1 SMS relay INTERFACE Data sheet _en_03 PHOENIX CONTACT Description The PSI-MODEM-SMS-REL... is a compact remote control and signaling system. Six digital or configurable analog/digital inputs and four relay outputs with PDT contacts are monitored and controlled using SMS messages via any GSM mobile phone network. The integrated phonebook stores up to 50 numbers and addresses that are to receive the messages. Each change of status at the input sends a user-defined message to the selected receivers via SMS or . A predefined message can be used to enable and disable the outputs via SMS. In this way, an error can be acknowledged and even removed remotely. To obtain an overview of the system state, the status of the inputs and outputs can be queried. As an option, the relay outputs can be switched for a predefined period and then return to their initial state. Integrated password protection prevents unauthorized access. The PSI-MODEM-SMS-REL... is set up using the supplied configuration software. Possible fields of application of the PSI-MODEM-SMS-REL... are: Machine, building, and system monitoring Pumps, sewage treatment plants, water supply Lighting control systems, remote switchgears Elevators, gates Alarm and home technology HVAC technology 1.1 Properties SMS status query of all inputs and outputs SMS remote control of outputs Notification via SMS on change of status at input Maximum of 5 receivers per SMS message Alarm generation on voltage failure via SMS Easy configuration on PC without programming knowledge Installation component model according to DIN Mobile phone network: 850 MHz, 900 MHz, 1800 MHz, 1900 MHz (quad band GSM module) WARNING: This device is not suitable for monitoring sensitive systems or time-critical processes. GSM network failures or interruptions to the power supply may adversely affect monitoring. Make sure you always use the latest documentation. It can be downloaded at This data sheet is valid for all products listed on the following page:

2 2 Ordering data SMS relay Description Type Order No. Pcs./Pkt. SMS relay with six digital inputs and four relay outputs SMS relay with six configurable analog/digital inputs and four relay outputs PSI-MODEM-SMS-REL/6 DI/4DO/ AC PSI-MODEM-SMS-REL/6ADI/4DO/ DC Accessories Description Type Order No. Pcs./Pkt. GSM-UMTS antenna with omnidirectional characteristics, antenna cable with SMA round connector Degree of protection Dimensions 2 m IP65 76 mm x 20 mm GSM-UMTS omnidirectional antenna, 2 dbi boost, 5 m antenna cable with SMA round connecto GSM/UMTS antenna cable, 10 m long; SMA (male) -> SMA (female), 50 Ohm impedance GSM/UMTS antenna cable, 5 m long; SMA (male) -> SMA (female), 50 Ohm impendance Connecting cable, 9-pos. D-SUB to USB, with 9-pos. D-SUB to 25-pos. D-SUB adapter PSI-GSM/UMTS-QB-ANT PSI-GSM/UMTS-ANT-OMNI PSI-CAB-GSM/UMTS-10M PSI-CAB-GSM/UMTS-5M CM-KBL-RS232/USB Technical data General data Housing Housing dimensions (W x H x D) DIN housing system 88 mm x 90 mm x 60 mm Fixing 35 mm DIN rail according to DIN EN Connection Degree of protection Housing material Weight Ambient conditions Screw terminal block 2.5 mm 2, 0.5 Nm, Pozidrive/slotted head IP20 Noryl SE1, Lexan EXL g, approximately Ambient temperature (storage) -40 C +85 C Ambient temperature (operation) -25 C +55 C Relative humidity 0%... 95% (no condensation) Transient protection Single pulse 2.5 kv/2.5 Ws Electrical data.../6 DI/4DO/AC.../6ADI/4DO/DC Nominal operating voltage 110 V AC V AC 12 V DC V DC Operating voltage 85 V AC V AC 10 V DC V DC Frequency range 45 Hz 63 Hz Standby current consumption Conditions: Dialed into the GSM network, no communication active, inputs not 10 ma, approximately at 230 V AC 15 ma, approximately at 24 V DC 25 ma, approximately at 12 V DC controlled, relay disabled Nominal current consumption 10 ma 15 ma Inrush current surge < 2.6 A, τ = 0.4 ms 2.6 A, τ = 0.4 ms Digital inputs IN /6 DI/4DO/AC.../6ADI/4DO/DC Control voltage range 110 V AC V AC 12 V DC V DC Input voltage range 0 V AC V AC 0 V DC V DC Operate threshold 85 V AC 9.5 V DC Hysteresis 20 V, approximately 5 V, approximately _en_03 PHOENIX CONTACT 2

3 Digital inputs IN /6 DI/4DO/AC.../6ADI/4DO/DC Current consumption 4 ma/230 V 1.5 ma/24 V Permissible residual current 0.9 ma 20 µa Cable capacitance 50 nf Inductive parallel load energy 50 mws/1 Hz (2.5 kv) 50 mws/1 Hz (2.5 kv) Analog inputs IN /6ADI/4DO/DC Nominal input range V DC Effective input range V DC Maximum input voltage 60 V DC Resolution 10 bits, LSB 12.5 mv, approximately Input impedance 142 kω Error limit, with reference to input range ±1% Time data Supply startup time (Ri = 0) Minimum control duration for input (AC, DC) Mains reliability 25 s 200 ms 15 ms Relay outputs OUT /6 DI/4DO/AC.../6ADI/4DO/DC Contact type Single contact, 4PDT Single contact, 4PDT Limiting continuous current 10 A (total current 20 A, maximum) 10 A (total current 20 A, maximum) Inrush current 15 A/20 ms 15 A/20 ms Maximum switching voltage 250 V AC 250 V AC Maximum switching power 2500 VA 250 W Minimum switching voltage 12 V 12 V Minimum switching current 10 ma 10 ma Contact material AgNi 90/10 AgNi 90/10 Mechanical service life 30 x 10 6 cycles 30 x 10 6 cycles Test voltage Device - contact Contact - contact 2.5 kv (50 Hz, 1 min.) 2.5 kv (50 Hz, 1 min.) 2.5 kv (50 Hz, 1 min.) 2.5 kv (50 Hz, 1 min.) Wireless interface Antenna Frequency 50 Ω impedance SMA female antenna connector, GSM interface 850 MHz at 2 W (EGSM) 900 MHz at 2 W (EGSM) 1800 MHz at 1 W (EGSM) 1900 MHz at 1 W (EGSM) Standards Safety EN :2000 EMC, immunity to interference EN :2005 EMC, noise emission EN :2007 Approvals, conformance, marking c, UL Conformance with R&TTE directive 1999/5/EC Yes _en_03 PHOENIX CONTACT 3

4 3.1 Characteristic curves DC interrupting rating 4 Dimensions Switching voltage [V DC] Ohmic load Ø Figure 3 Dimensions in mm 5 Safety notes Figure 1 Electrical service life Cycles Switching current [A] DC interrupting rating 250 V AC Ohmic load WARNING: Danger Never carry out work when voltage is present. WARNING: This device is not suitable for monitoring sensitive systems or time-critical processes. GSM network failures or interruptions to the power supply may adversely affect monitoring. WARNING: Only qualified personnel may connect the power, start up, and operate this device. According to the safety instructions in this text, qualified personnel are persons who are authorized to start up, to ground, and to mark devices, systems, and equipment according to the standards of safety technology. In addition, these persons must be familiar with all warning instructions and maintenance measures in this text. Disregarding this warning may result in damage to equipment and/or serious personal injury. Figure 2 Electrical service life Switching current [A] WARNING: When connecting to the 230 V AC mains, ensure that the supply and the supply of the inputs come from the same pole conductor. No voltage of over 240 V AC should occur at the device itself _en_03 PHOENIX CONTACT 4

5 6 Overview of functions 6.1 Operation The module starts operating automatically when the voltage is applied. If the GSM signal level is sufficient, the module logs in to the GSM network. Two LEDs indicate the status. The GSM LED indicates whether or not the module is logged into the GSM network. In addition, the transmission of an SMS message is visualized. The status LED indicates the operating states of the SMS relay. 6.2 Messages The application of a signal or a signal change at an input triggers an SMS message or . An SMS message can be sent to several receivers simultaneously or in succession. The configuration to send messages "in succession" means that if the SMS message is not acknowledged by a receiver, it is automatically forwarded to the next device after a preconfigured time. Alarm generation chains with a maximum of five receivers per I/O can therefore be defined. When the module is switched on, an SMS message is sent to all configured numbers. This means that a voltage interrupt or voltage recovery can be indicated. Power failure In the event of a voltage failure, up to 5 messages can be sent if required. Following voltage recovery, a message can be sent to predetermined devices if required. Remote control The outputs can be controlled (ON/OFF) using a defined SMS message (default message is "#PASSWORD:SET:OUTPUT1"). If caller identification is activated, SMS messages are only accepted from numbers that are in the phonebook of the SMS relay. 6.3 Remote querying The status of inputs and outputs can be queried via SMS. Again, the SMS message can be individually configured. 6.5 Configuration software The supplied SMS-REL-CONF configuration software supports the user during startup and on later modifications to the settings. The software runs on a standard PC with Windows 2000 or later to Windows 7. The SMS relay is connected to the PC via a serial V.24 (RS-232) connecting cable. The following settings can be made: Entering a PIN for the SIM card (optional) Changing the PIN for the SIM card Message when the module is switched on/off Message as a function check at a fixed interval in minutes, hours or days Receiver addresses for the SMS, controlled by the inputs Required confirmation when SMS is received can be enabled/disabled Number identification (caller ID) on/off Text for the relevant input can be freely defined (2x) Text for control of the relevant output can be freely defined (3x) SMS message on a change in signal status (rising and/ or falling edge) at the input Enabling and/or disabling the output, constant or for a set duration Acknowledgment of every control command (configurable) Password required for remote control (on/off) In addition to the settings, various queries can be made (diagnostics): GSM reception (field strength) Network provider display and selection (in home network defined by SIM card) Credit balance query (for prepaid cards, function is not supported by all mobile phone providers) Status query for GSM and module (according to LED) 6.4 Configuration The SMS relay is configured via a PC, which is connected to the SMS relay via a serial V.24 (RS-232) interface _en_03 PHOENIX CONTACT 5

6 7 Connecting the SMS relay 7.1 Selecting an antenna The SMS relay is supplied with a rod antenna. Prior to installation, the installation location must be taken into account during antenna selection. NOTE: The device antenna is not suitable for use in a control cabinet (shielding). The PSI-GSM/UMTS-QB-ANT external GSM omnidirectional antenna (see "Ordering data" on page 2) for mounting on the control cabinet provides better receive quality. Before mounting the antenna, check the signal quality from your provider. Screw on the supplied device antenna or connect another suitable antenna. 7.3 Wiring the SMS relay WARNING: During electrical installation, observe the usual standards and regulations. Installation must be carried out by an expert. WARNING: When connecting to the 230 V AC mains, ensure that the supply and the supply of the inputs come from the same phase. No voltage of over 240 V AC should occur at the device itself. Connect the SMS relay as shown in the connection diagram below: PSI-MODEM-SMS-REL/6 DI/4DO/AC 7.2 Mounting WARNING: Only mount and remove the SMS relay when the power supply is disconnected. Mount the SMS relay on a 35 mm EN DIN rail (see Figure 4). Figure 5.../6 DI/4DO/AC PSI-MODEM-SMS-REL/6ADI/4DO/DC Figure 4 Mounting NOTE: The SMS relay must only be connected to devices, which meet the requirements of EN ("Safety of Information Technology Devices"). Figure 6.../6ADI/4DO/DC _en_03 PHOENIX CONTACT 6

7 Connecting the outputs NOTE: Always connect the voltage source to the center contact (11, 21, 31, 41) of the PDT and the load to the N/C contact (12, 22, 32, 42) or N/O contact (14, 24, 34, 44). 7.5 SIM card NOTE: Disconnect the device power supply before replacing the SIM card. The device only supports 3 V SIM cards. For older SIM cards, please contact your GSM service provider. Opening the housing Open the housing cover to access the SIM card holder inside. Figure 7 Connecting the outputs (using the example of the.../6 DI/4DO/AC) 7.4 Connecting the SMS relay and PC The SMS relay and the PC are connected together using the supplied connecting cable. The cable is a connecting cable with 1:1 connected contacts. Open the housing cover to access the programming interface inside. Connect the V.24 (RS-232) interface of your PC to the programming interface of the SMS relay using the supplied connecting cable. If no V.24 (RS-232) slot is available on the PC, use a USB adapter (e.g., CM-KBL-RS232/USB, see "Ordering data" on page 2). DCD TxD RxD RTS CTS DTR DSR RI GND PC D-SUB 25 9 max. 15 m D-SUB SMS relay DCD TxD RxD RTS CTS DTR DSR RI GND Inserting the SIM card Your GSM service provider will have supplied you with a SIM card where all the important data for your connection is stored. If you have been supplied with a SIM card in credit card format, simply detach the small section of the card and remove any excess plastic from the edges. Slide the SIM card into the holder with the contact surface facing down. Note the position of the diagonal corner. PIN code The SIM card can be protected with a 4-digit PIN code. The PIN code is entered using the SMS-REL-CONF configuration software (see "PIN" on page 11). 7.6 TEST and RESET button There are two buttons under the cover: RESET on the left and TEST on the right: Pressing the TEST button for 5 seconds sends a test SMS with the contents "Test". Pressing the RESET button for at least 15 seconds sets all outputs to the zero current and open position. Figure 8 V.24 (RS-232) interface a _en_03 PHOENIX CONTACT 7

8 8 Installing the software 8.1 System requirements The SMS-REL-CONF configuration software runs on all the latest Microsoft operating systems. To ensure that the software works properly, the following system requirements must be met: Operating systems: Windows 2000, Windows XP, Windows Vista, Windows 7 CPU computing capacity: Pentium 166 MHz, recommended: Pentium III/800 MHz RAM: 256 MB Available memory on the hard disk: 40 MB Programming interface: V.24 (RS-232) USB (with USB to V.24 (RS-232) interface converter) Minimum screen resolution of 1024 x 768 pixels NOTE: If the screen resolution is too low, the configuration software window is not fully displayed, i.e., the registers for programming may not be visible. 8.2 Installing the configuration software Proceed as follows: Insert the supplied CD-ROM. The installation menu starts automatically. If it does not open automatically, double-click on the "SMS-REL-Conf...setup.exe" file on the CD-ROM. Select a language. During installation, please follow the instructions in the setup program. 9 Operating the SMS relay 9.1 Starting up the SMS relay Proceed as follows: Disconnect the SMS relay from the network. Insert the SIM card (see page 7). Connect the PC and SMS relay using the supplied connecting cable (see page 7). Connect the SMS relay to the network. As soon as the SMS relay is ready (after around 100 seconds), the status and GSM LEDs flash regularly every second. Start the configuration software. Open the corresponding configuration file or create a new file. Select the relevant COM port. ("Configuration" menu, "Select Port"). Download the file to the SMS relay ( Download). Wait until the SMS relay is ready (after around 100 seconds). Set the time in the SMS relay. Each message is assigned a time stamp, so messages cannot be sent unless the time is set. Set the time for the SMS relay ("Configuration" menu, "Set Time"). 9.2 Status indicators (LEDs) The SMS relay has two LEDs (the GSM LED and the status LED). Both LEDs are located under the cover but are visible from the outside. The following states are indicated by these LEDs: GSM LED State Flashing regularly (every second) Short flashes (around every three seconds) Flashing irregularly Meaning Module is not logged into the GSM network Module is registered and ready for data communication Transmitting data (SMS) _en_03 PHOENIX CONTACT 8

9 Status LED State LED OFF Flashing sporadically (irregular) 1 x short flashes (around every three seconds) 2 x short flashes (around every three seconds) 3 x short flashes (around every three seconds) 1 x flashing regularly (every second) 2 x flashing regularly (every second) 3 x flashing regularly (every second) Status of the inputs and outputs Meaning Device not running Device starting up Device running, everything OK No more credit Time not set Module in initial status Configuration error Communication error The states of the inputs and outputs are indicated by the status LED: Inputs IN 1, IN 2, IN 3, IN 4, IN 5, IN 6 (LED ON = Input enabled) Outputs OUT 1, OUT 2, OUT 3, OUT 4 (LED ON = Output enabled) Error codes and their meaning: Error Meaning Cause Measure code 1 No credit Prepaid card Top up card empty 2 Time not set Time not set "Configuration" menu, "Set Time" 3 No relay.csr No configuration Load file found loaded 4 Configuration error 5 Communication error File not fully downloaded SMS was not sent because of the bad GSM signal or the SMS relay is not registered Card blocked PIN entered incorrectly 3 times 1002 No SIM card SIM card is missing or dirty Load file again Check antenna and SIM card SIM card must be inserted in a mobile phone and unlocked (unlock PUK) Insert SIM card 9.3 Behavior in the event of power failure Brief power failures (t < 1 second) are buffered and do not change the status at the module. Longer power failures (t 1 second) are detected and an alarm SMS message is sent according to the configuration. The device then switches off. In the event of a voltage failure, once the device has restarted and the SMS relay has logged into the GSM network, the states of the outputs are the same as before the failure (memory function). 9.4 Diagnostics and error messages The SMS relay, together with the configuration software, can display the current receive quality (field strength). The SMS relay must be connected to a PC via the connecting cable. Diagnostics can be accessed via the "Option" menu, "Diagnostics". In addition to the receive quality, other device information is also provided (version numbers, error codes, and network provider) _en_03 PHOENIX CONTACT 9

10 10 Configuring the SMS relay 10.1 Configuration in online and offline mode The SMS relay configuration can be set up (e.g., create phonebook, enter SMS messages) without a connection to the device. A new or existing file can be opened and edited for this purpose. The created file must then be downloaded to the SMS relay via the connecting cable. In offline mode, diagnostics are not active. The diagnostics can only be accessed once the SMS relay is connected to the PC. Establishing a connection Disconnect the SMS relay from the network. Insert the SIM card (see page 7). Connect the PC and SMS relay using the supplied connecting cable (see page 7). Connect the SMS relay to the network. As soon as the SMS relay is ready (after around 100 seconds), the status and GSM LEDs flash regularly every second. Start the configuration software. Open the corresponding configuration file or create a new file. Select the relevant COM port. ("Option" menu, "Communication Settings"). The SMS relay can now be configured to meet your requirements or the prepared file can be downloaded Selecting the language The SMS relay configuration software offers the option of changing language. The program does not have to be restarted after the selection has been made. In the "Option" menu, select "Select language" and then select the desired language Managing the phonebook The software offers the option of managing up to 50 phone numbers or addresses. Phone numbers The numbers are the receivers of SMS messages. With a defined security option, only the devices entered in the phonebook can switch the outputs of the SMS relay. Figure 9 SMS relay phonebook Enter the phone numbers in international format (with country code and dialing prefix), e.g., (+41 Switzerland, +49 Germany, +31 The Netherlands) The "Name" array can be used to sort the list alphabetically in ascending or descending order. Sorting has no effect on entries that are used. The "default" entry shall be replaced with an own entry! Add Enter a new phone number Edit Edit a selected phone number Delete Delete a selected phone number addresses Activate first the function in the field "Activate " and enter the provider service number. Register now the addresses as follows: Add register of a new address Edit editing of an already existing entry Delete deleting of an existing entry Please enter the addresses in the format xxx@xxx.xx _en_03 PHOENIX CONTACT 10

11 10.4 Specifying basic settings You can now configure the SMS relay. Figure 10 SMS relay settings The "Settings" tab is used to set data for sending SMS messages, which is used for device identification. PIN The SIM card is protected with a PIN code. Enter the SIM card PIN code in the "Enter PIN (Device)" field. A configuration file can only be transmitted to the SMS relay if a PIN is entered. However, in offline mode a configuration file can be edited and saved without entering a PIN. For other data, please refer to the SIM card documentation. This also describes how the SIM card can be unlocked if it is blocked after three incorrect PIN entries. To do this, the SIM card is removed from the SMS relay and inserted in a mobile phone. The card can now be unlocked according to the network operator's instructions. Provider search The automatic provider search depends on the SIM card inserted in the SMS relay. The provider data and access rights stored on the SIM card are used. The operator is always specified when the SIM card is purchased. With the "Automatic" option, the network operator is selected according to the SIM card. This is useful when the card is operated in a home network. When used overseas, the same SIM card can be operated on other GSM networks depending on the roaming contract. With the "Manual" option, the system scans several times for available GSM networks. The result of this search is displayed in a network list. Click "Search" to display the available networks. The desired network can now be selected. SMS relay description The "SMS Relay description" field can be used to enter the installation location of the SMS relay. All messages sent by this SMS relay use this name for identification. The SMS relay identification can be deactivated so that the messages can be sent without this identification. The character length of the entire SMS message is reduced by the character length of this name. The number of characters currently available is displayed. NOTE: The use of special characters may cause problems. Please use only letters and numbers. Trailing information The trailing information of each message (date, time, remaining balance) can be activated or deactivated in the field "Trailing Message Info" located under tab "Settings". Enable local authentication The local access via RS-232 can be protected by a password. Receivers of status messages The receivers of SMS messages can be selected from the phonebook. To do this, click on the expansion arrow and select the corresponding entry _en_03 PHOENIX CONTACT 11

12 10.5 Setting status messages "Startup message" This option can be used to send a corresponding SMS message to the preset numbers on every SMS relay startup (power up or voltage recovery). The contents of the SMS message can be modified and adapted to meet your requirements. "Power failure message" This option can be used to send a corresponding SMS message to the preset numbers on every SMS relay voltage failure, informing the receiver that the supply voltage has failed in the application. The contents of the SMS message can be modified and adapted to meet your requirements. Figure 11 SMS relay settings The SMS relay can send the following status messages. NOTE: The use of special characters may cause problems. Please use only letters and numbers. Remote querying all inputs and outputs The device offers the option of querying the status of all inputs and outputs via SMS. To do this, a password is sent to the device via SMS. The preset password is "#PASSWORD:SEND:STATUS". It can be fully adapted and modified to meet your requirements for remote querying. The response is sent to the same phone number (caller ID). The states of the inputs and outputs are indicated in the SMS message as follows: I: Inputs 1 to 6 (0 = OFF/1 = ON) O:0101 Outputs 1 to 4 (0 = OFF/1 = ON) "Send the status of all In- and Outputs with every message" This option can be used to send the status of inputs and outputs in the above format with every SMS message. "Send periodic status message" The periodic message is used as a function check. An SMS message is sent at regular intervals. The message can be sent daily (time), weekly (time, day) or monthly (time, date). The contents of the SMS message can be modified and adapted to meet your requirements _en_03 PHOENIX CONTACT 12

13 PSM MODEM SMS RELAY Input Output PSI-MODEM-SMS-REL/AS/6DI/4DO Output Ord.No.: V / 10A GSM Status PSI-MODEM-SMS-REL Configuring inputs Figure 12 Configuring inputs Figure 13 Settings for input 1 General SMS IN The SMS relay has 6 inputs. Each of these inputs can send a freely definable SMS message to up to five predefined phone numbers when controlled or if the input signal fails. In general, two events can trigger an SMS: the change from "ON" to "OFF" and the change from "OFF" to "ON". Both events can be activated, or just one event can be activated. A separate message text can be entered for each event. NOTE: The use of special characters may cause problems. Please use only letters and numbers. If the "Confirmation" option is selected, the event message is sent to the next receiver if the SMS relay does not receive confirmation from the receiver within a specified period of time. Alarm generation chains with a maximum of five receivers can therefore be defined. The device processes the five assigned receiver numbers and then begins again at the first number. This process is repeated for the number of cycles specified under "Number of loops". As soon as the device receives a confirmation, the process is stopped. If no confirmation is received, the message is sent to the next receiver once the specified time has elapsed. If the "Keyword for confirmation" option is not selected, caller ID is used as the security check and a blank SMS can be sent to the SMS relay as confirmation. If the "Confirmation" option is not selected, all the receivers assigned to this action receive an SMS message at the same time, with no repetition. If a password is specified for confirmation, an SMS must be sent to the SMS relay with this password in order to stop the alarm generation chain. Sometimes several inputs may change state simultaneously or at least within the same message process. These changes in state are detected simultaneously by the SMS relay and one SMS is sent for each change in state. Switch-on delay If an input signal is present, it is possible to set a time delay for sending the message. When switch-on delay is active, the SMS relay only responds after the set time by sending the predefined message if the signal is still present. In other words, the input signal is ignored for this period of time. Time delays from 0.1 seconds to 99.9 hours can be set. Off delay If an input changes from HIGH to LOW, i.e., the signal is no longer present at the input, an off delay can be activated. When off delay is active, the SMS relay only sends the predefined message after the set time if the signal has not been restored. Time delays from 0.1 seconds to 99.9 hours can be set. NOTE: Ensure that each input has at least one phone number in the list of receivers. This applies even if the input is not connected. If there is no receiver entered for an input, the file cannot be saved or downloaded to the SMS relay _en_03 PHOENIX CONTACT 13

14 PSM MODEM SMS RELAY Input Output PSI-MODEM-SMS-REL/AS/6DI/4DO Output Ord.No.: V / 10A GSM Status PSI-MODEM-SMS-REL Configuring outputs SMS OUT Figure 14 Configuring outputs The device only responds to the precise wording, i.e., the message must correspond exactly to the set wording. The device is not case-sensitive. NOTE: The use of special characters may cause problems. Please use only letters and numbers. If the "Number identification" option is selected, switching commands are only taken into account if they come from numbers entered in the phonebook. The SMS relay can send a confirmation to the sender when an output is switched. The contents of the SMS message can be modified and adapted to meet your requirements. SMS texts for switching on and switching off can be detected. In addition, an SMS message can be defined that is sent if an output is already in the desired state and therefore no action was taken. These SMS messages are always sent to the sender of the message. Time function A time function can be used to switch off an output after a certain period of time without a switching command being sent via SMS. Switching times from 0.1 seconds to 99.9 hours can be set. If the output switches off after the set time has elapsed, an SMS message is sent which confirms this action. If a switching command is sent before the set time has elapsed, this command is followed. This time function must be activated separately. Figure 15 Settings for output 1 The SMS relay has 4 relay outputs (PDT, 10 A, 250 V). These outputs can be controlled via SMS, i.e., they can be switched ON or OFF. Each output can be activated separately. The password and message text for switching the output can be freely defined. The text is preset to "#PASSWORD:SET:OUTPUT1" and can be adapted to meet your requirements. Due to the existing tolerances, the switching times do not support the monitoring or control of time-critical processes _en_03 PHOENIX CONTACT GmbH & Co. KG Blomberg Germany Phone: PHOENIX CONTACT P.O.Box 4100 Harrisburg PA USA Phone:

PSI-GPRS/GSM-MODEM/RS232- QB

PSI-GPRS/GSM-MODEM/RS232- QB PSI-GPRS/GSM-MODEM/RS232- QB Serial mobile communication modem for GSM and GPRS Data sheet 103144_en_03 PHOENIX CONTACT 2015-05-12 1 Description The DIN-rail-mountable PSI-GPRS/GSM-MODEM/RS232- QB mobile

More information

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description (-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase

More information

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description. Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

PSI-GPRS/GSM-MODEM/RS232-QB

PSI-GPRS/GSM-MODEM/RS232-QB Extract from the online catalog PSI-GPRS/GSM-MODEM/RS232-QB Order No.: 2313106 Industrial GPRS/GSM modem for assembly on EN DIN rail. GSM and GPRS. 850 + 900 + 1800 + 1900 MHz. Serial RS-232 interface.

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

PSR UC/ESAM4/3X1/1X2/B

PSR UC/ESAM4/3X1/1X2/B Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC

More information

CONTA-ELECTRONICS GSM-PRO

CONTA-ELECTRONICS GSM-PRO CONTA-ELECTRONICS GSM-PRO Portal Software The GSM-PRO, like most SMS modules, are often used as stand-lone units used in the field. The new GSM-PRO portal software from CONTA-CLIP in the field. These modules

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5 Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of

More information

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface

More information

PHOENIX CONTACT - 04/2008

PHOENIX CONTACT - 04/2008 Serial Bluetooth adapter for a wireless connection of a serial interface to a Bluetooth access point AUTOMATION Data Sheet 7660_en_01 PHOENIX CONTACT - 04/2008 1 Description The FL BLUETOOTH Serial Port

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

QUINT-PS-3x AC/24DC/10

QUINT-PS-3x AC/24DC/10 3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL

More information

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C 1 Description PHOENIX CONTACT 2011-06-07 2 Features The RAD-WHG/WLAN-XD is a WirelessHART gateway with integrated 802.11b/g

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B

More information

PSR DC/ESP4/2X1/1X2

PSR DC/ESP4/2X1/1X2 PSR-...- 24DC/ESP4/2X1/1X2 Safety relay for emergency stop and safety door monitoring Data sheet 100516_en_05 PHOENIX CONTACT 2013-11-21 1 Description The safety relay can be used for emergency stop and

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

Product description Rev. 3 11/06/14

Product description Rev. 3 11/06/14 EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and

More information

ModemUSB/E12 User Manual v0.1

ModemUSB/E12 User Manual v0.1 User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS...2 1. ATTENTION...3 2. FOR YOUR SAFETY...3 3. USER S SERVICE...5 4. BASIC INFORMATION...6 4.1 Introduction...6 4.2 Legal Notice...6 4.3 Contacts...6

More information

Valueline Industrial PC

Valueline Industrial PC A configurable industrial computer platform AUTOMATION Data Sheet 2643_en_F 1 Description PHOENIX CONTACT 2011-07-15 2 Features The Valueline Industrial PC (VL IPC) product line is a configurable industrial

More information

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Data Sheet Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks.

More information

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs INTERFACE Data sheet 104832_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DAIO6-IFS I/O extension module can be

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

GT- IRDM-9603 Product description Rev. 2 17/06/2014

GT- IRDM-9603 Product description Rev. 2 17/06/2014 GT- IRDM-9603 Product description Rev. 2 17/06/2014 1 1. Overview The GT- IRDM- 9603 is a complete Satellite Terminal solution for Satellite applications. Based on IRIDIUM 9603 module. 2. Hardware Interface

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010.

Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010. Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010. Document name: User's Manual Device: GSM Key Revisions history: Version Date Comment Corresponding device firmware 1.0 10.11.2010.

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SAFETY RELAY YRB-4EML-31S MAIN FEATURES SAFETY RELAY TYPE 4 SAFETY PROTECTION DEVICE FOR SAFETY LIGHT CURTAINS/BARRIERS MAIN FEATURES For safety light curtains and access control barriers, emergency stop, door switch Safety Integrity Level (SIL)

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

UP100-GSM. GSM based intercom and access control. Installation and user manual

UP100-GSM. GSM based intercom and access control. Installation and user manual UP100-GSM GSM based intercom and access control Installation and user manual UP100-GSM REV.1.4 20/01/2014 Table of contents 1 Functions...3 2 Features...3 3 Application area...3 4 Operation...3 4.1 Visitor

More information

Operation Manual GSM modem irz TG42-232

Operation Manual GSM modem irz TG42-232 Operation Manual GSM modem irz TG42-232 Table of Contents 1. Introduction... 4 1.1. About this Document... 4 1.2. Service Information... 4 1.3. Safety Precautions... 4 2. Overview... 5 2.1. Purpose...

More information

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS SWH Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS Rev.1 01/03/2013 1. Overview The SWH is a complete board Cellular Terminal solution for GSM GPS/GLONASS applications.

More information

Installation and Configuration Quick Guide GoRugged M1000 MP

Installation and Configuration Quick Guide GoRugged M1000 MP Installation and Configuration Quick Guide GoRugged M1000 MP Industrial Cellular Modem 1 RS-232/RS-485 + 1 USB Host Package Contents Before installing your M1000 MP Modem, verify the kit contents as following.

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

TELTONIKA ModemUSB/G10 User Manual v0.1

TELTONIKA ModemUSB/G10 User Manual v0.1 Address: Žirmūnų g. 27, Vilnius LT-09105, Tel.: +370 5 2127472, Fax: +3705 276 1380, E-mail: info@teltonika.lt TELTONIKA User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 1. ATTENTION... 3 2. FOR

More information

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0 monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine Version: 01.01 AQ_G24 Terminal Card_HD_V01.01 17.JUL.2008-1 - Hardware Interface Description 1. Hardware Features of the AQ_G24 Terminal Card Feature

More information

GNS-MC35iT, GNS-MC35iU Terminals datasheet

GNS-MC35iT, GNS-MC35iU Terminals datasheet datasheet 2007 Contents Document history...3 1 Abstracts...4 2 Key features...4 3 Electrical and environmental characteristics...5 4 Operating modes...7 5 Power supply...8 6 Power on/off control...9 7

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and

More information

PHOENIX CONTACT - 10/2009

PHOENIX CONTACT - 10/2009 Factory Line Switches With Standard Functions AUTOMATIONWORX Data Sheet PHOENIX CONTACT - 10/2009 Description The range of Factory Line switches with standard functions in numerous versions can be used

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

GD-02-DIN Universal GSM communicator and controller

GD-02-DIN Universal GSM communicator and controller The GD-02-DIN Universal GSM communicator and controller remotely controls and monitors the status of various appliances. Controlling can be performed using standard SMSes or by dialling in. The device

More information

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual Industrial Quad-band GPRS/GSM Modem GTM-201 Series User Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches

More information

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is

More information

Hardware Interface Description

Hardware Interface Description Cellular GSM Engine Hardware Interface Description Feature Incorporates 700XR/A module Frequency bands Power supply Operating temperature Physical RoHS, WEEE Implementation The module handles all processing

More information

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PSR-PS21. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual Converter USB RS 232/422/485/485-4W/TTL Manual _v1_01 Update date: 10/2018r. 10/2018 _v1_01 1 Table of Contents Symbols & Marks...3 General installation and safety rules...3 1.Destination of device...4

More information

RTS ISDN 2002 System. Operator Manual Software Description

RTS ISDN 2002 System. Operator Manual Software Description RTS ISDN 2002 System Operator Manual Software Description PAGE 1-2 RTS ISDN 2002 System A Publication of EVI Audio GmbH Hirschberger Ring 45 D-94315 Straubing Telephone + 49 9421 706-0 Fax + 49 9421 706-422

More information

A2000 Multifunctional Power Meter

A2000 Multifunctional Power Meter 3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power

More information

TM221M16R controller M IO relay

TM221M16R controller M IO relay Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

STD Simple Telemetry Application. Owner s Manual

STD Simple Telemetry Application. Owner s Manual STD47 1.0 Simple Telemetry Application Owner s Manual Table of Content 1. Safety Information... 4 2. Main Functions:... 5 2.1. Start-Up alarm message... 5 2.2. Digital Output control:... 5 2.3. Digital

More information

Model 3750 Multifunction I/O Card

Model 3750 Multifunction I/O Card Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Model 3750 Multifunction I/O Card Connection Instructions and Specifications Introduction This instruction

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX 1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas -PS-100-240AC/24/5/EX POWER provides: Preventive function monitoring through professional signaling Global use due to a

More information

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. UC-8100 Series Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports Features and Benefits Armv7 Cortex-A8 300/600/1000 processor Dual auto-sensing 10/100 Mbps Ethernet

More information

IB IL 24/48 DOR 2/W-XC-PAC

IB IL 24/48 DOR 2/W-XC-PAC Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It

More information