Chore-Tronics IDM Board Instruction

Size: px
Start display at page:

Download "Chore-Tronics IDM Board Instruction"

Transcription

1 Chore-Tronics IDM Board Instruction Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety decals immediately. DANGER: Electrical Hazard Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment. March 009

2 Meter and Wiring The pulsed water meters and feed scales require non-shielded 0 gauge twisted pair wire. This wire is available through Chore-Time (part number 408). When routing this wire in the house be sure to keep the wire a minimum of 1" away from line voltage wiring. If there is a need for the sensor wire to cross line voltage wires, cross them at a 90 degree angle to each as shown below. Non Shielded Twisted Pair Wire Line Voltage Wire Connect Meters # through #9 to the IDM board terminals as shown in Figure below using the Twisted Pair Wire. If a water meter not sold by CTB, inc. is used make sure that has a dry contact output connection. DO NOT use a water meter that sends voltage out with every pulse. Note the correct position of the Dip Switches. Meter #5 Meter #4 Meter #3 Meter # Meter Meter #9 Non Shielded Twisted Pair Wire Meter #8 Dip Switches Meter #7 Meter # MT /04

3 Using the blue and brown wires from the s Connect s # through #9 to the IDM board terminals using Twisted Pair Wire (See Figure below). Note the correct position of the Dip Switches. See Manual MT1811 for additional information if needed. #5 #4 #3 # Non-Shielded Twisted Pair Wire Feed Scale #8 #7 # Dip Switches MT /04 Airspeed Meter Wiring The Airspeed Meter connects to the last digital input terminal on the IDM board using a three conductor wire with a shield (See Figure below for Detailed Wiring). See Air Speed Meter manual for installing the Wind Speed Sensor inside the house. Airspeed Meter Black Item Description 1 Air Speed Meter Last Input Terminal 3 Non Shielded Twisted Pair Non-Shielded Twisted Pair Wire Brown Green White Last Input Terminal 3

4 TO C-CENTRAL Model 3 & Model 40 Optional Boards Wiring (Page 1 Continued to facing page TO BACKUP BOX DIP SWITCH # MUST BE IF AT END OF I/O NET 5V 4V EXT GND GROUND WIRE TO I/O BOARD INSTALL IF NOT INCLUDED 1 I/O BOARD FNET -I/O+ NET OS P1 P D1 D GND RH +V RELATIVE HUMIDITY ALARM STATIC PRESSURE S1 S S3 S4 S5 S6 L1 L C NO NC BLK RED RED WIRE GREEN WIRE BLACK WIRE 1 3 DIP SWITCH SETTINGS 5V 4V EXT GND L1 FROM CTROLLER BREAKER L FROM CTROLLER BREAKER FNET -I/O+ NET OS P1 P D1 D GND RH +V SECD I/O BOARD ALARM C NO NC STATIC PRESSURE BLK RED S1 S S3 S4 S5 S6 L1 L 4

5 Model 3 & Model 40 Optional Boards (Page ) Continued from facing page DIP SWITCH SETTINGS IARM BOARD TWISTED PAIR WIRE (PART NO. 408) IDM BOARD DIP SWITCH SETTINGS ` OHM RESISTOR REQUIRED AT EACH END OF I/O NET. 5

6 Model 3/40 nd I/O, IDM and IARM Board Placement (Before April 003) MAIN BOX I/O BOARD IARM Mount the IARM Board To the metal base plate with the white plastic Mounting hardware Supplied with the kit. Mount the Second I/O Board To the metal base plate With the black plastic Mounting Hardware Supplied with the kit. ND I/O BOARD STATIC PRESSURE KIT IDM BOARD Mount the To the metal base plate with the white plastic Mounting hardware Supplied with the kit. Model 3/40 nd I/O, IDM and IARM Board Placement (After April 003) MAIN BOX.5" spacing between I/O Boards I/O Board Place edge of Board at edge of the Backplate ND I/O BOARD STATIC PRESSURE KIT IARM BOARD IDM BOARD Place edge of Board at the edge of the Backplate Approx..5" from bottom of Main Box Approx. 6.5" from bottom of Main Box Mounting Holes: Second I/O: Drill 6-1/4" Holes IARM Board: Drill 6-3/16" Holes : Drill 7-3/16" Holes Approx. " from side of Main Box CTB Inc. P.O. Box 000 Milford, Indiana U.S.A. Phone (574) Fax (877) ctb@ctbinc.com Internet: http//

I/O Expansion Box Installation & Operator s Instruction Manual

I/O Expansion Box Installation & Operator s Instruction Manual I/O Expansion Box Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

FNet Repeater Installation & Operator s Instruction Manual

FNet Repeater Installation & Operator s Instruction Manual FNet Repeater Installation & Operator s Instruction Manual October 2004 CTB Inc. Warranty FNet Repeater CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

C-Collect TM. by CTB Inc. Monitor Box Installation & Operator s Instruction Manual

C-Collect TM. by CTB Inc. Monitor Box Installation & Operator s Instruction Manual C-Collect TM by CTB Inc. Installation & Operator s Instruction Manual October 003 CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new C-Collect TM product manufactured by it to be free from

More information

Bird Scale Control Installation & Operator s Instruction Manual

Bird Scale Control Installation & Operator s Instruction Manual Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new C-Collect product manufactured by it to be free from defects in material or workmanship

More information

Chore-Tronics Mobile Server

Chore-Tronics Mobile Server Chore-Tronics Mobile Server Installation & Operator s Instruction Manual Contact your nearby Chore-Time distributor or representative for additional parts and information. Chore-Time Group A division of

More information

Bird Scale Control Installation & Operator s Instruction Manual

Bird Scale Control Installation & Operator s Instruction Manual Installation & Operator s Instruction Manual March 2006 CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new C-Collect product manufactured by it to be free from defects in material or workmanship

More information

Pit Transition with 24" Fan Installation and Operators Instruction Manual

Pit Transition with 24 Fan Installation and Operators Instruction Manual Pit Transition with 4" Fan Installation and Operators Instruction Manual z Fan and Fan Framing Dimensions Shutter Fan " [8. cm] 6" [9.4 cm] 6-/4" [9. cm] Cone Fan " [5. cm] 4-/6" [88.4 cm] 75-/" [9.8 cm]

More information

Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive. Installation & Operator s Instruction Manual

Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive. Installation & Operator s Instruction Manual Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive Installation & Operator s Instruction Manual July 1998 MV1384B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO

More information

36'' & 48'' E-Z Shutter Fan Installation & Operator s Instruction Manual

36'' & 48'' E-Z Shutter Fan Installation & Operator s Instruction Manual 6'' & 8'' E-Z Shutter Fan Installation & Operator s Instruction Manual MV-8B 8/99 August 999 MVB Chore-Time Warranty 6'' 8'' EZ Shutter Fans Chore-Time Warranty Chore-Time Equipment warrants each new product

More information

Installation and Operation Manual SPC1

Installation and Operation Manual SPC1 Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE

More information

Series Pressure Sensor Instruction Sheet

Series Pressure Sensor Instruction Sheet 2018/05/10 Series ure Sensor Instruction Sheet Thank you very much for choosing Delta DPA series pressure sensor. Please read this instruction sheet carefully before using your DPA. Keep this instruction

More information

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:

More information

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH Man 440 Issue 7 1 1. INTRODUCTION... 3 2. INSTALLATION... 3 2.1 Connection of the Mains Supply... 3 2.2 Connection of the Input to the UPS... 4 2.3

More information

48 Belt Drive Turbo with Tensioner Cone and Grill Fan Installation and Operators Instruction Manual

48 Belt Drive Turbo with Tensioner Cone and Grill Fan Installation and Operators Instruction Manual 8 Belt Drive Turbo with Tensioner Cone and Grill Fan Installation and Operators Instruction Manual Fan Assembly Part Number Fan Sub- Assembly Part Number Fan Interior Color Outlet Voltage Hz Ph HP Motor

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA User's Manual Copyright 2017 V1.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written

More information

RIK-5A Flexible Current Tranformer User's Manual

RIK-5A Flexible Current Tranformer User's Manual RIK-5A Flexible Current Tranformer User's Manual Copyright 2017 V1.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written consent of Accuenergy.

More information

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models L-100, M-100 Series, M-l, M-2, M-3 LESLIE Speaker Models 760, 770, 825 KIT CONTENT Console Connector Assembly 043075

More information

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L MAKING MODERN LIVING POSSIBLE Installation Guide 086L70 www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The

More information

Series Pressure Sensor Instruction Sheet

Series Pressure Sensor Instruction Sheet Series ure Sensor Instruction Sheet Thank you very much for choosing Delta DPB series pressure sensor. Please read this instruction sheet carefully before using your DPB. Keep this instruction sheet handy

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31

More information

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended

More information

HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE

HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE Important: Please read this document in its entirety before removing the Parker VFD drive and installing the Yaskawa V1000 drive.

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

IIM Warwick Court. Williamsburg VA REV 5

IIM Warwick Court. Williamsburg VA REV 5 1 1-757-258-3939 100 Warwick Court Williamsburg VA 23185 REV 5 2 Technical Specification >Accuracy Better than + 1% over a range of 1.5 to 200 amperes with power factor ranging from 1 to 0.5 Approved by

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

Installation & Operator s Instruction Manual

Installation & Operator s Instruction Manual Chore-Tronics 3 Control Installation & Operator s Instruction Manual February 2012 1 Chore-Time Warranty Chore-Time Warranty Chore-Time Equipment ( Chore-Time ) warrants each new Chore-Time product manufactured

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions. Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64

More information

Panduit Basic Rack PDU

Panduit Basic Rack PDU Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any

More information

Installation Instructions

Installation Instructions Installation Instructions Single Enthalpy Sensor Application AXB078ENT Differential Enthalpy Sensor Application (Part # AXB078ENT and DNENTDIF004A00) FOR ROOFTOP ECONOMIZERS EQUIPPED WITH HONEYWELL W7212

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

Installation and Operation Manual DPC1

Installation and Operation Manual DPC1 Installation and Operation Manual DPC1 BIA-DPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 6-7 QUICK

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

OilCop Component Wiring Installation Manual

OilCop Component Wiring Installation Manual OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:

More information

ORB TM 4-20 ma Input Box Installation & Operation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL AC Panel Transient Voltage Surge Suppressors INTRODUCTION This document explains how to install the Powerware TVSS ZoneSentinel AC Panel

More information

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1 User Manual 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation...

More information

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Sensor - ModBus Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read

More information

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-920, IA001723 Nov. 2005 OPERATION MANUAL High Voltage Digitalmeter 149-30A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

Installation Instructions

Installation Instructions Installation Instructions Single Enthalpy Sensor Application AXB078ENT Differential Enthalpy Sensor Application (Part # AXB078ENT and DNENTDIF004A00) FOR ROOFTOP ECONOMIZERS EQUIPPED WITH HONEYWELL W7212

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for

More information

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015 PT230 PONTOON THRUSTER (PATENT PENDING) INSTALLATION MANUAL VOLUME 1.2, JUNE 2015 Sideshift Inc. 130 Industrial Ave, Unit 303, Carleton Place, ON, Canada K7C 3T2 1.877.325.4787 +613.686.6011 INFO@SIDESHIFT.COM

More information

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death. Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Adaptor Model No. CZ-CFUNC1U For your safety Read the following instructions carefully, and carry out secure installation and electrical work. The precautions given in this manual

More information

MT400 MOTION CONTROLLER

MT400 MOTION CONTROLLER MT400 MOTION CONTROLLER INSTALLATION & TECHNICAL MANUAL 5/30/2012 417 Wards Corner Road Loveland, OH 45140 800.659.8250 FAX: 513.398.2536 www.maxitronic.com Table of Contents Page 3: Page 4: Page 5: Page

More information

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology Building Wash User Guide Advanced LED Technology TABLE OF CONTENTS 1. Safety Instruction 2. Technical Specification 3. Change Beam Angle 4. Main Function 5. How To Control The Unit 6. Troubleshooting 7.

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

36" & 48" Shutter Box Fan Installation & Operator s Instruction Manual

36 & 48 Shutter Box Fan Installation & Operator s Instruction Manual 6" & 8" Shutter Box Fan Installation & Operator s Instruction Manual Mv666-0 0/0 Mv666-005 /00 October 009 Chore-Time Warranty 6" & 8" Shutter Box Fan Chore-Time Warranty Chore-Time Egg Production Systems

More information

Panduit Basic Rack PDU with Local Meter

Panduit Basic Rack PDU with Local Meter Panduit Basic Rack PDU with Local Meter User Manual Release 1.0 Issue 1.0 Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted

More information

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio

More information

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8 User Manual 2.2KW/7.5KW/11KW Solar Inverter for Water Pump Version: 1.8 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Operating Instructions Differential Pressure Transducer PS27

Operating Instructions Differential Pressure Transducer PS27 Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com

More information

G5 PDU Installation Guide

G5 PDU Installation Guide G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form

More information

Ground Fault Protection. Instruction Manual

Ground Fault Protection. Instruction Manual Ground Fault Protection DSP OHMNI Accessory: DSP-CA(S) Cable Adapter Instruction Manual 7615 Kimbel Street, Mississauga, Ontario Canada L5S 1A8 Tel: (905)673-1553 Fax: (905)673-8472 Toll Free: 1-888-RESISTR

More information

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

-Verify that supply wiring voltage matches power supply voltage by comparing it with power supply label.

-Verify that supply wiring voltage matches power supply voltage by comparing it with power supply label. WARNING! RISK OF FIRE OR ELECTRICAL SHOCK Disconnect power before installing or servicing. WARNING: Risk of fire or electrical shock. Luminaire wiring, power supply, or other electrical parts may be damaged

More information

Assembly Instructions scancontrol 2700/2750 (500)

Assembly Instructions scancontrol 2700/2750 (500) Assembly Instructions scancontrol 2700/2750 (500) 1. Warnings Connect the power supply and the display-/output device in accordance with the safety regulations for electrical equipment. The power supply

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Adapter Kit - QSI Electronics to TM Meter Installation Instructions Adapter Kit - QSI Electronics to TM Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features Fully Adjustable, Multiple Viewing Angle Smart Camera. High Resolution, 1/2 CMOS Color Camera

More information

Always "On" UPS Systems Inc. USER MANUAL

Always On UPS Systems Inc. USER MANUAL Always "On" UPS Systems Inc. SMART HOME PROTECTOR USER MANUAL Bldg 1-150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext. 451, Fax: (250) 491-9775, Email: sales@alwaysonups.com Web

More information

Platinum Plus and Platinum Junior Controller

Platinum Plus and Platinum Junior Controller Platinum Plus and Platinum Junior Controller Version 2.83 Installation Manual P/N: 110017 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or

More information

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition ipf opti-check 1070 53 x 99.5 x 38mm camera sensor operating distance variable C-mount for lenses integrated flash controller short set-up times because of up to 255 check programs with up to 32 feature

More information

Digital encoder interface module 5/12/24 V DANGER

Digital encoder interface module 5/12/24 V DANGER NHA807300 Digital encoder interface module 5//4 V VW3A340 DANGER HAZARD F ELECTRIC SHCK, EXPLSIN, R ARC FLASH nly appropriately trained persons who are familiar with and understand the contents of this

More information

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series PRODUCT NEWS Product Discontinuation Notices July 4, 2011 Presence Detection Sensors No. 2011195E Discontinuation Notice of Safety Laser Scanner Product Discontinuation Safety laser scanner Accessories

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS LRC0 8X0A Relay Control Panel BACnet MS/TP Enabled INSTALLATI INSTRUCTIS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS!

More information

Installation Instructions & User Manual

Installation Instructions & User Manual Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

INSTALLATION AND OPERATING INSTRUCTIONS FOR. Serial Control Board SCB-100

INSTALLATION AND OPERATING INSTRUCTIONS FOR. Serial Control Board SCB-100 INSTALLATION AND OPERATING INSTRUCTIONS FOR Serial Control Board SCB-100 Important Safety Instructions When using your video equipment, basic safety precautions should always be followed, including the

More information

MS-7000: SuperStar Reader

MS-7000: SuperStar Reader The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi

More information

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

What s in the Box? REAR VIEW SAFETY

What s in the Box? REAR VIEW SAFETY TM 1 What s in the Box? 1 Full HD Color Infra-red Weather Proof Camera 1 Full HD 7" TFT LCD Color Monitor w/monitor Mount 1 Power Harness 1 66 Camera Cable 1 Power Connection Wire 1 Screw Kit for installation

More information

VBAR 270. User Manual. Version 1.2

VBAR 270. User Manual. Version 1.2 VBAR 270 User Manual Version 1.2 VBAR 270 User Manual Page 1of 19 Introduction Thank you for purchasing VBAR 270. VBAR 270 is a LED light fixture for professional use. Using the RGB color mixing technology

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX Instruction Bulletin 63249-500-04A3 07/2010 Fiber Optic Switch Packs SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION SLSPSP101 Single Input Switch Pack SLSPSP102 Dual Input Switch Pack The

More information

LED Slimline PAR RGBW 7x8W

LED Slimline PAR RGBW 7x8W VIS0495.3 LED Slimline PAR RGBW 7x8W User Manual KEEP THIS MANUAL FOR FURTHER NEEDS Key Features: 7 x RGBW QUAD 8W LED IP65 Weatherproof Die-Cast Housing Slimline, Compact & Stylish Design 45 Beam Angle

More information

MS-5000: MiniStar Reader

MS-5000: MiniStar Reader The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also

More information

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions Adapter Kit - QSI Electronics to G2 Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

Power & Communication Cables

Power & Communication Cables Power & Communication Cables CBLSM-M & CBLSM-X series is the main power and communications cable consisting of a 7W main motor connector split out to a pre-wired RS- DB- connector to plug directly into

More information

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors: TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Configuration 6. DMX512 Connections 7. How to Set the Unit 8. Troubleshooting

More information

N-E Color Par 64 USER MANUAL

N-E Color Par 64 USER MANUAL N-E Color Par 64 USER MANUAL Table of Contents Safety Information. 3 Specifications.. 4 Main Power Connection.. 5 DMX-512 Connection...... 5 Rigging the Fixture.9 DMX Profile... 6 Main Control Menu...

More information

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors H765B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors APPLICATION The H765B, H7635B, H7655B Duct-Mount and H7635C Outdoor-Mount Humidity/Temperature Sensors are universal Relative

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information