Multifunction transmitter C 310
|
|
- Rafe Lang
- 5 years ago
- Views:
Transcription
1 Multifunction transmitter C 310 KEY POITS 2 inputs for interchangeable probes 1 location for interchangeable SPI-2 board Simultaneous display of 1 to 4 parameters Trend indicator 4 visual (dual-color EDs) and audible alarms 2 analogue outputs (4 wires) 0/5-10 V or 0/4-20 ma, 2 additional outputs 4-relay board 24 Vdc/Vac or 115/230 Vac power supply Outputs diagnostic Ethernet communication MODBUS network RS485 system ABS housing with stainless steel front, IP65, with or without backlit graphic display ¼ turn system mounting with wall-mount plate FEATURES OF THE HOUSIG 158 mm 81 mm Material: ABS V0 as per U94 Protection: IP mm Display: Graphic from 1 to 4 lines, 240 x 128 px; Size: 86 x 51 mm, Backlit Height of digits: Values: 10 mm; Units: 5 mm Cable gland: in polyamide for cables Ø9 mm maximum 25 mm Weight: 700 g PART UMBERS C310-BO : multifunction transmitter, 24 Vac/Vdc power supply, with display C310-B : multifunction transmitter, 24 Vac/Vdc power supply, without display C310-HO : multifunction transmitter, Vac power supply, with display C310-H : multifunction transmitter, Vac power supply, without display TECHICA SPECIFICATIOS Power supply Outputs Galvanic isolation Consumption with probe and without option Relays European directives Electrical connections RS485 communication Ethernet communication 24 Vac / Vdc ±10% Vac, Hz Warning: risk of electric shock 2 x 0/4-20 ma or 2 x 0-5/10 V (4 wires) Optional additional outputs: 2 x 0/4-20 ma or 2 x 0-5/10 V (additional consumption for 24 V model: 1 VA / for V model: 2 VA) Common mode voltage <30 VAC Maximum load: 500 Ohms (0/4-20 ma) / Minimum load: 1 K Ohms (0-5/10 V) Inputs (power supply) and outputs (on 115 Vac/230 Vac models) Device fully protected by DOUBE ISOATIO or REIFORCED ISOATIO Outputs (on 24 Vac/Vdc models) C310-BO and C310-B: 6 VA C310-HO and C310-H: 8 VA (CO2 probe additional consumption for 24 V and V models: 2 VA) 4 RCR relays 5 A / 230 V (additional consumption for 24 V model: 5 VA / for V model: 8 VA) 2014/30/EU EMC; 2014/35/EU ow Voltage; 2011/65/EU RoHS II; 2012/19/EU WEEE Screw terminal block for cables from 0.05 to 2.5 mm 2 or from 30 to 14 AWG Carried out according to the code of good practice Digital: Modbus RTU protocol, configurable communication speed from 2400 to Bauds Ethernet communication module allowing transmission, monitoring and maintenance of transmitters via an Ethernet network in 10 BASE-T and 100 BASE-TX A/WA supporting TCP/IP protocol (additional consumption for 24 V and V models: 1 VA)
2 TECHICA SPECIFICATIOS Audible alarm Buzzer (70 db at 10 cm) Environment and type of fluid Air and neutral gases Conditions of use ( C/%RH/m) From -10 to +50 C. In non-condensing condition. From 0 to 2000 m Storage temperature From -10 to +70 C Security Protection class 2; Pollution degree 2; Overvoltage category 2 REAYS AD AARMS The C 310 transmitter has 4 independent and configurable alarms : these are visual and audible alarms and it is possible to couple them with 4 relays. Available settings: Selection of the parameter (pressure, air velocity, temperature,...) Time-delays duration from 0 to 600 s Alarm action : rising edge, falling edge, monitoring or state of the transmitter Operating mode of the relays : negative or positive safety Activation of the audible alarm (buzzer) that can be acknowledged by the front keypad COECTIOS Solenoid valve SPI-2 board Autozero RS 485 connection(d) Analogue outputs (a) (OUT3 and OUT4 are optional) CC-S software connection Relays board (b) Power supply terminal block (c) Pressure connection (a) Probes connection Ethernet board Cable glands (b) Type of power supply of the transmitter Analogue output 1 (OUT1) Analogue output 2 (OUT2) Analogue output 3 (OUT3) Optional Analogue output 4 (OUT4) Relay 1 Relay 2 Relay 3 Relay 4 0/4-20 ma Current GD Ground 0-5/10 V - Voltage 0/4-20 ma Current GD Ground 0-5/10 V - Voltage 0/4-20 ma Current GD Ground 0-5/10 V - Voltage 0/4-20 ma Current GD Ground 0-5/10 V - Voltage O : ormally open COM : Common C : ormally closed O : ormally open COM : Common C : ormally closed O : ormally open COM : Common C : ormally closed O : ormally open COM : Common C : ormally closed (c) For 24 Vdc/Vac power supply models: or (c) For 115 Vac or 230 Vac power supply models: (d) Modbus: Operational grounding eutral () - Phase () + Operational grounding eutral ()~ Phase ()~ GD A + B -
3 EECTRICA COECTIOS as per FC orm This connection must be made by a formed and qualified technician. Whilst making the connection, the transmitter must not be energized. The presence of a switch or a circuit breaker upstream the device is compulsory. For 24 Vdc power supply models: For 115 Vac or 230 Vac power supply models: Vdc power supply 115/230 Vac power supply For 24 Vac power supply models: or 230 Vac Pe 24 Vac power supply class II 24 Vac 230 Vac Pe 24 Vac power supply 24 Vac 0/4-20 ma current output connection: 0/4-20 ma 0-5/10 V GD 0-5/10 V voltage output connection: 0/4-20 ma 0-5/10 V GD + Regulator display or PC/BMS passive type Regulator display or PC/BMS passive type POSSIBE OPTIOA MEASUREMETS The following probes and boards are available as option for C310 transmitters. For further details please see the technical datasheet of probes for class 310 transmitters. Probes Stainless steel or polycarbonate hygrometry / temperature probe Air velocity vane probe: air velocity / temperature / airflow Air velocity hotwire probe: air velocity / temperature / airflow From 0 to 100%RH and from -40 to +180 C (according to probe) From -5 to 35 m/s (according to probe) / From -20 to +80 C / From 0 to m³/h From 0 to 30 m/s / From -20 to +80 C / from 0 to m³/h Omnidirectional probe: air velocity / temperature From 0 to 5 m/s and from 0 to 50 C Pt100 1/3 DI temperature probe From -50 to +180 C / From -20 to +80 C CO / temperature probe From 0 to 500 ppm and from 0 to 50 C CO 2 / temperature probe From 0 to ppm and from 0 to 50 C Pressure / atmospheric pressure Relays Boards From -100 to Pa (according to boards) / from 800 to 1100 hpa 4 relays 3 A with 3-point terminal blocks RS 485 MODBUS PROTOCO Class 310 transmitters can be linked in one network operating on a RS485 home bus. The RS 485 digital communication is a 2-wire network, on which the transmitters are connected in parallel. They are connected to a PC/BMS via the RTU Modbus communication system. Since the C310 can be configured with the keypad, the MODBUS enables remote configuration, to measure 1 or 2 parameters or to see the status of the alarms...
4 ETHERET BOARD An Ethernet board can put put on a C310 transmitter allowing for each transmitter to have a specific configurable IP address. So the user can remotely interrogate the transmitter, retrieve data, modify the configuration,... It is also possible to integrate C310 transmitters into a computer network via the RJ45 connection located at the bottom of the transmitter. COFIGURATIO Class 310 transmitters allows you to set all the parameters managed by the transmitter : units, measuring ranges, alarms, outputs, channels... via the different methods shown below: Via keypad, only on models with display. A code-locking system for keypad guarantees the security of the installation. See configuration manual. Via software : simple and user-friendly. See CC-S user manual. Via Modbus : configuration of all parameters from your PC, via the supervision or data acquisition software. Via Ethernet : configuration of all parameters from your PC, via the supervision or data acquisition software. MOUTIG To install the transmitter on a wall, fix the stainless steel plate to the wall (drilling: Ø8 mm, screws and wall-plugs supplied). Insert the transmitter on the plate (see A on the drawing below) by aligning it at 30. Rotate the housing in clockwise direction until you heard a click which confirms that the transmitter is correctly installed. Open the housing, lock the clamping system of the housing on the plate with the screw (see photo below). To remove the transmitter from the fixing plate, do not forget to remove this screw. A CAIBRATIO Outputs diagnostics: with this function, you can check with a multimeter (or on a regulator/display, or on a PC/BMS) if the transmitter outputs work properly. The transmitter generates a voltage of 0 V, 5 V and 10 V or a current of 0 ma, 4 ma, 12 ma and 20 ma Certificate: transmitters are supplied with an individual adjusting certificate and can be supplied with a calibration certificate as an option. MAITEACE OPTIOS 120 mm 65 mm A 316 stainless steel plate 65 mm 98 mm Ø 5,4 mm Avoid aggressive solvents. When cleaning rooms or ducts with products containing formol, protect the the transmitter. CC-S: configuration software with USB cable SQR/3 function: (square root extraction) function for the calculation of air velocity and airflow RS5: RS 485 Protocol Modbus digital output O2S: 2 additional analogue output C4R: 4 relays board CETHE: Ethernet network board HRP: high resolution (example in pressure: 0.1 Pa) with SPI2-100 board Calibration certificate Only the accessories supplied with the device must be used. PRECAUTIOS FOR USE Fixing screw of the housing Please always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the device. FTang C310 27/01/2017 RCS (24) Périgueux on-contractual document We reserve the right to modify the characteristics of our products without prior notice. Once returned to KIMO, required waste collection will be assured in the respect of the environment in accordance with European guidelines relating to WEEE.
5 Probes and interchangeable boards for class 310 sensors Ambient hygrometry/temperature probes... 1 Stainless steel hygrometry/temperature probes... 1 Remote hygrometry/temperature probes... 2 Stainless steel hygrometry/temperature probes Polycarbonate hygrometry/temperature probes Temperature probes...3 CO 2 /temperature probes and CO/temperature... 4 Air velocity probes and temperature... 4 Ø14 mm vane probe...4 Ø70 mm vane probe...5 Ø100 mm vane probe...5 Hot-wire probe... 5 Omnidirectional probe...6 Extensions for probes... 6 Interchangeable boards... 6 Pressure boards... 6 Current/Voltage boards...7 AMBIET HYGROMETRY/TEMPERATURE PROBES Stainless steel hygrometry/temperature probes Interchangeable hygrometry and ambient temperature probe in stainless steel with stainless steel filter. Standard mounting probe 120 mm length with a watertight connector of 1/4 turn. In option: protective tips, filters. Supplied with adjustment certificate. Ref: SHSI 74.5 mm mm Parameter Measuring range Temperature Pt100 ( C, F) From -20 to +80 C ±0.3% of reading ±0.25 C Wet temperature 1 ( C tw, F tw ) From -50 to 100 C tw - tw Dewpoint 1 ( C td, F td ) From -50 to +100 C td - td Relative humidity (%RH) From 0 to 100%HR Hygrometry: - Accuracy (Repeatability, linearity, hysteresis): ±1.5%RH (from 15 C to 25 C and from 5 to 95%RH) - Factory calibration uncertainty: ±0.88%RH - Temperature dependence: ±0.04 x (T-20) %RH (if T<15 C or T>25 C) 0.1%RH Absolute humidity 1 (g/m 3 ) From 0 to 600 g/m g/m 3 Enthalpy 1 (kj/kg) Combination ration 1 (g/kg) C310/CA310: from 0 to kj/kg CPE310: from 0 to 9999 kj/kg - C310/CA310: from 0 to : 0.1 kj/kg from to : 1 kj/kg CPE310: from 0 to 999.9: 0.1 kj/kg from 1000 to 9999: 1 kj/kg 1 Calculated value C310: from 0 to g/kg CA310: from 0 to g/kg CPE310: from 0 to 9999 g/kg - C310/CA310: 0.1 g/kg CPE310: from 0 to g/kg: 0.1 g/kg from 1000 to 9999 g/kg: 1 g/kg 1
6 REMOTE HYGROMETRY/TEMPERATURE PROBES Stainless steel hygrometry/temperature probes Interchangeable hygrometry and temperature probe in stainless steel with stainless steel filter. Remote probe 150 mm length or 300 mm, diameter. White silicone cable 2 m length with watertight connector 1/4 turn. In option : protection socket, filters. Supplied with adjustment certificate. Ref: SHDI-150 (probe 150 mm length) SHDI-300 (probe 300 mm length) 151 mm or 301 mm 165 mm or 315 mm Polycarbonate hygrometry / temperature probe Interchangeable hygrometry and temperature probe in polycarbonate with stainless steel filter. Remote probe 150 mm length or 300 mm, diameter. White silicone cable 2 m length with watertight connector 1/4 turn. In option : protective tips, filters. Supplied with adjustment certificate. Ref: SHDP-150 (probe 150 mm length) SDHP-300 (probe 300 mm length) 150 mm or 300 mm mm or mm Parameter Measuring range Temperature Pt100 ( C, F) From -20 to +80 C ±0.3% of reading ±0.25 C Wet temperature 1 ( C tw, F tw ) From -50 to 100 C tw - tw Dewpoint 1 ( C td, F td ) From -50 to +100 C td ±0.6% of reading ±0.5 C td td Relative humidity (%RH) From 0 to 100%HR Hygrometry: - Accuracy (Repeatability, linearity, hysteresis): ±1.5%RH (from 15 C to 25 C and from 5 to 95%RH) - Factory calibration uncertainty: ±0.88 %RH - Temperature dependence: ±0.04 x (T-20) %RH (if T<15 C or T>25 C) 0.1%RH Absolute humidity 1 (g/m 3 ) From 0 to 600 g/m g/m 3 Enthalpy 1 (kj/kg) Combination ration 1 (g/kg) C310/CA310: from 0 to kj/kg CPE310: from 0 to 9999 kj/kg C310: from 0 to g/kg CA310: from 0 to g/kg CPE310: from 0 to 9999 g/kg - C310/CA310: from 0 to : 0.1 kj/kg from to : 1 kj/kg CPE310: from 0 to 999.9: 0.1 kj/kg from 1000 to 9999: 1 kj/kg - C310/CA310: 0.1 g/kg CPE310: from 0 to g/kg: 0.1 g/kg from 1000 to 9999 g/kg: 1 g/kg 1 Calculated value 2
7 6 mm TEMPERATURE PROBES Interchangeable temperature probe Pt100 1/3 DI of general use, contact tip 6 mm diameter, 150 mm length, IP65. Grey silicone cable 2 m length with watertight connector 1/4 turn. Supplied with adjustment certificate. Ref: STD mm From -50 to +180 C ±0.3% reading ±0.25 C Interchangeable temperature probe of general use Pt100, 1/3 DI type STS-13, contact tip 6 mm diameter, 22 mm length. Range from -20 to +80 C. Direct output on connector for C310 sensors, CPE310 (with adapter) and large display CA310. Supplied with adjustment certificate. Ref: STS mm mm 6 mm From -20 to +80 C ±0.3% reading ±0.25 C Interchangeable adapter for 3-wire Pt100 temperature probe. Allows to plug a 3-wire Pt100 probe to a class 310 sensor. PVC cable, 10 cm length with connector 1/4 turn and 3-point terminal to screw for Pt100 wires output probe. Ref: STA-13 G ' Measuring range According to the probe (maximum measuring range in temperature: from -100 to 400 C) According to the probe 3
8 26 mm 14 mm CO 2 PROBES / TEMPERATURE AD CO/TEMPERATURE Interchangeable CO 2 and temperature probe or CO and temperature in ABS V0. Remote probe 160 mm length, 26 mm diameter. White PVC cable 2 m length with watertight connector 1/4 turn. Supplied with mounting flange and adjustment certificate. Ref: SCO2 / SCCO mm 183 mm 144 mm CO2 Probe temperature CO Probe temperature From 0 to 5000 ppm and from 0 to 50 C (other range available in CO 2 : from 0 to ppm) CO 2 : from 0 to 5000 ppm : ±3% of the reading ±50ppm from 0 to ppm : ±5% of the reading ±100 ppm Temperature CT : ±0.3 C 0.1 ppm From 0 to 500 ppm and from 0 to 50 C CO: ±3 ppm or 3% of the measured value Temperature CT: ±0.3 C 0.1 ppm AIR VEOCITY AD TEMPERATURE PROBES SVH-14 : Ø14 mm vane probe Interchangeable air velocity and temperature remote with Ø14 mm vane, 300 mm length, white PVC cable 2 m length with watertight connector 1/4 turn. 253 mm 312 mm From 0 to 25 m/s From -20 to +80 C From 0 to m 3 /h Air velocity: from 0.8 to 3 m/s : ±3% of the reading ±0.1 m/s from 3.1 to 25 m/s : ±1% of the reading ±0.3 m/s Temperature Pt100: ± 0.4% reading ± 0.3 C Flow : ± 3% reading or ± 0.03* sheath surface (cm 2 ) 0.1 m/s 0.1 m 3 /h 4
9 77.2 mm mm 8.6 mm 8 mm SVH-70 : Ø70 mm vane probe Interchangeable air velocity and temperature remote probe with Ø 70 mm vane, 200 mm length, white PVC cable 2 m length with watertight connector 1/4 turn. 200 mm From -5 to 35 m/s From -20 to +80 C From 0 to m 3 /h 0.1 m/s / 0.1 C / 0.1 m 3 /h mm SVH-100 : probe Ø100 mm wind vane Air velocity: from 0.4 to 3 m/s: ±3% of the reading ±0.1 m/s from 3.1 to 35 m/s: ±1% of the reading ±0.3 m/s Temperature Pt100: ± 0.4% reading ± 0.3 C Flow: ± 3% reading or ± 0.03* sheath surface (cm 2 ) Interchangeable air velocity and temperature remote probe with Ø 100 mm vane, 200 mm length, white PVC cable 2 m length with watertight connector 1/4 turn. 200 mm m From -5 to 35 m/s From -20 to +80 C From 0 to m 3 /h Air velocity: from 0.3 to 3 m/s: ±3% of the reading ±0.1m/s from 3.1 to 35 m/s: ±1% of the reading ±0.3 m/s Temperature Pt100: ± 0.4% reading ± 0.3C Flow: ± 3% reading or ± 0.03* sheath surface (cm 2 ) From -5 to -3 m/s: 0.1 m/s; from -3 to 3 m/s: 0.01 m/s; from 3 to 35 m/s: 0.1 m/s 0.1 C 0.1 m 3 /h SVS : hot-wire probe Interchangeable air velocity and temperature remote hot-wire probe in stainless steel 300 mm length, 8 mm diameter, white PVC cable 2 m length with watertight connector 1/4 turn. 282 mm From 0 to 30 m/s From -20 to +80 C From 0 to m 3 /h Air velocity: from 0 to 3 m/s: ±3% of the reading ±0.03 m/s from 3.1 to 30 m/ : ±3% of the reading ±0.1 m/s Temperature Pt100: ± 0.3% reading ± 0.25 C Flow: ± 3% reading or ± 0.03* sheath surface (cm 2 ) From 0 to 3 m/s: 0.01 m/s; from 3 to 30 m/s: 0.1 m/s 0.1 C 0.1 m 3 /h 5
10 81 mm 8 mm SVO : omnidirectional probe Interchangeable air velocity and temperature remote omnidirectional hot-wire probe in stainless steel 300 mm length, 8mm diameter, white PVC cable 2 m length with watertight connector 1/4 turn. Supplied with carrying case and tripod. 364 mm EXTESIOS FOR PROBES From 0 to 5 m/s From 0 to +50 C Air velocity: ± 3% reading ± 0.05 m/s Temperature Pt100 1/3 DI: ± 0.3% reading ± 0.25 C 0.01 m/s 0.1 C R310-5: Extension of 5 m for interchangeable probes class 310 R310-10: Extension of 10 m for interchangeable probes class 310 ITERCHAGEABE BOARDS Pressure boards SPI-2 Interchangeable pressure board with electro-valve and terminal for K thermocouple probe for C310 and CA310 sensors. Supplied with pressure fitting and silicone tubes. Ref: SPI2-100 SPI2-500 SPI SPI Pressure Admissible removal Units and resolution SPI2-100: from -100 to +100 Pa SPI2-500: from -500 to +500 Pa SPI2-1000: from to Pa SPI : from to Pa SPI2-100: ±0.2% of the reading ±0.8Pa SPI2-500: ±0.2% of the reading ±2Pa SPI2-1000: ±0.2% of the reading ±2Pa SPI : ±0.2% of the reading ±10Pa SPI2-100 / SPI2-500 / SPI2-1000: Pa SPI : Pa 1 Pa 0.1 mmh 2 O 0.01 mbar 0.01 inwg 0.01 mmhg 0.1daPa kpa 0.01 hpa Temperature K thermocouple From -200 to C (according to the probe) ±1.1 C or ±0.4% of the read value 1 Units and resolution 0.1 C 0.1 F 1 The accuracy is expressed by a gap in C, or by a percentage of the read value. Only the bigger value is held. 6
11 These pressure boards SPI2 for C310 and CA310 sensors have a temperature compensation of the gain from 0 to 50 C and an auto-calibration process which guarantee over time an excellent stability and a perfect reliability of the measurement as much in low as high range. Auto-calibration principle : the microchip of the sensor manages an electro-valve which compensates possible remotes of the sensitive element over time. The compensation is insured by a permanent adjustment of the zero. The differential pressure measurement is then independent from the environmental conditions of the sensor. Electro-valve lifetime: 100 millions of cycles Advantage: no zero remote Periodicity of the auto-calibration: detachable or from 1 to 60 min. Terminal for K thermocouple probe Example of SPI2 pressure board on C310 sensor Relay board C4R on C310 sensor Interchangeable atmospheric pressure board for C310 and CA310 sensors, range hpa. Supplied with pressure fitting and silicone tube. Ref: SPI2-ATMO Units and resolution From 800 to 1100 hpa ±2 hpa 0.1mbar 0.1mmHG 0.1hPa Current / Voltage boards Interchangeable board, 3 current / voltage analogic input: 0-20 ma / 4-20 ma et 0-2,5 V / 0-5 V / 0-10 V, with terminal, CA310 sensor. Ref: MVA 0 20 ma 4 20 ma V 0 5 V 0 10 V 0 20 ma : ± 0.01 ma 4 20 ma: ± 0.01 ma V: ± V 0 5 V: ± V 0 10 V: ± V Example of MVA current / voltage board on CA310 sensor 7
PTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationKISTOCK DATALOGGER KT 220 / KH 220 / KTT 220
KISTOCK DATALOGGER KT 220 / KH 220 / KTT 220 / Humidity / Light / Current Voltage / Impulsion / Water pressure KEY POINTS Available with or without display Software for configuration and data visualisation
More informationInput for universal probe* Inputs for thermocouple probes
Device reference Display Internal sensor External sensor Number Type Number Type Parameters Number of record points KT 220 - O KT 220 - N KH 220 - O KH 220 - N Yes No Yes No 1 Temperature 3 Temperature,
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters
More informationEE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)
is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates
More informationKISTOCK DATALOGGER KT 320 / KTT 320
KISTOCK DATALOGGER KT 30 / KTT 30 / Humidity / Voltage/ Current / Impulsion KEY POINTS Software for configuration and data visualisation freely downloadable Software for configuration and data processing
More informationThe industrial humidity transmitter
The industrial humidity transmitter + probe series testo 661x Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs allow
More informationEE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310
High-End Humidity and Temperature Transmitter for Demanding Process Control is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative
More informationIn order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.
Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity
More informationThe industrial humidity transmitter
The industrial humidity transmitter + probe series testo 661x Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs
More informationMultifunction instrument AMI 310
Multifunction instrument AMI 310 Table of contents 1 Presentation...6 1.1 Instrument description...6 1.2 Remove battery...7 1.3 Insert SD card...7 2 Connections of the AMI310...8 2.1 Main features...8
More informationactoolsupply.com MP 200 Manometer Calibration certificate Supplied with actoolsupply.com
Supplied with Calibration certificate MP 200 Manometer Kimo MP 200 P Thermo Anemometer Manometer Kimo MP 200 M Thermo Anemometer Manometer Kimo MP 200 G Thermo Anemometer Manometer Kimo MP 200 H Thermo
More informationClass 220 KISTOCK. KT 220, KH 220 and KTT 220
Class 220 KISTOCK KT 220, KH 220 and KTT 220 Table of contents 1 Safety instructions...4 1.1 Precautions for use...4 1.2 Symbols used...4 2 Presentation of the device...5 2.1 Use...5 2.2 Applications...5
More informationDMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions
www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew
More informationDP DP2500 DP0250
DP7000 - DP2500 DP0250 PB_DP7000_DP2500 - DP0250_07 2016 Field adjustable, multi-range differential pressure transmitters Product Bulletin The Delta Pressure transmitter series of Johnson Controls, with
More informationGeneral Catalogue. Export Pressure Temperature Humidity Air velocity Airflow Air quality Sound level
General Catalogue Export 2009 Pressure Air velocity Airflow Air quality Sound level Pressure Air Velocity Airflow Tachometry Air Quality F C Wireless probes New Special air quality CO CO ² Portable New
More informationDP2500 DP0250. Differential Pressure Transmitter. Product Bulletin
DP2500 DP0250 Differential Pressure Transmitter Product Bulletin The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air and
More informationHLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.
Series The precise and reliable measurement of humidity in industrial processes is gaining more and more importance. The multifunctional transmitters series offer the ideal solution. The result of many
More informationHumidity transmitter for critical climate applications
Humidity transmitter for critical climate applications testo 6651 Optimum adjustment concept thanks to adjustability of the entire signal chain incl. analog adjustment Ethernet, relay and analog outputs
More informationtesto Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x
+ Probe series testo 661x SPECIFICATIONS Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment Profibus, Ethernet, relay and analog outputs allow optimum integration
More informationDXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions
DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL
More informationSupplied with. Calibration certificate. HD 200 Hygrometer
Supplied with Calibration certificate HD 200 Hygrometer Table of contents 3 I Technical specifications...4 Technical features......4 Specifications......4 II Introduction......5 Description......5 Connections......6
More informationDual differential pressure sensor For ventilation and air-conditioning Model A2G-52
Pressure Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52 WIKA data sheet PE 88.03 for further approvals see page 5 Applications For monitoring air, non-inflammable and
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationPrecision digital measuring device PHYSICS 51
Precision digital measuring device PHYSICS 51 Digital measuring device for thermocouples, NTC resistance thermometers, infrared temperature probes, capacitive humidity probes. Technical data PHYSICS 51
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationEE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211
Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding
More informationPS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters
PS-AULDP Series Datasheet Ultra Low Air Differential Pressure Transmitters Overview The PS-AULDP Series are ultra-low-pressure transmitters. These devices can be used to measure differential pressure between
More informationInCos-P Pressure sensor 20 Pa Pa
InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.
More informationInBin-P Pressure switches from 5 Pa Pa
InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact
More informationOutput Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W
Duct Sensor Humidity / Temperature For measuring the relative or absolute humidity and temperature in duct applications. The measured values and absolute humidity, dewpoint and enthalpy are transmitted
More informationHPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions
DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL
More informationOutput signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W
Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X
More informationEE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210
Humidity and Temperature Transmitter for Demanding Climate Control The transmitter by E+E Elektronik meets the highest requirements in demanding climate control applications. Besides the accurate measurement
More informationTemperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual
Temperature and humidity regulator H3020 H3021 H3023 H3027 Instruction Manual Table of content 1. GENERAL SAFETY RULES... 3 2. GENERAL DESCRIPTION... 4 3. REGULATOR MOUNTING AND CONNECTION... 4 4. DESCRIPTION
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control
More informationMultifunction instrument AMI 310
Multifunction instrument AMI 310 Table of contents 1 Presentation...6 1.1 Instrument description...6 1.2 Remove battery...7 1.3 Insert SD card...7 2 Connections of the AMI310...8 2.1 Main features...8
More informationDSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationLCC-S Configuration software for transmitters
LCC-S Configuration software for transmitters Table of contents 1. Introduction...5 2. Software installation...5 2.1. Minimum system requirement...5 2.2. Installing the software...5 3. Start with the
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationMulti-Point Gas Detection and Control System
Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and
More informationCAEL-DP Series Dew Point Transmitter for Industrial Control
CAEL-DP Series Dew Point Transmitter for Industrial Control SERIAL's latest CAEL series Dew Point transmitter meets the harsh environmental requirements for Dew Point measurement. Via temperature and relative
More informationHMT330 Series Humidity and Temperature Transmitters for Industrial Applications
HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial
More information14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page
Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03
More informationCALYS 50. Field multifunction calibrator for basic use. Calibration measurement
for basic use Description is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field
More informationIMIO100 IMIO105. DDC controllers. Summary
IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one
More informationOutput Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W
Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the
More informationPlease Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT
Installation and Operation Instructions A/CO2-DUCT Series Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT PRECAUTIONS REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT
More informationSupplied with. Calibration certificate. TM 200 Thermometer
Supplied with Calibration certificate TM 200 Thermometer Table of contents 3 I Technical specifications...4 Technical features...4 Specifications...4 II Introduction...5 Description...5 Connections...6
More informationDigital pressure gauge Data Sheet: DMM2.431.R1.EN
Data Sheet: DMM.431.R1.EN www.aep.it Digital pressure gauge DMM is a digital pressure gauge made according to the most modern technologies to ensure a high level of reliability, versatility and practicality
More informationHumidity goes Digital
Industrial Humidity Temperature Transmitter Dew-point and other calculated values Wide range of digital interchangeable probes No need for field calibration PC compatible and RS485 networkable SWISS MADE
More informationHD B. [ GB ] Precision Barometer
HD 9408.3B [ GB ] Precision Barometer [ GB ] [ GB ] Characteristics High accuracy temperature-compensated sensor with excellent stability Wide temperature operating range Various output options available
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual
T0210 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0210 transmitter
More informationMulti Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual
Multi Units Humidity/Temperature Transmitter HygroViewer Model JW300 User Manual 1. Electrical Wired & Installation The power cord is a one-meter length, 22 AWG, 7 different colors for recognition. Please
More informationsensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.
USER S GUIDE EE800 - HVAC Room Transmitter for CO 2, Temperature and Relative Humidity GENERAL EE800 combines CO 2, temperature (T) and relative humidity (RH) measurement in one device with modern design.
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationUC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display
UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationVaisala HUMICAP Structural Humidity Measurement Kit SHM40. Full SHM40 product presentation and introduction to the borehole method
Vaisala HUMICAP Structural Humidity Measurement Kit SHM40 Full SHM40 product presentation and introduction to the borehole method SHM40 a starter kit ideal for the borehole method Practical tool for humidity
More informationMPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationTable of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION
Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationFTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist
FTM84/85 Feature Application IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation Llinear adjustment air velocity by computer, analogue output
More informationDIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module
DIFFERENTIAL RESSURE TRANSMITTER with MODBUS interface Optional Input module DT-MOD (-IN) Summary Each device is individually temperature compensated. Type name (-IN for Input module) (-AZ for autozero)
More informationMMT330 Series Moisture and Temperature Transmitters for Oil
MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationMXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function
MXIO Compact I/O module Summary The MXIO multiple I/O compact module is a microprocessor-controlled, communicative module with the I/O mix optimized for larger HVAC control applications. The module uses
More informationPHYSICS Digital Measuring Devices
PHYSICS Digital Measuring Devices For precise measurements in meteorology, chemical, pharmaceutical and food industries, biotechnology, water analytics, science and research as well as industrial quality
More informationOutput Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W
Duct Sensor CO₂ / Humidity / Temperature Duct air quality sensor for combined detection of CO₂, relative humidity and temperature. Designed for control and monitoring applications. Type Overview Type Output
More informationDifferential pressure sensor For ventilation and air-conditioning Model A2G-50
Electronic pressure measurement Differential pressure sensor For ventilation and air-conditioning Model A2G-50 WIKA data sheet PE 88.02 for further approvals see page 5 Applications For measuring differential
More informationInstruction Manual. T3110 T3110L T3110Ex
www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,
More informationEE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical
EE80 Series HVAC Room Transmitter and Switches for, Relative Humidity and Temperature EE80 series set new standards in measurements for HVAC. The transmitters resp. switches combine, relative humidity
More informationwith serial RS485/RS232 output
with serial RS485/RS232 output RS485 programmable sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs industry and interior design high quality, accurate
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationMP 210. Thermo-Anemo-Manometer
MP 210 Thermo-Anemo-Manometer Table of contents 1. Presentation...5 1.1 Instrument description...5 1.2 Keys description...5 1.3 Remove battery...6 2. Connections of the MP210...7 2.1 Main features...7
More informationCLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.
CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/
More informationSupplied with. Calibration certificate. Anemometer VT 200
Supplied with Calibration certificate Anemometer VT 200 Table of contents 3 I Technical specifications...4 Technical features......4 Specifications......4 II Introduction......5 Description......5 Connections......6
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationCarbon Monoxide (CO) Gas Detection and Control System
Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature
More informationGas Controller System DGC-06
Page 1 May 2016 Measuring, warning and controlling device series for toxic, combustible and refrigerant gases and vapours. The gas controller series DGC-06 is designed in accordance with the standard EN
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationINTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE
INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE In times where energy conservation is a top priority for all progressive enterprises, the measurement of flow rates and consumption is becoming more and
More informationwith serial RS485/RS232 output
with serial RS485/RS232 output RS485 programmable sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs industry and interior design high quality, accurate
More informationCDD4 Duct Carbon Dioxide Transmitter
Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationCLEAN ROOM PANEL - CRP5
RELIABLE MEASUREMENTS IN CLEAN ROOMS Measures differential pressure, humidity and temperature Designed specifically for clean rooms Removable humidity and temperature probes for simpler adjustment and
More informationDTM Distributed Transmitter Monitor
Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration
More informationInsertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )
The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed
More informationInReg Volume flow controller Pa
InReg Volume flow controller 0...300 Pa Electrical volume flow controller (CAV / VAV) for use in safe areas 24 VAC / DC supply, adaptive PID controller, alarm contact InReg - V... InReg - V... - A InReg
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationT3311, T3313, T3411 T7310, T7410. Instruction Manual
Programmable transmitter of temperature, relative humidity and other derived humidity values T3311, T3313, T3411 Programmable transmitter of atmospheric pressure, temperature, relative humidity and other
More informationProgrammable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual
TRANSMITTER T3413, T3417 Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual Instruction Manual for use of temperature
More informationMultifunction AMI 300
Supplied with Calibration certificate Multifunction AMI 300 P a Table of contents 3 I Technical specifications...4 Technical features...4 Specifications...4 II Introduction...6 Description...6 Connections...7
More informationProgrammable controller MCX152V
MAKIG MODER IVIG POSSIBE Technical brochure Programmable controller MCX152V MCX152V is a standard MCX electronic controller that stands on the top of MCX range thanks to its large number of input and output
More informationMXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.
MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process
More informationON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)
(ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications
More informationSensor for car parks and tunnels
Page 1 Sep. 2017 system with exchangeable sensor element including digital value processing, temperature compensation and selfmonitoring algorithm for the continuous sensing and control of the ambient
More informationaccurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service
Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet
More information