RECO Inline Profibus DP Terminal and Module Supply. Functional Description SYSTEM200 DOK-CONTRL-R-IL-PB*-BK-FK02-EN-P

Size: px
Start display at page:

Download "RECO Inline Profibus DP Terminal and Module Supply. Functional Description SYSTEM200 DOK-CONTRL-R-IL-PB*-BK-FK02-EN-P"

Transcription

1 RECO Inline Profibus DP Terminal and Module Supply Functional Description SYSTEM200

2 About this Documentation PROFIBUS Coupler Title Type of Documentation RECO Inline Profibus DP Terminal and Module Supply Functional Description Document Typecode Internal File Reference Purpose of Documentation Document Number, B341-02/EN This documentation serves as general information for the module terminals, to specify the technical data, to specify diagrams and formulas, as reference book for detailled information. Record of Revisions Description Release Date Notes B341-02/EN 07/01 First issue Copyright 2001 Rexroth Indramat GmbH Copying this document, giving it to others and the use or communication of the contents thereof without express authority, are forbidden. Offenders are liable for the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design (DIN 34-1). Validity The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract. All rights are reserved with respect to the content of this documentation and the availability of the product. Published by Rexroth Indramat GmbH Bgm.-Dr.-Nebel-Str. 2 D Lohr a. Main Telephone +49 (0)93 52/40-0 Tx Fax +49 (0)93 52/ Dept. EP6 (UK) Dept. EP7 (CV) Dept. EP (NH) Note This document has been printed on chlorine-free bleached paper.

3 PROFIBUS Coupler Contents I Contents 1 Presentation of the Components Description of the elements and basic functions Important directions for use Appropriate use Introduction Areas of use and application Inappropriate use Safety Instructions for Electric Servo Drives and Controls Introduction Explanations Hazards by inappropriate use General Information Protection against contact with electrical parts Protection by protective low voltage (PELV) against electrical shock Protection against dangerous movements Protection against magnetic and electromagnetic fields during operations and mounting Protection against contact with hot parts Protection during handling and installation Battery safety Protection against pressurized Systems PROFIBUS Coupler R-IL PB BK Presentation and Application Characteristics Display elements Standard and device-defined diagnosis for each PROFIBUS Connection of the PROFIBUS Feed in operating voltages Configuring the hardware System termination resistors Permissible RECO Inline devices Technical Data General data System data PROFIBUS DP Interface Data of the voltage supply

4 II Contents PROFIBUS Coupler Compliance with the EMC Guideline 89/336/EEC Power terminal IB IL 24 PWR IN Representation and Description of Application Characteristics Indication elements Technical data Connections Position of the terminals Terminal assignment Internal block diagram Example of a connection Electrical isolation Segment Terminal R-IB IL 24 SEG/F Representation and Description of Application Characteristics Display elements Technical data Connections Position of the terminals Terminal assignment Internal block diagram Electrical isolation Diagrams and formulas Derating Voltage characteristics in the segment circuit in case of a fuse defect Power loss Order Information Order identification List of figures Index Service & Support Helpdesk Service-Hotline Internet Vor der Kontaktaufnahme... - Before contacting us Kundenbetreuungsstellen - Sales & Service Facilities

5 PROFIBUS Coupler Presentation of the Components Presentation of the Components 1.1 Description of the elements and basic functions Fig. 1-1: Remote bus terminals and supply modules The description includes the following components: PROFIBUS DP fieldbus coupler R-IL PB BK INTERBUS Inline power terminal without fuse R-IB IL 24 PWR IN INTERBUS Inline segment terminal without fuse R-IB IL 24 SEG/F System.eps Note: This function description is valid only in connection with the application description "Project Planning and Installation of the Module Family Inline DOK-CONTRL-R-IL*PBSSYS".

6 1-2 Presentation of the Components PROFIBUS Coupler

7 PROFIBUS Coupler Important directions for use Important directions for use 2.1 Appropriate use Introduction Rexroth Indramat products represent state-of-the-art developments and manufacturing. They are tested prior to delivery to ensure operating safety and reliability. The products may only be used in the manner that is defined as appropriate. If they are used in an inappropriate manner, then situations can develop that may lead to property damage or injury to personnel. Note: Rexroth Indramat, as manufacturer, is not liable for any damages resulting from inappropriate use. In such cases, the guarantee and the right to payment of damages resulting from inappropriate use are forfeited. The user alone carries all responsibility of the risks. Before using Rexroth Indramat products, make sure that all the prerequisites for appropriate use of the products are satisfied: Personnel that in any way, shape or form uses our products must first read and understand the relevant safety instructions and be familiar with appropriate use. If the product takes the form of hardware, then they must remain in their original state, in other words, no structural changes are permitted. It is not permitted to decompile software products or alter source codes. Do not mount damaged or faulty products or use them in operation. Make sure that the products have been installed in the manner described in the relevant documentation.

8 2-2 Important directions for use PROFIBUS Coupler Areas of use and application The RECO Inline system is a decentralized modular fieldbus-coupled input and output system. The RECO Inline system by Rexroth Indramat is intended for the cases of use listed below. Machine tools Transfer systems General automation Note: The RECO Inline system may only be used with the accessories and parts specified in this document. If a component has not been specifically named, then it may not be either mounted or connected. The same applies to cables and lines. Operation is only permitted in the specified configurations and combinations of components using the software and firmware as specified in the relevant function descriptions. 2.2 Inappropriate use The typical fields of application of RECO Inline modules are as follows: Turning machines Milling machines Machining centers General automation The RECO Inline system may only be operated under the assembly, installation and ambient conditions as described here (temperature, system of protection, humidity, EMC requirements, etc.) and in the position specified. Using the RECO Inline system outside of the above-referenced areas of application or under operating conditions other than described in the document and the technical data specified is defined as inappropriate use". The RECO Inline system may not be used if they are subject to operating conditions that do not meet the above specified ambient conditions. This includes, for example, operation under water, in the case of extreme temperature fluctuations or extreme maximum temperatures or if Rexroth Indramat has not specifically released them for that intended purpose. Please note the specifications outlined in the general Safety Instructions!

9 PROFIBUS Coupler Safety Instructions for Electric Servo Drives and Controls Safety Instructions for Electric Servo Drives and Controls 3.1 Introduction Read these instructions before the equipment is used and eliminate the risk of personal injury or property damage. Follow these safety instructions at all times. Do not attempt to install, use or service this equipment without first reading all documentation provided with the product. Read and understand these safety instructions and all user documentation of the equipment prior to working with the equipment at any time. If you do not have the user documentation for your equipment contact your local Rexroth Indramat representative to send this documentation immediately to the person or persons responsible for the safe operation of this equipment. If the product is resold, rented or transferred or passed on to others, then these safety instructions must be delivered with the product. WARNING Inappropriate use of this equipment, failure to follow the safety instructions in this document or tampering with the product, including disabling of safety devices, may result in product damage, personal injury, severe electrical shock or death! 3.2 Explanations The safety warnings in this documentation describe individual degrees of hazard seriousness in compliance with ANSI: Warning symbol with signal word Degree of hazard seriousness The degree of hazard seriousness describes the consequences resulting from non-compliance with the safety guidelines. Bodily harm or product damage will occur. DANGER Death or severe bodily harm may occur. WARNING Death or severe bodily harm may occur. CAUTION Fig. 3-1: Classes of danger with ANSI

10 3-4 Safety Instructions for Electric Servo Drives and Controls PROFIBUS Coupler 3.3 Hazards by inappropriate use DANGER High voltage and high discharge current! Danger to life, risk of severe electrical shock and risk of injury! DANGER Dangerous movements! Danger to life and risk of injury or equipment damage by unintentional motor movements! WARNING High electrical voltage due to wrong connections! Danger to life, severe electrical shock and severe bodily injury! WARNING Health hazard for persons with heart pacemakers, metal implants and hearing aids in proximity to electrical equipment! Surface of machine housing could be extremely hot! Danger of injury! Danger of burns! CAUTION CAUTION Risk of injury due to inappropriate handling! Bodily injury caused by crushing, shearing, cutting and mechanical shock or improper handling of pressurized systems! Risk of injury due to inappropriate handling of batteries! CAUTION

11 PROFIBUS Coupler Safety Instructions for Electric Servo Drives and Controls General Information Rexroth Indramat GmbH is not liable for damages resulting from failure to observe the warnings given in these documentation. Order operating, maintenance and safety instructions in your language before starting up the machine. If you find that due to a translation error you can not completely understand the documentation for your product, please ask your supplier to clarify. Proper and correct transport, storage, assembly and installation as well as care in operation and maintenance are prerequisites for optimal and safe operation of this equipment. Trained and qualified personnel in electrical equipment: Only trained and qualified personnel may work on this equipment or within its proximity. Personnel are qualified if they have sufficient knowledge of the assembly, installation and operation of the product as well as an understanding of all warnings and precautionary measures noted in these instructions. Furthermore, they should be trained, instructed and qualified to switch electrical circuits and equipment on and off, to ground them and to mark them according to the requirements of safe work practices and common sense. They must have adequate safety equipment and be trained in first aid. Only use spare parts and accessories approved by the manufacturer. Follow all safety regulations and requirements for the specific application as practiced in the country of use. The equipment is designed for installation on commercial machinery. European countries: see directive 89/392/EEC (machine guideline). The ambient conditions given in the product documentation must be observed. Use only safety features that are clearly and explicitly approved in the Project Planning manual. For example, the following areas of use are not allowed: Construction cranes, Elevators used for people or freight, Devices and vehicles to transport people, Medical applications, Refinery plants, the transport of hazardous goods, Radioactive or nuclear applications, Applications sensitive to high frequency, mining, food processing, Control of protection equipment (also in a machine). Start-up is only permitted once it is sure that the machine, in which the product is installed, complies with the requirements of national safety regulations and safety specifications of the application. Operation is only permitted if the national EMC regulations for the application are met. The instructions for installation in accordance with EMC requirements can be found in the INDRAMAT document "EMC in Drive and Control Systems. The machine builder is responsible for compliance with the limiting values as prescribed in the national regulations and specific EMC regulations for the application. European countries: see Directive 89/336/EEC (EMC Guideline). U.S.A.: See National Electrical Codes (NEC), National Electrical Manufacturers Association (NEMA), and local building codes. The user of this equipment must consult the above noted items at all times. Technical data, connections and operational conditions are specified in the product documentation and must be followed at all times.

12 3-6 Safety Instructions for Electric Servo Drives and Controls PROFIBUS Coupler 3.5 Protection against contact with electrical parts Note: This section refers to equipment with voltages above 50 Volts. Making contact with parts conducting voltages above 50 Volts could be dangerous to personnel and cause an electrical shock. When operating electrical equipment, it is unavoidable that some parts of the unit conduct dangerous voltages. DANGER High electrical voltage! Danger to life, severe electrical shock and severe bodily injury! Only those trained and qualified to work with or on electrical equipment are permitted to operate, maintain or repair this equipment. Follow general construction and safety regulations when working on electrical installations. Before switching on power the ground wire must be permanently connected to all electrical units according to the connection diagram. Do not operate electrical equipment at any time if the ground wire is not permanently connected, even for brief measurements or tests. Before working with electrical parts with voltage potentials higher than 50 V, the equipment must be disconnected from the mains voltage or power supply. The following should be observed with electrical drives, power supplies, and filter components: Wait five (5) minutes after switching off power to allow capacitors to discharge before beginning work. Measure the voltage on the capacitors before beginning work to make sure that the equipment is safe to touch. Never touch the electrical connection points of a component while power is turned on. Install the covers and guards provided with the equipment properly before switching the equipment on. Prevent contact with live parts at any time. A residual-current-operated protective device (r.c.d.) must not be used on an electric drive! Indirect contact must be prevented by other means, for example, by an overcurrent protective device. Equipment that is built into machines must be secured against direct contact. Use appropriate housings, for example a control cabinet. European countries: according to EN 50178/1998, section U.S.A: See National Electrical Codes (NEC), National Electrical Manufacturers Association (NEMA) and local building codes. The user of this equipment must observe the above noted instructions at all times.

13 PROFIBUS Coupler Safety Instructions for Electric Servo Drives and Controls 3-7 To be observed with electrical drives, power supplies, and filter components: DANGER High electrical voltage! High leakage current! Danger to life, danger of injury and bodily harm from electrical shock! Before switching on power for electrical units, all housings and motors must be permanently grounded according to the connection diagram. This applies even for brief tests. Leakage current exceeds 3.5 ma. Therefore the electrical equipment and units must always be firmly connected to the supply network. Use a copper conductor with at least 10 mm² cross section over its entire course for this protective connection! Prior to startups, even for brief tests, always connect the protective conductor or connect with ground wire. High voltage levels can occur on the housing that could lead to severe electrical shock and personal injury. European countries: EN 50178/1998, section USA: See National Electrical Codes (NEC), National Electrical Manufacturers Association (NEMA), and local building codes. The user of this equipment must maintain the above noted instructions at all times.

14 3-8 Safety Instructions for Electric Servo Drives and Controls PROFIBUS Coupler 3.6 Protection by protective low voltage (PELV) against electrical shock All connections and terminals with voltages between 5 and 50 Volts on INDRAMAT products are protective low voltages designed in accordance with the following standards on contact safety: International: IEC EU countries: see EN 50178/1998, section WARNING High electrical voltage due to wrong connections! Danger to life, severe electrical shock and severe bodily injury! Only equipment, electrical components and cables of the protective low voltage type (PELV = Protective Extra Low Voltage) may be connected to all terminals and clamps with 0 to 50 Volts. Only safely isolated voltages and electrical circuits may be connected. Safe isolation is achieved, for example, with an isolating transformer, an optoelectronic coupler or when battery-operated. 3.7 Protection against dangerous movements Dangerous movements can be caused by faulty control or the connected motors. These causes are be various such as: unclean or wrong wiring of cable connections inappropriate or wrong operation of equipment malfunction of sensors, encoders and monitoring circuits defective components software errors Dangerous movements can occur immediately after equipment is switched on or even after an unspecified time of trouble-free operation. The monitors in the drive components make faulty operation almost impossible. Regarding personnel safety, especially the danger of bodily harm and property damage, this alone should not be relied upon to ensure complete safety. Until the built-in monitors become active and effective, it must be assumed in any case that some faulty drive movements will occur. The extent of these faulty drive movements depends upon the type of control and the state of operation.

15 PROFIBUS Coupler Safety Instructions for Electric Servo Drives and Controls 3-9 DANGER Dangerous movements! Danger to life and risk of injury or equipment damage! Personnel protection must be secured for the above listed reason by means of superordinate monitors or measures. These are instituted in accordance with the specific situation of the facility and a danger and fault analysis conducted by the manufacturer of the facility. All the safety regulations that apply to this facility are included therein. By switching off, circumventing or if safety devices have simply not been activated, then random machine movements or other types of faults can occur. Avoiding accidents, injury or property damage: Keep free and clear of the machine s range of motion and moving parts. Prevent people from accidentally entering the machine s range of movement: - use protective fences - use protective railings - install protective coverings - install light curtains or light barriers Fences must be strong enough to withstand maximum possible momentum. Mount the emergency stop switch (E-stop) in the immediate reach of the operator. Verify that the emergency stop works before startup. Don t operate the machine if the emergency stop is not working. Isolate the drive power connection by means of an emergency stop circuit or use a start-inhibit system to prevent unintentional start-up. Make sure that the drives are brought to standstill before accessing or entering the danger zone. Secure vertical axes against falling or slipping after switching off the motor power by, for example: - Mechanically securing the vertical axes - Adding an external brake / clamping mechanism - Balancing and thus compensating for the vertical axes mass and the gravitational force The standard equipment motor brake or an external brake controlled directly by the servo drive are not sufficient to guarantee the safety of personnel!

16 3-10 Safety Instructions for Electric Servo Drives and Controls PROFIBUS Coupler Disconnect electrical power to the equipment using a master switch and secure the switch against reconnection for: - maintenance and repair work - cleaning of equipment - long periods of discontinued equipment use Avoid operating high-frequency, remote control and radio equipment near electronics circuits and supply leads. If use of such equipment cannot be avoided, verify the system and the plant for possible malfunctions at all possible positions of normal use before the first start-up. If necessary, perform a special electromagnetic compatibility (EMC) test on the plant. 3.8 Protection against magnetic and electromagnetic fields during operations and mounting Magnetic and electromagnetic fields generated by current-carrying conductors and permanent magnets in motors represent a serious health hazard to persons with heart pacemakers, metal implants and hearing aids. WARNING Health hazard for persons with heart pacemakers, metal implants and hearing aids in proximity to electrical equipment! Persons with pacemakers, metal implants and hearing aids are not permitted to enter following areas: - Areas in which electrical equipment and parts are mounted, being operated or started up. - Areas in which parts of motors with permanent magnets are being stored, operated, repaired or mounted. If it is necessary for a person with a pacemaker to enter such an area, then a physician must be consulted prior to doing so. Pacemaker, that are already implanted or will be implanted in the future, have a considerable deviation in their resistance to interference. Due to the unpredictable behavior there are no rules with general validity. Persons with hearing aids, metal implants or metal pieces must consult a doctor before they enter the areas described above. Otherwise health hazards will occur.

17 PROFIBUS Coupler Safety Instructions for Electric Servo Drives and Controls Protection against contact with hot parts CAUTION Housing surfaces could be extremely hot! Danger of injury! Danger of burns! Do not touch surfaces near the source of heat! Danger of burns! Wait ten (10) minutes before you access any hot unit. Allow the unit to cool down. Do not touch hot parts of the equipment, such as housings, heatsinks or resistors. Danger of burns! 3.10 Protection during handling and installation Under certain conditions unappropriate handling and installation of parts and components may cause injuries. CAUTION Risk of injury through incorrect handling! Bodily harm caused by crushing, shearing, cutting and mechanical shock! Observe general instructions and safety regulations during handling installation. Use only appropriate lifting or moving equipment. Take precautions to avoid pinching and crushing. Use only appropriate tools. If specified by the product documentation, special tools must be used. Use lifting devices and tools correctly and safely. Wear appropriate protective clothing, e.g. safety glasses, safety shoes and safety gloves. Never stay under suspended loads. Clean up liquids from the floor immediately to prevent personnel from slipping.

18 3-12 Safety Instructions for Electric Servo Drives and Controls PROFIBUS Coupler 3.11 Battery safety Batteries contain reactive chemicals in a solid housing. Inappropriate handling may result in injuries or equipment damage. CAUTION Risk of injury through incorrect handling! Do not attempt to reactivate discharged batteries by heating or other methods (danger of explosion and corrosion). Never charge batteries (danger from leakage and explosion). Never throw batteries into a fire. Do not dismantle batteries. Handle with care. Incorrect extraction or installation of a battery can damage equipment. Note: Environmental protection and disposal! The batteries contained in the product should be considered as hazardous material for land, air and sea transport in the sense of the legal requirements (danger of explosion). Dispose batteries separately from other refuse. Observe the legal requirements given in the country of installation Protection against pressurized Systems Certain Motors (ADS, ADM, 1MB etc.) and drives, corresponding to the information in the Project Planning manual, must be provided with and remain under a forced load such as compressed air, hydraulic oil, cooling fluid or coolant. In these cases, improper handling of the supply of the pressurized systems or connections of the fluid or air under pressure can lead to injuries or accidents. CAUTION Danger of injury when pressurized systems are handled by untrained personnel! Do not attempt to disassemble, to open or to cut a pressurized system. Observe the operation restrictions of the respective manufacturer. Before the disassembly of pressurized systems, lower pressure and drain off the fluid or gas. Use suitable protective clothing (for example protective eyewear, safety shoes and gloves) Remove any fluid that has leaked out onto the floor immediately. Note: Environmental protection and disposal! The fluids used in the operation of the pressurized system equipment is not environmentally compatible. Fluid that is damaging to the environment must be disposed of separate from normal waste. Observe the national specifications of the country of installation.

19 PROFIBUS Coupler PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler R-IL PB BK 4.1 Presentation and Application Characteristics Fig. 4-1: Module R-IL PB BK with clipped-on connector and end plate 6137a002.eps The PROFIBUS coupler constitutes the link between the PROFIBUS DP and the RECO Inline installation system. At an existing PROFIBUS DP, you can connect Inline modules by means of the PROFIBUS coupler at any location. In this way, you ll be able to benefit from all advantages of the module-structured installation system with the PROFIBUS, too. The PROFIBUS coupler has the following characteristics: A maximum of 63 Inline modules can be connected to the PROFIBUS DP by simply latching them to each other via the coupler. Coupler and Inline module are one station. The total of input and output data of the connected modules may not exceed 192 bytes per station. You can use the coupler with a data transmission speed of 9,6 kbit/s up to 12 MBit/s. The coupler automatically adjusts to the speed set for the PROFIBUS master. The working voltage of the coupler is 24 V DC; the range of operating temperature is 0 C to 55 C. Diagnosis is implemented locally via LEDs both on the coupler and on the Inline and loop-2 modules. Moreover, the PROFIBUS is also used to transmit all diagnosis information to the PROFIBUS master.

20 4-2 PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler Because of the intelligent wiring technology of the RECO Inline modules, the stations can be set up easily and quickly because, for instance, the extensive wiring for supplying the modules with voltage is not applicable any longer. In the easiest case, only the power supply units integrated in the PROFIBUS coupler must be supplied with 24 V DC voltage on their input side. They produce the necessary operation voltages for the PROFIBUS coupler and the connected Inline modules. Note: The connector is not included in the scope of supply of the module. Please order the connector according to the ordering information. The end plate is enclosed with the PROFIBUS DP fieldbus coupler. Place this plate as end cover of the Inline station. This plate does not have any electrical function. It protects the station from ESD pulses and the user from dangerous contact voltage. GSD 6137A003 Fig. 4-2: Diskette with device master data file (GSD) 6137a003.eps A disc is enclosed with the PROFIBUS DP fieldbus coupler It contains the GSD file required for the PROFIBUS and a bitmap file with an icon of the coupler with lined-up Inline modules.

21 PROFIBUS Coupler PROFIBUS Coupler R-IL PB BK 4-3 Display elements Position of the diagnostic indicators UM US BF FS FN PB-DP Fig. 4-3: Position of the diagnostic indicators R-IL PB BK Meaning of the diagnostic indicators 6137a005.eps LED Color Meaning State Description of LED states UM Green U Main On 24 V supply of the main circuit available Off Main circuit supply not available US Green U Segment On 24 V supply of the segment circuit available Off Segment circuit supply not available BF Red Bus Fault FS Red Failure Select FN Red Failure Number On Off On Off Flashing Off No data exchange on the PROFIBUS No failure If FS is lit, FN indicates the failure type If FS is dark, FN indicates the failure number The number of flashing pulses indicates the failure type or the failure number, depending on whether FS is lit or not. No failure Fig. 4-4: Meaning of the diagnostic indicators R-IL PB BK

22 4-4 PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler Standard and device-defined diagnosis for each PROFIBUS Failure type Meaning 1 Parameter failures on the PROFIBUS (SET_PRM telegram) 2 3 Configuration errors on the PROFIBUS (CHK_CFG telegram) Detailed information on configuration error on the PROFIBUS are indicated in 11 different error numbers. Configuration errors in the RECO Inline station Detailed information on configuration error on the RECO Inline station are indicated in 7 different error numbers. 4 Local bus error within the station Detailed information on local bus error within the station are indicated in 6 different error numbers. 5 Module failure Fig. 4-5: Diagnosis for each PROFIBUS

23 PROFIBUS Coupler PROFIBUS Coupler R-IL PB BK Connection of the PROFIBUS a006.eps Feed in operating voltages Fig. 4-6: PIN assignment of the 9-pin SUB-D connection socket Connect the PROFIBUS to the fieldbus coupler via a 9-pin Sub-D connector. Refer to the following table for the PIN assignment. PIN Assignment 1 Reserved 2 Reserved 3 RxD / TxD-P (receiver/ Transmitter data +), line B 4 CNTR-P (control signal for repeater), directional control 5 DGND (reference potential to 5 V) 6 VP (supply voltage +5 V for termination resistors) 7 Reserved 8 RxD / TxD-N (receiver/transmitter data ), line B 9 Reserved Fig. 4-7: PIN assignment R-IL PB BK Terminal points Remark 1.1, 2.1 Segment supply voltage (+24 V DC) 1.2, 2.2 Main, fieldbus coupler, logic, and interface supply (+24 V DC) 1.3, 2.3 Reference potential 1.4, 2.4 Functional earth ground (FE) Fig. 4-8: Feed in operation voltages R-IL PB BK

24 4-6 PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler Connect the fieldbus coupler according to Fig For the terminal assignment of the fieldbus coupler, refer to Fig V - (U M ) V (U S ) 4 4 PROFIBUS DP 6137A a007.eps Configuring the hardware Fig. 4-9: Connector diagram of the PROFIBUS coupler R-IL PB BK Configure the hardware at the PROFIBUS coupler using the 10-fold DIP switch. On a004.eps Fig. 4-10: DI switch of the PROFIBUS coupler Using the 10-fold DIP switch, you can set the PROFIBUS address and further behaviors of PROFIBUS coupler. For the meaning of the switches please refer to the following figure.

25 PROFIBUS Coupler PROFIBUS Coupler R-IL PB BK 4-7 DIP switches Meaning 1 to 7 PROFIBUS address in binary representation ( = in decimal representation); switch 1 defines the least significant bit (2 0 ), switch 7 the most significant bit (2 6 ). 8 Behavior in case of data errors in the Inline station (local bus error): ON = data transfer stopped after a number of attempts OFF = the station permanently attempts to restart data transfer 9 to 10 Reserved; the switches must both be set to "OFF". Fig. 4-11: Meaning of the DIP switches Note: If DIP switch 8 is set to ON, a POWER DOWN/POWER UP must be implemented on the fieldbus coupler to restart the latter. In other word, there is no automatic restart after the error has been eliminated. System termination resistors Since the PROFIBUS is a serial bus system with star-tree structure, the individual branches must be terminated with a termination resistor. The PROFIBUS coupler itself is not provided with such a resistor. For further information please refer to your PROFIBUS documents. Rexroth Indramat recommends to use a special PROFIBUS connector (mat. no ). This connector is provided with a connectable termination resistor.

26 4-8 PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler 4.3 Permissible RECO Inline devices The following table contains a list of all Inline modules that can presently be operated with the PROFIBUS DP fieldbus coupler, together with their article numbers and descriptions as well as their significant properties. Art. Identification Art. no. ID code dec/hex Length dec/hex IN adr. OUT adr. PCP Reg. length Error message Current consumption U L U ANA Digital inputs R-IB IL 24 DI / BE 194 / C2 2 bits 2 bits 35 ma R-IB IL 24 DI / BE 65 / 41 4 bits 4 bits 40 ma R-IB IL 24 DI / BE 129 / 81 1 byte 1 byte 50 ma R-IB IL 24 DI / BE 01 / 01 2 bytes 2 bytes 60 ma R-IB IL 24 DO 2-2A / BD 194 / C2 2 bits 2 bits K, Ü 35 ma R-IB IL 24 DO / BD 65 / 41 4 bits 4 bits K, Ü 40 ma R-IB IL 24 DO / BD 129 / 81 1 byte 1 byte K, Ü 60 ma R-IB IL 24 DO / BD 01 / 01 2 bytes R-IB IL 24/130 DOR 1W Analog inputs 2 bytes K, Ü 90 ma / BD 194 / C2 2 bits 2 bits 60 ma R-IB IL AI 2/SF / 7F 02 / 02 4 bytes 4 bytes 4 bytes L, P 38 ma 15 ma R-IB IL TEMP 2 RTD / 7F 02 / 02 4 bytes 4 bytes 4 bytes D 43 ma 11 ma Analog outputs R-IB IL AO 1/SF / 7D 01 / 01 2 bytes R-IB IL AO 2/U/BP / 5B 02 / 02 4 bytes Function modules *) 4 bytes 2 bytes 4 bytes L 35 ma 25 ma L 35 ma 25 ma R-IB IL CNT / BF 02 / 02 4 bytes 4 bytes 4 bytes K, A 40 ma Supply terminals R-IB IL 24 PWR IN R-IB IL 24 SEG/F Fig. 4-12: Permissible INTERBUS Inline devices *) in preparation The abbreviations in the "Error message" column are explained in Fig

27 PROFIBUS Coupler PROFIBUS Coupler R-IL PB BK 4-9 Explanation of the error messages Abbreviation K A P Ü D L Meaning signals a short-circuit or an overload of an output and/or an initiator supply voltage signals a failure of the main or the segment voltage or the sensor supply of the loop signals an overload of an output signals a failure of the internal supply voltage signals a wire break during TC operation signals that the logic voltage UL has failed or has fallen below Fig. 4-13: Explanation of error messages with INTERBUS devices

28 4-10 PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler 4.4 Technical Data General data Article identification Article number Article identification PROFIBUS DP fieldbus coupler R-IL PB BK Supply connector R-IB IL SCN-PWR IN-CP Article number Supply connector Housing dimensions 91 mm x 120 mm x 71.5 mm (W x H x D) Weight Permissible temperature 210 g (without connector) Operation Storage/transport 0 C to +55 C -25 C to +85 C Air humidity Atmospheric pressure Operation Storage/transport Operation Storage/transport Degree of protection IP20 according to IEC Safety classification Classification 3, according to VDE 0106, IEC System data Fig. 4-14: General technical data R-IL PB BK 75 % on average, 85 % occasionally 75 % on average, 85 % occasionally 80 kpa to 106 kpa (up to 2000 m above MSL) 70 kpa to 106 kpa (up to 3000 m above MSL) Number of devices per station No more than 63 Total of all I/O data per station Maximum current of the fieldbus coupler to supply the logic system of the I/O module Maximum additional current to supply the analog module PROFIBUS DP Interface Maximum 192 bytes 2 A to U L 0,5 A to U ANA Fig. 4-15: System data R-IL PB BK Copper line (RS 485), connected via a SUB-D shield connector; electrically isolated supply; shield directly connected to the functional earth ground. Fig. 4-16: PROFIBUS DP Interface

29 PROFIBUS Coupler PROFIBUS Coupler R-IL PB BK 4-11 Data of the voltage supply 24 V main incoming supply U M / 24 V segment incoming supply U S Connection method Recommended cable lengths Transmission Nominal value Tension spring terminals No more than 30m; cable routing across exposed areas impermissible Via voltage routing 24 V DC Tolerance 15 % / +20% (according to EN ) Ripple factor ± 5% Permissible range Minimum power consumption at nominal voltage (main incoming supply) Maximum power consumption at nominal voltage Safety measures Overvoltage polarity reversal 19.2 V to 30 V (including ripple factor) 0,1 A DC (in case of no-load operation, i.e. incoming PROFIBUS clipped on, no Inline devices connected) 1.25 A DC, consisting of: 0,75 A DC for logics supply 0,5 A DC for analog voltage supply Yes Yes Fig. 4-17: 24 V main incoming supply / 24 V segment incoming supply ATTENTION Protect the 24 V range with an external fuse! The 24 V range must be protected with an external fuse. The power supply unit must be able to deliver the quadruple nominal current of the external fusible cutout, to ensure that the fuse is safely tripped in case of a failure.

30 4-12 PROFIBUS Coupler R-IL PB BK PROFIBUS Coupler Compliance with the EMC Guideline 89/336/EEC Immunity test according to EN Discharge of static electricity (ESD) EN / IEC Electromagnetic fields EN / IEC Fast transients (burst) EN / IEC Transient overvoltage (surge) EN / IEC Conducted disturbances EN / IEC Noise radiation test according to EN Criterion B 6 kv contact discharge 8 kv air discharge Criterion A Field strength: 10 V/m Criterion A All interfaces: 1 kv Criterion B DC supply lines: 0.5 kv/1 kv (symmetrical/asymmetrical) Fieldbus cable shield Criterion A Test voltage 10 V Interference emitted by the housing EN Class A Fig. 4-18: Correspondence with ECM regulation 89/336/EEC R-IL PB BK

31 PROFIBUS Coupler Power terminal IB IL 24 PWR IN Power terminal IB IL 24 PWR IN 5.1 Representation and Description of Application Fig. 5-1: The terminal R-IB IL 24 PWR IN with clipped-on connector IB_IL24_PWR.bmp The terminal allows to feed the supply voltages into the main circuit. Additionally, the supply for a segment circuit can be provided at this terminal. Characteristics Supply of the main voltage Supply/provision of the segment voltage Protection of the main circuit via an external fuse Protection of the segment circuit via an external fuse is possible Diagnostic indication Note: This terminal does not have a protocol chip; accordingly, it is no bus device.

32 5-2 Power terminal IB IL 24 PWR IN PROFIBUS Coupler Indication elements Position of the diagnosis indication Fig. 5-2: Position of the diagnosis display element R-IB IL 24 PWR IN Meaning of the diagnosis display elements PWR_Diagnose_LED.bmp Identification Color Meaning UM Green 24 V voltage (in the main circuit U M) Fig. 5-3: Meaning of the diagnosis display elements R-IB IL 24 PWR IN

33 PROFIBUS Coupler Power terminal IB IL 24 PWR IN Technical data General Notes Housing dimensions 12,2 x 120 x 71.5 mm (W x H x D) Weight Permissible temperature Air humidity 44 g (without connector) Operation Storage/transport Operation Storage/transport -25 C to +55 C -25 C to +85 C 5 % to 90 %, dew formation not permissible 5 % to 95 %, dew formation not permissible Atmospheric pressure Operation Storage/transport Degree of protection IP20 according to IEC Safety classification Classification 3, according to VDE 0106, IEC kpa to 106 kpa (up to 2000 m above MSL) 70 kpa to 106 kpa (up to 3000 m above MSL) Fig. 5-4: General technical data R-IB IL 24 PWR IN 24 V peripheral supply Connection Rated value + 24 V ground Connecting points 1.2 and 2.2 connecting points 1.3 and V DC Tolerance 15 % / +20 % (according to EN ) A.C, component 5 % Permissible range Permissible current Requirements in the voltage supply 19.2 V to 30 V (including ripple factor) Max. 8 A If an isolated area is to be set up, the power terminals must be supplied from a new power supply unit. The 24 V area is to be protected with an external fuse. Fig. 5-5: Data of the 24 V peripheral supply Note: The power supply unit must be able to deliver the quadruple nominal current of the external fuse. Protective devices Overload/short-circuit in the segment circuit Overvoltage Reversed polarity No Yes Suppressor diode to limit the voltage between the connecting points 1.1 and 1.3 and between the connecting points 1.2 and 1.3 Yes Fig. 5-6: Protective devices R-IB IL 24 PWR IN Note: The power supply unit must be able to deliver the quadruple nominal current of the external fuse.

34 5-4 Power terminal IB IL 24 PWR IN PROFIBUS Coupler 5.3 Connections Position of the terminals Terminal assignment Fig. 5-7: Position of the terminals R-IB IL 24 PWR IN PWR_Lage_Stecker.bmp Terminal point Assignment 1.1, 2.1 Supply point for the segment circuit U S (+24 V); connection of a connector or a bridge in the segment level. 1.2, 2.2 Supply point for the main circuit U M (Main Circuit; +24 V). Connection of a connector or a bridge in the segment level. These connecting points are connected to each other and unilaterally with the voltage jumper of the unprotected main supply U M. The voltage jumper of the unprotected main circuit U M and the segment circuit U S together are equipped with the load capacity 8 A. 1.3, 2.3 Bonding to frame (GND) The reference potential is directly transferred to the voltage jumpers and serves simultaneously as ground reference for the peripheral and segment voltage. 1.4, 2.4 FE connection The contacts are directly connected to the voltage jumpers and the FE spring at the bottom of the housing. On latching onto a grounded mounting rail, the terminal is grounded. The terminal points 1.1, 1.2 and 1.3 are capacitively connected to FE. Fig. 5-8: Terminal assignment R-IB IL 24PWR IN Note: The maximum total current capacity through the voltage jumpers modules is 8A.

35 PROFIBUS Coupler Power terminal IB IL 24 PWR IN 5-5 Internal block diagram PWR_Schaltbild.bmp Fig. 5-9: Internal protective elements of the terminal points R-IB IL 24 PWR IN Explanation of the symbols Symbol Explanation LED Diode Fig. 5-10: Explanation of the symbols

36 5-6 Power terminal IB IL 24 PWR IN PROFIBUS Coupler Example of a connection Note: The 24 V supply must be protected via an external fuse! Fig. 5-11: Connection of the supply voltage and an external connector PWR_Anschluss.bmp Note: A switched segment circuit can be set up by means of the connector. If this is not necessary in an individual application, the segment voltage can be provided by one of the following alternatives: 1. Setting up of a bridge between the connections 1.1 (2.1) and 1.2 (2.2). 2. Separate feeding of the segment voltage. 3. Using an additional segment terminal.

37 PROFIBUS Coupler Power terminal IB IL 24 PWR IN Electrical isolation Note: For the electrical isolation of the logics level from the peripheral area, these areas must be supplied from different power supply units via the bus terminal or via the bus terminal and a power terminal. The supply devices must not be connected in the 24 V area! Make sure that GND-PE connections are available at the supply devices! Test section Common potentials 24 V main voltage, 24 V segment voltage, and GND lie on the same potential. FE is a potential area of its own. Isolated potentials 5 V supply of incoming remote bus / 7.5 V supply (bus logics) 5 V supply of next remote bus / 7.5 V supply (bus logics) 7.5 V supply (bus logics) / 24 V supply (peripheral system) 24 V supply (peripheral system) / functional earth The following table shows the potentials of a combination of bus terminal, power terminal and I/O terminal: Test voltage 500 V AC, 50 Hz, 1 min. Fig. 5-12: Test section R-IB IL 24 PWR IN / R-IB IL 24 SEG/F

38 5-8 Power terminal IB IL 24 PWR IN PROFIBUS Coupler

39 PROFIBUS Coupler Segment Terminal R-IB IL 24 SEG/F Segment Terminal R-IB IL 24 SEG/F 6.1 Representation and Description of Application Fig. 6-1: Th terminal R-IB IL 24 SEG/F with clipped-on connector IB_IL24_SEG.bmp The terminal allows for setup of a protected partial circuit (segment circuit) within the main circuit. It does not feed in voltage, and accordingly is not equipped with reverse voltage and overvoltage protection components. Characteristics Automatic setup of a partial circuit within the main circuit. Protection of the segment circuit via an internal fuse. Diagnosis indication Note: This terminal does not have a protocol chip; accordingly, it is no bus device.

40 6-2 Segment Terminal R-IB IL 24 SEG/F PROFIBUS Coupler Display elements Position of the diagnosis display elements Fig. 6-2: Position of the diagnosis display elements R-IB IL 24 SEG/F Meaning of the diagnosis display elements SEG_Diagnose_LED.bmp Identification Color Meaning US Green 24 v voltage (in the segment circuit U S; before the fuse) E Red Protection of the segment terminal (in the segment circuit U S) Fig. 6-3: Meaning of the diagnosis indications

41 PROFIBUS Coupler Segment Terminal R-IB IL 24 SEG/F Technical data General Notes Housing dimensions 12,2 x 120 x 71.5 mm (W x H x D) Weight Permissible temperature Air humidity Atmospheric pressure 44 g (without connector) Operation Storage/transport Operation Storage/transport Operation Storage/transport -25 C to +55 C -25 C to +85 C 5 % to 90 %, no dew formation 5 % to 90 %, no dew formation 80 kpa to 106 kpa (up to 2000 m above MSL) 70 kpa to 106 kpa (up to 3000 m above MSL) Degree of protection IP20 according to IEC Safety classification Classification 3, according to VDE 0106, IEC Fig. 6-4: General technical data R-IB IL 24 PWR IN Note: Voltage is supplied in the bus terminal or in the power terminal. At the segment terminal, no connections for supply voltage are required. The respective terminals are available for test purposes. Permissible total current in the voltage jumpers of the main and segment circuit Nominal current of the terminal Maximum permissible value 6.0 A 8.0 A Fig. 6-5: Permissible total current Note: The terminal is supplied with a slow 6.3 A fusible cutout. With higher crossover currents, the operator must provide for higher protection of the circuit. Protective devices Overload/short-circuit in the segment circuit Overvoltage Reversed polarity 5 x 20 fusible cutout with 6.3 A slow Protection elements in the power terminal or the bus terminal Protection elements in the power terminal or the bus terminal Fig. 6-6: Protective devices ATTENTION Note on the selection of fusible cutouts With fuses of more than 2 A, only slow fuses may be used!

42 6-4 Segment Terminal R-IB IL 24 SEG/F PROFIBUS Coupler 6.3 Connections Position of the terminals Terminal assignment Fig. 6-7: Position of the terminals R-IB IL SEG/F SEG_Lage_Stecker.bmp Terminal Signal 1.1, 2.1 Segment voltage U S (after fuse) 1.2, 2.2 Main voltage U M 1.3, 2.3 GND of supply voltages 1.4, 2.4 FE connection Fig. 6-8: Terminal assignment

43 PROFIBUS Coupler Segment Terminal R-IB IL 24 SEG/F 6-5 Internal block diagram Fig. 6-9: Internal circuit elements of the terminal points Explanation of the symbols Seg_Schaltbild.bmp Symbol Explanation LED Fuse Capacitive connection to function earth (FE) Fig. 6-10: Explanation of the symbols

44 6-6 Segment Terminal R-IB IL 24 SEG/F PROFIBUS Coupler 6.4 Electrical isolation Note: For the electrical isolation of the logics level from the peripheral area, these areas must be supplied from different power supply units via the bus terminal or via the bus terminal and a power terminal. The supply devices must not be connected in the 24 V area! Make sure that GND-PE connections are available at the supply devices! Common potentials 24 V main voltage, 24 V segment voltage, and GND lie on the same potential. FE is a potential area of its own. Isolated potentials The following table shows the potentials of a combination of bus terminal, power terminal and I/O terminal: Test section 5 V supply of incoming remote bus / 7.5 V supply (bus logics) 5 V supply of next remote bus / 7.5 V supply (bus logics) 7.5 V supply (bus logics) / 24 V supply (peripheral system) Test voltage 500 V AC, 50 Hz, 1 min. 24 V supply (peripheral system) / functional earth Fig. 6-11: Test section R-IB IL 24 PWR IN / R-IB IL 24 SEG/F

45 PROFIBUS Coupler Segment Terminal R-IB IL 24 SEG/F Diagrams and formulas Derating Load current in the segment circuit Ambient temperature Load current in segment circuit I S 55 C 4.0 A 45 C 6.3 A Fig. 6-12: Derating of the load current in the segment circuit Load current as a function of the ambient temperature Fig. 6-13: Load current as a function of the ambient temperature I S [A] Load current in the segment circuit in A T U [ C] Ambient temperature in C Voltage characteristics in the segment circuit in case of a fuse defect Diag06.bmp Note: Even after tripping of the fusible cutout, the segment circuit is not dead! Observe characteristics! Resistance (Ω) Typical output voltage (V) Typical current (ma) ,80 0, ,21 0, ,60 0, ,99 1, ,28 2,8 Fig. 6-14: Voltage and current data as a function of the resistance values

RECO Inline PROFIBUS DP. Application Manual SYSTEM200 DOK-CONTRL-R-IL*PBSSYS-AW02-EN-P

RECO Inline PROFIBUS DP. Application Manual SYSTEM200 DOK-CONTRL-R-IL*PBSSYS-AW02-EN-P RECO Inline PROFIBUS DP Application Manual SYSTEM200 About this Documentation PROFIBUS DP Title Type of Documentation RECO Inline PROFIBUS DP Application Manual Document Typecode Internal File Reference

More information

Rexroth RECO Fieldline INTERBUS Devices

Rexroth RECO Fieldline INTERBUS Devices Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Rexroth RECO Fieldline INTERBUS Devices Project Planning Manual Service Automation Mobile Hydraulics

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

RECO Inline Counter Terminal R-IB IL CNT. Application Manual SYSTEM200 DOK-CONTRL-R-IL*CNT***-AW02-EN-P

RECO Inline Counter Terminal R-IB IL CNT. Application Manual SYSTEM200 DOK-CONTRL-R-IL*CNT***-AW02-EN-P RECO Inline Counter Terminal R-IB IL CNT Application Manual SYSTEM200 About this Documentation Counter Terminal Title RECO Inline Counter Terminal R-IB IL CNT Type of Documentation Application Manual Document

More information

Rexroth Inline SERCOS Bus Coupler

Rexroth Inline SERCOS Bus Coupler Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth Inline SERCOS Bus Coupler

More information

Automation Terminals Of The Rexroth Inline Product Range

Automation Terminals Of The Rexroth Inline Product Range Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Automation Terminals Of The Rexroth Inline Product Range R911317021 Edition 01 Application Description Bosch Rexroth

More information

Rexroth BTA Edition 02. Project Planning Manual. Electric Drives and Controls. Mobile Hydraulics. Linear Motion and. Industrial Hydraulics

Rexroth BTA Edition 02. Project Planning Manual. Electric Drives and Controls. Mobile Hydraulics. Linear Motion and. Industrial Hydraulics Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth BTA0. 896 Edition 0 Project Planning Manual About this

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

IndraMotion for Metal Forming Rollfeed Extended 02VRS

IndraMotion for Metal Forming Rollfeed Extended 02VRS Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service IndraMotion for Metal Forming Rollfeed Extended 02VRS R911319545 Edition 01 Functional Description About

More information

IST Intelligent Safety Technology. Application Manual SYSTEM200 DOK-CONTRL-IST********-AW01-EN-P

IST Intelligent Safety Technology. Application Manual SYSTEM200 DOK-CONTRL-IST********-AW01-EN-P IST Intelligent Safety Technology Application Manual SYSTEM200 About this Documentation IST Intelligent Safety Technology Title Type of Documentation IST Intelligent Safety Technology Application Manual

More information

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area Data Sheet 5764B 09/2000 # % $ This data sheet is only valid in association with the INTERBUS Inline System Manual IB IL SYS

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Rexroth VCP-Operating Concept

Rexroth VCP-Operating Concept Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics exroth IndraControl VCP 20 Rexroth VCP-Operating Concept R911305038

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

ECODRIVE03/DURADRIVE Drives for General Automation with SERCOS and Parallel Interface. Functional Description: SGP 20VRS SYSTEM200

ECODRIVE03/DURADRIVE Drives for General Automation with SERCOS and Parallel Interface. Functional Description: SGP 20VRS SYSTEM200 ECODRIVE03/DURADRIVE Drives for General Automation with SERCOS and Parallel Interface Functional Description: SGP 20VRS SYSTEM200 About this Documentation SGP-20VRS Title ECODRIVE03/DURADRIVE Drives for

More information

IBS IL 24 BK RB-T-2MBD

IBS IL 24 BK RB-T-2MBD IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 01/2003 $! $ * This data sheet is only valid in association with the "Configuring and Installing the

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Rexroth PLC Modules MTS-P01.2/G2 and MTS-P02.2/G2

Rexroth PLC Modules MTS-P01.2/G2 and MTS-P02.2/G2 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth PLC Modules MTS-P01.2/G2 and MTS-P02.2/G2 294690 Ausgabe

More information

Rexroth VAM 11.1 Rexroth VAM 41.1

Rexroth VAM 11.1 Rexroth VAM 41.1 Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Rexroth VAM 11.1 Rexroth VAM 41.1 Project Planning Manual Pneumatics Service R911308619 Edition 01 About this Documentation

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

Rexroth BTV 16 and Rexroth BTV 40

Rexroth BTV 16 and Rexroth BTV 40 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth BTV 16 and Rexroth BTV 40 R911293569 Edition 02 Project

More information

Rexroth IndraMotion MLC03VRS Function Modules

Rexroth IndraMotion MLC03VRS Function Modules Electric Drives Linear Motion and Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraMotion MLC03VRS Function Modules R911320093 Edition 01 Functional Description Bosch Rexroth AG Electric

More information

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GG711S Original operating instructions Fail-safe inductive sensor GG7S 8236522 / 2 / 26 Contents Preliminary note...3. Symbols used...3.2 Warning signs used...3 2 Safety instructions...4 2. Safety-related requirements

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GI712S Original operating instructions Fail-safe inductive sensor GI712S 80236527 / 00 12 / 2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

Rexroth Inline terminal with one analog output

Rexroth Inline terminal with one analog output Electric Drives Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth Inline terminal with one analog output R911170602 Edition 01 R-IB IL AO 1/SF-PAC 1 analog output 2-wire technology

More information

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O DATASHEET NI REM-11178 Digital Output Module for Remote I/O Short circuit and overload protection Drives up to 500 ma per channel (up to 8A per module) Spring-terminal connectors allow fast wiring without

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

CM592 PROFIBUS Communication Module

CM592 PROFIBUS Communication Module Ordering Data DATA SHEET CM592 PROFIBUS Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 200 R0001 1SAP 373 200 R0001 CM592-DP, communication module PROFIBUS

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

IB IL 24/48 DOR 2/W-XC-PAC

IB IL 24/48 DOR 2/W-XC-PAC Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It

More information

Rexroth IndraMotion MTX Standard NC Operation

Rexroth IndraMotion MTX Standard NC Operation Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth IndraMotion MTX Standard NC

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

High Power Electronic Gear Installation and operation Guide

High Power Electronic Gear Installation and operation Guide High Power Electronic Gear Installation and operation Guide 96268731 GT 1 KW 230-240 V HQITS-S DGE CLI WI SC 96267936 GT 2 KW 230-240 V HO/HF DGE CLI WI SC IP21 IP21 electronical gear for 1 and 2 kw HIT-DE

More information

DI561 Digital Input Module

DI561 Digital Input Module Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital

More information

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010 Original operating instructions Fail-safe inductive sensor GI7S 704583 / 0 06 / 200 Contents Preliminary note 3. Explanation of symbols 3 2 Safety instructions 4 2. Safety-related requirements regarding

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

IB IL 24 DI 16 IB IL 24 DI 16-PAC

IB IL 24 DI 16 IB IL 24 DI 16-PAC IB IL 24 DI 16 IB IL 24 DI 16-PAC Inline Terminal With 16 Digital Inputs Data Sheet 555302 06/2003 + Features This data sheet is only valid in association with the IB IL SYS PRO UM E User Manual or the

More information

DX561 Digital Input/Output Module

DX561 Digital Input/Output Module Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI

More information

AO523 Analog Input Module

AO523 Analog Input Module Ordering Data DATA SHEET AO523 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 200 R0001 1SAP 450 200 R0001 AO523, analog output module, 16 AO, U/I, 12 bits

More information

Serial PROFIBUS Interface

Serial PROFIBUS Interface Installation Manual Serial PROFIBUS Interface Version: EN-062016-2.3 Copyright 2016 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

DIAX04 Drive With Electric Gear Function. Functional Description: ELS 06VRS SYSTEM200 DOK-DIAX04-ELS-06VRS**-FK01-EN-P

DIAX04 Drive With Electric Gear Function. Functional Description: ELS 06VRS SYSTEM200 DOK-DIAX04-ELS-06VRS**-FK01-EN-P DIAX04 Drive With Electric Gear Function Functional Description: ELS 06VRS SYSTEM200 About this Documentation DIAX04 ELS-06VRS Title DIAX04 Drive With Electric Gear Function Type of Documentation Functional

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

REFUdrive 500 RD52 Drive Control Devices Field-oriented vector control. Operating Instructions

REFUdrive 500 RD52 Drive Control Devices Field-oriented vector control. Operating Instructions REFUdrive 500 RD52 Drive Control Devices Field-oriented vector control Operating Instructions About this Documentation Title Type of Documentation REFUdrive 500 RD52 Drive Control Devices Field-oriented

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Rexroth IndraControl VCP 11.2

Rexroth IndraControl VCP 11.2 Electric Drives Linear Motion and and Controls Hydraulics Assembly Technologies Pneumatics Service Rexroth IndraControl VCP 11.2 R911311481 Edition 03 Project Planning Manual II Bosch Rexroth AG Electric

More information

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O DATASHEET NI REM-11154 Digital Input Module for Remote I/O Read digital input frequencies up to 5 khz Adjustable filter time to improve measurement quality Spring-terminal connectors allow fast wiring

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

User Manual HMI Linkbox HL01 DP/MPI

User Manual HMI Linkbox HL01 DP/MPI User Manual HMI Linkbox HL01 DP/MPI Part Number: 80860.603 Version: 1 Date: 07.05.2005 Valid for: HL01 DP/MPI Version Date Modifications 1 07.05.2005 First edition This manual, including all illustrations

More information

Documentation. Mains filter AX2090-NF50. Version: Date:

Documentation. Mains filter AX2090-NF50. Version: Date: Documentation Mains filter AX2090-NF50 Version: Date: 1.1 2015-11-11 Table of content Table of content 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Documentation issue status... 5 1.3 Appropriate

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Type ME43. Quickstart

Type ME43. Quickstart Type ME43 Fieldbus gateway büs to Industrial Ethernet, PROFIBUS DPV1, CC-Link Feldbus-Gateway büs zu Industrial Ethernet, PROFIBUS DPV1, CC-Link Passerelle bus de terrain büs vers Ethernet industriel,

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Rexroth VAM 10.1 Rexroth VAM 40.1

Rexroth VAM 10.1 Rexroth VAM 40.1 Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth VAM 10.1 Rexroth VAM 40.1

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description Primaryswitched power supply unit Data sheet 105549_en_00 PHOENIX CONTACT 20130405 1 Description The UNO POWER power supply unit impresses in worldwide use thanks to maximum energy efficiency. Low noload

More information

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05 Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs AUTOMATIONWORX Data Sheet 6885_en_05 PHOENIX CONTACT - 03/2007 Description The ILB DN 24 DI16 DO16 module is designed

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

Rexroth EcoDrive Cs Drives

Rexroth EcoDrive Cs Drives Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 0 Rexroth EcoDrive Cs Drives R995758

More information

AX522 Analog Input/Output Module

AX522 Analog Input/Output Module Ordering Data DATA SHEET AX522 Analog Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 000 R0001 1SAP 450 000 R0001 AX522, analog input/output module, 8 AI

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

NYCe Multi-axis motion control system Standard Housings & Accessories. Project Planning Manual R Edition 07

NYCe Multi-axis motion control system Standard Housings & Accessories. Project Planning Manual R Edition 07 NYCe 4000 Multi-axis motion control system Standard Housings & Accessories Project Planning Manual R911337672 Edition 07 Bosch Rexroth AG DOK-NY4000-HOUSING*ACC-PR07-EN-E Title Type of Documentation Document

More information

ILC 200 IB ILC 200 IB-PAC

ILC 200 IB ILC 200 IB-PAC ILC 200 IB ILC 200 IB-PAC Inline Controller with Programming Capabilities According to IEC 61131-3 Data Sheet 5883C04 07/2010 & & * ILC 200 IB and ILC 200 IB-PAC only differ in the scope of supply (see

More information

AI531 Analog Input Module

AI531 Analog Input Module Ordering Data DATA SHEET AI531 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 250 600 R0001 AI531, analog input module, 8 AI, U/I/Pt100, TC, 15 bits + sign, 4-wires

More information