Connections, displays and operating elements C D

Size: px
Start display at page:

Download "Connections, displays and operating elements C D"

Transcription

1 GB /IP- REG-K Operating instructions Art. no. MTN For your safety ¼ DANGER Risk of fatal injury from electrical current. All work carried out on the device may only be performed by skilled electricians. The countryspecific regulations and the valid guidelines must be followed. ½ CAUTION Safety clearance must be guaranteed as per DIN- EN A distance of at least 4 mm must be maintained between individual cores of the 230 V cable and the line. E F G Connections, displays and operating elements A B C D A Connection of external power supply (12 V to 24 V AC / 12 V to 30 V DC) B Bus connecting terminal C Programming button D Programming LED (red) E LED display for (green): - lights up when bus voltage is present - flashes during telegram communication F LED display for LAN (green): - lights up when Ethernet connection is present - flashes during telegram communication G RJ 45 socket for connecting an Ethernet patch cable How to install the /IP- 1 First plug the /IP r on top of the DIN rail and then let it snap in below. Coupler function (/IP routing) The /IP r can work as a line or backbone coupler. In both cases the LAN (IP) is used as a backbone. The assignment of the physical address of the /IP r determines if the device works as a line coupler or a backbone coupler. If the physical address has the form x.y.0 (x, y: 1..15), the r works as a line coupler. If the physical address has the format x.0.0 (x: 1..15), it is a backbone coupler. Note: If the /IP r is used as a backbone coupler (x.0.0), no /IP r may be located topologically below it. For example, if a /IP r has the physical address 1.0.0, a /IP r with the address is not permitted. Note: If the /IP r is used as a line coupler (x.y.0), no /IP r may be located topologically above it. For example, if a /IP r has the physical address 1.1.0, a /IP r with the address is not permitted. The /IP r has a table and thus helps reduce the bus load. The table is automatically generated by the ETS. Because of the speed difference between Ethernet (10 Mbit/s) and (9.6 kbit/s), far more telegrams can be transmitted on the IP. If there several telegrams in a short row for the same line, they must be buffered in the r in order to avoid telegram losses. For this, the /IP r has memory for 150 telegrams (from IP to ). /IP r as line coupler LAN Switch ½ CAUTION Adjacent devices can be damaged. Devices installed with next to the switch actuator must have at least basic insulation. Getting to know the /IP r The /IP r enables telegrams to be forwarded between different lines via a LAN (IP) as a rapid backbone. The device can additionally serve as a programming interface in order to connect a PC with the bus (e.g. for ETS programming). The IP address can be assigned via a DHCP server or via manual configuration (ETS). The Internet protocols ARP, ICMP, IGMP, UDP/IP and DHCP are supported. The device operates in accordance with the net/ip specification using core, device management, tunnelling and routing. Power is supplied externally (12 V to 24 V AC / 12 V to 30 V DC) or alternatively via power over Ethernet (IEEE 802.3af). 2 Connect the. 230 V 4 mm 1 ¼ CAUTION Risk of fatal injury from electrical current. The device may become damaged. A safety clearance from the line to 230 V cables must be guaranteed. Always place the cable cover over the connecting terminal. 3 Connect the Ethernet patch cable to the RJ 45 socket. Note: The connection of an external power supply is only necessary if the switch used does not support a power over Ethernet. 4 Attach an external power supply if the switch used does not support a power over Ethernet IP /IP r as Backbone coupler LAN IP Switch IP IP V /07

2 /IP- backbone and line coupler Function as bus access (net/ip tunnelling) The /IP r can be used as an interface to the. The can be accessed from any point in the LAN. A second physical address must be assigned for this purpose. This is explained in the application description. LAN IP Switch IP Note on removal: To remove, prise out the shutter on the lower side A of the /IP r. Use a screwdriver for this. Then simply take the / IP r off the DIN rail. Removal: 3 Technical data Supply from: DC 24 V / approx. 10 ma External power supply Voltage: AC 12-24V DC 12-30V Power consumption: max. 800 mw Alternative power supply: Power over Ethernet Connections : Via two 1 mm pins for bus connecting terminal External power supply: Two screw terminals for the power supply LAN: A LAN connection RJ-45 Ambient temperature Operation: -5 C to +45 C Storage: -25 C to +55 C Transport: -25 C to +70 C Environment: The device is designed for use at elevations of up to 2000 m above sea level (MSL) Max. humidity: 93%, no moisture condensation Type of protection: IP 20 in accordance with EN Dimensions: 90x36x65 mm (HxWxD) Mounting width: 2 pitches EC guideline: 89/336/EEC 2 1 Starting up the /IP r 1 Load the physical address from the ETS into the /IP r via the. 2 Make the configuration settings in ETS and transfer them. 2 Schneider Electric Industries SAS If you have technical questions, please contact the Customer Care Center in your country. This product must be installed, connected and used in compliance with prevailing standards and/or installation regulations. As standards, specifications and designs develop from time to time, always ask for confirmation of the information given in this publication. V /07

3 / IP r 7125/1.0 / IP r 7125/1.0 Function This section lists the functional explanation of the parameters of the ETS application with their nominal values and default settings. General tab General Device name Support for unparameterised interfaces Monitoring for bus voltage failure IP address assignment /IP r REG-K enable enable manual automatic (DHCP) Device name: You can choose any name for the /IP r REG- K. The name may be at most 30 characters long. The name is used to identify individual devices in a network. The device name should be informative (e.g. /IP_r_line_1.1.x), so that when several / IP rs are used, each device can be uniquely identified and assigned to a line. Support for unparameterised interfaces: An interface with a physical address that does not match the line topology can be used (e.g. for startup). s:, enable Monitoring for bus voltage failure: If a failure of the is determined, this is reported on IP. The bus voltage recovery is reported in the same way. s:, enable IP address assignment: Automatic (DHCP): The IP address is automatically assigned via DHCP, i.e. no additional settings are necessary for it. In order for this function to be used, there must be a DHCP server located in the LAN (e.g. many DSL rs have an integrated DHCP server). Manual: Here the IP address, the subnetwork and the gateway IP address must be entered by hand. IP configuration tab IP routing multicast address: This address is used for routing telegrams to IP. The multicast IP address was reserved for this purpose (net/ip) by the IANA (Internet Assigned Numbers Authority). If a different multicast IP address is desired, it must be in the range between and IP address: This is the IP address of the /IP r REG-K. It is only displayed if the IP address assignment in the "General" tab is set to manual. IP subnetwork: The subnetwork mask is to be entered here. This mask allows the device to determine if a communication partner is located in the local network. If there is no partner in the local network, the device does not send the telegrams directly to the partner, but to the gateway, which takes over the routing. IP gateway address: The gateway's IP address is to be provided here. Note: If the /IP r is only used in the local LAN, the entry can remain. Example for assigning IP addresses: A PC should be used to access the /IP r. IP address of the PC: Subnetwork of the PC: The /IP r is located in the same local LAN, i.e. it uses the same subnetwork. The assignment of the IP address is limited by the subnetwork, i.e. in this example the IP address of the /IP r must be xx, where xx can be a number from 1 to 254 (except 30, which is already used). Make sure that no address is assigned twice. IP address of the /IP r: Subnetwork of the /IP r:

4 / IP r 7125/1.0 IP configuration 1 IP routing multicast address IP address If the IP address assignment in the "General" tab is set to manual: IP configuration 2 IP subnetwork IP gateway address Register routing ( -> IP) (main group 0 to 13): (main group 14 to 15): (main group 16 to 31): 0 255, 224 default setting 0 255, 23 default setting 0 255, 12 default setting No group telegram of these main groups is d to IP. All group telegrams of these main groups are d to IP independently of the table. This setting should be used only for test purposes. Here the table is used to check if the received group telegram is d to IP. No group telegram of the main groups 14 and 15 is d to IP. All group telegrams of the main groups 14 and 15 are d to IP. No group telegram of these main groups is d to IP. An additional page appears where the routing of the main groups 16 to 31 can be ed or in pairs. Note: The group addresses of the main groups 16 to 31 are reserved addresses that can be used in special applications (e.g. in Easy mode). These group addresses are not available in the ETS. Physically addressed telegrams: Broadcast telegrams: Acknowledgement (ACK) of group telegrams: Always: Only when routing: Acknowledgement (ACK) of physically addressed telegrams: Always: Only when routing: Answer with NACK: No physically addressed telegram is d to IP. All physically addressed telegrams are d to IP. The physical address is used to check if the received physically addressed telegram is d to IP. No received broadcast telegram is d to IP. All received broadcast telegrams are d to IP. An acknowledgement is always generated when group telegrams are received (from ). When group telegrams are received (from ), an acknowledgement is only generated in case of routing to IP. An acknowledgement is always generated when physically addressed telegrams are received (from ). When physically addressed telegrams are received (from ), an acknowledgement is only generated in case of routing to IP. Every physically addressed telegram received (from ) is answered with NACK (not acknowledge). That means communication with physically addressed telegrams on the corresponding line is no longer possible. The group communication (group telegrams) is not affected by it. This setting can be used to prevent manipulation attempts. Note: In the case of "Answer with NACK", the parameterisation must take place via IP. Routing ( -> IP) (Main group 0 to 13) (Main group 14 to 15) (Main group 16 to 31) Physically addressed telegrams Broadcast telegrams Acknowledgement (ACK) of group telegrams Acknowledgement (ACK) of physically addressed telegrams (see next page) always only when routing only when routing always Answer with NACK 4

5 / IP r 7125/1.0 If group telegrams (main group 16 to 31) in the "Routing (-> IP)" tab is set to : Group tel. 16 to 31 ( -> IP) (Main group 16 to 17) (Main group 18 to 19) (Main group 20 to 21) (Main group 22 to 23) (Main group 24 to 25) (Main group 26 to 27) (Main group 28 to 29) (Main group 30 to 31) Register routing (IP -> ) (main group 0 to 13): (main group 14 to 15): (main group 16 to 31): No group telegram of these main groups is d to. All group telegrams of these main groups are d to independently of the table. This setting should be used only for test purposes. Here the table is used to check if the received group telegram is d to. No group telegram of the main groups 14 and 15 is d to. All group telegrams of the main groups 14 and 15 are d to. No group telegram of this main group is d to. An additional page appears where the routing of the main groups 16 to 31 can be ed or in pairs. Note: The group addresses of the main groups 16 to 31 are reserved addresses that can be used in special applications (e.g. in Easy mode). These group addresses are not available in the ETS. Physically addressed telegrams: Broadcast telegrams: No physically addressed telegram is d to the. All physically addressed telegrams are d to the. The physical address is used to check if the received physically addressed telegram is d to the. No received broadcast telegram is d to the. All received broadcast telegrams are d to the. Repeat sending of group telegrams: Enable: In the event of an error, the received group telegram is not sent repeatedly to the. In the event of an error, the received group telegram is repeated up to three times. Repeat sending of physically addressed telegrams: Enable: In the event of an error, the received physically addressed telegram is not sent repeatedly to the. In the event of an error, the received physically addressed telegram is repeated up to three times. Repeat sending of broadcast telegrams: Enable: Routing (IP -> ) (Main group 0 to 13) (Main group 14 to 15) (Main group 16 to 31) In the event of an error, the broadcast telegram is not sent repeatedly to the. In the event of an error, the broadcast telegram is repeated up to three times. Physically addressed telegrams Broadcast telegrams Repeat sending of group telegrams Repeat sending of physically addressed telegrams Repeat sending of broadcast telegrams (see next page) release release release 5

6 / IP r 7125/1.0 If group telegrams (main group 16 to 31) in the "Routing (IP ->)" tab is set to : Group tel. 16 to 31 (IP -> ) (Main group 16 to 17) (Main group 18 to 19) (Main group 20 to 21) (Main group 22 to 23) (Main group 24 to 25) (Main group 26 to 27) (Main group 28 to 29) (Main group 30 to 31) Bus access (net/ip tunnelling) If the IP configuration of the /IP r REG-K is valid, it can be used as an interface to the. In order for this function to be used, the following steps should be followed in the ETS (from version 3.0c): In the ETS under Tools ->Options, select the Communication tab. Click the Configure interface button. The ETS Connection Manager opens. Create a new connection. Under Type, select net/ip. The ETS begins with the automatic search of all net/ip devices. All devices found are displayed. Select the required device. Create a second physical address: The /IP r REG-K needs a second physical address in order to access the. This second physical address is used only for bus access and is to be set as follows: In the ETS under Tools ->Options, select the Communication tab. Select a communication interface with type net/ip. Click the s button. The s window of the local interface opens. Enter an unused physical address here. Note: Make sure that this address is topologically in the same line but is not used by another device. If necessary, insert a dummy device in the ETS project to reserve this address. 6

Power Supply System KNX PS640-IP

Power Supply System KNX PS640-IP Power Supply System KNX PS640-IP with Ethernet Interface Installation and Adjustment Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70

More information

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions EN Operation and installation manual IP (Art. # 5212) Power supply with integrated IP Router and diagnosis functions Switch LAN IP 1.1.0 IP 2.1.0 1.1.1 1.1.7 2.1.1 2.1.7 1.1.2 1.1.8 2.1.2 2.1.8 1.1.3 1.1.9

More information

Technical Manual MDT IP Router

Technical Manual MDT IP Router 1/2012 Technical Manual MDT IP Router SCN-IP100.01 Table of contents 1 Introduction...3 1.1 Installation and connection...3 2.1 Coupler function...4 2.2 Bus access function (KNXnet/IP Tunneling)...6 3

More information

Product and Applications Description

Product and Applications Description IP N146/02 Product and Applications Description The IP N146/02 is a DIN rail mounted device. The device implements the KNXnet/IP standard and connects KNX/EIB lines via data networks using the Internet

More information

Operation and installation manual KNX IP Router. Application. Coupler function (KNXnet/IP Routing)

Operation and installation manual KNX IP Router. Application. Coupler function (KNXnet/IP Routing) EN Operation and installation manual Ref. 9018248B Compact bus powered Router between LAN/Ethernet and KNX bus Application The allows forwarding of telegrams between different lines (TP) through a LAN

More information

Technical Manual MDT IP Router

Technical Manual MDT IP Router 3/2015 Technical Manual MDT IP Router SCN-IP100.01 Table of contents 1 Introduction... 3 1.1 Installation and connection... 3 2.1 Coupler function... 4 2.2 Bus access function (KNXnet/IP Tunneling)...

More information

instabus KNX / EIB product documentation

instabus KNX / EIB product documentation Page: 1 of 21 System Product name: (R2) Design: REG (rail-mounted ) Article-no.: J: IPR 100 REG ETS search System s / / path: Issue: 05.03.2010 Functional description: This describes the with the release

More information

Power Supply System KNX PS640+IP

Power Supply System KNX PS640+IP Power Supply System KNX PS640+IP with Bus Functions and Ethernet Interface Item Number 70145 Installation and Adjustment Elsner Elektronik GmbH Control and Automation Technology Sohlengrund 16 75395 Ostelsheim

More information

Contents 1. Summary

Contents 1. Summary Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R KNX IP Router User manual-ver.1 BNIPR-00/00.1 KNX/EIB Intelligent Installation Systems Contents 1. Summary------------------------------------------------------------------------------------------------------------------------------

More information

Product and Application Description

Product and Application Description Technical Product-Information Product and Application Description The IP Gateway KNX-BACnet N 143 is is a DIN rail mounted device connecting a KNX installation with a system using BACnet/IP communication.

More information

Connections, displays and operating elements

Connections, displays and operating elements KNX DALI gateway REG-K/1/16(64)/64MTN680191 Merten2005V6801-561-0007/08 GB KNX DALI gateway REG-K/1/16(64)/64 Operating instructions MTN680191 For your safety Connections, displays and operating elements

More information

IP gateway, MDRC IG/S 1.1, GH Q R0001

IP gateway, MDRC IG/S 1.1, GH Q R0001 , GH Q631 0067 R0001 The IP gateway IG/S is the interface The IP address of the IG/S can be between EIB / KNX installations and IP fixed or received from a DHCP server. CDC 071 130 F0003 networks. Data

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016.

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016. IP- 001031 Table of contents Use of the application program 1 1. Functional description 1 2. Communication objects 4 3. s 4 General 4 Routing (Bus > IP) 4 Routing (IP > Bus) 5 IP 5 Setting the additional

More information

Connections, displays and operating elements. Hand 1 / / 4

Connections, displays and operating elements. Hand 1 / / 4 GB Blind actuator REG-K/4x24/6 with manual mode Operating instructions Hand Connections, displays and operating elements I H 1 2 1 2 1 2 1 2 Hand 3 4 3 4 3 4 3 4 B A C D E ½ CAUTION The blind actuator

More information

Application program usage. Functional description. instabus EIB Application Program Description. December IP-Router

Application program usage. Functional description. instabus EIB Application Program Description. December IP-Router Application program usage Product family: Product type: Manufacturer: Name: Order-No.: System devices IP- Siemens Functional description IP N146 5WG1 146-1AB01 The IP N146 is a DIN rail mounted device.

More information

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli)

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli) Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli) EAE Technology www.eaetechnology.com CONTENTS 1 General...3 1.1 Communication objects...4 1.2 IPR100 as programming interface...4 1.3 Tunnelling...4

More information

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017 DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION Author: Peter Hauner Last modification: 8 September 2017 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska Details, modifications

More information

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29 Linienkoppler S KNX Line coupler S KNX Line coupler S KNX 9070880 Status: March 16 (Subject to change) Page 1 of 29 KNX Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Structure

More information

Operation and installation manual KNX IP BAOS 774. KNX IP BAOS 774 as application specific Gateway BAOS SDK. Application. Installation and Connection

Operation and installation manual KNX IP BAOS 774. KNX IP BAOS 774 as application specific Gateway BAOS SDK. Application. Installation and Connection EN Operation and installation manual KNX IP BAOS 774 (Art. # 5263) Compact bus powered Interface and ObjectServer between LAN and KNX bus Protocol descriptions can be downloaded at the KNX IP BAOS 774

More information

Operation and installation manual KNX IP BAOS 773. KNX IP BAOS 773 as application specific Gateway BAOS SDK. Application. Installation and Connection

Operation and installation manual KNX IP BAOS 773. KNX IP BAOS 773 as application specific Gateway BAOS SDK. Application. Installation and Connection EN Operation and installation manual KNX IP BAOS 773 (Art. # 5262) Compact bus powered Interface and ObjectServer between LAN and KNX bus KNX IP BAOS 773 as application specific Gateway To connect to non-knx

More information

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification:

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification: DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION Authors: Manouchehr Ghahramanian Golzar, Peter Hauner Last Modification: 2017-03-02 2001-2017 Apricum d.o.o. Mažuranićeva 4, 21312 Podstrana, Hrvatska

More information

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011 Technical Data 2CDC502086D0201 Product description IP Router 3.1.1 is the interface between KNX installations and IP networks. It can be used as a line coupler or area coupler and can utilize the local

More information

Application program usage. Functional description. instabus EIB Application Program Description. March IP-Router

Application program usage. Functional description. instabus EIB Application Program Description. March IP-Router IP- 001002 Application program usage Product family: Product type: Manufacturer: Name: Order-No.: System devices IP- Siemens Functional description IP N146 5WG1 146-1AB01 The IP N146 is a DIN rail mounted

More information

KNX IP router Order No

KNX IP router Order No KNX Product documentation Status of the documentation: 12.01.2018 KNX IP router Order No. 2167 00 KNX Product documentation Table of contents 1 Productdefinition... 4 1.1 Product catalogue... 4 1.2 Accessories:...

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

CP BACNET Function

CP BACNET Function CP 343-1 BACNET Function The CP 343-1 BACnet independently handles data traffic via Industrial Ethernet and BACnet protocol. The module has its own processor and can be put into service directly using

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date: Documentation Sixteen channel digital output module with D-Sub Connector Version: Date: 2.0.0 2017-11-20 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety

More information

Use of the application program

Use of the application program Table of contents Use of the application program 1 1. Functional description 1 2. Communication objects 3 3. Parameters 3 IP Settings 3 Setting the additional individual address of the IP Interface with

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Product and functional description

Product and functional description Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect

More information

USER MANUAL CU-DIN IPRT KNX EC MA

USER MANUAL CU-DIN IPRT KNX EC MA CU-DIN IPRT KNX EC10430527 MA00653502 Table of contents 1 Description...3 2 Safety instructions...4 3 Product Funtion...5 3.1 Communication objects... 5 3.2 CU-DIN IPRT KNX as programming interface...

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date: Documentation Sixteen Channel Digital Output Module with D-Sub Connector Version: Date: 2.0 2016-08-03 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety

More information

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date: Documentation KM2604 and KM2614 Four channel relay module Version: Date: 2.1.0 2017-12-01 Tabel of contents Tabel of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH Anybus Communicator IIoT STARTUP GUIDE ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011 Technical data 2CDC509078D0201 ABB i-bus KNX Product description The device provides extensive logic functions. The logic is defined via a graphic editor integrated in the ETS. Up to 3,000 logic gates

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum: 471 M41 H31 Betriebsanleitung MSS-Zentraleinheit Operating instructions MSS central control unit Notice d'utilisation Unité centrale MSS Istruzioni d'impiego Centralina MSS Datum: 06.09.2005 , Datum: 06.09.2005

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

ENGLISH KNXCONVERTER PARLEZ VOUS ASCII?

ENGLISH KNXCONVERTER PARLEZ VOUS ASCII? ENGLISH PARLEZ VOUS ASCII? PARLEZ VOUS ASCII? Included KNX IP router functionality The converts KNX telegrams into ASCII code and vice versa. It makes it easy to integrate third-party applications. The

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

CP ADVANCED. Function

CP ADVANCED. Function CP 343-1 ADVANCED Function The CP 343-1 Advanced independently handles data traffic over Industrial Ethernet. The module has its own processor and can be put into service directly using the unique preset

More information

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011 , 2CDG 110 15x R0011 SA/S 12.6.1.1 2CDC 071 033 S0012 The 6 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are suitable for

More information

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions

More information

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date: Documentation CU20xx, CU22xx Ethernet Switch Version: Date: 2.1 2017-12-18 CU20xx, CU22xx - Product overview 1 CU20xx, CU22xx - Product overview CU2005 [} 8] - 5 RJ-45-Ethernet-Ports CU2008 [} 8] - 8

More information

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL

FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI F1144/ 03 INSTALLATION MANUAL FIELDBUS TECHNOLOGY ETHERNET- PROFIBUS- INTERFACE PB-XEPI INSTALLATION MANUAL F1144/ 03 2 Installation PB-XEPI D301144 0509 Content About this "Installation manual"...5 Intended use...5 Explanation of

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Push Button Interface UP 220D31

Push Button Interface UP 220D31 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation

More information

u::lux NetCon & u::lux NetCon Power

u::lux NetCon & u::lux NetCon Power u::lux NetCon & u::lux NetCon Power Manual www.u-lux.com office@u-lux.com Tel: +43/662/450 351-13 Fax: +43/662/450 351-16 u::lux GmbH Rechtes Salzachufer 42 5020 Salzburg Austria Contents General Information...

More information

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH

Installation Manual TH LINK PROFINET. Version: EN Copyright 2014 Softing Industrial Automation GmbH Installation Manual TH LINK PROFINET Version: EN-201410-1.00 Copyright 2014 Softing Industrial Automation GmbH Disclaimer of liability The information contained in these instructions corresponds to the

More information

Push button UP 287, 4 - fold

Push button UP 287, 4 - fold Product DELTA profil DELTA style Push button 1-fold pearl grey 5WG1 241-2AB01 titanium white 5WG1 285-2AB11 titanium white 5WG1 241-2AB11 basalt black 5WG1 285-2AB21 anthracite 5WG1 241-2AB21 titanium

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

584 5WG AB_1 DELTA

584 5WG AB_1 DELTA Product DELTA profil DELTA style DELTA ambiente Display and control unit 5WG1 585-2AB01 pearl grey 5WG1 585-2AB11 titanium white 5WG1 585-2AB21 anthracite 5WG1 585-2AB71 silver 5WG1 585-2AB11 titanium

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device Product and Applications Description With the ETS (EIB Tool Software) the application program is selected, its parameters and addresses are assigned appropriately, and downloaded to the interface AP 146.

More information

ABB GPG Building Automation, November 2016 ABB i-bus KNX Logic Controller ABA/S ABB Group November 10, 2016 Slide 1

ABB GPG Building Automation, November 2016 ABB i-bus KNX Logic Controller ABA/S ABB Group November 10, 2016 Slide 1 ABB GPG Building Automation, November 2016 ABB i-bus KNX Logic Controller ABA/S 1.2.1 ABB Group November 10, 2016 Slide 1 Logic Controller ABA/S 1.2.1 Overview The new Logic Controller is an extremely

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161 Technical Data 9AKK107045A4913 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

IF-80x Outdoor Terminal

IF-80x Outdoor Terminal 95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

Gateway configuration manual IP - KNX EK-BE1-TP

Gateway configuration manual IP - KNX EK-BE1-TP IP - KNX EK-BE1-TP Index Scope of the document... 3 1 Product description... 3 1.1 Main functions... 4 1.2 Technical data... 4 1.3 Supply... 5 1.4 System requirements for configuration software... 5 1.5

More information

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date: Documentation KM10xx Terminal Modules with Digital Inputs Version: Date: 3.1.0 2017-01-23 Product overview KM10xx Product overview KM10xx KM1002, KM1012 [} 11] - 16 inputs, input filter 3 or 0.2 ms KM1004,

More information

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions Smart Control IP Art. No. SC 1000 IP Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

Manual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No.

Manual English. for the Devices of the MVK-MPNIO Safety Series MVK-MPNIO F DI16/8 Art. No and MVK-MPNIO F DI8/4 F DO4 Art. No. Introduction For Your Safety Description Installation Startup Configuration Run Mode Maintenance and Cleaning Manual English for the Devices of the Series MVK-MPNIO F DI16/8 Art. No. 55560 and MVK-MPNIO

More information

Product documentation

Product documentation Product documentation Standard push-button module with BCU, 2-gang ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 D-58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-1 89 E-mail: mail.info@jung.de

More information

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. : Blind actuator 4-gang 24 V DC Order-No. : 2154 00 Blind actuator 4-gang 230 V AC Order-No. : 2160 00 Blind actuator 2-gang 230 V AC Order-No. : 2152 00 Blind actuator 4-gang 230 V AC Order-No. : 1039 00

More information

Product documentation

Product documentation Product documentation Standard push-button module with BCU, 4-gang ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 D-58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-1 89 E-mail: mail.info@jung.de

More information

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP Digital Concepts GmbH 27.07.2016 Contents 1. Introduction... 3 2. Functionality... 4 3. Package Contents... 4 4. Requirements... 5 5. Ports... 5 6. Mounting...

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

IP Router KNX Product manual

IP Router KNX Product manual Product manual Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Notes... 4 1.2 Product and functional overview... 5 1.2.1 Monitoring for bus voltage failure... 6 1.2.2 Overview

More information

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011 Technical Data 2CDC505168D0201 ABB i-bus KNX Product description The Analogue Actuator converts telegrams received via KNX into analog output signals. The device has four outputs. The analog outputs can

More information

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date: Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

DELTA profil wall switch, single UP 241/2 5WG AB_2

DELTA profil wall switch, single UP 241/2 5WG AB_2 UP 241/2 5WG1 241-2AB_2 UP 241/3,with status LED 5WG1 241-2AB_3 UP 243/2 5WG1 243-2AB_2 UP 243/3,with status LED 5WG1 243-2AB_3 UP 245/2 5WG1 245-2AB_2 UP 245/3,with status LED 5WG1 245-2AB_3 UP 245/4,with

More information

COMTRAXX COM460IP. BMS-Ethernet-Gateway

COMTRAXX COM460IP. BMS-Ethernet-Gateway COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP_D00023_03_D_XXEN/11.2015 COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX AC/S Application Controller ABB i-bus KNX AC/S 1.2.1 Application Controller Description of product Automation controller with pre-defined automation modules for comprehensive heating, ventilation and air conditioning automation (HVAC

More information

6173 AG GJB A0138

6173 AG GJB A0138 0073-1-6048 24661 ABB ibus EIB Combi actuator 6173 AG-101-500 GJB 000 6151 A0138 with 4-gang binary input for use as: 4-gang switching actuator 2x2-gang shutter actuator 2-gang switching-/1x2-fach-shutter

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Date Revision Change(s) 29/07/ First version

Date Revision Change(s) 29/07/ First version Revision overview Revision overview Date Revision Change(s) 29/07/2016 0 First version Copyright 2016 Indu-Sol GmbH We reserve the right to amend this document without notice. We continuously work on further

More information

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date: Documentation KM2002, KM2004, KM2008 Terminal modules with digital outputs, 24 V, 0.5 A Version: Date: 3.2.0 2017-01-23 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation...

More information

- Pt100 temperature relay for up to 12 sensors with electric 10 MBit/s Ethernet interface Configuration through Web server

- Pt100 temperature relay for up to 12 sensors with electric 10 MBit/s Ethernet interface Configuration through Web server ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 54-, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching

More information

Operating Instructions. DALI-Gateway

Operating Instructions. DALI-Gateway Operating Instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Failure to observe the instructions may cause damage to the device and result

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information