1 RB60 RANGE Miniature circuit breakers POWER 2015
2 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection of electrical circuit against overloads and short circuits. The devices are particularly recommended for residential and tertiary applications. Their main features are: Tripping characteristic, polarity and breaking capacity making them ideal for most installations. Suitable for the connection with cable or busbar. Clear contacts position displayed thanks to the frontal indicator. Highest limiting class. 2
3 The right offer The range of automatic circuit breakers RB60 are complete with every polarity 1P, 1P+N, 2P, 3P, 4P with rated current (In) from 6 to 63 A. The breakers, available in tripping characteristic C, with breaking capacity 6000 A in accordance with the standard EN and 6 ka in accordance with the standard EN guarantee a safe and reliable protection of electrical circuits. Flexible connection In order to meet any installation requirement, by means of the upper and the lower double connection, devices offer the possibility of busbars connection both at the top and at the bottom thus guaranteeing higher flexibility and faster installation. Safety displayed The position of contacts is easily recognizable as it is from the colour of frontal windows (red closed, green opened) that works independently from the lever. Ensured protection Contacts open immediately in case of short circuits: devices are therefore guaranteeing the highest limiting class 3 by limiting the reducing the electrical stress in cables and equipments in the plant. 3
4 RB60 range Miniature circuit breakers RB - Miniature circuit breakers RB60 - C Curve A (EN 60898) - 6 ka (EN ) GW91570 MINIATURE CIRCUIT BREAKERS Code Rated current Rated voltage No. of poles: 1P No. of modules EN Pack Carton GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 GW A V 1 12/120 No. of poles: 1P+N GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 GW A 230 V 2 6/60 No. of poles: 2P GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 GW A 400 V 2 6/60 No. of poles: 3P GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 GW A 400 V 3 4/40 No. of poles: 4P GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 GW A 400 V 4 3/30 4
5 Technical Data TYPE RB60 1P 1P+N 2P 3P 4P Rated current (In): (A) Curve: C C C C C Utilization category: A A A A A Rated operational voltage (Ue): (V) 230/ Insulation voltage (Ui): (V) Rated frequency: (Hz) 50/60 50/60 50/60 50/60 50/60 Rated impulse with stand voltage (Uimp): (kv) DIMENSION TABLES Breaking capacity AC - Alternating current IEC EN (A) Icn Ics AC - Alternating current IEC EN (ka) Icn Ics Wiring cable section (mm²) rigid 1~25 1~25 1~25 1~25 1~25 flexible 1~25 1~25 1~25 1~25 1~25 Electrical endurance (number of O-C cycles): Mechanical endurance (number of O-C cycles): ON/OFF status displayed: Red/Green Red/Green Red/Green Red/Green Red/Green Rated tightening torque: (Nm) Degree of protection terminals IP20 IP20 IP20 IP20 IP20 other parts IP40 IP40 IP40 IP40 IP P 2P (1P+N) 54 3P 72 4P
6 The Gewiss offer The full protection and distribution system 90 ReStart RANGE 90 ReStart range is made up of the reclosing innovative systems (ARD) for residual current circuit breakers able to reclose automatically devices in case of untimely trip only after checking the absence of earth fault in the plant. This range is available in RD, RM, AUTOTEST versions and offers the best solution for the service contuinity in residential, tertiary and industrial applications. ReStart RD: ARD for 2 and 4 poles residual current circuit breakers. ReStart RM e RM TOP: ARD for 2 and 4 poles residual current circuit breakers with overcurrent protection. ReStart AUTOTEST: the only residual current circuit breaker that in addition to the advantages of the ReStart function can automatically checking the proper functioning of protection without cutting power while performing the test. All the devices are available in PRO version that in case of impossibility to reclose the breaker because a real fault is present, keeps monitored the installation every 2 minutes and reclosing the circuit breaker when safe to do so. 90 MCB RANGE In addition to RB60 range, GEWISS offers solutions for every need of overloads and short circuit protection. The range is made up of three types of products: MTC compact miniature circuit breakers, from 2 to 32 A in B and C curve and breaking capacity up to 10 ka available in the 1P+N, 2P, 3P and 4P versions. The products ensure the protections in half the space than a traditional solution. MT miniature circuit breakers, from 1 to 63 A in B, C and D characteristic and breaking capacity up to 25 ka in every polarity (1P, 1P+N, 2P, 3P and 4P). MTHP high performance miniature circuit breakers, from 20 to 125 A in C and D curve and breaking capacity up to 25 ka in every polarity (1P, 2P, 3P and 4P). 90 RCD RANGE The 90 RCD range can meet any need for protection against earth fault, for all residential, tertiary and industrial applications. The range is made up of: MDC monoblock compact residual current circuit breakers with overcurrent protection from 6 to 32 A, in B and C curve, breaking capacity up to 10 ka and IΔn from 30 to 300 ma in AC, A, A[IR] (impulse resistance) and A[S] (selective) types. The products ensure the protections in half the space than a traditional solution. BD and BDHP modular add-on residual current devices for MT and MTHP from 25 to 125 A, IΔn from 10 ma to 3 A of AC, A, A[IR] impulse resistant, A[S] selective and A adjustable types. SD residual current circuit breakers from 25 A to 125 A, IΔn from 10 to 500 ma of AC, A, A[IR] and B[IR] impulse resistant, A[S] and B[S] selective. 6
7 90 AM RANGE The 90 AM range, beside the auxiliaries of the circuit breakers, common to the whole 90 MCB and MDC range, is made up of: Auxiliaries and accessories for modular circuit breakers: auxiliary contacts, releases, busbars, pole separator and padlocking lever block. Protection: LST surge protective devices, disconnectable fuse holders, residual current relay with separate toroid, motor protection switches. Control: switch disconnectors, latching relays, control relay, CTR contactors, installation relays. Programming: timers, twilight and astronomical time switches. Measurement: voltmeters, ammeters, current transformers, energy meters, multimeter and network analyser. Signalling: lights, push-buttons, bells and buzzers. MTX AND 97 MSS RANGE MTX is the molded case circuit breakers range that provides solutions for all tertiary and industrial applications, thanks to a wide range of features like: Rated current (1 a 1600 A). Breaking capacity (16 a 120 ka). Thermomagnetic and electronic tripping unit. Wide range of mechanical and electrical accessories. The MSS rotary switch disconnectors are guaranteed to be robust and reliable in the control and isolation of circuits up to 630 A. Four different sizes depending on the current 125 A,160 A, 250 A e 630 A. High performance, both in alternate and direct current. Automatic, motorised switchover system. 47 CVX RANGE The 47 CVX range is a system of metal distribution boards with a modern and smart design. The range is made up of: CVX 160 I and CVX 160 E monobloc flush- and wall- mounting distribution boards up to 160 A with drowable frame, available in IP versions. CVX 630 K modular wall- and floor- mounting distribution boards up to 630 A IP43. CVX 630 M monobloc wall- and floor- mounting distribution boards up to 630 A IP55. CVX 1600 modular distribution cabinet up to 3200 A IP65. 7
8 GEWISS S.p.A. Registered office: Via A. Volta, CENATE SOTTO (Bergamo) - Italy Tel Fax gewiss@gewiss.com - Sole Shareholder company - Bergamo Register of Companies/ VAT / Tax code (IT) REA Share Capital 60,000, EUR fully paid up PB EN
DSE201, DSE201 M Compact design with enhanced protection
DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection
More informationic60n RCBO 30 ma IEC , IEC , AS/NZS
ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationNEW 74 PS RANGE. Push-buttons, selectors and indicators ø 22mm
NEW 74 PS RANGE Push-buttons, selectors and indicators ø 22mm 74 PS RANGE Push-buttons, selectors and indicators ø 22mm The 74 PS range: a system of push-buttons, selectors and indicators with a 22mm diameter
More informationC60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)
DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables
More informationRCDs RCBOs MCBs Isolating Switches Switchboards
RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationmcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches
NEW P. 4 RX3 MCBs 63 A 4500 & 6000 prong type busbar MCBs, RCDs, add-on modules & accessories P. 9 DX3 RCBOs 63 A 6000 / 10 ka AC, A & Hpi type prong & fork type busbar P. 16 DX3 MCBs 63 A 50 ka mcbs,
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationMotors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB
Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics
More informationL.V. Systems & Solutions
GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationThe new Arc Fault Detection Device S-ARC1 Maximum safety easy installation
ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More information5SL Miniature Circuit Breakers
5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More information100% electricity. Automatic transfer switch controllers ATL series
100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationRESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)
Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) They react to sine-wave residual current (type AC) For protection: against dangerous contact with live parts (I Δn 30
More informationProtect Circuit Protection
Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationModular switch disconnectors and modular change-over switches
Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationvoltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection
voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) 030 23 030 28 039 21 039 33 039 34 Type 1 voltage surge protectors (V.S.P.) for main
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationEarth-fault Relay SPAJ 110 C. Product Guide
Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral
More informationProducts and solutions for generating sets
Products and solutions for generating sets www.lovatoelectric.com Tra dition and Innovation Since 1922 The first LOVATO Electric headquarters founded in Bergamo (Italy) in 1922: the starting point of the
More informationMinimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules
Minimum space, maximum protection DS203NC: 3P+N RCBOs in 4 modules The complete evolution DS203NC and ABB modular range: absolute integration ABB is present on the market of electric installations with
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationMultifunction
A = 0 047 40 0 047 41 0 047 42 0 047 00 0 047 43 0 047 45 0 047 44 Dimensions see e-catalogue For controlling the switching ON or OFF of a circuit (lighting, ventilation, automation, signalling) in operation
More informationMiniature. Circuit Breakers. reliable solutions for protection of installations against over-current phenomenon. Advantages for you : Technical data :
Miniature Circuit Breakers reliable solutions for protection of installations against over-current phenomenon Advantages for you : Bi-connect terminals for simultaneous termination of bus bar & wires Unique
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More information4. CIRCUIT BREAKERS. Functional Emergency Switching
4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationProducts Portfolio. Pole mounted Vacuum Recloser
Products Portfolio Pole mounted Vacuum Recloser Efacec Switchgear Efacec Switchgear is a leading company in Portugal and a worldwide reference in the development of solutions for power generation, transmission,
More informationSENTRON 3VL Molded Case Circuit Breakers
Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationResidential circuit protection buyers guide
Residential circuit protection buyers guide 2 Contents The range overview... 4 Wiring regulation changes... 6 Domae consumer units... 8 Features and benefits... 9 Quick selector - reference numbers and
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital Line-voltage independent, all-current sensitive RCCB for fault or additional protection with additional digital features System Monitoring: Preventive
More informationMOTOR & CIRCUIT PROTECTION
2 MOTOR & CIRCUIT PROTECTION Motor Protection Circuit Breakers p2-1 Motor Protection Relays p2-13 Thermistor Protection Relay p2-18 Fuse Holders p2-20 Miniature Circuit Breakers p2-23 Residual Current
More informationTP&N DISTRIBUTION BOARD TYPE B RANGE
GROUP Now included in the range: Extension Boxes Metering Kits Surge Suppression and more! TP&N DISTRIBUTION BOARD TYPE B RANGE A comprehensive distribution board range for modern commercial & industrial
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationOsiSwitch Limit Switches Innovation through modularity
OsiSwitch Limit Switches Innovation through modularity Osiswitch limit switches Simply Smart: Variable composition Note: All outline dimensions are in mm/inches Positive openings with rigid operators and
More informationHorizontal distribution busbar HX 3 80/125 A plug-in
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationAutoprotected Surge Arresters New OVR Plus range
Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationUS Catalog July 2016 SMISSLINE TP
US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationRedline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2
Redline Extensions All MCB s (except G20), RCCB s (except Delta B) & RCBO s are designed to accept the same family of extensions. Main device ON Normal working status Addon Devices The extensions intended
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationProducts and solutions for machine builders (OEM)
Products and solutions for machine builders (OEM) www.lovatoelectric.com Tra dition and Innovation Since 1922 The first LOVATO Electric headquarters founded in Bergamo (Italy) in 1922: the starting point
More informationSentry Technical. Consumer Units and Enclosures TD255. Standards and approvals. Description. Features. Technical specification
TD255 Consumer Units and Enclosures Standards and approvals All Sentry consumer units are designed to fully comply with the requirements of BS EN 60439-3. Weatherproof enclosures are designed to fully
More informationENERGY AND AUTOMATION
ENERGY AUTOMATION SINCE 1922 The first LOVATO Electric headquarters was established in Bergamo, Italy, in 1922: the starting point of a great industrial adventure. THE STORY OF A FAMILY, THE SPIRIT OF
More informationATS Automatic transfer switches Advanced version
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 ATS CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 5. CONFORMITY 4 6. EQUIPMENTS
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationSensitive Earth-fault Relay SPAJ 111 C. Product Guide
Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationFeeder protection relay SPAA 121 C. Product Guide
Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationType MVTT 14 and MVTT 15: Static Digital Time delay relays
Type MVTT 4 and MVTT 5: Static Digital Time delay relays Features 000/ setting range Time settings easily selected by means of thumbwheel switches Provide time delayed pick-up, or drop-off Compact construction
More informationAThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.
www.moeller.co.uk MCCB Panel Boards 400A / 630A / 800A Product Catalogue and Selection Guide MCCB Panel Boards Moulded Case Circuit Breakers and Accessories XBoard Consumer Units XPole Miniature Circuit
More informationWEG Contactors - CWM and CWME Series
Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationESS20 Electronic Circuit Breaker
ESS20 Electronic Circuit Breaker How does (selective) protection of loads work with DC 24 V power distribution systems? E-T-A's latest product. The 24V power supply Transformer or switch-mode? The well-proven
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More information