SeriBox. antrax Datentechnik GmbH

Size: px
Start display at page:

Download "SeriBox. antrax Datentechnik GmbH"

Transcription

1 SeriBox - Interface box with serial or USB interface - PC connection / Read IN and OUT signal information - 3 x INput (TTL level / floating contact) - 3 x OUTput (relay contact) Manual Firmware V

2 Contents General...3 Using the SeriBox...3 Scope of delivery...4 Hardware...4 Technical Features...4 General...4 Power Supply...4 Input circuit...4 Output circuit...5 Interface...5 CE-Marking...5 Screw clamp connections...6 Srew clamp connections...8 INputs...8 OUTputs...8 Supply voltage...9 Serial interface...9 Operation...9 General...9 Installation...10 Initial operation...10 Installation...11 Control by PC software...11 Parameter...12 General command processing...14 Commands

3 General The SeriBox is connected to a serial interface (RS-232) and allows switching ON and OFF of three low-power relays or reading of three digital signals (TTL level or any floating contact) on this interface. Before first use of the SeriBox, please read this instruction manual carefully. It contains information for the correct use and contains important tips for the installation of the SeriBox. The manufacturer does not accept any liability due to improper use of the unit. In this case all guarantee claims are invalid. Using the SeriBox The SeriBox is designed for for switching of resistive loads up to a maximum current of 1000mA at a maximum voltage of 24V per output detection of switching states with TTL level or floating switches in dry, closed residential and office workplaces, or control cabinets. Rules and regulations governing the connection and use of electronic devices and their security regulations must be followed. Safety Instructions Only use the SeriBox indoors and do not subject the unit to moisture or humidity. Only clean the exterior of the SeriBox with a dry cloth. Only load the output circuits of the SeriBox to their mentioned capacity limits. An overload can lead to the SeriBox being destroyed. Do not use the SeriBox in areas used by children. Do not use the SeriBox if one or several parts (case, cable, plug) are damaged or damage may be caused by its location (e.g. falling down). The SeriBox may only be repaired by authorized service personnel. Only connect electrical appliances that have no limit to their switched-on time (i.e. all connected electrical appliances must be able to take continuous current without sustaining damage in the case of a default to the permanently "ON" position.)

4 Scope of delivery Hardware Everything there? Delivery of a SeriBox unit contains: the SeriBox optional: power supply optional: connector plug this manual Technical Features General Protective Class: IP20, only in dry rooms the current switching state of the IN- and OUTputs are signalled by green or yellow LEDs optional: integrated signal button top-hat rail housing, width 4M (= 71mm), colour grey all connections via screw clamp connections or SUB-D Ambient temperature C Storage temperature C UL-listed: housing (NORYL UL 94 V-0) Relay (Meder, UL listed) PCB (FR4, 94 V-0) Standard components Power Supply Power supply: VDC, connection via screw clamps (see below) Output voltage: 5 VDC, connection via screw clamps (optional, see below) Input circuit Connection via screw clamps 1+2, 3+4 and 5+6 Option 1. : Control by remote TTL level (1 = signal-plus, 2 = GND) Option 2. : Via floating contact (1 = signal, 2 = GND), Signal input is used for remote switching on GND potential Switching state is signalled via green LED for each channel - 4 -

5 Output circuit 3 individual OUTput circuits (connections via screw clamps 7+8, 9+10 and 11+12) Maximum switching capacity: 10W Maximum switching voltage: 200VDC Maximum switching current: 1000mA Switching state is signalled via yellow LED for each channel Interface Serial interface (RxD, TxD, GND), 9600,8,N,1 - no handshake 9pol.-SUB-D - connector (male, standard configuration) Connection to PC via standard extension or connection lead CE-Marking In accordance with the Low Current and EMV Guidelines

6 Screw clamp connections IN- and OUTputs SeriBox Signal lamps TEST Signal button (only optional) pol. SUB-D Serial interface Power supply - 6 -

7 Upper row of contacts, numbering from left to right: Contact Description 1 Input 1: Signal 2 Input 1: GND 3 Input 2: Signal 4 Input 2: GND 5 Input 3: Signal 6 Input 3: GND 7 Output circuit 1 (potential free): 1A 8 Output circuit 1 (potential free): 1B 9 Output circuit 2 (potential free): 2A 10 Output circuit 2 (potential free): 2A 11 Output circuit 3 (potential free): 3A 12 Output circuit 3 (potential free): 3A - 7 -

8 Screw clamp connections INputs The Inputs 1 3 on the contacts 1+2, 3+4 and 5+6 can be operated in two different modes: - Control via remote TTL level (control as for example for a 5V electroluminescent diode) - via a floating contact (e.g. the signal input is remotely drawn to GND potential) The relevant distinction is done automatically, no additional settings have to be executed. OUTputs The outputs consist of a floating relay contact. Please note that power shall never exceed a value of 1000mA. Caution: Also switching of 'harmless' signal circuits, may cause large current pikes, when for example capacitors are loaded/unloaded. There is a risk of melting of the relay contacts, that then can not open any more! Lower row of contacts, Numbering from left to right: Contact Description 21 Supply voltage: V (Input) 22 Supply voltage: 0V 23 Output voltage: +5V (optional) 24 Output voltage: 0V (optional) Connector SUB-D, 9pol., male Description Serial interface - 8 -

9 Supply voltage The supply voltage may vary in the range of V (DC), whereas smaller values should be favoured. A supply voltage of 9V or 12V is recommended. Serial interface For connecting the SeriBox to a PC a standard extension or connection lead shall be used. Operation General The SeriBox is connected to a serial interface (RS-232) and allows switching ON and OFF of three low-power relays or reading of three digital signals (TTL level or any floating contact) on this interface. Control through PC is done with clear text command (interface parameter: 9600,8,N,1) so any standard terminal program can be used for operating the SeriBox. For easy control you also may want to use the AntraxServiceSoftware (ASS.EXE), that you can easily download from our website ( Changes to the inputs or pushing of the signal button are reported to the PC. Behaviour of the SeriBox may be largely determined by means of parameters. These settings are stored in the internal, non volatile configuration memory

10 Installation Initial operation Action Reaction Install all cabling (supply voltage, input signals, output signals) Switch ON supply voltage Starting sequence: - the LED will flash in sequence from left to right - after that all LEDs flash one time - optionally (parameter 2) all outputs remain switched OFF or are set back to the last switching state before power- OFF - optionally(parameter 3) the start intro is sent via the serial interface Commands and parameters can be set Changes to the inputs Optionally (parameter 1) all changes to the inputs via the serial interface are reported with: INP1=0 INP1=1 INP2=0 INP2=1 INP3=0 INP3=1 When confirming with the integrated button the SeriBox reports with: BUTTON=0 BUTTON=1-10 -

11 Installation Control by PC software For controlling the SeriBox any terminal program or own software may be used, as long as it can output clear text to the used serial interface. Following we describe control of the SeriBox with the supplied Windows "HyperTerminal": start "HyperTerminal" ("Accessories" "Communication" "HyperTerminal") type in you requested name for the following set-up (e. g. "SeriBox") and choose symbol for ''connect via'' type in the used interface (e. g. COM1) for ''connection settings'' please type in as follows: Bits per second: 9600 Data bits: 8 Parity: none Stoppbits: 1 Flow control: none then choose ''Settings'' "ASCII-Configuration" and confirm "Upon receiving set linefeed at the end of line" (otherwise all reports of the SeriBox are displayed in the same line) press OK to go back with the first typed in letter (e. g. a "?") connection to the SeriBox is set up Please note: If the above settings shall be changed, please make sure to switch to 'offline' first (via the disconnect button)

12 Parameter Behaviours of the SeriBox can be set with the following parameters: Parameter SET1 = 0/1 Function ON/OFF switching of automatic change messages If 1: With changes to the inputs INP1... INP3 the SeriBox reports the corresponding changes with: INP1=0 INP1=1 INP2=0 INP2=1 INP3=0 INP3=1 With pressing of the integrated button the SeriBox reports with: BUTTON=0 BUTTON=1 SET2 = 0/1 Output-Restore after PowerON If 1: The SeriBox switches back to the last switching state after a Power-ON SET3 = 0/1 Output of the intros after PowerON If 1: The SeriBox reports for duty after Power-ON with the following intro: SeriBox (V2.0) INP1=0 INP2=0 INP3=0 OUT1=0 OUT2=0 OUT3=0 BUTTON=0-12 -

13 Automatic change report Output-Restore after PowerON Intro after PowerON with echo Reset-downtime OK - SET1=0 - SET2=1 - SET3=1 - SET4=0 - SET5=5 whereas the current values and parameter are shown. SET4 = 0/1 with echo If 1: Echo function ON for signals via the serial interface. SET5 = n Reset-downtime in seconds See command OUT, valid range: seconds

14 General command processing Commands The SeriBox can be controlled via the following commands: Command (affecting outputs) OUTn = 0/1/R/P Function Switches the specified output ( or all at same time) one OFF reset pulse Examples: OUT 1 = 0 OUT 2 = 1 OUT 3 = R switches OFF output 1 switches ON output 2 triggers a reset impulse at output 3 (always specifies one single output, you cannot specify ''x''!) This command switches the specified output for the ''reset downtime'' (= parameter 5) specified period in the respectively other switching state and backwards. OUT 1 = P Triggers a impulse at output 1 (always specifies one single output, you cannot specify ''x''!) This command switches on the specified output for 0,5 seconds (= impulse length 500 ms) and back OFF. The impulse length cannot be changed. OUT x = 0 OUT x = 1 switches OFF all outputs switches ON all outputs

15 Command (affecting outputs) Function? Query of current switching state of all inputs and outputs with following report (depending on the switching state): INP1=0 INP2=0 INP3=0 OUT1=0 OUT2=0 OUT3=0 BUTTON=0 OK {+}GET Complete query of all switching states and and query of all parameters: SeriBox (V2.0) INP1=0 INP2=0 INP3=0 OUT1=0 OUT2=0 OUT3=0 BUTTON=0 Automatic change report Output-Restore after PowerON Intro after PowerON with Echo Reset-downtime - SET1=0 - SET2=1 - SET3=1 - SET4=0 - SET5=5 OK

16 Following applies at command handover tot he SeriBox, please note: Spaces are ignored Upper and lower case are not distinguished Each command must at least end with CR (character 13) All parameters remain unchanged unless their are explicitly set anew All parameters are stored in a non-volatile configuration memory and also ''survive'' a power failure recognised commands are confirmed with CRLF + 'OK' + CRLF not recognised commands are confirmed with CRLF + '?' + CRLF before sending a command the previous command must have been recognise and confirmed by the SeriBox (confirmation or wait-time)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

AlarmBox-wireless, Type GSM 230V-Box with integrated GSM module and temperature sensor

AlarmBox-wireless, Type GSM 230V-Box with integrated GSM module and temperature sensor AlarmBox-wireless, Type GSM 230V-Box with integrated GSM module and temperature sensor Manual 11.04.2014-1 - Content General Using the AlarmBox-GSM Safety Instructions Scope of Delivery Hardware Software

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Hardware Manual RM CANview

Hardware Manual RM CANview Hardware Manual RM CANview 1998-2005 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cv_hw_e.doc Table of Contents 1 Legal Regulations...3 2 About the CANview...4 3 Important

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Push Button Interface UP 220D31

Push Button Interface UP 220D31 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Control D. Controller Module for Proportional Valve Control. Installation Manual

Control D. Controller Module for Proportional Valve Control. Installation Manual Control D Controller Module Table of Contents Control D 1 1.1 1.2 1.3 1.3.1 1.3.2 1.4 2 3 4 5 5.1 5.2 5.3 6 7 8 Description 3 How To Order 3 Operating Elements 3 Adjustment 4 Operation 4 Auto-adapt 4 Operating

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

Manual 601: : USB/RS232. Specifications. Contents. Options

Manual 601: : USB/RS232. Specifications. Contents. Options Page 1 ATE-601 601: : USB/RS232 I/O Controller - 8 Inputs, 4/8 Relays The ATE-500/600 series is a range of modular I/O controllers. It uses small standardized boards which allows you to configure the system

More information

Thermoelectric Cooler Controller TED1000

Thermoelectric Cooler Controller TED1000 Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions (PS) Fully Configurable Galvanic Isolator Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation

More information

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Cube LAN Gateway. Operating manual BC-LGW-O-TW

Cube LAN Gateway. Operating manual BC-LGW-O-TW Cube LAN Gateway Operating manual BC-LGW-O-TW Package contents Package contents Quantity Item 1x MAX! Cube LAN Gateway 1x 1x 1x 1x 1x 3x Plug-in USB power supply USB cable Network cable Mounting accessories

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

AC5102. Features. Advanced Central Controller

AC5102. Features. Advanced Central Controller AC5102 Advanced Central Controller Features Central controller for SiPass integrated access control systems Support for 500,000 cardholders Support for up to 96 doors Fully supported in SiPass integrated

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

MCX06C Programmable controller

MCX06C Programmable controller Data sheet MCX06C Programmable controller MCX06C is an electronic controller that holds all the typical functionalities of MCX controllers in the 32x74 mm standard size: programmability connection to the

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

DC Connector. Data sheet LINAK.COM/HOMELINE

DC Connector. Data sheet LINAK.COM/HOMELINE DC Connector Data sheet LINAK.COM/HOMELINE DC Connector The DC CONNECTOR is a HOMELINE accessory making it possible to connect a variety of standard articles equipped with a DC plug to your TWINDRIVE TD3

More information

Updating Reader Firmware

Updating Reader Firmware SWH-xxxx Readers Updating Reader Firmware Version C0 Document Part Number UM-096 July 2012 OVERVIEW This document describes how to download new firmware to Software House SWH-4xxx readers. The procedure

More information

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions

More information

MU110-6U. Analog output module 6 channel. User guide

MU110-6U. Analog output module 6 channel. User guide MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)

More information

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Tina 1A Blanking plug

Tina 1A Blanking plug Original instructions Tina 1A Blanking plug ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm 2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

User Manual. Printer P-52RUE

User Manual. Printer P-52RUE User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4

More information

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance Processor-based bargraph with digital display vertical or horizontal MB3 3-digit digital display -199 999 red display, optional green 30 dots bargraph display tricolour adjustment via factory default or

More information

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c. CSMIO-MPG 6-axis Manual Pulse Generator (MPG) Module Rev. 2.0 copyright 2014 CS-Lab s.c. Index 1. General information...3 1.1 Signs used in this guide... 3 1.2 Standards compliance... 4 1.3 Technical data...

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

USB I/O-CARD WITH 32 INPUTS

USB I/O-CARD WITH 32 INPUTS ORDERING NO. 4 016138 489224 Best. Nr. 502176 Control systems, switchgear cabinets Building automation, Home Automation Model construction, model railroads Step motor control and actuators I/O-card for

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide CoolPlug CooLinkHub HVAC Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in

More information

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29 Linienkoppler S KNX Line coupler S KNX Line coupler S KNX 9070880 Status: March 16 (Subject to change) Page 1 of 29 KNX Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Structure

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions USB CONVERTER Operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 5 OPERATING INSTRUCTIONS

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01 PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies

More information

Original instructions Vital 1 Safety module

Original instructions Vital 1 Safety module Original instructions Vital 1 Safety module ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/lowvoltage Read and understand this document Please read and understand this document

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. , GH Q631 0047 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. Using eight floating contacts, it switches

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) FIBER-OPTIC OXYGEN METER OEM-MODULE WITH UART-INTERFACE MANUAL Document Version 1.04 The Piccolo2-OEM is manufactured by PyroScience GmbH Hubertusstr.

More information

LO-LED64 Latched Output Card

LO-LED64 Latched Output Card LO-LED64 Latched Output Card Product ID. : LO-LED64 Rev. : 1.00 Date : Nov 23, 2007 Firmware Rev. : N/A Beta Innovations (c) 2007 http://www.betainnovations.com Table of Contents Connecting the LO-LED64

More information

Solid State Remote Power Controller E /627

Solid State Remote Power Controller E /627 Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves

More information

Network Camera. Quick Guide DC-B1203X. Powered by

Network Camera. Quick Guide DC-B1203X. Powered by Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies PRODUCT MANUAL ABB i-bus KNX SV/S KNX-Power Supplies Contents Contents side 1 General... 3 1.1 Using the product manual...3 1.1.1 Structure of the product manual...4 1.1.2 Notes...4 1.2 Product and functional

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this

More information

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A... Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production

More information

User Manual EzLogger WiFi Ver 02

User Manual EzLogger WiFi Ver 02 User Manual EzLogger WiFi Ver 02 Table of Contents 1 Symbols..................................... 01 2 Safety...................................... 02 3 Installation...................................

More information

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-RO8 and IO-DI8-RO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery

More information

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in injury or death. This equipment

More information

Programmable controller MCX06C

Programmable controller MCX06C MAKING MODERN LIVING POSSIBLE Technical brochure Programmable controller MCX06C Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best

More information

WTS Intelligent Tactile Sensor Module. - User s Manual

WTS Intelligent Tactile Sensor Module. - User s Manual - User s Manual Content 1 Preface... 3 2 Scope of delivery... 4 3 Getting Started... 4 4 Data Acquisition Firmware... 7 5 Communication... 7 6 Configuration using the Built-In Configuration Shell... 7

More information

Model A Mini AC/DC Clamp Meter. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

SCHMIDT Programming Tool SS 20.4xx Instructions for Use

SCHMIDT Programming Tool SS 20.4xx Instructions for Use SCHMIDT Programming Tool SS 20.4xx Instructions for Use SCHMIDT Programming Tool SS 20.4xx Table of Contents 1 Important Information... 3 2 Field of Application... 4 3 Scope of Delivery... 4 4 Programming

More information

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM Englisch Operating Manual Operating Software GHMware 2.02 Unternehmen / Marken der GHM Programming Adapter EYY120 www.ghm-messtechnik.de Retain for further references. Table of Contents Page 1 Intended

More information

SIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation

SIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation USER MANUAL ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation 2 Index 1. Features and Applications... 3 1.1 Functions of the ADJUSTMENT TOOL... 3 1.2 Dynamic Offset and Amplitude Control

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

RТTH DUAL ROOM SWITCH

RТTH DUAL ROOM SWITCH DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA

More information

Programmable controller Type MCX06C

Programmable controller Type MCX06C Programmable controller Type Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best out of your heating, ventilation, air-conditioning

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

VersaPoint I/O Module

VersaPoint I/O Module Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm

More information

HEC. General Operating, Maintenance and Installation Manual

HEC. General Operating, Maintenance and Installation Manual HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...

More information

HDRF BRIDGE. v User Guide

HDRF BRIDGE. v User Guide HDRF BRIDGE v1.0.0.1 User Guide CONTENTS 1 INTRODUCTION/INSTALLER QUICK SETUP... 3 2 PARTS AND ACCESSORIES... 4 3 HDRF BRIDGE FACTORY DEFAULTS... 5 A HDRF DEVICES AND RQ DEVICES INITIAL SETUP... 6 B HDRF

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information