SeriBox. antrax Datentechnik GmbH
|
|
- Garey Cameron
- 5 years ago
- Views:
Transcription
1 SeriBox - Interface box with serial or USB interface - PC connection / Read IN and OUT signal information - 3 x INput (TTL level / floating contact) - 3 x OUTput (relay contact) Manual Firmware V
2 Contents General...3 Using the SeriBox...3 Scope of delivery...4 Hardware...4 Technical Features...4 General...4 Power Supply...4 Input circuit...4 Output circuit...5 Interface...5 CE-Marking...5 Screw clamp connections...6 Srew clamp connections...8 INputs...8 OUTputs...8 Supply voltage...9 Serial interface...9 Operation...9 General...9 Installation...10 Initial operation...10 Installation...11 Control by PC software...11 Parameter...12 General command processing...14 Commands
3 General The SeriBox is connected to a serial interface (RS-232) and allows switching ON and OFF of three low-power relays or reading of three digital signals (TTL level or any floating contact) on this interface. Before first use of the SeriBox, please read this instruction manual carefully. It contains information for the correct use and contains important tips for the installation of the SeriBox. The manufacturer does not accept any liability due to improper use of the unit. In this case all guarantee claims are invalid. Using the SeriBox The SeriBox is designed for for switching of resistive loads up to a maximum current of 1000mA at a maximum voltage of 24V per output detection of switching states with TTL level or floating switches in dry, closed residential and office workplaces, or control cabinets. Rules and regulations governing the connection and use of electronic devices and their security regulations must be followed. Safety Instructions Only use the SeriBox indoors and do not subject the unit to moisture or humidity. Only clean the exterior of the SeriBox with a dry cloth. Only load the output circuits of the SeriBox to their mentioned capacity limits. An overload can lead to the SeriBox being destroyed. Do not use the SeriBox in areas used by children. Do not use the SeriBox if one or several parts (case, cable, plug) are damaged or damage may be caused by its location (e.g. falling down). The SeriBox may only be repaired by authorized service personnel. Only connect electrical appliances that have no limit to their switched-on time (i.e. all connected electrical appliances must be able to take continuous current without sustaining damage in the case of a default to the permanently "ON" position.)
4 Scope of delivery Hardware Everything there? Delivery of a SeriBox unit contains: the SeriBox optional: power supply optional: connector plug this manual Technical Features General Protective Class: IP20, only in dry rooms the current switching state of the IN- and OUTputs are signalled by green or yellow LEDs optional: integrated signal button top-hat rail housing, width 4M (= 71mm), colour grey all connections via screw clamp connections or SUB-D Ambient temperature C Storage temperature C UL-listed: housing (NORYL UL 94 V-0) Relay (Meder, UL listed) PCB (FR4, 94 V-0) Standard components Power Supply Power supply: VDC, connection via screw clamps (see below) Output voltage: 5 VDC, connection via screw clamps (optional, see below) Input circuit Connection via screw clamps 1+2, 3+4 and 5+6 Option 1. : Control by remote TTL level (1 = signal-plus, 2 = GND) Option 2. : Via floating contact (1 = signal, 2 = GND), Signal input is used for remote switching on GND potential Switching state is signalled via green LED for each channel - 4 -
5 Output circuit 3 individual OUTput circuits (connections via screw clamps 7+8, 9+10 and 11+12) Maximum switching capacity: 10W Maximum switching voltage: 200VDC Maximum switching current: 1000mA Switching state is signalled via yellow LED for each channel Interface Serial interface (RxD, TxD, GND), 9600,8,N,1 - no handshake 9pol.-SUB-D - connector (male, standard configuration) Connection to PC via standard extension or connection lead CE-Marking In accordance with the Low Current and EMV Guidelines
6 Screw clamp connections IN- and OUTputs SeriBox Signal lamps TEST Signal button (only optional) pol. SUB-D Serial interface Power supply - 6 -
7 Upper row of contacts, numbering from left to right: Contact Description 1 Input 1: Signal 2 Input 1: GND 3 Input 2: Signal 4 Input 2: GND 5 Input 3: Signal 6 Input 3: GND 7 Output circuit 1 (potential free): 1A 8 Output circuit 1 (potential free): 1B 9 Output circuit 2 (potential free): 2A 10 Output circuit 2 (potential free): 2A 11 Output circuit 3 (potential free): 3A 12 Output circuit 3 (potential free): 3A - 7 -
8 Screw clamp connections INputs The Inputs 1 3 on the contacts 1+2, 3+4 and 5+6 can be operated in two different modes: - Control via remote TTL level (control as for example for a 5V electroluminescent diode) - via a floating contact (e.g. the signal input is remotely drawn to GND potential) The relevant distinction is done automatically, no additional settings have to be executed. OUTputs The outputs consist of a floating relay contact. Please note that power shall never exceed a value of 1000mA. Caution: Also switching of 'harmless' signal circuits, may cause large current pikes, when for example capacitors are loaded/unloaded. There is a risk of melting of the relay contacts, that then can not open any more! Lower row of contacts, Numbering from left to right: Contact Description 21 Supply voltage: V (Input) 22 Supply voltage: 0V 23 Output voltage: +5V (optional) 24 Output voltage: 0V (optional) Connector SUB-D, 9pol., male Description Serial interface - 8 -
9 Supply voltage The supply voltage may vary in the range of V (DC), whereas smaller values should be favoured. A supply voltage of 9V or 12V is recommended. Serial interface For connecting the SeriBox to a PC a standard extension or connection lead shall be used. Operation General The SeriBox is connected to a serial interface (RS-232) and allows switching ON and OFF of three low-power relays or reading of three digital signals (TTL level or any floating contact) on this interface. Control through PC is done with clear text command (interface parameter: 9600,8,N,1) so any standard terminal program can be used for operating the SeriBox. For easy control you also may want to use the AntraxServiceSoftware (ASS.EXE), that you can easily download from our website ( Changes to the inputs or pushing of the signal button are reported to the PC. Behaviour of the SeriBox may be largely determined by means of parameters. These settings are stored in the internal, non volatile configuration memory
10 Installation Initial operation Action Reaction Install all cabling (supply voltage, input signals, output signals) Switch ON supply voltage Starting sequence: - the LED will flash in sequence from left to right - after that all LEDs flash one time - optionally (parameter 2) all outputs remain switched OFF or are set back to the last switching state before power- OFF - optionally(parameter 3) the start intro is sent via the serial interface Commands and parameters can be set Changes to the inputs Optionally (parameter 1) all changes to the inputs via the serial interface are reported with: INP1=0 INP1=1 INP2=0 INP2=1 INP3=0 INP3=1 When confirming with the integrated button the SeriBox reports with: BUTTON=0 BUTTON=1-10 -
11 Installation Control by PC software For controlling the SeriBox any terminal program or own software may be used, as long as it can output clear text to the used serial interface. Following we describe control of the SeriBox with the supplied Windows "HyperTerminal": start "HyperTerminal" ("Accessories" "Communication" "HyperTerminal") type in you requested name for the following set-up (e. g. "SeriBox") and choose symbol for ''connect via'' type in the used interface (e. g. COM1) for ''connection settings'' please type in as follows: Bits per second: 9600 Data bits: 8 Parity: none Stoppbits: 1 Flow control: none then choose ''Settings'' "ASCII-Configuration" and confirm "Upon receiving set linefeed at the end of line" (otherwise all reports of the SeriBox are displayed in the same line) press OK to go back with the first typed in letter (e. g. a "?") connection to the SeriBox is set up Please note: If the above settings shall be changed, please make sure to switch to 'offline' first (via the disconnect button)
12 Parameter Behaviours of the SeriBox can be set with the following parameters: Parameter SET1 = 0/1 Function ON/OFF switching of automatic change messages If 1: With changes to the inputs INP1... INP3 the SeriBox reports the corresponding changes with: INP1=0 INP1=1 INP2=0 INP2=1 INP3=0 INP3=1 With pressing of the integrated button the SeriBox reports with: BUTTON=0 BUTTON=1 SET2 = 0/1 Output-Restore after PowerON If 1: The SeriBox switches back to the last switching state after a Power-ON SET3 = 0/1 Output of the intros after PowerON If 1: The SeriBox reports for duty after Power-ON with the following intro: SeriBox (V2.0) INP1=0 INP2=0 INP3=0 OUT1=0 OUT2=0 OUT3=0 BUTTON=0-12 -
13 Automatic change report Output-Restore after PowerON Intro after PowerON with echo Reset-downtime OK - SET1=0 - SET2=1 - SET3=1 - SET4=0 - SET5=5 whereas the current values and parameter are shown. SET4 = 0/1 with echo If 1: Echo function ON for signals via the serial interface. SET5 = n Reset-downtime in seconds See command OUT, valid range: seconds
14 General command processing Commands The SeriBox can be controlled via the following commands: Command (affecting outputs) OUTn = 0/1/R/P Function Switches the specified output ( or all at same time) one OFF reset pulse Examples: OUT 1 = 0 OUT 2 = 1 OUT 3 = R switches OFF output 1 switches ON output 2 triggers a reset impulse at output 3 (always specifies one single output, you cannot specify ''x''!) This command switches the specified output for the ''reset downtime'' (= parameter 5) specified period in the respectively other switching state and backwards. OUT 1 = P Triggers a impulse at output 1 (always specifies one single output, you cannot specify ''x''!) This command switches on the specified output for 0,5 seconds (= impulse length 500 ms) and back OFF. The impulse length cannot be changed. OUT x = 0 OUT x = 1 switches OFF all outputs switches ON all outputs
15 Command (affecting outputs) Function? Query of current switching state of all inputs and outputs with following report (depending on the switching state): INP1=0 INP2=0 INP3=0 OUT1=0 OUT2=0 OUT3=0 BUTTON=0 OK {+}GET Complete query of all switching states and and query of all parameters: SeriBox (V2.0) INP1=0 INP2=0 INP3=0 OUT1=0 OUT2=0 OUT3=0 BUTTON=0 Automatic change report Output-Restore after PowerON Intro after PowerON with Echo Reset-downtime - SET1=0 - SET2=1 - SET3=1 - SET4=0 - SET5=5 OK
16 Following applies at command handover tot he SeriBox, please note: Spaces are ignored Upper and lower case are not distinguished Each command must at least end with CR (character 13) All parameters remain unchanged unless their are explicitly set anew All parameters are stored in a non-volatile configuration memory and also ''survive'' a power failure recognised commands are confirmed with CRLF + 'OK' + CRLF not recognised commands are confirmed with CRLF + '?' + CRLF before sending a command the previous command must have been recognise and confirmed by the SeriBox (confirmation or wait-time)
Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationAlarmBox-wireless, Type GSM 230V-Box with integrated GSM module and temperature sensor
AlarmBox-wireless, Type GSM 230V-Box with integrated GSM module and temperature sensor Manual 11.04.2014-1 - Content General Using the AlarmBox-GSM Safety Instructions Scope of Delivery Hardware Software
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationHardware Manual RM CANview
Hardware Manual RM CANview 1998-2005 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cv_hw_e.doc Table of Contents 1 Legal Regulations...3 2 About the CANview...4 3 Important
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationPush Button Interface UP 220D31
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationControl D. Controller Module for Proportional Valve Control. Installation Manual
Control D Controller Module Table of Contents Control D 1 1.1 1.2 1.3 1.3.1 1.3.2 1.4 2 3 4 5 5.1 5.2 5.3 6 7 8 Description 3 How To Order 3 Operating Elements 3 Adjustment 4 Operation 4 Auto-adapt 4 Operating
More informationDemonstration Case BENNING DB 1
Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...
More informationManual 601: : USB/RS232. Specifications. Contents. Options
Page 1 ATE-601 601: : USB/RS232 I/O Controller - 8 Inputs, 4/8 Relays The ATE-500/600 series is a range of modular I/O controllers. It uses small standardized boards which allows you to configure the system
More informationThermoelectric Cooler Controller TED1000
Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...
More informationRAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description
I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless
More informationDT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions
(PS) Fully Configurable Galvanic Isolator Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More informationProduct and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation
More informationSCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions
SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationOperating Instructions VEGAMET 381
Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...
More informationCube LAN Gateway. Operating manual BC-LGW-O-TW
Cube LAN Gateway Operating manual BC-LGW-O-TW Package contents Package contents Quantity Item 1x MAX! Cube LAN Gateway 1x 1x 1x 1x 1x 3x Plug-in USB power supply USB cable Network cable Mounting accessories
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationAC5102. Features. Advanced Central Controller
AC5102 Advanced Central Controller Features Central controller for SiPass integrated access control systems Support for 500,000 cardholders Support for up to 96 doors Fully supported in SiPass integrated
More informationProduct and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs
Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).
More informationMCX06C Programmable controller
Data sheet MCX06C Programmable controller MCX06C is an electronic controller that holds all the typical functionalities of MCX controllers in the 32x74 mm standard size: programmability connection to the
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationDC Connector. Data sheet LINAK.COM/HOMELINE
DC Connector Data sheet LINAK.COM/HOMELINE DC Connector The DC CONNECTOR is a HOMELINE accessory making it possible to connect a variety of standard articles equipped with a DC plug to your TWINDRIVE TD3
More informationUpdating Reader Firmware
SWH-xxxx Readers Updating Reader Firmware Version C0 Document Part Number UM-096 July 2012 OVERVIEW This document describes how to download new firmware to Software House SWH-4xxx readers. The procedure
More informationAssembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN
Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions
More informationMU110-6U. Analog output module 6 channel. User guide
MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)
More informationGT- HE910-EUD. Product description Rev. 8 21/02/ Overview
GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface
More informationManual Control Unit GFC 32
Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control
More informationDCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL
DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationTina 1A Blanking plug
Original instructions Tina 1A Blanking plug ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationDevice technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm
2 2.1 Air Quality Sensor LGS/A 1.1 The ABB i-bus KNX Air Quality Sensor 1.1 is a combined sensor for CO 2, temperature and humidity measurement (relative humidity). Three independent thresholds can be
More informationIndustriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH
Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical
More informationUser Manual. Printer P-52RUE
User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4
More informationadjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance
Processor-based bargraph with digital display vertical or horizontal MB3 3-digit digital display -199 999 red display, optional green 30 dots bargraph display tricolour adjustment via factory default or
More informationCSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.
CSMIO-MPG 6-axis Manual Pulse Generator (MPG) Module Rev. 2.0 copyright 2014 CS-Lab s.c. Index 1. General information...3 1.1 Signs used in this guide... 3 1.2 Standards compliance... 4 1.3 Technical data...
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationProduct and functional description
Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationDXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More informationManual Simatek Control Unit GFC 32
Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections
More informationUSB I/O-CARD WITH 32 INPUTS
ORDERING NO. 4 016138 489224 Best. Nr. 502176 Control systems, switchgear cabinets Building automation, Home Automation Model construction, model railroads Step motor control and actuators I/O-card for
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationCoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide
CoolPlug CooLinkHub HVAC Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in
More informationLinienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29
Linienkoppler S KNX Line coupler S KNX Line coupler S KNX 9070880 Status: March 16 (Subject to change) Page 1 of 29 KNX Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Structure
More informationGeneral Operating, Maintenance and Installation Manual
General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:
More informationProduct and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N
Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial
More informationCNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions
USB CONVERTER Operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 5 OPERATING INSTRUCTIONS
More informationUser Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at
User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This
More informationPNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01
PNOZ m ES RS232 Configurable Control System PNOZmulti Operating Manual-1002701-EN-01 This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies
More informationOriginal instructions Vital 1 Safety module
Original instructions Vital 1 Safety module ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/lowvoltage Read and understand this document Please read and understand this document
More informationProduct and functional description
Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationThe 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.
, GH Q631 0047 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. Using eight floating contacts, it switches
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More informationPiccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)
Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM) FIBER-OPTIC OXYGEN METER OEM-MODULE WITH UART-INTERFACE MANUAL Document Version 1.04 The Piccolo2-OEM is manufactured by PyroScience GmbH Hubertusstr.
More informationLO-LED64 Latched Output Card
LO-LED64 Latched Output Card Product ID. : LO-LED64 Rev. : 1.00 Date : Nov 23, 2007 Firmware Rev. : N/A Beta Innovations (c) 2007 http://www.betainnovations.com Table of Contents Connecting the LO-LED64
More informationSolid State Remote Power Controller E /627
Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves
More informationNetwork Camera. Quick Guide DC-B1203X. Powered by
Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationPRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies
PRODUCT MANUAL ABB i-bus KNX SV/S KNX-Power Supplies Contents Contents side 1 General... 3 1.1 Using the product manual...3 1.1.1 Structure of the product manual...4 1.1.2 Notes...4 1.2 Product and functional
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationHDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL
HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this
More informationCoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...
Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production
More informationUser Manual EzLogger WiFi Ver 02
User Manual EzLogger WiFi Ver 02 Table of Contents 1 Symbols..................................... 01 2 Safety...................................... 02 3 Installation...................................
More informationIO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs
IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-RO8 and IO-DI8-RO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The
More informationR5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com
Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery
More informationCoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide
Bridge Quick Installation Guide Warning Read and understand the following Safety Guidelines and Warnings to ensure a safe installation Failure to follow WARNING may result in injury or death. This equipment
More informationProgrammable controller MCX06C
MAKING MODERN LIVING POSSIBLE Technical brochure Programmable controller MCX06C Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best
More informationWTS Intelligent Tactile Sensor Module. - User s Manual
- User s Manual Content 1 Preface... 3 2 Scope of delivery... 4 3 Getting Started... 4 4 Data Acquisition Firmware... 7 5 Communication... 7 6 Configuration using the Built-In Configuration Shell... 7
More informationModel A Mini AC/DC Clamp Meter. User's Guide
Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationSCHMIDT Programming Tool SS 20.4xx Instructions for Use
SCHMIDT Programming Tool SS 20.4xx Instructions for Use SCHMIDT Programming Tool SS 20.4xx Table of Contents 1 Important Information... 3 2 Field of Application... 4 3 Scope of Delivery... 4 4 Programming
More informationEnglisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM
Englisch Operating Manual Operating Software GHMware 2.02 Unternehmen / Marken der GHM Programming Adapter EYY120 www.ghm-messtechnik.de Retain for further references. Table of Contents Page 1 Intended
More informationSIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation
USER MANUAL ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation 2 Index 1. Features and Applications... 3 1.1 Functions of the ADJUSTMENT TOOL... 3 1.2 Dynamic Offset and Amplitude Control
More informationOperating Instructions
TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................
More informationSwitching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX
Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1
More informationOTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m
Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationProgrammable controller Type MCX06C
Programmable controller Type Danfoss range of universal MCX programmable controllers offers the functionality and reliability you need to get the best out of your heating, ventilation, air-conditioning
More informationOPLC Installation Guide
Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs
More informationVersaPoint I/O Module
Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm
More informationHEC. General Operating, Maintenance and Installation Manual
HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version
More information1. Short description. 2. Features. 3. Technical parameters
1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationUSB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL
USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description
More informationCMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual
CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,
More information256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client
User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...
More informationHDRF BRIDGE. v User Guide
HDRF BRIDGE v1.0.0.1 User Guide CONTENTS 1 INTRODUCTION/INSTALLER QUICK SETUP... 3 2 PARTS AND ACCESSORIES... 4 3 HDRF BRIDGE FACTORY DEFAULTS... 5 A HDRF DEVICES AND RQ DEVICES INITIAL SETUP... 6 B HDRF
More informationIO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs
IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationRS485 MODBUS Module 8I8O
Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationVDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2
VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability
More informationIO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs
IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,
More information