RCDs RCBOs MCBs Isolating Switches Switchboards

Size: px
Start display at page:

Download "RCDs RCBOs MCBs Isolating Switches Switchboards"

Transcription

1 RCDs RCBOs MCBs Isolating Switches Switchboards F:

2 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable for houses, office buildings and industrial installations. RCD 4 Pole 30ma 6KA 40A 63A Product Code RCD40-2 RCD63-2 Pole configuration: : Residual current Irn: Sensitivity: Approval No: 4 pole 40A 30ma 6 ka V08262/01 WIRING DIAGRAM N mm 32mm 45mm T 50mm 65mm 71mm N 2 4 6

3 RCD 2 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable for houses, office buildings and industrial installations. RCD 2 Pole 30ma 6KA 40A 63A Product Code RCD40-2 RCD63-2 Rated Voltage Rated Frequency Rated Residual Operating Current Rated Current Number of Poles Mounting 230/240AC 50/60Hz 30mA 40A, 63A 2P+N DIN Rail Mounting Standard IEC RCD Dimensions 65mm x 82mm WIRING DIAGRAM 82mm 32mm 45mm T N 1 50mm 65mm 35mm N 2

4 RCBOs 2Pole 6KA and 10KA RCBOs are combined mechanisms that provide overcurrent and earth leakage protection. RCBOs 2 Pole 30ma 6KA 10A 16A 20A 25A 32A 40A Product Code RCBO-10A-2M-6KA RCBO-16A-2M-6KA RCBO-20A-2M-6KA RCBO-25A-2M-6KA RCBO-32A-2M-6KA RCBO-40A-2M-6KA RCBOs 2 Pole 30ma 10KA 10A 16A 20A Product Code RCBO-10A-2M-10KA RCBO-16A-2M-10KA RCBO-20A-2M-10KA Residual current Irn Pole type Sensitivity Approval No 30ma 2 pole 6 KA V08087/01 WIRING DIAGRAM 32mm 45mm 82mm N 1 T N 2 50mm 65mm 35mm

5 RCBO 1 Pole Single Module 6KA RCBOs are combined mechanisms that provide overcurrent and earth leakage protection. RCBOs 1 Pole Single Module 6KA Product Code 10A 16A 20A 25A AV6RCBO-1/10 AV6RCBO-1/16 AV6RCBO-1/20 AV6RCBO-1/25 Rated Voltage 230/240AC Rated Frequency 50/60Hz Rated Residual Operating Current 30mA Rated Current 10A, 16A, 20A, 25A Rated Breaking Capability 6kA Number of Poles 1P+N Electro-Mechanical Endurance 4000 Instantaneous Trip Type C-Type Mounting DIN Rail Mounting Standard IEC RCBO Dimensions 75mm x 86mm WIRING DIAGRAM

6 RCBOs 18mm 6KA RCBOs are combined mechanisms that provide overcurrent and earth leakage protection. RCBOs 18mm C Curve 30ma 6KA 6A 10A 16A 20A 25A 32A Product Code RCBO-6A-1M-6KA RCBO-10A-1M-6KA RCBO-16A-1M-6KA RCBO-20A-1M-6KA RCBO-25A-1M-6KA RCBO-32A-1M-6KA Residual current Irn Pole type Sensitivity Approval No 30ma 1 pole 6 ka V08664/01 WIRING DIAGRAM L IN 110mm 35mm 45mm L OUT OUT IN FE 56 mm 66mm 18mm 54mm

7 MCB 1 Pole 4.5KA / 10KA MCBs offer protection againts short-circuit and overload currents. They can be used in domestic, commercial and industrial electrical distribution systems. V08086/01 MCB 1Pole 10KA Product Code MCB 1Pole 4.5KA Product Code V08086/01 1A 10A 16A 20A 25A 32A 40A 50A 63A 100A MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB A 2A 3A 4A 5A 6A 10A 16A 20A 25A 32A 40A 50A 63A MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB MCB mm 36mm 45mm Pole configuration: 1 pole Curve Type C Breaking Capacity 4.5KA / 10 KA 50mm Approval No: V08086/01 65mm

8 Isolating Switch 100A To be used as a switch isolator in a circuit connection. In the open position, it complies with the requirements of the isolating function. Designed to match NB series MCBs and RCBOs. Suitable for domestic installations. CS08354/01 CS08354/01 Product code: SW100-1 Product code: SW100-3 Pole configuration: 1 pole Rated Voltage: 240V Single Phase Rated Frequency: 50/60Hz Rated Current: 100A Protection Degree: IP20 Pole configuration: 3 pole Rated Voltage: 415V Triple Phase Rated Frequency: 50/60Hz Rated Current: 100A Protection Degree: IP20

9 Switchboards Surface Covers Voltex switchboards are made with high quality fire resistance plastics and are available from 1 to 36 way. All our switchboards can incorporate our complete line of circuit breakers depending on your job requirements. Surface Cover, 1 way Code: SC-1 Surface Cover, 2 way Code: SC-2 Surface Cover, 4 way Code: SC-4 32mm(W) x 130mm(H) x 60mm(L) 50mm(W) x 130mm(H) x 60mm(L) 84mm(W) x 130mm(H) x 60mm(L) Surface Cover, 6 way Code: SC-6 Surface Cover, 8 way Code: SC-8 121mm(W) x 130mm(H) x 60mm(L) 157mm(W) x 130mm(H) x 60mm(L)

10 Switchboards Surface Mounting Voltex switchboards are made with high quality fire resistance plastics and are available from 1 to 36 way. All our switchboards can incorporate our complete line of circuit breakers depending on your job requirements. 4 way Code: SBS-4 6 way Code: SBS-6 8 way Code: SBS-8 12 way Code: SBS mm(W) x 200mm(H) 148mm(W) x 200mm(H) 184mm(W) x 200mm(H) 256mm(W) x 200mm(H) 18 way Code: SBS way Code: SBS way Code: SBS mm(W) x 200mm(H) 270mm(W) x 200mm(H) 270mm(W) x 200mm(H)

11 Switchboards Flush Mounting Voltex switchboards are made with high quality fire resistance plastics and are available from 1 to 36 way. All our switchboards can incorporate our complete line of circuit breakers depending on your job requirements. Flush Mounting, 12 way Code: SBF-12 Flush Mounting, 18 way Code: SBS-18 Flush Mounting, 24 way Code: SBS mm(W) x 247mm(H) x 30mm(L) Box: 256mm(W) x 197mm(H) x 65mm(L) 413mm(W) x 266mm(H) x 30mm(L) Box: 362mm(W) x 213mm(H) x 65mm(L) 413mm(W) x 266mm(H) x 30mm(L) Box: 362mm(W) x 213mm(H) x 65mm(L) L W L H W H Plastic box

12 Switchboards Weatherproof MCB Enclosure Voltex switchboards are made with high quality fire resistance plastics and are available from 1 to 36 way. All our switchboards can incorporate our complete line of circuit breakers depending on your job requirements. MCB Enclosure 4 Pole Code: C66CB4N International Protection IP66 W/Proof MCB Enclosure 8 Pole Code: C66CB8N International Protection IP66 100mm(W) x 190mm(H) x 100mm(L) 170mm(W) x 190mm(H) x 100mm(L)

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

Protect Circuit Protection

Protect Circuit Protection Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and

More information

ic60n RCBO 30 ma IEC , IEC , AS/NZS

ic60n RCBO 30 ma IEC , IEC , AS/NZS ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of

More information

DSE201, DSE201 M Compact design with enhanced protection

DSE201, DSE201 M Compact design with enhanced protection DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection

More information

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1 F550e E-learning course Residual current devices basics RCDs Standards April 2, 2009 Slide 1 Objectives After completing this module, you will be able to have a clear overview of the residual current device

More information

RB60 RANGE. Miniature circuit breakers

RB60 RANGE. Miniature circuit breakers RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Panel Board & Miniature Circuit Breakers

Panel Board & Miniature Circuit Breakers A4 Panel Board & Miniature CONTENTS Features A4-02 Panel Board Type A4-04 External Dimensions & Panel Board Type A4-08 Panel Board Type A4-10 Panel Board Type Earth Leakage A4-12 Panel Board Type A4-14

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N

W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N Seybelgasse 13, A - 1230 Wien, TELEFON +43 1/866 85-0 E-MAIL info@schrack.at, INTERNET www.schrack.at PAGE 1/26 W RCBO COMBINED MCB AND RCCB SERIES

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards

ßCompliant with Amendment 3 ßBSEN for easy cabling. accommodate RCBOs. meeting current standards CHINT EUROPE (UK) LTD Chint Metal Consumer Units ßCompliant with Amendment 3 of BS 7671 : 2008 Regulation 421.1.201 ßBSEN 61439-3 3 to 36 Ways are Standard Specials to Customer Requirements ß 1mm steel

More information

Common Departures Interconnecting Facilities Requirements

Common Departures Interconnecting Facilities Requirements Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

L.V. Systems & Solutions

L.V. Systems & Solutions GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control

More information

Combined RCD/MCB Devices FRBmM, 1+N-pole

Combined RCD/MCB Devices FRBmM, 1+N-pole Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current

More information

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,

More information

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices FRCdM Type B, B+ and Bfq Digital Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :

Miniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data : Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Add-on Residual Current Protection PBSM MW

Add-on Residual Current Protection PBSM MW SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Residual Current Devices drcm Digital

Residual Current Devices drcm Digital Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.

More information

Horizontal distribution busbar HX 3 80/125 A plug-in

Horizontal distribution busbar HX 3 80/125 A plug-in 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification

Sentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification TD255 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully

More information

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

ESS20 Electronic Circuit Breaker

ESS20 Electronic Circuit Breaker ESS20 Electronic Circuit Breaker How does (selective) protection of loads work with DC 24 V power distribution systems? E-T-A's latest product. The 24V power supply Transformer or switch-mode? The well-proven

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000

More information

RCDs: everything an electrician should know

RCDs: everything an electrician should know RCDs: everything an electrician should know Electricians do the best they can every day they go to work and we want to leave a job safer than when we found it. But what if despite our best efforts, we

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

PD-Series General Specifications

PD-Series General Specifications PD-Series General Specifications SmartGuard is an equipment ground fault protection device that combines hydraulic/magnetic circuit breaker and overload and short circuit protection and ground fault protection.

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

POWER DISTRIBUTION CHAPTER 18

POWER DISTRIBUTION CHAPTER 18 Circuit Breakers - 01 Main Switches & Isolators - 12 Residual Current Devices - 14 Surge Arrestors & Diverters - 21 Circuit Breaker Enclosures - Load Centres - 22 Distribution Boards - 30 Load Break Switches

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

NEW Titan II A & B Distribution Boards

NEW Titan II A & B Distribution Boards A Type Board Specification: Powder Coated Epoxy Resin Finish RAL 7035 Designed and built in the UK to BS EN 60439 Maximum busbar rating 125A Degree of protection IP3X to BS EN 60529 Blank gland plates

More information

Module 18plus. Description. 18plus

Module 18plus. Description. 18plus Module 8plus Description Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its

Sentry. The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its Sentry 2 TECHNICAL HOTLINE +44 (0)268 563720 The Sentry range of Consumer Units from MK Electric has been stylishly designed to blend in with its environment. The curved lines and slim-line appearance

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery

More information

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400 Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

LC SmartGlass SPD SmartGlass

LC SmartGlass SPD SmartGlass LC SmartGlass SPD SmartGlass Electrical Installation Manual Ireland 21 Cookstown Industrial Estate, Tallaght, Dublin 24, Ireland. Tel: +353 (0)1 462 9945 or 9949 Fax: +353 (0)1 462 9951 United Kingdom

More information

Minimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules

Minimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules Minimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules The complete evolution DS203NC and ABB modular range: absolute integration ABB is present on the market of electric installations with

More information

Thermal-Magnetic Circuit Breaker 4220-T...

Thermal-Magnetic Circuit Breaker 4220-T... Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With

More information

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Defender B Board. Make The Switch

Defender B Board. Make The Switch Defender B Board Make The Switch Defender B Board 1.2mm Electro Galvanised Sheet Steel Tested to BS EN61439-3 Busbar Short Time Withstand Rating Icw 20kA 0.25s Tested at 35 C Ambient Tin Plated Busbar,

More information

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Figure.1 Altech s three new series deliver multiple capabilities. In all three series, ground fault sensitivity levels range

More information

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Ihr autorisierter Distributor: Neumüller Elektronik GmbH IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet

More information

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit. Installation Manual Govna B60PVM Voltage Optimisation Unit Govna B60PVM Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Web: www.renewableenergyhub.co.uk Email: info@renewableenergyhub.co.uk Phone: 0845 862

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways.

Doepke MAIN SWITCH OPTIONS. The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Doepke The insulated consumer unit range consists of four enclosure sizes to enable any combination from 1 to 16 usable ways. Designed to meet BSEN60439-3 these easy to install consumer units accept the

More information

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual Installation Manual V2.2 November 2015 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations, BS7671 (17th Edition or later) and current

More information

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories

Consumer Units IP Rated & Metal Enclosures Devices - MCBs, RCBOs & RCDs. Control Devices & Accessories Consumer Units IP Rated & Metal Enclosures Devices MCBs, RCBOs & RCDs Control Devices & Accessories Modern stylish design with a profile that matches Nexus wiring accessories Quality designed in Flexibility

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications. Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

TP&N DISTRIBUTION BOARD TYPE B RANGE

TP&N DISTRIBUTION BOARD TYPE B RANGE GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial

More information

For Sales and Support call KMParts.com (866)

For Sales and Support call KMParts.com (866) Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping

More information

B60 Domestic Voltage Optimisation Unit

B60 Domestic Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,

More information

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011 Technical Data 2CDC505082D0203 ABB i-bus KNX Product description Switch Actuators SA/S x.16.6.1, 16/20 A are modular installation devices in ProM design for installation in the distribution board. They

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Autoprotected Surge Arresters New OVR Plus range

Autoprotected Surge Arresters New OVR Plus range Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the

More information

phone fax post web ordering information Please call for the latest pricing or to request a free price list.

phone fax post  web ordering information Please call for the latest pricing or to request a free price list. switchgear everything for those switched on phone fax post email web ordering information Please call for the latest pricing or to request a free price list. opening an account To open a 30 day credit

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching

More information

INTERNATIONAL MODULAR WIRING DEVICES

INTERNATIONAL MODULAR WIRING DEVICES INTERNATIONAL MODULAR WIRING DEVICES International Configurations Inc s product range of Country specific modular wiring devices are designed for Worldwide construction projects, data centers, medical

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com www ElectricalPartManuals com multi 9, systematically Terminal distribution applications are large: housing, service sector and industry, and the needs are constantly changing Reconciling security and

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models with system diagnostics Very low zero-cross turn-on voltage Input and output protection and control LED standard IP20 protection by flaps on terminals With double removable

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

MCB. Elegance and precision engineering in the same breath. Range : upto 63Amps. Available in SP, SPN, DP, TP, TPN & FP version also Designed by HPL

MCB. Elegance and precision engineering in the same breath. Range : upto 63Amps. Available in SP, SPN, DP, TP, TPN & FP version also Designed by HPL MCB Elegance and precision engineering in the same breath. Range : upto 63Amps. Available in SP, SPN, DP, TP, TPN & FP version also Designed by HPL HPL Established in 1956, is among the leading players

More information

Residual Current Protective Devices / Arc Fault Detection Devices

Residual Current Protective Devices / Arc Fault Detection Devices Residual Current Protective Devices / Arc Fault Detection Devices SENTRON Configuration Manual Edition 10/015 siemens.com/lowvoltage Introduction 5SV / 5SM3 RCCBs 13 SIQUENCE 5SM3/5SU1 universal current

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg

EUSR. An Introduction To BS7671 Amendment 3:2015 DESIGNED FOR featuring Consumer Units for Domestic (Household) Premises as per Reg PR EUSR An Introduction To BS7671 Amendment 3:2015 featuring Consumer Units for Domestic (Household) Premises as per Reg. 421.1.201 DESIGNED FOR 2015 Third Amendment Update Significant Change 3rd Amendment

More information

PC-Series Ground Fault Circuit Protection

PC-Series Ground Fault Circuit Protection PC-Series Ground Fault Circuit Protection The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent

More information

Residential circuit protection buyers guide

Residential circuit protection buyers guide Residential circuit protection buyers guide 2 Contents The range overview... 4 Wiring regulation changes... 6 Domae consumer units... 8 Features and benefits... 9 Quick selector - reference numbers and

More information

Dtec Consumer units and

Dtec Consumer units and DTEC Consumer Units Dtec Consumer units and plastic distribution boxes Techna Dtec distribution boxes are available in a variety of stylish and ergonomic designs to suit any application. All our boxes

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

EMS CX 3 - Signalling Auxiliary Contact (CA + SD)

EMS CX 3 - Signalling Auxiliary Contact (CA + SD) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 EMS CX 3 - Signalling Auxiliary Contact Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V CP3E, 32E, 33E, 34E CP3V, 32V, 33V, 34V CP-E and CP-V circuit protectors 250V AC 0.05A to 30A 65V DC 0.05A to 30A Description CP-E, CP-V circuit protectors have been specially developed for computers,

More information