can execute certified applications, but not most of the common applications. The term "XP user" is used for the actual XP user. This always means the Windows XP operating system. 1. Open User management under My Computer using the right mouse button and select Manage. Fig.11-5: XP computer management Computer management opens. 2. In Computer management, select Local Users and Groups Users 3. Using the right mouse button, select New User... or select an existing user in the right window and, with the right mouse button, select Properties. The User Properties window opens.

87 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 81/96 Additional information Fig.11-6: Creating a new XP user 4. Enter the basic data for the new XP user. At least a user name and a password must be entered. Press the <Create> button to transfer the data. A new Windows XP user has now been created. Fig.11-7: Filled-in XP user dialog box

88 82/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Additional information Checking/changing the privileges of an existing XP user. 1. Select an existing user account and, using the right mouse button select Properties. Fig.11-8: Properties dialog box for XP users Tab "Membership" is used to view/reassign the XP user group. 2. Check/change the group membership of the selected XP user. The XP user may have only user privileges! The <Add>/<Delete> buttons can be used to add or delete XP user groups. When <Advanced> is pressed in the Add dialog box, the existing user groups are displayed by pressing the <Search> button. Windows XP group "User" must be selected here. The XP user group is allocated by pressing <OK>.

89 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 83/96 Additional information Fig.11-9: Selecting XP user groups Enabling Required Privileges Additional group privileges should always be deleted The XP user has now been created. Repeat the procedure if you want to create additional users. Otherwise, exit User management. In order to be able to use the user interface, certain directories/files must be enabled for the user. The user interface stores data that are required to properly operate the interface in these directories/files. The user must have full access to the directories/files. If the directories have subdirectories, full access must be provided for these also. The following directories must be enabled: project directory (any directory for the project utilized by the user) user data directory ("<installation path>\indraworks\user")

90 84/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Additional information mount drives. The drives mounted for the control must have full access. According to the specifications, the mount drive is located at <C:\mnt> after installation. Indralogic data directory ("<installation path>\indraworks\indralogic") global data directory ("C:\Documents and Settings\All Users\Application Data\Rexroth"). gateway directory. ("<Windows>\Gateway Files"). The following files must have full access: <Windows>\CrypKey.ini <Windows>\dziplog.txt Enabling Files/Directories <installation path>: path that was selected for installation (default path: C: \Program Files\Rexroth) <Windows>: path for Windows XP installation (default path: C:\Windows) Check whether the privileges have also been allocated in all the substructures. 1. Select the path to be enabled in Windows XP Explorer. Using the <right mouse button>, select Enablement and Security. Select the "Security" tab. In the "Groups and User Names" window, select the "User" group or the created XP user. If the group/user does not exist, it can be added by pressing <Add>. Fig.11-10: Displaying privileges

91 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 85/96 Additional information 2. In the "Privileges" window, set "Allow full access" for the user. The modified privileges can be allocated by pressing the <Ok> or <Apply> button. The group/user now has full access Tips and Additional Notes 11.3 Version Display Calling the Version Display Showing the Version Display Carry out this procedure for all directories/files to be enabled. After you have created a project under an XP user in the <default path> and you now try to open this project under another XP user (user privileges only), you have no access to it. In this case, a shared project directory should be created. All users should have full access to the project directory. After the interface crashes or hangs, programs that are still open cannot be exited in the Task Manager (no authorization). The operating system must be quit and restarted. When the operating system is restarted, the control is also restarted. When you want to restart, always wait until the workpiece has been completed. The Version display (a.k.a. info dialog box) displays information about the currently installed software version. The info dialog box can be called only if the menu bar is active. The menu bar is activated/deactivated using <ALT+M>. When the menu bar is active, the Version display can be called using Help Info... When the info dialog box is opened, information about the installed systems in the interface is displayed.

92 86/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Additional information Version Information for MTX System 1 Suite version of the interface 2 Installed systems 3 Version information for the system or component selected under "2" Fig.11-11: Info dialog box with display of the installed systems The <Advanced> button is used to also display the components (in field "2") of the installed interface and their version information. Press button <Copy info> to read out the information from all installed files and to copy this to Notepad. Then this information can be saved to a file of your choosing. <Copy info> is used for support if problems occur in the interface. The "Copy info" procedure may take several minutes (depending on the installed systems). During this time, it is not possible to cancel the copying procedure or to work elsewhere. Button <Extra info> is not available for every entry in field "2". <Extra info> can be used to provide additional information for a system or a component. The information for the MTX system consists of at least the following parts: 1. IndraMotion MTX (system version information) 2. MTX firmware (version information about the firmware of the currently selected control) 3. MTX logical device (version information about the communication interface of the MTX) 4. IW-MTX (version information about the user software (HMI)) If a problem occurs, you should have the version information for this system / these components. Support can be provided only if you have this information.

93 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 87/96 Additional information It may also be necessary to read out the version information of other components Version Information of MTX Interface Components If the <Extra info> button is pressed when the IW-MTX is selected, a display appears indicating which software options (licenses) have been enabled for the MTX system. Fig.11-12: Display of enabled software options Version Information of MTX NC Kernel Components The version information displays information about the MTX NC kernel. No version information is shown for this component in the info dialog box. Version information about the active control is displayed only after the <Extra info> button is pressed. <Extra info> is available only in IndraWorks Desktop. No device is selected in IndraWorks Engineering. Information about the control (e.g. firmware) is displayed here using the corresponding node in the tree. Tab "Firmware" is used to display the firmware in the NC kernel. Firmware information about all main and subsidiary components is displayed.

94 88/96 Bosch Rexroth AG Electric Drives Rexroth IndraMotion MTX Installation Instruction Additional information Fig.11-13: Firmware display of all components in the MTX NC kernel Tab "Info mount" is used to display information about the MTX kernel file system. Here, you can see which drives are mounted. Fig.11-14: Display of the mounted drives in the MTX control The logical name (the name that is shown in the Navigator tree), the physical name (the name that is used to physically address the drive), the file system and the file access privileges for this area are displayed for every "drive". The following file access privileges are displayed: rw: read and write access r: read access only frw: read and write access to FEPROM. Here, writing is possible only by copying in the Navigator. It is not possible to directly edit files here. c+: the drive is cached Mount drives with the NTFS file system are usually not located in the NC kernel, but rather on a PC/BTV. Tab <Hardware> is used to display information about the hardware. Information about the hardware includes: Designation Serial number

95 Installation Instruction Rexroth IndraMotion MTX Electric Drives Bosch Rexroth AG 89/96 Additional information Hardware version Fig.11-15: Information about the hardware Version Information about LDX Component Entry "MTX Logical Device" (LDX) provides information about the communication interface. Fig.11-16: Display of information for the MTX logical device

Rexroth IndraMotion MTX Software Installation

Rexroth IndraMotion MTX Software Installation Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MTX Software Installation R911318602 Edition 02 Installation Instructions Bosch Rexroth AG Electric

More information

Rexroth IndraMotion MTX Software Installation

Rexroth IndraMotion MTX Software Installation Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MTX Software Installation R911317002 Edition 02 Installation Instructions Bosch Rexroth AG Electric

More information

Rexroth IndraMotion MLC03VRS Function Modules

Rexroth IndraMotion MLC03VRS Function Modules Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MLC03VRS Function Modules R911320093 Edition 01 Functional Description Bosch Rexroth AG Electric

More information

Rexroth IndraWorks Simulation

Rexroth IndraWorks Simulation Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraWorks Simulation R911317008 Edition 02 Application Description Bosch Rexroth AG Electric Drives Rexroth

More information

Automation Terminals Of The Rexroth Inline Product Range

Automation Terminals Of The Rexroth Inline Product Range Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Automation Terminals Of The Rexroth Inline Product Range R911317021 Edition 01 Application Description Bosch Rexroth

More information

Rexroth IndraMotion for Metal Forming Rollfeed Standard 04VRS

Rexroth IndraMotion for Metal Forming Rollfeed Standard 04VRS Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion for Metal Forming Rollfeed Standard 04VRS R911321438 Edition 02 Functional Description Bosch Rexroth

More information

Rexroth IndraControl VCH 08.1

Rexroth IndraControl VCH 08.1 Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraControl VCH 08.1 R911320190 Edition 01 Project Planning Manual Bosch Rexroth AG Electric Drives Rexroth

More information

Rexroth BTA Edition 02. Project Planning Manual. Electric Drives and Controls. Mobile Hydraulics. Linear Motion and. Industrial Hydraulics

Rexroth BTA Edition 02. Project Planning Manual. Electric Drives and Controls. Mobile Hydraulics. Linear Motion and. Industrial Hydraulics Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth BTA0. 896 Edition 0 Project Planning Manual About this

More information

Rexroth IndraMotion MLC 03VRS

Rexroth IndraMotion MLC 03VRS Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MLC 03VRS R911320103 Edition 01 Functional Description Bosch Rexroth AG Electric Drives Rexroth

More information

Rexroth IndraMotion MTX Standard NC Operation

Rexroth IndraMotion MTX Standard NC Operation Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth IndraMotion MTX Standard NC

More information

IST Intelligent Safety Technology. Application Manual SYSTEM200 DOK-CONTRL-IST********-AW01-EN-P

IST Intelligent Safety Technology. Application Manual SYSTEM200 DOK-CONTRL-IST********-AW01-EN-P IST Intelligent Safety Technology Application Manual SYSTEM200 About this Documentation IST Intelligent Safety Technology Title Type of Documentation IST Intelligent Safety Technology Application Manual

More information

Rexroth RECO Fieldline INTERBUS Devices

Rexroth RECO Fieldline INTERBUS Devices Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Rexroth RECO Fieldline INTERBUS Devices Project Planning Manual Service Automation Mobile Hydraulics

More information

Rexroth Inline SERCOS Bus Coupler

Rexroth Inline SERCOS Bus Coupler Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth Inline SERCOS Bus Coupler

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Bosch Rexroth AG Electric Drives Rexroth IndraMotion 09VRS Functional Description Title Type of Documentation Document

More information

Rexroth IndraMotion MLC 04VRS Parameter

Rexroth IndraMotion MLC 04VRS Parameter Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MLC 04VRS Parameter R911321519 Edition 02 Parameter Description Bosch Rexroth AG Electric Drives

More information

RECO Inline Counter Terminal R-IB IL CNT. Application Manual SYSTEM200 DOK-CONTRL-R-IL*CNT***-AW02-EN-P

RECO Inline Counter Terminal R-IB IL CNT. Application Manual SYSTEM200 DOK-CONTRL-R-IL*CNT***-AW02-EN-P RECO Inline Counter Terminal R-IB IL CNT Application Manual SYSTEM200 About this Documentation Counter Terminal Title RECO Inline Counter Terminal R-IB IL CNT Type of Documentation Application Manual Document

More information

Rexroth IndraDrive Mi Drive Systems

Rexroth IndraDrive Mi Drive Systems Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraDrive Mi Drive Systems R911320924 Edition 03 Project Planning Manual Bosch Rexroth AG Electric Drives

More information

Rexroth VCP-Operating Concept

Rexroth VCP-Operating Concept Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics exroth IndraControl VCP 20 Rexroth VCP-Operating Concept R911305038

More information

RECO Inline PROFIBUS DP. Application Manual SYSTEM200 DOK-CONTRL-R-IL*PBSSYS-AW02-EN-P

RECO Inline PROFIBUS DP. Application Manual SYSTEM200 DOK-CONTRL-R-IL*PBSSYS-AW02-EN-P RECO Inline PROFIBUS DP Application Manual SYSTEM200 About this Documentation PROFIBUS DP Title Type of Documentation RECO Inline PROFIBUS DP Application Manual Document Typecode Internal File Reference

More information

Rexroth IndraDrive Drive Controllers - Control Sections CSB01, CSH01, CDB01

Rexroth IndraDrive Drive Controllers - Control Sections CSB01, CSH01, CDB01 Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraDrive Drive Controllers - Control Sections CSB01, CSH01, CDB01 Project Planning Manual Bosch

More information

Rexroth IndraDrive Drive Controllers Control Sections

Rexroth IndraDrive Drive Controllers Control Sections Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraDrive Drive Controllers Control Sections R929502 Edition 05 Project Planning Manual About

More information

Rexroth BTV 16 and Rexroth BTV 40

Rexroth BTV 16 and Rexroth BTV 40 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth BTV 16 and Rexroth BTV 40 R911293569 Edition 02 Project

More information

Rexroth IndraMotion MTX System Description

Rexroth IndraMotion MTX System Description Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Rexroth IndraMotion MTX System Description Project Planning Manual Pneumatics Service R911309049 Edition 04 About this Documentation

More information

DIAX04 Drive With Electric Gear Function. Functional Description: ELS 06VRS SYSTEM200 DOK-DIAX04-ELS-06VRS**-FK01-EN-P

DIAX04 Drive With Electric Gear Function. Functional Description: ELS 06VRS SYSTEM200 DOK-DIAX04-ELS-06VRS**-FK01-EN-P DIAX04 Drive With Electric Gear Function Functional Description: ELS 06VRS SYSTEM200 About this Documentation DIAX04 ELS-06VRS Title DIAX04 Drive With Electric Gear Function Type of Documentation Functional

More information

IndraMotion for Metal Forming Rollfeed Extended 02VRS

IndraMotion for Metal Forming Rollfeed Extended 02VRS Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service IndraMotion for Metal Forming Rollfeed Extended 02VRS R911319545 Edition 01 Functional Description About

More information

NYCe Multi-axis motion control system Standard Housings & Accessories. Project Planning Manual R Edition 07

NYCe Multi-axis motion control system Standard Housings & Accessories. Project Planning Manual R Edition 07 NYCe 4000 Multi-axis motion control system Standard Housings & Accessories Project Planning Manual R911337672 Edition 07 Bosch Rexroth AG DOK-NY4000-HOUSING*ACC-PR07-EN-E Title Type of Documentation Document

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

ECODRIVE03/DURADRIVE Drives for General Automation with SERCOS and Parallel Interface. Functional Description: SGP 20VRS SYSTEM200

ECODRIVE03/DURADRIVE Drives for General Automation with SERCOS and Parallel Interface. Functional Description: SGP 20VRS SYSTEM200 ECODRIVE03/DURADRIVE Drives for General Automation with SERCOS and Parallel Interface Functional Description: SGP 20VRS SYSTEM200 About this Documentation SGP-20VRS Title ECODRIVE03/DURADRIVE Drives for

More information

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02

IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02 The Drive & Control Company IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02 Project Planning Manual R911338962 Edition 03 Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P Title Type of Documentation

More information

Linear Motion and. Electric Drives. Rexroth IndraMotion MLC 04VRS. R Edition 01. Library Description. ML_Technology. Library Description

Linear Motion and. Electric Drives. Rexroth IndraMotion MLC 04VRS. R Edition 01. Library Description. ML_Technology. Library Description Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MLC 04VRS Library Description ML_Technology R911321531 Edition 01 Library Description Bosch Rexroth

More information

Rexroth IndraControl VCP 11.2

Rexroth IndraControl VCP 11.2 Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraControl VCP 11.2 R911311481 Edition 03 Project Planning Manual II Bosch Rexroth AG Electric

More information

TransKit1 Single/Dual Axis Solution. Application Description DOK-CONTRL-WZM*TK1-AW02-EN-P

TransKit1 Single/Dual Axis Solution. Application Description DOK-CONTRL-WZM*TK1-AW02-EN-P TransKit1 Single/Dual Axis Solution Application Description TransKit1 Table of Content 1-2 Title TransKit1 Single/Dual Axis Solution Type of Documentation Application description Document Type code Internal

More information

Rexroth VAM 11.1 Rexroth VAM 41.1

Rexroth VAM 11.1 Rexroth VAM 41.1 Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Rexroth VAM 11.1 Rexroth VAM 41.1 Project Planning Manual Pneumatics Service R911308619 Edition 01 About this Documentation

More information

EFC x610 Series. Brake Chopper. Operating Instructions R Edition 01

EFC x610 Series. Brake Chopper. Operating Instructions R Edition 01 EFC x610 Series Operating Instructions R912007235 Edition 01 Record of Revision Edition Release Date Notes DOK-RCON03-EFC*BRAKE**-IT01-EN-P 2017.01 First Release Version Matching Table Copyright Firmware

More information

Rexroth IndraDrive Mi Drive Systems

Rexroth IndraDrive Mi Drive Systems Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraDrive Mi Drive Systems R911320924 Edition 01 Project Planning Manual About this Documentation

More information

Rexroth VAM 10.1 Rexroth VAM 40.1

Rexroth VAM 10.1 Rexroth VAM 40.1 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth VAM 10.1 Rexroth VAM 40.1

More information

Rexroth EcoDrive Cs Drives

Rexroth EcoDrive Cs Drives Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 0 Rexroth EcoDrive Cs Drives R995758

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Rexroth PLC Modules MTS-P01.2/G2 and MTS-P02.2/G2

Rexroth PLC Modules MTS-P01.2/G2 and MTS-P02.2/G2 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth PLC Modules MTS-P01.2/G2 and MTS-P02.2/G2 294690 Ausgabe

More information

ECODRIVE03/DURADRIVE Drive for General Automation with SERCOS and Parallel Interface. Functional Description: SGP03VRS SYSTEM200

ECODRIVE03/DURADRIVE Drive for General Automation with SERCOS and Parallel Interface. Functional Description: SGP03VRS SYSTEM200 ECODRIVE03/DURADRIVE Drive for General Automation with SERCOS and Parallel Interface Functional Description: SGP03VRS SYSTEM200 About this Documentation ECODRIVE03 SGP-03VRS Title ECODRIVE03/DURADRIVE

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Bosch Rexroth AG Title Type of Documentation Document Typecode Internal File Reference Record of Revision

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

C9900-P223 and C9900-P224

C9900-P223 and C9900-P224 Installation and Operating instructions for C9900-P223 and C9900-P224 Power Supply Units Version: 1.2 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Rexroth TRANS 200 Motion Control System

Rexroth TRANS 200 Motion Control System Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth TRANS 200 Motion Control System R911297004 Edition 01

More information

RECO Inline Profibus DP Terminal and Module Supply. Functional Description SYSTEM200 DOK-CONTRL-R-IL-PB*-BK-FK02-EN-P

RECO Inline Profibus DP Terminal and Module Supply. Functional Description SYSTEM200 DOK-CONTRL-R-IL-PB*-BK-FK02-EN-P RECO Inline Profibus DP Terminal and Module Supply Functional Description SYSTEM200 About this Documentation PROFIBUS Coupler Title Type of Documentation RECO Inline Profibus DP Terminal and Module Supply

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Rexroth VisualMotion 9 Multi-Axis Motion Control using GPP and GMP Firmware

Rexroth VisualMotion 9 Multi-Axis Motion Control using GPP and GMP Firmware Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth VisualMotion 9 Multi-Axis Motion Control using GPP and

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Documentation. Mains filter AX2090-NF50. Version: Date:

Documentation. Mains filter AX2090-NF50. Version: Date: Documentation Mains filter AX2090-NF50 Version: Date: 1.1 2015-11-11 Table of content Table of content 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Documentation issue status... 5 1.3 Appropriate

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

Levante Sistemas de Automatización y Control S.L.

Levante Sistemas de Automatización y Control S.L. Catálogos Levante Sistemas de Automatización y Control S.L. LSA Control S.L. Camí del Port 143 46470 Catarroja (Valencia) Telf. (+34) 960 62 43 01 comercial@lsa-control.com www.lsa-control.com www.boschrexroth.es

More information

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements Preface SIMATIC HMI Software SIMATIC HMI Software Programming Manual Overview 1 Range of functions of the RemoteOperate software 2 Hardware and software requirements 3 Installing RemoteOperate 4 Server

More information

BNI USB A501. User s Guide

BNI USB A501. User s Guide BNI USB-901-013-A501 User s Guide Content 1 Notes for the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross-references 2

More information

Rexroth IndraDrive Drive System

Rexroth IndraDrive Drive System Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth IndraDrive Drive System Project

More information

Rexroth IndraDrive Cs Drive Systems with HCS01

Rexroth IndraDrive Cs Drive Systems with HCS01 Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraDrive Cs Drive Systems with HCS01 R911322210 Edition 02 Project Planning Manual Bosch Rexroth

More information

Rexroth IndraDrive Drive System

Rexroth IndraDrive Drive System Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth IndraDrive Drive System Project

More information

Temposonics Magnetostrictive Linear Position Sensors

Temposonics Magnetostrictive Linear Position Sensors Temposonics Magnetostrictive Linear Position Sensors TempoLink Smart Assistant I AM V THE NEW GENERATION Table of contents 1. Introduction...3 2. Safety instructions...4 2.1 Intended use...4 2.2 Foreseeable

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

Rexroth IndraControl VCP 08.2

Rexroth IndraControl VCP 08.2 Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraControl VCP 08.2 R911310379 Edition 02 Project Planning Manual II Bosch Rexroth AG Electric

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

IndraLogic L Controller based

IndraLogic L Controller based IndraLogic L Controller based www.brberg.ru brberg@ya.ru Тел. (499) 703-31-61 2 Bosch Rexroth AG Electric Drives and Controls Documentation Powerful, with extensive functionality and interfaces Scalable

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Control unit IndraDrive Commissioning Linear axis LDx with IndraDrive control unit

Control unit IndraDrive Commissioning Linear axis LDx with IndraDrive control unit Control unit IndraDrive Commissioning Linear axis LDx with IndraDrive control unit 01.03/LDx IndraDrive/368249/en Imprint: Copyright: This manual remains the copyrighted property of SCHUNK GmbH & Co. KG.

More information

C9900-P208 and C9900-P209

C9900-P208 and C9900-P209 Installation and Operating instructions for C9900-P208 and C9900-P209 Power Supply Units Version: 1.5 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Type ME43. Quickstart

Type ME43. Quickstart Type ME43 Fieldbus gateway büs to Industrial Ethernet, PROFIBUS DPV1, CC-Link Feldbus-Gateway büs zu Industrial Ethernet, PROFIBUS DPV1, CC-Link Passerelle bus de terrain büs vers Ethernet industriel,

More information

AxN CONFIGURABLE MOTION CONTROL PLATFORM. User Manual

AxN CONFIGURABLE MOTION CONTROL PLATFORM. User Manual AxN CONFIGURABLE MOTION CONTROL PLATFORM User Manual Support Model: AxN Size2: AxN 15.30.4 AxN Size3: AxN 22.44.4 AxN 35.70.4 AxN 50.100.4 AxN Size4: AxN 70.140.4 AxN Size5: AxN 90.150.4 AxN 110.200.4

More information

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 Manual VIPA Accessories USB-MPI adapter 950-0KB31 Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 This manual is relevant for: Product Order number as of state: HW SW USB-MPI adapter VIPA

More information

User manual Quick start TSwin.net

User manual Quick start TSwin.net User manual Quick start TSwin.net Part Number: 80860.653 Version: 1 Date: 25.07.2005 Valid for: TSwin.net 4.00 BT03Ax BT05Ax BT07Ax BT21Ax TP11Ax TP21Ax Version Date Modifications 1 25.07.2005 First Edition

More information

PTZ Control VMC Joystick

PTZ Control VMC Joystick Installation and Configuration English PTZ Control VMC Joystick Rev. 1.0.0 / 2010-07-20 Information about Copyright, Trademarks, Design Patents 2010 Dallmeier electronic The reproduction, distribution

More information

PLC. IndraLogic L Controller based

PLC. IndraLogic L Controller based IndraLogic L Controller based 2 Bosch Rexroth AG Electric Drives and Controls Powerful, with extensive functionality and interfaces Scalable with the innovative IndraControl L platform Centralized and

More information

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation SIMATIC NET PG/PC - Industrial Ethernet Operating Instructions 1 Preface 2 Description of the device 3 Software installation 4 Hardware installation 5 Configuration 6 Technical specifications A Approvals

More information

Control Unit KEH-P / Force-1.DIN

Control Unit KEH-P / Force-1.DIN Translation of the Original Manual Control Unit KEH-P / Force-1.DIN Assembly and Operating Manual Superior Clamping and Gripping Translation of the Original Manual Imprint: Copyright: This manual remains

More information

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.

More information

Installation and Maintenance

Installation and Maintenance Installation and Maintenance TT1000 TT3000 TT4000 Version 1.3 e-data GmbH 01.2009 Version 1.3 1-1 1 Usage 1-3 1.1 Protection Class and Protection Type... 1-3 1.2 Safety Measures... 1-3 1.3 Before Commissioning...

More information

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating manual. GTL - Configuration tool. Please keep the manual for future use. Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01 GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33

More information

PLC. IndraLogic L Controller-based

PLC. IndraLogic L Controller-based IndraLogic L Controller-based 2 Bosch Rexroth AG Electric Drives and Controls Documentation High performance with comprehensive functions and numerous interfaces Scalable with the innovative IndraControl

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006 s SIWAREX JB Aluminum Housing Instruction Manual Edition 03/2006 Table of Contents Table of Contents... 2 Warning and Safety Terms... 3 General... 4 1 Technical Description... 5 1.1 Area of Application...

More information

engineering mannesmann Rexroth ECODRIVE Drive Controller DKC02.1 Functional Description: SSE 03VRS DOK-ECODRV-SSE-03VRS**-FKB1-EN-P Indramat

engineering mannesmann Rexroth ECODRIVE Drive Controller DKC02.1 Functional Description: SSE 03VRS DOK-ECODRV-SSE-03VRS**-FKB1-EN-P Indramat engineering mannesmann Rexroth ECODRIVE Drive Controller DKC02.1 Functional SSE 03VRS DOK-ECODRV-SSE-03VRS**-FKB1-EN-P 274827 Indramat Title ECODRIVE Drive Controller DKC02.1 Type of document Functional

More information

Techno SERVO GCODE INTERFACE

Techno SERVO GCODE INTERFACE Techno SERVO GCODE INTERFACE for the Wood LATHE Setup Quickstart Tutorial HTM01570408 Windows Version Techno, Inc. 2101 Jericho Turnike New Hyde Park, NY 11042-5416 Phone: (516) 328-3970 Fax: (516) 358-2576

More information

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741 User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual D610H, D610H MKII, D610S, D610T dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Levante Sistemas de Automatización y Control S.L.

Levante Sistemas de Automatización y Control S.L. Catálogos Levante Sistemas de Automatización y Control S.L. LSA Control S.L. Camí del Port 143 46470 Catarroja (Valencia) Telf. (+34) 960 62 43 01 comercial@lsa-control.com www.lsa-control.com www.boschrexroth.es

More information

PLC. IndraLogic V PC-based

PLC. IndraLogic V PC-based IndraLogic V PC-based 2 Bosch Rexroth AG Electric Drives and Controls Documentation High performance with comprehensive functions and numerous interfaces Scalable with the innovative IndraControl V platform

More information

VisualMotion 8 (GPP) Multi-Axis Motion Control. Project Planning Manual DOK-VISMOT-VM*-08VRS**-PR03-AE-P

VisualMotion 8 (GPP) Multi-Axis Motion Control. Project Planning Manual DOK-VISMOT-VM*-08VRS**-PR03-AE-P VisualMotion (GPP) Multi-Axis Motion Control Project Planning Manual DOK-VISMOT-VM*-RS**-PR0-AE-P About this Documentation VisualMotion Project Planning Title VisualMotion (GPP) Multi-Axis Motion Control

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information