1 Installation Instructions Line Interface Module Catalog Numbers 09-ALS, 09-ALS, 09-AL0S, 09-AL7S, 09-BL0S, 09-BLS, 09-BL0S, 09-BL7S, 09-XL7S-C, 09-XL7S-C, 09-AL09, 09-BL0 Topic Page About the Line Interface Module Important User Information Catalog Number Explanation Before You Begin Connector Data 9 Understanding Signal Specifications 7 Install the Line Interface Module 7 Wiring Diagrams Block Diagrams Post-installation 0 Status Indicators Specifications Additional Resources 6 About the Line Interface Module The Bulletin 09 line interface module is designed to replace many of the common-input power devices required for your servo drive system. Use these instructions when mounting your module to the panel or wiring your module into the system. For installation information regarding equipment and accessories excluded here, see Additional Resources on page 6 or the information available for those products.

2 Line Interface Module Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Labels may also be on or inside the equipment to provide specific precautions. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE). Rockwell Automation Publication 09-IN00I-EN-P - June 0

3 Line Interface Module Catalog Number Explanation Catalog numbers and descriptions for the line interface module are listed in the table below. Cat. No. Input Voltage Current Rating Description 09-ALS A 09-ALS A 0V 09-AL0S 0 A 0V AC auxiliary power output. Customer-configurable branch-circuit V DC power output with 0 A current capacity. 09-AL7S 7 A protection. This feature provides the Branch circuit protection and disconnect when used with the option for connecting CB and CB before variable-depth rotary mechanism (catalog number 09-BL0S 0 A or after the main (CB) disconnect. 0G-G-RVMB). See Configure Branch-circuit Protection on 09-BLS A Power to multiple Bulletin 09 or 09 power rails. 60V page 0 for more information. Internal V DC I/O line filter. 09-BL0S 0 A Internal 0V AC control line filter. External (customer supplied) -phase line filter. 09-BL7S 7 A 09-XL7S-C 0/60V 7 A 0V AC auxiliary power input. 09-XL7S-C 0/60V 7 A 0V AC auxiliary power input. 09-AL09 0V 0 A V DC power output with 8 A current capacity. 09-BL0 60V 0 A Internal -phase line filter. Internal 0V AC control line filter. Before You Begin Before you begin mounting your line interface module, make sure you: unpack your line interface module. understand the mounting requirements. establish noise zones. Unpack Your Line Interface Module Remove all packing material, wedges, and braces from within and around the components. After unpacking, check the item nameplate catalog number against the purchase order. Line interface modules ship with the following items: Connector set for 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx line interface modules includes I/O (IOL), VAC line (IPL), VAC load (OPL), control power (CPL), V brake/io power (PL), auxiliary 0V Output (PL), and auxiliary 0V input (APL) connectors. Connector set for 09-AL09 and 09-BL0 line interface modules includes VAC line (IPL), VAC load (OPL), control power (CPL), and V brake I/O power (PSL) connectors. The I/O (6-pin) connector for 09-AL09 and 09-BL0 line interface modules is not provided. See Accessories on page for the catalog number and a complete description of the connector sets. These installation instructions, publication 09-IN00. Rockwell Automation Publication 09-IN00I-EN-P - June 0

4 Line Interface Module Mounting Requirements ATTENTION: Plan the installation of your system so that you can perform all cutting, drilling, tapping, and welding with the system removed from the enclosure. Because the system is of the open type construction, be careful to keep any metal debris from falling into it. Metal debris or other foreign matter can become lodged in the circuitry, which can result in damage to components. The following requirements apply when preparing to mount your line interface module: The line interface module must be enclosed in a grounded conductive enclosure offering protection as defined in standard EN 609 (IEC 9) to IP such that they are not accessible to an operator or unskilled person, to comply with UL and CE requirements. A NEMA X enclosure exceeds these requirements providing protection to IP66. The panel you install inside the enclosure for mounting your system components must be on a flat, rigid, vertical surface that won t be subjected to shock, vibration, moisture, oil mist, dust, or corrosive vapors. Observe the Environmental Specifications on page. Maintain minimum clearances for proper airflow, easy module access, and proper cable bend radius as shown in the figures on page. IMPORTANT Mount the line interface module in an upright position as shown. Do not mount the module on its side. Rockwell Automation Publication 09-IN00I-EN-P - June 0

5 Line Interface Module Figure - Minimum Clearance Requirements (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) Clearance for Airflow and Installation 0.8 mm (.0 in.) min Line Interface Module (catalog number 09-ALxxS is shown) Clearance left of module is not required. Clearance right of module is not required. Clearance for Airflow and Installation 0.8 mm (.0 in.) min Figure - Minimum Clearance Requirements (catalog numbers 09-AL09 and 09-BL0) Clearance for Airflow and Installation 0.8 mm (.0 in.) min Line Interface Module (catalog number 09-BL0 is shown) Clearance for Airflow and Installation 0.8 mm (.0 in.) min Clearance for Airflow and Installation 0.8 mm (.0 in.) min Clearance for Airflow and Installation 0.8 mm (.0 in.) min Cat. No. 09-ALxxS 09-XL7S 09-BLxxS 09-AL09 09-BL0 Cabinet Depth Clearance, min 00 mm (7.9 in.) 0 mm (9.8 in.) 00 mm (7.9 in.) 00 mm (.8 in.) For Power Dissipation Specifications, see page. Rockwell Automation Publication 09-IN00I-EN-P - June 0

6 6 Line Interface Module Establishing Noise Zones Observe these guidelines when a 09-ALxxS, 09-BLxxS, or 09-XL7S-Cx line interface module is used in the system and mounted left of the drive with the AC (EMC) line filter mounted above the module: The clean zone (C) is to the right and beneath the drive system (gray wireway). The dirty zone (D) is to the left and above the drive system, and above and below the line interface module (black wireway). The very dirty zone (VD) is from the filter output to drive. Shielded cable is required on the EMC filter (LOAD side) and the braided shield attached to the clamp (when provided). The sercos fiber-optic cables are immune to electrical noise. Figure - Establishing Noise Zones (EMC filter above the line interface module) Dirty Wireway Clean Wireway D AC Line Filter VD Motor Power Cables VAC LOAD Very dirty Filter/Drive connections segregated (not in wireway) D D D VAC LINE D D VD No sensitive equipment within 0 mm (6.0 in.) () Drive/ System Module () D Line Interface Module (catalog number 09-ALxxS is shown) D C I/O () and Feedback Cables Route V DC I/O Shielded Cable Route Encoder/Analog/Registration Shielded Cables () If drive system I/O cable contains (dirty) relay wires, route cable with module I/O cable in dirty wireway. () When space does not permit the 0 mm (6.0 in.) segregation, use a grounded steel shield instead. For examples, see the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM00. () The Kinetix 6000 drive is shown as an example of any drive or other device in configuration with the line interface module; however, noise zones of other products will vary. Rockwell Automation Publication 09-IN00I-EN-P - June 0

7 Line Interface Module 7 Observe these guidelines when a 09-ALxxS, 09-BLxxS, or 09-XL7S-Cx line interface module is used in the system and mounted right of the drive with the AC (EMC) line filter mounted behind the line interface module: The clean zone (C) is to the left and beneath the drive system (gray wireway). The dirty zone (D) is to the right and above the drive, and above and below the line interface module (black wireway). The very dirty zone (VD) is from the filter output to drive. Shielded cable is required on the EMC filter (LOAD side) and the braided shield attached to the clamp (when provided). The sercos fiber-optic cables are immune to electrical noise. Figure - Establishing Noise Zones (EMC filter behind the line interface module) Clean Wireway Dirty Wireway Motor Power Cables D Very dirty Filter/Drive connections segregated (not in wireway) D D D VAC LINE VAC LOAD Control VAC Auxiliary VAC V DC Brake VD PR No sensitive equipment within 0 mm (6.0 in.) () VD D LIM I/O Drive/System Module () AC (EMC) Line Filter PR C I/O () and Feedback Cables C Line Interface Module (catalog number 09-ALxxS is shown) 09 Mounting Brackets () x D Route Encoder/Analog/Registration Shielded Cables Route V DC I/O Shielded Cable () If the drive system I/O cable contains (dirty) relay wires, route cable with the module I/O cable in dirty wireway. () When space does not permit the 0 mm (6.0 in.) segregation, use a grounded steel shield instead. For examples, see the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM00. () The Kinetix 6000 drive is shown as an example of any drive or other device in configuration with the line interface module; however, noise zones of other products will vary. () Only the 09-ALxxS and 09-XL7S-Cx line interface modules are compatible with 09 mounting brackets. The 09-BLxxS, 09-AL09, and 09-BL0 line interface modules are not compatible. Rockwell Automation Publication 09-IN00I-EN-P - June 0

8 8 Line Interface Module Observe these guidelines when a 09-AL09 or 09-BL0 line interface module is used in the drive system: The clean zone (C) is to the right and beneath the drive system (gray wireway). The dirty zone (D) is to the left and above the drive, and above and below the line interface module (black wireway). The very dirty zone (VD) is limited to where the line interface module VAC output jumpers over to the drive. Shielded cable is required only if the very dirty cables enter a wireway. The sercos fiber-optic cables are immune to electrical noise. Figure - Establishing Noise Zones (catalog numbers 09-AL09 or 09-BL0) Dirty Wireway D Very dirty LIM/Drive connections segregated (not in wireway) Motor Power Cables Clean Wireway D VD D No sensitive equipment within 0 mm (6.0 in.) () D Line Interface Module (catalog number 09-AL09 is shown) D C C Drive/ System Module () I/O () and Feedback Cables Route V DC I/O Shielded Cable Route Encoder/Analog/Registration Shielded Cables () If drive system I/O cable contains (dirty) relay wires, route cable with module I/O cable in dirty wireway. () When space does not permit the 0 mm (6.0 in.) segregation, use a grounded steel shield instead. For examples, see the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM00. () The Kinetix 6000 drive is shown as an example of any drive or other device in configuration with the line interface module; however, noise zones of other products will vary. Rockwell Automation Publication 09-IN00I-EN-P - June 0

9 Line Interface Module 9 Connector Data Use the figures below to locate the line interface module connectors and indicators. Figure 6 - Connectors and Indicators (catalog numbers 09-ALxxS, 09-BL7xxS, and 09-XL7S-Cx) Auxiliary Power Input (APL) Connector () VAC Line (IPL) Connector VAC Load (OPL) Connector L/N 9-6 VAC LOAD, 0/60 Hz 9-6 VAC LINE, 0/60 Hz L L L L L' L' L' CTRL CTRL AUX AUX AUX AUX I/O_COM I/O_PWR I/O_COM I/O_PWR I/O_COM I/O_PWR 6 CONTROL VAC 0 VAC SUPPLY VDC SUPPLY Control Power Output (CPL) Connector Auxiliary Power Output (PL) Connector V DC Brake Power Output (PL) Connector Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) I/O (IOL) Connector Access Door V Power Status Indicator Main VAC I/O (IOL) Connector (staggered) IOL Connector (as viewed from side) CB FB CB Brake-I/O VAC Fuse Block Control/AUX VAC Line Interface Module, Front View (catalog number 09-XL7S-Cx is shown) I/O (IOL) Connector (straight) IOL Connector (as viewed from side) () Auxiliary Power Input (APL) connector is present only on the 09-XL7S-Cx line interface module. Rockwell Automation Publication 09-IN00I-EN-P - June 0

10 0 Line Interface Module Figure 7 - Connectors and Indicators (catalog numbers 09-AL09 and 09-BL0) Line Interface Module, Top View (catalog number 09-AL09 is shown) VAC Line (IPL) Connector 9-6 VAC LINE 0/60 Hz PE L L L MBRK PWR MBRK COM MBRK PWR MBRK COM VDC BRAKE SUPPLY L L/N PE L L L 0 VAC LOAD 9-6 VAC LOAD 0/60 Hz Control Power Output (CPL) Connector VAC Load (OPL) Connector V DC Brake Power Output (PSL) Connector Line Interface Module, Front View (catalog number 09-AL09 is shown) Brake Power Status Indicator MAIN VAC AUX VAC BRAKE - I/O VAC I/O Power Status Indicator CB CB CB Line Interface Module 09-AL09 00/0V AC 0A Output I/O (IOL) Connector Main VAC Control/AUX VAC Brake-I/O VAC Rockwell Automation Publication 09-IN00I-EN-P - June 0

11 Line Interface Module Line Interface Module Connectors Table - Connectors (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) Designator Description Connector IOL Status I/O -pin (plugable) terminal block IPL VAC LINE input power -position plug/header OPL VAC LOAD output power -position plug/header PL Brake and I/O power output (V DC) 6-position plug/header PL Auxiliary power output (0V AC) -position plug/header CPL Control power output -position plug/header APL () Auxiliary power input -position plug/header () Auxiliary power input (APL) connector is present only on the 09-XL7S-Cx module. Table - Connectors (catalog numbers 09-AL09 and 09-BL0) Designator Description Connector IOL Status I/O 6-pin high-density D-shell IPL VAC LINE input power -position terminals OPL VAC LOAD output power -position terminals PSL Brake and I/O power output (V DC) -position plug/header CPL Control power output -position plug/header I/O Connector These tables provide signal descriptions and pinouts for the I/O (IOL) connector. Table - IOL (-pin) Connector Pinouts (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) IOL Pin Description Signal IOL Pin Description Signal IO V supply IO_PWR Alarm common (CB) ALRM_COM IO V common IO_COM Contactor auxiliary contact (NC) # IN CONSTAT_ IO V supply IO_PWR Contactor auxiliary contact (NC) # OUT CONSTAT_ IO V common IO_COM Contactor auxiliary contact (NC) # IN CONSTAT_ IO V supply IO_PWR 6 Contactor auxiliary contact (NC) # OUT CONSTAT_ 6 IO V common IO_COM 7 Contactor auxiliary contact (NC) # IN CONSTAT_ 7 V contactor coil positive COIL_E 8 Contactor auxiliary contact (NC) # OUT CONSTAT_ 8 V contactor coil negative COIL_E 9 Contactor auxiliary contact (NO) # IN CONSTAT_ 9 Alarm make contact (CB) ALRM_M 0 Contactor auxiliary contact (NO) # OUT CONSTAT_ 0 SHIELD SHIELD SHIELD SHIELD Alarm break contact (CB) ALRM_B Rockwell Automation Publication 09-IN00I-EN-P - June 0

12 Line Interface Module Your IOL connector terminals may be staggered, as in Figure 8, or straight, as in Figure 9. Figure 8 - Pin Orientation for the IOL (-pin) Connector, Staggered I/O (IOL) Connector Access Door (door open) IOL IO_PWR IO_COM IO_PWR IO_COM IO_PWR 6 IO_COM 7 COIL_E 8 COIL_E 9 ALRM_M 0 SHIELD ALRM_B ALRM_COM CONSTAT_ CONSTAT_ CONSTAT_ 6 CONSTAT_ 7 CONSTAT_ 8 CONSTAT_ 9 CONSTAT_ 0 CONSTAT_ SHIELD Line Interface Module (catalog number 09-ALxxS is shown) IOL IO_PWR IO_COM IO_PWR IO_COM IO_PWR IO_COM COIL_E COIL_E ALRM_M SHIELD ALRM_B ALRM_COM CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ SHIELD Pin Pin -pin I/O Staggered Pin (IOL) Connector Pin 0 Figure 9 - Pin Orientation for the IOL (-pin) Connector, Straight I/O (IOL) Connector Access Door (door open) IOL IO_PWR IO_COM IO_PWR IO_COM IO_PWR 6 IO_COM 7 COIL_E 8 COIL_E 9 ALRM_M 0 SHIELD ALRM_B ALRM_COM CONSTAT_ CONSTAT_ CONSTAT_ 6 CONSTAT_ 7 CONSTAT_ 8 CONSTAT_ 9 CONSTAT_ 0 CONSTAT_ SHIELD Line Interface Module (catalog number 09-ALxxS is shown) IOL IO_PWR IO_COM IO_PWR IO_COM IO_PWR IO_COM COIL_E COIL_E ALRM_M SHIELD ALRM_B ALRM_COM CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ SHIELD Pin Pin -pin I/O StraightPin (IOL) Connector Pin 0 Rockwell Automation Publication 09-IN00I-EN-P - June 0

13 Line Interface Module Table - IOL (6-pin) Connector Pinouts (catalog numbers 09-AL09 and 09-BL0) IOL Pin Description Signal IOL Pin Description Signal Reserved Reserved Reserved Contactor auxiliary contact (NC) # IN CONSTAT_ Reserved 6 Contactor auxiliary contact (NC) # IN CONSTAT_ V contactor coil negative COIL_A 7 Contactor auxiliary contact (NC) # IN CONSTAT_ Reserved 8 Contactor auxiliary contact (NC) # IN CONSTAT_ 6 Contactor auxiliary contact (NC) # OUT CONSTAT_ 9 Reserved 7 Contactor auxiliary contact (NC) # OUT CONSTAT_ 0 IO V common IO_COM 8 Contactor auxiliary contact (NC) # OUT CONSTAT_ IO V common IO_COM 9 Contactor auxiliary contact (NC) # OUT CONSTAT_ IO V common IO_COM 0 Reserved Reserved Reserved IO V supply IO_PWR Reserved IO V supply IO_PWR V contactor coil positive COIL_A 6 IO V supply IO_PWR Figure 0 - Pin Orientation for the IOL (6-pin) Connector 6-pin I/O Connector Pin 6 Pin 8 Pin 9 Pin 9 Pin 0 Pin Auxiliary Power Input Connector This table provides the signal descriptions and pinouts for the auxiliary power input (-pin) APL connector. This connector applies only to 09-XL7S-C and 09-XL7S-C line interface modules. APL Pin Description Signal L/N Auxiliary power input L Rockwell Automation Publication 09-IN00I-EN-P - June 0

14 Line Interface Module Control Power Output Connector These tables provide signal descriptions and pinouts for the control power (-pin) CPL connector. Table - CPL (-pin) Connector Pinouts (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) CPL Pin Description Signal CTRL Control power output CTRL Table 6 - CPL (-pin) Connector Pinouts (catalog numbers 09-AL09 and 09-BL0) CPL Pin Description Signal L Control power LOAD output L/N V DC Brake Supply Connector These tables provide signal descriptions and pinouts for the V brake supply connector, intended for use with mechanical motor brake or Bulletin 090 resistive-brake module (RBM) applications. Table 7 - PL (6-pin) Connector Pinouts (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) PL Pin Description Signal +V DC supply IO_PWR +V DC common IO_COM +V DC supply IO_PWR +V DC common IO_COM +V DC supply IO_PWR 6 +V DC common IO_COM Table 8 - PSL (-pin) Connector Pinouts (catalog numbers 09-AL09 and 09-BL0) PSL Pin Description Signal +V DC supply MBRK PWR +V DC common MBRK COM +V DC supply MBRK PWR +V DC common MBRK COM Rockwell Automation Publication 09-IN00I-EN-P - June 0

15 Line Interface Module VAC LINE Connector These tables provide signal descriptions and pinouts for the -phase input power (-pin) IPL connector. Table 9 - IPL (-pin) Connector Pinouts (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) IPL Pin Description Signal Chassis ground -phase input power L L Table 0 - IPL (-pin) Connector Pinouts (catalog numbers 09-AL09 and 09-BL0) IPL Pin 09-AL09 09-BL0 Description Signal Chassis ground PE L -phase input power L L L IMPORTANT ATTENTION: Make the chassis (earth) ground connection from a grounded configuration only. Rockwell Automation Publication 09-IN00I-EN-P - June 0

16 6 Line Interface Module VAC LOAD Connector These tables provide signal descriptions and pinouts for the -phase output power (-pin) OPL connector. Table - OPL (-pin) Connector Pinouts (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) OPL Pin Description Signal Chassis ground -phase output power L L Table - OPL (-pin) Connector Pinouts (catalog numbers 09-AL09 and 09-BL0) OPL Pin 09-AL09 09-BL0 Description Signal Chassis ground PE L -phase output power L L L Auxiliary Power Connector This table provides signal descriptions and pinouts for the auxiliary power output (-pin) PL connector. Table - PL (-pin) Connector Pinouts (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) Cat. No. PL Pin Description Signal 0V AC power supply. Can be used with the Bulletin 090-XB0 resistive-brake module AUX_L 09-ALxxS, (RBM) or other as needed. AUX_L 09-BLxxS, and 09-XL7S-C 0V AC power supply. Can be used with the AUX_L Bulletin 090-XB0 resistive-brake module (RBM) or other as needed. AUX_L 09-XL7S-C AUX_L 0V AC power supply. For use as needed. AUX_L AUX_L 0V AC power supply. For use as needed. AUX_L Rockwell Automation Publication 09-IN00I-EN-P - June 0

17 Line Interface Module 7 Understanding Signal Specifications A description of the I/O (IOL), brake power (PL/PSL), control power (CPL), and auxiliary power (PL) signals and circuit specifications is provided on the following pages. See the Block Diagrams beginning on page for your line interface modules schematic. IOL Pin Signal Description IOL-8 IOL-7 COIL_E COIL_E I/O Signals The 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx line interface module I/O (IOL) signals include the contactor coil, alarm contacts, status contacts, and I/O power supply. This table provides a description and electrical specifications for the IOL connector signals. See Power Specifications on page for auxiliary contactor specifications. Table - IOL (-pin) Signal Specifications (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) Line contactor coil connections with an auxiliary contact from the control power circuit breaker wired in series with the contactor coil. The line contactor is a safety contactor that includes three main contacts with three auxiliary contacts (see the figure on page 9). IOL- ALRM_COM Non-voltage contact (ALRM_M) to indicate that CB is closed (make) when CB is tripped. (DC) IOL-9 IOL- IOL- IOL- IOL-6 IOL- IOL-8 IOL-7 IOL-0 IOL-9 IOL- IOL- IOL-6 IOL- IOL- IOL- ALRM_M ALRM_B CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ IO_COM IO_PWR Non-voltage contact (ALRM_B) to indicate that CB is closed (make) when CB is not tripped. See the figure on page 8. (DC) Voltage (Volts) Current (Amps) Min Nom Max Min Nom Max [AC] 0 [AC] 600 Three safety-rated auxiliary contacts that are normally-closed on the line contactor (see the figure on page 0). One auxiliary contact (normally-open) that is not safety rated and should not be used in a safety string. Power supply capable of supplying 0 A for I/O functions and switches. Each set of pins is capable of 8 A. To use the full rating of the supply, all pins must be used to provide the appropriate current rating (see the figure on page ) Rockwell Automation Publication 09-IN00I-EN-P - June 0

18 8 Line Interface Module IOL- IOL- IOL-6 IOL- IOL-7 IOL-6 IOL-8 IOL-7 IOL-9 IOL-8 IOL-0 IOL- IOL- IOL- IOL- IOL-6 For more information regarding the Bulletin 00S-C8x- contactor, see the Safety Products Catalog, website The 09-AL09 and 09-BL0 line interface module I/O (IOL) signals include the contactor coil, status contacts, and I/O power supply. Table - IOL (6-pin) Signal Specifications (catalog numbers 09-AL09 and 09-BL0) IOL Pin Signal Description COIL_A COIL_A CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ IO_COM IO_PWR Line contactor coil connections with an auxiliary contact from the control power circuit breaker wired in series with the contactor coil. The line contactor is a safety contactor that includes three main contacts with four auxiliary contacts (see figure on page 9). Four pairs of auxiliary contacts that are normally-closed on the line contactor (see figure on page ). Power supply capable of supplying 6 A for I/O functions and switches. Each set of pins is capable of A. To use the full rating of the supply, all pins must be used to provide the appropriate current rating (see figure on page ). See Power Specifications beginning on page for auxiliary contactor specifications. CB Alarm Operation The CB alarm circuitry (ALRM_M contact) in the 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx line interface modules is closed only when CB trips (meaning input current exceeds instantaneous current trip setting) and not dependant on the ON/OFF switch. The ALRM_B contact is closed when CB is manually set to the ON or OFF position, and open when CB is tripped. Figure - CB Alarm Operation (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) OFF ON TRIP AL B M B M B M c c c Rockwell Automation Publication 09-IN00I-EN-P - June 0

19 Line Interface Module 9 Contactor Coil For safety reasons, the internal wiring is arranged so that if the control power (CPL) circuit breaker (CB) trips, the opening contact will interrupt the coil voltage and remove main input power to the drive. The 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx line interface modules use an AC coil and a DC interface module allows the contactor coil to be controlled by the V DC output of the drive. Additional surge suppression is not required for these contactors. IMPORTANT ATTENTION: Do not apply AC voltage to COIL_E and COIL_E. Figure - IOL Contactor Coil (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) Line Interface Module CB_AUX A CR A DC Interface Module E A E IOL-7 IOL-8 COIL_E COIL_E FB CB The contactors in the 09-AL09 and 09-BL0 line interface modules use a DC coil. The contactor coil voltage is V DC with a suitably-rated surge suppressor fitted inside the line interface module. Figure - IOL Contactor Coil (catalog numbers 09-AL09 and 09-BL0) COIL_A CR IOL- CB_AUX A A IOL- COIL_A CB 6 D Line Interface Module Rockwell Automation Publication 09-IN00I-EN-P - June 0

20 0 Line Interface Module Safety Contactor The safety contactor includes three main contacts (normally-open) that close when coil power is applied. The three auxiliary (safety) contacts (used in 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx line interface modules) are volt-free, positively-guided, and mechanically-latched. IMPORTANT A fourth volt-free normally-open contact is also available, but is not safety rated and should not be used in a safety string. Figure - IOL Contactor Status (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) CR 6 CONSTAT_ IOL- IOL- CONSTAT_ CONSTAT_ IOL- IOL-6 CONSTAT_ CONSTAT_ IOL-7 IOL-8 CONSTAT_ CONSTAT_ IOL-9 IOL-0 CONSTAT_ A A Line Interface Module See Power Specifications on page for auxiliary contactor specifications. Rockwell Automation Publication 09-IN00I-EN-P - June 0

21 Line Interface Module The four auxiliary (safety) contacts (used in 09-AL09 and 09-BL0 line interface modules) are volt-free, positively-guided, and mechanically-latched. Figure - IOL Contactor Status (catalog numbers 09-AL09 and 09-BL0) CR 6 CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ IOL- IOL-6 IOL-7 IOL-8 IOL-6 IOL-7 IOL-8 IOL-9 CONSTAT_ CONSTAT_ CONSTAT_ CONSTAT_ A A Line Interface Module See Power Specifications beginning on page for auxiliary contactor specifications. V Power Supply (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) The V DC power supply on 09-ALxxS, 09-BLxxS, and 09-XL7S-C line interface modules is capable of supplying 0 A for PLC I/O functions (IOL connector), mechanical motor brakes, and the Bulletin 090 resistive-brake module (RBM) I/O (PL connector). An AC line filter is placed on the input to the supply to provide conditioning. The supply is protected by circuit breaker CB. PLC I/O power is available to the user via the IOL (-pin) terminal block connector (as shown in the figure on page ). Motor brakes and the resistive-brake module I/O power is available to the user via the PL (6-pin) connector. Each PL output contains an LC circuit to prevent electrical noise contamination of the V supply and an MOV to prevent current surges from the motor brake. IMPORTANT Use the PL +V DC supply with devices that can potentially generate flyback currents (for example, brake coils and relays). Rockwell Automation Publication 09-IN00I-EN-P - June 0

22 Line Interface Module Figure 6 - IOL Power Supply (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) CB AC Line Filter L L PS 80 W, 0 A Power Supply V+ PE V- Line Interface Module IOL- IOL- IOL- IOL- IOL- IOL-6 IO_PWR IO_COM PL- PL- PL- IO_PWR PL- PL- PL-6 IO_COM Interface PCB IMPORTANT Each set of pins (IO_PWR and IO_PWR) is rated at 8 A (not to exceed 0 A for combined IOL and PL use). Rockwell Automation Publication 09-IN00I-EN-P - June 0

23 Line Interface Module I/O Power Supply (catalog numbers 09-AL09 and 09-BL0) The I/O power supply on 09-AL09 and 09-BL0 line interface modules is capable of supplying A for PLC I/O functions and switches. It is available to the user via the IOL (6-pin) D-sub connector. A single-phase filter is placed on the input to the supply to provide conditioning. The supply is protected by circuit breaker CB. ATTENTION: When current draw exceeds A (IOL-, IOL-, or IOL-6), multiple pins must be used to provide appropriate current rating and avoid connector damage. Figure 7 - IOL Power Supply (catalog numbers 09-AL09 and 09-BL0) AC Line Filter CB PS 0 W, 6 A Power Supply Line Interface Module IOL-6 IOL- IOL- IOL-0 IOL- IOL- IO_PWR IO_COM Rockwell Automation Publication 09-IN00I-EN-P - June 0

24 Line Interface Module Brake Power Supply (catalog numbers 09-AL09 and 09-BL0) A +V DC supply is provided on the PSL connector of the 09-AL09 and 09-BL0 line interface modules for mechanical motor brakes and the Bulletin 090 resistive-brake module I/O. The supply has over-current protection and is isolated from all other supplies. A single-phase filter placed on the input to the supply provides conditioning. The supply is protected by circuit breaker CB. The PSL brake power supply is rated at A. If more current is required, consider using the IOL power supply. IMPORTANT Use the PSL +V DC supply with devices that can potentially generate flyback currents (for example, brake coils and relays). This supply requires external flyback protection with either a diode or MOV. Figure 8 - PSL Power Supply (catalog numbers 09-AL09 and 09-BL0) AC Line Filter CB PS 0 W, A V DC Power Supply Line Interface Module PSL- PSL- MBRK PWR PSL- PSL- MBRK COM Rockwell Automation Publication 09-IN00I-EN-P - June 0

25 Line Interface Module Control Power Supply The control power supply on 09-ALxxS, 09-BLxxS, and 09-XL7S-C line interface modules is protected by FB and one -pole circuit breaker (CB). The control power supply on 09-AL09 and 09-BL0 line interface modules is protected by one -pole circuit breaker (CB). They all have a single-phase filter placed in the control VAC supply to provide protection/conditioning. For safety reasons, the internal wiring is arranged so that, if the control power (CPL) circuit breaker (CB) trips, the opening contact will interrupt the coil voltage. Circuit breaker CB and fuse block FB are field-replaceable. For FB replacement fuse part numbers, see the table on page 0. Table 6 - Control Power Output Source Cat. No. Input Voltage Control Power Source 09-ALxxS 0V AC Two phases of incoming power. 09-AL09 (internal connection) 09-XL7S-C Auxiliary 0V AC input (APL) connector. 0/60V AC 09-XL7S-C Auxiliary 0V AC input (APL) connector. 09-BLxxS 60V AC Internal step down transformer. 09-BL0 See Power Specifications beginning on page for control power output (CPL) specifications. Figure 9 - CPL Power Supply (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) CB_AUX Line Interface Module FB CB Single-phase AC Line Filter CPL- CPL- CTRL CTRL Figure 0 - CPL Power Supply (catalog numbers 09-AL09 and 09-BL0) Line Interface Module COIL_A (CR) COIL_A (IOL-) Single-phase AC Line Filter CB 6 CPL- CPL- L L/N Rockwell Automation Publication 09-IN00I-EN-P - June 0

26 6 Line Interface Module Auxiliary Power Output An auxiliary 0V AC output is provided for use with the Bulletin 090 resistive-brake module (RBM) or other customer requirement as needed on the PL connector. This supply is present with 09-ALxxS, 09-BLxxS, and 09-XL7S-C line interface modules. The supply is protected by circuit breaker CB. IMPORTANT Auxiliary power output (PL) is 0V AC with catalog number 09-XL7S-C. Figure - PL 0V Power (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-C) FB CB Line Interface Module PL- AUX_L PL- AUX_L PL- AUX_L PL- AUX_L See Power Specifications beginning on page for Auxiliary Power Output (PL) specifications. Auxiliary Power Input The auxiliary power input (APL) connector is available only with the 09-XL7S-C and 09-XL7S-C line interface modules. This connector allows the customer to provide a separate auxiliary power source, independent from the mains supply, for control power and other uses. The APL connector will accept either 0V (09-XL7S-C) or 0V AC (09-XL7S-C) input voltage. As a result, the auxiliary power output (PL) and control power output (CPL) voltage is 0V or 0V AC, respectively. The V power supply is designed to operate on either 0V or 0V AC and will auto-detect the input voltage. See Power Specifications beginning on page for auxiliary power input (APL) and auxiliary power output (PL) specifications. See page 7 for the 09-XL7S-Cx line interface module block-diagram. Rockwell Automation Publication 09-IN00I-EN-P - June 0

27 Line Interface Module 7 Install the Line Interface Module This procedure assumes that you have prepared your panel and understand how to bond your system. See the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM00, for information on high-frequency bonding and reducing electrical noise. ATTENTION: To avoid hazard of electrical shock, mount your line interface module to the panel before applying power. Once power is applied, connector terminals may have voltage present even when not in use. IMPORTANT If you are using the 09 mounting brackets and plan to mount your line interface module over the AC line filter, you must install the line filter and brackets first. See the 09 Mounting Brackets Installation Instructions, publication 09-IN008, for that information. Only the 09-ALxxS and 09-XL7S-Cx line interface modules are compatible with the 09 mounting brackets. The 09-BLxxS, 09-AL09, and 09-BL0 line interface modules are not compatible. Mount the Line Interface Module Follow these steps to mount your line interface module to the panel.. Layout the position for your module in the enclosure. See Establishing Noise Zones beginning on page 6 for panel layout recommendations. See Product Dimensions beginning on page 8. IMPORTANT To improve EMC performance, mount the line interface module on the same panel as the drive and as close to the drive as possible.. Attach the line interface module to the cabinet. The recommended mounting hardware is M6 metric (/ in.) bolts. Make sure all fasteners are properly bonded to the subpanel.. Tighten all mounting fasteners. Rockwell Automation Publication 09-IN00I-EN-P - June 0

28 8 Line Interface Module 9.8 (0.) Product Dimensions Figure - Mounting Dimensions (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) 9-6 VAC LINE, 0/60 Hz 9-6 VAC LOAD, 0/60 Hz L L L L' L' L' CTRL CTRL AUX AUX AUX AUX I/O_COM I/O_PWR I/O_COM I/O_PWR I/O_COM I/O_PWR CONTROL VAC 0 VAC SUPPLY VDC SUPPLY Dimensions are in millimeters (inches) (catalog number 09-XL7S-Cx is shown) x (.0) Mounting features sized for M6 (/ ) hardware. Connectors not shown for clarity. 0.8 (0.) x 0.6 (.60) x.69 (0.0) 6.7 (.0) A 7.9 (.80) 09.9 (.0) x. (.87) 09.9 (.0) x (.0) 0 (8.66) Cat. No. Dimension A mm (in.) 09-ALxxS 09-XL7S-Cx 98. (7.8) 09-BLxxS 8.0 (9.76) Rockwell Automation Publication 09-IN00I-EN-P - June 0

29 Line Interface Module 9 Figure - Mounting Dimensions (catalog number 09-AL09) (.8) 8.7 (7.7) 87.7 (7.9) Dimensions are in millimeters (inches) x Ø 6 (0.6) 6x Ø 7.9 (0.).7 (0.) (0.87) 97 (7.7) 87.7 (7.9) x 8.7 (.) 86.8 (.9) (8.86). (9.97) 8.9 (0.) 0.9 (.) 0 (0.79). (.6) 8 (.).7 (0.) Flying-lead I/O Cable with 090-K6CK-D6M Low-profile Connector Kit 8 (.) IMPORTANT Additional clearance below the low-profile I/O connector is necessary to provide the recommended cable-bend radius. Rockwell Automation Publication 09-IN00I-EN-P - June 0

30 0 Line Interface Module Figure - Mounting Dimensions (catalog number 09-BL0) 00 (.7) 00 (.9) 77 (0.9) x 06 (8.) 80 (.0) Dimensions are in millimeters (inches) x 8. (.) 80 (.0) x 0. (.9) 7.6 (.09) x Ø 6 (0.6) x 8.7 (.) 6x Ø 7.9 (0.).7 (0.0) 89 (.7) (.8) 97 (7.8) 0 (9.8). (9.9) 78. (0.96) 8.9 (0.) 0 (0.79). () 80 (7.09) 60 (.7).7 (0.0) Flying-lead I/O Cable with 090-K6CK-D6M Low-profile Connector Kit. (0.) IMPORTANT Additional clearance below the low-profile I/O connector is necessary to provide the recommended cable-bend radius. Rockwell Automation Publication 09-IN00I-EN-P - June 0

31 Line Interface Module Wire the Line Interface Module This section provides wiring requirements for each connector on the line interface module. IMPORTANT The National Electrical Code and local electrical codes take precedence over the values and methods provided. Wire should be copper with 7 C (67 F) minimum rating. Phasing of main AC power is arbitrary and earth-ground connection is required for safe and proper operation. Use these tables to determine the recommended wire size, strip length, and torque value for wiring your line interface module. Table 7 - Wiring Requirements (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-C) Description Connects to Terminals Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) VAC LINE VAC LOAD IPL- IPL- IPL- IPL- OPL- OPL- OPL- OPL- L L L L L L. ( ) 6.0 (0.6).7 () Auxiliary power input () APL- L/N 0..0 APL- L ( 0) 7.0 (0.8) (..) Control power output CPL- CTRL 0..0 CPL- CTRL ( 0) 7.0 (0.8) (..) Auxiliary power output PL- PL- PL- PL- AUX_L AUX_L AUX_L AUX_L 0..0 ( 0) 7.0 (0.8) (..) Brake and I/O power output PL- PL- PL- PL- PL- PL-6 IO_PWR IO_COM IO_PWR IO_COM IO_PWR IO_COM (8 6) 7.0 (0.8) (.9.) Status I/O (-pin terminal block) IOL- IOL- 0.. ( ) 6.0 (0.). (0) () The auxiliary power input (APL) connector is present only on the 09-XL7S-Cx line interface modules. Rockwell Automation Publication 09-IN00I-EN-P - June 0

32 Line Interface Module Table 8 - Wiring Requirements (catalog numbers 09-AL09 and 09-BL0) Cat. No. Description Connects to Terminals Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) 09-AL09 (0V) VAC LINE VAC LOAD IPL- IPL- IPL- IPL- OPL- OPL- OPL- OPL- L L L L L L. () 0.0 (0.8) (..) 09-BL0 (60V) VAC LINE VAC LOAD IPL- IPL- IPL- IPL- OPL- OPL- OPL- OPL- L L L L L L.0 () 0.0 (0.8)..8 (..9) Common (0V or 60V) Control power output Brake and I/O power output CPL- CPL- PSL- PSL- PSL- PSL- L L/N MBRK PWR MBRK COM MBRK PWR MBRK COM. () 0.0 (0.8) (..) ATTENTION: To avoid hazard of electrical shock, complete the wiring of your module before applying power. Once power is applied, connector terminals may have voltage present even when not in use. ATTENTION: The input power for Bulletin 09 line interface modules must come from a grounded configuration. When an ungrounded power configuration is used, phases L, L, and L (without a reference to earth ground) can drift and stress the line-filter components internal to the line interface module. Your Bulletin 09, 09, and 099 servo drive user manual includes examples of grounded and ungrounded power configurations. See Additional Resources on page 6 for publication numbers. Rockwell Automation Publication 09-IN00I-EN-P - June 0

33 Line Interface Module Wiring Guidelines Use these guidelines as a reference when wiring the connectors on your line interface module. IMPORTANT See Connector Data on page 9 for the connector locations of your line interface module. When tightening screws to secure the wires, see the tables beginning on page for torque values. When removing insulation from wires, see the tables beginning on page for strip lengths. IMPORTANT To ensure system performance, run wires and cables in wireways as shown in Establishing Noise Zones on page 6. See Wiring Diagrams beginning on page for interconnect diagrams including the line interface module. Follow these steps when wiring the connectors on your line interface module.. Prepare the wires for attachment to each connector plug by removing insulation equal to the recommended strip length. IMPORTANT Use caution not to nick, cut, or otherwise damage strands as you remove the insulation.. Route the cable/wires to your line interface module.. Insert wires into connector plugs. See connector pinout tables beginning on page.. Tighten the connector screws.. Gently pull on each wire to make sure it does not come out of its terminal. If any wires are loose, then repeat steps and. 6. Insert the connector plug into the appropriate connector. Rockwell Automation Publication 09-IN00I-EN-P - June 0

34 Line Interface Module Wiring the Auxiliary-input Power (APL) Connector The auxiliary-input power (APL) connector is present only on the 09-XL7S-Cx line interface modules. Figure - Line Interface Module (APL connector) L/N L Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) Table 9 - Auxiliary Input Power (APL) Connector Single-phase Supply APL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L L 0..0 L L/N ( 0) 7.0 (0.8) (..) Rockwell Automation Publication 09-IN00I-EN-P - June 0

35 Line Interface Module Wiring the VAC LINE (IPL) Connector Figure 6 - Line Interface Module (IPL connector) Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) L L L ATTENTION: The input power for Bulletin 09 line interface modules must come from a grounded configuration. When an ungrounded power configuration is used, phases L, L, and L (without a reference to earth ground) can drift and stress the line filter components internal to the line interface module. Your Bulletin 09, 09, and 099 servo-drive user manual includes examples of grounded and ungrounded power configurations. See Additional Resources on page 6 for publication numbers. Table 0 - VAC LINE (IPL) Connector (catalog numbers 09-AL09, 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) -phase Supply IPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L L L L L L. ( ) 6.0 (0.6).7 () Table - VAC LINE (IPL) Connector (09-BL0 module) -phase Supply IPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L L L L L L.0 () 0.0 (0.8)..8 (..9) Rockwell Automation Publication 09-IN00I-EN-P - June 0

36 6 Line Interface Module Wiring the VAC LOAD (OPL) Connector Figure 7 - Line Interface Module (OPL connector) Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) L L L IMPORTANT The 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx line interface modules are capable of connecting to multiple drives, providing each drive has its own line filter and the maximum current specification is not exceeded. For example diagrams, see the user manual for your drive. See Additional Resources on page 6 for publications. Table - VAC LOAD (OPL) Connector (catalog numbers 09-ALxxS, 09-BLxxS, or 09-XL7S-Cx) -phase Supply OPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L L L L L L. ( ) 6.0 (0.6).7 () Table - VAC LOAD (OPL) Connector (catalog number 09-AL09) -phase Supply OPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L L L L L L. ( ) 6.0 (0.6).7 () Table - VAC LOAD (OPL) Connector (catalog number 09-BL0) -phase Supply OPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L L L L L L.0 () 0.0 (0.8)..8 (..9) Rockwell Automation Publication 09-IN00I-EN-P - June 0

37 Line Interface Module 7 Wiring the Control Power Output (CPL) Connector Figure 8 - Line Interface Module (CPL connector) Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) CTRL CTRL Table - Control Power Output (CPL) Connector (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) CPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) CTRL 0..0 CTRL ( 0) 7.0 (0.8) (..) Table 6 - Control Power Output (CPL) Connector (catalog numbers 09-AL09 and 09-BL0) CPL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) L. L/N () 0.0 (0.8) (..) Rockwell Automation Publication 09-IN00I-EN-P - June 0

38 8 Line Interface Module Wiring the Auxiliary Power Output (PL) Connector Figure 9 - Line Interface Module (PL connector) Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) AUX_L AUX_L AUX_L AUX_L Table 7 - Auxiliary Power Output (PL) Connector (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) PL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) AUX_L AUX_L AUX_L 0..0 ( 0) 7.0 (0.8) (..) AUX_L Rockwell Automation Publication 09-IN00I-EN-P - June 0

39 Line Interface Module 9 Wiring the Brake Power Output (V DC) Connector Figure 0 - Line Interface Module (V connector) Line Interface Module, Top View (catalog number 09-XL7S-Cx is shown) 6 IO_PWR IO_COM IO_PWR IO_COM IO_PWR IO_COM Table 8 - Brake Power Output (V DC) Connector (catalog numbers 09-ALxxS, 09-BLxxS, and 09-XL7S-Cx) PL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) IO_PWR IO_COM IO_PWR IO_COM (8 6) 7.0 (0.8) (.9.) IO_PWR 6 IO_COM Table 9 - Brake Power Output (V DC) Connector (catalog numbers 09-AL09 and 09-BL0) PSL Pin Signal Recommended Wire Size mm (AWG) Strip Length mm (in.) Torque Value N m (lb in) MBRK PWR MBRK COM MBRK PWR. () 0.0 (0.8) (..) MBRK COM Rockwell Automation Publication 09-IN00I-EN-P - June 0

40 0 Line Interface Module Configure Branch-circuit Protection Branch-circuit protection for the line interface module is customer configurable. By moving the CB/CB wiring harness (P) from one side of CB to the other, you can change the module operation. To understand this option, see the simplified block diagram and table below. Figure - Simplified Block Diagram (catalog numbers 09-ALxxS and 09-BLxxS) -phase Input (OPL) Line Interface Module Fuse Block Transformer (60V only) Optional Connection (after CB) J_B P J Disconnect (0U-H-RMB) Circuit Breaker (CB) Default Connection (before CB) Circuit Breaker (CB) Circuit Breaker (CB) Safety Contactor Aux Power Output (PL) V DC I/O Power Output (IOL) V DC Aux Power Output (PL) 0V AC Control Power Output (CPL) 0V AC -phase Power Output (OPL) to Drive Table 0 - Branch-circuit Operation (catalog numbers 09-ALxxS and 09-BLxxS) Cat. No. Branch-circuit Protection Configurations Module Operation 09-ALS, 09-ALS, 09-AL0S, 09-AL7S () (0V) line interface modules 09-BL0S, 09-BLS, 09-BL0S, 09-BL7S () (60V) line interface modules () Applies to 09-ALxxS and 09-BLxxS (series B) line interface modules only. Input VAC to CB and CB before CB (default configuration) Input VAC to CB and CB after CB (optional configuration) Closing CB removes -phase power to the device (servo drive), however V DC (CB) and 0V AC (CB) auxiliary circuits remain energized. Closing CB removes all power to the line interface module. IMPORTANT For the input VAC to CB/CB before CB (default) configuration, no action is required. Follow these steps to move the CB/CB wiring harness to the optional configuration.. Remove all input power from the line interface module. ATTENTION: To avoid shock hazard or personal injury, verify that all power has been removed before proceeding. This system may have multiple sources of power. Multiple disconnect switches may be required to de-energize the system. Rockwell Automation Publication 09-IN00I-EN-P - June 0

Removing and Replacing the Line Interface Module Internal Components

Removing and Replacing the Line Interface Module Internal Components Installation Instructions Removing and Replacing the Line Interface Module Internal Components Catalog Numbers 09-ALS, 09-ALS, 09-AL0S, 09-AL7S, 09-BL0S, 09-BLS, 09-BL0S, 09-BL7S, 09-XL7S-C, 09-XL7S-C,

More information

Bulletin 2094 Mounting Brackets

Bulletin 2094 Mounting Brackets Bulletin 2094 Mounting Brackets The Bulletin 2094 mounting brackets (catalog number 2094-XNBRKT-1) are designed to save panel space by letting you mount the Bulletin 2094 power rail or line interface module

More information

Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules

Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Catalog Numbers 2094-BC01-MP5-M, 2094-BC01-M01-M, 2094-BC02-M02-M, 2094-BC04-M03-M, 2094-BC07-M05-M, 2094-BMP5-M, 2094-BM01-M,

More information

Kinetix 6000 Axis Module and Shunt Module

Kinetix 6000 Axis Module and Shunt Module Installation Instructions Kinetix 6000 and Shunt Module Catalog Numbers 2094-AMxx, 2094-BMxx 2094-AMxx-S, 2094-BMxx-S 2094-BSP2 Topic Page About This Publication 1 Important User Information 2 Before You

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

Kinetix 5500 Servo Drives

Kinetix 5500 Servo Drives Installation Instructions Kinetix 5500 Servo Drives Catalog Numbers 98-H003-ERS, 98-H008-ERS, 98-H05-ERS, 98-H05-ERS, 98-H040-ERS, 98-H070-ERS, 98-H003-ERS, 98-H008-ERS, 98-H05-ERS, 98-H05-ERS, 98-H040-ERS,

More information

Installation Instructions

Installation Instructions Installation Instructions Cat. No. 1771 P3, P4, P5 and P5E Use this document as a guide when installing the catalog number 1771-P3, -P4, -P5 or -P5E power supplies. Because of the variety of uses for the

More information

Kinetix 2000 Integrated Axis Module and Axis Module

Kinetix 2000 Integrated Axis Module and Axis Module Installation Instructions Kinetix 2000 Integrated Axis Module and Axis Module Catalog Numbers 2093-AC05-MP1, 2093-AC05-MP2, 2093-AC05-MP5, 2093-AMP1, 2093-AMP2, 2093-AMP5, 2093-AM01, 2093-AM02 Topic Important

More information

Differential Liquid/Gas Pressure Transmitter

Differential Liquid/Gas Pressure Transmitter Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 71-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Because of the variety of uses for the products described in this publication, those responsible for the application and use

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-OD) This document provides information on: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About

More information

Kinetix 7000 High Power Servo Drives

Kinetix 7000 High Power Servo Drives Installation Instructions Kinetix 7000 High Power Servo Drives Catalog Numbers 2099-BM06-S, 2099-BM07-S, 2099-BM08-S, 2099-BM09-S, 2099-BM10-S, 2099-BM11-S, 2099-BM12-S Topic Page About the Kinetix 7000

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1771-OBN Series B) Use this document as a guide when installing the catalog number 1771-OBN series B output module. Because of the variety of uses for the products described

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

InView Firmware Update

InView Firmware Update Installation Instructions InView Firmware Update Topic Page Hazardous Voltage 3 Change EPROM on 2706-P72, 2706-P74 Display 3 Change EPROM on 2706-P42, 2706-P44 Displays 5 Firmware Upgrade Kit 7 2 InView

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

ArmorPoint I/O Field Potential Distributor, Series A

ArmorPoint I/O Field Potential Distributor, Series A Installation Instructions ArmorPoint I/O Field Potential Distributor, Series A (Cat. No. 1738-FPD) The field potential distributor (Cat. no. 1738-FPD) lets you change the field power distribution source

More information

Quick Start. Logix5000 Control Systems: Connect Kinetix 5500 Drives over an EtherNet/IP Network

Quick Start. Logix5000 Control Systems: Connect Kinetix 5500 Drives over an EtherNet/IP Network Quick Start Logix5000 Control Systems: Connect Kinetix 5500 Drives over an EtherNet/IP Network Important User Information Read this document and the documents listed in the additional resources section

More information

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Installation Instructions PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Catalog Number 6189V-2PCI15R Topic Page About This Publication 1 Important User Information 2 Safety

More information

Quick Start. Logix5000 Control Systems: Connect Kinetix 350 Drives over an EtherNet/IP Network

Quick Start. Logix5000 Control Systems: Connect Kinetix 350 Drives over an EtherNet/IP Network Quick Start Logix5000 Control Systems: Connect Kinetix 350 Drives over an EtherNet/IP Network Important User Information Read this document and the documents listed in the additional resources section

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

Embedded I/O Expansion Board with 10 Outputs

Embedded I/O Expansion Board with 10 Outputs Installation Instructions Embedded I/O Expansion Board with 10 Outputs Catalog Number 1799-OQ10X Topic Page Important User Information 2 Environment and Enclosure 3 About the Board 4 Install the Board

More information

InView Communication Modules

InView Communication Modules Installation Instructions InView Communication Modules Catalog Numbers 2706-PxM, 2706-PxK, 2706-PxP Topic Page About This Publication 1 Important User Information 2 Power Supply Requirements 3 Mount the

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

Application Technique. Safety Function: Safety Camera with E-stop

Application Technique. Safety Function: Safety Camera with E-stop Application Technique Safety Function: Safety Camera with E-stop Products: Guardmaster Dual-input Safety Relay, Guardmaster SC300 Safety Camera Safety Rating: PLd, Cat. 3 to EN ISO 13849-1: 2008 2 Safety

More information

The identified danger could cause physical and property damage.

The identified danger could cause physical and property damage. Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

UniStream HMI Panel. CPU-for-Panel

UniStream HMI Panel. CPU-for-Panel UniStream HMI Panel Installation Guide USP-070-B10,USP-104-B10, USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This

More information

Installing Your 1394 Drive Interface Module

Installing Your 1394 Drive Interface Module Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

PanelView 600 Terminals

PanelView 600 Terminals Installation Instructions PanelView 600 Terminals Catalog Numbers 2711-K6Cxx, 2711-B6Cxx Topic Page Hazardous Location Considerations 3 European Union Directive Compliance 4 Wiring and Safety Guidelines

More information

Kinetix 300 Memory Module Programmer

Kinetix 300 Memory Module Programmer Kinetix 300 Memory Module Programmer Catalog Number 2097-PGMR Topic About the Memory Module Programmer 1 Parts List 3 Batteries Operation 4 Using Memory Module Programmer 6 Switch On/Off Memory Module

More information

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual. DriveGuard Safe-Off Option for PowerFlex 70 AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0 170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

Installation Instructions

Installation Instructions 50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation

More information

Kinetix 350 Single-axis EtherNet/IP Servo Drives

Kinetix 350 Single-axis EtherNet/IP Servo Drives User Manual Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM, 2097-V33PR5-LM,

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS SensaGuard Non-contact Interlock Switch with E-stop Table of Contents: Important User Information 45 General Safety Information 45 Introduction

More information

PowerMonitor 1000 Unit Catalog Number Upgrade

PowerMonitor 1000 Unit Catalog Number Upgrade Installation Instructions PowerMonitor 1000 Unit Catalog Number Upgrade Catalog Numbers 1408-UPT1-E3, 1408-UPT2-E3, 1408-UPE1-E3, 1408-UPE2-E3, 1408-UP485-ENT, 1408-UPT3-E3 Topic Important User Information

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch Safety Application Example GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch Safety Rating: PLd, Cat. 3 to EN ISO 13849.1 2008 Introduction... 2 Important User Information...

More information

Allen-Bradley Motors

Allen-Bradley Motors Installation Instructions Firmware Update Instructions for Ethernet, Enhanced and ControlNet PLC-5 Programmable Controllers Purpose Firmware Update Kit Contents Hardware and Software Requirements This

More information

DeviceNet ArmorBlock Network Powered 16-input Module

DeviceNet ArmorBlock Network Powered 16-input Module Installation Instructions DeviceNet ArmorBlock Network Powered 16-input Module Catalog number 1732D-IBDPM12MND, Series A Table of Contents Topic Page Important User Information 2 Environment and Enclosure

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

GuardLogix: Safety Gate Application with SensaGuard Switch

GuardLogix: Safety Gate Application with SensaGuard Switch Safety Application Example GuardLogix: Safety Gate Application with SensaGuard Switch Safety Rating: PLe, Cat. 4 to EN ISO 13849.1 2008 Introduction...2 Important User Information...2 General Safety Information...3

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

Encoder Output Module

Encoder Output Module User Manual Original Instructions Encoder Output Module Catalog Number 2198-ABQE Important User Information Read this document and the documents listed in the additional resources section about installation,

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Chameleon Stand-alone

Chameleon Stand-alone Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Analog Output Module. ST-4xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series 1 FnIO S-Series Analog Output Module ST-4xxx User Manual Version 1.01 2012 CREVIS Co.,Ltd 2 FnIO S-Series DOCUMENT CHANGE SUMMARY REV PAGE REMARKS DATE EDITOR 1.0 New Document 2011/10/07 JE KANG 1.01 5

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those

More information

PowerMonitor 5000 Unit Catalog Number Upgrade

PowerMonitor 5000 Unit Catalog Number Upgrade Installation Instructions PowerMonitor 5000 Unit Catalog Number Upgrade Catalog Numbers 1426-MxE-xxx Topic Page Upgrade the Device Catalog Number with the ControlFLASH Utility 3 Determine Communication

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

User safety and equipment protection guidelines

User safety and equipment protection guidelines Snap-in I/O Module The V200-18-E1 plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. The module offers: 3 analog inputs 16 digital

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH) Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Allen-Bradley Spares. Ultra3000 Digital Servo Drive Installation Manual. Document Update. About This Publication

Allen-Bradley Spares. Ultra3000 Digital Servo Drive Installation Manual. Document Update. About This Publication Document pdate ltra000 Digital Servo Drive Installation Manual Catalog Numbers 098-DSD-00, -00, and -00 098-DSD-xxxX 098-DSD-xxxSE 098-DSD-xxx-DN 098-DSD-xxxX-DN 098-DSD-00, -07, and -0 098-DSD-xxxX 098-DSD-xxxSE

More information

Vision OPLC. V T38 Installation Guide. General Description

Vision OPLC. V T38 Installation Guide. General Description Vision OPLC V130-33-T38 Installation Guide The Unitronics V130-33-T38 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 2 HSC/Shaft-encoder Inputs 16

More information

This guide provides basic information for Unitronics controller model V T2.

This guide provides basic information for Unitronics controller model V T2. Vision OPLC 12 pnp/npn Digital, including 2 Analog, 3 HSC/Shaftencoder Inputs, 12 Transistor Outputs This guide provides basic information for Unitronics controller model V350-35-T2. General Description

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120. Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information