Symantec S500 Network Interface Card Options and Installation

Size: px
Start display at page:

Download "Symantec S500 Network Interface Card Options and Installation"

Transcription

1 Symantec S500 Network Interface Card Options and Installation Guide Revision: 4/28/2017

2 2

3 Legal Notices Copyright 2017 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo are trademarks or registered trademarks of Symantec Corp. or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This document is provided for informational purposes only and is not intended as advertising. All warranties relating to the information in this document, either express or implied, are disclaimed to the maximum extent allowed by law. The information in this document is subject to change without notice. THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. SYMANTEC CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE. SYMANTEC CORPORATION PRODUCTS, TECHNICAL SERVICES, AND ANY OTHER TECHNICAL DATA REFERENCED IN THIS DOCUMENT ARE SUBJECT TO U.S. EXPORT CONTROL AND SANCTIONS LAWS, REGULATIONS AND REQUIREMENTS, AND MAY BE SUBJECT TO EXPORT OR IMPORT REGULATIONS IN OTHER COUNTRIES. YOU AGREE TO COMPLY STRICTLY WITH THESE LAWS, REGULATIONS AND REQUIREMENTS, AND ACKNOWLEDGE THAT YOU HAVE THE RESPONSIBILITY TO OBTAIN ANY LICENSES, PERMITS OR OTHER APPROVALS THAT MAY BE REQUIRED IN ORDER TO EXPORT, RE-EXPORT, TRANSFER IN COUNTRY OR IMPORT AFTER DELIVERY TO YOU. Symantec Corporation 350 Ellis Street Mountain View, CA

4 Contents Legal Notices 3 Safety Warnings and Cautions 5 Power and Electrical Warnings 5 CAUTION 5 System Access Warnings 5 CAUTION 5 To avoid personal injury or property damage, the following safety instructions apply whenever accessing the inside of the product: 5 CAUTION 6 CAUTION 6 Cooling and Airflow Warning 6 Electrostatic Discharge (ESD) Warning 6 CAUTION 6 Network Interface Card Options 7 Install an option card into Slot 1 or 2 18 Install an option card into Slot 3 or 4 20 Install an option card into Slot 5 or 6 24 Install an option card into Slot 7 27 Open the S500 Series Center Cover 29 Remove the S500 Series Rear Cover 30 Remove the S500 Series PCIe Expansion Module 31 Install the S500 Series PCIe Expansion Module 32 4

5 Safety Warnings and Cautions Caution: This product is designed to work with power systems having a grounded neutral. To reduce the risk of electric shock, do not plug this product into any other type of power system. Contact a qualified electrician if you are not sure what type of power is supplied to your building. Power and Electrical Warnings CAUTION The power button, indicated by the stand-by power marking, DOES NOT completely turn off the system AC power. 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. If your system uses more than one AC power cord, make sure all AC power cords are unplugged before you open the chassis, or add or remove any non hotplug components. The power supply in this product contains no user-serviceable parts. Do not open the power supply. Hazardous voltage,current, and energy levels are present inside the power supply. Return to manufacturer for servicing. To avoid risk of electric shock, turn off the appliance and disconnect the power cord, telecommunications systems, networks, and modems attached to the appliance before opening it. The power cord set included with the appliance meets the requirements for use in the country of purchase. Use the power cord that shipped with the appliance. If this appliance is to be used in another country, purchase an AC power cord set that is approved for use in that country (18 AWG recommended). The power cord must be rated for the product and for the voltage and current marked on the product's electrical ratings label. The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product. In addition, the cross-sectional area of the wires must be a minimum of 1.00mmð or 18AWG or 18AWG, and the length of the cords must be between 1.8m (6 feet) and 3.6m (12 feet). System Access Warnings CAUTION To avoid personal injury or property damage, the following safety instructions apply whenever accessing the inside of the product: Turn off all peripheral devices connected to this product. Turn off the system by safety shutting down the appliance. Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. Disconnect all cables and telecommunication lines that are connected to the system. Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners. 5

6 Do not access the inside of the power supply. There are no serviceable parts in the power supply. Return to manufacturer for servicing. Power down the server and disconnect all power cords before adding or replacing any non hot-plug component. When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing the power supply from the server. CAUTION If the server has been running, any installed processor(s) and heat sink(s) may be hot. Unless you are adding or removing a hot-plug component, allow the system to cool before opening the covers. To avoid the possibility of coming into contact with hot component(s) during a hot-plug installation, be careful when removing or installing the hot-plug component(s). CAUTION To avoid injury do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the system without the fan guard in place. Cooling and Airflow Warning Carefully route cables as directed to minimize airflow blockage and cooling problems. For proper cooling and airflow, operate the system only with the chassis covers installed. Operating the system without the covers in place can damage system parts. To install the covers: 1. Check first to make sure you have not left loose tools or parts inside the system. 2. Check that cables, add-in boards, and other components are properly installed. 3. Attach the covers to the chassis according to the product instructions. Electrostatic Discharge (ESD) Warning CAUTION ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground- any unpainted metal surface -- on your server when handling parts. Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface 6

7 Network Interface Card Options The following lists the option cards that are available for the S500-based appliances. The low-profile option cards can be installed into any of the PCIe slots, including the on-board PCIe slots and the PCIe expansion module slots. Full-height cards, with a system maximum of 2, can only be installed in the PCIe expansion module, slots 3 and 4. Option cards are shipped with a pre-installed bracket that might not be compatible with your appliance or desired slot usage. You must replace the bracket with the necessary version before installing an option card. Be sure to verify that your product supports the option card before installation. S500 Series-based appliances equipped with a single CPU cannot use slots 5, 6, and 7. Please select the option card that you wish to install: Review the "Safety Warnings and Cautions" on page 5 before servicing your appliance. Do not install any NIC (network interface cards) which are not explicitly supported by the appliance. Installation and use of unauthorized NICs might damage the appliance and will invalidate your warranty! Network Card Supported Appliances Description Expansion Slot Usage Installation NIC-S500-2x10G-PT ProxySG PacketShaper ASG 2-port 10GBASE-T Pass-through (click for details) All expansion slots I'd like to install the option card in: Slot 1 or 2 Slot 7 Slot 3 or 4 (PCIe expansion module) Slot 5 or 6 (PCIe expansion module) NIC-S500-4xGigE-PT- Fiber ProxySG PacketShaper ASG 4-port 1000BASE-SX Pass-through, Fiber, Small form Factor Pluggable (LC) (click for details) Only installable in slots 3 or 4. I'd like to install the option card in: Slot 3 or 4 (PCIe expansion module) NIC-S500-4xGigE-PT ProxySG PacketShaper ASG 4-port 1000BASE-T Passthrough (click for details) All expansion slots I'd like to install the option card in: Slot 1 or 2 Slot 7 Slot 3 or 4 (PCIe expansion module) Slot 5 or 6 (PCIe expansion module) 7

8 Network Card Supported Appliances Description Expansion Slot Usage Installation NIC-S500-2x10G 2-port 10GBASE-T Nonbypass NIC-S500-2x10G-PT- SR-Fbr NIC-S500-2x10G-PT- LR-Fbr NIC-S500-4xGigE-LX- Fiber) ProxySG Malware Analysis ASG ProxySG PacketShaper ASG ProxySG PacketShaper ASG ProxySG PacketShaper ASG (click for details) 2-port 10GBASE-SR Pass-Through,10 Gigabit (SFP+) (click for details) 2-port 10GBASE-LR Pass-Through, 10 Gigabit (SFP+) (click for details) 4-port 1000BASE-LX Single Mode, Passthrough, Fiber, LC Connector All expansion slots I'd like to install the option card in: Slot 1 or 2 Slot 7 Slot 3 or 4 (PCIe expansion module) Slot 5 or 6 (PCIe expansion module) All expansion slots I'd like to install the option card in: Slot 1 or 2 Slot 7 Slot 3 or 4 (PCIe expansion module) Slot 5 or 6 (PCIe expansion module) All expansion slots I'd like to install the option card in: Only installable in slots 3 or 4. Slot 1 or 2 Slot 7 Slot 3 or 4 (PCIe expansion module) Slot 5 or 6 (PCIe expansion module) I'd like to install the option card in: Slot 3 or 4 (PCIe expansion module) 8

9 The 10 Gigabit Ethernet bypass NIC cards [NIC-S500-2x10G_PT / NIC-S400-2x10G_PT] are PCIe x8 network adapters containing two copper 10 Gigabit interfaces. Key Features WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_ parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} IEEE Standard / Network topology: Copper 10Gigabit Ethernet, 10GBASE-T, IEEE 802.3an Gigabit Ethernet, 1000Base-T 100 Mb Ethernet : 100BASE- TX Data Transfer Rate: 20 Gb/s, 2000Mb/s and 200 Mb/s in full duplex mode per port. Cables and Operating distance: 100Base-Tx Category 5 maximum 50m* 1000Base-T Category 5E maximum 50m* 10GBase-T Category 6A maximum 50m** Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.1 (5GT/s) Board Size: mm X 68.91mm (6.60 X ) PCI Express Card Type: X8 Lane PCI Express Voltage: +12V ± 8% PCI Connector: Gold Finger - X8 Lane Controller: Intel x540 Holder: Metal Bracket I/O: RJ45 Weight: 170gr (5.997oz) Power Consumption: 18 W, 1.5 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode) W, 0.87 A at 12V: Typical all ports operate at 1Gb/s, (Normal Mode) W, 0.63 A at 12V: Typical all ports operate at 100Mb/s, (Normal Mode) W, 0.74 A at 12V: Typical Bypass Mode W, 0.74 A at 12V: Typical Disconnect** Mode W, 0.68 A at 12V: Typical No link at all ports LEDs: (2) LED per port Upper (Left) LED: Link /ACT: Turns on link, blinks on activity (green) Lower (Right) LED: Speed / Bypass / Disconnect* Link of 1Gb/s: Turns on link (yellow) Link of 10Gb/s: Turns on link (green) Bypass: Blink (Green) on Bypass Disconnect* : Blink (Yellow) *Theoretical Distance Defined as half a distance as stated by the IEEE standard **Theoretical Distance Defined as half a distance as stated by the IEEE 802.3an standard LEDs location: LEDs are located in the RJ45 connector port. Connector: (2) Shielded RJ-45 9

10 The quad port Gigabit Ethernet bypass NIC cards [NIC-S500-4xGigE-PT-Fiber / NIC-S400-4xGigE-PT-Fiber] are PCIe x4 network adapters containing four fiber Gigabit interfaces, based on a single chip, non-bridged GBE controller. Key Features Fiber Gigabit Ethernet 1000Base-SX:: Independently Fiber Gigabit Ethernet channel/s support Gigabit Ethernet 1000Base-SX. Small Form Factor (SFF) LC Connectors. WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} IEEE Standard / Network topology: Fiber Gigabit Ethernet, 1000Base-SX (850nM) Full duplex / Simplex: Support both Simplex & Full duplex operation in all operating speeds Auto negotiation: Auto-negotiation between Full duplex and simplex operations and between 10Mb/s 100Mb/s speeds and duplex 1000Mb/s. Data Transfer Rate: 2000Mbit/s in full duplex mode per port Cables and Operating distance: Multimode fiber - 137m maximum at 62.5 um * Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.1 (5GT/s) Board Size: mm X mm (6.60 X ) PCI Express Card Type: X4 Lane PCI Express Voltage: +3.3V +-9%, +12V +- 8% PCI Connector: Gold Finger - X4 Lane Controller: Intel i350am4 Holder: Metal Bracket I/O: LC Weight: 330g (11.641oz) Power Consumption: 0.40A, 4.8W at 12V: Typical all ports operate at 1000Mb/s. 0.40A, 4.8W at 12V: Typical No link at all ports. 0.38A, 4.56W at 12V: Bypass Mode. 0.38A, 4.56W at 12V: Disconnect Mode. LEDs: (1) LED per port Link/ACT: Blinks on activity (green). Turns on link (green). Bi-color LED per Bypass pair: BYPASS: Turns on Green on Bypass Disconnect : Turns on Yellow on Disconnect Normal: Off LEDs location: LEDs are located on the PCB, visible via holes in the metal bracket holder Connector: (4) LC *Theoretical Distance Defined as half a distance as stated by the IEEE standard 10

11 The quad port Gigabit Ethernet bypass NIC cards [NIC-S500-4xGigE-PT / NIC-S400-4xGigE-PT] are PCIe x4 network adapters containing four copper Gigabit interfaces, based on a single chip, non-bridged GBE controller. Key Features Copper Gigabit Ethernet 1000Base-T: Independently copper Gigabit Ethernet channels support four Gigabit Ethernet (1000Base-T), Fast Ethernet (100Base-Tx) and Ethernet (10Base-T). Triple speed 1000Mbps (1000Base- T), 100 Mbps (100Base-Tx) and 10 Mbps (100Base-T) operation. Nway auto negotiation automatic sensing and switching between 1Gbps full duplex and 100 / 10 Mbps operations Simplex or Full Duplex. RJ-45 female connectors. WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_ parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} IEEE Standard / Network topology: Gigabit Ethernet, 1000Base-T Fast Ethernet, 100Base-TX Ethernet, 10Base-T Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.1 (5GT/s) Board Size: mm X 68.91mm (6.60 X ) PCI Express Card Type: X8 Lane PCI Express Voltage: +12V ± 8% PCI Connector: Gold Finger - X8 Lane Controller: Intel i350am4 Holder: Metal Bracket I/O: RJ45 LEDs: (2) LED per port Link / Act Led: Turn on any Link speed, Blinks on Activity (green) Speed/Bypass/Disconnect (Bi-color) Led: 1000Mb/s: Turns on Yellow 100Mb/s: Turns on Green. 10Mb/s: Turns off Disconnect: Blink Yellow Bypass: Blink Green LEDs location: LEDs are integrated on RJ-45 connector Connector: (4) Shielded RJ-45 11

12 Key Features Technical Specifications Full duplex / Simplex: Support both Simplex & Full duplex operation in all operating speeds Auto negotiation: Auto-negotiation between Full duplex and simplex operations and between 10Mb/s 100Mb/s speeds and duplex 1000Mb/s. Data Transfer Rate: 1000 Mb/s, 100 Mb/s and 10 Mb/sec in simplex mode per port. 2000Mb/s 200 and 20 Mb/s in full duplex mode per port. Cables and Operating distance: 10Base-T Category 3, 4, or 5 maximum 50m * 100Base-Tx Category 5 maximum 50m * 1000Base-T Category 5E maximum 50m * *Theoretical Distance Defined as half a distance as stated by the IEEE standard 12

13 The 10 Gigabit Ethernet PCIe non-bypass NIC cards [NIC-S500-2x10G / NIC-S400-2x10G] contain two copper 10 Gigabit interfaces. Key Features IEEE Standard / Network topology: Copper 10Gigabit Ethernet, 10GBASE-T, IEEE 802.3an Gigabit Ethernet, 1000Base-T 100 Mb Ethernet : 100BASE- TX Data Transfer Rate: 20 Gb/s, 2000Mb/s and 200 Mb/s in full duplex mode per port. Cables and Operating distance: 100Base-Tx Category 5 maximum 100m 1000Base-T Category 5E maximum 100m 10GBase-T Category 6A maximum 100m Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.1 (5GT/s) Board Size: 251.4mm X 68.91mm (6.0 X ) PCI Express Card Type: X8 Lane PCI Express Voltage: +12V ± 8% PCI Connector: Gold Finger - X8 Lane Controller: Intel x540 Holder: Metal Bracket I/O: RJ45 Weight: 130g Power Consumption: W, 1.19 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode) W, 0.66 A at 12V: Typical all ports operate at 1Gb/s, (Normal Mode) W, 0.42 A at 12V: Typical all ports operate at 100Mb/s, (Normal Mode) W, A at 12V: Typical No link at all ports LEDs: (2) LED per port Speed LED: Link of 1Gb/s: Turns on link (yellow) Link of 10Gb/s: Turns on link (green) Link /ACT LED: Turns on link, blinks on activity (green) LEDs location: LEDs are located in the RJ45 connector port. Connector: (2) Shielded RJ-45 13

14 The dual port fiber 10 Gigabit Ethernet bypass NIC cards [NIC-S500-2x10G_PT_SR_fbr / NIC-S400-2x10G_ PT_SR_fbr] are PCIe x8 network adapters containing two fiber (SR) 10 Gigabit interfaces. Key Features 10 Gigabit Fiber Ethernet port supports 10GBASE-SR (850nM LAN PHY) 10Gigabit Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.0 (5GT/s) Board Size: mm X 68.91mm (6.60 X ) 850nM Small form Factor Pluggable (SFP+) PCI Express Card Type: X8 Lane PCI Express Voltage: +12V ± 8% WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_ parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} IEEE Standard / Network topology: Fiber 10 Gigabit Ethernet, 10GBase-SR (850nM) Data Transfer Rate: GBd Cables and Operating distance: PCI Connector: Gold Finger - X8 Lane Controller: Intel 82599ES Holder: Metal Bracket I/O: SR Weight: 200g (7.055Oz) Power Consumption: 6.6 W, 0.55 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode) W, 0.51 A at 12V: Typical Bypass Mode W, 0.53 A at 12V: Typical No link at all ports Multimode fiber: 62.5um, 160MHz/Km 26m 62.5um, (OM1)200MHz/Km 33m 50um, 400MHz/Km 66m 50um, (OM2)500 MHz/Km 82m 50um, (OM3)2000MHz/Km 300m 14

15 Key Features Optical Output Power: Normal Mode (Bypass Off): Typical: -3.1dBm (TX Switch Normal Fiber LC/LC) Minimum: -7.3 dbm Technical Specifications LEDs: (2) LED per port Link: Turns on Blue on 10G link. ACT: Blinks on activity (green). Bi-color LED per Bypass pair: BYPASS: Turns on Green on Bypass Disconnect : Turns on Yellow on Disconnect Normal: Off Optical Receive Sensitivity: LEDs location: LEDs are located on the PCB, visible via holes in the metal bracket holder Connector: (2) SR Normal Mode (Bypass Off) Insertion Loss: Typical: dbm Maximum: -11 dbm Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) (LCfiber- switch- LC) Typical: 0.39 db (From RX to TX) Maximum 1.6 db 15

16 The dual port fiber 10 Gigabit Ethernet bypass NIC cards [NIC-S500-2x10G_PT_LR_fbr / NIC-S400-2x10G_ PT_LR_fbr] are PCIe x8 network adapters containing two fiber (LR) 10 Gigabit interfaces. Key Features 10 Gigabit Fiber Ethernet port supports 10GBASE-LR (1310nM LAN PHY) Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.0 (5GT/s) Board Size: mm X 68.91mm (6.60 X ) WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_ parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} IEEE Standard / Network topology: Fiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY) Data Transfer Rate: GBd Cables and Operating distance: Single- Mode: 10000m at 9um PCI Express Card Type: X8 Lane PCI Express Voltage: +12V ± 8% PCI Connector: Gold Finger - X8 Lane Controller: Intel 82599ES Holder: Metal Bracket I/O: LC Weight: 200g (7.055oz) Power Consumption: 6.6 W, 0.55 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode) W, 0.51 A at 12V: Typical Bypass Mode W, 0.53 A at 12V: Typical No link at all ports Optical Output Power: Normal Mode (Bypass Off): Minimum: -5.2 dbm Optical Receive Sensitivity: Normal Mode (Bypass Off) Maximum: dbm Insertion Loss: Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) (LC- fiber- switch- LC) Maximum 0.5 db LEDs: (2) LED per port Link: Turns on Blue on 10G link. ACT: Blinks on activity (green). Bi-color LED per Bypass pair: BYPASS: Turns on Green on Bypass Disconnect : Turns on Yellow on Disconnect Normal: Off LEDs location: LEDs are located on the PCB, visible via holes in the metal bracket holder Connector: (2) LC 16

17 The quad port Gigabit Ethernet bypass NIC cards [NIC-S400-4xGigE-LX-Fiber / NIC-S200-4xGigE-LX-Fiber] are PCIe x4 network adapters containing four fiber Gigabit interfaces, based on a single chip, non-bridged GBE controller. Key Features Fiber Gigabit Ethernet 1000Base-SX:: Independently Fiber Gigabit Ethernet channel/s support Gigabit Ethernet 1000Base-SX. Small Form Factor (SFF) LC Connectors. WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} IEEE Standard / Network topology: Fiber Gigabit Ethernet, 1000Base-SX (850nM) Full duplex / Simplex: Support both Simplex & Full duplex operation in all operating speeds Auto negotiation: Auto-negotiation between Full duplex and simplex operations and between 10Mb/s 100Mb/s speeds and duplex 1000Mb/s. Data Transfer Rate: 2000Mbit/s in full duplex mode per port Cables and Operating distance: Multimode fiber - 137m maximum at 62.5 um * Technical Specifications Interface Standard: PCI-Express Base Specification Revision 2.1 (5GT/s) Board Size: mm X mm (6.60 X ) PCI Express Card Type: X4 Lane PCI Express Voltage: +3.3V +-9%, +12V +- 8% PCI Connector: Gold Finger - X4 Lane Controller: Intel i350am4 Holder: Metal Bracket I/O: LC Weight: 330g (11.641oz) Power Consumption: 0.40A, 4.8W at 12V: Typical all ports operate at 1000Mb/s. 0.40A, 4.8W at 12V: Typical No link at all ports. 0.38A, 4.56W at 12V: Bypass Mode. 0.38A, 4.56W at 12V: Disconnect Mode. LEDs: (1) LED per port Link/ACT: Blinks on activity (green). Turns on link (green). Bi-color LED per Bypass pair: BYPASS: Turns on Green on Bypass Disconnect : Turns on Yellow on Disconnect Normal: Off LEDs location: LEDs are located on the PCB, visible via holes in the metal bracket holder Connector: (4) LC *Theoretical Distance Defined as half a distance as stated by the IEEE standard 17

18 Install an option card into Slot 1 or 2 The S500 Series expansion slots 1 and 2 supports low-profile cards which can be accessed without the removal of the PCIe expansion module. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Symantec does not assume responsibility or liability for damage resulting from ESD. 1. Unplug the appliance power cords. 2. Open the appliance center cover. 3. Remove the appliance rear cover panel. 4. Unlock the PCIe support latch. 5. Remove the PCIe slot cover by lifting straight up from the appliance. 6. Insert the option card by holding the edges of the card and gently inserting into the slot. It might be necessary to lightly rock the option card into position. Verify that the PCIe card has been fully seated and is aligned with the chassis. 18

19 7. Lock the securing latch. Verify that it is fully closed and that the option card is secured. 8. Reinstall the appliance s center and rear panels. 9. Reconnect the network cabling as necessary for your deployment. 10. Reconnect the power cords. 11. Verify that you have correctly installed the option card. 19

20 Install an option card into Slot 3 or 4 The S500 Series is equipped with a PCIe expansion module that houses four PCIe cards - two full-height and two low-profile cards. Slots 3 and 4 are the only available slots which can accept a full-length card. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Symantec does not assume responsibility or liability for damage resulting from ESD. 1. Unplug the appliance power cords. 2. Open the appliance center cover. 3. Remove the appliance rear cover panel. 4. Remove the PCIe expansion module and flip over the to access the slots. 5. Unlock the blue PCIe support latches. 6. Remove the expansion slot cover by pressing the release button and then pulling out the cover from the side. Set the expansion slot cover aside in a safe location for future use 20

21 7. Insert the option card by holding the edges of the card and gently inserting into the slot. It might be necessary to lightly rock the option card into position. Verify that the PCIe card notch mates with the raised tab on the chassis and secure into place. 21

22 8. Lock the securing latches. Verify that it is fully closed and that the option card is secured. 22

23 9. Reinstall the PCIe expansion module into the chassis. 10. Reinstall the appliance s center and rear panels. 11. Reconnect the network cabling as necessary for your deployment. 12. Reconnect the power cords. 13. Verify that you have correctly installed the option card. 23

24 Install an option card into Slot 5 or 6 The S500 Series is equipped with a PCIe expansion module that houses four PCIe cards - two full-height and two low-profile cards. Slots can only accept low-profile cards. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Symantec does not assume responsibility or liability for damage resulting from ESD. 1. Unplug the appliance power cords. 2. Open the appliance center cover. 3. Remove the appliance rear cover panel. 4. Remove the PCIe expansion module and flip over the to access the slots. 5. Unlock the blue PCIe support latches. 6. Remove the expansion slot cover by pressing the release button and then pulling out the cover from the side. Set the expansion slot cover aside in a safe location for future use 24

25 7. Insert the option card by holding the edges of the card and gently inserting into the slot. It might be necessary to lightly rock the option card into position. Verify that the PCIe card notch mates with the raised tab on the chassis and secure into place. 8. Lock the securing latches. Verify that it is fully closed and that the option card is secured. 25

26 9. Reinstall the PCIe expansion module into the chassis. 10. Reinstall the appliance s center and rear panels. 11. Reconnect the network cabling as necessary for your deployment. 12. Reconnect the power cords. 13. Verify that you have correctly installed the option card. 26

27 Install an option card into Slot 7 The S500 Series is equipped with a PCIe expansion module that houses four PCIe cards - two full-height and two low-profile cards. The S500 Series also come with three low-profile expansion slots directly on the motherboard. These slots can be accessed without the removal of the PCIe expansion module. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Blue Coat does not assume responsibility or liability for damage resulting from ESD. 1. Unplug the appliance power cords. 2. Open the appliance center cover. 3. Remove the appliance rear cover panel. 4. Unlock the PCIe support latch. 5. Remove the PCIe slot cover by lifting straight up from the appliance. 6. Insert the option card by holding the edges of the card and gently inserting into the slot. It might be necessary to lightly rock the option card into position. Verify that the PCIe card has been fully seated and is aligned with the chassis. 7. Lock the securing latch. Verify that it is fully closed and that the option card is secured. 27

28 8. Reinstall the appliance s center and rear panels. 9. Reconnect the network cabling as necessary for your deployment. 10. Reconnect the power cords. 11. Verify that you have correctly installed the option card. 28

29 Open the S500 Series Center Cover The S500 Series center cover protects and houses the system fan units and provides further access to the appliance components. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Blue Coat does not assume responsibility or liability for damage resulting from ESD. 1. Remove or extend the appliance out of the rack to provide ample room for system access. 2. Simultaneously pull the locking tabs on both sides of the chassis towards the front and flip the cover over. Let the cover rest on top of the chassis. 29

30 Remove the S500 Series Rear Cover The S500 Series rear cover protects and provides access to the primary system components, such as the DIMMs, CPUs, option cards, etc. You must remove this panel to access the option cards as well as the SSD image storage devices. You cannot remove the rear cover without first opening the center cover. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Blue Coat does not assume responsibility or liability for damage resulting from ESD. 1. Unlock the rear cover by lifting the latch. 2. Push the rear cover towards the rear of the appliance then lift to remove the cover. Set the rear cover aside at a safe location. 30

31 Remove the S500 Series PCIe Expansion Module The S500 Series is equipped with a PCIe expansion module that houses four PCIe cards - two full-height and two low-profile cards. The S500 Series also comes with three low-profile expansion slots directly on the motherboard. These slots can be accessed without the removal of the PCIe expansion module. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the appliance chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit. Blue Coat does not assume responsibility or liability for damage resulting from ESD. 1. Pull the release latch to unlock the module then lift the handle to unseat the module. 2. Lift the PCIe expansion module by the handle pull straight up and remove from the appliance. 31

32 Install the S500 Series PCIe Expansion Module The S500 Series is equipped with a PCIe expansion module that houses four PCIe cards - two full-height and two low-profile cards. The S500 Series also come with three low-profile expansion slots directly on the motherboard. These slots can be accessed without the removal of the PCIe expansion module. ALWAYS observe proper electrostatic discharge (ESD) conventions. Attach an ESD protective wrist strap to your wrist and to the chassis. Ensure that the appliance is on an ESD-safe work surface or ground the unit appropriately. Blue Coat does not assume responsibility or liability for damage resulting from ESD. 1. Align the PCIe expansion module with the posts on the chassis and press down. The module handle automatically lowers as it is being seated into place. 2. Lock the PCIe module in place by pressing down on the handle the rest of the way while pressing on the four corners of the module. Verify that the module is flat and aligned with the rest of the adjoining chassis structures. 32

Symantec S500 Network Interface Card Options and Installation

Symantec S500 Network Interface Card Options and Installation Symantec S500 Network Interface Card Options and Installation Guide Revision: 5/19/2017 Symantec S500 Network Interface Card Options and Installation 2 Legal Notice Copyright 2017 Symantec Corp. All rights

More information

SG-S to -30 Upgrade Kit. Product Installation Guide

SG-S to -30 Upgrade Kit. Product Installation Guide SG-S400-20 to -30 Upgrade Kit Product Installation Guide Legal Notice Copyright 2017 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo

More information

PE310G4BPI9 Bypass Card Quad Port Fiber 10 Gigabit Ethernet Bypass Server Adapter Intel 82599ES Based

PE310G4BPI9 Bypass Card Quad Port Fiber 10 Gigabit Ethernet Bypass Server Adapter Intel 82599ES Based PE310G4BPI9 Bypass Card Quad Port Fiber 10 Gigabit Ethernet Bypass Server Adapter Intel 82599ES Based Product Description Silicom s quad port fiber 10Gigabit Ethernet Bypass server adapter is a PCI-Express

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Blue Coat ProxySG Maintenance and Upgrade Guide. ProxySG 900 Series B E T A D R A. Document Number: Rev B.2

Blue Coat ProxySG Maintenance and Upgrade Guide. ProxySG 900 Series B E T A D R A. Document Number: Rev B.2 Blue Coat ProxySG Maintenance and Upgrade Guide ProxySG 900 Series B E T A D R A Document Number: 231-03166 Rev B.2 Disclaimer THIS DOCUMENT IS PROVIDED AS IS WITHOUT ANY EXPRESS OR IMPLIED WARRANTY OF

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

PE310G4BPI40-T Bypass Adapter Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel x540 Based

PE310G4BPI40-T Bypass Adapter Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel x540 Based PE310G4BPI40-T Bypass Adapter Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel x540 Based Product Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is

More information

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE Intel NUC Kit DC53427HYE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

PE2G6BPi35 Six Port Copper Gigabit Ethernet PCI Express Bypass Server Adapter Intel based

PE2G6BPi35 Six Port Copper Gigabit Ethernet PCI Express Bypass Server Adapter Intel based PE2G6BPi35 Six Port Copper Gigabit Ethernet PCI Express Bypass Server Adapter Intel based Description Silicom s Six Port Copper Gigabit Ethernet PCI Express Bypass Server adapter is PCI-Express X8 network

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

XTM 1050 Replacement Parts Installation

XTM 1050 Replacement Parts Installation XTM 1050 Replacement Parts Installation Instructions to replace or install: Power Supply Chassis Fan Fiber Card 10 Gb Interface Module WARNING! Do not open the XTM 1050 or try to replace or install any

More information

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C Stonesoft Next Generation Firewall Hardware Guide Models 5201, 5205, 5206 Revision C Table of contents 1 Appliance features...3 Model 5201, 5205, and 5206 features... 3 Interface modules...6 2 Precautions...

More information

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

Stonesoft Next Generation Firewall. Hardware Guide Models 3201, 3202, 3205, 3206, 3207, 3301, Revision F

Stonesoft Next Generation Firewall. Hardware Guide Models 3201, 3202, 3205, 3206, 3207, 3301, Revision F Stonesoft Next Generation Firewall Hardware Guide Models 3201, 3202, 3205, 3206, 3207, 3301, 3305 Revision F Table of contents 1 Appliance features... 3 Model 3201 and 3205 features... 3 Model 3202, 3206,

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Model 6205 Revision A Contents Introduction on page 2 Find product documentation on page 2 Model 6205 features on page 3 Supported interface modules on page 6 Precautions

More information

PIX 520. PIX 520 Product Overview CHAPTER

PIX 520. PIX 520 Product Overview CHAPTER CHAPTER 5 PIX 520 This chapter guides you through the installation of the PIX 520, and includes the following sections: PIX 520 Product Overview, page 5-1 Installing the PIX 520, page 5-4 PIX 520 Feature

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Model 6205 Revision C Contents Introduction on page 2 Find product documentation on page 2 Model 6205 features on page 3 Supported interface modules on page 6 Precautions

More information

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume

More information

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x Last Updated: December 4, 2014 Use these instructions to replace the RAID battery backup unit (BBU)

More information

User s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems

User s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems User s Guide for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems Important GPU Card Compatibility and Installation Information For users installing a GPU

More information

PE310G4TSF4I71 Quad Port SFP+ 10 Gigabit Ethernet PCI Express Time Stamp Server Adapter Intel Based

PE310G4TSF4I71 Quad Port SFP+ 10 Gigabit Ethernet PCI Express Time Stamp Server Adapter Intel Based PE310G4TSF4I71 Quad Port SFP+ 10 Gigabit Ethernet PCI Express Time Stamp Server Adapter Intel Based Product Description Silicom s 40 Gigabit Ethernet PCI Express Time Stamping server adapter is designed

More information

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL User Guide 1 Before You Begin CAUTIONS The procedures in this guide assume familiarity with the general terminology associated with personal

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Models 110, 115 Revision A Contents Introduction on page 2 Find product documentation on page 2 Model N110 features on page 3 Model N115 features on page 5 Precautions

More information

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i7BNHX1 with Intel Optane Memory User Guide 1 Before You Begin CAUTIONS The procedures

More information

Port Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline

Port Type Link Status (Left Side LED) Speed (Right Side LED) Green solid: Link detected/no activity Off: No link/card offline C-Series FlexMedia Card: 36 Ports 10/100/1000 Base-T Ethernet (PoE and non-poe), 8 Ports 1G, 2 Ports 10G Feature Highlights and Installation Instructions Feature Highlights There are two versions of the

More information

Installation Notes for the Catalyst 3750-X and 3560-X Network Modules

Installation Notes for the Catalyst 3750-X and 3560-X Network Modules Installation Notes for the Catalyst 3750-X and 3560-X Network Modules Published: October, 2011 This note provides the installation instructions for the Catalyst 3750-X and 3560-X network modules. Translations

More information

Installation Notes for the Cisco TwinGig and OneX Converter Modules

Installation Notes for the Cisco TwinGig and OneX Converter Modules Installation Notes for the Cisco TwinGig and OneX Converter Modules PID: CVR-X2-SFP and CVR-X2-SFP10G This note provides the installation instructions for the Cisco TwinGig and OneX Converter Modules.

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Models 1101, 1105, 2101, 2105 Revision D Contents Introduction on page 2 Find product documentation on page 2 Series 1100 features on page 3 Series 2100 features

More information

Replacement Instructions

Replacement Instructions apple PowerBook G4 Memory Replacement Instructions Be sure to follow the instructions in this sheet carefully. Failure to follow these instructions could result in damage to your equipment and may void

More information

Replacement Instructions

Replacement Instructions apple Xserve Memory Replacement Instructions Follow the instructions in this sheet carefully. Failure to follow these instructions could damage your equipment and void its warranty. Note: Online instructions

More information

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

PIX 515/515E. PIX 515/515E Product Overview CHAPTER CHAPTER 4 PIX 515/515E This chapter describes how to install the PIX 515/515E, and includes the following sections: PIX 515/515E Product Overview Installing a PIX 515/515E PIX 515/515E Feature Licenses

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Models 1101, 1105, 2101, 2105 Revision E Contents Introduction on page 2 Find product documentation on page 2 Series 1100 features on page 3 Series 2100 features

More information

PE310G4DBi9 Quad port Fiber 10 Gigabit Ethernet PCI Express Content Director Server Adapter Intel based

PE310G4DBi9 Quad port Fiber 10 Gigabit Ethernet PCI Express Content Director Server Adapter Intel based PE310G4DBi9 Quad port Fiber 10 Gigabit Ethernet PCI Express Content Director Server Adapter Intel based Description Silicom s 10 Gigabit Ethernet PCI Express content aware director Bypass server adapters

More information

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices

More information

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1 Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1 User Guide Before You Begin CAUTIONS The procedures in this

More information

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation HP xw8600 and xw9400 Workstations This document describes how to install an Nvidia Quadro FX 5600 graphics card and an

More information

Dual Port Fiber 100 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based

Dual Port Fiber 100 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based PE3100G2DBiR Dual Port Fiber 100 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based Product Description Silicom s 100 Gigabit Ethernet PCI Express content aware director

More information

Dell Inspiron XPS and Inspiron 9100 Service Manual

Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Before You Begin Memory Module, Mini PCI Card, and Devices System Components Subwoofer Bluetooth Card

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

Memory (RAM) Replacement Instructions. apple PowerBook (FireWire) Tools Required. Electrostatic Discharge (ESD)

Memory (RAM) Replacement Instructions. apple PowerBook (FireWire) Tools Required. Electrostatic Discharge (ESD) apple PowerBook (FireWire) Memory (RAM) Replacement Instructions Be sure to follow these instructions carefully. Failure to follow these instructions could result in damage to your equipment and may void

More information

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com. Please check out our ebay auctions for more great deals on Factory Service Manuals: servicemanuals4u Dell Latitude

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Replacing the Gateway M305 Optical Drive

Replacing the Gateway M305 Optical Drive Replacing the Gateway M305 Optical Drive This package includes an optical drive, such as a CD or DVD drive, for your Gateway M305 notebook and these printed instructions. Installing a replacement drive

More information

PE340G2DBIR Dual Port Fiber 40 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based

PE340G2DBIR Dual Port Fiber 40 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based PE340G2DBIR Dual Port Fiber 40 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based Product Description Silicom s 40 Gigabit Ethernet PCI Express content aware director

More information

I/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements

I/O Modules Overview. Before You Begin. I/O Module Options. ESD Requirements I/O Modules Overview Use these instructions to set up the I/O modules supported in your TippingPoint security devices. Before You Begin Review the release notes for your product for any late-breaking changes

More information

Dell XPS 14z Owner s Manual

Dell XPS 14z Owner s Manual Dell XPS 14z Owner s Manual Computer model: L412z Regulatory model: P24G series Regulatory type: P24G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services 03-603448 Issue 1 November 2009 2011 Avaya Inc. All Rights Reserved. is 1-800-242-2121 in the United States. For additional support

More information

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ User Guide 1 Before You Begin CAUTION The procedures in this guide assume familiarity with

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNHXG User Guide 1 Before You Begin

More information

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices

More information

Dell Inspiron N5110 Service Manual

Dell Inspiron N5110 Service Manual Dell Inspiron N5110 Service Manual Regulatory model: P17F Regulatory type: P17F001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers) Instructions (For 6180 Industrial Computers) This document describes how to remove or install a Pentium processor in the 6180 Industrial Computer. Processor specifications are also provided. The processor

More information

120Ra-1 Pentium III Processor Installation Insert

120Ra-1 Pentium III Processor Installation Insert 120Ra-1 Pentium III Processor Installation Insert PN: 455-01614-000 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Replacing the Battery HP t5730 and t5735 Thin Clients

Replacing the Battery HP t5730 and t5735 Thin Clients Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide Quick Start Guide Upgrade kit contents The table below shows the contents of the V5420 Host Card Upgrade Kit (components are not shown to scale). Part Function Pieces V5420 Host Card 1 Host card bracket

More information

Table of Contents - 1. Predator PO3-600 User s Guide

Table of Contents - 1. Predator PO3-600 User s Guide Table of Contents - 1 Predator PO3-600 User s Guide 2 - Upgrading your Computer 2018. All Rights Reserved. Desktop Computer Covers: Tower models This revision: April 2018 V1.00 Important This manual contains

More information

PE210G2SPi9A Dual Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel based. Description. Key Features

PE210G2SPi9A Dual Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel based. Description. Key Features PE210G2SPi9A Dual Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel based Description Silicom s SFP+ 10 Gigabit Ethernet PCI Express server adapters are designed for Servers and high-end

More information

PE310G4SPI9LA Quad Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel 82599ES Based

PE310G4SPI9LA Quad Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel 82599ES Based PE310G4SPI9LA Quad Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel 82599ES Based Product Description Silicom s 10 Gigabit Ethernet PCI Express server adapters are designed for Servers and

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

742S 742i SC742 CHASSIS USER'S GUIDE

742S 742i SC742 CHASSIS USER'S GUIDE 742S 742i SC742 CHASSIS USER'S GUIDE 1.0a SC742 Chassis User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

User Guide. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA. Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA

User Guide. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA. Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar

More information

PE2G4SFPI35L Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel i350am4 Based

PE2G4SFPI35L Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel i350am4 Based PE2G4SFPI35L Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel i350am4 Based Product Description Silicom s Quad Port SFP Gigabit Ethernet PCI Express Server adapter is PCI-Express X4 SFP

More information

Installing and Upgrading Memory and Virtual Private Network Modules

Installing and Upgrading Memory and Virtual Private Network Modules APPENDIX C Installing and Upgrading Memory and Virtual Private Network Modules This chapter tells how to install or upgrade memory and how to install a Virtual Private Network (VPN) module in your Cisco

More information

Replacing the Gateway M275 Keyboard

Replacing the Gateway M275 Keyboard Replacing the Gateway M275 Keyboard This package includes a replacement keyboard for your Gateway M275 notebook and these printed instructions. Tools you need You need a small Phillips screwdriver and

More information

Dell OptiPlex All-in-One. Stand Installation Guide

Dell OptiPlex All-in-One. Stand Installation Guide Dell OptiPlex All-in-One Stand Installation Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Replacing the Gateway 200ARC Keyboard

Replacing the Gateway 200ARC Keyboard Replacing the Gateway 200ARC Keyboard Replacing the Gateway 200ARC Keyboard This package includes a replacement keyboard for your Gateway 200ARC notebook and these printed instructions. Tools you need

More information

QUICK START GUIDE 7000 SERIES DEVICES

QUICK START GUIDE 7000 SERIES DEVICES QUICK START GUIDE 7000 SERIES DEVICES Thank you for choosing Sourcefire! Before installing this device, download and follow the instructions in the Sourcefire Support Welcome Kit (https://support.sourcefire.com)

More information

User s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems. For Windows

User s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems. For Windows User s Guide for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems For Windows Contents 1 Introduction, Compatibility Information, and Setup Overview 1 Introduction

More information

PE340G2BPI71 Dual Port Fiber 40 Gigabit Ethernet PCI Express Bypass Server Adapter Intel XL710 Based

PE340G2BPI71 Dual Port Fiber 40 Gigabit Ethernet PCI Express Bypass Server Adapter Intel XL710 Based PE340G2BPI71 Dual Port Fiber 40 Gigabit Ethernet PCI Express Bypass Server Adapter Intel XL710 Based Product Description Silicom s 40 Gigabit Ethernet PCI Express Bypass server adapters are designed for

More information

H4 Series Hardware Replacement Guide

H4 Series Hardware Replacement Guide Machine type: 10059/7723 10060/7724 10068/7752 10080/3099/1194 10091/2558/1196 H4 Series Hardware Replacement Guide Version 3.0 2011.08 31500379 Hardware Replacement Guide Copyright Lenovo 2011. All rights

More information

Wall-Mounting your HP TouchSmart. User Guide

Wall-Mounting your HP TouchSmart. User Guide Wall-Mounting your HP TouchSmart User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Replacing the Gateway M405 Keyboard

Replacing the Gateway M405 Keyboard Replacing the Gateway M405 Keyboard This package includes a replacement keyboard for your Gateway M405 notebook and these printed instructions. Tools you need You need a small Phillips and a small flat-blade

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Blue Coat ProxySG First Steps Transparent Proxy Deployments SGOS 6.7

Blue Coat ProxySG First Steps Transparent Proxy Deployments SGOS 6.7 Transparent Proxy Deployments SGOS 6.7 Legal Notice Copyright 2018 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo are trademarks

More information

PE2G4B19L Quad Port Copper Gigabit Ethernet PCI Express Server Adapter Broadcom BCM5719 Based

PE2G4B19L Quad Port Copper Gigabit Ethernet PCI Express Server Adapter Broadcom BCM5719 Based PE2G4B19L Quad Port Copper Gigabit Ethernet PCI Express Server Adapter Broadcom BCM5719 Based Product Description Silicom s Quad Port Copper Gigabit Ethernet PCI Express Server adapter is PCI-Express X4

More information

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNHXG User Guide 1 Before You Begin

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell SCv3000 and SCv3020 Storage System Owner s Manual Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Hard Drive user manual

Hard Drive user manual Hard Drive Docking Kit user manual Model 450096 MAN-450096-UM-1007-02 introduction Thank you for purchasing the MANHATTAN Hard Drive Docking Kit, Model 450096. The easy-to-follow instructions in this user

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

Installing a Network Module

Installing a Network Module 3 CHAPTER This chapter describes how to install and connect a network module. Overview, page 3-1 in the Switch, page 3-4 SFP and SFP+ Modules, page 3-7 Finding the Network Module Serial Number, page 3-9

More information

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ User Guide 1 Before You Begin CAUTION The steps in this guide assume you re familiar

More information