[ ] INFOLOG. Hand-held terminal type PSION. Operating Manual. for SITRANS F US ultrasonic flowmeter type SONOCELL and SONO 3301 *085R9464*
|
|
- Moris Lambert
- 5 years ago
- Views:
Transcription
1 s Operating Manual INFOLOG Hand-held terminal type PSION for SITRANS F US ultrasonic flowmeter type SONOCELL and SONO 3301 [ ] SAP No. FDK-521H1200 SFIDK.PS.029.D1.02 *085R9464*
2 1. Introduction Contents 1. Introduction System requirements Quick start Collect data View data Transfer data to PC Set-up mode Service menu Error status Customer number Account day SITRANS F US SONOFLO type SONOCELL and SONO 3301 time SITRANS F US SONOFLO type SONOCELL and SONO 3301 date Installing the data transfer software on your PC Running the data transfer software program Storage of data Update software Uninstalling Trouble shooting No communication between PC and INFOLOG Program re-load/re-start Data.csv file in Microsoft Excel Read-out examples of SITRANS F US SONOFLO type SONOCELL and SONO SITRANS F US SONOFLO type SONOCELL and SONO 3301 actual data (from Excel) Introduction Navigate arrows Collect data Transfer data Viev available menu See data Set-up mode The Siemens data transfer system consists of 6 parts. The INFOLOG unit, an infrared optical head, solid state disk (flash) containing the software program for INFOLOG, a CD with software program for data transfer from INFOLOG to PC, a 9 pol. 0-modem cable and a copy of the Operating Manual. The hand-held terminal type PSION (Workabout MX) ("INFOLOG"), is used to read-out the actual values, account values or monthly data of Siemens flow measuring units of the SITRANS F US ultrasonic flowmeter types SONOCELL and SONO 3301 ("SITRANS F US 105") and transfer data into e.g. an Excel spread sheet for further data processing. The read-out can be made by use of infrared optical head (order No. FDK-087H0108). In addition to read-outs, the INFOLOG can be used for changing customer numbers, SONOCELL and SONO 3301 account date and read-out/reset of error codes. 1.1 System requirements Windows 98, Windows 2000 and Windows XP 5 MB after installation As a standard the SONOCELL Data Transfer Programme (SDTP) will be distributed on CD with install shield based installation package and the software for INFOLOG will be distributed on static flash. 2 SFIDK.PS.029.D1.02
3 2. Quick start 2. Quick start When you receive a complete set from Siemens the unit is almost ready for use. In order to protect batteries from leaking into the INFOLOG at storage, the 2 batteries and the lithium cell are added separately. 1. Open the slot by pressing the tab 2. Insert the 2 x 1.5 V penlight batteries in the INFOLOG and insert the back-up lithium cell 3. Insert the flash solid state disk in "drive A" The software program on the flash now has to be copied to the INFOLOG. 1. Switch on the INFOLOG by pressing 2. SHIFT + DEL + On/Esc The program will start installing the software on your terminal. When asked: YES 3. "Stop link?" Press and wait for the program to continue 4. "Create M\OVD" Press YES and wait for the program to start 5. The program is now installed on your INFOLOG and the display shows To get a general understanding of the INFOLOG functionality review the INFOLOG menu structure at Appendix A. 2.1 Collect data F1 Connect the optical eye to SONOCELL or SONO Pressing F1 starts data collection - and a bar code indicates the status. A small beep indicates the INFOLOG has received data successfully. Costumer number and total accumulated volume are then displayed - indicating that INFOLOG has stored data successfully. The INFOLOG can store up to 1500 readings. View data (F2) may be slow due to the high data capacity when approx. 400 readings have been made. Note Users in F1 mode are only allowed to read accumulated values as preset under the menu F4. As default the INFOLOG is set to data collect and actual data. 2.2 View data F2 is used to view data. F2 By using the following arrows it is possible to scroll through the collected data. As the values are relatively small in the display, it is possible to enlarge the digits by pressing ENTER whenever the digits are highlighted. SFIDK.PS.029.D1.02 3
4 2. Quick start 2.3 Transfer data to PC F3 To export the data from the INFOLOG to the PC the software programme (SDTP.exe) should be installed. Install the software program as described in chapter 4. The cable supplied with INFOLOG is a 0-modem cable. Start the program and ensure the INFOLOG is in "F3" mode in order to establish communication to the PC. Activate "Download data from INFOLOG" and data will now be transferred. (If this was the first time to use the program you may have to activate the same function again). A red wire between the INFOLOG and the PC icon indicates that connection is established. Data will normally be stored on your PC under folder: (Installation directory) doc\data.csv. Note To save disk space on INFOLOG, users should delete the old data file after transferring it to PC. A new file will be created for new data. Before starting the deleted operation, users are asked to enter the INFOLOG password. This will limit the use of this operation to permitted users. 4 SFIDK.PS.029.D1.02
5 2. Quick start 2.4 Set-up mode F4 This mode is password protected. F4 gives you the following possibilities: ApplicationSelect This menu offers the following choices: DataCollect Mode - the INFOLOG is used only as a datalogger, without any possibilities for set-up of data. ServiceMode - opens for change/views of: 1. Read-out of actual values, account values, monthly values (previous 24 months). 2. Error code, customer number, account date and SONOCELL and SONO 3301 (SITRANS F US 105) date and time adjust. See chapter 3 for further information regarding choices in service mode. DataSelect This menu offers the following choices: Actual data: This data includes: Customer number, serial no., total volume, hour counter, peak flow in the actual month, SONOCELL and SONO date and time, error code. Date/time of INFOLOG. Account A data: The same types of data as above but this data represents the accumulated values at preset read off date. Communication The menu contains 3 choices: Data reading port: Is set by default "A". Communication rate: Is set by default to 300. SONOCELL and SONO 3301 supports only 300 baud whenever communication is via the optical eye. Data transfer to PC port: Must be set to "A" (If used with dokingsstation the set port to "C"). ChangePassword This provides dialog to change the password of INFOLOG. Time date adjust This provides the functionality to adjust date and time of the INFOLOG. SW Version Displays the software version in the INFOLOG. SFIDK.PS.029.D1.02 5
6 3. Service menu 3. Service Menu To set the INFOLOG into the service mode follow the following steps: (refer to appendix A). 1. Press F4. 2. A password dialog will be displayed. Enter INFOLOG password then press Enter. 3. Press Menu and a menu-bar will be displayed as shown in "Set-up" paragraph. 4. Highlight the "Application Set-up" and press Enter. 5. In "Application Select" dialog select "Server mode" by using the arrow keys and press Enter. Now the INFOLOG is enabled to be set in service mode. 6. Press F1 to enter the service mode (Shown in the next 2 figures) In service mode the INFOLOG is able to read different type of data. Use arrows required data type: Actual readings Account A Month-1, months-2, months-3..months-24. Select Menu to enter into service menu Use the arrows to scroll up/down in menu. to select In general readings and changing settings will take a 30 seconds. In the bottom of the display a status line indicates the actual commands when using the service menu. Use arrows and "del" and keypads to enter new settings. Note To erase digits under the item write, move the curser using the arrows so that the curser is flashing behind the digit. Use del to change or erase digits. 3.1 Error status Select menu Enter READ RESET ESC reads the actual error code resets all error codes escape from error status F: represents no failure. The failure code is represented with F3 and F5 depending on failure type. F3: Internal fault F5: Volume flow exceeds the preset Qs value. 6 SFIDK.PS.029.D1.02
7 3. Service menu 3.2 Customer number Select menu Enter READ WRITE ESC reads the customer number type new customer number escape from customer number dialog SONOCELL and SONO 3301: Password is default The customer number as default is as v, ww, y, ssss, where "v" represents the software version number, "ww" represents the week of production, "y" represents the production year and "ssss" represents the 4 digits in the serial number. Example: Customer number: = software version 25 = production week 3 = year = represents serial number Maximum customer number length: 8 digits Whenever changing the SITRANS F US 105 customer number you are prompted to insert the password. 3.3 Account day Select menu Enter READ WRITE ESC reads the account date enter new day/months (alteration of account date requires SONOCELL and SONO 3301 passwords) escape from account day dialog 3.4 SITRANS F US 105 time Select menu/sitrans F US 105 time Enter READ reads the actual time in hours and minutes WRITE type new hour: minutes (hh:nn) ESC escape from SITRANS F US 105 time dialog Note SONOCELL and SONO 3301 uses the actual time and date to store any failures. It is recommended that the real time clock is set correctly. If INFOLOG is set correctly with hh::nn--dd/mm/yyyy this will appear in the display. (See chapter 2.4). 3.5 SITRANS F US 105 date Select menu/sitrans F US 105 date Enter READ reads the actual day/month/year WRITE type new date (day/month/year) (dd.mm.yy) ESC escape from SONOCELL and SONO 3301 date Note SONOCELL and SONO 3301 uses the actual time/date to store any failures. It is recommended the real time clock is set correctly. If INFOLOG is set correctly with time/minutes/day/months/year this will appear in the display. (See chapter 2.4). SFIDK.PS.029.D1.02 7
8 4. Installing the data transfer software on your PC (SDTP) 4. Installing the data transfer software on your PC 4.1 Running the data transfer software program Insert CD in your computer and this will auto-start the installation program Follow the instruction on your screen This will install "SDTP" program on your computer and all necessary subdirectories. It will also create 2 short-cuts: one on your program files and one on the desktop. Double click this short-cut to run the SONOCELL data transfer program. The created directories are: "Data" directory: Holds the data transfer from INFOLOG "Doc" directory: License.txt and infolist.txt files "HTSW" directory: Includes the upgrade of INFOLOG software The easiest way to start the program is to double click the short-cut made by the installation program on your desktop or on the program menu (start\programs\infolog\sdtp). A connection indicator will appear on the right corner on your screen (Tool menu) trying to connect. Connection is made when this indicator shows a sine wave. To exit the program press quit. The sine wave will be a horizontal line indicating that the program is ready to reconnect when it is reactivated. Right click the icon indicator to disconnect, reconnect or terminate the link between the hand terminal and PC. Press the "Download Data from INFOLOG" button to copy data from INFOLOG to PC. If the connection is not already established, it will be established and the data file will be transferred. In case of a connection error the function will terminate and the button should be repressed when the connection is established. If the file exists you can choose to rename the file, overwrite the old copy or cancel the operation. 4.2 Storage of data Data will normally be stored under the (installation)folder: doc\data.csv. 4.3 Update software It is possible to download the latest new SONOCELL data transfer program via our homepage First you have downloaded the SONOCELL data transfer program on your PC. It is possible then to update/install the INFOLOG software program. Install the software on your INFOLOG from the SONOCELL data transfer program: Press "download program for INFOLOG". The program will give you the following message to guide you through the software update: 8 SFIDK.PS.029.D1.02
9 4. Installing the data transfer software on your PC 4.3 Update software (continued) Step 1 of 4 Step 2 of 4 1. Update software: Be sure that INFOLOG is in F3 mode and continue the installation by pressning on Ok. 2. First time installation (no software program in the INFOLOG (Virgin unit)). This means that F3 is not active, and the INFOLOG has to be set-up into a "Link" mode where it is possible to communicate with the PC. Set-up of INFOLOG in "Link" mode: 1. Push On/Esc to start PSION device 2. Press Menu and select command processor and press Enter 3. M>\ appears in the display 4. Press Menu and use to step to the menu "Special" 5. Select remote link followed by Enter 6. By use of select "On" and "port A" followed by Enter 7. INFOLOG is now ready to receive the software program from the PC. Step 3 of 4 Select download software for INFOLOG Step 4 of 4 SFIDK.PS.029.D1.02 9
10 4. Installing the data transfer software on your PC 4.3 Update software (continued) Following the instruction above complete the update of the INFOLOG software and the following picture will be present: 4.4 Uninstalling Uninstalling the program Closing the program and related programs From control panel\removesw\uninstall the program Answer yes to remove the unused dll s, and check the box to avoid the same message from re-appearing It may be necessary to manually remove some of the copied files 5. Trouble shooting 5. Trouble shooting 5.1 No communication between PC and INFOLOG Ensure that the data transfer cable is connected between the PC and INFOLOG Ensure that INFOLOG is in F3 mode Ensure that the cable is a 0-modem cable The connection between INFOLOG and PC is indicated by the redline between their icons Set link to the connected port A (in F4 menu) 5.2 Program re-load/ re-start The software in the INFOLOG is suitable to all kind of input. If you need to re-start the program carry out the following to preserve data: Software reset (shift+del+on), this will re-load the program and run the exe file Re-install the program (see chapter 4.3) 5.3 Data.csv file in Microsoft Excel If the format of the data in the Excel sheet is not displayed correctly, try the following in Excel: Mark the first column and press text to columns in data menu Ensure delimited is marked in the convert text to columns wizard step 1 of 3 and press Next Insure "Comma" check box is marked in step 2 and press Next Mark column "General\Total\Volume" and press on Advanced Set decimal separator to "." and thousands separator to "," and press OK Press Finish To align all data to the left do the following: Mark all the data by pressing on the left upper corner Click the mouse right button and chose format cells from pop up menu Chose Alignment in the Text alignment chose left in the horizontal box Note: The data is transferred in ASCII format with "." as decimal separator. 6. Readout examples of SONOCELL and SONO Readout examples of SONOCELL and SONO SONOCELL and SONO 3301 actual data (from Excel) Cust. No. Serial No. Total volume Unit Peak0 Hour counter Note: Data format is the same as above, date/time of SONOCELL and SONO 3301 is the time of the preset account date. Unit INFOCAL date INFOCAL time ERROR_ Status IN- FOLOG_ Date IN- FOLOG_ Time MUSG h :14 F: :21 10 SFIDK.PS.029.D1.02
11 Appendix A: INFOLOG Menu structure SFIDK.PS.029.D
12 We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are always welcomed. Technical data subject to change without prior notice. The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright Siemens AG All Rights Reserved Siemens Flow Instruments A/S Nordborgvej 81 DK-6430 Nordborg Order no.: FDK-521H Printed in: Denmark
User Manual. Thermo Scientific Orion
User Manual Thermo Scientific Orion Orion Star Com Software Program 68X637901 Revision A April 2013 Contents Chapter 1... 4 Introduction... 4 Star Com Functions... 5 Chapter 2... 6 Software Installation
More informationNavigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17
User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3
More informationI.A.M. National Pension Fund Remittance Report Software
I.A.M. National Pension Fund Remittance Report Software The USER S GUIDE INTRODUCTION The I.A.M. National Pension Fund Remittance Report Software version 2.0 (IAMNPF RR Software) is a program created to
More informationWinCC V4. Manual Part 1/3 C79000-G8276-C Edition August Siemens Hardware
WinCC V4 Manual Part 1/3 Edition August 1997 Siemens Hardware WinCC, SIMATIC, SINEC, STEP are Siemens registered trademarks. All other product and system names in this manual are (registered) trademarks
More informationManual SmartGraph for Humlog 10
Manual SmartGraph for Humlog 10 State: 10.12.2001 Version: V1.0 1 1 INTRODUCTION TO SMARTGRAPH... 4 1.1 Manage, Configure... 4 1.2 The Programme Interface... 4 1.2.1 Graphs... 5 1.2.2 Table... 6 1.2.3
More informationWindows Me Navigating
LAB PROCEDURE 11 Windows Me Navigating OBJECTIVES 1. Explore the Start menu. 2. Start an application. 3. Multi-task between applications. 4. Moving folders and files around. 5. Use Control Panel settings.
More informationTach Facts V3.0 Software
Tach Facts V3.0 Software Download runs from your Auto Meter Playback Tach with Tach-Facts Software. Instr. No. 2650-978 Tach Facts provides complete race analysis on your personal computer. Introduction
More informationPowerView for the EnergyPro
Data Analysis Software User's Guide PowerView User's Guide Copyright 2005 CANDURA INSTRUMENTS. All Rights Reserved. The information in this document is subject to change without notice. CANDURA INSTRUMENTS
More informationKV-SS090. Operating Instructions. Instant Scanning Software. Model No.
Operating Instructions Instant Scanning Software Model No. KV-SS090 Thank you for purchasing this Panasonic product. Please read this manual carefully before using this product and save this manual for
More informationINTERFACE & SOFTWARE GUIDE
TM INTERFACE & SOFTWARE GUIDE Wireless Remote Display USB Converter Battery Sensor Setup DataLogger Software r e m o t e i n t e r f a c e escape enter status w w w. s k y s t r e a m e n e r g y. c o
More informationManual SITRANS F US SONOFLO. Ultrasonic flowmeter Sensor type SONOCELL. Order no.: FDK:521H1172 *085R9463* SFIDK.PS.029.B2.
s Manual SITRANS F US SONOFLO Ultrasonic flowmeter Sensor type SONOCELL [ ] Order no.: FDK:521H1172 SFIDK.PS.029.B2.02 - A5E00253430 *085R9463* Contents 1. Introduction... 3 1.1 Precision measuring system...
More informationFor ClassPad 300. ClassPad Manager. (ProgramLink) Limited Version. User s Guide. RJA
For ClassPad 300 E ClassPad Manager (ProgramLink) Limited Version User s Guide RJA510188-4 http://world.casio.com/edu_e/ Note Display examples shown in this User s Guide are intended for illustrative purposes
More informationDISCLAIMER Whilst every effort has been made
PUBLISHED BY Gallagher Group Limited Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand www.gallagherams.com Copyright Gallagher Group Limited 2011. All rights reserved. Patents Pending. MyScale Pro
More informationAxxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit
Axxis Biometrics LLC BioAxxis L113 Fingerprint Door Lock Programming Kit Revision 0.14 Dec 2005 Table of Contents 1. Introduction... 2 Product Overview... 2 Main Features... 2 Packing Lists... 3 2. Operation
More informationRemoteOne / ReportOne User Manual
RemoteOne / ReportOne User Manual SW Version 0.9.12.101 / Manual Release 2012-03-26 RemoteOne / ReportOne User Manual Contents Contents 1 Introduction... 5 2 Start / exit the program... 7 2.1 Start and
More informationUser Guide 701P Wide Format Solution Wide Format Scan Service
User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.
More informationExhibitor Software User s Manual. Exhibitor Software V
Exhibitor Software User s Manual Exhibitor Software V1.0.1 090908 1 Contents 1. Exhibitor Software 2. Installation 3. Using Exhibitor Program 3.1 Starting the Program 3.2 Logging in to the Program 3.3
More informationSpectrometer Visible Light Spectrometer V4.4
Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8
More informationPower Vision 1.5 (Cod )
ELECTRICAL NETWORK ANALYSIS SOFTWARE Power Vision 1.5 (Cod. 775 353) USER S MANUAL (Cod. M 981 358 / 02 D) 2002 - CIRCUTOR, S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION...4 2.- INTRODUCTION TO POWER
More informationTable of Contents. Part I Introduction. Part II FSM Ribbon. Part III FSM Context Menu. Part IV Trial Balance. Part V Building a report
Contents I Table of Contents Part I Introduction 1 1 Welcome... 2 2 Benefits... of using 3 3 System... Requirements 4 4 Uninstalling... 4 Part II FSM Ribbon 5 Part III FSM Context Menu 5 Part IV Trial
More informationINSTALLING THE PS3 XBOX READY SOFTWARE:
INSTALLING THE PS3 XBOX READY SOFTWARE: 1. Insert the Installation CD to CD-ROM drive and execute Ready_Setup.exe NOTE: If it is the first time for the target USB disk using under this software, the software
More informationSC-01 Data Logger Management Program Operator s Manual
SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by
More informationDriveWizard Plus Instruction Manual
DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5
More informationIBM NetBAY Virtual Console Software. Installer and User Guide
IBM NetBAY Virtual Console Software Installer and User Guide INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the
More informationWireless transfer of screening data from ALGO 3i Screener to PC
Wireless transfer of screening data from ALGO 3i Screener to PC This technical notice provides information on transmitting screening results from your ALGO 3i Newborn Hearing Screener to a personal computer
More informationFiery Network Controller for DocuColor 5065 SERVER & CONTROLLER SOLUTIONS. Utilities
Fiery Network Controller for DocuColor 5065 SERVER & CONTROLLER SOLUTIONS Utilities 2005 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices for this product.
More informationUSB Instruments EasyLogger for PS40M10 "Swordfish" Help
USB Instruments EasyLogger for PS40M10 "Swordfish" Help I EasyLogger for PS40M10 Help Table of Contents Part I Introduction 3 1 Welcome to... EasyLogger for PS40M10 3 2 EasyLogger... Features 4 Part II
More informationAKCess Pro Server Access Control User Manual
www.akcp.com AKCess Pro Server Access Control User Manual Help Version updated till version 118 Copyright 2012, AKCess Pro Co., Ltd.. 1) Introduction A) What is the AKCess Pro Server / Access Control?
More informationUPGRADE INSTRUCTIONS
Version 2.48 or 2.49 & Version 3.48 or 3.49 UPGRADE INSTRUCTIONS System Upgrade Requirements NOTE: Non I-Button: V-Sperm Gold version 3.49 must be installed with SQA-V Gold version 2.49. I-Button: V-Sperm
More informationDT800 Lane Timer Manual
DT800 Lane Timer Manual Features: 1) 8000 Memories 2) Built-in PRINTER 3) Up to10 Lane Buttons 4) PC Upload Function 5) 12/ 24Hr User-selectable Clock 6) 4-Digit Bib Number 7) 4-Digit Place Counter 8)
More informationGX-2009 Data Logger Management Program Operator s Manual
GX-2009 Data Logger Management Program Operator s Manual Part Number: 71-0163RK Revision: P1 Released: 4/30/09 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by
More informationIT Essentials v6.0 Windows 10 Software Labs
IT Essentials v6.0 Windows 10 Software Labs 5.2.1.7 Install Windows 10... 1 5.2.1.10 Check for Updates in Windows 10... 10 5.2.4.7 Create a Partition in Windows 10... 16 6.1.1.5 Task Manager in Windows
More informationGX-2003 Data Logging Software Operator s Manual
GX-2003 Data Logging Software Operator s Manual Part Number: 71-0096RK Revision: P2 Released: May 28, 2004 RKI Instruments, Inc. 1855 Whipple Rd. Hayward, CA 94544 (510) 441-5656 Warranty RKI Instruments,
More information10ZiG Technology. Thin Desktop Quick Start Guide
10ZiG Technology Thin Desktop Quick Start Guide 2010 05 20 Introduction This document is intended as a quick start guide for installing Thin Desktop. After reading this document, you will know how to:
More informationFor additional information, please consult the Read-Me and Help documentation or contact Electro-Voice or Dynacord technical support.
Quick Start Guide Hello, and welcome to IRIS-Net software. We want you to get the most from your IRIS-Net projects and encourage you to explore the additional Read-Me and Help documentation provided with
More informationCentral Management Software. Cam Viewer 3 Lite. User Manual
Central Management Software Cam Viewer 3 Lite User Manual Version 1.0.0 Table of Contents 1. System Requirement...4 2. Software Installation...5 3. Configuration Wizard...9 3.1 Channel...10 3.1.1 Adding
More informationWelcome to noiselab Express 1.0
Welcome to noiselab Express 1.0 Basic Operation Download and install the program. The program automatically unzips and installs. If you don t have a license code, you can run the program in demo mode for
More informationW-E
Signage Suite V2.20 User Guide 605220-02-01-W-E-051613-02 Trademarks Windows XP, Windows Vista, Windows 7, and Microsoft are registered trademarks of Microsoft Corporation. All other trademarks are the
More informationWindows NT Server Printer Driver Upgrade Instructions
Windows NT Server Printer Driver Upgrade Instructions The steps detailed below describe the most reliable method to upgrade printer driver versions after v1.6.0227a on a Windows NT 4.0 Server that is shared
More informationLegal Notes. Regarding Trademarks KYOCERA MITA Corporation
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
More informationUser Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2
User Manual MPPTracker Management Software for Solar Charge Controller Version: 1.2 Table of Contents 1. MPPTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. MPPTracker Install and Uninstall...
More informationPC Software R&S FS300-K1
Copyright 0 Copyright Copyright Licence Agreement Rohde & Schwarz grants you the right to install the R&S FS300-K1 software package on one or more PCs of your choice. The licence included in the software
More informationPreface Master Data System Contact Information SIPLUS CMS
Preface 1 Master Data System 2 Contact Information 3 X-Tools User Manual - 02 - Master Data System Release 2012-09 Release 2012-09 1 / 17 Safety Guidelines This document contains notices which you should
More informationUSER MANUAL. > analyze. reduce. recover
USER MANUAL > analyze > reduce > recover Table of Contents COPY AUDIT... 1 OVERVIEW... 1 IMPORTANT NOTES FOR PRINT AUDIT 4 CUSTOMERS... 1 COMMUNICATOR TECHNICAL NOTES... 2 COPY AUDIT SOFTWARE... 2 INSTALLING
More informationUser Manual PDUTracker
User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software
More informationHow do I apply the patch files?
How do I apply the patch files? 1. Once the patch file has been saved to your hard disk, use Windows Explorer (Start > Programs > [Accessories > ] Windows Explorer) to browse to the directory where the
More informationPreface 1. Storage System 2. Contact Information 3 SIPLUS CMS. SIPLUS CMS X-Tools - User Manual Storage System. English.
X-Tools - User Manual - 07 - Storage System Preface 1 Storage System 2 Contact Information 3 X-Tools User Manual - 07 - Storage System Release 2012-09 Release 2012-09 1 / 44 X-Tools - User Manual - 07
More informationVCOM. User Manual. User Manual for VCOM Serial Device Driver. (November 2007)
VCOM User Manual User Manual for VCOM Serial Device Driver (November 2007) Table of Contents 1) INTRODUCTION... 3 1.1) System Requirements... 3 1.2) Software Installation... 3 1.3) System Startup... 5
More informationMicrosoft Windows Software Manual for FITstep Pro Version 3
Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund
More informationTable of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4
Table of Contents 1. Intended Use.. 3 2. Overview.. 3 2.1 Materials Required. 3 2.2 System Requirements. 3 2.3 User Mode 4 3. Installation Instructions.. 5 3.1 Installing the On Call Diabetes Management
More informationWVL2 Wireless Vehicle Link 2 Installation and Setup Manual
WVL2 Wireless Vehicle Link 2 Installation and Setup Manual Chapter 1: Introducing the Wireless Vehicle Link 2...1 WVL2 Components...2 Component Checklist...3 Product Specifications...4 System Requirements...5
More informationJANOME ELECTRO PRESS. Operation Manual. <PC Operation>
JANOME ELECTRO PRESS JP-104 JP-204 JP-504 JP-1004 JP-1504 JP-3004 JP-5004 JPH-104 JPH-204 JPH-504 JPH-1004 JPH-1504 JPH-3004 JPH-5004 JPU-104 JPU-204 JPU-504 JPU-1004 JPU-1504 JPU-3004 JPU-5004 JPU-8004
More informationNEXTGEN PROGRAMMING SOFTWARE QUICK START GUIDE Copyright Intermatic 2004
NEXTGEN PROGRAMMING SOFTWARE QUICK START GUIDE Copyright Intermatic 2004 RECOMMENDED SYSTEM REQUIREMENTS Processor: 500-MHz Intel Pentium-class processor (Minimum: 90- MHz) Memory: 128MB RAM (Minimum:
More informationDigivu Quick Start Guide. Digivu User Instructions
Digivu Quick Start Guide Digivu User Instructions Page - 2 Digivu User Instructions Page - 3 Table of contents Quick Start Guide 2 Digivu Functions 6 Connecting to a Vehicle Unit 6 Digivu Internal Memory
More informationQUICK START. DevCom2000 User Manual
QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed
More informationLED STUDIO USER MANUAL
BLAIR COMPANIES LED STUDIO USER MANUAL Part # 33-19-14 5107 Kissell Avenue Altoona PA 16601 814-949-8287 blaircompanies.com TABLE OF CONTENTS Chapter 1 Introduction... 1 Chapter 2 Install and Uninstall...
More informationDL160 Datalogger Software Guide
DL160 Datalogger Software Guide The Datalogger USB software is a program for collecting data from the DATA LOGGER when it is connected to a PC or Laptop computer. The data may be displayed graphically
More informationMULTITERM hand-held terminal
Operator s guide to MULTITERM hand-held terminal 28 5511-495 GB/01.03/Rev. E1 Kamstrup A/S Industrivej 28, 8660 Skanderborg TEL: +45 89 93 10 00, FAX: +45 89 93 10 01 E-MAIL: energi@kamstrup.dk WEB: www.kamstrup.com
More informationELECTRONICS. Printed in Korea Code No.: GH A English. 06/2001. Rev.1.0. World Wide Web
The Best Global Communication!... By SAMSUNG * Some of the contents in this manual may differ from your phone, depending on the software installed or your service provider. SGH-Q100 Samsung GPRS Wizard/
More informationComgraph32. Data Retrieval and Analysis for COMBILOG. Version Page 1. Comgraph32. data retrieval and analysis for Combilog version 3
data retrieval and analysis for Combilog version 3 Page 1 3 09.00 2 04.00 Ra 1 01.99 Ra Issue Date Name Feingerätebau K.Fischer GmbH Venusberger Straße 24 D-09430 Drebach Germany Phone +49 (0) 37341 /
More informationPIVOT CMS CLIENT SOFTWARE USER MANUAL
PIVOT CMS CLIENT SOFTWARE USER MANUAL 1 CMS USER GUIDE 1.1 PC REQUIREMENT Recommended PC Requirement OS CPU VGA RAM HDD Graphics Card OS CPU VGA RAM HDD Windows Vista, 7 or higher Intel Core2Quad Q9400
More informationMicrosoft Windows Software Manual for FITstep Stream Version 3
Thank you for purchasing this product from Gopher. If you are not satisfied with any Gopher purchase for any reason at any time, contact us and we will replace the product, credit your account, or refund
More informationMoCo SMS Suite User s Manual
MoCo SMS Suite User s Manual - 1 - Chapter 1: Setting & Starting Up MoCo... 5 1.1 Hardware Setup... 5 1.1.1 USB GSM modem... 5 1.1.2 USB GSM Modem Driver Installation for Win2000/Win2003... 6 1.1.3 USB
More informationVAPOR PRO COMMUNICATIONS
ARIZONA INSTRUMENT LLC VAPOR PRO COMMUNICATIONS OPERATION MANUAL Version 1.0.3 September 2010 Arizona Instrument LLC 3375 N Delaware Street Chandler, AZ 85225 (800) 528-7411 (602) 470-1414 Fax (480) 804-0656
More information& Technical Specifications
User Manual & Technical Specifications User manual Contents Pidion BM-170 Technical specifications... 2 Micro Rolltalk basic package... 3 Micro Rolltalk functions and buttons... 3 Preparing Micro Rolltalk...
More informationMicroTally/WinTally Manual. Introduction
MicroTally/WinTally Manual Introduction Congratulations! You are in possession of one of the finest electronic tally boards made. The MicroTally is a hand held electronic tally counter. It is designed
More informationEFI Fiery Utilities Technical Reference. Part Number: , Rev. 1.0
EFI Fiery Utilities Technical Reference Part Number: 59308805, Rev. 1.0 15 March 2008 CONTENTS 3 CONTENTS INTRODUCTION 5 Terminology and conventions 6 About this document 7 About Help 7 Preparing for installation
More informationGUARD1 PLUS Documentation. Version TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks
GUARD1 PLUS Documentation Version 3.02 2000-2005 TimeKeeping Systems, Inc. GUARD1 PLUS and THE PIPE are registered trademarks i of TimeKeeping Systems, Inc. Table of Contents Welcome to Guard1 Plus...
More informationTechnical Bulletin DS2
Product: DS-Matrix Software TB 221 Date: July 25 th, 2012 Subject: How to Upgrade DS-Matrix Software This document describes the procedure for upgrading the DS-Matrix software. If you are upgrading from
More informationPortable Gas Detector RX-8000 Data Logger Management Program SW-RX-8000(EX) Operating Manual
PT0E-1250 Portable Gas Detector RX-8000 Data Logger Management Program SW-RX-8000(EX) Operating Manual 1 Preface 1-1. Purpose and features of this program 1 Preface The operation procedures and precautions
More informationInstruction Manual. HH610-SW Application Software for Portable & Bench Meters
Instruction Manual HH610-SW Application Software for Portable & Bench Meters Dear Customer, Thank you for choosing an Omega product. Please read this instruction manual carefully before using the software.
More informationTransport Gateway Installation / Registration / Configuration
CHAPTER 2 Transport Gateway Installation / Registration / Configuration This chapter covers the following areas: Transport Gateway requirements. Security Considerations When Using a Transport Gateway.
More informationGalaxy ACCeSS Lite Downloader
Galaxy ACCeSS Lite Downloader Installation and Operating Instructions Honeywell Security Table of contents Introduction...3 Note for Galaxy 3 series panels V5.0x...3 Installation...4 Set-up...4 Running
More informationTTWin 4 Quick Start Guide
Host connectivity for Windows TTWin 4 Quick Start Guide TTWin 4 is the latest evolution of Turbosoft s premier Terminal Emulation package - a fast, accurate, reliable and powerful connectivity tool for
More informationUser Manual MPPTracker
User Manual MPPTracker Management Software for Solar Charge Controller Version: 1.0 Table of Contents 1. MPPTracker Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. MPPTracker Install and Uninstall...
More informationIMPORTANT. Registration Settings: SERIAL NUMBER: COMPUTER ID: REGISTRATION NUMBER:
IMPORTANT Registration Settings: SERIAL NUMBER: COMPUTER ID: REGISTRATION NUMBER: Once you have your TALITY software functioning properly copy your phone system settings onto this page and save it for
More informationCncGcoder Models HD & HDx Manual
CncGcoder Models HD & HDx Manual Table of Contents WELCOME... 3 IN THE BOX... 4 Optional Accessories...4 HANDHELD OVERVIEW... 5 Overview...5 Charging the Battery...6 Turning On and Off...6 Plugging in
More informationHow to Update NN3D to v2.07 (Combo Update) MFDBB
How to Update NN3D to v2.07 (Combo Update) MFDBB 1. NN3D v2.07 Update Introduction MFDBB The combo update for the MFDBB requires a USB Jump Drive (USB flash memory stick). Additionally, a USB KEYBOARD
More informationFor ClassPad 300 PLUS. ClassPad Manager. Version 2.2 (PROGRAM-LINK TM ) User s Guide.
For ClassPad 300 PLUS E ClassPad Manager Version 2.2 (PROGRAM-LINK TM ) User s Guide RJA510188-4 http://world.casio.com/edu/ http://classpad.net/ Note Display examples shown in this User s Guide are intended
More informationumapps Using umapps 6/14/2017 Brought to you by: umtech & The Center for Teaching & Learning
umapps Using umapps Center for Teaching and Learning (CTL) 100 Administration Bldg., Memphis, TN 38152 Phone: 901.678.8888 Email: itstrainers@memphis.edu Center for Teaching and Learning Website 6/14/2017
More informationLorex Client 7.0 & Lorex Message Master
Lorex Client 7.0 & Lorex Message Master Software Manual English Version 1.0 MODELS: L19WD Series www.lorexcctv.com Includes L19WD800 & L19WD1600 Copyright 2008 Lorex Technology Inc. Table of Contents Table
More informationCLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1
CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9
More informationTable of Contents.
Table of Contents 1. Items Included with the BioAxxis ThumbLock Audit Trail Software: 2 2. IMPORTANT NOTE:... 2 3. Supported Operating Systems:... 3 Section 1 Installing the BioAxxis ThumbLock AT Software...
More information-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13
Thank you for buying Data Analysis Software. In order to use this software correctly and safely and to prevent trouble, please read this manual carefully. Notice 1. No part of this manual can be reproduced
More informationZP Recorder INSTRUCTION MANUAL. Force Data Analyzer. For Force Gauge Models: ZP, ZPH and ZPS
ZP Recorder Force Data Analyzer For Force Gauge Models: ZP, ZPH and ZPS INSTRUCTION MANUAL 2 YEAR WARRANTY (RESTRICTIONS APPLY) Imada, Inc. warrants its products to the original purchaser to be free from
More informationFLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.
FLOWgate500 Software Manual Software Manual FLOWgate500 Release 2.2 Revision number: V2.2 Manufacturer: SICK AG Erwin-Sick-Str.1 D-79183 Waldkirch Germany Place of manufacture: SICK Engineering GmbH Bergener
More informationNuFlo TM. SCM Viewer TM. User Manual. Manual No , Rev. A
NuFlo TM SCM Viewer TM User Manual Manual No. 30165020, Rev. A Revision History The following table shows the revision history for this document: Date Description Approved by 2-6-2006 Initial release of
More informationMULTITERM Pro G2 and G3 RF
MULTITERM Pro G2 and G3 RF INSTALLATION AND USER GUIDE Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg TEL: +45 89 93 10 00 FAX: +45 89 93 10 01 info@kamstrup.com www.kamstrup.com Contents 1
More informationKYOCERA Net Viewer 5.3 User Guide
KYOCERA Net Viewer. User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable
More informationConversion Software User Guide for
JANUARY 2018 CDS Conversion Software User Guide for Windows Version 2.0 Table of Contents CDS Conversion Software V2 for Windows User Guide... 1 System Requirements... 1 Introduction... 1 Installing CDS
More informationFiery X3eTY2 65_55C-KM Color Server. Utilities
Fiery X3eTY2 65_55C-KM Color Server Utilities 2008 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45072888 14 March 2008 CONTENTS 3 CONTENTS
More informationUser Manual WatchPower
User Manual WatchPower Management Software for SP Efecto / SP Brilliant (Plus) / SP Initial Table of Contents 1. WatchPower Overview...1 1.1. Introduction... 1 1.2. Features... 1 2. WatchPower Install
More informationNikon Message Center
Nikon Message Center Notice to Users in Europe and the U.S.A 2 Automatic Update 3 Checking for Updates Manually 3 4 Available Messages 5 My Products 6 Scheduling Updates 6 The Download Log 7 Uninstalling
More informationLinks to Activities ACTIVITY 1.1. Links to Activities Links to Activities
EXCEL Analyzing Data Using Excel Section 1 Skills Start Excel and identify features in the Excel window Enter labels and values Use the fill handle to enter a series Enter formulas Create a formula using
More informationN2KExtractor. Maretron Data Extraction Software User s Manual
N2KExtractor Maretron Data Extraction Software User s Manual Revision 3.1.6 Copyright 2017 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com
More informationTable of Contents.
Table of Contents http://www.advancedactuators.com 1. Items Included with the ThumbLock PCMU:... 2 2. IMPORTANT NOTE:... 2 3. Supported Operating Systems:... 2 Section 1 Installing the ThumbLock PCMU Software...
More informationUser Manual pdoc Signer
User Manual pdoc Signer August 11, 2014 Copyright 1995-2014 Topaz Systems Inc. All rights reserved. For Topaz Systems, Inc. trademarks, visit www.topazsystems.com/information/legal.htm#trademarks. www.topazsystems.com
More informationGreyline Logger. Greyline Logger
Contents Index Greyline Logger Menu Commands File Edit View Data Logging Communication Connection Setup... Remote Modems Export Graph... Text/Data Only Export ToolBar and Buttons Hotkeys & Shortcuts Summary
More informationQuick Reference Guide
Media Player SB-L008KU Quick Reference Guide Version 1.1 NEC Display Solutions, Ltd. Notes The windows in the actual software may differ somewhat from those shown in this manual. No part of the contents
More informationUser Manual. Consumer OneClick Internet. for Gobi Sierra Version st May 2010
User Manual Consumer OneClick Internet for Gobi 2000 Sierra Version 1.8 21 st May 2010 WebToGo Mobiles Internet GmbH 81371 München, Oberländerstr. 2a Table of Content 1. General 2. Starting OneClick Connection
More information