The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad160 is ideal for irradiating larger cell cultures and/or
|
|
- Prosper Logan
- 5 years ago
- Views:
Transcription
1 The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad160 is ideal for irradiating larger cell cultures and/or superficial small animal irradiation.
2 STOP Off On The MultiRad160 is a fully-shielded, self-contained x-ray irradiator that can be used almost anywhere, by anyone. There are no costly licensing, security, or source maintenance fees, providing a much lower total cost of ownership than radioisotope irradiators. Features & Benefits Contact us today! T +1 (203) E sales@pxinc.com No additional x-ray shielding required No specialized x-ray knowledge needed to operate Prescriptive, touchscreen control interface for ease-of-use Password login for system security Automatic warm-up and tube conditioning for extended tube life Electrically-operated turntable to ensure uniform dosing Integrated dosimeter with advanced Automatic Dose Control (ADC) for setting exact dose Interchangeable beam conditioning filters Port for ventilation and introducing auxiliary tubes and/or cables Fully integrated, closed-loop cooling system Remote diagnostics and support over the web Optional programmable motorized shelf for infinitely variable SSDs (manual adjustable shelf included) Optional imaging upgrade available with 23cm x 29cm high-resolution CMOS detector Optional Adjustable Collimator and Automatic Filter Selection Tested to meet US and International safety and electrical requirements Specifications Energy range Tube current at max voltage System power Dose rate (160kVp, 25mA) Focal spot size (EN 12543) Inherent filtration Beam angle Beam coverage up to 160kV 25mA 4000W up to 300Gy/min (unfiltered) up to 32Gy/min (2mm AI) up to 16Gy/min (0.3mm Cu) 5.5mm for irradiation 1.2mm (<0.5mm IEC) for imaging 0.8mm Beryllium 40 divergence 3.6 (9cm) (40cm) diameter cm / 77cm 188cm 35 / 88cm Source to sample distance Exposure time Power requirements Cooling Specimen turntable Chamber dimensions External dimensions Weight 5.2 (13cm) (65cm) programmable or continuous 220 VAC +/- 10 %, 50/60Hz, single phase, 7.5kVA integrated closed-loop heat exchanger electrically-operated, 2 RPM 23 H x 16 W x 17 D (58cm x 41cm x 43cm) 74 H x 43 W x 35 D (188cm x 108cm x 88cm) 2120lbs (960kg)
3 The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad225 is the perfect system for supplying higher dose to multiple, larger cell and tissue cultures and providing increased dose depth irradiation of small animals.
4 STOP Off On The MultiRad225 is a fully-shielded, self-contained x-ray irradiator that can be used almost anywhere, by anyone. There are no costly licensing, security, or source maintenance fees providing a much lower total cost of ownership than radioisotope irradiators. Features & Benefits Contact us today! T +1 (203) E sales@pxinc.com No additional x-ray shielding required No specialized x-ray knowledge needed to operate Prescriptive, touchscreen control interface for ease-of-use Password login for system security Automatic warm-up and tube conditioning for extended tube life Electrically-operated turntable to ensure uniform dosing Integrated dosimeter with advanced Automatic Dose Control (ADC) for setting exact dose Interchangeable beam conditioning filters Port for ventilation and introducing auxiliary tubes and/or cables Fully integrated, closed-loop cooling system Remote diagnostics and support over the web Optional programmable motorized shelf for infinitely variable SSDs (manual adjustable shelf included) Optional imaging upgrade availabe with 23cm x 29cm high-resolution CMOS detector (imaging limited to 160kVp) Optional Adjustable Collimator and Automatic Filter Selection Tested to meet US and International safety and electrical requirements Specifications Energy range Tube current at max voltage System power Dose rate (225kVp, 17.8mA) Focal spot size (EN 12543) Inherent filtration up to 225kV 17.8mA 4000W up to285gy/min (unfiltered) up to42gy/min (2mm AI) up to26gy/min (0.3mm Cu) 5.5mm for irradiation 1.2mm (<0.5mm IEC) for imaging 1.2mm Beryllium cm / 77cm 188cm 35 / 88cm Beam angle Beam coverage Source to sample distance Exposure time Power requirements Cooling Specimen turntable Chamber dimensions External dimensions Weight 40 divergence 3.6 (9cm) (40cm) diameter 5.2 (13cm) (65cm) programmable or continuous 220 VAC +/- 10 %, 50/60Hz, single phase, 7.5kVA integrated closed-loop heat exchanger electrically-operated, 2 RPM 23 H x 16 W x 17 D (58cm x 41cm x 43cm) 74 H x 43 W x 35 D (188cm x 108cm x 88cm) 2550lbs (1160kg)
5 The smaller, simpler, safer alternative to radioisotope irradiators. Precision s MultiRad350 is designed to deliver the highest dose with the most uniform depth. It is ideal for very dense biological specimens and a broad range of industrial applications.
6 STOP Off On The MultiRad350 is a fully-shielded, self-contained x-ray irradiator that can be used almost anywhere, by anyone. There are no costly licensing, security, or source maintenance fees providing a much lower total cost of ownership than radioisotope irradiators. Contact us today! T +1 (203) E sales@pxinc.com Features & Benefits No additional x-ray shielding required No specialized x-ray knowledge needed to operate Prescriptive, touchscreen control interface for ease-of-use Password login for system security Automatic warm-up and tube conditioning for extended tube life Electrically-operated turntable to ensure uniform dosing Integrated dosimeter with advanced Automatic Dose Control (ADC) for setting exact dose Interchangeable beam conditioning filters Port for ventilation and introducing auxiliary tubes and/or cables Fully integrated, closed-loop cooling system Remote diagnostics and support over the web Optional programmable motorized shelf for infinitely variable SSDs (manual adjustable shelf included) Optional fixed or adjustable beam collimators Optional automatic filter selection Tested to meet US and International safety and electrical requirements Specifications Energy range Tube current at max voltage System power Dose rate (225kVp, 17.8mA) Focal spot size Inherent filtration Beam angle up to 350kV 11.4mA 4000W up to 140Gy/min (unfiltered) up to 40Gy/min (1.2mm Cu HVL) up to 17Gy/min (4.0mm Cu HVL) 8mm 3mm Beryllium 40 divergence cm / 77cm 188cm 35 / 88cm Beam coverage range Source to sample range Exposure time Power requirements Cooling Specimen turntable Chamber dimensions External dimensions Weight 3.6 (9cm) (40cm) diameter 5.2 (13cm) (65cm) programmable or continuous 220 VAC +/- 10 %, 50/60Hz, single phase, 7.5kVA integrated closed-loop heat exchanger electrically-operated, 2 RPM 23 H x 16 W x 17 D (58cm x 41cm x 43cm) 74 H x 43 W x 35 D (188cm x 108cm x 88cm) 3470lbs (1575kg)
O-ARM IMAGING SYSTEM TECHNICAL SPECIFICATION GUIDE
IMAGING SYSTEM TECHNICAL SPECIFICATION GUIDE SYSTEM FEATURES CATEGORY PHYSICAL DIMENSIONS IMAGING MODALITY PERFORMANCE SPECIFICATION Length Width Height Weight Gantry Opening Bore Diameter Single Plane
More informationDX-D 100 with WITH ITS EXCELLENT IMAGE QUALITY AND
M O B I L E D R S O L U T I O N DX-D 100 with wireless detector Patients who most need imaging exams may lack the mobility necessary to move to the X-ray room or to position themselves properly for optimum
More informationFujifilm DR Solution. FDR AcSelerate. The new pinnacle in diagnostic imaging from Fujifilm ISS. CsI. Dynamic Visualization. Technology.
Fujifilm DR Solution FDR AcSelerate The new pinnacle in diagnostic imaging from Fujifilm CsI Scintillator ISS Technology Dynamic Visualization Welcome to the X-ray room of the future! A streamlined solution
More informationDX-D 100 with wireless detector
M O B I L E D R S O L U T I O N DX-D 100 with wireless detector Patients who most need imaging exams may lack the mobility necessary to move to the X-ray room or to position themselves properly for optimum
More informationDX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300
DX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM MUSICA processing provides excellent contrast detail and exam-independent, consistent image quality Cesium Iodide DR detector technology offers potential for
More informationDX-D 300. Flexible Direct Radiography System
DX-D 300 Flexible Direct Radiography System MUSICA 2 processing provides superior contrast detail and exam-independent, consistent image quality Cesium Iodide DR detector technology offers potential for
More informationLAMBDA DATA SHEET. ANALOGIC mammography unit. ANALOGIC mammography unit. Rev. n.05 of 15/01/13
NOTE The manufacturer reserves the right to make further improvements while keeping main features unchanged MAIN CHARACTERISTICS Line voltage 220/230/240 VAC 10% @ 50/60 Hz Power 6.6 kva (0.5 kva stand-by)
More informationZ-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL
Control-X Medical Z-MOTION Compact design, low ceiling height requirement Motorized and manual movement capability Wide motion / SID range Best-in-class image quality Flexible connectivity to PACS systems
More informationFLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300
FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300 The DX-D 300 DR system unites excellent image quality with complete convenience. It offers top-of-the-line technology, a single detector and a fully-motorized
More informationPROVIDE A UNIFORM DOSE IN THE SMALL ANIMAL.
Considerations in the Use of the RS 2000 X ray Irradiator for Biological Research (Primarily Small Animal, tissue, and cells) and the fallacy of the High KV spectrum. The performance goal for a small animal
More informationDX-D 100 WITH WIRELESS DETECTOR
DX-D 100 WITH WIRELESS DETECTOR MOBILE DR SOLUTION WITH ITS EXCELLENT IMAGE QUALITY AND FLEXIBLE HANDLING, THE MOBILE DX-D 100 WITH WIRELESS DETECTOR OFFERS FAST IMAGING THAT CAN BE VALIDATED IMMEDIATELY.
More informationDose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them
Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them
More informationProduct data. Mammographic System
Technologically advanced mammographic system, offering the best quality/price ratio. Lightweight and easy-to-use, facilitating the operator s job. Excellent diagnostic image quality, similar to the top-of
More informationDX-D 300. Flexible Direct Radiography System
DX-D 300 Flexible Direct Radiography System MUSICA² processing provides outstanding contrast detail and consistently excellent image quality Universal, flexible and affordable modality combines a single
More informationDX-D WITH DX-D 40/45 DETECTOR FAMILY MOBILE DR SOLUTION
DX-D 100 + WITH DX-D 40/45 DETECTOR FAMILY MOBILE DR SOLUTION WITH ITS EXCELLENT IMAGE QUALITY AND FLEXIBLE HANDLING, THE MOBILE DX-D 100 + WITH WIRELESS DETECTOR OFFERS FAST IMAGING THAT CAN BE VALIDATED
More informationPLANMECA PROMAX 3D MID CBCT UNIT
1(5) PLANMECA PROMAX 3D MID CBCT UNIT Introduction The Planmeca ProMax 3D Mid X-ray unit uses cone beam computerized tomography (CBCT) to produce three-dimensional X-ray images. Panoramic and cephalometric
More informationDX-D 800 DX-D 800 DYNAMIC, 3-IN-1 DIRECT RADIOGRAPHY SYSTEM OFFERING REAL TIME IMAGES FOR FLUOROSCOPY, GENERAL RADIOGRAPHY AND DIRECT EXPOSURES.
D I R E C T R A D I O G R A P H Y S Y S T E M DX-D 800 The DX-D 800, part of Agfa HealthCare s family of Direct Radiography (DR) solutions, provides enhanced flexibility in diagnostics through its direct
More informationDX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM DX-D 300 DR SYSTEM
DX-D 300 FLEXIBLE DIRECT RADIOGRAPHY SYSTEM The DX-D 300 DR system unites excellent image quality with the ultimate convenience. It offers top-of-the-line technology: a fullymotorized positioner enabling
More informationPORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL
HF80/15+DLP PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0 CONTENTS PAGE NO. NOTICE FOR SAFE OPERATION 2 INTRODUCTION... 3 NOTES TO USERS. 3 COMPONENTS.. 4 OPERATING CONDITIONS. 5 MAIN
More informationMobile X-Ray System C504-E025
Mobile X-Ray System C504-E025 The Advent of an Advanced Mobile System Featuring Superb Image Quality and Easy Handling Modern medical facilities require rapid examinations under a variety of situations.
More informationPlanmeca ProMax 3D s CBCT unit
D0010759 1(5) Planmeca ProMax 3D s CBCT unit Introduction The Planmeca ProMax 3D s X-ray unit uses cone beam computerized tomography (CBCT) to produce threedimensional X-ray images. Panoramic and cephalometric
More informationPlanmeca ProMax 3D Max CBCT unit
D00107623 1(6) Planmeca ProMax 3D Max CBCT unit Introduction The Planmeca ProMax 3D Max X-ray unit uses cone beam computerized tomography (CBCT) to produce threedimensional X-ray images. Panoramic and
More informationRaySafe Solo. Specifications
RaySafe Solo Specifications RAYSAFE SOLO GENERAL EMC TESTED According to EN 61000-6-1:2007 and EN 61000-6-3:2007 EXPOSURE NEEDED One RESET Automatic TEMP. 15 35 C (59 95 F) DETECTOR CABLE LENGTH 2 and
More informationC504-E013A. Mobile X-Ray System A-NS
C504-E013A Mobile X-Ray System 6295-11902-30A-NS The Advent of an Advanced Mobile System Featuring Superb Image Quality and Easy Handling Modern medical facilities require rapid examinations under a variety
More informationSpiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA
Spiral CT Protocol Optimization & Quality Assurance Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Protocol optimization
More informationExactly tailored to your demands.
CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS HELIODENT Plus EASY INTRAORAL X-RAYING Exactly tailored to your demands. T h e D e n t a l C o m p a n y Above all, the X-ray
More informationFischerscope X Ray CIRCULARS 07/01
Fischerscope X Ray CIRCULARS 07/01 New instrument Fischerscope X-Ray XDVM-P As we informed in December, both the instruments Fischerscope X-RAY XDVM-T7-W 602-636 (measuring head 602-557) and Fischerscope
More informationproduct data Raybow dr mobile digital radiographic system with wireless detector product data
Raybow dr mobile digital radiographic system with wireless detector Integrating all the advanced technologies, the ergonomic and high quality system Raybow dr lets you perform digital radiographies anywhere:
More informationIndustrial X-Ray Generators. Industrial X-Ray Tube Assemblies. Industrial X-Ray Tube Accessories. Generators. Controller. Generator tube combinations
Industrial X-Ray Generators Industrial X-Ray Tube Assemblies Industrial X-Ray Tube Accessories Generators Controller Generator tube combinations Your benefit Industrial x-ray generators from COMET offer
More informationFuture Topics. Projection Imaging Dose Reporting, XA 3D Volume Objects. for DICOM WG-02. Presented by Heinz Blendinger, Siemens Medical Solutions
Future Topics for Projection Imaging Dose Reporting, XA 3D Volume Objects DICOM WG-02 Presented by Heinz Blendinger, Siemens Medical Solutions 1 Presentation outline Dose Reporting Why Dose Reporting?
More informationShielding factors for traditional safety glasses
Shielding factors for traditional safety glasses Malcolm McEwen, Hong Shen and Ernesto Mainegra-Hing Ionizing Radiation Standards, National Research Council Canada Alan DuSautoy, Radiation and Health Sciences
More informationGET MORE OUT OF X-RAYS A thousand applications, one solution
GET MORE OUT OF X-RAYS A thousand applications, one solution INNOVATIVE LIGHT USER-FRIENDLY SAFE Our mission, at TELEDYNE ICM, is to facilitate professionals lives by providing innovative, user-friendly,
More informationPhoton beam dose distributions in 2D
Photon beam dose distributions in 2D Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2014 Acknowledgments! Narayan Sahoo PhD! Richard G Lane (Late) PhD 1 Overview! Evaluation
More informationXRAY SHARK xpb X-ray Scanner for transformer paperboards
XRAY SHARK xpb X-ray Scanner for transformer paperboards Introduction Generator Collimator Beam Detector XRAY SHARK - The Better Solution The XRAY SHARK is an x-ray device which is to be integrated in
More informationtr dent 2D-3D-PAN-CEPH
tr dent 2D-3D-PAN-CEPH X-VIEW evolves and develops in response to your needs 2D PAN 2D-PAN-CEPH Single Shot 3D-PAN Multilayer 3D-PAN Multilayer CEPH Single Shot Cone Beam 3D Multilayer 2D Panoramic 24
More informationLorad FFDM QC Procedures for Medical Physicist. Tao Wu, Ph.D. Hologic, Inc.
Lorad FFDM QC Procedures for Medical Physicist Tao Wu, Ph.D. Hologic, Inc. Lorad Selenia FFDM Tests Following Lorad QC Manual Collimation Assessment Artifact Evaluation System Resolution Phantom Image
More informationA SYSTEM OF DOSIMETRIC CALCULATIONS
A SYSTEM OF DOSIMETRIC CALCULATIONS INTRODUCTION Dose calculation based on PDD and TAR have Limitations The dependence of PDD on SSD Not suitable for isocentric techniques TAR and SAR does not depend on
More informationSOLAR LIGHTLINE SERIES
Features Meets Class AAA ASTM standards Fiberized output for flexible illumination. Easy-to-use touchscreen controls Light intensity control is available Remote control by PC Cost-effective for researchers
More informationFits you like no other
Fits you like no other BrightView X and XCT specifications The new BrightView X system is a fully featured variableangle camera that is field-upgradeable to BrightView XCT without any increase in room
More information& Superior Image Quality Seamlessly Compatible with EVA-Vet Digital Dental Sensors Thousands of installations and growing Customer Care Program www.imageworkscorporation.com ImageWorks Generations of Imaging
More informationräíê~_êáöüí Microfocus X-Ray Source Technical Data Sheet X-Ray Tube Unit Specifications
Technical Data Sheet räíê~_êáöüí 4 mm Anode to Object distance True round spot Grounded target = High power, 80W Integrated design No HV cable The choice for use with an x-ray optic due to close coupling
More informationDX-D 600 DX-D 600 HIGH-PRODUCTIVITY, EXCELLENT IMAGE QUALITY, DIRECT RADIOGRAPHY SYSTEM WITH STATE-OF-THE-ART DESIGN IN THREE CONFIGURATION OPTIONS.
D i r e c t r a d i o g r a p h y s y s t e m DX-D 600 HIGH-PRODUCTIVITY, EXCELLENT IMAGE QUALITY, DIRECT RADIOGRAPHY SYSTEM WITH STATE-OF-THE-ART DESIGN IN THREE CONFIGURATION OPTIONS. Two-detector, high-productivity,
More informationSNOQUALMIE VALLEY HOSPITAL DISTRICT REQUEST FOR INFORMATION FOR X-RAY PORTABLE EQUIPMENT Ethan Wade Way SE Snoqualmie, WA 98065
SNOQUALMIE VALLEY HOSPITAL DISTRICT REQUEST FOR INFORMATION FOR X-RAY PORTABLE EQUIPMENT 9575 Ethan Wade Way SE Snoqualmie, WA 98065 TABLE OF CONTENTS PAGE I. INTENT... 1 II. BACKGROUND... 1 III. SCOPE...
More informationCUBE. Diode Laser System. Superior Reliability & Performance
Features Compact and modular OEM design Complete CDRH safety features for scientific and laboratory use TEC temperature-stabilized and conductively cooled through baseplate Analog and digital modulation
More informationLASER CUTTER LASER CUTTER VS. OTHER TOOLS LASER CUTTER CREATE & EXPAND YOUR PROJECT PORTFOLIO
CREATE & EXPAND YOUR PROJECT PORTFOLIO Bridging the tradition of making with the future of digital creation, Dremel DigiLab Laser Cutter adds a new edge to your projects. Whether you re creating custom
More informationIntroduction to Biomedical Imaging
Alejandro Frangi, PhD Computational Imaging Lab Department of Information & Communication Technology Pompeu Fabra University www.cilab.upf.edu X-ray Projection Imaging Computed Tomography Digital X-ray
More informationAdaptable Full-Color LED DMX Luminaire
TRIUMPH TR30 Adaptable Full-Color LED DMX Luminaire The Luxium TM TR30 is a unique LED lighting fixture with a DMX control system that merges an innovative high-output lighting module using 12 multi-color
More informationXSIMA X-RAY EQUIPMENT
ISO13485 Certified XSIMA X-RAY EQUIPMENT Portable X-ray Machine Mobile X-ray Machine Conventional X-ray Machine High Frequency X-ray Machine Digital X-ray Machine Veterinary X-ray Machine Join Star Business
More informationFits you like no other
Fits you like no other Philips BrightView X and XCT specifications The new BrightView X system is a fully featured variableangle camera that is field-upgradeable to BrightView XCT without any increase
More informationUser Manual Shutter (T6801) and filter wheel (L981054) D / Sa
User Manual Shutter (T6801) and filter wheel (L981054) D780.131.0/0 2004-11 Sa General Information General Information The product bears the CE-mark "CE" in accordance with the Council Directive 98/37/EC
More informationSetup and Instruction Manual
Setup and Instruction Manual NOMAD SPECIFICATIONS: Type Motor Belt drive (manual turntable) 24 VAC Synchronous AC Motor Turntable Platter Diameter Turntable Speeds Wow and Flutter Rumble Machined MDF 11.81"
More informationREXTAR Exo Ultimate Portable X-ray System
REXTAR Exo 1414 Ultimate Portable X-ray System Contents Company Introduction Special Features Overview Specifications How To Use Package Posdion Co., Ltd. About US Posdion Co., Ltd. is specialized in handheld
More informationAs flexible and individual as your practice.
Intraoral imaging instruments treatment centers Imaging systems cad/cam systems XIOS PLUS - INTRAORAL SENSOR HELIODENT Plus - INTRAORAL X-RAY SOURCE As flexible and individual as your practice. XIOS PLUS
More informationSUMMARY OF DENTAL MEASUREMENT PROCEDURES (Abridged Protocol)
SUMMARY OF DENTAL MEASUREMENT PROCEDURES (Abridged Protocol) INTRAORAL IMAGING PROCEDURE Entrance Skin Exposure / Air Kerma To measure the typical intraoral Entrance Skin Exposure (ESE) and Entrance Skin
More informationStingRay and BioRay FEATURES
StingRay and BioRay Coherent s high-performance laser in a compact module, measuring only 19 mm in diameter, is the StingRay and BioRay product families. Modular design using the industries premier laser
More informationUltra High Vacuum Pumps
Ultra Hig Ultra High Vacuum Pumps TiTan TM Ion Pumps BOOSTIVAC TM Titanium Sublimation Pumping (TSP) Non-evaporable Getter (NEG) DIGITEL TM Ion Pump Controllers 310.00.02 Excerpt from the Leybold Full
More informationDAILY LINAC QA BEAM QA
BEAM QA DAILY LINAC QA The QA BeamChecker Plus allows for fast, reliable, and uncomplicated daily QA of Varian, Elekta, Siemens, and Accuray Treatment Machines. The QA BeamChecker Plus is specifically
More informationSolid Capabilities Are Built Into the Supria Plus. Putting You On The Path of High Quality, Cost-Effective CT Scanning
Specification Data Putting You On The Path of High Quality, Cost-Effective CT Scanning Solid Capabilities Are Built Into the Supria Plus Addressing the challenges of controlling healthcare organization
More informationspecifications Acuity ix The next dimension in treatment planning, simulation, and verification
specifications Acuity ix The next dimension in treatment planning, simulation, and verification Acuity ix Acuity ix is a fully integrated digital imaging device that includes all features necessary for
More informationRadiation Oncology treatment facility design. Simulators, CT scanners, HDR Brachytherapy
Radiation Oncology treatment facility design Simulators, CT scanners, HDR Brachytherapy McGill MDPH 613 Fall 2004 UNITS For this class only: 1 R = 1 cgy = 1 csv = 10 msv Reference book McGinley NCRP 49
More informationTEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units
Hounsfield units TEP Related topics Attenuation coefficient, Hounsfield units Principle Depending on the type of CT scanner and the settings, the result of a CT scan of the same material can be different
More informationION BEAM MILLING SYSTEM FOR TEM, SEM AND LM PREPARATION. Leica EM RES102
ION BEAM MILLING SYSTEM FOR TEM, SEM AND LM PREPARATION Leica EM RES102 ION BEAM MILLING In recent years, ion milling has been developed into the most applicable method of sample preparation for the analysis
More informationHybrid. powered. 20BT lite / 20BT / 40BT. 20 lite / 60. Model mex+20bt lite mex+20bt mex+40bt. Model mex+20 lite mex+20 mex+40 mex+60 mex+100
20BT lite / 20BT / 40BT 20 lite 20 Hybrid powered 40 / 60 Model mex+20bt lite mex+20bt mex+40bt Output Tube Vol. / Current 90 kv / 20 ma 100 kv / 20 ma 100 kv / 35 ma Voltage range 50-90 kv in 1 kv steps
More informationThermo Scientific IEC CL30 Centrifuge Series Convenience, Reliability and Value
Thermo Scientific IEC CL30 Centrifuge Series Convenience, Reliability and Value Featuring Fast Rotor Exchanges with AUTO-LOCK Thermo Scientific IEC CL30 Centrifuge Series Convenience, Reliability and Value
More informationWolf Laboratories Limited
Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on
More informationDICOM Correction Item
DICOM Correction Item Correction Number CP-776 Log Summary: Type of Modification Correction Name of Standard PS 3.3 2007 Rationale for Correction For some time it has been the convention not to make attributes
More informationLoad Transfer Panels. CTI Range: Amps ATI Range: Amps
Load Transfer Panels CTI Range: 63 160 Amps ATI Range: 250 3200 Amps Load Transfer Panels Providing automatic control of your standby generating set in the event of a power outage, 24 hours a day, 365
More informationBrillant 285 WET ABRASIVE CUT-OFF MACHINES
The industrial wet cut-off machine meets the highest of demands on space available and possibilities for cutting with its innovative concept for design, construction and operation. A water-cooled 15 kw
More informationPower Wave 455M Robotic & Power Wave 455M/STT Robotic
Power Wave 455M Robotic & Power Wave 455M/STT Robotic AUTOMATED SOLUTIONS The Next Generation... The Power Wave 455M Robotic & 455M/STT Robotic are high performance, digitally controlled inverter welding
More informationPCXMC 2.0 SUPPLEMENTARY PROGRAMS USER'S GUIDE
FEBRUARY 2012 PCXMC 2.0 SUPPLEMENTARY PROGRAMS USER'S GUIDE PCXMC20Rotation.exe Autocalc-sheet.xls AutocalcRotation-sheet.xls Markku Tapiovaara STUK - Radiation and Nuclear Safety Authority P.O. Box 14
More informationPRODUCT DATA. Advanced 128
PRODUCT DATA Advanced 128 Supria 16 Slice CT Puts You On The Path of High Quality, Cost-Effective CT Scanning Solid Capabilities Are Built Into the Supria Addressing the challenges of controlling healthcare
More informationTHE EASE OF MOBILE X-RAY TECHNOLOGY
THE EASE OF MOBILE X-RAY TECHNOLOGY THE EASE OF MOBILE X-RAY TECHNOLOGY The feather belongs to nature s most brilliant solutions. It sustains and yields warmth, providing an elegant design. Close to nothing
More informationFinancial disclosure. Onboard imaging modality for IGRT
Tetrahedron Beam Computed Tomography Based On Multi-Pixel X- Ray Source and Its Application in Image Guided Radiotherapy Tiezhi Zhang, Ph.D. Advanced X-ray imaging Lab Financial disclosure Patent royalty
More informationENDOS AC / ACP Service Manual. (120V version) Release 17 July 2013 (Rev. 7)
ENDOS AC / ACP 0051 (120V version) Service Manual Release 17 July 2013 Revision history Revision history Manual code 6961902103 Rev. Date Page/s Modification description 0 02.04.03 - Document approval.
More informationImmunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl. Cat.-No. capillaries per rotor
CENTRIFUGES BOECO HEMATOCRIT CENTRIFUGE H-240 High-speed bench-top centrifuge for microhematocrit determinations with brushless frequency drive. At 16.060 g sedimentation is completed in just a little
More informationUser Manual. Cobia Flex R/F English - v2016.5a
User Manual Cobia Flex R/F English - v2016.5a NOTICE RTI Electronics AB reserves the right to make changes to the Cobia Flex R/F and the information in this user manual without prior notice. RTI Electronics
More informationBecause Frozen Sections are Vitally Important
The Pathology Company Because Frozen Sections are Vitally Important Leica CM1860/CM1860 UV high-throughput clinical cryostat with AgProtect (with and without UV Protection) 2 3 Confidence is Vital Safety
More information»»»LASER GENERATION IV The Innovation for your Success
»»»LASER GENERATION IV The Innovation for your Success VISION LWI IV FIBER FLE X X FLEXABILITY FOR NEW POSSIBILITYS Based on the well-established and reliable LWI IV Series the Fibre Fle x x is the choice
More informationGenesis CX SLM-Series
Genesis CX SLM-Series Single Frequency UV and Visible OEM and End-User OPS Laser Systems Applications such as spectroscopy, interferometry, and holography require single-frequency lasers with narrow linewidths
More informationCentrifuges 5702/ 5702 R/ 5702 RH
196 Sample Handling 5702/ 5702 R/ 5702 RH The 5702 family of low speed, general purpose centrifuges was especially designed to meet the requirement of low- to midthroughput clinical research and cell culture
More informationQuick-Start. Installation: NOTE: Install Accu-Gold Excel before connecting the Accu-Gold digitizer to a USB port.
Accu-Gold Excel Plus Templates version 8.10.0009 Quick-Start Overview: Accu-Gold Excel Plus Templates is an Excel interface for Radcal s Accu-Gold measurement system. Microsoft Excel for W indows is required,
More informationSurgical Lights. M-Series Surgical Lighting System
Surgical Lights M-Series Surgical Lighting System Pure, white brilliance Experience the clear difference in coolness, comfort and natural color rendition inherent in pure, white LED light. STERIS s M-Series
More informationEXPLOR-X 70. Service manual. with AP TIME X TIME X timer (120V version) Release 16 March 2001 (Rev. 1)
EXPLOR-X 70 with AP TIME X TIME X timer (120V version) Release 16 March 2001 Service manual Contents Contents 1. INTRODUCTION 1 1.1 Icons appearing in the manual... 1 2. SAFETY INFORMATION 2 2.1 Warnings...
More informationImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing
ImPACT Information Leaflet No. 1: CT Scanner Acceptance Testing Version 1.02, 18/05/01 CONTENTS: 1. SCOPE OF LEAFLET 2. GENERAL PRINCIPLES OF ACCEPTANCE AND COMMISSIONING 2.1 PHANTOMS 2.2 EXPOSURE AND
More informationSTORAGETEK SL150 MODULAR TAPE LIBRARY
STORAGETEK SL150 MODULAR TAPE LIBRARY Oracle s StorageTek SL150 modular tape library is the first scalable tape library designed for growing businesses. Built from Oracle software and StorageTek library
More informationComputed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system
Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination
More informationWinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, * nm * model-dependent
Datasheet WinCamD-LCM 1" CMOS Beam Profiling Camera, SuperSpeed USB 3.0, 190 1610* nm * model-dependent With an 11.3 x 11.3 mm active area, 4.2 Mpixels, 5.5 x 5.5 μm pixels, optical and electronic triggering
More informationL CV1050 Constant Voltage LED Driver, 24Vdc, 25W L1K1MID024V-25E
L05032-24CV1050 Constant Voltage LED Driver, 24Vdc, 25W L1K1MID024V-25E Engineered for Best Fixture Performance Fulham LumoSeries LED drivers are designed to efficiently power and control LED solutions
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationWHEATON. Roller Apparatus R2P 2.0 and the WHEATON Standard Roller for Adherent Cell Culture. The First Single Use Bioreactor.
WHEATON Roller Apparatus R2P 2.0 and the WHEATON Standard Roller for Adherent Cell Culture > 2 R2P WHEATON Roller Apparatus 2.0 and the WHEATON Standard Roller for Adherent Cell Culture We have updated
More informationIS-3000-LS-ABB INFRARED SCANNER
IS-3000-LS-ABB INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES: SIMULATES ORIGINAL ABB PULSE OUTPUT AUTOMATIC GAIN CONTROL ADJUSTABLE SCAN ANGLE
More informationXRF for Regulatory Programs RoHS and Consumer Safety Compliance
Compact X-ray Fluorescence Xpert XRF for Regulatory Programs RoHS and Consumer Safety Compliance RoHS CPSIA EN71-3 Proposition 65 The Xpert for Regulatory Programs Consumer Safety and RoHS Compliance The
More informationCat. No. Description Tube Capacity Speed Range Rocking Angle Exterior Shipping Electrical
Vari-Mix and Speci-Mix Test Tube Rockers Compact, precision-controlled platform mixers provide smooth rocking action for uniform specimen suspension All models hold 10 to 30mm diameter tubes and are ideal
More informationTiTan Ion pumps (MINI - 75S) (100L LX) (150TV - 600TV)
Titan ion pumps TiTan Ion pumps TiTan Ion pumps Ion pumps are used in a wide variety of high and ultra-high vacuum (UHV) environments. They can reach the lowest possible vacuum for an economical cost.
More informationGLP German Light Products GmbH
GLP German Light Products GmbH Copyright GLP German Light Products GmbH. All rights reserved. Technical data is subject to be changed without notice. /GLP.German.Light.Products /GLPimpression www.glp.de
More informationMedical X-ray Imaging
Medical X-ray Imaging HYBRID PORTABLE X-RAY 20BT lite / 20BT / 40BT The world s only hybrid powered portable X-ray Light weight, compact size and durable cover Light weight portable X-ray with high power
More informationSpecification Data Sheet
Specification Indoor Light : T8T Series Standard Standard Specification Data Sheet T8 Series ( Standard ) Product Picture : T8T-4ft Features 3 Years Warranty Specified Beam Angle CE / UL / DLC / RoHS Certificated
More information4000 SERIES REGULATED HIGH VOLTAGE DC TO DC CONVERTERS
Proven Reliability 4000 SERIES REGULATED HIGH VOLTAGE DC TO DC CONVERTERS 1,000 V to 33,000 VDC @ 10 Watts PRODUCT SELECTION TABLE PRODUCT DESCRIPTION The 4000 Series is a line of fully adjustable DC to
More informationThermo Scientific IEC CL31 Multispeed Centrifuge Series Maximum Versatility, Exceptional Capacity and Performance
Thermo Scientific IEC CL31 Multispeed Centrifuge Series Maximum Versatility, Exceptional Capacity and Performance Featuring Fast Rotor Exchanges with AUTO-LOCK Thermo Scientific IEC CL31 Multispeed Centrifuge
More informationMedical X-ray Imaging
Medical X-ray Imaging HYBRID PORTABLE X-RAY 20BT lite / 20BT / 40BT The world s only hybrid powered portable X-ray Light weight, compact size and durable cover Light weight portable X-ray with high power
More information