Contents. A Trap List Overview B Trap List A.1 Notes... 3 A.2 How to read the trap list... 3 A.3 Screen display examples...

Size: px
Start display at page:

Download "Contents. A Trap List Overview B Trap List A.1 Notes... 3 A.2 How to read the trap list... 3 A.3 Screen display examples..."

Transcription

1 ServerView Trap List About this manual A Trap List Overview This describes how to read the trap list table and the screen display examples. B Trap List The trap list is described according to its various classifications. Trademarks Microsoft, Windows, MS, Windows Server are registered trademarks of the Microsoft Corporation in the USA and other countries. Intel and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the USA and other countries. All other hardware and software names used are trademarks or registered trademarks of their respective manufacturers. Other product names are copyrights of their respective manufacturers. All Rights Reserved, Copyright FUJITSU LIMITED

2 Contents A Trap List Overview A.1 Notes A.2 How to read the trap list A.3 Screen display examples B Trap List B.1 SNI-TRAP-MIB (trap.mib) B.2 SNI-SERVER-CONTROL-MIB (sc.mib) B.3 SNI-SERVERVIEW-MIB (serverview.mib) B.4 SNI-HD-MIB (hd.mib ) B.5 SERVERVIEW-STATUS-MIB (status.mib) B.6 FSC-SERVERCONTROL2-MIB (sc2.mib) B.7 FSC-THRESHOLD-REPORT-MIB (Threshold.mib) B.8 FSC-RAID-MIB (raid.mib) B.9 SIEMENS-MULTIPATH-MIB (mp.mib) B.10 SERVERVIEW-DUPLEXDATAMANAGER-MIB (ddm.mib) B.11 SNI-MYLEX-MIB (mylex.mib) B.12 BLADE-MIB (S31.mib) B.13 AdaptecArrayController-MIB (aac.mib) B.14 IOMMIB (iommib.mib) B.15 DPT-SCSI-MIB (dptscsi.mib) B.16 MYLEXRAID-MIB (Mlxraid.mib) B.17 MYLEXRAID-FJ-MIB (Mlxraidfj.mib) B.18 FASTTRAK-MIB (promisev1.mib) B.19 PROMISE-UNIFIED-MIB (promiseraid.mib) B.20 SW-MIB (fcswitch.mib) B.21 INTEL-WFM-MIB (WFM.mib ) B.22 UPSMAN (Upsman.mib) B.23 UPS-MIB (RFC1628.mib) B.24 PowerNet-MIB (powernet.mib) B.25 ROMPILOT-MIB (ROMPILOT.MIB) B.26 RFC1157 (rfc1157.mib) B.27 NET-SNMP-MIB (net-snmp.mib) B.28 FUJITSU-SERVERVISOR-MIB (Servervi.mib) B.29 Alert-Definition-Originator-MIB (F5emt2o.mib) B.30 LDSM-MIB (ldsm.mib) B.31 LDCM-MIB (Ldcm.mib) B.32 ADAPTECDURALINK-MIB (duralink.mib)

3 A.1 Notes A Trap List Overview This manual shows an overview of SNMP traps viewable in the ServerView alarm service and explains how to read the trap lists in this manual. A.1 Notes In this manual, traps shown as "Not supported" or traps not listed are unsupported. (Including traps not shown as UNKNOWN and traps shown in the class "4" and "5" alarm list in "A.2 How to read the trap list" ( pg.3)). Because the Agents of I/O component traps vary, they are supplied by the various vendors. Depending on the version of the Agents, message content may change. Refer to the manual provided with the server for details about messages. When "ENTERPRISE OID" is a version other than "enterprises.231" the contact representative will vary depending on the vendor it is supplied by. A.2 How to read the trap list The displayed content of trap messages is classed in the following way. 1. Pop up messages 2. OS event logs 3. AlarmService alarm list 4. Alarm list of the AlarmService alarm settings 5. MIB file Help alarm list alarm type The trap list entries are displayed in the following way. Table: Explanation of the trap list content (%d: optional number : system [Upper side]*1 *3 *4 *5 *6 [Lower side]*2 *1 : Name of the trap. Corresponding to "5. MIB file Help alarm list alarm type". *2 : Name of the trap. Corresponding to "3. AlarmService alarm list" and "4. Alarm list of the AlarmService alarm settings". *3 : List number of the trap. 3

4 A Trap List Overview *4 : (error class) of the trap. Importance level Importance level when log is done by OS Interpretation concerning displayed by the trap list Windows Linux Importance level INFOMAT Information information Notification of information MINOR Warning warning Warning MAJOR Error error message Error CRITICAL Error critical message Error *5 : The content displayed by "1. Pop up messages" and "2. OS event logs" is described. In the log stored by AlarmService, the following messages are added to the head of a detailed message. ServerView received the following alarm from server [Model name of server]:detailed message Example of displaying syslog in Linux: FSC ServerView Services[6964]:(critical message) ServerView received the following alarm from server TX150S5: Fan 'FAN PSU' failed in cabinet 0 of server 'TX150S5' 5 1: Decided message (= FSC ServerView Services) It is shown that AlarmService outputs the logs. 2: Importance level 3: Decided message (= ServerView received the following alarm from server) It is shown to have received the message from the alarm sending origin. 4: Host name of alarm sending origin 5: Detailed message *6 : Detailed explanation to the trap or an explanation of the action method to the trap. A.3 Screen display examples The screen display examples are as follows: Popup 4

5 A.3 Screen display examples OS Event log / Syslog For Windows The source is an event log of "Fujitsu ServerView Services". The example of the event log is shown as follows. For Linux The syslog begins with "FSC ServerView Services". The example of the syslog is shown as follows. FSC ServerView Services[6964]: (critical message) ServerView received the following alarm from server TX150S5: Fan 'FAN PSU' failed in cabinet 0 of server 'TX150S5'. AlarmService (Alarm Monitor) alarm list 5

6 A Trap List Overview Alarm list of the AlarmService alarm settings MIB file Help alarm list In order to use this display the above screens, you must perform the following operations: 1. Start the ServerView AlarmService. 2. Click AlarmService [Help]. 3. Click [Agent alarm information] in the [Contents]. 4. Click [RFC1157.mib] in "AlarmMib". 6

7 A.3 Screen display examples Description examples that appear in the mib file. Description examples that appear in the mib file are shown below. testtrap TRAP-TYPE ENTERPRISE sniservermgmt VARIABLES { trapservername, traptime } DESCRIPTION "Test trap to verify trap connection." --#TYPE "Test trap" --#SUMMARY "Test trap from server (no error)." --#ARGUMENTS { 0 } --#SEVERITY INFORMAT --#TIMEINDEX 1 --#HELP "Note: This is no error condition." --#HELPTAG --#STATE OPERAT ::= 600 7

8 B Trap List B Trap List B.1 SNI-TRAP-MIB (trap.mib) Traps from the ServerView console. sninwvolsysmounted Volume SYS is mounted sninwsysvolumedismounted Volume SYS is dismounted sninwvolumemounted Volume is mounted sninwvolumedismounted Volume is dismounted sninwdownserver Server is going down (NetWare) sninwexittodos Server exits to DOS sninwmoduleunloaded Module is unloaded sninwclearconnection Connection is cleared sninwloginuser User logged into server sninwcreatebinderyobj Bindery object created sninwdeletebinderyobj Bindery object deleted sninwchangesecurity Security changed (NetWare) sninwactivatescreen Screen activated sninwupdatescreen Screen updated sninwupdatecursor Cursor position updated sninwkeywaspressed Key pressed sninwdeactivatescreen Screen deactivated sninwtrusteechange Trustee changed (NetWare) sninwopenscreen Screen opened Table: SNI-TRAP-MIB Trap (ENTERPRISE : enterprises.231) 0 INFORMAT (%d: optional number : system Volume SYS is mounted on server 1 CRITICAL Volume SYS is dismounted on server 2 INFORMAT 3 INFORMAT Volume is mounted on server Volume is dismounted on server 4 CRITICAL Server is going down: 7 CRITICAL Server exits to DOS : 8 INFORMAT 9 INFORMAT 10 INFORMAT 11 INFORMAT 12 INFORMAT 13 INFORMAT 14 INFORMAT 15 INFORMAT 16 INFORMAT 17 INFORMAT 18 INFORMAT 19 INFORMAT 20 INFORMAT Module is unloaded on server A connection is cleared on server A user logged into server A bindery object is created on server A bindery object is deleted on server Security change has occurred on server A screen is activated on server A screen is updated on server The cursor position is updated on server A key is pressed on server A screen is deactivated on server Trustee is changed on server A Screen is opened on server A Netware monitor Trap. Not supported. 8

9 B.1 SNI-TRAP-MIB (trap.mib) sninwclosescreen Screen closed sninwmodifydirentry Directory entry changed sninwnorelinquishcontrol NLM has not relinquished control sninwthreadswitch Thread switch has occurred sninwmoduleloaded Module loaded sninwcreateprocess Process created sninwdestroyprocess Process destroyed Table: SNI-TRAP-MIB Trap (ENTERPRISE : enterprises.231) 21 INFORMAT 22 INFORMAT A Screen is closed on server Directory entry is changed on server 23 CRITICAL The NLM has not relinquished control on server 25 INFORMAT 27 INFORMAT 28 INFORMAT 29 INFORMAT (%d: optional number : system A thread switch has occurred on server Module is loaded on server A Process is created on server A Process is destroyed on server sninwnewpublic New public symbol 32 INFORMAT A new public symbol is registered on server sninwprotocolbind Protocol bound sninwprotocolunbind Protocol unbound sninwallocateconnection Connection allocated sninwlogoutconnection User logged out sninwmlidregister MLID registered sninwmlidderegister MLID deregistered sninwdatamigration File data migrated sninwdatademigration File data demigrated sninwqueueaction Queue status changed sninwalert Alert written sninwcreateobject DS object created sninwdeleteobject DS object deleted sninwrenameobject DS object renamed sninwvaluechanged DS object value changed sninwclosefile File closed sninwchangetime Time changed (NetWare) 33 INFORMAT A protocol is bound to a MLID on server 34 MAJOR A protocol is unbound from a MLID on server 37 INFORMAT 38 INFORMAT 39 INFORMAT 40 INFORMAT 41 INFORMAT 42 INFORMAT 43 INFORMAT 44 INFORMAT 46 INFORMAT 47 INFORMAT 48 INFORMAT 49 INFORMAT 50 INFORMAT 51 INFORMAT A connection is allocated on server A user has logged out of server A MLID is registered on server A MLID is deregistered on server A files data has been migrated on server A files data has been demigrated on server A queue is activated, deactivated, created or deleted on server A Netware Alert message is written to the console on server. Module : A Directory Service object is created on server A Directory Service object is deleted on server A Directory Service object is renamed on server A Directory Service object's value changed on server A file is closed on server Time has changed or a nonuniform time adjustment has occurred on server 9

10 B Trap List sniinvpolltrapexceeded Threshold exceeded sniinvpolltrapunderflow Threshold underflow sniinvpolldeltaexceeded DELTA-Threshold exceeded sniinvdeltatrapunderflow DELTA-Threshold underflow sniinvtrapinvalid Threshold invalid sniinvtrapvalid Threshold valid snintdownserver Server is going down (NT) snintloginuser User logged in snintchangesecurity Security changed (NT) sninttrusteechange Trustee changed (NT) snintalert NT Alert written snintchangetime Time changed (NT) snintregchangename Keyname changed snintregchangeattr Registry key attributes changed snintregchangelastwrite Registry last write time changed snintregchangesecurity Registry key security changed snintfilechangename File name modified snintfilechangedirname Directory name modified snintfilechangeattr File attributes changed snintfilechangesize File size changed snintfilechangelastwrite File last write time changed snintfilechangesecurity File security changed Table: SNI-TRAP-MIB Trap (ENTERPRISE : enterprises.231) 128 INFORMAT 129 INFORMAT 130 INFORMAT 131 INFORMAT 132 INFORMAT 133 INFORMAT 300 INFORMAT 301 INFORMAT 302 INFORMAT 303 INFORMAT 304 INFORMAT 305 INFORMAT 310 INFORMAT 311 INFORMAT 312 INFORMAT 313 INFORMAT 320 INFORMAT 321 INFORMAT 322 INFORMAT 323 INFORMAT 324 INFORMAT 325 INFORMAT (%d: optional number : system Threshold exceeded :, on Server Threshold underflow :, on Server DELTA-Threshold exceeded :, on Server DELTA-Threshold underflow :, on Server Threshold Invalid:, on Server Threshold Valid:, on Server Server is going down : A user logged into server Security change has occurred on server A trustee is changed on server An NT Alert message is written to the eventlog (Control String: ) on server. Time has changed or a nonuniform time adjustment has occurred on server Keyname in registry has been changed on server Attributes for a key or its subtree in registry has been changed on server Last write time for a key or its subtree in registry has been changed on server Security for a key or its subtree in registry has been changed on server A file name has been changed, created or deleted on server A directory name has been changed, created or deleted on server File or directory attributes have been changed on server File size has been changed on server Last write time on a file has been changed on server Security on a file has been changed on server This message shows that the threshold exceeded the value set in the threshold manager. This message refers to the value set in the threshold manager. 10

11 B.2 SNI-SERVER-CONTROL-MIB (sc.mib) sninteventlogerror Eventlog entry: error sninteventlogwarning Eventlog entry: warning sninteventloginformation Eventlog entry: information sninteventlogsuccess Eventlog entry: success audit sninteventlogfailure Eventlog entry: failure audit Table: SNI-TRAP-MIB Trap (ENTERPRISE : enterprises.231) 330 INFORMAT 331 INFORMAT 332 INFORMAT 333 INFORMAT 334 INFORMAT (%d: optional number : system Error entry written to eventlog on server Warning entry written to eventlog on server Warning entry written to eventlog on server Informational entry written to eventlog on server Audit success entry written to eventlog on server Failure audit entry written to eventlog on server B.2 SNI-SERVER-CONTROL-MIB (sc.mib) Traps from the ServerView agent or RSB. testtrap Test trap fanerror Fan failed tempok Temperature normal tempwarn Temperature warning tempcritical Temperature critical traponbattery AC failed, on battery Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 600 INFORMAT (%d: optional number : system Test trap from server (no error). 601 CRITICAL Fan %d failed in cabinet %d of server. 602 INFORMAT Temperature at sensor %d in cabinet %d of server is within normal range. 603 MAJOR Temperature at sensor %d in cabinet %d of server has reached the warning level. 604 CRITICAL Temperature at sensor %d in cabinet %d of server has reached the critical level. 606 CRITICAL AC failure. Cabinet %d is running on battery power since %d seconds. In %d minutes server will shutdown. No error. A fan error occurred. Contact an office listed in the "Contact The internal temperature of the server is within the normal range. No error. A device temperature error occurred. Check the room temperature. If room temperature is normal check whether the fan has failed. Other errors in hardware are possible. Contact an office listed in the "Contact Running on UPS battery power. Check that UPS power cables are not unplugged and there has been no power interruption. 11

12 B Trap List traponmains AC OK selftestwarning Controller selftest warning selftesterror Controller selftest error svcommunicationfailure Communication lost scbunconfiguredupsdetected UPS not configured scbupsnotdetected UPS not detected scbunconfiguredbbudetected BBU not configured scbbbunotdetected BBU not detected notenoughcabinets SE's missing toomanycabinets Too many SE's cabinetswitchedoff Cabinet switched off cabinetswitchedon Cabinet switched on internalerror Internal error servershutdown Server shutdown Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 607 INFORMAT (%d: optional number : system Mains returned after power failure in cabinet %d at server. 608 MINOR The Server Management controller in cabinet %d has detected an minor problem during selftest of server. 609 CRITICAL The Server Management controller in cabinet %d of server failed. 610 MINOR Communication with the Server Management controller in cabinet %d of server lost. 611 INFORMAT UPS detected by server, but no UPS is configured. 612 MAJOR A UPS is configured but no UPS detected by server. 613 INFORMAT 614 INFORMAT BBU detected by server, but no BBU is configured. A BBU is configured but no BBU is detected by server. 615 MAJOR The actual number of storage extensions at server is lower than the configured. 616 MINOR The actual number of storage extensions at server is higher than the configured. 617 INFORMAT 618 INFORMAT 620 INFORMAT 621 INFORMAT Cabinet %d was switched off because of (server ). Cabinet %d was switched on because of (server ). Internal error #%d in server management controller software. (module at server ). The reason causes a shutdown at server. Stopped running on the UPS battery. No problem. If multiple messages are detected, it is possible that the Server Management controller has failed. Contact an office listed in the "Contact If recovered in event ID:10636 there is no problem. If not restored, contact an office listed in the "Contact It is possible that there is an error in the settings. Recheck the settings. If there is no error in the settings it is possible that a UPS error occurred. Contact an office listed in the "Contact There is an error in the configuration of the external memory device. Recheck this. Server has turned off. Server has turned on. This is a software error. Specify the name of the module and contact an office listed in the "Contact Shutdown at the server is performed by ordering shutdown. 12

13 B.2 SNI-SERVER-CONTROL-MIB (sc.mib) fancriticalerror Fan will fail cabinetnotconfigured Cabinet not configured powersupplyremoved Power supply removed powersupplyadded Power supply added powersupplyfailed Power supply failed powersupplyok Power supply OK powersupplystatuscritical Power supply critical fanok Fan OK tempsensorbroken Temperature sensor broken servermanagementdisabled Server management disabled Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 622 MAJOR Fan %d will fail in near future in cabinet %d of server. 623 INFORMAT 624 INFORMAT 625 INFORMAT Cabinet %d at server is not configured. Depending on the system type, run Server Configuration Utility (SCU) or Storage Extension Manager (SEMAN) and configure the cabinet! Power supply %d in cabinet %d at server was removed. Power supply %d in cabinet %d at server was added. 626 MAJOR Power supply %d in cabinet %d at server failed. 627 INFORMAT Power supply %d in cabinet %d at server is working again. 628 CRITICAL Insufficiant operating power supplies available in cabinet %d at server. 629 INFORMAT Fan %d in cabinet %d of server is working again. 630 MAJOR Temperature sensor %d in cabinet %d of server is broken or not connected. 631 INFORMAT (%d: optional number : system Server management BIOS on server is disabled. Enable it to have full server management functionality! This predicts a fan error. A failure will not occur soon. Contact an office listed in the "Contact The cabinet is not correctly configured. Set again. The power supply unit was removed by the operator. The power supply unit was added by the operator. The PSU has failed. Contact an office listed in the "Contact This message appears after the power supply unit has been attached. Install the power supply unit. This message shows that the fan has returned to normal. This message appears when a fan is replaced. Temperature sensor may be faulty. Contact an office listed in the "Contact In order to enable the server management, perform settings using the maintenance tools attached to the hardware. 13

14 B Trap List trapacfail AC failed trapduplicatecabinetid Duplicate cabinet ID trapeventlog Error in event log tempsensorok Temperature sensor OK svcommunicationestablished Communication established correctablememerroraddr Correctable memory error uncorrectablememerroraddr Uncorrectable memory error Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 632 CRITICAL AC failure in cabinet %d of server. This message is stored when performing UPS scheduled operations. There is no problem in this case. When not performing UPS scheduled operations, there is a possibility of a power supply error. Contact an office listed in the "Contact 633 MAJOR Two or more cabinets have the same ID %d on server. 634 MAJOR An error was recorded on server. See server management event / error log (Recovery) for detailed information. 635 INFORMAT 636 INFORMAT 637 INFORMAT (%d: optional number : system Temperature sensor %d in cabinet %d of server is working again. Communication with the Server Management controller in cabinet %d of server established again. Correctable memory error at address %d in cabinet %d of server. 638 CRITICAL Uncorrectable memory error at address %d in cabinet %d of server. There is an error in the system configuration. Set the configuration again. An error occurred during POST. Refer to the information stored in "Action" and "Error buffer" in ServerView. This message appears when the temperature sensor recovers. This message appears when communication with the Server Management controller has recovered. An SBE (memory single bit error) has occurred. There is no effect because of the existence of ECC memory. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact 14

15 B.2 SNI-SERVER-CONTROL-MIB (sc.mib) correctablememerrorbank Correctable memory error #1 uncorrectablememerrorbank Uncorrectable memory error #1 correctablememerrormodule Correctable memory error #2 uncorrectablememerrormodul e Uncorrectable memory error #2 correctablememerror Correctable memory error #3 uncorrectablememerror Uncorrectable memory error #3 powerofftimereached Power off time reached frontdoorstatuschanged Front door status changed Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 639 INFORMAT Correctable memory error at bank %d in cabinet %d of server. 640 CRITICAL Uncorrectable memory error at bank %d in cabinet %d of server. 641 INFORMAT Correctable memory error at module %d in cabinet %d of server. 642 CRITICAL Uncorrectable memory error at module %d in cabinet %d of server. 643 INFORMAT Correctable memory error in cabinet %d of server. 644 CRITICAL Uncorrectable memory error in cabinet %d of server. 645 INFORMAT 646 INFORMAT (%d: optional number : system The power-off time is reached in cabinet %d on server! System shutdown in %d minutes. The front door status of cabinet %d on server has changed. An SBE (memory single bit) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact An SBE (memory single bit error) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact An SBE (memory single bit error) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact Shut down is performed due to an order by the ServerView console or a power off scheduled in ServerView. The door has been opened or closed by the operator. 15

16 B Trap List housingopenstatuschanged Housing open status changed sniscredundantfanfailed Redundant fan failed sniscredundantpowersupply Failed Redundant power supply failed sniscvoltageok Voltage OK sniscvoltagetoolow Voltage too low sniscvoltagetoohigh Voltage too high sniscfanadded Fan added sniscfanremoved Fan removed sniscshutdowncancelled Shutdown cancelled snisccpuspeedchanged CPU speed changed Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 647 INFORMAT The housing open status of cabinet %d on server has changed. 648 MAJOR The redundant fan %d failed in cabinet %d of server. System can become critical if another fan in this group fails. 649 MAJOR Redundant power supply %d in cabinet %d at server failed. System can become critical if another power supply fails. 650 INFORMAT Power supply voltage %d () in cabinet %d at server is within normal range again. 651 CRITICAL Power supply voltage %d () in cabinet %d at server is too low. 652 CRITICAL Power supply voltage %d () in cabinet %d at server is too high. 653 INFORMAT 654 INFORMAT 655 INFORMAT 656 INFORMAT (%d: optional number : system The fan %d was added into cabinet %d of server. The fan %d was removed from cabinet %d of server. Shutdown at server cancelled by the user. CPU speed at server changed to %d percent of its maximum speed. The CPU speed can be changed by the server management because of temperature problems. The cover of the server has been opened or closed by the operator. A redundant fan failure has occurred. Contact an office listed in the "Contact A redundant power supply failure has occurred. Contact an office listed in the "Contact The server voltage has recovered. There is no problem. A problem may have occurred with the power supply unit, AC power supply or the base board etc. Contact an office listed in the "Contact A problem may have occurred with the power supply unit, AC power supply or the base board etc. Contact an office listed in the "Contact The fan was added by the operator. The fan was removed by the operator. This is an operation. The speed of the CPU is lowered because of the high temperature of the CPU. Check CPU temperature. A broken fan may be causing the temperature of the CPU to rise. 16

17 B.2 SNI-SERVER-CONTROL-MIB (sc.mib) siescpoweron Power on siescnobootcpu No boot cpu siescposterror Post error siescsetupentered Setup entered siescbooterror Boot error siescbootwatchdogexpired Boot watchdog expired siescsoftwarewatchdogexpir ed Software watchdog expired siescuserauthenticationfailur e User authentication failure siescdiagnosticboot Diagnostic boot siescbootretrycountzero Boot retry counter zero siescmessagelogfull Message log full memerrormoduleprefailure Memory module prefailure Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) 657 INFORMAT 658 INFORMAT 659 INFORMAT 660 INFORMAT 661 INFORMAT 662 INFORMAT 663 INFORMAT The reason causes a power on at server. System boot of the server failed, because no valid boot cpu available. The reason causes a power on at server. The bios setup is entered at server. No bootable operation system found at server. Boot watchdog of server expired. Software watchdog of server expired. 664 MAJOR User authentication failure detected at server, interface %d, performing protocol. 665 INFORMAT (%d: optional number : system Server is performing a diagnostic boot. 666 MAJOR Boot retry counter is zero on server. On next critical error shutdown the server will no longer try to reboot. System will run diagnostic system or switch off. 667 MINOR The System Event Log on server in cabinet %d is full. No more messages can be logged. Please clear unneeded log entries as soon as possible! 668 MAJOR Memory module failure is predicted for module %d in cabinet %d of server. This message appears when the power supply is turned on. Check the system. A CPU error may have occurred. IF this occurs frequently, contact an office listed in the "Contact Setup operations have been performed by the operator. Check the system. Operations were performed for the amount of retry counters set. Set the retry counters again. Operations were performed for the amount of retry counters set. Set the retry counters again. Check the authentication operations. Diagnostic operations are performed by the operator. Operations were performed for the amount of retry counters set. Set the retry counters again. Clear the unnecessary System Event Log using the maintenance tools attached to the hardware. This predicts a memory error. Contact an office listed in the "Contact 17

18 B Trap List memerrormodulefailing Memory module failing memerrormodulereplaced Memory module replaced sniscpowersupplyredundanc ylost Power supply redundancy lost siescmessagelogwarning Message log warning siesccpuprefailure CPU prefailure siescpowerfail Power failed siescbiosselftesterror Critical BIOS selftest error Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) (%d: optional number : system 669 MAJOR Memory module %d in cabinet %d of server is failing. Too many errors have occured. 670 MAJOR Memory module %d in cabinet %d of server had failed and was replaced by a hot-spare module. 671 MINOR Power supply redundancy in cabinet %d at server lost. System will become critical if a power supply fails. 672 MINOR The System Event Log for cabinet %d at server has exceeded %d%% of its capacity. 673 MAJOR CPU failure is predicted for CPU %d in cabinet %d of server. 674 CRITICAL DC power failure in cabinet %d of server. 675 CRITICAL A critical error happend while BIOS selftest in cabinet %d of server.see server management message log (recovery log) for detailed information. Warning predicting a memory error. Contact an office listed in the "Contact Memory error. Contact an office listed in the "Contact Power supply unit error. Contact an office listed in the "Contact This predicts a System Event Log. Clear the unnecessary System Event Log using the maintenance tools attached to the hardware. Warning predicting a CPU error. Contact an office listed in the "Contact Power supply unit error. Contact an office listed in the "Contact An error has been detected during BIOS selftest. Rrefer to SEL for details and contact an office listed in the "Contact 18

19 B.3 SNI-SERVERVIEW-MIB (serverview.mib) siescbiosselftestwatchdogex pired BIOS selftest watchdog expired sniscvoltagefailure Voltage out of range sniscbatteryvoltageprefailure Battery failure predicted siescseveresystemerror The system was restarted after a severe problem Table: SNI-SERVER-CONTROL-MIB Trap (ENTERPRISE : enterprises ) (%d: optional number : system 676 MAJOR BIOS selftest watchdog of server expired. 677 CRITICAL Power supply voltage %d () in cabinet %d at server is out of range. 678 MAJOR Battery voltage %d () in cabinet %d at server : Battery is predicted to fail in near future. 679 CRITICAL The system was restarted after a severe problem at cabinet %d of server. See server management message log (recovery log) for detailed information. An error has been detected during BIOS selftest. Refer to SEL for details and Contact an office listed in the "Contact Power supply unit error. Contact an office listed in the "Contact This predicts a power supply unit error. Contact an office listed in the "Contact A serious problem has occurred on your system. Contact an office listed in the "Contact B.3 SNI-SERVERVIEW-MIB (serverview.mib) ServerView console traps. snisvgenerictrapforward ServerView alarm received snisvpageroff Pager turn off snisvserverstatechanged Server changed state snisvpassthroughtrapforwar d ServerView alarm passed through siesvalarmservicecommand Alarm Service Command fscsvserveradded Server added Table: SNI-SERVERVIEW-MIB Trap (ENTERPRISE : enterprises ) 700 INFORMAT 701 INFORMAT 702 INFORMAT 703 INFORMAT 704 INFORMAT 705 INFORMAT (%d: optional number : system The server sent the trap <> to ServerView application at station Pager number %d should be turned off. The server has changed its state to Trap sent from the alarm service. Trap sent from the alarm service. Command %d from server. Server was added. 19

20 B Trap List fscsvserverremoved Server removed fscsvserverchanged Server changed fscsvserverstatuschanged Server status changed fscsvgroupadded Group added fscsvgroupremoved Group removed fscsvgroupchanged Group changed fscsvexploreserver Explore server fscastestmail Alarm Service Test Mail fscastestpager Alarm Service Test Pager fscasstoptraplistenservice Alarm Service Stop Trap Listen Service Table: SNI-SERVERVIEW-MIB Trap (ENTERPRISE : enterprises ) (%d: optional number : system Server was removed. 706 INFORMAT 707 INFORMAT 708 INFORMAT 709 INFORMAT 710 INFORMAT 711 INFORMAT 712 INFORMAT 747 INFORMAT 748 INFORMAT 749 INFORMAT Server was changed. Server status was changed. Group (, %d) was added. Group (, %d) was removed. Group (, %d) was changed. Explore server. The Alarm Service on server sends a test mail. The Alarm Service on server tests a pager. The ServerView Alarm Service Trap Listen Service on server stops. B.4 SNI-HD-MIB (hd.mib ) Traps from FSC HD SMARTMonitoring. snismartfailurepredicted SMART predicted disk failure snismartmonitoringdisable d SMART configuration changed Table: SNI-HD-MIB Trap (ENTERPRISE : enterprises ) (%d: optional number : system 750 CRITICAL SMART predicts failure on disk %d (), adapter %d (), on Server. 751 INFORMAT SMART configuration has been changed on hard disk %d (), adapter %d (), on Server. Warning predicting a disk error. Contact an office listed in the "Contact This message appears when SMART mode has been changed. 20

21 B.5 SERVERVIEW-STATUS-MIB (status.mib) B.5 SERVERVIEW-STATUS-MIB (status.mib) Traps from the ServerView status agent. siesttrapstatuschanged Status changed Table: SERVERVIEW-STATUS-MIB Trap (ENTERPRISE : enterprises ) 1100 INFORMAT (%d: optional number : system System status has changed at server. For the cause of this Trap, check the previous or next Trap ((AlarmService (Alarm Monitor)/OS Event log) ( pg.4). No response is require when there is no Trap. B.6 FSC-SERVERCONTROL2-MIB (sc2.mib) Traps from the ServerView agent. Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) sc2traptest Test trap sc2trapcommunicationfailure Communication lost sc2trapcommunicationestabl ished Communication established sc2trapcontrollerselftestwar ning Controller selftest warning sc2trapcontrollerselftesterror Controller selftest error sc2trapbiosselftesterror Critical BIOS selftest error 2000 INFORMAT (%d: optional number : system Test trap from server (no error) MINOR Communication with the Server Management controller in cabinet %d of server lost INFORMAT Communication with the Server Management controller in cabinet %d of server established again MINOR The Server Management controller in cabinet %d has detected an minor problem during selftest of server CRITICAL The Server Management controller in cabinet %d of server failed CRITICAL A critical error happend while BIOS selftest in cabinet %d of server. See server management message log (recovery log) for detailed information. No error. If recovered in event ID:12002 there is no problem. If not restored, contact an office listed in the "Contact Information" of "Start This message appears when communication with the Server Management controller has recovered. No problem. If multiple messages are detected, it is possible that the Server Management controller has failed. Contact an office listed in the "Contact Contact an office listed in the "Contact 21

22 B Trap List sc2trapseveresystemerror The system was restarted after a severe problem sc2trapfanadded Fan added sc2trapfanremoved Fan removed sc2trapfanok Fan OK sc2trapfancritical Fan failure predicted sc2trapfanfailed Fan failed sc2trapredundantfanfailed Redundant fan failed sc2traptempok Temperature normal sc2traptempwarning Temperature warning sc2traptempcritical Temperature critical Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) sc2traptempsensorok Temperature sensor OK 2006 CRITICAL The system was restarted after a severe problem at cabinet %d of server. See server management message log (recovery log) for detailed information INFORMAT 2011 INFORMAT 2012 INFORMAT Fan '' was added into cabinet %d of server. Fan '' was removed from cabinet %d of server. Fan '' in cabinet %d of server is working again MAJOR Fan '' will fail in near future in cabinet %d of server CRITICAL Fan '' failed in cabinet %d of server MAJOR The redundant fan '' failed in cabinet %d of server. System can become critical if another fan in this group fails INFORMAT Temperature at sensor '' in cabinet %d of server is within normal range MAJOR Temperature at sensor '' in cabinet %d of server '' has reached the warning level CRITICAL Temperature at sensor '' in cabinet %d of server has reached the critical level INFORMAT (%d: optional number : system Temperature sensor '' in cabinet %d of server is working again. A serious problem has occurred on your system. and contact an office listed in the "Contact The fan was added by the operator. The fan was removed by the operator. This message shows that the fan has returned to normal. This message appears when a fan is replaced. This predicts a fan error. A failure will not occur soon. Contact an office listed in the "Contact Information" of "Start A fan error occurred. Contact an office listed in the "Contact A redundant fan failure has occurred. Contact an office listed in the "Contact The internal temperature of the server is within the normal range. No error. A device temperature error occurred. Check the room temperature. If room temperature is normal check whether the fan has failed. Other errors in hardware are possible. Contact an office listed in the "Contact Information" of "Start This message appears when the temperature sensor recovers. 22

23 B.6 FSC-SERVERCONTROL2-MIB (sc2.mib) sc2traptempsensorbroken Temperature sensor broken sc2trappowersupplyadded Power supply added sc2trappowersupplyremoved Power supply removed sc2trappowersupplyok Power supply OK sc2trappowersupplycritical Power supply critical sc2trappowersupplyfailed Power supply failed sc2trapredundantpowersupp lyfailed Redundant power supply failed sc2trappowersupplyredunda ncylost Power supply redundancy lost sc2trapacfail AC failed sc2trapdcfail Power failed Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) 2024 MAJOR Temperature sensor '' in cabinet %d of server is broken or not connected INFORMAT 2031 INFORMAT 2032 INFORMAT (%d: optional number : system Power supply '' in cabinet %d at server was added. Power supply '' in cabinet %d at server was removed Power supply '' in cabinet %d at server is working again CRITICAL Insufficiant operating power supplies available in cabinet %d at server MAJOR Power supply '' in cabinet %d at server failed MAJOR Redundant power supply '' in cabinet %d at server failed. System can become critical if another power supply fails MINOR Power supply redundancy in cabinet %d at server lost. System will become critical if a power supply fails. Temperature sensor may be faulty. Contact an office listed in the "Contact The power supply unit was added by the operator. The power supply unit was removed by the operator. This message appears after the power supply unit has been attached. Install the power supply unit. The PSU has failed. Contact an office listed in the "Contact A redundant power supply failure has occurred. Contact an office listed in the "Contact Power supply unit error. Contact an office listed in the "Contact 2040 CRITICAL AC failure in cabinet %d of server. This message is stored when performing UPS scheduled operations. There is no problem in this case. When not performing UPS scheduled operations, there is a possibility of a power supply error. Contact an office listed in the "Contact Information" of "Start 2041 CRITICAL DC power failure in cabinet %d of server. Power supply unit error. Contact an office listed in the "Contact 23

24 B Trap List sc2traponbattery AC failed, on battery sc2traponmains AC OK sc2trapvoltageok Voltage OK sc2trapvoltagetoolow Voltage too low sc2trapvoltagetoohigh Voltage too high sc2trapvoltagefailed Voltage out of range Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) sc2trapbatteryvoltageprefail Battery failure predicted sc2trapcorrectablememerror Addr Correctable memory error sc2trapuncorrectablememerr oraddr Uncorrectable memory error sc2trapcorrectablememerror Bank Correctable memory error 2042 CRITICAL AC failure. Cabinet %d is running on battery power since %d seconds. In %d minutes server will shutdown INFORMAT 2050 INFORMAT Mains returned after power failure in cabinet %d at server. Power supply voltage '' in cabinet %d at server is within normal range again CRITICAL Power supply voltage '' in cabinet %d at server is too low CRITICAL Power supply voltage '' in cabinet %d at server is too high CRITICAL Power supply voltage '' in cabinet %d at server is out of range MAJOR Battery voltage '' in cabinet %d at server : Battery is predicted to fail in near future INFORMAT Correctable memory error at address %d in cabinet %d of server CRITICAL Uncorrectable memory error at address %d in cabinet %d of server INFORMAT (%d: optional number : system Correctable memory error at bank '' in cabinet %d of server. Running on UPS battery power. Check that UPS power cables are not unplugged and there has been no power interruption. Stopped running on the UPS battery. The server voltage has recovered. There is no problem. A problem may have occurred with the power supply unit, AC power supply or the base board etc. Contact an office listed in the "Contact Power supply unit error. Contact an office listed in the "Contact This predicts a power supply unit error. Contact an office listed in the "Contact An SBE (memory single bit error) has occurred. There is no effect because of the existence of ECC memory. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact An SBE (memory single bit) has occurred. This error has no effect as ECC memory is being used. 24

25 B.6 FSC-SERVERCONTROL2-MIB (sc2.mib) Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) sc2trapuncorrectablememerr orbank Uncorrectable memory error sc2trapcorrectablememerror Module Correctable memory error 2063 CRITICAL Uncorrectable memory error at bank '' in cabinet %d of server INFORMAT (%d: optional number : system Correctable memory error at module '' in cabinet %d of server. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact An SBE (memory single bit error) has occurred. This error has no effect as ECC memory is being used. sc2trapuncorrectablememerr ormodule Uncorrectable memory error sc2trapcorrectablememerror Correctable memory error sc2trapuncorrectablememerr or Uncorrectable memory error sc2trapmemerrormodulepref ail Memory module prefailure sc2trapmemerrormodulefaili ng Memory module failing sc2trapmemerrormodulerep laced Memory module replaced 2065 CRITICAL Uncorrectable memory error at module '' in cabinet %d of server INFORMAT Correctable memory error in cabinet %d of server CRITICAL Uncorrectable memory error in cabinet %d of server MAJOR Memory module failure is predicted for module '' in cabinet %d of server MAJOR Memory module '' in cabinet %d of server is failing. Too many errors have occured MAJOR Memory module '' in cabinet %d of server had failed and was replaced by a hot-spare module An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact An SBE (memory single bit error) has occurred. This error has no effect as ECC memory is being used. An MBE (memory multibit error) has occurred. Contact an office listed in the "Contact This predicts a memory error. Contact an office listed in the "Contact Warning predicting a memory error. Contact an office listed in the "Contact Memory error. Contact an office listed in the "Contact 25

26 B Trap List sc2trapmemerrorloggingdis abled Memory error logging disabled sc2trapmemerrorloggingena bled Memory error logging enabled sc2trapmemerroranymodule Replaced Memory module replaced sc2trapmemerrorredundanc ylost Memory redundancy lost sc2trapcpuspeedchanged CPU speed changed sc2trapcpuprefail CPU prefailure Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) sc2trapcabinetswitchedoff Cabinet switched off sc2trapcabinetswitchedon Cabinet switched on sc2trappowerofftimereached Power off time reached sc2trapservershutdown Server shutdown 2071 MINOR Too many correctable memory errors in cabinet %d at server. Error logging was disabled.\nif logging was disabled and not automatically enabled again, you have to reboot your server to enable memory error logging again.\nif logging is disabled, prefailure detection is also not active! 2072 MINOR Error logging was enabled again in cabinet %d at server (after being disabled because of too many errors) 2073 MAJOR A memory module in cabinet %d of server had failed and was replaced by a hot-spare module 2074 MAJOR Memory configuration in cabinet %d of server has lost redundancy 2080 INFORMAT CPU speed at server changed to %d percent of its maximum speed MAJOR CPU failure is predicted for CPU '' in cabinet %d of server INFORMAT 2091 INFORMAT 2092 INFORMAT 2093 INFORMAT (%d: optional number : system Cabinet %d was switched off because of (server ). Cabinet %d was switched on because of (server ). The power-off time is reached in cabinet %d on server! System shutdown in %d minutes. The reason causes a shutdown at server. Warning predicting a memory error. Contact an office listed in the "Contact Warning predicting a memory error. Contact an office listed in the "Contact Memory error. Contact an office listed in the "Contact Memory error. Contact an office listed in the "Contact The speed of the CPU is lowered because of the high temperature of the CPU. Check CPU temperature. A broken fan may be causing the temperature of the CPU to rise. Warning predicting a CPU error. Contact an office listed in the "Contact Server has turned off. Server has turned on. Shut down is performed due to an order by the ServerView console or a power off scheduled in ServerView. Shutdown at the server is performed by ordering shutdown. 26

27 B.7 FSC-THRESHOLD-REPORT-MIB (Threshold.mib) Table: FSC-SERVERCONTROL2-MIB Trap (ENTERPRISE : enterprises ) sc2trapshutdowncancelled Shutdown cancelled sc2trapbootretrycountzero Boot retry counter zero sc2trapmessagelogfull Message log full sc2trapmessagelogwarning Message log warning sc2trapbootmessagelogentry Error in message log sc2trapintrusionassertion Front door or housing opened sc2trapintrusiondeassertion Front door or housing closed sc2trapintrusionchanged Front door or housing opened/ closed 2094 INFORMAT Shutdown at server cancelled by the user. Shutdown at the scheduled operation or ASR&R (etc.) is canceled by an operator MAJOR Boot retry counter is zero on server. Operations were performed for the amount of retry counters set. Set the retry counters again MINOR The System Event Log on server in cabinet %d is full. No more messages can be logged! Please clear unneeded log entries as soon as possible! 2101 MINOR The System Event Log for cabinet %d at server has exceeded %d%% of its capacity MAJOR An error was recorded on server before the management agents were started (boot phase). See server management message log (Recovery log) for detailed information MAJOR The front door or housing of cabinet %d was opened on server INFORMAT (%d: optional number : system The front door or housing of cabinet %d was closed on server MAJOR The front door or housing of cabinet %d was opened or closed on server. Clear the unnecessary System Event Log using the maintenance tools attached to the hardware. This predicts a System Event Log. Clear the unnecessary System Event Log using the maintenance tools attached to the hardware. Boot error. Refer to SEL for details and contact an office listed in the "Contact Information" of "Start The front door or housing of cabinet was opened. The front door or housing of cabinet was closed. The front door or housing of cabinet was opened or closed. B.7 FSC-THRESHOLD-REPORT-MIB (Threshold.mib) Traps from the Performance manager. Table: FSC-THRESHOLD-REPORT-MIB Trap (ENTERPRISE : enterprises ) nsnotifystart The agent has started running. threshtrapthresholdexceeded Major Threshold exceeded (major) (%d: optional number : system 2200 CRITICAL An indication that the agent has started running MAJOR Threshold exceeded at server. The rule met condition with value. Rule user comment: 27

28 B Trap List Table: FSC-THRESHOLD-REPORT-MIB Trap (ENTERPRISE : enterprises ) threshtrapthresholdexceeded Minor Threshold exceeded (minor) threshtrapthresholdexceeded Informational Threshold exceeded (informational) threshtrapthresholdresume Threshold resume 2202 MINOR Threshold exceeded at server. The rule met condition with value. Rule user comment: 2203 INFORMAT 2204 INFORMAT (%d: optional number : system Threshold exceeded at server. The rule met condition with value. Rule user comment: Threshold resume at server. The rule does no longer meet condition with value. Rule user comment: B.8 FSC-RAID-MIB (raid.mib) Traps from ServerView RAID. Refer to the ServerView RAID manual for details. B.9 SIEMENS-MULTIPATH-MIB (mp.mib) Traps from FSC MultiPath SNMP agent's. siemperror MP: Last port failed siempretry MP: Port failed siempactiveportchanged MP: Port activated siempreconfigured MP: Port added/removed siempstatuschanged MP: Behavior changed siempautorecovered MP: Port alive again siemperrorcleared MP: Status cleared Table: SIEMENS-MULTIPATH-MIB Trap (ENTERPRISE : enterprises ) (%d: optional number : system 1200 CRITICAL MultiPath group %d on server is down MAJOR Port %d of MultiPath group %d on server is down. Error on ID %d, Lun %d INFORMAT 1203 INFORMAT 1204 INFORMAT 1205 INFORMAT 1206 INFORMAT Active port for MultiPath group %d changed on server. Port %d is now active port. MultiPath group %d reconfigured on server. Port %d was affected. MultiPath behavior for group %d was changed on server. MultiPath group %d on server : Port %d recovered from error. MultiPath group %d on server : Error for MultiPath port %d was cleared. 28

About This Manual. Trademarks. ServerView Trap List

About This Manual. Trademarks. ServerView Trap List ServerView Trap List About This Manual A Trap List Overview This section explains how to read the trap list table and the screen display examples. B Trap List This section explains the trap list according

More information

ServerView Event Manager

ServerView Event Manager User Guide - English FUJITSU Software ServerView Suite ServerView Event Manager ServerView Operations Manager V8.00 Edition May 2017 Comments Suggestions Corrections The User Documentation Department would

More information

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide.   support.dell.com Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5 User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

ServerView [ ] [ ] [ Disabled. Connection Type dial-in/out dial-in/out with extension

ServerView [ ] [ ] [ Disabled. Connection Type dial-in/out dial-in/out with extension P3FY-A047-01 PRIMERGY N800 Windows NT ServerView [ ] [ ] [ ] JST LAN Disabled Connection Type dial-in/out dial-in/out with extension Remote Control Service Remote Control Service [ ] [ ] 1 Voltage too

More information

Dell EMC OpenManage Message Reference Guide. Version 9.1

Dell EMC OpenManage Message Reference Guide. Version 9.1 Dell EMC OpenManage Message Reference Guide Version 9.1 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Server Administrator Version 8.5 Messages Reference Guide

Server Administrator Version 8.5 Messages Reference Guide Server Administrator Version 8.5 Messages Reference Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller.

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller. MegaRAID SAS User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter provides an overview

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Integrated Mirroring SAS User s Guide Areas Covered Before Reading This Manual Chapter 1 Chapter 2 Chapter 3 This section explains the notes for your safety and conventions used in this manual. Overview

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. ServerView User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of ServerView This chapter explains

More information

Server Administrator Version 7.4 Messages Reference Guide

Server Administrator Version 7.4 Messages Reference Guide Server Administrator Version 7.4 Messages Reference Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION

More information

A ServerView Web JST JST. Connection Type dial-in/out dial-in/out with extension Web [Serial Line Configuration] [Connection Type] direct

A ServerView Web JST JST. Connection Type dial-in/out dial-in/out with extension Web [Serial Line Configuration] [Connection Type] direct Windows NT ServerView [ ] [ ] [ ] [ ] JST JST Connection Type dial-in/out dial-in/out with extension Web [Serial Line Configuration] [Connection Type] direct REMCS REMCS REMCS ServerView Web ServerView

More information

NEC Express5800 Series NEC ESMPRO Agent User's Guide

NEC Express5800 Series NEC ESMPRO Agent User's Guide NEC Express5800 Series NEC ESMPRO Agent User's Guide PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable

More information

ThinkSystem SR650 Messages and Codes Reference

ThinkSystem SR650 Messages and Codes Reference ThinkSystem SR650 Messages and Codes Reference Machine Types: 7X05 and 7X06 Note Before using this information and the product it supports, be sure to read and understand the safety information and the

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Onboard SCSI RAID User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter explains an

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

Configuring Platform Event Filters

Configuring Platform Event Filters This chapter includes the following sections: Platform Event Filters, page 1 Enabling Platform Event Alerts, page 1 Disabling Platform Event Alerts, page 2, page 2 Configuring SNMP Trap Settings, page

More information

FUJITSU Software ServerView

FUJITSU Software ServerView User Guide - English FUJITSU Software ServerView Linux Server Integration Pack V8.4 for MS SCOM January 2018 Edition Copyright 2018 FUJITSU LIMITED All hardware and software names used are trademarks of

More information

NEC ESMPRO AlertManager User's Guide

NEC ESMPRO AlertManager User's Guide NEC ESMPRO AlertManager User's Guide Chapter 1 General Description Chapter 2 Installation Chapter 3 Setting Chapter 4 Appendix AM_E-UG-W-001-01-004 NEC Corporation 2014 Contents Contents... 2 Notations

More information

ZKLWHýSDSHU. 3UHð)DLOXUHý:DUUDQW\ý 0LQLPL]LQJý8QSODQQHGý'RZQWLPH. +3ý 1HW6HUYHUý 0DQDJHPHQW. Executive Summary. A Closer Look

ZKLWHýSDSHU. 3UHð)DLOXUHý:DUUDQW\ý 0LQLPL]LQJý8QSODQQHGý'RZQWLPH. +3ý 1HW6HUYHUý 0DQDJHPHQW. Executive Summary. A Closer Look 3UHð)DLOXUHý:DUUDQW\ý 0LQLPL]LQJý8QSODQQHGý'RZQWLPH ZKLWHýSDSHU Executive Summary The Hewlett-Packard Pre-Failure Warranty 1 helps you run your business with less downtime. It extends the advantage of

More information

Areas Covered. Chapter 1 Features (Product Overview/Note) Chapter 2 Installation Flow and Note. Chapter 3 Installing Global Array Manager (GAM)

Areas Covered. Chapter 1 Features (Product Overview/Note) Chapter 2 Installation Flow and Note. Chapter 3 Installing Global Array Manager (GAM) PRIMERGY RX200 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Product Overview/Note) This chapter explains the overview of the disk array and features of this product. Chapter 2 Installation

More information

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak Version 5b Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak This document describes the procedures for protecting data and restoring array status to arrays that have gone OFFLINE. Promise

More information

Guide to SiS RAID Utility for Windows XP / 2000

Guide to SiS RAID Utility for Windows XP / 2000 Guide to SiS RAID Utility for Windows XP / 2000 1. General 1. After installing the SiS RAID utility, go to Start menu and choose Programs. From the Programs menu, choose SiS RAID Utility and click on SiSRaid

More information

NEC ESMPRO AlertManager User's Guide (Windows)

NEC ESMPRO AlertManager User's Guide (Windows) NEC ESMPRO AlertManager User's Guide (Windows) Chapter 1 General Description Chapter 2 Installation Chapter 3 Setting Chapter 4 Appendix 10.111.01-129.01 NEC Corporation 2016 Contents Contents... 2 Conventions

More information

Notice for Express Report Service (MG)

Notice for Express Report Service (MG) NEC Express5800, ilo Embedded Server Notice for Express Report Service (MG) Revision 1.0 Nov 22, 2017 NEC Corporation Table of Contents Table of Contents... 2 Trademarks... 3 Cautions... 3 Reference Sites...

More information

VX3000-E Unified Network Storage

VX3000-E Unified Network Storage Datasheet VX3000-E Unified Network Storage Overview VX3000-E storage, with high performance, high reliability, high available, high density, high scalability and high usability, is a new-generation unified

More information

FUJITSU Software ServerView

FUJITSU Software ServerView User Guide - English FUJITSU Software ServerView Windows Server Integration Pack V8.2 for MS SCOM August 2017 Edition Copyright 2016 FUJITSU LIMITED All hardware and software names used are trademarks

More information

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems Configuration Tool and Utilities v3.25 Operation Manual for Fusion RAID Storage Systems Contents 1.0 ATTO Configuration Tool Overview... 1 About the Configuration Tool Configuration Tool Launch Configuration

More information

Cisco Prime Collaboration Deployment Configuration and Administration

Cisco Prime Collaboration Deployment Configuration and Administration Cisco Prime Collaboration Deployment Configuration and Administration Services, page 1 Limitations and Restrictions, page 5 Services After the installation of the Cisco Prime Collaboration Deployment platform,

More information

Configuring Platform Event Filters

Configuring Platform Event Filters This chapter includes the following sections: Platform Event Filters, page 1 Enabling Platform Event Alerts, page 1 Disabling Platform Event Alerts, page 2, page 2 Configuring SNMP Trap Settings, page

More information

NetBackup Appliance SNMP Trap Reference Guide

NetBackup Appliance SNMP Trap Reference Guide NetBackup Appliance SNMP Trap Reference Guide Veritas Appliance SNMP Trap Reference Guide Release 3.0 Legal Notice Copyright 2017 Veritas Technologies LLC. All rights reserved. Veritas, the Veritas Logo,

More information

ServerView Integration V4.0 in HP Operations Manager

ServerView Integration V4.0 in HP Operations Manager User Guide - English FUJITSU Software ServerView Suite ServerView Integration V4.0 in HP Operations Manager Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC) User Guide - English FUJITSU Software ServerView Suite Local Service Panels Local Service Concept (LSC) Last Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

VX1800 Series Unified Network Storage

VX1800 Series Unified Network Storage Datasheet VX1800 Series Unified Network Storage Overview VX1800 series storage, with high performance, high reliability, high density, high scalability and high usability, is a new-generation unified network

More information

AssuredSAN Event Descriptions Reference Guide

AssuredSAN Event Descriptions Reference Guide AssuredSAN Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported

More information

FUJITSU Software ServerView

FUJITSU Software ServerView User Guide - English FUJITSU Software ServerView ESXi Server Integration Pack V8.4 for MS SCOM January 2018 Edition Copyright 2018 FUJITSU LIMITED All hardware and software names used are trademarks of

More information

ForeScout CounterACT. Resiliency Solutions. CounterACT Version 8.0

ForeScout CounterACT. Resiliency Solutions. CounterACT Version 8.0 ForeScout CounterACT Resiliency Solutions CounterACT Version 8.0 Table of Contents About ForeScout Resiliency Solutions... 4 Comparison of Resiliency Solutions for Appliances... 5 Choosing the Right Solution

More information

FAULT TOLERANT SYSTEMS

FAULT TOLERANT SYSTEMS FAULT TOLERANT SYSTEMS http://www.ecs.umass.edu/ece/koren/faulttolerantsystems Part 18 Chapter 7 Case Studies Part.18.1 Introduction Illustrate practical use of methods described previously Highlight fault-tolerance

More information

Intel Server Control Installation and User s Guide. Order Number:

Intel Server Control Installation and User s Guide. Order Number: Intel Server Control Installation and User s Guide Order Number: 700953-010 Revision History The following table lists the current version of Intel Server Control (ISC) software. The date indicates the

More information

FUJITSU Software ServerView

FUJITSU Software ServerView User Guide - English FUJITSU Software ServerView Linux Server Integration Pack V8.3 for MS SCOM June 2017 Edition Copyright 2017 FUJITSU LIMITED All hardware and software names used are trademarks of their

More information

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux-

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- CA92344-0702-02 Table of Contents Preface P.3 1. Operation Status Monitoring 1.1 System Monitoring Overview P.6 1.2

More information

C122-E159-02EN PRIMEQUEST 1000 Series Notices for ServerView Suite

C122-E159-02EN PRIMEQUEST 1000 Series Notices for ServerView Suite PRIMEQUEST 1000 Series Notices for ServerView Suite 2012 January FUJITSU LIMITED Contents I. Preface... 3 II. Notices for ServerView Suite V10.11.07... 4 1. Notices for ServerView Operations Manager (SVOM)...

More information

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3 PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000 User Manual Version 1.3 Promise Array Management Copyright 2003 Promise Technology, Inc. All Rights Reserved. Copyright by

More information

PRIMERGY RX800 S2/S3 RemoteView Management Board RSA-II

PRIMERGY RX800 S2/S3 RemoteView Management Board RSA-II Produktfamilie PRIMERGY RX800 S2/S3 RemoteView Management Board RSA-II User Manual Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e-mail: email: manuals@fujitsu-siemens.com Tel.:

More information

User Guide - English. FUJITSU Software ServerView Suite. Web Interface. Edition December

User Guide - English. FUJITSU Software ServerView Suite. Web Interface. Edition December User Guide - English FUJITSU Software ServerView Suite irmc S5 Web Interface Edition December Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this

More information

Express5800/320La System Release Notes

Express5800/320La System Release Notes System Release Notes Express5800/320La System Release Notes PN: 455-01623-003 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

HPE StoreVirtual OS v13.5 Release Notes

HPE StoreVirtual OS v13.5 Release Notes HPE StoreVirtual OS v13.5 Release Notes Part Number: 865552-006 Published: May 2017 Edition: 2 Contents Release notes...4 Description... 4 Platforms supported for this release... 4 Update recommendation...4

More information

SIMATIC IPC DiagMonitor SIMATIC. Industrial PC. SIMATIC IPC DiagMonitor. Introduction. SIMATIC IPC DiagMonitor. software components.

SIMATIC IPC DiagMonitor SIMATIC. Industrial PC. SIMATIC IPC DiagMonitor. Introduction. SIMATIC IPC DiagMonitor. software components. Introduction 1 software components 2 SIMATIC Industrial PC Operating Manual Quick-Start Guide 3 Hardware and software requirements 4 Installing and removing the software 5 Description of the DiagMonitor

More information

MSA Event Descriptions Reference Guide

MSA Event Descriptions Reference Guide MSA Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported during

More information

ServerView System Monitor

ServerView System Monitor User Guide - English FUJITSU Software ServerView Suite ServerView System Monitor (Part of ServerView Agents up to V7.20 for Windows and Linux) Edition August 2017 Comments Suggestions Corrections The User

More information

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version

More information

White Paper ServerView Agents Retrieving System Status via SNMP

White Paper ServerView Agents Retrieving System Status via SNMP White Paper ServerView Agents Retrieving System Status via SNMP This paper describes how to retrieve the general system status on Fujitsu s PRIMERGY and PRIMEQUEST servers by using SNMP commands directed

More information

ThinkSystem SR850 Messages and Codes Reference

ThinkSystem SR850 Messages and Codes Reference ThinkSystem SR850 Messages and Codes Reference Machine Type: 7X18 and 7X19 Note Before using this information and the product it supports, be sure to read and understand the safety information and the

More information

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux-

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- C122-A017-01EN Table of Contents Preface P.3 1. Operation Status Monitoring 1.1 System Monitoring Overview P.6 1.2

More information

Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And System Center Essentials User s Guide

Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And System Center Essentials User s Guide Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And System Center Essentials User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

IBM FlashSystem 720 & FlashSystem 820 Remote Support Overview

IBM FlashSystem 720 & FlashSystem 820 Remote Support Overview IBM FlashSystem 720 & FlashSystem 820 Remote Support Overview Copyright IBM Corporation 2014 i Applicable Products Product: IBM FlashSystem 720 Product Version(s): 6.3.1-p10, 6.3.0 Product: IBM FlashSystem

More information

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E Sidewinder Hardware Guide Models S1104, S2008, S3008 Revision E Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Models and features... 4 Supported software...

More information

UCS-E160DP Double-wide E-Series Server, 6 core CPU, with PCIe

UCS-E160DP Double-wide E-Series Server, 6 core CPU, with PCIe Overview This chapter includes the following sections: Cisco UCS E-Series Servers Overview, page 1 Server Software, page 2 CIMC Overview, page 3 CIMC GUI, page 3 Cisco UCS E-Series Servers Overview The

More information

The following modifications have been made to this version of the DSM specification:

The following modifications have been made to this version of the DSM specification: NVDIMM DSM Interface Revision V1.6 August 9, 2017 The following modifications have been made to this version of the DSM specification: - General o Added two tables of supported Function Ids, Revision Ids

More information

HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide

HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide Part number: 591224-003 First edition: September 2010 Legal and notice information Copyright 2010 Hewlett-Packard Development Company,

More information

Monitoring Notifications

Monitoring Notifications CHAPTER 4 This chapter describes the Cisco 10000 Series router notifications supported by the MIB enhancements feature introduced in Cisco IOS Release 12.2xxxx. SNMP uses notifications to report events

More information

Sidewinder Control Center. Hardware Guide Models C1015, C2050, and C3000. Revision C

Sidewinder Control Center. Hardware Guide Models C1015, C2050, and C3000. Revision C Sidewinder Control Center Hardware Guide Models C1015, C2050, and C3000 Revision C Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Model features...4 Network

More information

NetIQ AppManager for Siemens ServerView. Management Guide

NetIQ AppManager for Siemens ServerView. Management Guide NetIQ AppManager for Siemens ServerView Management Guide February 2012 Legal Notice THIS DOCUMENT AND THE SOFTWARE DESCRIBED IN THIS DOCUMENT ARE FURNISHED UNDER AND ARE SUBJECT TO THE TERMS OF A LICENSE

More information

HP integrated Citrix XenServer Online Help

HP integrated Citrix XenServer Online Help HP integrated Citrix XenServer Online Help Part Number 486855-002 September 2008 (Second Edition) Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to

More information

Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager User's Guide

Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager User's Guide Dell Server PRO Management Pack 3.0.1 for Microsoft System Center Virtual Machine Manager User's Guide Notes, Cautions, and s NOTE: A NOTE indicates important information that helps you make better use

More information

RMS Alarms. Fault Manager Server Alarms

RMS Alarms. Fault Manager Server Alarms Fault Manager Server Alarms, page 1 Upload Server Alarms, page 5 Upload Server Syslog Messages, page 10 PMG Alarms, page 11 PMG Server Syslog Messages, page 15 PAR System Alarms, page 16 PNR System Alarms,

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Remote Management Controller User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview of Remote Management

More information

Integrate APC Smart UPS

Integrate APC Smart UPS Publication Date: November 18, 2016 Abstract This guide provides instructions to configure APC Smart-UPS to send the syslog events to EventTracker. Scope The configurations detailed in this guide are consistent

More information

ExpressCluster X SingleServerSafe 3.2 for Windows. Operation Guide. 2/19/2014 1st Edition

ExpressCluster X SingleServerSafe 3.2 for Windows. Operation Guide. 2/19/2014 1st Edition ExpressCluster X SingleServerSafe 3.2 for Windows Operation Guide 2/19/2014 1st Edition Revision History Edition Revised Date Description First 2/19/2014 New manual Copyright NEC Corporation 2014. All

More information

Configuring and Using Redundant Disks with Cisco MCS

Configuring and Using Redundant Disks with Cisco MCS Configuring and Using Redundant Disks with Cisco MCS Document ID: 9229 Contents Introduction Prerequisites Requirements Components Used Conventions Drive Mirroring (RAID 1) Recognize a Drive Failure Recover

More information

AMS. Overview. Networked. System Manager. SMA workstation. System Management Controller. Serially-connected. SMA workstation.

AMS. Overview. Networked. System Manager. SMA workstation. System Management Controller. Serially-connected. SMA workstation. AMS Overview SMC Device Driver System Manager Network Agent Networked SMA workstation Network System Client Management Application SMC LAN Client LAN Driver SMC RAID Client RAID Driver Serially-connected

More information

PowerVault MD3 Storage Array Enterprise % Availability

PowerVault MD3 Storage Array Enterprise % Availability PowerVault MD3 Storage Array Enterprise 99.999% Availability Dell Engineering June 2015 A Dell Technical White Paper THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

Intel Simple Network Management Protocol (SNMP) Subagent v8.0

Intel Simple Network Management Protocol (SNMP) Subagent v8.0 Intel Simple Network Management Protocol (SNMP) Subagent v8.0 User Guide June 2017 Legal Information INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,

More information

Dell Server PRO Management Pack 3.0 for Microsoft System Center Virtual Machine Manager User's Guide

Dell Server PRO Management Pack 3.0 for Microsoft System Center Virtual Machine Manager User's Guide Dell Server PRO Management Pack 3.0 for Microsoft System Center Virtual Machine Manager User's Guide Notes, Cautions, and s NOTE: A NOTE indicates important information that helps you make better use of

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family SNMP Alert Messages Reference Guide Version 4.3 Abstract This document includes information about the SNMP alert messages that can appear for the Unity platform and UnityVSA. P/N

More information

Machine Administration Guide 2.3

Machine Administration Guide 2.3 Machine Administration Guide 2.3 Preface Purpose This manual is intended for systems where the Solaris(TM) Operating Environment is installed, and explains the Machine Administration functions required

More information

IBM TotalStorage TM NAS Gateway 300 Models G02/G27

IBM TotalStorage TM NAS Gateway 300 Models G02/G27 Helps leverage the power and flexibility of a SAN for IP clients IBM TotalStorage TM NAS Gateway 300 Models G02/G27 IBM, NAS and storage networking The IBM TotalStorage NAS Gateway 300 is part of the overall

More information

Dell PowerEdge R710 Systems Hardware Owner s Manual

Dell PowerEdge R710 Systems Hardware Owner s Manual Dell PowerEdge R710 Systems Hardware Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Advantech eautomation Group. Advantech. SNMP Subagent. User Guide. For Windows. Version <0.97>

Advantech eautomation Group. Advantech. SNMP Subagent. User Guide. For Windows. Version <0.97> Advantech eautomation Group Advantech SNMP Subagent User Guide For Windows Version Revision History Date Version Description Author 2016/10/05 0.97 Update Screenshot Zhirong.Hsu 2016/02/16 0.96

More information

SigmaSystemCenter 3.3 Data Reference Guide

SigmaSystemCenter 3.3 Data Reference Guide SigmaSystemCenter 3.3 Data Reference Guide - Second Edition - Copyright (C) NEC Corporation 2003-2014. Disclaimer of Warranty All the information, text, graphics, links or other items contained within

More information

Using UCS-Server Configuration Utility

Using UCS-Server Configuration Utility CHAPTER 3 This chapter provides information on using the UCS-Server Configuration Utility and contains the following sections: UCS-SCU Interface, page 3-1 Server Inventory, page 3-3 Server Health, page

More information

High Availability and Redundant Operation

High Availability and Redundant Operation This chapter describes the high availability and redundancy features of the Cisco ASR 9000 Series Routers. Features Overview, page 1 High Availability Router Operations, page 1 Power Supply Redundancy,

More information

Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2

Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2 Basics 1 Hardware configuration 2 SIMATIC Process Historian V8.0 Update 1 Management console 3 Process control messages 4 System Manual 04/2012 A5E03916798-02 Legal information Legal information Warning

More information

NOVASCALE. NovaScale R430 F2. Hardware Owner's Manual REFERENCE 86 A1 62FD 00

NOVASCALE. NovaScale R430 F2. Hardware Owner's Manual REFERENCE 86 A1 62FD 00 NovaScale R430 F2 NOVASCALE Hardware Owner's Manual REFERENCE 86 A1 62FD 00 NOVASCALE NovaScale R430 F2 Hardware Owner's Manual Hardware December 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS

More information

Cluster Configuration Design Guide (Linux/PRIMECLUSTER)

Cluster Configuration Design Guide (Linux/PRIMECLUSTER) C122-A007-04EN PRIMEQUEST 1000 Series Cluster Configuration Design Guide (Linux/PRIMECLUSTER) FUJITSU LIMITED Preface This manual describes the network and shared I/O unit information and configuration

More information

Proprietary MIB Reference

Proprietary MIB Reference APPENDIXB This appendix describes the pcube proprietary MIB supported by the SCE platform. A MIB (Management Information Base) is a database of objects that can be monitored by a network management system

More information

1/6. Main. Bios Version System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause. Processor.

1/6. Main. Bios Version System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause. Processor. 2006 3 Main ( ) Bios Version BIOS System Time System Date Hide Diagnostic Messages During Enabled Disabled POST Error Pause Enabled Disabled Processor ( ) Core Frequency CPU Bus Frequency CPU FSB Processor

More information

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Operation Guide. 10/03/2016 4th Edition

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Operation Guide. 10/03/2016 4th Edition EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows Operation Guide 10/03/2016 4th Edition Revision History Edition Revised Date Description 1st 02/09/2015 New manual 2nd 04/20/2015 Corresponds to the internal

More information

Hardware Sentry Knowledge Module for PATROL by Sentry Software Reference Guide

Hardware Sentry Knowledge Module for PATROL by Sentry Software Reference Guide Hardware Sentry Knowledge Module for PATROL by Sentry Software Supporting Hardware Sentry Knowledge Module for PATROL version 1.3 by Sentry Software August 1, 2005 Contacting BMC Software You can access

More information

ServerView Archive Manager

ServerView Archive Manager User Guide - English ServerView Suite ServerView Archive Manager ServerView Operations Manager as of V5.0 Edition February 2018 Comments Suggestions Corrections The User Documentation Department would

More information

ForeScout CounterACT Resiliency Solutions

ForeScout CounterACT Resiliency Solutions ForeScout CounterACT Resiliency Solutions User Guide CounterACT Version 7.0.0 About CounterACT Resiliency Solutions Table of Contents About CounterACT Resiliency Solutions... 5 Comparison of Resiliency

More information

Netfinity White Paper Netfinity Technology Center

Netfinity White Paper Netfinity Technology Center Netfinity White Paper Netfinity Technology Center Integrating IBM Netfinity Manager with Intel LANDesk Server Manager Abstract IBM Netfinity Manager 5.1 offers enhanced integration with LANDesk Server

More information

ReadyNAS OS 6 Desktop Storage Systems

ReadyNAS OS 6 Desktop Storage Systems ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: 102 104 312 314 350 East Plumeria Drive San Jose, CA 95134 USA March 2013 202-11206-02 v1.0 Support Thank you for selecting NETGEAR products.

More information

Image Backup and Recovery Procedures For Windows 7

Image Backup and Recovery Procedures For Windows 7 Image Backup and Recovery Procedures For Windows 7 Thank you for purchasing a Fujitsu computer. Fujitsu is committed to bringing you the best computing experience with your new system. It is very important

More information

Method of notifying exchange time of the service life components for PRIMEQUEST

Method of notifying exchange time of the service life components for PRIMEQUEST Method of notifying of the service life components for PRIMEQUEST 2014/06 FUJITSU LIMITED This manual describes the method of notifying the previous of the and the of the service life components (such

More information

Installation and Troubleshooting Guide

Installation and Troubleshooting Guide 2 Processor/2U-N Systems Installation and Troubleshooting Guide Model EMS Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE:

More information

When an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways:

When an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways: Introduction The.NETpower Card/Box is primarily used to provide a network management function for the UPS. After plugging it into the UPS, you can manage the UPS remotely via an SNMP NMS (Network Management

More information

Monitoring the ACE Web Application Firewall Remotely

Monitoring the ACE Web Application Firewall Remotely CHAPTER 12 Monitoring the ACE Web Application Firewall Remotely This chapter describes how to monitor the system using SNMP and syslog. It covers these topics: About Appliance Monitoring, page 12-81 Using

More information

FUJITSU Software ServerView Mission Critical Option

FUJITSU Software ServerView Mission Critical Option FUJITSU Server PRIMEQUEST2000 Series FUJITSU Software ServerView Mission Critical Option User Manual Version 1.2 Copyright Fujitsu Limited 2014 All hardware and software names used are trademarks of their

More information

UPS SNMPv3 Agent User s Manual

UPS SNMPv3 Agent User s Manual Milpower Source UPS SNMPv3 Agent User s Manual For M359-1 Rev E and higher Agent Firmware version: 2.02.16 Doc: M359_SNMP_UM Rev (5) 20 May 2012 Page 1 of 15 1. Table of contents 1. Table of contents...

More information

McAfee Data Loss Prevention

McAfee Data Loss Prevention Hardware Guide Revision B McAfee Data Loss Prevention Models 4400, 5500, 6600 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage

More information