Product Catalog Special Purpose Fuses. Circuit Protection
|
|
- Paula Johnston
- 5 years ago
- Views:
Transcription
1 Product Catalog Circuit Protection
2 Table of Contents General Catalog Contents Page Cable Limiters UCL/UCL/UCLC Capacitor Fuse, Non-Time-Delay CCL/CCLW Lift Truck Fu CK/CL/LS Limiters NL Non-Time-Delay NN Very Fast-cting High Spd Fu, 30V - E3S V - E5SF/E5S V- E25SFX/E25S V - E50SF/E50S V - E60C V - E60SF/E60S V - E70SF/E70S V - ESF/ES ritish Style Trip Indicators Microswitch dapter MI Type D ottle Fu Neozed Fu NH Fu i
3 Copper Cable Limiters (600Vac) Copper/luminum Cable Limiters (250Vac) Circuit Protection Catalog Number UCL (25XX 75XX) 600Vac or Less Catalog Number UCL 250Vac or Less Catalog C Volts Copper Number* Rating Cable Size Cable Terminals vailable UCL25XX () MCM T = Copper crimp tube UCL35XX () MCM O = olt-on blade offset from center UCL50XX () MCM = olt-on blade, centered UCL75XX () MCM UCL 250 2/0 or 3/0 (2) olt-on blade, one end offset from center *Contact Edison Customer Satisfaction for availability, limiters not shown, latest data or information. () Choose terminals from "Cable Terminals vailable" column to complete catalog number, EXMPLE: "UCL-25TO" is rated for a "25" 250MCM copper cable and has a "T" tube for crimping and an "O" bolt-on blade, offset from center. ny combination of the thr terminals may be selected. (2) 4/0 aluminum cable may be used with a copper blade-to-aluminum cable connector. enefits: Cable limiters help to a maintain electrical service by minimizing cable damage due to short circuit currents. Isolates faulted cable(s) in multiple cables per phase installations. Several cable termination types available. s: Residential: 250Vac limiters can be used to protect individual service cables tapped from a single transformer. Non-Residential: 600Vac cable limiters should be specified to protect parallel service cables in 20/208Vac, 277/480Vac etc. systems. Cable Limiter Specifications Voltage Rating: Cable Ratings: Interrupting Rating: gency pprovals: Self-certified to UL requirements. UCL25XX 75XX, 600Vac UCL, 250Vac 250MCM to 750MCM Cu - 600Vac 2/0 or 3/0 Cu - 250Vac 4/0 l - 250Vac (Cu/l terminal required) 600V - 200,000 mps RMS 250V -,000 mps RMS 49
4 Copper Cable Limiters (600Vac) Copper/luminum Cable Limiters (250Vac) of Cable Limiters: y industry definition, cable limiters do not provide overload protection. Class J and Class L fu for thr or more cables-per-phase applications should be considered if overload protection is a concern. This may also be a desirable consideration for aluminum cable using suitable connectors. Cable limiters applied in utility networks and building power system main parallel service cables are primarily intended to isolate faults in multiple-cables-per-phase installations. This prevents total power outages until maintenance of faulted cable(s) can be scheduled. During the process of opening under fault conditions to isolate faulted cable(s), limiters current limiting action reduces potential for excess heat damage to unfaulted cables. Dimensions - inches Cable Limiters 250 Volts or Less C For applications having thr or more parallel cablesper-phase, cable limiters are installed at each end of each cable. For nonparallel or multiple radial cables, limiters may successfully be applied at the source end of each cable for fault isolation. When analyzing cable limiter potential applications, it is not unusual to forget that normal and abnormal current through cable limiters is divided just as it is betwn cables. Selectivity with upstream overcurrent protection devices is seldom of concern. When designing for cable limiter fault isolation to prevent a burn down or unscheduled blackout by one faulted cable, it is desirable to determine the continuous rating load (3 hours or more) that the remaining cables must handle without overheating. Cat. No. UCL 50
5 Copper Cable Limiters (600Vac) Copper/luminum Cable Limiters (250Vac) Cable Limiters 600 Volts or Less C Circuit Protection Dimensions are shown in inches.* Tube-Offset lade (TO)** Copper Catalog Cable Number Size* C D E F G H J UCL25TO 250 MCM -7/8-7/6 3/4 9/32 3/32 -/8 UCL35TO 350 MCM 2 3-5/8 3-3/8-5/8 7/8 45/64 -/6 /4 UCL50TO 500 MCM 2-7/8-7/8 -/6 53/64-3/6-5/8 UCL75TO 750 MCM 3-/2 3-3/4 3-/2 2-/2-5/6 -/6 -/2 2 Center lade-offset lade (O)** Copper Catalog Cable Number Size* C D E F G UCL25O 250 MCM -7/6 3/32 -/8 -/8 UCL35O 350 MCM 3-3/8 3-5/8-5/8 -/6 /4 UCL50O 500 MCM -7/8 -/2-5/8-3/6 UCL75O 750 MCM 3-/2 3-3/4 2-/ /2 Tube-Tube (TT) E C D Copper Catalog Cable Number Size* C D E UCL25TT 250 MCM -7/8-7/6 3/4 9/32 UCL35TT 350 MCM 2 3-5/8-5/8 7/8 45/64 UCL50TT 500 MCM 2-7/8-7/8 -/6 53/64 UCL75TT 750 MCM 3-/2 2-7/8 2-/2-5/6 -/6 *Limiter terminals are silver plated copper. **Dimensions of "TT", "OO", "T", etc., terminals are determined by matching appropriate dimensions shown. 5
6 Copper Cable Limiters (600Vac) Copper/luminum Cable Limiters (250Vac) verage Time-Current Curve Cat. No. UCL-(XXXX)-600Vac 52
7 Co e Cable te s a Co e l n Cable te s a verage Time-Current Curve TIME IN SECONDS. UCLC ND UCL MP RTING Circuit Protection Peak Let-Through Current Curve Cat. No. UCL and 250V INSTNTNEOUS PEK LET-THRU CURRENTIN MPS,000 80,000 60,000 40,000 30,000 20,000,000 8,000 6,000 4,000 3,000 2,000,000,000 2, ,000 6,000 8,000,000 20,000 30,000 40,000 60,000 80,000,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 x SYMM RMS MPS) 200,000.0,000 RMS SYMMETRICL CURRENT IN MPS,000 53
8 a Ca a to Cat. No. CCL(mps) 600Vac or Less C Interrupting Rating: 200k With open fuse indicator UL Recognized (80 to 50 amps) E5642, JFHR2 Non-Time Delay mp Ratings CCL Characteristics: Stud mount with tapped terminals Isolates faulted capacitor Size amp rating 50% to 75% of capacitor rated amps Maximum quality assurance Cat. No. CCLW(mps) 600Vac or Less C Interrupting Rating: 200,000 mps Without open fuse indicator UL Recognized mps, (E5642, JFHR2) Non-Time Delay mp Ratings CCLW Characteristics: Stud mount and pressure plate terminals Isolates faulted capacitor Size amp rating 50% to 75% of capacitor rated amps Maximum quality assurance Dimensions - inches Dimensions - inches /2" 3-3/6" 2-9/32" 2" -/32" 3/6" 3/6" /2" 3-7/32".0" INDICTOR " -/2" /2"-3 THREDS /6" DEEP LOWN POSITION 3/8"-6 THREDS 3/4" DEEP HEX TERMINL TPPED /2"-3 x /6" DEEP 54
9 a Ca a to verage Time-Current Curve Circuit Protection Cat. No. CCL or CCLW (mp) MP RTING TIME IN SECONDS ,000 2,000 3,000 4,000 6,000 8,000,000 RMS SYMMETRICL CURRENT IN MPS 55
10 ft t atte C a e Catalog Number CK (5-400), CL (30 - ) and LS ( - 500) s: Popular for protection of DC circuits in fork lift trucks and battery chargers. Catalog Dimensions (Inches) Number Type Volts mps C 5, 20, 25, Vdc 35, 40, 50, CK Time-Delay 70, 75, 80, Vdc 20, 40, 50, 75, Vdc 225, 250, 300, CL Time-Delay 72Vdc 30, 35, 40, 50, 60 80, Non-Time 30Vdc, 20, 40, 50, 75 LS Delay 200, 225, 250, Vdc 350, 400, 450, 500 Dimensions - inches C (Dia.) 56
11 o olta e te on T e ela Catalog Number NL (35-500) 25Vac or Less 2.44" (6.9mm) 0.88" (22.2mm) 0.34" (8.7mm) 3.9" (8.0mm) Circuit Protection verage Time-Current Curve MP RTING 0.34" (8.7mm) 0.88" (22.2mm) TIME IN SECONDS mp Ratings NL 25Vac NL Specifications: Non-Time-Delay Voltage Rating: Interrupting Rating: 80Vdc, 25Vac 6,000 mps Recommended Fuse lock: 464 Characteristics: Isolates faults in equipment systems such as lift trucks and other battery operated systems. Silver-plated copper links. Link element visible through mica window CURRENT IN MPS Fuse lock 464 Holes drilled 0.27 diameter with counterbore with 5/6-24 stud. Dimensions - inches.563" " ", /32" 5/6" 57
12 te e ast t n Catalog Number NN (35-800) 25 Volts C or Less 0.88" (22.2mm) verage Time-Current Curve MP RTING 2.44" (6.9mm) 0.34" (8.7mm) 3.9" (8.0mm) 0.34" (8.7mm) 0.88" (22.2mm) TIME IN SECONDS mp Ratings NN 25Vac NN Specifications: Very Fast-cting Voltage Rating: Interrupting Rating: 80Vdc, 25Vac 2,500 mps Recommended Fuse lock: 464 Characteristics: Very fast-acting (high spd of response to short-circuit currents. Link element visible through mica window. UL Recognized (Guide #JFHR2, File #E5642)..0 0 CURRENT IN MPS Fuse lock 464 Holes drilled 0.27 diameter with counterbore with 5/6-24 stud. Dimensions - inches.563" " , " 3-3/32" 5/6" 58
13 Circuit Protection Standard Ratings Catalog mp UL Component Recognition Voltages Number Ratings Vac C IR Vdc DC IR 30V E3S (mp) , V E5SF(mp) 5 60 E5S(mp) , E25SFX(mp) , V E25S(mp) , ,000 E25S(mp) E50SF(mp) , V E50S(mp) , ,000 E50S(mp) , V E60C(mp) , V E60SF(mp) 5 30 E60S(mp) ,000 E70SF(mp) , V E70S(mp) , ,000 E70S(mp) ESF(mp) V ES(mp) , ES(mp) Technical Data In many ca, the data in this catalog section which includes available ratings, dimensions, time current characteristics and I 2 t let-through, will enable a suitable choice of fuse to be made. The following notes are a guide to assist fuse selection. Voltage Rating The test voltage is equal to the rated voltage. The DC voltage ratings are tested with a time constant of ms. For longer time constants the following typical derating factors apply: Time constant ms Voltage derating factor Current Rating The maximum current carrying capability is at least equal to the current rating, provided that the ambient temperature is less than 30 C, conductor sizes are at least mm 2 per amp, and there is natural convection cooling. For ambient temperatures higher than 30 C, a derating of 0.5% per C is recommended. In situations where the air temperature surrounding the fuse is higher than the ambient temperature, i.e. inside a converter cubicle, the derating should be based on the air temperature surrounding the fu. In many installations, power semiconductors are force cooled in an air stream. Fu can be mounted in this air stream and their maximum current carrying capability can then be increased. This increase is up to approximately 20% in an air velocity of 5m/s but higher velocities do not produce any substantial increase in rating. 59
14 Power Dissipation The values of watts loss given are related to full rated current with the correct sizes of conductors and natural cooling. Time Current Characteristics Individual time current characteristics are subject to a ±% tolerance on current and are based on symmetrical sinusoidal 60Hz currents. High spd fu are designed to clear fault currents associated with pre-arcing times of 30 seconds or less. Dashed lines on time-current characteristic curves represent overload conditions which, should always be avoided. Permitted Overloads In many applications, surges occur during the normal duty of equipment and under such permitted overloads, the fuse must not open. For permitted overloads lasting longer than a few minutes, the fuse current rating should be selected based on the overload current. The current rating of the fuse should excd the overload current. For infrequent normal overloads, fuse selection can be made on the basis of an overload curve of not more than 75% of the published time current characteristic. For highly repetitive overloads, such as in a stl mill thyristor drive, fuse selection should be made on the basis of an overload curve of not more than 60% of the published time current characteristic. I 2 t Characteristics The melting I 2 t of fu is independent of voltage and reduces to a minimum value for times less than about ms. For longer times, reference should be made to the time current characteristics. The total I 2 t values for operating times less than one halfcycle are shown in the data shts and relate to a fault current of at least 20x rated current, In, with a power factor of 5%. The total I 2 t values reduce considerably at voltages below the rated voltage since the arc interruption is easier. reaking Capacity In general, high spd fu perform well at very high fault currents and many products have bn successfully tested up to 200k rms symmetrical. The fu are essentially for short-circuit protection and therefore in general, only required to clear faults for melting times less than 30 seconds. Peak Let-Through Current Curves Short-circuit coordination of power semiconductors is assed with the use of I 2 t values. Traditional supplementary peak let-through current curves are also shown in the catalog. rc-voltage Characteristics s using modern power semiconductors are not normally sensitive to the peak arc voltages produced by Edison high spd fu. Typical values of arc voltages in relation to the rated fuse voltage, Un, are: System Voltage rc Voltage of Fuse U n 2.0 U n 0.5 U n.25 U n 0.2 U n 0.7 U n Example: a 500 volt Edison high spd fuse used on a 250 volt system would produce an arc voltage of approximately 625 volts. 60
15 Catalog Number E3S(mp) 30Vac/30Vdc Circuit Protection Dimensions - inches UL Recognized E3S(mp) Dimensions - inches Catalog Numbers Figure C Threat Depth E350HP Tapped 3 /8-24 x /2 E3S Tapped /2-20 x /2.875 C Figure : mp Range E3S(mp) Electrical Characteristics Catalog Numbers Rated Current RMS mps Melting I 2 t Clearing I 2 30V Watts Rated Current E3S0HP 0 70, , E3S , , E3S ,000,400, E3S ,000 2,400,000 8 E3S ,500,000 4,, E3S ,,000 5,700, NOTE: To cross reference 30V high spd fu below 0 amps, refer to upgraded Edison E5S(mp) 50V fu. Minimum Melting Curves E3S0 3000, 30V Peak Let-Through Current Curves E3S0 3000, 30V MP RTING 0,000 TIME IN SECONDS. INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000, MP RTING ,000,000 CURRENT IN MPS,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS) 6
16 Catalog Number E5SF5 60 Dimensions - in (mm) UL Recognized E5SF(mp) Dimensions - inches (mm) Catalog Numbers Figure C E5SF (38.) (9.5) (.3) E5SF (50.8) (5.9) 0.82 (20.6) Figure : 5 60 mp Range C Catalog Number E5S70 0 E5S(mp) Dimensions - inches (mm) Catalog Numbers Figure C D E F G H E5S (67.5) (52.4).56 (29.4).000 (25.4) 0.25 (3.2) (9.) 0.32 (7.9) (.) E5S (88.9) (6.9).250 (3.8).500 (38.) (6.4).000 (25.4) (.3) (.3) F C D E G H Figure 2: mp Range C E F G D H Figure 3: mp Range 62
17 Circuit Protection Catalog Number E5SF(mp) 50Vac/30Vdc E5SF(mp) 50Vac/30Vdc Electrical Characteristics Catalog Number Rated Current RMS mps Melting I 2 t Clearing I 2 50V Watts Rated Current E5SF E5SF E5SF E5SF E5SF E5SF E5SF E5SF E5SF E5SF E5SF Catalog Number E5S(mp) 50Vac/50Vdc* E5S(mp) 50Vac/50Vdc Electrical Characteristics Catalog Number Rated Current RMS mps Melting I 2 t Clearing I 2 50V Watts Rated Current E5S E5S E5S E5S E5S E5S E5S E5S E5S E5S E5S E5S E5S E5S E5S Interrupting Rating 200k RMS Symmetrical. *50Vdc rating applies to amps only. 63
18 E5SF(mp) High Spd Fuse 5 60 mps, 50 Volts Time-Current, Minimum Melting Curves E5S(mp) High Spd Fuse 70 0 mps, 50 Volts MP RTING MP RTING TIME IN SECONDS TIME IN SECONDS..0 CURRENT IN MPS,000..0,000 CURRENT IN MPS,000 E5SF(mp) High Spd Fuse 5 60 mps, 50 Volts,000 Peak Let-Through Current Curves E5S(mp) High Spd Fuse 70 0 mps, 50 Volts,000,000 INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS, MP RTING INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000, MP RTING RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 2,000,000,000,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 64
19 Catalog Number E25SFX(mp) 5 30 mps, 250Vac/250Vdc Circuit Protection Dimensions - inches (mm) 50.8 (2.000") 5.5 (0.6") 4.3 (0.563") Catalog Number E25S(mp) mps E25S(mp) Dimensions - inches (mm) Catalog Numbers Figure C D E F G H J E25S (8.0) 0.8 (20.6).59 (40.4) 2.59 (65.8) 2.25 (57.2) 0.34 (8.6) 0.63 (6.0) 0.3 (3.3) 0.52 (3.2) E25S (79.5).22 (3.0).59 (40.4) 2.44 (62.0) 2.9 (55.6) 0.34 (8.6).00 (25.4) 0.9 (4.8) 0.47 (.9) E25S (97.5).50 (38.).59 (40.4) 2.94 (74.7) 2.25 (57.2) 0.4 (.4).00 (25.4) 0.25 (6.4) 0.75 (9.) E25S (97.5) 2.00 (50.8).59 (40.4) 3.03 (77.0) 2.28 (57.9) 0.4 (.4).50 (38.) 0.25 (6.4) 0.78 (9.8) E25S (65.8) 3.00 (76.2).50 (38.) E25S (65.8) 3.50 (88.9).50 (38.).50 (38.) D E C H G F J Figure : mp Range Thread Depth Tapped 3 /8-24 x /2 D C C Figure 2: mp Range Figure 3: mp Range 65
20 Catalog Number E25S(mp) 250Vac/250Vdc* * UL Recognized E25S(mp) 250Vac/250Vdc* Electrical Characteristics Catalog Numbers Rated Current RMS mps Melting I 2 t Clearing I 2 250V Watts Rated Current E25SFX E25SFX E25SFX E25SFX E25SFX E25SFX E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S E25S Interrupting Rating 200k RMS Symmetrical. *250Vdc rating and UL Recognition on amps only. 66
21 E25SFX(mp) High Spd Fuse 5 30 mps, 250 Volts Time-Current, Minimum Melting Curves E25S(mp) High Spd Fuse mps, 250 Volts Circuit Protection MP RTING, MP RTING TIME IN SECONDS TIME IN SECONDS..0 4 CURRENT IN MPS,000 3,000. CURRENT IN MPS,000,000 Peak Let-Through Current Curves E25SFX(mp) High Spd Fuse 5 30 mps, 250 Volts INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000,000,000,000,000 20, MP RTING RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS) E25S(mp) High Spd Fuse mps, 250 Volts INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000,000,000,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 20, MP RTING 67
22 Time-Current, Minimum Melting Curves E25S(mp) High Spd Fuse mps, 250 Volts, MP RTING TIME IN SECONDS.,000,000 CURRENT IN MPS,000 68
23 Catalog Number E50SF(mp) 5 30 mps, 500Vac/500Vdc Circuit Protection Dimensions - inches (mm) 50.8 (2.000") 4.3 (0.563") 5.5 (0.6") Catalog Number E50S(mp) mps, 500Vac/500Vdc* E50S(mp) Dimensions - inches (mm) Catalog Numbers Figure C D E F G H J E50S (8.0) 0.8 (20.6).59 (40.4) 2.59 (65.8) 2.25 (57.2) 0.34 (8.6) 0.63 (6.0) 0.3 (3.3) 0.52 (3.2) E50S (92.2).00 (25.4) 2.09 (53.) 3.03 (77.0) 2.69 (68.3) 0.34 (8.6) 0.75 (9.) 0.3 (3.3) 0.52 (3.2) E50S (92.2).22 (3.0) 2.09 (53.) 2.94 (74.7) 2.69 (68.3) 0.34 (8.6).00 (25.4) 0.9 (4.8) 0.47 (.9) E50S (.0).50 (38.) 2.09 (53.) 3.44 (87.4) 2.75 (69.9) 0.4 (.4).00 (25.4) 0.25 (6.4) 0.75 (9.) E50S (.0) 2.00 (50.8) 2.09 (53.) 3.53 (89.7) 2.78 (70.6) 0.4 (.4).50 (38.) 0.25 (6.4) 0.78 (9.8) E50S (6.0) 2.50 (63.5) 2.09 (53.) 4.97 (26.2) 3.44 (87.4) 0.53 (3.5) 2.00 (50.8) 0.38 (9.7).30 (33.0) E50S (77.0) 3.00 (76.2) 3.22 (8.8) 5.47 (38.8) 4.48 (3.7) 0.63 (5.9) 2.38 (60.3) 0.44 (.).2 (28.4) E50S S Drawing G F D E C J H Figure : mp Range Figure 2: mp Range 69
24 Catalog Number E50S(mp) 500Vac/500Vdc* UL Recognized E50S(mp) 500Vac/500Vdc * Electrical Characteristics Catalog Numbers Rated Current RMS mps Melting I 2 t Clearing I 2 500V Watts Rated Current E50SF E50SF E50SF E50SF E50SF E50SF E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S E50S Interrupting Rating 200k RMS Symmetrical. *500Vdc rating and UL Recognition on amps only. UL Recognition on amps only. 70
25 E50SF(mp) 5 30 mps, 500 Volts E50S(mp) mps, 500 Volts Time-Current, Minimum Melting Curves E50S(mp) High Spd Fuse mps, 500 Volts Circuit Protection MP RTING, MP RTING TIME IN SECONDS TIME IN SECONDS..0,000 CURRENT IN MPS,000 30,000.,000 CURRENT IN MPS,000 E50SF(mp) High Spd Fuse 5 30 mps, 500 Volts INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS) Peak Let-Through Current Curves,000 2, MP RTING E50S(mp) High Spd Fuse mps, 500 Volts INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000,000,000,000,000 20, MP RTING RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS) 7
26 Catalog Number E60C( 0) 600 Volts C or Less NOTE: Edison 600V rectifier fu are for replacement purpo only. For new applications, refer to E70S(mp) fu. mp Ratings E60C(MP) 600V E60C(mp) Dimensions - inches Catalog Numbers Figure 2 3 C D E F G H E60C E60C E60C E60C E60C E60C E60C D C F G H Figure : 4 30 & mp Range D E 2 3 C F G H Figure 2: mp Range 72
27 Total Clearing Time Curves E60C 800, 600Vac Circuit Protection verage Melting Time-Current Curves E60C35 60, 600Vac MP RTING MP RTING TIME IN SECONDS. TIME IN SECONDS.0 CURRENT IN MPS,000, CURRENT IN MPS,000,000 73
28 Catalog Number E60SF(5 30) 600 Volts C or Less NOTE: Edison 600V rectifier fu are for replacement purpo only. For new applications, refer to E70S(mp) fu. mp Ratings E60SF(MP) 600V Dimensions - inches (mm) E60SF(MP) Dimensions - inches (mm) Catalog Numbers E60SF5 30 S Drawing 5.000" 27.00mm 0.83" 20.63mm Catalog Number E60S(35 600) 600 Volts C or Less mp Ratings E60S(MP) 600V E60S(mp) Dimensions - inches Catalog Numbers Figure C D F G H E60S35 60 S Drawing E60S E60S E60S E60S Figure : mp Range C G D F Figure 2: mp Range H 74
29 Total Clearing Time Curves E60S(mp) 600Vac Circuit Protection MP RTING TIME IN SECONDS..0,000 CURRENT IN MPS,000 30,000 75
30 Catalog Number E70SF(5 30) 700Vac/700Vdc E70SF(MP) Dimensions - inches (mm) Catalog Number E70SF5 30 S Drawing Dimensions - inches (mm) 2.000" 50.8mm 0.563" 4.3mm 0.6" 5.5mm Catalog Number E70S(35 200) 700Vac/700Vdc* E70S(mp) Dimensions - inches (mm) Catalog Numbers Figure C D E F G H J E70S ().00 (25.4) 2.84 (72.) 3.78 (96) 3.44 (87.4) 0.34 (8.6) 0.75 (9.) 0.3 (3.3) 0.52 (3.2) E70S ().22 (3) 2.84 (72.) 3.69 (93.7) 3.44 (87.4) 0.34 (8.6).00 (25.4) 0.9 (4.8) 0.47 (.9) E70S (29).50 (38.) 2.84 (72.) 4.9 (6) 3.50 (88.9) 0.4 (.4).00 (25.4) 0.25 (6.4) 0.75 (9.) E70S (29) 2.00 (50.8) 2.84 (72.) 4.28 (9) 3.53 (89.7) 0.4 (.4).50 (38.) 0.25 (6.4) 0.78 (9.8) E70S (80) 2.50 (63.5) 2.84 (72.) 5.72 (45) 4.9 (6) 0.53 (3.5) 2.00 (50.8) 0.38 (9.7).30 (33) E70S (68) 2.00 (50.8) 2.84 (72.) 5.56 (4.2) 5.06 (28.6) 0.63 (5.9).50 (38.) 0.25 (6.4) 0.88 (22.2) E70S S Drawing E70S200 3 S Drawing D E C H G F Figure : mp Range J Figure 2: mp Range Figure 3: 200 mp Range 76
31 Catalog Number E70S(mp) 700Vac/700Vdc* Circuit Protection UL Recognized E70S(mp) 700Vac/700Vdc * Electrical Characteristics Catalog Number Rated Current RMS mps Melting I 2 t Clearing I 2 700V Watts Rated Current E70SF E70SF E70SF E70SF E70SF E70SF E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S E70S Interrupting Rating 200k RMS Symmetrical *700Vdc rating applies to amps only. 77
32 Pre-rcing Time-Current Curves E70SF(mp) 5 30 mps, 700 Volts Minimum Melt Time-Current Curves E70S(mp) mps, 700 Volts MP RTING, MP RTING TIME IN SECONDS TIME IN SECONDS..0 CURRENT IN MPS,000.,000 CURRENT IN MPS,000 Peak Let-Through Current Curves E70SF(mp) 5 30 mps, 700 Volts,000 E70S(mp) mps, 700 Volts,000 INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS, MP RTING INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000, MP RTING RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 2,000,000,000 20,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS) 78
33 Minimum Melt Time-Current Curves E70S(mp) mps, 700 Volts Circuit Protection Peak Let-Through Current Curves E70S(mp) mps, 700 Volts TIME IN SECONDS MP RTING,000 INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000,000,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 20, MP RTING.0 40,000,000 30,000 CURRENT IN MPS 79
34 s Catalog Number ESF(20 30) 0Vac/800Vdc ESF(MP) Dimensions - inches (mm) Catalog Numbers ESF20 30 S Drawing Dimensions - inches (mm) 2.626" 66.7mm 0.625" 5.9mm 0.57" 4.5mm Catalog Number ES(40 800) 0Vac/700Vdc ES(mp) Dimensions - inches (mm) Catalog Numbers Figure C D E F G H J ES (27.0) 0.94 (23.9) 3. (79.0) 4.24 (7.6) 4.8 (6.2) 0.35 (8.9) 0.75 (9.) 0.3 (3.2) 0.38 (9.7) ES (25.3).3 (28.6) 3.09 (78.4) 4.27 (8.4) 4.6 (5.6) 0.35 (8.9).00 (25.4) 0.9 (4.8) 0.4 (.3) ES (44.4).53 (38.8) 3.26 (82.8) 4.63 (7.6) 4.58 (6.4) 0.45 (.3).00 (25.4) 0.25 (6.4) 0.47 (.9) ES (46.5) 2.00 (50.8) 3.50 (88.9) 4.8 (22.2) 4.5 (5.4) ).50 (38.) 0.25 (6.4) 0.76 (9.4) ES (82.9) 2.50 (63.5) 3.47 (88.0) 5.98 (52.0) 4.7 (9.5) 0.56 (4.3) 2.00 (50.8) 0.38 (9.5).20 (30.5) ES (73.0) 3.50 (88.9) 3.3 (84.) 5.47 (39.0) 4.96 (26.0) 0.63 (5.9) 2.75 (69.9) 0.50 (2.7) 0.88 (22.4) D E C H G F Figure : mp Range J 80
35 Catalog Number ES(mp) 0Vac/700Vdc* Circuit Protection UL Recognized ES(mp) 0Vac/700Vdc * Electrical Characteristics: Catalog Number Rated Current RMS mps Melting I 2 t Clearing I 2 0V Watts Rated Current ESF ESF ESF ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES ES Interrupting Rating 200k RMS Symmetrical *mp ratings rated up to 800Vdc. UL Recognition through 200 amps only. 8
36 Pre-rcing Time-Current Curves ESF(mp) mps, 0Vac/800Vdc Minimum Melt Time-Current Curves ES(mp) mps, 0Vac/700Vdc MP RTING MP RTING TIME IN SECONDS TIME IN SECONDS...0 CURRENT IN MPS,000,000.0,000 CURRENT IN MPS,000 Peak Let-Through Current Curves ESF(mp) mps,000 ES(mp) mps,000 INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS, MP RTING INSTNTNEOUS PEK LET-THROUGH CURRENT IN MPS,000, & MP RTING,000 2,000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 RMS SYMMETRICL CURRENTS IN MPS =SYMMETRICL VILLE PEK (2.3 X SYMM RMS MPS),000 50,000 82
37 ts t le s Circuit Protection Introduction ritish S 88 Contents Fuse Volts mp Range ccessories Indicator System (s end of this section) Fuse locks (s H Series fuse blocks in this catalog) ritish S 88 Fuse Ranges mps Volts C DC X X X X General Information Designed and tested to: S 88: Part 4 IEC 269: Part 4 UL Recognized We offer the industry s widest range of ritish style semiconductor fu and accessories. Edison ritish style products use innovative arc quenching techniques and high grade materials to provide: Minimal energy let-through (I 2 t) Excellent DC performance Good surge withstand profile ritish style fu are typically found in equipment manufactured in the United Kingdom or ritish Commonwealth countries. However, North merican manufacturers have begun to specify ritish style fu particularly in UPS applications at 240V or less to take advantage of their size, performance and cost benefits. Voltage Rating ll Edison ritish style fu are tested to IEC 269: Part 4. This standard requires a test voltage which is 5% higher than the rated voltage. In North merica, fu are required to clear only their rated voltage. ccessories Trip-indicator fu are available for use in parallel with the main fuse. Indicator fu can be attached to the associated fuse, or mounted separately in panel-mounted fuseclips. In addition, a push-on adapter and microswitch attachment are available, to provide remote indication. The H Series fuse blocks are also available for most applications. 83
38 ts t le 660 Volt (C) Range I 2 t Carton Part Clearing Clearing Watts DC Carton Weight Type Outline Number Pre-arc t 45V t 690V Loss Volts Qty. (kg) ET 25ET ET FE FE FE FE FE 2.50" 63FE mm 7FE FE FE FE FEE FEE FEE 40FEE FEE FEE " 200FEE mm 80FM FM FM FM 250FM FM "-3.35" 80-85mm 35FM FM FMM FMM FMM 500FMM FMM FMM FMM "-3.35" 80-85mm Interrupting rating 200k RMS Symmetrical. Watts loss provided at rated current. These fu mt the requirements of S 88 Part 4 and IEC Consult Edison Customer Satisfaction for UL Recognition information. 84
39 ts t le 240 Volt (C) Range Circuit Protection I 2 t Carton Part Clearing Clearing Watts DC Carton Weight Type Outline Number Pre-arc t 20V t 240V Loss Volts Qty. (kg) 6LCT LCT LCT 2LCT " 38.0mm 6LCT LCT LET LET LET 35LET LET LET " 4.8mm 80LET LET LET LET LET LMT LMT LMT LMT 35LMT LMT " 59.0mm 400LMT LMT LMMT LMMT LMMT LMMT 400LMMT LMMT LMMT " 59.0mm Interrupting rating 200k RMS Symmetrical. Watts loss provided at rated current. ll fu above have bn tested to 38Vac. These fu mt the requirements of S 88 Part 4 and IEC UL Recognition on LET and LMT. Others pending Consult Edison Customer Satisfaction. 85
40 ts t le Dimensions - mm Type C D E F G H LCT FE & ET LET FEE FM LMT FMM LMMT LCT FE, ET & LET FEE FM & LMT FMM & LMMT 86
41 ts t le 690V Time-Current Curves FEE (-200) FMM ( ) MP RTING Circuit Protection 690V Time-Current Curves FC (6-20) FE (35-) FM (80-350) MP RTING TIME IN SECONDS CURRENT IN MPS,000 CURRENT IN MPS
42 ts t le 240V Time-Current Curves LMT (60-450) 240V Time-Current Curves LCT (6-20) LET (25-80) LMMT ( ) MP RTING MP RTING TIME IN SECONDS TIME IN SECONDS CURRENT IN MPS CURRENT IN MPS,000 88
43 t s t le n ato s esso es Indicator System Trip-Indicators Trip-indicators are available for use in parallel with the main fuse. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips, reference CL. push-on adapter and microswitch attachment is available for use with the trip indicator to give the facility of remote indication, reference MI. Fuse ratings of 20 and below cannot usually accommodate a trip-indicator. When a trip-indicator is to be attached to the main fuse an accessory pack comprising a pair of mounting clips and an appropriate trip indicator would be required. The clips are snapped onto the fuse end caps and the indicator is pressed into clips as shown. Electrical Specifications Type TI500 TI700 Maximum RMS Voltage Maximum Peak Voltage Maximum DC Voltage Cold Resistance (ohms) Maximum permissible steady-state current.5.5 Interrupting Capacity (RMS Symm.),000,000 Pre-rcing I 2 t Fuse Indicator Kits RMS For use Kit. Ref. Details Volts with Fuse Ref. EC-250 Fuse Mount 250 LET MC250 Indicator Kits 250 LMT & LMMT EC-600 (Includes one 660 FE, FEE & ET MC600 indicator 660 FM & FMM MC700 and two clips) 700 MT & MMT CL Panel Mount Clips CL Panel mount fuse clips are available for mounting a trip-indicator when mounting directly on the fuse is impractical. Order part number CL. Microswitch dapter MI We offer a microswitch, complete with adapter for securing the indicator. The microswitch is provided with double pole, single throw contacts, having both a normally open and a normally closed position. special material has bn employed in the construction of the adapter to provide reliable operation in the range of temperatures associated with standard operating conditions and during fuse operation. Microswitch and dapter Type MI Trip-Indicator Dimensions - mm C6 2 E0.8 Circuit Protection Ref. Dim. (mm) RMS Volts TI TI TI TI TI 98.4 TI TI TI CL Panel Mount Clip Dimensions - mm Terminal rrangement Dimensions in mm NO NC NC NO D 6.8 F Current Rating: C 50/60Hz resistive 250V RMS C 50/60Hz resistive 27V RMS DC, resistive Vdc DC, resistive 30Vdc Maximum Working Voltage: Contact-to-contact (RMS) Contact-to-contact (RMS) Maximum DC Volts: DC 2 DC 0V 500V V DC 89
44 UL FUSES CURRENT LIMITING t s Cana an tan a n st al SPECIL PURPOSE FUSES UL FUSES GENERL PURPOSE CNDIN FUSES & HOLDERS MEDIUM VOLTGE FUSES FUSE LOCKS, HOLDERS & MISC. Type D ottle Fuse mp Ratings: 2 to mps Voltage Ratings: 500Vac Interrupting Rating: k gency pprovals: D type fu complying with DIN (time lag) 2 and DIN 4955, operating class gg/gl Catalog Dimension mpere Color Figure Number D Rating Code Number 2D6 6 2 Pink 4D6 6 4 rown 6D6 6 6 Grn D6 8 Red 6D6 6 Gray 20D lue 25D Yellow 2D Pink 4D rown 6D Grn D27 8 Red 2 6D27 6 Gray 20D lue 25D Yellow 35D lack 50D White 3 63D Copper 80D Silver D25 7 Red 4 dditional fuse links: Quick acting fuse links in body size D6, D27, D33 and D25 rated 2- amps. Reference number with suffix Q, i.e. D27Q. Voltage rating 500 volts ultra fast-acting fuse links in body size D27, D33, and D25 rated 6- amps. Reference number with suffix R, i.e., D27R. Notes: (a) Gauge rings and keys can also be supplied. Dimensions - mm Neozed Fuse lso suitable for use on 250Vdc systems. mp Ratings: 2 to 63 mps Voltage Ratings: 400Vac Interrupting Rating: k Catalog Dimension Contact mp Color Number D Diameter D Rating Code 2NZ Pink 4NZ rown 6NZ Grn NZ0 8.5 Red 6NZ Gray 20NZ lue 25NZ Yellow 35NZ lack 50NZ White 63NZ Copper Dimensions - mm PPLICTION SECTION Figure Figure 2 Figure 3 Figure 4 90
45 o ean t le ne ote t on Circuit Protection Catalog Number NH HRC Fuse Links Class of Operation: gg/gl mp Ratings: 2 to 250 mps Voltage Ratings: 500Vac Sizes: 000 to 4 Standards/pprovals: IEC 60269, VDE0636, DIN part to 4, VDE mark and CE Description: square bodied range of industrial fuse links for a wide variety of applications. Packaging: 3's, except size 4 packed in Ordering Code: Rating/Type Size Category, e.g., 63NHG000 Technical Data: Contact Edison Customer Satisfaction for curves and I 2 t Data. Rated Voltage: 500Vac Rated reaking Capacity: 20k Rated Frequency: 50 Hz Operating Frequency: Hz Selectivity: :.6 up to 500Vac Design - Insulator: Ceramic - Metal Parts: Corrosion-proof (top plate also galvanic plated) Contact lades: Full contact and insulated blades available, silver-plated brass. Protection Type: IP00 according to DIN40050 Dimensions: DIN Tests: VDE 0636/22 Constancy of Characteristics: Resistant of aging. On/Off Indicator: Patented spring dual indication Mechanical Stress: Vibrations 7 up to 50Hz with g, shocks with 5 g. Environmental: % recyclable, RoHS compliant, cadmium and lead fr across entire range, corrosion fr screws. Dimensions - mm a2 b c c2 D e e2 e3 e4 f Size a a (max) a3 a4 (rated) (±8) (rated) (rated) (max) (max) (max) (rated) (max) ± ±.5 49± ± ± ±.5 49± ± ± / / ± ± ±2.5 68± ± ± ±2.5 68± ± ± ±2.5 68± ± ± ±2.5 68± ± ± ±2.5 68± ± ± ±2.5 68± ±
46 o ean t le ne ote t on 500 gg-gl Dual Indicator 500 gg-gl with voltage fr mp Dual Indicator metal gripping lugs Size Rating Part Number Part Number 2 2NHG000 2NHG000I 4 4NHG000 4NHG000I 6 6NHG000 6NHG000I NHG000 NHG000I 6 6NHG000 6NHG000I 20 20NHG000 20NHG000I 25 25NHG000 25NHG000I NHG000 32NHG000I 35 35NHG000 35NHG000I 40 40NHG000 40NHG000I 50 50NHG000 50NHG000I 63 63NHG000 63NHG000I 80 80NHG000 80NHG000I NHG000 NHG000I NHG00 25NHG00I 60 60NHG00 60NHG00I NHG0 6 6NHG NHG NHG NHG NHG NHG NHG NHG NHG0 NHG NHG NHG0 NHG0 NHG0I 6 6NHG0 6NHG0I 20 20NHG0 20NHG0I 25 25NHG0 25NHG0I 32 32NHG0 32NHG0I 35 35NHG0 35NHG0I NHG0 40NHG0I 50 50NHG0 50NHG0I 63 63NHG0 63NHG0I 80 80NHG0 80NHG0I NHG0 NHG0I 25 25NHG0 25NHG0I 60 60NHG0 60NHG0I NHG 200NHGI NHG 224NHGI NHG 250NHGI 35 35NHG* NHG* 35 35NHG02 35NHG02I 40 40NHG02 40NHG02I 50 50NHG02 50NHG02I 63 63NHG02 63NHG02I 80 80NHG02 80NHG02I 02 NHG02 NHG02I 25 25NHG02 25NHG02I 60 60NHG02 60NHG02I NHG02 200NHG02I NHG02 224NHG02I NHG02 250NHG02I 500 gg-gl Dual Indicator 500 gg-gl with voltage fr mp Dual Indicator metal gripping lugs Size Rating Part Number Part Number 35 35NHG2 35NHG2I NHG2 355NHG2I NHG2 400NHG2I NHG NHG03 250NHG03I NHG03 35NHG03I NHG03 355NHG03I NHG03 400NHG03I NHG NHG3 500NHG3I NHG NHG4G 4 Slotted NHG4G End Tags NHG4G 0 0NHG4G NHG4G * Denotes 440V 92
Now even more application possibilities In all facets of semiconductor protection
Semiconductor Protection Fuses sitor ENGINEERING s Now even more application possibilities In all facets of semiconductor protection For decades now, SITOR semiconductor protection fuses have been reliably
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationL50QS SERIES HIGH-SPEED ROUND BODY FUSES
00 Vac/dc -0 A Traditional Round Body Bolted Style HF Specifications Voltage Rating Amperage Rating Interrupting Rating Time Constant Material Approvals Environmental Country of Origin AC: 00V DC: 00V
More informationL70QS SERIES HIGH-SPEED ROUND BODY FUSES
Vac/dc - Traditional Round Body Bolted Style HF Description The LQS Series is a next generation High-Speed Fuse for the protection of power semiconductor devices and is designed in the Traditional North
More informationIELR Rail-Mount Series Magnetic Circuit Protectors
IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationTime Delay Values (E-Series)
Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short
More informationIELR Series
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic
More informationL70S SERIES HIGH-SPEED FUSE
LS SERIES HIGH-SPEED FUSE 0 Vac Vdc 0-0 Traditional Round Body Style Description Littelfuse LS Series High-Speed Fuses are designed to protect today s equipment and systems, and are manufactured with Littelfuse-developed
More informationNH fuse-links gg VAC with striker size 0, 1, 2, 3, 4
NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose
More informationAMP-TRAP Form 101 A15QS
AMP-TRAP Form 0 AQS SEMICONUCTOR PROTECTION FUSES AQS Amp-trap Form 0 Semiconductor Protection fuses were designed for the specific protection of diodes and other semiconductor devices rated VAC/C. The
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers
More informationL50S SERIES HIGH-SPEED FUSE
POWR-GRD Fuse Datasheet LS SERIES HIGH-SPEED FUSE 0 Vac Vdc 0-0 Traditional Round Body Style Description Littelfuse LS Series High-Speed Fuses are designed to protect today s equipment and systems, and
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less
Catalog Number ECNR ( - 600A) 250Vac or Less Catalog Number ( - 600A) 600Vac or Less Amp Ratings ECNR 8 25 70 50 400 2 9 30 75 75 450 3 35 80 200 500 4 2 40 90 225 600 5 5 45 250 6 7.5 50 300 7 20 60 25
More information209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards
The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker
More informationL70S SERIES HIGH-SPEED FUSE
LS SERIES HIGH-SPEED FUSE 0 Vac Vdc 0-0 Traditional Round Body Style Description Littelfuse LS Series High-Speed Fuses are designed to protect today s equipment and systems, and are manufactured with Littelfuse-developed
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationSpecial Purpose Fuses
Cable Protectors CP & CPH Ferraz Shawmut CP Cable Protectors are special purpose limiters which are crimped or bolted to cables to clear and isolate faults quickly, increasing the reliability of service
More informationIhr autorisierter Distributor: Neumüller Elektronik GmbH
IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationSeries LS. 30A to 600 Vac SIP Package DC control LS 24 D 16 C. Figure 1 LS relays; dimensions in inches (mm) (See Figure 12 for LS with HS1)
3A to 6 Vac SIP Package DC control Part Number LSD16C LSD1C LS6DC LSD7C LS6D7C LS6D3C Description 16A, Vac 1A, Vac A, 6 Vac 7A, Vac 7A, 6 Vac 3A, 6 Vac Part Number Explanation LS D 16 C NOTES 1) Line Voltage
More informationBOARD LEVEL POWER SEMICONDUCTOR HEAT SINKS
217 SERIES Surface Mount D 2 PAK,, SOT-223, SOL-2 Compatible with surface mount technology (SMT) automated production techniques for ease of assembly and a variety of soldering methods, these heat sinks
More informationMagnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158
Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70
More informationPS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.
Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized
More informationVoltage Current Front-mounting bracket
Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationPERCENT OF RATED CURRENT
A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationProducts :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers
Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationAPL/UPL, 205/295 Series Magnetic Circuit Protectors
APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationTerminal Blocks - Single Row. Series A2000, LP2000 & CB2000 Single Row Terminal Blocks
Series A2000, LP2000 & C2000 Single Row Terminal A20510807WR SPECIFICATIONS Rating: A2: 30A, 300V* LP2: 30A, 150V* C2: 30A, 300V* Center Spacing: 0.375 or 3/8 (9.52mm) Wire Range: #12-22 AWG CU Screw Size:
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationElectrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.
MLP75 Medical Features 3 x 2 x 1 Inches Form factor 75 Watts Convection Approval to EN60601 3 rd Edition Efficiencies upto 93% -40 to 70 degree operating temperature Dual fusing Thermal Shut-Down feature
More informationE-Series General Specifications
-Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire
More informationXCMD2110L1 limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m
Characteristics limit switch XCMD - metal end plunger - 1NC +1NO - snap - 1 m Product availability : Stock - Normally stocked in distribution facility Price* : 43.90 USD Main Range of product OsiSense
More informationILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector
Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number
More information10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Characteristics
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationPLC-OPT-230UC/ 24DC/2
Extract from the online catalog PLC-OPT-230UC/ 24DC/2 Order No.: 2900368 PLC-INTERFACE, consisting of PLC-BPT basic terminal block with Push-in connection and plug-in miniature solid-state relay, for mounting
More informationInput Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection
(877) 634-0982 www.digipwr.com DPMULP40 Series 40 Watt Medical Grade AC/DC Power Supply Product Specification Universal AC Input 3 x 2 x 0.75 Footprint Key Product Features Medical (BF) Safety Approved
More informationILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A
Characteristics integrated drive ILS with stepper motor - 24..36V - I/O for motion sequence - 5A Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network
More informationMTA-156 IDC Quad Connectors
MT-156 IDC Quad Connectors MT-156 Product Facts Provides four points of contact Greater current carrying capability than Standard MT-156 Connectors Connector styles include both closed end and feedthru
More informationSwitching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W
Switching Power Supply Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Models range from 10 to 600 W UL 508 approval on 100-W 150-W, 300-W, and 600-W models Wide range of output
More informationKU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC
P& KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 mp 150VDC Load Switching KUMP 15 mp 2VC File E2255 File LR1534 0435 Registration 12 (KUIP) 0435
More informationCROWN LINE Power Bus Bar Distribution System
COWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System The pluggable bus bar system Currents up to 300 Amps Up to 2 meters in length Pluggable breakers VDE finger proof
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationElectrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)
225 Watt Industrial Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationAPG/UPG/IPG Series Existing Designs Only APG/UPG/IPG
APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Hydraulic Magnetic Circuit Protectors INTRODUCTION IMPORTANT NOTICE: The APG/UPG is a legacy product and no new design-in orders
More informationOverloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D
Circuit Protection Disconnect Switches Thermal Overload Relays n extended operational service life is one of the main features you can find in RW overload relays. WEG s RW Thermal Overload Relays are designed
More informationFerraz Shawmut TPMOV Principles and Operation
TPMOV Origin Due to recent changes in the Underwriters Laboratories Standard for Safety for Surge Protective Devices UL 1449 additional requirements have been instituted to maintain listings of Surge Protective
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationGeneral Specifications
Series M00 Tipped Toggles Toggles Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated P Pushbuttons Rockers General Specifications Electrical Capacity
More informationTerminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks
Series A3000, LP3000 & CB3000 Single Row Terminal SPECIFICATIONS Rating: A3: 30A, 600V* #12-22 AWG LP3: 30A, 150V #12-22 AWG CB3: 30A, 600V #12-22 AWG Wire Range: #12-22 AWG CU Center Spacing: 0.437 or
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationCABLE PROTECTORS /SPECIAL PURPOSE
CABLE PROTECTORS Ferraz Shawmut Cable Protectors are special purpose limiters which are crimped or bolted to cables to clear and isolate faults quickly, increasing the reliability of service entrance and
More informationMini-Universal MATE-N-LOK Connectors
MP Mini-Universal MTE-N-LOK Product Facts Compact, durable housings Pins and sockets can be accommodated in the same housings Contacts fully protected in the housings. Both pins and sockets can be used
More information60 Watt Medical (MWLT)
60 Watt Medical (MWLT) Features 4 x 2 x 1.2 inches Ultra high efficiency > 85% 50-65 W from 1 to 3 outputs Low leakage current < 250 µa Nemko, UL & CSA approvals to IEC60601 EN55022-B, CISPR22-B, FCC Part15
More informationS8VE (60/90/120/180/240-W Models)
Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,
More informationGeneral Specifications
Series M00 Tipped Toggles Toggles Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated P Pushbuttons Rockers General Specifications Electrical Capacity
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationPGA / BGA / PLCC SOCKETS
PGA / BGA / PLCC SOCKETS QUICK SELECTOR CHART PGA / BGA / PLCC PGA BGA PLCC GRID 2.54 mm INTERSTITIAL 1.27 mm 1.27 mm 1 mm SOCKETS Solder tail 156 161 165 SEE PAGE 173 Surface mount 156 161 165 166 169
More informationElectronic timer CT-ERS.21
2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width
More informationSafety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths
DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product
More information9926 Series Branch Rated Circuit Breakers AC Version
Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationIEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton
K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration
More informationLFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00
Features 5 x 3 x 1 Inches Form factor 350 Watts with Forced Air Cooling & 200 Watts Convection Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down
More informationSPXI SERIES IN-LINE SOLAR FUSE
00 Vdc.-0 A Description The Littelfuse SPXI solar fuse is designed to integrate into an in-line assembly within a wire harness. The fuse provides photovoltaic (PV) protection that meets UL - for photovoltaic
More informationMEDIUM VOLTAGE FUSES. POWR-GARD Fuse Datasheet. 2,400-38,000 VAC Current-Limiting
MEDIUM VOLTAGE FUSES 2,400-38,000 VAC Current-Limiting Current-limiting E- and R-rated fuses are equipped with a mechanical indicator or striker pin that protrudes through the fuse cap upon operation of
More informationKU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 Amp 150VDC Load Switching KUMP 15 Amp 277VAC
KU series KUP Enclosed Relay KUIP VDE 8mm Coil to Contacts KUGP VDE 8mm 3mm Gap Coil to Contacts KUEP 10 mp 150VDC Load Switching KUMP 15 mp 2VC File E2255 File LR1534 0435 Registration 12 (KUIP) 0435
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationLFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00
Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Approval to EN60601 3 rd Edition Efficiencies upto 94% -40 to 70 degree operating temperature* Dual fusing 12V / 0.5A Fan Output,
More informationMicroswitches MS Series
General purpose microswitches for heavier duty applications High precision snap action mechanism 16A 250V AC resistive rating (I th ) Wide range of actuator styles Screw terminals with self lifting plate
More informationElectrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)
WLP350 Industrial Features 5 x 3 x 1 Inches Form factor 350 Watts with Forced Air Cooling & 200 Watts Convection Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output,
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationMini-Universal MATE-N-LOK 2 Connectors
MP Mini-Universal MTE-N-LOK 2 Product Facts One molded piece, secondary locking plug and cap housing assemblies Three-point stabilization to provide better terminal position Fully polarized to provide
More informationAC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series
AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, 230-310 WATTS MEDICAL APPLICATIONS MUI310-A Series 2MOPP Medical FEATURES Universal Input Range 4000Vac Input/Output Isolation 2 X MOPP Class l Protection
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet
2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication
More informationElectrical Components Catalog Universal MATE-N-LOK Connector System
Introduction Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification Contacts completely enclosed in housings Positive locking housings Insulation
More informationCOOPER POWER SERIES. Fusing Equipment Catalog Data CA132064EN. Effective February 2018 Supersedes January 2014 (240-50)
Fusing Equipment Catalog Data CA132064EN Supersedes January 2014 (240-50) COOPER POWER SERIES Table of contents Attention....3 Eaton is in the process of updating part numbers and technical data due to
More informationC 2 5 D N A A A
Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationDistributed by: www.jameco.com -800-8-44 The content and copyrights of the attached material are the property of its owner. Pin and Socket Mini-Universal MTE-N-LOK Product Facts Compact, durable housings
More informationModular plugs, accessories and tooling
Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for
More informationThe PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC
The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationHeavy Duty Terminal Blocks
General Information: are available in two styles Deadfront Type (1100, 1200, 985 and 0987 series) and Barrier Type (1500, 1600 and 1700 series). Ratings and Standards: The voltage ratings of terminal blocks
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More information