WinCC V4. Manual Part 1/3 C79000-G8276-C Edition August Siemens Hardware

Size: px
Start display at page:

Download "WinCC V4. Manual Part 1/3 C79000-G8276-C Edition August Siemens Hardware"

Transcription

1 WinCC V4 Manual Part 1/3 Edition August 1997 Siemens Hardware

2 WinCC, SIMATIC, SINEC, STEP are Siemens registered trademarks. All other product and system names in this manual are (registered) trademarks of their respective owners and must be treated accordingly. (The reproduction, transmission or use of this document or ist contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.) (We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed.) Siemens AG All rights reserved Technical data subject to change Printed in the Federal Republic of Germany Siemens Aktiengesellschaft

3 Table of Contents / Control Center 1 The Control Center of the WinCC System Entries in the Start Menu of the Operating System System Properties Functionality Structure Client-Server Functionality Summary Menus of the Control Center Toolbar Pop-Up Menus Feedback Documentation The Menu Description of the Control Center File Menu New Creating a New Project Open Close Activate Print Feedback Documentation View Feedback Documentation Exit Shut Down Edit Menu Undo Cut Copy Paste Delete Properties View Menu Toolbar Status Bar Large Icons Small Icons List Details Update Editors Menu Editors Tools Menu Language Status of Driver Connections Status of Multi-User Operation WinCC Manual Siemens Hardware i

4 Control Center Help Menu Contents Find Index Glossary Using Help Tutorial About Control Center Project Description General Information About Projects Project Properties "General Information" Tab "Update Cycle" Tab "Hot Keys" Tab Project Window in the Control Center General Information about the Project Window Project Navigation Window Data Window Project Components in the Control Center General Information About Project Components Structure of the "Computer" Project Component Properties of the "Computer" Project Component Structure of the "Tag Management" Project Component Properties of the "Tag Management" Project Component Structure of the "Data Types" Project Component Structure of the "Editor" Project Component Properties of the "Editor" Project Component Computer General Information About a Computer "General Information" Tab Input Box "Computer Name" Selection Box "Computer Type" List Box "Client-Server List" "Startup" Tab Sequence When Starting the WinCC Runtime Module Additional Tasks/Applications "Parameters" Tab "Graphics Run Time" Tab Communication Drivers General Information About the Communication Drivers Properties of a Communication Driver Accepting a New Communication Driver Deleting a Communication Driver ii WinCC Manual

5 08.97 Control Center 8 Channel Unit General Information about a Channel Unit "System Parameters" Dialog System Parameters for the " SIMATIC S5 Ethernet Layer 4" Communication Driver "Channel Unit Properties" Dialog "Connections" Tab "General Information" Tab Connection General Information About a Connection "Connection Properties" Dialog "General Information" Tab "Groups" Tab "Tag" Tab Channel-Specific Tab Tags General Information About Tags Independent Tags in a Connection Tags in a Tag Group within a Connection Internal Tags for an Entire Project Internal Tags in a Tag Group for an Entire Project "Tag Properties" Dialog "General Information" Tab for Process Tags "General Information" Tab for Internal Tags "Limits/Reporting" Tab Cutting, Copying, or Deleting Tags Standard Data Types "Binary Tag" Data Type "Signed 8-Bit Value" Data Type "Unsigned 8-Bit Value" Data Type "Signed 16-Bit Value" Data Type "Unsigned 16-Bit Value" Data Type "Signed 32-Bit Value" Data Type "Unsigned 32-Bit Value" Data Type "Floating-Point Number 32-Bit IEEE 754" Data Type "Floating-Point Number 64-Bit IEEE 754" Data Type "Text Tag 8-Bit Character Set" Data Type "Text Tag 16-Bit Character Set" Data Type "Raw Data Type" Data Type "Text Reference" Data Type "Structure Types" Data Type WinCC Manual Siemens Hardware iii

6 Control Center "Raw Data Tags" Are a Special Form of Tags Addressing a Process Tag Addressing by Means of the Pop-Up Menu Addressing by Means of the Properties of a Tag "Address Properties" Dialog "Address" Tab for "SIMATIC S5 Ethernet TF" "Select Tag" Dialog Tag Group General Information About a Tag Group Creating a Tag Group in a New Connection Creating a Tag Group in an Existing Connection Cutting, Copying, or Deleting Tag Groups "Tag Group Properties" Dialog "General Information" Tab "Tag" Tab The Control Center Editors Editor "Alarm Logging" Editor "User Administrator" Editing the Properties of the User Administrator "Properties" Dialog Editor "Text Library" Editor "Report Designer" "Properties" Dialog Layouts in the Report Designer Creating a New Layout in the Report Designer Opening an Existing Layout in the Report Designer Renaming an Existing Layout in the Report Designer Deleting an Existing Layout in the Report Designer Viewing the Properties of an Existing Layout in the Report Designer Print Jobs in the Report Designer Creating a New Print Job in the Report Designer Deleting an Existing Print Job in the Report Designer Activating a Print Preview in the Report Designer Printing an Existing Print Job in the Report Designer Editing the Properties of an Existing Print Job in the Report Designer Renaming an Existing Print Job in the Report Designer "Properties" Dialog for Print Jobs "Print Job" Tab "Selection" Tab "Printer Specification" Tab Editor "Global Scripts" Editor "Tag Logging" iv WinCC Manual

7 08.97 Control Center 12.7 Editor "Graphics Designer" Loading a New Picture in the Graphics Designer Opening an Existing Picture in the Graphics Designer Editing the Properties of the Graphics RUNTIME Viewing the Properties of a Picture Linking New Objects in the Graphics Designer "Object OLL" DLL Converting Pictures or Libraries DDE-Server General Information about the DDE-Server Integrating Tags via DDE Local DDE-Connection DDE-Connection via a Network Special DDE-Connection to Excel Find Function In the Context Menu Preparing Search Conditions "Name" Tab "Date of Change" Tab "Additional Options" Tab Starting the Find Procedure Stopping the Search Process Appendix Adapting the Formats of Data Types Terms/Abbreviations WinCC Manual Siemens Hardware v

8 Control Center vi WinCC Manual

9 08.97 Control Center Preface Purpose of the Manual This manual is a reference which introduces you to the functions of each of the software components and their operation. You can use the table of contents or the index to find the necessary information quickly. Naturally, this is also available to you in the on-line help in a context-sensitive manner or by means of the on-line help contents. General Overview and You can find a total overview of WinCC and a configuration example in Configuration which you can execute the significant functions of the individual components Example in a practical manner in the Getting Started Manual. Additional Assistance If you have technical questions, please contact the Siemens representative in your area. You can find the addresses in the Siemens Worldwide appendix of the S7-300 Programmable Controller System, Hardware and Installation Manual, catalogs, and on CompuServe (go autforum). In addition, you can use our hotline at (911) (Fax 7001). You can find additional information on the Internet at Information about SIMATIC products Up to date information about SIMATIC products can be obtained: * from the Internet under * via fax# In addition, the SIMATIC Customer Support provides current information and downloads that can be beneficial for the utilization of SIMATIC products: * from the Internet under * via the SIMATIC Customer Support Mailbox under phone# +49 (911) * To address the mailbox, use a modem with up to V.34 (28.8 kbaud), which parameters must be set as follows: 8, N, 1, ANSI, or dial up through ISDN (x.75, 64 kbit). The SIMATIC Customer Support can be reached by phone under the number +49 (911) and by fax under the number +49 (911) Inquiries can also be made via Internet mail or mail addressed to the above mailbox. WinCC Manual Siemens Hardware vii

10 Control Center viii WinCC Manual

11 08.97 Control Center 1 The Control Center of the WinCC System Positioning the Control Center within the WinCC System: The Control Center represents the top layer within the WinCC system (Windows Control Center).All of the modules of the entire WinCC system are started from here. The Control Center Manual provides information about the following items: Functionality Structure The standard editors The manual also provides a summary of its most important topics. WinCC Manual 1-1 Siemens Hardware

12 Control Center WinCC - The Interface between Man and Machine in Automation Design: WinCC is an industrially and technologically neutral system used to handle graphics display and control system tasks in production and process automation. This system offers industrially suitable function modules for graphic display, messages, archives, and reports. Its powerful driver interface, rapid picture updating, and secure archiving functions guarantee a high availability. In addition to the system functions, WinCC offers open interfaces for user solutions. These interfaces make it possible to integrate WinCC into complex, company-wide automation solutions. Access to archive data is integrated by means of the standard interfaces ODBC and SQL. Insertion of objects and documents is integrated by means of OLE2.0 and OLE Custom Controls (OCX). These mechanisms make WinCC a competent, communicative partner in the Windows environment. WinCC is based on the 32-bit operating system MS-Windows 95 or MS-Windows NT. Both are capable of preemptive multi-tasking, which guarantees quick reaction to process events and security against loss of data in to a high degree. Windows NT also offers functions created for security and serves as the basis for the operation of servers in a WinCC multi-user system. The WinCC software itself is a 32-bit application which was developed with the most modern, object-oriented software technology. 1.1 Entries in the Start Menu of the Operating System The installation of WinCC creates several links to help programs in the \Simatic\WinCC folder of the start menu. WinCC - Database Upgrade Beginning with WinCC V4.0, the data of the configuration and runtime systems will be kept in different databases. The database of project created with an earlier version of WinCC can be divided accordingly via the "WinCC - Database Upgrade" program. WinCC - Project Duplicator If you want to work with a redundant project, the same, or at least functionally the same, project has to be created on both redundancy servers. The "WinCC - Project Duplicator" program allows you to automatically copy all project data to the redundant server partners after finishing the configuration. WinCC - Project Switcher In a redundant project, one server is always designated the master and the other the slave. The "WinCC - Project Switcher" program allows you to switch the master designation of the servers, meaning the current master will become the slave-server and the current slave will become the master-server. 1-2 WinCC Manual

13 08.97 Control Center 1.2 System Properties 1.3 Functionality Printer Output: If unfavorable color combinations are used, e.g. for the configuration of the message system, some colors can not be displayed by a black and white printer. The functionality of the Control Center can be described as follows: The Control Center contains all the management functions for the entire WinCC system. Within the Control Center, you can configure and start the run-time module. Note: If you want to edit or create a project, the run-time module must be inactive. You can find out if the run-time module is active by looking under the "File" - "Activate" menu items. Task of the Data Manager: The data manager provides the process image with tag values. The data manager is a part of the Control Center. All of the activities of the data manager run in the background. Tasks of the Control Center: The major tasks of the Control Center are the following: Complete configuration Guided introduction to the configuration (Tutorial) Customized assigning, calling, and storing of projects Management of projects, including opening, saving, moving, and copying Network-capable editing functions for multiple users (Client-Server environment) on one project. This means there is consistent data management when multiple editors are working on one project. Version management (property of each file object) Graphic representation of the configuration data Control and configuration of the picture hierarchy/system structure, for example, by means of a tree display Global Setup settings, for example, language, system/user path setting Configuration of user location-specific functions (server properties) WinCC Manual 1-3 Siemens Hardware

14 Control Center Structure Creation and editing of cross references Feedback documentation Reporting system states Destination system setting (project property) Switching between run time and configuration Test mode/simulation/operation help for configured data, including picture shift, tag simulation, state display, and message creation System Structure of the Control Center The Control Center has the following structure: Control Center WinCC Explorer within the Control Center Graphic interface for configuration under Windows 95 and Windows NT Data manager Provides the process image with tag values in the following manner: cyclically cyclically with change event-driven one time Transmits data which the data manager gets from automation systems in the following ways: By receiving By requesting 1-4 WinCC Manual

15 08.97 Control Center Function Modules Graphic system (Graphics Designer) Displays and connects the process graphically. Action editing (Global Scripts) Makes a project dynamic to your specific requirements. Message system (Alarm Logging) Outputs messages and acknowledgments Measurement value archiving and editing (Tag Logging) Edits measurement values and stores them long term Edits user-oriented data and stores them long term Report system (Report Designer) Reports system states The Control Center makes it possible for you to navigate through the WinCC applications and their data with only a few operations. The Control Center is similar in look and operation to the Explorer in Windows 95. Components of the Control Center The Control Center consists mainly of the following components: Menu Bar Toolbar Project Window WinCC Manual 1-5 Siemens Hardware

16 Control Center Client-Server Functionality General Description of a WinCC Client-Server Environment: By means of the integrated client-server functionality in WinCC, multiple users can access the same database of a project at the same time. Note: WinCC offers you the opportunity to link 1 Server with up to 63 Clients. WinCC must be installed on all of the clients as well as the server. WinCC can be implemented as a multi-user system (client-server structure). General Description of a WinCC Client-Server Installation: To use the full extent of the functions of a WinCC client-server environment, the following notes are very important: The WinCC multi-user license must be installed on each computer (all clients and the server). In addition, it is logical to create a project path on the server on which to load all of the WinCC projects. This path (for example, "<DR>:\Projects") should not be on the WinCC program path (separation of data and programs). Experience shows that it is better to store project data on a separate hard disk. Note: You must set the enable and required authorizations for the newly created project path for the users who need to work with the WinCC projects. On the WinCC server, the "aplip" path "within the WinCC installation path is generally enabled with the name "SCRIPTFCT". You cannot change the enable command or the enable name. All of the global scripts from action programming (Global Scripts)are loaded on the "aplib" path. 1-6 WinCC Manual

17 08.97 Control Center After you install WinCC on the server, start the Control Center (MCP.EXE ). During the start procedure, the "Control Center" dialog opens automatically (only the first time you start WinCC). Select "Multi-User System" in the dialog and use the "OK" button. In the "Create New Project" dialog that then appears, set the storage location for the project data. In the "Project Path" box, activate the "<DR>:\Projects" path you loaded. Enter the name of your new project in the "Project Name" box. The entry in the "Project Name" box is updated at the same time in the "New Subfolder" box. To finish, click the "Create" button to have WinCC create a new path with all of the required project data under the path that you selected. Note: If you want to change the project type of an existing project, use the Project Properties ("General Information" tab). WinCC Manual 1-7 Siemens Hardware

18 Control Center After the project data have been created, the Control Center opens up with the new project file. You can adapt this project file to your own special requirements. 1-8 WinCC Manual

19 08.97 Control Center 1.6 Summary The following terms have a special meaning within the Control Center: Multi-User System (Client-Server) Menu Bar Toolbar Project Window Feedback Documentation Project Navigation Window Project Components Computer Tag Management Communication Drivers Channel Unit Connections Process Tags and Internal Tags Tag Groups Data Types Editor Alarm Logging User Administrator Text Library Report Designer Global Scripts Tag Logging Graphics Designer Data Windows Pop-Up Menus Terms/Abbreviations WinCC Manual 1-9 Siemens Hardware

20 Control Center Menus of the Control Center The Menu Bar contains all of the commands available in the Control Center. These commands are arranged logically in groups and assigned to different menus. To execute a command, open the appropriate menu, click on the command, and, if necessary, set the parameters in the dialog box which opens. If you have not yet opened a project, only the following menu items and icons are available to you: If you have already opened a project, the following menu items and icons are available to you: 1-10 WinCC Manual

21 08.97 Control Center 1.8 Toolbar The Toolbar has the following structure: These icons make it possible for you to carry out actions more quickly. You do not need to select your way through the menu until you reach the required function. As an example, look at the steps for creating a new project file: How to Create a New Project: In the Toolbar, click on the icon. or Click on "New" in the "File" menu. You can find more information about this example under "File" "New". The following icons are available to you: "File" "New" "File" "Open..." "File "Activate "File "Activate "Edit" "Cut" "Edit" "Copy" "Edit" "Paste" "View" "Large Icons" "View" "Small Icons" "View" "List" "View" "Details" "Edit" "Properties" "Help" "Find " WinCC Manual 1-11 Siemens Hardware

22 Control Center Pop-Up Menus The pop-up menus are a very important and useful means of help within the Control Center. You receive these menus for each selected object within the project window. You need only hit the right mouse button to open the pop-up menus. For example, you receive the following window when you select the "Computer" object and hit the right mouse button. The "Search " and "Properties" menu items are offered for every object. The other menu items depend on which object is selected. In this example, the pop-up menu for the project component "Computer" was opened Feedback Documentation For the Control Center, a predefined system print job exists within the Report Designer for the feedback documentation. All configured computers, tags, and connections are printed out by means of this print job or displayed on the screen. The following project data are output by means of the feedback documentation: Computer Computer name Computer type Tag management Tag name Server or Client Data type (user data type) Connection (name of the logical connection) Channel (communication driver) Channel unit (channel unit of the communication driver used) Connections Connections (name of the logical connection) Unit (channel unit of the communication driver used) Parameters (current parameters of the channel unit) 1-12 WinCC Manual

23 08.97 Control Center How To......Print the Feedback Documentation for the Control Center: Use the "File" "Print Feedback Doc..." menu command to print the current project settings. or 1. Double click in the project navigation window on the "Editor" project component to view a list of all of the installed editors. 2. Click on the "Report Designer" editor. 3. Click on "Print Job" to view all of the available system print jobs in the project data window. 4. Click the right mouse button on the Documentation Control Center. 5. In the pop-up menu that appears, select the "Print Print Job" item to start the system print job for the feedback documentation of the Control Center....View the Feedback Documentation for the Control Center on the Screen: Use the "File" "Preview Feedback Doc" menu command to view the current project settings on the screen directly. or 1. Double click in the project navigation window on the "Editor" project component to view a list of all of the installed editors. 2. Click on the "Report Designer" editor. 3. Click on "Print Job" to view all of the available system print jobs in the project data window. 4. Click the right mouse button on the entry Feedback Documentation Control Center. 5. In the pop-up menu that appears, select the "Print Preview" command to display the system print job for the feedback documentation of the Control Center on the screen. WinCC Manual 1-13 Siemens Hardware

24 Control Center WinCC Manual

25 08.97 Control Center 2 The Menu Description of the Control Center 2.1 File Menu New Use the "New" menu item to open a dialog window in which you can open a new project. How to Create a New Project: 1. Click on the icon in the Toolbar or Click on "New" in the "File" menu. or Use the keystroke combination "Ctrl + N." 2. You have the following four options when creating a new project. Single User System Multi-User System with server utilities Project Wizard 3. You can also open an existing project. Opening an existing project This example shows you the dialog window for creating a new project. 4. Click on "OK." 5. This selection opens a window entitled "Create New Project" in which you can enter all of the declarations required for your new project. WinCC Manual 2-1 Siemens Hardware

26 Control Center Creating a New Project How to Create a New Project: Box Project Name New Subfolder Folder Project Path Drive Explanation Enter the name of your new project in this location. WinCC suggests that you use the same name for "New Subfolder." Select the folder in which your "New Subfolder" is to be loaded. The path under which your project is stored is displayed here. Select the drive on which your new project is to be stored. This example shows you the "Create New Project" dialog window. 2-2 WinCC Manual

27 08.97 Control Center How to Map a Network Drive: Box Drive Path Reconnect at Logon Value/Meaning Use this value to connect a drive letter to the network drive path. Here you can enter the path of the enabled folder to which you want to establish a connection. Normally, you have to enter the path in the following format: \\Computername\Foldername This setting allows to you specify that the network drive connection is reestablished every time the system starts up. If the setting is active, it is represented by the icon Open You can open an existing project using the "Open..." menu item. How to Open an Existing Project: 1. Click on "Open " in the "File" menu. or Click on the icon in the Toolbar. or Use the keystroke combination "Ctrl + O." 2. Select the drive as well as the folder and the desired file name. 3. Click the "Open" button. Note: Generally, only the program-related files (file name extension *.MCP) are listed. WinCC Manual 2-3 Siemens Hardware

28 Control Center Close Use the "Close" menu item to close the open project and remove it from the screen. How to Close a Project: Click on "Close" in the "File" menu. This selection closes all of the project-related files. The Control Center remains open and you can open and edit another project Activate Use the "Activate" menu item to trigger the Start/Stop of the process control (runtime) of the current project. This menu allows you to switch between the process control and configuration. If you activate the run-time module, this is noted within the "File" menu in the following manner: A check mark is in front of the "Activate" menu item The name of the current project is identified with the term "Active" within the Control Center title bar. Note: You can also activate/deactivate a project with the buttons and from the toolbar. How Can You Start a Configured Picture (Graphics Designer) Automatically When WinCC (Control Center) Starts? If you make the following settings, the run-time module of the Control Center as well as an existing picture in the Graphics Designer are started automatically when the WinCC program starts. 1. Within the "Computer" project component, activate the Properties of the Computer and switch to the Graphics Runtime tab. Enter the desired start picture in the "Start Picture" box. or Use the "Find" button to find the desired start picture and link to it. 2. Open the Startup tab and activate the "Graphics Runtime" box. This box is active as a default. 3. Use the "File" "Activate" menu item to start the Control Center run -time module. Note: The run-time modules of a computer with an active check box in the Start-up List are started when you activate a project. 2-4 WinCC Manual

29 08.97 Control Center Behavior of the WinCC System following the "Activation" of a Project: When you have activated a project, you cannot delete configured tags or connections. If you attempt to, the "Delete an Object" message window appears. This window informs you that you cannot delete an object within an active project. Behavior of WinCC while exiting Runtime: If you exit WinCC while a project is still activated, this project will be activated again if you start WinCC the next time. If you hit the key combination <Strg> + <Shift> while the Control Center is loading, you can halt the project activation. WinCC will then start with the configuration system. Note: The key combination for halting the activation of a project works for a single user system and for the server of a multi-user system, but not for the clients of a multi-user system Print Feedback Documentation Use the "Print Feedback Documentation" menu item to print the current project settings. Note: The functions of the feedback documentation use the system print job "@Documentation Control Center." This print job is located in the Control Center in the Project Navigation Window under "Editor" "Report Designer" "Print Job." View Feedback Documentation Use the "View Feedback Documentation" menu item to print the current project settings. Note: The functions of the feedback documentation use the system print job "@Documentation Control Center." This print job is located in the Control Center in the Project Navigation Window under "Editor" "Report Designer" "Print Job." Exit Use the "Exit" menu item to exit the Control Center. This command closes all of the files of the open projects. How to Exit a Project: Select "File" "Exit" in the menu bar and the "OK" button in the "Exit Control Center" dialog window. This selection closes all of the project-related files. During this phase, the storage process is displayed in the "Exit Control Center" window. WinCC Manual 2-5 Siemens Hardware

30 Control Center Shut Down Use the "Shut Down" menu item to exit the Control Center and shut down Windows 95 or Windows NT or log on under another name. This menu item offers the following options: 2.2 Edit Menu Undo This is the shutdown window of the Control Center. How to Exit a Project and the Current Windows Session: Select "File" "Shutdown" in the menu bar. In the dialog window that opens, make the selection with which you want to exit Windows. When you then click on the "OK" button, all of the project-related files close and the system shuts down or switches to another state from which a different user can log on. Use "Undo" to take back the last command used. How to Undo the Last Command: Click on "Undo" in the "Edit" menu. or Use the keystroke combination "Ctrl + Z." 2-6 WinCC Manual

31 08.97 Control Center Cut Use the "Cut" menu item to remove objects from the project and place them on the Clipboard. The objects are stored on the Clipboard until a new "Cut" or "Copy" replaces them. Note: You can cut out objects that you highlight within the project data window. How to Cut Out Objects: 1. Highlight the objects you want to cut out. 2. Click on "Cut" in the "Edit" menu. or Click on the icon in the Toolbar. or Use the keystroke combination "Ctrl + X." Copy Use the "Copy" menu item to create copies of objects and store them on the Clipboard. The object is stored on the Clipboard until a new "Cut" or "Copy" replaces it. Note: You can copy objects that you highlight within the project data window. How to Copy Objects: 1. Highlight the objects you want to copy. 2. Click on "Copy" in the "Edit" menu. or Click on the icon in the Toolbar. or Use the keystroke combination "Ctrl + C." WinCC Manual 2-7 Siemens Hardware

32 Control Center Paste Use the "Paste" menu item to copy the contents of the Clipboard into your project. The contents of the Clipboard do not change. Note: You can only paste an object if you have copied it to the Clipboard. Therefore, you must cut or copy something within the Control Center in order to paste it in your project. If you used another tool (for example, Word or Excel) to export something to the Clipboard, you cannot paste that item. How to Paste Objects from the Clipboard: Click on "Paste" in the "Edit" menu. or Click on the icon in the Toolbar. or Use the keystroke combination "Ctrl + V." Delete Use "Delete" to delete the selected object. How to Delete Objects: Click on "Delete" in the "Edit" menu. or Use the keystroke "Del" Properties Use the "Properties" menu item to edit the contents of the properties of the current object. How to Edit the Properties of the Current Object: Click on "Properties" in the "Edit" menu. or Click on the or icon in the Toolbar. Open the pop-up menu by clicking the right mouse button and select the "Properties" menu item. 2-8 WinCC Manual

33 08.97 Control Center 2.3 View Menu Toolbar Use the "Toolbar" menu item to turn the Toolbar on and off depending on your need. How to Display/Hide the Toolbar: Click on "Toolbar" in the "View" menu. A check mark to the left of the "Toolbar" menu item shows that the Toolbar is active Status Bar Use the "Status Bar" menu item to turn the Status Bar on and off depending on your need. The Status Bar is displayed on the lower border of the Control Center main window. The left side shows general program information. For example, if you select "File" "New" with the mouse button, "Creates a new document" appears in that area of the Status Bar. Look of the Status Bar Within the Control Center: If you select a menu item or an icon on the Toolbar, a brief help text is displayed. The number of objects contained in each selected node within the project navigation window is displayed. This area displays the keyboard status: "CAPS" Caps Lock is active. "NUM" The numeric keypad, located on the right side of the keyboard, is active. "SCRL" Scroll Lock is active. WinCC Manual 2-9 Siemens Hardware

34 Control Center Note: If the keyboard status boxes are not visible, this is due to the current window size of the Control Center. You can make these boxes visible by enlarging the size of the window. You can change the window size by clicking on this box Large Icons How to Display/Hide the Status Bar: Click on "Status Bar" in the "View" menu. A check mark to the left of the "Status Bar" menu item shows that the Status Bar is active. Use the "Large Icons" menu item to display the icons at full size in the right side of the window. When you select this view, all of the objects within the data window are displayed as follows: This example shows you the objects within a connection. How to Change the Display of the Icons: Click on "Large Icons" in the "View" menu. or Click on the icon in the Toolbar. The icons are displayed in full size on the right side of the window WinCC Manual

35 08.97 Control Center Small Icons Use the "Small Icons" menu item to display the icons in miniature on the right side of the window. When you select this view, all of the objects within the data window are displayed as follows: This example shows you the objects within a connection. How to Change the Display of the Icons: Click on "Small Icons" in the "View" menu. or Click on the icon in the Toolbar. The icons are displayed in miniature on the right side of the window List Use the "List" menu item to display the icons in a list format on the right side of the window. When you select this view, all of the objects within the data window are displayed as follows: This example shows you the objects within a connection. How to Change the Display: Click on "List" in the "View" menu. or Click on the icon in the Toolbar. The icons are displayed in a list on the right side of the window. WinCC Manual 2-11 Siemens Hardware

36 Control Center Details Use the "Details" menu item to display the information on the right side of the window in a detailed format. The data window looks like the following picture when "Details" is selected: This example shows you the objects within a connection. How to Change the Display : Click on "Details" in the "View" menu. or Click on the icon in the Toolbar. The icons are displayed in a detailed list on the right side of the window Update Use the "Update" menu item to update the information within the project window. How to Update the Project Window Display: Click on "Update" in the "View" menu. or Use the function key <F5> WinCC Manual

37 08.97 Control Center 2.4 Editors Menu Editors Use this menu item to add additional menu items during runtime as long as this is supported by the DLL of the application. Example: This example shows you the currently connected editors. The application DLLs of the editors support this connection capability by means of the "Editors" menu item. Selecting and Activating Menu Items Under "Editors": 1. Click on "Editors" in the Menu Bar. 2. Select a menu item. 3. From the sub menu that opens, select the menu item you want to activate. Note: Every menu item within the "Editors" contains the "Open" menu item. Multiple menu items can be present. The available menu items correspond to the structure of the pop-up menu for each individual editor which is located in the Project Navigation Window under the "Editor" project components. WinCC Manual 2-13 Siemens Hardware

38 Control Center Tools Menu Language Note: This menu item is available only if you installed more than one language when you installed WinCC. Generally, WinCC provides the following three languages: German English French How to Activate a Specific Language: 1. Click on "Options" in the menu bar. 2. Select the "Language" menu item. 3. In the "Language" dialog, you can select the language with which you want to work from the list of installed languages. To do this, simply select the desired language and then click the "OK" button. This action activates the selected language WinCC Manual

39 08.97 Control Center Status of Driver Connections Use the "Status of Driver Connections" menu item to view current information about the run-time module. Note: In order to see the current run-time status, the run-time module must be activated. Use the "Activate" menu item in the "File" menu to determine whether the run-time module is active. How to Scan the Current Runtime Status: Click on "Status of Driver Connections" in the "Tools" menu. This action open the "Status - Logical Connections" window. The current logical connections and their current status are displayed in seven columns in this window. Column Name Status Error Tags Read Tags Written Read Requests Write Requests Explanation Name of the logical connection Status of the logical connection Number of errors which occurred in the logical connection Total number of tags read in the logical connection since the start of the project Total number of tags written in the logical connection since the start of the project Number of read requests of the logical connection still open. If there are no read requests, there is a 0 at this location. Any other number value shows you that there are read requests that have not been concluded. Each activated read request increases the counter by 1. If the read request is completed, the number is decreased by one. Number of write requests of the logical connection still open. If there are no write requests, there is a 0 at this location. Any other number value shows you that there are write requests that have not been concluded. Each activated write request increases the counter by 1. If the write request is completed, the number is decreased by 1. WinCC Manual 2-15 Siemens Hardware

40 Control Center This is the "Status - Logical Connections" window. Within this window, the seven columns provide an overview of the current status of the logical connections. How to Influence Updating of the Runtime Status: Box Name Update Cyclic Update Update Explanation Activates cyclic updating. The cycle interval is executed in steps of 250 ms. The standard value for the update is 1 s (4 x 250 ms). Use the up-down controls to adjust the time interval. You can enter a value between 4 and 99 in the text box. Up you do not select a cyclic update, you can use the "Update" button to execute a current update of all of the connections WinCC Manual

41 08.97 Control Center Status of Multi-User Operation Use the "Status of Multi-User System" menu item to view the current status of the multi-user system. This shows you, for example, which computers are currently accessing the project. The dialog window is divided into the two following tabs: Process Data Server Process Data Clients Note: You CANNOT edit the boxes in the individual tabs. In case of an error, the information here is very helpful for the WinCC hotline. The status of a multi-user system can also be viewed from the clients, but only the information pertaining to the client making the request will be displayed. The "Process Data Server" tab provides the following information: Area Name Supported Network Protocols UUID Network Endpoint Properties Meaning This list box contains all of the available network protocols. This abbreviation stands for Universal User Identification. A unique identifier for the entire project is displayed in this box. The network endpoint is assigned dynamically by the operating system. This box contains two values that are separated by a slash and have the following significance: The first value is the minimum number of threads that are running and the second value is the maximum number of threads that are running on the server. The "Process Data Clients" tab provides the following information about a special client. You can select the client by means of the drop-down list box. WinCC Manual 2-17 Siemens Hardware

42 Control Center Area Name UUID Meaning This abbreviation stands for Universal User Identification. A unique identifier for the entire project is displayed in this box. Network Protocol Network Address Network Endpoint This box displays the protocol that the client is using to communicate with the server. This box displays the 12-digit Ethernet address of the server network card to which a connection was made. The network endpoint is assigned dynamically by the operating system. Note: If you view the status of the multi-user system from a client, all the information pertaining to this client will be displayed. Information about the server and other clients can not be viewed. 2.6 Help Menu Contents Use the "Contents" menu item to access the global on-line help of the Control Center. This help window gives you access to all of the help topics for the entire WinCC system (projects and tools). How to Call Up the Global On-Line Help: Click on "Contents" in the "Help" menu. You can find more information on this procedure in the Windows 95 or Windows NT description WinCC Manual

43 08.97 Control Center Find Use the "Find " menu item to view the help text for a specific term. How to Find a Specific Term in On-Line Help: 1. Click on "Find " in the "Help" menu. The mouse pointer is changed by having a question mark attached. or Click the help button the Toolbar. or Use <Shift> + <F1> to activate the Help mode. 2. Click on the menu command, editing box, or the button about which you want further information. Note: Select the <Esc> key to exit Help mode Index Use the "Index" menu item to call up the index for the Control Center on-line help. A window with three tabs (contents, index, and find) opens. The last tab that was opened is the one that you see when you activate the menu item. How to Call Up the Index of On-Line Help: Click on "Index" in the "Help" menu. You can find more information on the procedure in the Windows 95 or Windows NT description Glossary Use the "Glossary" menu item to call up the glossary. How to Call Up the Glossary: Click on "Glossary" in the "Help" menu. You can find more information on the procedure in the Windows 95 or Windows NT description. WinCC Manual 2-19 Siemens Hardware

44 Control Center Using Help Use the "Using Help" menu item to receive information about how to use the on-line help. How to Find Out How to Use On-Line Help: Click on "Using Help" in the "Help" menu Tutorial Use the "Tutorial" menu item to start the interactive tutorial. This program teaches you to handle WinCC and provides a case example in which you can execute a project in its entirety. In this case example, you become familiar with all of the important points for creating a project. How to Start the Tutorial: Click on "Tutorial" in the "Help" menu About Control Center... Use the "About Control Center " menu item to receive detailed information about the Control Center. The information window contains the current version number and the copyright information. In addition, you can see a window segment with a list of all of the installed optional modules. How to Receive Further Information about the Control Center: Click on "About Control Center " in the "Help" menu WinCC Manual

45 08.97 Control Center 3 Project Description 3.1 General Information About Projects Structure of a Project in the Control Center: A project consists of multiple components which are directly dependent on each other. You can find the individual components of a project in the project navigation window. Editing/Viewing the Project Properties: If you want to view or edit the project properties, you must select the current project in the project navigation window. Then you must open the corresponding pop-up menu and select the "Properties " menu item or use the button in the Toolbar. The pop-up menu of the current project is displayed in the data window. WinCC Manual 3-1 Siemens Hardware

46 Control Center Project Properties How to Edit the Project Properties: 1. In the project navigation window, click the right mouse button on the project name which you can recognize by the *.MCP file extension. In the pop-up menu that then appears, click on the "Properties..." menu item. A dialog box with the following tabs appears: or Use the button in the Toolbar. 2. You can select among the three tabs in the "Project Properties" dialog box. The individual tabs have the following meaning: Tab General Information Update Cycles Hot Keys Explanation General project data. Set the project-related time interval for updating the process image. Assign a hot key to certain actions in the WinCC system. 3-2 WinCC Manual

47 08.97 Control Center "General Information" Tab How to Edit the "General Information" Tab: In the "General Information" tab, click on the box you want to edit. You can edit the boxes shown in the following table. The individual boxes have the following meaning: Box Name Type Creator Creation Date Changed By Last Change Version GUID Comment Explanation The current project type is displayed in this box. You can manage a project as a "Single-User System" or a "Multi-User System." Use this box to change the project type also. The name of the project creator is entered in this box. This name corresponds to the user name that the creator of a project under Windows 95 or Windows NT used to log on to the system. The date the project was created is entered in this box. This date corresponds to the system date on the computer on which the project was created. The name of the editor of the project is entered in this box. The date of the last change to the project is entered in this box. This date corresponds to the system date on the computer on which the project was edited. The number of the current project version is entered in this box. Alphanumeric characters can be used here. The project ID number is loaded in this box. A new number is created for each project. This identification is necessary for database handling. You can enter comments concerning the current project in this box. Alphanumeric characters can be used here. WinCC Manual 3-3 Siemens Hardware

48 Control Center This picture shows you the screen structure of the "General Information" tab "Update Cycle" Tab Note: The "Update Cycles" tab contains preset cycles and cycles you can define yourself. You can recognize the definable cycles by their standard identification "User Cycle n," where "n" corresponds to a range between 1 and 5. This means that you can assign a maximum of 5 definable user cycles. 3-4 WinCC Manual

49 08.97 Control Center How to Select a Preset Update Cycle: 1. Click on the "Update Cycles" tab. 2. Select the update cycle required for your project. 3. Use the "OK" button to apply the selected update cycle. This example shows you some of the possible preset update cycles. How to Set an Update Cycle You Can Define Yourself: 1. Click on the "Update Cycles" tab. 2. Select one of the available (maximum 5) user cycles. (The user cycles you can define yourself are located at the end of the list). This example shows you the user cycles you can define yourself. The boxes that can be edited are located on the lower border. 3. If you want to change the name, click on the left box (for example, "User Cycle 1" as seen in the example) and change the name. WinCC Manual 3-5 Siemens Hardware

50 Control Center If you want to change the update cycle, click on the right box (for example, "2000" as shown in the example) and change the value. You can enter a value from 100 ms to ms (100 ms to 10 hr) in this box. The value entered is rounded up to the next value divisible by 100 (for example, if you enter 2111, the value is rounded up to 2200 when you hit a key). 5. Use the "OK" button to apply the selected update cycle. Note: If a user cycle is changed while the project is running in run time, the change does not affect the run time. The change does not take effect until you DEACTIVATE/ACTIVATE the project "Hot Keys" Tab How to Use the "Hot Keys" Tab to Assign a Hot Key to Specific Actions: 1. Click on the "Hot Keys" tab. 2. In the "Actions" box, select the action to be activated with a hot key. 3. The current hot key is displayed in the "Previously Assigned" box. If no hot key has been assigned, this box contains "None." In order to assign a hot key to the selected action, proceed as follows: a. Click on the "Previously Assigned" box. b. Now use the keys that you want to correspond to the hot key (for example <Shift> + <F6> or <Alt> + <F4>). 4. Use the "Assign" button. You can activate the selected action with the hot key you set. Note: With the hot keys for the "Log-on" and "Log-off" actions, you can log on to or off of a running run-time module. For example, if you assign the keystroke combination <Ctrl> + <Alt> + <N> to the "Logon" action, you must log on to a running run -time module using this keystroke combination. You can fine more detailed information in the manual for the " User Administrator." If you want to execute the "Hardcopy" action by means of a hot key, you must connect the "PrtScr.exe" program in the Computer Startup ListComputer "Startup" tab (Control Center). The "PrtScr.exe" program is located in the "\bin" path of WinCC (for example "C:\WinCC\Bin or C:\Siemens\WinCC\Bin"). 3-6 WinCC Manual

51 08.97 Control Center 4 Project Window in the Control Center 4.1 General Information about the Project Window When you start the Control Center and open a project, a project window opens. This window is divided into two halves. The left side contains the project navigation window, in which you can move easily through your entire project. Each position change in the project navigation window causes a direct change in the data window which is located on the right side of the screen. This window corresponds to the "Project Window." The "Project Navigation Window" is on the left side and the "Data Window" is on the right. 4.2 Project Navigation Window The Project Navigation Window is Structured as Follows: There is a main node in the project navigation that is represented by the project name, for example,. Use the or buttons to display or hide the levels beneath the project name. A project consists of the following components: Note: You can edit the properties of each project component by selecting the "Properties " menu item in the appropriate pop-up menu. Each project component can contains additional sub-items. WinCC Manual 4-1 Siemens Hardware

52 Control Center Project Component Computer Tag Management Data Types Editor Explanation All of the workstations and servers that are assigned to a project are managed in this area. All channels, logical connections, process and internal tags, and tag groups are managed in this area. All data types and the tags assigned to them are mirrored in this area and are even available to other channels. All of the available editors are listed in this area. This includes the graphic system (Graphics Designer), action processing (Global Scripts), message system (Alarm Logging), measurement value archiving and editing ( Tag Logging), report system (Report Designer), user authorization ( User Administration), and the text library (Text Library). These modules are all a part of the WinCC system but they do not all have to be installed. 4-2 WinCC Manual

53 08.97 Control Center You Can Move As Follows in the Project Navigation Window: Note: You can use the mouse or the keyboard to move in the project navigation window. Keystroke commands correspond to those used in Windows 95 or Windows NT (for example, arrow keys, plus and minus on the numeric keypad). Each change in position triggers an immediate update of the data window on the right side of the screen. 1. In the project navigation window, click on the or button to display or hide an additional level. 2. Double click on a name in order to open or close an additional level (for example, double click on "Computer" to open the next level). This picture shows you the structure of the project navigation window. How to Set the Optimal Window Width for the Project Navigation Window: 1. Position the mouse pointer on the dividing line between the project navigation window and the data window. The mouse pointer changes to. 2. Click the left mouse button and hold it down while moving the mouse to the left or right. This action changes the width of the window. 3. When you release the mouse button, the display is changed to the new window width. This example shows you the window dividing line that separates the project navigation window from the data window. WinCC Manual 4-3 Siemens Hardware

54 Control Center Data Window You Can Move as Follows in the Data Window: Note: You can use the mouse or the keyboard to move in the data window. Keystroke commands correspond to those used in Windows 95 or Windows NT (for example, arrow keys). 1. Double click on a name to open a list or an object. 2. When you select an object and click the right mouse button, the pop-up menu of the object opens. 3. If you click the right mouse button in an empty area of the window, the pop-up menu for the corresponding list element in the project navigation window opens. This example shows the data window. The Data Window is Constructed as Follows in the "Large Icons," "Small Icons," and "List" Views: Each object is represented by the corresponding icon and its name. The following example shows the computer objects in the "Large Icons" view: 4-4 WinCC Manual

55 08.97 Control Center The Data Window Has the Following Structure in the Details View: Note: Use the "Name," "Type," "Parameter," and "Last Change" buttons to sort the contents of the data window in rising or falling order. The data window is divided into the following four columns: Project Component Explanation Name Type This column displays name of the object, a tag, or a file. (The file name is assigned to a specific editor). This column displays the type of the object. For example, in the case of a computer, this column could contain "Server." With tags, the data type of each tag is displayed. Parameter Last Change This column displays the address descriptions for external tags: for example, the data block number (DB) and the data word address (DW). In the case of internal tags, "Internal Tags" is entered in this location. This column displays the date and time of the last change. WinCC Manual 4-5 Siemens Hardware

56 Control Center How to Set the Optimal Column Width for the Details View: There are two ways to change the column width: Position the mouse pointer on the dividing line between the individual columns. The mouse pointer then changes to. Click the left mouse button and hold it down. If you move the mouse to the left or right, the column width changes. When you release the mouse button, the display changes to the new column width. Position the mouse pointer on the dividing line between the individual columns. The mouse pointer then changes to. If you double click the left mouse button, the display changes to the optimal column width. The optimal column width is determined by the column with the longest value. This example shows the dividing lines in the Details view in the data window. 4-6 WinCC Manual

57 08.97 Control Center 5 Project Components in the Control Center 5.1 General Information About Project Components What are Project Components, Where Are They Located, and How Can You Edit Them? A project is made up of the following components: Computer Tag Management Data Types Editor The project navigation window lists all of the components that belong to the project. How to Edit or View the Properties of Each Project Component: Select the project component whose properties you want to edit and click the right mouse button. In the pop-up menu that then appears, select the "Properties..." menu item. 5.2 Structure of the "Computer" Project Component The "Computer" Project Component Has the Following Structure: There are no sub-items to this component. All of the computers assigned to the project are listed in the data window. This example shows you a configured computer of the server type under the "Server Computer" project component. WinCC Manual 5-1 Siemens Hardware

58 Control Center Properties of the "Computer" Project Component How to Edit the Properties of the "Computer" Project Component: 1. In the project navigation window, click the right mouse button on "Computer." In the pop-up menu that then appears, select the "Properties..." menu item. 2. In the "Computer List Properties" dialog box, you can start the following actions: Use the "Delete" button to delete the selected computer from your current project management. In order to be able to edit a project, at least one computer must be available. Use the "Properties" button to edit the properties of the selected computer. Use the "OK" button to apply all of the settings you make, or use "Cancel" to reject those settings. Use the "Help" button to access the help system. 5.3 Structure of the "Tag Management" Project Component This Is the Way the "Tag Management" Project Component Is Structured: This component can have multiple sub-items. Communication drivers, which manage process tags, and "Internal Tags" are managed in the "Tag Management" project component. 5-2 WinCC Manual

59 08.97 Control Center This example shows you six installed communication drivers and their channel units under the "Tag Management" project component. Each communication driver can be made up of the following sub-items: 1 to n channel units 1 to n logical connections. All tag groups and tags in the logical connection are managed and displayed in this area. 1 to n tag groups. All tags of the tag group in the logical connection are displayed and managed in this area. 1 to n independent tags. All tags that do not belong to a tag group are managed and displayed in this area. This example shows you the "SIMATIC S5 Ethernet Layer 4" communication driver with the "S5-Transport (CP1413-1)" channel unit as well as its logical connections and tag groups Properties of the "Tag Management" Project Component How to Edit the Properties of the "Tag Management" Project Component: 1. In the project navigation window, click the right mouse button on "Tag Management." In the pop-up menu that then appears, select the "Properties..." menu item. 2. You can start the following actions in the "Properties List of the Communication Driver" dialog box: Use the "New" button to link new communication drivers to your current project management. Use the "Delete" button to delete the selected communication driver from your current project management. You can also delete multiple communication drivers at once. Use the "OK" button to apply all of the settings you make, or use "Cancel" to reject those settings. Use the "Help" button to access the help system. WinCC Manual 5-3 Siemens Hardware

60 Control Center Structure of the "Data Types" Project Component This Is the Way the "Data Types" Project Component Is Structured: All the standard data types are listed in this area. When you select a data type, the data window displays all of the tags related to the project. This example shows you all of the available data types under the "Data Types" project component. This example shows you all of the "Signed 16-Bit Value" data type tags related to the project under the "Data Types" project component. 5-4 WinCC Manual

61 08.97 Control Center Creating New Tags: You can also use the "Data Types" project component to create new tags. To create a new tag, proceed as follows: 1. In the project components, select the data type for which you want to create a new tag. 2. Open the pop-up menu and select the "New " menu item. 3. The "Tag Assignment" dialog window opens. 4. Select the connection or tag group in which you want to include the new tag. You can also create a new internal tag. 5. After you click on the "OK" button, the "Tag Properties" dialog window opens in which you can make the settings for the new tag. 6. Once you have made all the settings, click on the "OK" button to create the new tag. Note: In the "Tag Assignment" dialog window, you can recognize the configured tag groups by the icon in front of the connection. 5.5 Structure of the "Editor" Project Component This Is the Way the "Editor" Project Component Is Structured: All installed editors are listed in this area. During the WinCC system installation, you can determine which editors you will find in this area. The following picture shows you all of the available editors, the default editors as well as the optional editors: WinCC Manual 5-5 Siemens Hardware

62 Control Center This example lists all of the editors of the WinCC system listed under the "Editors" project component. The "Report Designer" area offers the following additional functions: The "Global Script" area offers the following additional functions: Properties of the "Editor" Project Component How to Edit the Properties of the "Editor" Project Component: 1. In the project navigation window, click the right mouse button on "Editor." In the pop-up menu that then appears, select the "Properties..." menu item. 2. You can start the following actions in the "Properties of Tools" dialog box: Use the "New" button to link new editors to your current project management. Use the "Delete" button to delete the selected editor from your current project management. Use the "Properties" button to view or edit the properties of the selected editor. Use the "OK" button to apply all of the settings you make, or use "Cancel" to reject those settings. Use the "Help" button to access the help system. 5-6 WinCC Manual

63 08.97 Control Center 6 Computer 6.1 General Information About a Computer General Information About the "Computer" Project Component: Use the "Computer" project component to manage all of the computers that can access the current project. You can configure each computer individually. Structure of the "Computer Properties" Dialog Window: The "Computer Properties" dialog window is divided into the following four tabs: Click the "OK" button to apply all of the settings you made, or click "Cancel" to reject them. Use the "Help" button to access the help system. 6.2 "General Information" Tab You Can Edit the Following Boxes in the "General Information" Tab: This example shown you the "General Information" dialog window within the "Computer Properties" window. WinCC Manual 6-1 Siemens Hardware

64 Control Center Input Box "Computer Name" How to Edit the "Computer Name" Input Box: Click on the "Computer Name" box and enter the name of the computer that should have access to the WinCC System. Note: You can determine which computers are accessible over the network by using the Windows 95 Explorer. All of the current computers are listed in the "Network Environment" node Selection Box "Computer Type" Use this selection box to assign a specific function within the current project to the selected computer. Box Name Server Client Engineering Station Explanation Central computer for data storage and global management of the WinCC system. A "Client" is also identified as a workstation. The Control Center is loaded locally on each of these computers. This computer serves in a purely monitoring capacity. No projects can be edited on this computer. How to Edit the Selection Box: Simply click on the appropriate selection box. An active selection box is displayed with the icon. If the selection box was deactivated, the icon appears. Note: If a server exists already and you click on the "Server" selection box for a configured client computer, the "Select Process Data Server" message window appears. This window notifies you that a server exists. If you click "OK" in the message window, the selected client computer is changed to a server and the current server (the name of the server is in the message window) changes to a client. This change does not take effect until after you restart WinCC. 6-2 WinCC Manual

65 08.97 Control Center List Box "Client-Server List" 6.3 "Startup" Tab This list box displays all of the configured client and server computers. Depending on whether you select the client or server computer type, the title of the list box changes to the following: Client "Name of the Server" Server "Names of the Clients" List Box "Name of the Server": Sets the location of the data source (project database) for each client List Box "Name of the Clients": The client list displays the clients that have access to the server and to the data source (project database) available there. Meaning of the Buttons of the List Boxes: Select a server in the server list and edit the list using the following buttons: Use the "Up" and "Down" buttons to change the sequence of the servers in the server list. Use the "Properties" button to edit the properties of the selected computer. Use the "Add" button to add a new computer to the current list. Use the "Delete" button to delete a computer from the current list. General Information about the "Startup" Tab: You can enter programs in the "Startup" tab that are to be loaded automatically when the Control Center starts. You can activate the default WinCC run-time modules or include programs from other manufacturers. The following two window areas within the "Startup" tab are arranged above and below each other: 1. Sequence When Starting the WinCC Runtime Module This window contains a list of all of the default WinCC run-time modules. 2. Additional Tasks/Applications The applications that are not in the "Sequence When Starting the WinCC Runtime Module" window but must still be started are managed in this window. WinCC Manual 6-3 Siemens Hardware

66 Control Center This example shows you the "Startup" tab within the "Computer Properties" dialog window. In this example, all of the WinCC run -time modules have been activated and three applications were connected in the "Additional Tasks/Applications" list box. Note: When you create a new project, only the Graphics Run Time is activated in the startup list Sequence When Starting the WinCC Runtime Module General Information About this Selection Window: This window lists all of the default WinCC runtime modules. You cannot delete any of the available modules in this list box. You can only activate or deactivate these modules. When you activate a module, the selected module is loaded automatically when the WinCC system starts. As a default, all of the modules are activated and started automatically. How to Activate/Deactivate a Specific Runtime Module: You must click on the box in front of the module name to activate or deactivate the run-time module. You can recognize an activated module by the icon in front of the corresponding module name. 6-4 WinCC Manual

67 08.97 Control Center How to Assign an Optional Parameter to a Specific Runtime Module: In the list box, select a WinCC run -time module. Click on the "Edit" button to open the "Edit Application" dialog window. You can edit the "Parameters" input field in this dialog. Note: In the "Edit Application" dialog window, you can only edit the "Parameters" input field Additional Tasks/Applications This example shows you that the "Parameters" field is the only area that can be changed for the "Report Run Time." General Information About This Selection Window: The applications that are not available in the "Sequence When Starting the WinCC Runtime Module" window but should be started are managed in this window. WinCC Manual 6-5 Siemens Hardware

68 Control Center Structure of the Selection Window: In this dialog window, you can enter the required settings for the applications you want to add. The input fields in this dialog have the following meaning: Field Name Application Parameters Working Directory Meaning Enter the exact name of the desired application in this input field. You must also input the exact path for this application. The simplest way to enter a new application is to use the "Browse " button. After you click on the "Browse " button, the "Find File" dialog window opens. As a default, this dialog searches along the paths on which you installed the WinCC system (for example, C:\WinCC\Bin). You should enter executable programs in this field. You can recognize such programs by the *.EXE, *.COM, or *.BAT file extensions. Note: If you do not make any entries in this field and then click the "OK" button, an error message window appears. Use this input field to enter the required parameters of the application. You can determine which parameters can be entered here by looking in the manual for the corresponding application. Use this input field to set the working directory in which all of the files necessary for the application are located. The simplest way to enter a working director in this input field is to use the "Browse " button. After you click on the "Browse " button, the "Working Directory" dialog window opens in which you can find the required working directory and transfer it to the "Working Directory" input field. 6-6 WinCC Manual

69 08.97 Control Center Project Folder Click on the "Project Folder" check box to set the current project folder as the working directory. Normally, all of the project folders are arranged within the path on which you installed the WinCC system (for example: <Drive>:\WINCC\BIN\). When you have activated the project folder, this is identified with the icon. The correct syntax for the Control Center project folder is as follows: "<Drive>:\WINCC\BIN\<Projectname>" Window Size In this example, the project folder is "<Drive>:\WINCC\BIN\HJB1". Note: If you have activated this check box, the "Working Directory" input field and the "Browse " button are gray and you cannot use them. Use this field to set the window size of the application at the start of the program. You can select from the following three settings: Minimized Standard Maximized Under Windows 95, the program is loaded as an icon on the Start Bar. Under Windows NT, the program is loaded as an icon on the screen. Under Windows 95 and Windows NT the program is displayed in the full screen mode which is standard for the program. This value is also the default setting. Under Windows 95 and Windows NT the program is displayed in full screen view after it starts. WinCC Manual 6-7 Siemens Hardware

70 Control Center This example shows you the "Add Application" dialog window. Editing the "Additional Tasks/Applications" List Box: Select an application from the list box. Use the "Up" and "Down" buttons to set the start sequence of the applications. Use the "Add" button to add a new application to the list box. Use the "Remove" button to delete a selected application from the list box. Use the "Edit" button to edit the settings of the selected application. 6-8 WinCC Manual

71 08.97 Control Center 6.4 "Parameters" Tab You can affect the following "Parameters": These settings affect the working method of the selected computer. Box Key Combinations Lock Ctrl+Alt+Del Alt+TAB Ctrl+Esc Alt+Esc Priority Normal High Language Setting at Run Time Start Information Explanation You cannot close any running application in Windows 95. You cannot open the Windows NT security window in Windows NT. You cannot switch to another application. In Windows 95, you cannot open the Start menu. In Windows NT, you cannot open the task list. You cannot switch to another application. With this setting, the program occupies the processor until a program with a higher priority requests access. With a high priority, the program occupies the processor by itself. Other programs cannot access the processor until the program releases it. This location displays the current language setting for the configuration of the run-time module. Use this value to open a new properties window within the "Parameters" tab. This only functions when the program to be connected does not support any MFC functions. If the connected program supports this possibility, the "Edit" button is enabled for activation. WinCC Manual 6-9 Siemens Hardware

72 Control Center If you "Lock a Key Combination," this action is identified by the icon. Depending on which "Priority" you select, it is identified by the icon. This example shows you the "Parameters" tab within the "Computer Properties" dialog window WinCC Manual

73 08.97 Control Center 6.5 "Graphics Run Time" Tab Use this tab to change the appearance as well as the edit mode for the run-time module. Structure of the "Graphics Run Time" Tab: Box Project File Start Picture Meaning This box displays the name of the current project file. You cannot edit this box. Use this box to set a start picture. You can use one of the following means to enter the file name of the start picture: Enter the name of the desired start picture manually. Click on the "Browse " button to open the "Start Picture" dialog. Use the dialog to connect the start picture you want to use. Note: In the "Start Picture" box, you must enter the name of the start picture without a path specification. The path of the start picture consists of the project path and "GraCS," for example, "C:\WinCC\Bin\<Projectname>\GraCS." If you use the "Browse " button to connect a start picture, you must be sure that the start picture is located in the default folder "GraCS." Window Attributes Title Border Maximize Minimize Click on this box to view the title bar of the window. Click on this box to provide the window with a border. Click on this box to view the button for maximizing the window. Click on this button to view the window. button for minimizing the WinCC Manual 6-11 Siemens Hardware

74 Control Center Full Screen Scroll Bar Status Bar Adapt Picture Turn Off ALT-F4 Change Size Move Minimize Maximize Close Optimized View Click on this box to open the window in full screen mode. This mode uses the entire screen for the display. Click on this box to assign a scroll bar to the window. Click on this box to assign a status bar to the window. Click on this box to adapt the configured window structure to the current window size. Click on this box to deactivate the <Alt> + <F4> hot key for closing the window. Click on this box to deactivate the ability to use the window border to change the size of the window Click on this box to make it impossible to move the window. Click on this box to deactivate the window. button for minimizing the Click on this box to deactivate the window. button for maximizing the Click on this box to deactivate the window. button for closing the Click on this box to turn off the optimized screen structure for the individual elements. This means that the window structure occurs in steps. You can recognize the step-by-step window structure when the affected element flashes. If this box is not active, the window is not updated in steps. This is achieved by displaying the entire contents of the window at once (external screen construction within the RAM and then copied to the video storage) WinCC Manual

75 08.97 Control Center Hot Keys To create a hot key, select the box you want by clicking the mouse on it. Then use the key or keystroke combination you want to assign to the box. The selected box displays the hot key you choose as a series of keystrokes, for example, Switch Windows Tab Order / Alpha Cursor Run Time Cursor Cursor Control: Keys By configuring picture windows within a picture, you can set specific window areas. To switch among the individual window areas, define a hot key here. By configuring within picture windows in the "Graphics Designer" picture, you can group specific areas into a "Tab Order Sequence" or an "Alpha Cursor Sequence." You can define a hot key for switching between the "Tab Order Sequence" and "Alpha Cursor Sequence." All buttons are grouped within a "Tab Order Sequence." All I/O fields are grouped within an "Alpha Cursor Sequence." Depending on which sequence is active, you can use the "Tab" key to move from one box to another. Use the "Tab" key to move to the next box or use "Shift" + "Tab" to move to the previous box. Use this box to set a hot key to turn the Tab Order or Alpha Cursor sequence that is currently active on or off. Use these boxes to set the keys or keystroke combinations for moving the cursor UP, DOWN, LEFT, and RIGHT. If you also activate one or more of the Ctrl, Alt, or Shift boxes, you must use the corresponding key or keys in addition to the key you set in the UP, DOWN, LEFT, and RIGHT boxes. If you activate the "Start at Startup" box, the cursor control for the configured keys is turned on each time the run -time system starts. WinCC Manual 6-13 Siemens Hardware

76 Control Center Cursor Control: Behavior Normal Normal without Rollback Expanded Use these selection boxes to influence the behavior of the cursor control in run time: This box is activated as a default and has the following effect on the cursor control: Once the cursor reaches the outer fields of the cursor group, the cursor will jump to the first field within the row in which the cursor has been moved, if you continue to use the cursor keys that move the cursor outwards. If you activate this box, the cursor control behaves as follows: Once the cursor reaches the outer fields of the cursor group, it will remain at that position, even if you continue to use the cursor keys that move the cursor outwards. If you activate this box, the cursor control behaves as follows: You can move the cursor up to the outside positions. Once the cursor reaches the farthest position, the cursor moves to the first position within the next row or column. This example shows the "Graphics Run Time" tab within the "Properties of a Computer" dialog WinCC Manual

77 08.97 Control Center How to Activate/Deactivate the Individual Selection Boxes within "Window Attributes" and "Turn Off": Simply click on the appropriate selection box. An active selection box is identified by the identified by the icon. If the selection box has been deactivated, it is icon. The settings in the "Cursor Control" selection box have the following effect on the behavior of the cursor in run time: Selection box "Normal": (default setting): You can move the cursor up to the outermost positions. Once the outermost position has been reached, the cursor will jump to the first position within the current row or column. Selection box "Normal without Rollback": You can only move the cursor to the outside positions. Once the outside position has been reached, the cursor will remain at that t position. The cursor can then be moved only towards the inside. WinCC Manual 6-15 Siemens Hardware

78 Control Center Selection box "Expanded": You can move the cursor to the outside positions. Once the outside position has been reached, the cursor jumps to the first position within the next row or column. How to Apply or Reject the Settings You Made: You can accept all of the settings into your project by clicking the "OK" button or reject them by clicking "Cancel." Use the "Help" button to access the help system WinCC Manual

79 08.97 Control Center 7 Communication Drivers 7.1 General Information About the Communication Drivers What Are Communication Drivers? A communication driver is the interface between a subordinate PLC system and WinCC. Which Communication Drivers Does the WinCC System Contain? You can find out which communication drivers WinCC supports by looking in the Channel DLL, Communication Drivers manual. The Channel DLL, Communication Drivers manual provides you with the following information: The prerequisites that you need to access process tags by means of a PLC The general procedures for connecting to external tags An introduction to the specific configuration of the Channel DLL (communication driver) How To Install New Communication Drivers: 1. In the Project Navigation Window, click the right mouse button on the project component "Tag Management" or Click the right mouse button on an empty screen area in the data window. 3. In the pop-up menu, select the "Add New Driver..." menu item. The "Open the Communication Driver" dialog window opens. The Pop-Up Menu of the Communication Driver Contains the Following Items: Menu Item Find... Delete Properties Explanation Use this menu item to set and start a search action within the entire WinCC system. Delete the selected communication driver. View the properties of the selected communication driver. WinCC Manual 7-1 Siemens Hardware

80 Control Center Properties of a Communication Driver How to View the Properties of a Communication Driver: Note: You can only view the properties of a communication driver. You cannot edit these values. 1. In the Project Navigation Window, double click on the project component "Tag Management." You then receive a list of all of the installed communication drivers. 2. From the list of available communication drivers, select the communication driver whose parameters you want to view. 3. Open the corresponding pop-up menu. 4. Select the "Properties" menu item. This selection opens a window entitled "Communication Driver Properties" where you can view the current values of the selected driver. Structure of the "General Information" Tab: You can only view the "General Information" tab. The following areas are displayed in this tab: Area Explanation Type Path Size Units The name of the channel file is displayed here (for example, SIMATIC S5 ETHERNET TF). The type of communication driver is displayed here. The default display is Channel DLL. The name of the channel file is displayed here (for example, SIMATIC S5 ETHERNET TF.CHN). The size of the channel DLL is displayed here. The size of the channel DLL is displayed in kilobytes and bytes (for example, 135 Kbytes ( bytes). The number of channel units in the channel file is displayed here (for example, the SIMATIC S5 ETHERNET TF.CHN channel DLL contains 2 units). 7-2 WinCC Manual

81 08.97 Control Center 7.3 Accepting a New Communication Driver How to Connect a Communication Driver to Your Project Management: 1. Click the right mouse button on "Tag Management" in the Project Navigation Window. or Click the right mouse button on an empty screen area in the data window. 2. The pop-up menu appears, from which you select "Add New Driver." 3. This selection opens a dialog window which lists all of the channel files currently available to you. The standard file extension for the channel files is "*.CHN." 4. Use either of the following steps to select the communication driver you want to connect to your project: Double click on the file name to copy the file to your project management. Select the file you want to connect. This selection transfers the file name to the "File Name" input box. Then, you click the "Open" button to transfer the selected communication driver to your project management. Error Message at an Attempt to Reload an Already Installed Communication Driver: When you attempt to connect an already installed " SIMATIC S5 ETHERNET TF.CHN " communication driver to your project, a message window appears to let you know that the communication driver is already installed. Each communication driver can only be installed once. 7.4 Deleting a Communication Driver How to Delete a Communication Driver: If you want to delete a communication driver, you must proceed as follows: 1. Within the data window, select the object you want to delete. 2. Use the right mouse button to open the corresponding pop-up menu and select "Delete." 3. In the "Delete One Object" dialog window which then appears, click on the "Yes" button. The selected object, any sub-objects it may contain, and all of the values contained in them are deleted. WinCC Manual 7-3 Siemens Hardware

82 Control Center WinCC Manual

83 08.97 Control Center 8 Channel Unit 8.1 General Information about a Channel Unit What is a Channel Unit? A WinCC channel is implemented as a Windows DLL and dynamically linked to the system. Each WinCC channel represents access to a specific type of connection parameter with a specific protocol (for example, the SIMATIC S5 Ethernet TF channel helps to access a SIMATIC S5 with the TF protocol). One channel DLL can support multiple channel units of the same type. For example, the SIMATIC S5 Ethernet TF channel DLL can be driven with a SINEC-H1 unit (CP1413) as well as with a SINEC- L2unit (CP5412), in some cases at the same time. The WinCC data manager requests process values at run time from the remote PLC through the logical connection. The channel unit carries out the communication steps necessary for requesting the process values by means of the channelspecific connection and thus provides the WinCC data manager with process values. The data which are read in are stored as a process image in the RAM of your computer. All WinCC components access this process image. A channel unit is linked to the communication driver and, therefore, cannot be deleted or installed separately. Logical connections, tag groups, and tags can be assigned to a channel unit. How to Open the Pop-Up Menu of the Channel Unit: 1. In the Project Navigation Window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers. 2. In the Project Navigation Window or the data window, click the right mouse button on the channel unit for which you want to open the pop-up menu. 3. A corresponding pop-up menu appears. The structure of the menus can be different. WinCC Manual 8-1 Siemens Hardware

84 Control Center What Does the Pop-Up Menu of the Channel Unit Contain? Menu Item New Connection... System Parameters Find... Paste Properties Explanation Use this menu item to set up a new logical connection. Use this menu item to open the dialog window for the system parameters of the channel unit, for example, bus parameters or device names. This menu item is not supported by all of the channel units. Use this menu item to set and start a search action within the entire WinCC system. This menu item is not available for a channel unit. Use this menu item to view or edit the properties of the selected channel unit. 8.2 "System Parameters" Dialog How to View/Edit the System Parameters of a Channel Unit: The structure of the "System Parameters" dialog window can differ from channel unit to channel unit. This dialog window can be made up of one or more tabs whose structure depends on the channel unit used. System parameters can be set for the channel units of the " SIMATIC S5 Ethernet Layer 4" communication driver. How to View/Edit the System Parameters of a Channel Unit: 1. In the Project Navigation Window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the desired communication driver. This action provides a list of all of the available channel units. 3. Select the desired channel unit and click the right mouse button. 4. In the pop-up menu that appears, select the "System Parameters" menu item. 5. The "System Parameters" dialog window opens. In this dialog window, you can edit or view the system parameters of the selected channel unit. 8-2 WinCC Manual

85 08.97 Control Center System Parameters for the " SIMATIC S5 Ethernet Layer 4" Communication Driver Structure of the "System Parameters" Dialog Window for the Channel Units of the "SIMATIC S5 Ethernet Layer 4" Communication Driver: The "System Parameters" dialog window consists of two tabs, "Device Names" and "Transport Parameters." You can affect the values in the tabs by means of the following boxes: Box Change Name Value/Explanation You can change the device name displayed in bold and make it fit your current needs. The device name corresponds to the name of the network software. This example shows the system parameters of an SIMATIC S5 Ethernet Layer 4 communication driver ("Device Names" tab) WinCC Manual 8-3 Siemens Hardware

86 Control Center You can affect the values of the "Transport Parameters" tab by means of the following boxes: Box PDU Size Setup Attempts Infinite Quantity Duration of Send Repetitions Infinite Time Job Management Acknowledgment Time Value/Explanation Here you can enter the maximum length of a data package to be transmitted. You can use one of the following values: The system constantly tries to set up the connection. Set the maximum number of setup attempts. A data package that is not acknowledged is constantly repeated. Set the maximum number of repetition attempts for an unacknowledged data package. Specify the time in seconds to wait for an answer from the remote PLC. This example displays the system parameters of a SIMATIC S5 Ethernet Layer 4 communication driver ("Transport Parameters" tab). 8-4 WinCC Manual

87 08.97 Control Center 8.3 "Channel Unit Properties" Dialog Structure of the "Channel Unit Properties" Dialog Window: The dialog window contains two tabs with the following contents: Tab Connections General Information Contents Create new connections and edit existing connections in the "Connections" tab. Enter general settings affecting the logical connection in the "General Information" tab "Connections" Tab How to Edit the "Connections" Tab: Select the logical connection you want to edit in the "Connections" tab. Use the "New" button to create a new logical connection. Use the "Delete" button to delete the selected logical connection. Use the "Properties" button to edit the properties of the selected logical connection. This example shows the "Connections" tab. WinCC Manual 8-5 Siemens Hardware

88 Control Center "General Information" Tab How to View the General Properties of the Selected Channel Unit: Click on the "General Information" tab in the selected channel unit. All of the properties of the selected channel unit appear. You can determine what the current channel unit is in the "Name" box. Note: You can only view the boxes in the "General Information" tab. These boxes show you which functions are supported by the channel unit and which ones are not. All active functions are designated by the icon. The individual boxes have the following meaning: Box Name Byte Access Bit Access Watchdog Start-up Signal Reentrant Explanation A channel unit uses this property bit to determine if it has write access to the remote PLC. Writing to byte addresses means that the low byte of a word can be written without changing the high byte and vice versa. A channel unit uses this property bit to determine if it has write access to bits. Writing bits means that a bit can be written to the memory range of the remote PLC without changing other bits. A channel unit uses this property bit to determine if it executes its own watchdog monitoring. When the unit executes its own watchdog monitoring, it guarantees that the communication channel and the remote PLC are ready to communicate. A channel unit uses this property bit to determine if it automatically shares a start-up with the remote PLC. When an automatic start-up signal is selected, a channel shares its start-up with the remote PLC. A channel unit uses this property bit to determine if its API functions are reentrant. A reentrant channel unit guarantees that its API functions can be called simultaneously by multiple threads of the WinCC data manager. If synchronization of the threads by means of operating system resources (such as semaphores or events) is necessary, the channel unit performs the synchronization. If the channel unit is not reentrant, the WinCC data manager synchronizes its threads. 8-6 WinCC Manual

89 08.97 Control Center Remote Tag On-Line Connections On-Line Tags A channel unit uses this property bit to determine if it can access tags that are configured in the remote PLC. Tags that are configured by the remote PLC are identified by means of their names. The channel unit is capable of providing these names to the WinCC data manager when necessary. A channel unit uses this property bit to determine if it can register additional logical connections if it was started in RUNTIME mode. If a channel unit is started in RUNTIME mode and if this property bit is set, newly configured logical connections are registered immediately with the channel unit by means of the WinCC data manager. The channel unit loads the corresponding specific connection so that the logical connection is capable of operating immediately. A channel unit uses this p roperty bit to determine if it can register additional WinCC tags at run time. WinCC Manual 8-7 Siemens Hardware

90 Control Center Register a Tag Own Properties Uses MFC Intel Byte Order A channel unit uses this property bit to determine if it wants WinCC tags that are assigned to the logical connection of the unit to be registered during the initialization phase. A channel unit uses this property bit to determine if it contains its own configuration of internal configuration values. A channel unit uses this property bit to determine if the channel-specific dialogs are implemented by means of Visual C++ and MFC or standard Windows tools. A channel unit uses this property bit to determine if process data in the remote PLC are in INTEL byte order. Four property bits are set in this example ("General Information" tab). 8-8 WinCC Manual

91 08.97 Control Center 9 Connection 9.1 General Information About a Connection What is a Logical Connection? A logical connection describes the interface between the automation system and the WinCC data manager. How to Create a New Logical Connection: 1. In the Project Navigation Window, double click on the "Tag Management" project component which provides you with a list of all installed communication drivers. 2. In the Project Navigation Window, double click on the desired communication driver. This action opens up a list of all available channel units. 3. Select the desired channel unit and click the right mou se button. 4. In the pop-up menu that appears, select the "New Connection..." menu item. This selection opens the "Connection Properties" dialog window. Here you can load new tag groups and tags, and set the name of the new connection. 9.2 "Connection Properties" Dialog Structure of the "Connection Properties" Dialog Window: The dialog window consists of at least four tabs with the following contents: Tab General Information Groups Tag Connection Contents Enter general properties that affect the logical connection in the "General Information" tab. Create tag groups in the "Groups" tab. Groups can be used for a better organization of tags. Create tags in the "Tag" tab. These tags are not assigned to a group. The structure of this tab depends on the communication driver used. There can be different "Connection" tabs for each communication driver. Even the name of the tab can be different. Use the "OK" button to apply all of the settings you made or use "Cancel" to ignore them. Use the "Help" button to access the help system. WinCC Manual 9-1 Siemens Hardware

92 Control Center "General Information" Tab How to Edit the "General Information" Tab: In the selected channel unit, click on the "General Information" tab. The system displays the general properties of the selected logical connection. The individual boxes have the following meaning: Box Name Unit Server List Value/Meaning Enter the name of the logical connection here. This name cannot have been used within your project at this point. The standard name provided is "New Connection" which you must replace with a unique name. Select the desired channel unit in this box. Each client uses the server list to determine the location of the data source. You determine the location of the data source for the run-time module with the sequence of the individual servers within the server list. Use the "Up" and "Down" buttons to change the sequence of the servers in the server list. Use the "Add" button to add a new server to the current server list. Use the "Remove" button to delete a server from the current server list. This is a picture of the "General Information" tab. 9-2 WinCC Manual

93 08.97 Control Center "Groups" Tab What is a Group? A group combines all of the tags which have a logical connection to each other. For example, you can create the following groups: This table serves as an example only: Group CPU Furnace Presses Digital I/O Analog I/O Explanation This group combines all of the tags that access the same CPU. This group combines all of the tags that access a furnace. This group combines all of the tags that access the presses. This group combines all of the tags that access all the digital I/Os. This group combines all of the tags that access all the analog I/Os. This table should serve only as an example. You Can Execute the Following Actions within the "Groups" Tab: Use the"new" button to create a new tag group. Use the "Delete" button to delete the selected tag group. Use the "Properties" button to edit the properties of the selected tag group. This picture displays the "Groups" tab. WinCC Manual 9-3 Siemens Hardware

94 Control Center "Tag" Tab What is a Tag? WinCC tags are the central element for accessing process values. Within a WinCC project, they receive a unique name and a data type, among other things. A logical connection is assigned to a WinCC tag. This connection determines which channel delivers the process values to the tags using which connection. The WinCC tags are stored in a project-wide data base. When a WinCC machine starts, all of the tags belonging to a project are loaded and the corresponding run-time structures are set up. You Can Execute the Following Actions Within the "Tag" Tab: Use the "New" button to create new tags. Use the "Delete" button to delete the selected tag. Use the "Properties" button to edit the properties of the selected tag Channel-Specific Tab This picture shows the "Tag" tab. What Does the Channel-Specific Tab Contain? The structure of the channel-specific tab can be different from channel unit to channel unit. Not only are the contents of the tabs sometimes different, even the name of the tab can change. You can find additional information about the structure of this or other tabs in the Channel DLL, Communication Drivers manual. 9-4 WinCC Manual

95 08.97 Control Center 10 Tags 10.1 General Information About Tags What is a Tag? WinCC tags are the central element for accessing process values. Within a WinCC project, they receive a unique name and a data type. A logical connection is assigned to a WinCC tag. This connection determines which channel delivers the process values to the tags using which connection. The WinCC tags are stored in a project-wide data base. When a WinCC machine starts, all of the tags belonging to a project are loaded and the corresponding run-time structures are set up. A WinCC tag describes a data cell that is unique within a project and the rules to be followed when this data cell is accessed. For an application, access to the tag utilities of the data manager is transparent. This means an application needs no information about the source or the target of the tags. Generally, the data manager differentiates between the following two types of tags: Internal Tags No addressing in the PLC layer. External Tags Assignment to a logical connection and address in the PLC layer. Within the external tags, there is a special form of tags known as "Raw Data Tags." Note: Tag names and groups must have unique names throughout the project. The following naming conventions exist: No key words (per C conventions) like float, type, main, void No special or connecting characters + - / & " [ ] * { }. : < > ; = \ No empty spaces There is no differentiation between upper case and lower case letters concerning the naming of tags. WinCC Manual 10-1 Siemens Hardware

96 Control Center Within a Project, Tags Can Be Created and Managed at the Following Locations: Within a connection, as independent tags Within a connection, as tags in a tag group Within the internal tags, as independent tags Within the internal tags, tags as tags in a tag group Within the project component "Data types," new tags in connections, tag groups, or as internal tags Updating Tags with Process Values The WinCC server data manager is responsible for providing the WinCC tags with process values at run time. The data manager provides the process values to its local WinCC tags as well as to the tags that belong to the corresponding WinCC client. The data manager transfers the tags to be updated to their logical connection and thus to the appropriate channel. The channel executes the necessary communication steps by means of its process bus in an optimized manner. This way, a minimum of data traffic is necessary on the process bus in order to assign values to all tags. Logical Connection Channel List of Tags to Be Updated Within a Project, Tags Can be Cut, Copied, or Deleted in the Following Manner: The procedure for cutting, copying, or deleting tags is the same for independent tags, tags within a group, and internal tags. Standard Data Types for Tags: You must assign one of the standard data types to each tag. The tag is stored under this data type in the data manager WinCC Manual

97 08.97 Control Center 10.2 Independent Tags in a Connection How to Create a New Independent Tag: Note: If the connection does not exist yet, you must first create the logical connection and create the new tag during this process. 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the communication driver you want to view a list of all available channel units. 3. Double click on the desired channel unit to view a list of all available logical connections. 4. Select the desired logical connection and click the right mouse button. 5. In the pop-up menu that appears, select the "New Tag..." menu item. 6. This selection opens the "Tag Properties" dialog box in which you can create a new tag. How to Edit an Existing Independent Tag: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the communication driver you want to view a list of all available channel units. 3. Double click on the desired channel unit to view a list of all available logical connections. 4. Select the desired logical connection. 5. All of the existing tags appear in the data window. Select the desired tag and click the right mouse button. In the pop -up menu that then appears, select the "Properties" menu item. or Double click on the desired tag in the project data window. 6. This action opens the "Tag Properties" dialog box in which you can edit existing tags. WinCC Manual 10-3 Siemens Hardware

98 Control Center Tags in a Tag Group within a Connection How to Create a New Tag within a Tag Group: Note: If there is no tag group within a connection, you must first create a tag group. 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the communication driver you want to view a list of all available channel units. 3. Double click on the desired channel unit to view a list of all available logical connections. 4. Double click on the desired logical connection to view a list of all available tag groups. 5. Select the desired tag group and click the right mouse button. 6. In the pop-up menu that then appears, select the "New Tag..." menu item. 7. This selection opens the "Tag Properties" dialog box in which you can create a new tag. How to Edit an Existing Tag within a Tag Group: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the communication driver you want to view a list of all available channel units. 3. Double click on the desired channel unit to view a list of all available logical connections. 4. Double click on the desired logical channel unit to view a list of all available tag groups. 5. Select the desired tag group. 6. In the project data window, select the desired tag and click the right mouse button. In the pop-up menu that then appears, select the "Properties" menu item. or In the project data window, double click on the desired tag. 7. This selection opens the "Tag Properties" dialog box in which you can create a new tag WinCC Manual

99 08.97 Control Center 10.4 Internal Tags for an Entire Project How to Create a New Internal Tag for an Entire Project: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. In the project navigation window, select the "Internal Tags" project component and click the right mouse button. 3. In the pop-up menu that then appears, select the "New Tag..." menu item. 4. This selection opens the "Tag Properties" dialog box in which you can create a new tag. How to Edit Existing Internal Tags for an Entire Project: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Click on the "Internal Tags" project component to view a list in the project data window of all available tag groups and independent tags. 3. In the project data window, select the desired tag and click the right mouse button. In the pop-up menu that then appears, select the "Properties" menu item. or In the project data window, double click on the desired tag. 4. This selection opens the "Tag Properties" dialog box in which you can edit an existing tag. WinCC Manual 10-5 Siemens Hardware

100 Control Center Internal Tags in a Tag Group for an Entire Project How to Create a New Internal Tag for an Entire Project within a Tag Group: Note: If there is no tag group in the internal tags, you must first create a tag group. 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Click on the "Internal Tags" project component to view a list of all available tag groups. 3. Select a tag group and click the right mouse button. 4. In the pop-up menu that then appears, select the "New Tag..." menu item. 5. This selection opens the "Tag Properties" dialog box in which you can create a new tag. How to Edit an Existing Internal Tag for the Entire Project within a Tag Group: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Click on the "Internal Tags" project component to view a list of all available tag groups. 3. Select a tag group and click the right mouse button. 4. In the pop-up menu that then appears, select the "Properties" menu item. or In the project data window, double click on the desired tag. 5. This selection opens the "Tag Properties" dialog box in which you can edit an existing tag WinCC Manual

101 08.97 Control Center 10.6 "Tag Properties" Dialog Structure of the "Tag Properties" Dialog Box: Note: If the selected tag was created by means of an external program and if a creator identifier (see Open Developers Kit (ODK)) was used in its creation, it is possible that you can view the tag within WinCC but not edit it (read only). If this is the case, you can recognize it by the following: The dialog window title includes a "read only" entry and the "OK" button is displayed in gray and cannot be used. You can only use the "Cancel" button. You can neither delete nor rename tags with this kind of creator identifier. You can only copy these tags which makes the copied tag completely editable again. The dialog box contains two tabs with the following contents: Tab General Information Limits/Reporting Contents General settings for the tag are set in the "General Information" tab. The structure of this tab differs with "Process Tags" and "Internal Tags." You can set the limits of the tag and set triggers for reporting certain events in the "Limits/Reporting" tab. Use the "OK" button to apply all of the settings you made, or use "Cancel" to reject those settings. Use the "Help" button to access the help system "General Information" Tab for Process Tags What Are External Tags? In the WinCC system, external tags are also known as process tags. External tags are linked to a logical connection. In order to mirror the address information of the various PLC systems, external tags consist of a general section which contains information like name, type, and limit values, and a connection-specific section whose interpretation depends on the logical connection. The data manager always provides the specific section of external tags to the applications in a text format. WinCC Manual 10-7 Siemens Hardware

102 Control Center Structure of the "General Information" Tab for Process Tags: The individual boxes have the following meaning: Box Name/Button Name Data Type Length Explanation Enter a unique tag name here. Data type of the tags. The selected data type also influences whether you can edit the fields "Adapt Format and "Address, as well as the settings in the "Limits/Reporting" tab. You can change the length of the selected data type in this box. This box can only be edited for the "Text Tag..." data type. Address "Select Button Adapt Format Linear Scaling Process Value Range Value Range of Tag The structure of this window depends on the data type and the selected channel-dll. This field can be edited via the "Select button. This button opens the "Address Properties dialog window. You can set the precise address of the tag, in the subordinate PLC, in this dialog. You can convert the selected data type to another data type (for example, data type "Unsigned 8-Bit Value" adapt format to "CharToUnsignedByte"). The first format marks the data type in WinCC, the second format the data type in the PLC. If this option is selected, the value range of a process tag can be mapped to an internal value range, which allows you to scale the process tag. Set the process value range of the tags to be scaled by entering the minimum and maximum values. Set the value range in which the process tag will be mapped by entering the minimum and maximum values WinCC Manual

103 08.97 Control Center Note: Since several editors internally do not work with the tag names but with the tag identifiers, a renaming of a tag would cause, for example, a loss of an already configured message assignment. If the renaming of a tag is unavoidable, the individual messages in "Alarm Logging should be exported before the renaming and be imported afterwards to link them to the tag again. If you change the data type of an already existing external tag, its defined address will be deleted. This action is justified by the fact that a data type change also changes the PLC address "General Information" Tab for Internal Tags What Are Internal Tags? Internal tags do not have an address in the supporting PLC systems and are therefore provided by the data manager inside WinCC for the entire network. Internal tags are used to store general information like current date, time, current layer, and currently logged in user. In addition, internal tags enable a transparent data exchange between applications in order to implement interprocess communication in a centralized and optimized manner. Structure of the "General Information" Tab for Internal Tags: The individual boxes have the following meaning: Box Name/Button Name Explanation Enter a unique tag name in this box. Update for Entire Project Update on Local Computer Data Type Length The "Internal Tag" is updated for the entire project. The "Internal Tag" is only updated in the local workstation. Data type of the tags. The selected data type also affects whether you can edit the "Limits/Reporting" tab or the "Adapt Format" and "Address Parameters" boxes in the "General Information" tab. You can change the length of the selected data type in this box. This box can only be edited for the "Text Tag..." data type. WinCC Manual 10-9 Siemens Hardware

104 Control Center "Limits/Reporting" Tab Structure of the "Limits/Reporting" Tab: The individual boxes have the following meaning: Box Name High Limit Low Limit Start Value Substitute Value Explanation Set the maximum high limit for the tags. If the high limit value is exceeded, the value is NOT written. In this event, only a message flag is set. Set the minimum low limit for the tags. If the low limit value is exceeded, the value is NOT written. In this event, only a message flag is set. Presettings with a start value, for example, for counters. If an event makes the implementation of a substitute value necessary, select this option WinCC Manual

105 08.97 Control Center Use Substitute Value At High Limit At Low Limit As Start Value For Connection Errors Generate Report Entry For Violation of High Limit Violation of Low Limit Conversion Error Write Access Applications Write Access Process Determine when the substitute value is used. When the value of the high limit is exceeded, the substitute value should be used. When the value falls below the low limit, the substitute value should be used. The substitute value is used as the start value, for example, when a connection is interrupted. When connection errors occur, the substitute value should be used. Determine at which event a report entry is generated. Tag value of the high limit is exceeded. Tag value falls below the low limit. An error occurs when converting the data type. For each application, report the write access to a tag. For each process, report the write access to a tag. WinCC Manual Siemens Hardware

106 Control Center Cutting, Copying, or Deleting Tags To cut, copy, or delete tags, you must select the tags first. You can select tags using either of the two procedures described below. How to Select Multiple Tags in a List: 1. Highlight the first tag. 2. Click the left mouse button. 3. Press the <CTRL> key and hold it down. 4. Then select the next tags and click the left mouse button on each one. 5. When all of the tags you want to select are highlighted, release the <CTRL> key WinCC Manual

107 08.97 Control Center How to Select a Block of Contiguous Tags in a List: 1. Highlight the first tag. 2. Click the left mouse button. 3. Press the <SHIFT> key and hold it down. 4. Then select the last tag in the list that you want to highlight and click the left mouse button. 5. Release the <SHIFT> key. All of the tags between the two selected tags are highlighted. How to Cut, Copy, or Delete One or More Tags: Note: The task sequence for cutting, copying, or deleting is the same for all tags. 1. First, you must select the tags as described above. You can find the tags under the "Tag Management" project component. Within this node, the tags can be in groups, can be assigned to internal tags, or can be executed as independent tags. 2. Highlight the tags and click the right mouse button. 3. In the pop-up menu that then appears, select the "Cut," "Copy," or "Delete" menu item. If you want to paste one or more cut or copied tags: 4. Select the target area to which you want to copy the selected tags. 5. Click the right mouse button in the data window. 6. Select "Paste" in the pop-up menu that appears. 7. This action copies all of the selected tags to the target area. You must be aware of the following fact in this copy procedure: Each of the copied tags receives a sequential number as is shown in the following examples. The "BinVarS5TF" tag is renamed to "BinVarS5TF_1" after it is copied. The "BinVarS5TF_1" is renamed to "BinVarS5TF_2" after it is copied. The "BinVarS5TF_DB70" is renamed to "BinVarS5TF_DB71" after it is copied. WinCC Manual Siemens Hardware

108 Control Center If you want to delete one or more tags: 4. The "Delete nnn Object(s)" window appears if you select the "Delete" pop-up menu item. Click the "Yes" button in this window. The selected tags are deleted. (nnn is the number of selected objects). Note: If a tag is copied and pasted, configured tag assignments, like a message assignment, might not be copied. This example shows you the tags before the copy procedure. This example shows the tags after the copy procedure WinCC Manual

109 08.97 Control Center 10.8 Standard Data Types The following data types are available in WinCC: You must assign one of the following data types to each of the configured tags. The assignment of the data type to a tag is executed while creating new tags. The data type of a tag is independent of the tag type (for example, process or internal tag). Certain data types can be converted to other data types in WinCC by adapting the format. The following table contains all of the standard data types. Note: If you change the data type of an already existing external tag, its defined address will be deleted. This action is justified by the fact that a data type change also changes the PLC address. Data Types Binary Tag Signed 8-Bit Value Unsigned 8-Bit Value Signed 16-Bit Value Unsigned 16-Bit Value Signed 32-Bit Value Unsigned 32-Bit Value Floating-Point Number 32-Bit IEEE 754 Floating-Point Number 64-Bit IEEE 754 Text Tag 8-Bit Character Set Text Tag 16-Bit Character Set Raw Data Type Text Reference Structure Types Format Adaptable No Yes Yes Yes Yes Yes Yes Yes Yes No No No No No "Binary Tag" Data Type Description of the Data Type: This data type accepts both the TRUE or FALSE states. This data type is one byte long and corresponds to a bit. When you create a new tag of this type, the "Length" and "Adapt Format" boxes are inactive and are therefore gray in the display. Note: You cannot adapt the format of this data type. WinCC Manual Siemens Hardware

110 Control Center "Signed 8-Bit Value" Data Type Description of the Data Type: This data type is one byte long and has a sign (plus or minus). When you create a new tag of this type, the "Adapt Format" box displays "CharToSignedByte" as the standard. The number range is between -128 and Note: You can adapt the format of this data type. Adapt Format Number Range CharToSignedByte -128 to +127 (no conversion) CharToUnsignedByte 0 to 127 CharToUnsignedWord 0 to 127 CharToUnsignedDword 0 to 127 CharToSignedWord -128 to +127 CharToSignedDword -128 to +127 CharToMSBByte -127 to +127 CharToMSBWord -127 to +127 CharToMSBDword -128 to +127 CharToBCDByte 0 to 99 CharToBCDWord 0 to 127 CharToBCDDword 0 to 127 CharToSignedBCDByte -9 to +9 CharToSignedBCDWord -128 to +127 CharToSignedBCDDword -128 to +127 CharToExtSignedBCDByte -79 to +79 CharToExtSignedBCDWord -128 to +127 CharToExtSignedBCDDword -128 to +127 CharToAikenByte 0 to 99 CharToAikenWord 0 to 127 CharToAikenDword 0 to 127 CharToSignedAikenByte -9 to +9 CharToSignedAikenWord -128 to +127 CharToSignedAikenDword -128 to +127 CharToExcessByte 0 to 99 CharToExcessWord 0 to 127 CharToExcessDword 0 to 127 CharToSignedExcessByte -9 to +9 CharToSignedExcessWord -128 to +127 CharToSignedExcessDword -128 to WinCC Manual

111 08.97 Control Center "Unsigned 8-Bit Value" Data Type Description of the Data Type: This data type is one byte long and does not have a sign. When you create a new tag of this type, the "Adapt Format" box displays "ByteToUnsignedByte" as the standard. The number range is between 0 and 255. Note: You can adapt the format of this data type. Adapt Format Number Range ByteToUnsignedByte 0 to 255 (no conversion) ByteToUnsignedWord 0 to 255 ByteToUnsignedDword 0 to 255 ByteToSignedByte 0 to 127 ByteToSignedWord 0 to 255 ByteToSignedDword 0 to 255 ByteToBCDByte 0 to 99 ByteToBCDWord 0 to 255 ByteToBCDDword 0 to 255 ByteToAikenByte 0 to 99 ByteToAikenWord 0 to 255 ByteToAikenDword 0 to 255 ByteToExcessByte 0 to 99 ByteToExcessWord 0 to 255 ByteToExcessDword 0 to 255 WinCC Manual Siemens Hardware

112 Control Center "Signed 16-Bit Value" Data Type Description of the Data Type: This data type is two bytes long and has a sign (plus or minus). When you create a new tag of this type, the "Adapt Format" box displays "ShortToSignedWord" as the standard. The number range is between and Note: You can adapt the format of this data type. Adapt Format Number Range ShortToSignedWord to (no conversion) ShortToUnsignedByte 0 to 255 ShortToUnsignedWord 0 to ShortToUnsignedDword 0 to ShortToSignedByte -128 to +127 ShortToSignedDword to ShortToMSBByte -127 to +127 ShortToMSBWord to ShortToMSBDword to ShortToBCDByte 0 to 99 ShortToBCDWord 0 to 9999 ShortToBCDDword 0 to ShortToSignedBCDByte -9 to +9 ShortToSignedBCDWord -999 to +999 ShortToSignedBCDDword to ShortToExtSignedBCDByte -79 to +79 ShortToExtSignedBCDWord to ShortToExtSignedBCDDword to ShortToAikenByte 0 to 99 ShortToAikenWord 0 to 9999 ShortToAikenDword 0 to ShortToSignedAikenByte -9 to +9 ShortToSignedAikenWord -999 to +999 ShortToSignedAikenDword to ShortToExcessByte 0 to 99 ShortToExcessWord 0 to 9999 ShortToExcessDword 0 to ShortToSignedExcessByte -9 to +9 ShortToSignedExcessWord -999 to +999 ShortToSignedExcessDword to WinCC Manual

113 08.97 Control Center "Unsigned 16-Bit Value" Data Type Description of the Data Type: This data type is two bytes long and has no sign. When you create a new tag of this type, the "Adapt Format" box displays "WordToUnsignedWord" as the standard. The number range is between 0 and Note: You can adapt the format of this data type. Adapt Format Number Range WordToUnsignedWord 0 to (no conversion) WordToUnsignedByte 0 to 255 WordToUnsignedDword 0 to WordToSignedByte 0 to 127 WordToSignedWord 0 to WordToSignedDword 0 to WordToBCDByte 0 to 99 WordToBCDWord 0 to 9999 WordToBCDDword 0 to WordToAikenByte 0 to 99 WordToAikenWord 0 to 9999 WordToAikenDword 0 to WordToExcessByte 0 to 99 WordToExcessWord 0 to 9999 WordToExcessDword 0 to WordToS5Counter 0 to 999 WinCC Manual Siemens Hardware

114 Control Center "Signed 32-Bit Value" Data Type Description of the Data Type: This data type is four bytes long and has a sign (plus or minus). When you create a new tag of this type, the "Adapt Format" box displays "LongToSignedDword" as the standard. The number range is between and Note: You can adapt the format of this data type. Adapt Format Number Range LongToSignedDword to (no conversion) LongToUnsignedByte 0 to 255 LongToUnsignedWord 0 to LongToUnsignedDword 0 to LongToSignedByte -128 to +127 LongToSignedWord to LongToMSBByte -127 to +127 LongToMSBWord to LongToMSBDword to LongToBCDByte 0 to 99 LongToBCDWord 0 to 9999 LongToBCDDword 0 to LongToSignedBCDByte -9 to +9 LongToSignedBCDWord -999 to +999 LongToSignedBCDDword to LongToExtSignedBCDByte -79 to +79 LongToExtSignedBCDWord to LongToExtSignedBCDDword to LongToAikenByte 0 to 99 LongToAikenWord 0 to 9999 LongToAikenDword 0 to LongToSignedAikenByte -9 to +9 LongToSignedAikenWord -999 to +999 LongToSignedAikenDword to LongToExcessByte 0 to 99 LongToExcessWord 0 to 9999 LongToExcessDword 0 to LongToSignedExcessByte -9 to +9 LongToSignedExcessWord -999 to +999 LongToSignedExcessDword to LongToS5Timer WinCC Manual

115 08.97 Control Center "Unsigned 32-Bit Value" Data Type Description of the Data Type: This data type is four bytes long and has no sign. When you create a new tag of this type, the "Adapt Format" box displays "DwordToUnsignedDword" as the standard. The number range is between 0 and Note: You can adapt the format of this data type. Adapt Format Number Range DwordToUnsignedDword 0 to (no conversion) DwordToUnsignedByte 0 to 255 DwordToUnsignedWord 0 to DwordToSignedByte 0 to 127 DwordToSignedWord 0 to DwordToSignedDword 0 to DwordToBCDByte 0 to 99 DwordToBCDWord 0 to 9999 DwordToBCDDword 0 to DwordToAikenByte 0 to 99 DwordToAikenWord 0 to 9999 DwordToAikenDword 0 to DwordToExcessByte 0 to 99 DwordToExcessWord 0 to 9999 DwordToExcessDword 0 to DwordToS5Timer 10 to WinCC Manual Siemens Hardware

116 Control Center "Floating-Point Number 32-Bit IEEE 754" Data Type Description of the Data Type: This data type is four bytes long and has a sign (plus or minus). When you create a new tag of this type, the "Adapt Format" box displays "FloatToFloat" as the standard. The number range is e+38. Note: For every "Float To Dword" format adaptation, only the first seven places are considered. The Float data type only allows seven places. When you use an S7 connection the number range for the "Float To Float" adapt format is e+38. Adapt Format Number Range FloatToFloat e+38 (no conversion) FloatToUnsignedByte 0 to 255 FloatToUnsignedWord 0 to FloatToUnsignedDword 0 to e+09 FloatToSignedByte -128 to +127 FloatToSignedWord to FloatToSignedDword e+09 to e+09 FloatToDouble e+38 FloatToMSBByte -127 to +127 FloatToMSBWord to FloatToMSBDword e+09 to e+09 FloatToBCDByte 0 to 99 FloatToBCDWord 0 to 9999 FloatToBCDDword 0 to e+07 FloatToSignedBCDByte -9 to +9 FloatToSignedBCDWord -999 to +999 FloatToSignedBCDDword to FloatToExtSignedBCDByte -79 to +79 FloatToExtSignedBCDWord to FloatToExtSignedBCDDword e+07 to e+07 FloatToAikenByte 0 to 99 FloatToAikenWord 0 to 9999 FloatToAikenDword 0 to e+-07 FloatToSignedAikenByte -9 to +9 FloatToSignedAikenWord -999 to +999 FloatToSignedAikenDword to FloatToExcessByte 0 to 99 FloatToExcessWord 0 to 9999 FloatToExcessDword 0 to e+07 FloatToSignedExcessByte -9 to +9 FloatToSignedExcessWord -999 to +999 FloatToSignedExcessDword to FloatToS5Timer 10 to FloatToS5Float e WinCC Manual

117 08.97 Control Center "Floating-Point Number 64-Bit IEEE 754" Data Type Description of the Data Type: This data type is eight bytes long and has a sign (plus or minus). When you create a new tag of this type, the "Adapt Format" box displays "DoubleToDouble" as a standard. The number range is e+308 Note: With the "Double to Float" format adaptation, only the first seven places are considered. The float data type only allows seven places. Adapt Format DoubleToDouble Number Range e+308 (no conversion) DoubleToUnsignedByte 0 to 255 DoubleToUnsignedWord 0 to DoubleToUnsignedDword 0 to DoubleToSignedByte -128 to +127 DoubleToSignedWord to DoubleToSignedDword to DoubleToFloat e+38 DoubleToMSBByte -127 to +127 DoubleToMSBWord to DoubleToMSBDword to DoubleToBCDByte 0 to 99 DoubleToBCDWord 0 to 9999 DoubleToBCDDword 0 to DoubleToSignedBCDByte -9 to +9 DoubleToSignedBCDWord -999 to +999 DoubleToSignedBCDDword to DoubleToExtSignedBCDByte -79 to +79 DoubleToExtSignedBCDWord to DoubleToExtSignedBCDDword to DoubleToAikenByte 0 to 99 DoubleToAikenWord 0 to 9999 DoubleToAikenDword 0 to DoubleToSignedAikenByte -9 to +9 DoubleToSignedAikenWord -999 to +999 DoubleToSignedAikenDword to DoubleToExcessByte 0 to 99 DoubleToExcessWord 0 to 9999 DoubleToExcessDword 0 to DoubleToSignedExcessByte -9 to +9 DoubleToSignedExcessWord -999 to +999 DoubleToSignedExcessDword to DoubleToS5Timer 10 to DoubleToS5Float e+38 WinCC Manual Siemens Hardware

118 Control Center "Text Tag 8-Bit Character Set" Data Type Description of the Data Type: This data type is 0 to bit bytes long. When you create a new tag of this type, the "Adapt Format" box is inactive and appears gray. Note: You cannot adapt the format of this data type "Text Tag 16-Bit Character Set" Data Type Description of the Data Type: This data type has a variable length of 0 to bit words. When you create a new tag of this type, the "Adapt Format" box is inactive and appears gray. Note: You cannot adapt the format of this data type "Raw Data Type" Data Type Description of the Data Type: From a general point of view, a tag of the raw data type corresponds to a data message frame on the transport level. A tag of this type is not interpreted by the data manager. There is no limit to the length of this data type. When you create a new tag of this type, the "Length" and "Adapt Format" boxes are inactive and appear gray. Note: You cannot adapt the format of this data type WinCC Manual

119 08.97 Control Center "Text Reference" Data Type Description of the Data Type: You can load only INTERNAL tags in this data type. The tag created in this manner refers to an entry within the "Text Library" ("Text ID" box). Note: You cannot adapt the format of this data type. Assigning a Text ID Number: Activate the "Start Value" check box in the "Tag Properties" dialog window and enter the text ID number. The number you enter here must agree with the "Text ID" within the "Text Library." Creating a New Text Reference Tag: Use the following steps to create a new text reference tag: 1. In the Project Navigation Window, double click on the "Data Types" component to view a list of all data types. 2. Click the right mouse button on the "Text Reference" data type. 3. In the pop-up menu that appears, select the "New Text Reference Tag" menu item. 4. The "Tag Properties" dialog opens and you can edit the properties of the new text reference tag. WinCC Manual Siemens Hardware

120 Control Center "Structure Types" Data Type Description of the "Structure Types" Data Type: Use this data type to create a data structure that is oriented to your needs. You can combine different default data types with each other so that the new data structure forms a logical unit. Note: You cannot adapt the format of this data type. You can only adapt the format of individual data types within the data structure. You can only edit an existing data structure if you have not configured any tags with the data type. If you want to change an existing data structure, you must first delete the configured tags. The "Structure Properties" dialog window notifies you of the presence of a configured instance (tag) by means of the following text in the window title bar: "(Instances Still Present! Read Only)." This examples shows you the structure of the "NewStructure" data structure WinCC Manual

121 08.97 Control Center Creating a New Structure Type: Use the following steps to create a new structure type: 1. In the Project Navigation Window, double click on the "Data Types" project component to view a list of all data types. 2. Click the right mouse button on the "Structure Types" data type. 3. In the pop-up menu that appears, select the "New Structure Type " menu item. 4. The "Structure Properties" dialog window opens and you can create the structure of the data structure. Structure and Editing Possibilities within the "Structure Properties" Dialog Window: The dialog window consists of a tab ("General Information") that is divided into the following three areas: OS (Operator Station): The data structure is created in this area. You can connect a new data structure to the supported formats of a unit via the listbox "Use Formats from Unit. If you select a unit, the "Adapt Format listbox will only display formats supported by the selected unit. Each entry within the data structure can be adapted to either an external or an internal tag. If you activate the "External Tag" check box, you can undertake a special format adaptation if necessary. To adapt the format of an existing data type, use the button and select the new data type from the list box. You cannot adapt the format of an "Internal Tag." The beginning of this area contains the name of the data structure. The default name is "NewStructure." You can also change this name by selecting the "NewStructure" box and opening the pop-up menu. Select the "Rename" menu item from the pop-up menu and edit the name of the structure. If you want to add a new data type to the data structure, use the "New" button. You can add a new data type to the existing data structure in the two following ways: Select the name of the data structure and use the "New" button to connect the "SHORT NewTag" data type as a default. or Within the existing data structure, select the data type of which you want to create an additional entry and use the "New" button to connect the data type of the selected entry. If you use this means to create a new data type, beware of the following: Not only the data type of the selected entry is transferred, but also the "external/internal tag" setting. To delete an entry in this data structure, select the entry and use the "Delete" button. WinCC Manual Siemens Hardware

122 Control Center PLC: To change the data type, use the following steps: 1. Select the structure element you want to change. 2. Open the pop-up menu and select the new data type. The following data types are listed in the pop-up menu as a default: BIT CHAR BYTE SHORT WORD LONG DWORD FLOAT DOUBLE TEXT8 TEXT16 TEXTREF (only for internal tags) If you activated "External Tag" within the OS area for a structure element, you can use the "Offset" input box to enter the required offset value for the database. The "Length" of the selected data type is also displayed in this area of the window. You can only edit this value if you selected the "TEXT8 " or "TEXT16 " data type. Linear Scaling Linear scaling maps the value range of the process tag to an internal value range. The input fields " Process Value Range From/To and "Value Range of Tag From/To set the value ranges. The linear scaling check-box is only enabled for external tags WinCC Manual

123 08.97 Control Center Using the BIT Data Type: BIT tags always have a structure of 16-bit words. Therefore, bit positions 0 to 15 are the only positions possible. To use every single BIT of a 16-bit word, proceed as follows: 1. Select the last entry in the structure list and use the "New" button. 2. Select the new structure element and click the right mouse button to open the pop-up menu. Select the BIT data type. 3. Select the structure element again and click the right mouse button to open the pop-up menu. Select the "Rename" menu item. 4. Enter a logical name (for example, "Tag_Bit_00") for the structure element. The numeric entry "00" is very sensible for automatic numbering. Note the offset value because you must enter that value later in the structure elements "Tag_Bit_01" to "Tag_Bit_15." 5. Now use the "New" button 15 times to load the "Tag_Bit_01" to "Tag_Bit_15" structure elements. The correct offset value (from "Tag_Bit_00") as well as the required bit numbers are entered automatically. Addressing the Database of a Configured Structure Tag: If you create a new tag of the "Structure" type within a connection, you can use this tag to set the address of the database. 1. In the Control Center Project Navigation Window, double click on "Tag Management." 2. Double click on the required communication driver. 3. Double click on the required channel unit. 4. Select the necessary connection in the Project Navigation Window to view a list of all of the configured tags in the data window. 5. In the Data Window, select the structure tag with the "Structure" type. 6. Open the pop-up menu and select the "Addressing" menu item. 7. The "Address Properties" dialog window opens in which you can set the address of the database. WinCC Manual Siemens Hardware

124 Control Center Deleting a Configured Structure Tag: If you want to delete a configured structure tag, proceed as follows: 1. In the Control Center Project Navigation Window, double click on "Data Types." 2. Double click on "Structure Types." 3. Select the required configured structure which contains the tag you want to delete. 4. In the Data Window, select the structure tag. 5. Open the pop-up menu and select the "Delete" menu item. 6. The "Delete an Object" dialog window opens. Click the "Yes" button in this window to delete the configured tag in the configured connection. Changing the Name of a Configured Structure Tag: If you want to change the name of a configured structure tag, proceed as follows: 1. In the Control Center Project Navigation Window, double click on "Data Types." 2. Double click on "Structure Types." 3. Select the required configured structure that contains the tag whose name you want to change. 4. In the Data Window, select the structure tag. 5. Open the pop-up menu and select the "Properties" menu item. 6. The "Tag Properties" dialog window opens in which you can enter the new name in the "Name" box. The new name of the tag is also updated in the configured connection. Note: If you want to change the name within a configured connection, the "Rename Object" message window opens. This window notifies you that you CANNOT change the name of the tag at this location WinCC Manual

125 08.97 Control Center 10.9 "Raw Data Tags" Are a Special Form of Tags What Are Raw Data Tags? In addition to process tags, the data manager manages so-called raw data tags. From a general point of view, a raw data tag corresponds to a data message frame on the transport level. A raw data tag is not interpreted by the data manager. In order to achieve a certain preselection depending on the additional processing of raw data tags, a raw data tag has a specific type. Note: A tag of this type cannot be displayed in the "Graphics Designer." Raw data tags are only used in the following applications in the WinCC system: "Alarm Logging," "Tag Logging," and "Global Scripts." For example, the communication driver "SIMATIC S7 Protocol Suite" : The "SIMATIC S7 Protocol Suite" channel DLL differentiates among the following raw data types: RDT_EVENT Event processing RDT_ARCHIV Archive data connection RDT_BSEND Sending/receiving a data block RDT_S7PDU Transparent communication A message system usually sends a message for an "RDT_EVENT" raw data type. Process data acquisition accesses tags of the "RDT_ARCHIV" and "RDT_BSEND" types. The "RDT_S7PDU" raw data type is planned for independent use. This way, S7 PDUs that cannot be edited with the channel DLL or the S7 PMC DLL (for example, Object Management System (OMS) and Test and Startup (TIS) functions), can be edited with an (external) WinCC application. The channel DLL selects received S7 Protocol Data Units (PDUs) by means of the PDU header and transmits the corresponding PDUs to the corresponding raw data tags. The WinCC application transmits the raw data tag to a conversion DLL independent of the channel type and raw data type. In an S7 channel, the "RDT_EVENT" and "RDT_ARCHIV" raw data types are transmitted to the S7 Process Monitoring Control (PMC) DLL. Terminology: PDU Protocol Data Unit PMC Process Monitoring Control OMS Object Management System TIS Test and Startup WinCC Manual Siemens Hardware

126 Control Center Addressing a Process Tag General Information about the Address of a Process Tag: Note: Process tags are also called external tags in the following discussion. Each external tag has a channel-specific address description of the source of the process value. The type of address description depends on the type of the remote PLC of the channel unit. External tags are linked to a logical connection. In order to mirror the address information of the different PLC systems, external tags consist of a general section which contains information like name, type, and limit values, and a connection-specific section, whose interpretation is the responsibility of the logical connection. How Can One Address a Process Tag? There are two ways to provide the necessary address information to a process tag: Use the pop-up menu of a selected tag. Use the properties of a selected tag Addressing by Means of the Pop-Up Menu How to Address a Process Tag: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the desired communication driver to view a list of all of the available channel units. 3. Double click on the desired channel unit to view a list of all of the available logical connections WinCC Manual

127 08.97 Control Center 4. If the tag you want to edit is an independent tag or is located in a tag group, you must proceed as follows: If the tag you want to edit is an independent tag: Click on the desired logical connection. If the tag you want to edit is in a tag group: a. Double click on the desired logical connection in the project navigation window to view a list of all available tag groups and independent tags. b. Click on the desired tag group. 5. In the data window, select the desired tag and click the right mouse button. 6. In the pop-up menu that then appears, select the " Addressing..." menu item. 7. This selection opens the "Address Properties" dialog box in which you can address the process tag Addressing by Means of the Properties of a Tag How to Address a Process Tag: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the desired communication driver to view a list of all of the available channel units. 3. Double click on the desired channel unit to view a list of all of the available logical connections. 4. If the tag you want to edit is an independent tag or is located in a tag group, you must proceed as follows: If the tag you want to edit is an independent tag: Click on the desired logical connection. If the tag you want to edit is in a tag group: a. Double click on the desired logical connection in the project navigation window to view a list of all available tag groups and independent tags. b. Click on the desired tag group. WinCC Manual Siemens Hardware

128 Control Center In the data window, select the desired tag and click the right mouse button. 6. In the pop-up menu that then appears, select the " Properties" menu item. 7. This selection opens the "Tag Properties" dialog box. 8. In the "Tag Properties" dialog box, click the "Select" button. 9. This action opens the "Address Properties" dialog box in which you can address the process tags WinCC Manual

129 08.97 Control Center "Address Properties" Dialog Significance of the "Address Properties" Dialog: Use this dialog to set the address of the process tags within the connected remote PLC. Structure of the "Address Properties" Dialog Window: The dialog window contains one tag ("Address") whose contents depend on the current communication driver. You can find additional information about this dialog window in the Channel DLL, Communication Driver manual "Address" Tab for "SIMATIC S5 Ethernet TF" Structure of the "Address Properties" dialog box for the "SIMATIC S5 Ethernet TF" communication drivers: The dialog box contains 1 tab ("Address") with the following contents: Box Address Description CPU Data Area Addressing Explanation Enter the number of the CPU in the remote PLC system from which the data are read. You can use a number between 1 and 4. This box is only available for multi-processor systems. In all other cases, this box is inactive and looks gray. This box is dependent on the selected data type and represents a set data area in the RAM of the control unit (PLC). You can choose from the following data areas: DB (data block) DX (extended data block) Bit memory Input Output This box is dependent on the selected data type and the selected data area. You can choose from the following addressing types: Bit Byte Left Byte Right Byte Word Double Word WinCC Manual Siemens Hardware

130 Control Center This area (see the "Address Properties" figure below) is used only by "Raw Data Type" tags. Additional boxes are located in this area. You can specify the block length of the raw data as well as the type of raw data. In this box, you can enter the start address of the tags. This number value corresponds to the offset to the data base within the RAM. To the left of this box, the data area and possibly the type of addressing are identified with one or two letters. In this example, "DL" is made up of the "DB" (data block) data range and the "Left Byte" addressing. The first letters from the "Data Area" and "Addressing" boxes are used as the identifiers. The "Bit" addressing is an exception. If this type of addressing is set, only one letter is displayed, the one from the "Data Area" box. In this example, "D" is taken from the "DB" (data block) data area. Pay attention to the following: you must enter the word address in the "D" box. The "Bit" box is only visible when the "Bit" addressing is selected. You can enter a number between 0 and 15 in this box. The number range depends on the selected data range (for example 0 to 7 or 0 to 15) WinCC Manual

131 08.97 Control Center You can enter the data block number in this box. The "DB No." box is only visible when you are dealing with a data block (data area DB or DX). For an S5 communication driver, you can choose from a number range from 0 to 255. For an S7 communication driver, you can choose from a number range of 0 to This picture shows you the standard structure of the "Address Properties" dialog box. This picture shows you the additional boxes in the lower area of the "Address Properties" dialog box for the "SIMATIC S7 Protocol Suite" communication driver. WinCC Manual Siemens Hardware

132 Control Center This picture shows you the additional boxes in the lower area of the "Address Properties" dialog box for the "SIMATIC S5 Ethernet TF" communication driver. Structure of the Lower Window Area: Box Explanation Raw Data If you activate this box, the "Raw Data Type" area and the "Length" box are enabled. Length Raw Data Type Send/Receive Block Event Archive Data Link You can enter the maximum expected block length in this box. The length unit for this box is byte. This option button is displayed for the S5 and S7 communication drivers. With an S5, this box is active as a default. The process data acquisition uses this raw data type as a rule. This option button is only displayed for an S7 communication driver. If you activate this button, all of the boxes in the "Address Description" area become inactive and are displayed in gray. A message system uses this raw data type as a rule. This option button is only displayed for an S7 communication driver. If you activate this button, all of the boxes in the "Address Description" area become inactive and are displayed in gray. The process data acquisition uses this raw data type as a rule WinCC Manual

133 08.97 Control Center "Select Tag" Dialog The tags configured in the Control Center can be accessed by the editors via the "Select Tag dialog. Structure of the "Select Tag" Dialog: Field Project Tag Filter Description Displays the path and name of the current project. In this field, set a search condition for the tag name via the wild characters "? and "*. If you exit the field via the "TAB key, only tags conforming to the search criteria will be displayed. This button allows you to create a new tag. This button sets the display type "Small Icons for the window. This button sets the display type "Detailed View for the window. WinCC Manual Siemens Hardware

134 Control Center WinCC Manual

135 08.97 Control Center 11 Tag Group 11.1 General Information About a Tag Group What Is a Logical Tag Group? A logical connection describes the interface between the automation system and the data manager. Each tag group is assigned to a channel unit. A channel unit can contain multiple tag groups. Note: The name of the tag group must be unique in the entire project. If this requirement is not fulfilled, a window appears with the name of the tag group that was already assigned in the project. There are three ways to create a tag group: Note: The third item also deals with deleting tag groups. Create a new connection and assign a tag group to it. Assign a tag group to an existing connection. Cut, copy, or delete one or more tag groups Creating a Tag Group in a New Connection How to Create a Tag Group When You Create a New Connection: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the desired communication driver to view a list of all available channel units. 3. Select the desired channel unit and click the right mouse button. 4. In the pop-up menu that then appears, select the " New Connection..." menu item. 5. This selection opens the "Connection Properties" dialog box in which you can create new logical connections. 6. In the "General Information" tab, enter the name of the logical connection in the "Name" box. WinCC Manual 11-1 Siemens Hardware

136 Control Center Switch to the "Groups" tab. 8. Click the "New" button. This selection opens the "Tag Group Properties" dialog box in which you can create the new tag group Creating a Tag Group in an Existing Connection How to Create a Tag Group in an Existing Connection: 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers. 2. Double click on the desired communication driver to view a list of all available channel units. 3. Double click on the desired channel unit to view a list of all available logical connections. 4. Select the desired logical connection and click the right mouse button. 5. In the pop-up menu that then appears, select the " New Group..." menu item. 6. This selection opens the "Tag Group Properties" dialog box in which you can create new tag groups WinCC Manual

137 08.97 Control Center Cutting, Copying, or Deleting Tag Groups How to Cut, Copy, or Delete One or More Tag Groups in an Existing Logical Connection: Note: The task sequence for cutting, copying, or deleting is the same for all tag groups. 1. In the project navigation window, double click on the "Tag Management" project component. This action provides a list of all of the installed communication drivers and internal tags. 2. Double click on the desired communication driver to view a list of all available channel units. 3. Double click on the desired channel unit to view a list of all available logical connections. 4. Select the desired logical connection in the project navigation window. The data window then displays all the configured tags and tag groups. 5. Highlight the tag groups and c lick the right mouse button. Note: You can highlight tag groups using either of the two procedures described below. How to Select Multiple Tag Groups in a List: 1. Highlight the first tag group. 2. Click the left mouse button. 3. Press the <Ctrl> key and hold it down. 4. Then select the next tag groups you want to highlight and click on each one with the left mouse button. 5. When all of the tag groups you want to select are highlighted, release the <Ctrl> key. How to Select a Block of Contiguous Tag Groups in a List: 1. Highlight the first tag group. 2. Click the left mouse button. 3. Press the <Shift> key and hold it down. 4. Then select the last tag group in the list you want to highlight and click the left mouse button. Release the <Shift> key. 5. All of the tag groups between the selected tag groups are highlighted. 6. In the pop-up menu that then appears, select the "Cut," "Copy," or "Delete" menu item. WinCC Manual 11-3 Siemens Hardware

138 Control Center If you want to paste one more cut or copied tag groups: 6. Select the target area to which you want to copy the selected tag groups. 7. Click the right mouse button in the data window. 8. Select "Paste" in the pop-up menu that appears. 9. This action copies all of the selected tag groups to the target area. You must be aware of the following in this copy procedure: Each of the copied tag groups and their tags receive a sequential number as is shown in the following examples: The "BinVarGroupS5TF" tag group is renamed "BinVarGroupS5TF_1" after it is copied. The "BinVarGroupS5TF_1" tag group is renamed "BinVarGroupS5TF_2" after it is copied. The "BinVarS5TF" tag that may be located in a tag group is renamed "BinVarS5TF_1" after it is copied. The "BinVarS5TF_1" tag that may be located in a tag group is renamed "BinVarS5TF_2" after it is copied. The "BinVarS5TF_DB70" tag that may be located in a tag group is renamed "BinVarS5TF_DB71" after it is copied. If you want to delete one or more tags: 6. In the following dialog window "Delete nnn Object(s)," click the "Yes" button. The selected tag groups with the tags contained in them are deleted (nnn is the number of selected objects) WinCC Manual

139 08.97 Control Center 11.2 "Tag Group Properties" Dialog Structure of the "Tag Group Properties" Dialog Box: Note: The number of tabs depends on the action to be carried out. If you are creating a new group, only the "General Information" tab appears. If you are editing the properties of an existing tag group, a dialog box appears with the "General Information" and "Tag" tabs. The dialog box contains one or two tabs with the following contents: Tab General Information Tag Contents You can create a new tag group or edit the name of an existing tag group in the " General Information" tab. You can delete a tag or create a new tag in the "Tag" tab. This example shows you the Title Bar of the dialog box when you are creating a new tag group (standard group name is " NewGroup"). This example shows you the Title Bar of the dialog box when you are editing an existing tag group (current group name: " Machine"). WinCC Manual 11-5 Siemens Hardware

140 Control Center "General Information" Tab Structure of the "General Information" Tab: The individual boxes have the following meaning: Box Name Name Number of Tags Explanation Unique name of the tag group. If you do not assign a unique name, an error message appears. Number of tags assigned to the tag group. You cannot edit this box. This example shows the dialog box when you are creating a new tag group (standard group name "New Group"). Use the "OK" button to apply all of the settings you made, or use "Cancel" to reject those settings. Use the "Help" button to access the help system. Message Box for a Name Match: If the name you selected for the tag group already exists, the following dialog box appears. In this example, the WinCC system has determined that the name " Milch" was already assigned to another tag group. The individual buttons mean the following: Button Yes No Explanation Click this button to have the WinCC system create a unique name. Click this button to exit the dialog box without creating a new tag group WinCC Manual

141 08.97 Control Center "Tag" Tab Structure of the "Tag" Tab: The individual areas have the following meaning: Box/Button Tags "New" Button "Delete" Button "Properties" Button Explanation All of the current tags in the tag group are listed in this box. Use this button to add new tags to the current tag group. Selecting this button opens the "Tag Properties" dialog box. Use this button to delete the selected tag. Use this button to edit or view the properties of the current tag. Selecting this button opens the "Tag Properties" dialog box. This examples shows you all of the tags in the current tag group " Maschine" WinCC Manual 11-7 Siemens Hardware

142 Control Center WinCC Manual

143 08.97 Control Center 12 The Control Center Editors What are Editors and Where Are They Located? Use the editors to edit and control a complete project. The following list contains all of the standard editors of the WinCC system. In the Control Center, the editors are located in the "Editor" project component which is located in the project navigation window. WinCC is Delivered With the Following Editors: Editor Alarm Logging User Administrator Text Library Report Designer Global Scripts Tag Logging Graphics Designer Explanation Accepts messages from processes in order to prepare, display, acknowledge, and archive those messages. Controls access authorizations for groups and users. Contains language-dependent text that you create. Provides an integrated reporting system that you can use to report user data, current and archived process values, current and archived messages, and your own system documentation. Enables you to make a project dynamic according to your specific requirements. This editor allows you to create C functions and actions that can be used throughout the project or across multiple projects depending on their type. Processes measurement values and stores them long-term. Provides graphic displays and connections to the process. WinCC Manual 12-1 Siemens Hardware

144 Control Center Editor "Alarm Logging" Alarm Logging Offers the Following Features: Comprehensive information about error and operating states Early recognition of critical situations Avoidance and reduction of down time Increase in product quality Its own on-line help How to Open Alarm Logging: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Alarm Logging" editor. 3. In the pop-up menu that appears, select the "Open" menu item. 4. This selection starts "Alarm Logging" and you can initialize the functions to accept messages from processes and prepare, display, acknowledge, and archive those messages Editor "User Administrator" The User Administrator Offers the Following Features: Assignment and management of access authorization Protection of data from unauthorized access Its own on-line help. How to Open the User Administrator 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "User Administrator" editor. 3. In the pop-up menu that appears, select the "Open" menu item. 4. This selection starts the "User Administrator" and you can assign the user and group authorizations. How To... Edit the properties of the "User Administrator." 12-2 WinCC Manual

145 08.97 Control Center Editing the Properties of the User Administrator "Properties" Dialog You must use the following work steps to edit the properties of the User Administrator. How to Edit the Properties of the "User Administrator": 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "User Administrator" editor. 3. In the pop-up menu that appears, select the "Properties" menu item. 4. This selection opens the "Properties" dialog box. Use this dialog box to view the properties of the "User Administrator." Significance of the "Properties" Dialog Box: Use this dialog box to set up the connection port for a chip card reader. Note: The "Chip Card Reader" tab is only available if you activate the "Chip Card" check box under the "Options" point in the "Subcomponents" dialog box during installation. Structure of the "Properties" Dialog Box: The dialog box contains two tabs. The individual tabs have the following meaning: Tab Version Chip Card Reader Explanation This tab contains only general statements regarding the current program version as well as a copyright notice. You can set the connection port of the card reader in this tab. As a default, a serial interface is supported. Use the button to select the necessary interface (pay attention to the remarks box). Use the "Apply" button to accept the selected connection port into your current project. WinCC Manual 12-3 Siemens Hardware

146 Control Center Editor "Text Library" The Text Library Offers the Following Features: Assignment of user text to individual messages within the "Alarm Logging" editor The ability to prepare user texts for different languages This picture shows you the languages installed as defaults (German and English) in the Text Library. Use the "Properties of a Computer" dialog to determine which of the configured languages should be used in RUNTIME mode. Its own on-line help How to Open the Text Library: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Text Library" editor. 3. In the pop-up menu that appears, select the "Open" menu item. 4. This selection opens the "Text Library" and you can view or edit the configured user text WinCC Manual

147 08.97 Control Center 12.4 Editor "Report Designer" General Information about the Report Designer: WinCC offers an integrated report system with which you can create reports about user data, current and archived process values, current and archived messages, and your own system documentation. The Report Designer Offers the Following Features: Convenient and simple user interface with tool and graphic palettes Support of different reporting methods Support of the output media supported by Windows Page-by-page display of reports that are already archived Support of the OLE 2.0 interface A 32-bit application that can run under Windows 95 and Windows NT Standard system layouts and print jobs Its own on-line help for page layout and for line layout Note: In the data window in the Control Center, the system layouts and system print jobs of the Report Designer are identified with the "@" symbol. The system layouts and system print jobs can be edited. There are three sub-items in the project navigation window for the Report Designer: Page Layout Line Layout Print Job Behavior of the Report Designer in RUNTIME Mode: Use the "Properties" dialog to set the behavior of the Report Designer when errors occur in RUNTIME mode. WinCC Manual 12-5 Siemens Hardware

148 Control Center "Properties" Dialog The Report Designer allows you to use the "Properties" dialog to determine the behavior of the editor in case of errors during RUNTIME mode. The dialog box consists of a tab ("Behavior in RUNTIME") with two selection boxes. Note: As a default, both of these selection boxes are activated within the dialog. The individual selection boxes have the following meaning: Selection Box Display Status Dialog Display "Print To " Dialog Explanation If you deactivate this selection box, the second selection box ("Display Print To Dialog") is also deactivated. If you activate this selection box, the "PrintIt" status dialog is displayed. This selection box is only available if the first selection box ("Display Status Dialog") was activated. How to Set the Behavior of the Report Designer during an Error in RUNTIME Mode: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Report Designer" editor. 3. In the pop-up menu that appears, select the "Properties" menu item. 4. The "Properties" dialog box opens and you can make the desired settings WinCC Manual

149 08.97 Control Center Layouts in the Report Designer The Report Designer enables you to release a report when certain events occur. You can create the layout of this report yourself. You can assign the layout you create to a print job. The Following Report Layouts Are Available: Page Layout Line Layout This picture shows you the structure of the "Report Designer" in the project navigation window. The following topics describe the general work sequence for editing a report layout. How To: Create a new layout Open an existing layout Rename an existing layout Delete an existing layout View the properties of a layout WinCC Manual 12-7 Siemens Hardware

150 Control Center Creating a New Layout in the Report Designer The following steps are necessary for creating a new page layout or line layout. How to Create a New Layout: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view the installed "Page Layout," "Line Layout," and "Print Job" sub-items. 3. Click the right mouse button on one of the "Layout" sub-items. 4. In the pop-up menu that appears, select the "New Layout" or "New Line Layout" menu item. 5. In the data window, the file "NewRPLnn.RPL" is loaded under the "Page Layout" project component. or The file "NewRP1nn.RP1" is loaded under the "Line Layout" project component. The files are sequentially numbered "nn" (number ra nge between 0 and 99). 6. You can then open the new layout by double clicking on it. This action starts the Report Designer with the selected layout and you can edit the layout. Note: You should rename the newly created, "NewRPLnn.RPL" or "NewRP1nn.RP1" with a recognizable name (for example, "Alarm1.RPL" or "Alarm2.RP1") WinCC Manual

151 08.97 Control Center Opening an Existing Layout in the Report Designer The following steps are necessary for opening an existing page layout or line layout. How to Open an Existing Layout: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view the installed "Page Layout," "Line Layout," and "Print Job" sub-items. 3. Click on the "Page Layout" or "Line Layout" sub-item. The data window then displays all of the available layouts. 4. In the data window, select the desired layout and click the right mouse button. 5. In the pop-up menu that appears, select the "Open Layout" or "Open Line Layout" menu item. 6. This selection starts the "Report Designer" with the selected layout. You can edit the layout. WinCC Manual 12-9 Siemens Hardware

152 Control Center Renaming an Existing Layout in the Report Designer The following steps are necessary for renaming an existing page layout or line layout. How To Rename an Existing Layout: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Page Layout," "Line Layout," and "Print Job" sub-items. 3. Click on the "Page Layout" or "Line Layout" sub-item. The data window then displays all of the available layouts. 4. In the data window, select the desired layout and click the right mouse button. 5. In the pop-up menu that appears, select the "Rename Layout" or "Rename Line Layout" menu item. 6. This selection opens the "New Name:" dialog. 7. Change the name of the selected layout and use the "OK" button. The new name is then applied to the selected layout Deleting an Existing Layout in the Report Designer The following steps are necessary for deleting an existing page layout or line layout. How to Delete an Existing Layout: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Page Layout," "Line Layout," and "Print Job" sub-items. 3. Click on the "Page Layout" or "Line Layout" sub-item. The data window then displays all of the available layouts. 4. In the data window, select the desired layout and click the right mouse button. 5. In the pop-up menu that appears, select the "Delete Layout" or "Delete Line Layout" menu item. 6. The selected layout is then deleted. Note: When you select the "Delete Layout" or "Delete Line Layout" menu item, the selected layout is deleted immediately WinCC Manual

153 08.97 Control Center Viewing the Properties of an Existing Layout in the Report Designer The following steps are necessary for viewing the properties of an existing page layout or line layout. How to View the Properties of a Layout: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click on the "Layout" sub-item. The data window then displays all of the available layouts. 4. In the data window, select the desired layout and click the right mouse button. 5. In the pop-up menu that appears, select the "Properties" menu item. 6. This selection opens a dialog box with the data about when the layout was created and when the last change was made. You can also see a page preview of the selected layout. Use the "OK" button to close the dialog box. This example shows you the "Page Layout" properties dialog box. The dialog box for a "Line Layout" has an identical structure. WinCC Manual Siemens Hardware

154 Control Center Print Jobs in the Report Designer The Report Designer allows you to print out print jobs with a specific layout. You can create the layout for the report yourself. The following topics describe the work sequence for editing a print job. Note: When you have created a print job, the "Parameter" column in the data window identifies the output location of the report with the abbreviations (F), (F,P), or (P). (F) means output to a file and (P) means output to a printer. If (F,P) is displayed, the output goes to a file and to a printer. This example shows you the identifiers for several print jobs in the data window. How To: Create a new print job Delete an existing print job Activate the print preview for a print job Print out an existing print job Edit the properties of a print job Rename an existing print job Creating a New Print Job in the Report Designer The following steps are necessary for creating a new print job. How to Create a New Print Job: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click the right mouse button on the "Print Job" sub-item. 4. In the pop-up menu that appears, select the "New Print Job" menu item. 5. This selection opens the "Properties" dialog box where you can create a new print job WinCC Manual

155 08.97 Control Center Deleting an Existing Print Job in the Report Designer The following steps are necessary for deleting a print job. How to Delete an Existing Print Job: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click on the "Print Job" sub-item to view a list in the data window of all of the available print jobs. 4. In the data window, select the desired print job and click the right mouse button. 5. In the pop-up menu that appears, select the "Delete Print Job" menu item. 6. This selection opens a dialog box. This box contains the name of the selected print job and asks if you want to delete it. Use the "Yes" button to delete the selected print job. WinCC Manual Siemens Hardware

156 Control Center Activating a Print Preview in the Report Designer The following steps are necessary to activate a print preview of a print job. How to Activate a Print Preview of a Print Job: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click on the "Print Job" sub-item to view a list in the data window of all of the available print jobs. 4. In the data window, select the desired print job and click the right mouse button. 5. In the pop-up menu that appears, select the "Preview Print Job" menu item. 6. This selection opens a dialog box. The name of the selected layout is displayed in the title bar of the dialog box. A preview of the print job is also displayed in this box. Use the "Print" button to print the selected print job immediately. Use the "Close" button to end the print preview. Use the other buttons to zoom the preview or select another page. This example shows you the print data preview WinCC Manual

157 08.97 Control Center Printing an Existing Print Job in the Report Designer The following steps are necessary for printing a print job. How to Print a Print Job: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click on the "Print Job" sub-item to view a list in the data window of all of the available print jobs. 4. In the data window, select the desired print job and click the right mouse button. 5. In the pop-up menu that appears, select the "Print the Print Job" menu item. 6. The selected print job is printed. Note: Use the "PrintIt" dialog box to cancel the current print job or view the current status of the print job. If you want to interrupt the current print job, use the "Cancel" button. "Print It" dialog box for a print out to a printer: This example shows you the "PrintIt" dialog box in which you can view the status of the print job. WinCC Manual Siemens Hardware

158 Control Center Editing the Properties of an Existing Print Job in the Report Designer The following steps are necessary for editing the properties of an existing print job. How to Edit the Properties of a Print Job: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click on the "Print Job" sub-item to view a list in the data window of all of the available print jobs. 4. In the data window, select the desired print job and click the right mouse button. 5. In the pop-up menu that appears, select the "Properties" menu item. 6. This selection opens the "Properties" dialog box. Use this dialog box to edit all of the settings that affect the selected print job WinCC Manual

159 08.97 Control Center Renaming an Existing Print Job in the Report Designer The following steps are necessary for renaming an existing print job. How to Rename an Existing Print Job: 1. In the project navigation window double click on the "Editor" project component to view a list of all of the installed editors. 2. Double click on the "Report Designer" project component to view all of the installed "Layout" and "Print Job" sub-items. 3. Click on the "Print Job" sub-item to view a list in the data window of all of the available print jobs. 4. In the data window, select the desired print job and click the right mouse button. 5. In the pop-up menu that appears, select the "Properties" menu item. 6. This selection opens the "Properties" dialog box. 7. Select the "Print Job" tab. 8. Edit the "Name" box in this tab "Properties" Dialog for Print Jobs General Information about This Dialog Box: In the Control Center, each configured print job has a "Properties" dialog box. You can use this dialog box to assign special settings to each print job. The box contains the following three tabs: Tab Print Job Selection Printer Specification Contents You can enter general data about the print job in this tab. You can enter data about the page range and the time range of the print data in this tab. Use this tab to set the output unit for the print job. You can also send the print job to a file. WinCC Manual Siemens Hardware

160 Control Center "Print Job" Tab Structure of the "Print Job" Tab: The individual boxes have the following meaning: Box Name Name Project Layout Line Layout for Line Printer Explanation Enter the name of the print job here. The name must be unique within a project and must conform to Windows conventions. The project name with a complete path for the print job is displayed here. You cannot edit this box. Assign a report layout to the print job here. The layout must be available already. If you have not entered a layout in this area and if you attempt to open one of the other tabs, the "PRTRTAPI" dialog box appears. This dialog box notifies you that you are working with a system print job to which a layout must be assigned. Use this selection button to send all of the reports as line layouts to a line printer. You must input a previously configured line layout (<Filename>.RP1) in the "Layout" box. All of the values in the "Start Parameter" area are displayed in gray and are therefore not available. In the tab, the icon changes from to. Note: This check box is enabled only for the system print job "@Report Alarm Logging RT Message sequence." WinCC Manual

161 08.97 Control Center Last Printout On Next Printout On Start Parameter Start Time Cycle Event The date of the last printout of this print job is displayed here. You cannot edit this box. It is only used to describe the print job status. The date of the next printout of this print job is displayed here. You cannot edit this box. It is only used to describe the print job status. Set the start time and date of the print job. You can set the cyclic startup of the print job here. You must first have set the start time and date of the print job. The following cycle ranges are available for selection: <NONE> Hourly Daily Weekly Monthly Set the trigger of the print job dependent on an event. WinCC Manual Siemens Hardware

162 Control Center Note: You see this icon in the Control Center data window when you activate "Start Time." You see this icon in the Control Center data window when you activate "Start Time" and "Cycle." This example shows you the "Print Job" tab WinCC Manual

163 08.97 Control Center "Selection" Tab Structure of the "Selection" Tab: The individual boxes have the following meaning: Box Name Page Range All Pages from nnn to nnn Time Range Relative (back from start time) Number Explanation All of the pages of the print job are printed. Set the print job to print out individual pages or a page range. You can select between a relative or an absolute time range. The active time range is identified by the option button. The passive time range is displayed in gray. Use this option button to define a relative time range going back from the start time. The following possibilities are available for a relative time range: All Years Months Weeks Minutes Days Hours Here you can set the size of the time range. Values between 1 and 100 are possible. WinCC Manual Siemens Hardware

164 Control Center Absolute From nnn To nnn Click on this option button to define an absolute time range going back from the print start time. Set the time range and date for the print job. This example shows you the "Selection" tab WinCC Manual

165 08.97 Control Center "Printer Specification" Tab Structure of the "Printer Specification" Tab: The individual boxes have the following meaning: Box Name Print Output On... Printer Printer Priorities File (*.emf) Explanation When you click on this check box to activate it, the "Printer Priorities" boxes are enabled and you can set the printer you want to use. 1.) Enter the first printer here. The system always attempts to access this printer. If this printer is not ready, the second printer provided is activated. Note: If you activated the "Line Layout for Line Printer" selection box in the "Print Job" tab, you can enter the desired parallel interface in this box (for example, LPT1). Boxes 2 and 3 within the printer priorities are deactivated. 2.) Enter the second printer here. The system always attempts to access this printer if the first printer is not ready. If this printer is not ready either, the third printer provided is activated. 3.) Enter the third printer here. The system always attempts to access this printer if the first and second printers are not ready. If you click on this check box to activate it, the print jobs which occur are sent to a file. In the "Archive" box, enter the name of the path on which the file is to be loaded. The name of the path is constructed as follows: from the project path (like C:\VFSWinCC\PRT\") as well as <Archive> + <YYYYMMDDHHMM> (JJJJ = Year, MM = Month, DD = Day, HH = Hour, MM = Minute). WinCC Manual Siemens Hardware

166 Control Center Note: If you load, for example, the "Archive" box with "Pdata,, WinCC will load the following path structure within the project directory for the print job. You would find one or more files named "Page<nnn>.emf" (<nnn> being sequential numbers) in this folder. If you do not make any entries in the "Archive" box, WinCC loads the path <YYYYMMDDHHMM>. You cannot enter a back slash (\) in the "Archive" box to set additional subpaths. Note: If the printer malfunctions during a cyclic report, WinCC might halt. Solution: Deactivate the setting "Store Print Jobs in Clipboard in Windows (e.g. in "Win95\Control Panel\ Printer\Details\Connection Settings ) WinCC Manual

167 08.97 Control Center 12.5 Editor "Global Scripts" General Information about Global Scripts: Global Scripts is the general term for C functions and actions that can be used throughout a project or even in other projects. The Global Scripts Editor Offers the Following: The capability to create C functions and actions The capability to implement these C functions and actions through the entire project or even in other projects Its own on-line help How to Open Global Scripts: Note: If you want to view or edit specific "Global Scripts," you can call them up directly from the Control Center. In the project navigation window, you select the folder with the desired script and open the pop-up menu. In the pop-up menu, select the "Open " menu item. The "Global Scripts" module is then loaded with the selected script. 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on "Global Scripts." 3. In the pop-up menu that appears, select the "Open " menu item. 4. "Global Scripts" starts and you can view or edit the configured scripts. WinCC Manual Siemens Hardware

168 Control Center Editor "Tag Logging" Tag Logging Offers the Following Features: Optimized, efficient use of the system Transparency of the operating procedures Increase in productivity Increase in product quality Optimized delay cycles Its own on-line help How to Open Tag Logging: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Tag Logging" editor. 3. In the pop-up menu that appears, select the "Open" menu item. 4. This selection starts "Tag Logging" and you can initialize the data values and the properties of the connection Editor "Graphics Designer" The Graphics Designer Offers the Following Features: Easy-to-use, simple interface that maintains the Windows operating philosophy Streamlined configuration with an integrated icon library Open interfaces for importing graphics and supporting the OLE 2.0 interface Configurable dynamic behavior of picture objects with support from an assistant (Dynamic Wizard) Links to additional functions by means of powerful script configuration Links to graphic objects that you can create yourself Its own on-line help The following describes the sequence for editing a picture or the available graphic objects WinCC Manual

169 08.97 Control Center How To: Load a new picture Open an existing picture View the properties of an existing picture Edit the properties of the "Graphics Run Time" Link new objects to the "Graphics Designer" Convert pictures or libraries Loading a New Picture in the Graphics Designer The following steps are necessary for loading a new picture. How to Load a New Picture: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Graphics Designer" editor. 3. In the pop-up menu that appears, select the "New Picture" menu item. 4. This selection starts the "Graphics Designer" and you can create a new picture Opening an Existing Picture in the Graphics Designer The following steps are necessary for opening an existing picture. How to Open an Existing Picture: 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click on the "Graphics Designer" editor. 3. In the data window, select the desired picture and click the right mouse button. In the pop-up menu that appears, select the "Open Picture" menu item. This selection starts the "Graphics Designer" and you can edit the selected picture. or In the data window, double click on the desired picture. This action starts the "Graphics Designer" and you can edit the selected picture. WinCC Manual Siemens Hardware

170 Control Center Editing the Properties of the Graphics RUNTIME The following steps are necessary for editing the properties of a picture in Graphics RUNTIME. How to Edit the Properties of a picture in "Graphics RUNTIME": 1. In the project navigation window, double click on the "Computer" project component to view a list of all of the configured computers. 2. In the data window, click the right mouse button on the computer whose properties you want to edit. 3. In the pop-up menu that appears, select the "Properties" menu item. 4. This selection opens the "Computer Properties" dialog. In this dialog, select the "Graphics RUNTIME" tab in which you can set the behavior of the selected start picture in RUNTIME mode Viewing the Properties of a Picture The following steps are necessary to view the properties of a picture within the Graphics Designer. This dialog window provides the following information: A preview of the picture in the left half of the window Date and time when the picture was created Date and time when the last change was made Size of the PDL file in bytes Configured picture size in pixels (for example, 80*155) Number of configured objects in the picture WinCC Manual

171 08.97 Control Center How to View the Properties of a Picture in the "Graphics Designer": 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Graphics Designer" editor. 3. In the data window, select the PDL file whose properties you want to view. Click the right mouse button. 4. In the pop-up menu that appears, select the "Properties" menu item. 5. This selection opens the "nnn.pdl" dialog box (nnn stands for the file name). Use this dialog to view the properties of the selected picture. This example shows you the properties of a "WinCC_R1.pdl" picture Linking New Objects in the Graphics Designer The following steps are necessary for linking new objects in the "Graphics Designer." How to Link New Objects in the "Graphics Designer": 1. In the project navigation window, double click on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Graphics Designer" editor. 3. In the pop-up menu that appears, select the "Graphic OLL" menu item. 4. This selection opens the "Object-OLL" dialog box. Use this dialog box to link new objects in the "Graphics Designer." WinCC Manual Siemens Hardware

172 Control Center "Object OLL" DLL Purpose of the Dialog Box: Use this dialog box to add additional objects to the "Graphics Designer." These objects expand the "Graphics Designer" by adding elements for visualizing a process. These additions can be text objects, button objects, or OLE objects. Structure of the "Object OLL" Dialog Box: Note: There is a context-sensitive help in the "Object OLL" dialog box. Use the button to activate this help function. If you have clicked on this button, the cursor changes to an arrow with a question mark attached. Select the area or button about which you want more information. The dialog box is divided into three screen areas. The individual areas and buttons have the following meaning: Area/Button Available GraphicOLLs Explanation All of the OLLs that are not yet linked to the "Graphics Designer" are listed in this area. Selected GraphicOLLs All of the OLLs that are already linked to the "Graphics Designer" are listed in this area. If you select an OLL in this area and click the "Preview" button, all of the objects of the selected OLL are displayed in area WinCC Manual

173 08.97 Control Center Use these buttons to shift individual OLLs from one area to another. "Have Disk" Use these buttons to shift all of the OLLs in one area to another area. Use this button to link additional OLL files. These files can be on a diskette, hard disk, or network. In this dialog, use the "Browse" button to access the "Graphic OLL" dialog box in which you can search for the required OLL files. Use the "OK" button to apply all the settings you made, or use the "Cancel" button to reject those settings. This picture shows you the standard structure of the "Object OLL" dialog box. WinCC Manual Siemens Hardware

174 Control Center Converting Pictures or Libraries You can convert older pictures or libraries to the current format of the Graphics Designer. Use these options to not only convert pictures and libraries, but also compress existing ones. How to Convert Pictures or Libraries: 1. Double click in the project navigation window on the "Editor" project component to view a list of all of the installed editors. 2. Click the right mouse button on the "Graphics Designer" editor. 3. In the pop-up menu that appears, select the required menu item. You can activate one of the following menu items:. "Convert Pictures" Use this command to convert all configured pictures. "Convert Global Library" Use this command to convert the global library. "Convert Project Library" Use this command to convert the project library. Note: In Graphics Designer, use the "View" "Library" menu items to edit your current libraries WinCC Manual

175 08.97 Control Center 13 DDE-Server 13.1 General Information about the DDE-Server General Information about the DDE-Server: The WinCC DDE-server is an independent application for WinCC. It requires WinCC to be in runtime in order to assign the configured tags of a WinCC project to any DDE-clients. The DDE-server is only required for the data exchange through the network. Operating the DDE-Server: The operation of the DDE-server takes place via the "WinCC DDE- Server" dialog window. This dialog window is only visible, if the parameter "/v" has been indicated within the start-up list of the computer. The dialog window will be opened while runtime is activated. Structure of the "WinCC DDE-Server" Dialog Window: The individual elements of the dialog window have the following meaning: Field Name Settings Server ready Lock writing Select Tag "Tag List" Description The DDE-server can be deactivated via this check-box. If the server is deactivated, no new connections can be established to the DDE-server, additionally, no data transfer will take place on the existing connections. The writing of the tags can be locked via this check-box. If WinCC runtime has been activated, the tag selection dialog of the Control Center can be called up via this button. All the configured tags are listed within the " Select Tag" dialog. The DDE-address of the selected tag will be copied into the clipboard in a DDE-link format. This address can then, for example, be inserted directly into Excel as a link. Note: This button is only enabled, if WinCC runtime has been activated. WinCC Manual 13-1 Siemens Hardware

176 Control Center Integrating Tags via DDE This chapter describes how a configured WinCC tag can be directly integrated into Excel. There are two ways to establish a DDE-connection: Local DDE-Connection WinCC runs on a local computer as a single-user system, or on a server computer as a multi-user system. DDE-Connection via a Network It is not required to start WinCC on the local computer to establish a DDE-connection. Both methods require the program "DDEServ.exe" to be added to the WinCC computer start-up list with the parameters "/v /nohold /noconfirm". Note: The parameters "/nohold /noconfirm" have the following meaning: If WinCC is exited, the DDE-server will be deactivated without requiring acknowledgment by the user. The parameter "/v" opens the "WinCC DDE-Server" dialog window. Note the correct entry of these parameters. A blank character (space) must be inserted between the parameters Local DDE-Connection To establish a local DDE-connection, one of the following requirements must be met: WinCC running on a local computer... as a single-user system or as a multi-user system on a server computer. Within WinCC, the following preparatory measures must be performed: Within the computer start-up list, the DDE-server must be incorporated. The DDE-server is located in the WinCC installation path (e.g. "C:\SIEMENS\WINCC\BIN\DDESERV.EXE"). The DDE-server must be started with the parameters " /v /nohold /noconfirm". The"/v" parameter opens the dialog window of the DDE-server. This dialog windows allows you to select a project tag. Within Excel, a WinCC tag can be integrated in the following way: 13-2 WinCC Manual

177 08.97 Control Center Change to the DDE-server. Display the tag list of the current WinCC project by clicking on the "Tag List button. A tag can be selected from this dialog and be copied into the clipboard, as the DDE-reference, by clicking on the "OK" button. Activate the Excel program. Select the cell, in which you want to display the value of the WinCC tag. Enter an equal sign = in the Excel formula bar. Copy the DDE-reference into the formula bar via the < Ctrl > + < V > key combination. Hit the return key to accept the value of the WinCC tag into the Excel cell. This example displays an Excel table. The value of the WinCC tag DDEVar1, which is contained in the Test2.mcp project, will be displayed in cell A1. WinCC Manual 13-3 Siemens Hardware

178 Control Center DDE-Connection via a Network To establish a DDE-connection via a network, it is not required to start WinCC on the local computer. Note: The following description uses the terms client and server. The server is the computer on which WinCC is running. The local computer is the client, which accesses a WinCC tag from the server computer via the network. It is important to know under which operating system (Windows 95 or Windows NT 4.0) the client and the server operate. Additionally, note if WinCC is running as a single- or multi-user system on the server. To access a WinCC tag, follow these steps: The program "NetDDE.exe" must be started on both the client and the server. Windows 95: Under Windows 95, the program "NetDDE.exe" must be included in the start-up folder. The " NetDDE.exe" program is located in the path, in which Windows 95 has been installed (e.g. " C:\WIN95" or "C:\WINDOWS"). Windows NT 4.0: Method 1: Include the program "NetDDE.exe" in the start-up folder. The "NetDDE.exe" program is located in the path, in which Windows NT 4.0 has been installed (e.g. "C:\WINNT\SYSTEM32"). Method 2: Under Windows NT 4.x, the NetDDE has been integrated as a system service and been set with the start type Manual. The start type Manual has the following effect: The system service will only be started, if a corresponding request is made by a program (e.g. WinCC). If the server uses Windows NT 4.0 and WinCC has been installed as a multi-user system, it is not required to change the default start type (Manual) of the system service. If a WinCC multi-user system is run on a Windows NT computer, the NetDDE system service will automatically be started once runtime is activated. If a WinCC single-user system is run on a Windows NT computer, the NetDDE system service will not automatically be started once runtime is activated. To activate this system service, double click on Services in the control panel. The Services dialog will be displayed. Select the Network- DDE-Service entry from the dialog and click on the Start button. Windows NT will then attempt to start the system service WinCC Manual

179 08.97 Control Center "Services" dialog window under Windows NT 4.0 A DDE-share must be configured on the client and the server via the "DDEShare.exe" program. Windows 95: Under Windows 95, the "DDEShare.exe" program must be started and configured as follows: On the task bar, click on "Start" and then on Run. In the Run dialog window, enter the text "DDEShare.exe" in the Open entry field and click on "OK". Within the "Network DDE Share Manager" dialog window, a DDE-share can be configured via the < F2 > function key or via the "Share" menu and "New" entry. The following values must be entered: in the "Share Name" entry field enter "PROJECT", in the "Application Name" entry field enter "WINCC", and in the "Topic Name" entry field enter "project". WinCC Manual 13-5 Siemens Hardware

180 Control Center "Share Properties" dialog window under Windows 95 Windows NT 4.0: Under Windows NT 4.0, the "DDEShare.exe" program must be started and configured as follows: On the task bar, click on "Start" and then on Run. In the Run dialog window, enter the text "DDEShare.exe" in the Open entry field and click on "OK". Within the dialog window "DDE-Share on <Computer Name>", a DDE-share can be configured via the "Share" menu and the "DDE-Shares" entry. Activate the button Add a Share. The following values must be entered in the DDE-Share Properties dialog window: In the "Share Name entry field enter "PROJECT", in the "Static" entry field under "Application Name" enter "WINCC", and in the "Static" entry field under "Topic Name" enter "project" WinCC Manual

181 08.97 Control Center "DDE-Share Properties" dialog window under Windows NT 4.0 Select the newly created DDE-share in the DDE-Shares dialog window and click on the Trust-Share button. Activate the Initiate to Application Enable check-box in the Trusted-Share Properties dialog window. Click on the buttons Set and OK to accept the settings. "Trusted-Share Properties" dialog window under Windows NT 4.0 WinCC Manual 13-7 Siemens Hardware

182 Control Center Within Excel, a WinCC tag can be integrated in the following way: Activate the Excel program. Select the cell, in which you want to display the value of the WinCC tag. Enter an equal sign = in the Excel formula bar. Enter the following text after the equal sign: '\\CmputerName\ndde$' PROJECT!DDEVar1 The ComputerName entry must be replaced by a valid computer name (e.g. \\WINCC_SERVER). Note that the \\ComputerName\ndde$ entry must be enclosed by single quotation marks. This example displays an Excel table. The value of the WinCC tag DDEVar1, which is contained on the computer \\DIS_BULSTí project, will be displayed in cell A WinCC Manual

183 08.97 Control Center 13.5 Special DDE-Connection to Excel This chapter describes how WinCC tags can be placed in several tables of an Excel workbook. The following description illustrates how a WinCC tag can be updated from Excel in runtime. It is also possible to update a WinCC tag in Excel from the WinCC runtime. The following requirements must be met before a WinCC tag within an Excel book can be addressed. A connection must be configured (e.g. "EXCEL_1") within the communication driver Windows DDE". For this connection, the following addressing, within the DDE-Connection tab, is required: Computer Name Application Topic the current computer name (optional) Excel [dde.xls]table1 Note: The "Excel" entry under Application is required. This entry sets the name of the required application. The entries under Topic have the following meaning: The complete name of the desired Excel file must be entered within the square brackets. Immediately following the file name, the "Table1" entry, where the value 1 can be replaced by any other number, must be entered. The Table1 entry determines the memory location within an Excel book. Within the connection (e.g. "EXCEL_1") a new tag must be created (e.g. "dde_bool1" of the data type "Binary Tag"). While creating the tag, activate the Select button in the General Information tab. The "Address Properties" dialog window will be displayed. Select the "DDE- Tag" tab and enter the position values (Excel manages all values via rows, which in turn are divided into rows and columns) for the Excel table in the "Tag Name" field (e.g. "z1s1", this means z1=row 1 and s1=column 1 within the table). Determine the required data type via the " Data Type" field. Open Excel and create a blank workbook which must be saved under the name (e.g. "dde.xls") entered within the square brackets of the Topic field of the Connection Properties dialog of the DDE-Connection. Note: If you created the file "dde.xls" in Excel via the Save As command, you can continue to work in Excel and read in the WinCC tag values. To have Excel automatically open the required workbook (e.g. "dde.xls") while WinCC runtime is activated, make the following settings in the computer start-up list: Switch to the WinCC Control Center and select the required computer under the Computer project component. Activate the Computer Properties dialog window via the context menu entry "Properties" WinCC Manual 13-9 Siemens Hardware

184 Control Center Switch to the "Start-Up" tab and click on the "Add" button to display the "Add Application" dialog. In the "Application" field, enter the complete program path and name of Microsoft Excel or the corresponding link (e.g. "C:\MSOffice\Excel\EXCEL.EXE "). In the "Parameter" field, the complete program path and name of the Excel workbook must be entered (e.g. "D:\Project\DDEFolder\dde.xls"). Note: If you activate Excel and the workbook via the computer start-up tab, note the following: If the workbook (e.g. "dde.xls") is loaded, the data contained in the workbook will be transferred to the WinCC runtime system and be processed. Additionally, note that before activating runtime, the Excel workbook (e.g. "dde.xls") should not be open, otherwise the workbook would be opened write-protected. This example shows the interaction of Excel, the WinCC Control Center, and the WinCC Runtime System WinCC Manual

185 08.97 Control Center 14 Find Function In the Context Menu 14.1 Preparing Search Conditions General Information: You can set the start of the search within the project navigation window. Select the point from which the search starts. This way you can limit the search result. How to Find Objects or Tags: Note: This help tool is offered in all of the context menus of the Control Center. 1. In the project window, click the right mouse button on a list or an object, or click on an empty space in the data window. 2. In the context menu that then appears, click on the "Find " menu item. 3. In the window that then appears, you can enter your search conditions in one of several tabs. Tab Name Date of Change Additional Options Explanation Enter the term you want to find. Enter the date of change to further limit the search conditions for the objects. You can limit the search conditions even further in this tab. WinCC Manual 14-1 Siemens Hardware

186 Control Center If you have entered the term you want to find, click the "Start," or "New Search" button. This selection activates the find function "Name" Tab How to Edit the "Find What?" Input Box: Note: The search terms you entered are available only during WinCC run time. 1. Click on the "Find What?" box and enter the name of the object that you want to find. In this example, the system is searching for the " NewTag" object. 2. Click on the button and select the name of the object you want to find. The names displayed are only available at run time in the Control Center. In this example, the system has already searched for the " NewTag" and "*.RPL" objects. 3. Once you have entered the name, click the "Start" or "New Search" button to activate the find function WinCC Manual

187 08.97 Control Center "Date of Change" Tab How to Change the Options in the "Date of Change" Tab: 1. Click on the "Date of Change" tab. 2. The default setting is "All objects." 3. You can choose between the following two main groups: "All objects" "All objects that were created or changed" 4. Activate the individual options by clicking on the option button. How to Use the "Date of Change" Tab to Find All Objects: 1. Click on the "Date of Change" tab. 2. Click on the "All objects" option button. Note: All of the entries you made in the "All objects that were created or changed" area are not considered during the search. 3. Once you have entered the name of the object you are searching for, click the "Start" or "New Search" button to activate the find function. WinCC Manual 14-3 Siemens Hardware

188 Control Center How to Use the "Date of Change" Tab to Find All Objects That Were Created or Changed: 1. Click on the "Date of Change" tab. 2. Click on the "All objects that were created or changed" option button. 3. You can search in one of the following three time frames: Between Within the last month(s) Within the last day(s) How to Use the "Date of Change" Tab to Find an Object that was Created or Changed Within a Specific Time Frame: 1. Click on the "Date of Change" tab. 2. Click on the "Between" option button. 3. You can now enter a time frame in which to search. 4. Once you have entered the name of the object you want to find, click the "Start" or "New Search" button to activate the find function. How to Use the "Date of Change" Tab to Find an Object That Was Created or Changed Within the Last Month(s): 1. Click on the "Date of Change" tab. 2. Click on the "Within the last month(s)" option button. 3. You can enter a value between 1 and 12 manually or with the buttons. 4. Once you have entered the name of the object you want to find, click the "Start" or "New Search" button to activate the find function WinCC Manual

189 08.97 Control Center How to Use the "Date of Change" Tab to Find an Object That Was Created or Changed Within the Last Day(s): 1. Click on the "Date of Change" tab. 2. Click on the "Within the last day(s)" option button. 3. You can enter a value between 1 and 99 manually or with the buttons. 4. Once you have entered the name of the object you want to find, click the "Start" or "New Search" button to activate the find function "Additional Options" Tab How to Use the "Additional Options" Tab to Further Limit the Find Operation: 1. Click on the "Additional Options" tab. 2. Click on the button in the "Type" box and select the type you want to find. The default type setting is "All Object Types." 3. You can enter a parameter value for the selected type in the "Parameter Text" box. This parameter value limits the search even more. 4. Once you have entered the name of the object you want to find, click the "Start" or "New Search" button to activate the find function. WinCC Manual 14-5 Siemens Hardware

190 Control Center Starting the Find Procedure How to Start the Current Search or a New Search: 1. Once you have entered all of the terms you want to find, click on the "Start" or "New Search" button to activate the find process. 2. If the search for the object in the "Find What?" box is successful, the window is expanded and all of the objects found are displayed. 3. If you want to activate one of the objects found, you can double click on the appropriate object or use the right mouse button to open the pop-up menu and click the "Go To" button to select the object you choose in the project navigation window. 4. If you want to stop the search process, click on the "Stop" button WinCC Manual

191 08.97 Control Center 14.3 Stopping the Search Process How to Stop the Search Process That Is Running: 1. Click the "Stop" button. or Use the button in the upper right corner of the window to close the dialog box. 2. You can change the search conditions that you set and start a new search process. WinCC Manual 14-7 Siemens Hardware

192 Control Center WinCC Manual

193 08.97 Control Center 15 Appendix 15.1 Adapting the Formats of Data Types 15.2 Terms/Abbreviations In WinCC, you can convert certain data types to other data types by adapting the formats. You can find an explanation of the individual target data types in the corresponding technical literature. API C CEDST CET CP5412 A2 DCF77 DDE DLL DR DST GPS LAN MFC MMI ODBC ODK Application Programming Interface Higher programming language that was developed as a system development language (for example, for the UNIX operating system) and also as a universal programming language Central European Daylight Saving Time Central European Time PC plug in for connecting a PLC to the system bus Time signal transm itter in Frankfurt/Mainflingen, Germany. Provides the exact official time of the Federal Republic of Germany with a maximum deviation of 1 s in 1 million years. Dynamic Data Exchange Dynamic Link Library Drive letter of a storage medium (for example, "C" or "D" for a hard disk) Daylight Saving Time Global Positioning System - Satellite system which determines precise position on the earth. Individual GPS satellites circle the earth at an approximate height of 20,000 km on different paths. Each satellite contains a very precise atomic clock (precision of a minimum of 1 x ). The data transmitted by the satellites are used to calculate the time. Local Area Network Microsoft Foundation Classes Man-Machine Interface Open Database Connectivity WinCC Open Developers Kit (optional description of the programming interface) WinCC Manual 15-1 Siemens Hardware

194 Control Center OLE OLX OMS OS PDU PLC PMC RS232 RT RTC SQL ST Thread TIS UTC Wizard Object Linking and Embedding OLE Custom Controls Object Management System Operator Station Protocol Data Unit Programmable Logic Controller Process Monitoring Control Serial interface Run Time Real-Time Clock (battery backed CMOS clock chip in the PC) Structured Query Language, Data manipulation language for relational databases Standard Time A thread is a sub-function of a program that handles a very specific task. Test and Startup International time scale (Universal Time Coordinated) Auxiliary program for handling complex tasks (Assistant) 15-2 WinCC Manual

195 08.97 Control Documentation Control Center See Feedback Documentation A Alarm Logging See Editors in the Control Center aplip See Client-Server Functionality Automatic project start 2-4 C Channel-DLL See Communication Driver Channels See Communication Driver Channel-Unit See Channel-Unit Pop-up menu 8-1 Properties 8-5 Tab Connections 8-5 Tab General Information 8-6 SINEC-L2 8-1 System parameters 8-2; 8-3 CHN See Communication Driver Client-Server Functionality 1-6 Client-Server-List 6-1; 6-3 Communication Driver Channel-Unit 8-1 Connect to project 7-3 Delete from a project 7-3 File extension *.CHN 7-3 Installation 7-1 Logical connection 8-1 Pop-up menu 7-1 Properties 7-2 Within WinCC 7-1 Computer See Project Component Computerr Computer Name 6-1; 6-2 Computer Type 6-1; 6-2 Connection See Connection Create logical connection 9-1 Logical Connection 9-1 Properties 9-1 Tab Connection 9-4 Tab General Information 9-2 Tab Groups 9-3 Tab Tag 9-4 CP5412 See terms / abbreviations Create new project 2-1; 2-2 D Data Window See WinCC Project DDE-Server Dialog Field Lock writing 13-1 Dialog Field Server ready 13-1 Dialog Field Tag List 13-1 Dialog Window 13-1 General Information about the DDE-Server 13-1 Integrating tags 13-2 MS-Excel-Workbook 13-9 NetDDE.exe 13-4 Operating the DDE-Server 13-1 E Editors in the Control Center 12-1 Alarm Logging 12-2; 12-4 Global Scripts Graphics Designer Converting Pictures/Libraries Create new picture Linking new objects (OLL) Open picture Properties (Picture) Properties (Runtime) Report Designer 12-5 Create Print Job Delete layout Delete Print Job Layout Properties Layouts 12-7 New layout 12-8 Open layout 12-9 Preview Print Job Print Job Properties 12-16; 12-17; 12-18; 12-21; Print Jobs Print Print Job Properties 12-6 Renaming layout Renaming Print Job Tag Logging Text Library 12-4 User Administrator 12-2 Properties 12-3 End project 2-6 WinCC Manual Siemens Hardware Index-1

196 Control Center F Feedback Documentation... Print 1-13 View 1-13 Find Function (Pop-Up Menu) edit 14-1 Tab Additional Options 14-6 Tab Date of Change 14-3 Tab Name 14-2 Start Search 14-7 Stop Search 14-8 G Global Script See Editors in the Control Center Graphics Designer See Editors in the Control Center L Logical Connection See Connection Log-on and log-off the computer 2-6 M MCP See WinCC project MCP.EXE (Control Center) 1-7 Multi-user system 2-1 O OCX See Terms / Abbreviations ODBC See Terms / Abbreviations OLE See Terms / Abbreviations Online-Help...Contents Find Glossary Index Operation Tutorial 2-20 Open project 2-1; 2-3 P Preemtive Multi-Tasking 1-2 Print feedback documentation 2-5 Process control (runtime) 2-4 Production and Process Automation 1-2 Project See WinCC Project Project Component 5-1 Project Component Computer 5-1 Properties 6-1 Tab General Information 6-1 Tab Graphics Runtime 6-11 Tab Parameters 6-9 Tab Startup 6-3 Project Component Data types 5-4; Project Component Editor 5-5 Properties 5-6 Tag Management 5-3 Project Component Tag Management 5-2; 10-1 Project Window See WinCC Project Project-Navigation-Window See WinCC Project R Report Designer See Editors in the Control Center Runtime Information Connection 2-15 Multi-user system 2-17 Runtime-Cursor 6-13 Expanded 6-16 Normal wihout Rollback 6-15 Normal with rollback 6-15 S SCRIPTFCT See Client-Server Functionality Shut down the computer 2-6 SIMATIC S5 Ethernet TF 8-1 SINEC-L2 See Channel-Unit Single-user system 2-1 Start Picture 6-11 System Properties of WinCC 1-3 Index-2 WinCC Manual

197 08.97 Control Center T Tab Order/Alpha Cursor 6-13 Tag group See under WinCC-Tags See WinCC-Tags create 11-1; 11-2 cut, delete or copy 11-3 Properties 11-5 Tab General Information 11-6 Tab Tag 11-7 Tag Logging See Editors in the Control Center Tag Management See Project Component Tag Management Tags See WinCC-Tags Assigning names 10-1 Tasks of the Control Center 1-3 Tasks of the data manager 1-3 Terms / Abbreviations 15-1 Text Library See Editors in the Control Center U User Administrator See Editors in the Control Center V View feedback documentation 2-5 W WinCC Project Data Window 4-4 File Extension *.MCP 3-2 Project Properties 3-2 Tab General Information 3-3 Tab HotKeys 3-6 Tab Update Cycle 3-4 Project Window 4-1 Project-Navigation-Window 4-1 View/Edit 3-1 WinCC Runtime-Module (Additional Tasks/Applications) 6-5 WinCC Runtime-Module (by default) 6-4 WinCC-Channel 8-1 WinCC-Tags 10-1 Addressing a Structure Tag Addressing Process-Tags 10-32; copy 10-2; cut 10-2; delete 10-2; external 10-1 in a connection 10-3 in a tag group 10-4; 10-6 internal 10-1; 10-5 Name Change of a Structure Tag Naming conventions 10-1 Properties 10-7 Tab General Information 10-7; 10-9 Tab Limits/Reporting Raw Data 10-1 Standard data types 10-2; Binary Tag Data Type-BIT Floating Point Number 32-Bit IEEE ; Floating Point Number 64-Bit IEEE ; Raw Data 10-15; 10-24; Signed 16-Bit Value 10-15; Signed 32-Bit Value 10-15; Signed 8-Bit Value 10-15; Structure Types 10-15; Text Reference 10-15; Text Tag 16-Bit Character Set 10-15; Text Tag 8-Bit Character Set 10-15; Unsigned 16-Bit Value 10-15; Unsigned 32-Bit Value 10-15; Unsigned 8-Bit Value 10-15; Update 10-2 WinCC-Tags: Windows Control Center 1-1 Functionality 1-1; 1-3 Global Scripts 1-6 Menu Bar 1-10 Pop-Up Menus 1-12 Standard Editors 1-1 Status Bar 2-9 Structure 1-1; 1-4 Summary 1-1; 1-9 Toolbar 1-11; 2-9 WinCC Manual Siemens Hardware Index-3

198 Control Center Index-4 WinCC Manual

199 WinCC Channels Manual Edition August 1997 Siemens Hardware

200 WinCC, SIMATIC, SINEC, STEP are Siemens registered trademarks. All other product and system names in this manual are (registered) trademarks of their respective owners and must be treated accordingly. (The reproduction, transmission or use of this document or ist contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.) (We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed.) Siemens AG All rights reserved Technical data subject to change Printed in the Federal Republic of Germany Siemens Aktiengesellschaft

201 Table of Contents / Channels 1 Overview Requirements Procedure Configuring the Communication Driver SIMATIC S5 Serial 3964R Communication Driver Data Type of Tags Address of Tags S5-RK512 (3964R) Channel Unit SIMATIC S5 Programmers Port AS511 Communication Driver Data Type of Tags Address of Tags S5-AS511 Channel Unit SIMATIC S5 Ethernet Layer 4 Communication Driver Data Type of Tags Address of Tags System Parameters for S5 Transport (CP 1413-x) Channel Unit S5 Transport (CP 1413-x) Channel Unit SIMATIC S5 Ethernet TF Communication Driver Data Type of Tags Address of Tags System Parameters for S5 Application (CP 1413-x) Channel Unit S5 Application (CP 1413-x) Channel Unit SIMATIC S7 Protocol Suite Communication Driver Setting the logical Device Name Data Type of the Tags Address of Tags The Raw Data Tags of the S7 Communication Driver Data Exchange with S7 Function Blocks S7 MPI Channel Unit SINEC PROFIBUS Channel Unit SINEC Industrial EthernetChannel Unit SINEC-Slot PLC Channel Unit SINEC-TCP/IP Channel Unit WinCC Manual Siemens Hardware i

202 Channels SIMATIC TI505 Serial Communication Driver Data Type of Tags Address of Tags SIMATIC TI505 Unit #1 Channel Unit SIMATIC TI505 Ethernet Layer 4 Communication Driver Data Type of Tags Address of Tags System Parameters for the TI505 Ethernet (CP 1413-x) Channel Unit TI505 Ethernet (CP 1413-x) Channel Unit Windows DDE Communication Driver Data Type of Tags Address of Tags DDE Channel Unit ii WinCC Handbuch

203 08.97 Channels Preface Purpose of the Manual This manual introduces you to the functions of each software component and their operation in a reference manual format. You can find the information you need quickly by using the table of contents or the index. Naturally, the information is also available to you in the on-line help in either a context-sensitive fashion or in the on-line help contents. Total Overview and Configuration Example The "Getting Started" manual, which is part of the WinCC package, contains a total overview of WinCC and a configuration example in which the most significant functions of the individual components are followed through in a practical application. Additional Support If you have technical questions, please address them to your Siemens contact partner, located in the businesses responsible for your location. You can find the addresses in the attachment entitled Siemens Worldwide, in "S7-300 Automation System Structure in an S7-300," in catalogs, and on CompuServe (go.autforum). In addition, you may call our Hotline at (Fax 7001). You can find additional information on the Internet under the address Information about SIMATIC products Up to date information about SIMATIC products can be obtained: * from the Internet under * via fax# In addition, the SIMATIC Customer Support provides current information and downloads that can be beneficial for the utilization of SIMATIC products: * from the Internet under * via the SIMATIC Customer Support Mailbox under phone# +49 (911) * To address the mailbox, use a modem with up to V.34 (28.8 kbaud), which parameters must be set as follows: 8, N, 1, ANSI, or dial up through ISDN (x.75, 64 kbit). The SIMATIC Customer Support can be reached by phone under the number +49 (911) and by fax under the number +49 (911) Inquiries can also be made via Internet mail or mail addressed to the above mailbox. WinCC Manual Siemens Hardware iii

204 Channels iv WinCC Handbuch

205 08.97 Channels 1 Overview In this document, you will become acquainted with: The requirements that are necessary for accessing process tags by means of a programmable logic controller. The general procedure for connecting external tags. The specific configuration of a communication driver. Notes: In the Control Center Manual and in the on-line help for the Control Center, you will find detailed information on the operations necessary for implementing the process driver connection. This document provides you with supplementary information on the special features of the communication drivers used (tag addressing in the PLC and assignment of communication parameters for the logical connection). To implement the process driver connection, you need to have knowledge of the PLC and the communication being used. If you did not configure the PLC yourself, familiarize yourself with the technical documentation on this topic. In addition, the hardware required for communication as well as the drivers needed by the operating system must be completely installed already in the WinCC system. You should also consult the technical documentation to familiarize yourself with these items. WinCC Manual 1-1 Siemens Hardware

206 Channels WinCC Handbuch

207 08.97 Channels 2 Requirements From WinCC, you can access process tags (external tags) in a PLC. However, before you configure the process driver connection in WinCC, you should use a check list to see if the following requirements have been met: The PLC must be equipped with a communication interface that WinCC supports by means of a communication driver. This interface in the PLC must be properly configured such that the control program can access the interface by means of the communication calls. The configuration parameters for the communication hardware must be known. The addresses of the tags (depending on the PLC used) that WinCC is supposed to access must be known. The appropriate communication hardware (communication port COM1,... or module) must be installed in the WinCC system. If a module is installed, the accompanying operating system driver must have been installed. The hardware or software settings for the communication module must be known. Depending on the communication module you use in the WinCC system, you may have to make additional configurations for communication (such as creating a local database for Industrial Ethernet or PROFIBUS). These communication parameters must also be known. The following requirements must also be fulfilled in the RUNTIME mode to access tags: The PLC must be connected to the process. The physical connection between the PLC and the WinCC system must be installed and be functional. WinCC Manual 2-1 Siemens Hardware

208 Channels WinCC Handbuch

209 08.97 Channels 3 Procedure Process communication between the WinCC system and the PLC is structured as follows: If you want to connect external tags, you must proceed as follows: 1. Select the communication driver that supports the desired driver connections. Depending on the PLC that is connected, the communication driver contains one or more channel units. 2. Select the desired channel unit. 3. Configure a logical connection for the channel unit. 4. Define the tags or the tag groups with their tags and the system-specific addresses of the tags in each particular PLC. The address configuration for the communication driver used is explained in the section called "Configuring the Communication Driver". 5. Configure the communication-specific properties of the connection. This configuration is described in more detail for each particular channel unit in the section called "Configuring the Communication Driver". 6. Check the status of driver connections in the RUNTIME mode. You install the communication driver, configure a logical connection for a channel unit, and define the tag or tag group with the help of the Control Center. These procedures are described in detail in the Control Center Manual. WinCC Manual 3-1 Siemens Hardware

210 Channels Communication Driver To access external tags, you have to install the communication driver for the communication with the remote PLC. Depending on the driver, the communication driver contains one or more channel units. By means of the operating system interface and the hardware driver, a channel unit supports the hardware component (communication port or PC module) necessary for communication. Channel Unit (Driver Connection) The channel unit is a part of the communication driver. It is necessary for communication with the operating system interface of the communication hardware. The logical connections are operated by means of the channel unit. The logical connections provide access to the tags. Note: It is possible that a communication driver also has system parameters (such as device names or protocol parameters) for a channel unit. These parameters are handled separately for the channel units of the corresponding communication drivers. Logical Connection The logical connection handles the communication with the PLC that enables access to the external tags in the process. The name of the connection is unique. For the logical connection, you must define the tags of the remote PLC subsequently. You can configure individual tags as well as groups of tags. The address information necessary for configuration always refers to the PLC that you want to access by means of the logical connection. Finally, you must specify communication parameters for this connection (such as the bus address of the PLC). These parameters depend on the channel unit (driver connections) of the communication driver being used. The channel unit handles access to the communication interface of the operating system. You can call up and change the properties of the connection (configured groups, configured tags, and communication parameters). The Control Center (menu "Options" - "Status of Driver Connections") lets you check the status of driver connections in the RUNTIME mode. 3-2 WinCC Handbuch

211 08.97 Channels Group (Tag Group) A group (tag group) groups tags to make them easier to manage. In this group, you can configure tags that you can then access by means of the logical connection. You can call up and change the properties of the group (configured tags). Tag, Group Tag The analysis and control of the process is handled by tags that are stored at a defined address and in a specific length in the PLC. You configure these process values in WinCC as tags or group tags with a name, the data type, and the address in the PLC. For the standard data types, the length is derived implicitly from the type; for string tags, you must specify the length. The assignment to the PLC is made by means of the logical connection. For the logical connection, you specify the parameters that are necessary for the communication in a tab for specific communication. You can call up and change the properties of tags (data type, address, and, where necessary, length). WinCC Manual 3-3 Siemens Hardware

212 Channels WinCC Handbuch

213 08.97 Channels 4 Configuring the Communication Driver WinCC provides the following communication drivers for the process driver connection: SIMATIC S5 Serial 3964R for serial communication with SIMATIC S5 by means of the channel unit (driver connection): S5-RK512 (3964R) SIMATIC S5 Programmers Port AS511 for serial communication with SIMATIC S5 by means of the channel unit (driver connection): S5-AS511 SIMATIC S5 Ethernet Layer 4 for communication with SIMATIC S5 (Industrial Ethernet) by means of the channel unit (driver connections): S5-Transport (CP1413-1) (transport protocol of layer 4) S5-Transport (CP1413-2) (transport protocol of layer 4) SIMATIC S5 Ethernet TF for communication with SIMATIC S5 (Industrial Ethernet) by means of the channel units (driver connections): S5 Application (CP1413-1) (TF protocol of layer 7) S5 Application (CP1413-2) (TF protocol of layer 7) SIMATIC S7 Protocol Suite for communication with SIMATIC S7 by means of the channel units (driver connections): S7-MPI PROFIBUS Industrial Ethernet Slot PLC TCP/IP SIMATIC 505 Serial for serial communication with SIMATIC 505 by means of the channel unit (driver connection): 505 Unit #1 SIMATIC 505 Ethernet Layer 4 for communication with SIMATIC 505 (Industrial Ethernet) by means of the channel units (driver connections): 505-Ethernet (CP ) (transport protocol of layer 4) TI-Ethernet (CP ) (transport protocol of layer 4) WinCC Manual 4-1 Siemens Hardware

214 Channels Windows DDE for communication by means of a Windows DDE interface: DDE In addition to these communication drivers included with WinCC, the following communication drivers are available as options: PROFIBUS FMS for communication with PLCs by means of the channel unit (driver connection): PROFIBUS-FMS Allen Bradley Serial DF1 for communication with Allen Bradley by means of the channel unit (driver connection): AB 1 ModBus Serial for communication by means of the ModBus with the channel units (driver connections): Modbus Unit #1 Modbus Unit #2 Modbus Unit #3 Modbus Unit #4 Modbus Unit #5 Modbus Unit #6 Modbus Unit #7 Modbus Unit #8 Applicom Multi Protocol Interface for external connections (such as Télémécanique, ModBus,...) by means of the channel unit (driver connection): Applicom 1 SIPART DR for communication with the controllers DR19, DR20, DR21, DR22 and DR24 by means of the channel unit (driver connection): SIPART 4-2 WinCC Handbuch

215 08.97 Channels 4.1 SIMATIC S5 Serial 3964R Communication Driver This communication driver is used for the serial connection to a SIMATIC S5 PLC. Channel Unit This communication driver has a channel unit that makes it possible to operate a COM port for serial connection. The following application is available: Channel Unit S5-RK512 (3964R) for serial communication by means of the 3964R or 3964 protocol Data Type of Tags You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag Unsigned 8-bit value Signed 8-bit value Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number Text tag 8-bit character set WinCC Manual 4-3 Siemens Hardware

216 Channels Address of Tags You enter the tag address according to the address structure of SIMATIC S5. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the desired data type (for example, signed 8-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. 4. Select the Address tab. 5. In the "Data Area" box, select whether the tag is located in a data block, in an extended data block, in a bit memory (flag) area, or in an input or output area. 6. If the tag is in a data block, the "DB No." box is also displayed. Enter the number of the data block here. 7. The "Addressing" box indicates the type of addressing. Usually you can accept the default. 8. Enter the address in the appropriate box (for example, "DL"). 4-4 WinCC Handbuch

217 08.97 Channels Note: Do not use any data word addresses that are greater than 255. Because of a system property of the RK 512, only data word addresses from 0 to 255 are permitted. You can configure larger addresses; however, this results in data corruption on all configured tags of this connection. Access to the memory locations of a PLC can often take place only by byte or word. If binary or 8-Bit tags are used, the Address Properties dialog will contain an additional tab, through which individual bits, in the PLC s memory locations, can be changed. For that reason, every write instruction reads the addressed memory location from the PLC and changes the corresponding bits/bytes. Afterwards, the data is written back into the PLC. Note: Changes to the read data, made by the PLC, will be overwritten during the write back. Depending on the tag type, access, to the memory locations of a PLC, is carried out either by bit or by byte Setting the by Bit Access: 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Binary Tag data type. 3. Click on the Select button to open the Address Properties dialog. WinCC Manual 4-5 Siemens Hardware

218 Channels Via the checkbox, the By Bit accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed list box. Note: In the S5 PLC, markers, inputs, and outputs can be addressed by byte, and data blocks (DB, DX) can be addressed by word. Setting the by Byte Access 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Unsigned 8-Bit Value or Signed 8-Bit Value data type. 3. Click on the Select button to open the Address Properties dialog. 4. Via the checkbox, the By Byte accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed from the list box. 4-6 WinCC Handbuch

219 08.97 Channels S5-RK512 (3964R) Channel Unit The process driver connection by means of serial connection is possible with the SIMATIC S5 PLC. In the PLC, the CP 544 or a second plug-in serial interface is used on the CPU module (card slot SI2). No additional communication module is needed in the WinCC system. Communication takes place by means of one of the standard COM ports in the system. How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "Serial 3964R" tab. 3. In the "Interface" box, select the communication interface (COM1 or COM2) for serial connection. 4. In the "Procedure-Parameters" area, in the "Baud Rate" box, set the data transmission speed to the value used. You set the priority in the event of an initiation conflict (simultaneous send request from WinCC and the PLC) in the "Priority" box. Note: It is mandatory to set the priority to something different than is set for the SIMATIC S5. WinCC Manual 4-7 Siemens Hardware

220 Channels In the "Procedure Data" area, select either the "3964" or "3964R" transmission protocol. Default values for the procedure data (such as timeout and character delay time) should only be changed in exceptional cases. If you change them, make sure that they match the parameters in the PLC. 6. Now select the "Options" tab. 7. In the "Options" tab you can turn off the cyclic life-beat monitoring and suppress the automatic connection setup. 4-8 WinCC Handbuch

221 08.97 Channels 4.2 SIMATIC S5 Programmers Port AS511 Communication Driver This communication driver is used for serial connections to a SIMATIC S5 PLC by means of a TTY interface. Channel Unit This communication driver contains a channel unit that makes it possible to operate a COM port for serial connection. The following application is available: Channel Unit S5-AS511 for serial communication by means of a "Siemens-specific" protocol Data Type of Tags Address of Tags You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag Unsigned 8-bit value Signed 8-bit value Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number Text tag 8-bit character set You enter the tag address according to the address structure of SIMATIC S5. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the d esired data type (for example, signed 8-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. WinCC Manual 4-9 Siemens Hardware

222 Channels Select the "SYSVAR" tab. 5. Click on an option button to indicate whether the tag should transmit the type of controller ("PLC Type"), the current status ("PLC Status"), or other data ("PLC Data") WinCC Handbuch

223 08.97 Channels 6. If you select "PLC Data," you must also click on the "Address" tab to specify the S5 address of the tag. 7. Select the "Data Area," that is, whether the tag is in a data block, in an extended data block, in a bit memory (flag) area, or in the input or output area. 8. If the tag is in a data block, the "DB No." box is also displayed. Enter the number of the data block here. 9. The "Addressing" box indicates the type of addressing. Usually you can accept the default. 10. Enter the address in the appropriate box (for example, "DW"). Access to the memory locations of a PLC can often take place only by byte or word. If binary or 8-Bit tags are used, the Address Properties dialog will contain an additional tab, through which individual bits, in the PLC s memory locations, can be changed. For that reason, every write instruction reads the addressed memory location from the PLC and changes the corresponding bits/bytes. Afterwards, the data is written back into the PLC. Note: Changes to the read data, made by the PLC, will be overwritten during the write back. Depending on the tag type, access, to the memory locations of a PLC, is carried out either by bit or by byte WinCC Manual 4-11 Siemens Hardware

224 Channels Setting the by Bit Access: 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Binary Tag data type. 3. Click on the Select button to open the Address Properties dialog. 4. Via the checkbox, the By Bit accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed from the list box. Note: In the S5 PLC, markers, inputs, and outputs can be addressed by byte, and data blocks (DB, DX) can be addressed by word WinCC Handbuch

225 08.97 Channels Setting the by Byte Access 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Unsigned 8-Bit Value or Signed 8-Bit Value data type. 3. Click on the Select button to open the Address Properties dialog. 4. Via the checkbox, the By Byte accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed from the list box. WinCC Manual 4-13 Siemens Hardware

226 Channels S5-AS511 Channel Unit The process driver connection by means of serial connection is possible with the SIMATIC S5 PLC. The AS 511 communication processor is used in the PLC. No additional communication module is needed in the WinCC system. Communication takes place either by means of the TTY interface of a PG 760 programming device or by means of one of the standard COM ports in the system. In this case, a V.24/V.28 <---> TTY interface converter is necessary. How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "AS511" tab. 3. In the "Interface" box, select the communication interface (COM1 to COM4 or COMx) for serial connection. Note: Only if you select "COMx" as the interface can you make entries manually in the "I/O Port" and "Interrupt" boxes in the "Resources" area. In all other cases, the software specifies these values WinCC Handbuch

227 08.97 Channels 4.3 SIMATIC S5 Ethernet Layer 4 Communication Driver This communication driver is used for the connection to such PLCs as the SIMATIC S5-115U/H, SIMATIC S5-135U, and SIMATIC S5-155U/H by means of the ISO transport protocol. Channel Units This channel DLL has two channel units that make it possible to operate a maximum of two CP 1413 s. The functionality of the channel units is identical. They differ only in their logical device names. You can change the logical device name by means of the system parameters of the channel unit. Here you can also set the parameters for the ISO transport protocol. The following applications are available: Channel Unit S5 Transport (CP ) for the communication modules for SIMATIC Industrial Ethernet (such as CP 1413). Channel Unit S5 Transport (CP ) for the communication modules for SIMATIC Industrial Ethernet (such as CP 1413) Data Type of Tags You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag (read only) Unsigned 8-bit value Signed 8-bit value Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number Text tag 8-bit character set Raw data tag WinCC Manual 4-15 Siemens Hardware

228 Channels Address of Tags You enter the tag address according to the address structure of SIMATIC S5. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the desired data type (for example, signed 16-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. 4. Select the Address tab. 5. In the "Data Area" box, select whether the tag is located in a data block, in a bit memory (flag) area, or in an input or output area. 6. If the tag is in a data block, the "DB No." box is also displayed. Enter the number of the data block here. 7. The "Addressing" box indicates the type of addressing. Usually you can accept the default. 8. Enter the address in the appropriate box (for example, "DBW") WinCC Handbuch

229 08.97 Channels Note: If the tag of a word-oriented data area is to be written, the start address must be in the left byte and the length of the tag must be an even number. Access to the memory locations of a PLC can often take place only by byte or word. If binary or 8-Bit tags are used, the Address Properties dialog will contain an additional tab, through which individual bits, in the PLC s memory locations, can be changed. For that reason, every write instruction reads the addressed memory location from the PLC and changes the corresponding bits/bytes. Afterwards, the data is written back into the PLC. Changes to the read data, made by the PLC, will be overwritten during the write back. Depending on the tag type, access, to the memory locations of a PLC, is carried out either by bit or by byte Setting the by Bit Access: 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Binary Tag data type. 3. Click on the Select button to open the Address Properties dialog. WinCC Manual 4-17 Siemens Hardware

230 Channels Via the checkbox, the By Bit accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed list box. Note: In the S5 PLC, markers, inputs, and outputs can be addressed by byte, and data blocks (DB, DX) can be addressed by word. Setting the by Byte Access 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Unsigned 8-Bit Value or Signed 8-Bit Value data type. 3. Click on the Select button to open the Address Properties dialog. 4. Via the checkbox, the By Byte accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed from the list box WinCC Handbuch

231 08.97 Channels System Parameters for S5 Transport (CP 1413-x) Channel Unit The process driver connection by means of the Industrial Ethernet is possible with the SIMATIC S5-115U/H, S5-135U, and S5-155U/H PLCs. The communication module CP 1430 TF is used in the PLC. Communication takes place by means of the ISO transport protocol. The communication module CP 1413 is used in the WinCC system. Because communication takes place by means of the ISO transport protocol, it is not necessary to configure the logical connection in the local database. How to Configure the System Parameters: 1. Select the channel unit and use the pop-up menu to open the "System Parameters" dialog box. 2. Select the "Device Names" tab. 3. Select the device name displayed in bold type and click in the name box to change the device name. Note: The device name is specified when the hardware driver is installed. Only if you assigned a different name then (which, however, is not a good idea) do you have to change the device name here also. WinCC Manual 4-19 Siemens Hardware

232 Channels Select the "Transport Parameters" tab. 5. Set the value in the "PDU Size" box to the value that was also configured on the CP 1430 TF. 6. In the "Setup Attempts" box, specify how often an attempt should be made to set up a connection. 7. In the "Duration of Send Repetitions" area, select "Infinite." 8. In the "Acknowledgment Time" box, enter the value 30 so that you are informed after no more than 30 seconds by means of the tag status that the remote PLC did not answer within this time (for example, PLC is in the STOP mode) WinCC Handbuch

233 08.97 Channels S5 Transport (CP 1413-x) Channel Unit For a logical connection, WinCC sets up one connection each for reading (READ) and writing (WRITE) in the transport layer. The logical connection is not designated as set up until both of these connections have been established. How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "Connection" tab. 3. In the "Ethernet Address Controller" box, enter the station address of the SIMATIC S5 on the Industrial Ethernet bus. 4. Specify the parameters for the READ function in the WinCC system. They depend on the request used in the SIMATIC S5. WinCC Side FETCH Active (Request "READ Active") FETCH Passive (Request "WRITE Passive") SIMATIC S5 Side READ Passive (Request "READ Passive") WRITE Active (Request "WRITE Active") WinCC Manual 4-21 Siemens Hardware

234 Channels In the "Own TSAP-ID" box, enter the value that was configured for the CP 1430 TF as "TSAP" under the heading of "Remote Parameters." 6. In the "External TSAP-ID" box, enter the value that was configured for the CP 1430 TF as "TSAP" under the heading of "Local Parameters." 7. Enter the appropriate parameters for "Own TSAP-ID" and "External TSAP-ID" for the WRITE function. WinCC Side Request "WRITE Active" SIMATIC S5 Side Request "WRITE Passive" 4.4 SIMATIC S5 Ethernet TF Communication Driver This communication driver is used for the connection to the SIMATIC S5-115U/H, SIMATIC S5-135U, and SIMATIC S5-155U/H PLCs by means of the Industrial Ethernet with the TF (Technological Functions) protocol. Channel Units This channel DLL has two channel units that make it possible to operate a maximum of two CP 1413 s. The functionality of the channel units is identical. They differ only in their logical device names. You can change the logical device name by means of the system parameters of the channel unit. The following applications are available: Channel unit S5 application (CP ) for the communication modules for SIMATIC NET Industrial Ethernet (for example, CP 1413). Channel unit S5 application (CP ) for the communication modules for SIMATIC NET Industrial Ethernet (for example, CP 1413) Data Type of Tags You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag (read only) Unsigned 8-bit value Signed 8-bit value Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number Text tag 8-bit character set 4-22 WinCC Handbuch

235 08.97 Channels Address of Tags You enter the tag address according to the address structure of SIMATIC S5. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the desired data type (for example, signed 32-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. 4. In the "CPU" box, select the CPU in which the data area for the tag is located. 5. In the "Data Area" box, select whether the tag is located in a data block, in an extended data block, in a bit memory (flag) area, or in an input or output area. 6. If the tag is in a data block, the "DB No." box is also displayed. Enter the number of the data block here. 7. The "Addressing" box indicates the type of addressing. Usually you can accept the default. 8. Enter the address in the appropriate box (for example, "DD"). WinCC Manual 4-23 Siemens Hardware

236 Channels Note: If the tag of a word-oriented data area is to be written, the start address must be in the left byte and the length of the tag must be an even number System Parameters for S5 Application (CP 1413-x) Channel Unit The process driver connection by means of Industrial Ethernet is possible with the SIMATIC S5-115U/H, S5-135U, and S5-155U/H PLCs. The communication module CP 1430 TF is used in the PLC. Communication takes place by means of the TF protocol. The communication module CP 1413 is used in the WinCC system. The logical connection must be configured in the local database. How to Configure the System Parameters: 1. Select the channel unit and use the pop-up menu to open the "System Parameters" dialog box. 2. The "System Parameters" dialog box with the "Device Names" tab opens. 3. Select the device name displayed in bold type and click in the name box to change the device name. Note: The device name is specified when the hardware driver is installed. Only if you assigned a different name then (which, however, is not a good idea) do you have to change the device name here also WinCC Handbuch

237 08.97 Channels S5 Application (CP 1413-x) Channel Unit How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "TF Connection" tab. 3. In the "Name" box, enter the name of the application relationship. Note: The name of the application relationship must be configured in the WinCC system in the local database. To do this, use the "COML 1413 TF" program from the "TF-NET 1413/Windows 95" or "TF-NET 1413/Windows NT" package. You also specify your own TSAP-IDs and external TSAP-IDs here. For example, for a connection to SIMATIC S5, these IDs must correspond to the "TSAP" values under the headings "Remote Parameters" and "Local Parameters" from the configuration of the CP 1430 in SIMATIC S5. 4. In the "Type Remote" box, select the remote PLC for communication. WinCC Manual 4-25 Siemens Hardware

238 Channels In the "Setup Type Layer 7," specify the connection that should be set up in the application layer. Note: This value must be configured similarly in the remote PLC system. The following variants in setup type are permitted: WinCC None Active Passive Remote PLC System None Passive Active 6. Select the check box "Remote is GRACIS" in case the remote PLC system is a GRACIS system and enter the "Node ID" in the appropriate box. 4.5 SIMATIC S7 Protocol Suite Communication Driver The communication driver is used for connecting to the SIMATIC S7-300 and SIMATIC S7-400 PLCs, and contains five different channel units. Channel Units Depending on the installed WinCC communication hardware, the following applications are available: MPI for connecting via an internal MPI interface (e.g. PG 760/PC RI45) or MPI module, as well as the communication component CP 5511 (PCMCIA card), PROFIBUS for the communication modules of the SIMATIC NET PROFIBUS (e.g. CP 5412/A2), Industrial Ethernet for the communication modules of the SIMATIC NET Industrial Ethernet (e.g. CP 1413). Slot PLC for the communication to the PLC card, which is a PC card located in your PC. TCP/IP for the communication via networks with a TCP/IP protocol WinCC Handbuch

239 08.97 Channels Setting the logical Device Name Communicating to the S7 takes place via the logical Device Name. This name will be assigned during the installation of the communication card. Depending on the installed communication card, the following pre-defined settings have been established: MPI-Unit: MPI PROFIBUS Unit: CP_L2_1 Industrial Ethernet Unit: CP_H1_1 Slot-PLC Unit: Slot-PLC TCP/IP Unit: CP-TCPIP If a communication card is used, which does not support these name conventions, the preset logical device names can be changed in the System Parameter dialog of the channel unit. Changing the logical Device Name of a Channel Unit From the pop-up menu of the channel unit, select the System Parameter entry. The dialogs for setting the system parameters are identical for all channel unit types. The following example explains the System Parameter - S7-MPI dialog. WinCC Manual 4-27 Siemens Hardware

240 Channels Field CP-Type/Bus Profile Logical Device Name set automatically Explanation Displays the selected channel unit type. Enter the logical device name either directly or select one from the list box. If this checkbox is selected, starting runtime will initiate a check to see if only one communication card is installed for this communication type. If this is the case, the configured name of the channel unit will be replaced by the existing one. If a logical device name is selected, which is not contained in the list box, the system will display the following message: Click on OK to accept the selected device name. The available device names (that can be selected from the list-box) are determined by the Setting the PG/PC Interface tool, located in the Windows95/NT4.0 Control Panel. If this tool is not installed, only the currently entered device name will be displayed. If you set a different logical device name, the following message will be displayed: 4-28 WinCC Handbuch

241 08.97 Channels Data Type of the Tags Define the necessary tags for a logical connection. The following data types are available in WinCC: Binary tag Unsigned 8-bit value Signed 8-bit value Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number 62-bit IEEE 754 floating-point number Text tag 8-bit character set Text tag 16-bit character set Raw data tag WinCC Manual 4-29 Siemens Hardware

242 Channels Address of Tags Enter the tag address according to the address structure of SIMATIC S7. How to Enter the Tag Address: 1. Right mouse button click on the desired tag to open its pop-up menu, and click on "Properties" to display the Tag Properties dialog window. 2. In the "General Information" tab, select the desired data type (e.g. signed 16-bit value). 3. Click on the "Select" button - the "Address Properties" dialog will open: 4. In the "Data Area" field, select whether the tag is to be located in a data block, a bit memory (flag) area, or an input/output area. 5. If the tag is located in a data block, the "DB No." field will also be displayed - enter the data block number in this field. 6. Select the addressing type in the "Addressing" field. In most cases the default address can be accepted. 7. Enter the word-address in the corresponding field (e.g. "DBW"). 8. If the tag is of the Binary type, enter the bit address in the Bit field WinCC Handbuch

243 08.97 Channels How to Enter the Address of a Tag of the Raw Data Type: 1. Right mouse button click on the desired tag to open its pop-up menu, and click on "Properties" to display the Tag Properties dialog window. 2. In the "General Information" tab, select the "Raw Data Type" from the "Data Type" list box. 3. Click on the "Select" button - the "Address Properties" dialog will open: 4. In the "Data Area" field, select whether the tag is to be located in a data block, a bit memory (flag) area, or an input/output area. 5. If the tag is located in a data block, the "DB No." field will also be displayed - enter the data block number in this field. 6. Select the addressing type in the "Addressing" field. In most cases the default address can be accepted. 7. Enter the address in the corresponding field (e.g. "DBB"). 8. If necessary, specify the length of the raw data block in the "Length" field. Note: The length of the raw data is limited to one data block - it must be possible to completely transfer one raw data block with one PDU (Protocol Data Unit). WinCC Manual 4-31 Siemens Hardware

244 Channels The length of the data blocks that can be transmitted by the S7 communication driver is determined by the block length set during connection setup minus the header and additional information. The following PDU lengths are currently used for SIMATIC S7: PDU length 240 Bytes (S7-300): raw data block maximum 208 Bytes PDU length 480 Bytes (S7-400): raw data block maximum 448 Bytes If you use a S with a SAPI-S7, the raw data block length is limited to a maximum of 224 Bytes. If an invalid block length is entered, a message will be displayed indicating that your read/write request has been rejected The Raw Data Tags of the S7 Communication Driver In addition to the process tags, the data manager also manages raw data tags. The S7 communication driver differentiates between two types of raw data tags. Raw data tag for a user-defined application (e.g. BSEND/BRCV data blocks) Raw data tag for processing S7 functions (e.g. message processing) The raw data tags for processing S7 functions contain S7 specific header and are generally used by the WinCC message and the process data recording systems. To use raw data tags for processing S7 functions, a S7-PMC license is required. The raw data tags for user-defined applications are used to transfer user data blocks from and to the automation system. These raw data tags only handle user data. Raw Data Tags for User-Defined Applications: The S7 communication driver currently supports two functionalities for raw data tags for user-defined applications: Raw data tag as Byte-Array Raw data tag for BSEND/BRCV functions 4-32 WinCC Handbuch

245 08.97 Channels Raw Data Tag as Byte-Array A raw data tag as a Byte-Array corresponds to a regular process tag in the eyes of the S7 channel, and is handled like a process tag by the S7 channel. The Byte-Array can be addressed via an ANY pointer (e.g. DB 100, DW 20 Length 40 Byte). The maximum length of the data blocks that can be transferred by the communication driver depends on the sustained block length, minus the header and supplementary information, achieved after the connection has been established. This results in the following maximum lengths for the usual S7 PDU lengths: PDU-Length 240 Bytes (usual for AS300): 208 Bytes PDU-Length 480 Bytes (usual for AS400): 448 Bytes Warning: If the SAPI-S7 is used, the maximum data block is limited to 224 Bytes! If larger data blocks are to be transferred, the user must carry out the blocking of the data himself. WinCC Manual 4-33 Siemens Hardware

246 Channels Configuration of a Raw Data Tag as a Byte-Array The raw data tags for transferring data blocks are configured as raw data of the type Block send/receive and include an address and length indication. Example of a configuration for a data range 40 Bytes long in data block 100, starting from data word 20: Reading a Raw Data Tag as a Byte-Array The process of reading a raw data tag as a Byte-Array is the same as the reading of a regular process tag. The corresponding data block is requested by the PLC and will be transferred to the user, once the data has been received. A transfer is always initiated by WinCC. A sporadic or event-driven data receival initiated by the PLC is not possible via a raw data tag. Writing to a Raw Data Tag as a Byte-Array The process of writing a raw data tag as a Byte-Array is the same as the writing of a regular process tag. After sending the data block and the receival of a positive acknowledgment by the PLC, the data block will be transferred to the image of the data manager. Since this is a tag change, all applications, requesting this tag, will be continued with the changed tag WinCC Handbuch

247 08.97 Channels Raw Data Tag for PBK BSEND/BRCV Functions This type of raw data tag allows you to use the PBK functions BSEND/BRCV. These functions are currently only available for the AS400 (not for the AS300!!!). The BSEND/BRCV functions allow you to exchange data blocks, with a length of up to 16 Kbytes, with the PLC via S7DOS. The partner sending data always initiates the data transfer, which allows the realization of sporadic or event-driven data block transfers via the BSEND/BRCV functions. The BSEND/BRCV functionality is not supported by the SAPI-S7! Configuration of a BSEND/BRCV Connection The BSEND/BRCV functions can only be used via a fixed, configured connection. To configure this connection, a connection resource (Hexa: DF) must be indicated. This connection resource will be assigned by STEP7 during the configuration of the connection to the PLC. On the PLC side, the connection must be configured as a passive connection end point. Example of a connection configuration for an H1 connection: Via a fixed, configured connection, regular read and write requests can also be carried out. If very large data ranges are being transferred, the data blocks will be transferred into multiple PDUs. For performance reasons, it might be practical to create a specific connection for the BSEND/BRCV functions. WinCC Manual 4-35 Siemens Hardware

248 Channels Raw Data Tag for BSEND/BRCV Functions The raw data tags for transferring BSEND/BRCV data blocks are configured as raw data of the type BSEND/BRCV with a R_ID. The data length results implicitly from the sent/received data amount. Example of a configuration of a BSEND/BRCV raw data tag: For the BSEND/BRCV functionality, a 32 Bit long R_ID must be indicated as a hexadecimal number. The R_ID serves for the differentiation of multiple data block transfers via one connection. The send and receive calls to the subordinated communication sub-system (S7DOS) are always indicated in reference to the R_ID. A raw data tag, therefore, is always assigned to an unique R_ID. For resource reasons, the number of BSEND/BRCV raw data tags should be kept small WinCC Handbuch

249 08.97 Channels Receiving a BSEND/BRCV Raw Data Tag BSEND/BRCV raw data is sent sporadically to the communication driver, because of the PLC initiative. An explicit reading of S7 raw data tags is therefore not possible. The BSEND/BRCV functionality contains no functions for the synchronization. If, during the start-up phase, no user has logged on to receive the data, the data blocks sent by the PLC will be discarded. The user has to take care of the synchronization himself, e.g. enable the sending direction to the PLC by setting flags in a data word. Sending a BSEND/BRCV Raw Data Tag The process of sending a BSEND/BRCV raw data tag is the same as the writing of a regular process tag. After sending the data block and the receival of a positive acknowledgment by the PLC, the data block will be transferred to the image of the data manager Data Exchange with S7 Function Blocks To transfer process data to a WinCC measured value archive via the S7 CPU s integrated function block SFB 37 AR_SEND, the data has to be prepared in a specific WinCC format. Such a data telegram can be divided into two sections: The header contains information about the cycle, the process values, and possibly a time stamp. The user data area contains the actual process values. The size of the user data area is limited to a maximum of Bytes. WinCC Manual 4-37 Siemens Hardware

250 Channels Header Type Time Stamp Cycle Unit (Type) Unit (Area) Process Values The header type determines whether the data block header contains a time stamp or not. Header Type = 0: Header contains no time stamp Header Type = : Header contains no time stamp The time stamp contains the date and time in the SIMATIC-S7-BCD format. The weekday entry is not utilized by WinCC. Cycle - in which the process values are read - in time units. 1 The process values are read in equal time intervals. 2 Each process value contains a time stamp. 3 Each process value contains a time difference in time units. Displays the size of the time units used for the unit (type) = 3 1 reserved 2 reserved 3 Milliseconds 4 Seconds 5 Minutes 6 Hours 7 Days The process values are directly stored in the S7 format. Number of the following process values Unit (Type) = 1 Unit (Type) = 2 Unit (Type) = 3 The process values are read in equal time intervals: The maximum size of the user data area is Bytes. This allows the transfer of 8000 process values of the data type WORD or INT, or the transfer of 4000 process values of the data type DWORD, DINT or REAL. A time stamp entry in the header is required. Process values with time stamps: Each element in the user data area consists of a time stamp (8 Bytes) and a value. This allows the transfer of 1600 process values of the data type WORD or INT, or the transfer of 1333 process values of the data type DWORD, DINT or REAL. A time stamp entered in the header will not be valued. Process values with time difference: Each element of the user data area consists of a time difference (4 Bytes) and a value. This allows the transfer of 2666 process values of the data type WORD or INT, or the transfer of 2000 process values of the data type DWORD, DINT or REAL. A time stamp entry in the header is required WinCC Handbuch

251 08.97 Channels S7 MPI Channel Unit The S7-300 PLC either uses its internal MPI interface and/or the CP module. The S7-400 PLC either uses its internal MPI interface and/or the CP module. If WinCC is installed on a PG 760/PC RI45, the internal MPI interface can also be used; otherwise, the MPI module must be installed. Alternatively, the CP 5511 (PCMCIA card) can be used. How to Configure the Communication Parameters: 1. Click on the desired connection and select Properties from the pop-up menu (a right mouse button click opens the pop-up menu). 2. Select the "Connection" tab. 3. In the "Station Address" field, enter the bus station address of the SIMATIC S7. 4. Currently, the "Segment ID" field is not supported - the value must remain at "0". 5. If an external communication processor (e.g. CP 443-5) is used, enter the rack number of the CPU to be addressed in the Rack Number field. For an internal MPI interface of a CPU: Rack Number = 0. WinCC Manual 4-39 Siemens Hardware

252 Channels If an external communication processor (e.g. CP 443-5) is used, enter the slot number of the CPU in the "Slot Number" field. For an internal MPI interface of a CPU: Slot Number = If you activated the check-box Send/receive raw data block, a connection resource must be indicated. Note: If an invalid rack or slot number is entered, the communication connection will not be set up SINEC PROFIBUS Channel Unit The S7-300 PLC uses the CP module. The S7-400 PLC uses the CP module. The WinCC system uses the CP 5412/A2 communication module. How to Configure the Communication Parameters: 1. Click on the desired connection and select Properties from the pop-up menu (a right mouse button click opens the pop-up menu). 2. Select the "Connection" tab. 3. In the "Station Address" field, enter the bus station address of the SIMATIC S WinCC Handbuch

253 08.97 Channels 4. Currently, the "Segment ID" field is not supported - the value must remain at "0". 5. In the "Rack Number" field, enter the rack number of the CPU to be addressed. 6. In the "Slot Number" field, enter the slot number of the CPU. 7. If you activated the check-box Send/receive raw data block, a connection resource must be indicated. Note: If an invalid rack or slot number is entered, the communication connection will not be set up SINEC Industrial EthernetChannel Unit The process driver connection via the Industrial Ethernet is only possible with the S7-400 PLC - this PLC uses the CP module. Because communication takes place via the ISO transport protocol, the CP SEND/RECEIVE interface is used. The WinCC system uses the CP 1413 communication module. Because communication takes place via the ISO transport protocol, it is not necessary to configure the logical connection in the local database. WinCC Manual 4-41 Siemens Hardware

254 Channels How to Configure the Communication Parameters: 1. Click on the desired connection and select Properties from the pop-up menu (a right mouse button click opens the pop-up menu). 2. Select the "Connection" tab. 3. In the "Ethernet Address" field, enter the Industrial Ethernet bus station address of the SIMATIC S7. 4. In the "Rack Number" field, enter the rack number of the CPU to be addressed. 5. In the "Slot Number" field, enter the slot number of the CPU. 6. If you activated the check-box Send/receive raw data block, a connection resource must be indicated. Note: If an invalid rack or slot number is entered, the communication connection will not be set up. During the configuration of the CP 443-1, do not specify any connection requests to the WinCC system WinCC Handbuch

255 08.97 Channels SINEC-Slot PLC Channel Unit The process connection SINEC- Slot-PLC Channel Unit serves for the communication to the built-in PLC card. How to Configure the Communication Parameters: 1. Click on the desired connection and select Properties from the pop-up menu (a right mouse button click opens the pop-up menu). 2. Select the "Connection" tab. 3. If you activated the check-box Send/receive raw data block, a connection resource must be indicated. WinCC Manual 4-43 Siemens Hardware

256 Channels SINEC-TCP/IP Channel Unit The process connection SINEC-TCP/IP Channel Unit serves for the communication via networks using a TCP/IP protocol. How to Configure the Communication Parameters: 1. Click on the desired connection and select Properties from the pop-up menu (a right mouse button click opens the pop-up menu). 2. Select the "Connection" tab. 3. Enter the Internet protocol address of the SIMATIC S7 at the TCP/IP bus in the IP Address field. 4. In the "Rack Number" field, enter the rack number of the CPU to be addressed. 5. In the "Slot Number" field, enter the slot number of the CPU. 6. If you activated the check-box Send/receive raw data block, a connection resource must be indicated. Note: If an invalid rack or slot number is entered, the communication connection will not be set up WinCC Handbuch

257 08.97 Channels 4.6 SIMATIC TI505 Serial Communication Driver This communication driver is used for the serial connection to the SIMATIC TI505 PLC Data Type of Tags This communication driver has a channel unit that makes it possible to operate a COM port for serial connection. The following application is available: Channel Unit SIMATIC TI505 Unit #1 for serial communication by means of either the TBP protocol or the NITP protocol. Note: It is possible to use one channel unit to operate more than one logical connection (by means of different COM ports). You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag Unsigned 8-bit value (supported only by VMS addressing) Signed 8-bit value (supported only by VMS addressing) Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number WinCC Manual 4-45 Siemens Hardware

258 Channels Address of Tags You enter the tag address according to the address structure of SIMATIC TI505. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the desired data type (for example, signed 16-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. 4. In the "Address Type" box, select the location of the tag in the PLC. Depending on the address type that you select, you must supply additional information (for example, in the "Data Element" box for the "V - Variable Memory" address type). 5. If you select the "Read-Only Tag" check box, you can specify that the WinCC system cannot write to the tag. Note: For a description of the address types, consult the technical documentation for SIMATIC TI WinCC Handbuch

259 08.97 Channels SIMATIC TI505 Unit #1 Channel Unit The process driver connection by means of serial connection is possible with the SIMATIC TI505 PLC. In this PLC, the serial interface on the CPU module is used. No additional communication module is needed in the WinCC system. Communication can take place by means of one of the standard COM ports available in the system. How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "Communication" tab. 3. In the "Serial Port Name" box, select the communication interface (for example, COM1, COM2, or a configured port) for the serial connection. WinCC Manual 4-47 Siemens Hardware

260 Channels Select the "Detect Automatically" box if the channel unit should detect automatically the data transmission speed and the protocol used by the controller. or In the boxes "Baud Rate" and "Protocol," set the data transmission speed and protocol used. 5. By selecting the "Optimized Requests" check box, you can optimize the data transmission to be able to transmit several tags with one request. 6. If you select the "Deactivate Connection" box, the logical connection is deactivated. For example, this is a good idea during system startup if you want to interrupt a connection temporarily. 4.7 SIMATIC TI505 Ethernet Layer 4 Communication Driver This communication driver is used for the connection to such PLCs as the SIMATIC TI505 by means of the ISO transport protocol. Channel Units This channel DLL has two channel units that make it possible to operate a maximum of two CP 1413 s. The functionality of the channel units is identical. They differ only in their logical device names. You can change the logical device name by means of the system parameters of the channel unit. You can also set the parameters for the ISO transport protocol here. The following applications are possible: Channel Unit TI505 Ethernet (CP ) for the communication modules for SIMATIC Industrial Ethernet (for example, CP 1413). Channel Unit TI505 Ethernet (CP ) for the communication modules for SIMATIC Industrial Ethernet (for example, CP 1413) Data Type of Tags You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag Unsigned 8-bit value (supported only by VMS addressing) Signed 8-bit value (supported only by VMS addressing) Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value 32-bit IEEE 754 floating-point number 4-48 WinCC Handbuch

261 08.97 Channels Address of Tags You enter the tag address according to the address structure of SIMATIC TI505. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the desired data type (for example, signed 16-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. 4. Select the TI505 tab. 5. In the "Address Type" box, select the location of the tag in the PLC. Depending on the address type that you select, you must supply additional information (for example, in the "Data Element" box for the "V - Variable Memory" address type). 6. If you select the "Read-Only Tag" check box, you can specify that the WinCC system cannot write to the tag. WinCC Manual 4-49 Siemens Hardware

262 Channels Note: For a description of the address types, consult the technical documentation for SIMATIC TI505. Access to the memory locations of a PLC can often take place only by byte or word. If binary or 8-Bit tags are used, the Address Properties dialog will contain an additional tab, through which individual bits, in the PLC s memory locations, can be changed. For that reason, every write instruction reads the addressed memory location from the PLC and changes the corresponding bits/bytes. Afterwards, the data is written back into the PLC. Note: Changes to the read data, made by the PLC, will be overwritten during the write back. Depending on the tag type, access, to the memory locations of a PLC, is carried out either by bit or by byte Setting the by Bit Access: 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Binary Tag data type. 3. Click on the Select button to open the Address Properties dialog WinCC Handbuch

263 08.97 Channels 4. Via the checkbox, the By Bit accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed from the list box. Note: In the S5 PLC, markers, inputs, and outputs can be addressed by byte, and data blocks (DB, DX) can be addressed by word. Setting the by Byte Access 1. Right mouse button click on the desired tag to open its pop-up menu, and select Properties. 2. Open the General Information tab and select the Unsigned 8-Bit Value or Signed 8-Bit Value data type. 3. Click on the Select button to open the Address Properties dialog. 4. Via the checkbox, the By Byte accessing method can be selected. 5. Select the addressing method of the PLC memory locations from the list box. 6. Select the number of the bit to be changed from the list box. WinCC Manual 4-51 Siemens Hardware

264 Channels System Parameters for the TI505 Ethernet (CP 1413-x) Channel Unit The process driver connection by means of Industrial Ethernet is possible with the SIMATIC TI505 PLCs. These PLCs use the CP 1434 TF communication module. Communication takes place by means of the ISO transport protocol. The WinCC system uses the CP 1413 communication module. Because communication takes place by means of the ISO transport protocol, it is not necessary to configure the logical connection in the local database. How to Configure the System Parameters: 1. Select the channel unit and use the pop-up menu to open the "System Parameters" dialog box. 2. Select the "Device Names" tab. 3. Select the device name displayed in bold type and click in the name box to change the device name. Note: The device name is specified when the hardware driver is installed. Only if you assigned a different name then (which, however, is not a good idea) do you have to change the device name here also WinCC Handbuch

265 08.97 Channels 4. Select the "Transport Parameters" tab. 5. Set the value in the "PDU Size" box to the value that was also configured on the CP 1434 TF. 6. In the "Setup Attempts" box, specify how often an attempt should be made to set up a connection. 7. In the "Duration of Send Repetitions" area, select "Infinite." 8. In the "Acknowledgment Time" box, enter the value 30 so that you are informed after no more than 30 seconds by means of the tag status that the remote PLC did not answer within this time (for example, PLC is in the STOP mode). WinCC Manual 4-53 Siemens Hardware

266 Channels TI505 Ethernet (CP 1413-x) Channel Unit For a logical connection, WinCC sets up one connection each for reading (READ) and writing (WRITE) in the transport layer. The logical connection is not designated as set up until both of these connections have been established. How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "Connection" tab. 3. In the "Ethernet Address Controller" box, enter the station address of the SIMATIC TI505 on the Industrial Ethernet bus. 4. Specify the parameters for the READ function in the WinCC system. They depend on the request used in the SIMATIC TI505. WinCC Side FETCH Active (Request "READ Active") FETCH Passive (Request "WRITE Passive") SIMATIC TI505 Side READ Passive (Request "READ Passive") WRITE Active (Request "WRITE Active") 4-54 WinCC Handbuch

267 08.97 Channels 5. In the "Own TSAP-ID" box, enter the value that was configured for the CP 1434 TF as "TSAP" under the heading of "Remote Parameters." 6. In the "External TSAP-ID" box, enter the value that was configured for the CP 1434 TF as "TSAP" under the heading of "Local Parameters." 7. Enter the appropriate parameters for "Own TSAP-ID" and "External TSAP-ID" for the WRITE function. WinCC Side Request "WRITE Active" SIMATIC TI505 Side Request "WRITE Passive" 4.8 Windows DDE Communication Driver This communication driver is used for connecting to applications by means of the DDE interface (Dynamic Data Exchange). Channel Unit This communication channel has a channel unit that makes it possible to operate the interface. The following application is available: Channel unit DDE for communication by means of the DDE interface of Windows Data Type of Tags You define the tags necessary for a logical connection. WinCC enables you to access the following data types: Binary tag Unsigned 8-bit value Signed 8-bit value Unsigned 16-bit value Signed 16-bit value Unsigned 32-bit value Signed 32-bit value Text tag 8-bit character set WinCC Manual 4-55 Siemens Hardware

268 Channels Address of Tags You enter the tag address according to the address structure of the DDE server application. How to Enter the Tag Address: 1. Select the tag and use the pop-up menu to open the "Properties" dialog box. 2. In the "General Information" tab, select the desired data type (for example, signed 8-bit value). 3. Click on the "Select" button. The "Address Properties" dialog window opens. 4. In the "Tag Name" box, enter the name of the tag in the DDE server (for example, with Excel for the cell in the third line and the second column "l3c2"). Letters of the alphabet must always be written in lower case. 5. In the "Data Type" box, also specify the data type in the DDE server (for example, "WORD" for an unsigned 16-bit value). Note: Although the data are generally transmitted in text format ("CF_TEXT") over the DDE channel, it is absolutely necessary to specify matching data types for the DDE client and the DDE server WinCC Handbuch

269 08.97 Channels DDE Channel Unit Data access by means of a DDE channel is possible both locally and remotely. The DDE client sets up a DDE connection to the DDE server and then transmits in Windows standardized DDE commands to access the tags. No additional communication module is needed in the WinCC system. Communication takes place locally by means of a DDE channel in the operating system. If the DDE server is remote, the network function of Windows is employed. In this case, the program "Netdde.exe" and the network adapter of Windows are used. How to Configure the Communication Parameters: 1. Select the connection and use the pop-up menu to open the "Properties" dialog box. 2. Select the "DDE Connection" tab. 3. If the DDE server is not located on your computer, use the "Computer Name" box to enter the name of the computer from which the data are to be requested by means of the DDE connection. 4. In the "Application" box, enter the name of the server application (in our example, "excel" for the table calculation program Excel). WinCC Manual 4-57 Siemens Hardware

270 Channels In the "Topic" box, specify the file being processed by the application (for example, "product.xls table"). 6. In the "Procedure for Reading Tags" area, specify the criteria for reading the tags. The following assignment applies: WinCC Side Always fetch Fetch only after change Fetch automatically upon change DDE Function REQUEST/POKE COLD ADVISE/POKE HOT ADVISE/POKE WARM 7. In the "Response Time" box, you should enter a value greater than In the "Connection Setup Attempts" area, you should select the "Infinite" box. In this case, an attempt will be made to set up the connection until the connection setup is successful. Notes: The DDE server application and the file specified in the "Topic" box must be started in the ONLINE mode during setup of the DDE connection. If you have questions concerning the function of the Windows DDE interface and assigning parameters to the DDE interface for external applications, consult the appropriate documentation from Microsoft and from the manufacturer of the external application WinCC Handbuch

271 08.97 Channels Index C Channel DLL 3-2 Channel unit 3-2 Channel unit 505 Ethernet (CP 1413-x) 4-54 Channel unit S5 Application (CP1413-x) 4-25 Channel unit S5-Transport (CP1413-x) 4-21 Communication parameters for SIMATIC 505 Ethernet Layer Communication parameters for SIMATIC 505 Serial 4-47 Communication parameters for SIMATIC S5 Ethernet Layer Communication parameters for SIMATIC S5 Ethernet TF 4-25 Communication parameters for SIMATIC S7 Protocol Suite 4-39; 4-40; 4-41 Connection 3-2 D Data types SIMATIC 505 Ethernet Layer Data types SIMATIC 505 Serial 4-45 Data types SIMATIC S5 Ethernet Layer Data types SIMATIC S5 Ethernet TF 4-22 Data types SIMATIC S5 Programmers Port AS Data types SIMATIC S5 Serial 3964R 4-3 Data types SIMATIC S7 Protocol Suite 4-29 Data types Windows DDE 4-55 DDE channel unit 4-57 G Group tag 3-3 L Logical connection 3-2 S S5-AS511 channel unit 4-14 S5-RK512 (3964R) 4-7 S7 Funktionsbaustein 4-37 S7 MPI channel unit 4-39 SFB 37 AR_SEND 4-37 SIMATIC 505 Unit # SIMATIC S5 Programmers Port AS511 channel DLL 4-8 SIMATIC S5 Programmers Port AS511 communication parameters 4-14 SIMATIC S5 Serial 3964R communication parameters 4-7 SINEC H1 channel unit 4-41 SINEC L2 channel unit 4-40 Status of driver connections 3-2 System parameters for SIMATIC 505 Ethernet Layer System parameters for SIMATIC S5 Ethernet Layer System parameters for SIMATIC S5 Ethernet TF 4-24 T Tag 3-3 Tag address SIMATIC 505 Ethernet Layer Tag address SIMATIC 505 Serial 4-46 Tag address SIMATIC S5 Ethernet Layer Tag address SIMATIC S5 Ethernet TF 4-23 Tag address SIMATIC S5 Programmers Port AS Tag address SIMATIC S5 Serial 3964R 4-3 Tag address SIMATIC S7 Protocol Suite 4-30 Tag address Windows DDE 4-56 Tag group 3-3 W Windows DDE communication parameters 4-57 WinCC Manual Siemens Hardware Index-1

272 Channels Index2 WinCC Handbuch

273 WinCC User Administrator Manual Edition August 1997 Siemens Hardware

274 WinCC, SIMATIC, SINEC, STEP are Siemens registered trademarks. All other product and system names in this manual are (registered) trademarks of their respective owners and must be treated accordingly. (The reproduction, transmission or use of this document or ist contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.) (We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed.) Siemens AG All rights reserved Technical data subject to change Printed in the Federal Republic of Germany Siemens Aktiengesellschaft

275 Table of Contents / User Administrator 1 General Information Functional Principle of the User Administrator User Administrator Configuration System User Administrator Run-Time System Tasks of the User Administrator Structure of the User Administrator Configuration System The Project Window Navigation Window Table Window The Menu Bar "File" Menu User Menu Adding a Group Adding a User Copying a User Deleting a User/Group Changing the Password Changing the Name Table Menu Adding a New Authorization Level Deleting an Authorization Level "Chip Card" Menu "View" Menu Turning the Toolbar On and Off Turning the Status Bar On and Off Help Menu Index Using Help About WinCC User Administrator The Toolbar The Status Bar Procedures Structure of a Password Manager Selecting an Authorization Level Operating in the Run-Time System WinCC Options for the User Administrator Menu Addition Chip Card Chip Card Reader in Run Time Appendix User Administrator WinCC Manual Siemens Hardware i

276 User Administrator ii WinCC Manual

277 08.97 User Administrator Preface Purpose of the Manual This manual is a reference which introduces you to the functions and operation of each software component. You can find the information you need by means of the table of contents or the index. Of course, this information is also available in the on-line help as context-sensitive Help or by means of the Help contents. General Overview and Configuration Example In the Getting Started Manual, you can find a general overview of WinCC and a configuration example. The example enables you to carry out the essential functions of the individual components in a practical application. Additional Assistance If you have technical questions, please contact the Siemens representative in your area. You can find the addresses in such sources as the Siemens Worldwide appendix of the S7-300 Programmable Controller System, Hardware and Installation Manual; catalogs; and in CompuServe (go autforum)... In addition, our hotline is available at the following telephone number: +49 (911) (Fax 7001). You can find more information in the Internet under the following address: Information about SIMATIC products Up to date information about SIMATIC products can be obtained: * from the Internet under * via fax# In addition, the SIMATIC Customer Support provides current information and downloads that can be beneficial for the utilization of SIMATIC products: * from the Internet under * via the SIMATIC Customer Support Mailbox under phone# +49 (911) * To address the mailbox, use a modem with up to V.34 (28.8 kbaud), which parameters must be set as follows: 8, N, 1, ANSI, or dial up through ISDN (x.75, 64 kbit). The SIMATIC Customer Support can be reached by phone under the number +49 (911) and by fax under the number +49 (911) Inquiries can also be made via Internet mail or mail addressed to the above mailbox. WinCC Manual Siemens Hardware iii

278 User Administrator iv WinCC Manual

279 08.97 User Administrator 1 General Information The "User Administrator" editor is a module that assigns user authorization for the run-time modules of the individual editors. Access authorizations are assigned to a user by means of a list and then loaded in the data base. The corresponding access authorizations are enabled in the individual editors. If a colleague logs on to the run-time module, his assigned access authorization is checked and the project areas with the corresponding access levels are enabled. In the "User Administrator" chapter, you learn about the following: Functionality Structure Available authorization levels How to work with the "User Administrator." WinCC Manual 1-1 Siemens Hardware

280 User Administrator WinCC Manual

281 08.97 User Administrator 2 Functional Principle of the User Administrator The "User Administrator" module assigns and controls user access authorizations. When you are assigned the appropriate authorizations, you receive access to WinCC. Authorizations are assigned to each individual user. Up to 999 different access levels can be assigned. User authorizations can be assigned during run time. When a user logs on to the system, the User Administrator checks to see if the user is registered. This can apply to the configuration system as well as the run-time system of all editors. If you are not registered, you have no rights in the system. In extreme cases, this means that you cannot call up or view any data. If a registered user calls up a function, the User Administrator checks if there is an authorization for this access. If you do not have the access authorization, the User Administrator refuses you access to the selected function. The User Administrator is divided into two components for assigning user authorizations. 2.1 User Administrator Configuration System The User Administrator configuration system (User Administrator CS) manages the users. When new users are entered, the system assigns passwords and records the user authorizations in a table. 2.2 User Administrator Run-Time System The main task of the User Administrator run -time system (User Administrator RT) is to monitor the system logons and access authorizations. This applies on the configuration level as well as the run -time level. 2.3 Tasks of the User Administrator The User Administrator carries out the following tasks: Loading and changing users and groups Assigning and managing access authorizations Structure of an access protection Selective protection from unauthorized access to individual system functions Logging off a user after an operating break (you can set the length of the break) WinCC Manual 2-1 Siemens Hardware

282 User Administrator WinCC Manual

283 08.97 User Administrator 3 Structure of the User Administrator Configuration System The "User Administrator" is similar in structure to the other editors in WinCC. The interface contains the following features: Menu Bar Toolbar A project window divided into two sections (three sections in the last release) Status Bar 3.1 The Project Window The project window consists of the following two windows: Navigation window on the left Table window on the right Navigation Window The navigation window contains a tree structure view of the groups that are set up and the corresponding registered users. Your user name is entered in the box with the gray background at the top of the navigation window. Click the right mouse button on the selected user or selected user group to open the pop-up menu for the user. WinCC Manual 3-1 Siemens Hardware

284 User Administrator Table Window The top of the table window contains the login name or the user identifier. The settings displayed in the table window all relate to this particular user. Directly beneath the name, there is a box for setting an automatic logout. This way, you can block unlimited access to the system by external users after you have made a change. If you enter "0," the access is not closed until after the system is turned off. The bottom area of the table window displays a list of the authorizations that are set up. The numbers are identified as authorization levels. In the "Enable" column, use the left mouse button to assign authorization levels to the selected user. In the presetting, the "User Administration" item is always selected for the administrator group. You cannot delete the authorization level "1." This level of authorization is preset for the users in the "Administrator" group. You must assign authorization levels individually. Multiple authorizations can only be transferred optionally according to the group assignment when you create a new user in a group. There can be 999 levels in the table. 3.2 The Menu Bar All of the commands available in the User Administrator configuration system are divided logically into groups and assigned to different menus in the Menu Bar. To execute a command, open the appropriate menu, click on the command and, if necessary, set the required parameters "File" Menu Exit Use this menu item to finish your entry in the editor and exit it. The changes are transferred directly when the editor is used User Menu The "User" menu contains all of the menu items needed to set up new users. You can group users that have or will receive the same authorizations. Those users will then receive the same authorizations as the group. This way, you can avoid having to assign the same authorizations within a group manually. 3-2 WinCC Manual

285 08.97 User Administrator Adding a Group Use the "Add Group" item in the "User" menu to add a new group. There are no subgroups. How to Add a New Group: 1. In the "User" menu or the corresponding pop-up menu, select the "Add Group" menu item. A new group is set up in the project navigation window. A text window with a cursor appears next to the group icon. 2. Enter the name of the new group. 3. Assign the desired authorization levels. Note: A group name can only be assigned once. WinCC Manual 3-3 Siemens Hardware

286 User Administrator Adding a User Use the "Add User " menu item in the "User" menu to add a new user to the selected group. Enter the required parameters in the "Establish New User" dialog window. Area Description Login Identification of the user with a length of 4 to 24 characters. It appears as a user name in the tree in the navigation window. Password User password. It must be between 6 and 24 characters long. Retype Password Copy group settings also Additional entry of the password to check it. Reenter your password. If this check box is selected, all of the group settings are copied. Note: A user name can only be assigned once. 3-4 WinCC Manual

287 08.97 User Administrator Copying a User Use the "Copy User" menu item in the "User" menu to copy the selected user with all of its settings. Enter the required parameters in the "Copy User " dialog box. Area Description Login Identification of the user with a length of 4 to 24 characters. It appears as a user name in the tree in the navigation window. Password User password. It must be between 6 and 24 characters long. Retype Password Additional entry of the password to check it. Reenter your password. Note: A login user name can only be assigned once. It appears in the tree view in the project navigation window Deleting a User/Group The selected object is removed. WinCC Manual 3-5 Siemens Hardware

288 User Administrator Changing the Password Use the "Change Password" menu item in the "User" menu to assign a new password to the selected user. Enter the required parameters in the "Copy User " dialog box. Area Description Login Identification of the user with a length of 4 to 24 characters. It appears as a user name in the tree in the navigation window. Password Old user password. It must be between 6 and 24 characters long. New Password New user password. It must be between 6 and 24 characters long. Retype Password Additional entry of the password to check it. Reenter your password Changing the Name You can change the name of a user or a group. Changing a name does not affect the password of this user Table Menu Use the "Table" menu to change or expand the user rights in the table window. Only the user administration function cannot be deleted. It is permanently set for members of the "Administrator" group. 3-6 WinCC Manual

289 08.97 User Administrator Adding a New Authorization Level Use the "Insert New Authorization Level " command to add a new line to the table in the table window Deleting an Authorization Level Use the "Delete Authorization Level" command to delete a line from the table in the table window. The selected line is deleted. Note: If you delete an authorization level, it is deleted for all of the entered users "Chip Card" Menu You can activate this menu only when the "Chip Card" option is installed. You can get additional information from the manual for this option package. 3.3 "View" Menu Use the "View" menu to change the display of the bars Turning the Toolbar On and Off Use the "Toolbar" command to turn the Toolbar on or off depending on your need Turning the Status Bar On and Off Use the "Status Bar" command to turn the Status Bar on or off depending on your need. The Status Bar is displayed in the main window of the User Administration configuration system on the bottom edge of the window. WinCC Manual 3-7 Siemens Hardware

290 User Administrator Help Menu The "Help" menu contains functions that provide you direct access to on-line help. In the User Administrator configuration system, you can access on-line help with the "F1" function key. Help text for the selected object appears Index Use the "Index" command to call up the User Administrator on -line help index. You can learn more about this procedure from the Windows 95 description Using Help Use the "Using Help" command to get information about how to manage on-line help About WinCC User Administrator Use the "About WinCC User Administrator" command to receive more information about the selected editor and its platform. The current version number and the copyright information is displayed in the information window. You can also see a reference to the operating system platform for which this program was developed. 3-8 WinCC Manual

291 08.97 User Administrator 3.5 The Toolbar The Toolbar looks like the following: These icons allow you to execute actions more rapidly. You do not have to make several selections through the menus until you reach the required function. "User" "Add User" "Group" "Add Group" "User" "Copy User" "User" "Delete" "User" "Change Password" "Context-Sensitive Help" 3.6 The Status Bar The left side of the Status Bar contains general program information. You can find out about the meaning of the boxes on the right side of the bar from the "Control Center" section of the user manual. 3.7 Procedures The User Administrator allocates rights to the users in two steps. You can assign each of your colleagues with a password to exactly one group. It is logical to assign users to a group based on the authorizations that the users receive. WinCC Manual 3-9 Siemens Hardware

292 User Administrator Structure of a Password Manager How to Construct Your Password Manager: 1. Create the necessary groups. 2. Select the appropriate authorization level for each group. 3. Create the users. Assign the appropriate login names and passwords. Copy the group properties. 4. Select the specific rights for each user. Also, select the time frame in which the system is unprotected following the most recent input. The data are applied without storing them Selecting an Authorization Level If you are working in another editor and call up the User Administrator to assign authorization levels, the following dialog box appears: It contains the authorization levels in the authorization numbering sequence. If you select an authorization level here, only users that have the appropriate authorization level can access this dialog from the run -time module. 1. Use the "Authorization Level" button to open the dialog box. 2. Select the desired authorization level. 3. Exit the dialog box WinCC Manual

293 08.97 User Administrator Operating in the Run-Time System Start the run -time system. Use the key combination set in the Control Center to open the password dialog box. Enter your login name and your password. The system check the rights assigned to you with the authorization levels in the editors and the attached components. It allows you access if you have the matching authorization. You can find out how to set key combinations in the "Hotkeys Tab" area of the Control Center manual. WinCC Manual 3-11 Siemens Hardware

294 User Administrator WinCC Manual

295 08.97 User Administrator 4 WinCC Options for the User Administrator If WinCC is installed with the "Chip Cards" option, the functionality of the User Administrator is expanded. The "Chip Card Reader" option adds a "Chip Card" item with appropriate functions to the Menu Bar. 4.1 Menu Addition Chip Card The User Administrator provides functions to control a chip card reader/writer. You can write and check chip cards in the configuration system. Note: You can only activate this menu if WinCC was installed with the "Chip Card" option. Writing To a Chip Card When you write to a chip card, all of the data on the card are deleted. The user (login name) and the password are stored on the chip card. Note: You can only activate this menu if WinCC was installed with the "Chip Card" option. WinCC Manual 4-1 Siemens Hardware

WinCC V4. Manual Part 2/3 C79000-G8276-C107-01

WinCC V4. Manual Part 2/3 C79000-G8276-C107-01 WinCC V4 Manual Part 2/3 Edition August 1997 WinCC, SIMATIC, SINEC, STEP are Siemens registered trademarks. All other product and system names in this manual are (registered) trademarks of their respective

More information

Siemens Distributor SIMATIC. Component based Automation Creating PROFInet Components

Siemens Distributor SIMATIC. Component based Automation Creating PROFInet Components s SIMATIC Component based Automation Creating PROFInet Components Manual Preface, Contents Creating PROFInet components with STEP 7 1 SIMATIC Devices as PROFInet components 2 Singleton components 3 Appendix

More information

SINAUT ST7. SINAUT ST7cc Control Center A I. Manual. Introduction to ST7cc. Installation. Preparation. Working with ST7cc Config

SINAUT ST7. SINAUT ST7cc Control Center A I. Manual. Introduction to ST7cc. Installation. Preparation. Working with ST7cc Config Introduction to ST7cc 1 Installation 2 SINAUT ST7 SINAUT ST7cc Control Center Manual Preparation Working with ST7cc Config 3 4 ST7cc Config with EXCEL 5 Valid for ST7cc Server 6 Product Software Version

More information

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode s SIMATIC Process Control PCS 7 V7.0 PCS 7 OS Process Control Operating Instructions Preface, Contents Additional Documentation 1 Functions of the PCS 7 OS in Process Mode 2 PCS 7 OS Process Mode - User

More information

SIMATIC Automation License Manager Manual 02/2008 A5E

SIMATIC Automation License Manager Manual 02/2008 A5E s Contents SIMATIC Automation License Manager Product Overview 1 Installation 2 Working with the Automation License Manager 3 Glossar Index Manual 02/2008 A5E02128430-01 Safety Guidelines This manual contains

More information

Aotewell SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St

Aotewell   SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St SIMATIC S7-PDIAG for S7-300 and S7-400 - Configuring Process Diagnostic Getting Started Edition 01/2003 First Steps with S7-PDIAG and ProAgent The Getting Started for This product is not a stand-alonedescription.

More information

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3 Preface 1 Additional documentation 2 SIMATIC Process Control System PCS 7 Operating Instructions Functions of the PCS 7 OS in process mode 3 PCS 7 OS process mode - user interface 4 System operator inputs

More information

Preface 1. Main Management System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS4000 X-Tools - User Manual Main Management System.

Preface 1. Main Management System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS4000 X-Tools - User Manual Main Management System. 4000 X-Tools - User Manual - 03 - Main Management System Preface 1 Main Management System 2 Contact Information 3 4000 X-Tools User Manual - 03 - Main Management System Release 2011-09 Release 2011-09

More information

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication

SIMATIC HMI. WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started. Welcome 1. Icons 2. Creating a project. Configure communication Welcome 1 Icons 2 SIMATIC HMI WinCC V7.4 SP1 SIMATIC HMI WinCC V7.4 Getting Started Getting Started Creating a project 3 Configure communication 4 Configuring the Process Screens 5 Archiving and displaying

More information

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2. Overview of process control system options 1 OS Project Editor 2 SIMATIC HMI WinCC V7.4 System Manual Horn 3 Time Synchronization 4 Lifebeat Monitoring 5 Picture Tree Manager 6 Graphic Object Update Wizard

More information

NiceForm User Guide. English Edition. Rev Euro Plus d.o.o. & Niceware International LLC All rights reserved.

NiceForm User Guide. English Edition. Rev Euro Plus d.o.o. & Niceware International LLC All rights reserved. www.nicelabel.com, info@nicelabel.com English Edition Rev-0910 2009 Euro Plus d.o.o. & Niceware International LLC All rights reserved. www.nicelabel.com Head Office Euro Plus d.o.o. Ulica Lojzeta Hrovata

More information

SIMATIC. PCS 7/505 OS Setup Guide for V6.1. Preface, Contents. Introduction 1. Install the Software. Update a project from V6.0 to V6.

SIMATIC. PCS 7/505 OS Setup Guide for V6.1. Preface, Contents. Introduction 1. Install the Software. Update a project from V6.0 to V6. s SIMATIC PCS 7/505 OS Setup Guide for V6.1 Manual Preface, Contents Introduction 1 Install the Software 2 Update a project from V6.0 to V6.1 3 Create a New OS Project 4 Deploy the Changes 5 Modify Faceplates

More information

Preface 1. X-Tools Client 2. Contact Information 3. User Manual X-Tools Client. English. Release English. Release / 25

Preface 1. X-Tools Client 2. Contact Information 3. User Manual X-Tools Client. English. Release English. Release / 25 Preface 1 X-Tools Client 2 Contact Information 3 X-Tools User Manual - 02 - X-Tools Client Release 2015-11 Release 2015-11 1 / 25 Safety Guidelines This document contains notices which you should observe

More information

SIMATIC. Process Control System PCS 7 Operator Station. Preface, Contents. The PCS 7 OS 1 Introduction to PCS 7 OS Configuration

SIMATIC. Process Control System PCS 7 Operator Station. Preface, Contents. The PCS 7 OS 1 Introduction to PCS 7 OS Configuration s SIMATIC Process Control System PCS 7 Operator Station Configuration Manual Preface, Contents The PCS 7 OS 1 Introduction to PCS 7 OS Configuration 2 Configuring the PCS 7 OS Data in the SIMATIC Manager

More information

Siemens Parts SIMATIC. Process Control System PCS 7 WinCC Basic Process Control. Important Notes, Contents

Siemens Parts SIMATIC. Process Control System PCS 7 WinCC Basic Process Control. Important Notes, Contents SIMATIC Process Control System PCS 7 WinCC Basic Process Control Manual Important Notes, Contents System Overview 1 Overview of the Editors of the Option 2 Split Screen Wizard 3 The Alarm Logging Wizard

More information

SIMATIC HMI. StoragePlus V1.3 SP1 / PCS 7 V7.1 MDM - Storage Plus Information System. StoragePlus Installation Instructions 1. StoragePlus Readme 2

SIMATIC HMI. StoragePlus V1.3 SP1 / PCS 7 V7.1 MDM - Storage Plus Information System. StoragePlus Installation Instructions 1. StoragePlus Readme 2 StoragePlus Installation Instructions 1 StoragePlus Readme 2 SIMATIC HMI StoragePlus V1.3 SP1 / PCS 7 V7.1 MDM - Storage Plus Information System StoragePlus Administration Console 3 StoragePlus View Editor

More information

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station SIMATIC Process Control System PCS 7 Configuration Manual Preface 1 The PCS 7 Operator Station 2 Introduction to OS configuration 3 Setting languages 4 Configuring OS data in SIMATIC Manager 5 Configuring

More information

SIMATIC HMI. WinCC flexible 2004 Micro. Preface. Introduction to WinCC flexible Micro 1. WinCC flexible Engineering System.

SIMATIC HMI. WinCC flexible 2004 Micro. Preface. Introduction to WinCC flexible Micro 1. WinCC flexible Engineering System. Preface Introduction to WinCC flexible Micro 1 SIMATIC HMI WinCC flexible 2004 Micro User's Manual WinCC flexible Engineering System 2 Working with tags 3 Creating screens 4 Creating an alarm system 5

More information

Computer Basics Written by Brian O'Rooney. Copyright 2000 Nanaimo Literacy Association All rights reserved

Computer Basics Written by Brian O'Rooney. Copyright 2000 Nanaimo Literacy Association All rights reserved Written by Brian O'Rooney Copyright 2000 Nanaimo Literacy Association All rights reserved Windows is a registered trademark of Microsoft Corporation. This product/publication includes images from WordPerfect

More information

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Security information 1. Preface 2. Additional documentation 3 Security information 1 Preface 2 SIMATIC Process Control System PCS 7 Operating Instructions Additional documentation 3 Functions of the PCS 7 OS in process mode 4 PCS 7 OS process mode - user interface

More information

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.

Deckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry. Deckblatt SIMATIC PCS 7 Application description June 2011 Applikationen & Tools Answers for industry. Industry Automation and Drive Technologies Service & Support Portal This article is taken from the

More information

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7 SIMATIC Component Based Automation SIMATIC Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components Configuration Manual Preface Creating PROFINET components in STEP 7 1 SIMATIC

More information

[ ] INFOLOG. Hand-held terminal type PSION. Operating Manual. for SITRANS F US ultrasonic flowmeter type SONOCELL and SONO 3301 *085R9464*

[ ] INFOLOG. Hand-held terminal type PSION. Operating Manual. for SITRANS F US ultrasonic flowmeter type SONOCELL and SONO 3301 *085R9464* s Operating Manual INFOLOG Hand-held terminal type PSION for SITRANS F US ultrasonic flowmeter type SONOCELL and SONO 3301 [ ] SAP No. FDK-521H1200 SFIDK.PS.029.D1.02 *085R9464* 1. Introduction Contents

More information

Preface 1. Master Data System 2. Contact Information 3. User Manual Master Data System. English. Release English

Preface 1. Master Data System 2. Contact Information 3. User Manual Master Data System. English. Release English Preface 1 Master Data System 2 Contact Information 3 X-Tools User Manual - 02 - Master Data System Release 2014-11 Release 2014-11 1 / 21 Safety Guidelines This document contains notices which you should

More information

SIMATIC HMI. Configuring Graphics Displays. Product Brief. Edition 12/01. Table of Contents. Introduction. Commissioning Operating Units

SIMATIC HMI. Configuring Graphics Displays. Product Brief. Edition 12/01. Table of Contents. Introduction. Commissioning Operating Units SIMATIC HMI Configuring Graphics Displays Table of Contents Introduction Commissioning Operating Units Product Brief Basic Steps for a Configuration Extend Configuration with Simple Elements Edition 12/01

More information

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System SIMATIC HMI WinCC V7.0 SP1 SIMATIC HMI WinCC V7.0 SP1 WinCC Alarm Logging 1 Message System in WinCC 2 Principles of the Message System 3 Configuring the Message System 4 Printout of the Online Help 11/2008

More information

Basic Windows 95 Skills

Basic Windows 95 Skills Building Mouse Skills Click press left mouse button once used to select options in menus or to move your cursor Double click press left mouse button twice without moving the mouse pointer used on icons

More information

Preface 1. Main Management System 2. Contact Information 3. User Manual Main Management System. English. Release

Preface 1. Main Management System 2. Contact Information 3. User Manual Main Management System. English. Release Preface 1 Main Management System 2 Contact Information 3 X-Tools User Manual - 03 - Main Management System Release 2015-11 Release 2015-11 1 / 40 Safety Guidelines This document contains notices which

More information

WINDOWS NT BASICS

WINDOWS NT BASICS WINDOWS NT BASICS 9.30.99 Windows NT Basics ABOUT UNIVERSITY TECHNOLOGY TRAINING CENTER The University Technology Training Center (UTTC) provides computer training services with a focus on helping University

More information

PCS 7/APACS+ OS Option Software 8.0 SP1

PCS 7/APACS+ OS Option Software 8.0 SP1 SIMATIC PCS 7/APACS+ OS Option Software 8.0 SP1 Notes on Installation and Usage These notes should be considered more up-to-date than the information in other documents. They contain important information

More information

Preface 1. Storage System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS X-Tools - User Manual Storage System. English.

Preface 1. Storage System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS X-Tools - User Manual Storage System. English. X-Tools - User Manual - 07 - Storage System Preface 1 Storage System 2 Contact Information 3 X-Tools User Manual - 07 - Storage System Release 2012-09 Release 2012-09 1 / 44 X-Tools - User Manual - 07

More information

Sage Getting Started Guide. September 2017

Sage Getting Started Guide. September 2017 Sage 100 2018 Getting Started Guide September 2017 2017 The Sage Group plc or its licensors. All rights reserved. Sage, Sage logos, and Sage product and service names mentioned herein are the trademarks

More information

User s Manual CAP 531*1.5 Configuration and Programming tool

User s Manual CAP 531*1.5 Configuration and Programming tool User s Manual CAP 531*1.5 Configuration and Programming tool This manual belongs to: Contents Chapter Page About this manual 1 Introduction 3 Technical descriptions 81 References 177 Customer feedback

More information

Introduction to Windows

Introduction to Windows Introduction to Windows Naturally, if you have downloaded this document, you will already be to some extent anyway familiar with Windows. If so you can skip the first couple of pages and move on to the

More information

ABBYY FineReader 14. User s Guide ABBYY Production LLC. All rights reserved.

ABBYY FineReader 14. User s Guide ABBYY Production LLC. All rights reserved. ABBYY FineReader 14 User s Guide 2017 ABBYY Production LLC All rights reserved Information in this document is subject to change without notice and does not bear any commitment on the part of ABBYY The

More information

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started. Continuous Function Chart Getting Started SIMATIC Process Control System PCS 7 Continuous Function Chart Getting Started Getting Started Preface 1 Creating a closed loop with a simulated process 2 Testing

More information

NETWORK PRINT MONITOR User Guide

NETWORK PRINT MONITOR User Guide NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We

More information

SIMATIC HMI. WinCC V7.0 SP1 MDM - WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC HMI. WinCC V7.0 SP1 MDM - WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2. Overview of process control system options 1 OS Project Editor 2 SIMATIC HMI WinCC V7.0 SP1 MDM - WinCC/Options for Process Control System Manual Horn 3 Time Synchronization 4 Lifebeat Monitoring 5 Picture

More information

Once you have entered your Google and password, you can click the Sign In button to continue.

Once you have entered your Google  and password, you can click the Sign In button to continue. Slide 1 Welcome to the Creating and Uploading with Google Docs Tutorial. Google Docs allows you to create documents, spreadsheets, presentations, draw pictures, create forms, and much more directly within

More information

P r o f e s s i o n a l 4. 6 G e t t i n g S t a r t e d G u i d e

P r o f e s s i o n a l 4. 6 G e t t i n g S t a r t e d G u i d e Milestone XProtect P r o f e s s i o n a l 4. 6 G e t t i n g S t a r t e d G u i d e Dear Milestone Customer, With the purchase of Milestone XProtect Professional you have chosen a very powerful and intelligent

More information

Programming Interface Description of the Functions

Programming Interface Description of the Functions SIMATIC NET Programming Interface DP-Base Master Class 2 for CP 5613/CP 5614 Preface, Contents of the Functions of the DP Master Class 2 1 Manual C79000-G8976-C165-01 Release 07/2001 Classification of

More information

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release X-Tools - User Manual - 04 - Device Management System Preface 1 Device Management System 2 Contact Information 3 X-Tools User Manual - 04 - Device Management System Release 2016-10 Release 2016-10 1 /

More information

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3 SIMATIC Component based Automation - WinLC PN Addendum to WinAC Basis V3.0 Manual Foreword 1 Introduction to CBA and WinAC PN 2 Routing with WinLC PN 3 Installing WinLC PN 4 Commissioning WinLC PN 5 Notes

More information

Horizon Launcher Configuration Guide

Horizon Launcher Configuration Guide Horizon Launcher Configuration Guide Windows NT and Windows 2000 are registered trademarks of Microsoft Corporation. All other product or company names are trademarks or registered trademarks of their

More information

CFC. Special functions from SIMATIC S7 CFC V7.0 SP1 onwards

CFC. Special functions from SIMATIC S7 CFC V7.0 SP1 onwards CFC Function Function expansions from SIMATIC S7 CFC V7.1 onwards Forcing of values of an interconnected input: by means of the "Force functionality", interconnected block inputs can be forced to use the

More information

Production feedback via WinCC Data Transfer with XML file

Production feedback via WinCC Data Transfer with XML file Application Example 09/2016 Production feedback via WinCC Data Transfer with XML file WinCC/IndustrialDataBridge V7.4, SIMATIC WinCC V7 https://support.industry.siemens.com/cs/ww/en/view/109483465 Warranty

More information

KMnet Viewer. User Guide

KMnet Viewer. User Guide KMnet Viewer User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We cannot be

More information

Quick Start Guide. ARIS Architect. Version 9.7

Quick Start Guide. ARIS Architect. Version 9.7 ARIS Architect Version 9.7 October 2014 This document applies to ARIS Version 9.7 and to all subsequent releases. Specifications contained herein are subject to change and these changes will be reported

More information

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release X-Tools - User Manual - 04 - Device Management System Preface 1 Device Management System 2 Contact Information 3 X-Tools User Manual - 04 - Device Management System Release 2015-11 Release 2015-11 1 /

More information

SAS/ACCESS Interface to R/3

SAS/ACCESS Interface to R/3 9.1 SAS/ACCESS Interface to R/3 User s Guide The correct bibliographic citation for this manual is as follows: SAS Institute Inc. 2004. SAS/ACCESS 9.1 Interface to R/3: User s Guide. Cary, NC: SAS Institute

More information

DataMaster for Windows

DataMaster for Windows DataMaster for Windows Version 3.0 April 2004 Mid America Computer Corp. 111 Admiral Drive Blair, NE 68008-0700 (402) 426-6222 Copyright 2003-2004 Mid America Computer Corp. All rights reserved. Table

More information

Quick Start Guide. ARIS Architect. Version 9.8 Service Release 2

Quick Start Guide. ARIS Architect. Version 9.8 Service Release 2 ARIS Architect Version 9.8 Service Release 2 October 2015 This document applies to ARIS Version 9.8 and to all subsequent releases. Specifications contained herein are subject to change and these changes

More information

FR-V/FR FAMILY SOFTUNE C/C++ CHECKER MANUAL for V5

FR-V/FR FAMILY SOFTUNE C/C++ CHECKER MANUAL for V5 FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM81-00310-4E FR-V/FR FAMILY SOFTUNE C/C++ CHECKER MANUAL for V5 FR-V/FR FAMILY SOFTUNE C/C++ CHECKER MANUAL for V5 FUJITSU LIMITED PREFACE Objectives Thank you

More information

Installing a Custom AutoCAD Toolbar (CUI interface)

Installing a Custom AutoCAD Toolbar (CUI interface) Installing a Custom AutoCAD Toolbar (CUI interface) AxciScape produces AutoCAD script files which must be Run within AutoCAD. You can do this by typing SCRIPT into the command line and then select the

More information

HikCentral Control Client. User Manual

HikCentral Control Client. User Manual HikCentral Control Client User Manual Legal Information User Manual 2018 Hangzhou Hikvision Digital Technology Co., Ltd. About this Manual This Manual is subject to domestic and international copyright

More information

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation.

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation. - Installation Notes 1 - Release Notes 2 SIMATIC HMI - Documentation 3 WinCC V7.4 SP1 System Manual 05/2017 A5E40959835-AA Legal information Warning notice system This manual contains notices you have

More information

MockupScreens - User Guide

MockupScreens - User Guide MockupScreens - User Guide Contents 1. Overview...4 2. Getting Started...5 Installing the software... 5 Registering... 9 3. Understanding the Interface...11 Menu Bar... 11 Tool bar... 14 Elements... 14

More information

Introduction. Installation. DOConCD. Operation. Installation and Operation. Attachment. User Instructions. Edition

Introduction. Installation. DOConCD. Operation. Installation and Operation. Attachment. User Instructions. Edition Introduction 1 Installation 2 DOConCD Operation 3 Installation and Operation User Instructions Attachment A Edition 03.2004 This document was generated with WinWord V 8.0 and Designer V 7.0 and the DokuTool

More information

Preface Master Data System Contact Information SIPLUS CMS

Preface Master Data System Contact Information SIPLUS CMS Preface 1 Master Data System 2 Contact Information 3 X-Tools User Manual - 02 - Master Data System Release 2012-09 Release 2012-09 1 / 17 Safety Guidelines This document contains notices which you should

More information

Sage Getting Started Guide

Sage Getting Started Guide Sage 100 2016 Getting Started Guide This is a publication of Sage Software, Inc. Version 2016 Copyright 2015 Sage Software, Inc. All rights reserved. Sage, the Sage logos, and the Sage product and service

More information

SIMATIC. PDM V5.2 The Process Device Manager. Preface, Contents. Product Introduction 1. Starting SIMATIC PDM 2 Configuring Networks and Devices 3

SIMATIC. PDM V5.2 The Process Device Manager. Preface, Contents. Product Introduction 1. Starting SIMATIC PDM 2 Configuring Networks and Devices 3 SIMATIC PDM V5.2 Manual Preface, Contents Product Introduction 1 Starting SIMATIC PDM 2 Configuring Networks and Devices 3 SIMATIC PDM Integrated 4 Working with SIMATIC PDM 5 Loading of Data Between Various

More information

Included with the system is a high quality speech synthesizer, which is installed automatically during the SymWord setup procedure.

Included with the system is a high quality speech synthesizer, which is installed automatically during the SymWord setup procedure. Introduction to SymWord SymWord is a simple to use, talking, symbol-word processor. It has the basic functionality of a word processor. SymWord can also be configured to produce speech and/or display text

More information

User's Guide. Voice Messaging and Fax Software. FaxTalk Communicator SETM

User's Guide. Voice Messaging and Fax Software. FaxTalk Communicator SETM User's Guide Voice Messaging and Fax Software FaxTalk Communicator SETM FaxTalk Communicator SE for Windows Version 4.7 Telephone Consumer Protection Act of 1991 "It shall be unlawful for any person within

More information

How to Use Serif WebPlus 10

How to Use Serif WebPlus 10 How to Use Serif WebPlus 10 Getting started 1. Open Serif WebPlus and select Start New Site from the Startup Screen 2. WebPlus will start a blank website for you. Take a few moments to familiarise yourself

More information

Standard Windows Keyboard Layout & Keyboard Shortcuts

Standard Windows Keyboard Layout & Keyboard Shortcuts Standard Windows Keyboard Layout & Keyboard Shortcuts Desktop keyboard Laptop keyboard Explanation of the Keys on a Windows QWERTY Keyboard Q W E R T Y "The name "QWERTY" for our computer keyboard comes

More information

GUARD1 PLUS Documentation. Version TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks

GUARD1 PLUS Documentation. Version TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks GUARD1 PLUS Documentation Version 3.02 2000-2005 TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks i of TimeKeeping Systems, Inc. Table of Contents Welcome to Guard1 Plus...

More information

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation Preface 1 Additional documentation 2 SIMATIC Process Control System PCS 7 Function Manual Overview of the Web Option for OS 3 Configuration with Web Option for OS 4 Hardware and Software Requirements 5

More information

SIMATIC. Process Control System PCS 7 OS Web Option (V7.1) Preface 1. Additional documentation 2. Overview of PCS 7 OS Web Option

SIMATIC. Process Control System PCS 7 OS Web Option (V7.1) Preface 1. Additional documentation 2. Overview of PCS 7 OS Web Option SIMATIC SIMATIC Process Control System PCS 7 Function Manual Preface 1 Additional documentation 2 Overview of PCS 7 OS Web Option 3 Configuration with PCS 7 OS Web option 4 Hardware and Software Requirements

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface Overview 1 SIMATIC Process Control System PCS 7 Advanced Process Functions Operator Manual Operating Manual Material management 2 Material lot management 3 Storage location management 4 Parameter

More information

1 Software Redundancy

1 Software Redundancy 1 Software Redundancy Within WinCC, the software redundancy feature makes it possible to monitor critical sections of a plant by using a redundant connection to several PLCs. WinCC (Tag Management) Tag

More information

Contents. Why You Should Read This Manual...ix. 1. Introduction... 1

Contents. Why You Should Read This Manual...ix. 1. Introduction... 1 Contents Why You Should Read This Manual...ix 1. Introduction... 1 Understanding Security... 2 Group and User Accounts... 2 Application Features... 3 Security Areas... 3 Using Windows Security... 7 Synchronizing

More information

KYOCERA Net Viewer 5.3 User Guide

KYOCERA Net Viewer 5.3 User Guide KYOCERA Net Viewer. User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Using the Computer & Managing Files Part 2

Using the Computer & Managing Files Part 2 Using the Computer & Managing Files Part 2 Using the Computer & Managing Files...65 Example 1 File compression, or zipping...66 Exercise 1 Download and install software...66 Exercise 2 Understand file

More information

DISCLAIMER Whilst every effort has been made

DISCLAIMER Whilst every effort has been made PUBLISHED BY Gallagher Group Limited Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand www.gallagherams.com Copyright Gallagher Group Limited 2011. All rights reserved. Patents Pending. MyScale Pro

More information

Policy Commander Console Guide - Published February, 2012

Policy Commander Console Guide - Published February, 2012 Policy Commander Console Guide - Published February, 2012 This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes

More information

Acknowledgement of WinCC Messages with forced comments WinCC V7 https://support.industry.siemens.com/cs/ww/en/view/52329908 Siemens Industry Online Support Warranty and liability Warranty and liability

More information

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2 SIMATIC Process control system PCS 7 Configuration Manual Valid for PCS 7 as of V9.0 SP1 Security information 1 Preface 2 The PCS 7 Operator Station 3 Introduction to OS configuration 4 Setting the languages

More information

Océ Engineering Exec. Advanced Import and Index

Océ Engineering Exec. Advanced Import and Index Océ Engineering Exec Advanced Import and Index Océ-Technologies B.V. Copyright 2004, Océ-Technologies B.V. Venlo, The Netherlands All rights reserved. No part of this work may be reproduced, copied, adapted,

More information

OptionPower 3.2. for Office 2007 STARTUP GUIDE. Interactive Audience Response Systems

OptionPower 3.2. for Office 2007 STARTUP GUIDE. Interactive Audience Response Systems OptionPower for Office 2007 3.2 STARTUP GUIDE Interactive Audience Response Systems OptionPower for Office 2007 3.2 STARTUP GUIDE 2008 Option Technologies Interactive This document is the copyrighted and

More information

User Manual Customer Interaction Express 3.3 TaskFlow Editor

User Manual Customer Interaction Express 3.3 TaskFlow Editor User Manual Customer Interaction Express 3.3 TaskFlow Editor Edition: 1.0 07/22/2015 COMPAS ID: 116794 2015 Avaya Inc. All Rights Reserved. Notice While reasonable efforts were made to ensure that the

More information

KYOCERA Net Viewer User Guide

KYOCERA Net Viewer User Guide KYOCERA Net Viewer User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Using Sitecore 5.3.1

Using Sitecore 5.3.1 Using Sitecore 5.3.1 An End-User s Guide to Using and Administrating Sitecore Author: Sitecore Corporation Date: December 12, 2007 Release: Rev. 1.0 Language: English Sitecore is a registered trademark.

More information

Basic Concepts. Launching MultiAd Creator. To Create an Alias. file://c:\documents and Settings\Gary Horrie\Local Settings\Temp\~hh81F9.

Basic Concepts. Launching MultiAd Creator. To Create an Alias. file://c:\documents and Settings\Gary Horrie\Local Settings\Temp\~hh81F9. Page 1 of 71 This section describes several common tasks that you'll need to know in order to use Creator successfully. Examples include launching Creator and opening, saving and closing Creator documents.

More information

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1 Preface Connecting SCALANCE S615 to the WAN 1 SIMATIC NET VPN tunnel between SCALANCE S615 and 2 SINEMA RC Server Industrial Ethernet Security Getting Started 07/2017 C79000-G8976-C390-02 Legal information

More information

Teamcenter 11.1 Systems Engineering and Requirements Management

Teamcenter 11.1 Systems Engineering and Requirements Management SIEMENS Teamcenter 11.1 Systems Engineering and Requirements Management Systems Architect/ Requirements Management Project Administrator's Manual REQ00002 U REQ00002 U Project Administrator's Manual 3

More information

1 Ctrl + X Cut the selected item. 2 Ctrl + C (or Ctrl + Insert) Copy the selected item. 3 Ctrl + V (or Shift + Insert) Paste the selected item

1 Ctrl + X Cut the selected item. 2 Ctrl + C (or Ctrl + Insert) Copy the selected item. 3 Ctrl + V (or Shift + Insert) Paste the selected item Tips and Tricks Recorder Actions Library XPath Syntax Hotkeys Windows Hotkeys General Keyboard Shortcuts Windows Explorer Shortcuts Command Prompt Shortcuts Dialog Box Keyboard Shortcuts Excel Hotkeys

More information

Device Programming using TRWinProg

Device Programming using TRWinProg Device Programming using TRWinProg Software No.: _490-00416 _490-00416_WIN7 _Program Summary _Safety instructions _System requirements _Program installation _Connecting devices to the PC _Program start

More information

SIMATIC HMI. ProTool Configuring Windows-based Systems. Contents. Preface. Introduction. Installing and configuring ProTool.

SIMATIC HMI. ProTool Configuring Windows-based Systems. Contents. Preface. Introduction. Installing and configuring ProTool. Contents Preface 1 SIMATIC HMI ProTool Configuring Windows-based Systems Introduction Installing and configuring ProTool Creating projects Configuration techniques 2 3 4 5 User s Manual Testing projects

More information

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3. User management and electronic signatures 1 Hardware and Software Requirements 2 SIMATIC Scope of delivery 3 Installation 4 SIMATIC Logon 5 Configuration Manual 12/2015 A5E34528136-AA Legal information

More information

Microsoft PowerPoint 2013 Beginning

Microsoft PowerPoint 2013 Beginning Microsoft PowerPoint 2013 Beginning PowerPoint Presentations on the Web... 2 Starting PowerPoint... 2 Opening a Presentation... 2 File Tab... 3 Quick Access Toolbar... 3 The Ribbon... 4 Keyboard Shortcuts...

More information

MindView Online - Quick Start Guide

MindView Online - Quick Start Guide MindView Online - Quick Start Guide Overview MindView Online is an online concept mapping program that allows users to organize their thoughts visually to create, share, and export mind maps to Microsoft

More information

Siemens Drives & PLCs

Siemens Drives & PLCs SIMATIC HMI Configuring Text-based Displays Table of Contents Introduction Commissioning Operating Units Product Brief Basic Steps for a Configuration Extend Configuration with Simple Elements Edition

More information

Contents. User's Guide

Contents. User's Guide Contents i User's Guide ii Contents No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without prior written permission from

More information

ARIS Architect QUICK START GUIDE. Version Service Release 7

ARIS Architect QUICK START GUIDE. Version Service Release 7 ARIS Architect QUICK START GUIDE Version 9.8 - Service Release 7 December 2016 This document applies to ARIS Version 9.8 and to all subsequent releases. Specifications contained herein are subject to change

More information

Print Station. Point-and-Click Printing WHITE PAPER

Print Station. Point-and-Click Printing WHITE PAPER Print Station Point-and-Click Printing WHITE PAPER Contents Overview 3 Printing with Print Station 4 Easy-to-use Browser Interface 4 Familiar Folder Navigation 5 Search Functionality 6 Informative Display

More information

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3 Preface Security information 1 SIMATIC Process Control System PCS 7 Advanced Process Functions Operator Manual Operating Manual Overview 2 Material management 3 Material lot management 4 Storage location

More information

Software Introduction

Software Introduction Software Introduction B Software Introduction Design Era Universal V11.21 November 2011 Table of Contents Welcome to Stitch/Design Era Universal software.... 1 Basic User Interface... 1 Application button

More information

Full User Manual and Quick Start Guide

Full User Manual and Quick Start Guide Full User Manual and Quick Start Guide 2 W hile every precaution has been taken in the preparation of this manual, we assume no responsibility for errors or omissions. Neither, is any liability assumed

More information

Electrical System Functional Definition

Electrical System Functional Definition Electrical System Functional Definition Preface What's New? Getting Started Basic Tasks Advanced Tasks Workbench Description Customizing Glossary Index Dassault Systèmes 1994-2000. All rights reserved.

More information