1 SCHMIDT Programming Tool SS 20.4xx Instructions for Use
2 SCHMIDT Programming Tool SS 20.4xx Table of Contents 1 Important Information Field of Application Scope of Delivery Programming Box SS 20.4xx Putting the Programming Interface into Operation Programming Tool Operation CE Declaration of Conformity Imprint: Copyright 2006 SCHMIDT Technology All rights reserved. Version and Release Date: Version 1.2 of May 2006 Instructions for Use Programming Tool SS 20.4xx Page 2
3 1 Important Information These instructions for use must be read completely and observed carefully, before putting the unit into operation. Any claims under the manufacturer's liability for damage resulting from non-observance or non-compliance with these instructions will become void. Tampering with the device in any way whatsoever - with the exception of the designated use and the operations described in these instructions for use - will forfeit any warranty and exclude any liability. The unit is designed exclusively for the use described below (s. chapter 2). In particular, it is not designed for direct or indirect personal protection. SCHMIDT Technology cannot give any warranty as to its suitability for a certain purpose and cannot be held liable for errors contained in these instructions for use or for accidental or sequential damage in connection with the delivery, performance or use of this unit. Instructions for Use Programming Tool SS 20.4xx Page 3
4 2 Field of Application The SS 20.4xx Programming Interface allows the function of sensors of the SS 20.4xx sensor family to be checked. In addition, the RS232 interface inside the sensor allows some sensor properties to be configured, operating and measuring data to be read out and displayed in a user-friendly window. The Programming Interface is merely intended for the functional test and for the configuration of the sensor. A permanent field operation or as hand-held device is not recommended. 3 Scope of Delivery The Programming Interface contains the components shown below. Upon receipt, please check the contents for completeness. - Programming box SS 20.4xx - 9V block battery - RS232 interface cable (excluding handshake) - CD containing programming tool and drivers - Instructions for Use Instructions for Use Programming Tool SS 20.4xx Page 4
5 4 Programming Box SS 20.4xx 4.1 Structure and connections The programming box SS 20.4xx consists of a handy, ergonomically shaped housing having the following functional parts (see above figure): - Connections for external components at the top front side of the housing: [1] For a sensor of the SS 20.4xx type: Type: Binder, series 712 (male, 7-pin, shielded, with M9 screw-type lock) [2] For the power supply via an external plug-in power supply unit: Type: 3.5mm jack plug socket (mono) [3] For the RS232 interface connection to the PC: Type: SubD9 socket (female) Instructions for Use Programming Tool SS 20.4xx Page 5
6 - Display and operating elements on the front of the housing: [4] RS232 activity (one LED each for RxD and TxD) [5] Switching states of both switching outputs of the connected sensor (one LED each per output) [6] Flow signal output of the connected sensor (bargraph display containing 10 LEDs) [7] Power LED [8] Rocker switch for switching on the programming box with simultaneous selection of the signal output type of the sensor (voltage or current) 4.2 Power supply of the programming box The programming box requires its own power supply for operation: - Voltage: 9V ±20% - Required current: 50mA max. (including sensor) Make sure that the maximum allowed operating voltage is not exceeded. Higher voltages may destroy the electronics. The power can be supplied in two ways: - For high mobility (e.g. for startup in the field), the box can be supplied internally with power by a 9V block battery or an accumulator of the same design. The battery compartment is at the rear of the box. When operating the device by battery, make sure that it is always charged. - Alternatively, the programming box can be suppled by an external power supply unit (not included in the scope of delivery) via a 3.5 mm monojack socket [2]. Instructions for Use Programming Tool SS 20.4xx Page 6
7 Ensure correct polarity of the operating voltage at the jack plug (see figure opposite). GND +9V When using an external power source, a built-in battery does not have to be taken out, since plugging in the jack plug will automatically switch to the external supply. Therefore, a built-in accumulator cannot be charged via the external connection. After connecting or installing the energy source, the programming box can be switched on on the rocker switch [8]. For a functional test of the box in the absence of a sensor, it is immaterial whether the switch position Voltage or Current is pressed, since this merely distinguishes between the available output types "Voltage" or "Current" of the sensor analog signal. If a sufficient energy supply has been connected correctly, and the box is intact, the green Power LED [7] will light up, signalling the functional readiness. All other luminous diodes remain off, as long as neither a sensor nor a PC is connected. 4.3 Power supply of the programming box The programming box allows the function of the sensor connections to be checked by means of a luminous diode based display area, even independently of the PC. To avoid technical problems, you should always switch off the programming box, before connecting a sensor or disconnecting it from the box. Always switch off the programming box, before plugging in or pulling a sensor. After the sensor has been connected and the programming box has been switched on (observe signal type setting: Voltage or Current), the Power LED [7] will signal readiness of the device. A wrong setting of the signal type is not critical Instructions for Use Programming Tool SS 20.4xx Page 7
8 for the sensor and the programming box technically speaking, but the sensor signal will be displayed incorrectly on the analog display of the box, since its load resistances and amplifications will differ, depending on the signal type 1. Ensure the correct signal type of the sensor (voltage or current) when switching on the box, since otherwise the analog display will show wrong values. In the section Sensor [5], the status of the sensor switching outputs OC1 and OC2 can be checked by means of two red luminous diodes. A single LED will light when it is switched by its corresponding switching output, which has been designed as an open collector, against earth. In the section RS232 [4], an active communication between sensor and PC is signalled by flashing of both LEDs RxD and TxD. In the Analog Out section [6], the analog output signal of the sensor (flow) is represented quasiproportionally and absolutely in the dot mode 2 by means of a 10-digit green LED bargraph display. Of these, each LED corresponds to an approximately 10 percent interval of 10V or 20mA of the analog sensor signal. The relationship between the absolute analog signal range and the corresponding LED can be seen from the following table. 1 For example, a 5V output is not capable of driving the 300Ω load of the current input of the box of up to 20mA. 2 Only the LED corresponding to the current analog value will light up. Instructions for Use Programming Tool SS 20.4xx Page 8
9 Sensor signal output Voltage range [V] Current range [ma] Programming box LED lighting up [No.] 0... < < 2 / 1... < < < < < < < < < < < < < < < < < < 20 9 >= 10 >= Only in the "bottommost" interval, defined as < 1V or < 2mA signal, will no LED light up. In contrast, the "topmost" 10th LED will not light up until the signal amplitude of 10V or 20mA is reached or exceeded. This means that the display of the flow velocity ranges by the individual LEDs depend on the measuring range of the sensor, the type (voltage or current) and amplitude of its signal output and from the display of the flow direction in bidirectional configuration. For example, for a unidirectional sensor having a 4-20 ma interface, the fourth LED will light up from the very start at zero flow (which corresponds to 4mA). Only the upper 16mA display the measuring range of the sensor proportionally. However, in a bidirectional sensor having a 10V voltage output and a zero point display in the middle of the measuring range, i.e., at 5V, the fifth LED will be lit at zero flow. The positive flow range will then be displayed by luminous diodes 6-10, whereas the negative flow intervals will be signalled by LEDs 4-1. Instructions for Use Programming Tool SS 20.4xx Page 9
10 5 Putting the Programming Interface into Operation 5.1 System requirements for PC Operating system: Processor: RAM: Hard disk memory: Windows 2000 / XP Pentium III / Celeron of at least 600MHz 128 MB 155 MB 5.2 Installation of the software Before putting the Programming Interface into operation, you first have to install the programming tool. The CD included in the delivery contains all files necessary for operation. Insert the CD into your drive and open the "setup.exe" file. The installation program will now be executed, please follow the on-screen instructions. To start the software, please click on: Start / Programs / SCHMIDT Technology / Sensor Programming Tool 5.3 Connecting the programming box After starting the software, connect the SubD9 plug on the housing of the programming box to the desired COM port at the PC via the delivered RS232 cable. Before plugging the SS 20.4xx sensor into the connecting socket [1], make sure that the programming box is off ([7], [8]). Always switch off the programming box, before plugging in or pulling a sensor. Now switch on the device on the rocker switch [8] using the correct signal type (setting: Voltage or Current). Communication with the sensor via the PC is now possible. Instructions for Use Programming Tool SS 20.4xx Page 10
11 6 Programming Tool Operation The programming tool SS 20.4xx allows you to change important function parameters of your sensor SS 20.4xx and to read out and analyse measured values. To do so, please start the program Programming Tool SS 20.4xx in the start menu. This will open the main window of the software (see figure opposite) The upper fourth of the window contains the operating and display elements for configuration and status {1} - {6} of the serial interface. Box {7} shows the serial number and box {8} the firmware version of the connected sensor. The left half of the lower window area is exclusively for the configuration of the sensor. The right half of the lower window area shows the measured values and their evaluation. Instructions for Use Programming Tool SS 20.4xx Page 11
12 6.1 Configuration of the RS232 interface After program start, the PortScanning function {1} is off by default (disabled). This allows you first to configure the interface. Select the correct serial COM port at the PC {2} and the desired baud rate {3} (default: 115,200). Then activate the automatic port detection by clicking on the PortScanning box {1}. If the interface settings have been entered correctly, the sensor will be detected {6} immediately and its serial number {7} and firmware version {8} displayed. If instead the PortScanning LED {4} is flashing, the PC cannot find the sensor. This can have several causes: 1) No sensor has been connected to the box: Connect a functioning sensor. 2) The programming box has not been switched on or has not been supplied with (sufficient) energy: If the Power LED [7] is not lit, switch on the box or establish a safe energy supply. 3) The connection between the programming box and the PC has not been established: Connect the RS232 cable (correctly). 4) The wrong COM port was selected: Select the correct port in the drop down list of the port selection {2} and plug the RS232 cable into the correct port. You can also perform the troubleshooting during the active PortScanning until the sensor is found. The scanning process can be cancelled at any time by pressing the Stop PortScan button {5}. Instructions for Use Programming Tool SS 20.4xx Page 12
13 6.2 Configuration of the sensor In the sensor configuration area in the left half of the main window, the behaviour of the sensor or of its signal quality {9} and its switching outputs {10} and {11} can be set (see figure opposite). Under the Signal Quality tab {9}, the interval between individual measurements can be changed in millisecond steps by shifting the Sampling Time control. The Average control determines the number of individual measurements used for averaging 3. A higher value produces a smoothing of the signal and a delayed response of the sensor. Signal Quality {9} OC1 {10} OC2 {11} The graph of the signal quality in the subwindow designated "Signal Quality" is not based on the measured values of the sensor, but is only a visual demonstration of how the noise is affected by the averaging. 3 Filtering by sliding arithmetic average. Instructions for Use Programming Tool SS 20.4xx Page 13
14 The switching thresholds of the sensor can be reprogrammed in the same way. On the one hand, the absolute value of the switching threshold can be programmed within the limits of the measuring range. Directly in the section called Change Switching Threshold OCx [mm/s], the threshold value can be typed in directly on the keyboard either in the numeric box or set with the mouse via the control executed as slider. In a unidirectional sensor, the threshold value can only be positive, including the zero. In a bidirectional sensor, the threshold value can also be negative, in which case it will be in the backflow area. The negative absolute value also applies when the analog output of the sensor only outputs the magnitude of the velocity signal and signals the direction via OC1. However, in this case, the output OC1 is fixed to its function as direction indicator and cannot be configured to any desired value as the threshold. Owing to this special feature, the operating software has a special drop down menu in the upper region of the Switching Channel OC1 tab, which allows the switching behaviour of OC1 to be adapted to the zero flow hysteresis of the sensor in the case of direction display (see following figure). OC1 switching profile configuration On the other hand, the switching polarity of both outputs (switches from Low / High to High / Low, when the value ex- Instructions for Use Programming Tool SS 20.4xx Page 14
15 ceeds / drops below High / Low can be changed by pressing the Change OC x Activity button. The set switching profile is shown by way of symbols in the diagram opposite. The following applies to all configurations to be programmed: For values to be programmed, the box (button or control) to be actuated must be released above the box. As long as the sensor is being programmed to the new value or the new configuration (duration about 2-3s), the red Programming LED will be lit and no measured values will be updated by the sensor (see following figure). Programming LED Instructions for Use Programming Tool SS 20.4xx Page 15
16 6.2.1 Response time configuration example Example 1: The sensor is supposed to measure at high dynamics. Whenever the threshold value is exceeded for a short period, this must be signalled by triggering the corresponding switching output and the signal must be active at the analog output. Sampling Time: 1 Average: 0 Example 2: The sensor is supposed to respond quickly, but the analog measuring signal must be as constant as possible so as to be able to absorb extremely quick peaks. Sampling Time: 1 Average: 5 Example 3: The sensor is supposed not to respond at all to short-time variations, the required signal must have maximum constancy. An alarm is not triggered until a safely confirmed value is obtained: Sampling Time: 10 Average: Get sensor default values Default values for all parameters relevant to operation have been stored in the sensor. If wrong settings give undesired results or the sensor no longer responds at all, the operational status of the sensor can in most cases be restored by resetting it to the factory settings. To do so, press the Get Sensor Defaults button {16}. Instructions for Use Programming Tool SS 20.4xx Page 16
17 6.2.3 Diagnostic function In order to be able to determine the cause of a possible sensor fault more easily, the software is equipped with a diagnostic function, which is activated by pressing the Diagnostic button {18}. The software reads out all internal sensor parameters and writes them to a file in the c:\temp\ folder. The name of the file is generated automatically and is made up of the current date and the serial number of the sensor (example: 03_02_2005_SN12345.dat). Please send this file to SCHMIDT Technology GmbH when an error occurs. There the problem can be analysed within a short time and the relevant measures can be initiated. 6.3 Display area The left half of the main window contains various display elements, which can be used to observe the response of the sensor to the set configurations by reproducing and analysing current measurement values. Displays {12} Graph {13} Signal Quality {14} Instructions for Use Programming Tool SS 20.4xx Page 17
18 Upon clicking on the Displays tab {12}, an interface opens containing two analog pointer elements. The top scale containing the blue pointer represents the currently measured flow velocity in real time (taking into account the set response time of the sensor). The bottom scale containing the red pointer indicates the medium temperature measured in the sensor head. The OC1 (Direction) luminous diode indicates the OC1 switching state. Upon clicking on the Graph tab {13}, the flow velocity is shown continuously as a curve display. Upon clicking on the Signal Quality tab {14}, the variations of a constant flow velocity can be detected and displayed via a definable measuring interval. The interval is defined by the number of values to be measured in the # of values box. The scanning of the signal is then started by clicking on the Examine Signal button. The degree of turbulence seen by the sensor is calculated from the average value and the standard deviation of these measured values. The displayed and calculated values are affected by the settings established on the sensor. The measured values are displayed in an automatically scaled histogram. Under laminar flow conditions, a sufficient number of measured values (at least 100) will typically give a Gauss distribution. The values shown under the Signal Quality tab {14] have been calculated only from the signal visible at the sensor and can differ from the real state of the flow. Instructions for Use Programming Tool SS 20.4xx Page 18
19 7 CE Declaration of Conformity Instructions for Use Programming Tool SS 20.4xx Page 19
20 SCHMIDT Technology GmbH Feldbergstrasse 1 D St. Georgen Phone +49 (0)7724/899-0 Fax +49 (0)7724/ info@schmidttechnology.de Part No Instructions for Use Programming Tool SS 20.4xx Page 20
SCHMIDT Sensor interface PROFIBUS Instructions for use
SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...
More informationDATA LOGGER (Version V1.3)
WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:
More informationSIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation
USER MANUAL ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation 2 Index 1. Features and Applications... 3 1.1 Functions of the ADJUSTMENT TOOL... 3 1.2 Dynamic Offset and Amplitude Control
More informationewon Flexy 2 Serial Ports Ext. Card FLA 3301
Installation Guide IG 016 / Rev. 1.2 FLA 3301 This Installation Guide explains how to install the 2 Serial Ports Extension Card FLA 3301. support.ewon.biz Table of Contents 1. Product Summary... 3 2. Safety,
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationMulti-Function Smart Indicator User Manual
Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...
More informationWiFi to RS-232 adapter user manual
WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126
More informationSCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions
SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More informationSeriBox. antrax Datentechnik GmbH
info@antrax.de SeriBox - Interface box with serial or USB interface - PC connection / Read IN and OUT signal information - 3 x INput (TTL level / floating contact) - 3 x OUTput (relay contact) Manual Firmware
More informationFeatures. IDS : Inclinometer Display System with RS232 Output
Graphic Dual Axis Mode Dual Axis Mode Features Single Axis Mode Description Features The IDS is a high quality display system for use with many of our inclinometer sensors. It has a sturdy Aluminium housing
More informationUSER GUIDE. to the CP130. Thermal Printer
USER GUIDE to the CP130 Thermal Printer Revision: 1.0 Filename: CP130 Users Guide v1 0.doc Date: 29 March 2011 1 TABLE OF CONTENTS 1 Table of Contents... 2 2 Introduction... 3 2.1 Notes on Printer Firmware
More informationIPC194. ipconv Protocol Converter
IPC194 General Operating, Maintenance and Installation Manual ipconv Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de Email: info@ipcomm.de
More informationTMC428 Evaluation Kit V2.0 Manual English
TMC428 Evaluation Kit V2.0 Manual English Version: 2.01 July 30 th, 2002 2 TMC428 Evaluation Kit V2.01 Version Version Date Author Remarks 2.00 2002-07-29 OK Created from version 1.02 2.01 2002-07-30 OK
More informationManual Software R-LAS-LT-Scope (LT-Scope) V1.1
Manual Software R-LAS-LT-Scope (LT-Scope) V1.1 (PC software for Microsoft Windows 7, 8, 10) for Laser Reflection Sensor R-LAS-LT-110-HD2 This manual describes the installation process of the software for
More informationIndustrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter
Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de
More informationProTool DriveLine. Software User manual 375/16
ProTool DriveLine Software User manual 375/16 Table of contents 1 General Information... 3 1.1 Documentation...3 1.2 Disclaimer...3 1.3 Trademarks...3 1.4 System requirements...3 2 About ProTool DriveLine...
More informationHardware Manual RM CANview
Hardware Manual RM CANview 1998-2005 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cv_hw_e.doc Table of Contents 1 Legal Regulations...3 2 About the CANview...4 3 Important
More informationMusicTel-Net/Net+ Installation and Operation Manual
MusicTel-Net/Net+ Installation and Operation Manual NOTICE This manual is the MusicTel-Net/Net+ Installation and Operation Manual v2.0. All rights reserved. No part of this document may be reproduced or
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationST-meM-LOG SE. User Manual. Software for Data logger mem-log-se. Version 1.0
ST-meM-LOG SE Software for Data logger mem-log-se User Manual Version 1.0 Contents Contents 1 Overview 5 1.1 Introduction 5 1.2 BMC Messsysteme GmbH 8 1.3 Copyrights 9 1.4 New features of the "Second
More informationDS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM
DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler
More informationMOVIDRIVE Drive Inverters
T MOVIDRIVE Drive Inverters Manual DFC11A CAN us Fieldbus Interface Edition 04/98 10/262/97 C U U 0919 1313 / 0698 Important Notes Important Notes Read this Manual carefully before you start installation
More informationOperating manual. GTL - Configuration tool. Please keep the manual for future use.
Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01 GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33
More informationGeneral Operating, Maintenance and Installation Manual
General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:
More informationSONOFLOW Monitor Short Instructions. For SONOFLOW Sensors of the Series CO.55 V2.0
SONOFLOW Monitor Short Instructions For SONOFLOW Sensors of the Series CO.55 V2.0 Manufacturer: SONOTEC Ultraschallsensorik Halle GmbH Monitor model: SONOFLOW Monitor V02.xx For sensor types: Flow Sensors
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationTechnical Information
Technical Information DATE: January 16, 2014 MODEL: RSP 1570, RSX 1550, RSX 1560 Main Software Upgrade Instructions The RSP-1570, RSX-1550 and RSX-1560 have three separate software modules main software,
More informationE600 VX01 Installation guide
E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing
More informationFail-Safe-Function with Positioner NR-C1
Fail-Safe-Function with Positioner Fail-Safe-Function via Capacitor: The Fail-Safe-Function with Positioner is used to drive a DC- Actuator in case of missing power supply into a choosable final position.
More informationDPM-3221 Digital DC Power Meter with data logging capability.
Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),
More informationCoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...
Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production
More informationBNI IOL K023 BNI IOL K023. User s Guide
BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide Content 1 Notes 2 1.1. Struture of the guide 2 1.2. Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross references 2 1.3. Symbols
More informationInstruction Manual Communication Software PSCS for PS-AMS
Instruction Manual Communication Software PSCS for PS-AMS 2005 PS Automation GmbH BA_AMS_PSCS_0908_E.doc Page 1 Contents: 1. SYSTEM REQUIREMENTS... 3 2. LICENSE AGREEMENT... 3 3. INSTALLATION... 3 3.1.
More informationRP-30 Radar Profiler. Mobile Discharge Measurement System. User Manual. Firmware versions 1.7x and 1.8x. Manual version: V
RP-30 Radar Profiler Firmware versions 1.7x and 1.8x Mobile Discharge Measurement System User Manual Manual version: V02 2014-07-29 Sommer GmbH All rights reserved. The Copyrights for this manual are exclusively
More informationThermal Transient Test Installation and Operating Manual
Thermal Transient Test Installation and Operating Manual 2705A De La Vina Street Santa Barbara, California 93105 Telephone (805) 682-0900 descon@silcom.com www. santabarbaraautomation.com Installation
More informationUSER MANUAL FOR FIOA-0402-U-16
USER MANUAL FOR FIOA-0402-U-16 COPYRIGHT NOTICE This manual is a publication of Renu Electronics Pvt. Ltd. and is provided for use by its customers only. The contents of the manual are copyrighted by Renu
More informationInstallation & Operation Guide
Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This
More informationMagnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual
Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual March 2013 Part Number: 140-10350 R6 Copyright 2013 Magnetek Material Handling 2013 MAGNETEK MATERIAL HANDLING All rights reserved.
More informationSegoSerial Industrial Grade Converter Isolated Dual RS232 - USB. Installation and operation. English Rev. 1.2 Status June I9
SegoSerial Industrial Grade Converter Isolated Dual RS232 - USB Installation and operation www.segosoft.info English Rev. 1.2 Status June 2013 1I9 Contents Introduction... 3 Product features... 3 Description
More informationHardware Manual RM CANview Gateway
Hardware Manual RM CANview Gateway 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc Table Of Contents 1 Legal Regulations... 3 2 About the CANview
More informationOperation Manual GSM modem irz TG42-232
Operation Manual GSM modem irz TG42-232 Table of Contents 1. Introduction... 4 1.1. About this Document... 4 1.2. Service Information... 4 1.3. Safety Precautions... 4 2. Overview... 5 2.1. Purpose...
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationGREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...
E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationFACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM
FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationCA111x-series Arming Station
GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4
More informationLeuze electronic. Dimensioned drawing. Electrical connection. Accessories
2D-code hand-held scanner Dimensioned drawing 4-14 V DC We reserve the right to make changes BP_IT4600_4800_GB.fm Part No. 501 06667! Hand-held scanner for Data-Matrix Codes and Bar Codes! Large reading
More informationHEC. General Operating, Maintenance and Installation Manual
HEC General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet : http://www.ipcomm.de Email: info@ipcomm.de Edition November 2005 Version
More informationReference Guide METTLER TOLEDO WMH Weighing Platforms
Reference Guide METTLER TOLEDO Weighing Platforms Mettler-Toledo GmbH 2005 Doc.No. KA021, 42908713C Weighing Platforms Reference Guide Contents 1 Initial Setup... 4 1.1 Installation... 4 1.2 Electrical
More informationNBF-3. User Manual. NMEA 0183 Buffer. For all variants: NBF-3-BAS, Rev A. Issue 1.01
NBF-3 NMEA 0183 Buffer User Manual For all variants: NBF-3-BAS, Rev A Issue 1.01 NMEA 0183 Buffer - NBF-3 Contents Company Information 4 Important Notices 5 Trademarks and Registered Trademarks 5 Fair
More informationIndustrial PC IPC191C2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter
Industrial PC IPC191C2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de
More informationMagnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual
Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual February 2006 Part Number: 140-10350 Copyright 2006 Magnetek Material Handling 2005 MAGNETEK MATERIAL HANDLING All rights reserved.
More information2DScan TM Barcode Scanner
2DScan TM Barcode Scanner Quick Start Manual Default Check Version FCC WARNING STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
More informationUser s Guide QL-720NW
User s Guide QL-720NW Be sure to read and understand this guide before using the machine. We recommend that you keep this guide nearby for future reference. Not all models are available in all countries.
More informationDPM Digital DC Power Meter with Data logging capability. User Manual
DPM-3232 Digital DC Power Meter with Data logging capability User Manual Introduction As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-60A), Watt, and it also displays
More informationOption Fail-Safe-Accu NRGS1-24VDC incl. positioner
Option Fail-Safe-Accu -24VDC incl. positioner General The electronic AGS-positioner -24VDC is used to control the electric actuator with a continuous current or voltage signal. In case of missing power
More informationLantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED
More informationHybrid AC Driver [GCNC-1110]
Page 1 Installation Manual and Datasheet Page 2 Key Features Smooth and quiet operation at all speeds and extremely low motor heating Industrial grade performance for an alternating current servo motor
More informationBB-303 Manual Baseboard for TMCM-303
BB-303 Manual Baseboard for TMCM-303 Trinamic Motion Control GmbH & Co. KG Sternstraße 67 D 20357 Hamburg, Germany http://www.trinamic.com BB-303 Manual (V1.04 / Jul 9th, 2007) 2 Contents 1 Features...
More informationEPM Programmer EEPM1RA
EP01E - en EN Operating Instructions COPY epm001 EPM Programmer EEPM1RA 2004 Lenze gmbh & C0 KG No part of this documentation may be copied or made available to third parties without the explicit written
More informationEU Driver s Hours Rules covered by Digifobpro. Table of contents
EU Driver s Hours Rules covered by Digifobpro Digifobpro provides analysis of Driver Cards both in it s Quick View and Driver Card - Download features ( see Digifobpro Functions page 4). There follows
More informationF²MC-8L FAMILY MB89201 SERIES FLASH PROGRAMMING 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note
Fujitsu Microelectronics Europe Application Note MCU-AN-300001-E-V10 F²MC-8L FAMILY 8-BIT MICROCONTROLLER MB89201 SERIES FLASH PROGRAMMING APPLICATION NOTE Revision History Revision History Date 2005-02-09
More informationOFP401P0189. Color Sensor. Operating Instructions
OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection
More informationMRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE
General-Purpose AC Servo Servo Configuration Software MODEL MRZJW3- SETUP154E INSTALLATION GUIDE Thank you for choosing the Mitsubishi general-purpose AC servo Servo Configuration Software. To optimize
More informationOPT2011. High-performance distance sensor. Operating Instructions
OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning
More information3001D Smart Safe Manual
3001D Smart Safe Manual For 3001D-1GL/3001D-3GL/3001D-5GL SUMMARY Thank you for using our company s smart safe. Before you use this product, please read this manual carefully, it will help you to use the
More informationAWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009
AWLaunch Software Manual Version 1.2 Last Revised April 27, 2009 All contents in this manual are copyrighted by ArWest Communications. All rights reserved.the information contained herein may not be used,
More informationELAN DIGITAL SYSTEMS LTD. CF428 COMPACT FLASH CF+ CARD USER S GUIDE
ELAN DIGITAL SYSTEMS LTD. LITTLE PARK FARM ROAD, SEGENSWORTH WEST, FAREHAM, HANTS. PO15 5SJ. TEL: (44) (0)1489 579799 FAX: (44) (0)1489 577516 e-mail: support@pccard.co.uk website: http://www.pccard.co.uk
More informationThe accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.
User Manual INTRODUCTION Thank you for choosing our product. The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.
More informationCONFIGURATION HANDBOOK BGL144
PROGRAMMABLE BARGRAPH CONFIGURATION HANDBOOK BGL144 BGL172 LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact : Commercial@Loreme.fr
More informationGSM Unit PU from software version Connecting cable RJ 12/ RJ 12, enclosed
Document number A 30594 00 IT 74 1 CMC-TC GSM Unit DK 7320.820 Important note: For reasons of clarity, these user instructions contain only the most significant details and information and similarly cannot
More informationData editing software EZED3
HL-17149 Data editing software EZED3 OPERATING MANUAL Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety precautions. Please read
More information45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks
45SD Series Bus Expansion Cards For use with Series Photoelectric Sensors on SDS Bus Networks Banner model 45SD plug-in bus cards enable a Banner Series sensor to establish a logical relationship between
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationHD 46 HME 46. Instructions for use
HD 46 HME 46 Instructions for use Safety instructions Please read these instructions carefully and completely before using the headset. Make these instructions easily accessible to all users at all times.
More informationFlex Series User Guide
User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents
More informationBlue Point Engineering
Blue Point Engineering Board - Pro Module (E) Instruction Pointing the Way to Solutions! Controller I Version 2.1 The Board Pro E Module provides the following features: Up to 4 minutes recording time
More informationAM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL
AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3
More informationCopyright. Copyright LogTag Recorders. All rights reserved.
2.0 Copyright The information contained within this document regarding LogTag Analyzer software usage is intended as a guide and does not constitute a declaration of performance. The information contained
More informationitrax Remote Display
itrax Remote Display Customer Product Manual Issued /07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local Nordson representative.
More informationBNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide
BNI IOL302000K006 BNI IOL302000K006C01 BNI IOL302S01K006 BNI IOL302S01K006C01 IOLink 1.1 SensorHub / ActuatorHub User s Guide Content 1 Notes to the user 3 1.1 About this guide 3 1.2 Structure of the guide
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More informationOperating instructions AC010S Compact AS-i E-STOP safety module
Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................
More informationVersion: 16/12/2013. GSV-2MSD-DI Data Logger Instruction manual
Version: 16/12/2013 GSV-2MSD-DI Data Logger Instruction manual Contents GSV-2MSD-DI DMS-Data Logger...4 Connection and commissioning...4 Operating the menu...4 Logger menu...4 Description of the logger
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationTrendSense. Instructions for Use. TrendSense and TrendSense Communicator
Instructions for Use TrendSense and TrendSense Communicator Copyright and contact information Consult Instructions for Use NONIN makes no claim for use of the product other than for those uses specified
More informationIssue 03/2013. The Electronic Load
Issue 03/2013 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model
More informationPC 150. Digital Bench Scale. Operation Manual
PC 150 Digital Bench Scale Operation Manual Revision 1.2 September 14, 2000 1996-2000 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 35 Waltz Drive Wheeling,
More informationPressure-Converter UNICON -P Differential pressure - diminished pressure - overpressure - barometric pressure - flow rate Features
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Pressure-Converter UNICON -P Differential pressure - diminished pressure - overpressure - barometric pressure
More informationCONFIGURATION HANDBOOK
CONVERTER FOR ABSOLUTE SSI ENCODER CONFIGURATION HANDBOOK CNL35 SSI LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact
More informationGSM communicator GD-06 Allegro Complete manual
GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or
More informationOwners Manual i-bdl Battery Data Logger
Owners Manual i-bdl Battery Data Logger Ref : PM-AR-BDL Date Part No : BDL01 (Battery Data Logger 01) Features Suitable for batteries up to 24 V Extremely low operating current Adjustable measuring intervals
More informationMETER Ultrasonic level transmitter
METER Ultrasonic level transmitter 825B105C Technical Data Housing material: Mechanical installation: PBT/PP wetted part 2 GAS M on request PP flange DN50 or DN80 Protection degree: IP65 Electrical connection:
More informationAN-619 APPLICATION NOTE
APPLICATION NOTE One Technology Way P.O. Box 9106 Norwood, MA 02062-9106 Tel : 781/329-4700 Fax: 781/326-8703 www.analog.com Using the ADN8810 Demo Board v2.0 by Troy Murphy and Chris Kung OVERVIEW The
More informationEY-RU : Room operating unit, ecounit
Product data sheet 94.040 EY-RU 341...346: Room operating unit, ecounit341...346 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and
More informationOPERATING MANUAL. WINDOWS Temperature Controller. Digi -Sense
OPERATING MANUAL WINDOWS Temperature Controller Digi -Sense WinTC warranty information and licensing agreement The software and its accompanying documentation and instructions are provided AS IS without
More informationB. Rev. Release Date Description of Change ECR 0A 10/10/2014 Initial Release --- 0B 10/30/2014 Added firmware version to setup menu ---
User s Guide AQ Series Senva Sensors 9290 SW Nimbus Ave Beaverton, OR 97008 154-0011-0B Rev. Release Date Description of Change ECR 0A 10/10/2014 Initial Release --- 0B 10/30/2014 Added firmware version
More informationUSB-to-I2C Basic. Hardware User s Manual.
USB-to-I2C Basic Hardware User s Manual http://www.i2ctools.com/ Information provided in this document is solely for use with the USB-to-I2C product from SB Solutions, Inc. SB Solutions, Inc. reserves
More information