MTP TLC Adapter. Instructions for Use. Product description

Size: px
Start display at page:

Download "MTP TLC Adapter. Instructions for Use. Product description"

Transcription

1 CARE products are designed to support our worldwide customers with high-quality consumables, accessories and dedicated kits. The CARE product range is specifically optimized and certified for use with all Bruker Daltonics systems. Instructions for Use MTP TLC Adapter Accessory to enable the measurement of thin layer chromatography (TLC) plates and large-format glass slides in matrix-assisted laser-desorption/ionization (MALDI) mass spectrometers with ScoutMTP source 1) The product is for research use only. It is not for use in diagnostic procedures. Product description The MTP TLC Adapter (see Figure 1) is a dual-use adapter for TLC MALDI 1) and for MALDI Imaging applications to be measured on a Bruker ScoutMTP source MALDI instrument. 75 x 50 mm format TLC plates can be mounted on this adapter as well as the BigSlides for MALDI Imaging (# ) with the same format. Figure 1 MTP TLC Adapter 1 The coupling of thin layer chromatography and mass spectrometry is covered by the Bruker owned patents no. DE C2, GB B, and US 6,414,306 B1. Page 1 of 5

2 For TLC MALDI applications we recommend the use of 75 x 50 mm aluminium backed TLC silica gel plates (see recommendations in Ordering Information). Please note: Do not use TLC plates with glass (or other non-conductive) backing. MALDI TOF requires electrically conductive sample plates. n-conductive plates will cause electrostatic charging problems. For MALDI Imaging applications use dedicated 75x50 mm glass slides (BigSlides for MALDI Imaging, # ). These slides are equipped with a transparent electrically conductive ITO coating on one side. The coated side of the slide is easily visible when the box is open and can be checked with an ohmmeter. Make sure that you put the tissue sections on the coated side of the slides! Please note: Do not use uncoated glass slides. They will cause electrostatic charging problems. Ordering Information Product Unit Part. MTP TLC Adapter 1 pc BigSlides for MALDI Imaging 1 pck (one package contains 100 pcs) Software Requirements Compass Software for flex 1.3 (flexcontrol 3.3) and higher provides automated target geometry recognition. Some older versions only recognize the MTP TLC Adapter after installation of a free (see Table 1). Compass 1.1 and older do not support the TLC target. For support, please send an to maldi.sw.support@bruker.com. flexcontrol and flexanalysis have to be closed before running the setup. Table 1: Compass release Requirements for automatic recognition of the MTP TLC Adapter flexcontrol release Software Software upgrade Software upgrade te MALDI Imaging applications require Bruker fleximaging. Page 2 of 5

3 Mounting a TLC plate Place the adapter face-down on a table (see Figure 2a). First insert the TLC plate, then insert the metal stabilization plate and lock the retaining tabs following the procedure shown on Figure 2b to Figure 2f. a b c d e f Figure 2 Mounting of a TLC plate on the MTP TLC Adapter Mounting glass slides for MALDI Imaging The MTP TLC Adapter is also suitable for glass slides of a 75 x 50 mm format and suitable thickness for MALDI Imaging applications (e.g. BigSlides for MALDI Imaging, # ). Place the glass slide in the adapter as described for TLC plates in the above procedure and also mount the stabilization plate. The electrically coated side (with the tissue section applied) must face the front side of the adapter target! There is no risk that the tissue on the glass slide will touch the table as the protruding screws on the front side of the adapter act as a spacer. Matrix Application We recommend the use of the Bruker ImagePrep spray preparation device (# ) for matrix coating. Dedicated methods for TLC sample preparation are available for download from our homepage. Contact Bruker Support to obtain the relevant. MALDI Measurements TLC plates have a porous surface. This can lead to significantly prolonged pumping time when introducing TLC plates into the mass spectrometer. As a result, a timeout error may occur. If this happens, please repeat the introduction procedure. If this becomes a continuous error, please contact maldi.sw.support@bruker.com for assistance. Page 3 of 5

4 Teaching and Spot Localization For TLC MALDI applications use the metric scale on the adapter target to read out the lane positions. The coordinates can be entered directly into the TLC MALDI tool without any need for further teaching (see Figure 3). For MALDI Imaging applications use Bruker fleximaging to teach the tissue sample position. This provides a convenient 3-point teaching procedure which matches the microscopic image of the tissue section to the actual target position in the instrument (for details please refer to the online help for fleximaging). Coarse navigation on glass slides or TLC plates is simplified by using the 384 array coordinates: 1) put an MTP target cover plate (which is supplied with the adapter) onto the slide adapter, 2) label the spots of interest or the outer contour of the sections on the cover plate, 3) put the cover plate onto a conventional 384 target and read out the coordinates. Figure 3 How to read out the TLC lane coordinates and enter them into the TLC MALDI tool Page 4 of 5

5 Manufacturer Bruker Daltonik GmbH Fahrenheitstraße Bremen Germany Support maldi.appl.support@bruker.com Phone: Fax: Sales Information care@bruker.com Phone: Web: For research use only. t for use in diagnostic procedures. # Revision C, March 2016 Copyright 2016 Bruker Daltonik GmbH Descriptions and specifications supersede all previous information and are subject to change without notice. Page 5 of 5

MTP SmallAnchor Targets BC

MTP SmallAnchor Targets BC Instructions for Use MTP SmallAnchor Targets BC Polished steel targets with hydrophilic sample and calibrant spots surrounded by a hydrophobic barrier for MALDI sample preparation CARE products are designed

More information

CompassXport CompassXport

CompassXport CompassXport 1 Overview... 2 1.1 Introduction... 2 1.2 License Agreement... 2 2 Manuals... 2 3 Site Specifications... 2 3.1 Operating Systems... 2 4 Installation... 3 4.1 First time Installation... 3 4.2 Upgrade from

More information

SPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry

SPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry SPS3 autosampler For the Bruker 810/820-MS Innovation with Integrity Mass Spectrometry SPS3 autosampler The SPS3 Sample Preparation System, Bruker s fastest-ever spectroscopy autosampler, meets the diverse

More information

US IVD Bacterial Test Standard

US IVD Bacterial Test Standard Instructions for Use US IVD Bacterial Test Standard Mass calibration standard containing a typical Escherichia coli DH5 alpha peptide and protein profile plus additional proteins. For quality control and

More information

PAGE Electrophoresis and Blotting Eco-Line. Electrophoresis and Blotting

PAGE Electrophoresis and Blotting Eco-Line. Electrophoresis and Blotting PAGE Electrophoresis and Blotting Eco-Line Electrophoresis and Blotting 2 Eco-Line The Eco-Line offers tank-style systems for vertical gel electrophoresis with polyacrylamide gels. Two sizes are available:

More information

MALDI Biotyper Troubleshooting Guide

MALDI Biotyper Troubleshooting Guide Serial Number: MALDI Biotyper Troubleshooting Guide 605510 Revision B Calibration/Validation Issues If failed Validation, run Manual Calibration using flexcontrol software in RUO mode (shown in image below)

More information

Elcometer Protective Coatings Inspection Kits

Elcometer Protective Coatings Inspection Kits Inspection Kit 1 The Elcometer range of Protective Coatings Inspection Kits provide all the tools required for onsite inspection of a coating, including surface profile, dewpoint, relative humidity and

More information

F2A (M527) F2A (M506n/dn) F2A (M506x)

F2A (M527) F2A (M506n/dn) F2A (M506x) F2A76-67910 (M527) F2A68-67915 (M506n/dn) F2A68-67916 (M506x) Lea esto primero www.hp.com/support/lj506 www.hp.com/support/ljm527mfp CAUTION: Electrostatic sensitive (ESD) parts. Always touch the sheet-metal

More information

PL Cold Light Fiber Optical Technology

PL Cold Light Fiber Optical Technology A New Generation of Cold Light Sources PHOTONIC is one of the leading companies in the optics and opto-electronics industry and has gained a great deal of expertise in the field of light projection and

More information

TECTUS ENERGY TECTUS ENERGY. Integrated and permanent energy transfer

TECTUS ENERGY TECTUS ENERGY. Integrated and permanent energy transfer TECTUS ENERGY TECTUS ENERGY Integrated and permanent energy transfer 2 ENERGY TRANSFER TECTUS CONCEALED ENERGETIC POTENTIAL The completely concealed hinge system TECTUS carries loads of up to 300 kg, facilitates

More information

Data management for Proteomics ABRF 2005

Data management for Proteomics ABRF 2005 MASCOTIntegra Data management for Proteomics 1 Mascot Integra: Data management for proteomics What is Mascot Integra? What Mascot Integra is not Security and Electronic signatures in Mascot Integra Instrument

More information

SECULIFE IFPRO Infusion Pump Analyzer /7.17

SECULIFE IFPRO Infusion Pump Analyzer /7.17 3-349-991-03 2/7.17 PCA / Bolus Back Pressure Simulation Occlusion Alarm Trumpet Curve Analysis 1,2,3 and 4 Channel Models Available (Field Upgradeable) User Swappable Fully Self Contained Flow Modules

More information

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing D-Net CABINETS D-Net cabinets are a versatile racking system suitable for housing networking and various structured cabling components. D-Net Cabinets are manufactured in Taiwan in compliance with ISO9001:2000

More information

Single Cell Peptide Heterogeneity of Rat Islets of Langerhans

Single Cell Peptide Heterogeneity of Rat Islets of Langerhans Single Cell Peptide Heterogeneity of Rat Islets of Langerhans Erik T. Jansson, Troy J. Comi, Stanislav S. Rubakhin, and Jonathan V. Sweedler* Department of Chemistry and the Beckman Institute for Advanced

More information

Because Frozen Sections are Vitally Important

Because Frozen Sections are Vitally Important The Pathology Company Because Frozen Sections are Vitally Important Leica CM1860/CM1860 UV high-throughput clinical cryostat with AgProtect (with and without UV Protection) 2 3 Confidence is Vital Safety

More information

E- mail: SCHOTT NEXTERION Order Form 2015 FAX: Coated Microarray Slides

E- mail: SCHOTT NEXTERION Order Form 2015 FAX: Coated Microarray Slides SCHOTT NEXTERION Form 201 E- mail: Nexterion@appliedmicroarrays.com FAX: 480-77- 6184 Coated Microarray Slides Barcode option Pieces per pack List price (1-3 pks)** Slide A+ no 106487 2 $323.7 $12.9 Aminosilane

More information

CHROMABOND Flash cartridges

CHROMABOND Flash cartridges Flash chromatography outperforming the standard CHROMABOND Flash cartridges from the silica experts www.mn-net.com MN products for Flash chromatography Contents CHROMABOND Flash solutions separations from

More information

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442 Industrial Metrology Multisensor Measuring Machines O-INSPECT 322/442 The moment the answer is right in front of your eyes. This is the moment we work for. // Certainty Made By Zeiss 2 Table of Contents

More information

Polarizer Rotator 3 x 2 Slide Mount For GS12000 Series Polarizers User Manual

Polarizer Rotator 3 x 2 Slide Mount For GS12000 Series Polarizers User Manual Polarizer Rotator 3 x 2 Slide Mount For GS12000 Series Polarizers User Manual 2I-12500 Issue 5 Polarizer Rotator 3 x 2 Slide Mount For GS12000 Series Polarizers User Manual 2I-12500 Issue 5 User Manual

More information

Durable Metal IP66 Housing

Durable Metal IP66 Housing Durable Metal IP66 Housing Interchangeable Front IR Glasses Compatible with FLIR Ax5 cameras Brochure Workswell Fixed Housing for FLIR Ax5 cameras Workswell Fixed Housing is specially designed and manufactured

More information

ALPHA II. Innovation with Integrity. The benchmark for compact FTIR spectrometers FTIR

ALPHA II. Innovation with Integrity. The benchmark for compact FTIR spectrometers FTIR ALPHA II The benchmark for compact FTIR spectrometers Innovation with Integrity FTIR One Touch - Many Applications Verify/Identify Quantify Measure Search Efficient Quality Control Incoming goods inspection

More information

VINYL CUTTER C V SERIES

VINYL CUTTER C V SERIES VINYL CUTTER C V SERIES EN CV S E R I E S FEATURES 64 bit DC LITE Simple menu navigation Mac compatible USB Interface 64 bit compatible Plug & play Improved LAPOS DrawCut LITE VINYL CUTTER C V SERIES Secabo

More information

Dell OptiPlex All-in-One. Stand Installation Guide

Dell OptiPlex All-in-One. Stand Installation Guide Dell OptiPlex All-in-One Stand Installation Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

WinMax FAQs for distributor partners

WinMax FAQs for distributor partners Benefits 1. What is WinMax? WinMax is simply the best control software ever developed for the machine tool industry. WinMax Control Software is the new control that will be featured on all Hurco machine

More information

ALPHA II. Innovation with Integrity. The new benchmark for compact FTIR spectrometers FTIR

ALPHA II. Innovation with Integrity. The new benchmark for compact FTIR spectrometers FTIR ALPHA II The new benchmark for compact FTIR spectrometers Innovation with Integrity FTIR One Touch - Many Applications Verify/Identify Guided Workflow It takes only three touches for measurement, evaluation

More information

Bruker OminiFlex MALDI-TOF Mass Spectrometer Operation Quick Start

Bruker OminiFlex MALDI-TOF Mass Spectrometer Operation Quick Start Bruker OminiFlex MALDI-TOF Mass Spectrometer Operation Quick Start Sample preparation for the Bruker OminiFlex MALDI-TOF Mass Spectrometer is of crucial importance. Please take care when preparing your

More information

Mass Spec Data Post-Processing Software. ClinProTools. Wayne Xu, Ph.D. Supercomputing Institute Phone: Help:

Mass Spec Data Post-Processing Software. ClinProTools. Wayne Xu, Ph.D. Supercomputing Institute   Phone: Help: Mass Spec Data Post-Processing Software ClinProTools Presenter: Wayne Xu, Ph.D Supercomputing Institute Email: Phone: Help: wxu@msi.umn.edu (612) 624-1447 help@msi.umn.edu (612) 626-0802 Aug. 24,Thur.

More information

VINYL CUTTER T II SERIES

VINYL CUTTER T II SERIES VINYL CUTTER T II SERIES EN T II S E R I E S FEATURES TT 64 bit Simple Menu navigation Low noise Mac compatible 64 bit compatible Plug & play Servo motors High precision DC PRO LAPOS Q DrawCut PRO Cutting

More information

User Guide OMNI 97. For ipad 9.7, ipad Pro 9.7 and ipad Air ADVANCE RELEASE! (Product coming F/W 2017) [ Issued

User Guide OMNI 97. For ipad 9.7, ipad Pro 9.7 and ipad Air ADVANCE RELEASE! (Product coming F/W 2017) [ Issued ADVANCE RELEASE! (Product coming F/W 2017) User Guide OMNI 97 For ipad 9.7, ipad Pro 9.7 and ipad Air 2 Better Connection. Better Protection. [ Issued 09.07.2017. Version R1 ] 16. OMNI 97 User Guide For

More information

Quick Guide v. 3.0 Advanced model

Quick Guide v. 3.0 Advanced model Ultrasonic Thickness Gage Quick Guide v. 3.0 Advanced model Introduction The PosiTector UTG is a hand-held Ultrasonic Thickness Gage that uses the non-destructive ultrasonic pulse-echo principle to measure

More information

PT Teleprompter

PT Teleprompter Features you need, Prices you want. PT3000 15 Teleprompter User Guide 3903 Stoney Brook Dr. Houston TX 77063 Tel: 1.713.272.8822 Fax: 1.713.995.4994 www. support@ 2009 ikan Corporation. All right reserved.

More information

Upgrading the UltiMate 3000 RSLCnano System with ProFlow Technology

Upgrading the UltiMate 3000 RSLCnano System with ProFlow Technology Upgrading the UltiMate 3000 RSLCnano System with ProFlow Technology Quick Installation Guide Rev. 1.0 February 2016 Thermo Fisher Scientific Doc. No. 4820.4105 All rights reserved. Hystar is a trademark

More information

3025 MICROSCOPE SERIES INSTRUCTIONS

3025 MICROSCOPE SERIES INSTRUCTIONS 3025 MICROSCOPE SERIES INSTRUCTIONS Polysciences, Inc. 400 Valley Road Warrington, PA 18976 (800) 523-2575 / (215) 343-6484 (800) 343-3291 / (215) 343-0214 fax info@polysciences.com www.polysciences.com

More information

E SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS

E SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS Proven Reliability ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS 2V to 7kV at 3W / 8kV at 2W PRODUCT SELECTION TABLE Output Voltage (%) 14t 12 1 8 6 4 PRODUCT DESCRIPTION The E Series is a broad line of

More information

REMOTE HEAD ADAPTER INSTALLATION GUIDE

REMOTE HEAD ADAPTER INSTALLATION GUIDE REMOTE HEAD ADAPTER INSTALLATION GUIDE The Remote Head adapter is a valuable accessory for the Uniden BC-780, 785 and 796 scanners. It allows the scanner's control panel to be removed from the radio and

More information

MulTI-Touch Projected Capacitive Touch Screen Integration Guide

MulTI-Touch Projected Capacitive Touch Screen Integration Guide MulTI-Touch Projected Capacitive Touch Screen Integration Guide Document Number: 6500493 Rev. 1.1 Pg. 1 The information provided in this document is intended as a guide only and is subject to change without

More information

Going beyond the realm of switch technology:

Going beyond the realm of switch technology: FT Series FM & FK Series Going beyond the realm of switch technology: NKK s touch screens and membrane keypads ON/OFF NKK s Exceptional Standards as a Manufacturer of Industrial

More information

2-D Electrophoresis Solutions Complete 2-D System that

2-D Electrophoresis Solutions Complete 2-D System that 2-D Electrophoresis Solutions Complete 2-D System that Enables the Fastest Runs with the Clearest Spots The Only 2-D System able to Monitor Each Individual IPG Strip in Real Time with Graphical Display

More information

Integrated System for PAGE and Blotting

Integrated System for PAGE and Blotting Mini-V 8 10 Integrated System for PAGE and Blotting Mini-V 8 10 Gel Electrophoresis System Gel size 8.7 cm x 7.2 cm (W x L) Patented drop-in wedge automatically positions gels without the use of gaskets

More information

Technical Data Sheet. PEAK Measuring Microscope 2008 Series

Technical Data Sheet. PEAK Measuring Microscope 2008 Series PEAK Measuring Microscope 2008 Series Pocket Stand Microscope 25x, 50x, 75x, 100x magnification 0.05-0.005 mm measuring scale Measure width, thickness, height & depth Peak 2008 Stand Microscopes are small,

More information

PC-controlled Gel Documentation Systems Felix

PC-controlled Gel Documentation Systems Felix PC-controlled Gel Documentation Systems Felix UV-Fluorescence VIS-Fluorescence It s all about Bio-Imaging. www.biostep.de Felix 1010 - Getting started easily powerful digital reflex camera with manual

More information

VISY-X. Technical Documentation. Subsequent installation of VISY-Density. Edition: Version: 2 Art. No.:

VISY-X. Technical Documentation. Subsequent installation of VISY-Density. Edition: Version: 2 Art. No.: Technical Documentation VISY-X Subsequent installation of VISY-Density Edition: 2016-08 Version: 2 Art. No.: 350063 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49

More information

Thermo. EASY-nLC User Guide for LC Devices

Thermo. EASY-nLC User Guide for LC Devices Thermo EASY-nLC 1200 User Guide for LC Devices 60053-97273 Revision A September 2015 2015 Thermo Fisher Scientific Inc. All rights reserved. AFC, EASY-nLC, EASY-Column, EASY-Spray, Foundation, LC TriPlus,

More information

XL 4000 metal free-standing enclosures and cable compartments

XL 4000 metal free-standing enclosures and cable compartments 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3

More information

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers) Instructions (For 6180 Industrial Computers) This document describes how to remove or install a Pentium processor in the 6180 Industrial Computer. Processor specifications are also provided. The processor

More information

LBP2-SAM Series Beam Sampler for C-mount Cameras. User Notes

LBP2-SAM Series Beam Sampler for C-mount Cameras. User Notes LBP2-SAM Series Beam Sampler for C-mount Cameras P/N LBP2-SAM-UV, LBP2-SAM-VIS, LBP2-SAM-IR and LBP2-SAM-BB User Notes Newport Corporation 1791 Deere Avenue Irvine, CA 92606 www.newport.com For Sales,

More information

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. BPL SERIES INSTALLATION INSTRUCTIONS Important Warning THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This product must be installed in accordance with National Electrical

More information

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE Fully Featured Eddy Current Conductivity Meter ET NDE Introducing The SigmaCheck APPLICATIONS Material Verification / Metal Sorting. Heat Treatment Verification. Heat or Fire Damage Investigation. Non-conductive

More information

Movable Top Plate (MTP)

Movable Top Plate (MTP) Experts in Electrophysiology & Imaging Movable Top Plate (MTP) With manual adjusters Mounting equipment www.scientifica.uk.com 2 Movable Top Plate (MTP) This platform satisfies those wishing for manual,

More information

G SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS

G SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS 0 Proven Reliability G SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS 100V to 6kV at 1.5W PRODUCT SELECTION TABLE NOW UL RECOGNIZED % Of Full Output 100 90 80 70 60 50 40 30 20 10 PRODUCT DESCRIPTION

More information

Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters

Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters Growing With the Job... Quick, accurate and easy to use LPKF circuit board plotters have been meeting these user requirements

More information

Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters

Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters Growing With the Job... Quick, accurate and easy to use LPKF circuit board plotters have been meeting these user requirements

More information

Beholder FHS Flex Handle Stabilizer

Beholder FHS Flex Handle Stabilizer Beholder FHS Flex Handle Stabilizer V1.0 2017.07 Before using the product, please read manual carefully. Be sure to keep this manual in a safe place so that you can check it at anytime in the future. Table

More information

3D SYSTEMS University CubeX 3D Printer

3D SYSTEMS University CubeX 3D Printer 3D SYSTEMS University CubeX 3D Printer Lesson Leveling the Print Pad and Print Tips, Setting the Z-Gap Revision date: 10/22/13 1 1 2016 年 6 月 14 日 Objectives After completing this lesson you will: Be able

More information

Basler Accessories. Technical Specification dart I/O BOARD

Basler Accessories. Technical Specification dart I/O BOARD DRAFT Basler Accessories Technical Specification dart I/O BOARD Order Numbers 106896 dart I/O Board Starter Kit 106897 dart I/O Boards (5 Pieces) 2000035665 dart I/O Board Mounting Kit Document Number:

More information

Release Notes ZEN 2.3 SP1

Release Notes ZEN 2.3 SP1 Release Notes ZEN 2.3 SP1 Carl Zeiss Microscopy GmbH Carl-Zeiss-Promenade 10 07745 Jena, Germany microscopy@zeiss.com www.zeiss.com/microscopy Carl Zeiss Microscopy GmbH Königsallee 9-21 37081 Göttingen

More information

Door stopper, wall mounting 4-7 Door stopper, floor mounting 8-9. Door stopper, wall mounting 10 Door stopper, floor mounting 11

Door stopper, wall mounting 4-7 Door stopper, floor mounting 8-9. Door stopper, wall mounting 10 Door stopper, floor mounting 11 oor stopper : 8 Content oor stopper Seite Satin stainless steel oor stopper, wall mounting 4-7 oor stopper, floor mounting 8-9 Stainless Steel,black oor stopper, wall mounting 0 oor stopper, floor mounting

More information

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Installation Note Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Part Number E4401-90498 Supersedes: E4401-90332 Printed in USA July 2005 Notice.

More information

FTIR-7600 FT-IR Spectrometer Accessories Price List 2011

FTIR-7600 FT-IR Spectrometer Accessories Price List 2011 FTIR-7600 FT-IR Spectrometer Accessories Price List 2011 Lambda Scientific Systems, Inc. Part # Description of Item Price (USD) 50 Magnetic Film/Pellet Holder (for 13 mm film/pellet samples) The Magnetic

More information

Goto BRUKER BSMS, BSMS/2. RCB User Manual. Version 003 BRUKER

Goto BRUKER BSMS, BSMS/2. RCB User Manual. Version 003 BRUKER BRUKER BSMS, BSMS/2 RCB User Manual Version 003 BRUKER The information in this manual may be altered without notice. BRUKER accepts no responsibility for actions taken as a result of use of this manual.

More information

Cemented Achromatic Doublets. Specifications & Tolerances

Cemented Achromatic Doublets. Specifications & Tolerances Cemented Achromatic Doublets Cemented construction Focal lengths from 20 to 1000mm Diameters from 10 to 50.8mm Broadband Anti-Reflection coated These are cemented achromats with a very precise range of

More information

New Generation Explorer Handheld XRF. EXPLORER 7000 Mineral Ore Analyzer

New Generation Explorer Handheld XRF. EXPLORER 7000 Mineral Ore Analyzer New Generation Explorer Handheld XRF EXPLORER 7000 Mineral Ore Analyzer EXPLORER 7000 Mineral Ore XRF Based on ten-year research and development experience in Handheld X-Ray Fluorescense, Skyray Instruments

More information

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here Abstract This document describes how to install a StoreEver LTO Ultrium SAS internal tape drive and is intended for

More information

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com User Manual Binocular Stereo Microscope with Boom Stand Model W42C1 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 1 1. Component Illustration... 2 2. Installation...3

More information

SOLO an invisible, electronic lock with multiple usages STAND-ALONE ELECTRONIC RFID LOCK FOR:

SOLO an invisible, electronic lock with multiple usages STAND-ALONE ELECTRONIC RFID LOCK FOR: SOLO an invisible, electronic lock with multiple usages STAND-ALONE ELECTRONIC RFID LOCK FOR: Shops and Retail: Hospitals: Offices: Schools: Clubs: Glass cabinets and display cases, supply cupboards, staff

More information

To Our Valued Customers

To Our Valued Customers To Our Valued Customers ADC s Adview Modular Diagnostic Station provides a truly customizable diagnostic medical instrument. With your purchase of an Adview unit that includes a thermometry module, you

More information

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture HDAF800 HD 1080p Digital Microscope USB drive for Image Capture HDAF800-US Auto-Focus HD Camera System 1080p including Universal Stand with 15" Vertical Pole and integrated LED lighting and controls panels.

More information

SI-150-GIST. DART Thermo Quantiva, Endura, and Fusion VAPUR Interface User Manual. IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906

SI-150-GIST. DART Thermo Quantiva, Endura, and Fusion VAPUR Interface User Manual. IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 SI-150-GIST DART Thermo Quantiva, Endura, and Fusion VAPUR Interface User Manual Manual Revision 1 Document # 7.5.122 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright 2005-2015 by IonSense

More information

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About

More information

Laser Applications for Photovoltaics Crystalline and Thin Film Technologies

Laser Applications for Photovoltaics Crystalline and Thin Film Technologies LASERS & MATERIAL PROCESSING I OPTICAL SYSTEMS I INDUSTRIAL METROLOGY I TRAFFIC SOLUTIONS I DEFENSE & CIVIL SYSTEMS Laser Applications for Photovoltaics Crystalline and Thin Film Technologies Back contact

More information

SCXI-1345 Shielded Cable

SCXI-1345 Shielded Cable NATIONAL INSTRUMENTS The Software is the Instrument Installation Guide SCXI-1345 This guide describes how to install the SCXI-1345 shielded cable with an adapter board between an SCXI module and a data

More information

VINYL CUTTER C IV SERIES

VINYL CUTTER C IV SERIES VINYL CUTTER C IV SERIES EN CIV S E R I E S FEATURES 64 bit DC LITE Mac compatible USB Interface 64 bit compatible Plug & play LAPOS DrawCut LITE Cutting software VINYL CUTTER C IV SERIES Secabo s C IV

More information

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description Multifunctional housing for complex electronics Data sheet 105504_en_01 PHOENIX CONTACT 2013-04-08 1 Description The housings of the ME PLC 40... product group consist of a 40-mm wide housing base with

More information

User Manual. Confocal System

User Manual. Confocal System User Manual Confocal System 503301 - User Manual for the Confocal System Contents 1. Introduction... 3 2. Safety Summary... 3 3. Trademarks and Copyrights... 4 4. Contact Information... 4 5. Documentation

More information

See more with the NEW testo 880 thermal imager

See more with the NEW testo 880 thermal imager Committing to the future See more with the NEW testo 880 thermal imager NEW! SEE MORE......OFFER MORE. Infrared radiation cannot be seen by the human eye. All objects whose temperature is above absolute

More information

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE. TECHSPEC Optical Cage System

STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE. TECHSPEC Optical Cage System STEP-BY-STEP INSTRUCTIONS FOR BUILDING A FLUORESCENCE MICROSCOPE TECHSPEC Optical Cage System INTRODUCTION 2 What is a Digital Fluorescence Microscope? Unlike traditional microscopes, which utilize an

More information

Setting Standards. TOUCHSYSTEMS Made by HUMMEL. multitouch capacitive durable

Setting Standards. TOUCHSYSTEMS Made by HUMMEL. multitouch capacitive durable Setting Standards TOUCHSYSTEMS Made by HUMMEL multitouch capacitive durable TOUCHSYSTEMS - Made by HUMMEL TOUCHPANEL Made by HUMMEL MULTITOUCH Built in-panel 4 MULTITOUCH Standard-Panel 5 MULTITOUCH Design-Panel

More information

Precision Optics. Coating systems that think for themselves

Precision Optics. Coating systems that think for themselves Precision Optics Coating systems that think for themselves Coating systems that think for themselves Achieve maximum yields for even the most complex optical stack designs using real time re-optimisation

More information

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858)

KM6-II Subracks. APW Electronic Solutions. 152 APW Electronic Solutions Toll Free (800) Fax: (858) KM6-II Subracks Fully compatible with DIN41494 part 5 and IEC60297-3. KM6-II Standard is available in kit form, offering quick and simple assembly. KM6-II Universal is a highly versatile subrack system,

More information

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

1551 S. Harris Court,. Anaheim, CA Phone: Fax: 1551 S. Harris Court,. Anaheim, CA 92806 Phone: 714.978.1551... Fax: 714.978.0431 Model 4KE / 4KEH Series: Semi-Automatic, Motorized Y/Z Axes, Wedge-Wedge, Ball- Wedge Triple-Convertible Wire Bonders Last

More information

LOCKING RECONSTRUCTION AND MINI PLATE SYSTEM

LOCKING RECONSTRUCTION AND MINI PLATE SYSTEM LOCKING RECONSTRUCTION AND MINI PLATE SYSTEM Contourable in three dimensions BROCHURE LOCKING RECONSTRUCTION AND MINI PLATE SYSTEM Contourable in three dimensions 2.0 mm Mini Locking Plate and 2.4 mm Locking

More information

BENCHMIKE 283 SERIES. Off-Line ID/OD/Wall measurement systems for pipe and tube samples

BENCHMIKE 283 SERIES. Off-Line ID/OD/Wall measurement systems for pipe and tube samples BENCHMIKE 283 SERIES Off-Line ID/OD/Wall measurement systems for pipe and tube samples Measure manufactured parts or cut samples fast and with the highest accuracy Perform reliable, non-contact measurements

More information

ZUA 2000 Universal Applicator. Instruction manual

ZUA 2000 Universal Applicator. Instruction manual ZUA 2000 Universal Applicator Instruction manual Index Exclusion of liability... 4 1 Description of device... 5 2 Safety information... 5 2.1 Symbols used... 5 2.2 Safety notes and hints... 5 3 Delivery

More information

Service poles for industrial applications

Service poles for industrial applications Service poles for industrial applications Ready to go. The ISS basic profile Our industry service poles bundle power, data and compressed air in a compact and robust manner. This means relocations, for

More information

Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions

Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these

More information

SynJet PAR25 LED Cooler with Heat Sink

SynJet PAR25 LED Cooler with Heat Sink PRODUCT SynJet PAR25 LED Cooler with Heat Sink Assembly Guide Version 1.0 June 2009 Version History Document Name: SynJet PAR25 LED Cooler with Heat Sink Assembly Guide Document Number: MKTG-DOC-00048.

More information

Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions

Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions WARNING: READ ALL INSTRUCTIONS AND THE ENCLOSED SAFETY PRECAUTIONS BEFORE ASSEMBLY AND USE Assemble and use these parts ONLY

More information

Socket Mounting Recommendations and Reflow Profile

Socket Mounting Recommendations and Reflow Profile Purpose This document is meant to serve as a guide for mounting E-tec surface mount device (SMD) sockets to the printed circuit board (PCB). The recommendations described here are guidelines only, and

More information

System concept. Hardware DATA SHEET VECTRON POS TOUCH 12 II PCT

System concept. Hardware DATA SHEET VECTRON POS TOUCH 12 II PCT System concept The successor of the Vectron POS Touch 12 is even more powerful thanks to its new electronics and comes with a scratch-proof and wear-free capacitive glass touch screen. High-quality materials

More information

ETC. Source Four jr Zoom. Ellipsoidal Series. Source Four jr Zoom. Connector Designation

ETC. Source Four jr Zoom. Ellipsoidal Series. Source Four jr Zoom. Connector Designation S P E C I F I C A T I O N s PHYSICAL Rugged die cast aluminum construction 20 gauge stainless steel shutters in a bi-plane assembly High impact, thermally insulated knobs and shutter handles Two accessory

More information

LaserLyte-Flex Red & Green Alignment System

LaserLyte-Flex Red & Green Alignment System LaserLyte-Flex Red & Green Alignment System LaserLyte-Flex The LaserLyte-Flex is an entry-level laser alignment system. It uses interchangeable optics and a semiconductor laser diode to project a highly

More information

Advancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort

Advancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort Advancing Cancer Diagnostics Improving Lives Leica RM2235 The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort 2 As Durable as Ever, Enhanced Precision and Comfort Like Never

More information

SlicePlatform Fixed Platform System

SlicePlatform Fixed Platform System Experts in Electrophysiology & Imaging SlicePlatform Fixed Platform System Rock solid stability Mounting equipment www.scientifica.uk.com/sliceplatform 2 SlicePlatforms for upright microscopes Scientifica

More information

Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP (System Level ESD)

Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP (System Level ESD) Characterizing Touch Panel Sensor ESD Failure with IV-Curve TLP (System Level ESD) Wei Huang, Jerry Tichenor, David Pommerenke 2014 ESDA Exhibition Booth 606 Web: www.esdemc.com Email: info@esdemc.com

More information

Durable Metal IP66 Housing

Durable Metal IP66 Housing Durable Metal IP66 Housing Interchangeable Front IR Glasses Compatible with FLIR Ax5 cameras Brochure Workswell Fixed Housing for FLIR Ax5 cameras Workswell Fixed Housing is specially designed and manufactured

More information

F 470 LASER GLASS SCRIBER

F 470 LASER GLASS SCRIBER FANTOM LASER INSIDE F 470 LASER GLASS SCRIBER MODERN LASER TECHNOLOGY APPLICABLE FOR VIRTUALLY ANY PRECISION GLASS SCRIBING APPLICATION LCD'S, TN, STN, CSTN, TFT, PDP, VFD, E/L, OLED, FLCD, MD, PLED, LCOS

More information

STEP-BY-STEP INSTRUCTIONS FOR BUILDING AN AUTOCOLLIMATOR. TECHSPEC Optical Cage System

STEP-BY-STEP INSTRUCTIONS FOR BUILDING AN AUTOCOLLIMATOR. TECHSPEC Optical Cage System STEP-BY-STEP INSTRUCTIONS FOR BUILDING AN AUTOCOLLIMATOR TECHSPEC Optical Cage System INTRODUCTION 2 What is an autocollimator? The Autocollimator is a precision instrument composed of an achromatic objective,

More information

HEINE Binocular Loupes and Illumination Simplifying examinations for the most accurate diagnosis.

HEINE Binocular Loupes and Illumination Simplifying examinations for the most accurate diagnosis. HEINE Binocular Loupes and Illumination Simplifying examinations for the most accurate diagnosis. HEINE HR 2.5 x Binocular Loupes Fully customised magnification system for every application. FUNCTIONALITY

More information

Laserlyte Alignment System

Laserlyte Alignment System Laserlyte Alignment System A Global Laser Brand The LaserLyte alignment system is a unique, user adjustable, plug and play system suitable for a wide range of applications, i.e. alignment and these applications

More information

Coordinate Measuring Machines Catalog No. E16013

Coordinate Measuring Machines Catalog No. E16013 Manual Coordinate Measuring Machine MICROCORD M Series Coordinate Measuring Machines Catalog No. E16013 2 M: More quality, right down to the very last detail. M 3 All-in-all the most economical solution

More information