1 Data sheet 6852 Page 1/11 Contact Dial Thermometers FL 21 Special features Class 1.5 Display range -4 C to +6 C Temperature controller with actual value display as built-in or add-on device in a stainless steel case with 1 or 2 microswitches Case sizes : 6 mm, 8 mm, and 1 mm Front panel: 72x72 mm and 96x96 mm Brief description Contact dial thermometers are devices with an actual value display for temperature measurement, control, and monitoring and can be used universally. The temperature-dependent volume change in a measuring system filled with liquid or the temperature-dependent pressure change in a measuring system filled with gas is converted to a rotational movement of the actual value indicator by a bourdon tube; no transmission gear is required. The microswitch is actuated by the rotational movement of the indicator shaft via a tap system. Type 6852/238 Contact dial thermometers in the series 6852 are RoHS-compliant and cadmium-free. Technical data Type 6855/18 Case and front panel Stainless steel (1.431) Cover cap Plastic (PA6), gray, UV-stabilized Protection type IP 54 according to DIN EN 65 Front pane Acrylic glass (PMMA) Chassis Aluminum ( ) Scale White, with black lettering Display Class 1.5 similar to DIN EN 1319 Strain relief spring For capillary devices on the case and the temperature probe Setpoint value adjustment By setpoint adjuster in the front pane Display correction On the rear Limit value temperatures For transport and storage -3 C to +7 C (for display range -4 to +4 C up to max. 5 C; -3 to +5 C up to max. 6 C) Rated position (NL) Any
2 Data sheet 6852 Page 2/11 Technical data Display range (AB) Display range in C Measuring range in C Tolerance in K (+/-) to +4-3 to to to to to to to to to to to to to to to to to to to Liquid filling Gas filling Measuring system Display range (AB) 35 C Display range (AB) 4 C Time constant.632 Approx. 12 s, measured in water, with a probe Ø of 6 mm made of copper. Approx. 4 s, measured in oil, with a probe Ø of 1 mm made of stainless steel. Ambient temperature influence effect In % of the display range (referring to the deviation from the reference value +23 C) On case On capillary (per m).15% of the display range per K ambient temperature change.5% of the display range per K ambient temperature change.3% of the display range No influence per K ambient temperature change At higher ambient temperature higher temperature display lower switching point Standard Extra code (TZ) 65 Electrical contact Contact type Single-pole microswitch with mechanically actuated changeover contact Switching capacity AC 23V, +1/-15%, 48 to 63Hz, cos ϕ = 1 (.6) 5 (1.5) A 1 (3) A Switching differential Approx. 1.5% of the display range 1.5 to 3% of the display range Switching point accuracy ±.5% of the display range referring to the switch-off point with rising temperature Switching reliability To ensure a high switching reliability, we recommend a minimum voltage of 24 V and a minimum current of 1 ma Electrical connection Standard Design type 2 and 22 Design type 1, 23, and TZ 426 Screw terminals, connection cross-section up to 2.5 mm2 Connection cable.5 m with screw terminals Cover cap with cable fitting, suitable for cable Ø from 6.5 to 13 mm Case 6 mm Cover cap with cable fitting, suitable for cable Ø from 8 to 1 mm
3 Data sheet 6852 Page 3/11 Dimensions 6852/28 L S 42 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/21 Ø1 L S 42 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/18 44, ,5 L S ( 2 ) ( 2 ) Active probe dimension
4 Data sheet 6852 Page 4/ /11 44, ,5 S 4 Ø1 L ( 2 ) ( 2 ) Active probe dimension 6852/ Ø 6 Ø 65 3,6 3x 12 Ø 6 mm = 62 mm 6852/28 Ø11 Ø 95 Ø4, ,5 3x12 Ø 8 mm = 62 mm
5 Data sheet 6852 Page 5/ /21 Ø132 Ø116 Ø ,5 Ø4,8 3x12 Ø 1 mm = 1 mm 6852/ ,3 28 Ø65 Ø6 Ø 6 mm = 62 mm 6852/ ,5 Ø 8 mm = 62 mm 6852/ Ø1 16, Ø 1 mm = 1 mm
6 Data sheet 6852 Page 6/ /228 Ø Ø Ø4,8 3x12 45 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/221 Ø132 Ø Ø1 Ø4,8 3x12 45 ( 1 ) ( 1 ) Connecting cable.6 m long with screw terminal 6852/238 44, ,5 43 Ø7 5 ( 3 ) Spigot Ø 2 mm 8 ( 3 )
7 Data sheet 6852 Page 7/ /231 44, Ø1 ( 3 ) Spigot Ø 2 mm Ø7 5 8 ( 3 ) 6852/2572 H Ø6 27 Panel cut-out for front panel 72x72mm=Ø62 mm 6852/ ,3 22, Panel cut-out for front panel 96x96mm=Ø82 mm oder 96x96mm=92x92 mm (TZ 46)
8 Data sheet 6852 Page 8/11 Order details Order code ( 1 ) Basic type 6852 Mechanical contact dial thermometer, class Mechanical contact dial thermometer, class 1.5, transformer version (only basic type extension 18) ( 2 ) Basic type extension Case size Ø 28 Design type 2 8 mm 21 1 mm 18 Design type 1 8 mm 11 1 mm 26 Design type 2 6 mm 28 8 mm 21 1 mm 216 Design type 21 6 mm mm mm 228 Design type 22 8 mm mm 238 Design type 23 8 mm mm 2572 Design type 25 Case size x 72 mm 96 x 96 mm ( 3 ) Display range in C to to to to to to to to to to +6
9 Data sheet 6852 Page 9/11 Order code ( 4 ) Capillary type (FL) a Without (with rigid connection) 2 FL 2 Cu capillary with Cu textile braiding, approx. Ø 2.5 mm (up to AB end value +3 C) 11 FL 11 Cu capillary with PE coating, approx. ø 3.5 mm (up to AB end value +12 C) 17 FL 17 Stainless steel capillary, approx. Ø 1.5 mm 21 FL 21 Cu capillary, approx. Ø 1. mm (up to AB end value +3 C) ( 5 ) Capillary length b Without (with rigid connection) 1 1 mm 2 2 mm 3 3 mm 4 4 mm 5 5 mm.... Special length (specifications in plain text: 1, mm increments, maximum length 6, mm), additional lengths upon request ( 6 ) Process connection (PC) a 75 TF 1 Temperature probe with stepped support tube 752 TF 11 Temperature probe without support tube 843 TA 2 Protection tube with union nut and loose screw connection b 161 TA 3 Protection tube with loose screw connection 847 TA 6 Protection tube with displaceable threaded fitting on support tube b 311 TA 2 Protection tube with loose screw connection and connection collar b 872 TA 21 Protection tube with loose pressure screw and conical seal (only G 3/8 possible) 873 TA 22 Protection tube with loose pressure screw, conical seal, and loose screw connection b 874 TA 24 Protection tube (CuNi) with screw connection (CuZn), O ring seal and clamping screw a b 41 TA 23 Protection tube with pressure screw and contact pressure spring (only M 1x1 possible) 913 SH 7 Screw-in protection tube, multi-sectional, with clamping piece and fixing screw (suitable for TF 1 and TF 11) 82 SH 9 Weld-in protection tube, multi-sectional, with clamping piece and fixing screw b (not for FL 21 welding collar with steel ) 876 SH 1 Screw-in protection tube, multi-sectional b (suitable for TA 21) 871 SH 11 Screw-in protection tube, multi-sectional b (suitable for TA 23) a For the description and special features refer to data sheet b Screw-in spigot according to DIN 3852, form A.
10 Data sheet 6852 Page 1/11 Order code ( 7 ) Ø Process connection (PC) a 6 6 mm 8 8 mm 1 1 mm mm mm ( 8 ) Thread type of process connection (PC) a Without thread (for TA 1 and TF 11) 13 Screw connection G 3/8 14 Screw connection G 1/2 15 Screw connection G 3/4 114 Screw connection M 1 x 1 (only with TA 23) ( 9 ) Material, probe / support tube a 26 Stainless steel (CrNi, ) 96 Copper (Cu) / Brass (CuZn) (up to 2 C) 95 Stainless steel (CrNi, ) probe / brass (CuZn) support tube (from 25 C) ( 1 ) Material of process connection (PC) a Without (only TF 1 and TF 11) 26 Stainless steel (CrNi, ) 46 Brass (CuZn) ( 11 ) Insertion length, process connection (PC) a (dimension "EL" or "S") Minimum insertion length TF 11 (active probe dimension) 5 5 mm 1 1 mm mm 2 2 mm... Special length (specifications in plain text 5 mm increments) a For the description and special features refer to data sheet 6873.
11 Data sheet 6852 Page 11/11 Order code ( 12 ) Switching output 2 1 changeover switch 21 2 changeover switches 22 2 changeover switches in fixed sequence ( 13 ) Extra codes (TZ) Without extra code 426 Cover cap to protect the screw terminals against contact and spray water (standard for design types 1 and 23; not for design type 22; not in connection with TZ 46) 43 Drag indicator (includes TZ 477) 46 Device centering for panel cut-out mm (only for basic type extension 2596) 477 Setpoint adjustment protected by the bolted cover. Adjustment with screwdriver. 518 Stop for Min. or Max. setpoint value limitation, default setting 522 Customized scale 65 Microswitch 1 (3) A (AC/DC 23 V, +1/-15%, 48 to 63 Hz, cos ϕ = 1 (.6) ) Special versions upon request! Order code ( 1 ) ( 2 ) ( 3 ) ( 4 ) ( 5 ) ( 6 ) ( 7 ) ( 8 ) ( 9 ) (1) (11) (12) (13) 6852 / /...,... Order example 6852 / / 65 a,... a List extra codes in sequence, separated by commas. Stock versions Part no. Type Display range C / / with drag indicator / / with drag indicator Switching output Temperature probe, process connection Protection tube mm -2 to (1 contact) TF 5 d = 8 mm 21 TA 24, G 1", CuZn 15 (2 contacts) Delivery within 3 working days after receipt of order
Approx. 4 s, measured in oil, with a probe Ø of 10 mm made of stainless steel. Influential effect of the ambient temperature
sales@jumo.co.uk info.us@jumo.net Page/6 Dial Thermometer Type 608225 Special features Class Display ranges from -40 C to +600 C Temperature indicator as built-in or add-on device Stainless steel case
More informationDial Thermometer. Particularities. Brief description. Technical data. Page 1/6. Data Sheet
Dial Thermometer Data Sheet 608202 Page 1/6 - discontinued - Particularities Temperature indicator for panel mounting Class 2 IP53 front protection Housing sizes: 52 mm and 60 mm dia. Bezel: 48x48 mm,
More informationSurface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection
Page 1/6 Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection Brief description Surface-mounting thermostats control and monitor thermal processes. Thermostats
More informationGas-actuated thermometer Stainless steel version Model 73
Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical
More informationScrew-in resistance thermometers with terminal head Form B
Data Sheet 90.2002 Page 1/7 s with terminal head Form B for temperatures from -50 to +600 C with replaceable measuring insert as single or twin resistance thermometer terminal head Form B, BUZ, BUZH, BBK
More informationInsertion RTD temperature probe
Data sheet 902350 Page 1/6 For temperatures between -50 and +260 C Steam-tight and pressure-resistant High mechanical strength For use in the food industry Available with multiple measuring points Due
More informationTHERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA
Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure
More informationPush-in RTD temperature probes with terminal head form B
Data Sheet 90.2120 (90.2102) Page 1/5 with terminal head form B For temperatures from -50 to +600 C with replaceable measuring insert As single or double RTD temperature probes Connection head form B,
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.
More informationRTD insertion temperature probes
Data sheet 902350 Page 1/6 for temperatures from -50... +260 C Steam-tight and pressure-resistant High mechanical strength For use in the food industry Available with multiple measurement points Due to
More informationLS 5000 series Vibration Level Switch for liquids
Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.
More information14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page
Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03
More informationThreaded resistance thermometer Miniature design Model TR10-D
Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationselection of special materials is available to handle almost any fluid.
For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications
More informationM3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems
MP..G/A, MP..F/A Modulating control valves (PN) for chilled and hot water systems Three-way or straight-through valves with magnetic actuators for modulating control of chilled and hot water systems. Short
More informationPressure switches and thermostats, types KP and KPI
Features Wide regulating range Small dimensions Space-saving - easy to install in panels Ultra-short bounce time. Limits wear to an absolute minimum and increases reliability. Electrical connection at
More informationLevel Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75
Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded
More informationVandal-proof latching action switch MSM LA
Product Manual Vandal-proof latching action switch MSM LA CONTENTS 1 PRODUCT DESCRIPTION... 2 2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS... 2 2.1 Technical Data... 2 2.2 Dimensional Drawings... 5 2.3 Hole
More informationTemperature Measurement SITRANS TS300
Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø
More informationThreaded thermocouple Miniature design Model TC10-D
Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology
More informationMPreC - Pressure Relief Device Order specification sheet
- Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter
More informationBourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063
Mechatronic pressure measurement Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 WIKA data sheet PV 12.03 for further approvals see page
More informationResistance thermometer With spring-loaded tip Model TR55
Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationRoHS. High shaft load capacity. Shock / vibration resistant
Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up
More informationIncremental Encoder with Hollow Shaft
Incremental Encoder Type RI 36-H n miniature industry encoder for high number of pulses n short mounting length n easy mounting procedure n Application e.g.: - Motors - Machine tools - Packaging Machines
More informationLevel switch NS 10/NS 25..-AM
Level switch NS 10/NS 25..-AM Fluidcontrol Oil tanks in lubrication and oil supply systems are often under overpressure compared to the ambient atmosphere. All oil moistened parts of devices mounted externally
More informationThermocouples Model TC200, for Additional Thermowell
Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology
More informationCombiTemp Temperature Measuring System
CombiTemp Temperature Measuring ystem Flexible building block concept All wetted parts in acid-proof, stainless steel Pt or Pt sensors, - or -wire DIN A or B (/, /, /) elements ensor tubes Cable sensors
More informationBVS UR E Ordering code: BVS001H
BVS UR-3-101-E Ordering code: BVS001H Vision sensor BVS-E Universal PNP (2x) 1) Teach reference image, 2) Power, 3) Output 1 active, 4) Output 2 active, 5) Connection with PC, 6) Sharpness Characteristic
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
Data Sheet 4000 Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description
More informationFloat Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65
Float Flow Meter Flow measurement for translucent liquids and gases DN10 to DN65 mm If a medium sufficient flow rate flows from bottom to top through a vertically inserted measuring tube, then the floated
More informationنﺎﻤﻟ آ ﻲﻧﺎﭙﻤﻛ يرﺎﺼﺤﻧا هﺪﻨﻳﺎﻤﻧ
ا زما صنعت گراد Mahr - your stable partner for manufacturing. Marstand. The latest information on MARSTAND products can be found on our website: www.mahr.com, WebCode 210 marstand Indicator Stands, Comparator
More informationLevel and temperature switch Nivotemp NT-M, NT-MD
Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible
More informationPrecision Hand-held Thermometer
Precision Hand-held Thermometer measuring monitoring analysing Measuring range from -220 C... +1768 C Measuring accuracy starting with ±0.03% MV Large selection of temperature probes PT 100 or thermocouple
More informationTransparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling
Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover
More informationInductive Cylinder Position Sensors
Inductive Cylinder Position Sensors 4-Wire DC (NPN and PNP) 2-Wire AC/DC Weld immune 250, 000, and 3000 psi designs C-Series F-Series Rating (psi) Probe Diameter Inductive Cylinder Position Sensors Pepperl+Fuchs
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationJUMO Quantum PID100/PID200/PID300
Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and
More informationMULTI ROTARY SWITCH MR50
MAIN FEATURES 1 / 2 " SELECTOR SWITCH Dimensions Ø ½ (12.7 mm) Switching mode: Shorting or non-shorting Selector switch positions up to 16 Switching torque up to 6 Ncm Gold plated contacts Rugged design
More informationDuct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for
More informationPressure switch, Differential pressure switch RT
Data sheet switch, Differential switch RT An RT switch contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the set scale value. The RT series
More informationLevel and temperature switch Nivotemp NT-M, NT-MD
Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible
More informationFloat switch For industrial applications Model RLS-1000
Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic
More informationMULTI ROTARY SWITCH MR50
MAIN FEATURES 1 / 2 " SELECTOR SWITCH Dimensions Ø ½ (12.7 mm) Switching mode: Shorting or non-shorting 10, 12 and 16 selector switch positions Switching torque up to 6 Ncm Gold plated contacts Rugged
More information1.1 Functional Description: NO Switch Functional Description: Illumination TECHNICAL DATA AND DIMENSIONAL DRAWINGS...
Product Manual PSE NO Switch CONTENTS CONTENTS... 1 1 PRODUCT DESCRIPTION... 3 1.1 Functional Description: NO Switch... 3 1.2 Functional Description: Illumination... 4 2 TECHNICAL DATA AND DIMENSIONAL
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More informationPRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.
MESSKO MPreC PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS. MESSKO MPreC -Series LARGE MESSKO PRESSURE RELIEF DEVICE (LMPRD) Operating pressure Project/Reference: Gasket material MPreC Typ 4 psi; 0.28
More informationOptical Absolute Encoder Singleturn or Multiturn with hollow shaft Profibus-DP, CAN, CANopen, DeviceNet GX, G1, G2AMH / GX, G1, G2MMH
TM Optical Absolute Encoder Singleturn or Multiturn with hollow shaft,, open, GX, G1, G2AMH / GX, G1, G2MMH Features Interfaces:,, open, Resolution: 13 bit singleturn, 29 bit multiturn Parameterizable
More informationLS series. Electrical Position Indicators for Quarter Turn Actuators
0 Electrical Position ndicators for Quarter Turn Actuators Construction The GEMÜ electrical position indicators are used to indicate and monitor the position of quarter turn valves. Depending on the version,
More informationData is only for informational purpose. All specifications are subject to change without notice.
MV Data is only for informational purpose. All specifications are subject to change without notice. 1 First in knife gate 2018-12-19 solutions issue 24 Knife gate valve MV Stafsjö s knife gate valve MV
More informationElectrical Actuators
4 891 SSB without auxiliary switch SSB1 with auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB31 SSB81 SSB61 SSB31 operating voltage AC 230
More informationOutput signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V
Duct Air Quality Sensor Duct air quality sensor for detection of CO₂ with 0 to10 V output. Optional integrated, humidity, VOC sensors and LCD display. Type Overview Type active CO₂ 22DC-11 22DC-110L 22DCK-11
More informationNOVOHALL Rotary Sensor non-contacting. Series RSX-7900
NOVOHALL Rotary Sensor non-contacting Series RSX-7900 Special features very robust design to extreme environmental conditions high shaft load 300 N non-contacting, magnetic measuring angles up to 360 in
More informationPosition switches FD series
Position switches FD series Selection diagram 01 08 10 11 18 19 0 04 05 Ø 8 mm Ø 1,7 mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 31 51 5 57 35 56 41 4 adjustable
More informationPosition switches FD series
Position switches FD series Selection diagram 01 08 11 18 19 0 04 05 Ø 8 mm Ø 1, mm external rubber stainless steel stainless steel glass fibre rod gasket sphere sphere 51 5 5 5 56 41 4 adjustable lever
More information21023, 21025, 2/2 Direct solenoid actuated poppet valves
03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international
More informationElectrical Actuators
4 891 SSB without auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB1 with auxiliary switch SSB31 SSB61 SSB81 SSB31 operating voltage AC 230
More informationXLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance
XLF - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance Polycarbonate Fresnel lens Fixture without Fresnel lens Painted aluminium body E.2
More informationElectric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)
Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Application Electric actuators designed for valves used in heating, ventilation and air-conditioning systems as
More informationProduct data sheet accessories control and regulation Accessories AIRWIN
Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationRT2E Compact temperature switch Explosion proof
ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,
More informationElectromechanical pressure switches
Presentation Electromechanical pressure switches For control circuits, types ACW and ADW Presentation Pressure switches type ACW and ADW are switches for control circuits, with an adjustable differential.
More informationpneumatic push-in fittings system LF 3000
pneumatic push-in fittings system LF 3000 Parker Legris connectic products are available from MARYLAND METRIS P.O. Box 261 Owings Mills, MD 21117 USA ph: (410)358-3130 (800)638-1830 fx: (410)358-3142 (800)872-9329
More informationNon-Contact Safety System CES-AZ
Read head CES-A-LSP-... Optimized for aluminum profile mounting LED for the indication of the door position Read head CES-A-LSP-... M plug connector, 3-pin or hard-wire encapsulated cable 8,3 3,3 Mounting
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationAnalog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)
Page 1/10 JUMO AQUIS 500 ph Transmitter/Controller for ph, ORP, NH 3 (ammonia) concentration and temperature Brief description The instrument is used for measuring/controlling the ph, ORP or NH 3 (ammonia)
More informationPhotoelectrics Retro-reflective, Polarized Type PA18C.P..., DC
Photoelectrics Retro-reflective, Polarized Type PA18C.P..., DC Miniature sensor range Range: 5 m (axial), 4 m (radial) Sensitivity adjustment by potentiometer Modulated, red light 625 nm Supply voltage:
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...
More informationMicro calibration bath Models CTB , CTB
Calibration technology Micro calibration bath Models CTB9100-165, CTB9100-225 WIKA data sheet CT 46.30 for further approvals see page 3 Applications Calibration in the pharmaceutical industry and in the
More informationIP68 Sealed - Mini USB Buccaneer
IP68 Sealed - IP68 Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling Mini USB connector O ring maintains IP68 seal at connector interface Mini USB
More informationPI 500 Hand-held instrument for industry
PI 500 Hand-held instrument for industry The new PI 500 is an all-purpose hand-held measuring instrument for many applications in industry like e. g.: Flow measurement Pressure/vacuum measurement Temperature
More informationODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic
ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently
More informationother sizes available on request
ratiolab Cryo Boxes, Cardboard, Format 133 x 133 mm ratiolab Cryo Boxes, Cardboard, Format 133 x 133 mm Ultra low temperature-resistant cardboard. temperature-resistant down to 80 C available with a water-repellent
More informationenglish Cable Entry Systems EMC Solutions innovative creative technology Product program A company of the icotek group
english 26 Cable Entry Systems EMC Solutions innovative creative technology Product program A company of the icotek group Customer requests and our constant involvement in ever changing markets is motivation
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationPROXIMITY SENSORS. This document provided by Barr-Thorp Electric Co., Inc
PROXIMITY SENSORS www.turck.us Sensors Selection Guide Die Protector Whisker Probe Quick Mount Page L3 Page L4 Page L5 Cushion Mount Mounting Blocks Mounting Brackets Page L5 Page L6 Page L7 - L11 Mounting
More informationCompensating and connecting cables
sales@jumo.co.uk Data Sheet 90.9735 (90.9723) Page 1/8 Compensating and connecting cables compensating cables to EN 60584 and DIN 43714 versions from -190 to +400 C sheath in PTFE, silicone, PVC or fiberglass
More informationPreset counters, electromechanical
The electromechanical preset counters (with manual reset) boast a robust construction. They are ideal for use in harsh industrial environments as stand-alone counters or as plugin variants in combination
More informationYOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND
- YOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND MarStand Indicator Stands, Comparator Stands and Run out Testing Instruments offer high stablity which ensures precise measurements; regardless of whether
More informationData sheet: Wilo-Stratos 40/1-8
Data sheet: Wilo-Stratos 4/1-8 Pump curves 1 2 v 3 4 DN4 m/s,5 1, 1,5 2, 2,5 DN5 H/m Wilo-Stratos 4/1-8 p/kpa Wilo-Stratos 5/1-8 48 1 /min - 1 V 1~23 V - DN 4 / DN 5 8 8 P 1/W n= const 6 383 1 /min - 8
More informationACCESSORIES. Accessories for distance and position sensors Magnets for HLT 1000, HLT 2000, HNT Electrical accessories HLT
Accessories ACCESSORIES Accessories to suit every sensor! Whether it's electrical connectors, mechanical adapters or the instrument mounting clamps, the wide range of products from HYDAC offers solutions
More informationCITY OF FREMONT SPECIFICATIONS 2017 WATER & SEWER MAINTENANCE SUPPLIES
CITY OF FREMONT SPECIFICATIONS 2017 WATER & SEWER MAINTENANCE SUPPLIES All bidders MUST submit product specifications, literature describing items, manufacturers name, product code and part numbers with
More informationInstallation Instructions and techn. Documentation
Installation Instructions and techn. Documentation Tank-Spion Digital LX-2 / LX-2-R / LX-Q LX-2 Tank monitoring device with level meas. probe. LX-2-R With additional relay control functions. LX-Q With
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft
echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage
More informationPipe fittings and flanges, sockets for bayonet locks
Data Sheet 909750 (909725) Page 1/7 Pipe fittings and flanges, sockets for bayonet locks for temperatures up to 600 C for different fitting lengths simple installation and replacement pressure-tight sealing
More informationCompact universal controllers
7 867 Compact universal controllers RWF55... The RWF55 is used mainly for controlling the temperature or pressure in oil- or gas-fired heating plants. If the relevant parameters are set, the RWF55 can
More informationPile Driver Weld Immune Sensors
DC... 190 8, 12, 18, and 30 mm Diameter... 190 3- and 4-Wire DC... 192 8, 12, 18, and 30 mm Diameter... 192 AC/DC... 194 12, 18, and 30 mm Diameter... 194 Pile Driver Sensors P+F s weld immune Pile Driver
More informationHERZ Actuator 7708, 7990
HERZ Actuator 7708, 7990 Data sheet for 7708, 7990 Issue 1116 Dimensions Dimensions Installation height Dimensions Installation height Dimensions Installation height Page 1 Models HERZ Actuator 2-point,
More informationCapacitance level switches LS 210 LS 220
KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,
More information