QPHY-MIPI-D-PHY. Instruction Manual

Size: px
Start display at page:

Download "QPHY-MIPI-D-PHY. Instruction Manual"

Transcription

1 QPHY-MIPI-D-PHY MIPI D-PHY Serial Data Compliance Software Instruction Manual Revision A November, 2017 Relating to: XStreamDSO v.8.5.x.x and later QualiPHY Software v.8.5.x.x and later f

2 700 Chestnut Ridge Road Chestnut Ridge, NY, Tel: (845) , Fax: (845) teledynelecroy.com 2017 Teledyne LeCroy, Inc. All rights reserved. Customers are permitted to duplicate and distribute Teledyne LeCroy documentation for internal training purposes. Unauthorized duplication is strictly prohibited. Teledyne LeCroy and other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice Rev A November, 2017

3 Table of Contents QPHY-MIPI-D-PHY Instruction Manual Introduction... 1 About QualiPHY... 1 About QPHY-MIPI-D-PHY... 1 Required Equipment... 1 Optional Equipment... 2 Required Host Computer System... 4 Installation and Setup... 5 Install Base Application... 5 Activate Components... 5 Set Up Dual Monitor Display... 5 Set Up Remote Control... 6 Configure Oscilloscope for Remote Control... 6 Add Connection to QualiPHY... 6 Select Connection... 6 Using QualiPHY... 7 Accessing the Software... 7 General Setup... 8 Connection tab... 8 Session Info tab... 8 Report tab... 8 Advanced tab... 8 About tab... 8 QualiPHY Test Process... 9 Set Up Test Session... 9 Run Tests Run Reports Customizing QualiPHY Copy Configuration Select Tests Edit Variables Edit Test Limits X-Replay Mode QPHY-MIPI-D-PHY Testing Test Preparation Required Test Modes QPHY-MIPI-D-PHY Test Configurations Dp-Dn-CLKp-CLKn LP tests (4 probes) Dp-Dn-CLKp-CLKn HS tests (4 probes) Dp-Dn-CLKp-CLKn Eye Diagram tests (Debug) Demo of all conformance tests Demo of debug tests QPHY-MIPI-D-PHY Test Descriptions Eye Diagrams (High Speed) HS Tests LP Tests QPHY-MIPI-D-PHY Variables Main Settings Script Settings Variables Demo Settings Variables Probe Setup <Setup> Variables QPHY-MIPI-D-PHY Limit Sets Appendix A: Manual Deskewing Procedures Cable Deskewing Using the Fast Edge Output Cable Deskewing Without Using the Fast Edge Output Rev Error! Reference source not found. i

4 Table of Figures Figure 1 - QualiPHY framework dialog and Standard selection menu....7 Figure 2 - The Test Report Summary and Details pages Figure 3 Configuration Test Selector tab Figure 4 X-Replay Mode window Figure 5 - The Skew parameter right side dialog, Skew clock 2 tab, showing default setup About This Manual This manual assumes that you are familiar with using an oscilloscope in particular the Teledyne LeCroy oscilloscope that will be used with QualiPHY and that you have purchased the QPHY-MIPI-D-PHY software option. Some of the images in this manual may show QualiPHY products other than QPHY- MIPI-D-PHY, or were captured using different model oscilloscopes, as they are meant to illustrate general concepts only. Rest assured that while the user interface may look different from yours, the functionality is identical. ii

5 QPHY-MIPI-D-PHY Instruction Manual Introduction About QualiPHY QualiPHY is highly automated compliance test software meant to help you develop and validate the PHY (physical-electrical) layer of a device, in accordance with the official documents published by the applicable standards organizations and special interest groups (SIGs). You can additionally set custom variables and limits to test compliance to internal standards. QualiPHY is composed of a framework application that enables the configuration and control of separate tests for each standard through a common user interface. Features include: Multiple Data Source Capability User-Defined Test Limits: Tighten limits to ensure devices are well within the passing region, even if subsequently measured with different equipment. Flexible Test Results Reporting that includes XML Test Record Generation. Understand a device performance distribution, or obtain process related information from the devices under test. About QPHY-MIPI-D-PHY QPHY-MIPI-D-PHY is an automated test package designed to capture, analyze, and report measurements in conformance with MIPI Alliance Specification for D-PHY version It can be run on any Teledyne LeCroy oscilloscope with at least 4 GHz Bandwidth and 20 GS/s Sample Rate. Required Equipment Teledyne LeCroy real-time oscilloscope, 4 GHz BW, installed with: o o XStreamDSO v.6.3.x.x minimum* with an activated QPHY-MIPI-D-PHY option key QualiPHY v.6.3.x.x minimum with an activated QPHY-MIPI-D-PHY component Four (4) differential probes and platform cable assemblies *Note: The versions of XStreamDSO and QualiPHY software must match, so upgrade your version of QualilPHY if you have upgraded your oscilloscope firmware. The versions listed above are the minimum versions required for this product. The QualiPHY software may be installed on a remote PC, but all other software must be run on the oscilloscope Rev Error! Reference source not found. 1

6 Optional Equipment These test fixtures are available from the University of New Hampshire InterOperability Laboratory (UNH-IOL) MIPI D-PHY reference termination board MIPI TLIS board 2

7 QPHY-MIPI-D-PHY Instruction Manual MIPI D-PHY probing board Rev Error! Reference source not found. 3

8 SMA alignment fixture SMA couplers For the most complete and up-to-date list, see the UNH-IOL website: Required Host Computer System Usually, the oscilloscope is the host computer for the QualiPHY software, and all models that meet the acquisition requirements will also meet the host system requirements. However, if you wish to run the QualiPHY software from a remote computer, these minimum requirements apply: Operating System: o o Windows 7 Professional Windows 10 Professional 1 GHz or faster processor 1 GB (32-bit) or 2 GB (64-bit) of RAM Ethernet (LAN) network capability Hard Drive: o At least 100 MB free to install the framework application o Up to 2 GB per standard installed to store the log database (each database grows from a few MB to a maximum of 2 GB) See Set Up Remote Control for configuration instructions. 4

9 Installation and Setup QPHY-MIPI-D-PHY Instruction Manual QualiPHY is a Windows-based application that can be configured with one or more serial data compliance components. Each compliance component is purchased as a software option. Install Base Application Download the latest version of the QualiPHY software from: teledynelecroy.com/support/softwaredownload under Oscilloscope Downloads > Software Utilities. If the oscilloscope is not connected to the Internet, copy the installer onto a USB memory stick then transfer it to the oscilloscope desktop or a folder on a D:\ drive to execute it. Run QualiPHYInstaller.exe and follow the installer prompts. Choose all the components you plan to activate. If you omit any components now, you will need to update the installation to activate them later. By default, the oscilloscope appears as local host when QualiPHY is executed on the oscilloscope. Follow the steps under Add Connection to QualiPHY to check that the IP address is Activate Components The serial data compliance components are factory installed as part of the main application in your oscilloscope and are individually activated through the use of an alphanumeric code uniquely matched to the oscilloscope s serial number. This option key code is what is delivered when purchasing a software option. To activate a component on the oscilloscope: 1. From the menu bar, choose Utilities > Utilities Setup. 2. On the Options tab, click Add Key. 3. Use the Virtual Keyboard to Enter Option Key, then click OK. If activation is successful, the key code now appears in the list of Installed Option Keys. 4. Restart the oscilloscope application by choosing File > Exit, then double-clicking the Start DSO icon on the desktop. Set Up Dual Monitor Display Teledyne LeCroy recommends running QualiPHY on an oscilloscope equipped with Dual Monitor Display capability. This allows the waveform and measurements to be shown on the oscilloscope LCD display while the QualiPHY application and test results are displayed on a second monitor. See the oscilloscope Operator s Manual or Getting Started Manual for instructions on setting up dual monitor display Rev Error! Reference source not found. 5

10 Set Up Remote Control QualiPHY software can be executed from a remote host computer, controlling the oscilloscope through a LAN Connection. To set up remote control: The oscilloscope must be connected to a LAN and assigned an IP address (fixed or dynamic). The host computer must be on the same LAN as the oscilloscope. Configure Oscilloscope for Remote Control 1. From the menu bar, choose Utilities Utilities Setup Open the Remote tab and set Remote Control to TCP/IP. 3. Verify that the oscilloscope shows an IP address. Add Connection to QualiPHY 1. On the host PC, download and run QualiPHYInstaller.exe. 2. Start QualiPHY and click the General Setup button. 3. On the Connection tab, click Scope Selector. 4. Click Add and choose the connection type. Enter the oscilloscope IP address from Step 3 above. Click OK. 5. When the oscilloscope is properly detected, it appears on the Scope Selector dialog. Select the connection, and click OK. QualiPHY is now ready to control the oscilloscope. Select Connection Multiple oscilloscopes may be accessible to a single remote host. In that case, go to General Setup and use the Scope Selector at the start of the QPHY session to choose the correct connection. QualiPHY tests the oscilloscope connection when starting a test. The system warns you if there is a connection problem. 6

11 Using QualiPHY QPHY-MIPI-D-PHY Instruction Manual This section provides an overview of the QualiPHY user interface and general procedures. For detailed information about the QPHY-MIPI-D-PHY software option, see QPHY-MIPI-D-PHY Testing. Accessing the Software Once QualiPHY is installed and activated, it can be accessed from the oscilloscope menu bar by choosing Analysis > QualiPHY, or by double-clicking the QualiPHY desktop icon on a remote computer. The QualiPHY framework dialog illustrates the overall software flow, from general set up through running compliance tests. Work from left to right, making all desired settings on each sub-dialog. Figure 1 - QualiPHY framework dialog and Standard selection menu. The sub-dialogs are organized into tabs each containing configuration controls related to that part of the process. These are described in more detail in the following sections. If Pause on Failure is checked, QauliPHY prompts to retry a measure whenever a test fails. Report Generator launches the manual report generator dialog. The Exit button at the bottom of the framework dialog closes the QualiPHY application Rev Error! Reference source not found. 7

12 General Setup The first sub-dialog contains general system settings. These remain in effect for each session, regardless of Standard, until changed. Connection tab Shows IP Address of the test oscilloscope (local host if QualiPHY is run from the oscilloscope). The Scope Selector allows you to choose the oscilloscope used for testing when several are connected to the QualiPHY installation. See Set Up Remote Control for details. Session Info tab Optional information about the test session that may be added to reports, such as: Operator Name, Device Under Test (DUT), Temperature (in C) of the test location, and any additional Comments. There is also an option to Append Results or Replace Results when continuing a previous session. To optimize report generation, enter at least a DUT name at the beginning of each session. Report tab Settings related to automatic report generation. Choose: Reporting behavior of: o o o Ask to generate a report after tests, where you ll be prompted to create a new file for each set of test results. Never generate a report after tests, where you ll need to manually execute the Report Generator to create a report. Always generate a report after tests, to autogenerate a report of the latest test results. Default report output type of XML, HTML, or PDF. A generic Output file name, including the full path to the report output folder. Optionally, check Allow style sheet selection in Report Generator to enable the use of a custom.xslt when generating reports (XML and HTML output only). The path to the.xslt is entered on the Report Generator dialog. Report Generator launches the Report Generator dialog, which contains the same settings as the Report tab, only applied to individual reports. Advanced tab This tab launches the X-Replay Mode dialog. See X-Replay Mode. About tab Information about your QualiPHY installation. 8

13 QPHY-MIPI-D-PHY Instruction Manual QualiPHY Test Process Once general system settings are in place, these are the steps for running test sessions. Set Up Test Session 1. Connect the oscilloscope to the DUT. See QPHY-MIPI-D-PHY Testing Physical Setup. 2. Access the QualiPHY software to display the framework dialog. 3. If running QualiPHY remotely, click General Setup and open the Scope Selector to select the correct oscilloscope connection. 4. If you have more than one component activated, click Standard and select the desired standard to test against. Otherwise, your one activated component will appear as the default selection. Note: Although all the QualiPHY components appear on this dialog, only those selected when installing QualiPHY are enabled for selection now. 5. Click the Configuration button and select the test configuration to run. These pre-loaded configurations are set up to run all the tests required for compliance and provide a quick, easy way to begin compliance testing. See QPHY-MIPI-D-PHY Test Configurations for a description of your configurations. You can also create custom configurations for internal compliance tests by copying and modifying the pre-loaded configurations. See Customizing QualiPHY for details. 6. Close the Edit/View Configuration dialog to return to the framework dialog Rev Error! Reference source not found. 9

14 Run Tests 1. On the framework dialog, click Start to begin testing. When tests are in progress, this button changes to Stop. Click it at any time to stop the test in process. You ll be able to resume from the point of termination or from the beginning of the test. 2. Follow the pop-up window prompts. QualiPHY guides you step-by-step through each of the tests described in the standard specification, including diagrams of the connection to the DUT for each required test mode. 3. When all tests are successfully completed, both progress bars on the framework dialog are completely green and the message All tests completed successfully appears. If problems are encountered, you ll be offered options to: Retry the test from the latest established point defined in the script Ignore and Continue with the next test Abort Session 10

15 QPHY-MIPI-D-PHY Instruction Manual Run Reports The QualiPHY software automates report generation. On the framework dialog, go to General Setup > Report to pre-configure reporting behavior. You can also manually launch the Report Generator from the framework dialog once a test is run. The Report Generator offers the same selections as the Report tab, only applied to each report individually, rather than as a system setting. This enables you to save reports for each test session, rather than overwrite the generic report file. There are also options to link a custom style sheet (.xslt) to the report, or to Exclude Informative Results. The Test Report includes a summary table with links to the detailed test result pages. Figure 2 - The Test Report Summary and Details pages. Reports are output to the folder C:\LeCroy\QPHY\Reports. You can add your own logo to the report by replacing the file C:\LeCroy\QPHY\StyleSheets\CustomerLogo.jpg. The recommended maximum size is 250x100 pixels at 72 ppi, 16.7 million colors, 24 bits. Use the same file name and format Rev Error! Reference source not found. 11

16 Customizing QualiPHY The pre-loaded configurations cannot be modified. However, you can create your own test configurations by copying one of the standard test configurations and modifying it. Copy Configuration 1. Access the QualiPHY framework dialog and select a Standard. 2. Click Edit/View Configuration and select the configuration upon which to base the new configuration. This can be a pre-loaded configuration or another copy. 3. Click Copy and enter a name and description. Once a custom configuration is defined, it appears on the Configuration tab followed by (Copy). 4. Select the new, custom configuration and follow the procedures below to continue making changes. Note: If any part of a configuration is changed, the Save As button becomes active on the bottom of the dialog. If a custom configuration is changed, the Save button will also become active to apply the changes to the existing configuration. 12

17 QPHY-MIPI-D-PHY Instruction Manual Select Tests On the Test Selector tab, check the tests that make up the configuration. Each test is defined by the MIPI-D-PHY standard. A description of each test is displayed when it is selected. To loop any of the tests in this configuration, select the test from the list, then choose to Loop the highlighted test until stopped or enter the number of repetitions. Figure 3 Configuration Test Selector tab Rev Error! Reference source not found. 13

18 Edit Variables The Variable Setup tab contains a list of test variables. See QPHY-MIPI-D-PHY Variables for a description of each. To modify a variable: 1. Select the variable on the Variable Setup tab, then click Edit Variable. (You can also choose to Reset to Default at any time.) 2. The conditions of this variable appear on a pop-up. Choose the new condition to apply. 14

19 QPHY-MIPI-D-PHY Instruction Manual Edit Test Limits The Limits tab shows the Limit Set currently associated with the configuration. Any limit set can be associated with a custom configuration by selecting it in this field. The Limits Manager shows the settings for every test limit in a limit set. Those in the default set are the limits defined by the standard. To create a custom limit set: 1. On the Limits tab, click Limits Manager. 2. With the default set selected, click Copy Set and enter a name. Note: You can also choose to copy and/or modify another custom set that has been associated with this configuration. 3. Double click the limit to be modified, and in the pop-up enter the new values. You can also Import Limits from a.csv file. Navigate to the file location after clicking the button. Tip: Likewise, Export Limits creates a.csv file from the current limit set. You may wish to do this and copy it to format the input.csv file Rev Error! Reference source not found. 15

20 X-Replay Mode The X-Replay mode window is an advanced ( developer ) view of QualiPHY. The tree in the upper-left frame enables you to navigate to processes in the MIPI-D-PHY test script, in case you need to review the code, which appears in the upper-right frame. Two other particularly useful features are: A list of recent test sessions in the lower-left frame. While you can only generate a report of the current test session in the QualiPHY wizard, in X-Replay Mode you can generate a report for any of these recent sessions. Select the session and choose Report > Create Report from the menu bar. The QualiPHY log in the bottom-right frame. The frame can be split by dragging up the lower edge. The bottom half of this split frame now shows the raw Python output, which can be useful if ever the script needs debugging. Figure 4 X-Replay Mode window 16

21 QPHY-MIPI-D-PHY Instruction Manual QPHY-MIPI-D-PHY Testing Test Preparation Before beginning any test or data acquisition, the oscilloscope should be warmed for at least 20 minutes. Calibration is automatic under software control and no manual calibration is required. This procedure will be run again if the temperature of the oscilloscope changes by more than a few degrees. Required Test Modes The QPHY-MIPI-D-PHY script requires that you place the DUT (Device Under Test) in the required test modes. The script will prompt you to do so before each specific test, but it is recommended that you ensures the DUT is capable of being placed in the required test modes before beginning testing. QPHY-MIPI-D-PHY Test Configurations Test configurations include variable settings, limit sets, and test selections. See QPHY-MIPI-D-PHY Variables for a description of each variable and its default value. To save the waveforms acquired, change the variable Save Acquired Waveforms in the Default variable set to Yes. Dp-Dn-CLKp-CLKn LP tests (4 probes) This configuration will run all LP tests using the Default variable set. Dp-Dn-CLKp-CLKn HS tests (4 probes) This configuration will run all HS tests using the Default variable set. Dp-Dn-CLKp-CLKn Eye Diagram tests (Debug) This configuration will run all Eye Diagram tests using the Default variable set. Demo of all conformance tests This configuration will run a demonstration of all conformance tests using waveforms stored in the oscilloscope D: directory. All variables are set to defaults, except Use Stored Waveforms is set to Yes. Demo of debug tests This configuration will run a demonstration of debug tests (i.e., Eye Diagram) using waveforms stored in the oscilloscope D: directory. All variables are set to defaults, except Use Stored Waveforms is set to Yes Rev Error! Reference source not found. 17

22 QPHY-MIPI-D-PHY Test Descriptions The descriptions for the following tests performed by QPHY-MIPI-DPHY can be found in the MIPI Alliance Test Program D-PHY Physical Layer Conformance Test Suite Version The tests within each configuration are organized by probe setup. Conformance tests use the probe setup Dp-Dn-CLKp-CLKn. If tests using other probe setups are selected for custom configurations, the user is prompted to change setups as needed while the test is running. Eye Diagrams (High Speed) 18 Dp Dn Ddiff CLKp CLKn CLKdiff HS Tests Data Lane HS Bitrate and UI VOD(1,0) (Clock and Data) dvod(1,0) (Clock and Data) VOHHS (Clock and Data) VCMTX(1,0) (Clock and Data) dvcmtx(1,0) (Clock and Data) TR / TF (Clock and Data) dvcmtx(hf) and dvcmtx(lf) (Clock and Data) TLPX (Clock and Data) THS-Prepare (Data Only) THS-Prepare+THS-Zero (Data Only) THS-Trail (Data Only) THS-Exit (Clock and Data) TEOT (Clock and Data) TREOT (Clock and Data) TCLK-Trail (Clock Only) TLK-Prepare (clock Only) TCLK-Prepare+TCLK-Zero (Clock Only) TCLK-Pre (Clock to Data Timing) TCLK-Post (Clock to Data Timing) First Bit (Clock to Data Timing) TSkew (Clock to Data Timing) LP Tests VOH / VOL (Clock and Data)

23 QPHY-MIPI-D-PHY Instruction Manual TRLP / TFLP (Clock and Data) Maximum Slew Rate (Clock and Data) Minimum Slew Rate (Clock and Data) Minimum Rising (Clock and Data) Minimum Rising (Clock and Data) TLP-Pulse-Tx (Data Only) TLP-Per-Tx (Data Only) Rev Error! Reference source not found. 19

24 QPHY-MIPI-D-PHY Variables Main Settings Clock N Signal Name This variable is used to specify the Clock Negative Signal. The default value is CLKn. DUT Bit Rate in High-Speed Mode in Mbps This variable is used to set the oscilloscope timebase and sampling rate, see Clock Period Per Screen Division for more explanation. The default value is 650 Mbps. Note from the MIPI Specification: The actual maximum achievable bit rate in High-Speed mode is determined by the performance of transmitter, receiver and interconnect implementations. Therefore, the maximum bit rate is not specified in this document. However, this specification is primarily intended to define a solution for a bit rate range of 80 to 1000 Mbps per Lane. Although PHY Configurations are not limited to this range, practical constraints make it the most suitable range for the intended applications. It is anticipated a typical implementation will have a bit rate of approximately 650 Mbps per Lane. DUT IC Supply Voltage This variable is used to specify the IC supply voltage for the device under test. The default value is 1.2V Clock P Signal Name This variable is used to specify the Clock Positive Signal. The default value is CLKp. Data N Signal Name This variable is used to specify the Data Negative Signal. The default value is Dn. Data P Signal Name This variable is used to specify the Data Positive Signal. The default value is Dp. Clock Diff Signal Name Name of Clock Differential Signal. Default is CLKdiff. Data Diff Signal Name Name of Data Differential Signal. Default is Ddiff. Select Measure on All or One HS Burst This variable allows you to select whether to perform all high speed measurements on the entire acquired waveform or only on one burst at a time. This was included as an advanced debugging giving higher statistical stability capability. The default for this variable is All Bursts. Select Index When Measuring One Burst This variable allows you to manually specify the burst index (number) of the burst that they would like to measure. This index does not count partial bursts at the beginning of the waveform. Default is 1. XRCV_HS_PARTIALBURSTS Allows partial bursts in all HS measurements. Should only be set if bursts are very long, so measurements are made at the end of one burst and the beginning of the next burst. May be needed for DSI. 20

25 QPHY-MIPI-D-PHY Instruction Manual Script Settings Variables Stop on Test to Review Results This variable allows you to pause the execution of QualiPHY after each test. The default value is No. When set to Yes, the script will stop after each test to allow for result reviewing. The setup will be saved so that oscilloscope settings can be modified by you. On resume, the setup will be recalled. Note that any new acquisition done in the meantime might cause the script to misbehave. Silent Mode Control This variable is used to set QualiPHY to run in silent mode. In silent mode, no user interaction is required. The default value is No. Save Acquired Waveforms This variable is used to specify whether to save the acquired waveforms or not. The default value is No. This setting is ignored if the Use Stored Waveforms variable is set to Yes. Waveforms will be saved in the directories specified by the variables Waveform Path, Folder for HS Waveforms and Folder for LP Waveforms. Waveform Path Full path to the oscilloscope folder used to save/recall waveforms. When not in Demo Mode and Save acquired waveforms is enabled, waveform files are saved in this folder. When in Demo Mode or set to Use Stored Traces, saved waveforms are recalled from this folder. The default value for this variable is D:\Waveforms\MIPIDPHY. Demo Settings Variables Recall Waveform File Index (5 digits) 5-digit number of the waveform file to use when running demo configurations (multiple waveforms stored in the same directory will be numbered 00000, 00001, 00002, etc.). Default is Use Stored Waveforms This variable allows you to run the selected tests on previously saved waveforms. The default value is No for conformance tests, Yes for demo configuration tests. Define Format Used to Set Trace Names This variable allows you to specify the waveform file name format. Choices are: LeCroy: compose waveform names automatically from signal names Dialog: Manually enter waveform names Custom: Set the name of the waveform in the XX HS Filename and XX LP Filename variables Rev Error! Reference source not found. 21

26 Probe Setup <Setup> Variables These variables are repeated for each test group (LP, HS, and Eye Diagram) within each type of probe setup. <Signal> Channel Index This variable allows you to manually specify the channel used to acquire the respective signal Dp, Dn, CLKp or CLKn. The default values are 1 for Dp, 2 for Dn, 3 for CLKp and 4 for CLKn. <Signal> Channel Invert This variable allows you to invert the respective signal. Default is False. Data Lanes This variable allows you to specify the Data Lane(s) tested. Any subset of D0, D1, D2, or D3 is accepted. Set all Data Lanes the DUT implements for a complete validation. The default value is D0. Folder for <LP HS > Waveforms This variable allows you to specify the name of the subfolder that will be created inside the Waveform Path folder for storing the LP or HS waveforms. ZID Termination Values for <LP HS> (in Ohms) This allows you to set the termination values for the lane under test for the respective mode. Running test with each value (50,Open) is a specification requirement. You can set a subset in case the lane termination cannot be controlled (partial validation). <Signal> Filename This variable allows you to specify the name of the waveform file to be used for the respective signal when running on saved waveforms. This file is only used when Use Saved Waveforms is set to Yes. 22

27 HS Mode Forward / Reverse Direction This variable is used to compute THS-TRAIL min limit: (max( n*8*ui, 60 ns + n*4*ui ) Where n = 1 for Forward-direction HS mode and n = 4 for Reverse-direction HS mode QPHY-MIPI-D-PHY Instruction Manual Reverse-direction is a special mode of transmission of HS-Data. MIPIDPHY spec. definition: A Lane enters the Reverse High-Speed Data Transmission mode by means of a Link Turnaround procedure as specified in section 5.5. Reverse Data Transmission is not source-synchronous; the Clock signal is driven by the Master side while the Data Lane is driven by the Slave side. The Slave Side transmitter shall send one data bit every two periods of the received Clock signal. Therefore, for a given Clock frequency, the Reverse direction data rate is one-fourth the Forward direction data rate. The bit period in this case is defined to be 4*UIINST. UIINST is the value specified for the full-rate forward transmission. DUT UI Inst Minimum Value This variable allows you to specify the minimum instantaneous UI possible within a High-Speed data transfer for a given implementation. This value must be obtained from the DUT vendor. The default value is 1e-9. on of HS-Data. QPHY-MIPI-D-PHY Limit Sets The default installation of QPHY-MIPI-D-PHY contains only one limit set, called Default. In this script, limits are only used to convey Unit labels. The actual limits for each value tested are encoded in or computed by the script and cannot be changed Rev Error! Reference source not found. 23

28 Appendix A: Manual Deskewing Procedures This section is only applicable to the oscilloscope and the cables connecting to the oscilloscope channels.. Cable Deskewing Using the Fast Edge Output The following procedure demonstrates how to manually deskew two oscilloscope channels and cables using the fast edge output, with no need for any T connector or adapters. Note: Fast Edge output is available only on some models. If your oscilloscope does not have Fast Edge output, see Cable Deskewing Without Using the Fast Edge Output. This can be done once the temperature of the oscilloscope is stable. The oscilloscope must be warmed up for at least 20 min. before proceeding. This procedure should be run again if the temperature of the oscilloscope changes by more than a few degrees. For the purpose of this procedure, the two channels being deskewed are referred to as Channel X and Channel Y. The reference channel is Channel X and the channel being deskewed is Channel Y. 1. Begin by recalling the Default Oscilloscope Setup. 2. Configure the oscilloscope as follows: Timebase i. Fixed Sample Rate ii. Set the Sample Rate to 40 GS/s iii. Set the Time/Division to 1 ns/div Channels i. Turn on Channel X and Channel Y. ii. Set V/div for Channel X and Channel Y to 100mV/div. iii. Set the Averaging of Channel X and Channel Y to 500 sweeps. iv. Set the Interpolation of Channel X and Channel Y to Sinx/x. 24

29 QPHY-MIPI-D-PHY Instruction Manual Trigger i. Configure to Source to be FastEdge. ii. Set the Slope to Positive. Parameter Measurements: i. Set the source for P1 to CX and the measure to Delay. ii. Set the source for P2 to CY and the measure to Delay. iii. Set the source for P3 to M1 and the measure to Delay. 3. Set the display to Single Grid. Click Display Single Grid. 4. Using the appropriate adapter, connect Channel X to the Fast Edge Output of the oscilloscope. 5. Adjust the Trigger Delay so that the Channel X signal crosses at the center of the screen. 6. Change the Timebase to 50 ps/div. 7. Fine tune the Trigger Delay so that the Channel X signal crosses at the exact center of the screen. 8. Press the Clear Sweeps button on the front panel to reset the averaging. 9. Allow multiple acquisitions to occur until the waveform is stable on the screen Rev Error! Reference source not found. 25

30 10. Save Channel X to M1. Click File Save Waveform. Set Save To Memory. Set the Source to CX. Set the Destination to M1. Click Save Now. 11. Disconnect Channel X from the Fast Edge Output and connect Channel Y to the Fast Edge Output. 12. Press the Clear Sweeps button on the front panel to reset the averaging. 13. Allow multiple acquisitions to occur until the waveform is stable on the screen. 14. From the Channel Y menu, adjust the Deskew of Channel Y until Channel Y is directly over the M1 trace. 15. Ensure that P3 and P2 are reasonably close to the same value. (Typically < 5ps difference) 26

31 UU QPHY-MIPI-D-PHY Instruction Manual Cable Deskewing Without Using the Fast Edge Output The following procedure demonstrates how to manually deskew two oscilloscope channels and cables using the differential data signal, with no need for any T connector or adapters. This can be done once the temperature of the oscilloscope is stable. The oscilloscope must be warmed up for at least a half-hour before proceeding. This procedure should be run again if the temperature of the oscilloscope changes by more than a few degrees. 1. Connect a differential data signal to C1 and C2 using two approximately matching cables. Set up the oscilloscope to use the maximum sample rate. Set the timebase for a few repetitions of the pattern (at least a few dozen edges). 2. On the C3 menu, check Invert. Now C1 and C2 should look the same. 3. Using the Measure Setup, set P1 to measure the Skew of C1, C2. Turn on Statistics (Measure menu). Write down the mean skew value after it stabilizes. This mean skew value is the addition of Data skew + cable skew + channel skew. 4. Swap the cable connections on the Data source side (on the test fixture), and then press the Clear Sweeps button on the oscilloscope (to clear the accumulated statistics; since we changed the input). 5. Write down the mean skew value after it stabilizes. This mean skew value is the addition of (- Data skew) + cable skew + channel skew. 6. Add the two mean skew values and divide the sum in half: [Data skew + cable skew + channel skew] + [ (-Data skew) + cable skew + channel skew]uu 2 The above formula simplifies to: [cable skew + channel skew] 7. Set the resulting value as the Deskew value in C1 menu. 8. Restore the cable connections to their Step 1 settings (previous). Press the Clear Sweeps button on the oscilloscope. The mean skew value should be approximately zero - that is the data skew. Typically, results are <1ps given a test fixture meant to minimize skew on the differential pair. 9. On the C2 menu, clear the Invert checkbox and turn off the parameters Rev Error! Reference source not found. 27

32 In the previous procedure, we used the default setup of the Skew parameter (which is detecting positive edges on both signals at 50%). We also inverted C2 in order to make C1 and C2 both have positive edges at the same time. Alternately, we clearly could have not inverted C2 and instead selected the Skew clock 2 tab in the P1 parameter menu and set the oscilloscope to look for negative edges on the second input (C2). However, we believe that the previous procedure looks much more aesthetically pleasing from the display as it shows C2 and C3 with the same polarity. Figure 5 - The Skew parameter right side dialog, Skew clock 2 tab, showing default setup. 28

33

QPHY-10GBase-KR Operator s Manual

QPHY-10GBase-KR Operator s Manual QPHY-10GBase-KR Operator s Manual Revision A May, 2014 Relating to the following release versions: Software Version Rev. 7.3.x.x Script 10GBase-KR.IRT Style Sheet Rev. 1.2 700 Chestnut Ridge Road Chestnut

More information

QPHY-PCIE (Gen1 and Gen2) Operator s Manual

QPHY-PCIE (Gen1 and Gen2) Operator s Manual QPHY-PCIE (Gen1 and Gen2) Operator s Manual Revision B November, 2017 Relating to: XStreamDSO Version 8.5.x.x QualiPHY Version 8.5.x.x 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845)

More information

QPHY-PCIE3 Operator s Manual

QPHY-PCIE3 Operator s Manual QPHY-PCIE3 Operator s Manual Revision B November, 2017 Relating to: XStreamDSO Version 8.5.x.x QualiPHY Version 8.5.x.x 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax:

More information

QPHY-SFI. Instruction Manual

QPHY-SFI. Instruction Manual QPHY-SFI SFI Serial Data Compliance Software Instruction Manual Revision C November, 2017 Relating to: XStreamDSO v.8.5.x.x and later QualiPHY v.8.5.x.x and later 700 Chestnut Ridge Road Chestnut Ridge,

More information

QPHY-PCIE3-TX-RX Operator s Manual

QPHY-PCIE3-TX-RX Operator s Manual QPHY-PCIE3-TX-RX Operator s Manual Revision C November, 2017 Relating to: XStreamDSO Version 8.5.x.x QualiPHY Version 8.5.x.x 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000,

More information

QPHY-USB3.1-TX-RX. Instruction Manual

QPHY-USB3.1-TX-RX. Instruction Manual QPHY-USB3.1-TX-RX USB3.1 Serial Data Compliance Software Instruction Manual Revision A November, 2017 Related to version: XStreamDSO 8.5.x.x. QualiPHY 8.5.x.x. 700 Chestnut Ridge Road Chestnut Ridge, NY,

More information

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY Tel: (845) , Fax: (845) Internet:

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY Tel: (845) , Fax: (845) Internet: SDA-SAS Software Option Rev 1.1 Featuring LeCroy s Based on Clause 5 PHY Layer Tests from UNH-IOL Operator s Manual April 2006 LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY 10977 6499 Tel:

More information

MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET The InterOperability Laboratory MIPI D-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET Abstract: This document serves as the primary documentation for the MIPI D-PHY Reference Termination

More information

PCI Express Signal Quality Test Methodology

PCI Express Signal Quality Test Methodology PCI Express Signal Quality Test Methodology Users Guide LeCroy SDA 6000 October 2003 Revision 0.7 Document Number: XXXX DISCLAIMER OF WARRANTIES THIS SPECIFICATION IS PROVIDED AS IS AND WITH NO WARRANTIES

More information

JitKit. Operator's Manual

JitKit. Operator's Manual JitKit Operator's Manual March, 2011 LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 578-6020, Fax: (845) 578 5985 Internet: www.lecroy.com 2011 by LeCroy Corporation.

More information

Teledyne LeCroy. Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing

Teledyne LeCroy. Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing Teledyne LeCroy DisplayPort Standard April, 2016 Teledyne LeCroy MOI for DisplayPort PHY CTS 1.2b Source Testing This document is provided "AS IS" and without any warranty of any kind, including, without

More information

PCI Express 4.0. Electrical compliance test overview

PCI Express 4.0. Electrical compliance test overview PCI Express 4.0 Electrical compliance test overview Agenda PCI Express 4.0 electrical compliance test overview Required test equipment Test procedures: Q&A Transmitter Electrical testing Transmitter Link

More information

Agilent N5410A Fibre Channel Automated Test Application

Agilent N5410A Fibre Channel Automated Test Application Agilent N5410A Fibre Channel Automated Test Application Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced

More information

R&S ScopeSuite Release Notes Software Version 3.6.0

R&S ScopeSuite Release Notes Software Version 3.6.0 R&S Release Notes Software Version 3.6.0 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET

MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET The InterOperability Laboratory MIPI C-PHY REFERENCE TERMINATION BOARD (RTB) OVERVIEW AND DATASHEET Abstract: This document serves as the primary documentation for the MIPI C-PHY Reference Termination

More information

Keysight N8814A 10GBASE-KR Ethernet Backplane Electrical Performance Validation and Conformance

Keysight N8814A 10GBASE-KR Ethernet Backplane Electrical Performance Validation and Conformance Keysight N8814A 10GBASE-KR Ethernet Backplane Electrical Performance Validation and Conformance For Infiniium Oscilloscopes Data Sheet 02 Keysight N8814A 10GBASE-KR Ethernet Backplane Electrical Performance

More information

Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software

Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software Keysight Technologies N6468A SFP+ Electrical Performance Validation and Conformance Software For Infiniium Oscilloscopes Data Sheet 02 Keysight N6468A SFP+ Electrical Performance Validation and Conformance

More information

PCI Express 4.0 Test Solution

PCI Express 4.0 Test Solution PCI Express 4.0 Test Solution Key Features PCIe Gen4 CEM compliance testing: Transmitter preset and signal quality Transmitter link equalization Receiver test calibration Receiver jitter tolerance Fully

More information

Agilent N5394A DVI Electrical Performance Validation and Compliance Software

Agilent N5394A DVI Electrical Performance Validation and Compliance Software Agilent N5394A DVI Electrical Performance Validation and Compliance Software Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2004-2008 No part of this

More information

Keysight Technologies N6467A BroadR-Reach Automotive Ethernet Electrical Compliance Application

Keysight Technologies N6467A BroadR-Reach Automotive Ethernet Electrical Compliance Application Ihr Spezialist für Mess- und Prüfgeräte Keysight Technologies N6467A BroadR-Reach Automotive Ethernet Electrical Compliance Application For Infiniium Oscilloscopes Data Sheet Easy and accurate BroadR-Reach

More information

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests

Keysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests Revision 1.10 October 18, 2016 Universal Serial Bus Specification Revision 2.0 Keysight Method of Implementation (MOI) for USB 2.0 Connectors and Cables Assemblies Compliance Tests Using Keysight E5071C

More information

Enabling MIPI Physical Layer Test

Enabling MIPI Physical Layer Test Enabling MIPI Physical Layer Test High Speed Test and Characterization High Speed Digital Test The Explosion of Functions within Mobile Devices Multiple RF functions GPS Bluetooth WCDMA GSM WLAN FM Multiple

More information

Quick Reference Guide WaveRunner 6 Zi Oscilloscopes

Quick Reference Guide WaveRunner 6 Zi Oscilloscopes Quick Reference Guide WaveRunner 6 Zi Oscilloscopes To get started quickly, take a few moments to read through this guide. Additional information can be found in the Getting Started Manual. On-line help

More information

R&S RTO-K81, R&S RTP-K81 PCIe Compliance Test Test Procedures

R&S RTO-K81, R&S RTP-K81 PCIe Compliance Test Test Procedures PCIe Compliance Test Test Procedures (=QFñ2) 1333229902 Test Procedures Version 03 This manual describes the PCIe compliance test procedures with the following options: R&S RTO-K81 (1326.0920.02) - PCIe

More information

Help Volume Hewlett Packard Company. All rights reserved. Toolsets: IA Format Utility

Help Volume Hewlett Packard Company. All rights reserved. Toolsets: IA Format Utility Help Volume 1997-2002 Hewlett Packard Company. All rights reserved. Toolsets: IA Format Utility Using the IA Format Utility The IA Format Utility tool lets you convert a.r (dot R) file into an inverse

More information

Instruction Manual HIOKI Standby Power Measurement Software

Instruction Manual HIOKI Standby Power Measurement Software Instruction Manual HIOKI Standby Power Measurement Software This manual explains the free software (HIOKI Standby Power Measurement Software) for the HIOKI Power Meter series only. Please refer to the

More information

User Guide. 980 DisplayPort Link Layer Sink Compliance Tests

User Guide. 980 DisplayPort Link Layer Sink Compliance Tests User Guide 980 DisplayPort Link Layer Sink Compliance Tests Rev: A1 Page 1 March 24, 2017 Table of Contents 1 Overview 3 1.1 Scope of this User Guide 3 1.2 Changes to this User Guide 4 1.3 What options

More information

PCI Express 3.0 Characterization, Compliance, and Debug for Signal Integrity Engineers

PCI Express 3.0 Characterization, Compliance, and Debug for Signal Integrity Engineers PCI Express 3.0 Characterization, Compliance, and Debug for Signal Integrity Engineers - Transmitter Testing - Receiver Testing - Link Equalization Testing David Li Product Marketing Manager High Speed

More information

DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. June Rev 1.0

DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. June Rev 1.0 DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual June 2015 - Rev 1.0 1 MIPI DPhy Decoder 1.0 General: The MIPI DPhy v1.2 Decoder (DPhyDkd) is the hardware probe that supports

More information

xponent Version 4.2 RELEASE NOTES

xponent Version 4.2 RELEASE NOTES xponent Version 4.2 RELEASE NOTES Copyright Luminex Corporation, 1996-2013. All rights reserved. Part Number: 89-30000-00-462 Disclaimer Subject to change without notice. Although prepared to ensure accuracy,

More information

Keysight U7231B, U7231C DDR3 and LPDDR3 Compliance Test Application For Infiniium Series Oscilloscopes DATA SHEET

Keysight U7231B, U7231C DDR3 and LPDDR3 Compliance Test Application For Infiniium Series Oscilloscopes DATA SHEET Keysight U7231B, U7231C DDR3 and LPDDR3 Compliance Test Application For Infiniium Series Oscilloscopes DATA SHEET Test, Debug and Characterize Your DDR3 and LPDDR3 Designs Quickly and Easily The Keysight

More information

E2625A Communication Mask Test Kit E2698A Ethernet Masks

E2625A Communication Mask Test Kit E2698A Ethernet Masks E2625A Communication Mask Test Kit E2698A Ethernet Masks Data Sheet 43 industry-standard ANSI T1.102, ITU-T G.703, and IEEE 802.3 communication signal mask templates Mask testing for positive and negative

More information

GXLink MultiChannel Wave Inserter Model SP-631

GXLink MultiChannel Wave Inserter Model SP-631 800173-0A Digital High Speed GXLink MultiChannel Wave Inserter Model SP-631 User Manual Copyright 2009 It is prohibited to copy, reproduce or distribute this information in whole or in part without the

More information

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA Revision 1.01 Feb-24, 2017 Universal Serial Bus Type-C TM Specification Revision 1.1 Keysight Method of Implementation (MOI) for USB Type-C TM Cables Assemblies Compliance Tests Using Keysight For Type-C

More information

Help Volume Agilent Technologies. All rights reserved. Agilent E2485A Memory Expansion Interface

Help Volume Agilent Technologies. All rights reserved. Agilent E2485A Memory Expansion Interface Help Volume 1994-2002 Agilent Technologies. All rights reserved. Agilent E2485A Memory Expansion Interface Agilent E2485A Memory Expansion Interface The E2485A Memory Expansion Interface lets you use the

More information

Universal Serial Bus Implementers Forum Hub Hi-Speed Electrical Test Procedure For Yokogawa DL9240/DL9240L/DL6154

Universal Serial Bus Implementers Forum Hub Hi-Speed Electrical Test Procedure For Yokogawa DL9240/DL9240L/DL6154 Universal Serial Bus Implementers Forum Hub Hi-Speed Electrical Test Procedure For Yokogawa DL9240/DL9240L/DL6154 Revision 2.0 November 29, 2010 Revision History Rev Date Filename Comments 1.0 July-27-2006

More information

DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. March Rev 1.0

DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. March Rev 1.0 DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual March 2013 - Rev 1.0 1 MIPI DPhy Decoder 1.0 General: The MIPI DPhy Decoder (DPhyDkd) is the hardware probe that supports protocol

More information

TDSHT3 HDMI Compliance Test Software Programmer Online Help

TDSHT3 HDMI Compliance Test Software Programmer Online Help xx ZZZ TDSHT3 HDMI Compliance Test Software Programmer Online Help *P077035301* 077-0353-01 ZZZ TDSHT3 HDMI Compliance Test Software Programmer Online Help www.tektronix.com 077-0353-01 Copyright Tektronix.

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

Quick Reference Guide WaveRunner Xi-A and MXi-A Oscilloscopes

Quick Reference Guide WaveRunner Xi-A and MXi-A Oscilloscopes Quick Reference Guide WaveRunner Xi-A and MXi-A Oscilloscopes To get started quickly, take a few moments to read through this guide. Additional information can be found in the Getting Started Manual. On-line

More information

Solving MIPI D-PHY Receiver Test Challenges

Solving MIPI D-PHY Receiver Test Challenges Stefan Walther and Yu Hu Verigy stefan.walther@verigy.com yu.hu@verigy.com Abstract MIPI stands for the Mobile Industry Processor Interface, which provides a flexible, low-cost, high-speed interface solution

More information

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 Thank you for purchasing TOA s Digital Speaker Processor. Please carefully follow the instructions in this manual to ensure long, trouble-free use

More information

HP Video Over Ethernet. User Guide

HP Video Over Ethernet. User Guide HP Video Over Ethernet User Guide 2016 HP Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth

More information

TBS2000 Oscilloscope Demo Guide 28 JULY 2016

TBS2000 Oscilloscope Demo Guide 28 JULY 2016 TBS2000 Oscilloscope Demo Guide 28 JULY 2016 Table of Contents TBS2000 Series Oscilloscopes About This Guide & Required Equipment Setting up the Equipment Front Panel Tour Understanding the Display 1.

More information

User Guide 701P Wide Format Solution Wide Format Scan Service

User Guide 701P Wide Format Solution Wide Format Scan Service User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.

More information

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence WaveAce Oscilloscopes 40 MHz 200 MHz Debug With Confidence THE TOOLS AND FEATURES FOR ALL YOUR DEBUG NEEDS Key Features 40 MHz, 60 MHz, 100 MHz, and 200 MHz bandwidths Sample rates up to 2 GS/s Long Waveform

More information

Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or Series Oscilloscopes

Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or Series Oscilloscopes Agilent Technologies N5393A PCI Express Electrical Performance Validation and Compliance Software for Infiniium 54855A or 80000 Series Oscilloscopes Data Sheet Verify and debug your PCI Express designs

More information

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance the PCI EXPRESS 2.0 Super Highway Towards Full Compliance Page 1 Agenda Introduction PCIe 2.0 changes from 1.0a/1.1 Spec 5GT/s Challenges Error Correction Techniques Test tool and fixture changes Agilent

More information

Agilent Technologies 16700B-Series Logic Analysis Systems. Installation Guide. Publication number November 2002

Agilent Technologies 16700B-Series Logic Analysis Systems. Installation Guide. Publication number November 2002 Installation Guide Publication number 16700-97023 November 2002 For Safety information and Regulatory information, see the pages behind the index. Copyright Agilent Technologies 2000-2002 All Rights Reserved

More information

NBASE-T and IEEE802.3bz Ethernet Testing 7 MARCH 2016

NBASE-T and IEEE802.3bz Ethernet Testing 7 MARCH 2016 NBASE-T and IEEE802.3bz Ethernet Testing Agenda Market Drivers for 2.5G/5G Ethernet Data Rates 2.5G/5G Ethernet Transmitter Test Challenges and Solutions Testing Approach for 2.5G/5G Data Rates Information/Resources

More information

P338 Dual 4-lane MIPI DPhy Probe Data Sheet & User Manual. October Rev 1.1

P338 Dual 4-lane MIPI DPhy Probe Data Sheet & User Manual. October Rev 1.1 P338 Dual 4-lane MIPI DPhy Probe Data Sheet & User Manual October 2012 - Rev 1.1 PG3A Pattern Generator P338 MIPI D-PHY Probe 1.0 General: The P338 probe features 2 links each comprising 4 data lanes and

More information

PCI-express data acquisition card DAQ0504M User Guide

PCI-express data acquisition card DAQ0504M User Guide PCI-express data acquisition card DAQ0504M User Guide Contents Safety information... 3 About this guide... 4 DAQ0504M specifications... 5 Chapter 1. Product introduction 1-1. Package contents...... 6.

More information

Avalanche Remote Control User Guide. Version 4.1

Avalanche Remote Control User Guide. Version 4.1 Avalanche Remote Control User Guide Version 4.1 ii Copyright 2012 by Wavelink Corporation. All rights reserved. Wavelink Corporation 10808 South River Front Parkway, Suite 200 South Jordan, Utah 84095

More information

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition January 2015 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result

More information

DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual. February Rev 1.2

DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual. February Rev 1.2 DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual February 2012 - Rev 1.2 1 MIPI DPhy Preprocessor 1.0 General: The MIPI DPhy Preprocessor (DPhyPre) is the hardware probe

More information

ControlMaster controllers and indicators ConfigPilot

ControlMaster controllers and indicators ConfigPilot ABB MEASUREMENT & ANALYTICS INSTRUCTION ControlMaster controllers and indicators ConfigPilot Creating, uploading and downloading configurations Measurement made easy 1 Introduction A configuration for

More information

U4431 MIPI M-PHY Protocol Analyzer. User Guide

U4431 MIPI M-PHY Protocol Analyzer. User Guide U4431 MIPI M-PHY Protocol Analyzer User Guide Notices Agilent Technologies, Inc. 2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

Universal Serial Bus Implementers Forum Host High-speed Electrical Test Procedure for LeCroy

Universal Serial Bus Implementers Forum Host High-speed Electrical Test Procedure for LeCroy Universal Serial Bus Implementers Forum Host High-speed Electrical Test Procedure for LeCroy Revision 1.0 Dec. 3, 2003 1 Revision History Rev Date Filename Comments 0.9 (Beta) May-23-2003 Host HS Test

More information

90000 DSO/DSA Series Oscilloscopes

90000 DSO/DSA Series Oscilloscopes DDR4 Keysight Compliance Infiniium Test Bench 90000 DSO/DSA Series Oscilloscopes ADS DDR4 DesignGuide and Compliance Test Bench 1 Contents Installing the DDR4 Compliance Test Bench... 2 Prerequisites...

More information

VERUS Navigation Guide

VERUS Navigation Guide VERUS Navigation Guide diagnostics.snapon.com Contents Chapter 1: Getting Started... 3 Powering Up... 3 Module Buttons... 4 VERUS Toolbar... 5 Powering Down... 5 Emergency Shutdown... 5 Chapter 2: Scanner...

More information

GFT6084 Quad 2 / 4GS Digitizer

GFT6084 Quad 2 / 4GS Digitizer FEATURES 2U, 19 Compact form factor 4 analog channels with vertical sensitivity 1mV/div to 10V/div Up to 2GS/s sampling rate per channel or 4 GS/s sampling rate on 2 channels DC to 500MHz Analog Bandwidth,

More information

Automotive Ethernet BroadR-Reach

Automotive Ethernet BroadR-Reach Automotive Ethernet BroadR-Reach Agilent PHY Compliance Solutions 1 Last update 2013/07/25 (YS) Agenda BroadR-Reach Overview Transmitter Testing Link Segment Testing 2 BroadR-Reach Applications 3 Connectivity

More information

TekExpress 400G-TXE Electrical Compliance Solution for Real Time Oscilloscopes Printable Application Help

TekExpress 400G-TXE Electrical Compliance Solution for Real Time Oscilloscopes Printable Application Help TekExpress 400G-TXE Electrical Compliance Solution for Real Time Oscilloscopes Printable Application Help *P077136600* 077-1366-00 TekExpress 400G-TXE Electrical Compliance Solution for Real Time Oscilloscopes

More information

InfiniBand Trade Association

InfiniBand Trade Association InfiniBand Trade Association Revision 1.06 4/11/2017 IBTA VNA MOI for FDR and EDR Cable Tests This material is provided for reference only. The InfiniBand Trade Association does not endorse the vendors

More information

Configuration Guide for Microsoft Internet Connection Sharing

Configuration Guide for Microsoft Internet Connection Sharing Configuration Guide for Microsoft Internet Connection Sharing HUB INTERNET HOST CLIENTS Copyright 2002 Hughes Network Systems, Inc., a wholly owned subsidiary of Hughes Electronics Corporation. All rights

More information

Serial ATA International Organization

Serial ATA International Organization Serial ATA International Organization Revision 1.00RC2 22-June 2006 Serial ATA Interoperability Program Agilent Technologies, Inc. Method of Implementation (MOI) Document for SATA PHY, TSG & OOB Measurements

More information

PMS 138 C Moto Black spine width spine width 100% 100%

PMS 138 C Moto Black spine width spine width 100% 100% Series MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners. 2009 Motorola, Inc. Table of

More information

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500 CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide CyberScan DO 1500 Bench Dissolved Oxygen Meter Technology Made Easy... 68X292341 Rev.0 01/04 PREFACE Thank you for selecting the CyberScan

More information

Workbench V Integrated Development Environment for Renesas Capacitive Touch

Workbench V Integrated Development Environment for Renesas Capacitive Touch User s Manual Workbench V1.06.00 Integrated Development Environment for Renesas Capacitive Touch Target Device RX Family User s Manual All information contained in these materials, including products and

More information

QUICK START. DevCom2000 User Manual

QUICK START. DevCom2000 User Manual QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

Raj Kumar Nagpal, R&D Manager Synopsys. Enabling Higher Data Rates and Variety of Channels with MIPI D-PHY

Raj Kumar Nagpal, R&D Manager Synopsys. Enabling Higher Data Rates and Variety of Channels with MIPI D-PHY Raj Kumar Nagpal, R&D Manager Enabling Higher Data Rates and Variety of Channels with MIPI D-PHY Agenda Design motivation MIPI D-PHY evolution Summary of MIPI D-PHY specification MIPI channel evolution

More information

Agilent N5393B PCI Express Automated Test Application

Agilent N5393B PCI Express Automated Test Application Agilent N5393B PCI Express Automated Test Application Compliance Testing Methods of Implementation Agilent Technologies Notices Agilent Technologies, Inc. 2004-2009 No part of this manual may be reproduced

More information

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence WaveAce Oscilloscopes 40 MHz 300 MHz Debug With Confidence the tools and features for all your debug the tools and features for all your debug needs needs Key Features 40 MHz, 60 MHz, 100 MHz, 200 MHz

More information

Ansur ProSim 6/8. Users Manual. Software Plug-In

Ansur ProSim 6/8. Users Manual. Software Plug-In Ansur ProSim 6/8 Software Plug-In Users Manual FBC-0002 April 2011, Rev. 2, 8/11 2011 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Table of Contents

More information

SFF-8431 SFP+ Technology

SFF-8431 SFP+ Technology SFF-8431 SFP+ Technology Agenda Tektronix Ethernet Solution Background Information SFP-TX SFP+ Automation and Debug Solution Questions and open discussion 2 Tektronix Ethernet Solution Background Information

More information

Axon HD Content Management Application (CMA)

Axon HD Content Management Application (CMA) [ ] Axon HD Content Management Application (CMA) A Content Management Application (CMA) running on an Axon HD media server or a computer connected through an Ethernet network gives you remote control of

More information

Content Management Application (CMA)

Content Management Application (CMA) Chapter 13: CHAPTER 13 A running on an Axon HD media server or a computer connected through an Ethernet network gives you remote control of content, software and configuration management functions. The

More information

User Guide 980 HDMI Protocol Analyzer Module HDMI & MHL Source Compliance Tests NEED TO UPDATE FOR MHL TEST RESULTS

User Guide 980 HDMI Protocol Analyzer Module HDMI & MHL Source Compliance Tests NEED TO UPDATE FOR MHL TEST RESULTS User Guide 980 HDMI Protocol Analyzer Module HDMI & MHL Source Compliance Tests NEED TO UPDATE FOR MHL TEST RESULTS Rev: A4 Page 1 August 5, 2013 Table of Contents 1 About the 980 HDMI Protocol Analyzer

More information

U4421A MIPI D-PHY (CSI-2/DSI) Protocol Exerciser and Analyzer. Bring your CSI-2 and DSI-1 designs to market faster with complete confidence

U4421A MIPI D-PHY (CSI-2/DSI) Protocol Exerciser and Analyzer. Bring your CSI-2 and DSI-1 designs to market faster with complete confidence U4421A MIPI D-PHY (CSI-2/DSI) Protocol Exerciser and Analyzer Bring your CSI-2 and DSI-1 designs to market faster with complete confidence Agilent s MIPI Solutions Application Protocol Standard CSI-2 camera

More information

PCI Express (Rev1.1) Test Methodologies Data Signal Quality; Reference Clock Jitter

PCI Express (Rev1.1) Test Methodologies Data Signal Quality; Reference Clock Jitter PCI Express (Rev1.1) Test Methodologies Data Signal Quality; Reference Clock Jitter Users Guide for: Tektronix Real Time Oscilloscopes (DSA/DPO70000 Series, TDS6000B/C Series, or TDS7704B) September 2006

More information

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes N5395B Ethernet Electrical Conformance Test Fixture N5396A Gigabit Ethernet Jitter

More information

Universal Serial Bus 2.0 Host Compliance Test Procedure

Universal Serial Bus 2.0 Host Compliance Test Procedure Universal Serial Bus 2.0 Host Compliance Test Procedure 2nd Edition Introduction Purpose Trademarks Revisions The USB-IF Hi-Speed Electrical Test Procedures are developed by the USB 2.0 Compliance Committee

More information

AT&T Core Mobility Integrated Dispatch Console User Guide. Installation Guide. AT&T Integrated Dispatch Console 3.0

AT&T Core Mobility Integrated Dispatch Console User Guide. Installation Guide. AT&T Integrated Dispatch Console 3.0 Installation Guide AT&T Integrated Dispatch Console 3.0 October 2016 Table of Content 1. Introduction... 3 1.1. Purpose and Scope... 3 1.2. Terms and Definitions... 3 1.3. About this Manual... 5 1.4. What

More information

HDMI Electrical, Protocol Audio Video ( PAV ) and Content Protection, HDCP

HDMI Electrical, Protocol Audio Video ( PAV ) and Content Protection, HDCP HDMI Electrical, Protocol Audio Video ( PAV ) and Content Protection, HDCP Application of ZX200 ZX201 ZX201L HDMI electrical testing Zebax offers high quality HDMI breakout adapters ( aka test boards )

More information

DisplayPort Testing Challenges

DisplayPort Testing Challenges DisplayPort Testing Challenges U N Vasudev May 6 th 2013 Agenda DisplayPort Overview DisplayPort 1.2 updates DisplayPort 1.2 Transmitter Testing What s New: T2, TP3, TP3EQ Physical Layer Test Overview

More information

A Division of Cisco Systems, Inc. Dual-Band. Wireless A/G g a. User Guide. Game Adapter WIRELESS WGA54AG (EU/LA/UK) Model No.

A Division of Cisco Systems, Inc. Dual-Band. Wireless A/G g a. User Guide. Game Adapter WIRELESS WGA54AG (EU/LA/UK) Model No. A Division of Cisco Systems, Inc. Dual-Band 5GHz 2, 4GHz 802.11a 802.11g WIRELESS Wireless A/G Game Adapter User Guide Model No. WGA54AG (EU/LA/UK) Copyright and Trademarks Specifications are subject to

More information

Avigilon Control Center Server User Guide

Avigilon Control Center Server User Guide Avigilon Control Center Server User Guide Version 4.12 PDF-SERVER-E-Rev1 Copyright 2012 Avigilon. All rights reserved. The information presented is subject to change without notice. No copying, distribution,

More information

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version 3.70.1.0 These Release Notes are for following models of the R&S RTO and R&S RTE: R&S RTO 2002, order no. 1329.7002K02, R&S RTO 2004, order

More information

USB 3.0 Receiver Compliance Testing

USB 3.0 Receiver Compliance Testing USB 3.0 Receiver Compliance Testing Methods of Implementation Using Tektronix BERTScope BSA85C Analyzer, CR125A Clock Recovery, DPP125B Digital De-Emphasis Processor, Instrument Switch, and DSA/DSO/MSO71254B

More information

PCmover Enterprise Policy Manager User Guide

PCmover Enterprise Policy Manager User Guide Laplink Software, Inc. PCmover Enterprise Policy Manager User Guide The Only Software that Moves Programs, Files, and Settings to a New PC! MN-PCMVENTPR-8-EN (REV. 2/26/2015) Laplink Software, Inc. For

More information

9936A LogWare III. User s Guide. Revision

9936A LogWare III. User s Guide. Revision 9936A LogWare III User s Guide Revision 850701 Table of Contents 1 Introduction...1 1.1 Symbols Used... 1 1.2 Conventions... 1 1.3 What is LogWare?... 1 1.4 License Agreement... 2 1.5 Requirements...

More information

The following steps will allow you to install and quickly begin using DevCom2000:

The following steps will allow you to install and quickly begin using DevCom2000: QUICK START DevCom2000 uses Device Descriptions (DDs) to access data stored in the memory of the smart field device. These DDs are developed by the manufacturer for their products and, in turn, distributed

More information

AUTOMATOR REFERENCE MANUAL

AUTOMATOR REFERENCE MANUAL AUTOMATOR REFERENCE MANUAL Improvision, Viscount Centre II, University of Warwick Science Park, Millburn Hill Road, Coventry, CV4 7HS Tel: +44 (0) 24 7669 2229 Fax: +44 (0) 24 7669 0091 e-mail: admin@improvision.com

More information

hp l1619a smart attachment module

hp l1619a smart attachment module hp l1619a smart attachment module user s guide Smart Attachment Module 1 Notice This manual and any examples contained herein are provided as is and are subject to change without notice. Hewlett-Packard

More information

To upgrade to the i-vu v6.0 application

To upgrade to the i-vu v6.0 application i-vu Application Upgrade Guide to v6.0 CARRIER CORPORATION 2014 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-493-01 3/21/2014 Table of Contents To upgrade

More information

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup Lab 6 EasyScope Remote Control (30 Minutes) Note:(Screenshots below show a white background configuration of your WaveAce to save black ink in printing, this configuration is explained in Lab 2 VIEW) Overview

More information

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes N5395B Ethernet Electrical Conformance Test Fixture N5396A Gigabit Ethernet Jitter

More information

WaveAce Series Oscilloscopes

WaveAce Series Oscilloscopes WaveAce Series Oscilloscopes 60 MHz 300 MHz Debug With Confidence THE TOOLS AND FEATURES FOR ALL YOUR DEBUG NEEDS Key Features 60 MHz, 100 MHz, 200 MHz and 300 MHz bandwidths Sample rates up to 2 GS/s

More information

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151 USER S MANUAL Contents 1. Main Features... 4 A Variety of Display Formats...4 Simple and Easy to Use...5 Thumbnail Waveform Display...5 Export to Direct Excel File Function...6 CSV File Batch Conversion...6

More information

Agilent Technologies EZJIT and EZJIT Plus Jitter Analysis Software for Infiniium Series Oscilloscopes

Agilent Technologies EZJIT and EZJIT Plus Jitter Analysis Software for Infiniium Series Oscilloscopes Agilent Technologies EZJIT and EZJIT Plus Jitter Analysis Software for Infiniium Series Oscilloscopes Data Sheet Features of the EZJIT Plus software that optimize jitter analysis include: Easy-to-use jitter

More information