Accessories IC690ACC900
|
|
- Shavonne Craig
- 5 years ago
- Views:
Transcription
1 (IC690ACC900) datasheet Features Provides the IC69* programmable controllers with an interface to devices that use the RS- interface. Allows connection to programming computer without a Work Station Interface board. Easy cable connection to either an IC69, IC69, or IC69 programmable controller. No external power needed - operates from + volt DC power on the programmable controller backplane. Convenient, light weight self-contained unit. Functions The provides an RS- serial interface for the IC69* programmable controllers, which have a built-in RS-/RS- interface. Specifically, it provides a serial connection between an IC69, IC69, or IC69 programmable controller serial port and the serial port on the 6 IC690ACC900 programming computer without the need for a Work Station Interface to be installed in the computer. The programming computer can be an IBM XT, AT, or PS/ or compatible Personal Computer. Location in System The RS-/RS- to RS- converter is a free-standing device which requires two cables as the connections between the programmable controller and the programmer. Its location is limited only by the length of the connecting cables as listed in the interface specifications (see Table ). The cable at the programmable controller end that connects to the RS-/RS- connector on the converter can be up to 0 feet in length (without an external source of + VDC) and up to 000 feet (00m) in length with an external source of + VDC. The cable from the RS- connector on the converter to the programming computer s serial port can be up to 0 feet (m) in length. FRONT VIEW REAR VIEW a69 IC690ACC900A CABLE ADAPTER MADE IN USA IBM and PS/ are registered trademarks of International Business Machines Corporation.
2 Installation Installation of the consists of connecting two cables. Select the proper cables for your installation. Prewired cables (see below) are available, or if cables of different lengths are required by your application, you can build your own cables. Specifications for building these cables are provided later. You do not need to connect an external source of power to the converter for a cable length of 0 feet, or less, since the necessary power connections of + VDC and signal ground are derived from the programmable controller s backplane bus through the cable which connects to the IC69, IC69, or IC69 programmable controller. Select one of the three RS- compatible cables (0 feet in length) that will connect the programmer s (or other serial device) RS- serial port to the RS- port on the converter. The catalog numbers of these cables are: IC690CBL0 (use with the IC60 industrial computer, or IBM PC-XT or compatible personal computer), IC690CBL0 (use with IBM PC-AT or compatible personal computer), and IC690CBL0 (use with the IC6 industrial computer, or IBM PS/ or compatible personal computer). A standard 6-foot cable (HHP compatible) is available to connect the RS-/RS- port on the converter to the RS- port on the programmable controller. The catalog number of this cable is IC69CBL0. Installation of these cables should be done with the programmable controller powered-down. Connect the -pin male connector on the 0 foot cable to the -pin female connector on the converter. Connect the female connector (9-pin or -pin) on the opposite end of this cable to the male RS- connector (serial port) on the selected programming (or other serial) device. If you build you own cable, use a connector that is compatible with your serial device. Notice that both ends of the 6-foot RS-/RS- compatible cable are the same; a -pin male connector is attached at both ends. Connect one end of this cable to the -pin female connector on the RS-/RS- connector on the converter. Connect the other end of this cable to the -pin female connector, which interfaces to the RS- compatible serial port on the IC69* programmable controller. For the IC69 programmable controller, this connector is accessed by opening the hinged door on the power supply. The serial port connector for the IC69 programmable controller is on the CPU module, and is accessed by opening the hinged door on the module. The serial port for the IC69 programmable controller is located on the CPU module. Cable Description The serial connection to the IC69 programmable controller (see Figure ) is to the RS-/RS- compatible serial port connector, located at the bottom of the CPU module behind the hinged door, through an available 6 foot ( meter) serial interface cable - IC69CBL0. Wiring information and recommended cable and connectors are provided for those who may want to build their own cable having a different length. The serial connection to the IC69 programmable controller is to the RS-/ compatible serial port connector located behind the hinged door on the right front of the power supply, also through the same 6 foot serial interface cable, IC69CBL0 - or equivalent, as shown in Figure. The serial connection to the IC69 programmable controller (see Figure ) is to the RS-/RS- compatible serial port connector, located on the lower right of the CPU module, also through the available 6 foot ( meter) serial interface cable - IC69CBL0.
3 C P U PROGRAMMABLE CONTROLLER RS- RS- PROGRAMMER a69 Figure. Typical Configuration with an IC69 Programmable Controller PROGRAMMABLE CONTROLLER RS- RS- PROGRAMMER a6 Figure. Typical Configuration with an IC69 Programmable Controller PROGRAMMER RS- a0 PROGRAMMABLE CONTROLLER RS- Figure. Typical Configuration with an IC69 Programmable Controller RS- Interface Pin Assignments Pin assignments and signal definitions for the RS- interface are given in the table below. Pin Table. RS- Interface for Converter Signal Name Function I/O Shield Cable shield - SD Transmitted Data Out Received Data In RTS Request to Send Out Clear to Send In 6 - No connection - SG Signal Ground - Data Carrier Detect In No connection - 0 Data Terminal Ready Out - - No connection - RS-/RS- Interface Pin Assignments Pin assignments and signal definitions for the RS- interface are given in the table below. Pin Table. RS-/RS- Interface for Converter Signal Name Function I/O Shield Cable shield (A) Differential Data Carrier Detect Out (B) Differential Data Carrier Detect Out ATCH/ Attach (used with HHP) n/a + VDC Logic Power In 6 RTS(A) Differential Request To Send Out SG Signal Ground, 0V In (B ) Differential Clear To Send In 9 RT Resistor Terminator n/a 0 (A ) Differential Receive Data In (B ) Differential Receive Data In SD(A) Differential Send Data Out SD(B) Differential Send Data Out RTS(B) Differential Request To Send Out (A ) Differential Clear To Send In
4 Logic Diagram The following figure is a logic diagram of the. RS- - SHIELD RS-/RS- (IC690ACC900) a9 RS-/RS- - SHIELD 9 TERMINATOR RESISTOR 0 Ω ( B ) SD 0 ( A ) SD (B ) SD (A ) RTS MODEM ( B ) ( A ) RTS ( B ) 6 RTS ( A ) ( B ) ( A ) LOGIC POWER + SG NC SG 0 ATTACH ATCH/ Figure. Logic Diagram
5 Jumper Configuration There are three jumper locations on the converter board for selection of user options. Each jumper position has three pins, as shown in the following illustration. These jumper positions, labeled JP, JP, and JP, are accessed by removing the square plastic cover on the top of the converter. Configuration can be changed as required by carefully removing one or more of the jumpers with a pair of needle nose pliers RS-/RS and placing it on the desired pair of pins. Refer to the description of these selectable jumper positions in the following table and place the jumper on the selected pair of pins. The pins are numbered,, and. As shown in Figure and Table, the default jumper locations are indicated by a rectangle over the pins to be jumpered for each position. The default pin numbers are and. a60 RS- Figure. Location of Jumpers for User Options Table. Jumper Configuration for Jumper Position Label Jumper Configuration Description JP Default position and is used when the device communicating with the PLC does not supply the Carrier Detect signal. JP forces the signal active on the RS- port. Use jumper positions and if the device does supply the Carrier Detect signal. This allows the programming device to control. JP MODEM Default position and is used when an attached Modem does not require the Clear To Send () signal. This allows the programming device to control the RTS signal. Jumper positions and are used when the attached Modem does require the signal (most modems require this signal). Forces RTS to be continually active. JP ATTACH Default position and is used for most applications communicating with the PLC via a serial programming port. Jumper positions and are used if the device communicating with the PLC is intended to emulate the Hand-Held Programmer protocol. Refer to the documentation for your serial device for signal requirements.
6 6 Example of Cable Connections The following figure is an example of the wiring connections for the cables required in a typical PLC system using the RS-/RS- to RS- converter. HOST COMPUTER TD RTS GND RS- SHIELDED PAIRS 0 SD RTS GND SHLD - RS-/RS- (IC690ACC900) - FE RS- - FE RS- (A) (B) (A ) (B ) SD (A) SD (B) RT (A ) (B ) RTS (A) RTS (B) +V 0V SHLD * POWER SOURCE FOR POINT-TO-POINT CONNECTION 0 FEET ( METERS) ONLY. POWER SOURCE BEYOND 0 FEET ( METERS) AND FOR MULTIDROP CONNECTION MUST BE EXTERNAL SOURCE. ** TERMINATION RESISTANCE FOR THE RECEIVE DATA () SIGNAL NEEDS TO BE CONNECTED ONLY ON UNITS AT THE END OF THE LINES. THIS TERMINATION IS MADE ON THE IC69 PLC PRODU BY CONNECTING A JUMPER BETWEEN 9 AND 0 INSIDE THE - D-SHELL WITH THE FOLLOWING EXCEPTION. FOR IC69 PLCS, CATALOG NUMBERS IC69CPU AND IC69CPU, THE TERMINATION FOR AT THE PLC IS IMPLEMENTED BY A JUMPER BETWEEN 9 AND RS- TWISTED SHIELDED PAIRS Figure 6. Example of Cable Wiring Connections to Converter Multidrop Configuration The following figure is an example of using the converter in a multidrop configuration. SD (A) SD (B) 0 (A ) (B ) ** 9 RT 6 RTS (A) RTS (B) (A ) (B ) * +V * 0V SHLD - a0 IC69 PLC RS- - FE * PROGRAMMER RS- - IC690CBL0 OR EQUIVALENT RS- SHIELDED PAIRS TD RTS GND - FE RS-/RS- (IC690ACC900) NOTE WHEN WIRING RS- / MULTIDROP CABLES REFLECTIONS ON THE TRANSMISSION LINE CAN BE REDUCED BY CONFIGURING THE CABLE IN A DAISY CHAIN FASHION AS SHOWN BELOW. MASTER SLAVE STATION LAST STATION 0 - FE RS- - FE RS- ALSO IT IS RECOMMENDED TO MAKE ANY NECESSARY CONNECTIONS INSIDE THE CABLE CONNECTOR TO BE MOUNTED ON THE PLC. IT IS NOT RECOMMENDED TO USE TERMINAL STRIPS OR OTHER TYPES OF CONNECTORS ALONG THE LENGTH OF THE TRANSMISSION LINE. 0 TD GND SHLD - (A) (B) (A ) (B ) SD (A) SD (B) RT (A ) (B ) RTS (A) RTS (B) +V POWER SOURCE FOR PLC - CONNECTOR FOR IC69 PLC; LOCATED ON POWER SUPPLY FOR IC69 PLC: LOCATED ON CPU BOA TERMINATION RESISTANCE FOR THE RECEIVE DATA () SIGNAL NEEDS TO BE CONNECTED ONLY ON UNITS AT THE END OF THE LINES. THIS TERMINATION IS MADE ON THE IC69 PLC PRODU BY CONNECTING A JUMPER BETWEEN 9 AND 0 INSIDE THE - D-SHELL WITH THE FOLLOWING EXCEPTION. FOR IC69 PLCs, CATALOG NUMBERS IC69CPU AND IC69CPU, THE TERMINATION FOR AT THE PLC IS IMPLEMENTED BY A JUMPER BETWEEN 9 AND. GROUND POTENTIAL: MULTIPLE UNITS, NOT CONNECTED TO THE SAME POWER SOURCE, MUST HAVE COMMON GROUND POTENTIALS OR GROUND ISOLATION FOR PROPER OPERATION OF THIS SYSTEM. 0V SHLD V 0V RS- MAKE CONNECTIONS INSIDE D-CONNECTORS TO OTHER PLC s Figure. Example of Multidrop Configuration with Converter * * SD (A) SD (B) 0 (A ) (B ) 9 RT 6 RTS (A) RTS (B) (A ) (B ) +V 0V SHLD - SD (A) SD (B) 0 (A ) (B ) 9 RT 6 RTS (A) RTS (B) (A ) (B ) +V 0V SHLD - a SLAVE STATION IC69 PLC CPU RS- - FE LAST STATION IC69 PLC PS RS- - FE
7 Power Requirements Table. Specifications for IC690ACC900 * Voltage + volts DC, +% Current 0 ma, ±% RS-/RS- Interface Cable Maximum Cable Length Cable Lengths: 000 feet (00 meters) Cable Type: 6 feet ( meters) Belden 90, AWG # (0.mm ) wire 0 feet (0 meters) Belden 909, AWG # (0.6 mm ) wire } 0 feet (0 meters), up to 000 feet (00 meters) Same cable as for 0 feet (0 meters) Connector Type RS- Interface Cable Maximum cable length Up to 0 feet ( meters) Connector Type -pin D-type Male Subminiature (programming device end) 0 feet ( meters) Converter end: -pin D-type Female Subminiature Programming device end: 9-pin, -pin, or -pin (depending on type of connector on your serial device) D-type Female Subminiature Catalog numbers are provided as suggestions only. Any cable having the same electrical characteristics is acceptable. It is strongly recommended that you use stranded wire. Since it is sometimes hard to find a cable with the desired number of twisted pairs (the Belden 909 has an extra pair), you may end up with a cable with extra pairs. For distances over 0 feet ( meters), the + volt DC logic power source must be provided externally by connecting an external power supply to the +V and SG (0V) connections at the converter end of the cable. The +V pin at the PLC connector end of the cable must not be connected to the cable. The +V and SG connections from the external power supply must be isolated from its own power line ground connection. Ensure that there is no connection between the external supply and the PLC except the SG cable connection. * Refer to GFK-06B, or later for product standards and general specifications. Table. Ordering Information Description Converter, RS-/RS- to RS- Catalog Number IC690ACC900
8
Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation
July 2000 RS-4 Port Isolator IC0ACC03 The IC0ACC03 RS-4 Port Isolator replaces the obsolete ICCMM0 Isolated Repeater/Converter (also known as the Brick ). This Port Isolator provides the basic functionality
More informationThis Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.
This Datasheet is for the IC6CBL00 I/O Bus Expansion Cables http://www.qualitrol.com/shop/p-45-ic6cbl00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 0-0 module. For
More informationIntegrity Instruments
Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485-25A High Speed RTS Enabled RS-232
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More information1. FEATURES AND BENEFITS
Series S i x Programmable Controller GFK-0238A Communications Control Module Type 2 and Type 3 November 1988 IC600CB536 IC600CB537 General Description The Communications Control Module Type 2 (CCM2) and
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationSeries Specialty PLCs
Series 90-70 Programmable Controllers Series 90-70 Specialty PLCs Utilizing field-proven Series 90-70 PLC, Genius I/O, and VersaMax I/O products, GMR (Genius Modular Redundancy) system is a modular redundancy
More informationInstalling the Panel. Installing the Panel
7 In this section you will be given all of the information you need to install the panel. Before actually installing the OP- panel, it may be helpful to examine the specifications and make sure that the
More informationIC693PWR331 High Capacity Power Supply, 24 VDC Input
IC693PWR331 High Capacity Power Supply, 24 VDC Input The Series 90-30 DC input High Capacity power supply (IC693PWR33) is a 30 watt wide range supply designed for 24 VDC nominal inputs. For applications
More informationThis Datasheet is for the IC693PWR332. High Capacity Power Supply, 12 VDC Input.
This Datasheet is for the IC693PWR332 High Capacity Power Supply, 12 VDC Input http://www.qualitrol.com/shop/p-14698-ic693pwr332.aspx Provides the wiring diagrams and installation guidelines for this GE
More informationWeight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1
8 Panel Specifications: In this section, you will be given all of the information you need to install the panel. Before actually installing the OP-9001 panel, it may be helpful to examine the specifications
More informationThis Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.
This Datasheet for the IC697BM733 Series 90-70 Genius. http://www.cimtecautomation.com/parts/p-14756-ic697bem733.aspx Provides the wiring diagrams and installation guidelines for this G Series 90-30 module.
More informationAppendix G. CJ1W-CIF11 RS-422A Converter
CJ1W-CIF11 RS-422A Converter The CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C port and converts RS- 232C to RS-422A/485. Specifications General Specifications Item Specification
More informationInstallation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.
IBSS Manual IBSS Installation and Programming Manual This Manual describes the IBSS InterBus-S Slave, its uses and set up. Effective: 03 June, 1996 Niobrara Research & Development Corporation P.O. Box
More informationABB Drives. User s Manual RS-485 Adapter Board FRSA-00
ABB Drives User s Manual RS-485 Adapter Board FRSA-00 Table of Contents 1 INTRODUCTION... 2 1.1 Overview... 2 1.2 Technical Data of RS-485 Link... 2 1.3 RS-485 Bus Topology... 2 2 INSTALLATION... 2 2.1
More informationGE Fanuc IC694BEM331 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694bem331 Rx3i PacSystem RX3i Genius Bus Controller (supports I/O and Datagrams). IC694B IC694BE IC694BEM 919-535-3180
More informationCS485. User s Manual. Version ZYPEX, Inc.
CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationBus Transmitter Expansion Module (Fiber Media) with built-in switch. PROFINET Slave, Version 2.2 Class A IO-Device
Remote I/O Units A Remote I/O Unit connects modules to a host PLC or computer via a variety of networks. This makes it easy to include in the innovative PROFINET interface, as well as Genius, Profibus-DP,
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationOverview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus
user s guide DIN - RS232 user s manual 2 Overview The DIN-RS232 is a DIN rail mount breakout for SmartMotor RS-232 communications. It allows a single master to communicate with up to eight SmartMotors
More informationCPU Module IC200CPU005
Product Revision History PWR OK RUN FAULT FORCE PORT PORT RS232 RS48 Features Supports up to 64 modules with up to 2048 I/O points Can be either autoconfigured or configured from a programmer using configuration
More informationMODEL DRIVER Ic Ip VDC
Provides Mounting & Connections for Stepnet Module CANopen Stepping Driver FEATURES Develop & Debug Stepnet projects then transfer design to OEM pc board. MODEL DRIVER Ic Ip VDC -075-01 STM-075-07 5 7
More informationThis Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.
This Datasheet for the IC670MDL640 24VDC Pos/Neg Logic Input 6 Pt. Grouped http://www.cimtecautomation.com/parts/p-4-ic670mdl640.aspx Provides the wiring diagrams and installation guidelines for this GE
More informationVersaMax* Serial Communications Module
Product The VersaMax Serial Communications Module, IC200CMM020, operates as a Modbus RTU Master in a VersaMax I/O Station controlled by a Genius Network Interface Unit or a PROFINET Scanner. Revision Firmware
More information1 1 Getting Started $ "% # + %#! & %! + % $!% +!% $% # * %&# $ +!% ' *!# * %&# $ + $$ %!% "&% &%"&% # $$ $ +!( % " % $!%! %$ + $) % "$!# %% "!
2 Manual Introduction The Purpose of this Manual This manual shows you how to install, program, and maintain the equipment. It also helps you understand the system operation characteristics. Who Should
More informationEasyCoder 501/601 Installation Instructions
RS 422/485 INTERFACE KIT Introduction Note: Illustrations show an EasyCoder 501. The principles for fitting this optional equipment in an EasyCoder 601 are exactly the same. The RS 422/485 Interface Board
More informationME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.
ME778C-RJ45 Line: RJ-45 MAIN MODULE Mini Driver MP Card ME778C-RJ45 Power Line: RJ-45 Unit A -TD -RD -CD -TD Serial: 10-Pin RJ INTERFACE MODULE (REAR CARD) Unit B -RD -CD Serial: 10-Pin RJ LO Z A HI Z
More informationThis Datasheet is for the IC693MDL /24 Volt DC, 0.5A Positive Logic Output, 32 Point.
This Datasheet is for the IC693MDL753 12/24 Volt DC, 0.5A Positive Logic Output, 32 Point http://www.qualitrol.com/shop/p-14675-ic693mdl753.aspx Provides the wiring diagrams and installation guidelines
More informationCPU Modules CPU001 and CPU002
PWR OK RUN FAULT FORCE PORT PORT RS232 RS48 Features Non-volatile flash memory for program storage Programming in Ladder Diagram and Instruction List Battery backup for program, data, and time of day clock
More informationAnalog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules
Analog Input Modules Analog Current Input - 16 Channel IC693ALG223 The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each capable of converting an analog input signal
More informationIntroduction. General Ratings
Introduction Storage temperature Operating temperature Humidity Weight Dimensions Screw terminal wire gauge Supply voltage Supply currents Maximum baud rate Unit Mounting Housing o -20 to +70 C o Allows
More informationBuilding the Communication Cable
uilding the Communication Cable 99 uilding the Communication Cable There are several considerations that help determine the type of cable needed for your application. 1. Will the be physically connected
More informationRemote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication
Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those
More informationSerial Communication Converters & Adapters Instruction Manual
Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to
More informationCPU Module IC200CPU005
December 0 GFK-0J PWR PORT PORT RS RS Features Supports up to 6 modules with up to 0 I/O points Can be either autoconfigured or configured from a programmer using configuration software KB of configurable
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationInstallation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting
Installation Manual PTZ camera controller unit DIN-rail mounting CIB-tech I n t r o d u c t i o n The is a PTZ (Pan Tilt Zoom) video camera control unit, part of the CIB-tech automation system. The can
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationData Sheet Rev DALLIS Serial Data
Lawo AG, Germany Phone: +9 00-0 Web: www.lawo.de Data Sheet Rev. 00-0-0 DALLIS Serial Data Port serial multi-format data converter 9/ Serial Data bidirectional data Ports, data rates up to 00 bps Supports
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationVersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.
April 2012 The VersaMax * IC200BEM003 PROFIBUS Master Module allows a VersaMax CPU005, CPUE05 or PROFINET Scanner (PNS) to send and receive data on a PROFIBUS-DP V1 network. The PROFIBUS Master module
More informationGE Fanuc IC694ALG221. Rx3i PacSystem
GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com
More informationThis Datasheet for the IC697CMM711. Communications Coprocessor, CMM, RTU, SNP, and SNPx Protocols
This Datasheet for the IC69C11 Communications Coprocessor, C, RTU, SNP, and SNPx Protocols http://www.cimtecautomation.com/parts/p-144-ic69cmm11.aspx Provides the wiring diagrams and installation guidelines
More informationMoxa TCC-100 Series User s Guide
Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The
More informationMoxa TCC-100 Series Hardware Installation Guide
Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide
More informationThis Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.
This Datasheet for the IC670ALG310 Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V http://www.qualitrol.com/shop/p-14493-ic670alg310.aspx Provides the wiring diagrams and installation guidelines for
More informationUSER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters
USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationDNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison
DNETEXT-C CAN Bus Extender, Version 3 User s Manual Brad Harrison Although every effort has been made to insure the accuracy of this document, all information is subject to change without notice. Woodhead
More informationModel User Manual Revision E 04/29/99. OEM Gaging System. Part Number R01
04/29/99 Model 3800 OEM Gaging System User Manual Revision E Part Number 028585-R01 Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted
More informationDIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL
DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL REVISED: 8/12/13 DGH CORPORATION PO BOX 5638 MANCHESTER, NH 03108 TELEPHONE: 603-622-0452 FAX: 603-622-0487 WEB: www.dghcorp.com The information
More information205 CPU NETWORK ADAPTER F2-UNICON
205 CPU NEWORK ADAPER F2-UNICON Network Adapter he F2-UNICON Network Adapter is used to place Automationdirect.com DL205 CPUs (except D2-230 and D2-250) on a RS-422 or RS-485 multi-drop network. he Network
More informationDiscrete Input Modules IC697MDL653
43 1 I97MDL653 24 Volt Positive/Negative Logic, 32-Point Input Module 24 Volt Positive/Negative Logic, 32-Point Input Module (I97MDL653) datasheet Features a44082 32 Points - Four isolated groups of 8
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationSummary. Introduction
A 2 B - I 2 S MODULE - MODULE EVM SYSTEM A 2 B - I 2 S MODULE Summary SUPPORTS ANALOG DEVICES Off the shelf module for A 2 B interfacing to I 2 S and I 2 C devices Based on Analog Devices newest AD2428W
More informationInstallation Guide Serial Interface T942SI
Installation Guide 2003-02-8/ Ver. C Contents.... General... 2 Board Description... 2 3 Installation... 4 3. Mounting... 4 3.2 Opening the Housing... 4 3.3 Mounting together with other Units... 5 3.4 Wiring
More informationClassic Brain Boards. Classic Brain Boards. Features. Description. Networking. Part Numbers
B2 Analog Brain Board Features Intelligent digital processors. Serial data link operates at selectable baud rates from 300 baud to 38.4 Kbaud Optomux units can be configured for either multidrop or repeat
More informationFrame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.
A P P E N D I X B Cabling Summary Introduction This appendix contains details on the MGX 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction
More informationGE Fanuc IC694ALG391. Rx3i PacSystem
GE Fanuc IC694ALG391 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg391 Rx3i PacSystem Output module analog 2 points, current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com
More informationADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual
ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following
More informationGE Fanuc Automation Programmable Control Products. PACSystems RX3i. Serial Communications Modules. User s Manual, GFK-2460A.
GE Fanuc Automation Programmable Control Products PACSystems RX3i Serial Communications Modules User s Manual, GFK-2460A March 2007 Warnings, Cautions, and Notes as Used in this Publication GFL-002 Warning
More informationDiscrete Output Modules IC697MDL750
54 IC697MDL750 (IC697MDL750) datasheet Features 32 Points - Four isolated groups of 8 points each a44709 0.5 amp capacity per point High inrush capacity (20x rated current) Functions The 24/48 Volt DC
More informationInstalling the DX LCD Display
DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and
More informationMEV Limited USB232/485 INSTRUCTION MANUAL
MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual
More informationThis Datasheet for the IC697BEM721. I/O Link Interface Module for the Series
This Datasheet for the for the Series 90-70. http://www.cimtecautomation.com/parts/p-14754-ic697bem721.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-30 module. For
More informationDiscrete Output Modules IC697MDL740
55 1 IC697MDL740 (IC697MDL740) datasheet Features 16 Points - Four isolated groups of 4 points each 2 amp capacity per point High inrush capacity (10x rated current) Functions The 24/48 Volt DC 2 Amp Output
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More informationDefining the Future in Motion Control
Defining the Future in Motion Control USER S MANUAL 1 DINIO7 user s manual Overview The DINIO7 is a DIN-rail mounted peripheral for the SmartMotor versions 3 and 4 product lines Hereafter, the SmartMotor
More informationAutomationdirect.com. D i r e c t L o g i c M O D B U S S L A V E F 4 S L V - M B
Automationdirect.com D i r e c t L o g i c 4 0 5 M O D B U S S L A V E F 4 S L V - M B Order Number: F4-SLVMB-M Automationdirect.com is a Trademark of Automationdirect.com Modbus is a Trademark of Gould
More informationProduct Information. Firmware Version 3.10 Programmer Compatibility Expansion I/O Compatibility
Important Product Information January 2016 VersaMax* CPU with Embedded Ethernet Interface CPUE05 PWR OK RUN FAULT FORCE PORT 2 RS232 MAC XXXXXXXXXXXX IP ADDRESS shares the basic features of the other VersaMax
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationPmod modules are powered by the host via the interface s power and ground pins.
1300 Henley Court Pullman, WA 99163 509.334.6306 www.store. digilent.com Digilent Pmod Interface Specification 1.2.0 Revised October 5, 2017 1 Introduction The Digilent Pmod interface is used to connect
More informationes Six programmable controller and Input/Output Communications Control Module (I/O CCM) IC600BF948 General Description GEK-90824D July 1989
Programmable es Six Controllers July 1989 Input/Output Communications Control Module (I/O CCM) IC600BF948 General Description The Input/Output Communications Control Module (I/O CCM) provides a serial
More informationFEATURES DESCRIPTION MODEL 110B. Power Supply
FEATURES Extends wiring distance of FT-10 LonWorks Networks. (2) channels using a single Model 110B. Up to 10 channels using (5) Model 110B. Low cost alternative to routers configured as repeaters. Wring
More informationintan intan RHD2000 Dual Headstage Adapter RHD2000 Dual Headstage Adapter Features Applications Description TECHNOLOGIES, LLC
RHD2000 Dual Headstage Adapter 20 September 2016 Features Allows two RHD2000 amplifier boards to share a single SPI interface cable Compatible with any Intan Technologies amplifier boards in the RHD2000
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationUSB/RS232 TO cctalk COMMUNICATION BOARD Technical Information
USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information USB/RS232 to CcTalk COMMUNICATION BOARD 18/04/2016 Manual code: 81043530 ATTENTION: Read this technical manual carefully before installing
More informationThis Datasheet for the IC697CMM741. Series MMS or TCP/IP Ethernet LAN Interface.
This Datasheet for the IC697CMM741 Series 90-70 MMS or TCP/IP Ethernet LAN Interface. http://www.qualitrol.com/shop/p-14776-ic697cmm741.aspx Provides the wiring diagrams and installation guidelines for
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationMiniature Asynchronous 4-Wire High Speed Modems
ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
More informationVorne Industries. 87/708 Master Clock Display User's Manual
Vorne Industries 87/708 Master Clock Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 www.vorne.com Chapter 1 Setting Up Your Display For Operation...
More informationDiscrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module
March 2002 Discrete Output Modules IC697MDL750 24/48 Volt DC, 0.5 Amp, 32 Point Output Module Features 32 Points - Four isolated groups of eight points each 0.5 amp capacity per point High inrush capacity
More informationVersaMax IP. Proficy Machine Edition. Publication Reference Chart
Distributed I/O is designed to offer the ruggedness and reliability of a standard I/O system installed in a NEMA 4 cabinet, without the cost and effort to build the cabinet. is IP67 rated so it can be
More informationPackage Contents. GP Options (Made by Digital)
When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationMini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP
MAY 1997 ME745A-F-R2 ME745A-M-R2 ( Driver MP with 5-Screw Terminal Block) MINI DRIVER MP CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
More informationINTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description
INTERFACES DATA SHEET page 1/6 Part Number Description AC24AT ISA Bus Serial Port RS422/485, Isolated Description The AC24AT is an RS-422/485 adapter card that plugs directly into the IBM PC bus and provides
More informationGE Fanuc IC695CMM004. Rx3i PacSystem
GE Fanuc IC695CMM004 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695cmm004 Rx3i PacSystem RX3i serial communications module. Four isolated RS-232/485 port. IC695C IC695CM IC695CMM 919-535-3180
More informationCPU Modules CPU001 and CPU002
CPU Modules CPU00 and CPU00 GFK-6V PWR PORT PORT RS RS Features Non-volatile flash memory for program storage Programming in Ladder Diagram and Instruction List Battery backup for program, data, and time
More informationHow to wire DMX/RDM lighting systems
Application note How to wire DMX/RDM lighting systems DMX/RDM is a robust and reliable system for lighting control. However, if not implemented correctly, problems can arise such as random flashing of
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationTB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.
NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe
More informationProduct Information. Firmware Version 3.00 Programmer Compatibility Expansion I/O Compatibility
Important Product Information August 2015 VersaMax* CPU with Embedded Ethernet Interface CPUE05 PWR OK RUN FAULT FORCE PORT 2 RS232 MAC XXXXXXXXXXXX IP ADDRESS shares the basic features of the other VersaMax
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More information